For getting the details of etenders, if you are looking for information about them from the cumbersome government websites but are tired of doing so, Bidassist comes up with a one stop solution. It collates every Eproc telangana tender on Bidassist. One can approach it for the bidding process, registration process, etc., are explained below.

South Central Railway - SCR Tender

Works
Civil And Construction
Road Construction
Civil Works Others
Ireps
+10Anantapur, Andhra PradeshY.s.r., Andhra PradeshPrakasam, Andhra PradeshVellore, Tamil NaduChittoor, Andhra PradeshYadgir, KarnatakaBallari, KarnatakaRaichur, KarnatakaChittoor, Andhra PradeshKalaburagi, Karnataka
Opening Date2 Aug 2024
Closing Date23 Aug 2024
Tender Amount₹ 3,51,69,993.67 
Notes
Download

Costs

Summary

(1) S & T Works In Connection With The Costruction Of Rub's In Lieu Of Interlcoked L.c.nos.2 (kqa Yard), 162 (bmh-rgm),

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply of hylam , resin bonded, 3 mm thick, grade P3, to IS Specification IS: 2036 of 1974 or latest and size 2400mmX600mm of colour approved by site in-charge. Inspection by Consignee.

27

1289

34803

... More
Supply of terminal block 1 way PBT 60mm as per RDSO Drg.No. SA.23745/Alt.5 & IRS S.75/91 & IRS.S.23 with latest amendment. Inspection by RDSO.

390

61

23790

... More
Supply of terminal block 6 way PBT 25mm as per RDSO Drg.No. SA.23756/Alt.3 & IRS S.75/2006(Rev.2) & IRS.S.23 with amendment no.2 or latest. Inspection by RDSO.

790

285

225150

... More
Supply of Non-deteriorating type of fuse holders & fuse links - electric fuse for Railway signalling 8 Rate (in Rupees)d voltage 240 AC/DC to Specn. No. IRS S.78/92 (IRS-S-78/97 Tentative) IS:13703 (part 2/sec2):1993 suitable for E1 fuse 20Amps SC-20 Holder Safe Clip / knife edge type size E1 (R-SS) amp. Fuse links 1/6/10/16 Amps. Inspection by RDSO.

1220

21

25620

... More
Supply o f PVC insulated wire copper conductor 16/02mm to ATC IS:694 to RDSO specification no.IRS.S76/89. Each coil of 100 mts length. To be procured from RDSO approved firms. Inspection by RDSO. The unit numbers means per COIL.

217

797

172949

... More
S u p p l y o f P V C insu la ted wire multi-strand copper conductor 10 Sq.mm flexible Specn.IRS.S76/89.Amendment No.2 or latest. Each coil of 100 mts length. To be procured from RDSO approved firms (size 140/0.3mm). Inspection by RDSO. The unit numbers means per COIL.

53

9390

497670

... More
Supply of PVC wire coils of size 28/03 multi strand (flexible). Specn.IRS.S76/89.Amendment No.2 or latest. Each coil of 100 mts length. To be procured from RDSO approved firms. Inspection by RDSO. The unit numbers means per COIL.

65

1635

106275

... More
Supply of Universal locks with one key for every ten locks. Inspection by Consignee.

580

60

34800

... More
Supply of DWC pipe of 180 mm outer dia/ 153 mm inner dia in lengts of 6 Mtr with coupler. to IS specification No.14930 Part-II.The IS spec shall be marked on the pipe. Inspection by Consignee.

160

2640

422400

... More
Supply of Thermo shrinkable jointing kit as per Spec. No. IRS TC. 77/2010(Rev 2) for all types joints suitable for 6 Quad Jelly filled UG cable. Inspection by Consignee.

127

1923

244221

... More
Supply of desk type 2 wire , 12 way DTMF selective calling group telephone complete as per specification IRS. TC. 80-2000 with suitable power supply unit. Inspection by Consignee.

70

6282

439740

... More
Supply of HDPE telecom duct with outer diameter of 40mm and inner diameter of 33mm 16 permanently lubricated as per Specn. No. RDSO/SPN/TC/45/2006 Revision 1.0 or latest or as per specification TEC GR No.G/CDS-08/02,NOV 2004 or latest . HDPE pipe shall be supplied along with 4mm dia polypropylene rope of approved quality inside wherever required. The length of HDPE telecom duct should be 1 KM. End plugs to be provided along with drum (free of cost) (2 No. per Km.). Inspection by Consignee.

6.5

45226

293969

... More
Supply of one quad V.F. Transformer assembly (2T) to RDSO Spec. No. IRS: TC. 76 -2000 with Amdt.1 (or latest) with impedance ratio 470:1120 Ohms. Inspection by Consignee.

90

707

63630

... More
Supply of emergency socket six pin flat with 6 pin suitable plug as per RDSO spec No IRS TC.42/87.Amd.1 or latest. Inspection by Consignee.

50

273

13650

... More
Supply of portable true RMS multi meter with AC + DC measurements RISH 18S, IR model with 43/4 digital display automatic terminal blocks system auto power off automatic date hold true RMS should have the following specifications. (i) AC and DC voltage: Up to 1000 volts. (ii) AC and DC current: Up to 10 Amps (iii) input 19 impedance: 10m ohms (approx.) (iv) Resistance: 30m ohms (with lead resistance) (v) Frequency: 100 k Hz (vi) capacitance: 10000 micro farad (vii) db measurement exit counting stop watch facility. (viii) AC+DC measurements high accuracy 1 second response/time off beeper, over load warning/low voltage battery indicator, continuity test facility with sound signal capable of reads with the following spares. (ix) Test probe set installed dry batteries - 2 No. A1.5v alkaline batteries installed fuse 5A, 100V rMS copy of for used manual in English, test with neat rubber holster with tilt stand and carrier strap, warranty card, 1 set of extra fuses. Inspection by Consignee.

2

13570

27140

... More
Supply of Four Wire DTMF way station equipment to RDSO spec. No. TC - 60/ 2007-Amdt-1 (or latest) with telephone to RDSO spec. No.TC-38 /97 (or latest). Inspection by Consignee.

20

3833

76660

... More
Supply, painting and fixing of cable Gland Plate for Full GKP Box as per site requirement ( required bolts and nuts for fixing the gland plates are to be arranged by the contractor). Inspection by Consignee.

66

533

35178

... More
Supply of KUSUM MECO KM-2006 3.6AC/DC TRMS LEAKAGE CLAMP METER Digital multimeter. Inspection by Consignee.

2

21400

42800

... More
"Supply of 4 wire station control Telephone to RDSO Spec. IRS. TC - 38/97(Amndt.2) or latest of make Tummala/Bentron/Epsilon or equivalent. Inspection by Consignee.

85

2124

180540

... More
Supply of Master Telephone with Voice logging facility for Electrnoic L.C.Gate Telephone system as per specification no.RDSO/SPN/TC-51/2011 Revision 3.0 with amedment -1 or latest. Make/Brand - EPSILON, Bentron, Sirveen or similar. Inspection by Consignee.

1

50999

50999.6

... More
Supply of Electrnoic LC Gate Slave telephone system with voice recorder as per RDSO/SPN/TC/51/2021 Revision 1.0. Inspection by Consignee.

6

5298

31789.2

... More
Supply of Centralised power supply system 24 volts DC power pack with 7AH MF battery for Electronic LC Gate telephone system as per RDSO Spec No. RDSO/SPN/TC/51/2011 (Rev-3.0) Amdent-1 or latest. Inspection by Consignee.

6

7434

44604

... More
Supply of 4 Wire/ 2 wire train traffic control equipment with dual tone multi frequency (DTMF) signalling as per RDSO specification no. IRS-TC - 60 /2007 or latest. Inspection by Consignee.

15

17995

269925

... More
"Supply of fixed 4G wireless phone to support quad band GSM (4G FCT/FWP Phones with VOLTE facility of make Beetel/Visiontek/Motorola)". Inspection by Consignee.

50

4097

204872.5

... More
"Supply of subscriber card (FXS card) to suit PD Mux of WEBFIL make as per RDSO spec.IRS-TC- 68/2012 or latest. Firm's accepted offer: 2W subscriber interface card 4 Channels per card compatible with WEBFIL make PD MUX as per latest spec." Inspection by RDSO.

14

44572

624009.96

... More
Supply of tributary card for 2MB programmable primary digital drop insert multiplexer (PD MUX) as per spec.No.IRS.TC/68/12 with latest amendment of WEBFIL make. Inspection by RDSO.

14

49122

687711.08

... More
Supply of Network Interface Module(NIM) for 2MB porgrammable PD MUX as per pec.No.IRS/TC/68/12 with latest amendment of WEBFIL make. Inspection by RDSO.

15

31691

475368.9

... More
Supply of Power Supply Unit (PSU card) for WEBFIL PDMUX. Inspection by RDSO.

15

29505

442588.5

... More
"Supply of E & M card for Webfill 2MB programmable PD MUX as per spec. IRS/TC/68/2012with latest amendment (Make: Webfill). " Inspection by RDSO.

25

33124

828124

... More
Supply of Unmanaged Ethernet switch with 6 10/100 Base T(X) ports, and 2 100 Base FX single- mode ports with SC connectors, Operating temperature : -40 to 75A?C of M/s MOXA make or equivalent. Inspection by Consignee.

8

67260

538080

... More
Supply of fan less embedded industrial grade computers ( Similar to Moxa V2406 or better ) with all accessories such as key board, mouse, antivirus etc. of industrial grade s per approved specification as recommended by RDSO (TAN No. STS/TAN/3007 Version 1.0 or latest). Inspection by Consignee.

4

257250

1029000

... More
Supply of commercial grade operator VDU of size 55" Full HD, HDMI/DVI Connectivity, Inbuilt Speaker etc. Inspection by Consignee.

2

226320

452640

... More
Supply of 2W Exchange Loop interface card (4 circuits per card) as per RDSO specification No. IRS.TC/68/2012 Webfil Make. Inspection by RDSO.

7

38766

271365.78

... More
Supply of 12V-42AH maintenance free lead acid battery. Inspection by Consignee.

20

2740

54810

... More
Supply of sealed Lead Acid cells MF12V/7AH make Exide CS7-12 orsimilar. Inspection by Consignee.

50

721

36050

... More
Supply of Mother Board (AZLM) for MSDAC of ELDYNE make as per RDSO Specn No. RDSO/SPN/ 176/2013 or latest. Inspection by RDSO.

2

48979

97958.88

... More
Supply of Analog card (AzLM) for MSDAC of ELDYNE make as per RDSO Specn No. RDSO/SPN/ 176/2013 or latest. Inspection by RDSO.

3

163666

490998

... More
Supply of Serial card for MSDAC of Eldyne make as per RDSO spec. RDSO/SPN/176/2013 Ver.-3 or latest. Inspection by RDSO.

2

76551

153102

... More
Supply of Parallel card for MSDAC of Eldyne make as per RDSO spec. RDSO/SPN/176/2013 Ver.-3 or latest. Inspection by RDSO.

4

65189

260756

... More
"supply of cable Route Locator Model: seekTech sR-20 of RIDGID make, set consists of seek TeJt SR.20 receiver with 5 watts cable line transmitter seek tech ST-305 with the following specification and suitable rechargeable cells, chargers 03 Nos with suitable carrying case. l,Target line and guidance arrow euickly identify 24 distortion' 2.proximity signal and signal strength help work through difficult locates. 3.trace any frequencies from 10HZ to 35 KHZ. 4.Active live trace frequencies from 1OHZ to 35 KHZ. S.passive power trace 50H2,6 O{Z<4K{Zbroadband. 6.passive Radto trace 4KHZ - 15KHZ -36KKHZ. T.sound frequencies 16H2, 51z3HZ, 640H2, gso{Z, SKHZ, 33KHZ8'pol,Ier source 4C Cell batteries included. 9.30 user definable frequencies can be set from l0 HZ to 35 KHZ." Inspection by Consignee.

1

375000

375000

... More
Supply of CPU Card-1 for HASSDAC Spec RDSO/SPN/177/2012(Ver.3) GGTRONICS make. Inspection by RDSO.

2

61894

123789.08

... More
Supply of CPU Card-2 for HASSDAC Spec RDSO/SPN/177/2012(Ver.3) GGTRONICS make. Inspection by RDSO.

2

61894

123789.08

... More
Supply of COM-1 Card for HASSDAC Spec RDSO/SPN/177/2012(Ver.3) GGTRONICS make. Inspection by RDSO.

4

27859

111439.2

... More
Supply of COM-2 Card for HASSDAC Spec RDSO/SPN/177/2012(Ver.3) GGTRONICS make. Inspection by RDSO.

4

27859

111439.2

... More
Supply of DC-DC Convertor Card for HASSDAC Spec RDSO/SPN/177/2012(Ver.3) GGTRONICS make. Inspection by RDSO.

2

38232

76464

... More
Supply of PD-1(21Khz) Card for HASSDAC Spec RDSO/SPN/177/2012(Ver.3) GGTRONICS make. Inspection by RDSO.

5

41878

209391

... More
Supply of PD-2(25Khz) Card for HASSDAC Spec RDSO/SPN/177/2012(Ver.3) GGTRONICS make. Inspection by RDSO.

5

41878

209391

... More
Supply of Reset Box for HASSDAC Spec RDSO/SPN/177/2012(Ver.3) GGTRONICS make. Inspection by RDSO.

2

38673

77346.64

... More
Supply of System Card for "Universal Fail Safe Block Interface (UFSBI) equipment as per RDSO Specn No.IRS S-104/2012 of Webfil Make. Inspection by RDSO.

4

33119

132476.24

... More
Supply of Communication Driver Card for "Universal Fail Safe Block Interface (UFSBI) equipment as per RDSO specn No.IRS S-104/2012 of Webfil Make. Inspection by RDSO.

4

38783

155132.24

... More
Supply of Input Card for "Universal Fail Safe Block Interface(UFSBI) equipment as per RDSO Specn No.IRS S-104/2012 of Webfil Make". Inspection by RDSO.

4

17368

69473.68

... More
Supply of Feedback Card for "Universal Fail Safe Block Interface(UFSBI) equipment as per RDSO Specn No.IRS S-104/2012 of Webfil make". Inspection by RDSO.

4

17368

69473.68

... More
Supply of Output Card for "Universal Fail Safe Block Interface(UFSBI) equipment as per RDSO Specn No.IRS S-104/2012 of Webfil Make". Inspection by RDSO.

4

32645

130583.52

... More
Supply of PSU Card for "Universal Fail Safe Block Interface (UFSBI) equipment as per RDSO Specn No.IRS S-104/2012 of Webfil make". Inspection by RDSO.

4

49829

199316.16

... More
Supply of Display Card with Reset Box for "Universal Fail Safe Block Interface (UFSBI) equipment as per RDSO Spec No.IRS S-104/2012 of Webfil Make". Inspection by RDSO.

2

26734

53468.16

... More
Supply of Back Plane for "Universal Fail Safe Block Interface (UFSBI) equipment as per RDSO Spec No.IRS S-104/2012 of Webfil Make". Inspection by RDSO.

2

49089

98178.36

... More
Supply of Alarm Extender Card for "Universal Fail Safe Block Interface (UFSBI)equipment as per RDSO SpecNo.IRS S 104/2012 of Webfil Make". Inspection by RDSO.

2

43313

86626.16

... More
Supply of Wireless N ADSL2+4 Port Gateway with USB as per Technical Specification attached make : - ZYXEL or similar Model :- AMG1312T20A. Inspection by Consignee.

20

1919

38397.2

... More
Supply of 4G GSM modem for networking of RTU Make: Efftronics or Similar. Inspection by Consignee.

40

37170

1486800

... More
Supply of 4G Software for networking of RTU Make: Efftronics or Similar. Inspection by Consignee.

40

11564

462560

... More
Track crossing by horizontal boring method based on the drawing no.DRM/J/6735 dated 7-8-03 3 and as advised by the engineer at site. This includes the supply and insertion(pushing) of GI pipe (80mm) confirming to IS.1239 heavy class in the bore drilled with the coupler between two pipes. All the joints of casing pipes should be tight and leak proof.

580

1403

813740

... More
Trenching under Rails for crossing the track(Track crossing) and refilling of trenches as per RDSO drawing No.SDO/CABLE LAYING /009. The track crossing shall be done at right angles.The depth of cable trench 4 shall be 1.2 Mtr. below the rail flange. The depth between top cable and the level of rail flange of the rail shall never be less than 1.0 Mtr.. The ballast shall be Stored separately while making the trench and the earth soil shall be stored separately. while re-filling the trench, the earth soil has to be filled first to the ground level and the ballast has to be properly put in the track. this work has to be done under supervision of supervisor of S&T and supervisor of P.Way

1520

141

214320

... More
Laying different type cables in the trench. Termination covered elsewhere.

45500

5

227500

... More
Supply & Laying of G.I Pipes 100mm dia. medium quality to specification IS.1239 (part-I) 1990 and 6 galvanised to specification IS.4736-1986 On bridges , culverts, trench with channel ramps on either end of the culvert/bridges. Clamping arrangement with MS brackets for fixing of GI pipes on bridges/culverts, small holes of 5mm are to be drilled on the pipe before laying of the pipes. Inspection by Consignee.

690

341

235290

... More
Provision and laying in position cement concrete of 1 cement:3 sand:6 graded stone aggregate of 20mm normal size excluding cost of cement, centering and shuttering ( including transportation of all the material) - Plain cement Concrete of 1 cement: 3 sand : 6 graded stone aggregade 20mm nominal size.

97

2085

202265.37

... More
Provision and laying in position cement concrete of 1 cement:3 sand:6 graded stone aggregate of 20mm normal size excluding cost of cement, centering and shuttering ( including transportation of all the material) - Cement 53 grade (@ the Rate (in Rupees) of 2.2 quintals per Cum of concrete.

120

460

55200

... More
Provision and laying in position cement concrete of 1 cement:3 sand:6 graded stone aggregate of 20mm normal size excluding cost of cement, centering and shuttering ( including transportation of all the material) - Centering and shuttering.

220

291

64053

... More
Foundations, erection, fixing of ' E' type locks, painting the box and painting of termination & other 10 particulars of the following boxes . Metal Size of the aggregate should not be more than 40mm. Work to be done as per prescribed drawing no.SK/CN/1/89-A & B- All the material is to be arranged by the contractor except E- type lock ( E-type lock will be supplied by Rlys) - for Full GKP Boxes

52

2460

127920

... More
Supply and fixing of teak wood reapers suitable for Full location Box with 50 mm width x 20mm thick and length of 940mm after applying two coats of wood primer. The unit numbers means per reaper.

416

130

54080

... More
Supply and fixing of teak wood reapers suitable for Full Box 75mm width x 20mm thick and length of 940mm after applying two coats of wood primer. The unit numbers means per reaper. Per

124

159

19716

... More
Numbering location box as per standard practice and writing all termination particulars inside the location box as per details. This includes all main and tail cable particulars, writing of cable numbering of cables, polishing teak wood boards in two coats and painting hard wood shelves in two coats of black enamel.

84

280

23520

... More
Excavation of earth and providing earth pipe of size 50mm dia, 3.5mm thick 2.0 m. long G.I. pipe with masonry tub constructed around at earth locations as specified by site Engineer. Alternate layers of 30kgs- 15 char coal and 30kgs-common salt to be filled in the pit while closing. The pipe perforation etc., to be carried out as per drawing No. G/SG/09/2002. The earth pipe to be connected to the function with cable as supplied by Railways. The reading should be painted on the masonry tub. The masonry tub of 300X300X300mm should be covered with cement slab. ( All materials to be supplied by the contractor except cable.)

110

1406

154660

... More
Earthing and soldering of the cable armours. The unit numbers means per cable.

804

21

16884

... More
Foundation, erection , wiring, painting testing and commissioning of Colour light signal 2/3/4 17 aspects including dependent shunt signal as per drawings of Drg.no.SC//N/CN / 62 /A. Implantation distance writing. For foundation 1 cement: 3 sand : 6 aggregate shall be used .Size of metal aggregate not more than 40mm and river sand to be used. Work to be done as per prescribed drawings above. (All the material ,cement ,sand aggregate paint including nuts, bolts, washers required are to be arranged by the contractor.)

13

3783

49179

... More
Strengthening of foundations of signals, Full/Half location boxes, by carrying out the earth work around the foundation, ramming of the earth, caring out masonry work from bottom of earth work using country stones and cement masonry to prevent the earth from slipping down the bank.

96

2813

270048

... More
Fixing relay bases on the relay frames erected in Relay Room, Wiring of all types of relays by drawing various sizes of wires/multicore cable, fixing fuses, condensers, resistances, LEDs etc and wiring duly soldering the same as per approved circuit diagram, testing point to point before soldering and after soldering, bunching and lacing as per detailed technical specification.Different colour codes and sizes of wire to be used as per standard practice. This also includes, provision of all PVC sleeves required to be provided. Copper lugs to suit 19 to 16/02 wire and neat bunching, lacing with Modi Nylon / Twine thread and using PVC dotted tape with buttons were required. This also includes soldering all the wires in the relay room with Rosine core of IS Spec. 1921 ( 60 % Tin and 40% Led). Soldering should be done as per standard practice. This also includes inserting the clips, point to point testing as per the circuit diagram and plugging relays to Relay bases (except Inter-cables, relays other materials such as Rosine core, flux, nylon thread. PVC dotted tape should be supplied by the contractor). Point to point testing should be done in the presence of Engineer-in-charge as instructed in two stages, one before soldering and the other after soldering.

315

174

54810

... More
Non Interlocking arrangements

13

12300

159900

... More
Transportation of materials from any Stores to Site and vice-versa including loading and unloading. Lead above 50Kms. The unit numbers means PTPK.

63200

4

303360

... More
Arranging of sufficient staff by contractor and giving test to the railway incharge in the following stages as per instructions - Stage -1 : testing of wires drawn point to point using buzzer. (Before and after soldering.) .

250

316

79000

... More
Arranging of sufficient staff by contractor and giving test to the railway incharge in the following stages as per instructions - Stage -II : Making a simulation test board plywood 3mm approximately size 23 1.5x1meter. Painted according to the yard layout fixing 1 way /2 way switches in its approximate position for track circuit , point setting lamp holders and lamps. Carrying out testing using simulation board after energising of internal circuit. Commissioning of indoor and outdoor equipment as laid down in technical specification. The unit numbers means per ROAD. .

15

2686

40290

... More
Releasing of location boxes Full/Half/sheet iron

82

148

12136

... More
Releasing of Warning Boards/stop boards

25

252

6300

... More
Straight through / derivation with/without transformer joints: Installation Thermo shrinkable jointing kits for straight through / derivation joints for LC gate, pump houses etc where VF transformers are not required 28 and derivatin joint by using 2T trasformer ( to be housed in the joint) . This includes tapping of nominated Quad at a specific location shown by the Railway Engineer at site to the jelly field cable already laid. All material including valco tapes except thermo shrinkable jointing kit shall be supplied by the contractor. The unit numbers means per JOINT.

85

979

83215

... More
Laying of HDPE duct 40/33 mm dia in the trenches and in protective works already provided.

6.5

4956

32214

... More
Supply and Installation of OFC joint enclosure and splicing of Optic fiber cable (24 fibres) and 31 testing as per technical specification No. GR OJC-2/02 Sept 2003. Supply of Splice Enclosure (24 fiber) shall be of TVS make Part No.1500-L18X-XX as per Board specification of TEC and Schedule of supply enclosed. All materials including Fusion splicing machine used for fiber splicing and, OTDR for testing and other testing materials if any shall be arranged by the contractor

34

6416

218144

... More
Excavation of Jointing pit and provision of joint chamber of 1.2Meter dia. Of 60 cm height with 2- 32 piece cover on top and bottom cover with holes for drainage (reinforcement drawing will be as per technical specification).This includes water cooling of chamber, backfilling and ramming of the trench after cable laying and consolidation of soil as well as disposal of soil as per plan as advised by site engineer.

34

3745

127330

... More
Erection, wiring, painting, testing and commissioning of Junction type/direction type/stencil type/multi lamp type route indicators 1/2/3/4 /5/6 way. The unit numbers means per Route.

1

299

299

... More
Erection, wiring, painting, testing and commissioning of Calling on Signal/post type shunt signal

1

236

236

... More
Fabrication, Supply and fixing of CALLING ON instruction boards, STOP boards with engineering 35 grade reflective sticker of size 600X900X1200 mm GI sheet, with MS angle of 75X75X6 mm with 6 me-ter length including paint, excavation of pit and concrete foundation etc..as per the instructions of sight in-charge. All necessary materials to be arranged by the contractor).

2

3549

7098

... More
Taking copies of approved circuit diagrams/drawings issued by the Railways on ammonia printing paper. (A-2 size.) - including supply of ammonia paper. The unit numbers means Each sheet of A2 size.

1000

7

7000

... More
"Supply & Installation of control console with driver/convertor unit HP pavilllion Ryzen 5 Quad core 1 3550H - 8GB/1TB HDD/Windows 10 Home/4GB graphics/ NVIDIA GeForce GTX 1650 Laptop of 15.6 inch Full HD LED backlit display & pre installed genuine latest windows perating system of make HP or Lenovo or Dell or reputed make. (Inspection by consignee)."

2

59990

119980

... More
Printing of drawings on 100 GSM paper of A2 size sheet..

2550

45

114750

... More
Connecting the cables to existing location box by breaking the location box foundation.

230

320

73600

... More
Excavation of pit, casting concrete foundation and erection of apparatus case full size.

4

9875

39500

... More
Transporting and supply and installation of Concrete (RCC) route indicators at intervals of 50 meters as per technical specification. They should be of standard RCC with letters "one side "SCR" and the other side "S&T Cables". In case of telecom quad cable joint locations, it shall be painted with red colour.

20

807

16140

... More
Provision of Security Guards round the clock beat from Up Home Signal to Down Home Signal to avoid theft of signalling amenities in 12 hour shift. (Per Unit= Per 12 Hours)

500

434

217000

... More
Providing the services of Computer oriented technical manpower to carryout works like drawing,computation ,write up etc., Using computer, Using software like AUTOCAD,MS office etc., between 08.00 7 Hrs and @ 20.00Hrs of the day with all expenses of transportation, accommodation, food, consumables etc., with all ascents, descents, taxes, octroi, cess, fees, duties with contractors cost etc., as per special condition /specifications / regulations and as directed by Engineer-in-charge. Note: The person engaged for providing the services shall be convergent with computer working knowledge in above softwares

600

550

330000

... More
"Inter Connecting cables, terminals, mounting arrangements, fixtures and accessories to make EI 9 system functional. Alteration to application logic to suit modified SIP of Closure of L.C.No.162 between BMH-RGM stations of Make M/s Kyosan. Alterations to existing interface circuit diagram to suit modified SIP of closure of L.C.No.162 between BMH-RGM stations. Factory acceptance Test of EI system. Site Acceptance test of EI system. Installation, testing & Commissioning of EI system to suit modified SIP".

1

2475229

2475229

... More
Provision for EI alterations. This includes (a) interconnecting cables, connectors, terminals, mounting arrangements, fixtures & accessories to make EI system alteration functional (b) alteration of existing 10 application logic programme to suit modified SIP (c) alteration to existing interface circuit diagram to suit modified SIP (d) factory acceptance test of EI system (e) site acceptance test of EI system and (f) installation, testing & commissioning of EI system as per modified SIP.((a) closure of LC.159 between CLPE - TU stations, (b) closure of LC 123A between HX-KPU stations and (c) closure of LC 154 at RLL yard).

3

3660000

10980000

... More
Supply and Installation of OFC & E1 Integrated Device with OFC ports & STM interlinking Interface. Make/Brand - TEAMLINK FABIO 2CX.

2

87320

174640

... More
"Fabrication, supply and erection of conventional Earth to signaling equipments -Excavation of earth and providing earth pipe of size 50mm dia, 3.5mm thick 2.0 m. long G.I. pipe with masonry tub constructed around 12 at earth locations as specified by site Engineer. Alternate layers of 30kgs-chrcoal and 30kgs-common salt to be filled in the pit while closing. The pipe perforation etc., to be carried out as per drawing No. SK 10/10.. The earth pipe to be connected to the function with cable as supplied by Railways. The reading should be painted on the masonry tub. The masonry tub of 400X400X450mm should be covered with cement slab. ( All materials to be transported and supplied by the contractor except cable.)"

70

5100

357000

... More
Testing & commissioning of 4G GSM modem for networking of RTU & its software.

40

7080

283200

... More
Hiring of skilled labour (one man day = one shift of 08 hours)

300

695

208500

... More
Hiring of unskilled labour (one man day = one shift of 08 hours)

500

494

247000



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.