Public Works Department Tender
BidAssist is a very user-friendly website that lets us explore new opportunities which further helps in the growth of the business. We can get any information regarding any e-tender the Tripura government has posted on its website in a very hassle-free manner. BidAssist is designed in such a manner so as to provide information on all government tenders at one place without any inconvenience.
Costs
EMD
₹ 99,644Document Cost
₹ 1,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_CEPWD_57819_1Tender No
23_DNIeT_SEIV_PWD_202425Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://https://pwd.tripura.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Supply & erection duct dampers (Manual GI material) complete as per direction of the Engineer in charge:--
12
-
-
... More
Providing ,installation & commissioning of horizontal floor mounted/ceiling suspended AHU with GI sheet metal cabinet type in double skin construction fabricated from extruded aluminium profile frame (thermal break) structure. The inner skin 0.6 mm thick GI Plain & Outer skin 0.6 mm thick GI sheets pre coated/powder coated construction with 45 mm thick CFC free PUF insulation(Density 40-42kg/cubic mtr.) with internal coving and in thermal break construction complete with following section with single mixing chamber with Pre-filter & Fine filter section, DX type cooling coil. 20 Micron filter-HDPE washable type, coil area 4.40 sq. ft. 6 coil rows,3/8'' ODx0.41mm thick seamless copper tubes,0.15 mm thick x 12-13 aluminium fins/inch,18 G.S.S drain pan with 10 mm thick insulation on outside, provided with return air & fresh air opening,3 kw GI electric tubular heater,3 phase,2 pole,415 v(+-10%),IP 55,TEFC sq.case induction Motor as per direction of the engineer-in-charge.( Make: ETHOS/Edgetech/Zeco) compatible with VRF Outdoor unit) i)Capacity:- 7.5 TR, 3000 CFM (Floor Mounted/ceiling suspended AHU) with 20% fresh Air
2
-
-
... More
Providing , Installation & commissioning of Variable Refrigerant Flow (VRF) System Outdoor units of AC machines minimum capacity of 10 HP each Top discharge, Modular type only cool, next generation VRF, each outdoor unit comprises of 100% inverter Driven Hermetically sealed Scroll Compressors , air cooled condenser with protective coated fins heat exchangement corrosion fin factory coated propeller type fan with motor , specially designed ODUs with refrigerant cooled heat sink , non stop working at 56 degree C, with R410A or equivalent Refrigerant , working on 3 phase AC range of 380 volt to 420 (±5%)Volt, 50Hz , the outdoor unit should contain error code LED display for ease of operation, auto addressing setting refrigerant cool PCB, Electronic expansion Valve, microprocessor controller, VRF unit should be compatible with AHU/TFA etc. complete as per direction of the Engineer in charge
3
-
-
... More
Providing , Installation, Testing & commissioning of Variable Refrigerant Flow (VRF) System type Indore unit comprising of Copper coil section, filter section, micro processor type PCB , the unit shall be ceiling suspended type and complete with all standard accessories etc. complete as per direction of the Engineer in charge. VRF four way Cassette unit Capacity minimum 2 TR
4
-
-
... More
Providing & Installation of Remote Controller Compatible of VRF indoor Unit , Cordless controller etc. complete as per direction of the Engineer in charge. VRF High Wall unit Capacity minimum 1.5 TR
4
-
-
... More
Providing & fitting fixing of copper individual Refnet Y distribution joint IDU etc. complete as per direction of the Engineer in charge
4
-
-
... More
Providing & fitting fixing of copper individual Refnet Y distribution joint ODU etc. complete as per direction of the Engineer in charge
2
-
-
... More
Supply, installation, testing & commissioning of in/c vaccumiazation and Nitogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRF/VRV system, complete with fittings with suitable adjustable ring type hanger supports, joining/ brazing in/c accessories insulated with XLPE Class O tubular insulation / with Classs O clossed cell elastemetic nitrile rubber tubular sleeves sections of specified thickness as below for suction and liquid lines, all accessories as per specification etc. as required complete as per direction of the Engineer in charge 6.4 mm dia (OD) (Hard Drawn) with tube thickness 1.2 mm with 19 mm thick insulation
15
-
-
... More
9.5 mm dia (OD) (Hard Drawn) with tube thickness 1.2 mm with 19 mm thick insulation or its nearest dia.
20
-
-
... More
12.7 mm dia (OD) (Hard Drawn) with tube thickness 1.2 mm with 19 mm thick insulation or its nearest dia.
20
-
-
... More
15.86 mm dia (OD) (Hard Drawn) with tube thickness 1.2 mm with 19 mm thick insulation or its nearest dia.
60
-
-
... More
19 mm dia (OD) (Hard Drawn) with tube thickness 1.2 mm with 19 mm thick insulation or its nearest dia.
60
-
-
... More
22.2 mm dia (OD) (Hard Drawn) with tube thickness 1.2 mm with 19 mm thick insulation or its nearest dia.
40
-
-
... More
28.58 mm dia (OD) (Hard Drawn) with tube thickness 1.2 mm with 19 mm thick insulation or its nearest dia.
100
-
-
... More
34.9 mm dia (OD) (Hard Drawn) with tube thickness 1.2 mm with 19 mm thick insulation or its nearest dia..
30
-
-
... More
41.3 mm dia (OD) (Hard Drawn) with tube thickness 1.2 mm with 19 mm thick insulation or its nearest dia.
20
-
-
... More
Supply, installation testing & commissioning of rigid PVC pipe (for drainage of water from IDU) complete with fittings, supports as per specification and duly insulated with 6 mm thick closed cell Nitrale Rubber insulation ) 25 mm with 6 mm thick Nitrale Rubber insulation
80
-
-
... More
32 mm with 6 mm thick Nitrale Rubber insulation
70
-
-
... More
Supply & laying of Copper conductor scheduled flexible communication cabling between ODU and IDU as per OEM specification (VRF) cable shall be laying through hard PVC conduit pipe etc complete as per direction of the Engineer in charge
150
-
-
... More
Supply & fitting fixing of G.I. Cable Tray for laying of copper pipe support along with fittings as per required size 150mm etc complete as per direction of the Engineer in charge
20
-
-
... More
Supply & filling of First charge of refrigerant R410 A etc complete as per direction of the Engineer in charge
50
-
-
... More
Providing & connecting Electric control cables between indoor & outdoor, Machine room Supply point to indoor machine suitable cable for 3phase line in/c Neutral etc complete as per direction of the Engineer in charge
55
-
-
... More
Providing & installation Outdoor structure or CC Pedestal complete as per direction of the Engineer in charge
5
-
-
... More
Cutting of existing ceiling for laying of refrigerant pipe in different places of the building and repairing the same by gypsum board, aluminium channel etc. in/c painting as same to same of existing ceiling complete as per direction of the Engineer in charge
6
-
-
... More
Supply of AHU Kit for Connecting of AHU with MRV/VRF Outdoor AC as per design.
2
-
-
... More
Supply & erection of GI Ducting complete as per direction of the Engineer in charge:- 22G GSS Sheet
25
-
-
... More
Supply & erection of GI Ducting complete as per direction of the Engineer in charge:- 24G GSS Sheet
45
-
-
... More
Supply & erection of inside Duct acoustic insulation with 10 mm thick (Class -1 Accosound) Nitrale with perforated aluminium sheet complete as per direction of the Engineer in charge.
15
-
-
... More
Supply & erection of Thermal insulation with 13 mm thick Nitrale with aluminum foel complete as per direction of the Engineer in charge.
70
-
-
... More
Supply & erection Canvas connection complete as per direction of the Engineer in charge.
2
-
-
... More
Providing & Installation Grilles/Diffusers complete as per direction of the Engineer in charge:-
5.5
-
-
... More
Supply & erection duct dampers (Manual GI material) complete as per direction of the Engineer in charge:-
2.3
-
-
... More
Providing in/c testing and commissioning (except Installation) of Split type Hi-wall 2.00 TR (6,000 Kcal/ hr.) A.C. Machine with Inverter Compressor technology operating on non-CFC refrigerant (R-410A/R-32/equivalent refrigerants) suitable for wall mounting conforming to IS:1391 (Part-II) specification (Evaporator & condenser must have copper pipe), suitable for operation on 230 volt +- 10%, not less than 3 (Three) Star rating (2019 Standard), 50Hz, Single Phase AC Supply capable of performing a) Cooling, b) Dehumidifying, c) Air Circulation, d) Filtering, as per direction of the Engineer-in-Charge
10
-
-
... More
Standard installation of 1.5 TR/2.00 TR capacity Hi-Wall Split type type Air Conditioner in/c repairing of drilled wall by cement mortar, painting in/c necessary insulation, clamping and warping by white masking tape of copper pipes, and also providing electrical 3 pin 16 amp Top for connection in socket & necessary scaffolding etc. complete as per direction of the Engineer-in-Charge.
10
-
-
... More
Supply and installation of additional length of copper pipe of 5/8'' and 1/4'' diameter or suitable diameter for suction and liquid line in a set and wrapping of copper pipes between indoor and outdoor unit (1.50 TR & 2.00 TR AC) beyond the standard length of pipe as per direction of the Engineer-in-Charge.
72
-
-
... More
Fabrication of M.S. platform for placement of condensing unit by using M.S. angle of (50x50x5) mm size base plate, nuts & bolts or cradle of suitable sizes i/c painting, fitting, fixing grouting by cement mixer as per direction of the Engineer-in-Charge.
10
-
-
... More
Providing hard PVC pipe of good quality of at least 25 mm diameter including necessary clamping and fitting for draining of condensate water from indoor unit as per direction of the Engineer-in-Charge.
70
-
-
... More
Providing and connecting Electric Control cables between indoor unit and outdoor unit beyond stand quantity kit. 3C X 2.5 Square mm Copper Cable.
72
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%