Telangana State Medical Services And Infrastructure Development Corporation Tender

... More
For getting the details of etenders, if you are looking for information about them from the cumbersome government websites but are tired of doing so, Bidassist comes up with a one stop solution. It collates every Eproc telangana tender on Bidassist. One can approach it for the bidding process, registration process, etc., are explained below.

Telangana State Medical Services And Infrastructure Development Corporation - TSMSIDC Tender

Civil And Construction
Building Construction
Opening Date7 Apr 2022
Closing Date22 Apr 2022
Tender Amount₹ 11,91,35,483 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and Installation of Intelligent analogue addressable fault isolator modules including the cost of mounting accessories complete as per specifications and complete as required. Makes: Notifier / Edwards / Honeywell / Morley IAS / Bosch.

12

-

37548

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply of 2 Core x 1.5Sqmm FRLS armoured copper cable as per IS. 7098 / Part-I / 1988 including all taxes etc., complete. Makes: Universal / Unicab / Polycab / Finolex /Havells.

1300

-

122200

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and installation of response indicators for above false ceiling detectors.

10

-

1480

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and installation of UL approved intelligent analogue addressable multi criterion detectors below false ceiling/on ceiling including the cost of base plate. 75mm dia MS outlet box for fixing of the detector base, mounting accessories etc., complete as per specifications and as required. Makes: Notifier / Edwards / Honeywell / Morley IAS / Bos

100

-

328600

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and installation of intalligent analogue addressable rate of rise cum fixed temparature heat detectors including the cost of base plate. 75mm dia MS outlet box for fixing of the detector base, mounting accessories etc., complete as per specifications and as required. Makes: Notifier / Edwards / Honeywell / Morley IAS / Bosch / Honeywell / Morley IAS / Bosch

30

-

93330

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and instllation of UL approved intellegent analogue addressable photo electric smoke detector including cost of base plate etc., complete as per specification with required fittings and accessories. Makes: Siemens / Morley IAS / Bosch / Ravel / Honeywell/cooper

30

-

93870

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and fixing of addressable wall mounting strobes cum hooters including the cost of mounting accessories complete as per specifications and as required including testing and commissioning. Makes: Notifier / Edwards / Honeywell / Morley IAS / Bosch / Honeywell / Morley IAS / Bosch/Cooper

10

-

42790

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply, Installation, testing and commissioning of EN54-2 Listed and LPCB approved 4 loop micro processor based analog addressable fire control panel expandable by minimum 2 additional loops with minimum 80 character LCD display 4in battery condition the panel shall have suitable power amplifiers for hooter / strobes the panel shall be capable beeing integrated with the BMS system and shall include cost of supply, installation of any additional modules or interfaces required for the same. The panel shall be completed as per the specification and as required for fixing of above Micro processor based Fire Alarm control panel with zonal indictions and battery back up as per detailed specifications. Makes: Siemens / Morley IAS / Bosch / Ravel / Honeywell/Cooper access levels 1000 events, historical logging, flash E-PROM, 240 volts A C Power supply, automatic battery charger, 24V SLA batteries suitable for operating the entire system including tack back units and the hooters/strobes for a minimum of 4 hours the panel shall have suitable power amplifiers for hooter / strobes the panel shall be capable being integrated with the BMS system and shall include cost of supply, installation of any additional modules or interfaces required for the same. The panel shall be completed as per the specification and as required for fixing of above Micro processor based Fire Alarm control panel with zonal indictions and battery back up as per detailed specifications. Makes: Notifier / Edwards / Honeywell / Morley IAS / Bosch / Honeywell / Morley IAS / Bosch/ Morley IAS.

1

-

253361

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;FIRE ALARM AND FIRE EXINGUISHERS Fire Alarm Supply and installation of addressable analogue manual call point with resetable flexible element to initiate alaram including the cost of mounting accessories etc. complete. Makes: Siemens / Morley IAS / Bosch / Ravel / Honeywell/cooper.

18

-

71226

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Lifts 20 Persons Bed cum Passenger Lift Supplying, installation, commissioning, testing, putting into operation and handing over of 20 Persons Passenger Lift (1360 Kgs) with following specifications. Make : Kone / OTIS / Johnson / Schindler / MITSUBISHI. I) No. of elevators - 1 ii) Type & Capacity : 20 Passenger Bed cum Passenger lift (1360 Kgs) with Gearless with Machine Room. iii ) Speed Approximately : 1.00m/sec iv) Type of Drive: MICRO PROCESSOR BASED VVVF v) Location of Machine Room: Above Lift well vi) Travel : G+2, 11m Approximately vii) Serving: 4 Stops, 4 Levels and 3 Openings viii) Well Size approximately: 2700 mm wide x 3000 mm deep ix) Power Supply : 415 V, 3 phase 50 Hz, AC x) Auxiliary required: Single Phase 220 V, 50 Hz Ac xi) Car size (clear inside) approx.: 1800 mm wide x 2400 mm deep x 2200 height. xii) Car Enclosure: Stainless Steel Hairline Finish car panels a) Flooring - Aluminium chequered flooring b) Car Illumination : LED Included. xiii) Electric Light/Fan: LED / 400 mm xiv) No. of Entrances: Three at front side. xv) Car Entrance: Stainless Steel Hairline Finish center opening sliding power operated door. xvi) Landing Entrance: Stainless Steel Hairline Finish center opening power door. xvii) Door size : 1200 mm wide x 2000 mm height xviii) Control: Micro Processor based simplex full collective control with or without attendant operation. xix) Indicators: Car & Landings: Dot matrix digital type direction and Position Indicaters with Stainless steel face plates. xx) Other Feature Included: 1.Minor Builders Work 2.Landing Push Button In Landing Door Frames 3.3 Way Intercom / Press And Speak Phone 4.Battery Operated Emergency Light And Alarm Bell 5.Floor Annunciator With Music 6.Automatic Rescue Device 7.Vandal Proof S.S. Button With S.S. Cover 8.Push Button - Orange L E D Illumination 9.Call Register Signal And Vf Door Operator 10.Full Car Operating Panel 11.Dot Matrix Led D & P Indicators In Car & Landings -Orange Colour 12.False Ceiling In Car 13.Firemans Switch 14.Free Service For two Years 15.Infra Red Door Screen 16.Provision For Music 17.Overload Warning Indicator 18. Provision For EPABX 19.Scaffolding 20.SS Handrail 21.Pit Ladder Including Scaffolding, minor building works like chipping, Grouting and pocket cutting.

1

-

2479285

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and fixing of 12V 64 AH SMF battery including wire leads. Makes : Quanta / Racket / Exide.

52

-

413556

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and providing of UPS cum battery rack 5 to 10 batteries

3

-

8520

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and providing of UPS cum battery rack up to 20 batteries

3

-

15678

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply, Transportation and installation of 15KVA / 312V DC on line UPS system IGBT based rectifier with input power factor correction 32 bit microprocessor based with isolation transformers double conversion, SNMP controls, LCD display, Pure sine wave out put, with auto static switch three phase input / Three phase output and modular structure for better thermal technology / cooling facility, with warranty up to three years. Makes: APC / Numeric / Emerson.

1

-

170423

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;UPS Supply, Transportation and installation of 10KVA / 312V DC on line UPS system IGBT based rectifier with input power factor correction 32 bit microprocessor based with isolation transformers double conversion, SNMP controls, LCD display, Pure sine wave out put, with auto static switch three phase input / Three phase output and modular structure for better thermal technology / cooling facility, with warranty up to three years. Makes: APC / Numeric / Emerson.

2

-

295400

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and erecting fully automatic line voltage stabilizer for operation on input voltage 200 to 250V. rated for 5 KVA maximum load and time delay model with Volt meter, selector switch, 6A / 16A flush type, 5 pin socket for out put and with 3 core flexible chord and 3 pin 6/16A plug top suitable for refrigerator for continuous operation including cost and conveyance of all mateials and all labour charges etc., complete. Makes : V-Guard / Real Guard / Uni Stab / ITL.

12

-

43272

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and erecting fully automatic line voltage stabilizer for operation on input voltage 200 to 250V. rated for 4 KVA maximum load and time delay model with Volt meter, selector switch, 6A / 16A flush type, 5 pin socket for out put and with 3 core flexible chord and 3 pin 6/16A plug top suitable for refrigerator for continuous operation including cost and conveyance of all mateials and all labour charges etc., complete. Makes : V-Guard / Real Guard / Uni Stab / ITL.

10

-

30270

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Split Air Conditioners Supply, Transportation and Installation of split AC unit with high wall mounted indoor unit and outdoor condencing unit Hermetically sealed compressor suitable for operation on 230V, 50Hz, 1Phase AC supply capable of performing cooling dehumidifying air circulating and filtering with cooling and condensing units with 3.5 mts of copper piping, insulation kit and 4 mts of 3 core copper flexible chord , built-in stabilizer (Voltage range 160- 264 volts) and cordless remote control complete as directed on the MS Bracket. 2.0 Ton (2-3 STAR) makes Daikin / Thoshiba / O General / Carrier / Blue Star / Hitachi.

12

-

683184

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Split Air Conditioners Supply, Transportation and Installation of split AC unit with high wall mounted indoor unit and outdoor condencing unit Hermetically sealed compressor suitable for operation on 230V, 50Hz, 1Phase AC supply capable of performing cooling dehumidifying air circulating and filtering with cooling and condensing units with 3.5 mts of copper piping, insulation kit and 4 mts of 3 core copper flexible chord , built-in stabilizer (Voltage range 160- 264 volts) and cordless remote control complete as directed on the MS Bracket. 1.5 TR 3 Star capable of delivering 18000 BTU/hr Makes: Daikin / Carrier / Blue Star / Voltas.

10

-

470900

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;LED Street lights Supply, Transportation and fixing of 60 W / 65 W Street light Body made of high grade pressure die ? cast Aluminium alloy with corrosion resistant powder coat, having protective toughened glass cover, Less Glare, IP 66 (Silicon gasket ensures Optical & Electrical compartments are IP 66) protected, wide operating voltage range, P.F > 0.90, System having efficacy >100 lumens/watt, with Ingress protection IP66, Potted driver, Driver surge protection >10KV, THD<15%, CCT: 3000- 6500K as desired by the department and as per IS, CRI>80, Inbuilt Electrical protections like Over voltage, short circuit, Over load, Open Circuit, Miswiring, etc complete with BIS certification with 5 years warranty with fixing of luminaire on wall with 1.0Mt 40mm dia GI pipe bracket and anti-tilting arrangements, 2.5 Sq.mm flexible copper cable including masonary work and all labour charges and giving connections etc., complete. LUMINAIRE MAKE : PHILIPS / OSRAM / GE Venture / CROMPTON / BAJAJ / Wipro / Jaquar / Eveready / Halonix / Keselec / HAVELLS / POLYCAB / SURYA / SYSKA / Capart / Fortune Arrt / FIEM / Panasonic / Arraystorm / GM / Goldmedal LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA / OSRAM / SAMSUNG / LG LEDs.

15

-

122595

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Certificate, Testing and Documentation etc., of each LAN Point complete.

80

-

10000

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply, Transportation and Fixing of 19" 6U floor / Wall mounting net work rack with power spike including all accessories and labour charges etc., complete. Makes : HCL / Vall.

5

-

39505

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and Fixing of 24 port managable switch etc., complete of Make:CISCO / Net Gear / HP / D link.

5

-

36020

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply, Transportation and Fixing of 24 port patch panels including all accessories and labour charges etc., complete. Makes : D Link / AMP / Molex / Legrand / Krone.

5

-

34885

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply of 3 feet length moulded patch cord Makes : D Link / AMP / Molex / Legrand / Krone.

80

-

16400

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply of 7 feet length moulded patch cord Makes : D Link / AMP / Molex / Legrand / Krone.

80

-

18160

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply, Transportation and Fixing of Cat 6 RJ-45 information outlets including duel face plate including all accessories and labour charges etc., complete. Makes : D Link / AMP / Molex / Legrand / Krone.

80

-

34640

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;LAN Supply, Transportation and Run of 1 of LAN Cable cat - 6 UTP cable in the existing cable tray/ conduit pipe and labour charges etc., complete. Makes : D Link / AMP / Molex / Legrand / Krone.

5000

-

180000

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply installation testing and commissioning of Push Button type Telephone Instruments. Makes: Panasonic:

66

-

41976

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply, Installation, Testing and Commissioning of IP Based digtal Telephone (EPABX) system - complied with following specifications: > IP @ Core, PCM/TDM switching, Non blocking, > Must Support PRI, E1, Analog Junctions > Must Support PC Console, > Must support Mobile SIP (Android and IOS) > Must support Voice Mail > Must support Card based GSM > Inbuilt Call Details Software with search engine software > 8 Analog Trunks > 8 Digital Extensions > 128 Analog Extensions > 1 Digital Key Phone with minimum 16 Keys (Must work only on 2 wires) > Expandable to 220 Ports wired or more at extra cost Approved Brands: NEC/ Alcatel/ Karel/Unify

1

-

411212

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply, Transportation and Fixing of 100 pair Telephone distribution box with back mount frame, krone connector, powder coated metal body with lock and key arrangement including all accessories and labour charges etc., complete.

1

-

4326

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply, Transportation and Fixing of 50 pair Telephone distribution box with back mount frame, krone connector, powder coated metal body with lock and key arrangement including all accessories and labour charges etc., complete.

2

-

5024

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply, Transportation and Fixing of 20 pair Telephone distribution box with back mount frame, krone connector, powder coated metal body with lock and key arrangement including all accessories and labour charges etc., complete.

2

-

2590

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply, Transportation and Fixing of 10 pair Telephone distribution box with back mount frame, krone connector, powder coated metal body with lock and key arrangement including all accessories and labour charges etc., complete.

1

-

856

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply, Transportation and Run of 1 of 50 Pair, 0.5mm telephone copper wire Makes : Finolex / Delton / Surabi / Polycab in the existing cable tray/ conduit pipe and labour charges etc., complete.

150

-

32100

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply, Transportation and Run of 1 of 20 Pair, 0.5mm telephone copper wire Makes : Finolex / Delton / Surabi / Polycab in the existing cable tray/ conduit pipe and labour charges etc., complete.

150

-

14100

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply, Transportation and Run of 1 of 10 Pair, 0.5mm telephone copper wire Makes : Finolex / Delton / Surabi / Polycab in the existing cable tray/ conduit pipe and labour charges etc., complete.

100

-

5600

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply, Transportation and Run of 1 of 2 Pair, 0.5mm telephone copper wire Makes : Finolex / Delton / Surabi / Polycab in the existing cable tray/ conduit pipe and labour charges etc., complete.

4200

-

96600

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;EPABX & Telephone system Supply and fixing of Modular telephone Jack with connector on modular box with cover frame in existing consealed pipe wiring including cost and coveyance of all material and all labour charges etc., complete. Makes : GM Four-Five / Legrand Arteor / Schneider Zen celo / Million / Logus / Gold Medal Curve / Anchor Roma viola / CPL / Great White

66

-

16698

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Preparation of Drawings of existing or new installations and obtaining approval from the CEIG complete as per the requirement at site.(AR)

1

-

45000

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;First Aid box 18" x 12" x 8" containing material as prescribed by St. John Ambulance brigade OR Indian Red Cross complete as required.

2

-

2974

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Providing & Supply of round bottom G.I sheet bucket of 9 Ltrs. Capacity as per IS:2546 made out of 24 gauge GI sheet with extra handle at bottom duly painted inside and red out side with printed with FIRE Mark for stand and hook and filled with sand and arranged to existing stand or hook.

16

-

5168

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Providing floor mounting stand for keeping 4No of fire bucket 1500mm length, 900mm height made out of 40x40x6mm angle iron welded with 4 hooks and duly painted with one coat of red lead and two coats of enamel paint.

4

-

5248

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Providing & Fixing of Danger Notice Plates of size 250x200mm, shall comply with IS:2551-1982.

6

-

1686

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Providing & Fixing of Shock instruction chart in English / Hindi / Telugu duly framed with front glass.

3

-

1701

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and fixing of PVC synthetic elastomer electrically insulated mat with Class B insulation conforming to IS:15652-2006 having 2.5mm thickness upto 11KV.

10

-

46530

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Safety Equipments Supply of Rubber hand gloves suitable for 11 kV.

2

-

556

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and spreading, levelling the HT yard with 40mm Coarse aggregate, including cost of all accessories and labour charges etc., complete. including cost and conveyance of all materials and all labour charges and overheads & contractor profits.

20

-

24060

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and erecting double leaf hinged door each 150cms width x 185cms height using 38.1 mm dia B grade ISI marked G.I pipe from all four sides with necessary bends with cross supports of angle iron 40 x 40 x 6mm with the door leaf covered with chain link mesh of No. 8 SWG G.I wire with necessary flat iron covering all around frame. The door shall have heavy latches, and side channels of 100x50x5mm locking arrangement with lock of medium size with duplicate keys, the fencing completely erected with anti corrosive red oxide paint and two coats of prescribed enamel paint / silver paint. The channel iron of size 100x50mm x 2.5Mtr. length shall be provided and erected at both sides of gate with C.C work. including cost and conveyance of all materials and all labour charges and overheads & contractor profits.

1

-

23043

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and erecting 50x50x6mm angle iron as corner support to be fixed away from the fence support fixed at the middle of the fencing frame and the other side in CC foundation of 15x15x40 cms complete duly painted with one coat of red oxide and two coats of aluminium paint. including cost and conveyance of all materials and all labour charges and overheads & contractor profits.

4

-

3612

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Transformer Yard Supply and erecting fencing of section having size 2450 mm in height from ground level and 1200mm width by using angle iron size 50x50x6mm erected in CC foundation 15x15x40cms deep. The section of the frame shall be fitted with flat iron supports of size 25x6mm on top, bottom and middle and chain link jali of 8 SWG G.I to the angle iron at every distance of 30 cms by iron studs complete duly painted with one coat of red oxide and two coats of aluminium paint. including cost and conveyance of all materials and all labour charges and overheads & contractor profits.

18

-

102060

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and Installation of 150mm x 50mm x 1.6 mm thick GI perforated cable tray with out cover along with required angle supports, with coupler plates, Anchor bolts and nuts etc complete and the tray should be fitted on the wall / Ceiling etc. complete for finished item of work for finished item of work.

50

-

21350

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;LT Cable tray Supply, Transportation and Installation of 300mm x 50mm x 1.6mm thick hot dip GI perforated cable tray without cover along with coupler plates, T's, Bends, Reducers, Anchor bolts, nuts, washers and slotted channels / Angle Iron Channels etc complete and the tray should be fitted on the wall / Ceiling etc. complete for finished item of work.

200

-

158000

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;LT Cable Terminations Providing of end termination for the LT Cable with Gland and Aluminium lugs, crimping with machine tool, insulation tape tagging and as directed by the department including cost and conveyance of all materials and labour charges etc., complete. 3.5 Core 120 Sqmm UG Cable

20

-

17140

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;LT Cable Terminations Providing of end termination for the LT Cable with Gland and Aluminium lugs, crimping with machine tool, insulation tape tagging and as directed by the department including cost and conveyance of all materials and labour charges etc., complete. 3.5 Core 70 Sqmm UG Cable

4

-

2080

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;LT Cable Terminations Providing of end termination for the LT Cable with Gland and Aluminium lugs, crimping with machine tool, insulation tape tagging and as directed by the department including cost and conveyance of all materials and labour charges etc., complete. 3.5 Core 35 Sqmm UG Cable

20

-

6460

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;LT Cable Terminations Providing of end termination for the LT Cable with Gland and Aluminium lugs, crimping with machine tool, insulation tape tagging and as directed by the department including cost and conveyance of all materials and labour charges etc., complete. 4 Core 16 Sqmm UG Cable

20

-

4840

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Laying of PVC armoured under ground cable up to 70 Sqmm fixing on chromium plated metallic base saddles on wall / Cable tray as per IS 1255 and as directed by the department including cost and conveyance of all materials and labour charges etc., complete.

600

-

25800

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Laying of PVC armoured under ground cable from 95 Sq.mm to 400 Sqmm fixing on chromium plated metallic base saddles on wall / cable tray as per IS 1255 and as directed by the department including cost and conveyance of all materials and labour charges etc., complete.

100

-

5200

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Earth work excavation of Trench in hard ground soil and Sand filling shall be provided at the bottom of trench before laying the cable and laying of U.G cables up to 70 sqmm covering the cable with back filling of Trench duly providing route indicator embedded in C.C including cost and conveyance of materials and labour charges etc., complete.

50

-

12100

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;LT cable laying Earth work excavation of Trench in hard ground soil and Sand filling shall be provided at the bottom of trench before laying the cable and laying of U.G cables from 95 Sqmm up to 400 sqmm covering the cable with bricks and back filling of Trench duly providing route indicator at every 8 Mtrs distance embedded in C.C including cost and conveyance of materials and labour charges etc., complete.

500

-

126500

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply of the Following PVC XLPE armoured cable 1100 V Grade with ISI mark stranded / solid, aluminium conductor complete Makes : Torrent / Unicab / Universal / Polycab / Havells / Gloster / KEI / Finolex / Paragon / RR kable 120 Sqmm 3.5 Core cable

600

-

605400

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply of the Following PVC XLPE armoured cable 1100 V Grade with ISI mark stranded / solid, aluminium conductor complete Makes : Torrent / Unicab / Universal / Polycab / Havells / Gloster / KEI / Finolex / Paragon / RR kable 70 Sqmm 3.5 Core cable

50

-

31600

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply of the Following PVC XLPE armoured cable 1100 V Grade with ISI mark stranded / solid, aluminium conductor complete Makes : Torrent / Unicab / Universal / Polycab / Havells / Gloster / KEI / Finolex / Paragon / RR kable 35 Sqmm 3.5 Core cable

400

-

148000

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;LT Cable Supply of the Following PVC XLPE armoured cable 1100 V Grade with ISI mark stranded / solid, aluminium conductor complete Makes : Torrent / Unicab / Universal / Polycab / Havells / Gloster / KEI / Finolex / Paragon / RR kable 16 Sqmm 4 Core cable

200

-

48600

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Providing of CC foundations suitable for the 125 KVA DG set complete as directed and as per the norms with all required hard ware materials complete.

1

-

20000

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;AB Switch Supply, Fabrication, Transportation and erection of DP structure made with 2 Nos 175mm x 85mm ( ISMB Modified ) or equivalent about 30'-0 length / 9.1 Mtrs length RS joist pole erection of the same Including excavation of pit in all kinds of soil including breaking stones, concreting with (1:3:6) mixture base plate, coil earthing back filling, 1:2:4 for coping including red oxide primary painting and two coats of aluminium painting etc., complete as required with following as per CEIG norms. a) 400A AB Switch - 1No b) HG Fuse sets - 1No c) LAS-1set. d)Required Number of 11KV pin and disc insulators. e) Required length of 100X50mm and 75X40 mm ISMC channel iron including two coats of red oxide and two coats of enamel paint etc for finished item of work. f) 11KV pin insulators and disc insulators. g) AB switch operating pipe with handle and lock and key arrangements. h). "0" SWG or 8.25 mm dia hard drawn bare copper wire including copper binding wire etc., complete as required including connections. i) 40X6mm GI strip for the DP structure earthing. j) 25X6mm copper strip for lightning arrestors earthing. k) 600X600mmX3,15mm thick copperplate earthing as per NEC with brick masonry chambers - 2 Nos l) GI pipe earthing for the Double pole structure with brick masonry chambers as per IS - 2 Nos

1

-

158783

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply, Providing and errecting heat shrinkable Outdoor termination kit for 11 KV HT XLPE insulated armoured cable 11KV, 3core 120Sqmm with necessary materials etc., complete. Makes : Raychem / Transeal / M Seal

3

-

53739

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply, Providing and errecting heat shrinkable indoor termination kit for 11 KV HT XLPE insulated armoured cable 11KV, 3core 120Sqmm with necessary materials etc., complete. Makes : Raychem / Transeal / M Seal

2

-

23564

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;HT Cable Supply of 3 Core 11 KV 120Sqmm HT XLPE (E) armoured Cable, as per IS specification confirming to IS 7098/II/85 with latest ammendments of Makes : Torrent / Unicab / Universal / Polycab / Havells/ KEI / RPG / Gloster.

100

-

162400

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;125 KVA Generator Set with AMF Panel Supply, Transportation, erection and commissioning (Excluding Foundation) of 3 Phase, 415, 50Hz, water cooled multi cylinder diesel generator set with alternator of 125 KVA out put contineous rating directly coupled Engine and Alternator with guard and mounted on a common base plate of Robust construction and complete with AMF panel having IP-52 protection, Acoustic Enclosure as per CPCB norms, sound absorbing material, to restrict sound level up to 75 dB up to 1 mtr distance and as per CPCB norms etc as per following specifications mentioned below. A. Alternator : Kirloskar / Stamford / Crompton Greaves / Leroy Somer make. The alternator of the output rating shall be 3 Phase, 415V, 50Hz, Ac , 0.8 P.F. lagging at 1500 RPM. The alternator is self excited, self regulated, and shall confirm to IS: 13364 of 1992 with regulation of +5% from no load to full load. degree of protections shall be IP21. B.Diesel Engine : Kirloskar / Cummins / Mahindra & Mahindra / Greaves Cotton / Eicher / Ashok Leyland Diesel Engine start, developing suitable 154 BHP output at 1500 RPM with mechanical / electronic governing so as to enable the alternator to give 125 KVA continuous output at 0.8 P.F. lagging at NTP conditions. The diesel engine shall be capable of providing 10% O/L for 1 Hr for every 11 Hrs of continuous running at full load. The engine with 1st filling of oil and Diesel etc. 01. Exhaust pipe of required size and length with insulation or clading. 02. Diesel tank suitable for 8 to 12 Hours running capacity. 03. Residential Silencer. 04. SMF Batteries with leads as per the Manufacturer standards C. AMF Control Panel:- AMF control panel shall be fabricated with 16SWG CRCA sheet shall be totally enclosed with dust and Vermin proof, floor mounted / wall mounted type and shall be comprising the following. 01. Voltmeter with selector switch. 02. 250A 4 Pole MCCB incomer of rating of Schenieder / L&T make for EB and DG . 03. Ammeter with selector switch with CTs. 04. PF Meter and frequency Meter. 05. Indicator lamps (set Run, Load ON) with fuses. 06. KWH Meter of required rating. 07. Set of control fuses and current transformer. 08. Input Terminal board and output Terminal Board. 09. Battery charger with transformer rectifier unit. 10. Alternator supply air break contactor of L&T make. 11. Main supply air break contactor of L&T make. 12. Audio Visual announciation . 13. Main supply voltage set of control relays and timers with one mode selector switch, set of push buttons. 14.Control cable up to 15 Mtrs 2.5Sqmm 6 Core

1

-

1336530

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;315 KVA Transformers Supply, Transportation, Installation, Testing and Commissioning of 315KVA Transformer with all test reports. The Transformer shall be designed and manufactured as per IS:1180 OCTC with level-II with initial filling of oil as per IS 335-1993. The basic details of the Transformer are as Under. Makes: Kirloskar / PETE / Esennar / Voltamp / Crompton / ABB / Schneider. 1. Quantity: 1 Nos 2. Rated KVA: 315 KVA 3. Service & Location: Continuous Outdoor Distribution Transformer 4. Mounting: Plinth. 5. Wound: Copper Double wound 6. Type: Core type oil immersed 7. Cooling: ONAN 8. Temp Rise: 40°C in oil, 45°C by resistance 9. Vector Group Dyn 11 10. Primary Connection: Delta 11. Nominal Voltage / Current: 11KV/415V, 52A/1390A              12. Highest system Voltage: 12000V 13. Primary Frequency: 50 HZ +/- 3% 14. Number of Phases: 3 15. Primary wires: 3 16. Secondary connection: Star 17. Secondary Volts / Current: 433V 18. Secondary phases:: 3 19. Secondary wires: 4 20. Taps on primary winding for primary voltage variation : +5% to - 10% in steps of 2.5% of 7 position (6 Steps). 21. Terminal arrangement. a. HV: HT terminal box as per the site condition. b. LV: Cable box suitable to receive 1600A Air bus duct 22. LV:One separate terminal for earthing. 23. Total Losses at 50% Loading [Watts] [Max] as per IS 24. Total Losses at 100% Loading [Watts] [Max] as per IS 25.Percentage Impedance at 75 deg. C at ----- as per IS 26. No Load current: Less than 2% of full load current. a. Rating and terminal marking plate: One b. Lifting Lugs:Two c. Off-circuit tap switch :One d. Earthing Terminals :Two e. Radiators ( Attachable):Adequate f. Explosion vent with Diaphragm :One g. Conservator with Drain plug:one h. Oil filling hole with cap :One i. Oil level indicator : One j. Dehydrating Silicagel Breather : One k. Terminal Arrangement: HV With Terminal Box l. Terminal Arrangement : LV Cable Box m. Separate Neutral Bushing : One n. Filter valve with blanking plate : One o. Drain cum filter valve with blanking plate : One p. Air release device : One q. Thermometer Pocket : One r. Four :Unidirectional flat rollers s. One :10Cm dial thermometer(Rigid stem type)

1

-

1102292

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and Installation of 125 Amps 4 Pole MCCB, Adjustable, Confirms to IS/IEC 60947-2 having Breaking Capacity 25 KA with thermal magnetic release with suitable SS Enclosure and angle iron frame work on wall / floor including all Labours charges massonry work etc complete with connections. Makes : L&T- D shine / Schneider-NS NSX / Legrand -DP X3 / Siemens-3VL / Hager-h3 / C&S -Winbreak.

2

-

38242

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and Installation of 63A 4 Pole MCCB, Adjustable, Confirms to IS/IEC 60947-2 having Breaking Capacity 16 KA with thermal magnetic release with suitable SS Enclosure and angle iron frame work on wall / floor including all Labours charges massonry work etc complete with connections. Makes : L&T- D shine / Schneider-NS NSX / Legrand -DP X3 / Siemens-3VL / Hager-h3 / C&S -Winbreak.

3

-

36948

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;APFCR panel for 125 KVAR Supply installation testing and commissioning of 3 phase and neutral 415V free standing floor mounted indoor Type MV panel made out of No.16/14 gauge CRCA sheet steel after 7 tank process and painting with powder coating. The panel shall consists of suitable rating TPN Alluminium busbar ( with rating of 0.8A/ Sqmm)supported with DMC /SMC barriers and colour coaded with heat shrinkable sleeves, flexibiltioy to accept the up four out going cables and necessary cable chamber . The panel shall have comprised of following switch gear . Including supply and fixing the same and painting with powder coating including internal connections cost and conveyance of all materials & labour charges. INCOMER: 250A 4 Pole MCCB / Confirms to IS/IEC 60947-2 having Breaking Capacity 35/36 KA with thermal magnetic release Panel Mounted, arrangement with all connections etc., complete on existing panel Makes: L&T- D shine / Schneider-NS NSX/Legrand -DP X3/ Siemens-3VL / Hagerh3/ C&S -Winbreak2/HPL-Techno.- 1 Nos 125A 3 Pole MCCB, Adjustable, Confirms to IS/IEC 60947-2 having Breaking Capacity 25 KA with thermal magnetic release Panel Mounted. - 1 Nos Makes : L&T / Schneider / Siemens / Legrand / Hager / ABB / C&S. Supply of 40-63A TP MCB 10KA, C/D Curve ISI Mark. Makes : Legrand-DX3 / Schneider-Acti9 / Siemens / L&T Exora / Crabtree. - 3 Nos Supply of 6-32A TP MCB 10KA, C/D Curve ISI Mark. Makes : Legrand-DX3 / Schneider-Acti9 / Siemens / L&T Exora / Crabtree. - 4 Nos MPP type heavy duty capacitor of operating voltage not less than 480V and losses not more than 0.35W per KVAR and inrush current withstand capability 300 times the rated current. Makes:L&T/Siemens/ Schneider/Epcos - ( 1Nos x 50 KVAr ) + (3 Nos x 15 KVAr) + (2 Nos x 10 KVAr) + (2 Nos x 5 KVAr) with respective rated capacitor duty contactors 0-415V volt Digital meter of size 96x96mm on exisiting box / panel board including connections etc., complete of CONZERVE / ELMEASURE / MECO / HPL MAKE. - 1 No. 0-100 / 200 / 400 / 600 /1000 - 5A CT Digital Ammeter of size 96x96mm on existing box / panel board including connections etc., complete of CONZERVE / ELMEASURE / MECO / HPL MAKE. - 1 No. Supply and fixing of 8 Stage APFC Relay with connection etc complete. Makes : L&T / Siemens / EPCOS / Schneider / Elmeasure Analog selector switch for voltmeter / Ammeter on the existing box / panel including connections etc., complete. L&T / C&S / SALZAR / HPL MAKE. - 2 Nos Push buttons on the existing panel board. L&T / C&S / SALZAR / HPL MAKE. - 16 Nos. Analog LED indicator lamps on the existing box / panel board.L&T / C&S / SALZAR / HPL MAKE. - 24 Nos. Analog LT current transformer with bar primary 100/5A to 1000 / 5A ratio in the existing box / panel including connections etc., complete. KAPPA MAKE. - 3 Nos. Labour charges etc complete with connections for Finished item of work.

1

-

258500

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;GF Lighting Sub Panel Supply installation testing and commissioning of 3 phase and neutral 415V free standing floor mounted indoor Type MV panel made out of No.16/14 gauge CRCA sheet steel after 7 tank process and painting with powder coating. The panel shall consists of suitable rating TPN Alluminium busbar ( with rating of 0.8A/ Sqmm ) supported with DMC /SMC barriers and colour coaded with heat shrinkable sleeves, flexibiltioy to accept the up four out going cables and necessary cable chamber . The panel shall have comprised of following switch gear . Including supply and fixing the same and painting with powder coating including internal connections cost and conveyance of all materials & labour charges. INCOMER: 160A 4P MCCB, Adjustable, Confirms to IS/IEC 60947-2 having Breaking Capacity 25 KA with thermal magnetic release Panel Mounted as incomer - 1 No. Makes : L&T- D sine / Schneider-NS NSX/Legrand -DP X3/ Siemens-3VL / Hagerh3/C&S -Winbreak. 63A 3 Pole MCCB, Adjustable, Confirms to IS/IEC 60947-2 having Breaking Capacity 16 KA with thermal magnetic release Panel Mounted. - 2 Nos Makes : L&T / Schneider / Siemens / Legrand / Hager / ABB / C&S. 63A 10KA TP MCB, C/D Curve ISI Mark - 6 Nos Makes : Legrand-DX3 / Schneider-Acti9 / Siemens / L&T Exora / Cabtree. 0-415V volt Digital meter of size 96x96mm on exisiting box / panel board including connections etc., complete of CONZERVE / ELMEASURE / MECO / HPL MAKE. - 1 No. 0-100 / 200 / 400 / 600 /1000 - 5A CT Digital Ammeter of size 96x96mm on existing box / panel board including connections etc., complete of CONZERVE / ELMEASURE / MECO / HPL MAKE. - 1 No. Analog selector switch for voltmeter / Ammeter on the existing box / panel including connections etc., complete. L&T / C&S / SALZAR / HPL MAKE. - 2 Nos Analog LED indicator lamps on the existing box / panel board. L&T / C&S / SALZAR / HPL MAKE - 3 Nos. Analog LT current transformer with bar primary 100/5A to 1000 / 5A ratio in the existing box / panel including connections etc., complete. KAPPA MAKE - 3 Nos. Labour charges etc complete with connections for Finished item of work.

1

-

121800

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;GF Power Sub Panel Supply installation testing and commissioning of 3 phase and neutral 415V free standing floor mounted indoor Type MV panel made out of No.16/14 gauge CRCA sheet steel after 7 tank process and painting with powder coating. The panel shall consists of suitable rating TPN Alluminium busbar ( with rating of 0.8A/ Sqmm)supported with DMC /SMC barriers and colour coaded with heat shrinkable sleeves, flexibiltioy to accept the up four out going cables and necessary cable chamber . The panel shall have comprised of following switch gear . Including supply and fixing the same and painting with powder coating including internal connections cost and conveyance of all materials & labour charges. INCOMER: 250A 4P MCCB, Adjustable, Confirms to IS/IEC 60947-2 having Breaking Capacity 35 kA with thermal magnetic release Panel Mounted as incomer. - 1 No. Makes : L&T- D sine / Schneider-NS NSX/Legrand -DP X3/ Siemens-3VL / Hagerh3/C&S -Winbreak. 125A 3 Pole MCCB, Adjustable, Confirms to IS/IEC 60947-2 having Breaking Capacity 25 KA with thermal magnetic release Panel Mounted. - 2 Nos Makes : L&T / Schneider / Siemens / Legrand / Hager / ABB / C&S. 63A 3 Pole MCCB, Adjustable, Confirms to IS/IEC 60947-2 having Breaking Capacity 16 KA with thermal magnetic release Panel Mounted. - 6 Nos Makes : L&T / Schneider / Siemens / Legrand / Hager / ABB / C&S. 0-415V volt Digital meter of size 96x96mm on exisiting box / panel board including connections etc., complete of CONZERVE / ELMEASURE / MECO / HPL MAKE. - 1 No. 0-100 / 200 / 400 / 600 /1000 - 5A CT Digital Ammeter of size 96x96mm on existing box / panel board including connections etc., complete of CONZERVE / ELMEASURE / MECO / HPL MAKE. - 1 No. Analog selector switch for voltmeter / Ammeter on the existing box / panel including connections etc., complete. L&T / C&S / SALZAR / HPL MAKE. - 2 Nos Analog LED indicator lamps on the existing box / panel board.L&T / C&S / SALZAR / HPL MAKE - 3 Nos. Analog LT current transformer with bar primary 100/5A to 1000 / 5A ratio in the existing box / panel including connections etc., complete. KAPPA MAKE - 3 Nos. Labour charges etc complete with connections for Finished item of work.

1

-

164200

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Main Lighting Panel Supply installation testing and commissioning of 3 phase and neutral 415V free standing floor mounted Indoor Type MV panel made out of No.16/14 gauge CRCA sheet steel after 7 tank process and painting with powder coating. The panel shall consists of suitable rating TPN Alluminium busbar ( with rating of 0.8A/ Sqmm)supported with DMC /SMC barriers and colour coaded with heat shrinkable sleeves, flexibiltioy to accept the up four out going cables and necessary cable chamber . The panel shall have comprised of following switch gear . Including supply and fixing the same and painting with powder coating including internal connections cost and conveyance of all materials & labour charges. INCOMER: 250A 4 Pole MCCB, Adjustable, Confirms to IS/IEC 60947-2 having Breaking Capacity 35 KA with thermal magnetic release Panel Mounted. Makes : L&T / Schneider / Siemens / Legrand / Hager / ABB / C&S. as incomer. - 1 Nos. 160A 3P MCCB, Adjustable, Confirms to IS/IEC 60947-2 having Breaking Capacity 25 KA with thermal magnetic release Panel Mounted as incomer. - 1 Nos Makes : L&T- D sine / Schneider-NS NSX/Legrand -DP X3/ Siemens-3VL / Hagerh3/ C&S -Winbreak. 125A 3 Pole MCCB, Adjustable, Confirms to IS/IEC 60947-2 having Breaking Capacity 25 KA with thermal magnetic release Panel Mounted. - 5 Nos Makes : L&T / Schneider / Siemens / Legrand / Hager / ABB / C&S. 63A 3 Pole MCCB, Adjustable, Confirms to IS/IEC 60947-2 having Breaking Capacity 16 KA with thermal magnetic release Panel Mounted. - 2 Nos Makes : L&T / Schneider / Siemens / Legrand / Hager / ABB / C&S. 0-415V volt Digital meter of size 96x96mm on exisiting box / panel board including connections etc., complete of CONZERVE / ELMEASURE / MECO / HPL MAKE. - 1 No. 0-100 / 200 / 400 / 600 /1000 - 5A CT Digital Ammeter of size 96x96mm on existing box / panel board including connections etc., complete of CONZERVE / ELMEASURE / MECO / HPL MAKE. - 1 No. Analog selector switch for voltmeter / Ammeter on the existing box / panel including connections etc., complete. L&T / C&S / SALZAR / HPL MAKE. - 2 Nos Analog LED indicator lamps on the existing box / panel board.L&T / C&S / SALZAR / HPL MAKE. - 3 Nos. Analog LT current transformer with bar primary 100/5A to 1000 / 5A ratio in the existing box / panel including connections etc., complete. KAPPA MAKE. - 3 Nos. Labour charges etc complete with connections for Finished item of work.

1

-

217200

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Panel Boards Main Power Panel Supply installation testing and commissioning of 3 phase and neutral 415V free standing floor mounted Indoor Type MV panel made out of No.16/14 gauge CRCA sheet steel after 7 tank process and painting with powder coating. The panel shall consists of suitable rating TPN Alluminium busbar ( with rating of 0.8A/ Sqmm ) supported with DMC /SMC barriers and colour coaded with heat shrinkable sleeves, flexibiltioy to accept the up four out going cables and necessary cable chamber. The panel shall have comprised of following switch gear . Including supply and fixing the same and painting with powder coating including internal connections cost and conveyance of all materials & labour charges. INCOMER: 630A 4 Pole, 50kA, electrically draw out Air Circuit Breaker Confirms to IS 13947-2, IEC 60947-2 and BS-EN 60947 with Micro processer based having overload, shot circuit and earth fault Protection. Makes : Siemens (Sentron- 3WL) / L&T U Power / Schneider Master Pact / ABB Emax / C&S Winmaster2 / Legrand DMX3 - 1 No 250A 3P MCCB, Adjustable, Confirms to IS/IEC 60947-2 having Breaking Capacity 35 KA with thermal magnetic release Panel Mounted. - 1 Nos Makes : L&T- D sine / Schneider-NS NSX/Legrand -DP X3/ Siemens-3VL / Hagerh3/ C&S -Winbreak. - 4 Nos Supply of 125A 3 Pole MCCB, Adjustable, Confirms to IS/IEC 60947-2 having Breaking Capacity 25 KA with thermal magnetic release Panel Mounted. Makes : L&T / Schneider / Siemens / Legrand / Hager / ABB / C&S - 5 Nos Supply of 63A 3 Pole MCCB, Adjustable, Confirms to IS/IEC 60947-2 having Breaking Capacity 16 KA with thermal magnetic release Panel Mounted.Makes : L&T / Schneider / Siemens / Legrand / Hager / ABB / C&S - 2 Nos Supply of 63A 10KA TP MCB, C/D Curve ISI Mark Makes : Legrand-DX3 / Schneider-Acti9 / Siemens / L&T Exora / Cabtree. - 2 nos 0-415V volt Digital meter of size 96x96mm on exisiting box / panel board including connections etc., complete of CONZERVE / ELMEASURE / MECO / HPL MAKE. - 1 No. 0-100 / 200 / 400 / 600 /1000 - 5A CT Digital Ammeter of size 96x96mm on existing box / panel board including connections etc., complete of CONZERVE / ELMEASURE / MECO / HPL MAKE. - 1 No. Analog selector switch for voltmeter / Ammeter on the existing box / panel including connections etc., complete. L&T / C&S / SALZAR / HPL MAKE. - 2 Nos Analog LED indicator lamps on the existing box / panel board.L&T / C&S / SALZAR / HPL MAKE. - 3 Nos. Analog LT current transformer with bar primary 100/5A to 1000 / 5A ratio in the existing box / panel including connections etc., complete. KAPPA MAKE. - 3 Nos. Labour charges etc complete with connections for Finished item of work.

1

-

583900

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and fixing of louver shutter suitable for 12" Exhaust fan including all labour charges etc complete with connections and colouring matching to the wall with enamel paint.

44

-

8316

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Labour charges for fixing of Exhaust fan in wall with necessary connections and masonary work including material of making hole, finishing etc., complete.

44

-

32296

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply,Transportation of 12" (300mm) ISI, 900 RPM Heavy duty exhaust fan with metallic blades wiremesh with all accessories etc complete. Makes : Crompton / Almounard / Havells Turbo Force.

30

-

108510

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply,Transportation of light duty exhaust fan 12"(300 mm) size 900 rpm with metal blades wiremesh with all accessories etc complete. Makes : Crompton / Bajaj Bahar WG / Havells Ventil Air-DB / Orient hill air.

14

-

25676

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and erecting 19/20mm steel tube down rod of one meter length with bolts & nuts duly painted with matching colour of fan complete.

203

-

30247

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Labour charges for Fixing of Ceiling fan including giving connections with twin core wire etc., complete.

203

-

35322

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and fixing of modular Electronic step type fan regulator hum free step type socket size with MS box, front plate in the existing switch board. ( Modular Type ). Makes - Legrand Arteor / Schneider Zen celo / Honeywell Blenge Plus / Cabtree Amare / Logus Platina / Gold Medal GIFA / GM-Zenova / L&T- Englaze.

203

-

124642

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply of 48" (1200mm) 5 star rated Sweep Ceiling Fan with all accessories etc., complete but without Regulator. Makes : Crompton HS Plus / Havells ES NEO / Orient Energy Star.

203

-

492884

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and fixing of Remote bell including giving connections cost of all accessories and all labour charges etc., complete. Makes: GM / Gold Medal / Million / Vimal / Anchor.

5

-

3970

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and fixing of Electronic Music bell on 6" x 8" decolam block including giving connections, cost of all accessories and labour charges etc., complete. Makes: GM / Gold Medal / Million / Vimal / Anchor

5

-

2035

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and fixing of Ding Dong Bell of Makes : GM / Million / Gold Medal / Anchor / Great white on 4"x7" decolam block including giving connections, cost of all accessories and labour charges etc., complete.

10

-

2140

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply, transportation and fixing ISI mark batten holder / slanting holder Makes : Anchor / Gold Medal Olive / Million Zoom in lieu of ceiling rose of light point complete with all connections and all labour charges with 5W LED Lamp MAKES: Phillips / OSRAM / GE Venture / Wipro / Crompton / Bajaj / Havells / Jaquar / Panasonic / Halonix. Holder Make: GM G Home / Gold Medal Olive / Million Zoom / Anchor Penta Cherry / Great white Omega / HPL / Vimal / CPL.

68

-

15096

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply, Transportation and fixing of 18W Down lighter with system lumens of 1000lm, suitable for Recessed / Surface mounting square type, made of pressure die cast aluminum body with powder coating, acrylic diffuser with Driver, operating voltage range of 150 to 265 Volts AC, P.F = 0.9, Surge protection: 2KV, THD<15%, with high power LED's having efficacy of = 100 lumens/watt,CCT: 3000K - 5700K, minimum CRI=70,.etc., complete with 3 years warranty. LUMINAIRE MAKE : Phillips / OSRAM / Wipro / Crompton / Bajaj / Havells / Jaquar / IB LED / Panasonic / Halonix / HPL / Syska / Eveready / Surya / Keselec / FIEM / Arraystorm / GM / Goldmedal LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA / OSRAM / SAMSUNG / LG LEDs.

55

-

112915

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and Transportation of 45W, 2' x2' (600mm x 600mm) slim panel LED luminaire (Industrial Application) Square Housing Made of Aluminum alloy with corrosion resistant powder coat, with acrylic diffuser, Constant current out put of Driver operating voltage range of 150 to 265 Volts AC, Power factor = 0.9 high power LEDs having efficacy of = 100 lumens/watt, junction temperature less than 85 degrees centigrade and THD is less than 12% etc., complete. LUMINAIRE MAKE: Phillips / OSRAM / GE Venture / Wipro / Crompton / Bajaj / Havells / Jaquar / IB LED / Panasonic / Halonix / HPL / Syska / Eveready / Surya / Keselec/ FIEM / Arraystorm / GM / Goldmedal LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA / OSRAM / SAMSUNG / LG LEDs.

10

-

49630

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and Transportation of 36W, 2' x2' (600mm x 600mm) slim panel LED luminaire (Industrial Application) Square Housing Made of Aluminum alloy with corrosion resistant powder coat, with acrylic diffuser, Constant current out put of Driver operating voltage range of 150 to 265 Volts AC, Power factor = 0.9 high power LEDs having efficacy of = 100 lumens/watt, junction temperature less than 85 degrees centigrade and THD is less than 12% etc., complete. LUMINAIRE MAKE: Phillips / OSRAM / GE Venture / Wipro / Crompton / Bajaj / Havells / Jaquar / IB LED / Panasonic / Halonix / HPL / Syska / Eveready / Surya / Keselec / Arraystorm / GM / Goldmedal LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA / OSRAM / SAMSUNG / LG LEDs.

45

-

193680

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply, transportation and fixing of 10W, 1000 lumens, 600mm length LED batten tube light, housing made with PC body, wide operating voltage with Single / double side connection, PF=0.9, Surge protection: > 2KV, THD<15%, with inbuilt driver and frosted cover CCT: 3000K - 6500K as desired by the department and as per IS specifications, minimum CRI=80,.etc complete with 5 years warranty with BIS Certification and all labour charges etc. LUMINAIRE MAKE: Phillips / OSRAM / GE Venture / Wipro / Crompton / Bajaj / Havells / Jaquar / IB LED / Panasonic / Halonix / HPL / Syska / Eveready / Surya / Keselec / Arraystorm / GM / Goldmedal LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA / OSRAM / SAMSUNG / LG LEDs.

30

-

21750

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Light Fixtures Supply, transportation and fixing of 22W,+/ 10% , >/ 2300 lumens, 1200mm length LED light housing made with alluminium anodised body, wide operating voltage with PF=0.9, Surge protection: > 2KV, THD<10%, with inbuilt driver and frosted cover CCT: 3000K - 6500K as desired by the department as per IS, minimum CRI=80 etc., complete with 5 years warranty with BIS Certification with BIS Certification. LUMINAIRE MAKE: Phillips / OSRAM / GE Venture / Wipro / Crompton / Bajaj / Havells / Jaquar / IB LED / Panasonic / Halonix / HPL / Syska / Eveready / Surya / Keselec/ FIEM / Arraystorm / GM / Goldmedal LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA / OSRAM / SAMSUNG / LG LEDs.

360

-

383760

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and run of No. 8SWG GI wire including cost of all accessories and labour charges etc complete.

150

-

3300

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and Run of 25mm x 6mm copper strip including cost of all accessories and labour charges etc., complete.

50

-

66100

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and Run of 25mm x 3mm copper strip including cost of all accessories and labour charges etc., complete.

100

-

66100

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and Run of 50mm x 6mm G.I Strip including cost of all accessories and labour charges etc., complete.

100

-

24100

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and Run of 25mm x 6mm G.I Strip including cost of all accessories and labour charges etc., complete.

150

-

18000

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Providing independent earthing for Important equipment with 100mm dia Heavy gauge C.I (Cast iron ) pipe with Flange 2.5m long enclosed in C.C/ brick masonry chamber of 450m x 450m x 400mm with R.C.C. Slab cover duly providing staggered holes filling with salt and charcoal from the bottom of the pipe giving earth connection from electrode through flange with all accessories and labour charges complete, as per IS specifications 732/1982 (Part II).

2

-

19728

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Providing independent earthing by exacavating a pit to a depth of 2.25Mtr in all soils as per size specified in the data for Sophisticated Electronic equipment with 600mm x 600mm x 3.15mm thick copper plate rigidly fixed to 19mm dia 'B' Class G.I Pipe of 2.5Mtr lengthwith funnel as per National Electric Code and earth connection from electrode GI strip of 40mm x 5mm x 200mm length to be bolted with nut bolts to G.I.pipe including 25mm x 3mm copper strip of 6Mtrs length connected from plate to GI strip including filling with 20Kg Salt and 40Kg Charcoal or 40Kg bentonite powder from the bottom of the pipe and providing CC / Brick massonry chamber 450mmX450mmX400mm and covered with R.C.C. Slab including all accessories and labour charges etc complete as per IS specification 732/1982 (Part II).

6

-

94698

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Earthings Providing independent earthing for Important equipment with 40mm dia 'B' class 2.5m long G.I pipe and 19mm dia 'B' class G.I pipe of 0.3mtr. long connected with reducer providing G.I funnel with mesh enclosed in C.C/ brick massonry chamber of 450m x 450m x 400mm with R.C.C. Slab cover duly providing staggered holes filling with 20Kg Salt and 40Kg Charcoal or 40Kg bentonite powder from the bottom of the pipe giving earth connection from electrode through G.I strip of 40 x 6mm x 200mm length with all accessories and labour charges complete, as per IS specifications 732/1982 (Part II)

8

-

44200

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and fixing of cable adopteres box with cover for DBs including, massanory work etc., complete, Makes : Legrand / Schneider / Siemens / L&T.

49

-

29400

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and fixing of 8 Way VTPN DB with IP 43 Protection as per IS:13032 with 1 No., of 125A 4P MCCB, Adjustable, Confirms to IS/IEC 60947-2 having Breaking Capacity 25 KA with thermal magnetic release Panel Mounted as incomer with 8 Nos of 63A, 10KA, TP MCBs C Curve ISI Mark as Out goings including internal connections and labour charges for FLUSH Mounting etc., complete. DB Makes : Legrand / Schneider / Siemens / L&T / Hager / Crabtree Xpro. MCB / Isolator Make: Legrand-DX3 / Schneider-Acti9 / Siemens / L&T Exora / Crabtree. MCCB Make: L&T- D shine / Schneider-NS NSX/Legrand -DP X3/ Siemens-3VL / Hager- h3/C&S -Winbreak.

6

-

285276

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and fixing of 4 Way VTPN DB with IP 43 Protection as per IS:13032 with 1 No., of 125A 4P MCCB, Adjustable, Confirms to IS/IEC 60947-2 having Breaking Capacity 25 KA with thermal magnetic release Panel Mounted as incomer with 4 Nos of 63A, 10KA, TP MCBs C Curve ISI Mark as Out goings including internal connections and labour charges for FLUSH Mounting etc., complete. DB Makes : Legrand / Schneider / Siemens / L&T / Hager / Crabtree Xpro. MCB / Isolator Make: Legrand-DX3 / Schneider-Acti9 / Siemens / L&T Exora / Crabtree. MCCB Make: L&T- D shine / Schneider-NS NSX/Legrand -DP X3/ Siemens-3VL / Hager- h3/C&S -Winbreak.

2

-

72162

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and fixing of 6 Way TPN DB Horizontal with IP 43 Protection (8+12 Moduleas)as per IS:13032 with 1 No., of 63A FP Isolator as incomer and 18 Nos 6-32 A 10kA SP MCBs as out goings including internal connections and labour charges for FLUSH Mounting etc., complete ( For Power DBs and UPS DBs ) DB Make: Legrand / Schneider / Siemens / L&T / Crabtree Xpro / ABB / C&S. MCB / Isolator Make: Legrand-DX3 / Schneider-Acti9 / Siemens / L&T Exora / Crabtree.

6

-

86388

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and fixing of 6 Way TPN DB Horizontal with IP 43 Protection (8+12 Moduleas) asper IS:13032 with 1 No of 40A FP Isolator as incomer and 18 Nos 6-32 A 10kA SP MCBs as out goings including internal connections and labour charges for FLUSH Mounting etc., complete. ( For Lighting DBs ) DB Make: Legrand / Schneider / Siemens / L&T / Crabtree Xpro / ABB / C&S. MCB / Isolator Make: Legrand-DX3 / Schneider-Acti9 / Siemens / L&T Exora / Crabtree.

5

-

71440

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and fixing of 4 Way TPN DB Horizontal with IP 43 Protection (8+12 Moduleas)as per IS:13032 with 1 No., of 63A FP Isolator as incomer and 12 Nos 6-32 A 10kA SP MCBs as out goings including internal connections and labour charges for FLUSH Mounting etc., complete (For Power DBs and UPS DBs ) DB Make: Legrand / Schneider / Siemens / L&T / Crabtree Xpro / ABB / C&S. MCB / Isolator Make: Legrand-DX3 / Schneider-Acti9 / Siemens / L&T Exora / Crabtree.

12

-

129660

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and fixing of 4 Way TPN DB Horizontal with IP 43 Protection (8+12 Moduleas) asper IS:13032 with 1 No of 40A FP Isolator as incomer and 12 Nos 6-32 A 10kA SP MCBs as out goings including internal connections and labour charges for FLUSH Mounting etc., complete. (For Lighting DBs) DB Make: Legrand / Schneider / Siemens / L&T / Crabtree Xpro / ABB / C&S. MCB / Isolator Make: Legrand-DX3 / Schneider-Acti9 / Siemens / L&T Exora / Crabtree.

6

-

64170

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and fixing of FP Metal Enclosure with IP 20 Protection DB Make with 1 No 63A, 10 KA FP MCB including internal connection and labour charges for Flush Mounting etc., complete. DB Make: Legrand / Schneider / Siemens / L&T / Crabtree Xpro / ABB / C&S. MCB / Isolator Make: Legrand-DX3 / Schneider-Acti9 / Siemens / L&T Exora / Crabtree.

8

-

29984

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and fixing of 12 Way SPN DB with IP 43 Protection as per IS:13032 and with 1 No 40A DP Isolator as Incommer and 10 Nos 10A 10KA SP MCB as out goings and for concealing in wall etc complete. DB Make: Legrand / Schneider / Siemens / L&T / Crabtree Xpro / ABB / C&S. MCB / Isolator Make: Legrand-DX3 / Schneider-Acti9 / Siemens / L&T Exora / Crabtree.

4

-

27132

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Distribution Board Supply and fixing of DP/FP Metal Enclosure with IP 20 Protection DB Make with 1 No 20A, 10 KA DP MCB including internal connection and labour charges for Flush Mounting etc.,complete. DB Make: Legrand / Schneider / Siemens / L&T / Crabtree Xpro / ABB / C&S. MCB / Isolator Make: Legrand-DX3 / Schneider-Acti9 / Siemens / L&T Exora / Crabtree.

45

-

87750

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply & run of 5 of 10.0 Sqmm (phases, neutral and earth) FRLS PVC insulated flexible copper cable in the existing conduict pipe for run of mains from Power panel board to TPN DB"s with pin type lugs and connections etc., complete. [for PDBs] Makes : Finolex / RR kabel / Havells / Beljin(HFFR)/Ollivin(HFFR) / Finecab (HFFR) / GM(HFFR) / Gold Medal(HFFR) /Million(HFFR) / KEI (HFFR) / Polycab (HFFR) / V-Guard (HFFR)./ DEC(HFFR) / Bonton (HFFR) and Avocab (HFFR) / Southking (HFFR) / Fortune Arrt (HFFR).

750

-

519000

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply & run of 5 of 6.0 Sqmm (phases, neutral and earth) FRLS PVC insulated flexible copper cable in the existing conduict pipe for run of mains from Power panel board to TPN DB"s with pin type lugs and connections etc., complete. [for LDBs] Makes : Finolex / RR kabel / Havells / Beljin(HFFR)/Ollivin(HFFR) / Finecab (HFFR) / GM(HFFR) / Gold Medal(HFFR) /Million(HFFR) / KEI (HFFR) / Polycab (HFFR) / V-Guard (HFFR)./ DEC(HFFR) / Bonton (HFFR) and Avocab (HFFR) / Southking (HFFR) / Fortune Arrt (HFFR).

500

-

231000

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and 3 runs of 6.0 sq mm (phase neutral and earth) FRLS PVC insulated flexible copper cable in existing conduit pipe including labour charges etc., complete Makes : Finolex / RR kabel / Havells / Beljin(HFFR)/Ollivin(HFFR) / Finecab (HFFR) / GM(HFFR) / Gold Medal(HFFR) /Million(HFFR) / KEI (HFFR) / Polycab (HFFR) / V-Guard (HFFR)./ DEC(HFFR) / Bonton (HFFR) and Avocab (HFFR) / Southking (HFFR) / Fortune Arrt (HFFR).

500

-

136500

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and 3 runs of 4.0 sq mm (phase neutral and earth) FRLS PVC insulated flexible copper cable in existing conduit pipe including labour charges etc., complete for 16A sockets. Makes : Finolex / RR kabel / Havells / Beljin(HFFR)/Ollivin(HFFR) / Finecab (HFFR) / GM(HFFR) / Gold Medal(HFFR) /Million(HFFR) / KEI (HFFR) / Polycab (HFFR) / V-Guard (HFFR)./ DEC(HFFR) / Bonton (HFFR) and Avocab (HFFR) / Southking (HFFR) / Fortune Arrt (HFFR).

4500

-

850500

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and run of 3 of 2.5 sq.mm ( phase neutral and earth ) FRLS PVC insulated flexible copper cable in existing conduit pipe for individual lighting circuits including labour charges etc., complete as required for switch boards. Makes : Finolex / RR kabel / Havells / Beljin(HFFR)/Ollivin(HFFR) / Finecab (HFFR) / GM(HFFR) / Gold Medal(HFFR) /Million(HFFR) / KEI (HFFR) / Polycab (HFFR) / V-Guard (HFFR)./ DEC(HFFR) / Bonton (HFFR) and Avocab (HFFR) / Southking (HFFR) / Fortune Arrt (HFFR).

3800

-

497800

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Run of Mains Supply and run of 1 of 22 /0.3mm ( 1.5 Sq.mm ) FRLS P.V.C. insulated flexible copper cable in existing conduit pipe for earth continuity including all labour charges etc., complete. Makes : Finolex / RR kabel / Havells / Beljin(HFFR)/Ollivin(HFFR) / Finecab (HFFR) / GM(HFFR) / Gold Medal(HFFR) /Million(HFFR) / KEI (HFFR) / Polycab (HFFR) / V-Guard (HFFR)./ DEC(HFFR) / Bonton (HFFR) and Avocab (HFFR) / Southking (HFFR) / Fortune Arrt (HFFR).

2000

-

64000

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and fixing of 1 No 6A and 1 No 16A ISI mark Modular type switch with 1 No 6A 3/2 pin and 1 No 16A socket wall plug sockets on suitable size Modular deep box with cover frame GI switch box fixing on separate board including all labour charges etc., complete. Makes of switches:- Legrand Arteor / Schneider Zen celo / Honeywell Blenge Plus / Cabtree Amare / Logus Platina / Gold Medal GIFA / GM-Zenova/ L&T- Englaze.

95

-

116945

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply & fixing of 16A/6A, 2 in one socket with 16A switch control modular type with and GI switch box with front cover plate including all labour charges etc., complete. Makes of switches:- Legrand Arteor / Schneider Zen celo / Honeywell Blenge Plus / Cabtree Amare / Logus Platina / Gold Medal GIFA / GM-Zenova/ L&T- Englaze.

73

-

52852

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and Fixing of 16A/6A, 2 in one, modular type power socket outlet with 16A switch (ISI marked) modular type and 3 No of 6A modular type sockets with 6A modular type (ISI marked) switch control with front cover plate on existing modular metal switch box including all labour charges, giving all connections etc., complete with following configurations 1) 16A Socket - 1 No 2) 16A Switch - 1 No 3) 6A socket - 3 No 4) 6A switch - 3 No etc complete. Makes of switches : Legrand Arteor / Schneider Zen celo / Honeywell Blenge Plus / Crabtree Amare / Logus Platina / Gold Medal GIFA / GM-Zenova/ L&T- Englaze.

148

-

338032

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and fixing of 2 Nos 6A ISI mark Modular type switch with 3Nos 6A 3/2 pin wall plug socket on suitable size Modular deep box with cover frame GI switch box fixing on separate board including all labour charges etc., complete. Makes of switches:- Legrand Arteor / Schneider Zen celo / Honeywell Blenge Plus / Cabtree Amare / Logus Platina / Gold Medal GIFA / GM-Zenova/ L&T- Englaze.

30

-

43080

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Wiring with 3 of 22/0.3mm ( 1.5 Sq.mm) FRLS / HFFR P.V.C. insulated flexible copper cable (ISI MARK) in existing pipe with 6A switch and 6A, 3/2 pin socket Modular type with 6A switch control and MS boxes with cover plate and GI switch box fixing on separate board including all labour charges etc., complete. Makes : Finolex / RR kabel / Havells / Beljin(HFFR)/Ollivin(HFFR) / Finecab (HFFR) / GM(HFFR) / Gold Medal(HFFR) /Million(HFFR) / KEI (HFFR) / Polycab (HFFR) / V-Guard (HFFR)./ DEC(HFFR) / Bonton (HFFR) and Avocab (HFFR) / Southking (HFFR) / Fortune Arrt (HFFR). Makes of switches : Legrand Arteor / Schneider Zen celo / Honeywell Blenge Plus / Crabtree Amare / Logus Platina / Gold Medal GIFA / GM-Zenova/ L&T- Englaze.

19

-

16853

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and fixing of 6A ISI Mark 3/2 pin Modular socket with 6A 1way Modular switch, 3 Module box with cover frame and GI switch box on common switch board with connections etc., complete. Makes of switches:- Legrand Arteor / Schneider Zen celo / Honeywell Blenge Plus / Cabtree Amare / Logus Platina / Gold Medal GIFA / GM-Zenova / L&T- Englaze.

161

-

92253

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Wiring with 2 runs of 22/0.3mm ( 1.5 Sq.mm) FRLS P.V.C. insulated flexible copper cable (ISI MARK) in existing pipe with 6A Modular switch, Ceiling rose/BH/SBH Modular switches with cover plate and GI switch box including all labour charges etc., complete stairecase points. ( for Non-Residential Building ). Makes : Finolex / RR kabel / Havells / Beljin(HFFR)/Ollivin(HFFR) / Finecab (HFFR) / GM(HFFR) / Gold Medal(HFFR) /Million(HFFR) / KEI (HFFR) / Polycab (HFFR) / V-Guard (HFFR)./ DEC(HFFR) / Bonton (HFFR) and Avocab (HFFR) / Southking (HFFR) / Fortune Arrt (HFFR). Makes of switches : Legrand Arteor / Schneider Zen celo / Honeywell Blenge Plus / Crabtree Amare / Logus Platina / Gold Medal GIFA / GM-Zenova/ L&T- Englaze.

3

-

3633

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Wiring Wiring with 2 runs of 22/0.3mm (1.5 Sq.mm) FRLS P.V.C. insulated flexible copper cable (ISI MARK) in existing pipe with 6A Modular switch, Ceiling rose/BH/SBH Modular switches with cover plate and GI switch box including all labour charges etc., complete. (for Non-Residential Building). Makes : Finolex / RR kabel / Havells / Beljin(HFFR)/Ollivin(HFFR) / Finecab (HFFR) / GM(HFFR) / Gold Medal(HFFR) /Million(HFFR) / KEI (HFFR) / Polycab (HFFR) / V-Guard (HFFR)./ DEC(HFFR) / Bonton (HFFR) and Avocab (HFFR) / Southking (HFFR) / Fortune Arrt (HFFR). Makes of switches : Legrand Arteor / Schneider Zen celo / Honeywell Blenge Plus / Crabtree Amare / Logus Platina / Gold Medal GIFA / GM-Zenova/ L&T- Englaze.

735

-

593145

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and fixing PVC / MS galvanished Fan hook box with hook including all Labour charges etc., complete.

183

-

26169

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and fixing of 25mm outer dia Medium grade P.V.C. pipe (ISI MARK) concealed in wall with all required PVC/MS junction boxes and all accessories including masonary work etc., complete. Makes:- Sudhakar / Finolex / Modi / VIP / Precision / Universal / Million Plast / Gold / Polycab / DEC / Beljin / Champion / Austro.

2012.25

-

177078

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;ELECTRICAL WORKS Conduit Pipe Supply and fixing of 25mm outer dia Heavy grade PVC pipe (ISI MARK) concealed in Roof Slabs with all required PVC/MS deep boxes and all accessories including and labour charges etc, complete. Makes:- Sudhakar / Finolex / Modi / VIP / Precision / Universal / Million Plast / Gold / Polycab / DEC / Beljin / Champion / Austro.

4998.75

-

409897.5

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;VALVE BOX (WITH VALVES) FOR MEDICAL USAGE Low Pressure Tube

400

-

38800

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;VALVE BOX (WITH VALVES) FOR MEDICAL USAGE High Pressure tube imported

400

-

36800

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;VALVE BOX (WITH VALVES) FOR MEDICAL USAGE Valve Box - 3 Gas Service (size 15mm X 15 mm X 22mm) with NIST Connection & S.S.Valve for O2

5

-

72450

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Bed Head Wall Panel Horizontal SITC of Electrical Control panel should be automatic change over panel for changeover from A to B and then from B to A and then from B to C. If any pump trips then the second should start automatically. The panel should consist of contactors Amp meter, Volt meter, Single phase protector, MCB, phase indicator, compressor on ?off trip indicator and pressure switch .

1

-

303450

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Bed Head Wall Panel Horizontal Bed Head Panel : The bed Head Panel should have provision for Medical Gas outlet points as per requirement and Nurse call systems.it should be equpped with electrical switch, socket of 16 Amp, socket for 2+2

80

-

565520

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;ACCESSORIES Supply and fixing of BPC Flow meter with Humidifier bottle and probe near out let point, flow meter body made of brass material and should be back pressure compensated suitable for accurate gas flow measurement and control within a range of 0-15 litres per minute, flow tube and components should be mae of clear impact resistant polycarbonate and Humidifier shuld have built in safety valve and should be made of unbreakable polycarbonate material and autoclavable at 134 degrees centigrade, including cost and conveyance of materials, errection chages, commissioning charges etc. for finished item of work

80

-

108000

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;ACCESSORIES Oxygen outlets (Indeginous) with Probes as per DIN standards.

80

-

150000

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;DIGITAL ALARM SYSTEMS 3 Gas Microprocessor Controlled Alarm With Digital Display

5

-

125000

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Ward Vacuum Unit. Ward Vacuum Unit complete with Regulator , collection bottle, Adapter and Bracket for collection bottle

80

-

137120

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Medical Air outlets (Indeginous) - with Probes as per DIN standards

80

-

150000

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;OUTLETS FOR AIR & VACUUM Vacuum outlets (Indeginous) - with Probes as per DIN standards

80

-

150000

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and fixing of 54 mm dia. Isolation Valves with necessary end fittings designed for a working pressure of 300 psi / 27 inc. Hg. Vaccum/Oxygen, Non Ferrous, Non Lubricated with 90 degrees turn, Hand lever operated of standard make of valves including cost and conveyance of all mateials, taxes, transportation chrges, fixing charges and testing charges and all labour charges etc. comlete for finished item of work.54 mm Valves

3

-

15000

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and fixing of 28 mm dia. Isolation Valves with necessary end fittings designed for a working pressure of 300 psi / 27 inc. Hg. Vaccum/Oxygen, Non Ferrous, Non Lubricated with 90 degrees turn, Hand lever operated of standard make of valves including cost and conveyance of all mateials, taxes, transportation chrges, fixing charges and testing charges and all labour charges etc. comlete for finished item of work. 28 mm Valves

10

-

32750

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and fixing of 22 mm dia. Isolation Valves with necessary end fittings designed for a working pressure of 300 psi / 27 inc. Hg. Vaccum/Oxygen, Non Ferrous, Non Lubricated with 90 degrees turn, Hand lever operated of standard make of valves including cost and conveyance of all mateials, taxes, transportation chrges, fixing charges and testing charges and all labour charges etc. comlete for finished item of work. 22 mm Valves

10

-

20500

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Isolation Valves Supply and fixing of 15 mm dia. Isolation Valves with necessary end fittings designed for a working pressure of 300 psi / 27 inc. Hg. Vaccum/Oxygen, Non Ferrous, Non Lubricated with 90 degrees turn, Hand lever operated of standard make of valves including cost and conveyance of all mateials, taxes, transportation chrges, fixing charges and testing charges and all labour charges etc. comlete for finished item of work.15 mm Valves

50

-

72500

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and fixing of Medical grade Copper Pipe Lines of 54mm dia. 1.2mm thick for distribution, pipes shall be Solid drawn, seamless, deoxidezed, non-arsenical, half hard, tempered and degreased copper pipeconforming to EN 13348. All copper pipes should be degreased & delivered capped at both ends. The pipes should be accompanied with manufactureres test certificate for the physical properties & chemical composition. Copper pipe should also have third party inspection certificate from Lloyds' Register services including cost and conveyance of pipes, cost of necessary specials made of copper and suitable for a steam working pressure of 17 bar and should confirm to BS 864 with specially made for brazed socket type connections, including taxes, transportation charges including laying and jointing, testing, commissioning and all other labour charges etc. complete for finished item of work.(54mm O.D x 1.2mm thick copper pipe)

50

-

126000

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and fixing of Medical grade Copper Pipe Lines of 42 mm dia. 1.2mm thick for distribution, pipes shall be Solid drawn, seamless, deoxidezed, non-arsenical, half hard, tempered and degreased copper pipeconforming to EN 13348. All copper pipes should be degreased & delivered capped at both ends. The pipes should be accompanied with manufactureres test certificate for the physical properties & chemical composition. Copper pipe should also have third party inspection certificate from Lloyds' Register services including cost and conveyance of pipes, cost of necessary specials made of copper and suitable for a steam working pressure of 17 bar and should confirm to BS 864 with specially made for brazed socket type connections, including taxes, transportation charges including laying and jointing, testing, commissioning and all other labour charges etc. complete for finished item of work.(42mm O.D x 1.2mm thick copper pipe)

40

-

71720

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and fixing of Medical grade Copper Pipe Lines of 28 mm dia. 0.9 mm thick for distribution, pipes shall be Solid drawn, seamless, deoxidezed, non-arsenical, half hard, tempered and degreased copper pipeconforming to EN 13348. All copper pipes should be degreased & delivered capped at both ends. The pipes should be accompanied with manufactureres test certificate for the physical properties & chemical composition. Copper pipe should also have third party inspection certificate from Lloyds' Register services including cost and conveyance of pipes, cost of necessary specials made of copper and suitable for a steam working pressure of 17 bar and should confirm to BS 864 with specially made for brazed socket type connections, including taxes, transportation charges including laying and jointing, testing, commissioning and all other labour charges etc. complete for finished item of work. (28mm O.D x 0.90mm thick copper pipe)

50

-

55100

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and fixing of Medical grade Copper Pipe Lines of 22 mm dia. 0.9 mm thick for distribution, pipes shall be Solid drawn, seamless, deoxidezed, non-arsenical, half hard, tempered and degreased copper pipeconforming to EN 13348. All copper pipes should be degreased & delivered capped at both ends. The pipes should be accompanied with manufactureres test certificate for the physical properties & chemical composition. Copper pipe should also have third party inspection certificate from Lloyds' Register services including cost and conveyance of pipes, cost of necessary specials made of copper and suitable for a steam working pressure of 17 bar and should confirm to BS 864 with specially made for brazed socket type connections, including taxes, transportation charges including laying and jointing, testing, commissioning and all other labour charges etc. complete for finished item of work (22mm O.D x 0.90mm thick copper pipe)

60

-

53460

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and fixing of Medical grade Copper Pipe Lines of 15 mm dia. 0.9 mm thick for distribution, pipes shall be Solid drawn, seamless, deoxidezed, non-arsenical, half hard, tempered and degreased copper pipeconforming to EN 13348. All copper pipes should be degreased & delivered capped at both ends. The pipes should be accompanied with manufactureres test certificate for the physical properties & chemical composition. Copper pipe should also have third party inspection certificate from Lloyds' Register services including cost and conveyance of pipes, cost of necessary specials made of copper and suitable for a steam working pressure of 17 bar and should confirm to BS 864 with specially made for brazed socket type connections, including taxes, transportation charges including laying and jointing, testing, commissioning and all other labour charges etc. complete for finished item of work. (15mm O.D x 0.90mm thick copper pipe)

120

-

73920

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and fixing of Copper Pipe Lines Supply and fixing of Medical grade Copper Pipe Lines of 12 mm dia. 0.7 mm thick for distribution, pipes shall be Solid drawn, seamless, deoxidezed, non-arsenical, half hard, tempered and degreased copper pipeconforming to EN 13348. All copper pipes should be degreased & delivered capped at both ends. The pipes should be accompanied with manufactureres test certificate for the physical properties & chemical composition. Copper pipe should also have third party inspection certificate from Lloyds' Register services including cost and conveyance of pipes, cost of necessary specials made of copper and suitable for a steam working pressure of 17 bar and should confirm to BS 864 with specially made for brazed socket type connections, including taxes, transportation charges including laying and jointing, testing, commissioning and all other labour charges etc. complete for finished item of work. (12mm O.D x 0.7 mm thick copper pipe)

200

-

96000

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;NITROUS OXIDE SYSTEM 2 x 4 Main Nitrous Oxide Manifold with 19 mm O.D x12 mm ID Copper Pipe mounted on Top Frame, Middle Frame and Bottom Frame, along with brass blocks,NRVs/Cylinder Valves and Pigtail Pipes of 1 mtr long of size 8 mm O.D x 3 mm I.D,duly tested at 250 Kg/Cm2 pressure. & Semi Automatic Control Panel for Nitrous Oxide.

1

-

45300

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;2 x 4 Oxygen Emergency Manifold with 19 mm O.D x12 mm ID Copper Pipe mounted on Top Frame with brass blocks,NRVs/Cylinder Valves and Pigtail Pipes of 1 mtr long of size 8 mm O.D x 3 mm I.D, duly tested at 250 Kg/Cm2 pressure with Single stage high flow / Double stage Regulator.

1

-

45300

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;OXYGEN SYSTEM 2 x 20 Oxygen Main Manifold with 19 mm O.D x12 mm ID Copper Pipe mounted on Top Frame with brass blocks, NRVs/Cylinder Valves and Pigtail Pipes of 1 mtr long of size 8 mm O.D x 3 mm I.D,duly tested at 250 Kg/Cm2 pressure. & Fully Automatic Control Panel for Oxygen.

1

-

310900

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supplying,laying,jointing of Single Socket Solfit Pipe SN 8 (6Mtr) (for Underground) pipe of Ashirvad make of Conforming to ISI including excavation of trenches and socket pits in any soil (except rock requiring blasting) and refilling with watering and tamping to the required slope including cost and conveyance of all materials to site and all labour charges , overheads & contractor profit etc., complete for finished item of work

30

-

117990

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supplying,laying,jointing of Single Socket Solfit Pipe SN 8 (6Mtr) (for Underground) pipe of Ashirvad make of Conforming to ISI including excavation of trenches and socket pits in any soil (except rock requiring blasting) and refilling with watering and tamping to the required slope including cost and conveyance of all materials to site and all labour charges , overheads & contractor profit etc., complete for finished item of work

10

-

11180

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supplying,laying,jointing of Single Socket Solfit Pipe SN 8 (6Mtr) (for Underground) pipe of Ashirvad make of Conforming to ISI including excavation of trenches and socket pits in any soil (except rock requiring blasting) and refilling with watering and tamping to the required slope including cost and conveyance of all materials to site and all labour charges , overheads & contractor profit etc., complete for finished item of work

10

-

5580

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supplying & Fixing Indian make white glazed vitreous china porcelain sink conforming to IS:2556-Part-5-1994 on cantilever brackets with waste fittings like rubber plug, chain,32 mm nominal size C.P. Fitting with parallel pipe thread conforming to IS:2963-1979 : 750 x 450 x 250of Ist quality ncluding chiselling brick masonry wall and making good & restoring to original surfaces overheads & contractors profit complete.for finished item of work in all floors.

20

-

106440

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supplying and fixing of stainless steel sink of size 508.00mm x 457.2mm x 203.20mm, 1mm thick of Indian make fixed on cantilever brackets including supply and fixing 31.75mm C.P. waste coupling, 30mm dia PVC flexible waste pipe of 914.4 mm length of Ist quality ncluding chiselling brick masonry wall and making good & restoring to original surfaces , overheads & contractors profit complete for finished item of work in all floors

12

-

63804

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Construction of brick masonry support for GI pipe of size 304.80mm x 228.60mm x 228.60 mm in CM (1:8) prop including plastering and finishing with 12mm thick in CM (1:5) including cost and conveyance of all materials and all labour charges, overheads & contractors profit complete for finished item of work for all floors.

250

-

24500

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supplying and fixing of SWR PVC pipes (Prince/ Sudhakar/ Kisan/ Supreme or any ISI brand) 4 Kg/Sq.cm. and fixing all special such as plain bends, off sets, door bends, single junctions, double junctions as per site requirement, fixing with PVC clamps if necessary with required number of Bombay nails including cost and conveyance of all materials to site, labour charges, overheads & contractors profit complete for finished item of work at all floor levels. (APSS No. 1302 1319 & 1326)

380

-

234460

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supplying and fixing of SWR PVC pipes (Prince/ Sudhakar/ Kisan/ Supreme or any ISI brand) 4 Kg/Sq.cm. and fixing all special such as plain bends, off sets, door bends, single junctions, double junctions as per site requirement, fixing with PVC clamps if necessary with required number of Bombay nails including cost and conveyance of all materials to site, labour charges, overheads & contractors profit complete for finished item of work at all floor levels. (APSS No. 1302 1319 & 1326)

600

-

198600

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supplying and fixing of SWR PVC pipes (Prince/ Sudhakar/ Kisan/ Supreme or any ISI brand) 4 Kg/Sq.cm. and fixing all special such as plain bends, off sets, door bends, single junctions, double junctions as per site requirement, fixing with PVC clamps if necessary with required number of Bombay nails including cost and conveyance of all materials to site, labour charges, overheads & contractors profit complete for finished item of work at all floor levels. (APSS No. 1302 1319 & 1326)

390

-

116220

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supplying and fixing Bronze Gate/ Globe valve as per IS - 778 Class - I, Indian make heavy type including cost and conveyance of all materials , labour charges , overheads & contractors profit complete for finished item of work.

10

-

42860

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supplying and fixing Bronze Gate/ Globe valve as per IS - 778 Class - I, Indian make heavy type including cost and conveyance of all materials , labour charges , overheads & contractors profit complete for finished item of work.

10

-

29220

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supplying and fixing Bronze Gate/ Globe valve as per IS - 778 Class - I, Indian make heavy type including cost and conveyance of all materials , labour charges , overheads & contractors profit complete for finished item of work.

18

-

39006

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supplying and fixing Bronze Gate/ Globe valve as per IS - 778 Class - I, Indian make heavy type including cost and conveyance of all materials , labour charges , overheads & contractors profit complete for finished item of work.

40

-

57000

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and fixing of Ashirvad/ Ajay/ Astral Flowguard or equivalent CPVC Pipes and Fittings SDR 11 to meet the requirement of ASTM-D 2846 and are produced in CTS (Copper Tube Sizes 1/2" to 2") for hot and cold water (IS 15778:2007) including cost and conveyance of all materials to site, labour charges for fixing, overheads & contractors profit complete for finished item of work at all floor levels.

250

-

161500

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and fixing of Ashirvad/ Ajay/ Astral Flowguard or equivalent CPVC Pipes and Fittings SDR 11 to meet the requirement of ASTM-D 2846 and are produced in CTS (Copper Tube Sizes 1/2" to 2") for hot and cold water (IS 15778:2007) including cost and conveyance of all materials to site, labour charges for fixing, overheads & contractors profit complete for finished item of work at all floor levels.

120

-

53280

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and fixing of Ashirvad/ Ajay/ Astral Flowguard or equivalent CPVC Pipes and Fittings SDR 11 to meet the requirement of ASTM-D 2846 and are produced in CTS (Copper Tube Sizes 1/2" to 2") for hot and cold water (IS 15778:2007) including cost and conveyance of all materials to site, labour charges for fixing, overheads & contractors profit complete for finished item of work at all floor levels.

220

-

78760

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and fixing of Ashirvad/ Ajay/ Astral Flowguard or equivalent CPVC Pipes and Fittings SDR 11 to meet the requirement of ASTM-D 2846 and are produced in CTS (Copper Tube Sizes 1/2" to 2") for hot and cold water (IS 15778:2007) including cost and conveyance of all materials to site, labour charges for fixing, overheads & contractors profit complete for finished item of work at all floor levels.

300

-

78600

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and fixing of Ashirvad/ Ajay/ Astral Flowguard or equivalent CPVC Pipes and Fittings SDR 11 to meet the requirement of ASTM-D 2846 and are produced in CTS (Copper Tube Sizes 1/2" to 2") for hot and cold water (IS 15778:2007) including cost and conveyance of all materials to site, labour charges for fixing, overheads & contractors profit complete for finished item of work at all floor levels.

350

-

76650

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supplying and fixing white glazed flat back Bowl urinals of size 440 mm x 265 mm x 315 mm with integral flushing rim fixed with screws complete Indian make (HSW/Parry/Neycer) conforming to IS:2556-1995 as approved by Engineer-in-charge, including supply and fixing 12.7mm PVC connection with brass plumber union nuts CP coated, 12.70mm push cock 1st quality of approved make , 30mm dia PVC flexible waste pipe of 914.4 mm length of Ist quality including cost and conveyance of all materials to site, labour charges , overheads & contractors profit complete for finished item of work for all floors.

20

-

33240

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supplying and fixing Chromium plated finish brass body quarter turn Bibcock cum Health Faucet with 1m long tube and wall hook with 7 - 10 years warranty with necessary fittings etc., complete including cost and conveyance of all materials, labour charges, overheads & contractor profit complete for finished item of work in all floors.

41

-

152725

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supplying and fixing 15 mm brass body CP finish bib tap of not less than 300 grams weight screw type (full turn) with internal / external threaded connection conforming to IS 8931 as approved by the Engineer-In-Charge including cost and conveyance of all materials, labour charges , overheads & contractors profit complete for finished item of work in all floors.

130

-

38740

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supplying and fixing of 25.4mm dia, 609.6mm long aluminium anodized towel rods with brackets and aluminium screws including cost and conveyance of all materials, labour charges , overheads & contractors profit for finished item of work.

59

-

11269

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supplying and fixing TV shape mirror with plastic frame of size 609.6mm x 457.2mm , plywood back with NP screws 1st quality including cost and conveyance of all materials, labour charges , overheads & contractors profit for finished item of work in all floors.

59

-

34987

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supplying and fixing CP finish brass soap dish of approved make ISI quality including cost and conveyance of all materials, labour charges for fixing, overheads & contractors profit for finished item of work in all floors

59

-

40179

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supplying and fixing Indian make Flat Back Wash Hand Basin 1st quality conforming to IS:2556-Part-4:1972 of size 550mm x 400mm with 32 mm nominal size C.P. Fitting with parallel pipe thread conforming to IS:2963-1979 and fitted with 15 mm nominal bore Chromium Plated Pillar Tap of 1st quality Indian make heavy duty complete with standard CI brackets including wooden blocks ,1 No.12.70mm PVC connection with brass union nuts CP coated , angle stop cock 12.70mm dia. first quality Indian make heavy duty, 30mm dia. PVC flexible waste pipe 914.4mm length of 1st quality including cost and conveyance of all materials to site, labour charges , overheads & contractors profit for finished item of work.

59

-

173873

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supplying and fixing 580mm x 440mm long Orissa pan white glazed Water Closet 1st quality ISI marked confirming to IS:2556-Part-3-1981 with "P" or "S" trap, ISI marked and providing masonry seat, CC squatting plate and 10 litres capacity single flush PVC low level cistern with internal components fixed on 2 Nos. of teak wood blocks of size 76.20mm x 101.60mm using required size of nails, screws as approved by Engineer-in-charge, 15 mm nominal size CP finish brass angled stop valve screw type with internal /external threaded conforming to IS 8931, 12.70mm PVC connection with brass union nuts CP coated , 31.75mm brass plumber union, P trap or S trap of Indian W.C. shall be encased on CC (1:2:4) 150mm alround well above the joint to stop leakage at the joint etc., complete including cost and conveyance of all materials to site, cost of CC bed, labour charges and seigniorage charges, overheads & contractors profit etc., complete for finished item of work.

10

-

53330

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supplying and fixing European Water Closet of 1st quality conforming to IS:2556-Part-2-1973 of white glazed with 'S' trap,supplying and fixing best Indian make plastic seat and lid for European water closets with rubber or plastic Buffers as per IS 2548-1996 and 10 litres capacity single flush PVC low level cistern with internal components and fixed using required size of nails and screws, 15 mm nominal size CP finish brass angled stop valve screw type with internal /external threaded conforming to IS 8931, 12mm PVC connections with brass union nuts CP coated including cost and conveyance of all materials to site, overheads & contractors profit etc., complete for finished item of work for all floors.

41

-

247394

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supplying and fixing of 4" (101.6mm) multi floor trap with jali - UPVC/SWR pipe fittings as per site requirements with standard practice for all floors including cost and conveyance of all materials to site, labour charges , overheads & contractors profit etc., complete for finished item of work.

66

-

11880

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supplying and fixing of SWG Gully traps 150mm x 100mm of ISI make confirming to IS 651 & 4127 with C.I grating & constructing cement brick masonry in CM (1:6) prop., intermediate chamber and fitted with 304.8 mm X 288.6 mm (12"x9") C.I Frame with hinged cover of standard make as approved including cost and conveyance of all materials to site, labour charges, overheads & contractors profit etc., complete for finished item of work.

66

-

48972

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Constructing 457.2 mm x 457.2 mm (1'6"x1'6") brick in CM 1:6 prop. Masonry. Inspection chamber upto 914.4 mm (3'0") and fitted with light weight 457.2 mm x 457.2 mm (1'6"x1'6") C.I frame and cover of 20 Kg including cost and conveyance of all materials like cement, sand, bricks, water etc., to site, cost of seigniorage charges on all materials and all incidental and operational, labour charges like mixing cement mortar, constructing masonry, lift charges, curing , overheads & contractors profit etc., complete for finished item of work as per Standard specification.

25

-

121375

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Constructing 904.0 mm (3?0?) dia brick masonry inspection chamber as per IS - 4111: Part-1:1986 with cement mortar (1:6) prop using 2nd Class Clay Bricks of 225 mm thick from approved source having a minimum crushing strength of 5 N/sq.mm including plastering with cement mortar 1:3 prop; ½? thick both inside and outside fitted with 20? dia RCC manhole covers and frames including excavating pits up to a depth of 1524 mm (5'-0") in all sorts of soils (exculding rock) and laying cement conrete (1:4:8) 150 mm thick using 40 mm HBG Metal and P.C.C. 1:2:4 benching and channel 100 mm thick as per Standard specification and including cost and conveyance of all materials like cement, sand, bricks, water etc., to site, cost of seigniorage charges on all materials and all incidental and operational, labour charges like mixing cement mortar, constructing masonry, lift charges, curing , overheads & contractors profit etc., complete for finished item of work as per Standard specification.

18

-

255816

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Constructing 904.0 mm (3?0?) dia brick masonry inspection chamber as per IS - 4111: Part-1:1986 with cement mortar (1:6) prop using 2nd Class Clay Bricks of 225 mm thick from approved source having a minimum crushing strength of 5 N/sq.mm including plastering with cement mortar 1:3 prop; ½? thick both inside and outside fitted with 20? dia RCC manhole covers and frames including excavating pits up to a depth of 904 mm (3'-0") in all sorts of soils (exculding rock) and laying cement conrete (1:4:8) 150 mm thick using 40 mm HBG Metal and P.C.C. 1:2:4 benching and channel 100 mm thick as per Standard specification and including cost and conveyance of all materials like cement, sand, bricks, water etc., to site, cost of seigniorage charges on all materials and all incidental and operational, labour charges like mixing cement mortar, constructing masonry, lift charges, curing , overheads & contractors profit etc., complete for finished item of work as per Standard specification.

35

-

311570

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supplying and laying, filling, jointing and testing SWG SP-1 pipe conforming to ISI 651 & 4127 with air tight Cement joints in CM (1.5:1) prop. including excavation of trenches and socket pits in any soil (except rock requiring blasting) and refilling with watering and tamping to the required slope including cost and conveyance of all materials to site and all labour charges , overheads & contractor profit etc., complete for finished item of work (APSS NO 1301 & 1318).

420

-

905520

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supplying and laying, filling, jointing and testing SWG SP-1 pipe conforming to ISI 651 & 4127 with air tight Cement joints in CM (1.5:1) prop. including excavation of trenches and socket pits in any soil (except rock requiring blasting) and refilling with watering and tamping to the required slope including cost and conveyance of all materials to site and all labour charges , overheads & contractor profit etc., complete for finished item of work (APSS NO 1301 & 1318).

11

-

123640

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;WATER SUPPLY AND SANITARY ARRANGEMENTS Supplying and laying, filling, jointing and testing SWG SP-1 pipe conforming to ISI 651 & 4127 with air tight Cement joints in CM (1.5:1) prop. including excavation of trenches and socket pits in any soil (except rock requiring blasting) and refilling with watering and tamping to the required slope including cost and conveyance of all materials to site and all labour charges , overheads & contractor profit etc., complete for finished item of work (APSS NO 1301 & 1318).

150

-

135450

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and delivery of encapsulated plastic steps manufactured as per companies standard specification including cost of materials packing as per companiess standards, loading, transportation, unloading and stacking at site of work, and taxes such as complete sales tax,C.E.D and others etc., as applicable including labour charges for fixing etc. complete for finished item of work.

30

-

6660

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supplying and fixing of Pre-painted Galvalume Trapezoidal Profile Roofing sheets with 0.50mm thickness, Coating: Alu-Zinc coating AZ150 GSM. Tensile Strength: 550 MPA. Paint coating: Regular Modified Polyester painting. Painting Thickness (Top): 18 to 20 Microns, (Bottom): 5 to 7 Microns. Sheet Width: 1.020, Length: Maximum 12 Meters with Regular Range Colours fixed with G.I ?J? bolts & nuts 8 mm dia with bitumen & G.I limpet washers filled with white lead & including a coat of approved steel primer and two coats of approved paint on over lapping of sheets complete (up to a pitch of 600) etc., complete, excluding the cost of purlins, rafters, trusses including cost and conveyance of all materials, labour charges , overheads and contractors profit etc., complete for finished item of work in all floors.

57

-

43377

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply & fixing of Rolling shutter made of 80 x 1.25 mm machine rolled CRCA laths, interlocked together through their entire length and jointed together at the ends by end-locks, mounted on specially designed pipe shaft of 50mm dia nominal bore MS B class pipe with brackets, plates, guide channels, stoppers, bottom locking plates and arrangements for inside & outside locking with push-pull operations including cost of hood cover and springs complete, painted with one coat of approved steel primer, locks, ball bearings, all accessories etc., overheads & contractors profit complete for finished item of work as per special spn: 1108

16

-

75648

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supplying & fixing collapsible steel shutters with vertical, double channel of 20 x10x2 mm of 100 mm centre ,Bracers with flat iron 40x40x6 mm with 38 mm dia steel pulleys, the top, bottom and side vertical frames of the collapsible gate with 65x65mmx8mm MS Angle and middle guide rail at site height with 65mmx8mm MS flat for the pulleys to guide and fixed with necessary hold fasts, bolts, nuts, rivets, locking arrangements, stoppers, handles, all accessories all fixtures and painted with one coat of approved steel primer etc., overheads & contractors profit complete for finished item of work as per special spn 1105

9

-

37224

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Painting two coats with synthetic enamel paint Gr-I ( Asian/Berger/Nerolac/Indocem) to new iron work including cost and conveyance of all materials to site, sales & other taxes, incidental, operational and all labour charges etc.,and overheads & contractors profit complete for finished item of work. (SS No. 1201, 1212 & 1207).

117

-

12519

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supplying and fabricating, erecting and fixing in position tabular trusses of approved design with M.S tube conforming to I.S-1161 specifications including roof frame work consisting of rafters,ties struts and purlins including cost of foundations bolts, cleats, bearings plates,etc.,complete as per the sketch enclosed and including cost of primary coat with red oxide paint including cost and conveyance of all materials, labour charges for erecting & fixing all structural steel works erecting in position and fixing by using chain pulley blocks, Derek pole arrangements and cranes etc., complete in position, labour charges for fabrication, all incidental charges, overheads and contractor profit etc., complete for finished item of work as directed by the Engineer-in-Charge

3006

-

417834

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Roofing with UV resistant multi-wall polycarbonate sheets of any colour 6mm thick fixed with Aluminium universal glazing set 40 mm wide and as per drawing etc., complete, excluding the cost of purlins, rafters, trusses, aluminium universal glazing set 40mm wide including cost and conveyance of all materials, labour charges, overheads and contractors profit etc., complete for finished item of work in all floors.

210

-

319620

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Providing and fixing of 24 gauge alluminium sheet over expansion joint groove of width 15cm fixed to walls / columns at one edge and resting over the other block walls/columns concealing expansion joint with slotted holes for free edge of aluminium sheet to facilitate free movement of aluminium sheet over the finished surface of expansion joint and wall face using sheet metal screws with nylon receiver complete including cost and conveyance of all materials to site, all incidental, operational, labour charges , overheads & contractors profit etc., complete for finished item of work as per approved drawing (for all floors for vertical joints and bottom of slab).

36

-

3024

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Providing specialized polysulphide sealant treatment to the expansion joints (Size : 25mm x 12mm) including cost and conveyance of all materials to site, all incidental, operational, labour charges etc.overheads & contractors profit complete for finished item of work as per approved drawing for all floors duly a]. Chipping and removing of existing covering on expansion joints b]. Cleaning of the surface from dirt, dust and other contaminations c].Application of one coat of - High performance specially designed SBR latex polymer based bonding agent d]. Providing and application of Acrylic Polymer modified instatement concrete /mortar to the damaged edges of joint and making the groove. e]. Providing and fixing of masking tape on top of the joint both sides f]. Providing and fixing of Back up support material of Backer rod to leave the depth of 12mm on the joint g]. Providing and application of one coat of polysulphide primer on inner edges of Joint. h]. Providing and application of Two part Polysulphide sealant to a width of 25mm and 12mm depth with putty knife and neat finish i]. Removing of masking tape and providing and application of two coats of Acrylic elastomeric cementitious coating.

36

-

29520

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Providing and fixing of Expansion joint filler board for buildings, columns, beams and slabs 25 mm thick including cost and conveyance of all materials to site, all incidental, operational, labour charges etc.overheads & contractors profit complete for finished item of work as per approved drawing for all floors.

34

-

14858

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Cladding to internal walls with 8mm thick mirror polished granite tiles length equal to flooring tiles, set over base coat of CM(1:5) 12 mm thick using screened sand with cement slurry of honey like consistency spread at the rate of 3.30 kgs per sqm and jointing with white cement paste mixed with pigment of matching shade to full depth, including cost of all materials like tiles, cement, sand and water etc., and overheads & contractors profit complete for finished item of work.(APSS No.701 &707)

32

-

63360

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;RCM facia 50mm thick in CM(1:3) using screened sand for drop walls, fins with rabbit wire mesh & nomianl reinforcement as directred by Engineer - In - Charge with dubara sponge finishing,including cost and conveyance of all materials to site, operationals &incidental,cost and conveyance of cement, wire mesh, water to work site, centering, scaffolding and form work, lift charges etc., and overheads & contractors profit complete for finished item of work but excluding cost of steel and its fabrication charges for finished item of work (APSS NO.403&903) Third floor

37

-

110482

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;RCM facia 50mm thick in CM(1:3) using screened sand for drop walls, fins with rabbit wire mesh & nomianl reinforcement as directred by Engineer - In - Charge with dubara sponge finishing,including cost and conveyance of all materials to site, operationals &incidental,cost and conveyance of cement, wire mesh, water to work site, centering, scaffolding and form work, lift charges etc., and overheads & contractors profit complete for finished item of work but excluding cost of steel and its fabrication charges for finished item of work (APSS NO.403&903) Second floor

70

-

199150

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;RCM facia 50mm thick in CM(1:3) using screened sand for drop walls, fins with rabbit wire mesh & nomianl reinforcement as directred by Engineer - In - Charge with dubara sponge finishing,including cost and conveyance of all materials to site, operationals &incidental,cost and conveyance of cement, wire mesh, water to work site, centering, scaffolding and form work, lift charges etc., and overheads & contractors profit complete for finished item of work but excluding cost of steel and its fabrication charges for finished item of work (APSS NO.403&903) First floor

26

-

70304

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supplying and fixing of stainless steel (grade 304) Wall hand railing as per approved drawing with top rail of 50mm dia pipe and 2mm thick medium class and vertical posts of 25mm dia and 1.6mm thick medium class 1 Nos for each step fixed with base plate of 75mm dia using bonding agent and anchor fastner and welding, drilling of 20mm dia holes with pneumatic compressor for fixing railing, buffing, polishing all members of the railing thouroughly, lacquer finishing to present seamless finish including cost and conveyance of all materials, electrodes, welding charges, cost of all consumables, labour charges, overheads & contractors profit etc., complete for finished item of work. Around Courtyards & Corridors.

59

-

108560

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supplying and fixing of stainless steel (grade 304) hand railing as per approved drawing with top rail of 50mm dia pipe and 2mm thick medium class and vertical posts of 25mm dia and 1.6mm thick medium class 2 Nos for each step fixed with base plate of 75mm dia using bonding agent and anchor fastner and welding, drilling of 25mm dia holes with pneumatic compressor for fixing railing, buffing, polishing all members of the railing thouroughly, lacquer finishing to present seamless finish including cost and conveyance of all materials, electrodes, welding charges, cost of all consumables, labour charges, overheads & contractors profit etc., complete for finished item of work.

71

-

400653

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and fixing of Cement Bonded Prelaminated Particle Board aluminum glazed partitions using 10mm Cement Bonded Prelaminated Particle Board and 5.00mm thick plain glass to full height. Using with Cement Bonded Prelaminated Particle Board to a height of 0.91 meter at bottom panel and remaining height with glass and aluminum sections anodized to 12 to 15 microns and of sections of size 37mm x 62mm and 1.5mm thickness with one meter centre to centre duly fixed with clip beading on both sides including fixing the frame to pillars by M.S. flats, bolts and nuts including cost and conveyance of all materials etc., complete as directed during execution including overheads & contractors profit etc., complete for finished item of work.

183

-

775920

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and fixing of curtain Glazing made of pre painted steel (base steel as per IS 513 of 0.6 mm thick D quality, galvanized as per IS 277 with Zinc of 120 GSM) Primer coated with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12- 16 microns thick and back coated with 5-7 microns thick alkyd backer. Section for outer frame should be 46 x 52 mm, section for mullion should be 46 x 70 mm and section for beading should be 18 x 25 mm. The Glazing should be paneled with 5 mm thick plain float Glass with Ethyl Propylene diameine Monomer (EPDM) Gaskets. The sections are to be cut to length, mitre joined with corner bracket. Centre mullions are to be fixed suing mullion cap. Handle made of high grade Aluminium powder coated and nylon receiver. Gaskets made of Ethyl propylene Diamine Monomer (EPDM) Corner brackets made of CRCA with zinc phosphating. Mullion caps made of Glass filled nylon. The above frames should be fixed to the concrete / masonry wall be means of self expanding screws,overheads & contractor profit etc., complete for finished item in all floors. Fixed Glazing 2'-0" x 2'-0" (609.6x609.6mm) and 2'-0" x 3'-0" (609.6x914.4mm) grid outer frames section size of 46 x 52mm

13

-

94731

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supplying and fixing 50mm dia nominal bore Medium Grade properties & weight as per IS 1239 ISI mark MS Tube for fixing of GI Sheet including cost and conveyance of all materials to work site and all operational, incidental, labour charges , overheads & contractors profit for finished item of work.etc., complete for finished item of work in all floors for stair case head room roof.

45

-

27405

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Painting two coats with synthetic enamel paint Grade-II VOC (Volatile Organic Compound) content less than 50 grams/litre over primer coat of red oxide to new iron work including cost and conveyance of all materials to site, sales & other taxes, incidental, operational and all labour charges etc., and overheads & contractors profit complete for finished item of work in all floors. (SS No. 1201, 1212 & 1207).

64

-

10880

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Painting to new wood work and flush shutters with lappam finish, over a primary coat and painting two coats of synthetic enamel paint Grade-II VOC (Volatile Organic Compound) content less than 50 grams/litre of approved shade including cost and conveyance of all materials to site cost of primer coat and all labour charges etc. complete including applying sand paper on lappam coats for neat finish including sales & other taxes on cost of all materials etc., and overheads & contractors profit complete in all floors (APSS No.1200, 1207 & 1211).

53

-

10547

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Providing and applying Exterior grade Texture ready mixed paint with sand texture added sand particles Acrylic copolymers and mineral compounds, bactericides and various additives of average 2 to 3 mm thickness over plastered surface to prepare the surface even and smooth after thoroughly brushing the surface to remove all dirt and remains of loose powdered materials, applying emery paper, Sand the surface, clean & wipe off loose dust, applying putty/ texture paint filler by putty knife / muslin pad, air dry for 2 - 3 hrs for the surface preparation including cost and conveyance of all materials to work site and all operational, incidental, labour charges, scaffolding charges, overheads and contractors profit etc., complete for finished item of work in all floors for external walls.

296

-

87320

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Providing and applying Wall putty of White Cement or Polymer or Cement based of average 1 to 2 mm thickness over plastered surface to prepare the surface even and smooth after thoroughly brushing the surface to remove all dirt and remains of loose powdered materials, applying emery paper, Sand the surface, clean & wipe off loose dust, applying knifing paste filler by putty knife / muslin pad, air dry for 2 - 3 hrs, sand with 180 and 320 No., emery paper for the surface preparation including cost and conveyance of all materials to work site and all operational, incidental, labour charges, over heads and contractors profit etc., complete for finished item of work in all floors for Internal walls.All Floors

6255

-

1407375

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply & application of one coat water based cement primer of exterior grade II and two coats of acrylic emulsion paint exterior grade with silicon additives having VOC (Volatile Organic Compound) content less than 50 grams/ liter for exterior walls including cost and conveyance of all materials to site, sales & other taxes, incidental, operational and all labour charges etc., and overheads & contractors profit complete for finished item of work in all floors.-For External Walls

5179

-

1351719

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply & application of one coat water based cement primer of interior grade I and two coats of acrylic emulsion paint having VOC (Volatile Organic Compound) content less than 50 grams/litre for internal walls including cost and conveyance of all materials to site, sales & other taxes, incidental, operational and all labour charges etc., and overheads & contractors profit complete for finished item of work in all floors. for Internal Walls.

6935

-

1241365

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;White washing two coats with white cement to ceiling to give an even shade after thouroughly brushing the surface to remove all dirt and remains of loose powdered materials including cost of all materials, labour charges and incidental such as scaffolding, lift charges etc., and overheads & contractors profit complete for finished item of work in all floors.

4329

-

190476

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supplying and fixing of MS Grill to windows / in open court yards using 25mm x 6mm MS flat alround and 10mm MS square bars horizontally at 125mm centre to centre and vertically at 300mm centre to centre including fixing with 4 Nos of MS Z holdfasts (2 on each side) duly making cutting brick masonry, fixing and making to original surface neatly and painting grill with one coat of red oxide primer including cost all taxes and conveyance of all materials including cutting, bending, welding including all operational charges and all labour charges etc., complete for finished item of work.

378

-

478926

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Reinforced cement concrete (1:5:10) proportion (Cement: fine aggregates: coarse aggregate) using 40mm size (SS5) hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand), coarse aggregate, water etc., to site including centering using Casurina Ballies, Bamboos, Wooden Reapers, Runners, Wood Posts, Wall Plates etc., shuttering, machine mixing, laying concrete, lifting concrete manually, curing etc., and overheads & contractors profit complete as per drawings but excluding cost of steel and it's fabrication charges for finished item of work (APSS NO. 402 & 403) for Dummy columns. Fourth Floor :

27

-

322461

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supplying and fixing of Unplasticised Poly Vinyl Chloride (UPVC) casement windows openable shutters duly manufactured using UPVC reinforced profiles (Composition of profile shall consists aminimum of 5.5 PHR of TiO2 and not more than 12PHR of CaCo3 for every 100 parts of PVC resin) of 60mm x 55 mm x 2.40 mm for outer frames, 74 mm x 60mm x 2.40 mm for mullion sections for two or more openable shutters 75 mm x 60 mm x 2.40 mm for openable shutter frame capable of mounting single glazing system structurally reinforced with hot dip galvanized up to 50 microns of minimum thickness of 1.0/1.2 mm prefabricated & welded through fusion welding. The window sash shall be fitted with 5 mm thick clear float glass of reputed make duly fixed with Grey colour TPV Gasket for sash & Glazing bead shall be co-extruded with Grey colour soft PVC and accessories for casement window ? friction hinges of stainless steel grade 304/430- 2 Nos., per sash, handle with zamak alloy casting 1 No. per sash, multipoint locking system suitably concealed 1 No., per sash provided with raiser wedges for smooth operation and the system is to be installed at the site using anchor fasteners, silicon rubber sealant, easy glazing/ deglazing at site etc., including cost and conveyance of all materials, accessories, labour charges for transportation, erection at site including overheads and contractor profit etc., complete for finished item of work

28

-

239260

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and fixing of pre-painted steel top hung ventilators made of pre-painted steel as per IS 513 of-0.58 mm thick 'D quality, galvanized as per IS 277, finish painted with a polyester paint & 4 mm pinhead glass for ventilators with EPDM Gasket with handle made of high grade aluminium powder coated and nylon receiver, corner brackets made of CRCA with Zinc Phosphate, Mullion caps made of glass filled nylon, frames fixed to the concrete /masonry wall by means of self expanding screws including 10 mm square guard bars with 6 pitch complete for finished item of work including overheads & contractors profit etc., complete for finished item of work. Fixed louvers 2'-0 x 2'-0 (609.6 x 609.6mm) (Box section) outer frame section size of 33 x 56 mm and (ii) Ventilators: Fixed louvers 4'-0 x 2'-0 (1219.2 x 609.6 mm) (Box section) outer frame section size of 33 x 56 mm Mullion section size of 33 x 56 mm and (iii) Ventilators: Fixed louvers 4'-0 x 3'-0 (1219.2 x 914.4 mm) (Box section) outer frame section size of 33 x 56 mm Mullion section size of 33 x 56mm.

76

-

436392

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and fixing of pre-painted steel top hung ventilators made of pre-painted steel as per IS 513 of-0.58 mm thick 'D quality, galvanized as per IS 277, finish painted with a polyester paint & 4 mm pinhead glass for ventilators with EPDM Gasket with handle made of high grade aluminium powder coated and nylon receiver, corner brackets made of CRCA with Zinc Phosphate, Mullion caps made of glass filled nylon, frames fixed to the concrete /masonry wall by means of self expanding screws including 10 mm square guard bars with 6 pitch complete for finished item of work including overheads & contractors profit etc., complete for finished item of work. Top Hung 2 '-0 x 2'-0 (609.6x609.6mm) outer frame section size of 46mm x 52 mm shutter frame section size of 46mm x 46 mm and (ii) Ventilators: Top Hung 4 '-0 x 2'-0 (1219.2x609.6mm) outer frame section size of 46 x 52 m shutter frame section size of 46 x 46 mm Mullion section size of 46 x 70 mm and (iii) Ventilators: Top Hung 4 '-0 x 3'-0 (1219.2x914.4mm) outer frame section size of 46 x 52m m shutter frame section size of 46 x 46 mm Mullion section size of 46 x 70mm.

9

-

75546

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Providing, supplying & fixing of Fixed Louvered Ventilator made out of multi chambered uPVC sections with Glazing bead shall be co-extruded with Grey colour soft PVC. having isolated drainage and reinforced with Galvanized Iron profiles throughout the window. The outer frame having an overall size of 60 mm x 55 mm x 2.40 with reinforcement of 1 mm thickness and Mullion with overall size of 74 mm x 60 mm x 2.40 mm with reinforcement of 1 mm thickness. (Composition of profile shall consists a minimum of 5.5 PHR of TiO2 and not more than 12 PHR of CaCo3 for every 100 parts of PVC resin). Ventilator shall be provided with 4.5 mm Pin Head glass, standard hardware. Wall thickness of frame & Mullion shall be 2.4 mm., including cost and conveyance of all materials, accessories, labour charges for transportation, erection at site including overheads and contractor profit etc., complete for finished item of work

28

-

203812

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;SSupplying and fixing of Unplasticised Poly Vinyl Chloride (UPVC) 2 Track?2 Panel Sliding windows duly manufactured using UPVC reinforced profiles (Composition of profile shall consists a minimum of 5.5 PHR of TiO2 and not more than 12 PHR of CaCo3 for every 100 parts of PVC resin) of (62mm x 60 mm)/(60 mm x 45 mm) x 2.20 mm for outer frames, (66 mm x 38 mm)/(58 mm x 39 mm) x 2.20 mm for sliding shutter frames capable of mounting single glazing system, structurally reinforced with hot dip galvanized up to 50 microns of minimum thickness of 1.0/1.2 mm prefabricated & welded through fusion welding. The window sash shall be fitted with 5 mm thick clear float glass of reputed make duly fixed with Grey colour TPV Gasket for sash & Glazing bead shall be co-extruded with Grey colour soft PVC. System shall have single point locking with Touch Lock and the system is to be installed at the site using anchor fasteners, silicon rubber sealant, easy glazing/ deglazing at site etc., including cost and conveyance of all materials, accessories, labour charges for transportation, erection at site including overheads and contractors profit etc., complete for finished item of work.

100

-

774600

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supplying and fixing of Unplasticised Poly Vinyl Chloride (UPVC) 3 track sliding windows with mesh shutter ? (2-glass shutters and 1-mesh shutter) duly manufactured using UPVC reinforced profiles (Composition of profile shall consists a minimum of 5.5 PHR of TiO2 and not more than 12 PHR of CaCo3 for every 100 parts of PVC resin) of (94mm x 45 mm)/(80 mm x 52 mm) x 2.20 mm for outer frames, (58 mm x 39 mm)/(54 mm x 38 mm) x 2.20mm for sliding shutter frames capable of mounting single glazing system structurally reinforced with hot dip galvanized up to 50 microns of minimum thickness of 1.0/1.2 mm prefabricated & welded through fusion welding. The window sash shall be fitted with 5 mm thick clear float glass of reputed make and mesh shutter frame shall be (42 mm x 25mm)/(52 mm x 21.5 mm) x 2.0 mm fitted with Vinyl Coated Fiber mesh- on rollers/ pulley duly fixed with Grey colour TPV Gasket for sash & Glazing bead shall be co-extruded with Grey colour soft PVC. System shall have single point locking with Touch Lock and the system is to be installed at the site using anchor fasteners, silicon rubber sealant, easy glazing/deglazing at site etc., including cost and conveyance of all materials, accessories, labour charges for transportation, erection at site including overheads and contractors profit etc., complete for finished item of work.

299

-

2418312

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and fixing doors as per drawings with medium teak wood frame of section 100mm x 65mm and ISI marked flush door shutter of 30mm thick single shutter with bond wood solid block board type Core having cross bands and face veneers, hot pressed bonded with water proof phenol formaldehyde synthetic resin factory made conforming to IS 2202-1991 (Part-I) both sides commercial ply with internal lipping on all sides including cost and conveyance to site of medium teak wood door frame, flush shutter, including suply and fixing 6 Nos. MS Z hold fasts of size 300mm x 40mm x 5mm including ISI marked Aluminium fixtures 3 Nos. butt hinges (IS:205) of 150mm long, 1 No. aldrop (IS:2681) 250 mm long, 1 No. tower bolt (IS:204) of 150 mm x 10mm dia, 2 Nos. 125mm long handles (IS:208),1 No. rubber bush including supplying and fixing 1.20mm thick PVC sheet to full height of the shutter inside including labour charges for fixing the frame in position, fixing the shutter to the frame etc., including overheads & contractors profit complete for finished item of work as per APSS 1001 & 1002. (The vertical frame of door shall be embedded in flooring for deth of not less than 10mm) (750mm x 2100mm).

95

-

472150

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and fixing powder coated aluminium fully glazed swing door as per the approved drawing with fixed fan light of 500mm height at top door using aluminium sections of 101.60 mmm x 44.45mm , 3.18 mm thick for frame and door shutter made of styles , top and middle rail of 47.62mm x 44.45mm , 3.18 mm thick and bottom rail of 114.30mm x 44.45 mm , 3.18mm thick,powder coating of alluminium sections 25mm microns thick, 5 mm thick plain float glass fitted with suitable aluminium glazing clips and rubber beading in fan light portion, double shutters fitted with 5mm thick frosted / ground glass in the top half and 12mm thick prelaminated particle board (One side choice colour and other side balancing white lamnation) in the bottom half fitted with suitable aluminium glazing clips and rubber beading,shutters mounted on double action hydraulic floor spring of approved brand manufacture IS : 6315 marked , Hardwyn make M-3000 for doors including cost of cutting floors as required, embedding in floors and SS cover plates with brass pivot and sigle piece MS Sheet outer box with slide plate etc.complete( Weight Capacity up to 130 Kgs ) as approved by Engineer-in-Charge including supply and fixing ISI marked powder coated aluminium fixtures of 4 Nos.tower bolts 10mm bolt (IS:204) 300mm long , 4 Nos.alluminium handles (IS:208) 150mm dia and 2 Nos. aldrops (IS:2681) 300mm long including labour charges for manufacturing door , fixing the door with required No. of screws etc., including overheads & contractors profit complete for finished item of work. (The Aluminium section used shall be standard make confirming to IS 1948 ? 1961) and as approved by the Engineer) (1800mm x 2600mm).

42

-

316806

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and fixing doors as per drawings with medium teak wood frame of section 100mm x 65mm and ISI marked flush door shutter of 30mm thick single shutter with bond wood solid block board type Core having cross bands and face veneers, hot pressed bonded with water proof phenol formaldehyde synthetic resin factory made conforming to IS 2202-1991 (Part-I) both sides commercial ply with internal lipping on all sides including cost and conveyance to site of medium teak wood door frame, flush shutter, including suply and fixing 6 Nos. MS Z hold fasts of size 300mm x 40mm x 5mm including ISI marked Aluminium fixtures 3 Nos. butt hinges (IS:205) of 150mm long, 1 No. aldrop (IS:2681) 250mm long, 1 No. tower bolt (IS:204) of 150 mm x 10mm dia, 2 Nos. 125mm long handles (IS:208),1 No. rubber bush including supplying and fixing 1.20mm thick PVC sheet to full height of the shutter inside including labour charges for fixing the frame in position, fixing the shutter to the frame etc., including overheads & contractors profit complete for finished item of work as per APSS 1001 & 1002. (The vertical frame of door shall be embedded in flooring for deth of not less than 10mm) (800mm x 2100mm).

14

-

67536

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and fixing doors as per drawings with medium teak wood frame of section 100mm x 65 mm and ISI marked flush door shutters of 30 mm thick single shutter with bond wood solid block board type Core having cross bands and face veneers, hot pressed bonded with water proof phenol formaldehyde synthetic resin factory made conforming to IS 2202-1991 (Part-I) both sides commercial ply with internal lipping on all sides including cost and conveyance to site of teak wood frame, flush shutter including supply and fixing 6 Nos. MS Z hold fasts of size 300 mm x 40 mm x 5mm including cost of ISI marked Aluminium fixtures of 3 Nos. butt hinges (IS:205) 150mm long, 1 No. aldrop (IS:2681) 300mm long, 1 No. tower bolt (IS:204) of 200 mm x 10 mm dia at top, 2 Nos. 150 mm long handles (IS:208), 1 No. door stopper and 1 No. rubber bush including fixing the fixtures to door with required number of screws, bolt and nuts including labour charges for fixing the frame in position, fixing the shutter to the frame etc., including overheads & contractors profit complete for finished item of work as per APSS 1001 & 1002 (The vertical frame of door shall be embedded in flooring for a depth of not less than 10 mm) (1050mm x 2100mm).

22

-

89320

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and fixing doors as per drawings with medium teak wood frame of section 100mm x 65 mm and ISI marked flush door shutters of 30 mm thick double shutters with bond wood solid block board type Core having cross bands and face veneers, hot pressed bonded with water proof phenol formaldehyde synthetic resin factory made conforming to IS 2202-1991 (Part-I) both sides commercial ply with internal lipping on all sides including cost and conveyance to site of teak wood frame, flush shutter including supply and fixing 6 Nos. MS Z hold fasts of size 300 mm x 40 mm x 5mm including cost of ISI marked Aluminium fixtures of 6 Nos. butt hinges (IS:205) 150mm long, 1 No. aldrop (IS:2681) 300mm long, 2 Nos. tower bolts (IS:204) of 200 mm x 10 mm dia at top, 2 Nos. 150 mm long handles (IS:208), 2 Nos. door stoppers and 2 Nos. rubber bushes including fixing the fixtures to door with required number of screws, bolt and nuts including labour charges for fixing the frame in position, fixing the shutter to the frame etc., including overheads & contractors profit complete for finished item of work as per APSS 1001 & 1002 (The vertical frame of door shall be embedded in flooring for a depth of not less than 10 mm) (1200mm x 2100mm).

5

-

20680

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and fixing of doors as per approved drawings with medium teak wood frame of section 100mm x 65 mm with split type fan light of 500mm at the top fixed with 4mm thick pin headed glass using 12mm x 12mm Teak Wood beading and 2 Nos. of 10mm MS Square bars and ISI marked flush door shutter of 30mm thick single shutter with bond wood solid block board type core having cross bands and face veneers, hot pressed bonded with water proof phenol formaldehyde synthetic resin factory made conforming to IS 2202-1991 (Part-I) both sides commercial ply with internal lipping on all sides including cost and conveyance to site of teak wood frame, flush shutter including supply and fixing 6 Nos. MS Z hold fasts of size 300 mm x 40 mm x 5mm including cost of ISI marked Aluminium fixtures of 3 Nos. butt hinges (IS:205) 150mm long , 1 No. aldrop (IS:2681) 300mm long, 1 No. tower bolt (IS:204) of 200 mm x 10 mm dia at top, 2 Nos. 150mm long handles (IS:208), 1 No. door stopper and 1 No. rubber bush including fixing the fixtures to door with required number of screws, bolt and nuts including labour charges for fixing the frame in position, fixing the shutter to the frame, fixing glass in fan light portion etc, including overheads & contractors profit complete for finished item of work as per APSS 1001 & 1002 (The vertical frame of door shall be embedded in flooring for a depth of not less than 10 mm) (1000mm x 2600mm).

17

-

71757

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and fixing of doors as per approved drawings with medium teak wood frame of section 100mm x 65 mm with split type fan light of 500mm at the top fixed with 4mm thick pin headed glass using 12mm x 12mm Teak Wood beading and 2 Nos. of 10mm MS Square bars and ISI marked flush door shutter of 30mm thick double shutters with bond wood solid block board type core having cross bands and face veneers, hot pressed bonded with water proof phenol formaldehyde synthetic resin factory made conforming to IS 2202-1991 (Part-I) both sides commercial ply with internal lipping on all sides, including cost and conveyance to site of teak wood frame, flush shutter including supply and fixing 6 Nos. MS Z hold fasts of size 300 mm x 40 mm x 5mm including cost of ISI marked Aluminium fixtures of 6 Nos. butt hinges (IS:205) 150mm long, 1 No. aldrop (IS:2681) 300mm long, 2 Nos. tower bolts (IS:204) of 200 mm x 10 mm dia at top, 2 Nos. 150mm long handles (IS:208), 2 Nos. door stoppers and 2 Nos. rubber bushes including fixing the fixtures to door with required number of screws, bolt and nuts including labour charges for fixing the frame in position, fixing the shutter to the frame, fixing glass in fan light portion etc, including overheads & contractors profit complete for finished item of work as per APSS 1001 & 1002 (The vertical frame of door shall be embedded in flooring for a depth of not less than 10 mm) (1200mm x 2600mm).

165

-

693165

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and fixing of doors as per approved drawings with medium teak wood frame of section 100mm x 65 mm with split type fan light of 500mm at the top fixed with 4mm thick pin headed glass using 12mm x 12mm Teak Wood beading and 2 Nos. of 10mm MS Square bars and ISI marked flush door shutter of 30mm thick double shutters with bond wood solid block board type core having cross bands and face veneers, hot pressed bonded with water proof phenol formaldehyde synthetic resin factory made conforming to IS 2202-1991 (Part-I) both sides commercial ply with internal lipping on including cost and conveyance to site of teak wood frame, flush shutter including supply and fixing 6 Nos. MS Z hold fasts of size 300 mm x 40 mm x 5mm including cost of ISI marked Aluminium fixtures of 6 Nos. butt hinges (IS:205) 150mm long, 1 No. aldrop (IS:2681) 300mm long, 2 Nos. tower bolts (IS:204) of 200 mm x 10 mm dia at top, 2 Nos. 150mm long handles (IS:208), 2 Nos. door stoppers and 2 Nos. rubber bushes including fixing the fixtures to door with required number of screws, bolt and nuts including labour charges for fixing the frame in position, fixing the shutter to the frame, fixing glass in fan light portion etc., including overheads & contractors profit complete for finished item of work in all floors as per APSS 1001 & 1002 (The vertical frame of door shall be embedded in flooring for a depth of not less than 10 mm) (1500mm x 2600mm).

51

-

195942

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and fixing of doors as per approved drawings with medium teak wood frame of section 100mm x 65 mm with fixed fan light of 500mm at the top fixed with 4mm thick pin headed glass using 12mm x 12mm Teak Wood beading and 2 Nos. of 10mm MS Square bars and ISI marked flush door shutter of 30mm thick double shutters with bond wood solid block board type core having cross bands and face veneers, hot pressed bonded with water proof phenol formaldehyde synthetic resin factory made conforming to IS 2202-1991 (Part-I) both sides commercial ply with internal lipping on all sides including cost and conveyance to site of teak wood frame, flush shutter including supply and fixing 6 Nos. MS Z hold fasts of size 300 mm x 40 mm x 5mm including cost of ISI marked Aluminium fixtures of 6 Nos. butt hinges (IS:205) 150mm long, 1 No. aldrop (IS:2681) 300mm long, 2 Nos. tower bolts - 10mm (IS:204) of 200 mm long at top, 2 Nos. 150mm long handles (IS:208), 2 Nos. door stoppers and 2 Nos. rubber bushes including fixing the fixtures to door with required number of screws, bolt and nuts including labour charges for fixing the frame in position, fixing the shutter to the frame, fixing glass in fan light portion etc., including overheads & contractors profit complete for finished item of work as per APSS 1001 & 1002 The vertical frame of door shall be embedded in flooring for a depth of not less than 10 mm) (1800mm x 2600mm).

23

-

82846

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and fixing of doors as per approved drawings with best teak wood frame of section 100mm x 65 mm with fixed fan light of 500mm at the top fixed with 4mm thick pin headed glass using 12mmx12mm Teak Wood beading and 2 Nos. of 10mm MS Square bars and ISI marked flush door shutter of 35mm thick double shutters with bond wood solid block board type core having cross bands and face veneers, hot pressed bonded with water proof phenol formaldehyde synthetic resin factory made conforming to IS 2202-1991 (Part-I) both sides commercial ply with internal lipping on all sides including cost and conveyance to site of teak wood frame, flush shutter including supply and fixing 6 nos MS Z hold fasts of size 300 mm x 40 mm x 5mm including cost of ISI marked brass fixtures of 6 Nos butt hinges (IS:205) 150mm long , 1 No. aldrop (IS:2681) 300mm long, 2 Nos tower bolts- 10mm (IS:204) of 200 mm long at top, 1 No. tower bolt- 10mm bolt (IS:204) 150mm long at bottom, 2 Nos. 150mm long fancy handles (IS:208) , 2 Nos door stopper and 2 Nos rubber bushes including fixing the fixtures to door with required number of screws, bolt and nuts including labour charges for fixing the frame in position, fixing the shutter to the frame, fixing glass in fan light portion etc., including overheads & contractors profit complete for finished item of work as per APSS 1001 & 1002 The vertical frame of door shall be embedded in flooring for a depth of not less than 10 mm) (2000mm x 2600mm).

16

-

84352

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Providing & Fixing of Scientific Doors with metal door frames and door shutters made of galvanize steel (base steel as per IS 513 of 0.58 mm thick D quality, galvanized as per IS 277 with Zinc of 120 GSM) coated with Zinc Phosphate Primer to receive any paint on site or finished with Thermosetting Polyurethane paint of Aliphatic Grade providing high levels of scratch resistance and durability/Epoxy polyester powder for powder coating paint thickness 50-60 microns (Dry film thickness) outer frame section of 100 x 58 mm x 1.2 mm thick, shutter section of 0.80 mm thick galvanized steel sheet pressed (roll formed) for 46mm thick fully flush, double skin door shell seam joints at stile edges, in-fill of honeycomb kraft paper used to give the required rigidity and effective acoustic insulation with 6? Tower bolt ? 2 Nos., 6? D handles ? 2 Nos., 10? Aldrop ? 1 No., Butt Hinges ? 6 Nos, Mortise Lock ofapproved quality ? 1 No, frames fixed to the concrete/masonry wall by means of self expanding screws including overheads and contractor profit etc., complete for finished item of work for Double leaf Door.

21

-

279174

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and fixing of two shutter main door cum fixed window as per approved drawing with best teak wood frame of section 150mm x 100 mm with fixed fan light of 500mm at top and fixed panels of 600mm width at sides fixed with 12mm thick Tinted - Bronze/Green glass using 12mm x 12mm teak wood beading and fixing ornamental grill made of 25mm x 5mm MS flats as per the approved drawing in fan light portion and fixed panels and 1st class teak wood top and middle rails & styles of section 120mm x 35mm, bottom rail of size 150mm x 35mm and 12mm thick plain float glass for shutter with ornamental etching including cost and conveyance to site of teak wood frame, shutters, glass including supply and fixing 6 nos MS Zhold fasts of size 300 mm x 40 mm x 5mm including cost of ISI marked brass fixtures of 8 Nos butt hinges(IS:205) 250mm long , 1 No. aldrop (IS:2681) 450mm long, 3 Nos tower bolts- 10mm (IS:204) of 200 mm long , 2 Nos 450 mm long fancy handles, 2 Nos door stoppers including fixing the fixtures to door with required number of screws, bolt and nuts including labour charges for fixing the frame in position, fixing the shutters to the frame, fixing glass in fan light portion etc., including overheads & contractors profit complete for finished item of work as per APSS 1001 & 1002 (The vertical frame of door shall be embedded in flooring for a depth of not less than 40 mm) (3000mm x 2600mm).

8

-

89360

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Providing 110 mm Dia ISI marked PVC down water take pipes with socket , 2.5mm thick 4.0 kg/sq.cm pressure of ISI marked including cost of necessary PVC Bends, shoes, iron / PVC clamps and all other accessories and fixing in position including cost and conveyance of all materials, sales & other taxes on materials to site, operational & incidental charges including all labour charges for fixing at site etc., and overheads & contractors profit complete for finished item of work. (APSS No. 1328).

500

-

148500

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Providing skirting to internal walls 15cm height with High Polished Granite 16 to 18 mm thick up to 8'-00 (2.43 M) other than black and regular colours, length equal to flooring slabs set over base coat of CM(1:5) 12 mm thick using screened sand with cement slurry of honey like consistency spread at the rate of 3.30 kgs per sqm and jointing with white cement paste mixed with pigment of matching shade to full depth, including cost of all materials like tiles, cement, sand and water etc., and overheads & contractors profit complete for finished item of work.: Third Floor

50

-

32250

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Providing skirting to internal walls 15cm height with High Polished Granite 16 to 18 mm thick up to 8'-00 (2.43 M) other than black and regular colours, length equal to flooring slabs set over base coat of CM(1:5) 12 mm thick using screened sand with cement slurry of honey like consistency spread at the rate of 3.30 kgs per sqm and jointing with white cement paste mixed with pigment of matching shade to full depth, including cost of all materials like tiles, cement, sand and water etc., and overheads & contractors profit complete for finished item of work.: Second Floor

50

-

31900

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Providing skirting to internal walls 15cm height with High Polished Granite 16 to 18 mm thick up to 8'-00 (2.43 M) other than black and regular colours, length equal to flooring slabs set over base coat of CM(1:5) 12 mm thick using screened sand with cement slurry of honey like consistency spread at the rate of 3.30 kgs per sqm and jointing with white cement paste mixed with pigment of matching shade to full depth, including cost of all materials like tiles, cement, sand and water etc., and overheads & contractors profit complete for finished item of work.: First Floor

50

-

31500

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Providing skirting to internal walls up to 15 cm height with with Nano polished /stain free soluble salt porcelain vitrified tiles screen printed of size 600 x 600 mm and thickness between 8-10 mm 1st quality conforming to IS:13711, IS:13712, IS:13630 (Parts 1 to 15) of any colour and finish in all shades and designs, length equal to flooring tiles, set over base coat of CM(1:5) 12 mm thick using screened sand with cement slurry of honey like consistency spread at the rate of 3.30 kgs per sqm and jointing with white cement paste mixed with pigment of matching shade to full depth, including cost of all materials like tiles, cement, sand and water etc.,and overheads & contractors profit complete for finished item of work.(APSS No.701 &707)TF

8

-

1376

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Providing skirting to internal walls up to 15 cm height with with Nano polished /stain free soluble salt porcelain vitrified tiles screen printed of size 600 x 600 mm and thickness between 8-10 mm 1st quality conforming to IS:13711, IS:13712, IS:13630 (Parts 1 to 15) of any colour and finish in all shades and designs, length equal to flooring tiles, set over base coat of CM(1:5) 12 mm thick using screened sand with cement slurry of honey like consistency spread at the rate of 3.30 kgs per sqm and jointing with white cement paste mixed with pigment of matching shade to full depth, including cost of all materials like tiles, cement, sand and water etc.,and overheads & contractors profit complete for finished item of work.(APSS No.701 &707) SF

16

-

2656

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Providing skirting to internal walls up to 15 cm height with with Nano polished /stain free soluble salt porcelain vitrified tiles screen printed of size 600 x 600 mm and thickness between 8-10 mm 1st quality conforming to IS:13711, IS:13712, IS:13630 (Parts 1 to 15) of any colour and finish in all shades and designs, length equal to flooring tiles, set over base coat of CM(1:5) 12 mm thick using screened sand with cement slurry of honey like consistency spread at the rate of 3.30 kgs per sqm and jointing with white cement paste mixed with pigment of matching shade to full depth, including cost of all materials like tiles, cement, sand and water etc.,and overheads & contractors profit complete for finished item of work.(APSS No.701 &707) FF

38

-

6042

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Providing dadooing to walls with glazed full body porcelain wall tiles of size 300 x 600 mm with any type of design texture such as marble finish, wooden, bamboo, stone finishes etc., scratch less, stain free and thickness between 6-8 mm 1st quality conforming to IS:13711, IS:13712, IS:13630 (Parts 1 to 15) of any colour and finish in all shades and designs with borders as approved by Engineer-in-Charge set over base coat of CM(1:5) 12 mm thick using screened sand with cement slurry of honey like consistency spread at the rate of 3.30 kgs per sqm and jointing with white cement paste mixed with pigment of matching shade to full depth, including cost of all materials like tiles, cement, sand and water etc., complete overheads & contractors profit complete for finished item of work. TF

1455

-

1635420

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Providing dadooing to walls with glazed full body porcelain wall tiles of size 300 x 600 mm with any type of design texture such as marble finish, wooden, bamboo, stone finishes etc., scratch less, stain free and thickness between 6-8 mm 1st quality conforming to IS:13711, IS:13712, IS:13630 (Parts 1 to 15) of any colour and finish in all shades and designs with borders as approved by Engineer-in-Charge set over base coat of CM(1:5) 12 mm thick using screened sand with cement slurry of honey like consistency spread at the rate of 3.30 kgs per sqm and jointing with white cement paste mixed with pigment of matching shade to full depth, including cost of all materials like tiles, cement, sand and water etc., complete overheads & contractors profit complete for finished item of work. SF

1041

-

1158633

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Providing dadooing to walls with glazed full body porcelain wall tiles of size 300 x 600 mm with any type of design texture such as marble finish, wooden, bamboo, stone finishes etc., scratch less, stain free and thickness between 6-8 mm 1st quality conforming to IS:13711, IS:13712, IS:13630 (Parts 1 to 15) of any colour and finish in all shades and designs with borders as approved by Engineer-in-Charge set over base coat of CM(1:5) 12 mm thick using screened sand with cement slurry of honey like consistency spread at the rate of 3.30 kgs per sqm and jointing with white cement paste mixed with pigment of matching shade to full depth, including cost of all materials like tiles, cement, sand and water etc., complete overheads & contractors profit complete for finished item of work. FF

511

-

563122

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Providing dadooing to walls with glazed full body ceramic tiles of any size and thickness between 5 to 7mm 1st quality conforming to IS: 13711, IS: 13712, IS: 13630(Parts 1 to 15) of any colour and finish in all shades and designs with borders as approved by Engineer-in-Charge set over base coat of CM(1:5) 12 mm thick using screened sand with cement slurry of honey like consistency spread at the rate of 3.30 kgs per sqm and jointing with white cement paste mixed with pigment of matching shade to full depth, including cost of all materials like tiles, cement, sand and water etc., and overheads & contractors profit complete for finished item of work. (for Toilets). TF

339

-

280692

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Providing dadooing to walls with glazed full body ceramic tiles of any size and thickness between 5 to 7mm 1st quality conforming to IS: 13711, IS: 13712, IS: 13630(Parts 1 to 15) of any colour and finish in all shades and designs with borders as approved by Engineer-in-Charge set over base coat of CM(1:5) 12 mm thick using screened sand with cement slurry of honey like consistency spread at the rate of 3.30 kgs per sqm and jointing with white cement paste mixed with pigment of matching shade to full depth, including cost of all materials like tiles, cement, sand and water etc., and overheads & contractors profit complete for finished item of work. (for Toilets). SF

131

-

107027

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Providing dadooing to walls with glazed full body ceramic tiles of any size and thickness between 5 to 7mm 1st quality conforming to IS: 13711, IS: 13712, IS: 13630(Parts 1 to 15) of any colour and finish in all shades and designs with borders as approved by Engineer-in-Charge set over base coat of CM(1:5) 12 mm thick using screened sand with cement slurry of honey like consistency spread at the rate of 3.30 kgs per sqm and jointing with white cement paste mixed with pigment of matching shade to full depth, including cost of all materials like tiles, cement, sand and water etc., and overheads & contractors profit complete for finished item of work. (for Toilets). FF

187

-

150722

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Flooring with 16 to 18 mm thick high polished granite stone slabs black colour as approved by the Engineer-in-Charge of length not less than 2.43 mts set over base coat of cement mortar (1:8) , 20mm thick using screened sand over CC bed already laid or RCC roof slab including neat grey cement slurry of honey like consistency spread @ 3.3 Kg per sqm and jointed neatly with white cement paste mixed with pigment of matching shade to full depth including cost and conveyance of all materials like cement , sand , water , granite slabs etc., to work site and all operational, incidental labour & lift charges, half rounding the edge , polishing charges and all other taxes on all materials, cost of base coat and overheads & contractors profit complete for finished item of work for platforms (S.S.701 & special) TF

43

-

210786

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Flooring with 16 to 18 mm thick high polished granite stone slabs black colour as approved by the Engineer-in-Charge of length not less than 2.43 mts set over base coat of cement mortar (1:8) , 20mm thick using screened sand over CC bed already laid or RCC roof slab including neat grey cement slurry of honey like consistency spread @ 3.3 Kg per sqm and jointed neatly with white cement paste mixed with pigment of matching shade to full depth including cost and conveyance of all materials like cement , sand , water , granite slabs etc., to work site and all operational, incidental labour & lift charges, half rounding the edge , polishing charges and all other taxes on all materials, cost of base coat and overheads & contractors profit complete for finished item of work for platforms (S.S.701 & special) SF

39

-

187941

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Flooring with 16 to 18 mm thick high polished granite stone slabs black colour as approved by the Engineer-in-Charge of length not less than 2.43 mts set over base coat of cement mortar (1:8) , 20mm thick using screened sand over CC bed already laid or RCC roof slab including neat grey cement slurry of honey like consistency spread @ 3.3 Kg per sqm and jointed neatly with white cement paste mixed with pigment of matching shade to full depth including cost and conveyance of all materials like cement , sand , water , granite slabs etc., to work site and all operational, incidental labour & lift charges, half rounding the edge , polishing charges and all other taxes on all materials, cost of base coat and overheads & contractors profit complete for finished item of work for platforms (S.S.701 & special) FF

36

-

170532

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Providing 16 to 18mm thick high polished granite stone slabs other than black and regular colours (i.e. of shades like paradiso / bala flower / copper silk / laka red / lavender blue) with borders and design as per the pattern approved by the Engineer-in-Charge of length not less than 2.43 mts set over base coat of cement mortar (1:5) , 12mm thick using screened sand over CC bed already laid or RCC roof slab including neat grey cement slurry of honey like consistency spread @ 3.3 Kg per sqm and jointed neatly with white cement paste mixed with pigment of matching shade to full depth including cost and conveyance of all materials like cement , sand , water , granite slabs etc., to work site and all operational, incidental labour & lift charges, half rounding the edges of treads , polishing charges and all other taxes on all materials, cost of base coat and overheads & contractors profit complete for finished item of work for Risers (S.S.701 & special) TF

8

-

33528

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Providing 16 to 18mm thick high polished granite stone slabs other than black and regular colours (i.e. of shades like paradiso / bala flower / copper silk / laka red / lavender blue) with borders and design as per the pattern approved by the Engineer-in-Charge of length not less than 2.43 mts set over base coat of cement mortar (1:5) , 12mm thick using screened sand over CC bed already laid or RCC roof slab including neat grey cement slurry of honey like consistency spread @ 3.3 Kg per sqm and jointed neatly with white cement paste mixed with pigment of matching shade to full depth including cost and conveyance of all materials like cement , sand , water , granite slabs etc., to work site and all operational, incidental labour & lift charges, half rounding the edges of treads , polishing charges and all other taxes on all materials, cost of base coat and overheads & contractors profit complete for finished item of work for Risers (S.S.701 & special) SF

8

-

33360

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Providing 16 to 18mm thick high polished granite stone slabs other than black and regular colours (i.e. of shades like paradiso / bala flower / copper silk / laka red / lavender blue) with borders and design as per the pattern approved by the Engineer-in-Charge of length not less than 2.43 mts set over base coat of cement mortar (1:5) , 12mm thick using screened sand over CC bed already laid or RCC roof slab including neat grey cement slurry of honey like consistency spread @ 3.3 Kg per sqm and jointed neatly with white cement paste mixed with pigment of matching shade to full depth including cost and conveyance of all materials like cement , sand , water , granite slabs etc., to work site and all operational, incidental labour & lift charges, half rounding the edges of treads , polishing charges and all other taxes on all materials, cost of base coat and overheads & contractors profit complete for finished item of work for Risers (S.S.701 & special) FF

19

-

78831

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Providing 16 to 18mm thick high polished granite stone slabs other than black and regular colours (i.e. of shades like paradiso / bala flower / copper silk / laka red / lavender blue) with borders and design as per the pattern approved by the Engineer-in-Charge of length not less than 2.43 mts set over base coat of cement mortar (1:5) , 12mm thick using screened sand over CC bed already laid or RCC roof slab including neat grey cement slurry of honey like consistency spread @ 3.3 Kg per sqm and jointed neatly with white cement paste mixed with pigment of matching shade to full depth including cost and conveyance of all materials like cement , sand , water , granite slabs etc., to work site and all operational, incidental labour & lift charges, half rounding the edges of treads , polishing charges and all other taxes on all materials, cost of base coat and overheads & contractors profit complete for finished item of work for treads (S.S.701 & special) TF

14

-

87976

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Providing 16 to 18mm thick high polished granite stone slabs other than black and regular colours (i.e. of shades like paradiso / bala flower / copper silk / laka red / lavender blue) with borders and design as per the pattern approved by the Engineer-in-Charge of length not less than 2.43 mts set over base coat of cement mortar (1:5) , 12mm thick using screened sand over CC bed already laid or RCC roof slab including neat grey cement slurry of honey like consistency spread @ 3.3 Kg per sqm and jointed neatly with white cement paste mixed with pigment of matching shade to full depth including cost and conveyance of all materials like cement , sand , water , granite slabs etc., to work site and all operational, incidental labour & lift charges, half rounding the edges of treads , polishing charges and all other taxes on all materials, cost of base coat and overheads & contractors profit complete for finished item of work for treads (S.S.701 & special) SF

14

-

86814

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Providing 16 to 18mm thick high polished granite stone slabs other than black and regular colours (i.e. of shades like paradiso / bala flower / copper silk / laka red / lavender blue) with borders and design as per the pattern approved by the Engineer-in-Charge of length not less than 2.43 mts set over base coat of cement mortar (1:5) , 12mm thick using screened sand over CC bed already laid or RCC roof slab including neat grey cement slurry of honey like consistency spread @ 3.3 Kg per sqm and jointed neatly with white cement paste mixed with pigment of matching shade to full depth including cost and conveyance of all materials like cement , sand , water , granite slabs etc., to work site and all operational, incidental labour & lift charges, half rounding the edges of treads , polishing charges and all other taxes on all materials, cost of base coat and overheads & contractors profit complete for finished item of work for treads (S.S.701 & special) FF

56

-

342608

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Granolithic Concrete flooring 20 mm thick with (1:1:2), using 6mm to 12 mm size hard granite machine crushed metal and screened sand laid over CC bed already laid or RCC roof slab, in alternate panels of size not exceeding 1.50 m x 1.50 m, using glass strips and finishing the top surface to required smoothness and slopes and thread lining including cost of all materials like cement, metal sand and water and overheads & contractors profit complete for finished item of work. (APSS No.701 & 710).

36

-

15084

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Flooring with chequered cement concrete heavy duty tiles confirming to IS:13801 using aggregates, cement, pigments of size 300mm x 300mm and thickness 25mm of any shade as approved by Engineer-In-Charge set over base coat of cement mortar (1:6), 12 mm thick using screened sand over CC bed alredy laid or RCC roof slab including neat cement slurry of honey like consistency spread @ 3.3 kgs per sqm and jointed with neat white cement to full depth mixed with pigment of matching shade including cost and conveyance of all materials like cement, sand, water and tiles etc.,and overheads & contractors profit complete for finished item of work. SF

63

-

57141

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Flooring with chequered cement concrete heavy duty tiles confirming to IS:13801 using aggregates, cement, pigments of size 300mm x 300mm and thickness 25mm of any shade as approved by Engineer-In-Charge set over base coat of cement mortar (1:6), 12 mm thick using screened sand over CC bed alredy laid or RCC roof slab including neat cement slurry of honey like consistency spread @ 3.3 kgs per sqm and jointed with neat white cement to full depth mixed with pigment of matching shade including cost and conveyance of all materials like cement, sand, water and tiles etc.,and overheads & contractors profit complete for finished item of work. FF

740

-

611240

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Flooring with Nano polished /stain free soluble salt porcelain vitrified tiles screen printed of size 600 x 600 mm and thickness between 8-10 mm 1st quality conforming to IS:13711, IS:13712, IS:13630 (Parts 1 to 15) of any colour and finish in all shades and designs as per the approved flooring pattern as directed by the Engineer-In -Charge, laying tiles using spacers of 2mm thick, set over a base coat of CM (1:8) prop. 12mm thick using screened sand over CC bed already laid or RCC roof slab , including neat cement slurry of honey like consistancy spread @ 3.3 kgs per Sqm. and jointed neately with white cement paste to full depth mixed with pigment of matching shade including cost and conveyance of all materials like cement, sand, water, tiles, white cement etc., to site (excluding cost of C.C. bed) including cost of base coat and all labour charges for mixing of cement mortar, laying tiles to required slope as directed by the Engineer- in-charge etc.,and overheads & contractors profit complete for finished item of work. (APSS No.701 & 707). TF

1708

-

1972740

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Flooring with Nano polished /stain free soluble salt porcelain vitrified tiles screen printed of size 600 x 600 mm and thickness between 8-10 mm 1st quality conforming to IS:13711, IS:13712, IS:13630 (Parts 1 to 15) of any colour and finish in all shades and designs as per the approved flooring pattern as directed by the Engineer-In -Charge, laying tiles using spacers of 2mm thick, set over a base coat of CM (1:8) prop. 12mm thick using screened sand over CC bed already laid or RCC roof slab , including neat cement slurry of honey like consistancy spread @ 3.3 kgs per Sqm. and jointed neately with white cement paste to full depth mixed with pigment of matching shade including cost and conveyance of all materials like cement, sand, water, tiles, white cement etc., to site (excluding cost of C.C. bed) including cost of base coat and all labour charges for mixing of cement mortar, laying tiles to required slope as directed by the Engineer- in-charge etc.,and overheads & contractors profit complete for finished item of work. (APSS No.701 & 707). SF

1097

-

1217670

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Flooring with Nano polished /stain free soluble salt porcelain vitrified tiles screen printed of size 600 x 600 mm and thickness between 8-10 mm 1st quality conforming to IS:13711, IS:13712, IS:13630 (Parts 1 to 15) of any colour and finish in all shades and designs as per the approved flooring pattern as directed by the Engineer-In -Charge, laying tiles using spacers of 2mm thick, set over a base coat of CM (1:8) prop. 12mm thick using screened sand over CC bed already laid or RCC roof slab , including neat cement slurry of honey like consistancy spread @ 3.3 kgs per Sqm. and jointed neately with white cement paste to full depth mixed with pigment of matching shade including cost and conveyance of all materials like cement, sand, water, tiles, white cement etc., to site (excluding cost of C.C. bed) including cost of base coat and all labour charges for mixing of cement mortar, laying tiles to required slope as directed by the Engineer- in-charge etc.,and overheads & contractors profit complete for finished item of work. (APSS No.701 & 707). FF

637

-

679042

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Flooring with non-skid full body ceramic floor tiles of size 300mm x 300mm and thickness between 7 - 8mm 1st quality conforming to IS: 13711, IS: 13712, IS: 13630(Part 1 to 15) of any colour and finish in all shades and designs as approved by Engineer-in-charge, set over base coat of cement mortar (1:8), 12mm thick using screened sandover CC bed already laid or RCC roof slab, including neat cement slurry of honey like consistency spread @ 3.3 Kgs per Sqm & jointed epoxy emulsion grout/ synthetic /resin adhesive in width of 3-5 mm with Nylonspacers excluding cost of tiles neatly with to full depth mixed with pigment of matching shade, including cost of all materials like cement, screened sand , water and tiles etc., and overheads & contractors profit complete for finished item of work. (In toilets) (APSS No.701 & 707) . TF

119

-

165291

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Flooring with non-skid full body ceramic floor tiles of size 300mm x 300mm and thickness between 7 - 8mm 1st quality conforming to IS: 13711, IS: 13712, IS: 13630(Part 1 to 15) of any colour and finish in all shades and designs as approved by Engineer-in-charge, set over base coat of cement mortar (1:8), 12mm thick using screened sandover CC bed already laid or RCC roof slab, including neat cement slurry of honey like consistency spread @ 3.3 Kgs per Sqm & jointed epoxy emulsion grout/ synthetic /resin adhesive in width of 3-5 mm with Nylonspacers excluding cost of tiles neatly with to full depth mixed with pigment of matching shade, including cost of all materials like cement, screened sand , water and tiles etc., and overheads & contractors profit complete for finished item of work. (In toilets) (APSS No.701 & 707) . SF

53

-

71285

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Flooring with non-skid full body ceramic floor tiles of size 300mm x 300mm and thickness between 7 - 8mm 1st quality conforming to IS: 13711, IS: 13712, IS: 13630(Part 1 to 15) of any colour and finish in all shades and designs as approved by Engineer-in-charge, set over base coat of cement mortar (1:8), 12mm thick using screened sand over CC bed already laid or RCC roof slab, including neat cement slurry of honey like consistency spread @ 3.3 Kgs per Sqm & jointed neatly with white cement paste to full depth mixed with pigment of matching shade, including cost of all materials like cement, screened sand , water and tiles etc., and overheads & contractors profit complete for finished item of work. (APSS No.701 & 707).

76

-

68172

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Providing impervious coat to exposed RCC roof slab surfaces of sump, sump side wall,sump bottom slab, in side of septic tank, in sunken slabs etc. to required slopes with CM (1:3) prop. using screened sand 12mm thick mixed with integral cement water proofing liquid confirming to IS: 2645-2003 manufactured by reputed manufacturers as approved by Engineer-in-charge at 1 Kg per one bag of cement, laid over roof slab when it is green, finished smooth with a floating coat of neat cement and thread lining at regular intervals of 45cm x 45cm where ever necessary including cost and conveyance of all materials like cement, sand, water proofing compound, water etc., to site, including sales & other taxes on all materials and operational, incidental, and labour charges for mixing mortar, laying, lift charges, rendering smooth and thread lining, curing including rounding off junctions of wall and slab etc., and overheads & contractors profit complete for finished item of work. (APSS No. 901 & 903). TF

121

-

25652

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Providing impervious coat to exposed RCC roof slab surfaces of sump, sump side wall,sump bottom slab, in side of septic tank, in sunken slabs etc. to required slopes with CM (1:3) prop. using screened sand 12mm thick mixed with integral cement water proofing liquid confirming to IS: 2645-2003 manufactured by reputed manufacturers as approved by Engineer-in-charge at 1 Kg per one bag of cement, laid over roof slab when it is green, finished smooth with a floating coat of neat cement and thread lining at regular intervals of 45cm x 45cm where ever necessary including cost and conveyance of all materials like cement, sand, water proofing compound, water etc., to site, including sales & other taxes on all materials and operational, incidental, and labour charges for mixing mortar, laying, lift charges, rendering smooth and thread lining, curing including rounding off junctions of wall and slab etc., and overheads & contractors profit complete for finished item of work. (APSS No. 901 & 903). SF

53

-

10653

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Providing impervious coat to exposed RCC roof slab surfaces of sump, sump side wall,sump bottom slab, in side of septic tank, in sunken slabs etc. to required slopes with CM (1:3) prop. using screened sand 12mm thick mixed with integral cement water proofing liquid confirming to IS: 2645-2003 manufactured by reputed manufacturers as approved by Engineer-in-charge at 1 Kg per one bag of cement, laid over roof slab when it is green, finished smooth with a floating coat of neat cement and thread lining at regular intervals of 45cm x 45cm where ever necessary including cost and conveyance of all materials like cement, sand, water proofing compound, water etc., to site, including sales & other taxes on all materials and operational, incidental, and labour charges for mixing mortar, laying, lift charges, rendering smooth and thread lining, curing including rounding off junctions of wall and slab etc., and overheads & contractors profit complete for finished item of work. (APSS No. 901 & 903). FF

367

-

69730

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Providing impervious coat to exposed RCC roof slab surfaces to required slopes with CM (1:3) prop. using screened sand 20mm thick (average) mixed with integral cement water proofing liquid confirming to IS: 2645-2003 manufactured by reputed manufacturers as approved by Engineer-in-charge at 1 Kg per one bag of cement, laid over roof slab when it is green, finished smooth with a floating coat of neat cement and thread lining at regular intervals of 45cmx45cm including cost and conveyance of all materials like cement, sand, water proofing compound, water etc., to site, including sales & other taxes on all materials and operational, incidental, and labour charges for mixing mortar, laying, lift charges, rendering smooth and thread lining, curing including rounding off junctions of wall and slab etc., and overheads & contractors profit complete for finished item of work. (APSS No. 901 & 903). FF

2200

-

1412400

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Providing impervious coat to exposed RCC roof slab surfaces to required slopes with CM (1:3) prop. using screened sand 20mm thick (average) mixed with integral cement water proofing liquid confirming to IS: 2645-2003 manufactured by reputed manufacturers as approved by Engineer-in-charge at 1 Kg per one bag of cement, laid over roof slab when it is green, finished smooth with a floating coat of neat cement and thread lining at regular intervals of 45cmx45cm including cost and conveyance of all materials like cement, sand, water proofing compound, water etc., to site, including sales & other taxes on all materials and operational, incidental, and labour charges for mixing mortar, laying, lift charges, rendering smooth and thread lining, curing including rounding off junctions of wall and slab etc., and overheads & contractors profit complete for finished item of work. (APSS No. 901 & 903). TF

185

-

111185

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Providing impervious coat to exposed RCC roof slab surfaces to required slopes with CM (1:3) prop. using screened sand 20mm thick (average) mixed with integral cement water proofing liquid confirming to IS: 2645-2003 manufactured by reputed manufacturers as approved by Engineer-in-charge at 1 Kg per one bag of cement, laid over roof slab when it is green, finished smooth with a floating coat of neat cement and thread lining at regular intervals of 45cmx45cm including cost and conveyance of all materials like cement, sand, water proofing compound, water etc., to site, including sales & other taxes on all materials and operational, incidental, and labour charges for mixing mortar, laying, lift charges, rendering smooth and thread lining, curing including rounding off junctions of wall and slab etc., and overheads & contractors profit complete for finished item of work. (APSS No. 901 & 903). FF

163

-

84923

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Plastering 12mm thick in two coats using screened sand with base coat of 8mm thick in CM (1:6) and top coat of 4mm thick in CM (1:4) with dubara sponge finishing including cost and conveyance of all materials like cement, sand, water etc., to site, including sales & other taxes on all materials, and all operational, incidental charges on materials and including cost of all labour charges for mixing mortar, finishing, scaffolding, lift charges, curing, including cutting grooves as directed by Engineer-in-charge etc., and overheads & contractors profit complete for finished item of work. (SS 901,903 & 904) for external walls. FF

934

-

580014

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Plastering 12mm thick in two coats using screened sand with base coat of 8mm thick in CM (1:6) and top coat of 4mm thick in CM (1:4) with dubara sponge finishing including cost and conveyance of all materials like cement, sand, water etc., to site, including sales & other taxes on all materials, and all operational, incidental charges on materials and including cost of all labour charges for mixing mortar, finishing, scaffolding, lift charges, curing, including cutting grooves as directed by Engineer-in-charge etc., and overheads & contractors profit complete for finished item of work. (SS 901,903 & 904) for external walls. TF

1313

-

753662

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Plastering 12mm thick in two coats using screened sand with base coat of 8mm thick in CM (1:6) and top coat of 4mm thick in CM (1:4) with dubara sponge finishing including cost and conveyance of all materials like cement, sand, water etc., to site, including sales & other taxes on all materials, and all operational, incidental charges on materials and including cost of all labour charges for mixing mortar, finishing, scaffolding, lift charges, curing, including cutting grooves as directed by Engineer-in-charge etc., and overheads & contractors profit complete for finished item of work. (SS 901,903 & 904) for external walls. SF

886

-

467808

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Plastering 12mm thick in two coats using screened sand with base coat of 8mm thick in CM (1:6) and top coat of 4mm thick in CM (1:4) with dubara sponge finishing including cost and conveyance of all materials like cement, sand, water etc., to site, including sales & other taxes on all materials, and all operational, incidental charges on materials and including cost of all labour charges for mixing mortar, finishing, scaffolding, lift charges, curing, including cutting grooves as directed by Engineer-in-charge etc., and overheads & contractors profit complete for finished item of work. (SS 901,903 & 904) for external walls. FF

830

-

399230

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Plastering 12mm thick in two coats using screened sand with base coat of 8mm thick in CM (1:6) and top coat of 4mm thick in CM (1:4) with dubara sponge finishing including cost and conveyance of all materials like cement, sand, water etc., to site, including sales & other taxes on all materials, and all operational, incidental charges on materials and including cost of all labour charges for mixing mortar, finishing, scaffolding, lift charges, curing, including cutting grooves as directed by Engineer-in-charge etc., and overheads & contractors profit complete for finished item of work. (SS 901,903 & 904). for internal walls. FF

108

-

67068

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Plastering 12mm thick in two coats using screened sand with base coat of 8mm thick in CM (1:6) and top coat of 4mm thick in CM (1:4) with dubara sponge finishing including cost and conveyance of all materials like cement, sand, water etc., to site, including sales & other taxes on all materials, and all operational, incidental charges on materials and including cost of all labour charges for mixing mortar, finishing, scaffolding, lift charges, curing, including cutting grooves as directed by Engineer-in-charge etc., and overheads & contractors profit complete for finished item of work. (SS 901,903 & 904). for internal walls. TF

3342

-

1918308

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Plastering 12mm thick in two coats using screened sand with base coat of 8mm thick in CM (1:6) and top coat of 4mm thick in CM (1:4) with dubara sponge finishing including cost and conveyance of all materials like cement, sand, water etc., to site, including sales & other taxes on all materials, and all operational, incidental charges on materials and including cost of all labour charges for mixing mortar, finishing, scaffolding, lift charges, curing, including cutting grooves as directed by Engineer-in-charge etc., and overheads & contractors profit complete for finished item of work. (SS 901,903 & 904). for internal walls. SF

2144

-

1132032

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Plastering 12mm thick in two coats using screened sand with base coat of 8mm thick in CM (1:6) and top coat of 4mm thick in CM (1:4) with dubara sponge finishing including cost and conveyance of all materials like cement, sand, water etc., to site, including sales & other taxes on all materials, and all operational, incidental charges on materials and including cost of all labour charges for mixing mortar, finishing, scaffolding, lift charges, curing, including cutting grooves as directed by Engineer-in-charge etc., and overheads & contractors profit complete for finished item of work. (SS 901,903 & 904). for internal walls. FF

1509

-

725829

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Plastering 12mm thick single coat in CM(1:5) using screened sand including cost and conveyance of all materials like cement, sand, water etc., to site, including sales & other taxes on all materials, and all operational, incidental charges on materials and including cost of all labour charges for mixing mortar, finishing, curing as directed by Engineer-in-charge etc., and overheads & contractors profit complete for finished item of work.(SS 901,903 & 904) For External walls

165

-

27225

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Ornamental ceiling plastering 12mm thick in two coats using screened sand with base coat of 8mm thick in CM (1:6) and top coat of 4mm thick in CM (1:4) with dubara sponge finishing including cost and conveyance of all materials like cement, sand, water etc., to site, including sales & other taxes on all materials, and all operational, incidental charges on materials and including cost of all labour charges for mixing mortar, finishing, scaffolding, lift charges, curing, including cutting grooves as directed by Engineer-in- harge etc., and overheads & contractors profit complete for finished item of work. (SS 901,903 & 904). TF

41

-

26650

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Ornamental ceiling plastering 12mm thick in two coats using screened sand with base coat of 8mm thick in CM (1:6) and top coat of 4mm thick in CM (1:4) with dubara sponge finishing including cost and conveyance of all materials like cement, sand, water etc., to site, including sales & other taxes on all materials, and all operational, incidental charges on materials and including cost of all labour charges for mixing mortar, finishing, scaffolding, lift charges, curing, including cutting grooves as directed by Engineer-in- harge etc., and overheads & contractors profit complete for finished item of work. (SS 901,903 & 904). TF

1826

-

1091948

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Ornamental ceiling plastering 12mm thick in two coats using screened sand with base coat of 8mm thick in CM (1:6) and top coat of 4mm thick in CM (1:4) with dubara sponge finishing including cost and conveyance of all materials like cement, sand, water etc., to site, including sales & other taxes on all materials, and all operational, incidental charges on materials and including cost of all labour charges for mixing mortar, finishing, scaffolding, lift charges, curing, including cutting grooves as directed by Engineer-in- harge etc., and overheads & contractors profit complete for finished item of work. (SS 901,903 & 904). SF

1140

-

623580

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Ornamental ceiling plastering 12mm thick in two coats using screened sand with base coat of 8mm thick in CM (1:6) and top coat of 4mm thick in CM (1:4) with dubara sponge finishing including cost and conveyance of all materials like cement, sand, water etc., to site, including sales & other taxes on all materials, and all operational, incidental charges on materials and including cost of all labour charges for mixing mortar, finishing, scaffolding, lift charges, curing, including cutting grooves as directed by Engineer-in- harge etc., and overheads & contractors profit complete for finished item of work. (SS 901,903 & 904). FF

1322

-

654390

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Providing Mild steel (MS) steel bars (Fe 250 grade as per IS 432) of different diameters including labour charges for straightening, cutting, bending to required sizes and shapes, placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc. ,and overheads & contractors profit complete for finished item of work.(APSS No.126) TF

1

-

89394

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Providing Mild steel (MS) steel bars (Fe 250 grade as per IS 432) of different diameters including labour charges for straightening, cutting, bending to required sizes and shapes, placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc. ,and overheads & contractors profit complete for finished item of work.(APSS No.126) SF

2

-

175894

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Providing Mild steel (MS) steel bars (Fe 250 grade as per IS 432) of different diameters including labour charges for straightening, cutting, bending to required sizes and shapes, placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc. ,and overheads & contractors profit complete for finished item of work.(APSS No.126) FF

1

-

86500

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Providing Thermo Mechanically Treated (TMT) (Fe -500/500D/550D from Primary producer TATA, SAIL, VSP, JSW &Shyam Steel etc as per IS 1786-2008) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes, placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc. ,and overheads & contractors profit complete for finished item of work. (APSS No.126).FF

7

-

635887

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Providing Thermo Mechanically Treated (TMT) (Fe -500/500D/550D from Primary producer TATA, SAIL, VSP, JSW &Shyam Steel etc as per IS 1786-2008) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes, placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc. ,and overheads & contractors profit complete for finished item of work. (APSS No.126).TF

76

-

6793944

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Providing Thermo Mechanically Treated (TMT) (Fe -500/500D/550D from Primary producer TATA, SAIL, VSP, JSW &Shyam Steel etc as per IS 1786-2008) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes, placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc. ,and overheads & contractors profit complete for finished item of work. (APSS No.126).SF

47

-

4133509

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Providing Thermo Mechanically Treated (TMT) (Fe -500/500D/550D from Primary producer TATA, SAIL, VSP, JSW &Shyam Steel etc as per IS 1786-2008) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes, placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc. ,and overheads & contractors profit complete for finished item of work. (APSS No.126).ff

105.94

-

9163410

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Filling with light weight concrete in Cement Concrete (1:5:10) proportion using brick jelly for low roofs including cost and conveyance of all materials like cement, sand, brick bats etc., to site including cost of all labour charges for laying concrete, ramming, curing, overheads & contractors profit etc., complete for finished item of work. (APSS. No. 402) SF

33

-

156156

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Filling with light weight concrete in Cement Concrete (1:5:10) proportion using brick jelly for low roofs including cost and conveyance of all materials like cement, sand, brick bats etc., to site including cost of all labour charges for laying concrete, ramming, curing, overheads & contractors profit etc., complete for finished item of work. (APSS. No. 402) SF

16

-

74112

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Plain Cement Concrete (1:3:6) nominal mix using 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate(sand), coarse aggregate, water etc. to site, including sales & other taxes on all materials and including all charges for mixing, laying concrete in position, curing etc., & lift charges , and overheads & contractors profit for Bed Blocks & Hold Fasts for finished item of work. (APSS No. 402) TF

9

-

56574

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Plain Cement Concrete (1:3:6) nominal mix using 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate(sand), coarse aggregate, water etc. to site, including sales & other taxes on all materials and including all charges for mixing, laying concrete in position, curing etc., & lift charges , and overheads & contractors profit for Bed Blocks & Hold Fasts for finished item of work. (APSS No. 402) SF

6

-

36810

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Plain Cement Concrete (1:3:6) nominal mix using 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate(sand), coarse aggregate, water etc. to site, including sales & other taxes on all materials and including all charges for mixing, laying concrete in position, curing etc., & lift charges , and overheads & contractors profit for Bed Blocks & Hold Fasts for finished item of work. (APSS No. 402) FF

5.56

-

33292

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Plain Cement Concrete M 20 nominal mix using WEIGH BATCHER / MIXER, 20mm size hard granite machine crushed graded metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry, using a minimum quantity of 300 kgs. of cement per 1 cum of concrete including cost and conveyance of all materials like cement, fine aggregate (Sand), coarse aggregate, water etc., to site including steel centering, shuttering, machine mixing, lift charges, laying concrete,vibrating, curing, overheads & contrctors profit etc., complete for finished item of work for coping on top of compound wall (APSS No. 402 & 403).

4

-

24416

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Plain Cement Concrete M 20 design mix using Concrete Batching Plant, 20mm size hard granite machine crushed graded metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry, using a minimum quantity of 330 kgs. of cement per 1 cum of concrete including cost and conveyance of all materials like cement, fine aggregate (Sand), coarse aggregate, water etc., to site including steel centering, shuttering, machine mixing, lift charges, laying concrete,vibrating, curing, overheads & contrctors profit etc., complete for finished item of work (APSS No. 402 & 403) for steps. SF

2

-

15876

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Plain Cement Concrete M 20 design mix using Concrete Batching Plant, 20mm size hard granite machine crushed graded metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry, using a minimum quantity of 330 kgs. of cement per 1 cum of concrete including cost and conveyance of all materials like cement, fine aggregate (Sand), coarse aggregate, water etc., to site including steel centering, shuttering, machine mixing, lift charges, laying concrete,vibrating, curing, overheads & contrctors profit etc., complete for finished item of work (APSS No. 402 & 403) for steps. SF

2

-

15336

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Plain Cement Concrete M 20 design mix using Concrete Batching Plant, 20mm size hard granite machine crushed graded metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry, using a minimum quantity of 330 kgs. of cement per 1 cum of concrete including cost and conveyance of all materials like cement, fine aggregate (Sand), coarse aggregate, water etc., to site including steel centering, shuttering, machine mixing, lift charges, laying concrete,vibrating, curing, overheads & contrctors profit etc., complete for finished item of work (APSS No. 402 & 403) for steps. FF

2

-

14796

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Reinforced Masonry for partition walls (100 mm thick) in CM (1:4) prop. (Cement : Screened sand) using fly ash cement / lime solid blocks of size 290mm x 100mm x 140mm having minimum compressive strength of 50 Kg/Sq.cmand placing 2 Nos. of 6mm M.S plain rods in every third layer with free ends of the reinforcement pegged into mortar joints of main brick walls where applicable including cost and conveyance of all materials like cement, steel, sand, bricks, water etc., to site, including sales & other taxes on all materials, all operational, incidental charges such as labour charges for mixing cement mortar, scaffolding charges, constructing masonry, lift charges, curing, etc., and overheads & contractors profit but excluding cost of steel and its fabrication charges complete for finished item of work. (APSS No. of 509) TF

441

-

424683

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Reinforced Masonry for partition walls (100 mm thick) in CM (1:4) prop. (Cement : Screened sand) using fly ash cement / lime solid blocks of size 290mm x 100mm x 140mm having minimum compressive strength of 50 Kg/Sq.cmand placing 2 Nos. of 6mm M.S plain rods in every third layer with free ends of the reinforcement pegged into mortar joints of main brick walls where applicable including cost and conveyance of all materials like cement, steel, sand, bricks, water etc., to site, including sales & other taxes on all materials, all operational, incidental charges such as labour charges for mixing cement mortar, scaffolding charges, constructing masonry, lift charges, curing, etc., and overheads & contractors profit but excluding cost of steel and its fabrication charges complete for finished item of work. (APSS No. of 509) SF

518

-

456876

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Reinforced Masonry for partition walls (100 mm thick) in CM (1:4) prop. (Cement : Screened sand) using fly ash cement / lime solid blocks of size 290mm x 100mm x 140mm having minimum compressive strength of 50 Kg/Sq.cmand placing 2 Nos. of 6mm M.S plain rods in every third layer with free ends of the reinforcement pegged into mortar joints of main brick walls where applicable including cost and conveyance of all materials like cement, steel, sand, bricks, water etc., to site, including sales & other taxes on all materials, all operational, incidental charges such as labour charges for mixing cement mortar, scaffolding charges, constructing masonry, lift charges, curing, etc., and overheads & contractors profit but excluding cost of steel and its fabrication charges complete for finished item of work. (APSS No. of 509) FF

392

-

313600

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Masonry work in CM (1:6) prop (Cement : Screened sand) in superstructure with fly ash cement / lime solid blocks of size 290mm x 225mm x 140mm from approved source having minimum crushing strength of 50 Kg/Sqcm. including cost and conveyance of all materials like cement, sand, bricks, water etc., to site, including sales & other taxes on all materials and such as labour charges, like mixing cement mortar, scaffolding charges, constructing masonry, lift charges, curing, overheads and contrctor profit etc., complete for finished item of work. (APSS No. 501 & 504). FF

63

-

543186

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Masonry work in CM (1:6) prop (Cement : Screened sand) in superstructure with fly ash cement / lime solid blocks of size 290mm x 225mm x 140mm from approved source having minimum crushing strength of 50 Kg/Sqcm. including cost and conveyance of all materials like cement, sand, bricks, water etc., to site, including sales & other taxes on all materials and such as labour charges, like mixing cement mortar, scaffolding charges, constructing masonry, lift charges, curing, overheads and contrctor profit etc., complete for finished item of work. (APSS No. 501 & 504). TF

413

-

3346539

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Masonry work in CM (1:6) prop (Cement : Screened sand) in superstructure with fly ash cement / lime solid blocks of size 290mm x 225mm x 140mm from approved source having minimum crushing strength of 50 Kg/Sqcm. including cost and conveyance of all materials like cement, sand, bricks, water etc., to site, including sales & other taxes on all materials and such as labour charges, like mixing cement mortar, scaffolding charges, constructing masonry, lift charges, curing, overheads and contrctor profit etc., complete for finished item of work. (APSS No. 501 & 504). SF

223

-

1691455

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Masonry work in CM (1:6) prop (Cement : Screened sand) in superstructure with fly ash cement / lime solid blocks of size 290mm x 225mm x 140mm from approved source having minimum crushing strength of 50 Kg/Sqcm. including cost and conveyance of all materials like cement, sand, bricks, water etc., to site, including sales & other taxes on all materials and such as labour charges, like mixing cement mortar, scaffolding charges, constructing masonry, lift charges, curing, overheads and contrctor profit etc., complete for finished item of work. (APSS No. 501 & 504). FF

186

-

1314276

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Masonry work in CM (1:6) prop (Cement : Screened sand) in superstructure with fly ash cement / lime solid blocks of size 290mm x 225mm x 140mm from approved source having minimum crushing strength of 50 Kg/Sqcm. including cost and conveyance of all materials like cement, sand, bricks, water etc., to site, including sales & other taxes on all materials and such as labour charges, like mixing cement mortar, scaffolding charges, constructing masonry, lift charges, curing, overheads and contrctor profit etc., complete for finished item of work. (APSS No. 501 & 504).

39

-

252525

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Reinforced Cement Concrete M 20 design mix using 12mm size hard granite machine crushed graded metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry, using a minimum quantity of 350 kgs. of cement per 1 cum of concrete using WEIGH BATCHER / MIXER including cost and conveyance of all materials like cement, fine aggregate (Sand), coarse aggregate, water etc., to site including steel centering, shuttering, labour charges such as weigh batching, machine mixing, laying concrete, lift charges, curing etc., and overheads & contractors profit complete for finished item of work (APSS No. 402 & 403) for Shelves TF

6

-

1818

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Reinforced Cement Concrete M 20 design mix using 12mm size hard granite machine crushed graded metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry, using a minimum quantity of 350 kgs. of cement per 1 cum of concrete using WEIGH BATCHER / MIXER including cost and conveyance of all materials like cement, fine aggregate (Sand), coarse aggregate, water etc., to site including steel centering, shuttering, labour charges such as weigh batching, machine mixing, laying concrete, lift charges, curing etc., and overheads & contractors profit complete for finished item of work (APSS No. 402 & 403) for Shelves SF

31

-

9052

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Reinforced Cement Concrete M 20 design mix using 12mm size hard granite machine crushed graded metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry, using a minimum quantity of 350 kgs. of cement per 1 cum of concrete using WEIGH BATCHER / MIXER including cost and conveyance of all materials like cement, fine aggregate (Sand), coarse aggregate, water etc., to site including steel centering, shuttering, labour charges such as weigh batching, machine mixing, laying concrete, lift charges, curing etc., and overheads & contractors profit complete for finished item of work (APSS No. 402 & 403) for Shelves FF

39

-

10920

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Reinforced Cement Concrete M 20 design mix using 12mm size hard granite machine crushed graded metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry, using a minimum quantity of 350 kgs. of cement per 1 cum of concrete using WEIGH BATCHER / MIXER including cost and conveyance of all materials like cement, fine aggregate (Sand), coarse aggregate, water etc., to site including steel centering, shuttering, labour charges such as weigh batching, machine mixing, laying concrete, lift charges, curing etc., and overheads & contractors profit complete for finished item of work (APSS No. 402 & 403) for Platforms TF

13

-

7878

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Reinforced Cement Concrete M 20 design mix using 12mm size hard granite machine crushed graded metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry, using a minimum quantity of 350 kgs. of cement per 1 cum of concrete using WEIGH BATCHER / MIXER including cost and conveyance of all materials like cement, fine aggregate (Sand), coarse aggregate, water etc., to site including steel centering, shuttering, labour charges such as weigh batching, machine mixing, laying concrete, lift charges, curing etc., and overheads & contractors profit complete for finished item of work (APSS No. 402 & 403) for Platforms SF

20

-

11660

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Reinforced Cement Concrete M 20 design mix using 12mm size hard granite machine crushed graded metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry, using a minimum quantity of 350 kgs. of cement per 1 cum of concrete using WEIGH BATCHER / MIXER including cost and conveyance of all materials like cement, fine aggregate (Sand), coarse aggregate, water etc., to site including steel centering, shuttering, labour charges such as weigh batching, machine mixing, laying concrete, lift charges, curing etc., and overheads & contractors profit complete for finished item of work (APSS No. 402 & 403) for Platforms FF

21

-

11739

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Reinforced Cement Concrete M 20 design mix using 12mm size hard granite machine crushed graded metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry, using a minimum quantity of 350 kgs. of cement per 1 cum of concrete using Concrete Batching Plant including cost and conveyance of all materials like cement, fine aggregate (Sand), coarse aggregate, water etc., to site including steel centering, shuttering, machine mixing, laying concrete, lift charges, curing etc., and overheads & contractors profit complete for finished item of work (APSS No. 402 & 403) for sill slabs. TF

9

-

76140

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Reinforced Cement Concrete M 20 design mix using 12mm size hard granite machine crushed graded metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry, using a minimum quantity of 350 kgs. of cement per 1 cum of concrete using Concrete Batching Plant including cost and conveyance of all materials like cement, fine aggregate (Sand), coarse aggregate, water etc., to site including steel centering, shuttering, machine mixing, laying concrete, lift charges, curing etc., and overheads & contractors profit complete for finished item of work (APSS No. 402 & 403) for sill slabs. SF

5

-

40700

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Reinforced Cement Concrete M 20 design mix using 12mm size hard granite machine crushed graded metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry, using a minimum quantity of 350 kgs. of cement per 1 cum of concrete using Concrete Batching Plant including cost and conveyance of all materials like cement, fine aggregate (Sand), coarse aggregate, water etc., to site including steel centering, shuttering, machine mixing, laying concrete, lift charges, curing etc., and overheads & contractors profit complete for finished item of work (APSS No. 402 & 403) for sill slabs. FF

5

-

39105

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using Concrete Batching Plant with 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including sales & other taxes on all materials , centering using Casurina Ballies , Bamboos , Wooden Reapers , Runners , Wood Posts , Wall Plates etc., for 60cm wide sun-shades 7.5cm thick at fixed end and 5cm thick at free end with an average thickness of 6.25cm including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete manually, laying concrete, curing, overheads & contractors profit complete etc., but excluding cost of steel and its fabrication charges for finished item of work. (APSS No. 402, 403 & 903). FF

2

-

1260

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using Concrete Batching Plant with 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including sales & other taxes on all materials , centering using Casurina Ballies , Bamboos , Wooden Reapers , Runners , Wood Posts , Wall Plates etc., for 60cm wide sun-shades 7.5cm thick at fixed end and 5cm thick at free end with an average thickness of 6.25cm including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete manually, laying concrete, curing, overheads & contractors profit complete etc., but excluding cost of steel and its fabrication charges for finished item of work. (APSS No. 402, 403 & 903). TF

132

-

79596

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using Concrete Batching Plant with 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including sales & other taxes on all materials , centering using Casurina Ballies , Bamboos , Wooden Reapers , Runners , Wood Posts , Wall Plates etc., for 60cm wide sun-shades 7.5cm thick at fixed end and 5cm thick at free end with an average thickness of 6.25cm including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete manually, laying concrete, curing, overheads & contractors profit complete etc., but excluding cost of steel and its fabrication charges for finished item of work. (APSS No. 402, 403 & 903). SF

100

-

57800

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using Concrete Batching Plant with 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including sales & other taxes on all materials , centering using Casurina Ballies , Bamboos , Wooden Reapers , Runners , Wood Posts , Wall Plates etc., for 60cm wide sun-shades 7.5cm thick at fixed end and 5cm thick at free end with an average thickness of 6.25cm including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete manually, laying concrete, curing, overheads & contractors profit complete etc., but excluding cost of steel and its fabrication charges for finished item of work. (APSS No. 402, 403 & 903). FF

53

-

29256

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using Concrete Batching Plant with 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and sales & other taxes on all materials, centering using Steel scaffolding pipes, jack props, wallers, Foot plates, brackets, steel centering plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, laying concrete, curing etc., and overheads & contractors profit complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402). BEAS SLAB 300MM THK SUMP

44

-

142956

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using Concrete Batching Plant with 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and sales & other taxes on all materials, centering using Steel scaffolding pipes, jack props, wallers, Foot plates, brackets, steel centering plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, laying concrete, curing etc., and overheads & contractors profit complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402). BEAS SLAB 175MM THK SEPTIC TANK

49

-

92855

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using Concrete Batching Plant with 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and sales & other taxes on all materials, centering using Steel scaffolding pipes, jack props, wallers, Foot plates, brackets, steel centering plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, laying concrete, curing etc., and overheads & contractors profit complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402). BEAS SLAB 200MM THK LIFT PIT

33

-

71478

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using Concrete Batching Plant with 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and sales & other taxes on all materials, centering using Steel scaffolding pipes, jack props, wallers, Foot plates, brackets, steel centering plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, laying concrete, curing etc., and overheads & contractors profit complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402). HAUNCHES

4

-

38024

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using Concrete Batching Plant with 20mm size graded machine crushed hard granite metal(coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and sales & other taxes on all materials, centering using Steel scaffolding pipes, jack props, Steel centering Plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete manually, laying concrete, curing, overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402). SLAB 150MM THK FF UN SUPPORTED HT 7.32M

88

-

202752

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using Concrete Batching Plant with 20mm size graded machine crushed hard granite metal(coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and sales & other taxes on all materials, centering using Steel scaffolding pipes, jack props, Steel centering Plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete manually, laying concrete, curing, overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402). SLAB 200MM THK TF

348

-

772212

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using Concrete Batching Plant with 20mm size graded machine crushed hard granite metal(coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and sales & other taxes on all materials, centering using Steel scaffolding pipes, jack props, Steel centering Plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete manually, laying concrete, curing, overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402). SLAB 200MM THK SF

44

-

94204

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using Concrete Batching Plant with 20mm size graded machine crushed hard granite metal(coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and sales & other taxes on all materials, centering using Steel scaffolding pipes, jack props, Steel centering Plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete manually, laying concrete, curing, overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402). SLAB 200MM THK FF

240

-

495120

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using Concrete Batching Plant with 20mm size graded machine crushed hard granite metal(coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and sales & other taxes on all materials, centering using Steel scaffolding pipes, jack props, Steel centering Plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete manually, laying concrete, curing, overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402). SLAB 175MM THK TF

148

-

300292

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using Concrete Batching Plant with 20mm size graded machine crushed hard granite metal(coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and sales & other taxes on all materials, centering using Steel scaffolding pipes, jack props, Steel centering Plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete manually, laying concrete, curing, overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402). SLAB 150MM THK FF

48

-

90576

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using Concrete Batching Plant with 20mm size graded machine crushed hard granite metal(coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and sales & other taxes on all materials, centering using Steel scaffolding pipes, jack props, Steel centering Plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete manually, laying concrete, curing, overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402). SLAB 150MM THK TF

362

-

658840

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using Concrete Batching Plant with 20mm size graded machine crushed hard granite metal(coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and sales & other taxes on all materials, centering using Steel scaffolding pipes, jack props, Steel centering Plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete manually, laying concrete, curing, overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402). SLAB 150MM THK SF

177

-

310458

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using Concrete Batching Plant with 20mm size graded machine crushed hard granite metal(coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and sales & other taxes on all materials, centering using Steel scaffolding pipes, jack props, Steel centering Plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete manually, laying concrete, curing, overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402). SLAB 150MM THK FF

236

-

398132

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using Concrete Batching Plant with 20mm size graded machine crushed hard granite metal(coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and sales & other taxes on all materials, centering using Steel scaffolding pipes, jack props, Steel centering Plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete manually, laying concrete, curing, overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402). SLAB 125MM THK TF

1102

-

1797362

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using Concrete Batching Plant with 20mm size graded machine crushed hard granite metal(coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and sales & other taxes on all materials, centering using Steel scaffolding pipes, jack props, Steel centering Plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete manually, laying concrete, curing, overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402). SLAB 125MM THK SF

1079

-

1694030

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using Concrete Batching Plant with 20mm size graded machine crushed hard granite metal(coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and sales & other taxes on all materials, centering using Steel scaffolding pipes, jack props, Steel centering Plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete manually, laying concrete, curing, overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402). SLAB 125MM THK FF

1086

-

1638774

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using Concrete Batching Plant with 20mm size graded machine crushed hard granite metal(coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and sales & other taxes on all materials, centering using Steel scaffolding pipes, jack props, Steel centering Plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete manually, laying concrete, curing, overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402). ROOF BEAMS un supported ht.7.32m

7

-

126210

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using Concrete Batching Plant with 20mm size graded machine crushed hard granite metal(coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and sales & other taxes on all materials, centering using Steel scaffolding pipes, jack props, Steel centering Plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete manually, laying concrete, curing, overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402). ROOF BEAMS Fourth FLOOR

10

-

141280

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using Concrete Batching Plant with 20mm size graded machine crushed hard granite metal(coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and sales & other taxes on all materials, centering using Steel scaffolding pipes, jack props, Steel centering Plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete manually, laying concrete, curing, overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402). ROOF BEAMS THIRD FLOOR

145

-

1973740

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using Concrete Batching Plant with 20mm size graded machine crushed hard granite metal(coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and sales & other taxes on all materials, centering using Steel scaffolding pipes, jack props, Steel centering Plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete manually, laying concrete, curing, overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402). ROOF BEAMS SECOND FLOOR

105

-

1375290

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using Concrete Batching Plant with 20mm size graded machine crushed hard granite metal(coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and sales & other taxes on all materials, centering using Steel scaffolding pipes, jack props, Steel centering Plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete manually, laying concrete, curing, overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402). ROOF BEAMS FIRST FLOOR

104

-

1308632

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using Concrete Batching Plant with 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and sales & other taxes on all materials, centering using Steel scaffolding pipes, jack props, Steel centering Plates etc. including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete manually, laying concrete, curing , overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402). 200MM THK SIDE WALLS

77

-

256487

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using Concrete Batching Plant with 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and sales & other taxes on all materials, centering using Steel scaffolding pipes, jack props, Steel centering Plates etc. including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete manually, laying concrete, curing , overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402). 175MM THK SIDE WALLS

81

-

249318

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using Concrete Batching Plant with 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and sales & other taxes on all materials, centering using Casurina Ballies, Bamboos, Wooden Reapers, Runners, Wood Posts, Steel Plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete manually, laying concrete, curing , overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402) LINTEL FOURTH FLOOR

1

-

14748

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using Concrete Batching Plant with 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and sales & other taxes on all materials, centering using Casurina Ballies, Bamboos, Wooden Reapers, Runners, Wood Posts, Steel Plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete manually, laying concrete, curing , overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402) LINTEL THIRD FLOOR

26

-

368134

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using Concrete Batching Plant with 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and sales & other taxes on all materials, centering using Casurina Ballies, Bamboos, Wooden Reapers, Runners, Wood Posts, Steel Plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete manually, laying concrete, curing , overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402) LINTEL SECOND FLOOR

17

-

230690

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using Concrete Batching Plant with 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and sales & other taxes on all materials, centering using Casurina Ballies, Bamboos, Wooden Reapers, Runners, Wood Posts, Steel Plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete manually, laying concrete, curing , overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402) LINTEL FIRST FLOOR

11

-

142791

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using Concrete Batching Plant with 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and sales & other taxes on all materials, centering using Steel scaffolding pipes, jack props, Steel centering Plates etc. including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete manually,, laying concrete, curing , overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402). COLUMNS FOURTH FLOOR

16

-

261104

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using Concrete Batching Plant with 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and sales & other taxes on all materials, centering using Steel scaffolding pipes, jack props, Steel centering Plates etc. including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete manually,, laying concrete, curing , overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402). COLUMNS THIRD FLOOR

95

-

1479150

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using Concrete Batching Plant with 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and sales & other taxes on all materials, centering using Steel scaffolding pipes, jack props, Steel centering Plates etc. including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete manually,, laying concrete, curing , overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402). COLUMNS SECOND FLOOR

57

-

844740

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using Concrete Batching Plant with 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and sales & other taxes on all materials, centering using Steel scaffolding pipes, jack props, Steel centering Plates etc. including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete manually,, laying concrete, curing , overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402). COLUMNS FIRST FLOOR

95.6

-

1345092

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and placing of the Design Mix Concrete M 20 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using Concrete Batching Plant with 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and sales & other taxes on all materials, centering using Steel scaffolding pipes, jack props, Steel centering Plates etc. including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete manually,, laying concrete, curing , overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402).

6

-

83274

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using Concrete Batching Plant with 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and sales & other taxes on all materials, centering using Steel scaffolding pipes, jack props, wallers, Foot plates, brackets, steel centering plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, laying concrete, curing etc., and overheads & contractors profit complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402).PLINTH BEAMS

69

-

933708

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using Concrete Batching Plant with 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and sales & other taxes on all materials, centering using Steel scaffolding pipes, jack props, wallers, Foot plates, brackets, steel centering plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, laying concrete, curing etc., and overheads & contractors profit complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402). FOOTING

398.2

-

4312904.2

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and placing of the Design Mix Concrete M 20 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using Concrete Batching Plant with 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and sales & other taxes on all materials, centering using Steel scaffolding pipes, jack props, wallers, Foot plates, brackets, steel centering plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, laying concrete, curing etc., and overheads & contractors profit complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402). PLINTH BEAMS

3

-

40023

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Supply and placing of the Design Mix Concrete M 20 grade corresponding to IS 456 with minimum cement content of 380 kgs per 1 cum of concrete using Concrete Batching Plant with 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and sales & other taxes on all materials, centering using Steel scaffolding pipes, jack props, wallers, Foot plates, brackets, steel centering plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, laying concrete, curing etc., and overheads & contractors profit complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402). FOOTINGS(COMPOUND WALL)

6

-

63840

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Providing Plinth protection with a bed of 100mm thick PCC(1:5:10) using screened sand ,40mm size HB Granite metal and on top of PCC, 20mm thick granolithic concrete flooring with CC(1:1:2) prop.using 6mm to 12mm size graded hard granite machine crushed metal laid monolithically already laid, in alternate panels of size not exceeding 1.5 x 1.5 Mts. and providing 5mm thick glass strips between the pannels and finishing the top surface to required smoothness and slopes including grooves, thread lining as directed by the Engineer - in - charge including cost and conveyance of all materials to site and operational & incidental and labour charges like mixing of cement concrete, laying, curing, lift charges etc., and overheads & contractors profit complete including cost of CC bed for finished item of work. (APSS No.701 & 710).

427

-

369782

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Random Rubble stone masonry in CM (1:8) prop: (Cement: Screened sand) using hard other than granite stones carted from approved quarry including cost and conveyance of all materials like cement, screened sand, water, stones etc., from approved quarry, to site, sales & other taxes on all materials including labour for cutting stones to required size and shape, mixing, of cement, mortar, construction, curing etc.,and overheads & contractors profit complete for finished item of work in foundation and basement. (APSS No. 601 & 615)

196

-

788900

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Filling with carted gravel by manual means in trenches, sides of foundations and basement with initial lead in layers not exceeding 15 cm thick, consolidating each deposited layer by watering and ramming including cost and conveyance of water to work site and all operational, incidental, labour charges, hire charges of T & P etc., and overheads & contractors profit complete for fnished item of work. (APSS NO. 309 & 310)

682

-

313038

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Filling with useful available excavated earth by manual means (excluding rock) in trenches, sides of foundations and basement with initial lead in layers not exceeding 15 cm thick, consolidating each deposited layer by watering and ramming including cost and conveyance of water to work site and all operational, incidental, labour charges, hire charges of T & P etc., and overheads & contractors profit complete for finished item of work. (APSS NO. 309 & 310)

1303

-

256691

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Plain Cement Concrete (1:5:10) (cement: fine aggregate: Coarse aggregate) for foundations and under flooring bed using coarse aggregate 40mm size hard , machine crushed granite from approved quarry including cost and conveyance of all materials like cement, sand, coarse aggregate, water etc. to site, sales & other taxes on all materials and including all charges for machine mixing, laying concrete in foundations and under flooring bed, ramming in 15 cm layers finishing top surface to the required level curing etc.,and overheads & contractors profit complete for finished item of work. (APSS No. 402).

166

-

741522

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Plain Cement Concrete (1:4:8) (cement: fine aggregate: Coarse aggregate) for foundations and under flooring bed using coarse aggregate 40mm size hard , machine crushed granite from approved quarry including cost and conveyance of all materials like cement, sand, coarse aggregate, water etc. to site, including sales & other taxes on all materials and including all charges for machine mixing, laying concrete in foundations and under flooring bed, ramming in 15 cm layers finishing top surface to the required level curing etc., and overheads & contractors profit complete for finished item of work. (APSS No. 402).

111.2

-

519637.6

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Earth work excavation for foundations (Manual Means) of buildings, septic tank, sump, compound wall in ordinary soils and depositing on bank with an initial lead of 10m and depth up to 3m including all operational,incidental, labour charges such as shoring, sheeting, planking, strutting etc., and overheads & contractors profit complete for finished item of work excluding dewatering charges etc., as per SS 20 B(APSS 308)

318

-

77274

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Earth work excavation for foundations (Mechanical Means) for buildings in ordinary soils and depositing on bank for all lifts and with an initial lead of 10m and up to 3m depth including all operational, incidental, labour charges such as shoring, sheeting, planking, strutting etc., and overheads & contractors profit complete for finished item of work excluding dewatering charges etc., as per SS 20 B(APSS 308).

1646

-

195874

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Conveyance of un-useful excavated earth to a distance of 5 KM for disposal including hire charges of T & P, labour charges etc., and overheads & contractors profit complete for finished item of work.

615

-

66420

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Dismantling, clearing away and carefully stacking useful materials for re-use and disposal of unserviceable materials with 100m lead as directed by Executive Engineer duly taking actual premeasurements before dismantling including all labour charges, overheads & contractor profit etc., complete. Reinforced cement concrete

122

-

435662

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Dismantling, clearing away and carefully stacking useful materials for re-use and disposal of unserviceable materials with 100m lead as directed by Executive Engineer duly taking actual premeasurements before dismantling including all labour charges, overheads & contractor profit etc., complete.Stone masonry Basement wall

78

-

54210

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Dismantling, clearing away and carefully stacking useful materials for re-use and disposal of unserviceable materials with 100m lead as directed by Executive Engineer duly taking actual premeasurements before dismantling including all labour charges, overheads & contractor profit etc., complete. Brick masonry

410

-

111930

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Dismantling, clearing away and carefully stacking useful materials for re-use and disposal of unserviceable materials with 100m lead as directed by Executive Engineer duly taking actual premeasurements before dismantling including all labour charges, overheads & contractor profit etc., complete. Kadapa slabs or shahabad stone slabs on sand bed

508

-

6096

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Dismantling doors, windows and clear storey windows, Ventilators etc., (wood or steel) shutters including Chowkhats, architraves, hold fasts and other attachments etc., and stacking them within 100m lead including labour charge etc., and overheads & contractors profit complete for finished item of work. Exceeding 3 sqm area

17

-

5457

... More
Upgradation of (30) bedded PHC to (100) bedded Hospital at CHC Korutla;Dismantling doors, windows and clear storey windows, Ventilators etc., (wood or steel) shutters including Chowkhats, architraves, hold fasts and other attachments etc., and stacking them within 100m lead including labour charge etc., and overheads & contractors profit complete for finished item of work. Not exceeding 3 Sqm

31

-

7409



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.