South Central Railway Tender

For getting the details of etenders, if you are looking for information about them from the cumbersome government websites but are tired of doing so, Bidassist comes up with a one stop solution. It collates every Eproc telangana tender on Bidassist. One can approach it for the bidding process, registration process, etc., are explained below.

South Central Railway - SCR Tender

Works
Telecommunication Services
Ireps
Opening Date23 Dec 2023
Closing Date5 Feb 2024
Tender Amount₹ 84,25,65,337 
Notes
Download

Costs

Summary

Comprehensive Signal And Telecommunication Works For Provision Of Automatic Signalling works In Sirpur Kaghaznagar

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply of CLS ladder set complete with staging, supports, signal number plate, cast iron ladder base to suit 3.5 Metre post as per drg.no.SA.23150.S.2033. (Inspection : RITES)

106

3574

378844

... More
Supply of Surface base 140mm dia.post to suit item no. 1 & 2 as per drg.S.2011/M (Inspection : RITES)

122

2370

289140

... More
Supply of Offset bracket to suit 140mm dia. CLS post with two numbers of U bolts and nuts complete (Inspection : RITES)

24

3377

81048

... More
Supply of Calling On signal unit complete and U bolts to drawing no.SA.24381 /Adv. (Inspection : RITES)

50

3242

162100

... More
Supply of position light shunt signal ground type complete with base , Pipe, hoods, wire mesh, lenses, Number plate lamp holders, terminal block to Drg.No.S23840/Alt.1/Latest.(Inspection by RITES)

5

4160

20800

... More
Supply of position light shunt signal Post type with hoods, lenses, Number plates, lamp holder, wire mesh and terminal block and offset bracket to suit 90mm sockets (CLS) with 2 Nos of 'U' Bolts and nuts complete to fix calling 9 on signal/ shunt signal below main stop signal as per to Drg.No.S23840 / Latest. (Inspection by RITES)

50

2416

120800

... More
Supply of Junction type/Directional type route indicator 1 way to drawing no.SA.23402 with IRS - S 66/84 with amendment-1 (Inspection : RITES)

2

10591

21182

... More
Supply of Junction type/Directional type route indicator 2 way to drawing no.SA.23402 with IRS - S 66/84 with amendment-1 (Inspection : RITES)

27

19110

515970

... More
Supply of GKP type Location Boxes Full size as per drg. No. S&T/MFT/2378 (Single) (Inspection : RITES)

500

8960

4480000

... More
"Supply of hylam , resin bonded, 3mm thick, grade P3, to IS Specification IS: 2036 of 1974 orlatest and size 2400mmX600mm of colour approved by site in-charge.(Inspection by Consignee)"

20

1289

25780

... More
Supply of relay fixing frame for Full location box, the frame should be made out MS angle of 25mm X 25mm X 3mm and approximate size of 940mm X 150mm with suitable holes to fix the same in the box. (Inspection : RITES)

250

591

147750

... More
Supply of Track lead junction boxes fiber glass as per Drg.No.CWM-00597of F.R.P material to IRS.S.23 specification along with fixtures i.e., on MS angle 50x50x5mm, 0.9 Meters long two numbers of G.I. pipes of 25mm dia. along with nuts and bolts and 500mm long (this includes gromite bushes, 60mm PBT terminal). (Inspection by RITES)

50

1057

52850

... More
Supply of track feed regulating resistance disk type 0 to 30 Ohms as per Drg. No. SA. 20161/66/M or latest. To be procured from RDSO approved firms. (Inspection by RDSO)

50

243

12150

... More
Supply of B type chokes to specification no.IRS-S.65/83 to amendment no.1 or latest. (Inspection by RDSO)

25

1604

40100

... More
Supply of relay Plug-in-type, Style AC LED all aspects, AC Lamp proving relay unit with in-built current 18 transformer type, slow release neutral line relay,4F.4B contacts, front and back contacts metal to carbon, shall be suitable for working in series with the 110V AC, LED signal lamp rate ( in Rupees)d at 15W confirming to RDSO spec. STS/E/relays/AC lit LED signal/09-2002, BRS 941A,IRS:s34 & IRS:S23 (as applicable). The interlocking code for this unit shall be ABDHK.(with ATC clips) (Inspection by RDSO)

500

4831

2415500

... More
Supply of AC immune, plug-in-type, Style 'QTA2' DC Neutral track, 9 ohm, 2F.1B contacts, front and back 19 contacts metal to carbon, complete with plug-board, retaining clip and connectors conforming to BRS: 939A, BRS: 966 (Appendix F2), IRS:S 34 & IRS:S 23 (as applicable). The interlocking code for this unit shall be FGHKX.(with ATC clips) (Inspection by RDSO)

20

3271

65420

... More
Supply of Relay Non-AC immune, plug-in-type Style 'QN1, DC neutral line, 24V, 8F.8B contacts, front and back contacts metal to carbon with plug board retaining clip and connectors confirming to BRS 930, IRS-S34, IRS-S23 (as applicable). The interlocking code for this unit shall be ABCDF.(with ATC clips) (Inspection : RDSO)

2000

2992

5984000

... More
Supply of relay, Non-AC immune plug in type, style QN1, DC neutral line, 24V, 12F/4B contacts, front and back contacts metal to carbon with plug board, retaining clip & connectors conforming to BRS:930, IRS: S 34 & IRS:S 23 (as applicable). The interlocking code for this unit shall be ABCDE (with ATC clips).(Inspection by RDSO)

500

2930

1465000

... More
Supply of Relay AC immune, plug-in-type Style 'QNA1, DC neutral line, 24V, 8F.8B contacts, front and back contacts metal to carbon with plug board retaining clip and connectors confirming to BRS 931A, IRS-S60, IRS-S34 and IRS-S23 (as applicable). The interlocking code for this unit shall be ABDGH.(with ATC clips)(Inspection by RDSO)

1000

3173

3173000

... More
"Supply of WAGO Terminal as per RDSO Specification No. 189/2004 which consists as per following: a) 2 23 Conductor disconnect type terminal block as per Model No. 280-870 -- Qty: 6 No. b) End plate type 280-374 suitable for disconnect terminal of Model No.280-870 -- Qty: 1 No. c) End stop terminal block type 249-117 -- Qty: 2 No. d) Shorting links (16A) as per model 280-402." (Inspection by RDSO)

4000

486

1944000

... More
SOR No.607(a)Supply of Non-deteriorating type of fuse holders & fuse links - electric fuse for Railway 24 signalling Rate (in Rupees)d voltage 240 AC/DC to Specn. No. IRS S.78/92 (IRS-S-78/97 Tentative) IS:13703 (part 2/sec2):1993 suitable for E1 fuse 20Amps SC-20 Holder Safe Clip / knife edge type size E1 (R-SS) amp. (a) Fuse holder 20A capacity.(Inspection by RDSO)

8000

150

1200000

... More
SOR No.607(b)Supply of Non-deteriorating type of fuse holders & fuse links - electric fuse for Railway 25 signalling Rate (in Rupees)d voltage 240 AC/DC to Specn. No. IRS S.78/92 (IRS-S-78/97 Tentative) IS:13703 (part 2/sec2):1993 suitable for E1 fuse 20Amps SC-20 Holder Safe Clip / knife edge type size E1 (R-SS) amp. : Fuse links 2Amps/6Amps/10Amps/20 Amps/32Amps/40Amps. (Inspection : RDSO)

8000

21

168000

... More
Supply o f P V C insulated w ir e copper conductor 16/02mm to ATC IS:694 to RDSO specification no.IRS.S76/89. Each coil of 100 mts length. To be procured from RDSO approved firms. (Inspection : RDSO) Colour as specified by Engineer In Charge.(Per Unit=coil) (Inspection by RDSO)

2000

797

1594000

... More
Supply and installation of Four channel Earth leakage detectors as per RDSO specification No. 256/2008 to the required configuration as per site incharge directions.(Inspection by RDSO)

12

53628

643536

... More
Supply o f PVC wire coils of size 28/03 multi strand (flexible). Specn.IRS.S76/89.Amendment No.2 or latest. Each coil of 100 mts length. To be procured from RDSO approved firms. Colour to be specified by Engineer in Charge(Per Unit=coil) (Inspection by RDSO)

1000

1635

1635000

... More
"Supply of Battery charger of 230Volts AC / 110V DC 30 Amps single phase, signalling / telecom.Instrument as per RDSO Specn. IRS S.86/2000 Amd.1 or latest.(Inspection by RDSO)"

12

74911

898932

... More
Supply of Data Logger with 512 Digital inputs and 32 Analog inputs for remote monitoring with net work 30 facility of signalling parameters and power supply arrangements to confirming to Specn. No. IRS. S.99/2006 with 64 input digital cord as a spare and fuse monitoring PCBs for monitoring at least 50 No. of 2 Amps Fuses, with inbuilt modem cards for networking, (Inspection : RDSO)

8

383224

3065792

... More
Supply of Universal locks with one key for every ten locks. (Inspection : Consignee)

1000

60

60000

... More
Printing, Binding & supply of the following registers with latest proforma given by in-charge officer each register of 100 pages.. (Inspection : Consignee)(Per Unit=Per register)

200

70

14000

... More
Supply of HDPE telecom duct with outer diameter of 40mm and inner diameter of 33mm permanently 33 lubricated as per Specn. No. RDSO/SPN/TC/45/2006 Revision 1.0 or latest or as per specification TEC GR No.G/CDS- 08/02,NOV 2004 or latest . HDPE pipe shall be supplied along with 4mm dia polypropylene rope of approved quality inside wherever required. The length of HDPE telecom duct should be 1 KM. End plugs to be provided along with drum (free of cost) (2 No. per Km.). (Inspection : RDSO/RITES)

200

45226

9045200

... More
HDPE duct associated accessories and tools as per the specification of NS.1: Plastic couplers - slip fit/ push type for HDPE duct(2 no.per km) (Inspection : Consignee)

1

58

11600

... More
HDPE duct associated accessories and tools as per the specification of NS.1: End plug for HDPE duct (2 no. per km) (Inspection : Consignee)

2

23

9200

... More
HDPE duct associated accessories and tools as per the specification of NS.1: Cable sealing plug for HDPE duct (1 No. per km) (Inspection : Consignee)

3

29

5800

... More
Supply of Krone Termination box 20 pair (Inspection : Consignee)

10

1047

10470

... More
Supply of 12 pair weather proof C.T. Box for station SP/SSP/TSS etc locations (Inspection : Consignee)

20

2462

49240

... More
a) Supply of 15 U rack wall mounted of VERO President make or similar with cooling fan, power manager 39 with 5 sockets,1 equipment tray, earth connecting kit b) Wago terminal one set fitted on DIN rail consist a. part no.280- 101 Qty 32 nos ( terminals) b. part no.280-301 Qty 4 nos ( end plate) c. part no. 249-116 Qty: 8 nos ( end stop) d. part n o. 210-229/PW/11-000 per mtr. e. marking material 1 to 32. (Inspection by Consignee)

12

7620

91440

... More
Supply of double key lock. (Inspection : Consignee)

20

303

6060

... More
Supply of 35 Sq.mm Multi-strand single core PVC insulated copper cable as per IS:694 for connecting Main earth electrode to MEEB in the equipment room in duplicate. Colour to be specified by Engineer in charge. (Inspection by RDSO/RITES)

5000

303

1515000

... More
Supply of 16 Sq mm Multi-stand single core PVC Insulated copper cable as per IS:694 for connecting MEEB to SEEB and SPDs and SPDs to MEEB. Colour to be specified by Engineer in charge. (Inspection by RDSO/RITES)

2000

144

288000

... More
Supply of 10 Sq mm Multi strand single core PVC insulated copper cable as per IS:694 for connecting various equipments to SEEB.Colour to be specified by Engineer in charge. (Inspection by RDSO/RITES)

1000

87

87000

... More
Any other SOR items (Supply) from Chapter No.1-18

1

600000

600000

... More
Cutting of rock up to a depth of 300 mm and width of 300mm where rock is visible from surface, 4 concreting to ground level after laying cables with 1 cement: 2 sand : 4 graded stone aggregate 20mm nominal size and curing of concrete to the required number of days, except in bridges, culverts, level crossings, track crossings, cable pits, rocky soil including marking of cable alignment, clearing of debris etc., complete to the finished item of work as directed by site in-charge. Drg No.SK/CN/HQ/01/2022 All the material is to be arranged by contractor

1200

460

552000

... More
SOR No.1905-02 When rock is visible for more than 0.5 metre and up to 0.8 metre from the ground level, excavating the trench minimum 0.5 metre and maximum 0.8 mettre, laying of cable and concreting 200 mm x 200 mm over the rocky surface after levelling with soil/sand.

1000

200

200000

... More
Track crossing by horizontal boring method based on the S.C.RLY Drg No.5768A or drawing 6 no.DRM/J/6735 dated 7-8-03 (enclosed) and as advised by the engineer at site. This includes the supply and insertion(pushing) of GI pipe (80mm) confirming to IS.1239 heavy class in the bore drilled with the coupler between two pipes. All the joints of casing pipes should be tight and leak proof.

3000

1403

4209000

... More
Trenching under Rails for crossing the track(Track crossing) and refilling of trenches as per RDSO drawing No.SDO/CABLE LAYING /009. The track crossing shall be done at right angles.The depth of cable trench shall 7 be 1.2 Mtr. below the rail flange. The depth between top cable and the level of rail flange of the rail shall never be less than 1.0 Mtr.. The ballast shall be Stored separately while making the trench and the earth soil shall be stored separately. while re-filling the trench, the earth soil has to be filled first to the ground level and the ballast has to be properly put in the track. this work has to be done under supervision of supervisor of S&T and supervisor of P.Way

1500

141

211500

... More
Breaking of metal/ tar road and refilling after laying the cables as per drawing no.SDO/CABLE LAYING/010. The surface of the road shall be concreted to match with the old surface.

250

142

35500

... More
Laying different type cables in the trench/duct. Termination covered elsewhere.

1000000

5

5000000

... More
Excavation of square coil pit up to a depth of 1 Mtr. X 1.5 Mtr. For providing coil at location box, point, signals etc., This includes back filling and ramming of trench / pit after laying the cable and consolidation of soil.

500

181

90500

... More
SOR No.1916-02 Concreting of portion of the pipe at the bend near the culvert as per the drawing SK.15/11.(Per Unit= per bend)

50

1216

60800

... More
Providing of channel ramps for drawing cables at bridge/culvert entries duly providing GI bend/ flexible conduit 8 cm diameter and constructing channels from a depth of 0.8 meters to surface as per detailed technical specn. (Concreting to be done at the ratio of 1:4:8 - Cement, sand and fine metal for concreting will be supplied by contractor.

20

496

9920

... More
"Supply and fixing of MS-'C' channel of size 100mmx 50mm x 1200 mm with suitable clamps as per 13 drawing No. S&T/ RE/78/2/76 and fitting to GI pipe 65/50mm (to be supplied by Railways) of spec. IS-1239/ Part-1/ Light with couplings and with suitable clamps on Girder Bridges without drilling holes in the girders. GI Pipes are to be drilled with 6 holes of 1/4"" dia. per metres around the pipe in zig zag manner before laying the 6 metres pipe. "

100

495

49500

... More
Jungle cutting along with the cable route

30000

4

120000

... More
Cutting of masonry walls of at stations, cabins buildings and other locations as indicated by Railway engineer at site to a depth of 0.75 meters and supplying and fixing 50mm GI pipe The leading in arrangement shall be as per drawing no. RE/S&T/ ALD/SK/ 161/ 81.

5

610

3050

... More
Test lamp arrangement in LBs/RE cuttings.(Auto mobile handle type)(Per Unit= per location)

200

119

23800

... More
Supply and fixing of Teak Wood planks of of sizes as instructed by the site in-charge with smooth finishing 17 surface to be provided where ever required such as in location boxes relay room, equipment room and battery room, Fine wood polish of approved quality to be applied for two times after thorough application of emery paper. Fixing bolts and wood polish supplied by the contractor painting (Hardwood, paints, fixing bolts are to be arranged by contractor). Per

4

43600

174400

... More
Numbering location box as per standard practice and writing all termination particulars inside the location box as per details. This includes all main and tail cable particulars, writing of cable numbering of cables, polishing teak wood boards in two coats and painting hard wood shelves in two coats of black enamel.

500

280

140000

... More
Fixing relay bases, wiring in location boxes, bunching, fixing of relays as per circuit diagram. This includes fixing of condensers, resistance, 6 way / 1 way terminals/ WAGO, ND type fuses, LED indicators for fuses as per type fuses, LED indicators for fuses.

800

156

124800

... More
Fixing relay bases on the relay frames erected in Relay Room, Wiring of all types of relays by drawing various sizes of wires/multicore cable, fixing fuses, condensers, resistances, LEDs etc and wiring duly soldering the same as per approved circuit diagram, testing point to point before soldering and after soldering, bunching and lacing as per detailedtechnical specification. Different colour codes and sizes of wire to beused as per standard practice. This also 21 includes, provision of all PVC sleeves required to be provided. Copper lugs to suit to 16/02 wire and neat bunching, lacing with ModiNylon / Twine thread and using PVCdotted tape with buttons were required. This also includes soldering all the wires in the relay room with Rosine core of IS Spec. 1921 (60 percent and 40 percent Lead). Soldering should be done as per standard practice. This also includes inserting the clips, point topoint testing as per the circuit diagram and plugging relays to Relay bases (except Inter-cables, relays other materials such as Rosine core, flux, nylon thread. PVCdotted tape should be supplied by the contractor). Point to point testing should be done in the presence of Engineer-in-charge as instructed in two stages, one beforesoldering and the other after soldering.

1500

174

261000

... More
Earthing and soldering of cable armour.(Per Unit=Per cable)

4200

21

88200

... More
Manufacturing, supply, painting and fixing of markers of G / P / C / A / IB Markers / Number plates with engineering grade reflective sticker on MS sheet with clamps as per drawings / as per site incharge including all fixing materials.

200

308

61600

... More
Provision of SCREEN on signals when they fall within 2 meters from the live conductor by expanding 25 metal ( size.20mm x 60mm strand 3.25 mm wide and 1.6mm thick ) as per the instruction of site engineer incharge, This includes supply of all materials including earth electrode and earthing arrangements. Drg. No.RE/S&T/S. 16/T/SK/26.A.85 & Drg. No.RE/S&T/sig/Tender/Alt.A/SK/13/85.

20

3058

61160

... More
Strengthening of foundations of signals, Full/Half location boxes, by carrying out the earth work around the foundation, ramming of the earth, caring out masonry work from bottom of earth work using country stones and cement masonry to prevent the earth from slipping down the bank.

400

2813

1125200

... More
Fixing of point machines on PSC/Wooden sleepers as per standard drawing. Wiring as per circuitry includes fixing & wiring of point contactor unit frames and controlling relays . Includes fixing of crank handle ward plate.

10

4308

43080

... More
Fabrication and supply of GI termination box for point machine of size 45cm x 23cm x 12 cm, the termination box to be fabricated out of GI sheet 10SWG

10

2579

25790

... More
Wiring of Track circuits feed end, relay end complete with TLDs, batter-ies, chargers, track relays, double lead wires, providing insulation etc,. connected with track commissioning of track circuit including provision of bracket for TLD covers and painting. Anti-tilting arrangement has to be done for track relays, chargers & batteries.

20

1004

20080

... More
Fabrication, Supply and fixing of CALLING ON instruction boards, STOP boards with engineering grade 30 reflective sticker of size 600X900X1200 mm GI sheet, with MS angle of 75X75X6 mm with 6 me-ter length including paint, excavation of pit and concrete foundation etc..as per the instructions of sight in-charge. All necessary materials to be arranged by the contractor).

10

3549

35490

... More
Manufacturing and fixing of glass fronted box (key box) made out of teak wood of size 10 inches x 16 inches.

16

255

4080

... More
Fixing of PVC pipes & bends, drawing of required wires through the same up to functions like control 32 telephone, Dy.control telephone, magneto phones inside SM's office as per circuit diagram. This includes supply and fixing of required DPDT and rotary switches, PVC pipes and bends 25mm dia with 2mm wall thickness, Lightening dischargers and painting of particulars.

8

3628

29024

... More
Installation, testing and commissioning of Data Logger which includes the software configuration needed, 33 validation, taking test print, for networking for transferring the data to nominated location for monitoring and changing of EPROMS if any as per the instructions of the site in-charge, including alterations data base in Hq/SSE offices where ever required.

8

24280

194240

... More
Erection of Relay rack 1way / 2way / 4way with scaffolding suitably concreting tri-pod bases using J-bolts, 34 fixing rack supporting of size 50x50x6 mm on to the wall. Reel insulators are to be provided for insulating the rack from the scaffolding & tri-pod bases. ( payment based on number of equivalent 1 way relay racks).(Per Unit= Per one way rack)

24

341

8184

... More
Fabrication and supply of MS frames to suit 'Q' series relays to accommodate 6 No. in each set as per Drg.No. B.SG.CN. MISC.9.98 duly drilling required holes for relay bases (All materials such as frames, bolts, nuts and washers to be supplied by the contractor) (Only Relay bases will be supplied by the Railways).

335

294

98490

... More
Fixing relay bases on the relay frames erected in Relay Room, Wiring of all types of relays by drawing various sizes of wires/multicore cable, fixing fuses, condensers, resistances, LEDs etc and wiring duly soldering the same as per approved circuit diagram, testing point to point before soldering and after soldering, bunching and lacing as per detailed technical specification. Different colour codes and sizes of wire to be used as per standard practice. This 36 also includes, provision of all PVC sleeves required to be provided. Copper lugs to suit to 16/02 wire and neat bunching, lacing with Modi Nylon / Twine thread and using PVC dotted tape with buttons were required. This also includes soldering all the wires in the relay room with Rosine core of IS Spec. 1921 @40<37@ Tin and 40% Led). Soldering should be done as per standard practice. This also includes inserting the clips, point to point testing as per the circuit diagram and plugging relays to Relay bases (except Inter-cables, relays other materials such as Rosine core, flux, nylon thread. PVC dotted tape should be supplied by the contractor). Point to point testing should be done in the presence of Engineer-in-charge as instructed in two stages, one before soldering and the other after soldering.

2483

174

432042

... More
Preparation of Contact Analysis for 'Q' style relays as per detailed technical specification.

3245

14

45430

... More
Installation, testing and commissioning of RTU which includes the software configuration needed for networking for transferring the data to nominated location for monitoring as per the instructions of the site in-charge.

2

15744

31488

... More
Provision of one skilled and 2 unskilled staff round the clock to attend to teething trouble of the installation along with SI/CSI after the installation has been brought into commissioning. The work includes routine maintenance, failure restoration as per the direction of the SI/CSI.

15

43437

651555

... More
Non Interlocking arrangements

5

12300

61500

... More
SOR No.2701(02) Transportation of materials from any Stores to Site and vice-versa including loading and unloading. Lead above 50 Kms(Per Unit=PTPK)

400000

4

1920000

... More
SOR No.2901.1 (a) Stage -1 : testing of wires drawn point to point using buzzer. (Before and after soldering.)

300

316

94800

... More
Releasing of Warning Boards/stop boards

48

252

12096

... More
Releasing of block instrument.

16

307

4912

... More
Carrying out circuit alterations in the existing location boxes as per the new circuits which require excavation and releasing unwanted cables from the location box and taking new cables inside the location, clamping of new cables, filling the location box with standard up to the bottom of location and plastering.

175

612

107100

... More
Carrying out of alterations to the working circuits and fixing of relays and relay groups and energisation of 48 relays as per approved circuit diagrams. (All materials such as Rosin core, flux, nylon thread, eyelets and PVC dotted tape to be supplied by contractor. Indoor cables, relays and relay groups, fuses, LEDs, Resistances will be supplied by Railways.(Per Unit=per sheet of circuit diagram )

50

1447

72350

... More
Straight through / derivation with/without transformer joints: Installation Thermo shrinkable jointing kits for straight through / derivation joints for LC gate, pump houses etc where VF transformers are not required and derivatin 49 joint by using 2T trasformer ( to be housed in the joint) . This includes tapping of nominated Quad at a specific location shown by the Railway Engineer at site to the jelly field cable already laid. All material including valco tapes except thermo shrinkable jointing kit shall be supplied by the contractor. (Refer Annexure for instructions on cable jointing).(Per Unit=Joint)

32

979

31328

... More
Laying of HDPE duct 40/33 mm dia in the trenches and in protective works already provided.

200

4956

991200

... More
Installation /fixing and wiring of 15U rack, drawing of cable through aluminium ladder, neatly lacing the cables, fixing of earth bus bars, extending earth to various equipment through 16 sq.mm copper cable, fixing of power distribution panel with 5AC sockets. Aluminium ladder and lacing thread shall be supplied by the contractor.

15

562

8430

... More
Installation of 100/50/20 pair Krone terminal Box as supplied vide NS items on hard wood plank of size 8"x13"x1" plank and wiring. Hard wood plank and other materials like screws, bolts etc to be supplied by the contractor at his own cost.

32

114

3648

... More
Supply and installation of rack mounted 24F FMS fiber part no.fms-1u 24FS 24FP Raychem make including 24Nos 0.2db FC/PC adaptors and 24numbers 900 micron 1.5 meter FCPC pigtails. RDSO Spec No.: RDSO/ SPN/TC-037-2000 (Ver.3) or latest.

100

16285

1628500

... More
Blowing of armoured optic fiber cable (OFC Cable supplied by Railways) into the duct supplied vide NS.2 54 of supply portion by using blowing machine and associated works. Before blowing the duct integrity shall be tested. If any defect is found during duct integrity test, the entire length of HDPE duct from one chamber to another chamber is to be replaced by the contractor at free of cost.

200

7382

1476400

... More
Supply and Installation of OFC joint enclosure and splicing of Optic fiber cable (24 fibres) and testing as 55 per technical specification No. GR OJC-2/02 Sept 2003. Supply of Splice Enclosure (24 fiber) shall be of TVS make Part No.1500-L18X-XX as per Board specification of TEC and Schedule of supply enclosed. All materials including Fusion splicing machine used for fiber splicing and, OTDR for testing and other testing materials if any shall be arranged by the contractor

125

6416

802000

... More
Excavation of Jointing pit and provision of joint chamber of 1.2Meter dia. Of 60 cm height with 2-piece 56 cover on top and bottom cover with holes for drainage (reinforcement drawing will be as per technical specification).This includes water cooling of chamber, backfilling and ramming of the trench after cable laying and consolidation of soil as well as disposal of soil as per plan as advised by site engineer.

225

3745

842625

... More
Testing of fibres by splicing all 24 fibres

70

15818

1107260

... More
Fixing of 12 pair weather proof C.T. Box WAGO type and termination of 6 quad jelly filled cable on teak wood plank of size 375mm x 250 mm x 20 mm thickness

20

217

4340

... More
SOR Ch-19 to 37 Any other SOR items (labour) from Chapter No.19-37

1

600000

600000

... More
Supply of TD Multiplexer with thespecifications. a)Standard 19"" RackMountable device consisting of four E1interfaces, 2)dual optical ports with dual core and Single core path 20Kmsdriving distance. 3)Multidirectionsupporting 1 upto 5 direction either withoptical or E1. 4)Ethernet ports forcamera connectivity. 5)RS232 interfacefor RTU connectivity. 6)EM cards with8*E&M ports with 2W/4W setting.7)FXO/FXS card support with10*FXO/FXS ports. 8)Total 4 hotswappable slots for field upgradableMulti service Modular cards. 9)DeviceManagement with Telent & NMS. UnitSupport Audio Buzzer Alarm Interface.10)Potential Free contact. Dual DC with18-72VDC range. Accessories - AC- DCadaptor, E1 & E&M cable. Make : MROTEK or similar (Inspection :Consignee)"

30

208508

6255240

... More
Supply of Pre wired 36U rack (Cubicle) for Dual redundant arrangements of UFSBI electronics with 2 Siemens grey - Smoke grey powder coating (Rust proof and long life), tinted 3-4 mm thick tinted Acrylic Polycarbonate- Glass sheet fitted on front door and metal back door, with double lock and bottom cable entry facility. (Inspection : Consignee)

18

195750

3523500

... More
Supply of Electronics (Dual) for UFSBI interface as per IRS specification No. IRS S104/2012 Ver. 0 or latest (without relays) including two number modems (for use with two media - both dark OFC) and autochangeover card. (Inspection : RDSO)

45

792264

35651880

... More
Supply of independent non-vital mux with UFSBI or non-vital midules with FN-Mux for gathering I/O towards display of tracks, signals and LC Gates etc (Inspection : Consignee)

9

194700

1752300

... More
Supply of fan less embedded industrial grade computers (Similar to Moxa V2406 or better) with all accessories such as keyboard, mouse, antivirus, etc of industrial grade, including one number 43" VDU commercial grade with HDMI / DVI cable, inbuilt speakers as per approved specifications as recommended by RDSO (TAN No. STS/TAN/3007 Version 1.0 or latest) (Inspection : Consignee)

11

409839

4508239.78

... More
Supply of following items for stations:(Inspection by consignee)

-

-

710620

... More
"Manufacture and supply of Laminated boards of size 45 cm X 60 cm X 12mm thick for the following: 1. Battery care board - 1 No. 2. Guidelines for power supply arrangements - 1 No (Inspection : Consignee)" (Per Unit=Per Board )

16

2025

32400

... More
Supply of 19" - 42 U Rack complete with fittings for housing SDH equipment, FDMS, DDF and other equipment like cable managers, completely wired using krone module and other equipment like runaway ladders etc., as per technical specification below. It should be able to lock all the equipment with only order wire Telephone outside the rack. The rack should be of APW President / Rittal make etc., The components of the rack are specified below. It 8 includes transportation and installation of rack in prefab/building at specified stations. 1. Rack S33 42U 600'W x 600D - 1 No. 2. Fixed side panels 42U x 600 D - 2 Nos. 3. Front Glass door plain 42U/600W - 1 No. 4. Rear MS Door Plain 42U/600W - 1 No. 5. Castor with brakes-2 Nos. 6 Fans directly mounted on the top 48V DC 90 CFM-2 Nos. 7. Krone mounting bracket - 01 Nos. 8. MCB Mounting panel with MCBs - a. 32 Amps, MCBs(DP) - 2 Nos. & 6Amps MCBs(DP) - 6 Nos. 9. Earth continuity Kit - 01 No. 10. Equipment Trays - 5 Nos. 11. Channel with cable loops 42U - 2 Nos (Inspection : Consignee)

