Telangana State Medical Services And Infrastructure Development Corporation Tender
For getting the details of etenders, if you are looking for information about them from the cumbersome government websites but are tired of doing so, Bidassist comes up with a one stop solution. It collates every Eproc telangana tender on Bidassist. One can approach it for the bidding process, registration process, etc., are explained below.
Telangana State Medical Services And Infrastructure Development Corporation - TSMSIDC Tender
Electrical Goods and Equipments
Electrical Generators And Transformers
Electrical and Electronics
Opening Date21 Sep 2024
Closing Date27 Sep 2024
Tender Amount₹ 15,88,611
Costs
EMD
₹ 15,900Document Cost
Refer DocumentsTender Fee
₹ 5,000
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
545557Bid Award Id
ViewTender No
5-1/SE/TGMSIDC Circle/KNR/2024-25, Dt: 05.09.2024Tender Authority
Telangana State Medical Services And Infrastructure Development Corporation ViewPurchaser Address
-Website
http://http://tsmsidc.telangana.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Requirement of 125 KVA Diesel Generator to Area Hospital, Manuguru in Bhadradri Kothagudem District;Termination of UG cables for 3.5 core 120 sqmm XLPE insulated armoured cable with fixing of heavy duty type double compression weather proof type brass cable glands duly nickel plated as per BS 6121 and IP66 complete with brass checknut, outer sheath sealing gasket, with required lugs etc complete. Makes: SMI / Commet / Dowels.
2
1472
2944
Requirement of 125 KVA Diesel Generator to Area Hospital, Manuguru in Bhadradri Kothagudem District;Earth work excavation of Trench in hard ground soil and Sand filling shall be provided at the bottom of trench before laying the cable and laying of U.G cables from 95 Sqmm up to 420 sqmm covering the cable with bricks and back filling of Trench duly providing Cable route Indicators of size 152mm round / 102mm x 102mm / 152mm x 152mm at every 8 Mtrs distance embedded in C.C including cost and conveyance of materials and labour charges etc., complete.
135
256
34560
Requirement of 125 KVA Diesel Generator to Area Hospital, Manuguru in Bhadradri Kothagudem District;Supply of 150 Sqmm 3.5 Core XLPE insulated, 1100V grade armoured alluminium cable with ISI mark as per specification confirming to IS:7098 (Part - I) Makes : Torrent / Unicab / Universal / Polycab / Havells / Gloster / KEI / Finolex / Paragon.
155
1258
194990
Requirement of 125 KVA Diesel Generator to Area Hospital, Manuguru in Bhadradri Kothagudem District;C:AMF Control Panel:- AMF control panel shall be fabricated with 16SWG CRCA sheet shall be totally enclosed with dust and Vermin proof, floor mounted / wall mounted type and shall be comprising the following. 01. Voltmeter with selector switch. 02. 4 Pole MCCB incomer of 250 A rating of Schenieder / L&T make for EB and DG . 03. Ammeter with selector switch with CTs. 04. PF Meter and frequency Meter. 05. Indicator lamps (set Run, Load ON) with fuses. 06. KWH Meter of required rating. 07. Set of control fuses and current transformer. 08. Input Terminal board and output Terminal Board. 09. Battery charger with transformer rectifier unit. 10. Alternator supply air break contactor of L&T make. 11. Main supply air break contactor of L&T make. 12. Audio Visual announciation . 13. Main supply voltage set of control relays and timers with one mode selector switch, set of push buttons. 14.Control cable up to 15 Mtrs 2.5Sqmm 6 Core
-
-
-
Requirement of 125 KVA Diesel Generator to Area Hospital, Manuguru in Bhadradri Kothagudem District;B.Diesel Engine : Kirloskar / Cummins / Mahindra & Mahindra Diesel Engine start, developing suitable 154 BHP, output at 1500 RPM with mechanical / electronic governing so as to enable the alternator to give 160 KVA continuous output at 0.8 P.F. lagging at NTP conditions. The diesel engine shall be capable of providing 10% O/L for 1 Hr for every 11 Hrs of continuous running at full load. The engine with 1st filling of oil and Diesel etc. 01. Exhaust pipe of required size and length with insulation or clading. 02. Diesel tank suitable for 8 to 12 Hours running capacity. 03. Residential Silencer. 04. SMF Batteries with leads as per the Manufacturer standards
-
-
-
Requirement of 125 KVA Diesel Generator to Area Hospital, Manuguru in Bhadradri Kothagudem District;A. Alternator : Kirloskar / Stamford / Crompton Greaves / Leroy Somer make. The alternator of the output rating shall be 3 Phase, 415V, 50Hz, Ac , 0.8 P.F. lagging at 1500 RPM. The alternator is self excited, self regulated, and shall confirm to IS: 13364 of 1992 with regulation of +5% from no load to full load. degree of protections shall be IP21.
-
-
-
Requirement of 125 KVA Diesel Generator to Area Hospital, Manuguru in Bhadradri Kothagudem District;125 KVA Generator Set: Supply, Transportation, erection and commissioning with required CC Foundation as directed of 3 Phase, 415, 50Hz, water cooled multi cylinder diesel generator set with alternator of 125KVA/ 100 KW out put contineous rating directly coupled Engine and Alternator with guard and mounted on a common base plate of Robust construction and complete with standard control panel having IP-52 protection, Acoustic Enclosure as per CPCB norms , sound absorbing material, to restrict sound level up to 75 dB up to 1 mtr distance and as per CPCB norms etc as per following specifications mentioned below.
1
1296945
1296945
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements