Telangana State Medical Services And Infrastructure Development Corporation Tender
For getting the details of etenders, if you are looking for information about them from the cumbersome government websites but are tired of doing so, Bidassist comes up with a one stop solution. It collates every Eproc telangana tender on Bidassist. One can approach it for the bidding process, registration process, etc., are explained below.
Costs
EMD
Refer DocumentsDocument Cost
Refer DocumentsTender Fee
₹ 10,000
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
343394Bid Award Id
ViewTender No
11-7/TSMSIDC/Tech/2022-23, Dt:03/08/2022Tender Authority
Telangana State Medical Services And Infrastructure Development Corporation ViewPurchaser Address
-Website
http://http://tsmsidc.telangana.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Electrical Repairs and Renovations to District Hospital, Medak in Medak District;Supply and fixing of 6A switchs - 2 Nos and 6A 3/2 pin socket - 2 Nos Modular type with cover plate and GI switch box fixing on separate board including all labour charges etc., complete. Makes of switches : Legrand Arteor / Schneider Zen celo / Honeywell Blenge Plus / Crabtree Amare / Logus Platina / Gold Medal GIFA / GM-Zenova/ L&T- Englaze.
15
-
16440
... More
Electrical Repairs and Renovations to District Hospital, Medak in Medak District;Supply and Run of 3 of 2.50 Sq.mm FRLSH / HFFR PVC insulated 1100V grade as per IS:694/1990, IS 17048 specifications for Copper cable. in existing pipe for run of mains inlcuding all labour charges etc., complete. Makes of wires : Finolex / RR kabel / Havells / Gold Medal(HFFR) /Million(HFFR) / KEI (HFFR) / Polycab (HFFR) / DEC(HFFR)
500
-
64000
... More
Electrical Repairs and Renovations to District Hospital, Medak in Medak District;Supply and Run of 3 of 4.00 Sq.mm FRLSH / HFFR PVC insulated 1100V grade as per IS:694/1990, IS 17048 specifications for Copper cable. in existing pipe for run of mains inlcuding all labour charges etc., complete. Makes of wires : Finolex / RR kabel / Havells / Gold Medal(HFFR) /Million(HFFR) / KEI (HFFR) / Polycab (HFFR) / DEC(HFFR)
150
-
27600
... More
Electrical Repairs and Renovations to District Hospital, Medak in Medak District;Supply and Run of 3 of 6.00 Sq.mm FRLSH / HFFR PVC insulated 1100V grade as per IS:694/1990, IS 17048 specifications for Copper cable. in existing pipe for run of mains inlcuding all labour charges etc., complete. Makes of wires : Finolex / RR kabel / Havells / Gold Medal(HFFR) /Million(HFFR) / KEI (HFFR) / Polycab (HFFR) / DEC(HFFR)
100
-
26600
... More
Electrical Repairs and Renovations to District Hospital, Medak in Medak District;Supply and Run of 5 of 6.0 Sq.mm FRLSH / HFFR PVC insulated 1100V grade as per IS:694/1990, IS 17048 specifications for Copper cable. in existing pipe for run of mains inlcuding all labour charges etc., complete. Makes of wires : Finolex / RR kabel / Havells / Gold Medal(HFFR) /Million(HFFR) / KEI (HFFR) / Polycab (HFFR) / DEC(HFFR)
400
-
180000
... More
Electrical Repairs and Renovations to District Hospital, Medak in Medak District;Supply and Run of 5 of 10.0 Sq.mm FRLSH / HFFR PVC insulated 1100V grade as per IS:694/1990, IS 17048 specifications for Copper cable. in existing pipe for run of mains inlcuding all labour charges etc., complete. Makes of wires : Finolex / RR kabel / Havells / Gold Medal(HFFR) /Million(HFFR) / KEI (HFFR) / Polycab (HFFR) / DEC(HFFR)
400
-
269600
... More
Electrical Repairs and Renovations to District Hospital, Medak in Medak District;Supply, transportation and fixing of 22W +/ 10% , >/ 2300 lumens, 1200mm length LED light housing made with aluminum anodised body, wide operating voltage with PF=0.9, Surge protection: > 2KV, THD<10%, with inbuilt driver and frosted cover CCT: 3000K - 6500K as desired by the department as per IS, minimum CRI=80 etc., complete with 5 years warranty with BIS Certification with BIS Certification. LUMINAIRE MAKE: Phillips / OSRAM / GE Venture / Wipro / Crompton / Bajaj / Havells / Jaquar. LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA / OSRAM / SAMSUNG / LG LEDs.
100
-
103800
... More
Electrical Repairs and Renovations to District Hospital, Medak in Medak District;Supply, transportation and fixing ISI mark batten holder / slanting holder Makes : Anchor / Gold Medal Olive / Million Zoom in lieu of ceiling rose of light point complete with all connections and all labour charges with 5W LED Lamp MAKES: Phillips / OSRAM / GE Venture / Wipro / Crompton / Bajaj / Havells / Jaquar / Panasonic / Halonix.
50
-
8450
... More
Electrical Repairs and Renovations to District Hospital, Medak in Medak District;Supply of 48" (1200mm) star rated Sweep Ceiling Fan with all accessories etc., complete. Makes : Crompton HS Plus / Havells ES NEO / Orient Energy Star
50
-
118200
... More
Electrical Repairs and Renovations to District Hospital, Medak in Medak District;Supply and fixing of Modular type Stepped electronic regulator for sweep AC ceiling fans of 1200mm / 1400mm complete with connections. Makes : Legrand Arteor / Schneider Zen celo / Honeywell Blenge Plus / Crabtree Amare / Logus Platina / Gold Medal GIFA / GM-Zenova/ L&T Englaze.
50
-
29850
... More
Electrical Repairs and Renovations to District Hospital, Medak in Medak District;Labour charges for fixing of ceiling fan and regulator including transportation and giving connections with twin core wire etc., complete. Makes : Finolex / RR Kabel / Havells / Polycab / GM / Million / V-Guard / Gold Medal / HPL / RPG.
50
-
8450
... More
Electrical Repairs and Renovations to District Hospital, Medak in Medak District;Supply and erecting 19/20mm steel tube down rod of one meter length with bolts & nuts duly painted with matching colour of fan complete
50
-
7200
... More
Electrical Repairs and Renovations to District Hospital, Medak in Medak District;Supply of 12" (300mm) Light duty exhaust fan with metal blades etc complete Makes : Crompton / Havells Ventilair-DB /Orient hill air.
10
-
17860
... More
Electrical Repairs and Renovations to District Hospital, Medak in Medak District;Supply,Transportation of 12" (300mm) ISI, 900 RPM Heavy duty exhaust fan with metallic blades wiremesh with all accessories etc complete Makes : Crompton / Almonard / Havells Turbo Force SP.
10
-
35210
... More
Electrical Repairs and Renovations to District Hospital, Medak in Medak District;Labour charges for fixing the exhaust fan in wall with necessary connections and masonary work of making hole, finishing etc., complete.
20
-
14300
... More
Electrical Repairs and Renovations to District Hospital, Medak in Medak District;Supply and fixing of 10A 1 Way 1 Module Modular Switch. Makes : Legrand Arteor / Schneider Zen celo / Honeywell Blenge Plus / Crabtree Amare / Logus Platina / Gold Medal GIFA / GM-Zenova/ L&Tenglaze
100
-
13900
... More
Electrical Repairs and Renovations to District Hospital, Medak in Medak District;Supply and fixing of 10A 3/2 Pin 2 Module Modular Socket with shutter. Makes : Legrand Arteor / Schneider Zen celo / Honeywell Blenge Plus / Crabtree Amare / Logus Platina / Gold Medal GIFA / GM-Zenova/ L&Tenglaze
50
-
9950
... More
Electrical Repairs and Renovations to District Hospital, Medak in Medak District;Supply and fixing of 6A 1 Way flush type Switch. Makes : GM G Home / Gold Medal Olive / Million Zoom / Anchor Penta Cherry / Great white Omega / HPL / Vimal / CPL.
100
-
4800
... More
Electrical Repairs and Renovations to District Hospital, Medak in Medak District;Supply and fixing of 6A 3/2 pin flush type Socket with shutter. Makes : GM G Home / Gold Medal Olive / Million Zoom / Anchor Penta Cherry / Great white Omega / HPL / Vimal / CPL.
50
-
2800
... More
Electrical Repairs and Renovations to District Hospital, Medak in Medak District;DISTRIBUTION BOARDSSupply and fixing 20A Plug and Socket with 20A SP MCB with SS enclosure including connections for AC's. DB Make: Legrand / Schneider / Siemens/L&T MCB Make: Legrand-DX3 / Schneider-Acti9 / Siemens
4
-
7948
... More
Electrical Repairs and Renovations to District Hospital, Medak in Medak District;Supply and fixing of 4 Way TPN DB Horizontal with IP 43 Protection as per IS:13032 with 1 No., of 40A FP Isolator as incomer and 12 Nos 6-32 A 10kA SP MCBs as out goings including internal connections and labour charges for FLUSH Mounting etc., complete. (For Lighting DBs) DB Makes : Legrand / Schneider / Siemens / L&T. Isolator & MCB Makes : Legrand-DX3 / Schneider-Acti9 / Siemens / L&T Exora.
8
-
83304
... More
Electrical Repairs and Renovations to District Hospital, Medak in Medak District;Supply and fixing of 4 Way TPN DB Horizontal with IP 43 Protection as per IS:13032 with 1 No., of 63A FP Isolator as incomer and 12 Nos 6-32 A 10kA SP MCBs as out goings including internal connections and labour charges for FLUSH Mounting etc., complete. (For Power DBs) DB Makes : Legrand / Schneider / Siemens / L&T. Isolator & MCB Makes : Legrand-DX3 / Schneider-Acti9 / Siemens / L&T Exora.
8
-
84160
... More
Electrical Repairs and Renovations to District Hospital, Medak in Medak District;Supply and fixing of 4 Way VTPN DB with IP 43 Protection as per IS:13032 with 1 No., of 125A 4P MCCB, Adjustable, Confirms to IS/IEC 60947-2 having Breaking Capacity 25 KA with thermal magnetic release Panel Mounted as incomer with 8 Nos of 63A, 10KA, TP MCBs C Curve ISI Mark as Out goings including internal connections and labour charges etc., complete. DB Makes : Legrand / Schneider / Siemens / L&T. MCCB Makes : L&T- D sine / Schneider-NS NSX/Legrand -DP X3/ Siemens-3VL / Hager-h3/C&S -Winbreak. MCB Makes : Legrand-DX3 / Schneider-Acti9 / Siemens / L&T Exora / Crabtree.
8
-
281024
... More
Electrical Repairs and Renovations to District Hospital, Medak in Medak District;Supply and fixing of 8 Way VTPN DB with IP 43 Protection as per IS:13032 with 1 No., of 125A 4P MCCB, Adjustable, Confirms to IS/IEC 60947-2 having Breaking Capacity 25 KA with thermal magnetic release Panel Mounted as incomer with 8 Nos of 63A, 10KA, TP MCBs C Curve ISI Mark as Out goings including internal connections and labour charges etc., complete. DB Makes : Legrand / Schneider / Siemens / L&T. MCCB Makes : L&T- D sine / Schneider-NS NSX/Legrand -DP X3/ Siemens-3VL / Hager-h3/C&S -Winbreak. MCB Makes : Legrand-DX3 / Schneider-Acti9 / Siemens / L&T Exora / Crabtree.
2
-
92580
... More
Electrical Repairs and Renovations to District Hospital, Medak in Medak District;Supply and Installation of 63A 4 Pole MCCB, Adjustable, Confirms to IS/IEC 60947-2 having Breaking Capacity 16 KA with thermal magnetic release with suitable SS Enclosure and angle iron frame work on wall / floor including all Labours charges massonry work etc complete with connections. Makes : L&T- D shine / Schneider-NS NSX / Legrand -DP X3 / Siemens-3VL / Hager-h3 / C&S -Winbreak.
2
-
23982
... More
Electrical Repairs and Renovations to District Hospital, Medak in Medak District;Supply and Installation of 125 Amps 4 Pole MCCB, Adjustable, Confirms to IS/IEC 60947-2 having Breaking Capacity 25 KA with thermal magnetic release with suitable SS Enclosure and angle iron frame work on wall / floor including all Labours charges massonry work etc complete with connections. Makes : L&T- D shine / Schneider-NS NSX / Legrand -DP X3 / Siemens-3VL / Hager-h3 / C&S -Winbreak.
2
-
37234
... More
Electrical Repairs and Renovations to District Hospital, Medak in Medak District;EARTHINGS: Providing independent earthing for Important equipment with 40mm dia 'B' class 2.5m long G.I pipe and 19mm dia 'B' class G.I pipe of 0.3mtr. long connected with reducer providing G.I funnel with mesh enclosed in C.C/ brick massonry chamber of 450m x 450m x 400mm with R.C.C. Slab cover duly providing staggered holes filling with 20Kg Salt and 40Kg Charcoal or 40Kg bentonite powder from the bottom of the pipe giving earth connection from electrode through G.I strip of 40 x 6mm x 200mm length with all accessories and labour charges complete, as per IS specifications 732/1982 (Part II)
6
-
32274
... More
Electrical Repairs and Renovations to District Hospital, Medak in Medak District;Providing independent earthing by exacavating a pit to a depth of 2.25Mtr in all soils as per size specified in the data for Sophisticated Electronic equipment with 600mm x 600mm x 3.15mm thick copper plate rigidly fixed to 19mm dia 'B' Class G.I Pipe of 2.5Mtr lengthwith funnel as per National Electric Code and earth connection from electrode GI strip of 40mm x 5mm x 200mm length to be bolted with nut bolts to G.I.pipe including 25mm x 3mm copper strip of 6Mtrs length connected from plate to GI strip including filling with 20Kg Salt and 40Kg Charcoal or 40Kg bentonite powder from the bottom of the pipe and providing CC / Brick massonry chamber 450mmX450mmX400mm and covered with R.C.C. Slab including all accessories and labour charges etc complete as per IS specification 732/1982 (Part II).
4
-
61468
... More
Electrical Repairs and Renovations to District Hospital, Medak in Medak District;Supply and Run of 25mm x 6mm G.I Strip including cost of all accessories and labour charges etc., complete. (1.18Kgs/1Mtr)
100
-
11700
... More
Electrical Repairs and Renovations to District Hospital, Medak in Medak District;Supply and Run of 25mm x 3mm copper strip (Cuurrent Carrying Capacity 270A) including cost of all accessories and labour charges etc., complete. (0.663Kgs/1Mtr)
100
-
64400
... More
Electrical Repairs and Renovations to District Hospital, Medak in Medak District;Supply and Run of No.8 SWG G.I wire including cost of all accessories and labour charges etc., complete. (0.104Kgs/1Mtr)
100
-
2100
... More
Electrical Repairs and Renovations to District Hospital, Medak in Medak District;U.G CABLES : Supply of the Following XLPE insulated, 1100V grade armoured alluminium cable with ISI mark as per specification confirming to IS:7098 (Part - I) 3.5 Core 185.00 Sq.mm. Makes : Torrent / Unicab / Universal / Polycab / Havells / Gloster / KEI / Finolex / Paragon.
250
-
341500
... More
Electrical Repairs and Renovations to District Hospital, Medak in Medak District;U.G CABLES : Supply of the Following XLPE insulated, 1100V grade armoured alluminium cable with ISI mark as per specification confirming to IS:7098 (Part - I) 3.5 Core 95.00 Sq.mm. Makes : Torrent / Unicab / Universal / Polycab / Havells / Gloster / KEI / Finolex / Paragon.
300
-
239700
... More
Electrical Repairs and Renovations to District Hospital, Medak in Medak District;U.G CABLES : Supply of the Following XLPE insulated, 1100V grade armoured alluminium cable with ISI mark as per specification confirming to IS:7098 (Part - I) 3.5 Core 70.00 Sq.mm. Makes : Torrent / Unicab / Universal / Polycab / Havells / Gloster / KEI / Finolex / Paragon.
350
-
215250
... More
Electrical Repairs and Renovations to District Hospital, Medak in Medak District;U.G CABLES : Supply of the Following XLPE insulated, 1100V grade armoured alluminium cable with ISI mark as per specification confirming to IS:7098 (Part - I) 3.5 Core 50.00 Sq.mm. Makes : Torrent / Unicab / Universal / Polycab / Havells / Gloster / KEI / Finolex / Paragon.
350
-
166950
... More
Electrical Repairs and Renovations to District Hospital, Medak in Medak District;U.G CABLES : Supply of the Following XLPE insulated, 1100V grade armoured alluminium cable with ISI mark as per specification confirming to IS:7098 (Part - I) 3.5 Core 25.00 Sq.mm. Makes : Torrent / Unicab / Universal / Polycab / Havells / Gloster / KEI / Finolex / Paragon.
200
-
60200
... More
Electrical Repairs and Renovations to District Hospital, Medak in Medak District;Earth work excavation of Trench in hard ground soil and Sand filling shall be provided at the bottom of trench before laying the cable and laying of U.G cables up to 70 sqmm covering the cable with back filling of Trench duly providing Cable route Indicators of size 152mm round / 102mm x 102mm / 152mm x 152mm at every 8 Mtrs distance embedded in C.C including cost and conveyance of materials and labour charges etc., complete.
50
-
11800
... More
Electrical Repairs and Renovations to District Hospital, Medak in Medak District;Earth work excavation of Trench in hard ground soil and Sand filling shall be provided at the bottom of trench before laying the cable and laying of U.G cables from 95 Sqmm up to 400 sqmm covering the cable with bricks and back filling of Trench duly providing Cable route Indicators of size 152mm round / 102mm x 102mm / 152mm x 152mm at every 8 Mtrs distance embedded in C.C including cost and conveyance of materials and labour charges etc., complete.
50
-
12400
... More
Electrical Repairs and Renovations to District Hospital, Medak in Medak District;Laying of PVC armoured under ground cable from 120 Sq.mm to 400 Sqmm fixing on chromium plated metallic base saddles on wall as per IS 1255 and as directed by the department including cost and conveyance of all materials and labour charges etc., complete.
100
-
5100
... More
Electrical Repairs and Renovations to District Hospital, Medak in Medak District;Laying of PVC armoured under ground cable up to 95 Sqmm fixing on chromium plated metallic base saddles on wall as per IS 1255 and as directed by the department including cost and conveyance of all materials and labour charges etc., complete.
100
-
4400
... More
Electrical Repairs and Renovations to District Hospital, Medak in Medak District;LT CABLE TERMINATIONS:Termination of UG cables of including with required Heavy duty cable glands, Lugs complete with all required accessories as directed by the department including cost and conveyance of all materials and labour charges etc., complete. 3.5 Core 185 Sq.mm
10
-
10600
... More
Electrical Repairs and Renovations to District Hospital, Medak in Medak District;LT CABLE TERMINATIONS:Termination of UG cables of including with required Heavy duty cable glands, Lugs complete with all required accessories as directed by the department including cost and conveyance of all materials and labour charges etc., complete. 3.5 Core 95 Sq.mm
10
-
5840
... More
Electrical Repairs and Renovations to District Hospital, Medak in Medak District;LT CABLE TERMINATIONS:Termination of UG cables of including with required Heavy duty cable glands, Lugs complete with all required accessories as directed by the department including cost and conveyance of all materials and labour charges etc., complete. 3.5 Core 70 Sq.mm
10
-
5040
... More
Electrical Repairs and Renovations to District Hospital, Medak in Medak District;LT CABLE TERMINATIONS:Termination of UG cables of including with required Heavy duty cable glands, Lugs complete with all required accessories as directed by the department including cost and conveyance of all materials and labour charges etc., complete. 3.5 Core 50 Sq.mm
10
-
3780
... More
Electrical Repairs and Renovations to District Hospital, Medak in Medak District;LT CABLE TERMINATIONS:Termination of UG cables of including with required Heavy duty cable glands, Lugs complete with all required accessories as directed by the department including cost and conveyance of all materials and labour charges etc., complete. 3.5 Core 25 Sq.mm
20
-
6080
... More
Electrical Repairs and Renovations to District Hospital, Medak in Medak District;Cable Tray : Supply, Transportation and Installation of 300mm x 50mm x 1.6mm thick hot dip GI perforated cable tray without cover along with coupler plates, T's, Bends, Reducers, Anchor bolts, nuts, washers and slotted channels / Angle Iron Channels etc complete and the tray should be fitted on the wall / Ceiling etc. complete for finished item of work. Makes: DEC/MNR/ H FAB or equivalent
300
-
230700
... More
Electrical Repairs and Renovations to District Hospital, Medak in Medak District;Main Power Panel : Supply installation testing and commissioning of 3 phase and neutral 415V free standing floor mounted indoor panel made out of No.16/14 gauge CRCA sheet steel after 7 tank process and painting with powder coating. The panel shall consists of suitable rating TPN Aluminium bus bar ( with rating of 0.8A/ Sqmm)supported with DMC /SMC barriers and colour coaded with heat shrinkable sleeves, necessary cable chamber . The panel shall have comprised of following switch gear . Including supply and fixing the same and painting with powder coating including internal connections cost and conveyance of all materials & labour charges. 800A Aluminium Bus Bar with colour code.(0.8A/Sqmm). Internal wiring with approved make cable Earthing Flat: Providing suitable G.I Flat Incommer: 800A 4 Pole, 50kA, electrically draw out Air Circuit Breaker Confirms to IS 13947-2, IEC 60947-2 and BS-EN 60947 with Micro processer based having overload, shot circuit and earth fault Protection. Makes : Siemens (Sentron- 3WL) / L&T U Power / Schneider Master Pact / ABB Emax / C&S.Winmaster2 / Legrand DMX3 Outgoing:- 400A 4P MCCB, Adjustable, Confirms to IS/IEC 60947-2 having Breaking Capacity 35/36 KA with thermal magnetic release Panel Mounted - 6 No.s Makes : L&T- D sine / Schneider-NS NSX/Legrand -DP X3/ Siemens-3VL / Hager-h3/C&S -Winbreak. 250A 4P MCCB, Adjustable, Confirms to IS/IEC 60947-2 having Breaking Capacity 35/36 KA with thermal magnetic release Panel Mounted - 6 No.s Makes : L&T- D sine / Schneider-NS NSX/Legrand -DP X3/ Siemens-3VL / Hager-h3/C&S -Winbreak. Metering Set: 0- 250A Digital Ammeter with selector switch . - 1 No.(conserve / Elmeasure) 0-500V Digital Volt meter with selector switch - 1 No. (conserve / Elmeasure make) R, Y, B Indication lamps of LED type - 3 Nos. 250/5A C.T coils - 3 Nos. 20A Bakelite Fuse Fittings - 3 Nos. 2A HRC Fuse link - 3 Nos. Labour charges etc complete with connections for Finished item of work.
1
-
816700
... More
Electrical Repairs and Renovations to District Hospital, Medak in Medak District;Sub Power Panel : Supply installation testing and commissioning of 3 phase and neutral 415V free standing floor mounted indoor panel made out of No.16/14 gauge CRCA sheet steel after 7 tank process and painting with powder coating. The panel shall consists of suitable rating TPN Aluminium bus bar ( with rating of 0.8A/ Sqmm)supported with DMC /SMC barriers and colour coaded with heat shrinkable sleeves, necessary cable chamber . The panel shall have comprised of following switch gear . Including supply and fixing the same and painting with powder coating including internal connections cost and conveyance of all materials & labour charges. 600A Aluminium Bus Bar with colour code.(0.8A/Sqmm). Internal wiring with approved make cable Earthing Flat: Providing suitable G.I Flat Incommer: 400A 4P MCCB, Adjustable, Confirms to IS/IEC 60947-2 having Breaking Capacity 35/36 KA with thermal magnetic release Panel Mounted - 1 No.s Makes : L&T- D sine / Schneider-NS NSX/Legrand -DP X3/ Siemens-3VL / Hagerh3/ C&S -Winbreak. Outgoing:- 250 A 4P MCCB, Adjustable, Confirms to IS/IEC 60947-2 having Breaking Capacity 35/36 KA with thermal magnetic release Panel Mounted - 6 No.s Makes : L&T- D sine / Schneider-NS NSX/Legrand -DP X3/ Siemens-3VL / Hagerh3/ C&S -Winbreak. 160 A 4P MCCB, Adjustable, Confirms to IS/IEC 60947-2 having Breaking Capacity 25 KA with thermal magnetic release Panel Mounted - 6 No.s Makes : L&T- D sine / Schneider-NS NSX/Legrand -DP X3/ Siemens-3VL / Hagerh3/ C&S -Winbreak. Metering Set: 0- 250A Digital Ammeter with selector switch . - 1 No.(conserve / Elmeasure) 0-500V Digital Volt meter with selector switch - 1 No. (conserve / Elmeasure make) R, Y, B Indication lamps of LED type - 3 Nos. 250/5A C.T coils - 3 Nos. 20A Bakelite Fuse Fittings - 3 Nos. 2A HRC Fuse link - 3 Nos. Labour charges etc complete with connections for Finished item of work.
1
-
439200
... More
Electrical Repairs and Renovations to District Hospital, Medak in Medak District;Lighting Panel : Supply installation testing and commissioning of 3 phase and neutral 415V free standing floor mounted indoor panel made out of No.16/14 gauge CRCA sheet steel after 7 tank process and painting with powder coating. The panel shall consists of suitable rating TPN Aluminium bus bar ( with rating of 0.8A/ Sqmm)supported with DMC /SMC barriers and colour coaded with heat shrinkable sleeves, necessary cable chamber . The panel shall have comprised of following switch gear . Including supply and fixing the same and painting with powder coating including internal connections cost and conveyance of all materials & labour charges. 400A Aluminium Bus Bar with colour code.(0.8A/Sqmm). Internal wiring with approved make cable Earthing Flat: Providing suitable G.I Flat Incommer: 250 A 4P MCCB, Adjustable, Confirms to IS/IEC 60947-2 having Breaking Capacity 35/36 KA with thermal magnetic release Panel Mounted - 1 No.s Makes : L&T- D sine / Schneider-NS NSX/Legrand -DP X3/ Siemens-3VL / Hagerh3/ C&S -Winbreak. Outgoing:- 125 A 4P MCCB, Adjustable, Confirms to IS/IEC 60947-2 having Breaking Capacity 25 KA with thermal magnetic release Panel Mounted - 3 No.s 63 A 4P MCCB, Adjustable, Confirms to IS/IEC 60947-2 having Breaking Capacity 25 KA with thermal magnetic release Panel Mounted - 3 No.s Metering Set: 0- 250A Digital Ammeter with selector switch . - 1 No.(conserve / Elmeasure) 0-500V Digital Volt meter with selector switch - 1 No. (conserve / Elmeasure make) R, Y, B Indication lamps of LED type - 3 Nos. 250/5A C.T coils - 3 Nos. 20A Bakelite Fuse Fittings - 3 Nos. 2A HRC Fuse link - 3 Nos. Labour charges etc complete with connections for Finished item of work.
1
-
183900
... More
Electrical Repairs and Renovations to District Hospital, Medak in Medak District;500 KVA Copper Wound Transformer : Supply, Transportation, Installation, Testing and Commissioning of 500 KVA Copper Wound Transformer with all test reports. The Transformer shall be designed and manufactured as per IS:1180 OCTC with level-II with initial filling of oil as per IS 335-1993. The basic details of the Transformer are as under. Makes: Kirloskar / PETE / Esennar / Voltamp / Crompton / ABB / Schneider. 1. Quantity : 1 Nos 2.Rated KVA : 500 KVA 3. Service & Location: Continuous Outdoor Distribution Transformer 4. Mounting : Plinth. 5. Wound : Copper Double wound 6. Type : Core type oil immersed 7. Cooling : ONAN 8. Temp Rise : 40°C in oil, 45°C by resistance 9. Vector Group: Dyn 11 10. Primary Connection : Delta 11.Nominal Voltage / Current : 11KV/415V 12. Highest system Voltage: 12000V 13. Primary Frequency :50 HZ +/- 3% 14. Number of Phases : 3 15. Primary wires:3 16. Secondary connection : Star 17. Secondary Volts / Current : 433V/415V 18. Secondary phases : 3 19. Secondary wires: 4 20. Taps on primary winding for primary voltage variation : +5% to - 10% in steps of 2.5% of 7 position (6 Steps) 21. Terminal arrangement. a.HV: HT terminal box as per the site condition. b. LV: Cable box to new 3 phase cables. 22. LV:One separate terminal for earthing. 23. Total Losses at 50% Loading [Watts] [Max] as per IS 24. Total Losses at 100% Loading [Watts] [Max] as per IS 25.Percentage Impedance at 75 deg. C at as per IS 26. No Load current: Less than 2% of full load current. a. Rating and terminal marking plate: One b. Lifting Lugs:Two c. Off-circuit tap switch :One d. Earthing Terminals :Two e. Radiators ( Attachable):Adequate f. Explosion vent with Diaphragm :One g. Conservator with Drain plug:one h. Oil filling hole with cap :One i. Oil level indicator : One j. Dehydrating Silicagel Breather : One k. Terminal Arrangement: HV With Treminal Box l. Terminal Arrangement : LV Cable Box m. Separate Neutral Bushing : One n. Filter valve with blanking plate : One o. Drain cum filter valve with blanking plate : One p. Air release device : One q. Thermometer Pocket : One r. Four :Unidirectional flat rollers s. One :10Cm dial thermometer(Rigid stem type) 27. Standard Fittings & Accessories. a. Rating and terminal marking plate: One b. Lifting Lugs: Two c. Off-circuit tap switch :One d. Earthing Terminals :Two e. Radiators ( Attachable) :Adequate f. Explosion vent with Diaphragm :Oneg. Conservator with Drain plug: one h. Oil filling hole with cap :One i. Oil level indicator : One j. Dehydrating Silica gel Breather : One k. Terminal Arrangement: HV With Terminal Box l. Terminal Arrangement : LV Cable Box m. Separate Neutral Bushing : One n. Filter valve with blanking plate : One o. Drain cum filter valve with blanking plate : One p. Air release device : One q. Thermometer Pocket : One r. Four :Unidirectional flat rollers s. One :10Cm dial thermometer(Rigid stem type)
1
-
1408558
... More
Electrical Repairs and Renovations to District Hospital, Medak in Medak District;130KVAR Out Door Capacitor panel :Supply installation testing and commissioning of 3 phase and neutral 415V free standing floor mounted Outdoor panel made out of No.16/14 gauge CRCA sheet steel after 7 tank process and painting with powder coating. The panel shall consists of suitable rating TPN Aluminium busbar ( with rating of 0.8A/ Sqmm)supported with DMC /SMC barriers and colour coaded with heat shrinkable sleeves, flexibility to accept the up four out going cables and necessary cable chamber . The panel shall have comprised of following switch gear . Including supply and fixing the same and painting with powder coating including internal connections cost and conveyance of all materials & labour charges. Incomer: 250A FP MCCB, Adjustable, Confirms to IS/IEC 60947-2 having Breaking Capacity 36/35 KA with thermal magnetic release Panel Mounted - 1 No Makes of MCCB : L&T- D sine / Schneider-NS NSX / Legrand -DP X3/ Siemens-3VL / Hager-h3/C&S -Winbreak. 63A 10KA TP MCB, C/D Curve ISI Mark Makes : Legrand-DX3 / Shneider-Acti9. - 9 Nos. 20 KVAR Capacitor Duty contactors Makes : L&T / Siemens / EPCOS / Meher. - 5 Nos. 10 KVAR Capacitor Duty contactors Makes : L&T / Siemens / EPCOS / Meher. - 2 Nos. 5 KVAR Capacitor Duty contactors Makes : L&T / Siemens / EPCOS / Meher. - 2 Nos. Supply and fixing of 12 stage APFC Relay with connection etc complete. Makes : L&T / Siemens / EPCOS / Schneider / Elmeasure- 1 No MPP type heavy duty capacitor of operating voltage not less than 480V and losses not more than 0.35W per KVAR and inrush current withstand capability 300 times the rated current.(20KVARx5 Nos.= 100 KVAR, 10KVAR X2 Nos=20 KVAR, 5KVAR X 2 No's=10KVAR). Total = 130KVAR Makes:L&T/Siemens/Schneider/Epcos. 0-415V volt Digital meter of size 96x96mm on existing box / panel board including connections etc., complete of CONZERVE / ELMEASURE / MECO / HPL MAKE. -1 No. 0-100 / 200 / 400 / 600 /1000 - 5A CT Digital Ammeter of size 96x96mm on existing box / panel board including connections etc., complete of CONZERVE / ELMEASURE / MECO / HPL MAKE. - 1 No Analog selector switch for voltmeter / Ammeter on the existing box / panel including connections etc., complete. L&T / C&S / SALZAR / HPL MAKE. - 2 Nos Analog LED indicator lamps on the existing box / panel board.L&T / C&S / SALZAR / HPL MAKE. - 3 Nos 8 Stage APFC Relay with connection etc complete. - 1No. Makes : L&T / Siemens / EPCOS / Schneider / Elmeasure Analog LT current transformer with bar primary 100/5A to 1000 / 5A ratio in the existing box / panel including connections etc., complete. - 3 Nos. KAPPA MAKE. Labour charges etc complete with connections for Finished item of work.
1
-
292200
... More
Electrical Repairs and Renovations to District Hospital, Medak in Medak District;Supply of 3 Core 11 KV 95 Sqmm HT XLPE armoured Cable. As per IS specification confirming to IS 7098/II/85 with latest ammendments.Makes : Torrent / Universal / Polycab / Havells / KEI / RPG / Unicab.
50
-
71450
... More
Electrical Repairs and Renovations to District Hospital, Medak in Medak District;Providing and errecting heat shrinkable indoor termination kit for 11 KV XLPE HT cable 3 core 70-95 Sqmm with necessary materials etc., complete.. Makes : Transeal / Raychem / M Seal.
2
-
22620
... More
Electrical Repairs and Renovations to District Hospital, Medak in Medak District;Providing and errecting heat shrinkable outdoor termination kit for 11 KV XLPE HT cable 3 core 70-95 Sqmm with necessary materials etc., complete with anti tracking red colour material as per IEC / IS specs only. Makes : Transeal / Raychem / M Seal.
2
-
34342
... More
Electrical Repairs and Renovations to District Hospital, Medak in Medak District;Preparation of drawings as required and obtaining of approvals from the CEIG complete as directed by the Department.
1
-
40000
... More
Electrical Repairs and Renovations to District Hospital, Medak in Medak District;11 KV/22 KV Hand gloves
2
-
1084
... More
Electrical Repairs and Renovations to District Hospital, Medak in Medak District;Supply and fixing of PVC synthetic elastomer electrically insulated mat conforming to IS: 15652-2006 with Class B insulation having 2.5mm thickness upto 11KV
2
-
9060
... More
Electrical Repairs and Renovations to District Hospital, Medak in Medak District;Shock instruction chart in English / Hindi / Telugu duly framed with front glass.
2
-
1104
... More
Electrical Repairs and Renovations to District Hospital, Medak in Medak District;Danger Notice Plates of size 250x200mm, shall comply with IS:2551-1982.
2
-
546
... More
Electrical Repairs and Renovations to District Hospital, Medak in Medak District;Providing floor mounting stand for keeping 4No of fire bucket 1500mm length, 900mm height made out of 40x40x6mm angle iron welded with 4 hooks and duly painted with one coat of red lead and two coats of enamel paint.
2
-
2556
... More
Electrical Repairs and Renovations to District Hospital, Medak in Medak District;Supply of round bottom G.I sheet bucket of 9 Ltrs. Capacity as per IS:2546 made out of 24 gauge GI sheet with extra handle at bottom duly painted inside and red out side with printed with FIRE Mark for stand and hook and filled with sand and arranged to existing stand or hook.
8
-
2512
... More
Electrical Repairs and Renovations to District Hospital, Medak in Medak District;First Aid box 18" x 12" x 8" containing material as prescribed by St. John Ambulance brigade OR Indian Red Cross complete as required.
2
-
2896
... More
Electrical Repairs and Renovations to District Hospital, Medak in Medak District;Hot dipped Galvanized Iron Chain link mesh 8 gauge - (4.0 mm) as per IS: 2721-1979: 2"x2"(50mm x 50 mm) - 8Gauge overheads and contractor profit etc., complete for finished item of work.
20
-
30300
... More
Electrical Repairs and Renovations to District Hospital, Medak in Medak District;Supply , fabrication and transportation of MS channel iron/ angle iron /flats including two coats of aluminium paint and one coat of red oxide paint including all labour charges etc complete.
200
-
23800
... More
Electrical Repairs and Renovations to District Hospital, Medak in Medak District;Supply and fixing of gate fixing frame with size 2.1M x 1.25M width fabricated with MS Angle 40x40x6mm fencing frame and the gate of size 1.8M x 1.25M with Angle 35x35x5mm four sides and 40x40x6mm 'T' Angle in middle & M.S weld mesh 2"x2" including painting.
1
-
5200
... More
Electrical Repairs and Renovations to District Hospital, Medak in Medak District;Supply & laying of 40mm HBG metal 4" thick in sub-station including cost and conveyance of all material & sand cushioning 2".
10
-
14600
... More
Electrical Repairs and Renovations to District Hospital, Medak in Medak District;Supply , Fabrication, Transportation and fixing of Box type RS Joist pole made with 2 Nos 175X85 mm ( ISMB Modified ) or equivalent about 30'-0 length / 9.1 Mtrs length poles welded together including excavation of pit, coil earthing, Special T&P, painting of Pole with 1 coat of Red oxide and 2 coats of aluminum paint, CC 1:3:6 up to ground and 1:2:4 for Coping work, 200A AB Switch, HG fuse sets, required angle iron channels, clamps, nuts and bolts, 11KV pin insulators, 2Nos GI pipe earthing as per the IS with brick masonry chamber including labour and transportation charges etc., complete.
1
-
88337
... More
Electrical Repairs and Renovations to District Hospital, Medak in Medak District;Providing transformer plinth 1.2 x 1.2 x 1.5 Mtr in size with necessary excavation in ground at the bottom with 150mm thick 1:2:4 cement concrete raft at the bottom and top and 225mm thick wall constructed in stone masonry and remaking hallow portion shall be filled with stone chips duly plastered 20mm thick outsides including watering etc., complete.
1
-
12805
... More
Electrical Repairs and Renovations to District Hospital, Medak in Medak District;Providing CTPT plinth 600mm x 600mm x 2.1 Mtr in size with necessary excavation in ground at the bottom with 150mm thick 1:2:4 cement concrete raft at the bottom and top duly plastered 20mm thick outsides including watering etc., complete.
1
-
7683