Public Works Department Tender
BidAssist is a very user-friendly website that lets us explore new opportunities which further helps in the growth of the business. We can get any information regarding any e-tender the Tripura government has posted on its website in a very hassle-free manner. BidAssist is designed in such a manner so as to provide information on all government tenders at one place without any inconvenience.
Public Works Department - PWD Tender
Civil And Construction
Road Construction
Eprocure
Opening Date27 Aug 2024
Closing Date20 Sep 2024
Tender Amount₹ 84,97,564
Costs
EMD
₹ 1,69,951Document Cost
₹ 4,000Tender Fee
Refer Documents
Summary
Mtc. Of Dharmanagar Maheshsmriti Road With Paver Block Road (l 0.45km)
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_CEPWD_51707_1Tender No
06/SE(1)/KGT/2024-25Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://https://pwd.tripura.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supplying, fitting & placing Thermo-Mechanically treated bar/ Cold twisted deformed steel bar reinforcement in foundation complete as per drawings & MoRT&H technical specifications Clauses 1600.
4.45
405566
91240.9
.80 mm thick factory made c.c. interlocking paver block of M-35 Grade. Providing and laying factory made chamfered edge Cement Concrete paver blocks of required strength, thickness & size / shape, made by table vibratory method to attain superior smooth finish using PU or equivalent moulds, laid in required grey colour & pattern over 50 mm thick compacted bed of sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand in footpath, parks, lawns, drive ways or light traffic parking etc. all complete as per specifications & approval/ direction of the Engineer -in-Charge: (a) 80 mm thick c.c. paver block of M-35 grade with approved colour, design and pattern.
2700
4190400
1552
Granular Sub-base with Well Graded Material (Table 400.1) By Mix in Place Method. Construction of granular sub-base by providing well graded material spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per MoRT&H Technical Specification Clause 401. (I) For Grading I Material.
112.5
723769
6433.5
Water Bound Macadam Sub-Base / Base
(ii) WBM Grading 2. Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/ binding materials to fill up the interstices of coarse aggregate, watering and compacting to the required density 'Grading 2' as per MoRD Technical Specification Clause 405. (A) By Manual Means.
202.5
1684537
8318.7
Excavation for Structures.
Earthwork in excavation for structures as per drawing and MoRT&H technical specifications Clause 304 including setting out, construction of shoring & bracing, removal of stumps & other deleterious material and disposal upto a
lead of 50 m, dressing of sides & bottom and backfilling in trenches with excavated suitable material.
Ordinary Soil. A. By Manual Means Upto 3 m depth
56
25659
458.2
Sand Filling.
Sand Filling in foundation trenches as per drawing & MoRT&H technical specification clause 304.
3.23
3767
1168
PCC 1:3:6 in Foundation. Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days as per drawings & MoRT&H technical specifications Clauses 2100. (including centering, shuttering, staging etc. but excluding reinforcement) .
3.23
30835
9561.1
Plain / Reinforced cement concrete in open foundation as per drawings & MoRT&H technical specifications Clauses 1500, 1700, 2100. (including centering, shuttering, staging etc. but excluding reinforcement).
RCC Grade M 25 Case - I : Using Concrete Mixer.
7.25
81865
11291.7
Plain/reinforced cement concrete in substructure complete including formwork as per drawings & MoRD technical specification Clauses 802, 804, 805, 806, 807, 900, 1202 & 1204. (including centering, shuttering, staging etc. But excluding reinforcement).
(VI) R.C.C grade M-25 .(i) upto 5 m height.
10
123000
12300
Supplying, fitting & placing Thermo-Mechanically treated bar/ Cold twisted deformed steel bar in substructure complete as per drawings & MoRD technical specification Clauses 1002, 1005, 1010 and 1202.
1.2
109780
91483.2
Providing & laying reinforced cement concrete in superstructure as per drawings & MoRD technical specifications Clauses 800, 900, 1205.4 & 1205.5 (including centering, shuttering, staging etc. but excluding reinforcement). (VI) R.C.C grade M-25.
(i) upto 5 m height.
5.31
71046
13372.2
Supplying, fitting, & placing Thermo-Mechanically treated bar/ Cold twisted deformed steel bar reinforcement in superstructure complete as per drawing & MoRD technical specifications Clauses 1002, 1010 & 1202.
0.64
59484
93234.9
Providing weep holes in brick masonry/ stone masonry, plain/ reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe or uPVC pipe (110 mm OD of 6.0 Kg/cm2 pressure) extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and MoRT&H technical specification clauses 2706, 2200.
4
1571
392.7
.Providing and laying of Filter media with granular materials/ stone crushed ggregates satisfying the requirements laid down in clause 2504.2.2. of MoRT&H specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and clause 710.1.4 of IRC:78 & MoRT&H technical specification Clause 2200.
5.76
27176
4718.1
.Backfilling behind abutment, wing wall & return wall complete as per drawings, clause 710.1.4 of IRC:78 & MoRT&H technical specification Clause 2200.
ii) Sandy material.
24
38210
1592.1
Plastering with Cement Mortar (1 : 4), 15 mm thick on brickwork in substructure as per MoRD technical specification Clause 613.4.
3.75
837
223.2
Providing pressure relief pipes 100 mm dia in bottom slab of box cell on a filter media base of 500 mm x 500 mm as per drawing & MoRD technical specification Clause 1205.5.7.
4
6098
1524.4
Construction of RCC railing of M 30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequate space between vertical post for expansion, complete as per approved drawings (No. SD / 202), including all formworks required and MoRT&H Technical Specification Clause 2703, 1500, 1600, 1700. (including centering, shuttering, staging etc. and reinforcement).
5
13650
2729.9
Providing and placing in position drainage Spouts complete as per drawing (SD/205) and MoRT&H Technical Specification Clause 515, 2705.
4
33681
8420.3
Evaluation Notes How It Works ?