Telangana State Medical Services And Infrastructure Development Corporation Tender

For getting the details of etenders, if you are looking for information about them from the cumbersome government websites but are tired of doing so, Bidassist comes up with a one stop solution. It collates every Eproc telangana tender on Bidassist. One can approach it for the bidding process, registration process, etc., are explained below.

Telangana State Medical Services And Infrastructure Development Corporation - TSMSIDC Tender

Civil And Construction
Building Construction
Construction Works
Opening Date26 Sep 2022
Closing Date11 Oct 2022
Tender Amount₹ 33,42,02,394 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;SITC of Electrical Control panel should be automatic change over panel for changeover from A to B and then from B to A and then from B to C. If any pump trips then the second should start automatically. The panel should consist of contactors Amp meter, Volt meter, Single phase protector, MCB, phase indicator, compressor on ?off trip indicator and pressure switch .

1

-

303450

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Bed Head Panel : The bed Head Panel should have provision for Medical Gas outlet points as per requirement and Nurse call systems.it should be equpped with electrical switch, socket of 16 Amp, socket for 2+2

80

-

565520

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and fixing of BPC Flow meter with Humidifier bottle and probe near out let point, flow meter body made of brass material and should be back pressure compensated suitable for accurate gas flow measurement and control within a range of 0-15 litres per minute, flow tube and components should be mae of clear impact resistant polycarbonate and Humidifier shuld have built in safety valve and should be made of unbreakable polycarbonate material and autoclavable at 134 degrees centigrade, including cost and conveyance of materials, errection chages, commissioning charges etc. for finished item of work

80

-

108000

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Oxygen outlets (Indeginous) with Probes as per DIN standards.

80

-

150000

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;3 Gas Microprocessor Controlled Alarm With Digital Display

5

-

125000

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Ward Vacuum Unit complete with Regulator , collection bottle, Adapter and Bracket for collection bottle

80

-

137120

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Medical Air outlets (Indeginous) - with Probes as per DIN standards

80

-

150000

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Vacuum outlets (Indeginous) - with Probes as per DIN standards

80

-

150000

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and fixing of 54 mm dia. Isolation Valves with necessary end fittings designed for a working pressure of 300 psi / 27 inc. Hg. Vaccum/Oxygen, Non Ferrous, Non Lubricated with 90 degrees turn, Hand lever operated of standard make of valves including cost and conveyance of all mateials, taxes, transportation chrges, fixing charges and testing charges and all labour charges etc. comlete for finished item of work.54 mm Valves

3

-

15000

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and fixing of 28 mm dia. Isolation Valves with necessary end fittings designed for a working pressure of 300 psi / 27 inc. Hg. Vaccum/Oxygen, Non Ferrous, Non Lubricated with 90 degrees turn, Hand lever operated of standard make of valves including cost and conveyance of all mateials, taxes, transportation chrges, fixing charges and testing charges and all labour charges etc. comlete for finished item of work. 28 mm Valves

30

-

98250

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and fixing of 22 mm dia. Isolation Valves with necessary end fittings designed for a working pressure of 300 psi / 27 inc. Hg. Vaccum/Oxygen, Non Ferrous, Non Lubricated with 90 degrees turn, Hand lever operated of standard make of valves including cost and conveyance of all mateials, taxes, transportation chrges, fixing charges and testing charges and all labour charges etc. comlete for finished item of work. 22 mm Valves

30

-

61500

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and fixing of 15 mm dia. Isolation Valves with necessary end fittings designed for a working pressure of 300 psi / 27 inc. Hg. Vaccum/Oxygen, Non Ferrous, Non Lubricated with 90 degrees turn, Hand lever operated of standard make of valves including cost and conveyance of all mateials, taxes, transportation chrges, fixing charges and testing charges and all labour charges etc. comlete for finished item of work.15 mm Valves

50

-

72500

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and fixing of Medical grade Copper Pipe Lines of 54mm dia. 1.2mm thick for distribution, pipes shall be Solid drawn, seamless, deoxidezed, non-arsenical, half hard, tempered and degreased copper pipeconforming to EN 13348. All copper pipes should be degreased & delivered capped at both ends. The pipes should be accompanied with manufactureres test certificate for the physical properties & chemical composition. Copper pipe should also have third party inspection certificate from Lloyds' Register services including cost and conveyance of pipes, cost of necessary specials made of copper and suitable for a steam working pressure of 17 bar and should confirm to BS 864 with specially made for brazed socket type connections, including taxes, transportation charges including laying and jointing, testing, commissioning and all other labour charges etc. complete for finished item of work.(54mm O.D x 1.2mm thick copper pipe)

150

-

378000

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and fixing of Medical grade Copper Pipe Lines of 42 mm dia. 1.2mm thick for distribution, pipes shall be Solid drawn, seamless, deoxidezed, non-arsenical, half hard, tempered and degreased copper pipeconforming to EN 13348. All copper pipes should be degreased & delivered capped at both ends. The pipes should be accompanied with manufactureres test certificate for the physical properties & chemical composition. Copper pipe should also have third party inspection certificate from Lloyds' Register services including cost and conveyance of pipes, cost of necessary specials made of copper and suitable for a steam working pressure of 17 bar and should confirm to BS 864 with specially made for brazed socket type connections, including taxes, transportation charges including laying and jointing, testing, commissioning and all other labour charges etc. complete for finished item of work.(42mm O.D x 1.2mm thick copper pipe)

120

-

215160

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and fixing of Medical grade Copper Pipe Lines of 28 mm dia. 0.9 mm thick for distribution, pipes shall be Solid drawn, seamless, deoxidezed, non-arsenical, half hard, tempered and degreased copper pipeconforming to EN 13348. All copper pipes should be degreased & delivered capped at both ends. The pipes should be accompanied with manufactureres test certificate for the physical properties & chemical composition. Copper pipe should also have third party inspection certificate from Lloyds' Register services including cost and conveyance of pipes, cost of necessary specials made of copper and suitable for a steam working pressure of 17 bar and should confirm to BS 864 with specially made for brazed socket type connections, including taxes, transportation charges including laying and jointing, testing, commissioning and all other labour charges etc. complete for finished item of work. (28mm O.D x 0.90mm thick copper pipe)

150

-

165300

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and fixing of Medical grade Copper Pipe Lines of 22 mm dia. 0.9 mm thick for distribution, pipes shall be Solid drawn, seamless, deoxidezed, non-arsenical, half hard, tempered and degreased copper pipeconforming to EN 13348. All copper pipes should be degreased & delivered capped at both ends. The pipes should be accompanied with manufactureres test certificate for the physical properties & chemical composition. Copper pipe should also have third party inspection certificate from Lloyds' Register services including cost and conveyance of pipes, cost of necessary specials made of copper and suitable for a steam working pressure of 17 bar and should confirm to BS 864 with specially made for brazed socket type connections, including taxes, transportation charges including laying and jointing, testing, commissioning and all other labour charges etc. complete for finished item of work (22mm O.D x 0.90mm thick copper pipe)

180

-

160380

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and fixing of Medical grade Copper Pipe Lines of 15 mm dia. 0.9 mm thick for distribution, pipes shall be Solid drawn, seamless, deoxidezed, non-arsenical, half hard, tempered and degreased copper pipeconforming to EN 13348. All copper pipes should be degreased & delivered capped at both ends. The pipes should be accompanied with manufactureres test certificate for the physical properties & chemical composition. Copper pipe should also have third party inspection certificate from Lloyds' Register services including cost and conveyance of pipes, cost of necessary specials made of copper and suitable for a steam working pressure of 17 bar and should confirm to BS 864 with specially made for brazed socket type connections, including taxes, transportation charges including laying and jointing, testing, commissioning and all other labour charges etc. complete for finished item of work. (15mm O.D x 0.90mm thick copper pipe)

300

-

184800

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and fixing of Medical grade Copper Pipe Lines of 12 mm dia. 0.7 mm thick for distribution, pipes shall be Solid drawn, seamless, deoxidezed, non-arsenical, half hard, tempered and degreased copper pipeconforming to EN 13348. All copper pipes should be degreased & delivered capped at both ends. The pipes should be accompanied with manufactureres test certificate for the physical properties & chemical composition. Copper pipe should also have third party inspection certificate from Lloyds' Register services including cost and conveyance of pipes, cost of necessary specials made of copper and suitable for a steam working pressure of 17 bar and should confirm to BS 864 with specially made for brazed socket type connections, including taxes, transportation charges including laying and jointing, testing, commissioning and all other labour charges etc. complete for finished item of work. (12mm O.D x 0.7 mm thick copper pipe)

600

-

288000

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;2 x 4 Main Nitrous Oxide Manifold with 19 mm O.D x12 mm ID Copper Pipe mounted on Top Frame, Middle Frame and Bottom Frame, along with brass blocks,NRVs/Cylinder Valves and Pigtail Pipes of 1 mtr long of size 8 mm O.D x 3 mm I.D,duly tested at 250 Kg/Cm2 pressure. & Semi Automatic Control Panel for Nitrous Oxide.

1

-

45300

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;2 x 4 Oxygen Emergency Manifold with 19 mm O.D x12 mm ID Copper Pipe mounted on Top Frame with brass blocks,NRVs/Cylinder Valves and Pigtail Pipes of 1 mtr long of size 8 mm O.D x 3 mm I.D, duly tested at 250 Kg/Cm2 pressure with Single stage high flow / Double stage Regulator.

1

-

45300

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;2 x 20 Oxygen Main Manifold with 19 mm O.D x12 mm ID Copper Pipe mounted on Top Frame with brass blocks, NRVs/Cylinder Valves and Pigtail Pipes of 1 mtr long of size 8 mm O.D x 3 mm I.D,duly tested at 250 Kg/Cm2 pressure. & Fully Automatic Control Panel for Oxygen.

1

-

310900

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply, Installation, Testing and Commissioning of 1.0 Sq mm speaker cable etc., complete with connections

300

-

18600

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply, Installation, Testing and Commissioning of stand for microphone etc., complete with connections.

6

-

13500

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply, Installation, Testing and Commissioning of Amplifier 120 W for PA system suitable to operate on 230 V AC / 12 V DC supply etc., complete. Make : AHUZA / OMEGA or equivalent

3

-

67488

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply, Installation, Testing and Commissioning of 15 W Sound Column etc., complete with connection. Make : AHUZA / OMEGA or equivalent

30

-

104970

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and fixing 2 way fire brigade connection of cast iron body with 2 Nos Gun metal Male instantaneous inlet couplings complete with cap and chain as required for 100mm dia MS pipe connection, conforming to IS 904 as required. Make: Mini Max / Safex / Newage / Winco / Padmini.

1

-

7158

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and fixing 4 way fire brigade connection of cast iron body with 4 Nos Gun metal Male instantaneous inlet couplings complete with cap and chain as required for 150 mm dia MS pipe connection, conforming to IS 904 as required. Make: Mini Max / Safex / Newage / Winco / Padmini.

1

-

9544

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply of 95 Sqmm 3.5 Core XLPE insulated, 1100V grade armoured alluminium cable as per specification confirming to IS:7098 Makes : Torrent / Unicab / Universal / Polycab / Havells / Gloster / KEI / Finolex / Payal / RR kable / Finecab / RPG / V - Guard.

60

-

61560

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply, Transportation, laying, testing & commissioning following of 'B' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required Makes : Jindal / Hissar / Tata pipes 150mm dia

20

-

53300

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply, Transportation, laying, testing & commissioning following of 'B' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required Makes : Jindal / Hissar / Tata pipes 200mm dia

30

-

121980

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25mm dia Gun metal wheel valve, with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required.

2

-

35788

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and fixing Flow Switches in 150 mmdia MS pipe. Makes : System Sensor / Switzer

2

-

16702

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply, installation, testing and commissioning of 25mm dia Ball valve Makes : Zoloto / Leader / Honeywell

2

-

1524

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply, installation, testing and commissioning of Bourden type, stainless steel dial type pressure gauge with isolation valve and pipe having calibration of 0-16 kg/cm2. Makes : HGURU / FIEBIG

2

-

1574

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and fixing of Pressure Switch in the MS pipe Line including connection etc as required. Make : Danfoss / Indfoss

2

-

5964

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Designing, Supply, Transportation, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification Makes of MCCBs : L&T / Siemens / Legrand / Schneider / ABB / Hager Makes of Meters : Schneider (Conzerve) / L&T / Elmeasure / Siemens INCOMING : 630A, 50kA 4 Pole MCCB, Ics=100% Icu Rating Digital Voltmeter 0-500V with selector switch Ammeter (0-630 A) with selector swtich & CTs etc. LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 800Amps OUT GOING : ( Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps) MAIN FIRE PUMP 200 Amp, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 75 hp pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. - 2 sets JOCKEY PUMP 100 Amp, 50kA TPN MCCB, Ics=100% Icu, with Suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. - 2 sets DIESEL ENGINE CONTROL Control for diesel engine comprising - Automatic/Manual selctor switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0-20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engine System Controller.

1

-

512176

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supplying , installation , testing and commissioning of electric driven pressurisation / Jockey pump suitable for automatic operation and consisting of following : complete in all respect as required a) Horizontal type, multistage, centrifugal pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal and flow of 180 lpm at 70 Mtr head conforming to IS 1520 b) Suitable HP SQ cage induction motor TEFC type suitable for operation on 415Volts, 3 phase 50 Hz. AC with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325 c) M.S. Fabricated common base plate, coupling, coupling guard, foundation bolts etc as required. d) Suitable cement concrete foundation duly plastered with anti vibration pads. Makes of Pumps : Kirloskar / Mather&Platt. Makes of Motors : Siemens/ ABB/ Kirloskar

1

-

70294

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supplying , installation, Testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following : complete in all respect as required a) Horizontal type, multistage, centrifugal pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal to ensure a minimum pressure of 3.5 Kg / sq.cm. at highest and farthest outlet at specified flow of 1620 lpm at 56 Mtr head conforming to IS 1520 b) Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant BS & IS standard complete with auto starting mechanism, 12 Volts / 24 Volts electric starting equipment, Diesel Tank, exhaust pipe extended upto 1 m. outside pump house duly insulated with 50mm thick glass wool with 1.0mm thick alluminium sheet cladding, residential silencer, instruments and protection as per specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc as required. c) M.S. Fabricated common base plate, coupling, coupling guard, foundation bolts etc as required d) Suitable cement concrete foundation duly plastered with anti vibration pads. Makes of Engines : Kirloskar / Cummins. Makes of Pumps : Kirloskar / Mather&Platt

1

-

543534

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply, Transportation, installation , testing and commissioning of electric driven main fire pump suitable for automatic operation and consisting of following : complete in all respect as required. a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal to ensure a minimum pressure of 3.5 Kg / sq.cm. at highest and farthest outlet at specified flow of 1620 LPM at 56 Mtr. head conforming to IS 1520 b) Suitable HP SQ cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415Volts, 3 phase 50 Hz. AC with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325 c) M.S. Fabricated common base plate, coupling, coupling guard, foundation bolts etc as required. d) Suitable cement concrete foundation duly plastered with anti vibration pads. Makes of Pumps: Kirloskar / Mather&Platt. Makes of Motors: Siemens/ ABB/ Kirloskar

1

-

411570

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply, installation, testing and commissioning of 150 mm Dia stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.

2

-

29994

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Providing, installation, testing and commissioning of 150 mm dia dual plate non - return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc as required Makes: Audco / Kirloskar / BDK / H-Shankar / Leader/ Zolotto / Intervalve / Honeywell. 150 mm dia

2

-

22396

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supplying and wrapping the anticorrosive material for buried pipes with coating of Primer and wrapping with 4 mm thick polymer corrosion resistant tape as per IS : 10221 with 15 mm overlap as per specificatios. 100mm dia

20

-

9240

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supplying and wrapping the anticorrosive material for buried pipes with coating of Primer and wrapping with 4 mm thick polymer corrosion resistant tape as per IS : 10221 with 15 mm overlap as per specificatios. 150mm dia

40

-

21000

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supplying, fixing, testing and commissioning of butterfly valve PN 1.6, with Bronze / Gun metal seat duly ISI marked complete with Nuts, Bolts, Washers, gaskets, conforming to IS 13095 of following sizes as required. Makes: Audco / Kirloskar / BDK / H-Shankar / Leader/ Zolotto / Intervalve / Honeywell. 150mm dia (SUCTION )

1

-

7124

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supplying, fixing, testing and commissioning of butterfly valve PN 1.6, with Bronze / Gun metal seat duly ISI marked complete with Nuts, Bolts, Washers, gaskets, conforming to IS 13095 of following sizes as required. Makes: Audco / Kirloskar / BDK / H-Shankar / Leader/ Zolotto / Intervalve / Honeywell. 150mm dia ( Delivery )

2

-

14248

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply, Transportation, installation , testing and commissioning of electric driven Terrace / Booster pump suitable for automatic operation and consisting of following : complete in all respect as required. a) Horizontal type, multistage, centrifugal pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal and flow of 900 LPM lpm at 45 Mtr head conforming to IS 1520 b) Suitable HP SQ cage induction motor TEFC type suitable for operation on 415Volts, 3 phase 50 Hz. AC with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325 c) M.S. Fabricated common base plate, coupling, coupling guard, foundation bolts etc as required. d) Suitable cement concrete foundation duly plastered with anti vibration pads. Makes of Pumps : Kirloskar / Mather&Platt. Makes of Motors : Siemens / ABB / Kirloskar

1

-

79701

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply, installation, testing and commissioning of 150 MM dia stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange

1

-

14997

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Providing, installation, testing and commissioning of dual plate non - return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc as required Makes: Audco / Kirloskar / BDK / H-Shankar / Leader/ Zolotto / Intervalve / Honeywell. 150 mm dia

2

-

22396

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supplying, fixing, testing and commissioning of butterfly valve PN 1.6, with Bronze / Gun metal seat duly ISI marked complete with Nuts, Bolts, Washers, gaskets, conforming to IS 13095 of following sizes as required. Makes: Audco / Kirloskar / BDK / H-Shankar / Leader/ Zolotto / Intervalve / Honeywell. 100mm dia

2

-

11122

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supplying, fixing, testing and commissioning of butterfly valve PN 1.6, with Bronze / Gun metal seat duly ISI marked complete with Nuts, Bolts, Washers, gaskets, conforming to IS 13095 of following sizes as required. Makes: Audco / Kirloskar / BDK / H-Shankar / Leader/ Zolotto / Intervalve / Honeywell. 150mm dia

1

-

7124

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply, Transportation, laying, testing & commissioning following of 'B' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required Makes : Jindal / Hissar / Tata pipes 100 mm dia Two Way Fire Brigade risers

20

-

36040

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply, Transportation, laying, testing & commissioning following of 'B' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required Makes : Jindal / Hissar / Tata pipes 150mm dia

100

-

266500

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and fixing of Escape signage boards in Rigid Photo luminecent based glow in Dark rigid sheet with high intensity luminous properties with specificaiton of Cease Fire or its equivalent Make Model-1ES01

24

-

36384

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and fixing of 2 Kg Fire exitinguisher Clean Agent HCFC 123, Stored pressure type, IS 15683 : 2006 pressure guage, gross weight 3.7 Kg empty weight 1.7 Kg, can hight 344mm, Diameter 108mm, discharge time minimum 8 secs, controllable discharge mechanism, range minimum 2 meters, applicable on class A,B,C and electrically started Fire, A rating 1A, B rating 21B, can construction: Deep drawn & CO2 mig welded, Valve construction: Forging & Machining, Internal coating of Can: Epoxy powder coating, External coating of can: Epoxy polyster powder coating, sheet metal thickness: 1.60 mm, Helium leak detection tested, ISI & CE approved, 5 Years warranty. Makes : Safex / Kenex / Bharat

20

-

256080

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and fixing of ABC Powder MAP 2 Kg Fire extinguisher Mono ammonium phosphate power 90, stored pressure type, IS 15683 : 2006, pressure gauge gross wt. 3.6 kg, empty wt. 1.6 kg, can Ht.344mm, Diameter 108mm, Discharge time less than 8 sec, controllable discharge mechanism, range min. 2 mts applicable on classes A,B, C electrically started fires, A- rating 2A, B-rating 21B, can construction: Deep drawn Co2 mig welding, wall construction: Forging & Machining, internal coating of can: Epoxy power coating, External coating of Can:Epoxy polyster powder coating, sheet metal thickness:1.60mm, Helium leakage detection tested, insta - alert, ISI & CE approved with 5 years warranty Including transportation, all taxes and all labour charges etc complete. Makes : Safex / Kenex / Bharat / Reliance

40

-

135880

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and fixing of ABC Powder MAP 4 Kg Fire extinguisher Mono ammonium phosphate power 90, stored pressure type, IS 15683 : 2006, pressure gauge gross wt. 6.9 kg, empty wt. 2.9 kg, can Ht.440mm, Diameter 140mm, Discharge time less than 13 sec, controllable discharge mechanism, range min. 4 mts applicable on classes A,B, C & electrically started fires, A- rating 3A, B-rating 34B, can construction: Deep drawn Co2 mig welding, wall construction: Forging & Machining, internal coating of can: Epoxy power coating, External coating of Can:Epoxy polyster powder coating, sheet metal thickness:1.60mm, Helium leakage detection tested, ISI & CE approved with 5 years warranty Including transportation, all taxes and all labour charges etc complete. Makes : Safex / Kenex / Bharat / Reliance

40

-

193360

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply & Fixing of 4.5Kg, CO2 Type Fire Extinguisher, Trolley Mounted, Easy Weight Management, Used Unused Mechanism, Squeeze Grip, Gross Weight 19.1 Kg, Empty Weight 14.6 Kg, Can Height 860MM, Diameter 140MM, Discharge time minimum 13 Secs, Controllable discharge mechanism, Range minimum 2 Meters, Applicable on Class B,C & electrically started Fire, B Rating 13B, Can Construction : Hot Spinning / Forging, Valve Construction : Forging & Machining, Internal Coating of Can : Not Applicable, External Coating of Can : Spray Painting, Sheet metal thickness : 4.5MM, ISI & CE Approved, 2 Year Warranty Including transportation, all taxes and all labour charges etc complete. Makes : Safex / Kenex / Bharat / Reliance

10

-

95380

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and Run of 2 Core x 1.5Sqmm FRLS armoured copper cable on ceiling / wall as per IS. 7098 / Part-I / 1988 including all taxes etc., complete. Makes: Finolex / RR kabel / Havells / Polycab / RPG / KEI / V-Guard.

384

-

46080

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and fixing of addressable wall mounting strobes cum hooters including the cost of mounting accessories complete as per specifications and as required including testing and commissioning. Makes: Siemens / Morley IAS / Bosch / Ravel / Honeywell / cooper

16

-

67728

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and installation of addressable analogue manual call point with resetable flexible element to initiate alaram including the cost of mounting accessories etc. complete. Makes: Siemens / Morley IAS / Bosch / Ravel / Honeywell / cooper.

16

-

72800

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and installation of UL approved intellegent analogue addressable multi criterion detectors below false ceiling/on ceiling including the cost of base plate. 75mm dia MS outlet box for fixing of the detector base, mounting accessories etc., complete as per specifications and as required. Makes: Siemens / Morley IAS / Bosch / Ravel / Honeywell / Cooper.

20

-

78540

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply, Installation, testing and commissioning of UL approved intellegent analogue addressable Repeater panel including the cost of mounting accessories complete as per specification as required. Makes: Siemens / Morley IAS / Bosch / Ravel / Honeywell / cooper.

1

-

94085

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and Installation of UL approved intellegent analogue addressable fault isolator modules including the cost of mounting accessories complete as per specifications and complete as required. Makes: Siemens / Morley IAS / Bosch / Ravel / Honeywell / Cooper.

16

-

57568

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and Run of 2 Core x 1.5Sqmm FRLS armoured copper cable on ceiling / wall as per IS. 7098 / Part-I / 1988 including all taxes etc., complete. Makes: Finolex / RR kabel / Havells / Polycab / RPG / KEI / V-Guard.

4550

-

546000

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply, Installation, testing and commissioning of EN54-2 Listed and UL approved based analog addressable 4 loop micro processor fire control panel expandable by minimum 2 additional loops with minimum 640 character LCD display. Each loop of panel shall have maximum capacity 250analogue addressable devices, and shall have 20% of spare capacity, 240 volts A C Power supply, automatic battery charger, 24V SLA batteries suitable for operating the entire system including tack back units and the hooters/strobes for a minimum of 4 hours in battery condition the panel shall have suitable power amplifiers for hooter / strobes the panel shall be capable being integrated with the BMS system and shall include cost of supply, installation of any additional modules or interfaces required for the same Makes: Siemens / Notifier / Edwards / Honeywell / Morley IAS / Bosch / Cooper

1

-

326643

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and installation of UL approved intellegent analogue addressable rate of rise cum fixed temparature heat detectors including the cost of base plate. 75mm dia MS outlet box for fixing of the detector base, mounting accessories etc., complete as per specifications and as required. Makes: Siemens / Morley IAS / Bosch / Ravel / Honeywell / Cooper.

20

-

74080

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and installation of response indicators for above false ceiling detectors. Makes: System Censor / Ravel / Vertex / Seaara

60

-

10200

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and instllation of UL approved intellegent analogue addressable photo electric smoke detector including cost of base plate etc., complete as per specification with required fittings and accessories. Makes: Notifier / Edwards / Honeywell / Morley IAS / Bosch / cooper.

275

-

1050775

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply, installation, testing & commissioning of electric release trim assembly for deluge wall with two way solelnoid valve, weather proof operation on 24 volts DC supply complete as required.

1

-

7499

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply, Transportation, laying, testing & commissioning following of 'B' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required Makes : Jindal / Hissar / Tata pipes 50 mm Dia For Drain Pipe

100

-

81300

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and fixing Flow Switches in 150 mmdia MS pipe. Makes : System Sensor / Switzer

3

-

25053

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supplying, fixing, testing and commissioning of 150 mm Dia butterfly valve PN 1.6, with Bronze / Gun metal seat duly ISI marked complete with Nuts, Bolts, Washers, gaskets, conforming to IS 13095 of following sizes as required. Makes: Audco / Kirloskar / BDK / H-Shankar / Leader/ Zolotto / Intervalve / Honeywell.

6

-

42744

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply, installation, testing & commissioning of sprinkler 1.5 Mtrs flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. Makes: SAFEX / HD / TYCO / VIKING / NEWAGE / SHARP

160

-

238720

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply, fabricating , installing structural steel supports for fixing all sizes of MS pipes from ceiling / wall with MS Channels, Angles, Flats, Rods, as required at site with anchor fasteners, Clamps, threaded rods, nuts, bolts,washers etc complete with painting

1000

-

134000

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply, fixing, testing and commissioning of 15mm size quartzoid bulb type sprinklers of rating 68ºC. pendent / side wall with required accessories. Makes: SAFEX / HD / TYCO / VIKING / NEWAGE / Newtech / SHARP. Side wall

40

-

22920

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply, fixing, testing and commissioning of 15mm size quartzoid bulb type sprinklers of rating 68ºC. pendent / side wall with required accessories. Makes: SAFEX / HD / TYCO / VIKING / NEWAGE / Newtech / SHARP. Pendant

350

-

200550

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply, Transportation, laying, testing & commissioning following of 'B' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required Makes : Jindal / Hissar / Tata pipes 25 mm dia

1400

-

581000

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply, Transportation, laying, testing & commissioning following of 'B' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required Makes : Jindal / Hissar / Tata pipes 32mm dia

1000

-

509000

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply, Transportation, laying, testing & commissioning following of 'B' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required Makes : Jindal / Hissar / Tata pipes 40 mm dia

200

-

112800

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply, Transportation, laying, testing & commissioning following of 'B' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required Makes : Jindal / Hissar / Tata pipes 50mm dia

180

-

146340

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply, Transportation, laying, testing & commissioning following of 'B' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required Makes : Jindal / Hissar / Tata pipes 65mm dia

110

-

113740

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply, Transportation, laying, testing & commissioning following of 'B' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required Makes : Jindal / Hissar / Tata pipes 80mm dia

150

-

198300

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply, Transportation, laying, testing & commissioning following of 'B' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required Makes : Jindal / Hissar / Tata pipes 100mm dia

135

-

243270

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply, Transportation, laying, testing & commissioning following of 'B' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required Makes : Jindal / Hissar / Tata pipes 150mm dia

40

-

106600

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply, fabricating , installing structural steel supports for fixing all sizes of MS pipes from ceiling / wall with MS Channels, Angles, Flats, Rods, as required at site with anchor fasteners, Clamps, threaded rods, nuts, bolts,washers etc complete with painting

200

-

26800

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25mm dia Gun metal wheel valve, with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required.

4

-

71576

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply, installation, testing and commissioning of 25 / 20mm dia Air Release Valve.

11

-

16082

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supplying, fixing, testing and commissioning of butterfly valve PN 1.6, with Bronze / Gun metal seat duly ISI marked complete with Nuts, Bolts, Washers, gaskets, conforming to IS 13095 of following sizes as required. Makes: Audco / Kirloskar / BDK / H-Shankar / Leader/ Zolotto / Intervalve / Honeywell. 100mm dia

11

-

61171

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply, Transportation, laying, testing & commissioning following of 'B' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required Makes : Jindal / Hissar / Tata pipes 25 mm dia

22

-

9130

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply, Transportation, laying, testing & commissioning following of 'B' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required Makes : Jindal / Hissar / Tata pipes 80 mm dia

22

-

29084

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply, Transportation, laying, testing & commissioning following of 'B' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required Makes : Jindal / Hissar / Tata pipes 100mm dia

50

-

90100

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and fixing First -Aid Hose Reel with MS construction spray painted in Post office Red, Conforming to IS 884 with upto date amendments, complete with the following as required. a) 36.6 Mtr Long 20mm (Nominal internal) dia water hose Thermoplastic / Textile reinforced / Rubber braided / Polypropylene Type - 2 as per IS:12585 Make: Eversafe / Newage / Newtech / SRI b) 20mm (Nominal internal) dia gun metal globe valve and nozzle. Make: Newage / Winco / Padmini / Newtech / Safex. c) Drum and brackets for fixing the equipments on wall. d) Connections from riser with 25mm dia stop valve (gun metal) & MS pipe.

11

-

87923

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and fixing 63mm dia Gun metal branch pipe with 20mm (Nominal internal diameter) size Gun metal conforming to IS 903, suitable for instantaneous connection to interconnect hose pipe coupling as required. Make : Mini Max / Safex / Newage / Winco / Newtech / Padmini.

11

-

30239

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and fixing 63mm dia, 15 mtr long RRL hose pipe with 63mm dia Male and Female Gun metal / SS couplings duly binded with GI wire, rivets etc conforming to IS 636 (Type -A) as required. Make: Mini Max / Safex / Newage / Winco / Newtech / Padmini.

22

-

140734

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supplying and fixing of Hose Cabinet of size 750mm X 600mm x 250mm made of No 16 gauge SWG CRCA sheet with 6mm thick glazed glass door including necessary locking arrangement suitable to accommodate 2 Nos 15 mtr long Hose pipe, 1 No branch pipe, mounted on wall OR raised brick platform and duly painted with Post office red externally and white internally with synthetic enamel paint complete in all respect, for external hydrant as required. Make: Mini Max / Safex / Newage / Winco / Padmini.

11

-

64108

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and fixing single headed internal / External hydrant valve with instantaneous Gunmetal of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required Make: Mini Max / Safex / Newage / Winco / Newtech / Padmini.

11

-

100353

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supplying, installation, commissioning, testing, putting into operation and handing over of 20 Persons Bed cum Passenger Lift (1360 Kgs) with following specifications. The contractor shall produce after sales service support for 2 years during warranty period from the supplier and obtain approval from the engineer-in-charge for making any payment for this. Make : Kone / OTIS / Johnson / Schindler / MITSUBISHI. Make & Model will be Approved by the Head Office / Engineer-in-charge. I) No. of elevators - 1 ii) Type & Capacity : 20 Passenger Bed cum Passenger lift (1360 Kgs) with Gearless with Machine Room. iii ) Speed Approximately : 1.00m/sec iv) Type of Drive: MICRO PROCESSOR BASED VVVF v) Location of Machine Room: Above Lift well vi) Travel : G+2, 11.0 m Approximately. vii) Serving: 3 Stops , 3 Levels and 3 Openings viii) Well Size approximately: 2400 mm wide x 3000 mm deep ix) Power Supply : 415 V, 3 phase 50 Hz, AC x) Auxiliary required: Single Phase 220 V, 50 Hz Ac xi) Car size (clear inside) approx.: 1800 mm wide x 2400 mm deep x 2200 height. xii) Car Enclosure: Stainless Steel Hairline Finish car panels a) Flooring - Aluminium chequered flooring b) Car Illumination : LED Included. xiii) Electric Light/Fan: LED / 400 mm xiv) No. of Entrances: Three at front side. xv) Car Entrance: Stainless Steel Hairline Finish center opening sliding power operated door. xvi) Landing Entrance: Stainless Steel Hairline Finish center opening power door. xvii) Door size : 1200 mm wide x 2000 mm height xviii) Control: Micro Processor based simplex full collective control with or without attendant operation. xix) Indicators: Car & Landings: Dot matrix digital type direction and Position Indicaters with Stainless steel face plates. xx) Other Feature Included: 1.Minor Builders Work 2.Landing Push Button In Landing Door Frames 3.3 Way Intercom / Press And Speak Phone 4.Battery Operated Emergency Light And Alarm Bell 5.Floor Annunciator With Music 6.Automatic Rescue Device 7.Vandal Proof S.S. Button With S.S. Cover 8.Push Button - Orange L E D Illumination 9.Call Register Signal And Vf Door Operator 10.Full Car Operating Panel 11.Dot Matrix Led D & P Indicators In Car & Landings -Orange Colour 12.False Ceiling In Car 13.Firemans Switch 14.Free Service For two Years 15.Infra Red Door Screen 16.Provision For Music 17.Overload Warning Indicator 18. Provision For EPABX 19.Scaffolding 20.SS Handrail 21.Pit Ladder Including Scaffolding, minor building works like chipping, Grouting and pocket cutting.

1

-

2479285

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and Fixing of Condenser stand for Ductable machines etc., complete.

10

-

31810

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply, Installation, Testing and commissioning of fire damper.

30

-

184050

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply, Installation, Testing and commissioning of collar damper.

30

-

96540

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply, Installation, Testing and commissioning of extruded Aluminum powder coated grills/ diffusers for supply with removable core type with volume damper

30

-

269670

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and fixing of 25 mm thickness closed cell nitrile rubber (Class O) insulation on existing duct after applying 2 coats of cold setting adhesive (CPRX Compound). The joints shall be sealed with 50mm wide and 3mm thick self adhesive nitrile rubber tape insulation complete with star bond coating and covered with 24 guage alluminium cladding as per specifications for out door applications.

30

-

57120

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and fixing of 25mm thickness closed cell nitrile rubber (Class O) insulation on existing duct after applying 2 coats of cold setting adhesive (CPRX Compound). The joints shall be sealed with 50mm wide and 3mm thick self adhesive nitrile rubber tape insulation complete as per specifications.

30

-

48540

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply, installation and testing of Canvas connection for the Treated Fresh Air units to the duct & Indoor unit to Ducts

30

-

70890

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply, installation, testing & commissioning of GSS Ducting with required angle flanges & installation materials such as heavy duty supports by anchor fasteners etc as required asper IS 655 /SMACNA Standards. Makes:TATA/Jindal 22 G

50

-

74000

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply, installation, testing & commissioning of GSS Ducting with required angle flanges & installation materials such as heavy duty supports by anchor fasteners etc as required asper IS 655 /SMACNA Standards. Makes:TATA/Jindal 24 G

220

-

269060

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply,errection, testing and commissioning of Fresh air intake GI louvers with bird screen as per standard specifications.

80

-

399920

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Providing 2 runs of 1 1/8" x 5/8" Copper tubes for suction and liquid between indoor and outdoor unit for split/Casseete Air- Conditioner including foaming etc., complete.

200

-

397400

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Errection, Testing and Commissioning of Ductable Split Air Conditioners with intial charging of refrigerant for filling in pipe line Gas and MS structural work for supporting air cooled condensors. on wall / flooring.and PVC drain piping for the units . 5.5 Ton

2

-

19088

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Errection, Testing and Commissioning of Ductable Split Air Conditioners with intial charging of refrigerant for filling in pipe line Gas and MS structural work for supporting air cooled condensors. on wall / flooring.and PVC drain piping for the units . 8.5 Ton

2

-

22724

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Errection, Testing and Commissioning of Ductable Split Air Conditioners with intial charging of refrigerant for filling in pipe line Gas and MS structural work for supporting air cooled condensors. on wall / flooring.and PVC drain piping for the units . 11.0 Ton

3

-

47718

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Ductable Split Airconditioners for ICUs, Pre & Post Operative wards etc. Supply of Ductable Split Airconditioners with scroll compressor (multiple numbers) including electrical panel with scanner for phase sequence under voltage, over and single phase preventor ON/OFF indicators for compressor and initial charges of Refrigerant gas and oil as required. Make : Daikin/ Blue Star / Mitsubhishi/Carrier/ Hitachi. 5.5 Ton

2

-

363568

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Ductable Split Airconditioners for ICUs, Pre & Post Operative wards etc. Supply of Ductable Split Airconditioners with scroll compressor (multiple numbers) including electrical panel with scanner for phase sequence under voltage, over and single phase preventor ON/OFF indicators for compressor and initial charges of Refrigerant gas and oil as required. Make : Daikin/ Blue Star / Mitsubhishi/Carrier/ Hitachi. 8.5 Ton

2

-

558076

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Ductable Split Airconditioners for ICUs, Pre & Post Operative wards etc. Supply of Ductable Split Airconditioners with scroll compressor (multiple numbers) including electrical panel with scanner for phase sequence under voltage, over and single phase preventor ON/OFF indicators for compressor and initial charges of Refrigerant gas and oil as required. Make : Daikin/ Blue Star / Mitsubhishi/Carrier/ Hitachi. 11.0 Ton

3

-

1011627

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and erecting fully automatic line voltage stabilizer for operation on input voltage 200 to 250V. rated for 5 KVA maximum load and time delay model with Volt meter, selector switch, 6A / 16A flush type, 5 pin socket for out put and with 3 core flexible chord and 3 pin 6/16A plug top suitable for refrigerator for continuous operation including cost and conveyance of all mateials and all labour charges etc., complete. Makes : V-Guard / Real Guard / Uni Stab / ITL.

10

-

37880

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and erecting fully automatic line voltage stabilizer for operation on input voltage 200 to 250V. rated for 4 KVA maximum load and time delay model with Volt meter, selector switch, 6A / 16A flush type, 5 pin socket for out put and with 3 core flexible chord and 3 pin 6/16A plug top suitable for refrigerator for continuous operation including cost and conveyance of all mateials and all labour charges etc., complete. Makes : V-Guard / Real Guard / Uni Stab / ITL.

10

-

31800

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply, transportation and installation of split AC unit with high wall mounted 100% copper indoor unit and outdoor condencing unit Hermetically sealed compressor suitable for operation on 230V, 50Hz, 1Phase AC supply capable of performing cooling dehumidifying air circulating and filtering with cooling and condensing units with 3.0 mts of copper piping, insulation kit and 4 mts of 3 core copper flexible chord (Voltage range 160- 264 volts) and cordless remote control with 5 years warranty compressor and comprehensive maintenance for 2 years. 2.0 Ton (2-3 STAR) makes Daikin / Thoshiba / O General / Carrier / Blue Star / Hitachi

10

-

536280

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply, transportation and installation of split AC unit with high wall mounted 100% copper indoor unit and outdoor condencing unit Hermetically sealed compressor suitable for operation on 230V, 50Hz, 1Phase AC supply capable of performing cooling dehumidifying air circulating and filtering with cooling and condensing units with 3.0 mts of copper piping, insulation kit and 4 mts of 3 core copper flexible chord (Voltage range 160- 264 volts) and cordless remote control with 5 years warranty compressor and comprehensive maintenance for 2 years. 1.5 TR 3 Star capable of delivering 18000 BTU/hr Makes: Carrier / Daikin / Blue Star / Hitachi.

10

-

440120

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and transportation & fixing of 72 W +/-10% (>=7200 Lumens) LED Street light Body made of high grade pressure die ? cast Aluminium alloy with corrosion resistant powder coat, having protective toughened glass cover, Suitable lens on LEDs, Less Glare, IP 66 (Silicon gasket ensures Optical & Electrical compartments are IP 66) protected, wide operating voltage range, P.F > 0.90, System having efficacy >110 lumens/watt, with Ingress protection IP66, Potted driver, Driver surge protection >10KV, THD<15%, CCT: 3000- 6500K as desired by the department and as per IS, CRI>70, Inbuilt Electrical protections like Over voltage, short circuit, Over load, Open Circuit, Miswiring, etc complete with BIS certification with 5 years warranty. The contractor has to furnish the manufacturer warranty letter, LM 79 and LM 80 certificates. LUMINAIRE MAKE: PHILIPS / OSRAM / GE Venture / CROMPTON / BAJAJ / Surya / Wipro / Jaquar / HAVELLS / POLYCAB /Goldmedal / HPL LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA / OSRAM / SAMSUNG / LG LEDs.

14

-

90818

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and fixing of Automatic Street Light Control System with Optical Sensor, Low volatage / High voltage trip and reset, operating voltage 380 - 450 V AC, 50 HZ with suitable SMC enclousure of IP 54 protection, MCBs of Legrand / Schneider / L&T / Siemens of 10KA C/D curve and Contactor suitable to control the load of 8 KW Three phase load with necessary clamping arrangements. Makes : Swadeep Nature Switch / Light Mate / L&T / Siemens / Bajaj

1

-

20078

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and fixing of suitable out door feeder piller box of size made with 14 SWG CRCA sheet with double door arrangement, making powder coating after processing of 7 Tank process, lock and key, hinges, rubber gasket, danger board,suitable angle iron stand for mounting the feeder pillar with cement concrete, including Supply and fixing of Legrand / Schnieder make 63A, 4 Pole MCB as incomer, 9 Nos 6-32A SP MCBs as out goings, indication lamps, din channel, 6 Sqmm 3 core copper cable for invidual light control, connectors, bus bars, shroudings, gland plates and provision for 3 phase energy meter etc., complete for finished item of work and suitable wiring provision for connecting the nature switch with following.

1

-

30768

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Foundation and erection charges with special T&P, for 7.50 Mtrs long Octagonal / Conical pole duly erecting on base plate duly providing 4 Nos foundation bolts with nuts with providing of 0.45Mtr x0.45 Mtrs x 1.20 Mtr size M20 cc work vibrated concreting mixing with necessary steel (10kgs) reinforcement as directed by the field engineers during execution including all labour charges and cost and conveyance of materials etc. complete.

12

-

74496

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Fabrication, Transportation and supply of of 1.5mtrs sword type decorative double arm bracket with dooms either sides complete with all accessories with MS galvanized 50mm dia Pipe. Makes: BAJAJ / VALMONT / TRANSRAIL / SKIPPER / LAASMA.

2

-

13404

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Fabrication, Transportation and supply of of 1.5mtrs sword type decorative Single arm bracket with dooms complete with all accessories with MS galvanized 50mm dia Pipe. Makes: BAJAJ / VALMONT / TRANSRAIL / SKIPPER / LAASMA.

12

-

61620

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Fabrication, Transportation and supply of hot-dip galvanized Octogonal Pole with BSEN - 10025 grade S 355 JO steel plate for shaft, IS 2062 for base plate with door opening arrangement, including chain for anti theft mechanism, supply of suitable boards with bakelite sheet, din channel for MCB's as per IS specification suitable to withstand the wind speed of 180 KMPH for 7.50 Mtrs height Pole having dimensions Bottom 130mm, Top 70mm with 3mm thick, base plate 220 x 220 x 12mm and 4 Nos of M20 x 700mm long 'J' bolts along with template or equivalent. Makes: BAJAJ / VALMONT / TRANSRAIL / SKIPPER / LAASMA.

12

-

180372

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and fixing of 8 PoE 1GB ports + 4 Gigabit SFP ports Web Smart Switch. Make: D-Link Model No.DGS1210-8P or its Equivalent make

3

-

69768

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and installation of 4K UHD , 55? LED Display complete Make- Samsung QB55R with following Specifications : a) Diagonal Size 55" b)Type Edge LED BLU. c)Resolution 3840*2160 (4K UHD) d) Pixel Pitch(mm)0.105 x 0.315. e) Active Display Area(mm)1209.6(H) x 680.4(V) f) Brightness(Typ.) 350 nit. g) Contrast Ratio 4000:1.

1

-

90780

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and fixing of Surveillance HDD-4 TB Make-Sea gate/Hitachi/TOSHIBA

1

-

17442

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply, installation,Testing and Comissioning of 32 channel NVR (Network Video Recorder) Max. 12MP Camera supported,256Mbps network camera recording,Support 4K video out on HDMI monitor,Support Dual monitor video out,Support H.265, H.264, MJPEG compression, Wise Stream support, Max. 8 internal HDDs (48TB), e-SATA / iSCSI storage support, Support RAID 5 Easy installation with front swap hard disks ARB & Failover (N+1) support, UL Cerfified NVR. Make:Samsung Model:XRN-2010 or its equivalent Specification of makes Honeywell / Sony /Panasonic.

1

-

180500

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply,Installation,Testing & Commissioining of IP IR Bullet Camera (2 MP Series), 2MP Network IR Bullet Camera 2megapixel (1920 x 1080) resolution,0.1Lux (Color), 0Lux (B/W, IR LED on),2.8mm fixed lens Max. 30fps@2M all resolutions (H.265/H.264) H.265, H.264, MJPEG codec supported, Multiple streaming,Motion detection, Tampering, Defocus detection, Hallway view (90°/270°), LDC support Micro SD/SDHC/SDXC memory slot (Max. 128GB) IR viewable length 20m/25m/ 30m,IP66, IK10, PoE, 12VDC UL Listed Bullet Camera Make: Samsung Model QNO-6012R or its equivalent Specification of makes Honeywell / Sony /Panasonic.

2

-

34884

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply,Installation,Testing & Commissioining of IP IR Dome Camera (2 MP Series), 2MP Network IR Dome Camera Max. 2megapixel (1920 x 1080) resolution,0.095Lux (Color), 0Lux (B/W, IR LED on), 3.2 ~ 10mm (3.1x) varifocal lens,Max. 30fps@2M all resolutions (H.265/H.264)H.265, H.264, MJPEG codec supported, Multiple streaming,Motion detection, Tampering, Defocus detection,Hallway view (90°/270°), LDC support,Micro SD/SDHC/SDXC memory slot (Max. 128GB),IR viewable length 20m,PoE/12VDC UL Certified Dome Camera. Make : Sumsung Model:QND-6072D or its equivalent Specification of Makes Honeywell / Sony /Panasonic.

12

-

209304

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and installation of IP 20, IK 08 42U floor Stand 600mm Width x 800mm Deep Floor mounting net work rack with all accessories like front and rear doors, fans, castors, cable manager, shelf, power distribution unit, hardware packet. Mod cap floor stand : Modular construction of the rack made of 4 vertical , 4 Horizontal and 4 depth alloy extruded multi folded hallow profiles bolted and joined together with links and corner blocks. 3 Pairs of support channels to equate the load evenly and castor provision at bottom side. Painting shade : Combination of RAL 7035 / 7037 fine texture - 60 to 80 microns. or RAL 9005 fine texture - 60 to 80 microns complies with standards : UL 2416, Din 41494, IEC EN 60529, IEC EN 62262, IEC EN 60068-2-11, ISO 9001-2008. Makes : HCL / VAL / Rittal / APW.

1

-

83366

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply, Transportation and Fixing of 19" 12U Wall mounting net work rack with power spike including all accessories and labour charges etc., complete. Makes : HCL / VAL / Rittal / APW.

5

-

52590

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply, Transportation and Fixing of 19" 9U Wall mounting net work rack with power spike including all accessories and labour charges etc., complete. Makes : HCL / VAL / Rittal / APW

4

-

36452

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply, Transportation and Fixing of 24 port patch panels including all accessories and labour charges etc., complete. Makes : D Link / AMP / Molex / Legrand / Krone

10

-

80680

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply, Transportation and Fixing of 24 Port manageble switches including all accessories and labour charges etc., complete. Makes : CISCO / Net Gear / HP / D link

10

-

83310

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply of 3 feet length moulded patch cord. Makes : D Link / AMP / Molex / Legrand / Krone.

130

-

30680

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply of 7 feet length moulded patch cord. Makes : D Link / AMP / Molex / Legrand / Krone.

130

-

34060

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply, Transportation and Fixing of Cat 6 RJ-45 information outlets including duel face plate with all accessories and labour charges etc., complete. Makes : D Link / AMP / Molex / Legrand / Krone.

151

-

80483

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply, Transportation and Run of Cat - 6 UTP cable for LAN in the existing conduit pipe and labour charges etc., complete. Makes : D Link / AMP / Molex / Legrand / Krone.

5450

-

228900

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply, Installation, Testing and Commissioning of IP Based digtal Telephone (EPABX) system--complied with following specifications: > IP @ Core, PCM/TDM switching, Non blocking, > Must Support PRI, E1, Analog Junctions > Must Support PC Console, > Must support Mobile SIP (Android and I O.S) > Must support Voice Mail > Must support Card based GSM > Inbuilt Call Details Software with search engine software > 8 Analog Trunks > 8 Digital Extensions > 96 Analog Extensions > 1 Digital Key Phone with minimum 16 Keys (Must work only on 2 wires) > Expandable to 220 Ports wired or more at extra cost Approved Brands: NEC/ Alcatel/ Karel / Unify

1

-

284717

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply, Transportation and Fixing of 100 pair Telephone distribution box with back mount frame, krone connector, powder coated metal body with lock and key arrangement including all accessories and labour charges etc., complete.

1

-

4994

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply, Transportation and Fixing of 50 pair Telephone distribution box with back mount frame, krone connector, powder coated metal body with lock and key arrangement including all accessories and labour charges etc., complete.

1

-

2817

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply, Transportation and Fixing of 20 pair Telephone distribution box with back mount frame, krone connector, powder coated metal body with lock and key arrangement including all accessories and labour charges etc., complete.

5

-

7090

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply, Transportation and Fixing of 10 pair Telephone distribution box with back mount frame, krone connector, powder coated metal body of best quality and make as directed with lock and key arrangement including all accessories and labour charges etc., complete.

8

-

7856

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply, Transportation and Run of 1 of 50 Pair telephone copper cable in the existing cable tray/ conduit pipe and labour charges etc., complete. Makes :Finolex / Delton / Surabi / Polycab

100

-

24800

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply, Transportation and Run of 1 of 20 Pair telephone copper cable in the existing cable tray/ conduit pipe and labour charges etc., complete. Makes :Finolex / Delton / Surabi / Polycab

1750

-

192500

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply, Transportation and Run of 1 of 10 Pair telephone copper cable in the existing cable tray/ conduit pipe and labour charges etc., complete. Makes :Finolex / Delton / Surabi / Polycab

175

-

11025

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply, Transportation and Run of 5 Pair telephone copper cable in the existing conduit pipe and labour charges etc., complete. Makes :Finolex / Delton / Surabi / Polycab

50

-

2300

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply, Transportation and Run of 1 of 2 Pair 0.5mm telephone copper cable in the existing conduit pipe and labour charges etc., complete. Makes : Finolex / Delton / Surabi / Polycab.

4450

-

111250

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and fixing of Modular telephone Jack with connector on modular box with cover frame in existing consealed pipe wiring including cost and coveyance of all material and all labour charges etc., complete in N.R.B. / R.B. Makes : Legrand Arteor / Schneider Zen celo / Honeywell Blenge Plus / Cabtree Amare / Logus Platina / Gold Medal GIFA / GM-Zenova/ L&T- Englaze

129

-

44763

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and Transportation of Outer dia 63mm and Inner dia 51mm double walled corrugated HDPE duct made as per specification BSEN - 500 86/IS 14930 Part-II etc., of Makes:DURA LINE (Dura Guard) or its equivalent make complete by making trench in all soils and back filling the exacavated earth without stones and making the surface proper with 15cm crown on the top and as directed by the department including cost and conveyance of all materials and labour charges etc., complete.

50

-

18000

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Preparation of Drawings of existing or new installations and obtaining approval from the CEIG complete as per the requirement at site.

1

-

40000

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;First Aid box 18" x 12" x 8" containing material as prescribed by St. John Ambulance brigade OR Indian Red Cross complete as required.

1

-

1636

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Providing & Supply of round bottom G.I sheet bucket of 9 Ltrs. Capacity as per IS:2546 made out of 24 gauge GI sheet with extra handle at bottom duly painted inside and red out side with printed with FIRE Mark for stand and hook and filled with sand and arranged to existing stand or hook.

16

-

5664

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Providing floor mounting stand for keeping 4No of fire bucket 1500mm length, 900mm height made out of 40x40x6mm angle iron welded with 4 hooks and duly painted with one coat of red lead and two coats of enamel paint.

4

-

5776

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Providing & Fixing of Danger Notice Plates of size 250x200mm, shall comply with IS:2551-1982.

15

-

4635

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Providing & Fixing of Shock instrution chart in English / Hindi / Telugu duly framed with front glass.

2

-

1248

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and fixing of PVC synthetic elastomer electrically insulated mat with Class B insulation conforming to IS: 15652-2006 having 2.5mm thickness upto 11KV.

6

-

30708

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply of Rubber hand gloves suitable for 11 KV.

1

-

614

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply , fabrication and transportation of MS channel iron/ angle iron /flats including two coats of alluminium paint and one coat of red oxide paint including all labour charges etc complete.

1000

-

134000

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply, Transportation and Installation of 600mm x 75mm x 2mm thick GI Ladder type cable tray along with required coupler plates, T's, Bends, Reducers, Anchor bolts, nuts, washers and slotted channels / Angle Iron Channels etc complete and the tray should be fitted on the wall / Ceiling etc. complete for finished item of work. Makes: DEC/MNR/ H FAB or equivalent

25

-

31750

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and Installation of 450mm x 50mm x 2mm thick GI perforated cable tray with out cover along with required angle supports, with coupler plates, Anchor bolts and nuts etc complete and the tray should be fitted on the wall / Ceiling etc. complete. Makes: DEC/MNR/ H FAB or equivalent

10

-

13170

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and Installation of 300mm x 50mm x 2mm thick GI perforated cable tray with out cover along with required angle supports, with coupler plates, Anchor bolts and nuts etc complete and the tray should be fitted on the wall / Ceiling etc. complete. Makes: DEC/MNR/ H FAB or equivalent

155

-

172515

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and Installation of 150mm x 50mm x 2mm thick GI perforated cable tray with out cover along with required angle supports, with coupler plates, Anchor bolts and nuts etc complete and the tray should be fitted on the wall / Ceiling etc. complete. Makes: DEC/MNR/ H FAB or equivalent

50

-

40400

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and Installation of 100mm x 25mm x 2mm thick GI perforated cable tray with out cover along with required angle supports, with coupler plates, Anchor bolts and nuts etc complete and the tray should be fitted on the wall / Ceiling etc. complete. Makes: DEC/MNR/ H FAB or equivalent

55

-

26015

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Providing Termination for UG cables for following XLPE insulated armoured cable with fixing of heavy duty type double compression weather proof type brass cable glands duly nickel plated as per BS 6121 and IP66 complete with brass checknut, outer sheath sealing gasket, with required lugs etc complete. Makes: SMI / Commet / Dowels.300 Sqmm 3.5 Core

10

-

31520

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Providing Termination for UG cables for following XLPE insulated armoured cable with fixing of heavy duty type double compression weather proof type brass cable glands duly nickel plated as per BS 6121 and IP66 complete with brass checknut, outer sheath sealing gasket, with required lugs etc complete. Makes: SMI / Commet / Dowels. 240 Sqmm 3.5 Core

4

-

10852

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Providing Termination for UG cables for following XLPE insulated armoured cable with fixing of heavy duty type double compression weather proof type brass cable glands duly nickel plated as per BS 6121 and IP66 complete with brass checknut, outer sheath sealing gasket, with required lugs etc complete. Makes: SMI / Commet / Dowels. 185 Sqmm 3.5 Core

14

-

29316

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Providing Termination for UG cables for following XLPE insulated armoured cable with fixing of heavy duty type double compression weather proof type brass cable glands duly nickel plated as per BS 6121 and IP66 complete with brass checknut, outer sheath sealing gasket, with required lugs etc complete. Makes: SMI / Commet / Dowels. 120 Sqmm 3.5 Core

12

-

19116

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Providing Termination for UG cables for following XLPE insulated armoured cable with fixing of heavy duty type double compression weather proof type brass cable glands duly nickel plated as per BS 6121 and IP66 complete with brass checknut, outer sheath sealing gasket, with required lugs etc complete. Makes: SMI / Commet / Dowels. 95 Sqmm 3.5 Core

16

-

18528

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Providing Termination for UG cables for following XLPE insulated armoured cable with fixing of heavy duty type double compression weather proof type brass cable glands duly nickel plated as per BS 6121 and IP66 complete with brass checknut, outer sheath sealing gasket, with required lugs etc complete. Makes: SMI / Commet / Dowels. 70 Sqmm 3.5 Core

16

-

17728

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Providing Termination for UG cables for following XLPE insulated armoured cable with fixing of heavy duty type double compression weather proof type brass cable glands duly nickel plated as per BS 6121 and IP66 complete with brass checknut, outer sheath sealing gasket, with required lugs etc complete. Makes: SMI / Commet / Dowels. 50 Sqmm 3.5 Core

16

-

12176

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Providing Termination for UG cables for following XLPE insulated armoured cable with fixing of heavy duty type double compression weather proof type brass cable glands duly nickel plated as per BS 6121 and IP66 complete with brass checknut, outer sheath sealing gasket, with required lugs etc complete. Makes: SMI / Commet / Dowels. 35 Sqmm 3.5 Core

14

-

8246

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Providing Termination for UG cables for following XLPE insulated armoured cable with fixing of heavy duty type double compression weather proof type brass cable glands duly nickel plated as per BS 6121 and IP66 complete with brass checknut, outer sheath sealing gasket, with required lugs etc complete. Makes: SMI / Commet / Dowels. 16 Sqmm 4 Core

64

-

29760

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Laying of PVC armoured under ground cable up to 70 Sqmm fixing on chromium plated metallic base saddles on wall / Cable tray as per IS 1255 and as directed by the department including cost and conveyance of all materials and labour charges etc., complete.

630

-

29610

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Laying of PVC armoured under ground cable from 95 Sq.mm to 400 Sqmm fixing on chromium plated metallic base saddles on wall / cable tray as per IS 1255 and as directed by the department including cost and conveyance of all materials and labour charges etc., complete.

60

-

3540

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Earth work excavation of Trench in hard ground soil and Sand filling shall be provided at the bottom of trench before laying the cable and laying of U.G cables covering the cable with back filling of Trench duly providing route indicator embedded in C.C including cost and conveyance of materials and labour charges etc., complete.

330

-

87450

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Earth work excavation of Trench in hard ground soil and Sand filling shall be provided at the bottom of trench before laying the cable and laying of U.G cables from 95 Sqmm up to 400 sqmm covering the cable with bricks and back filling of Trench duly providing route indicator at every 8 Mtrs distance embedded in C.C including cost and conveyance of materials and labour charges etc., complete.

890

-

246530

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply of the Following XLPE insulated, 1100V grade armoured alluminium cable with ISI mark as per specification confirming to IS:7098 (Part - I) Makes : Torrent / Unicab / Universal / Polycab / Havells / Gloster / KEI / Finolex / Payal / RR kable / Finecab / RPG / V - Guard. 300 Sqmm 3.5 Core

500

-

1359500

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply of the Following XLPE insulated, 1100V grade armoured alluminium cable with ISI mark as per specification confirming to IS:7098 (Part - I) Makes : Torrent / Unicab / Universal / Polycab / Havells / Gloster / KEI / Finolex / Payal / RR kable / Finecab / RPG / V - Guard. 240 Sqmm 3.5 Core

200

-

445200

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply of the Following XLPE insulated, 1100V grade armoured alluminium cable with ISI mark as per specification confirming to IS:7098 (Part - I) Makes : Torrent / Unicab / Universal / Polycab / Havells / Gloster / KEI / Finolex / Payal / RR kable / Finecab / RPG / V - Guard. 185 Sqmm 3.5 Core

150

-

263250

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply of the Following XLPE insulated, 1100V grade armoured alluminium cable with ISI mark as per specification confirming to IS:7098 (Part - I) Makes : Torrent / Unicab / Universal / Polycab / Havells / Gloster / KEI / Finolex / Payal / RR kable / Finecab / RPG / V - Guard. 120 Sqmm 3.5 Core

250

-

315500

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply of the Following XLPE insulated, 1100V grade armoured alluminium cable with ISI mark as per specification confirming to IS:7098 (Part - I) Makes : Torrent / Unicab / Universal / Polycab / Havells / Gloster / KEI / Finolex / Payal / RR kable / Finecab / RPG / V - Guard. 95 Sqmm 3.5 Core

250

-

256500

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply of the Following XLPE insulated, 1100V grade armoured alluminium cable with ISI mark as per specification confirming to IS:7098 (Part - I) Makes : Torrent / Unicab / Universal / Polycab / Havells / Gloster / KEI / Finolex / Payal / RR kable / Finecab / RPG / V - Guard. 70 Sqmm 3.5 Core

250

-

197500

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply of the Following XLPE insulated, 1100V grade armoured alluminium cable with ISI mark as per specification confirming to IS:7098 (Part - I) Makes : Torrent / Unicab / Universal / Polycab / Havells / Gloster / KEI / Finolex / Payal / RR kable / Finecab / RPG / V - Guard. 50 Sqmm 3.5 Core

250

-

153250

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply of the Following XLPE insulated, 1100V grade armoured alluminium cable with ISI mark as per specification confirming to IS:7098 (Part - I) Makes : Torrent / Unicab / Universal / Polycab / Havells / Gloster / KEI / Finolex / Payal / RR kable / Finecab / RPG / V - Guard. 35 Sqmm 3.5 Core

250

-

116000

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply of the Following XLPE insulated, 1100V grade armoured alluminium cable with ISI mark as per specification confirming to IS:7098 (Part - I) Makes : Torrent / Unicab / Universal / Polycab / Havells / Gloster / KEI / Finolex / Payal / RR kable / Finecab / RPG / V - Guard. 16 Sqmm 4 Core

700

-

213500

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply & laying of 40mm HBG metal 4" thick in sub-station including cost and conveyance of all material & sand cushioning 2".

10

-

14600

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and fixing of gate fixing frame with size 2.1M x 1.25M width fabricated with MS Angle 40x40x6mm fencing frame and the gate of size 1.8M x 1.25M with Angle 35x35x5mm four sides and 40x40x6mm 'T' Angle in middle & M.S weld mesh 2"x2" including painting.

2

-

10400

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Hot dipped Galvanized Iron Chain link mesh 8 gauge - (4.0 mm) as per IS: 2721-1979: 2"x2"(50mm x 50 mm) - 8Gauge overheads and contractor profit etc., complete for finished item of work.

20

-

32320

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Providing transformer plinth 1.2 x 1.2 x 1.5 mtr in size with necessary excavation in ground at the bottom with 150mm thick 1:2:4 cement concrete raft at the bottom and top and 225mm thick wall constructed in stone masonry and remaking hallow portion shall be filled with stone chips duly plastered 20mm thick outsides including watering etc., complete.

1

-

19728

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Providing of CC foundations suitable for the 250KVA DG se complete as directed and as per the norms with all required hard ware materials complete.

1

-

25000

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply , Fabrication, Transportation and fixing of Box type RS Joist pole made with 2 Nos 175X85 mm ( ISMB Modified ) or equivalent about 30'-0 length / 9.1 mtrs length poles welded together including excavation of pit, coil earthing, Special T&P, painting of Pole with 1 coat of Red oxide and 2 coats of alluminium paint, CC 1:3:6 upto ground and 1:2:4 for Couping work, 200A AB Switch, HG fuse sets, required angle iron channels, clamps, nuts and bolts, 11KV pin insulators, 2Nos GI pipe earthings as per the IS with brick massonry chamber including labour and transportation charges etc., complete.

2

-

199612

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Providing and errecting heat shrinkable indoor termination kit for 11 KV HT XLPE insulated armoured cable 11KV, 3core 95Sqmm with necessary materials etc., complete. Makes : Raychem / Transeal / M Seal

8

-

106880

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply,Providing and errecting heat shrinkable outdoor termination kit for 11 KV HT XLPE insulated armoured cable 11KV, 3core 95Sqmm with necessary materials etc., complete. Makes : Raychem / Transeal / M Seal

8

-

162248

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply of 3 Core 11 KV 95Sqmm HT XLPE (E) armoured Cable, as per IS specification confirming to IS 7098/II/85 with latest ammendments of Makes : Torrent / Unicab / Universal / Polycab / Havells/ KEI / RPG / Gloster.

100

-

171600

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and fixing of 12V 65 AH SMF battery including wire leads. Makes : Quanta / Racket / Exide.

130

-

1137240

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and providing of UPS cum battery rack up to 20 batteries

9

-

51741

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply, Transportation and installation of 10KVA / 312VDCon line UPS system IGBT based rectifier with input power factor correction 32 bit microprocessor based with isolation transformers double conversion, SNMP controls, LCD display, Pure sine wave out put, with auto static switch three phase input / Three phase output and modular structure for better thermal technology / cooling facility, with warranty up to three years. Makes: APC / Numeric / Emerson / Fuji Electric.

5

-

812345

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;DG SET Supply, Transportation, erection and commissioning (Excluding Foundation) of 3 Phase, 415, 50Hz, water cooled multi cylinder diesel generator set with alternator of 250 KVA/200KW out put contineous rating directly coupled Engine and Alternator with guard and mounted on a common base plate of Robust construction and complete with AMF panel having IP-52 protection, Acoustic Enclosure as per CPCB norms , sound absorbing material, t to restrict sound level up to 75 dB up to 1 mtr distance and as per CPCB norms etc. A. Alternator : Kirloskar / Stamford / Crompton Greaves / Leroy Somer make. The alternator of the output rating shall be 3 Phase, 415V, 50Hz, Ac , 0.8 P.F. lagging at 1500 RPM. The alternator is self excited, self regulated, and shall confirm to IS: 13364 of 1992 or latest version with regulation of +5% from no load to full load. degree of protections shall be IP21. B.Diesel Engine : Kirloskar / Cummins / Catterpiller Diesel Engine start, developing suitable 310 BHP output at 1500 RPM with mechanical / electronic governing so as to enable the alternator to give 250KVA continuous output at 0.8 P.F. lagging at NTP conditions. The diesel engine shall be capable of providing 10% O/L for 1 Hr for every 11 Hrs of continuous running at full load. The engine with 1st filling of oil and Diesel etc with standard control panel. 01. Exhaust pipe of required size and length with insulation as per the site condition with alluminium clading. 02. Diesel tank suitable for 8 to 12 Hours running capacity. 03. Residential Silencer. 04. SMF Batteries with leads as per the Manufacturer standards C. AMF Control Panel:- AMF control panel shall be fabricated with 16SWG CRCA sheet shall be totally enclosed with dust and Vermin proof, floor mounted / wall mounted type and shall be comprising the following. 01. Voltmeter with selector switch. 02. 4 Pole MCCB incomer of 800A rating of Schenieder / L&T make for EB and DG . 03. Ammeter with selector switch with CTs. 04. PF Meter and frequency Meter. 05. Indicator lamps (set Run, Load ON) with fuses. 06. KWH Meter of required rating. 07. Set of control fuses and current transformer. 08. Input Terminal board and output Terminal Board. 09. Battery charger with transformer rectifier unit. 10. Alternator supply air break contactor of L&T make. 11. Main supply air break contactor of L&T make. 12. Audio Visual annunciation . 13. Main supply voltage set of control relays and timers with one mode selector switch, set of push buttons. 14.Control cable up to 15 Mtrs 10 Sqmm 6 Core

1

-

2835649

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Transformers Supply and Transportation of 500 KVA Copper Wound Transformer with all test reports. The Transformer shall be designed and manufactured as per IS:1180 OCTC with level - I with initial filling of oil as per IS 335-1993. The basic details of the Transformer are as under. Makes: Kirloskar / PETE / Esennar / Voltamp / Crompton / ABB / Schneider. 1. Quantity : 1 Nos 2.Rated KVA : 500KVA 3. Service & Location: Continuous Outdoor Distribution Transformer 4. Mounting : Plinth. 5. Wound : Copper Double wound 6. Type : Core type oil immersed 7. Cooling : ONAN 8. Temp Rise : 40°C in oil, 45°C by resistance 9. Vector Group: Dyn 11 10. Primary Connection : Delta 11.Nominal Voltage / Current : 11KV/415V,52A/1390A 12. Highest system Voltage: 12000V 13. Primary Frequency :50 HZ +/- 3% 14. Number of Phases : 3 15. Primary wires:3 16. Secondary connection : Star 17. Secondary Volts / Current : 433V 18. Secondary phases : 3 19. Secondary wires: 4 20. Taps on primary winding for primary voltage variation : +5% to - 10% in steps of 2.5% of 7 position (6 Steps) 21. Terminal arrangement. a.HV: HT terminal box as per the site condition. b. LV: Cable box suitable to receive 1600A Air bus duct 22. LV:One separate terminal for earthing. 23. Total Losses at 50% Loading [Watts] [Max] as per IS 24. Total Losses at 100% Loading [Watts] [Max] as per IS 25.Percentage Impedance at 75 deg. C at as per IS 26. No Load current: Less than 2% of full load current. 27. Standrad Fittings & Accessories a. Rating and terminal marking plate: One b. Lifting Lugs:Two c. Off-circuit tap switch :One d. Earthing Terminals :Two e. Radiators ( Attachable):Adequate f. Explosion vent with Diaphragm :One g. Conservator with Drain plug:one h. Oil filling hole with cap :One i. Oil level indicator : One j. Dehydrating Silicagel Breather : One k. Terminal Arrangement: HV With Treminal Box l. Terminal Arrangement : LV Cable Box m. Separate Neutral Bushing : One n. Filter valve with blanking plate : One o. Drain cum filter valve with blanking plate : One p. Air release device : One q. Thermometer Pocket : One r. Four :Unidirectional flat rollers s. One :10Cm dial thermometer(Rigid stem type)

2

-

3414354

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;VCB 3 Panel Supply, Installation, Testing and commissioning of indoor type floor mounted metal clad VCB panel with 3 Nos VCBs, totally enclosed and fully inter locked horizantal draw out, horizantal isolated type breaker as per IS 13118 Specifications and as amended upto date and additional specifications, having capacities mentioned below, single break, trip free mechanism, motorised operated spring / manually charged and auto/manually closed breaker suitable for use on 11KV, 3 Phase, 50 HZ AC supply with short circuit fault level of 350 / 500 MVA, complete with self contained, fully inter locked rack in and rack out mechanism, air insulated but encapsulated copper bus bars of 630A capacity, breaker featured with mechanical ON/OFF indicator with hand trip device, spring charging motor, 110V DC closing and tripping coil, safety shutter assembly, shunt trip coil and auxilary switch of 4 NO + 4 NC and equipped with the following switchgears and accessories including connections suitable for XLPE 11 KV cable, cable entry from bottom, end termination with heat shrinkable jointing material etc as required including construction of suitable CC works for VCB's etc complete. Makes:Kirloskar / Schneider / Siemens / ABB INCOMER - 1 No Vaccum circuit breaker electrical drawout type TP 11 KV 630 A not less than 16 KA rated short circuit rating current -1No POTENTIAL TRANSFORMER:1 No. 11000 / 110 Volts PT, Class 1 accuracy, 100 VA burden with HT/LT fuses. CURRENT TRANSFORMER: 3 Nos epoxy resin cast CTs of ratio 50 -- 300 A / 5A, 15VA burden and accuracy class 1.0 for metering and class 5P10 for protection METERING 1No Digital type Ammeter and selector switch of makes CONZERV/EQVT 1 No digital type Voltmeter with 0-15KV range, slector switch for Voltmeter of makes CONZERV/EQVT 1No Digital Multifunction meter of makes CONZERV/EQVT Heater ON/OFF switch with space heater and thermostat, single phase switch with socket cubical lamp for panel illunmination with door limit switch ,MCB's for AC & DC control. LED indication lamps for breaker on, breaker off, spring charge indication, trip ciruit healthy with push button, Auto trip indication meter, Auxilary contact for service test position (4No + 4 NC) service and test positions and R/Y/B indication lamps. PROTECTION: 1 Nos. Microprocessor based IDMTL 3 over current and 1 earth fault relay with Over current, earth fault and short circuit protection. High speed tripping relay ANNUNCIATION: 8 Window annunciation panel with push buttons and hooters. POWER PACK: Supply, Installation, testing and commissioning of Power pack with 230V input and 110V DC continuous output suitable for closing / tripping / indication of 3 Nos VCBs with 2.5sqmm FRLS copper cable etc as required. OUTGOINGS - 2 Nos 630A VCBs draw out type TP 11 KV 630 A not less than 16 KA rated short circuit rating current. Each breaker shall consist the following. CURRENT TRANSFORMER: Epoxy resin cast CTs of ratio 50 -- 300 A / 5A, 15VA burden and accuracy class 1.0 for metering and class 5P10 for protection - 3 Nos Digital type Ammeter and selector switch - 1 No Makes : CONZERV / EQVT Digital Multifunction meter - 1 No Makes: CONZERV / EQVT PROTECTION : Microprocessor based IDMTL 3 over current and 1 earth fault relay with Over current, earth fault and short circuit protection - 1 No High speed tripping relay Auxiliary relay for bucholz A/T,OTI A/T, WTI A/T Heater ON/OFF switch with space heater and thermostat, single phase switch with socket cubical lamp for panel illunmination with door limit switch,MCB's for AC & DC control. INDICATION LAMPS: LED indication lamps for breaker on, breaker off, spring charge indication, trip ciruit healthy with push button, Auto trip indication meter, Auxilary contact for service test position ( 4No+ 4 NC) service and test positions and R/Y/B indication lamps. ANNUNCIATION: 8 Window annunciation panel with push buttons and hooters. 1 No. rear entry cable box suitable to receive 11 KV, 1 run of 3CX 120 sqmm cable(XLPE) . 1 set of misc items like control fuses, control wiring , inter connections, nuts, bolts, bus trunking including all connected accessories etc. 1 Set of 11 KV, 630A, 350 / 500 MVA alluminium Bus Bar.

1

-

1746609

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;HVAC Panel Supply installation testing and commissioning of 3 phase and neutral 415V free standing floor mounted Out door Type MV panel made out of No.16/14 gauge CRCA sheet steel after 7 tank process and painting with powder coating. The panel shall consists of suitable rating TPN Alluminium busbar ( with rating of 0.8A/ Sqmm)supported with DMC /SMC barriers and colour coaded with heat shrinkable sleeves, flexibiltioy to accept the up four out going cables and necessary cable chamber . The panel shall have comprised of following switch gear . Including supply and fixing the same and painting with powder coating including internal connections cost and conveyance of all materials & labour charges. 250A 4 Pole MCCB, Adjustable, Confirms to IS/IEC 60947-2 having Breaking Capacity 36/35 KA with thermal magnetic release Panel Mounted as incomer. Makes : L&T- D shine / Schneider-NS NSX / Legrand -DP X3 / Siemens-3VL / Hagerh3 / C&S -Winbreak - 1 No. 125A 3 Pole MCCB, Adjustable, Confirms to IS/IEC 60947-2 having Breaking Capacity 25 KA with thermal magnetic release Panel Mounted Makes : L&T- D shine / Schneider-NS NSX / Legrand -DP X3 / Siemens-3VL / Hagerh3 / C&S -Winbreak - 2 Nos 63A / 60A 3 Pole MCCB, Adjustable, Confirms to IS/IEC 60947-2 having Breaking Capacity 25 KA with thermal magnetic release Panel Mounted. Makes : L&T- D shine / Schneider-NS NSX / Legrand -DP X3 / Siemens-3VL / Hagerh3 / C&S -Winbreak - 8 Nos. 0-415V volt Digital meter of size 96x96mm on exisiting box / panel board including connections etc., complete of CONZERVE / ELMEASURE / MECO / HPL MAKE. - 1 No. 0-100 / 200 / 400 / 600 /1000 - 5A CT Digital Ammeter of size 96x96mm on existing box / panel board including connections etc., complete of CONZERVE / ELMEASURE / MECO / HPL MAKE. - 1 No. Analog selector switch for voltmeter / Ammeter on the existing box / panel including connections etc., complete. L&T / C&S / SALZAR / HPL MAKE. - 2 Nos Analog LED indicator lamps on the existing box / panel board.L&T / C&S / SALZAR / HPL MAKE. - 3 Nos. Multifunction energy meter Class I RS 485 with LED display. - 1No Analog LT current transformer with bar primary 100/5A to 1000 / 5A ratio in the existing box / panel including connections etc., complete. KAPPA MAKE. - 3 Nos. Labour charges etc complete with connections for Finished item of work.

1

-

327163

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Utility Panel Supply installation testing and commissioning of 3 phase and neutral 415V free standing floor mounted Out door Type MV panel made out of No.16/14 gauge CRCA sheet steel after 7 tank process and painting with powder coating. The panel shall consists of suitable rating TPN Alluminium busbar ( with rating of 0.8A/ Sqmm)supported with DMC /SMC barriers and colour coaded with heat shrinkable sleeves, flexibiltioy to accept the up four out going cables and necessary cable chamber . The panel shall have comprised of following switch gear . Including supply and fixing the same and painting with powder coating including internal connections cost and conveyance of all materials & labour charges. Incomer : 250A 4P MCCB, Adjustable, Confirms to IS/IEC 60947-2 having Breaking Capacity 35 KA with thermal magnetic release Panel Mounted as incomer.Makes : L&T- D shine / Schneider-NS NSX / Legrand -DP X3 / Siemens-3VL / Hagerh3 / C&S -Winbreak - 1 No. 125A 3 Pole MCCB, Adjustable, Confirms to IS/IEC 60947-2 having Breaking Capacity 25 KA with thermal magnetic release Panel Mounted Makes : L&T- D shine / Schneider-NS NSX / Legrand -DP X3 / Siemens-3VL / Hagerh3 / C&S -Winbreak - 4Nos 63A / 60A 3 Pole MCCB, Adjustable, Confirms to IS/IEC 60947-2 having Breaking Capacity 25 KA with thermal magnetic release Panel Mounted.Makes : L&T- D shine / Schneider-NS NSX / Legrand -DP X3 / Siemens-3VL / Hagerh3 / C&S -Winbreak - 4 Nos. 0-415V volt Digital meter of size 96x96mm on exisiting box / panel board including connections etc., complete of CONZERVE / ELMEASURE / MECO / HPL MAKE. - 1 No. 0-100 / 200 / 400 / 600 /1000 - 5A CT Digital Ammeter of size 96x96mm on existing box / panel board including connections etc., complete of CONZERVE / ELMEASURE / MECO / HPL MAKE. - 1 No. Analog selector switch for voltmeter / Ammeter on the existing box / panel including connections etc., complete. L&T / C&S / SALZAR / HPL MAKE. - 2 Nos Analog LED indicator lamps on the existing box / panel board.L&T / C&S / SALZAR / HPL MAKE. - 3 Nos. Multifunction energy meter Class I RS 485 with LED display. - 1No Analog LT current transformer with bar primary 100/5A to 1000 / 5A ratio in the existing box / panel including connections etc., complete. KAPPA MAKE. - 3 Nos. Labour charges etc complete with connections for Finished item of work.

1

-

308841

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Floor Lighting Panel Supply installation testing and commissioning of 3 phase and neutral 415V free standing floor mounted Out door Type MV panel made out of No.16/14 gauge CRCA sheet steel after 7 tank process and painting with powder coating. The panel shall consists of suitable rating TPN Alluminium busbar ( with rating of 0.8A/ Sqmm)supported with DMC /SMC barriers and colour coaded with heat shrinkable sleeves, flexibiltioy to accept the up four out going cables and necessary cable chamber . The panel shall have comprised of following switch gear . Including supply and fixing the same and painting with powder coating including internal connections cost and conveyance of all materials & labour charges. 160A 4 Pole MCCB, Adjustable, Confirms to IS/IEC 60947-2 having Breaking Capacity 25 KA with thermal magnetic release Panel Mounted as incomer.Makes : L&T- D shine / Schneider-NS NSX / Legrand -DP X3 / Siemens-3VL / Hagerh3 / C&S -Winbreak - 1 No. 125A 3 Pole MCCB, Adjustable, Confirms to IS/IEC 60947-2 having Breaking Capacity 25 KA with thermal magnetic release Panel Mounted Makes : L&T- D shine / Schneider-NS NSX / Legrand -DP X3 / Siemens-3VL / Hagerh3 / C&S -Winbreak - 4 Nos 63A / 60A 3 Pole MCCB, Adjustable, Confirms to IS/IEC 60947-2 having Breaking Capacity 16 KA with thermal magnetic release Panel Mounted.Makes : L&T- D shine / Schneider-NS NSX / Legrand -DP X3 / Siemens-3VL / Hagerh3 / C&S -Winbreak - 2 Nos. 40/63 A 10KA TP MCB, C/D Curve ISI Mark Makes : Legrand-DX3 / Shneider-Acti9. - 12 Nos. 0-415V volt Digital meter of size 96x96mm on exisiting box / panel board including connections etc., complete of CONZERVE / ELMEASURE / MECO / HPL MAKE. - 1 No. 0-100 / 200 / 400 / 600 /1000 - 5A CT Digital Ammeter of size 96x96mm on existing box / panel board including connections etc., complete of CONZERVE / ELMEASURE / MECO / HPL MAKE. - 1 No. Analog selector switch for voltmeter / Ammeter on the existing box / panel including connections etc., complete. L&T / C&S / SALZAR / HPL MAKE. - 2 Nos Analog LED indicator lamps on the existing box / panel board.L&T / C&S / SALZAR / HPL MAKE. - 3 Nos. Multifunction energy meter Class I RS 485 with LED display. - 1No Analog LT current transformer with bar primary 100/5A to 1000 / 5A ratio in the existing box / panel including connections etc., complete. KAPPA MAKE. - 3 Nos. Labour charges etc complete with connections for Finished item of work.

6

-

1789296

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Floor Power panel Supply installation testing and commissioning of 3 phase and neutral 415V free standing floor mounted Out door Type MV panel made out of No.16/14 gauge CRCA sheet steel after 7 tank process and painting with powder coating. The panel shall consists of suitable rating TPN Alluminium busbar ( with rating of 0.8A/ Sqmm)supported with DMC /SMC barriers and colour coaded with heat shrinkable sleeves, flexibiltioy to accept the up four out going cables and necessary cable chamber . The panel shall have comprised of following switch gear . Including supply and fixing the same and painting with powder coating including internal connections cost and conveyance of all materials & labour charges. Incomer : 250A 4 Pole MCCB, Adjustable, Confirms to IS/IEC 60947-2 having Breaking Capacity 36/35 KA with thermal magnetic release Panel Mounted as incomer.Makes : L&T- D shine / Schneider-NS NSX / Legrand -DP X3 / Siemens-3VL / Hagerh3 / C&S -Winbreak - 1 No. Out goings 125A 3Pole MCCB, Adjustable, Confirms to IS/IEC 60947-2 having Breaking Capacity 25 KA with thermal magnetic release Panel Mounted Makes : L&T- D shine / Schneider-NS NSX / Legrand -DP X3 / Siemens-3VL / Hagerh3 / C&S -Winbreak -4 Nos 63A / 60A 3Pole MCCB, Adjustable, Confirms to IS/IEC 60947-2 having Breaking Capacity 25 KA with thermal magnetic release Panel Mounted.Makes : L&T- D shine / Schneider-NS NSX / Legrand -DP X3 / Siemens-3VL / Hagerh3 / C&S -Winbreak - 2 Nos. 63 A 10KA TP MCB, C/D Curve ISI Mark Makes : Legrand-DX3 / Shneider-Acti9. - 12 Nos. 0-415V volt Digital meter of size 96x96mm on exisiting box / panel board including connections etc., complete of CONZERVE / ELMEASURE / MECO / HPL MAKE. - 1 No. 0-100 / 200 / 400 / 600 /1000 - 5A CT Digital Ammeter of size 96x96mm on existing box / panel board including connections etc., complete of CONZERVE / ELMEASURE / MECO / HPL MAKE. - 1 No. Analog selector switch for voltmeter / Ammeter on the existing box / panel including connections etc., complete. L&T / C&S / SALZAR / HPL MAKE. - 2 Nos Analog LED indicator lamps on the existing box / panel board.L&T / C&S / SALZAR / HPL MAKE. - 3 Nos. Multifunction energy meter Class I RS 485 with LED display. - 1No Analog LT current transformer with bar primary 100/5A to 1000 / 5A ratio in the existing box / panel including connections etc., complete. KAPPA MAKE. - 3 Nos. Labour charges etc complete with connections for Finished item of work.

6

-

1882530

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Main Lighting Panels in Hospital building Supply installation testing and commissioning of 3 phase and neutral 415V free standing floor mounted Out door Type MV panel made out of No.16/14 gauge CRCA sheet steel after 7 tank process and painting with powder coating. The panel shall consists of suitable rating TPN Alluminium busbar ( with rating of 0.8A/ Sqmm)supported with DMC /SMC barriers and colour coaded with heat shrinkable sleeves, flexibiltioy to accept the up four out going cables and necessary cable chamber . The panel shall have comprised of following switch gear . Including supply and fixing the same and painting with powder coating including internal connections cost and conveyance of all materials & labour charges. Incommer:- 400A 4Pole MCCB, Adjustable, Confirms to IS/IEC 60947-2 having Breaking Capacity 36 KA with thermal magnetic release Panel Mounted. Makes : Makes : L&T- D shine / Schneider-NS NSX / Legrand -DP X3 / Siemens-3VL / Hagerh3 / C&S -Winbreak - 1Nos Out goings:- 250A 3Pole MCCB, Adjustable, Confirms to IS/IEC 60947-2 having Breaking Capacity 35/36 KA with thermal magnetic release Panel Mounted. Makes : Makes : L&T- D shine / Schneider-NS NSX / Legrand -DP X3 / Siemens-3VL / Hagerh3 / C&S -Winbreak - 6 Nos 160A 3Pole MCCB, Adjustable, Confirms to IS/IEC 60947-2 having Breaking Capacity 25 KA with thermal magnetic release Panel Mounted. Makes : Makes : L&T- D shine / Schneider-NS NSX / Legrand -DP X3 / Siemens-3VL / Hagerh3 / C&S -Winbreak - 8Nos 125A 3Pole MCCB, Adjustable, Confirms to IS/IEC 60947-2 having Breaking Capacity 25 KA with thermal magnetic release Panel Mounted. Makes : Makes : L&T- D shine / Schneider-NS NSX / Legrand -DP X3 / Siemens-3VL / Hagerh3 / C&S -Winbreak - 2Nos 0-415V volt Digital meter of size 96x96mm on exisiting box / panel board including connections etc., complete of CONZERVE / ELMEASURE / MECO / HPL MAKE. - 1 No. 0-100 / 200 / 400 / 600 /1600 - 5A CT Digital Ammeter of size 96x96mm on existing box / panel board including connections etc., complete of CONZERVE / ELMEASURE / MECO / HPL MAKE. - 1 No. L.T. 3phase Digital multifunction energy meter Class I RS 485 with LED display for measuring all the parameters (Voltage, Current, Frequency, Power factor, KW, KVA, KWH, KVA, KVAH, KVAR and THD Events) on existing box panel board including connections etc., complete.MAKES : CONZERVE / ELMEASURE / L&T / SEIMENS.- 1Nos Analog selector switch for voltmeter / Ammeter on the existing box / panel including connections etc., complete. L&T / C&S / SALZAR / HPL MAKE. - 2 Nos Analog LED indicator lamps on the existing box / panel board.L&T / C&S / SALZAR / HPL MAKE. - 3 Nos. Multifunction energy meter Class I RS 485 with LED display. - 1No Analog LT current transformer with bar primary 100/5A to 1600 / 5A ratio in the existing box / panel including connections etc., complete. KAPPA MAKE. - 3 Nos. Labour charges etc complete with connections for Finished item of work.

1

-

563043

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Main Power Panel in Hospital Building Supply installation testing and commissioning of 3 phase and neutral 415V free standing floor mounted Out door Type MV panel made out of No.16/14 gauge CRCA sheet steel after 7 tank process and painting with powder coating. The panel shall consists of suitable rating TPN Alluminium busbar ( with rating of 0.8A/ Sqmm)supported with DMC /SMC barriers and colour coaded with heat shrinkable sleeves, flexibiltioy to accept the up four out going cables and necessary cable chamber . The panel shall have comprised of following switch gear . Including supply and fixing the same and painting with powder coating including internal connections cost and conveyance of all materials & labour charges. Incommer:- 630A 4Pole MCCB, Adjustable, Confirms to IS/IEC 60947-2 having Breaking Capacity 50 KA with thermal magnetic release Panel Mounted. Makes : Makes : L&T- D shine / Schneider-NS NSX / Legrand -DP X3 / Siemens-3VL / Hagerh3 / C&S -Winbreak - 1 Nos. Out goings:- 400A 3Pole MCCB, Adjustable, Confirms to IS/IEC 60947-2 having Breaking Capacity 36 KA with thermal magnetic release Panel Mounted. Makes :Makes : L&T- D shine / Schneider-NS NSX / Legrand -DP X3 / Siemens-3VL / Hagerh3 / C&S -Winbreak - 6 Nos 250A 3Pole MCCB, Adjustable, Confirms to IS/IEC 60947-2 having Breaking Capacity 36 KA with thermal magnetic release Panel Mounted. Makes : Makes : L&T- D shine / Schneider-NS NSX / Legrand -DP X3 / Siemens-3VL / Hagerh3 / C&S -Winbreak - 6 Nos 125A 3Pole MCCB, Adjustable, Confirms to IS/IEC 60947-2 having Breaking Capacity 25 KA with thermal magnetic release Panel Mounted. Makes : Makes : L&T- D shine / Schneider-NS NSX / Legrand -DP X3 / Siemens-3VL / Hagerh3 / C&S -Winbreak .- 4 Nos 0-415V volt Digital meter of size 96x96mm on exisiting box / panel board including connections etc., complete of CONZERVE / ELMEASURE / MECO / HPL MAKE. - 1 No. 0-100 / 200 / 400 / 600 /1600 - 5A CT Digital Ammeter of size 96x96mm on existing box / panel board including connections etc., complete of CONZERVE / ELMEASURE / MECO / HPL MAKE. - 1 No. L.T. 3phase Digital multifunction energy meter Class I RS 485 with LED display for measuring all the parameters (Voltage, Current, Frequency, Power factor, KW, KVA, KWH, KVA, KVAH, KVAR and THD Events) on existing box panel board including connections etc., complete.MAKES : CONZERVE / ELMEASURE / L&T / SEIMENS.- 1Nos Analog selector switch for voltmeter / Ammeter on the existing box / panel including connections etc., complete. L&T / C&S / SALZAR / HPL MAKE. - 2 Nos Analog LED indicator lamps on the existing box / panel board.L&T / C&S / SALZAR / HPL MAKE. - 3 Nos. Multifunction energy meter Class I RS 485 with LED display. - 1No Analog LT current transformer with bar primary 100/5A to 1600 / 5A ratio in the existing box / panel including connections etc., complete. KAPPA MAKE. - 3 Nos. Labour charges etc complete with connections for Finished item of work.

1

-

785777

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;APFCR panel for 165KVAR in sub-station Supply installation testing and commissioning of 3 phase and neutral 415V free standing floor mounted Out door Type MV panel made out of No.16/14 gauge CRCA sheet steel after 7 tank process and painting with powder coating. The panel shall consists of suitable rating TPN Alluminium busbar ( with rating of 0.8A/ Sqmm)supported with DMC /SMC barriers and colour coaded with heat shrinkable sleeves, flexibiltioy to accept the up four out going cables and necessary cable chamber . The panel shall have comprised of following switch gear . Including supply and fixing the same and painting with powder coating including internal connections cost and conveyance of all materials & labour charges. 250A 4 Pole MCCB, Adjustable, Confirms to IS/IEC 60947-2 having Breaking Capacity 35 / 36 KA with thermal magnetic release Panel Mounted. Makes : L&T- D shine / Schneider-NS NSX / Legrand -DP X3 / Siemens-3VL / Hagerh3 / C&S -Winbreak - 1 No. 63A 3 Pole MCCB, Adjustable, Confirms to IS/IEC 60947-2 having Breaking Capacity 25 KA with thermal magnetic release Panel Mounted.Makes : L&T- D shine / Schneider-NS NSX / Legrand -DP X3 / Siemens-3VL / Hagerh3 / C&S -Winbreak - 8 No. 63A 10KA TP MCB, C/D Curve ISI Mark Makes : Legrand-DX3 / Shneider-Acti9. - 1 Nos. 25 KVAR Capacitor Duty contactors Makes : L&T / Siemens / EPCOS / Meher. - 2 Nos. 15 KVAR Capacitor Duty contactors Makes : L&T / Siemens / EPCOS / Meher. - 4 Nos. 10 KVAR Capacitor Duty contactors Makes : L&T / Siemens / EPCOS / Meher. - 4 Nos. 5 KVAR Capacitor Duty contactors Makes : L&T / Siemens / EPCOS / Meher. - 3 Nos. Supply and fixing of 12Stage APFC Relay with connection etc complete. Makes : L&T / Siemens / EPCOS / Schneider / Elmeasure MPP type heavy duty capacitor of operating voltage not less than 480V and losses not more than 0.35W per KVAR and inrush current withstand capability 300 times the rated current with respective rated capacitor duty contactors Makes:L&T/Siemens/Schneider/Epcos. - 0-415V volt Digital meter of size 96x96mm on exisiting box / panel board including connections etc., complete of CONZERVE / ELMEASURE / MECO / HPL MAKE. - 1 No. 0-100 / 200 / 400 / 600 /1000 - 5A CT Digital Ammeter of size 96x96mm on existing box / panel board including connections etc., complete of CONZERVE / ELMEASURE / MECO / HPL MAKE. - 1 No. Analog selector switch for voltmeter / Ammeter on the existing box / panel including connections etc., complete. L&T / C&S / SALZAR / HPL MAKE. - 2 Nos push buttons on the existing panel board .L&T / C&S / SALZAR / HPL MAKE. - 16Nos. Analog LED indicator lamps on the existing box / panel board.L&T / C&S / SALZAR / HPL MAKE. - 24 Nos. Multifunction energy meter Class I RS 485 with LED display. - 1No Analog LT current transformer with bar primary 100/5A to 1000 / 5A ratio in the existing box / panel including connections etc., complete. KAPPA MAKE. - 3 Nos. Labour charges etc complete with connections for Finished item of work.

1

-

494383

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;MPCC for Hospital in Sub-station Supply installation testing and commissioning of 3 phase and neutral 415V free standing floor mounted Out door Type MV panel made out of No.16/14 gauge CRCA sheet steel after 7 tank process and painting with powder coating. The panel shall consists of suitable rating TPN Alluminium busbar ( with rating of 0.8A/ Sqmm)supported with DMC /SMC barriers and colour coaded with heat shrinkable sleeves, flexibiltioy to accept the up four out going cables and necessary cable chamber . The panel shall have comprised of following switch gear . Including supply and fixing the same and painting with powder coating including internal connections cost and conveyance of all materials & labour charges. Incommer :- 800A 4 Pole, 50kA Air Circuit Breaker electrically drawout Confirms to IS 13947-2, IEC 60947-2 and BS-EN 60947 with Micro processer based having over load, shot circuit and earth fault protection of Makes : Siemens (Sentron- 3WL) / L&T U Power / Schneider Master Pact / ABB Emax / C&S.Winmaster2 / Legrand DMX3 as incomers. - 3 Nos. Out goings:- Supply of 630A 3 Pole MCCB, Adjustable, Confirms to IS/IEC 60947-2 having Breaking Capacity 50 KA with thermal magnetic release Panel Mounted.Makes : L&T- D shine / Schneider-NS NSX / Legrand -DP X3 / Siemens-3VL / Hagerh3 / C&S -Winbreak. - 4 Nos Supply of 400A 3 Pole MCCB, Adjustable, Confirms to IS/IEC 60947-2 having Breaking Capacity 36/35 KA with thermal magnetic release Panel Mounted.Makes : L&T- D shine / Schneider-NS NSX / Legrand -DP X3 / Siemens-3VL / Hagerh3 / C&S -Winbreak. - 4 Nos Supply of 250A 3 Pole MCCB, Adjustable, Confirms to IS/IEC 60947-2 having Breaking Capacity 36/35 KA with thermal magnetic release Panel Mounted.Makes : L&T- D shine / Schneider-NS NSX / Legrand -DP X3 / Siemens-3VL / Hagerh3 / C&S -Winbreak - 4 Nos Supply of 125A 3 Pole MCCB, Adjustable, Confirms to IS/IEC 60947-2 having Breaking Capacity 25KA with thermal magnetic release Panel Mounted.Makes : L&T- D shine / Schneider-NS NSX / Legrand -DP X3 / Siemens-3VL / Hagerh3 / C&S -Winbreak - 4 Nos 0-415V volt Digital meter of size 96x96mm on exisiting box / panel board including connections etc., complete of CONZERVE / ELMEASURE / MECO / HPL MAKE. - 1 No. 0-100 / 200 / 400 / 600 /1600 - 5A CT Digital Ammeter of size 96x96mm on existing box / panel board including connections etc., complete of CONZERVE / ELMEASURE / MECO / HPL MAKE. -1 No. L.T. 3phase Digital multifunction energy meter Class I RS 485 with LED display for measuring all the parameters (Voltage, Current, Frequency, Power factor, KW, KVA, KWH, KVA, KVAH, KVAR and THD Events) on existing box panel board including connections etc., complete.MAKES : CONZERVE / ELMEASURE / L&T / SEIMENS.- 1Nos Analog selector switch for voltmeter / Ammeter on the existing box / panel including connections etc., complete. L&T / C&S / SALZAR / HPL MAKE. - 2 Nos Analog LED indicator lamps on the existing box / panel board.L&T / C&S / SALZAR / HPL MAKE. - 3 Nos. Multifunction energy meter Class I RS 485 with LED display. - 1No Analog LT current transformer with bar primary 100/5A to 1600 / 5A ratio in the existing box / panel including connections etc., complete. KAPPA MAKE. - 3 Nos. Labour charges etc complete with connections for Finished item of work.

1

-

1826624

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply, transportation and fixing of 10W, 1000 lumens, 600mm length LED batten tube light, housing made with PC body, wide operating voltage with Single / double side connection, PF=0.9, Surge protection: > 2KV, THD<15%, with inbuilt driver and frosted cover CCT: 3000K - 6500K as desired by the department and as per IS specifications, minimum CRI=80,.etc complete with 5 years warranty with BIS Certification. LUMINAIRE MAKE: Phillips / OSRAM / GE Venture / Wipro / Crompton / Bajaj / Havells / Jaquar / Panasonic / Halonix / HPL. LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA / OSRAM / SAMSUNG / LG LEDs.

38

-

24662

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and fixing of louver shutter suitable for 12" Exhaust fan including all labour charges etc complete with connections and colouring matching to the wall with enamel paint.

91

-

17472

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Labour charges for fixing of Exhaust fan in wall with necessary connections and masonary work including material of making hole, finishing etc., complete.

91

-

72254

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply,Transportation of 12" (300mm) ISI, 900 RPM Heavy duty exhaust fan with metallic blades wiremesh with all accessories etc complete. Makes : Crompton / Almounard / Havells Turbo Force.

47

-

173383

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply,Transportation of light duty exhaust fan 12"(300 mm) size 900 rpm with metal blades wiremesh with all accessories etc complete. Makes : Crompton / Bajaj Bahar WG / Havells Ventil Air-DB / Orient hill air.

44

-

82368

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and erecting 19/20mm steel tube down rod of one meter length with bolts & nuts duly painted with matching colour of fan complete.

246

-

40344

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Labour charges for Fixing of Ceiling fan including giving connections with twin core wire etc., complete.

291

-

53835

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and fixing of Modular type Stepped electronic regulator for sweep AC ceiling fans of 1200mm / 1400mm complete with connections. Makes : Legrand Arteor / Schneider Zen celo / Honeywell Blenge Plus / Crabtree Amare / Logus Platina / Gold Medal GIFA / GM-Zenova/ L&T Englaze.

291

-

204573

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply, Transportation of energy efficient decorative fan, 1200 mm sweep, aluminium body, consuming 28 W, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) motor, class of insulation: B, 3 no's blades, 30 cm long down rod, 2 no's canopies, shackle kit, safety rope, copper winding, Power Factor greater than 0.90, Service Value (CMM/W) greater than 8.5, Air delivery minimum 235 CMM, 350 RPM (tolerance as per IS:374-2019), THD less than 10%, remote or compatible to electronic step type regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise = 75 degree C (max), insulation resistance more than 2 mega ohm, suitable for 230V, 50 HZ, single phase AC supply, earthing etc., complete. Makes : Atomberg (Efficio + ) / Havells / Orient / RR / Halonix Make & Model will be Approved by the Head Office / Engineer-in-charge.

291

-

1011807

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and fixing of Electronic Musical bell on 4"x7" decolam block including giving connections, cost of all accessories and labour charges etc., complete. Makes : GM / Million / Gold Medal

2

-

808

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and fixing of Buzzer Calling Bell of on 4"x7" decolam block including giving connections, cost of all accessories and labour charges etc., complete. Makes : GM / Million / Gold Medal

14

-

2254

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply, transportation and fixing ISI mark batten holder / slanting holder Makes : Anchor / Gold Medal Olive / Million Zoom in lieu of ceiling rose of light point complete with all connections and all labour charges with 5W LED Lamp. LED Lamp MAKES: Phillips / OSRAM / Crompton / Eveready / Bajaj / Havells / Halonix / Jaquar / C&S / GM / Gold Medal / Million / Syska. Make & Model will be Approved by the Head Office / Engineer-in-charge.

171

-

26676

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply, Transportation and fixing of 60 W +/-10% (>6000 Lumens) LED HIgh Bay Luminaire with high power COB LED made of pressure diecast alluminium housing with powder coated,Supply Input voltage 120 - 270 V AC, P.F > 0.90, high power LED's, System efficacy >100 lm / W and junction temprature < 70°C, with Ingrees protection IP65, IK05, Driver surge protection 4KV, external Surge protection = 5KV with wide/ Narrow beam optics, THD<10% at 110 Volts AC, driver efficiency >90%, CCT: 3000K - 5700K, minimum CRI>70, etc., with required wiring complete with BIS certification with warranty 5 years warranty. The contractor has to furnish the manufacturer warranty letter, LM 79 and LM 80 certificates. LUMINAIRE MAKE: Phillips / OSRAM / GE Venture / Wipro / Crompton / Bajaj / Havells / Jaquar / Panasonic / Halonix / HPL. LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA / OSRAM / SAMSUNG / LG LEDs. Make & Model will be Approved by the Head Office / Engineer-in-charge.

8

-

75448

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply, transportation and fixing of 18 W +/-10% (>= 1800 Lumens) back lit LED Down Light Recessed / Surface mounting round / square with housing made of Powder coated Pressure die cast aluminium housing with extended heat sink, with Protruded high efficiency diffuser, IP20, with wide operating voltage range, Power factor > 0.9, Surge protection: > 2KV, System efficacy of >100 lumens/watt, CCT: 3000K - 6500K as desired by the department and as per IS, CRI >80, and THD is less than 15% etc., complete with 5 years warranty with BIS Certification. LUMINAIRE MAKE: Phillips / OSRAM / GE Venture / Wipro / Crompton / Bajaj / Havells / Jaquar / Panasonic / Halonix / HPL. LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA / OSRAM / SAMSUNG / LG LEDs. Make & Model will be Approved by the Head Office / Engineer-in-charge.

386

-

780492

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply, transportation and fixing 12 W +/-10% (>= 1200 Lumens) back lit LED Down Light Recessed / Surface mounting round / square with housing made of Powder coated Pressure die cast aluminium housing with extended heat sink, with Protruded high efficiency diffuser, IP20, with wide operating voltage range, Power factor > 0.9, Surge protection: > 2KV, System efficacy of >100 lumens/watt, CCT: 3000K - 6500K as desired by the department and as per IS, CRI >80, and THD is less than 15% etc., complete with 5 years warranty with BIS Certification. LUMINAIRE MAKE: Phillips / OSRAM / GE Venture / Wipro / Crompton / Bajaj / Havells / Jaquar / Panasonic / Halonix / HPL. LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA / OSRAM / SAMSUNG / LG LEDs. Make & Model will be Approved by the Head Office / Engineer-in-charge.

20

-

33280

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply, transportation and fixing 32-36W (>=3240 Lumens) Edge lit, 2' x2' (600mm x 600mm) slim panel Recessed / Surface LED luminaire Square Housing Made of Aluminum alloy with corrosion resistant powder coat, with high efficiency acrylic wide diffuser, with wide operating voltage range, Power factor > 0.9, Surge protection >2KV, System efficacy of >90 lumens/watt, CCT: 3000K - 6500K as desired by the department, CRI >80, and THD is less than 15% with non integrated driver etc., complete with 2 years warranty with BIS Certification. LUMINAIRE MAKE: Phillips / OSRAM / GE Venture / Wipro / Crompton / Bajaj / Havells / Jaquar / Panasonic / Halonix / HPL. LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA / OSRAM / SAMSUNG / LG LEDs. Make & Model will be Approved by the Head Office / Engineer-in-charge.

28

-

103460

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply, transportation and fixing of 22W +/ 10% , >/ 2300 lumens, 1200mm length LED light housing made with alluminium anodised body, wide operating voltage with PF=0.9, Surge protection: > 2KV, THD<10%, with inbuilt driver and frosted cover CCT: 3000K - 6500K as desired by the department as per IS, minimum CRI=80 etc., complete with 5 years warranty with BIS Certification with BIS Certification LUMINAIRE MAKE: Phillips / OSRAM / GE Venture / Wipro / Crompton / Bajaj / Havells / Jaquar / Panasonic / Halonix / HPL. LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA / OSRAM / SAMSUNG / LG LEDs. Make & Model will be Approved by the Head Office / Engineer-in-charge.

732

-

686616

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and run of No. 8SWG GI wire including cost of all accessories and labour charges etc complete.

800

-

19200

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and Run of 25mm x 6mm copper strip (Cuurrent Carrying Capacity 270A) including cost of all accessories and labour charges etc., complete. (1.34 Kg / Mtr)

50

-

76600

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and Run of 25mm x 3mm copper strip (Cuurrent Carrying Capacity 270A) including cost of all accessories and labour charges etc., complete.

140

-

107240

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;upply and Run of 50mm x 6mm G.I Strip including cost of all accessories and labour charges etc., complete.

215

-

59985

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and Run of 25mm x 6mm G.I Strip including cost of all accessories and labour charges etc., complete.

330

-

45540

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Providing independent earthing for Important equipment with 100mm dia Heavy gauge C.I ( Cast iron ) pipe with Flange 2.5m long enclosed in C.C/ brick massonry chamber of 450m x 450m x 400mm with R.C.C. Slab cover duly providing staggered holes filling with salt and charcoal from the bottom of the pipe giving earth connection from electrode through flange with all accessories and labour charges complete, as per IS specifications 732/1982 (Part II)

9

-

97650

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Providing independent earthing by exacavating a pit to a depth of 2.25Mtr in all soils as per size specified in the data for Sophisticated Electronic equipment with 600mm x 600mm x 3.15mm thick copper plate rigidly fixed to 19mm dia 'B' Class G.I Pipe of 2.5Mtr lengthwith funnel as per National Electric Code and earth connection from electrode GI strip of 40mm x 5mm x 200mm length to be bolted with nut bolts to G.I.pipe including 25mm x 3mm copper strip of 6Mtrs length connected from plate to GI strip including filling with 20Kg Salt and 40Kg Charcoal or 40Kg bentonite powder from the bottom of the pipe and providing CC / Brick massonry chamber 450mmX450mmX400mm and covered with R.C.C. Slab including all accessories and labour charges etc complete as per IS specification 732/1982 (Part II).

11

-

208340

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Providing independent earthing for Important equipment with 40mm dia 'B' class 2.5m long G.I pipe and 19mm dia 'B' class G.I pipe of 0.3mtr. long connected with reducer providing G.I funnel with mesh enclosed in C.C/ brick massonry chamber of 450m x 450m x 400mm withR.C.C. Slab cover duly providing staggered holes filling with 20Kg Salt and 40Kg Charcoal or 40Kg bentonite powder from the bottom of the pipe giving earth connection from electrode through G.I strip of 40 x 6mm x 200mm length with all accessories and labour charges complete, as per IS specifications 732/1982 (Part II)

25

-

165750

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and Installation of 250 Amps 4 Pole MCCB, Adjustable, Confirms to IS/IEC 60947-2 having Breaking Capacity 36 KA with thermal magnetic release with suitable SS Enclosure and angle iron frame work on wall / floor including all Labours charges massonry work etc complete with connections. Makes : L&T- D sine / Schneider-NS NSX/Legrand -DP X3/ Siemens-3VL / Hager-h3/C&S -Winbreak.

1

-

48743

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and Installation of 125 Amps 4 Pole MCCB, Adjustable, Confirms to IS/IEC 60947-2 having Breaking Capacity 25 KA with thermal magnetic release with suitable SS Enclosure and angle iron frame work on wall / floor including all Labours charges massonry work etc complete with connections. Makes : L&T- D sine / Schneider-NS NSX/Legrand -DP X3/ Siemens-3VL / Hager-h3/C&S -Winbreak.

2

-

49100

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and Installation of 63A 4 Pole MCCB, Adjustable, Confirms to IS/IEC 60947-2 having Breaking Capacity 16 KA with thermal magnetic release with suitable SS Enclosure and angle iron frame work on wall / floor including all Labours charges massonry work etc complete with connections. Makes : L&T- D sine / Schneider-NS NSX/Legrand -DP X3/ Siemens-3VL / Hager-h3/C&S -Winbreak.

6

-

103770

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and fixing of cable adopteres box with cover for DBs including, massanory work etc., complete., Makes : Legrand / Schneider / Siemens / L&T / Hager / Cabtree Xpro

64

-

38400

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and fixing of 8 Way VTPN DB with IP 43 Protection as per IS:13032 with 1 No., of 125A 4P MCCB, Adjustable, Confirms to IS/IEC 60947-2 having Breaking Capacity 25 KA with thermal magnetic release Panel Mounted as incomer with 8 Nos of 63A TP MCBs 10KA, C/D Curve ISI Mark as Out goings including internal connections and labour charges for FLUSH Mounting etc., complete. DB Makes : Legrand / Schneider / Siemens / L&T / Cabtree Xpro. MCB Makes : Legrand-DX3 / Schneider-Acti9 / Siemens / L&T Exora / Cabtree. MCCB Makes : Makes : L&T- D sine / Schneider-NS NSX/Legrand -DP X3/ Siemens-3V / Hager-h3 / C&S -Winbreak.

6

-

326742

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and fixing of 4 Way TPN DB Horizontal with IP 43 Protection as per IS:13032 with 1 No., of 63A FP MCB 10KA, C/D Curve ISI Mark as incomer and 12 Nos 6-32 A 10 KA SP MCBs 10KA, C/D Curve ISI Mark as out goings including internal connections and labour charges for FLUSH Mounting etc., complete. (For Power DBs) DB Makes : Legrand / Schneider / Siemens / L&T / Cabtree Xpro. MCB Makes : Legrand-DX3 / Schneider-Acti9 / Siemens / L&T Exora / Cabtree.

33

-

454839

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and fixing of 4 Way TPN DB Horizontal with IP 43 Protection as per IS:13032 with 1 No., of 32A FP MCB 10KA, C/D Curve ISI Mark as incomer and 12 Nos 6-32 A 10KA SP MCBs 10KA, C/D Curve ISI Mark as out goings including internal connections and labour charges for FLUSH Mounting etc., complete. (For Lighting DBs) DB Makes : Legrand / Schneider / Siemens / L&T / Cabtree Xpro. MCB Makes : Legrand-DX3 / Schneider-Acti9 / Siemens / L&T Exora / Cabtree.

26

-

332800

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and fixing of 8 Way SPN DB with IP 43 Protection as per IS:13032 with 1 No 40A DP MCB as Incommer, and 6 Nos of 20A SP MCB 10KA, C/D Curve ISI Mark as out goings, concealing in wall etc complete. DB Makes : Legrand / Schneider / Siemens / L&T / Cabtree Xpro. MCB Makes : Legrand-DX3 / Schneider-Acti9 / Siemens / L&T Exora / Cabtree.

9

-

68229

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and fixing of DP/FP Metal Enclosure with IP 20 Protection DB Make with 1 No 20A, 10 KA DP MCB including internal connection and labour charges for Flush Mounting etc.,complete. Makes of Enclousure : Legrand / Schneider / Siemens / L&T / Crabtree Xpro / ABB / C&S MCB Makes : Legrand-DX3 / Schneider-Acti9 / Siemens / L&T Exora / Cabtree.

78

-

169806

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and Run of 5 of 10.0 Sq.mm FRLSH / HFFR PVC insulated 1100V grade as per IS:694/1990, IS 17048 specifications for Copper cable in the existing conduict pipe for run of mains from VTPN / Panel Board to TPN DB"s with pin type lugs and connections etc., complete. [for PDBs] Makes of wires : Finolex / RR kabel / Havells / Polycab / Finecab Gold (HFFR) / GM(HFFR) / Gold Medal(HFFR) / Million (HFFR) / KEI (HFFR) / V-Guard (HFFR) / DEC (HFFR).

950

-

780900

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and Run of 5 of 6.0 Sq.mm FRLSH / HFFR PVC insulated 1100V grade as per IS:694/1990, IS 17048 specifications for Copper cable in the existing conduict pipe for run of mains from VTPN / Panel Board to TPN DB"s with pin type lugs and connections etc., complete. [for LDBs] Makes of wires : Finolex / RR kabel / Havells / Polycab / Finecab Gold (HFFR) / GM(HFFR) / Gold Medal(HFFR) / Million (HFFR) / KEI (HFFR) / V-Guard (HFFR) /DEC (HFFR).

950

-

489250

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and Run of 3 of 6.0 sq mm (phase neutral and earth) FRLSH / HFFR PVC insulated 1100V grade as per IS:694/1990, IS 17048 specifications for Copper cable of in existing pipe for SPNDB's incoming inlcuding all labour charges etc., complete. Makes of wires : Finolex / RR kabel / Havells / Polycab / Finecab Gold (HFFR) / GM(HFFR) / Gold Medal(HFFR) / Million (HFFR) / KEI (HFFR) / V-Guard (HFFR) / DEC (HFFR).

1975

-

600400

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and Run of 3 of 4.0 sq mm (phase neutral and earth) FRLSH / HFFR PVC insulated 1100V grade as per IS:694/1990, IS 17048 specifications for Copper cable of in existing pipe for power points and AC Sockets inlcuding all labour charges etc., complete. Makes of wires : Finolex / RR kabel / Havells / Polycab / Finecab Gold (HFFR) / GM(HFFR) / Gold Medal(HFFR) / Million (HFFR) / KEI (HFFR) / V-Guard (HFFR)/ DEC (HFFR).

6300

-

1360800

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and Run of 3 of 2.5 sq.mm (phase, neutral and earth) FRLSH / HFFR PVC insulated 1100V grade as per IS:694/1990, IS 17048 specifications for Copper cable of in existing pipe. Makes of wires : Finolex / RR kabel / Havells / Polycab / Finecab Gold (HFFR) / GM(HFFR) / Gold Medal(HFFR) / Million (HFFR) / KEI (HFFR) / V-Guard (HFFR) / DEC (HFFR).

6500

-

975000

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and Run of 1 of 1.5 sq.mm (Earth) FRLSH / HFFR PVC insulated 1100V grade as per IS:694/1990, IS 17048 specification for Copper cable. specifications for Copper cable in the existing conduict pipe for earth continuity inlcuding all labour charges etc., complete. Makes of wires : Finolex / RR kabel / Havells / Polycab / Finecab Gold (HFFR) / GM(HFFR) / Gold Medal(HFFR) / Million (HFFR) / KEI (HFFR) / V-Guard (HFFR)/ DEC (HFFR).

3710

-

126140

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and fixing of following switches and sockets modular type on suitable size Modular deep box with cover frame including cost and coveyance of all material and all labour charges etc., complete with following configurations. 1) 16A / 6A 2 Module Combi Socket Modular Socket with shutter - 1 No 2) 16A/20A 1 Way 1 Module Modular Switch. - 1 No 3) 10A 3/2 Pin 2 Module Modular Socket with shutter - 3 Nos. 4) 6 / 10A 1 Way 1 Module Modular Switch - 3 Nos. including cost and coveyance of all material and all labour charges etc., complete for LAB,ICU's and OTs Use Makes of switches : Legrand Arteor / Schneider Zen celo / Honeywell Blenge Plus / Cabtree Amare / Logus Platina / Gold Medal GIFA / GM-Zenova/ L&T- Englaze.

83

-

204595

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and fixing of following switches and sockets modular type on suitable size Modular deep box with cover frame including cost and coveyance of all material and all labour charges etc., complete with following configurations 1) 16A / 6A 2 Module Combi Socket Modular Socket with shutter - 1 No 2) 16A/20A 1 Way 1 Module Modular Switch. - 1 No 3) 10A 3/2 Pin 2 Module Modular Socket with shutter - 1 Nos. 4) 6 / 10A 1 Way 1 Module Modular Switch ? 1 Nos. including cost and coveyance of all material and all labour charges etc., complete for Computer, LAB and OTs Use Makes of switches : Legrand Arteor / Schneider Zen celo / Honeywell Blenge Plus / Cabtree Amare / Logus Platina / Gold Medal GIFA / GM-Zenova/ L&T- Englaze.

80

-

111600

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and fixing of 16A / 6A 2 Module Combi Socket Modular Socket with shutter with 16A/20A 1 Way 1 Module Modular Switch fixed on suitable size Modular box with required cover frame including with connections, cost and conveyance of all material and all labour charges etc., complete Makes of switches : Legrand Arteor / Schneider Zen celo / Honeywell Blenge Plus / Cabtree Amare / Logus Platina / Gold Medal GIFA / GM-Zenova/ L&T- Englaze.

93

-

82212

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and fixing of 6 / 10A 1 Way 1 Module Modular Switches - 4 Nos and 10A 3/2 Pin 2 Module Modular Socket with shutter - 4 Nos Modular type with cover plate and GI switch box fixing on separate board including all labour charges etc., complete. Makes of switches : Legrand Arteor / Schneider Zen celo / Honeywell Blenge Plus / Cabtree Amare / Logus Platina / Gold Medal GIFA / GM-Zenova/ L&T- Englaze.

98

-

215894

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and fixing of 6 / 10A 1 Way 1 Module Modular Switch - 2 Nos and 10A 3/2 Pin 2 Module Modular Socket with shutter - 3 Nos Modular type with cover plate and GI switch box fixing on separate board including all labour charges with connections etc., complete. Makes of switches : Legrand Arteor / Schneider Zen celo / Honeywell Blenge Plus / Cabtree Amare / Logus Platina / Gold Medal GIFA / GM-Zenova/ L&T- Englaze.

76

-

123804

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and fixing of 6 / 10A 1 Way 1 Module Modular Switches - 2 Nos and 10A 3/2 Pin 2 Module Modular Socket with shutter - 2 Nos Modular type with cover plate and GI switch box fixing on separate board including all labour charges etc., complete. Makes of switches : Legrand Arteor / Schneider Zen celo / Honeywell Blenge Plus / Cabtree Amare / Logus Platina / Gold Medal GIFA / GM-Zenova/ L&T- Englaze.

58

-

73892

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and fixing of 10A 3/2 Pin 2 Module Modular Socket with shutter with 6 / 10A 1 Way 1 Module Modular Switch, 3 Module box with cover frame in Common switch board including cost and conveyance of all materials and all labour charges etc., complete in N.R.B. / R.B. Makes of switches : Legrand Arteor / Schneider Zen celo / Honeywell Blenge Plus / Cabtree Amare / Logus Platina / Gold Medal GIFA / GM-Zenova/ L&T- Englaze.

290

-

188790

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Wiring with run of 2 of 1.5 Sqmm FRLSH / HFFR PVC insulated 1100V grade as per IS:694/1990, IS 17048 specification for Copper cable. in existing PVC conduit pipe including Supply and fixing of Jumbo Ceiling rose and 6A/10A ISI Mark 1way Modular switch with required modular box and cover frame in existing Surface or Concealed pipe wiring including cost and conveyance of all material and all labour charges etc., complete for staircase light points in N.R.B. Makes of wires : Finolex / RR kabel / Havells / Polycab / Finecab Gold (HFFR) / GM(HFFR) / Gold Medal(HFFR) / Million (HFFR) / KEI (HFFR) / V-Guard (HFFR)./ DEC (HFFR). Makes of switches : Legrand Arteor / Schneider Zen celo / Honeywell Blenge Plus / Cabtree Amare / Logus Platina / Gold Medal GIFA / GM-Zenova/ L&T- Englaze.

16

-

21824

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Wiring with run of 2 of 1.5 Sqmm FRLSH / HFFR PVC insulated 1100V grade as per IS:694/1990, IS 17048 specification for Copper cable. in existing PVC conduit pipe including Supply and fixing of Jumbo Ceiling rose and 6A/10A ISI Mark 1way Modular switch with required modular box and cover frame in existing Surface or Concealed pipe wiring including cost and conveyance of all material and all labour charges etc., complete for light, Fan, Exhaust fan and bell points in N.R.B. Makes of wires : Finolex / RR kabel / Havells / Polycab / Finecab Gold (HFFR) / GM(HFFR) / Gold Medal(HFFR) / Million (HFFR) / KEI (HFFR) / V-Guard (HFFR)./ DEC (HFFR). Makes of switches : Legrand Arteor / Schneider Zen celo / Honeywell Blenge Plus / Cabtree Amare / Logus Platina / Gold Medal GIFA / GM-Zenova/ L&T- Englaze.

1848

-

1679832

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and erecting PVC / GI / MS Galvanished fan hook box with hook in RCC slab including all Labour charges etc., complete.

286

-

42614

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and Fixing of ISI 25mm outer dia medium grade, with IS:9537 part 3 rigid PVC with all accessories fixing on chromium plated metallic base saddles including all labour charges etc., complete for run of mains. Makes:- Sudhakar / Finolex / Modi / VIP / Precision / Universal / Million Plast / Gold / Polycab / DEC.

10500

-

955500

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and laying of ISI 25mm outer dia medium grade, with IS:9537 part 3 rigid PVC concealed in wall with all required PVC / Metallic Junction Boxes including masonary work and labour charges etc., Makes:- Sudhakar / Finolex / Modi / VIP / Precision / Universal / Million Plast / Gold / Polycab / DEC.

15880

-

1556240

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and Laying of ISI 25mm outer dia heavy grade with IS:9537 part 3 rigid PVC pipe concealed in Roof Slabs with all required PVC / Metallic Deep Boxes including masonary work and labour charges etc., complete. Makes : Sudhakar / Finolex / Modi / VIP / Precision / Universal / Million Plast / Gold / Polycab / DEC

13395

-

1245735

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supplying,laying,jointing of Single Socket Solfit Pipe SN 8 (6Mtr) (for Underground) pipe of Ashirvad make of Conforming to ISI including excavation of trenches and socket pits in any soil (except rock requiring blasting) and refilling with watering and tamping to the required slope including cost and conveyance of all materials to site and all labour charges, overheads & contractor profit etc., complete for finished item of work. 315mm dia

60

-

235980

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supplying,laying,jointing of Single Socket Solfit Pipe SN 8 (6Mtr) (for Underground) pipe of Ashirvad make of Conforming to ISI including excavation of trenches and socket pits in any soil (except rock requiring blasting) and refilling with watering and tamping to the required slope including cost and conveyance of all materials to site and all labour charges, overheads & contractor profit etc., complete for finished item of work. 160mm dia

20

-

22360

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supplying,laying,jointing of Single Socket Solfit Pipe SN 8 (6Mtr) (for Underground) pipe of Ashirvad make of Conforming to ISI including excavation of trenches and socket pits in any soil (except rock requiring blasting) and refilling with watering and tamping to the required slope including cost and conveyance of all materials to site and all labour charges, overheads & contractor profit etc., complete for finished item of work. 110mm dia

20

-

11160

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply & Fixing of G.I U Type clamps to support SWR & CPVC pipes, including cost and conveyance of all materials to site, labour charges, complete for finished item of work at all floor levels. For 150 mm dia pipes

170

-

32640

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply & Fixing of G.I U Type clamps to support SWR & CPVC pipes, including cost and conveyance of all materials to site, labour charges, complete for finished item of work at all floor levels. For 100 mm dia pipes

364

-

61880

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply & Fixing of G.I U Type clamps to support SWR & CPVC pipes, including cost and conveyance of all materials to site, labour charges, complete for finished item of work at all floor levels. For 25 to 75mm dia pipes

162

-

22680

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Providing and placing on terrace (at all floor levels)polyetheylene water storage tank with double layer approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet and outlets and over flow pipes but without fittings and base support for tanks including cost and conveyance of all materials and labour charges , overheads & contractors profit complete for finished item of work.

2500

-

25575

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supplying & Fixing Indian make white glazed vitreous china porcelain sink conforming to IS:2556-Part-5-1994 on cantilever brackets with waste fittings like rubber plug, chain,32 mm nominal size C.P. Fitting with parallel pipe thread conforming to IS:2963-1979 : 750 x 450 x 250of Ist quality ncluding chiselling brick masonry wall and making good & restoring to original surfaces overheads & contractors profit complete.for finished item of work in all floors..

10

-

53220

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supplying and fixing of stainless steel sink of size 508.00mm x 457.2mm x 203.20mm, 1mm thick of Indian make fixed on cantilever brackets including supply and fixing 31.75mm C.P. waste coupling, 30mm dia PVC flexible waste pipe of 914.4 mm length of Ist quality ncluding chiselling brick masonry wall and making good & restoring to original surfaces, overheads & contractors profit complete for finished item of work in all floors.

42

-

232428

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Construction of brick masonry support for GI pipe of size 304.80mm x 228.60mm x 228.60 mm in CM (1:8) prop including plastering and finishing with 12mm thick in CM (1:5) including cost and conveyance of all materials and all labour charges, overheads & contractors profit complete for finished item of work for all floors.

235

-

23970

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supplying and fixing of SWR PVC pipes (Prince/ Sudhakar/ Kisan/ Supreme or any ISI brand) 4 Kg/Sq.cm. and fixing all special such as plain bends, off sets, door bends, single junctions, double junctions as per site requirement, fixing with PVC clamps if necessary with required number of Bombay nails including cost and conveyance of all materials to site, labour charges, overheads & contractors profit complete for finished item of work at all floor levels. (APSS No. 1302 1319 & 1326) 160mm dia

512

-

334336

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supplying and fixing of SWR PVC pipes (Prince/ Sudhakar/ Kisan/ Supreme or any ISI brand) 4 Kg/Sq.cm. and fixing all special such as plain bends, off sets, door bends, single junctions, double junctions as per site requirement, fixing with PVC clamps if necessary with required number of Bombay nails including cost and conveyance of all materials to site, labour charges, overheads & contractors profit complete for finished item of work at all floor levels. (APSS No. 1302 1319 & 1326) 110mm dia

1120

-

397600

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supplying and fixing of SWR PVC pipes (Prince/ Sudhakar/ Kisan/ Supreme or any ISI brand) 4 Kg/Sq.cm. and fixing all special such as plain bends, off sets, door bends, single junctions, double junctions as per site requirement, fixing with PVC clamps if necessary with required number of Bombay nails including cost and conveyance of all materials to site, labour charges, overheads & contractors profit complete for finished item of work at all floor levels. (APSS No. 1302 1319 & 1326) 75mm dia

1381

-

352155

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supplying and fixing Bronze Gate/ Globe valve as per IS - 778 Class - I, Indian make heavy type including cost and conveyance of all materials , labour charges , overheads & contractors profit complete for finished item of work. 65mm Nominal bore

6

-

41310

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supplying and fixing Bronze Gate/ Globe valve as per IS - 778 Class - I, Indian make heavy type including cost and conveyance of all materials , labour charges , overheads & contractors profit complete for finished item of work. 50mm Nominal bore

12

-

53532

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supplying and fixing Bronze Gate/ Globe valve as per IS - 778 Class - I, Indian make heavy type including cost and conveyance of all materials , labour charges , overheads & contractors profit complete for finished item of work. 32mm Nominal bore

28

-

63140

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supplying and fixing Bronze Gate/ Globe valve as per IS - 778 Class - I, Indian make heavy type including cost and conveyance of all materials , labour charges , overheads & contractors profit complete for finished item of work. 25mm Nominal bore

43

-

63812

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supplying and fixing Bronze Gate/ Globe valve as per IS - 778 Class - I, Indian make heavy type including cost and conveyance of all materials , labour charges , overheads & contractors profit complete for finished item of work. 20mm Nominal bore

425

-

439025

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supplying and fixing 65 mm Nominal Bore GI pipe Medium Grade properties & weight as per IS 1239 in ground or on wall with GI fittings such as elbows tees couplings, nipples, plugs including excavation for trenches and refilling the trenches ,chiselling masonry walls and making good the walls & floors to the original surface and fixing MS clamps on TW blocks on walls including cost and conveyance of all materials and labour charges , overheads & contractors profit complete for finished item of work except for GI bends union and GI connectors with checkout and socket Tata or Zenith make or equivalent.

180

-

191340

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and fixing of Ashirvad/ Ajay/ Astral Flowguard or equivalent CPVC Pipes and Fittings SDR 11 to meet the requirement of ASTM-D 2846 and are produced in CTS (Copper Tube Sizes 1/2" to 2") for hot and cold water (IS 15778:2007) including cost and conveyance of all materials to site, labour charges for fixing, overheads & contractors profit complete for finished item of work at all floor levels. 54.00mm OD pipe

20

-

13480

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and fixing of Ashirvad/ Ajay/ Astral Flowguard or equivalent CPVC Pipes and Fittings SDR 11 to meet the requirement of ASTM-D 2846 and are produced in CTS (Copper Tube Sizes 1/2" to 2") for hot and cold water (IS 15778:2007) including cost and conveyance of all materials to site, labour charges for fixing, overheads & contractors profit complete for finished item of work at all floor levels. 41.30mm OD pipe

300

-

138600

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and fixing of Ashirvad/ Ajay/ Astral Flowguard or equivalent CPVC Pipes and Fittings SDR 11 to meet the requirement of ASTM-D 2846 and are produced in CTS (Copper Tube Sizes 1/2" to 2") for hot and cold water (IS 15778:2007) including cost and conveyance of all materials to site, labour charges for fixing, overheads & contractors profit complete for finished item of work at all floor levels. 34.90mm OD pipe

52

-

19396

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and fixing of Ashirvad/ Ajay/ Astral Flowguard or equivalent CPVC Pipes and Fittings SDR 11 to meet the requirement of ASTM-D 2846 and are produced in CTS (Copper Tube Sizes 1/2" to 2") for hot and cold water (IS 15778:2007) including cost and conveyance of all materials to site, labour charges for fixing, overheads & contractors profit complete for finished item of work at all floor levels. 28.60mm OD pipe

237

-

64938

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and fixing of Ashirvad/ Ajay/ Astral Flowguard or equivalent CPVC Pipes and Fittings SDR 11 to meet the requirement of ASTM-D 2846 and are produced in CTS (Copper Tube Sizes 1/2" to 2") for hot and cold water (IS 15778:2007) including cost and conveyance of all materials to site, labour charges for fixing, overheads & contractors profit complete for finished item of work at all floor levels. 22.20mm OD pipe

310

-

70680

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and fixing of Ashirvad/ Ajay/ Astral Flowguard or equivalent CPVC Pipes and Fittings SDR 11 to meet the requirement of ASTM-D 2846 and are produced in CTS (Copper Tube Sizes 1/2" to 2") for hot and cold water (IS 15778:2007) including cost and conveyance of all materials to site, labour charges for fixing, overheads & contractors profit complete for finished item of work at all floor levels. 15.90mm OD pipe

795

-

150255

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supplying and fixing of 101.60mm x 609.60mm white glazed porcelain channels 1st quality fixed in brick masonry to the required slopes, white cement pointing including cost and conveyance of all materials and labour charges, overheads & contractors profit complete for finished item of work for all floors..

44

-

42988

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supplying and fixing of 16mm to 20 mm thick polished marble slab partitioins of size 4' 0" x 2' 0" for urinals including full rounding the edges, fixing in position, polishing, including cost and conveyance of all materials and labour charges, overheads & contractors profit complete for finished item of work for all floors.

36

-

93312

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supplying and fixing white glazed flat back half stall urinals of size 590 mm x 375 mm x 390 mm with integral flushing rim fixed with screws complete Indian make (HSW/Parry/Neycer) conforming to IS:2556-1995 as approved by Engineer-in-charge, including supply and fixing 12.7mm PVC connection with brass plumber union nuts CP coated, 12.70mm push cock 1st quality of approved make, 30mm dia PVC flexible waste pipe of 914.4 mm length of Ist quality including cost and conveyance of all materials to site, labour charges etc., overheads & contractors profit complete for finished item of work for all floors.

72

-

350784

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supplying and fixing Chromium plated finish brass body quarter turn Bibcock cum Health Faucet with 1m long tube and wall hook with 7 - 10 years warranty with necessary fittings etc., complete including cost and conveyance of all materials, labour charges, overheads & contractor profit complete for finished item of work in all floors.

150

-

581550

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supplying and fixing 15 mm brass body CP finish self closing tap push type conforming to IS 1711 as approved by the Engineer-In-Charge including cost and conveyance of all materials, labour charges, overheads & contractors profit complete for finished item of work in all floors.

28

-

9548

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supplying and fixing 15 mm brass body CP finish bib tap of not less than 300 grams weight screw type (full turn) with internal / external threaded connection conforming to IS 8931 as approved by the Engineer-In-Charge including cost and conveyance of all materials, labour charges , overheads & contractors profit complete for finished item of work in all floors.

175

-

54425

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supplying and fixing of 25.4mm dia, 609.6mm long aluminium anodized towel rods with brackets and aluminium screws including cost and conveyance of all materials, labour charges , overheads & contractors profit for finished item of work.

120

-

23880

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supplying and fixing TV shape mirror with plastic frame of size 609.6mm x 457.2mm , plywood back with NP screws 1st quality including cost and conveyance of all materials, labour charges , overheads & contractors profit for finished item of work in all floors.

121

-

74778

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supplying and fixing CP finish brass soap dish of approved make ISI quality including cost and conveyance of all materials, labour charges for fixing, overheads & contractors profit for finished item of work in all floors

121

-

86152

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supplying and fixing Indian make Flat Back Wash Hand Basin 1st quality conforming to IS:2556-Part-4:1972 of size 550mm x 400mm with 32 mm nominal size C.P. Fitting with parallel pipe thread conforming to IS:2963-1979 and fitted with 15 mm nominal bore Chromium Plated Pillar Tap of 1st quality Indian make heavy duty complete with standard CI brackets including wooden blocks ,1 No.12.70mm PVC connection with brass union nuts CP coated , angle stop cock 12.70mm dia. first quality Indian make heavy duty, 30mm dia. PVC flexible waste pipe 914.4mm length of 1st quality including cost and conveyance of all materials to site, labour charges , overheads & contractors profit for finished item of work.

206

-

634274

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supplying and fixing 580mm x 440mm long Orissa pan white glazed Water Closet 1st quality ISI marked confirming to IS:2556-Part-3-1981 with "P" or "S" trap, ISI marked and providing masonry seat, CC squatting plate and 10 litres capacity single flush PVC low level cistern with internal components fixed on 2 Nos. of teak wood blocks of size 76.20mm x 101.60mm using required size of nails, screws as approved by Engineer-in-charge, 15 mm nominal size CP finish brass angled stop valve screw type with internal /external threaded conforming to IS 8931, 12.70mm PVC connection with brass union nuts CP coated , 31.75mm brass plumber union, P trap or S trap of Indian W.C. shall be encased on CC (1:2:4) 150mm alround well above the joint to stop leakage at the joint etc., complete including cost and conveyance of all materials to site, cost of CC bed, labour charges and seigniorage charges, overheads & contractors profit etc., complete for finished item of work.

32

-

178304

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supplying and fixing European Water Closet of 1st quality conforming to IS:2556-Part-2-1973 of white glazed with 'S' trap,supplying and fixing best Indian make plastic seat and lid for European water closets with rubber or plastic Buffers as per IS 2548-1996 and 10 litres capacity single flush PVC low level cistern with internal components and fixed using required size of nails and screws, 15 mm nominal size CP finish brass angled stop valve screw type with internal /external threaded conforming to IS 8931, 12mm PVC connections with brass union nuts CP coated including cost and conveyance of all materials to site, overheads & contractors profit etc., complete for finished item of work for all floors.

155

-

976655

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supplying and fixing of 4" (101.6mm) multi floor trap with jali - UPVC/SWR pipe fittings as per site requirements with standard practice for all floors including cost and conveyance of all materials to site, labour charges , overheads & contractors profit etc., complete for finished item of work.

292

-

54604

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Constructing 904.0 mm (3?0?) dia brick masonry inspection chamber as per IS - 4111: Part-1:1986 with cement mortar (1:6) prop using 2nd Class Clay Bricks of 225 mm thick from approved source having a minimum crushing strength of 5 N/sq.mm including plastering with cement mortar 1:3 prop; ½? thick both inside and outside fitted with 20? dia RCC manhole covers and frames including excavating pits up to a depth of 1524 mm (5'-0") in all sorts of soils (exculding rock) and laying cement conrete (1:4:8) 150 mm thick using 40 mm HBG Metal and P.C.C. 1:2:4 benching and channel 100 mm thick as per Standard specification and including cost and conveyance of all materials like cement, sand, bricks, water etc., to site, cost of seigniorage charges on all materials and all incidental and operational, labour charges like mixing cement mortar, constructing masonry, lift charges, curing , overheads & contractors profit etc., complete for finished item of work as per Standard specification.

15

-

237210

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Constructing 904.0 mm (3?0?) dia brick masonry inspection chamber as per IS - 4111: Part-1:1986 with cement mortar (1:6) prop using 2nd Class Clay Bricks of 225 mm thick from approved source having a minimum crushing strength of 5 N/sq.mm including plastering with cement mortar 1:3 prop; ½? thick both inside and outside fitted with 20? dia RCC manhole covers and frames including excavating pits up to a depth of 904 mm (3'-0") in all sorts of soils (exculding rock) and laying cement conrete (1:4:8) 150 mm thick using 40 mm HBG Metal and P.C.C. 1:2:4 benching and channel 100 mm thick as per Standard specification and including cost and conveyance of all materials like cement, sand, bricks, water etc., to site, cost of seigniorage charges on all materials and all incidental and operational, labour charges like mixing cement mortar, constructing masonry, lift charges, curing , overheads & contractors profit etc., complete for finished item of work as per Standard specification.

41

-

400939

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supplying and fixing of SWG Gully traps 150mm x 100mm of ISI make confirming to IS 651 & 4127 with C.I grating & constructing cement brick masonry in CM (1:6) prop., intermediate chamber and fitted with 304.8 mm X 288.6 mm (12"x9") C.I Frame with hinged cover of standard make as approved including cost and conveyance of all materials to site, labour charges, overheads & contractors profit etc., complete for finished item of work.

88

-

67584

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Constructing 457.2 mm x 457.2 mm (1'6"x1'6") brick in CM 1:6 prop. Masonry. Inspection chamber upto 914.4 mm (3'0") and fitted with light weight 457.2 mm x 457.2 mm (1'6"x1'6") C.I frame and cover of 20 Kg including cost and conveyance of all materials like cement, sand, bricks, water etc., to site, cost of seigniorage charges on all materials and all incidental and operational, labour charges like mixing cement mortar, constructing masonry, lift charges, curing , overheads & contractors profit etc., complete for finished item of work as per Standard specification.

109

-

550886

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supplying and laying, filling, jointing and testing SWG SP-1 pipe conforming to ISI 651 & 4127 with air tight Cement joints in CM (1.5:1) prop. including excavation of trenches and socket pits in any soil (except rock requiring blasting) and refilling with watering and tamping to the required slope including cost and conveyance of all materials to site and all labour charges , overheads & contractor profit etc., complete for finished item of work (APSS NO 1301 & 1318).300mm dia upto 1524mm (5') depth

25

-

57075

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supplying and laying, filling, jointing and testing SWG SP-1 pipe conforming to ISI 651 & 4127 with air tight Cement joints in CM (1.5:1) prop. including excavation of trenches and socket pits in any soil (except rock requiring blasting) and refilling with watering and tamping to the required slope including cost and conveyance of all materials to site and all labour charges , overheads & contractor profit etc., complete for finished item of work (APSS NO 1301 & 1318).203.20mm dia upto 1524mm (5') depth

220

-

265980

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supplying and laying, filling, jointing and testing SWG SP-1 pipe conforming to ISI 651 & 4127 with air tight Cement joints in CM (1.5:1) prop. including excavation of trenches and socket pits in any soil (except rock requiring blasting) and refilling with watering and tamping to the required slope including cost and conveyance of all materials to site and all labour charges , overheads & contractor profit etc., complete for finished item of work (APSS NO 1301 & 1318). 152.40mm dia upto 1524.0mm (5') depth

250

-

235250

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supplying and laying, filling, jointing and testing SWG SP-1 pipe conforming to ISI 651 & 4127 with air tight Cement joints in CM (1.5:1) prop. including excavation of trenches and socket pits in any soil (except rock requiring blasting) and refilling with watering and tamping to the required slope including cost and conveyance of all materials to site and all labour charges , overheads & contractor profit etc., complete for finished item of work (APSS NO 1301 & 1318). 101.60mm dia upto 914.40mm (3') depth

10

-

5620

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Painting two coats with synthetic enamel paint Grade-II VOC (Volatile Organic Compound) content less than 50 grams/litre to new iron work including cost and conveyance of all materials to site, sales & other taxes, incidental, operational and all labour charges etc., and overheads & contractors profit complete for finished item of work in all floors. (SS No. 1201, 1212 & 1207).

105

-

12075

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Construction of un-reinforced, dowel jointed at expansion and construction joint only, plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS : 383, maximum in a concrete mixer of not less than 0.2 cum capacity and appropeiate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 mictron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with sholvels, rakes, compacted using needle, scareed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer, sealant, dowel bars, near approaches to bridge / culvert and construction joints, admixtures as approved, curing of concrete slabs for 14- days, curing compound (where specified) and water finishing to lines and grade as per drawing and Technical Specification Clause 1501 MORD.

518

-

4036256

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Plain Cement Concrete M 20 design mix using Concrete Batching Plant, 20mm size hard granite machine crushed graded metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry, using a minimum quantity of 330 kgs. of cement per 1 cum of concrete including cost and conveyance of all materials like cement, fine aggregate (Sand), coarse aggregate, water etc., to site including steel centering, shuttering, machine mixing, lift charges, laying concrete,vibrating, curing, overheads & contrctors profit etc., complete for finished item of work (APSS No. 402 & 403) for Saucer drain

9

-

70119

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Plain Cement Concrete (1:3:6) nominal mix using 40mm size machine crushed hard granite metal (coarse aggregate) in (2:1) ratio from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand), coarse aggregate, water etc. to site, sales & other taxes on all materials, all charges for mixing, laying concrete in position, curing charges, overheads & contractors profit etc., for finished item of work for Central Median

19

-

106438

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Plain Cement Concrete M 20 design mix using WEIGH BATCHER / MIXER, 20mm size hard granite machine crushed graded metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry, using a minimum quantity of 350 kgs. of cement per 1 cum of concrete including cost and conveyance of all materials like cement, fine aggregate (Sand), coarse aggregate, water etc., to site including steel centering, shuttering, machine mixing, lift charges, laying concrete,vibrating, curing, overheads & contrctors profit etc., complete for finished item of work (APSS No. 402 & 403) for Kerb stone.

26

-

178906

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Construction of Granular sub-base by providing HBG material confirming to Grading - III of MORT & H Table 400-2 including cost, seigniorage charges and conveyance of all material to woek site and spreading in uniform layers with motor grader or by approved means, on prepared surface mixing by mix place method with Rotavator/ approved means, at OMC and compacting with vibratory roller to achieve the desired density etc., complete for finished item of work as per MoRT& H specification 401 (4th revision) and as directed by the Engineer- in - charge (Payment will be made based on levels for finished item of work)

153

-

137547

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Providing Access Scaffolding using Casuarinas Ballies, Bamboos, Supporting Wooden Brackets including hire charges and labour charges for external ducts, including cost and conveyance of all materials including overheads & Contractor profit etc., for finished item of work. Third Floor :

720

-

18000

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Providing Access Scaffolding using Casuarinas Ballies, Bamboos, Supporting Wooden Brackets including hire charges and labour charges for external ducts, including cost and conveyance of all materials including overheads & Contractor profit etc., for finished item of work. Second Floor :

720

-

14400

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Providing Access Scaffolding using Casuarinas Ballies, Bamboos, Supporting Wooden Brackets including hire charges and labour charges for external ducts, including cost and conveyance of all materials including overheads & Contractor profit etc., for finished item of work. Ground Floor/ First Floor :

720

-

10080

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supplying & fixing 602 x 602 mm CI man hole frame and cover (light weight) 30 Kgs including cost and conveyance and labour charges for fixing, overheads and contractor profit etc., complete for finished item of work

2

-

7638

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and delivery of encapsulated plastic steps manufactured as per companies standard specification including cost of materials packing as per companiess standards, loading, transportation, unloading and stacking at site of work , and taxes such as complete sales tax,C.E.D and others etc., as applicable including labour charges for fixing etc. complete for finished item of work.

39

-

8658

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and fixing ornamental MS Wicket gate Size 1.50m x 3.00m as per the approved drawing using 75mm x 75mm x 6mm MS angle alround for frame and 63mm x 6mm MS flats in 6 rows horizontally, 25mm MS square vertical bars at 125mm c /c and CI spikes 9" long at the top and 6" long spikes in two rows in the middle, 3 Nos of Pin clamps fixed in RCC columns, providing 2 Nos.of MS powder coated aldrops 300mm long including cost all taxes and conveyance of all materials,fabrication charges welding charges incidental charges all labour charges, overheads and contractor profit etc., complete for finsihed item of work.

7.2

-

57564

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and fixing ornamental MS Main gate of size 9mts x 3.75 mts ( average height) i.e., varying from 3mts to 4.50 mts at centre as per the approved drawing using MS Angle of 75mm x 75mm x 6mm alround for frame and 63mm x 6mm MS Flats in 6 rows horizontally, 25mm MS Square bars at 125mm c/c and CI Spikes 9" long on top and 6" long CI spikes in the middle in two rows including 6 Nos of Pin clamps fixed in RCC Columns, 2 Nos of MS aldrops 450 mm Long ( special ) welded at the the centre on each side, 2 Nos of MS tower bolts 450mm Long ( special )and providing brass emblem on emboseed cover in the centre of the two leaves and fixing 2 Nos. of rollers per each leaf including cost and conveyance of all materials,fabrication charges , welding charges, incidental charges and all labour charges, over heads and contractor profit etc., complete for finsihed item of work.

36

-

143100

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supplying and fixing 50mm dia nominal bore Medium Grade properties & weight as per IS 1239 ISI mark MS Tube for fixing of GI Sheet including cost and conveyance of all materials to work site and all operational, incidental, labour charges , overheads & contractors profit for finished item of work.etc., complete for finished item of work in all floors for stair case head room roof.

129

-

90042

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supplying and fixing of Pre-painted Galvalume Trapezoidal Profile Roofing sheets with 0.50mm thickness, Coating: Alu-Zinc coating AZ150 GSM. Tensile Strength: 550 MPA. Paint coating: Regular Modified Polyester painting. Painting Thickness (Top): 18 to 20 Microns, (Bottom): 5 to 7 Microns. Sheet Width: 1.020, Length: Maximum 12 Meters with Regular Range Colours fixed with G.I ?J? bolts & nuts 8 mm dia with bitumen & G.I limpet washers filled with white lead & including a coat of approved steel primer and two coats of approved paint on over lapping of sheets complete (up to a pitch of 600) etc., complete, excluding the cost of purlins, rafters, trusses including cost and conveyance of all materials , labour charges , overheads and contractors profit etc., complete for finished item of work Head Rooms

253

-

210496

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Providing and fixing of 24 gauge alluminium sheet over expansion joint groove of width 15cm fixed to walls / columns at one edge and resting over the other block walls/columns concealing expansion joint with slotted holes for free edge of aluminium sheet to facilitate free movement of aluminium sheet over the finished surface of expansion joint and wall face using sheet metal screws with nylon receiver complete including cost and conveyance of all materials to site, all incidental, operational, labour charges , overheads & contractors profit etc., complete for finished item of work as per approved drawing (for all floors for vertical joints and bottom of slab) Head Rooms.

64

-

5248

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Providing specialized polysulphide sealant treatment to the expansion joints (Size : 25mm x 12mm) including cost and conveyance of all materials to site, all incidental, operational, labour charges etc.overheads & contractors profit complete for finished item of work as per approved drawing for all floors duly a]. Chipping and removing of existing covering on expansion joints b]. Cleaning of the surface from dirt, dust and other contaminations c].Application of one coat of - High performance specially designed SBR latex polymer based bonding agent d]. Providing and application of Acrylic Polymer modified instatement concrete /mortar to the damaged edges of joint and making the groove. e]. Providing and fixing of masking tape on top of the joint both sides f]. Providing and fixing of Back up support material of Backer rod to leave the depth of 12mm on the joint g]. Providing and application of one coat of polysulphide primer on inner edges of Joint. h]. Providing and application of Two part Polysulphide sealant to a width of 25mm and 12mm depth with putty knife and neat finish i]. Removing of masking tape and providing and application of two coats of Acrylic elastomeric cementitious coating.

64

-

55936

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Providing and fixing of Expansion joint filler board for buildings, columns, beams and slabs 25 mm thick including cost and conveyance of all materials to site, all incidental, operational, labour charges etc.overheads & contractors profit complete for finished item of work as per approved drawing for all floors

30

-

13980

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply & fixing of PVC WATER STOPPER 230mm wide for Expansion joints at slab,including cost & conveyance of material , labour charges & contractors profit.Complete for finished item for work.

57

-

12540

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supplying and fixing Gyp Board Suspended regular single layer false ceiling (GS-MFSC-4.1) using 12.5 mm thick Gyp Board conforming to IS 2095 - 1993 fixing to Gyp steel GI perimeter channels of size 20 mm x 27 mm x 30 mm(web) of 0.55 mm thick along the perimeter of ceiling screw fixed to brick work/ partition at 610 mm c/c and suspending the frame work using Intermediate channels (45 mm x 15mm x 15mm x 0.9 mm) from soffit at 1220 mm c/c with ceiling angle (25 mm x 10 mm x 0.55 mm) fixed with GI Cleat and steel expansion fasteners & connecting clip to the ceiling channels (with knurled web of 51.5 mm x 26 mm x 10.5 mm x 0.55 mm) fixed in direction perpendicular to the intermediate channel at 457 mm c/c and fixing the 12.5 mm tapered edge Gypboard with 25 mm drywall screws at 230 mm c/c & jointing and finishing using joint compound and paper tape to have a flush look including filling the tapered & square edges with jointing compound, two coats of drywall topcoa including overheads and contractor profit etc., complete for finished item of work.

4259.11

-

5191853

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Providing and fixing in true horizontal level 14 mm - Mineral Fiber sheet 595 x 595 (Square / Tegular) Fissura fine model edge tiles with a Humidity Resistance of 90% RH,Average NRC 0.50, Light Reflectance >80%, Thermal Conductivity ?= 0.052 to 0.057 w/mk, Fire Performance Class 0/Class 1 using hot dipped Galvanized Steel section exposed surface with pre-coated capping, main Tee of size 24 x 32 mm at every 1200 mm c/c maximum and rotary stitched cross tee of size 24 x 27 mm at every 600 mm c/c and sub-cross tee of size 24 mm x 25 mm at 1200 mm c/c and wall angle of size 19 x 19 mm fixed to periphery of the wall and the above grid is suspended at every 1200 mm c/c in both directions using 2.0 mm thick pre-straightened GI Wire including cost and conveyance of all materials and labour charges such as cutting, fixing of standing of frame work exposing roof making, overheads & contractor profit etc., complete for finished item of work in all floor in all floors.

1487

-

1982171

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply & fixing of Rolling shutter made of 80 x 1.25 mm machine rolled CRCA laths, interlocked together through their entire length and jointed together at the ends by end-locks, mounted on specially designed pipe shaft of 50mm dia nominal bore MS B class pipe with brackets, plates, guide channels, stoppers, bottom locking plates and arrangements for inside & outside locking with push-pull operations including cost of hood cover and springs complete, painted with one coat of approved steel primer, locks, ball bearings, all accessories etc., overheads & contractors profit complete for finished item of work as per special spn: 1108

14.04

-

70677

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supplying and fixing of two shutter cupboards as per drawing with medium teak wood frames of size 75mm x 40mm and MDF Board Interior grade both sides laminated 18mm thick for shutters with 18mm x 12mm teak wood beading alround and supplying and fixing Continuous Piano Hinges Powder coated Mild steel as per IS-3818 : 1992 of nominal size 25mm (B) of thickness 0.8 to 1.0 mm, Stainless Steel Tower Bolt-10 mm Bolt(IS:15833) 100 mm Long, 4 Nos of Stainless Steel Door Handles 100 mm Long and standard locking arrangements and magnets for shutters including cost and conveyance of all materials to site, labour charges, over heads and contractor profit etc., complete for finished item of work.

501

-

1957908

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Painting two coats with synthetic enamel paint Grade-II VOC (Volatile Organic Compound) content less than 50 grams/litre over primer coat of red oxide to new iron work including cost and conveyance of all materials to site, sales & other taxes, incidental, operational and all labour charges etc., and overheads & contractors profit complete for finished item of work in all floors. (SS No. 1201, 1212 & 1207).

2594

-

474702

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply & applying Melamine Polish Glossy/ Matt finish to the wood works duly cleaning the surface and applying emery paper, Sand the wood with 180 No., emery paper and then with 320 No., emery paper, clean & wipe off loose dust, applying suitable knifing paste filler / wood filler by putty knife / muslin pad, air dry for 2 - 3 hrs, sand with 180 and 320 No., emery paper, apply two component wood sealer, air dry for 24 hrs, Sand with 320 No emery paper, applying one coat of approved spraying thinner (for spraying)/ applying one coat of approved brushing thinner or general purpose thinner (for brushing) and apply (either with spray or brush) two coats of approved brand melamine including cost & labour charges, emery papers, cost of thinner & melamine polish, over heads and contractors profit etc., complete for finished item of work. for All Floors

36

-

44532

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Painting to new wood work and flush shutters with lappam finish, over a primary coat and painting two coats of synthetic enamel paint Grade-II VOC (Volatile Organic Compound) content less than 50 grams/litre of approved shade including cost and conveyance of all materials to site cost of primer coat and all labour charges etc. complete including applying sand paper on lappam coats for neat finish including sales & other taxes on cost of all materials etc., and overheads & contractors profit complete in all floors (APSS No.1200, 1207 & 1211). For All Floors

926

-

198164

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Providing and applying Exterior grade Texture ready mixed paint with sand texture added sand particles Acrylic copolymers and mineral compounds, bactericides and various additives of average 2 to 3 mm thickness over plastered surface to prepare the surface even and smooth after thoroughly brushing the surface to remove all dirt and remains of loose powdered materials, applying emery paper, Sand the surface, clean & wipe off loose dust, applying putty/ texture paint filler by putty knife / muslin pad, air dry for 2 - 3 hrs for the surface preparation including cost and conveyance of all materials to work site and all operational, incidental, labour charges, scaffolding charges, overheads and contractors profit etc., complete for finished item of work in all floors for external walls.

686.2

-

219584

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply & application of one coat water based cement primer of exterior grade II and two coats of acrylic emulsion paint exterior grade with silicon additives having VOC (Volatile Organic Compound) content less than 50 grams/ liter for exterior walls including cost and conveyance of all materials to site, sales & other taxes, incidental, operational and all labour charges etc., and overheads & contractors profit complete for finished item of work in all floors.

9826

-

2741454

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply & application of one coat water based cement primer of interior grade I and two coats of acrylic emulsion paint having VOC (Volatile Organic Compound) content less than 50 grams/litre for internal walls including cost and conveyance of all materials to site, sales & other taxes, incidental, operational and all labour charges etc., and overheads & contractors profit complete for finished item of work in all floors.

16837

-

3232704

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Providing and applying Wall putty of White Cement or Polymer or Cement based of average 1 to 2 mm thickness over plastered surface to prepare the surface even and smooth after thoroughly brushing the surface to remove all dirt and remains of loose powdered materials, applying emery paper, Sand the surface, clean & wipe off loose dust, applying knifing paste filler by putty knife / muslin pad, air dry for 2 - 3 hrs, sand with 180 and 320 No., emery paper for the surface preparation including cost and conveyance of all materials to work site and all operational, incidental, labour charges, over heads and contractors profit etc., complete for finished item of work in all floors for Internal walls.

2674

-

652456

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;White washing two coats with white cement to ceiling to give an even shade after thouroughly brushing the surface to remove all dirt and remains of loose powdered materials including cost of all materials, labour charges and incidental such as scaffolding, lift charges etc., and overheads & contractors profit complete for finished item of work in all floors.

9932

-

466804

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;RCM facia 50mm thick in CM (1:3) using screened sand for drop walls, fins with rabbit wire mesh & nomianl reinforcement as directred by Engineer - In - Charge with dubara sponge finishing,including cost and conveyance of all materials to site, sales & othertaxes on all materials, operationals &incidental, cost and conveyance of cement, wire mesh, water to work site, centering, scaffolding and form work,lift charges etc., and overheads & contractors profit complete for finished item of work but excluding cost of steel and its fabrication charges for finished item of work (APSS NO.403&903). Third Floor :

10

-

32040

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;RCM facia 50mm thick in CM (1:3) using screened sand for drop walls, fins with rabbit wire mesh & nomianl reinforcement as directred by Engineer - In - Charge with dubara sponge finishing,including cost and conveyance of all materials to site, sales & othertaxes on all materials, operationals &incidental, cost and conveyance of cement, wire mesh, water to work site, centering, scaffolding and form work,lift charges etc., and overheads & contractors profit complete for finished item of work but excluding cost of steel and its fabrication charges for finished item of work (APSS NO.403&903). Second Floor :

10

-

30540

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;RCM facia 50mm thick in CM (1:3) using screened sand for drop walls, fins with rabbit wire mesh & nomianl reinforcement as directred by Engineer - In - Charge with dubara sponge finishing,including cost and conveyance of all materials to site, sales & othertaxes on all materials, operationals &incidental, cost and conveyance of cement, wire mesh, water to work site, centering, scaffolding and form work,lift charges etc., and overheads & contractors profit complete for finished item of work but excluding cost of steel and its fabrication charges for finished item of work (APSS NO.403&903). Ground Floor/ First Floor :

30

-

87150

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supplying and fixing of stainless steel (grade 304) 50mm dia pipe and 2mm thick medium class Grip bar along the Ramp flight/Staircase Flight as per approved drawing including cost and conveyance of all materials to site, buffing charges, polishing charges, overheads & contractors profit etc complete for finished item of work. for All Floors

173

-

292197

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supplying and fixing of stainless steel (grade 304) hand railing as per approved drawing with top rail of 50mm dia pipe and 2mm thick medium class and vertical posts of 25mm dia and 1.6mm thick medium class 2 Nos for each step fixed with base plate of 75mm dia using bonding agent and anchor fastner and welding, drilling of 25mm dia holes with pneumatic compressor for fixing railing, buffing, polishing all members of the railing thouroughly, lacquer finishing to present seamless finish including cost and conveyance of all materials, electrodes, welding charges, cost of all consumables, labour charges, overheads & contractors profit etc., complete for finished item of work. For All Floors

128

-

788736

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supplying and fixing of MS Grill to windows / in open court yards using 25mm x 6mm MS flat alround and 10mm MS square bars horizontally at 125mm centre to centre and vertically at 300mm centre to centre including fixing with 4 Nos of MS Z holdfasts (2 on each side) duly making cutting brick masonry, fixing and making to original surface neatly and painting grill with one coat of red oxide primer including cost all taxes and conveyance of all materials including cutting, bending, welding including all operational charges and all labour charges etc., complete for finished item of work. for all Floors

2540

-

3622040

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Providing and Fixing Structural Glazing fabricated from Roll formed sections made of Pre-painted Steel / Powder coated (Base steel as per IS 513 of ?D? quality, galvanized as per IS 277 with Zinc of 120 Gm/Sqm) with total coated thickness of 0.72mm. The glass holding section made of 304 grade stainless steel of 0.6mm thick as per the design requirement & calculations as given in IS: 875. Primer coat with epoxy primer of 5 ? 7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with Alkyd backer of 5-7 microns or powder coated with pure polyester powder up to 50-60 microns thick. The vertical section should be of 50mm x100mm x 0.72mm, 33mm x 58mm x 0.72mm for frame horizontal section, stiffener section should be 48mm x 98mm x 1mm, cover profiles sections should be of 20mm x 58mm x 0.58mm, Glass holding section should be of 37mm x 37mm & 37mm x 18mm. Including 5mm thick Ocean Blue reflective glass. Brackets made of CRCA powder coated/Electroplated should be used to connect vertical to horizontal, vertical to slab, to fix verticals at top & bottom as per site requirement. Gasket made of Ethyl Propylene Diamine Monomer. Natural cure, with Good U.V. Resistance Silicon to be used. Wall fixing of sections to concrete/ masonry wall should be with self-expanding cap & screws. The rate is inclusive of cost and conveyance of all materials to site, all labour charges, incidental charges, cost of all consumables etc. and scaffolding charges, form work , overheads & contractors profit etc., complete for finished item of work in all floors.

42

-

395094

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Providing, supplying & fixing of Fixed Louvered Ventilator made out of multi chambered uPVC sections with Glazing bead shall be co-extruded with Grey colour soft PVC. having isolated drainage and reinforced with Galvanized Iron profiles throughout the window. The outer frame having an overall size of 60 mm x 55 mm x 2.40 with reinforcement of 1 mm thickness and Mullion with overall size of 74 mm x 60 mm x 2.40 mm with reinforcement of 1 mm thickness. (Composition of profile shall consists a minimum of 5.5 PHR of TiO2 and not more than 12 PHR of CaCo3 for every 100 parts of PVC resin). Ventilator shall be provided with 4.5 mm Pin Head glass, standard hardware. Wall thickness of frame & Mullion shall be 2.4 mm., including cost and conveyance of all materials, accessories, labour charges for transportation, erection at site including overheads and contractor profit etc., complete for finished item of work. for all Floors

107.7

-

783948

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supplying and fixing of Unplasticised Poly Vinyl Chloride (UPVC) Fixed Glazing - 56 series duly manufactured using UPVC reinforced profiles of 60 mm x 56 mm x 2.25 mm for outer frames and the mullion sections are of 60 mm x 70 mm x 2.25 mm frames are structurally reinforced with hot dip galvanized up to 50 microns of minimum thickness of 1.2 mm the sash shall be fitted with 4 mm thick pinheaded glass of reputed make duly fixed with EPDM weathering seal resistant including cost and conveyance of all materials, accessories, labour charges for transportation, erection at site with templates for casement sizing scaffolding including overheads and contractor profit etc., complete for finished item of work.for OTs for All Floors

28

-

148232

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supplying and fixing of Unplasticised Poly Vinyl Chloride (UPVC) sliding doors three track - two glass shutters sliding and one mesh shutter sliding- 95 -Series duly manufactured using UPVC reinforced profiles of (108 mm x 45 mm)/(95.50 mm x 60 mm) x 2.0 mm for outer frames, (75 mm x 39 mm)/(66 mm x 42 mm) x 2.0 mm for sliding door shutter frames capable of mounting single glazing system, structurally reinforced with hot dip galvanized up to 50 microns of minimum thickness of 1.2 mm prefabricated & welded through fusion welding the window sash shall be fitted with 5 mm thick clear float glass of reputed make and mesh shutter shall be made of (48.5 mm x 30 mm))/(50 mm x 26.5 mm) x 2.0 mm UPVC profile section and fitted with nylon/polymer mesh and rollers/pulley duly fixed with TPV Gaskets/ EPDM weathering seal resistant accessories like clipping locking system made of aluminium 1 No., per set of sashes and the system is to be installed at the site using anchor fasteners, silicon rubber sealant, easy glazing/ deglazing at site etc., including cost and conveyance of all materials, accessories, labour charges for transportation, erection at site with templates for casement sizing, overheads and contractors profit etc., complete for finished item of work

301.32

-

2437076

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;SSupplying and fixing of Unplasticised Poly Vinyl Chloride (UPVC) 2 Track?2 Panel Sliding windows duly manufactured using UPVC reinforced profiles (Composition of profile shall consists a minimum of 5.5 PHR of TiO2 and not more than 12 PHR of CaCo3 for every 100 parts of PVC resin) of (62mm x 60 mm)/(60 mm x 45 mm) x 2.20 mm for outer frames, (66 mm x 38 mm)/(58 mm x 39 mm) x 2.20 mm for sliding shutter frames capable of mounting single glazing system, structurally reinforced with hot dip galvanized up to 50 microns of minimum thickness of 1.0/1.2 mm prefabricated & welded through fusion welding. The window sash shall be fitted with 5 mm thick clear float glass of reputed make duly fixed with Grey colour TPV Gasket for sash & Glazing bead shall be co-extruded with Grey colour soft PVC. System shall have single point locking with Touch Lock and the system is to be installed at the site using anchor fasteners, silicon rubber sealant, easy glazing/ deglazing at site etc., including cost and conveyance of all materials, accessories, labour charges for transportation, erection at site including overheads and contractors profit etc., complete for finished item of work. For All Floors

2236.53

-

17324161

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supplying and fixing of Unplasticised Poly Vinyl Chloride (UPVC) sliding doors three track - two glass shutters sliding and one mesh shutter sliding- 95 -Series duly manufactured using UPVC reinforced profiles of (108 mm x 45 mm)/(95.50 mm x 60 mm) x 2.0 mm for outer frames, (75 mm x 39 mm)/(66 mm x 42 mm) x 2.0 mm for sliding door shutter frames capable of mounting single glazing system, structurally reinforced with hot dip galvanized up to 50 microns of minimum thickness of 1.2 mm prefabricated & welded through fusion welding the window sash shall be fitted with 5 mm thick clear float glass of reputed make and mesh shutter shall be made of (48.5 mm x 30 mm))/(50 mm x 26.5 mm) x 2.0 mm UPVC profile section and fitted with nylon/polymer mesh and rollers/pulley duly fixed with TPV Gaskets/ EPDM weathering seal resistant accessories like clipping locking system made of aluminium 1 No., per set of sashes and the system is to be installed at the site using anchor fasteners, silicon rubber sealant, easy glazing/ deglazing at site etc., including cost and conveyance of all materials, accessories, labour charges for transportation, erection at site with templates for casement sizing, overheads and contractors profit etc., complete for finished item of work for all Floors

10.08

-

80721

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Providing & Fixing of Scientific Doors with metal door frames and door shutters made of galvanize steel (base steel as per IS 513 of 0.58 mm thick D quality, galvanized as per IS 277 with Zinc of 120 GSM) coated with Zinc Phosphate Primer to receive any paint on site or finished with Thermosetting Polyurethane paint of Aliphatic Grade providing high levels of scratch resistance and durability/Epoxy polyester powder for powder coating paint thickness 50-60 microns (Dry film thickness) outer frame section of 100 x 58 mm x 1.2 mm thick, shutter section of 0.80 mm thick galvanized steel sheet pressed (roll formed) for 46mm thick fully flush, double skin door shell seam joints at stile edges, in-fill of honeycomb kraft paper used to give the required rigidity and effective acoustic insulation with 6? Tower bolt ? 2 Nos., 6? D handles ? 2 Nos., 10? Aldrop ? 1 No., Butt Hinges ? 6 Nos, Mortise Lock ofapproved quality ? 1 No, frames fixed to the concrete/masonry wall by means of self expanding screws including overheads and contractor profit etc., complete for finished item of work for Double leaf Door. For all Floors

15.68

-

221922

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and fixing of Cement Bonded Prelaminated Particle Board aluminum glazed partitions using 10mm Cement Bonded Prelaminated Particle Board and 5.00mm thick plain glass to full height. Using with Cement Bonded Prelaminated Particle Board to a height of 0.91 meter at bottom panel and remaining height with glass and aluminum sections anodized to 12 to 15 microns and of sections of size 37mm x 62mm and 1.5mm thickness with one meter centre to centre duly fixed with clip beading on both sides including fixing the frame to pillars by M.S. flats, bolts and nuts including cost and conveyance of all materials etc., complete as directed during execution including overheads & contractors profit etc., complete for finished item of work for all Floors

1147

-

5252113

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply & Fixing of Powder Coated Fire Rated doors, frames & shutters made of Skin pass galvanized Iron sheet conforming to Base Steel as per IS 513 ?D? Quality, Galvanized as per IS 277 with Hot Zinc Coating of 120 grams / Sq.Mtr with powder coating of thickness 60-65 Microns, frame with 1.2mm thick Skin pass Galvanized Iron sheet formed to double rebate profile of size 143 mm X 58 mm with maximum bending radius of 1.4 mm and filled with in-fill Polyurethane foam, the Door Shutters are with 0.80 mm thick Skin pass Galvanized Iron Sheet formed to provide a 46 mm thick fully flush,double skin door shell with Lock Seam joints at stile edges, fitted with in-fill of Honeycomb Kraft Paper and coated with polyester powders of Pure polyester/ epoxy polyester or polyurethane powder for powder coating of thickness 60 ? 65 microns and are coated with Zinc Phosphate Primer to receive any paint on site or finished with Thermosetting Polyurethane paint of Aliphatic Grade providing high levels of scratch resistance and durability, the Shutter provided with 6 MM clear float vision glass in Circular, Square or Rectangular shapes, Stainless Steel Ball Bearing Butt Hinges 3 mm thick fixed flush to the frame and shutter (Profile 102x76x3mm thick).Mortise Sash Lock with Lever Handles, Mortise Dead Bolt, etc for 120 minutes Fire Rated door conforming to IS:3614 (Part2) 1992 including overheads and contractor profit etc., complete for finished item of work For All Floors

148.05

-

2260427

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and fixing powder coated aluminium fully glazed swing door as per the approved drawing with fixed fan light of 500mm height at top door using aluminium sections of 101.60 mmm x 44.45mm , 3.18 mm thick for frame and door shutter made of styles , top and middle rail of 47.62mm x 44.45mm , 3.18 mm thick and bottom rail of 114.30mm x 44.45 mm , 3.18mm thick,powder coating of alluminium sections 25mm microns thick, 5 mm thick plain float glass fitted with suitable aluminium glazing clips and rubber beading in fan light portion, double shutters fitted with 5mm thick frosted / ground glass in the top half and 12mm thick prelaminated particle board (One side choice colour and other side balancing white lamnation) in the bottom half fitted with suitable aluminium glazing clips and rubber beading,shutters mounted on double action hydraulic floor spring of approved brand manufacture IS : 6315 marked, Hardwyn make M-3000 for doors including cost of cutting floors as required, embedding in floors and SS cover plates with brass pivot and sigle piece MS Sheet outer box with slide plate etc.complete (Weight Capacity up to 130 Kgs) as approved by Engineer-in-Charge including supply and fixing ISI marked powder coated aluminium fixtures of 4 Nos.tower bolts 10mm bolt (IS:204) 300mm long, 4 Nos.alluminium handles (IS:208) 150mm dia and 2 Nos. aldrops (IS:2681) 300mm long including labour charges for manufacturing door , fixing the door with required No. of screws etc., including overheads & contractors profit complete for finished item of work. (The Aluminium section used shall be standard make confirming to IS 1948 ? 1961) and as approved by the Engineer) (1800mm x 2600mm). For All Floors

366.6

-

2977159

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and fixing doors as per drawings with medium teak wood frame of section 100mm x 65mm and ISI marked flush door shutter of 30mm thick single shutter with bond wood solid block board type Core having cross bands and face veneers, hot pressed bonded with water proof phenol formaldehyde synthetic resin factory made conforming to IS 2202-1991 (Part-I) both sides commercial ply with internal lipping on all sides including cost and conveyance to site of medium teak wood door frame, flush shutter, including suply and fixing 6 Nos. MS Z hold fasts of size 300mm x 40mm x 5mm including ISI marked Aluminium fixtures 3 Nos. butt hinges (IS:205) of 150mm long, 1 No. aldrop (IS:2681) 250 mm long, 1 No. tower bolt (IS:204) of 150 mm x 10mm dia, 2 Nos. 125mm long handles (IS:208), 1 No. rubber bush including supplying and fixing 1.20mm thick PVC sheet to full height of the shutter inside including labour charges for fixing the frame in position, fixing the shutter to the frame etc., including overheads & contractors profit complete for finished item of work as per APSS 1001 & 1002. (The vertical frame of door shall be embedded in flooring for deth of not less than 10mm) (800mm x 2100mm). for All Floors

415.91

-

2157299

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and fixing doors as per drawings with medium teak wood frame of section 100mm x 65 mm and ISI marked flush door shutters of 30 mm thick single shutter with bond wood solid block board type Core having cross bands and face veneers, hot pressed bonded with water proof phenol formaldehyde synthetic resin factory made conforming to IS 2202-1991 (Part-I) both sides commercial ply with internal lipping on all sides including cost and conveyance to site of teak wood frame, flush shutter including supply and fixing 6 Nos. MS Z hold fasts of size 300 mm x 40 mm x 5mm including cost of ISI marked Aluminium fixtures of 3 Nos. butt hinges (IS:205) 150mm long, 1 No. aldrop (IS:2681) 300mm long, 1 No. tower bolt (IS:204) of 200 mm x 10 mm dia at top, 2 Nos. 150 mm long handles (IS:208), 1 No. door stopper and 1 No. rubber bush including fixing the fixtures to door with required number of screws, bolt and nuts including labour charges for fixing the frame in position, fixing the shutter to the frame etc, including overheads & contractors profit complete for finished item of work as per APSS 1001 & 1002 (The vertical frame of door shall be embedded in flooring for a depth of not less than 10 mm) (900mm x 2100mm). for All Floors

124.85

-

598032

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and fixing doors as per drawings with medium teak wood frame of section 100mm x 65 mm and ISI marked flush door shutters of 30 mm thick single shutter with bond wood solid block board type Core having cross bands and face veneers, hot pressed bonded with water proof phenol formaldehyde synthetic resin factory made conforming to IS 2202-1991 (Part-I) both sides commercial ply with internal lipping on all sides including cost and conveyance to site of teak wood frame, flush shutter including supply and fixing 6 Nos. MS Z hold fasts of size 300 mm x 40 mm x 5mm including cost of ISI marked Aluminium fixtures of 3 Nos. butt hinges (IS:205) 150mm long, 1 No. aldrop (IS:2681) 300mm long, 1 No. tower bolt (IS:204) of 200 mm x 10 mm dia at top, 2 Nos. 150 mm long handles (IS:208), 1 No. door stopper and 1 No. rubber bush including fixing the fixtures to door with required number of screws, bolt and nuts including labour charges for fixing the frame in position, fixing the shutter to the frame etc., including overheads & contractors profit complete for finished item of work as per APSS 1001 & 1002 (The vertical frame of door shall be embedded in flooring for a depth of not less than 10 mm) (1000mm x 2100mm) For All Floors

53.9

-

245083

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and fixing of doors as per approved drawings with medium teak wood frame of section 100mm x 65 mm with split type fan light of 500mm at the top fixed with 4mm thick pin headed glass using 12mm x 12mm Teak Wood beading and 2 Nos. of 10mm MS Square bars and ISI marked flush door shutter of 30mm thick single shutter with bond wood solid block board type core having cross bands and face veneers, hot pressed bonded with water proof phenol formaldehyde synthetic resin factory made conforming to IS 2202-1991 (Part-I) both sides commercial ply with internal lipping on all sides including cost and conveyance to site of teak wood frame, flush shutter including supply and fixing 6 Nos. MS Z hold fasts of size 300 mm x 40 mm x 5mm including cost of ISI marked Aluminium fixtures of 3 Nos. butt hinges (IS:205) 150mm long , 1 No. aldrop (IS:2681) 300mm long, 1 No. tower bolt (IS:204) of 200 mm x 10 mm dia at top, 2 Nos. 150mm long handles (IS:208), 1 No. door stopper and 1 No. rubber bush including fixing the fixtures to door with required number of screws, bolt and nuts including labour charges for fixing the frame in position, fixing the shutter to the frame, fixing glass in fan light portion etc, including overheads & contractors profit complete for finished item of work as per APSS 1001 & 1002 (The vertical frame of door shall be embedded in flooring for a depth of not less than 10 mm) (900mm x 2600mm). For All Floors

1.9

-

9002

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and fixing of doors as per approved drawings with medium teak wood frame of section 100mm x 65 mm with split type fan light of 500mm at the top fixed with 4mm thick pin headed glass using 12mm x 12mm Teak Wood beading and 2 Nos. of 10mm MS Square bars and ISI marked flush door shutter of 30mm thick double shutters with bond wood solid block board type core having cross bands and face veneers, hot pressed bonded with water proof phenol formaldehyde synthetic resin factory made conforming to IS 2202-1991 (Part-I) both sides commercial ply with internal lipping on all sides, including cost and conveyance to site of teak wood frame, flush shutter including supply and fixing 6 Nos. MS Z hold fasts of size 300 mm x 40 mm x 5mm including cost of ISI marked Aluminium fixtures of 6 Nos. butt hinges (IS:205) 150mm long, 1 No. aldrop (IS:2681) 300mm long, 2 Nos. tower bolts (IS:204) of 200 mm x 10 mm dia at top, 2 Nos. 150mm long handles (IS:208), 2 Nos. door stoppers and 2 Nos. rubber bushes including fixing the fixtures to door with required number of screws, bolt and nuts including labour charges for fixing the frame in position, fixing the shutter to the frame, fixing glass in fan light portion etc, including overheads & contractors profit complete for finished item of work as per APSS 1001 & 1002 (The vertical frame of door shall be embedded in flooring for a depth of not less than 10 mm) (1200mm x 2600mm). For All Floors

80.88

-

362423

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and fixing of doors as per approved drawings with medium teak wood frame of section 100mm x 65 mm with split type fan light of 500mm at the top fixed with 4mm thick pin headed glass using 12mm x 12mm Teak Wood beading and 2 Nos. of 10mm MS Square bars and ISI marked flush door shutter of 30mm thick double shutters with bond wood solid block board type core having cross bands and face veneers, hot pressed bonded with water proof phenol formaldehyde synthetic resin factory made conforming to IS 2202-1991 (Part-I) both sides commercial ply with internal lipping on all sides, including cost and conveyance to site of teak wood frame, flush shutter including supply and fixing 6 Nos. MS Z hold fasts of size 300 mm x 40 mm x 5mm including cost of ISI marked Aluminium fixtures of 6 Nos. butt hinges (IS:205) 150mm long, 1 No. aldrop (IS:2681) 300mm long, 2 Nos. tower bolts (IS:204) of 200 mm x 10 mm dia at top, 2 Nos. 150mm long handles (IS:208), 2 Nos. door stoppers and 2 Nos. rubber bushes including fixing the fixtures to door with required number of screws, bolt and nuts including labour charges for fixing the frame in position, fixing the shutter to the frame, fixing glass in fan light portion etc., including overheads & contractors profit complete for finished item of work as per APSS 1001 & 1002 (The vertical frame of door shall be embedded in flooring for a depth of not less than 10 mm) (1500mm x 2600mm). For All Floors

156

-

640380

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and fixing of doors as per approved drawings with medium teak wood frame of section 100mm x 65 mm with fixed fan light of 500mm at the top fixed with 4mm thick pin headed glass using 12mm x 12mm Teak Wood beading and 2 Nos. of 10mm MS Square bars and ISI marked flush door shutter of 30mm thick double shutters with bond wood solid block board type core having cross bands and face veneers, hot pressed bonded with water proof phenol formaldehyde synthetic resin factory made conforming to IS 2202-1991 (Part-I) both sides commercial ply with internal lipping on all sides including cost and conveyance to site of teak wood frame, flush shutter including supply andfixing 6 Nos. MS Z hold fasts of size 300 mm x 40 mm x 5mm including cost of ISI marked Aluminium fixtures of 6 Nos. butt hinges (IS:205) 150mm long, 1 No. aldrop (IS:2681) 300mm long, 2 Nos. tower bolts - 10mm (IS:204) of 200 mm long at top, 2 Nos. 150mm long handles (IS:208), 2 Nos. door stoppers and 2 Nos. rubber bushes including fixing the fixtures to door with required number of screws, bolt and nuts including labour charges for fixing the frame in position, fixing the shutter to the frame, fixing glass in fan light portion etc., including overheads & contractors profit complete for finished item of work as per APSS 1001 & 1002 The vertical frame of door shall be embedded in flooring for a depth of not less than 10 mm) (1800mm x 2600mm). For All Floors

16.08

-

61967

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and fixing of two shutter main door cum fixed window as per approved drawing with best teak wood frame of section 150mm x 100 mm with fixed fan light of 500mm at top and fixed panels of 600mm width at sides fixed with 12mm thick Tinted - Bronze/Green glass using 12mm x 12mm teak wood beading and fixing ornamental grill made of 25mm x 5mm MS flats as per the approved drawing in fan light portion and fixed panels and 1st class teak wood top and middle rails & styles of section 120mm x 35mm, bottom rail of size 150mm x 35mm and 12mm thick plain float glass for shutter with ornamental etching including cost and conveyance to site of teak wood frame, shutters, glass including supply and fixing 6 nos MS Zhold fasts of size 300 mm x 40 mm x 5mm including cost of ISI marked brass fixtures of 8 Nos butt hinges (IS:205) 250mm long, 1 No. aldrop (IS:2681) 450mm long, 3 Nos tower bolts- 10mm (IS:204) of 200 mm long , 2 Nos 450 mm long fancy handles, 2 Nos door stoppers including fixing the fixtures to door with required number of screws, bolt and nuts including labour charges for fixing the frame in position, fixing the shutters to the frame, fixing glass in fan light portion etc., including overheads & contractors profit complete for finished item of work as per APSS 1001 & 1002 (The vertical frame of door shall be embedded in flooring for a depth of not less than 40 mm) (3000mm x 2600mm). Ground Floor/ First Floor :

15.6

-

185156

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Providing 160 mm Dia ISI marked PVC down water take pipes with socket , 2.5mm thick 4.0 kg/sq.cm pressure of ISI marked including cost of necessary PVC Bends, shoes, iron / PVC clamps and all other accessories and fixing in position including cost and conveyance of all materials, sales & other taxes on materials to site, operational & incidental charges including all labour charges for fixing at site etc., and overheads & contractors profit complete for finished item of work. (APSS No. 1328)

487.6

-

258916

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Providing skirting to internal walls 10cm height with High Polished Granite 16 to 18 mm thick up to 8'-00 (2.43 M) other than black and regular colours, length equal to flooring slabs set over base coat of CM(1:5) 12 mm thick using screened sand with cement slurry of honey like consistency spread at the rate of 3.30 kgs per sqm and jointing with white cement paste mixed with pigment of matching shade to full depth, including cost of all materials like tiles, cement, sand and water etc., and overheads & contractors profit complete for finished item of work. Third Floor :

46

-

31556

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Providing skirting to internal walls 10cm height with High Polished Granite 16 to 18 mm thick up to 8'-00 (2.43 M) other than black and regular colours, length equal to flooring slabs set over base coat of CM(1:5) 12 mm thick using screened sand with cement slurry of honey like consistency spread at the rate of 3.30 kgs per sqm and jointing with white cement paste mixed with pigment of matching shade to full depth, including cost of all materials like tiles, cement, sand and water etc., and overheads & contractors profit complete for finished item of work. Second Floor :

74

-

50246

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Providing skirting to internal walls 10cm height with High Polished Granite 16 to 18 mm thick up to 8'-00 (2.43 M) other than black and regular colours, length equal to flooring slabs set over base coat of CM(1:5) 12 mm thick using screened sand with cement slurry of honey like consistency spread at the rate of 3.30 kgs per sqm and jointing with white cement paste mixed with pigment of matching shade to full depth, including cost of all materials like tiles, cement, sand and water etc., and overheads & contractors profit complete for finished item of work. Ground Floor/ First Floor :

74

-

49654

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Providing skirting to internal walls to 10.00 cm height with Polished Shahabad/Tandur stone slabs 15mm to 18mm thick, length equal to flooring stones set over base coat of CM(1:5) 12 mm thick using screened sand with cement slurry of honey like consistency spread at the rate of 3.30 kgs per sqm and jointing with white cement paste mixed with pigment of matching shade to full depth, including cost of all materials like tiles, cement, sand and water etc., complete and overheads & contractors profit complete for finished item of work.(APSS No.701 &707) Ground Floor/ First Floor :

55

-

4840

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Providing skirting to internal walls up to 10 cm height with with Nano polished /stain free soluble salt porcelain vitrified tiles screen printed of size 600 x 600 mm and thickness between 8-10 mm 1st quality conforming to IS:13711, IS:13712, IS:13630 (Parts 1 to 15) of any colour and finish in all shades and designs, length equal to flooring tiles, set over base coat of CM(1:5) 12 mm thick using screened sand with cement slurry of honey like consistency spread at the rate of 3.30 kgs per sqm and jointing with white cement paste mixed with pigment of matching shade to full depth, including cost of all materials like tiles, cement, sand and water etc., and overheads & contractors profit complete for finished item of work. (APSS No.701 &707). Third Floor :

249

-

29631

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Providing skirting to internal walls up to 10 cm height with with Nano polished /stain free soluble salt porcelain vitrified tiles screen printed of size 600 x 600 mm and thickness between 8-10 mm 1st quality conforming to IS:13711, IS:13712, IS:13630 (Parts 1 to 15) of any colour and finish in all shades and designs, length equal to flooring tiles, set over base coat of CM(1:5) 12 mm thick using screened sand with cement slurry of honey like consistency spread at the rate of 3.30 kgs per sqm and jointing with white cement paste mixed with pigment of matching shade to full depth, including cost of all materials like tiles, cement, sand and water etc., and overheads & contractors profit complete for finished item of work. (APSS No.701 &707).Second Floor :

462

-

53130

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Providing skirting to internal walls up to 10 cm height with with Nano polished /stain free soluble salt porcelain vitrified tiles screen printed of size 600 x 600 mm and thickness between 8-10 mm 1st quality conforming to IS:13711, IS:13712, IS:13630 (Parts 1 to 15) of any colour and finish in all shades and designs, length equal to flooring tiles, set over base coat of CM(1:5) 12 mm thick using screened sand with cement slurry of honey like consistency spread at the rate of 3.30 kgs per sqm and jointing with white cement paste mixed with pigment of matching shade to full depth, including cost of all materials like tiles, cement, sand and water etc., and overheads & contractors profit complete for finished item of work. (APSS No.701 &707). Ground Floor/ First Floor :

832

-

91520

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Providing cladding to walls with High Polished Granite 16 to 18 mm thick up to 8'-00 (2.43 M) other than black and regular colours, length equal to flooring slabs set over base coat of CM(1:5) 12 mm thick using screened sand with cement slurry of honey like consistency spread at the rate of 3.30 kgs per sqm and jointing with white cement paste mixed with pigment of matching shade to full depth, including cost of all materials like tiles, cement, sand and water etc., and overheads & contractors profit complete for finished item of work. Third Floor :

6

-

26268

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Providing cladding to walls with High Polished Granite 16 to 18 mm thick up to 8'-00 (2.43 M) other than black and regular colours, length equal to flooring slabs set over base coat of CM(1:5) 12 mm thick using screened sand with cement slurry of honey like consistency spread at the rate of 3.30 kgs per sqm and jointing with white cement paste mixed with pigment of matching shade to full depth, including cost of all materials like tiles, cement, sand and water etc., and overheads & contractors profit complete for finished item of work.Second Floor :

12

-

51912

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Providing cladding to walls with High Polished Granite 16 to 18 mm thick up to 8'-00 (2.43 M) other than black and regular colours, length equal to flooring slabs set over base coat of CM(1:5) 12 mm thick using screened sand with cement slurry of honey like consistency spread at the rate of 3.30 kgs per sqm and jointing with white cement paste mixed with pigment of matching shade to full depth, including cost of all materials like tiles, cement, sand and water etc., and overheads & contractors profit complete for finished item of work. Ground Floor/ First Floor :

35

-

149590

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Providing dadooing to walls with Double charged / multi charged stain free full body porcelain vitrified tiles with double layer pigment of size 600 x 600 mm and thickness between 8-10 mm 1st quality conforming to IS:15622 - 2017, IS:13630 (Parts 1 to 15) of any colour and finish in all shades and designs with borders as approved by Engineer-in-Charge set over base coat of CM(1:5) 12 mm thick using screened sand with cement slurry of honey like consistency spread at the rate of 3.30 kgs per sqm and jointing with white cement paste mixed with pigment of matching shade to full depth, including cost of all materials like tiles, cement, sand and water etc., and overheads & contractors profit complete for finished item of work. (for OT's & LDR) Third Floor :

189

-

177093

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Providing dadooing to walls with Double charged / multi charged stain free full body porcelain vitrified tiles with double layer pigment of size 600 x 600 mm and thickness between 8-10 mm 1st quality conforming to IS:15622 - 2017, IS:13630 (Parts 1 to 15) of any colour and finish in all shades and designs with borders as approved by Engineer-in-Charge set over base coat of CM(1:5) 12 mm thick using screened sand with cement slurry of honey like consistency spread at the rate of 3.30 kgs per sqm and jointing with white cement paste mixed with pigment of matching shade to full depth, including cost of all materials like tiles, cement, sand and water etc., and overheads & contractors profit complete for finished item of work. (for OT's & LDR) Ground Floor/ First Floor :

80

-

73040

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Providing dadooing to walls with glazed full body porcelain wall tiles of size 300 x 600 mm with any type of design texture such as marble finish, wooden, bamboo, stone finishes etc., scratch less, stain free and thickness between 6-8 mm 1st quality conforming to IS:13711, IS:13712, IS:13630 (Parts 1 to 15) of any colour and finish in all shades and designs with borders as approved by Engineer-in-Charge set over base coat of CM(1:5) 12 mm thick using screened sand with cement slurry of honey like consistency spread at the rate of 3.30 kgs per sqm and jointing with white cement paste mixed with pigment of matching shade to full depth, including cost of all materials like tiles, cement, sand and water etc., complete overheads & contractors profit complete for finished item of work.Third Floor :

1767

-

2021448

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Providing dadooing to walls with glazed full body porcelain wall tiles of size 300 x 600 mm with any type of design texture such as marble finish, wooden, bamboo, stone finishes etc., scratch less, stain free and thickness between 6-8 mm 1st quality conforming to IS:13711, IS:13712, IS:13630 (Parts 1 to 15) of any colour and finish in all shades and designs with borders as approved by Engineer-in-Charge set over base coat of CM(1:5) 12 mm thick using screened sand with cement slurry of honey like consistency spread at the rate of 3.30 kgs per sqm and jointing with white cement paste mixed with pigment of matching shade to full depth, including cost of all materials like tiles, cement, sand and water etc., complete overheads & contractors profit complete for finished item of work.Second Floor :

2052

-

2322864

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Providing dadooing to walls with glazed full body porcelain wall tiles of size 300 x 600 mm with any type of design texture such as marble finish, wooden, bamboo, stone finishes etc., scratch less, stain free and thickness between 6-8 mm 1st quality conforming to IS:13711, IS:13712, IS:13630 (Parts 1 to 15) of any colour and finish in all shades and designs with borders as approved by Engineer-in-Charge set over base coat of CM(1:5) 12 mm thick using screened sand with cement slurry of honey like consistency spread at the rate of 3.30 kgs per sqm and jointing with white cement paste mixed with pigment of matching shade to full depth, including cost of all materials like tiles, cement, sand and water etc., complete overheads & contractors profit complete for finished item of work. Ground Floor/ First Floor :

2605

-

2920205

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Providing dadooing to walls with glazed full body ceramic tiles of any size and thickness between 5 to 7mm 1st quality conforming to IS: 13711, IS: 13712, IS: 13630(Parts 1 to 15) of any colour and finish in all shades and designs with borders as approved by Engineer-in-Charge set over base coat of CM(1:5) 12 mm thick using screened sand with cement slurry of honey like consistency spread at the rate of 3.30 kgs per sqm and jointing with white cement paste mixed with pigment of matching shade to full depth, including cost of all materials like tiles, cement, sand and water etc., and overheads & contractors profit complete for finished item of work. (for Toilets). Third Floor :

454

-

384992

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Providing dadooing to walls with glazed full body ceramic tiles of any size and thickness between 5 to 7mm 1st quality conforming to IS: 13711, IS: 13712, IS: 13630(Parts 1 to 15) of any colour and finish in all shades and designs with borders as approved by Engineer-in-Charge set over base coat of CM(1:5) 12 mm thick using screened sand with cement slurry of honey like consistency spread at the rate of 3.30 kgs per sqm and jointing with white cement paste mixed with pigment of matching shade to full depth, including cost of all materials like tiles, cement, sand and water etc., and overheads & contractors profit complete for finished item of work. (for Toilets). Second Floor :

853

-

713108

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Providing dadooing to walls with glazed full body ceramic tiles of any size and thickness between 5 to 7mm 1st quality conforming to IS: 13711, IS: 13712, IS: 13630(Parts 1 to 15) of any colour and finish in all shades and designs with borders as approved by Engineer-in-Charge set over base coat of CM(1:5) 12 mm thick using screened sand with cement slurry of honey like consistency spread at the rate of 3.30 kgs per sqm and jointing with white cement paste mixed with pigment of matching shade to full depth, including cost of all materials like tiles, cement, sand and water etc., and overheads & contractors profit complete for finished item of work. (for Toilets). Ground Floor/ First Floor :

1065

-

877560

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Flooring with 16 to 18 mm thick High Polished Granite stone slabs black colour as approved by the Engineer-in-Charge of length not less than 2.43 mts set over base coat of cement mortar (1:8) , 20mm thick using screened sand over CC bed already laid or RCC roof slab including neat grey cement slurry of honey like consistency spread @ 3.3 Kg per sqm and jointed neatly with white cement paste mixed with pigment of matching shade to full depth including cost and conveyance of all materials like cement , sand , water , granite slabs etc., to work site and all operational, incidental labour & lift charges, half rounding the edge , polishing charges and all other taxes on all materials, cost of base coat and overheads & contractors profit complete for finished item of work for Sill slabs (S.S.701 & special) Third Floor :

89

-

469920

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Flooring with 16 to 18 mm thick High Polished Granite stone slabs black colour as approved by the Engineer-in-Charge of length not less than 2.43 mts set over base coat of cement mortar (1:8) , 20mm thick using screened sand over CC bed already laid or RCC roof slab including neat grey cement slurry of honey like consistency spread @ 3.3 Kg per sqm and jointed neatly with white cement paste mixed with pigment of matching shade to full depth including cost and conveyance of all materials like cement , sand , water , granite slabs etc., to work site and all operational, incidental labour & lift charges, half rounding the edge , polishing charges and all other taxes on all materials, cost of base coat and overheads & contractors profit complete for finished item of work for Sill slabs (S.S.701 & special) Second Floor :

141

-

732072

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Flooring with 16 to 18 mm thick High Polished Granite stone slabs black colour as approved by the Engineer-in-Charge of length not less than 2.43 mts set over base coat of cement mortar (1:8) , 20mm thick using screened sand over CC bed already laid or RCC roof slab including neat grey cement slurry of honey like consistency spread @ 3.3 Kg per sqm and jointed neatly with white cement paste mixed with pigment of matching shade to full depth including cost and conveyance of all materials like cement , sand , water , granite slabs etc., to work site and all operational, incidental labour & lift charges, half rounding the edge , polishing charges and all other taxes on all materials, cost of base coat and overheads & contractors profit complete for finished item of work for Sill slabs (S.S.701 & special) Ground Floor/ First Floor :

155.2

-

792141

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Flooring with 16 to 18mm thick high polished granite stone slabs black colour as approved by the Engineer-in-Charge of length not less than 2.43 mts set over base coat of cement mortar (1:8) , 20mm thick using screened sand over CC bed already laid or RCC roof slab including neat grey cement slurry of honey like consistency spread @ 3.3 Kg per sqm and jointed neatly with white cement paste mixed with pigment of matching shade to full depth including cost and conveyance of all materials like cement , sand , water , granite slabs etc., to work site and all operational, incidental labour & lift charges, half rounding the edge , polishing charges and all other taxes on all materials, cost of base coat and overheads & contractors profit complete for finished item of work for platforms (S.S.701 & special) Third Floor :

73

-

385440

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Flooring with 16 to 18mm thick high polished granite stone slabs black colour as approved by the Engineer-in-Charge of length not less than 2.43 mts set over base coat of cement mortar (1:8) , 20mm thick using screened sand over CC bed already laid or RCC roof slab including neat grey cement slurry of honey like consistency spread @ 3.3 Kg per sqm and jointed neatly with white cement paste mixed with pigment of matching shade to full depth including cost and conveyance of all materials like cement , sand , water , granite slabs etc., to work site and all operational, incidental labour & lift charges, half rounding the edge , polishing charges and all other taxes on all materials, cost of base coat and overheads & contractors profit complete for finished item of work for platforms (S.S.701 & special) Second Floor :

73

-

379016

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Flooring with 16 to 18mm thick high polished granite stone slabs black colour as approved by the Engineer-in-Charge of length not less than 2.43 mts set over base coat of cement mortar (1:8) , 20mm thick using screened sand over CC bed already laid or RCC roof slab including neat grey cement slurry of honey like consistency spread @ 3.3 Kg per sqm and jointed neatly with white cement paste mixed with pigment of matching shade to full depth including cost and conveyance of all materials like cement , sand , water , granite slabs etc., to work site and all operational, incidental labour & lift charges, half rounding the edge , polishing charges and all other taxes on all materials, cost of base coat and overheads & contractors profit complete for finished item of work for platforms (S.S.701 & special) Ground Floor/ First Floor :

127

-

648208

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Providing polished shahabad / Tandur stone slabs of 15mm to 18mm thick in single piece as specified set over a base coat of CM (1:5) , 12mm thick using screened sand over already laid CC bed / RCC roof slab including neat cement slurry of honey like consistency spread @ 3.3 Kgs per Sqm and jointed with neat cement to full depth including cost and conveyance of all materials like cement, sand, water, flooring stones etc. complete including sales & other taxes on all materials including all labour charges like dressing of flooring stones to the required size, flat nosing the edges, mixing of cement mortar, laying, lift charges , cost of base coat, water charges etc., and overheads & contractors profit complete for finished item of work. (APSS No.703 & 701) for treads and risers. Risers of 0.15m height :Ground Floor/ First Floor :

3

-

2652

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Providing polished shahabad / Tandur stone slabs of 15mm to 18mm thick in single piece as specified set over a base coat of CM (1:5) , 12mm thick using screened sand over already laid CC bed / RCC roof slab including neat cement slurry of honey like consistency spread @ 3.3 Kgs per Sqm and jointed with neat cement to full depth including cost and conveyance of all materials like cement, sand, water, flooring stones etc. complete including sales & other taxes on all materials including all labour charges like dressing of flooring stones to the required size, flat nosing the edges, mixing of cement mortar, laying, lift charges , cost of base coat, water charges etc., and overheads & contractors profit complete for finished item of work. (APSS No.703 & 701) for treads and risers. Treads of 0.30m wide : Ground Floor/ First Floor :

4

-

4492

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Providing 16 to 18mm thick high polished granite stone slabs other than black and regular colours (i.e. of shades like paradiso / bala flower / copper silk / laka red / lavender blue) with borders and design as per the pattern approved by the Engineer-in-Charge of length not less than 2.43 mts set over base coat of cement mortar (1:5) , 12mm thick using screened sand over CC bed already laid or RCC roof slab including neat grey cement slurry of honey like consistency spread @ 3.3 Kg per sqm and jointed neatly with white cement paste mixed with pigment of matching shade to full depth including cost and conveyance of all materials like cement , sand , water , granite slabs etc., to work site and all operational, incidental labour & lift charges, half rounding the edges of treads , polishing charges and all other taxes on all materials, cost of base coat and overheads & contractors profit complete for finished item of work for treads and risers (S.S.701 & special). Risers of 0.15m height :Third Floor :

24

-

107184

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Providing 16 to 18mm thick high polished granite stone slabs other than black and regular colours (i.e. of shades like paradiso / bala flower / copper silk / laka red / lavender blue) with borders and design as per the pattern approved by the Engineer-in-Charge of length not less than 2.43 mts set over base coat of cement mortar (1:5) , 12mm thick using screened sand over CC bed already laid or RCC roof slab including neat grey cement slurry of honey like consistency spread @ 3.3 Kg per sqm and jointed neatly with white cement paste mixed with pigment of matching shade to full depth including cost and conveyance of all materials like cement , sand , water , granite slabs etc., to work site and all operational, incidental labour & lift charges, half rounding the edges of treads , polishing charges and all other taxes on all materials, cost of base coat and overheads & contractors profit complete for finished item of work for treads and risers (S.S.701 & special). Risers of 0.15m height : Second Floor :

40

-

177760

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Providing 16 to 18mm thick high polished granite stone slabs other than black and regular colours (i.e. of shades like paradiso / bala flower / copper silk / laka red / lavender blue) with borders and design as per the pattern approved by the Engineer-in-Charge of length not less than 2.43 mts set over base coat of cement mortar (1:5) , 12mm thick using screened sand over CC bed already laid or RCC roof slab including neat grey cement slurry of honey like consistency spread @ 3.3 Kg per sqm and jointed neatly with white cement paste mixed with pigment of matching shade to full depth including cost and conveyance of all materials like cement , sand , water , granite slabs etc., to work site and all operational, incidental labour & lift charges, half rounding the edges of treads , polishing charges and all other taxes on all materials, cost of base coat and overheads & contractors profit complete for finished item of work for treads and risers (S.S.701 & special). Risers of 0.15m height : Ground Floor/ First Floor :

53.4

-

236081

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Providing 16 to 18mm thick high polished granite stone slabs other than black and regular colours (i.e. of shades like paradiso / bala flower / copper silk / laka red / lavender blue) with borders and design as per the pattern approved by the Engineer-in-Charge of length not less than 2.43 mts set over base coat of cement mortar (1:5) , 12mm thick using screened sand over CC bed already laid or RCC roof slab including neat grey cement slurry of honey like consistency spread @ 3.3 Kg per sqm and jointed neatly with white cement paste mixed with pigment of matching shade to full depth including cost and conveyance of all materials like cement , sand , water , granite slabs etc., to work site and all operational, incidental labour & lift charges, half rounding the edges of treads , polishing charges and all other taxes on all materials, cost of base coat and overheads & contractors profit complete for finished item of work for treads and risers (S.S.701 & special). Treads of 0.30m wide : Third Floor :

44

-

299024

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Providing 16 to 18mm thick high polished granite stone slabs other than black and regular colours (i.e. of shades like paradiso / bala flower / copper silk / laka red / lavender blue) with borders and design as per the pattern approved by the Engineer-in-Charge of length not less than 2.43 mts set over base coat of cement mortar (1:5) , 12mm thick using screened sand over CC bed already laid or RCC roof slab including neat grey cement slurry of honey like consistency spread @ 3.3 Kg per sqm and jointed neatly with white cement paste mixed with pigment of matching shade to full depth including cost and conveyance of all materials like cement , sand , water , granite slabs etc., to work site and all operational, incidental labour & lift charges, half rounding the edges of treads , polishing charges and all other taxes on all materials, cost of base coat and overheads & contractors profit complete for finished item of work for treads and risers (S.S.701 & special). Treads of 0.30m wide :Second Floor :

73

-

489684

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Providing 16 to 18mm thick high polished granite stone slabs other than black and regular colours (i.e. of shades like paradiso / bala flower / copper silk / laka red / lavender blue) with borders and design as per the pattern approved by the Engineer-in-Charge of length not less than 2.43 mts set over base coat of cement mortar (1:5) , 12mm thick using screened sand over CC bed already laid or RCC roof slab including neat grey cement slurry of honey like consistency spread @ 3.3 Kg per sqm and jointed neatly with white cement paste mixed with pigment of matching shade to full depth including cost and conveyance of all materials like cement , sand , water , granite slabs etc., to work site and all operational, incidental labour & lift charges, half rounding the edges of treads , polishing charges and all other taxes on all materials, cost of base coat and overheads & contractors profit complete for finished item of work for treads and risers (S.S.701 & special). Treads of 0.30m wide : Ground Floor/ First Floor :

91

-

602420

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Granolithic Concrete flooring 20 mm thick with (1:1:2), using 6mm to 12 mm size hard granite machine crushed metal and screened sand laid over CC bed already laid or RCC roof slab, in alternate panels of size not exceeding 1.50 m x 1.50 m, using glass strips and finishing the top surface to required smoothness and slopes and thread lining including cost of all materials like cement, metal sand and water and overheads & contractors profit complete for finished item of work. (APSS No.701 & 710) Fourth Floor/ Terrace Floor :

29

-

15573

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Flooring with chequered cement concrete heavy duty tiles confirming to IS:13801 using aggregates, cement, pigments of size 300mm x 300mm and thickness 25mm of any shade as approved by Engineer-In-Charge set over base coat of cement mortar (1:6), 12 mm thick using screened sand over CC bed alredy laid or RCC roof slab including neat cement slurry of honey like consistency spread @ 3.3 kgs per sqm and jointed with neat white cement to full depth mixed with pigment of matching shade including cost and conveyance of all materials like cement, sand, water and tiles etc.,and overheads & contractors profit complete for finished item of work Third Floor :

88

-

82104

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Flooring with chequered cement concrete heavy duty tiles confirming to IS:13801 using aggregates, cement, pigments of size 300mm x 300mm and thickness 25mm of any shade as approved by Engineer-In-Charge set over base coat of cement mortar (1:6), 12 mm thick using screened sand over CC bed alredy laid or RCC roof slab including neat cement slurry of honey like consistency spread @ 3.3 kgs per sqm and jointed with neat white cement to full depth mixed with pigment of matching shade including cost and conveyance of all materials like cement, sand, water and tiles etc.,and overheads & contractors profit complete for finished item of work Second Floor :

88

-

78408

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Flooring with chequered cement concrete heavy duty tiles confirming to IS:13801 using aggregates, cement, pigments of size 300mm x 300mm and thickness 25mm of any shade as approved by Engineer-In-Charge set over base coat of cement mortar (1:6), 12 mm thick using screened sand over CC bed alredy laid or RCC roof slab including neat cement slurry of honey like consistency spread @ 3.3 kgs per sqm and jointed with neat white cement to full depth mixed with pigment of matching shade including cost and conveyance of all materials like cement, sand, water and tiles etc.,and overheads & contractors profit complete for finished item of work Ground Floor/ First Floor :

627

-

532323

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Flooring with 16 to 18mm thick high polished granite stone slabs other than black and regular colours (i.e. of shades like paradiso / bala flower / copper silk / laka red / lavender blue) with borders and design as per the pattern approved by the Engineer-in-Charge of length not less than 2.43 mts set over base coat of cement mortar (1:8) , 20mm thick using screened sand over CC bed already laid or RCC roof slab including neat grey cement slurry of honey like consistency spread @ 3.3 Kg per sqm and jointed neatly with white cement paste mixed with pigment of matching shade to full depth including cost and conveyance of all materials like cement , sand , water , granite slabs etc., to work site and all operational, incidental labour & lift charges, polishing charges and all other taxes on all materials, cost of base coat and overheads & contractors profit complete for finished item of work (S.S.701 & special) Third Floor :

30

-

145050

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Flooring with 16 to 18mm thick high polished granite stone slabs other than black and regular colours (i.e. of shades like paradiso / bala flower / copper silk / laka red / lavender blue) with borders and design as per the pattern approved by the Engineer-in-Charge of length not less than 2.43 mts set over base coat of cement mortar (1:8) , 20mm thick using screened sand over CC bed already laid or RCC roof slab including neat grey cement slurry of honey like consistency spread @ 3.3 Kg per sqm and jointed neatly with white cement paste mixed with pigment of matching shade to full depth including cost and conveyance of all materials like cement , sand , water , granite slabs etc., to work site and all operational, incidental labour & lift charges, polishing charges and all other taxes on all materials, cost of base coat and overheads & contractors profit complete for finished item of work (S.S.701 & special) Second Floor :

46

-

218362

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Flooring with 16 to 18mm thick high polished granite stone slabs other than black and regular colours (i.e. of shades like paradiso / bala flower / copper silk / laka red / lavender blue) with borders and design as per the pattern approved by the Engineer-in-Charge of length not less than 2.43 mts set over base coat of cement mortar (1:8) , 20mm thick using screened sand over CC bed already laid or RCC roof slab including neat grey cement slurry of honey like consistency spread @ 3.3 Kg per sqm and jointed neatly with white cement paste mixed with pigment of matching shade to full depth including cost and conveyance of all materials like cement , sand , water , granite slabs etc., to work site and all operational, incidental labour & lift charges, polishing charges and all other taxes on all materials, cost of base coat and overheads & contractors profit complete for finished item of work (S.S.701 & special) Ground Floor/ First Floor :

771

-

3592089

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Flooring with polished shahabad / Tandur stone slabs of 15mm to 18mm thick set over a base coat of CM (1:8) , 12mm thick using screened sand over already laid CC bed / RCC roof slab including neat cement slurry of honey like consistency spread @ 3.3 Kgs per Sqm and jointed with neat cement to full depth including cost and conveyance of all materials like cement, sand, water, flooring stones etc. complete including sales & other taxes on all materials including all labour charges like dressing of flooring stones to the required size, mixing of cement mortar, laying, lift charges , cost of base coat, water charges etc., and overheads & contractors profit complete for finished item of work. (APSS No.703 & 701) Ground Floor/ First Floor :

41

-

33333

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Flooring with Double charged / multi charged stain free full body porcelain vitrified tiles with double layer pigment of size 600 x 600 mm and thickness between 8-10 mm 1st quality conforming to IS:15622 - 2017, IS:13630 (Parts 1 to 15) of any colour and finish in all shades and designs as per the approved flooring pattern as directed by the Engineer-In -Charge, laying tiles using spacers of 2mm thick, set over a base coat of CM (1:8) prop. 12mm thick using screened sand over CC bed already laid or RCC roof slab , including neat cement slurry of honey like consistancy spread @ 3.3 kgs per Sqm. and jointed neately with white cement paste to full depth mixed with pigment of matching shade including cost and conveyance of all materials like cement, sand, water, tiles, white cement etc., to site (excluding cost of C.C. bed) including cost of base coat and all labour charges for mixing of cement mortar, laying tiles to required slope as directed by the Engineer- in-charge etc., and overheads & contractors profit complete for finished item of work. (APSS No.701 & 707). Third Floor :

88

-

120120

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Flooring with Double charged / multi charged stain free full body porcelain vitrified tiles with double layer pigment of size 600 x 600 mm and thickness between 8-10 mm 1st quality conforming to IS:15622 - 2017, IS:13630 (Parts 1 to 15) of any colour and finish in all shades and designs as per the approved flooring pattern as directed by the Engineer-In -Charge, laying tiles using spacers of 2mm thick, set over a base coat of CM (1:8) prop. 12mm thick using screened sand over CC bed already laid or RCC roof slab , including neat cement slurry of honey like consistancy spread @ 3.3 kgs per Sqm. and jointed neately with white cement paste to full depth mixed with pigment of matching shade including cost and conveyance of all materials like cement, sand, water, tiles, white cement etc., to site (excluding cost of C.C. bed) including cost of base coat and all labour charges for mixing of cement mortar, laying tiles to required slope as directed by the Engineer- in-charge etc., and overheads & contractors profit complete for finished item of work. (APSS No.701 & 707). Ground Floor/ First Floor :

44

-

55836

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Flooring with Nano polished /stain free soluble salt porcelain vitrified tiles screen printed of size 600 x 600 mm and thickness between 8-10 mm 1st quality conforming to IS:13711, IS:13712, IS:13630 (Parts 1 to 15) of any colour and finish in all shades and designs as per the approved flooring pattern as directed by the Engineer-In -Charge, laying tiles using spacers of 2mm thick, set over a base coat of CM (1:8) prop. 12mm thick using screened sand over CC bed already laid or RCC roof slab , including neat cement slurry of honey like consistancy spread @ 3.3 kgs per Sqm. and jointed neately with white cement paste to full depth mixed with pigment of matching shade including cost and conveyance of all materials like cement, sand, water, tiles, white cement etc., to site (excluding cost of C.C. bed) including cost of base coat and all labour charges for mixing of cement mortar, laying tiles to required slope as directed by the Engineer- in-charge etc.,and overheads & contractors profit complete for finished item of work. (APSS No.701 & 707). Third Floor :

1605

-

1929210

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Flooring with Nano polished /stain free soluble salt porcelain vitrified tiles screen printed of size 600 x 600 mm and thickness between 8-10 mm 1st quality conforming to IS:13711, IS:13712, IS:13630 (Parts 1 to 15) of any colour and finish in all shades and designs as per the approved flooring pattern as directed by the Engineer-In -Charge, laying tiles using spacers of 2mm thick, set over a base coat of CM (1:8) prop. 12mm thick using screened sand over CC bed already laid or RCC roof slab , including neat cement slurry of honey like consistancy spread @ 3.3 kgs per Sqm. and jointed neately with white cement paste to full depth mixed with pigment of matching shade including cost and conveyance of all materials like cement, sand, water, tiles, white cement etc., to site (excluding cost of C.C. bed) including cost of base coat and all labour charges for mixing of cement mortar, laying tiles to required slope as directed by the Engineer- in-charge etc.,and overheads & contractors profit complete for finished item of work. (APSS No.701 & 707). Second Floor :

3124

-

3605096

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Flooring with Nano polished /stain free soluble salt porcelain vitrified tiles screen printed of size 600 x 600 mm and thickness between 8-10 mm 1st quality conforming to IS:13711, IS:13712, IS:13630 (Parts 1 to 15) of any colour and finish in all shades and designs as per the approved flooring pattern as directed by the Engineer-In -Charge, laying tiles using spacers of 2mm thick, set over a base coat of CM (1:8) prop. 12mm thick using screened sand over CC bed already laid or RCC roof slab , including neat cement slurry of honey like consistancy spread @ 3.3 kgs per Sqm. and jointed neately with white cement paste to full depth mixed with pigment of matching shade including cost and conveyance of all materials like cement, sand, water, tiles, white cement etc., to site (excluding cost of C.C. bed) including cost of base coat and all labour charges for mixing of cement mortar, laying tiles to required slope as directed by the Engineer- in-charge etc.,and overheads & contractors profit complete for finished item of work. (APSS No.701 & 707). Ground Floor/ First Floor :

2750

-

3041500

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Flooring with non-skid full body ceramic floor tiles of size 300mm x 300mm and thickness between 7 - 8mm 1st quality conforming to IS: 13711, IS: 13712, IS: 13630(Part 1 to 15) of any colour and finish in all shades and designs as approved by Engineer-in-charge, set over base coat of cement mortar (1:8), 12mm thick using screened sand over CC bed already laid or RCC roof slab, including neat cement slurry of honey like consistency spread @ 3.3 Kgs per Sqm & jointed neatly with white cement paste to full depth mixed with pigment of matching shade, including cost of all materials like cement, screened sand , water and tiles etc., and overheads & contractors profit complete for finished item of work. (In toilets) (APSS No.701 & 707). Third Floor :

186

-

191952

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Flooring with non-skid full body ceramic floor tiles of size 300mm x 300mm and thickness between 7 - 8mm 1st quality conforming to IS: 13711, IS: 13712, IS: 13630(Part 1 to 15) of any colour and finish in all shades and designs as approved by Engineer-in-charge, set over base coat of cement mortar (1:8), 12mm thick using screened sand over CC bed already laid or RCC roof slab, including neat cement slurry of honey like consistency spread @ 3.3 Kgs per Sqm & jointed neatly with white cement paste to full depth mixed with pigment of matching shade, including cost of all materials like cement, screened sand , water and tiles etc., and overheads & contractors profit complete for finished item of work. (In toilets) (APSS No.701 & 707). Second Floor :

307

-

302088

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Flooring with non-skid full body ceramic floor tiles of size 300mm x 300mm and thickness between 7 - 8mm 1st quality conforming to IS: 13711, IS: 13712, IS: 13630(Part 1 to 15) of any colour and finish in all shades and designs as approved by Engineer-in-charge, set over base coat of cement mortar (1:8), 12mm thick using screened sand over CC bed already laid or RCC roof slab, including neat cement slurry of honey like consistency spread @ 3.3 Kgs per Sqm & jointed neatly with white cement paste to full depth mixed with pigment of matching shade, including cost of all materials like cement, screened sand , water and tiles etc., and overheads & contractors profit complete for finished item of work. (In toilets) (APSS No.701 & 707). Ground Floor/ First Floor :

317

-

296712

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Providing impervious coat to exposed RCC roof slab surfaces of sump, sump side wall,sump bottom slab, in side of septic tank, in sunken slabs etc. to required slopes with CM (1:3) prop. using screened sand 12mm thick mixed with integral cement water proofing liquid confirming to IS: 2645-2003 manufactured by reputed manufacturers as approved by Engineer-in-charge at 1 Kg per one bag of cement, laid over roof slab when it is green, finished smooth with a floating coat of neat cement and thread lining at regular intervals of 45cmx45cm where ever necessary including cost and conveyance of all materials like cement, sand, water proofing compound, water etc., to site, including sales & other taxes on all materials and operational, incidental, and labour charges for mixing mortar, laying, lift charges, rendering smooth and thread lining, curing including rounding off junctions of wall and slab etc., and overheads & contractors profit complete for finished item of work. (APSS No. 901 & 903). Fourth Floo/ Terrace Floor :

223

-

54412

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Providing impervious coat to exposed RCC roof slab surfaces of sump, sump side wall,sump bottom slab, in side of septic tank, in sunken slabs etc. to required slopes with CM (1:3) prop. using screened sand 12mm thick mixed with integral cement water proofing liquid confirming to IS: 2645-2003 manufactured by reputed manufacturers as approved by Engineer-in-charge at 1 Kg per one bag of cement, laid over roof slab when it is green, finished smooth with a floating coat of neat cement and thread lining at regular intervals of 45cmx45cm where ever necessary including cost and conveyance of all materials like cement, sand, water proofing compound, water etc., to site, including sales & other taxes on all materials and operational, incidental, and labour charges for mixing mortar, laying, lift charges, rendering smooth and thread lining, curing including rounding off junctions of wall and slab etc., and overheads & contractors profit complete for finished item of work. (APSS No. 901 & 903). Third Floor :

265

-

61480

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Providing impervious coat to exposed RCC roof slab surfaces of sump, sump side wall,sump bottom slab, in side of septic tank, in sunken slabs etc. to required slopes with CM (1:3) prop. using screened sand 12mm thick mixed with integral cement water proofing liquid confirming to IS: 2645-2003 manufactured by reputed manufacturers as approved by Engineer-in-charge at 1 Kg per one bag of cement, laid over roof slab when it is green, finished smooth with a floating coat of neat cement and thread lining at regular intervals of 45cmx45cm where ever necessary including cost and conveyance of all materials like cement, sand, water proofing compound, water etc., to site, including sales & other taxes on all materials and operational, incidental, and labour charges for mixing mortar, laying, lift charges, rendering smooth and thread lining, curing including rounding off junctions of wall and slab etc., and overheads & contractors profit complete for finished item of work. (APSS No. 901 & 903). Second Floor :

470

-

103870

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Providing impervious coat to exposed RCC roof slab surfaces of sump, sump side wall,sump bottom slab, in side of septic tank, in sunken slabs etc. to required slopes with CM (1:3) prop. using screened sand 12mm thick mixed with integral cement water proofing liquid confirming to IS: 2645-2003 manufactured by reputed manufacturers as approved by Engineer-in-charge at 1 Kg per one bag of cement, laid over roof slab when it is green, finished smooth with a floating coat of neat cement and thread lining at regular intervals of 45cmx45cm where ever necessary including cost and conveyance of all materials like cement, sand, water proofing compound, water etc., to site, including sales & other taxes on all materials and operational, incidental, and labour charges for mixing mortar, laying, lift charges, rendering smooth and thread lining, curing including rounding off junctions of wall and slab etc., and overheads & contractors profit complete for finished item of work. (APSS No. 901 & 903). First Floor :

276

-

57684

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Providing impervious coat to exposed RCC roof slab surfaces to required slopes with CM (1:3) prop. using screened sand 20mm thick (average) mixed with integral cement water proofing liquid confirming to IS: 2645-2003 manufactured by reputed manufacturers as approved by Engineer-in-charge at 1 Kg per one bag of cement, laid over roof slab when it is green, finished smooth with a floating coat of neat cement and thread lining at regular intervals of 45cmx45cm including cost and conveyance of all materials like cement, sand, water proofing compound, water etc., to site, including sales & other taxes on all materials and operational, incidental, and labour charges for mixing mortar, laying, lift charges, rendering smooth and thread lining, curing including rounding off junctions of wall and slab etc., and overheads & contractors profit complete for finished item of work. (APSS No. 901 & 903). Fourth Floor :

4110

-

2848230

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Providing impervious coat to exposed RCC roof slab surfaces to required slopes with CM (1:3) prop. using screened sand 20mm thick (average) mixed with integral cement water proofing liquid confirming to IS: 2645-2003 manufactured by reputed manufacturers as approved by Engineer-in-charge at 1 Kg per one bag of cement, laid over roof slab when it is green, finished smooth with a floating coat of neat cement and thread lining at regular intervals of 45cmx45cm including cost and conveyance of all materials like cement, sand, water proofing compound, water etc., to site, including sales & other taxes on all materials and operational, incidental, and labour charges for mixing mortar, laying, lift charges, rendering smooth and thread lining, curing including rounding off junctions of wall and slab etc., and overheads & contractors profit complete for finished item of work. (APSS No. 901 & 903).Second Floor

730

-

443110

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Providing impervious coat to exposed RCC roof slab surfaces to required slopes with CM (1:3) prop. using screened sand 20mm thick (average) mixed with integral cement water proofing liquid confirming to IS: 2645-2003 manufactured by reputed manufacturers as approved by Engineer-in-charge at 1 Kg per one bag of cement, laid over roof slab when it is green, finished smooth with a floating coat of neat cement and thread lining at regular intervals of 45cmx45cm including cost and conveyance of all materials like cement, sand, water proofing compound, water etc., to site, including sales & other taxes on all materials and operational, incidental, and labour charges for mixing mortar, laying, lift charges, rendering smooth and thread lining, curing including rounding off junctions of wall and slab etc., and overheads & contractors profit complete for finished item of work. (APSS No. 901 & 903). First Floor

63

-

35532

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Plastering 12mm thick single coat in CM(1:5) using screened sand including cost and conveyance of all materials like cement, sand, water etc., to site, including sales & other taxes on all materials, and all operational, incidental charges on materials and including cost of all labour charges for mixing mortar, finishing, curing as directed by Engineer-in-charge etc., and overheads & contractors profit complete for finished item of work.(SS 901,903 & 904) for basement.

494

-

90896

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Plastering 20mm thick single coat in CM(1:5) using screened sand including cost and conveyance of all materials like cement, sand, water etc., to site, including sales & other taxes on all materials, and all operational, incidental charges on materials and including cost of all labour charges for mixing mortar, finishing, curing as directed by Engineer-in-charge etc., and overheads & contractors profit complete for finished item of work .(SS 901,903 & 904)

523

-

153762

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Plastering 12mm thick in two coats using screened sand with base coat of 8mm thick in CM (1:6) and top coat of 4mm thick in CM (1:4) with dubara sponge finishing including cost and conveyance of all materials like cement, sand, water etc., to site, including sales & other taxes exceluding GST on all materials, and all operational, incidental charges on materials and including cost of all labour charges for mixing mortar, finishing, scaffolding, lift charges, curing, including cutting grooves as directed by Engineer-in-charge etc., and overheads & contractors profit complete for finished item of work for external walls. (SS 901,903 & 904). Fourth Floor/ Terrace Floor :

974

-

651606

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Plastering 12mm thick in two coats using screened sand with base coat of 8mm thick in CM (1:6) and top coat of 4mm thick in CM (1:4) with dubara sponge finishing including cost and conveyance of all materials like cement, sand, water etc., to site, including sales & other taxes exceluding GST on all materials, and all operational, incidental charges on materials and including cost of all labour charges for mixing mortar, finishing, scaffolding, lift charges, curing, including cutting grooves as directed by Engineer-in-charge etc., and overheads & contractors profit complete for finished item of work for external walls. (SS 901,903 & 904). Third Floor :

1805

-

1119100

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Plastering 12mm thick in two coats using screened sand with base coat of 8mm thick in CM (1:6) and top coat of 4mm thick in CM (1:4) with dubara sponge finishing including cost and conveyance of all materials like cement, sand, water etc., to site, including sales & other taxes exceluding GST on all materials, and all operational, incidental charges on materials and including cost of all labour charges for mixing mortar, finishing, scaffolding, lift charges, curing, including cutting grooves as directed by Engineer-in-charge etc., and overheads & contractors profit complete for finished item of work for external walls. (SS 901,903 & 904). Second Floor :

1930

-

1100100

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Plastering 12mm thick in two coats using screened sand with base coat of 8mm thick in CM (1:6) and top coat of 4mm thick in CM (1:4) with dubara sponge finishing including cost and conveyance of all materials like cement, sand, water etc., to site, including sales & other taxes exceluding GST on all materials, and all operational, incidental charges on materials and including cost of all labour charges for mixing mortar, finishing, scaffolding, lift charges, curing, including cutting grooves as directed by Engineer-in-charge etc., and overheads & contractors profit complete for finished item of work for external walls. (SS 901,903 & 904). Ground Floor/ First Floor :

2483

-

1293643

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Plastering 12mm thick in two coats using screened sand with base coat of 8mm thick in CM (1:6) and top coat of 4mm thick in CM (1:4) with dubara sponge finishing including cost and conveyance of all materials like cement, sand, water etc., to site, including sales & other taxes exceluding GST on all materials, and all operational, incidental charges on materials and including cost of all labour charges for mixing mortar, finishing, scaffolding, lift charges, curing, including cutting grooves as directed by Engineer-in-charge etc., and overheads & contractors profit complete for finished item of work for internal walls (SS 901,903 & 904). (SS 901,903 & 904). Fourth Floor/ Terrace Floor :

495

-

331155

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Plastering 12mm thick in two coats using screened sand with base coat of 8mm thick in CM (1:6) and top coat of 4mm thick in CM (1:4) with dubara sponge finishing including cost and conveyance of all materials like cement, sand, water etc., to site, including sales & other taxes exceluding GST on all materials, and all operational, incidental charges on materials and including cost of all labour charges for mixing mortar, finishing, scaffolding, lift charges, curing, including cutting grooves as directed by Engineer-in-charge etc., and overheads & contractors profit complete for finished item of work for internal walls (SS 901,903 & 904). (SS 901,903 & 904). Third Floor :

4836

-

2998320

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Plastering 12mm thick in two coats using screened sand with base coat of 8mm thick in CM (1:6) and top coat of 4mm thick in CM (1:4) with dubara sponge finishing including cost and conveyance of all materials like cement, sand, water etc., to site, including sales & other taxes exceluding GST on all materials, and all operational, incidental charges on materials and including cost of all labour charges for mixing mortar, finishing, scaffolding, lift charges, curing, including cutting grooves as directed by Engineer-in-charge etc., and overheads & contractors profit complete for finished item of work for internal walls (SS 901,903 & 904). (SS 901,903 & 904). Second Floor :

3676

-

2095320

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Plastering 12mm thick in two coats using screened sand with base coat of 8mm thick in CM (1:6) and top coat of 4mm thick in CM (1:4) with dubara sponge finishing including cost and conveyance of all materials like cement, sand, water etc., to site, including sales & other taxes exceluding GST on all materials, and all operational, incidental charges on materials and including cost of all labour charges for mixing mortar, finishing, scaffolding, lift charges, curing, including cutting grooves as directed by Engineer-in-charge etc., and overheads & contractors profit complete for finished item of work for internal walls (SS 901,903 & 904). (SS 901,903 & 904). Ground Floor/ First Floor :

7452

-

3882492

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Ornamental ceiling plastering 12mm thick in two coats using screened sand with base coat of 8mm thick in CM (1:6) and top coat of 4mm thick in CM (1:4) with dubara sponge finishing including cost and conveyance of all materials like cement, sand, water etc., to site, including sales & other taxes on all materials, and all operational, incidental charges on materials and including cost of all labour charges for mixing mortar, finishing, scaffolding, lift charges, curing, including cutting grooves as directed by Engineer-in- harge etc., and overheads & contractors profit complete for finished item of work. (SS 901,903 & 904) Fourth Floor/ Terrace Floor :

150

-

105000

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Ornamental ceiling plastering 12mm thick in two coats using screened sand with base coat of 8mm thick in CM (1:6) and top coat of 4mm thick in CM (1:4) with dubara sponge finishing including cost and conveyance of all materials like cement, sand, water etc., to site, including sales & other taxes on all materials, and all operational, incidental charges on materials and including cost of all labour charges for mixing mortar, finishing, scaffolding, lift charges, curing, including cutting grooves as directed by Engineer-in- harge etc., and overheads & contractors profit complete for finished item of work. (SS 901,903 & 904) Third Floor :

1900

-

1225500

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Ornamental ceiling plastering 12mm thick in two coats using screened sand with base coat of 8mm thick in CM (1:6) and top coat of 4mm thick in CM (1:4) with dubara sponge finishing including cost and conveyance of all materials like cement, sand, water etc., to site, including sales & other taxes on all materials, and all operational, incidental charges on materials and including cost of all labour charges for mixing mortar, finishing, scaffolding, lift charges, curing, including cutting grooves as directed by Engineer-in- harge etc., and overheads & contractors profit complete for finished item of work. (SS 901,903 & 904) Second Floor :

3514

-

2073260

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Ornamental ceiling plastering 12mm thick in two coats using screened sand with base coat of 8mm thick in CM (1:6) and top coat of 4mm thick in CM (1:4) with dubara sponge finishing including cost and conveyance of all materials like cement, sand, water etc., to site, including sales & other taxes on all materials, and all operational, incidental charges on materials and including cost of all labour charges for mixing mortar, finishing, scaffolding, lift charges, curing, including cutting grooves as directed by Engineer-in- harge etc., and overheads & contractors profit complete for finished item of work. (SS 901,903 & 904) Ground Floor/ First Floor :

4050

-

2170800

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Providing Mild steel (MS) steel bars (Fe 250 grade as per IS 432) of different diameters including labour charges for straightening, cutting, bending to required sizes and shapes, placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc. ,and overheads & contractors profit complete for finished item of work.(APSS No.126) Third Floor :

1.71

-

160902

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Providing Mild steel (MS) steel bars (Fe 250 grade as per IS 432) of different diameters including labour charges for straightening, cutting, bending to required sizes and shapes, placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc. ,and overheads & contractors profit complete for finished item of work.(APSS No.126)Second Floor :

2.91

-

269341

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Providing Mild steel (MS) steel bars (Fe 250 grade as per IS 432) of different diameters including labour charges for straightening, cutting, bending to required sizes and shapes, placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc. ,and overheads & contractors profit complete for finished item of work.(APSS No.126) Ground Floor/ First Floor :

3.52

-

320387

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Providing Thermo Mechanically Treated (TMT) (Fe -500/500D/550D from Primary producer TATA, SAIL, VSP, JSW &Shyam Steel etc as per IS 1786-2008) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes, placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc. ,and overheads & contractors profit complete for finished item of work. (APSS No.126). Fourth Floor/ Terrace Floor :

20

-

1912660

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Providing Thermo Mechanically Treated (TMT) (Fe -500/500D/550D from Primary producer TATA, SAIL, VSP, JSW &Shyam Steel etc as per IS 1786-2008) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes, placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc. ,and overheads & contractors profit complete for finished item of work. (APSS No.126). Third Floor :

92.5

-

8703788

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Providing Thermo Mechanically Treated (TMT) (Fe -500/500D/550D from Primary producer TATA, SAIL, VSP, JSW &Shyam Steel etc as per IS 1786-2008) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes, placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc. ,and overheads & contractors profit complete for finished item of work. (APSS No.126).Second Floor :

142.1

-

13152350

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Providing Thermo Mechanically Treated (TMT) (Fe -500/500D/550D from Primary producer TATA, SAIL, VSP, JSW &Shyam Steel etc as per IS 1786-2008) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes, placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc. ,and overheads & contractors profit complete for finished item of work. (APSS No.126). Ground Floor/ First Floor :

340.73

-

31012904

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Reinforced cement concrete (1:5:10) proportion (Cement: fine aggregates: coarse aggregate) using 40mm size (SS5) hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand), coarse aggregate, water etc., to site including centering using Casurina Ballies , Bamboos , Wooden Reapers , Runners , Wood Posts , Wall Plates etc., shuttering, machine mixing, laying concrete, lifting concrete manually , curing etc., and overheads & contractors profit complete as per drawings but excluding cost of steel and it's fabrication charges for finished item of work (APSS NO. 402 & 403) for Dummy columns. Fourth Floor/ Terrace Floor :

23

-

298678

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Reinforced cement concrete (1:5:10) proportion (Cement: fine aggregates: coarse aggregate) using 40mm size (SS5) hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand), coarse aggregate, water etc., to site including centering using Casurina Ballies , Bamboos , Wooden Reapers , Runners , Wood Posts , Wall Plates etc., shuttering, machine mixing, laying concrete, lifting concrete manually , curing etc., and overheads & contractors profit complete as per drawings but excluding cost of steel and it's fabrication charges for finished item of work (APSS NO. 402 & 403) for Dummy columns. Third Floor/ Terrace Floor :

19

-

234498

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Reinforced cement concrete (1:5:10) proportion (Cement: fine aggregates: coarse aggregate) using 40mm size (SS5) hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand), coarse aggregate, water etc., to site including centering using Casurina Ballies , Bamboos , Wooden Reapers , Runners , Wood Posts , Wall Plates etc., shuttering, machine mixing, laying concrete, lifting concrete manually , curing etc., and overheads & contractors profit complete as per drawings but excluding cost of steel and it's fabrication charges for finished item of work (APSS NO. 402 & 403) for Dummy columns. Second Floor/ Terrace Floor :

4

-

46792

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Filling with light weight concrete in Cement Concrete (1:5:10) proportion using brick jelly for low roofs including cost and conveyance of all materials like cement, sand, brick bats etc., to site including cost of all labour charges for laying concrete, ramming, curing, overheads & contractors profit etc., complete for finished item of work. (APSS. No. 402). Third Floor :

61

-

340502

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Filling with light weight concrete in Cement Concrete (1:5:10) proportion using brick jelly for low roofs including cost and conveyance of all materials like cement, sand, brick bats etc., to site including cost of all labour charges for laying concrete, ramming, curing, overheads & contractors profit etc., complete for finished item of work. (APSS. No. 402). Second Floor :

97

-

531075

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Plain Cement Concrete (1:3:6) nominal mix using 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate(sand), coarse aggregate, water etc. to site, including sales & other taxes on all materials and including all charges for mixing, laying concrete in position, curing etc., & lift charges , and overheads & contractors profit for Bed Blocks & Hold Fasts for finished item of work. (APSS No. 402) Fourth Floor/ Terrace Floor :

1

-

6838

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Plain Cement Concrete (1:3:6) nominal mix using 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate(sand), coarse aggregate, water etc. to site, including sales & other taxes on all materials and including all charges for mixing, laying concrete in position, curing etc., & lift charges , and overheads & contractors profit for Bed Blocks & Hold Fasts for finished item of work. (APSS No. 402) Third Floor :

10

-

66780

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Plain Cement Concrete (1:3:6) nominal mix using 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate(sand), coarse aggregate, water etc. to site, including sales & other taxes on all materials and including all charges for mixing, laying concrete in position, curing etc., & lift charges , and overheads & contractors profit for Bed Blocks & Hold Fasts for finished item of work. (APSS No. 402) Second Floor :

20

-

130360

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Plain Cement Concrete (1:3:6) nominal mix using 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate(sand), coarse aggregate, water etc. to site, including sales & other taxes on all materials and including all charges for mixing, laying concrete in position, curing etc., & lift charges , and overheads & contractors profit for Bed Blocks & Hold Fasts for finished item of work. (APSS No. 402) Ground Floor/ First Floor :

25.4

-

161493

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Plain Cement Concrete M 20 nominal mix using WEIGH BATCHER / MIXER, 20mm size hard granite machine crushed graded metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry, using a minimum quantity of 300 kgs. of cement per 1 cum of concrete including cost and conveyance of all materials like cement, fine aggregate (Sand), coarse aggregate, water etc., to site including steel centering, shuttering, machine mixing, lift charges, laying concrete,vibrating, curing, overheads & contrctors profit etc., complete for finished item of work for coping on top of compound wall (APSS No. 402 & 403). Ground Floor/ First Floor :

2

-

12858

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Plain Cement Concrete M 20 design mix using Concrete Batching Plant, 20mm size hard granite machine crushed graded metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry, using a minimum quantity of 330 kgs. of cement per 1 cum of concrete including cost and conveyance of all materials like cement, fine aggregate (Sand), coarse aggregate, water etc., to site including steel centering, shuttering, machine mixing, lift charges, laying concrete,vibrating, curing, overheads & contrctors profit etc., complete for finished item of work (APSS No. 402 & 403) for steps. Third Floor :

6

-

50190

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Plain Cement Concrete M 20 design mix using Concrete Batching Plant, 20mm size hard granite machine crushed graded metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry, using a minimum quantity of 330 kgs. of cement per 1 cum of concrete including cost and conveyance of all materials like cement, fine aggregate (Sand), coarse aggregate, water etc., to site including steel centering, shuttering, machine mixing, lift charges, laying concrete,vibrating, curing, overheads & contrctors profit etc., complete for finished item of work (APSS No. 402 & 403) for steps. Second Floor :

6

-

48468

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Plain Cement Concrete M 20 design mix using Concrete Batching Plant, 20mm size hard granite machine crushed graded metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry, using a minimum quantity of 330 kgs. of cement per 1 cum of concrete including cost and conveyance of all materials like cement, fine aggregate (Sand), coarse aggregate, water etc., to site including steel centering, shuttering, machine mixing, lift charges, laying concrete,vibrating, curing, overheads & contrctors profit etc., complete for finished item of work (APSS No. 402 & 403) for steps. Ground Floor/ First Floor :

6

-

46746

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Reinforced Masonry for partition walls (100 mm thick) in CM (1:4) prop. (Cement : Screened sand) using fly ash cement / lime solid blocks of size 290mm x 100mm x 140mm having minimum compressive strength of 50 Kg/Sq.cmand placing 2 Nos. of 6mm M.S plain rods in every third layer with free ends of the reinforcement pegged into mortar joints of main brick walls where applicable including cost and conveyance of all materials like cement, steel, sand, bricks, water etc., to site, including sales & other taxes on all materials, all operational, incidental charges such as labour charges for mixing cement mortar, scaffolding charges, constructing masonry, lift charges, curing, etc., and overheads & contractors profit but excluding cost of steel and its fabrication charges complete for finished item of work. (APSS No. of 509) Third Floor :

426

-

453690

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Reinforced Masonry for partition walls (100 mm thick) in CM (1:4) prop. (Cement : Screened sand) using fly ash cement / lime solid blocks of size 290mm x 100mm x 140mm having minimum compressive strength of 50 Kg/Sq.cmand placing 2 Nos. of 6mm M.S plain rods in every third layer with free ends of the reinforcement pegged into mortar joints of main brick walls where applicable including cost and conveyance of all materials like cement, steel, sand, bricks, water etc., to site, including sales & other taxes on all materials, all operational, incidental charges such as labour charges for mixing cement mortar, scaffolding charges, constructing masonry, lift charges, curing, etc., and overheads & contractors profit but excluding cost of steel and its fabrication charges complete for finished item of work. (APSS No. of 509) Second Floor :

492

-

481176

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Reinforced Masonry for partition walls (100 mm thick) in CM (1:4) prop. (Cement : Screened sand) using fly ash cement / lime solid blocks of size 290mm x 100mm x 140mm having minimum compressive strength of 50 Kg/Sq.cmand placing 2 Nos. of 6mm M.S plain rods in every third layer with free ends of the reinforcement pegged into mortar joints of main brick walls where applicable including cost and conveyance of all materials like cement, steel, sand, bricks, water etc., to site, including sales & other taxes on all materials, all operational, incidental charges such as labour charges for mixing cement mortar, scaffolding charges, constructing masonry, lift charges, curing, etc., and overheads & contractors profit but excluding cost of steel and its fabrication charges complete for finished item of work. (APSS No. of 509) Ground Floor/ First Floor :

941

-

839372

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Masonry work in CM(1:6) prop (Cement : Screened sand) in superstructure with fly ash cement / lime solid blocks of size 290mm x 225mm x 140mm from approved source having minimum crushing strength of 50 Kg/Sqcm. including cost and conveyance of all materials like cement, sand, bricks, water etc., to site, including sales & other taxes on all materials and such as labour charges, like mixing cement mortar, scaffolding charges, constructing masonry, lift charges, curing, overheads and contrctor profit etc., complete for finished item of work. (APSS No. 501 & 504). Fourth Floor/ Terrace Floor :

145

-

1417955

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Masonry work in CM(1:6) prop (Cement : Screened sand) in superstructure with fly ash cement / lime solid blocks of size 290mm x 225mm x 140mm from approved source having minimum crushing strength of 50 Kg/Sqcm. including cost and conveyance of all materials like cement, sand, bricks, water etc., to site, including sales & other taxes on all materials and such as labour charges, like mixing cement mortar, scaffolding charges, constructing masonry, lift charges, curing, overheads and contrctor profit etc., complete for finished item of work. (APSS No. 501 & 504). Third Floor :

572.8

-

5285226

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Masonry work in CM(1:6) prop (Cement : Screened sand) in superstructure with fly ash cement / lime solid blocks of size 290mm x 225mm x 140mm from approved source having minimum crushing strength of 50 Kg/Sqcm. including cost and conveyance of all materials like cement, sand, bricks, water etc., to site, including sales & other taxes on all materials and such as labour charges, like mixing cement mortar, scaffolding charges, constructing masonry, lift charges, curing, overheads and contrctor profit etc., complete for finished item of work. (APSS No. 501 & 504). Second Floor :

730.8

-

6340421

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Masonry work in CM(1:6) prop (Cement : Screened sand) in superstructure with fly ash cement / lime solid blocks of size 290mm x 225mm x 140mm from approved source having minimum crushing strength of 50 Kg/Sqcm. including cost and conveyance of all materials like cement, sand, bricks, water etc., to site, including sales & other taxes on all materials and such as labour charges, like mixing cement mortar, scaffolding charges, constructing masonry, lift charges, curing, overheads and contrctor profit etc., complete for finished item of work. (APSS No. 501 & 504). Ground Floor/ First Floor :

733.5

-

5959688

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Masonry work in CM(1:6) prop (Cement : Screened sand) in superstructure with fly ash cement / lime solid blocks of size 290mm x 225mm x 140mm from approved source having minimum crushing strength of 50 Kg/Sqcm. including cost and conveyance of all materials like cement, sand, bricks, water etc., to site, including sales & other taxes on all materials and such as labour charges, like mixing cement mortar, scaffolding charges, constructing masonry, lift charges, curing, overheads and contrctor profit etc., complete for finished item of work. (APSS No. 501 & 504). Basement

8

-

59960

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Reinforced Cement Concrete M 20 design mix using 12mm size hard granite machine crushed graded metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry, using a minimum quantity of 350 kgs. of cement per 1 cum of concrete using WEIGH BATCHER / MIXER including cost and conveyance of all materials like cement, fine aggregate (Sand), coarse aggregate, water etc., to site including steel centering, shuttering, labour charges such as weigh batching, machine mixing, laying concrete, lift charges, curing etc., and overheads & contractors profit complete for finished item of work (APSS No. 402 & 403) for Platforms & Shelves 25mm thick shelves Third Floor :

76

-

24472

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Reinforced Cement Concrete M 20 design mix using 12mm size hard granite machine crushed graded metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry, using a minimum quantity of 350 kgs. of cement per 1 cum of concrete using WEIGH BATCHER / MIXER including cost and conveyance of all materials like cement, fine aggregate (Sand), coarse aggregate, water etc., to site including steel centering, shuttering, labour charges such as weigh batching, machine mixing, laying concrete, lift charges, curing etc., and overheads & contractors profit complete for finished item of work (APSS No. 402 & 403) for Platforms & Shelves 25mm thick shelvesSecond Floor :

76

-

23484

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Reinforced Cement Concrete M 20 design mix using 12mm size hard granite machine crushed graded metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry, using a minimum quantity of 350 kgs. of cement per 1 cum of concrete using WEIGH BATCHER / MIXER including cost and conveyance of all materials like cement, fine aggregate (Sand), coarse aggregate, water etc., to site including steel centering, shuttering, labour charges such as weigh batching, machine mixing, laying concrete, lift charges, curing etc., and overheads & contractors profit complete for finished item of work (APSS No. 402 & 403) for Platforms & Shelves 25mm thick shelves Ground Floor/ First Floor :

108

-

32076

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Reinforced Cement Concrete M 20 design mix using 12mm size hard granite machine crushed graded metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry, using a minimum quantity of 350 kgs. of cement per 1 cum of concrete using WEIGH BATCHER / MIXER including cost and conveyance of all materials like cement, fine aggregate (Sand), coarse aggregate, water etc., to site including steel centering, shuttering, labour charges such as weigh batching, machine mixing, laying concrete, lift charges, curing etc., and overheads & contractors profit complete for finished item of work (APSS No. 402 & 403) for Platforms & Shelves 50mm thick Platforms & Lofts Third Floor :

74

-

47656

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Reinforced Cement Concrete M 20 design mix using 12mm size hard granite machine crushed graded metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry, using a minimum quantity of 350 kgs. of cement per 1 cum of concrete using WEIGH BATCHER / MIXER including cost and conveyance of all materials like cement, fine aggregate (Sand), coarse aggregate, water etc., to site including steel centering, shuttering, labour charges such as weigh batching, machine mixing, laying concrete, lift charges, curing etc., and overheads & contractors profit complete for finished item of work (APSS No. 402 & 403) for Platforms & Shelves 50mm thick Platforms & Lofts Second Floor :

74

-

45806

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Reinforced Cement Concrete M 20 design mix using 12mm size hard granite machine crushed graded metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry, using a minimum quantity of 350 kgs. of cement per 1 cum of concrete using WEIGH BATCHER / MIXER including cost and conveyance of all materials like cement, fine aggregate (Sand), coarse aggregate, water etc., to site including steel centering, shuttering, labour charges such as weigh batching, machine mixing, laying concrete, lift charges, curing etc., and overheads & contractors profit complete for finished item of work (APSS No. 402 & 403) for Platforms & Shelves 50mm thick Platforms & Lofts Ground Floor/ First Floor :

126

-

74718

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Reinforced Cement Concrete M 20 design mix using 12mm size hard granite machine crushed graded metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry, using a minimum quantity of 350 kgs. of cement per 1 cum of concrete using WEIGH BATCHER / MIXER including cost and conveyance of all materials like cement, fine aggregate (Sand), coarse aggregate, water etc., to site including steel centering, shuttering, labour charges such as weigh batching, machine mixing, laying concrete, lift charges, curing etc., and overheads & contractors profit complete for finished item of work (APSS No. 402 & 403) for Platforms & Shelves 75mm thick Platforms & Lofts Third Floor :

107

-

87954

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Reinforced Cement Concrete M 20 design mix using 12mm size hard granite machine crushed graded metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry, using a minimum quantity of 350 kgs. of cement per 1 cum of concrete using WEIGH BATCHER / MIXER including cost and conveyance of all materials like cement, fine aggregate (Sand), coarse aggregate, water etc., to site including steel centering, shuttering, labour charges such as weigh batching, machine mixing, laying concrete, lift charges, curing etc., and overheads & contractors profit complete for finished item of work (APSS No. 402 & 403) for Platforms & Shelves 75mm thick Platforms & Lofts Second Floor :

107

-

85279

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Reinforced Cement Concrete M 20 design mix using 12mm size hard granite machine crushed graded metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry, using a minimum quantity of 350 kgs. of cement per 1 cum of concrete using WEIGH BATCHER / MIXER including cost and conveyance of all materials like cement, fine aggregate (Sand), coarse aggregate, water etc., to site including steel centering, shuttering, labour charges such as weigh batching, machine mixing, laying concrete, lift charges, curing etc., and overheads & contractors profit complete for finished item of work (APSS No. 402 & 403) for Platforms & Shelves 75mm thick Platforms & Lofts Ground Floor/ First Floor :

162

-

125064

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Reinforced Cement Concrete M 20 design mix using 12mm size hard granite machine crushed graded metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry, using a minimum quantity of 350 kgs. of cement per 1 cum of concrete using Concrete Batching Plant including cost and conveyance of all materials like cement, fine aggregate (Sand), coarse aggregate, water etc., to site including steel centering, shuttering, machine mixing, laying concrete, lift charges, curing etc., and overheads & contractors profit complete for finished item of work (APSS No. 402 & 403) for sill slabs. Third Floor :

3

-

26877

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Reinforced Cement Concrete M 20 design mix using 12mm size hard granite machine crushed graded metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry, using a minimum quantity of 350 kgs. of cement per 1 cum of concrete using Concrete Batching Plant including cost and conveyance of all materials like cement, fine aggregate (Sand), coarse aggregate, water etc., to site including steel centering, shuttering, machine mixing, laying concrete, lift charges, curing etc., and overheads & contractors profit complete for finished item of work (APSS No. 402 & 403) for sill slabs. Second Floor :

6

-

51720

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Reinforced Cement Concrete M 20 design mix using 12mm size hard granite machine crushed graded metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry, using a minimum quantity of 350 kgs. of cement per 1 cum of concrete using Concrete Batching Plant including cost and conveyance of all materials like cement, fine aggregate (Sand), coarse aggregate, water etc., to site including steel centering, shuttering, machine mixing, laying concrete, lift charges, curing etc., and overheads & contractors profit complete for finished item of work (APSS No. 402 & 403) for sill slabs. Ground Floor/ First Floor :

5.8

-

48024

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using Concrete Batching Plant with 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including sales & other taxes on all materials , centering using Casurina Ballies , Bamboos , Wooden Reapers , Runners , Wood Posts , Wall Plates etc., for 60cm wide sun-shades 7.5cm thick at fixed end and 5cm thick at free end with an average thickness of 6.25cm including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete manually, laying concrete, curing, overheads & contractors profit complete etc., but excluding cost of steel and its fabrication charges for finished item of work. (APSS No. 402, 403 & 903) Third Floor :

182

-

116298

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using Concrete Batching Plant with 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including sales & other taxes on all materials , centering using Casurina Ballies , Bamboos , Wooden Reapers , Runners , Wood Posts , Wall Plates etc., for 60cm wide sun-shades 7.5cm thick at fixed end and 5cm thick at free end with an average thickness of 6.25cm including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete manually, laying concrete, curing, overheads & contractors profit complete etc., but excluding cost of steel and its fabrication charges for finished item of work. (APSS No. 402, 403 & 903) Second Floor :

398

-

243178

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using Concrete Batching Plant with 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including sales & other taxes on all materials , centering using Casurina Ballies , Bamboos , Wooden Reapers , Runners , Wood Posts , Wall Plates etc., for 60cm wide sun-shades 7.5cm thick at fixed end and 5cm thick at free end with an average thickness of 6.25cm including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete manually, laying concrete, curing, overheads & contractors profit complete etc., but excluding cost of steel and its fabrication charges for finished item of work. (APSS No. 402, 403 & 903) Ground Floor/ First Floor :

363

-

211629

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Ornamental borders by providing 20mm thick raised bands of 230 mm wide in plain cement mortor bands in CM(1:4) 360 Kg ,including cost and conveyence of all materials, labour charges and scaffolding s etc., curing, overheads & contractors profit etc., complete for finished item of work. for all Floors

2468

-

345520

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using Concrete Batching Plant with 20mm size graded machine crushed hard granite metal(coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and sales & other taxes on all materials, centering using Steel scaffolding pipes, jack props, Steel centering Plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete mechanically, laying concrete, curing, overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402). Roof Slabs upto un supported height of3.66m Roof Slabs 150mm thickupto un supported height of 7.32 m : Ground Floor/ First Floor :

390

-

950040

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using Concrete Batching Plant with 20mm size graded machine crushed hard granite metal(coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and sales & other taxes on all materials, centering using Steel scaffolding pipes, jack props, Steel centering Plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete mechanically, laying concrete, curing, overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402). Roof Slabs upto un supported height of3.66m Roof Slabs 175mm thick : upto un supported height of 4.27m Third Floor :

1128

-

2515440

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using Concrete Batching Plant with 20mm size graded machine crushed hard granite metal(coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and sales & other taxes on all materials, centering using Steel scaffolding pipes, jack props, Steel centering Plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete mechanically, laying concrete, curing, overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402). Roof Slabs upto un supported height of3.66m Roof Slabs 150mm thick : upto un supported height of 4.27m Third Floor :

131

-

263572

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using Concrete Batching Plant with 20mm size graded machine crushed hard granite metal(coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and sales & other taxes on all materials, centering using Steel scaffolding pipes, jack props, Steel centering Plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete mechanically, laying concrete, curing, overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402). Roof Slabs upto un supported height of3.66m Roof Slabs 125mm thick : upto un supported height of 4.27m Third Floor :

546

-

993174

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using Concrete Batching Plant with 20mm size graded machine crushed hard granite metal(coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and sales & other taxes on all materials, centering using Steel scaffolding pipes, jack props, Steel centering Plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete mechanically, laying concrete, curing, overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402). Roof Slabs upto un supported height of3.66m Roof Slabs 175mm thick : upto un supported height of 3.66m Second Floor :

2176

-

4493440

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using Concrete Batching Plant with 20mm size graded machine crushed hard granite metal(coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and sales & other taxes on all materials, centering using Steel scaffolding pipes, jack props, Steel centering Plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete mechanically, laying concrete, curing, overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402). Roof Slabs upto un supported height of3.66m Roof Slabs 175mm thick : upto un supported height of 3.66m Ground Floor/ First Floor :

2211

-

4391046

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using Concrete Batching Plant with 20mm size graded machine crushed hard granite metal(coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and sales & other taxes on all materials, centering using Steel scaffolding pipes, jack props, Steel centering Plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete mechanically, laying concrete, curing, overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402). Roof Slabs upto un supported height of3.66m Roof Slabs 150mm thick : upto un supported height of 3.66m Fourth Floor/ Terrace Floor :

51

-

98430

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using Concrete Batching Plant with 20mm size graded machine crushed hard granite metal(coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and sales & other taxes on all materials, centering using Steel scaffolding pipes, jack props, Steel centering Plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete mechanically, laying concrete, curing, overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402). Roof Slabs upto un supported height of3.66m Roof Slabs 150mm thick : upto un supported height of 3.66m Second Floor :

131

-

242612

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using Concrete Batching Plant with 20mm size graded machine crushed hard granite metal(coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and sales & other taxes on all materials, centering using Steel scaffolding pipes, jack props, Steel centering Plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete mechanically, laying concrete, curing, overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402). Roof Slabs upto un supported height of3.66m Roof Slabs 150mm thick : upto un supported height of 3.66m Ground Floor/ First Floor :

307

-

546460

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using Concrete Batching Plant with 20mm size graded machine crushed hard granite metal(coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and sales & other taxes on all materials, centering using Steel scaffolding pipes, jack props, Steel centering Plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete mechanically, laying concrete, curing, overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402). Roof Slabs upto un supported height of3.66m Roof Slabs 125mm thick : upto un supported height of 3.66m Fourth Floor/ Terrace Floor :

117

-

203112

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using Concrete Batching Plant with 20mm size graded machine crushed hard granite metal(coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and sales & other taxes on all materials, centering using Steel scaffolding pipes, jack props, Steel centering Plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete mechanically, laying concrete, curing, overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402). Roof Slabs upto un supported height of3.66m Roof Slabs 125mm thick : upto un supported height of 3.66m Third Floor :

72

-

122184

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using Concrete Batching Plant with 20mm size graded machine crushed hard granite metal(coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and sales & other taxes on all materials, centering using Steel scaffolding pipes, jack props, Steel centering Plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete mechanically, laying concrete, curing, overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402). Roof Slabs upto un supported height of3.66m Roof Slabs 125mm thick : upto un supported height of 3.66m Second Floor :

1109

-

1839831

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using Concrete Batching Plant with 20mm size graded machine crushed hard granite metal(coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and sales & other taxes on all materials, centering using Steel scaffolding pipes, jack props, Steel centering Plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete mechanically, laying concrete, curing, overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402). Roof Slabs upto un supported height of3.66m Roof Slabs 125mm thick : upto un supported height of 3.66m Ground Floor/ First Floor :

1403

-

2234979

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using Concrete Batching Plant with 20mm size graded machine crushed hard granite metal(coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and sales & other taxes on all materials, centering using Steel scaffolding pipes, jack props, Steel centering Plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete mechanically, laying concrete, curing, overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402). Roof Beams Roof beams upto un supported height of 7.32 m : Ground Floor/ First Floor : (Doulbe Height)

17

-

328355

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using Concrete Batching Plant with 20mm size graded machine crushed hard granite metal(coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and sales & other taxes on all materials, centering using Steel scaffolding pipes, jack props, Steel centering Plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete mechanically, laying concrete, curing, overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402). Roof Beams Roof Beams upto un supported height of 4.27 m Third Floor :

117

-

1783548

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using Concrete Batching Plant with 20mm size graded machine crushed hard granite metal(coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and sales & other taxes on all materials, centering using Steel scaffolding pipes, jack props, Steel centering Plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete mechanically, laying concrete, curing, overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402). Roof Beams Roof Beams upto un supported height of 3.66 m Fourth Floor/ Terrace Floor :

10

-

145110

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using Concrete Batching Plant with 20mm size graded machine crushed hard granite metal(coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and sales & other taxes on all materials, centering using Steel scaffolding pipes, jack props, Steel centering Plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete mechanically, laying concrete, curing, overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402). Roof Beams Roof Beams upto un supported height of 3.66 m Third Floor :

13.8

-

195601

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using Concrete Batching Plant with 20mm size graded machine crushed hard granite metal(coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and sales & other taxes on all materials, centering using Steel scaffolding pipes, jack props, Steel centering Plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete mechanically, laying concrete, curing, overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402). Roof Beams Roof Beams upto un supported height of 3.66 m Second Floor :

197.8

-

2737156

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using Concrete Batching Plant with 20mm size graded machine crushed hard granite metal(coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and sales & other taxes on all materials, centering using Steel scaffolding pipes, jack props, Steel centering Plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete mechanically, laying concrete, curing, overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402). Roof Beams Roof Beams upto un supported height of 3.66 m Ground Floor/ First Floor :

219.2

-

2910757

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using Concrete Batching Plant with 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and sales & other taxes on all materials, centering using Casurina Ballies, Bamboos, Wooden Reapers, Runners, Wood Posts, Steel Plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete Mechanically, laying concrete, curing , overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402) 230mm thick Retaining wall Ground Floor/ First Floor :

39

-

148161

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using Concrete Batching Plant with 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and sales & other taxes on all materials, centering using Casurina Ballies, Bamboos, Wooden Reapers, Runners, Wood Posts, Steel Plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete Mechanically, laying concrete, curing , overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402) 200mm Thick Sump Side Walls First Floor

188

-

653973

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using Concrete Batching Plant with 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and sales & other taxes on all materials, centering using Casurina Ballies, Bamboos, Wooden Reapers, Runners, Wood Posts, Steel Plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete Mechanically, laying concrete, curing , overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402) 150mm thick Watertank Side wall Fourth Floor/ Terrace Floor :

61

-

193126

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using Concrete Batching Plant with 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and sales & other taxes on all materials, centering using Casurina Ballies, Bamboos, Wooden Reapers, Runners, Wood Posts, Steel Plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete manually, laying concrete, curing , overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402). Lintels Fourth Floor/ Terrace Floor :

1.1

-

17146

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using Concrete Batching Plant with 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and sales & other taxes on all materials, centering using Casurina Ballies, Bamboos, Wooden Reapers, Runners, Wood Posts, Steel Plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete manually, laying concrete, curing , overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402). Lintels Third Floor :

14

-

209454

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using Concrete Batching Plant with 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and sales & other taxes on all materials, centering using Casurina Ballies, Bamboos, Wooden Reapers, Runners, Wood Posts, Steel Plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete manually, laying concrete, curing , overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402). Lintels Second Floor :

26

-

372710

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using Concrete Batching Plant with 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and sales & other taxes on all materials, centering using Casurina Ballies, Bamboos, Wooden Reapers, Runners, Wood Posts, Steel Plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete manually, laying concrete, curing , overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402). LintelsGround Floor/ First Floor :

32.5

-

445543

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using Concrete Batching Plant with 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and sales & other taxes on all materials, centering using Steel scaffolding pipes, jack props, Steel centering Plates etc. including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete mechanically, laying concrete, curing , overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402) Columns - un supported height up to 7.32 m Ground Floor/ First Floor :

41.5

-

840749

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using Concrete Batching Plant with 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and sales & other taxes on all materials, centering using Steel scaffolding pipes, jack props, Steel centering Plates etc. including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete mechanically, laying concrete, curing , overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402) Columns : un supported height up to 4.27 m Third Floor :

93

-

1652424

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using Concrete Batching Plant with 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and sales & other taxes on all materials, centering using Steel scaffolding pipes, jack props, Steel centering Plates etc. including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete mechanically, laying concrete, curing , overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402) Columns : un supported height up to 3.66 m Fourth Floor/ Terrace Floor :

29

-

505876

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using Concrete Batching Plant with 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and sales & other taxes on all materials, centering using Steel scaffolding pipes, jack props, Steel centering Plates etc. including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete mechanically, laying concrete, curing , overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402) Columns : un supported height up to 3.66 m Third Floor :

5

-

84740

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using Concrete Batching Plant with 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and sales & other taxes on all materials, centering using Steel scaffolding pipes, jack props, Steel centering Plates etc. including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete mechanically, laying concrete, curing , overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402) Columns : un supported height up to 3.66 m Second Floor :

156

-

2566668

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using Concrete Batching Plant with 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and sales & other taxes on all materials, centering using Steel scaffolding pipes, jack props, Steel centering Plates etc. including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete mechanically, laying concrete, curing , overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402) Columns : un supported height up to 3.66 m Ground Floor/ First Floor :

303.99

-

4514859

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using batching and mixing plant of 15 cum per hour capacity with 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and sales & other taxes on all materials , centering using Steel scaffolding pipes , jack props , wallers , Foot plates , brackets , steel centering plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, laying concrete, curing etc., and overheads & contractors profit complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402). 200mm thick Bottom Slab

95

-

216885

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using batching and mixing plant of 15 cum per hour capacity with 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and sales & other taxes on all materials , centering using Steel scaffolding pipes , jack props , wallers , Foot plates , brackets , steel centering plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, laying concrete, curing etc., and overheads & contractors profit complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402). Haunch Concrete

2

-

20024

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using batching and mixing plant of 15 cum per hour capacity with 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and sales & other taxes on all materials , centering using Steel scaffolding pipes , jack props , wallers , Foot plates , brackets , steel centering plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, laying concrete, curing etc., and overheads & contractors profit complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402). Plinth Beams :

173.1

-

2473599

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using batching and mixing plant of 15 cum per hour capacity with 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and sales & other taxes on all materials , centering using Steel scaffolding pipes , jack props , wallers , Foot plates , brackets , steel centering plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, laying concrete, curing etc., and overheads & contractors profit complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402). Column Pedestals :

133.6

-

1613754

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using batching and mixing plant of 15 cum per hour capacity with 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and sales & other taxes on all materials , centering using Steel scaffolding pipes , jack props , wallers , Foot plates , brackets , steel centering plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, laying concrete, curing etc., and overheads & contractors profit complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402). Footings :

945.1

-

10790207

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Vibrated Plain Cement Concrete (1:3:6) nominal mix using 40mm size machine crushed hard granite metal and 20mm graded machine crushed hard granite metal (coarse aggregate) in (2:1) ratio from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand), coarse aggregate, water etc. to site, sales & other taxes except GST on all materials, all charges for mixing, laying concrete in position, vibrating, curing, centering charges, overheads & contractors profit etc.,for finished item of work for footings and basement.

333

-

2201463

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Conveyance of un-useful excavated earth to a distance of 5 KM for disposal including hire charges of T & P, labour charges etc., and overheads & contractors profit complete for finished item of work.

388

-

44232

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Filling with carted gravel by manual means in trenches, sides of foundations and basement with initial lead in layers not exceeding 15 cm thick, consolidating each deposited layer by watering and ramming including cost and conveyance of water to work site and all operational, incidental, labour charges, hire charges of T & P etc., and overheads & contractors profit complete for fnished item of work. (APSS NO. 309 & 310)

3337

-

1751925

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Filling with useful available excavated earth by manual means (excluding rock) in trenches, sides of foundations and basement with initial lead in layers not exceeding 15 cm thick, consolidating each deposited layer by watering and ramming including cost and conveyance of water to work site and all operational, incidental, labour charges, hire charges of T & P etc., and overheads & contractors profit complete for finished item of work. (APSS NO. 309 & 310)

2721

-

568689

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Plain Cement Concrete (1:5:10) (cement: fine aggregate: Coarse aggregate) for foundations and under flooring bed using coarse aggregate 40mm size hard , machine crushed granite from approved quarry including cost and conveyance of all materials like cement, sand, coarse aggregate, water etc. to site, sales & other taxes on all materials and including all charges for machine mixing, laying concrete in foundations and under flooring bed, ramming in 15 cm layers finishing top surface to the required level curing etc.,and overheads & contractors profit complete for finished item of work. (APSS No. 402)

519.2

-

2615210

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Plain Cement Concrete (1:4:8) (cement: fine aggregate: Coarse aggregate) for foundations and under flooring bed using coarse aggregate 40mm size hard , machine crushed granite from approved quarry including cost and conveyance of all materials like cement, sand, coarse aggregate, water etc. to site, including sales & other taxes on all materials and including all charges for machine mixing, laying concrete in foundations and under flooring bed, ramming in 15 cm layers finishing top surface to the required level curing etc., and overheads & contractors profit complete for finished item of work. (APSS No. 402)

327.1

-

1713677

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Plain Cement Concrete M 20 design mix using Concrete Batching Plant, 20mm size hard granite machine crushed graded metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry, using a minimum quantity of 330 kgs. of cement per 1 cum of concrete including cost and conveyance of all materials like cement, fine aggregate (Sand), coarse aggregate, water etc., to site including steel centering, shuttering, machine mixing, lift charges, laying concrete,vibrating, curing, overheads & contrctors profit etc., complete for finished item of work (APSS No. 402 & 403) for foundations on sheet rock.

117

-

839475

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Grouting the holes with neat cement slurry excluding cost of steel but including cost and conveyance of all materials and labour charges etc.,and overheads & contractors profit complete for finished item of work

707

-

84133

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Drilling holes of 25 mm dia and 800mm deep in hard rock or sheet rock with pneumatic compressor and placing of 20mm dia Tor steel bars and grouting the holes in CM(1:2) prop. excluding cost of steel and its fabrication charges but including cost and conveyance of all materials and labour charges etc.,and overheads & contractors profit complete for finished item of work

88

-

14432

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Earth work excavation for foundations for buildings in hard rock (blasting prohibited) and depositing on bank for all lifts and with an initial lead of 10m and up to 3m depth including all operational,incidental, labour charges such as shoring, sheeting, planking, strutting etc., and overheads & contractors profit complete for finished item of work excluding dewatering charges etc., as per SS 20 B(APSS 308)

751

-

1776115

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Earth work excavation for foundations (Mechanical Means) for buildings in ordinary soils and depositing on bank for all lifts and with an initial lead of 10m and up to 3m depth including all operational, incidental, labour charges such as shoring, sheeting, planking, strutting etc., and overheads & contractors profit complete for finished item of work excluding dewatering charges etc., as per SS 20 B(APSS 308).

3278

-

413028

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Conveyance of dismantled concrete/ debris to a distance of 20 KM for disposal including hire charges of T & P, labour charges etc., and overheads & contractors profit complete for finished item of work.

789

-

290825

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Removal of WCs, Urinals & Wash basins disposal of unserviceable materials with 100m lead as directed by Executive Engineer duly taking actual premeasurements before dismantling including all labour charges etc., complete.

63

-

4788

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Dismantling doors , windows and clear storey windows, Ventilators etc., ( wood or steel ) shutters including Chowkhats , architraves,hold fasts and other attachments etc., and stacking them within 100m lead including labour charge etc., and overheads & contractors profit complete for finished item of work Exceeding 3 sqm in area :

105

-

35805

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Dismantling doors , windows and clear storey windows, Ventilators etc., ( wood or steel ) shutters including Chowkhats , architraves,hold fasts and other attachments etc., and stacking them within 100m lead including labour charge etc., and overheads & contractors profit complete for finished item of work Not exceeding 3 sqm in area :

174

-

44196

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Clean removal of cement plaster from walls and raking out joints 20 mm deep or from terraced roof and raking out joints from 50 mm to 100 mm deep

168

-

1848

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Dismantling, clearing away and carefully stacking useful materials for re-use and disposal of unserviceable materials with 100m lead as directed by Executive Engineer duly taking actual premeasurements before dismantling including all labour charges , overheads & contractor profit etc., complete. Old cement mortar plaster

150

-

1650

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Dismantling, clearing away and carefully stacking useful materials for re-use and disposal of unserviceable materials with 100m lead as directed by Executive Engineer duly taking actual premeasurements before dismantling including all labour charges , overheads & contractor profit etc., complete. Kadapa slabs or shahabad stone slabs on sand bed

3336

-

50040

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Dismantling, clearing away and carefully stacking useful materials for re-use and disposal of unserviceable materials with 100m lead as directed by Executive Engineer duly taking actual premeasurements before dismantling including all labour charges , overheads & contractor profit etc., complete. Unreinforced cement concrete more than 15cm thickness (Brick jelly )

99

-

342540

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Dismantling, clearing away and carefully stacking useful materials for re-use and disposal of unserviceable materials with 100m lead as directed by Executive Engineer duly taking actual premeasurements before dismantling including all labour charges , overheads & contractor profit etc., complete. Brick masonry

195

-

56550

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Dismantling, clearing away and carefully stacking useful materials for re-use and disposal of unserviceable materials with 100m lead as directed by Executive Engineer duly taking actual premeasurements before dismantling including all labour charges , overheads & contractor profit etc., complete. Reinforced cement concrete

21

-

79632

... More
Construction of Super Speciality Hospital at Patancheruvu in Sangareddy District.;Clearing Juliflora (Prosafis) jungle including up-rooting and removing of Juliflora stumps including all labour charges.

5016

-

20064



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.