Public Works Department Tender
BidAssist is a very user-friendly website that lets us explore new opportunities which further helps in the growth of the business. We can get any information regarding any e-tender the Tripura government has posted on its website in a very hassle-free manner. BidAssist is designed in such a manner so as to provide information on all government tenders at one place without any inconvenience.
Public Works Department - PWD Tender
Civil And Construction
Eprocure
Opening Date11 Jun 2024
Closing Date18 Jun 2024
Tender AmountRefer Documents
Costs
EMD
₹ 96,621Document Cost
₹ 1,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_CEDWS_49300_1Tender No
72/EE/DWS/BLG/2024-25Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://https://pwd.tripura.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering -
-All work upto plinth level:
-
-
-
1:2:4 ( 1 Cement: 2 fine sand : 4 graded well burnt brick aggregate 20 mm nominal size)
7.88
84598
10742.6
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement- All work upto plinth level:
-
-
-
1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size)
89.93
1085833
12073.8
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more
13489.88
1401598
103.9
Centering shuttering including struttings, propping etc. and removal of form work for:
-
-
-
Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. using shuttering ply
633.15
314106
496.1
12 mm cement plaster of mix i).In cement mortar 1 : 4 ( 1 cement : 4 fine sand )
2334.15
523316
224.2
Neat cement punning.
2334.15
132580
56.8
Excavating trenches of required width for pipes, cables etc. in/c excavation for sockets and dressing of sides, where required ramming of bottom, depth up to 1500 mm ( Slope 1 in 200) in/c getting out the excavated soil and backfilling of soil as required after laying of pipe line, in layer not exceeding 200mm in depth in/c consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed with all required lead as per Chapter-2 of CPWD specification & direction of the Engineer-in-Charge.
-
-
-
A).For UPVC pipes in new work
a). in all kinds of soil i) For Pipes not exceeding 90 mm dia
3300
289080
87.6
A).For UPVC pipes in new work
a). in all kinds of soil i) For pipes exceeding 90 mm dia but not
exceeding 300 mm dia
100
10640
106.4
Providing and fixing G.I. pipes medium class as per IS : 1239 with latest amendment complete with G.I. fittings including trenching and refilling, cutting and making good the walls etc. complete as per CPWD specification and direction of the Engineer- in - charge. A) External works
-
-
-
i. 15 mm dia. nominal bore
630
124425
197.5
Providing, fixing and laying rigid UPVC pipes conforming to IS :4985 jointing with couplers, of same class conforming to IS : 10124 ( Pt-II ) with solvent cement conforming to IS : 14182 including testing of joints complete ( but excluding the cost of specials like bend, tees etc. which will be paid separately ) as per CPWD specification and direction of the Engineer - in - charge.
-
-
-
A. Class - 3 ( working pressure 6.0 kg / cm2)
-
-
-
i. 40 mm OD
100
8980
89.8
i. 90 mm OD
50
13570
271.4
i. 110 mm OD
50
18605
372.1
i. 140 mm OD
50
30640
612.8
Providing and laying of flexible PVC pipe (Conforming to IS:7634) complete as per specification and direction of the Engineer-in-charge (cost of earth work and fittings will be paid separately). i. 15 mm dia.
3150
180495
57.3
Providing and fixing G.I. bend / elbow in the pipe line in/c testing of joints complete as per CPWD specification and direction the Engineer-in-charge. i) 15 mm Dia
1260
132048
104.8
Providing and fixing G.I. union as per CPWD specification and direction of the Engineer-in-charge. i) i)15 mm Dia
630
82530
131
Providing and fixing G.I. socket as per CPWD specification and direction of the Engineer-in-charge. i)15 mm Dia
1260
99036
78.6
Providing and fitting fixing PVC / plastic bib cock conforming to IS : 9763 in hydrant points at different location as per specification & direction of the Engineer-in-charge. (i) 15mm dia PVC/ Plastic bib cock
630
75222
119.4
Providing and fixing G.I. nipple of medium class as per CPWD Specification and direction of the Engineer-in-charge
-
-
-
i) 15 mm dia 75 mm long
630
40383
64.1
ii) 15 mm dia 150 mm long
630
43218
68.6
Providing, fixing and laying fabricated UPVC bend of required degree conforming to IS : 10124 ( part 8 / 9 / 10 / 11 / 12 / 13 ) with solvent cement conforming to IS : 14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge.
-
-
-
iii. 90 mm dia.
2
597
298.7
iv. 110 mm dia
2
713
356.4
v. 140 mm dia
2
934
466.8
Providing, fixing and laying fabricated UPVC straight reducer conforming to IS : 10124 ( Part 3 ) with solvent cement conforming to IS : 14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge.
-
-
-
i. 50 x 40 mm dia
2
344
172
ii. 110 x 90 mm dia
2
642
321.1
iii. 140 x 110 mm dia
2
854
426.8
iv. 140 x 90 mm dial
2
791
395.7
Providing, fixing and laying fabricated UPVC equal tee conforming to IS : 10124 ( Part 5 ) with solvent cement conforming to IS :14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge.
-
-
-
i. 40 x 40 mm dia
2
464
232
ii. 50 x 50 mm dia
2
525
262.5
iv. 90 x 90 mm dia
2
704
352.2
v. 110 x 110 mm dia
2
1161
580.4
vi. 140 x 140 mm dia
2
1636
818
Washing & removal of deposited iron sludge & any other foregn materials from inside the existing wter distribution pipe line (PVC) using UPVC coil pipe (Washing rod fitted with iron brush in/c excavation trenches up to required depth with cutting of C.I/D.I/G.I pipes at a lenght of every 55 mtr interval or post there of and jointing of pipes and special as required refilling trenches with available excavated earth etc. complete as per direction of the Egnineer-in-charge (Rate in/c of making PVC couplers, Cost of cement solvent PVC pipe for making PVC couplers will be issued by the department at free of cost).
-
-
-
i. 90 mm dia.
20
82
4.1
ii. 110 mm Dia
20
96
4.79
iii. 140 mm Dia.
20
102
5.1
Charges for repairing of leakage in UPVC / HDPE pipe line with PVC coupler and solvent cement etc. including necessary earth excavation, backfilling of soil as required after laying of pipeline, in layers not exceeding 200 mm in depth including consolidating each deposited layer by ramming, watering etc. complete as per specification and direction of the Engineer-in-charge
-
-
-
i. 90 mm OD
10
5581
558.1
ii. 110 mm OD
10
6232
623.2
iii. 140 mm OD
10
6891
689.1
Charges for dismantling PVC / HDPE pipe after necessary excavation of earth including washing and stacking of pipes properly at site with all leads and lifts and backfilling of soil as required after laying of pipeline, in layers not exceeding 200 mm in depth including consolidating each deposited layer by ramming, watering etc. complete as per specification & direction of the Engineer-in-charge.
-
-
-
90 mm dia
10
3368
336.8
110 mm dia
10
3600
360
140 mm dia
10
3948
394.8
Charges for fixing and laying rigid UPVC pipes jointing with couplers, solvent cement including testing of joints complete ( excluding the cost of pipes, couplers, solvent cement which are to be issued from the department free of cost and specials like bend, tees etc. which will be paid separately) as per CPWD specification and direction of the Engineer - in - charge.
-
-
-
90 mm dia
10
266
26.6
110 mm dia
10
323
32.3
140 mm dia
10
413
41.3
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements