Transmission Corporation Of Andhra Pradesh Limited Tender

... More
For getting the details of etenders, if you are looking for information about them from the cumbersome government websites but are tired of doing so, Bidassist comes up with a one stop solution. It collates every Eproc telangana tender on Bidassist. One can approach it for the bidding process, registration process, etc., are explained below.

Transmission Corporation Of Andhra Pradesh Limited - APTRANSCO Tender

Works
Electrical and Electronics
Electrical Works
Opening Date28 Feb 2025
Closing Soon7 Apr 2025
Tender Amount₹ 23,38,181 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Repairs to control room at 132 kV Manoharabad SS;Laying of Reinforced Cement Concrete (RCC) M25 Grade with standard mix design as per IS 10262:1982 containing minimum cement content 380 kgs, Coarse aggregate 20mm size graded machine crushed hard granite metal and fine aggregate of zone - II as per the mix design approved by the departmental from approved quarry including cost and conveyance of all materials like cement, fine aggregate, coarse aggregate, water etc., to site and including all operational, incidental and labour charges such as volumetric batching, machine mixing, laying concrete, curing and centering, etc.,complete but excluding cost of steel and its fabrication charges for finished item of work as directed by the Engineer in charge. Centering should be with steel scaffolded pipes, jack props, wallers, foot plates, brackets, steel centering plates etc. complete.

3

8687

26062.68

... More
Repairs to control room at 132 kV Manoharabad SS;Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) (Fe 500/ 500D/550D) grade as per IS 1786-1979) of TISCO/ SAIL/ VSP/Jindal make, different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes, placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying etc., complete for finished item of work in all floors as per the directions of the Engineer-in-charge. (SWITCHYARD WORK)

0.55

70162

38589.17

... More
Repairs to control room at 132 kV Manoharabad SS;Plastering to Uneven surfaces of RR /CR, PCC with CM(1:5) 20mm. thick including cost & conveyance of all materials, labour charges, leads, lifts and curing complete as per the directions of the Engineer in charge for the finished item of work.

15

238

3577.8

... More
Repairs to control room at 132 kV Manoharabad SS;Laying of Plain Cement concrete (PCC) - Nominal Mix (1:3:6) with 20mm graded HBG metal over RR wall with necessary form work including cost and conveyance of all materials, labour charges, curing and water charges, tools and tackles, all leads & lifts etc., complete for finished item of work as per directions of the Engineer-in-charge. (IS-456)

1

5539

5539.96

... More
Repairs to control room at 132 kV Manoharabad SS;Construction of RR Masonry with CM (1:6) using hard CRS , rough granite stone and bond stones (0.16 cum) including cost and conveyance of all matreials., labour charges, water lead , curing, all leads and lifts etc., complete for finished item of work as per directions of the Engineer-in-charge.

6

4103

24620.04

... More
Repairs to control room at 132 kV Manoharabad SS;Laying of Cement Concrete (1:4:8) mix using 40mm size HBG Machine crushed metal for foundations including cost and conveyance of all materials at all leads and lifts, ramming, consolidating, curing etc,complete. for finished item of work as per directions of the Engineer-in-charge.

2

4440

8880.36

... More
Repairs to control room at 132 kV Manoharabad SS;Earthwork excavation in all types of soils (upto stone matrix) which can be excavated in combination of mechanically and manually with pick axe and crow bars and do not require blasting in all conditions such as dry, wet, slushy etc., covering initial lead and lift etc., and backfilling the foundations (after laying foundations) with excavated earth including watering, compacting as per standard specification and disposing of surplus earth within site (up to 1KM lead) complete as per directions of Engineer in charge at site for finished item of work.

16

159

2552.8

... More
Repairs to control room at 132 kV Manoharabad SS;Supply and Laying of P.V.C casing and caping (Modi make or equivalent )(ISI MARK) with double locking arrangments with groover trunking of size not below 12.5mm height for the following sizes with all accessories, duly sealed at points and erected on Wall / Ceiling including cost of all materials and labour charges complete for the finished item of work as directed by the Engineer-in-charge. 32mm x 12.5 mm height

30

77

2328

... More
Repairs to control room at 132 kV Manoharabad SS;Supply and Laying of P.V.C casing and caping (Modi make or equivalent )(ISI MARK) with double locking arrangments with groover trunking of size not below 12.5mm height for the following sizes with all accessories, duly sealed at points and erected on Wall / Ceiling including cost of all materials and labour charges complete for the finished item of work as directed by the Engineer-in-charge. 25mm x 12.5mm height

100

71

7108

... More
Repairs to control room at 132 kV Manoharabad SS;Supply and Laying of P.V.C casing and caping (Modi make or equivalent )(ISI MARK) with double locking arrangments with groover trunking of size not below 12.5mm height for the following sizes with all accessories, duly sealed at points and erected on Wall / Ceiling including cost of all materials and labour charges complete for the finished item of work as directed by the Engineer-in-charge. 19mm / 20mm x 12.5 mm height

50

65

3282

... More
Repairs to control room at 132 kV Manoharabad SS;Run 2 of 36/0.30 (2.5 Sqmm) FRLSH / HFFR PVC insulated 1100V grade as per IS:694 / 2010, IS 17048 specification for Copper cable (Makes: Finolex / RR kabel / Havells /Polycab / Beljin (HFFR) / Finecab Gold (HFFR) / GM (HFFR) / Gold Medal (HFFR) / Million(HFFR) /KEI (HFFR) / V-Guard (HFFR)) in existing pipe for Mains from Distribution board to 15Amps 3 pin Power Plug including giving connections and labour charges and cost of materials complete as directed by the Engineer in charge for the finished item of work at all levels of building.

200

107

21552

... More
Repairs to control room at 132 kV Manoharabad SS;Supply and fixing of HID / batten holder / slanting holder (Wipro/G.E./Phillips) in lieu of ceiling rose of light point complete with all connections and all labour charges with 9 W LED lamp (Phillips / OSRAM / Crompton / Eveready / Bajaj / Havells / Pharox / Halonix / Greenlites / IB LED/ Jaquar / C&S / GM / Gold Medal / Million / Syska) (for new installation).

5

243

1215.45

... More
Repairs to control room at 132 kV Manoharabad SS;Wiring with 2 runs of 22/0.30(1.5 M2m) FRLSH / HFFR PVC insulated 1100V grade as per IS:694 / 2010, IS 17048 specification for Copper cable (Makes: Finolex / RR kabel / Havells /Polycab / Beljin (HFFR) / Finecab Gold (HFFR) / GM (HFFR) / Gold Medal (HFFR) / Million(HFFR) /KEI (HFFR) / V-Guard (HFFR)) in existing pipe with 6A Modular switch (Legrand Lyncus / GM Four Five/ Million/ Gold Medal Curve/ Anchor Roma Plus make), Hot dip galvanizes metal (Modular) control box (Similar to switches make) and 6 Modular cover frame (Legrand Arteor /Schneider Zen Celo/ Gold Medal GIFA /Honeywell Blenge Plus/ Million M-Vee make) including all labour charges etc., complete for light, bell, fan and exhaust fan points in Non-Residential Buildings.

70

892

62482

... More
Repairs to control room at 132 kV Manoharabad SS;Supply, Transportation and Fixing of 20W +/-10%, >/ 2000 lumens, 1200mm length LED retro tube light, housing made with PC body, wide operating voltage with Single / double side connection, PF=0.9, Surge protection: > 2KV, THD<15%, with inbuilt driver and frosted cover CCT: 3000K - 6500K as desired by the department and as per IS specifications, minimum CRI=80,.etc complete with 5 years warranty with BIS Certification.. LUMINAIRE MAKE: Phillips / OSRAM / Wipro / Crompton / Bajaj /Havells / Jaquar /Panasonic /Halonix / HPL / Eveready. LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA / OSRAM / SAMSUNG / LG LEDs. including fixing on ceiling or wall with all accessories, giving connections, cost & conveyance of all materials and labour charges etc., complete as directed by the Engineer in charge for finished item of work.

20

734

14686.6

... More
Repairs to control room at 132 kV Manoharabad SS;Supply, Transportation and fixing of energy efficient fan, 1200 mm sweep, aluminium body, consuming 28 W, BEE 5 star rated, ceiling fan with Brush Less Direct Current(BLDC)motor, class of insulation: B, 3 no's blades, 30 cm long down rod, 2 no's canopies, shackle'kit, safety rope, copper winding, Power Factor greater than 0.90, Service Value (CMMAV) greater than 8.0, Air delivery minimum 235 CMM, 350 RPM (tolerance as per IS:374-2019), THD less than 10%. with remote or compatible to electronic step type regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C(max), insulation resistance more than 2 mega ohm, suitable for 230V, 50 HZ, single phase AC supply, earthing etc., including all standard accessories etc., complete.Makes : Atomberg (Efficio ) / Havells / Orient/ Halonix/ Crompton including cost of all fittings and fixtures, labour for fixing at all positions of building giving electrical connections with necessary tools complete as directed by the Engineer in charge for finished item of work.

10

3610

36104.5

... More
Repairs to control room at 132 kV Manoharabad SS;Supply and fixing in position 32A. Main Switch (Sputnik or equivalent make) and including giving connections and labour charges and cost of materials complete as directed by the Engineer in charge for the finished item of work at all levels of building.

1

885

885

... More
Repairs to control room at 132 kV Manoharabad SS;Supply and fixing of 4 Way SPN DB with IP 20 Protection as per IS:13032 and suitable for 4Nos S.P out goings and for 1 No Incommer etc complete of makes Legrand / Schneider / Siemens / L&T / Cabtree Xpro make) with IP-20 protection suitable for 1 No. 40A single phase ELCB/RCCB/DP Isolator (Legrand-DX3 / Schneider-Acti9 / Siemens / L&T Exora /Cabtree) as incomer and 4 Nos. 10KA-6-32A SP MCBs (Legrand-DX3 / Schneider-Acti9 / Siemens / L&T Exora /Cabtree) as out-going including internal connection and labour charges and cost of materials complete as directed by the Engineer in charge for the finished item of work at all levels of building for surface/flush mounting.

4

4878

19512.44

... More
Repairs to control room at 132 kV Manoharabad SS;Run 2 of 56/0.30 (4.0Sqmm) FRLSH / HFFR PVC insulated 1100V grade as per IS:694 / 2010, IS 17048 specification for Copper cable (Makes: Finolex / RR kabel / Havells /Polycab / Beljin (HFFR) / Finecab Gold (HFFR) / GM (HFFR) / Gold Medal (HFFR) / Million(HFFR) /KEI (HFFR) / V-Guard (HFFR)) in existing pipe for run of Mains from Main switch to Distribution board as per colour code of wires including giving connections and labour charges and cost of materials complete as directed by the Engineer in charge for the finished item of work at all levels of building.

50

163

8187.5

... More
Repairs to control room at 132 kV Manoharabad SS;Supply and fixing of 6A/10A 3/2 pin modular socket of (Legrand Lyncus / GM Four Five/ Million/ Gold Medal Curve/ Anchor Roma Plus make) etc with 6A modular switch control of same make on a common switch board with earth continuity including wire leads, earth connections along with all labour charges etc., complete as per the directions of the Engineer in charge at site.

10

323

3238.7

... More
Repairs to control room at 132 kV Manoharabad SS;Supply and fixing of 16A /6 A, 1 way 2 Module Combi Socket with indicator lamp /fuse unit of (Legrand Lyncus / GM Four Five/ Million/ Gold Medal Curve/ Anchor Roma Plus make) etc with 16A modular switch control (same make.)on a common switch board with earth continuity including wire leads, earth connections along with all labour charges etc., complete as per the directions of the Engineer in charge at site.

8

457

3663.2

... More
Repairs to control room at 132 kV Manoharabad SS;Providing & Placing on Terrace (at all floor levels) polyethylene water storage tank of 1000 Ltrs capacity with Double layer approved brand & manufacture (SINTEX or equivalent ISI make) with cover and suitable locking arrangement & making necessary holes for inlet & outlets and over flow pipes but without fittings & base support for tanks including cost and conveyance of all materials, all fixtures, all leads and lifts complete as per the directions of the Engineer in charge for the finished item of work.

2

11420

22840.66

... More
Repairs to control room at 132 kV Manoharabad SS;Supply & Fixing of 15 mm brass body CP finish bib tap of not less than 300 grams weight screw type (full turn) with internal / external threaded connection conforming to IS 8931 (Jaquar/ CERA/ H & R Johnson make) including cost & conveyance of all materials, labour charges, leads, lifts complete as per the directions of the Engineer in charge for the finished item of work .

2

299

598.2

... More
Repairs to control room at 132 kV Manoharabad SS;Supplying and fixing of 15 mm NP stop cock (Jaquar/ CERA/ H & R Johnson make) including cost and conveyance, labour for fixing complete as per the directions of the Engineer in charge for the finished item of work.

2

474

948

... More
Repairs to control room at 132 kV Manoharabad SS;Supply & fixing 15 mm brass body CP finish bib cock of not less than 300 grams weight (Jaquar/ CERA/ H & R Johnson make) heavy duty including cost and conveyance, labour for fixing complete as per the directions of the Engineer in charge for the finished item of work.

2

300

600

... More
Repairs to control room at 132 kV Manoharabad SS;Supplying and fixing long body C.P. Taps (Jaquar/ CERA/ H & R Johnson make) including cost and conveyance, labour charges complete as per the directions of the Engineer in charge for the finished item of work.

2

260

520

... More
Repairs to control room at 132 kV Manoharabad SS;Providing and fixing in position at all levels of the building under floors and against walls 75mm dia (6kg/cm2) PVC pipes of Supreme/APL Apollo/ Ashirvad/ Birla Aerocon make with specials such as junctions,couplers, bends/Tees etc., with or without access doors as required and with solvent jointing as per standard practice wherever necessary including cost of all materials, labour charges, excavation and refilling wherever required,, testing etc. complete as per the directions of the Engineer in charge for the finished item of work.

10

297

2976.6

... More
Repairs to control room at 132 kV Manoharabad SS;Providing and fixing in position at all levels of the building under floors and against walls 110mm dia (6kg/cm2) PVC pipes of Supreme/APL Apollo/ Ashirvad/ Birla Aerocon make with specials such as junctions,couplers, bends/Tees etc., with or without access doors as required and with solvent jointing as per standard practice wherever necessary including cost of all materials, labour charges, excavation and refilling wherever required,, testing etc. complete as per the directions of the Engineer in charge for the finished item of work.

25

465

11637.75

... More
Repairs to control room at 132 kV Manoharabad SS;Providing and fixing 101.6 mm dia UPVC Nahani Trap/Floor trap with standard make Supreme/APL Apollo/ Ashirvad/ Birla Aerocon including making connection to PVC pipes/waste water lines with cement concrete base for embedding traps in position, finishing up to floor level with water proof cement plaster with grating at top complete as per the directions of the Engineer in charge for the finished item of work.

4

271

1087.64

... More
Repairs to control room at 132 kV Manoharabad SS;Providing and fixing in position at all levels of the buildings Bronze Gate (GM peet) Valve (Tata/Zenith make) as per IS-778 class- 1, Indian make heavy type for water services with hand wheel at all elevations for following sizes including cost of all materials, labour charges, jointing complete as per the directions of the Engineer in charge for the finished item of work. 15mm dia Nominal Bore

2

761

1522.72

... More
Repairs to control room at 132 kV Manoharabad SS;Providing and fixing in position at all levels of the buildings Bronze Gate (GM peet) Valve (Tata/Zenith make) as per IS-778 class- 1, Indian make heavy type for water services with hand wheel at all elevations for following sizes including cost of all materials, labour charges, jointing complete as per the directions of the Engineer in charge for the finished item of work. 25mm dia Nominal Bore

2

1472

2945.36

... More
Repairs to control room at 132 kV Manoharabad SS;Providing and fixing in position at all levels of the buildings Bronze Gate (GM peet) Valve (Tata/Zenith make) as per IS-778 class- 1, Indian make heavy type for water services with hand wheel at all elevations for following sizes including cost of all materials, labour charges, jointing complete as per the directions of the Engineer in charge for the finished item of work. 32 mm dia Nominal Bore

2

2237

4474.6

... More
Repairs to control room at 132 kV Manoharabad SS;Supplying and fixing CPVC pipes - SDR 13.5 of premium make Supreme/ Prince/ Astral/ Birla Aerocon including the cost of pipe, required number of connectors such as elbows, tees, couplers, connectors, solvent cement etc., and labour charges complete including cost and conveyance of all materials to site, all operational, incidental , labour charges, etc. complete for finished item of work as directed by Engineer-in-charge. 15.90 mm Outer dia Pipe

20

249

4981.4

... More
Repairs to control room at 132 kV Manoharabad SS;Supplying and fixing CPVC pipes - SDR 13.5 of premium make Supreme/ Prince/ Astral/ Birla Aerocon including the cost of pipe, required number of connectors such as elbows, tees, couplers, connectors, solvent cement etc., and labour charges complete including cost and conveyance of all materials to site, all operational, incidental , labour charges, etc. complete for finished item of work as directed by Engineer-in-charge.28.6 mm Outer dia Pipe

50

415

20774

... More
Repairs to control room at 132 kV Manoharabad SS;Supplying and fixing CPVC pipes - SDR 13.5 of premium make Supreme/ Prince/ Astral/ Birla Aerocon including the cost of pipe, required number of connectors such as elbows, tees, couplers, connectors, solvent cement etc., and labour charges complete including cost and conveyance of all materials to site, all operational, incidental , labour charges, etc. complete for finished item of work as directed by Engineer-in-charge. 34.90 mm Outer dia Pipe

50

629

31487.5

... More
Repairs to control room at 132 kV Manoharabad SS;Supplying and fixing TV Shape mirror with with Plastic frame size 609.6x457.2mm including cost & conveyance of all materials and labour for fixing complete as per the directions of the Engineer in charge for the finished item of work.

1

613

613.43

... More
Repairs to control room at 132 kV Manoharabad SS;Supplying and fixing CP finish Brass Soap dish heavy type with NP Screws (Jaquar/ CERA/ H & R Johnson make) including cost & conveyance of materials and labour for fixing complete as per the directions of the Engineer in charge for the finished item of work.

1

685

685.22

... More
Repairs to control room at 132 kV Manoharabad SS;Supplying and fixing CP finish steel towel rod of 600 mm long and 20 mm dia with brackets of Ist quality (Jaquar/ CERA/ H & R Johnson make) as per the directions of the Engineer in charge for the finished item of work.

1

482

482.92

... More
Repairs to control room at 132 kV Manoharabad SS;Supplying and fixing white glazed flat back Bowl urinal basin (Indian type) of size 440x265x315mm (Jaquar/ CERA/ H & R Johnson make) including all fixtures, labour for fixing as per the directions of the Engineer in charge for the finished item of work.

1

1196

1196.42

... More
Repairs to control room at 132 kV Manoharabad SS;Supplying and fixing Pedestal for wash hand basin (Jaquar/ CERA/ H & R Johnson make) including cost of all fixtures, labour for fixing as per the directions of the Engineer in charge for the finished item of work.

1

1739

1739.15

... More
Repairs to control room at 132 kV Manoharabad SS;Supplying & Fixing Indian make Flat Back Wash Hand Basin (Jaquar/ CERA/ H & R Johnson make) 1st quality conforming to IS:2556-Part-4:1972 with waste fittings like rubber plug, chain, 32 mm nominal size C.P. Fitting with parallel pipe thread conforming to IS:2963-1979 and fitted with 15 mm nominal bore Chromium Plated Pillar Tap of 1st quality Indian make 400 grams Seiko/ Esso or equivalent complete with standard CI brackets including wooden block: 550x400 mm- single C.P. Pillar cock including fittings and making chases, holes, etc., and making good the same where required including materials labour equipment all complete as per specifications and as per the directions of the Engineer-in-charge for the finished item of work.

1

2545

2545.1

... More
Repairs to control room at 132 kV Manoharabad SS;Supplying and fixing 580mmx440mm Orissa Pan white glazed W.C 1st quality ISI marked (Jaquar/ CERA/ H & R Johnson make) conforming to IS:2556-Part-3-2004 water closet with "P" or "S" trap with low level 10 ltrs. PVC (Slim line) flushing cistern with internal components and short bend, hard rubber seat, P-trap, stop-cocks, 32 mm GI flush pipe with fittings, C14s, PVC pipe connections with union at both ends, angle stop cock including painting and fittings and making chases, holes, etc., and making good the same where required including materials labour equipment all complete as per specifications and as per the directions of the Engineer-in-charge for the finished item of work.

1

4943

4943.37

... More
Repairs to control room at 132 kV Manoharabad SS;Providing skirting to internal walls to 15 cm height/risers of steps with Double charged / multi charged stain free full body porcelain vitrified tiles with double layer pigment of size 800 x 800 mm and thickness 9-11 mm 1st quality conforming to IS:13711, IS:13712, IS:13630 (Parts 1 to 15) of any colour and finish in all shades (Make: H&R Johnson, Kajaria, Cera, Varmora, Somany, RAK) and designs length equal to flooring stones, set over base coat of CM (1:5) 12 mm thick with cement slurry of honey like consistency spread at the rate of 3.30 kgs per M2 and jointed with white cement paste mixed with pigment of matching shade to full depth, including cost of all materials like tiles, cement, sand and water etc., curing complete as per the directions of the Engineer in charge for the finished item of work.

10

1216

12164.9

... More
Repairs to control room at 132 kV Manoharabad SS;Flooring with Double charged / multi charged stain free full body porcelain vitrified tiles with double layer pigment of size 800 x 800 mm and thickness 9-11 mm 1st quality conforming to IS:13711, IS:13712,IS:13630 (Parts 1 to 15) of any colour and finish in all in all shades (Make: H&R Johnson, Kajaria, Cera, Varmora, Somany, RAK) and designs as directed by Engineer in charge, set over base coat of cement mortar (1:8), 12 mm thick over CC bed already laid or RCC roof slab, including neat cement slurry of honey like consistency spread @ 3.3.kgs per sqm & jointed neatly with white cement paste to full depth mixed with pigment of matching shade, including cost of all materials like cement, sand, water and tiles etc., curing complete as per the directions of the Engineer in charge for the finished item of work.

150

1208

181237.5

... More
Repairs to control room at 132 kV Manoharabad SS;Laying of Cement Concrete (1:4:8) mix using 50% of 40mm size and 50% of 20mm HBG metal for bed flooring including cost and conveyance of all materials at all leads and lifts, ramming, consolidating, curing etc,complete. for finished item of work as per directions of the Engineer-in-charge.

17

4586

77970.84

... More
Repairs to control room at 132 kV Manoharabad SS;Laying of Plain Cement concrete - Nominal Mix (1:3:6) with 20mm graded HBG metal for fixing hold fasts in Brick walls with necessary form work including all operational, incidental and labour charges such as machine mixing, laying concrete, curing, cost and conveyance of all materials, labour charges, water lead, tools and tackles, all leads & lifts etc. complete for finished item of work as per directions of the Engineer-in-charge (IS 456)

2

5539

11079.92

... More
Repairs to control room at 132 kV Manoharabad SS;Plastering with CM (1:5), 12 mm thick with sponze finishing to the even wall surfaces including cost & conveyance of all materials, labour charges, leads, lifts , scaffolding and curing complete as per the directions of the Engineer in charge for the finished item of work.

15

169

2540.1

... More
Repairs to control room at 132 kV Manoharabad SS;Construction of Brick Masonry in CM (1:6) with common burnt clay bricks of class as per Table-1 of IS:1077-1992 Non-Modular or traditional size 23 x 11 x 7 cms of approved quality, including cost & conveyance of all materials, labour charges, scaffolding leads, lifts and curing complete as per the directions of the Engineer in charge for the finished item of work .

3

8203

24609.3

... More
Repairs to control room at 132 kV Manoharabad SS;Flooring with Non-skid Ceramic floor tiles of scratch free-stain free and scratch free-nano finish of size 300 x 300 mm and thickness 7-8 mm 1st quality conforming to IS:13711, IS:13712,IS:13630 (Parts 1 to 15) of any colour and finish in all in all shades (Make: H&R Johnson, Kajaria, Cera, Varmora, Somany, RAK) and designs as directed by Engineer. in charge, set over base coat of cement mortar (1:8), 12 mm thick over CC bed already laid or RCC roof slab, including neat cement slurry of honey like consistency spread @ 3.3.kgs per sqm & jointed neatly with white cement paste to full depth mixed with pigment of matching shade, including cost of all materials like cement, sand, water and tiles etc., curing complete as per the directions of the Engineer in charge for the finished item of work.

90

846

76169.7

... More
Repairs to control room at 132 kV Manoharabad SS;Supply and fixing in position M.S. grills/Angles/gates of required size of approved design and quality. (for, gates, windows, hand railing in front of portico, retaining walls ,) and painting with two coats of synthetic enamel paint of approved quality, make, colour and shade over one coat of red oxide, complete as per the directions of the Engineer in charge for the finished item of work.

700

119

83370

... More
Repairs to control room at 132 kV Manoharabad SS;Supply and fixing in position G.I. chequered plates of required size of approved design and quality. over cable duct in control room including cost of galvanizing complete as per the directions of the Engineer in charge for the finished item of work.

1500

116

175380

... More
Repairs to control room at 132 kV Manoharabad SS;Providing & fixing 30 mm thick solid panel PVC door shutter consisting of frame made out of 19 gauge M.S tube of 19 x 19 mm for stiles, top & bottom rail, with a coat of primer of approved make. M.S. Frame covered with 5 mm thick heat moulded PVC ?C? channel of size of 30 x 50 mm forming stiles, 5 mm thick 75 mm wide PVC sheet for top, lock & bottom rail on either side20 mm wide cross PVC sheet as gap insert fortop & bottom rail, panelling of 10mm(+/-) (5mm+5mm)? thick PVC sheet fitted in the M.S. frame welded /sealed to the stiles, on either side joined together with solvent cement adhesive etc., additional 5 mm thick PVC strip of 20 mm width stuck on the interior side of the C channel using solvent cement, complete for the finished item of work as per direction of Engineer?in?charge.

4

3196

12786.4

... More
Repairs to control room at 132 kV Manoharabad SS;Supplying and fixing of Unplasticised Poly Vinyl Chloride (UPVC) openable doors with openable shutters duly manufactured using UPVC reinforced profiles (Composition of profile shall consists a minimum of 5.5 PHR of TiO2 and not more than 12 PHR of CaCo3 for every 100 parts of PVC resin) of 60 mm x 55 mm x 2.40 mm for outer frames, 74 mm x 60 mm x 2.40 mm for mullion sections as per the need and 102 mm x 60 mm x 2.40 mm for openable shutter frame capable of mounting single glazing system structurally reinforced with hot dip galvanized up to 50 microns of minimum thickness of 1.2 mm prefabricated & welded through fusion welding the door sash shall be fitted with 6 mm thick clear float glass of reputed make duly fixed with Grey colour TPV Gaskets for sash & Glazing bead shall be co-extruded with Grey colour soft PVC System shall be provided with 4 no?s of 3D Hinges for each shutter and multipoint locking with keys with raiser wedges for smooth operation and the system is to be installed at the site using anchor fasteners, silicon rubber sealant, easy glazing/ deglazing at site etc., including cost and conveyance of all materials, accessories, labour charges for transportation, erection at site complete for finished item of work as directed by the Engineer-in-Charge. Approved brand -Fenesta/ NCL/ LG.

16

9292

148686.08

... More
Repairs to control room at 132 kV Manoharabad SS;Supplying and fixing of Unplasticised Poly Vinyl Chloride (UPVC) sliding windows two track sliding duly manufactured using UPVC reinforced profiles of (62 mm x 60 mm)/(60 mm x 45 mm)/ (60 mm x 52mm) x 2.0 mm for outer frames, (66 mm x 38 mm)/(58mm x 39 mm)/ (60 mm x 42 mm) x 2.0 mm for sliding shutter frames capable of mounting single glazing system, structurally reinforced with hot dip galvanized up to 50 microns of minimum thickness of 1.2 mm prefabricated & welded through fusion welding the window sash shall be fitted with 5 mm thick clear float glass of reputed make duly fixed with TPV Gaskets/ EPDM weathering seal resistant accessories like locking system 1 No., per set of sashes and the system is to be installed at the site using anchor fasteners, silicon rubber sealant, easy glazing/ deglazing at site etc.,including cost and conveyance of all materials, accessories, labour charges for transportation, erectionat site with templates for casement sizing complete as per the directions of Engineer-in-charge for finished item of work . Approved brand - Fenesta/ NCL/ LG.

23

7415

170558.8

... More
Repairs to control room at 132 kV Manoharabad SS;Providing Tar felting roof repairs with Zori-felt BT or equivalent duly applying one coat of appropriate grade of bitumen in hot condition @ 1.2 Kg/1Sqm of roof area, fixing tar felt (Manufactures to IS 1322/1972 specification), applying second coat of appropriate grade of hot bitumen at 1.20 Kg/1Sqm of roof area and spreading course aggregate (sand) at 0.063 cum per 1 Sqm of roof area finished item of work and as directed by engineer in charge.

255

421

107390.7

... More
Repairs to control room at 132 kV Manoharabad SS;Roofing with 6 mm thick corrugated asbestos cement sheets,fixing with G.I ?J ?bolts &nuts 8 mm dia G.I plain washers complete including seigniorage charges etc., complete for finished item of work, but excluding the cost of purlins, rafters, trusses & cost of conveyance of all materials -upto 60 degree pitch for finished item of work and as directed by Engineer in Charge.

270

538

145338.3

... More
Repairs to control room at 132 kV Manoharabad SS;Providing and fixing of False ceiling in true horizontal level 600mmx600mm,14mm thick Mineral fibre sheet 600x600 of fissured-ANF(board/Tegular)edge tiles with a humidity resistance of 90% RH,average NRC 0.50,light Reflectance>80% thermal conductivity /\=0.052 to .057w/mk,fire performance class0/class1 using hot dipped galvanised steel section exposed surface with pre-coated capping,main Tee of size24x32mm at every 1200c/c maximum and rotary stiched cross tee of size 24x27mm at every 600mm c/c and sub-cross tee of size 24mmx25mm at 1200mm c/c and wall angle of size 19x19 mm fixed to periphery of the wall and the above grid is suspended at every 1200c/c in both directions using 4.0mm thick pre-straightened GI Rod laying fine fissured butt edge ceiling tiles of 15mm thick mineral fibre board including cost and conveyance of all materials and labour charges such as cutting,fixing of standing of framework exposing roof making complete as per the directions of the engineer in charge for the finished item of work. (Recommended brands:Armstrong,Insula etc.,)

115

1294

148888.2

... More
Repairs to control room at 132 kV Manoharabad SS;Painting two coats with rubber based acid resistant paint of approved make and quality over a coat of Red oxide primer Gr-I to the walls, flooring and ceiling of the battery room including cost & conveyance of all materials, scaffloding, labour charges, leads, lifts etc, complete as per the directions of the Engineer in charge for the finished item of work

130

189

24601.2

... More
Repairs to control room at 132 kV Manoharabad SS;Painting to inner old walls with 2 coats of acrylic emulsion paint interior grade having VOC (Volatile Organic Compound) content less than 50 grams/ liter of approved brand ( Asian premier or equivalent) and to give an even shade after thourughly brushing the surface to remove all dirt and remains of loose powdered materials, including cost and conveyance of all materials to work site and all operational, incidental, labour charges etc.complete for finished item of work as per SS 911 for internal walls.

380

96

36506.6

... More
Repairs to control room at 132 kV Manoharabad SS;Painting to External old walls with 2 coats of acrylic emulsion paint exterior grade with silicon additives having VOC (Volatile Organic Compound) content less than 50 grams/ liter of approved brand ( Asian APEX or equivalent) and to give an even shade after thoroughly brushing the surface to remove all dirt and remains of loose powdered materials, including cost and conveyance of all materials to work site and all operational, incidental, labour charges etc.complete for finished item of work as per SS 912 for External walls

326

148

48349.06

... More
Repairs to control room at 132 kV Manoharabad SS;Specialised poly urethane sealant treatment to the external wall cracks and hairline cracks in walls by cleaning the surface and cutting the existing surface crack with electric cutter machine in ?U? shape to a width and depth of 3 to 4mm and filling the groove with high performance high bond high elastomeric single compound poly urethane sealant Roof seal PU (Armstrong make) including cost of all materials and labour etc complete as per directions of the engineer in charge for the finished item of work.

100

310

31000

... More
Repairs to control room at 132 kV Manoharabad SS;Dismantling, Cleaning & removal of existing Ceramic flooring/ Marble flooring/ Virtified Tile flooring/ skirting at all heights and disposing-off the debris out side the premises with a lead of 25 Km including all labour charges, all leads & lifts, taxes etc., complete for finished item of work as directed by the Engineer in charge.

23

71

1652.32

... More
Repairs to control room at 132 kV Manoharabad SS;Dismantling doors, windows and clear storey windows, ventilators etc.; (wood or steel) shutters including chowkhats, architraves, hold fasts and other attachments etc., complete and stacking them at departmental stores ( By departmental Vehicle) and disposing the unserviceable metraial away from site premises by contractors own transport as specified and directed by the engineer-in - charge.

38

225

8565.96

... More
Repairs to control room at 132 kV Manoharabad SS;Dismantling of existing Brick masonry including clearing away and carefully stacking materials useful for re use and all debris away from the site with lead & lift labour charges, T&P complete as per the directions of the Engineer in charge for the finished item of work.

1.5

255

383.69

... More
Repairs to control room at 132 kV Manoharabad SS;Dismantling , cleaning and removal existing asbestos roofing sheet at all heights and clearing all debris away from the site with initial lead & lift labour charges, T&P complete as per the directions of the Engineer in charge for the finished item of work.

255

29

7489.35

... More
Repairs to control room at 132 kV Manoharabad SS;removing of existing false ceiling including removing of grid and sheets and clearing away the debris from site as directed by the engineer in charge

115

125

14389.95

... More
Repairs to control room at 132 kV Manoharabad SS;Removing old paintings by steel wire brushing /or scraping, sand papering and preparing the wall surface smooth including necessery repairs to scratches and cutting grooves to cracks filling with lappam wherever necessery complete including clearing away the debris from substation site etc., complete as directed by the Engineer in Charge.

835

13

11339.3



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.