24

41600

998400

... More
Optical fiber tool kit (1) Tube cutter, (2) Duct cutter, (3) Hexa blade with frame, (4) Screw driver set, (5) Knife (6) Ties (7) Termination box, (8) Tool box (9) Tie bar, etc.. as required by site incharge. (Inspection : Consignee)

3

7842

23526

... More
Supply of Handheld OTDR of Model-930XC-20C or similar make with SC connector.Specifications as per 10 tender document. Product supply should comprise: a. Connector (FC or SC) connector for UPC & amp;APC) or(ST Connector for UPC) 1 No. b. OTDR Trace viewer software 1No. c.Installation disk , 1 No. d.Rechargable battery 1 No.e.Data transfer cable 1 No. f.AC adapter. g.Carrying Case.(Inspection by consignee)

1

370500

370500

... More
Supply of Optical Power Meter Model AE210. Warranty Eighteen months. Inspection by consignee.Make: Deviser & DBC Make: Deviser/Fuzikara/Stanlay/Flukeor similar(Inspection by consignee)

1

6990

6990

... More
Supply of Optical Source Meter,Model AE310A. Make: Deviser & DBC Accepted Make :Deviser/Fuzikara/Stanlay/Fluke or similar(inspection byconsignee)

1

14990

14990

... More
"Supply of Fiber splicer for splicing single mode fiber as per TEC spec GR/TX/OSM-001/04/Sept - 12 with latestamendments Product details: i)Splice Loss : 0.02db ii) Return Loss : 0.1 dB/100mm 1300mmiii) Electrode Life : 13 3000 to 5000 iv) Heat shrinkable sleeve:60mm/40mm v) Power inbuilt 12 V( nominal ) , 110V-230V AC / 50 Hz High precision CLEAVER and complete tool Kit required for splicing. USB Port ,Core Alignment with all accessories to be supplied with carrying case And spare electrodes Make : Fuzikura /Siemens / Ericcson / HP / Stanlay(Inspection- Consignee)

1

215000

215000

... More
Supply of rain proof protection coversmade with polyethylene sheet for 3/4aspect IRS type CLS unit. (Inspection :Consignee)

122

340

41480

... More
Supply of UTP cat 6E cable,unsheilded twisted 4 pair cable annexture ELA 568 V2/1 VL approved fire and flame resistance 250 MHz 24 AWG American AWG wiring case polythene TEC product. Make : Finolex/Legrand(Inspection : Consignee)

5000

31

155000

... More
Supply of LAN extender with all accessories as detailed below. 1.Line Type -2Wire (Single pair 16 operation), 2.Line impedence -135 Ohms, 3.Connector -RJ45, 4. Support speed of 144KBPS for distance coverage up to 8KM , 5.No.of Ethernet ports -4 (4 port switch ), 6.Power supply -230VAC and 48VDC . Make: NOMUS /MROTEK/D- link, etc... (Inspection : Consignee)

12

14050

168600

... More
Supply of Media converter Single mode Dual Fiber with Built in AC power supply unit supports 100Mbps with Driving distance of 15Kms with SC type connector and 10/1OOMbps Ethernet port (Inspection : Consignee)

13

7500

97500

... More
Supply, fixing and termination of RJ-45 jacks to CAT-6 cable.Make:D-Link (Inspection : Consignee)

130

15

2026.7

... More
"Supply of Digital insulation tester suitable for testing of cables in AC traction area. Range : 50V -1000V DC. Make: Rishabh / Meco/ Fluke (Inspection : Consignee) "

2

3380

6760

... More
Supply of Digital Earth Tester 0.01 to 99 ohms .in 5 ranges, 4 terminals type with all facilities .WACO make or similar. (Inspection by Consignee)

2

15088

30176

... More
Remote Service Terminal with Portable Terminal as per similar or latest Specifications HP All-in-One 12th Gen Intel Core i7 24-inch FHD Desktop (16GB RAM/512 SSD/Win 11/Wireless Keyboard and Mouse Combo/MSO/Intel Iris Graphics/IR Privacy Camera/Starry White (Inspection: Consignee)

12

70250

843000

... More
Supply of steel tubes galvanized ISI marked to IS: 1239(Part-I)/2004 in random 1 both end as per IS: 22 554:1999 socketed at one end and another end protected with plastic protector. Socket confirming to IS:1239/Part- 2/1992 with amdt.1 to 3 (Re-affirmed 2002) Ncm, bore dia 100mm, class medium GI PIPE-100MM. Make SAIL/JINDAL/TATA. The G.I. Pipe should have 4.5mm thickness, weight 12.5Kg per one meter at screwed & socketed End.(Inspection by RITES)

3600

1185

4266000

... More
Supply of Aluminium Ladders of height 5 feet for maintainer at Relay room and IPS room. (Inspectionby Consignee)

16

6799

108799.84

... More
Supply of SMPS based 110V/24-32 DC-DC converter rack containing 10 No. of DC/DC converter( Rating of DC-DC converters shall be defined by Engineer Incharge as per site requirement), modules, duly wired with ASM panel and rack for housing the DC/DC converter. (Inspection: RDSO)

6

83466

500796

... More
Supply of UFSBI Spares: (Inspection by RDSO)

-

-

6986070

... More
Supply of Automatic Media Changeover of modems working on redundant channels for data transmission on OFC / Quad for UFSBI (Inspection: RDSO)

44

30000

1320000

... More
Supply of data analyzer system for Telecom STM, PD Mux installation works with similar or latest 27 Specifications Dell Inspiron 5430 13th Gen Laptop, Intel i7-1360P/16GB/1TB SSD/14.0" (35.56CMs) FHD+ WVA AG with Comfortview Support 250 nits/Backlit KB+FPR/Win 11+MSO'21/15 Month McAfee/Platinum Silver/1.59KGs or latest, specification (Inspectionby Consignee)

2

74951

149902

... More
Transformer Rectifier 230V AC /24V DC /2A as per Spec No.lRS.S.91.2014 Ver.1.0 or latest.(Inspection by RDSO)

25

13381

334525

... More
"Supply of managed Expandable rack type STM-1/4 ADM L1.2 (for Long Haul application to work up to 29 60km) as per technical specn no. TEC/GR/TX/SDH 04/04 JAN 2011 with two direction STM 1 aggregate optical interface equipped for 21 E1's and 4 no. of 10/100 base T ethernet ports, order wire power supply units sub rack installation materials and accessories, manuals etc. the equipment should be fully wired for its ultimate capacity and provide redundancy for power supply and synchronisation. Model TJ1400 or similar.(Inspection by RDSO)"

4

283318

1133272

... More
Supply of Thermo shrinkable jointing kit for PIJF cable as per Spec. No. RDSO/SPN/TC/57/2015,Rev.1, 30 Amend 1, suitable for cable jointing kit for 20 pair cable . Firm's accepted offer Make/Nodel WESTERN CABLEX. (ITEM TO BE SUPPLIED- 20 Pair 0.63MM COND DIA PIJF CABLE AS PER RDSO LATEST SPECN).(Inspection by Consignee)

50

725

36250

... More
Supply of CLS Multi unit type 4 aspect complete with mounting socket to Drg. No. SA. 23002/A/M with latest amendment and IRS S 26/64. (Inspection: RITES)

126

14875

1874250

... More
Supply of Junction type/Directional type route indicator 3 way with mounting socket to drawing no.SA.23401 with IRS - S 66/84 with amendment-1 or latest. (Inspection by RITES)

10

17732

177320

... More
Supply of Junction type/Directional type route indicator 4 Way way with mounting socket to drawing no.SA.23404 with IRS - S 66/84 with amendment-1 or latest.(Inspection by RITES)

10

21164

211640

... More
Supply of Relay Fail Safe Time Element Electronic type with 120 seconds time delay plug in type. (Inspection by RDSO/RITES)

40

1536

61440

... More
Supply of Push Button Telephones with CLI and Speaker with RJ 11 Rosette of make-panasonic or Beetel or Superior. (Inspection by Consignee)

10

1018

10180

... More
Supply of Multi port Front End Processor with 02 Nos Dual port serial to E1 converter as per RDSO Spec No: IRS:S:99/2006 amd 3 or latest. (Inspection by RDSO)

1

165000

165000

... More
Supply of Central Monitoring Unit (CMU) as per RDSO Spec No: IRS:S:99/2006 amd 3 or latest. (Inspection by RDSO)

1

238000

238000

... More
Supply of RTU with 128 digital & 16 analog inputs as per RDSO Spec No.IRS-S-99/2006 or latest. (Inspection by RDSO)

5

231875

1159375

... More
Supply of High Density Polyethylene Pipes (HDPE) of 110 mm Outer Dia, 10 mm Wall Thickness, along with one coupler for every 6 Meters as per specification No. IS 4984: 2016 with latest amendments and Material Grade:PE 80. (Inspection by RITES)

4000

675

2700000

... More
Supply of 43 Inch Commercial Signage 4K VDU With 2 Years Extended Warranty. Make: LG, Samsung or Similar. (Inspection by Consignee)

10

66670

666700

... More
Supply of 55 Inch Commercial Signage 4K VDU With 2 Years Extended Warranty. Make: LG, Samsung or Similar.

5

75520

377600

... More
Supply of Track feed battery charger to work on 110V AC for charging 1 or 2 or 3 or 4 lead acid cell of 80AH (10 Amps) used in track circuit as per RDSO Specn. No. IRS.S.89/2013 Ver. 1.0 latest.(Inspection by RDSO)

20

5775

115500

... More
Supply of SOT 18 card for model Tejas TJ1400 required for STM 1 optical branching with 2 no.s of S11 SFP module (Inspection RDSO)

4

81066

324264

... More
Supply of 8 Port E&M card which can be configurable 2W/4W which supports to MAPLE 4C (V4) with accessories and cables . Make: MROTEK/MAPLE. (Inspection by Consignee)

8

34500

276000

... More
Supply of 8 Port E&M card which can be configurable 2W/4W which supports to MAPLE 4C(O) (V4) with accessories and cables . Make: MROTEK/MAPLE. (Inspection by Consignee)

8

41800

334400

... More
Supply of 10 Channel FXO/FXS card supports to MAPLE 4C (V4) with accessories and cables . Make: MROTEK/MAPLE. (Inspection by Consignee)

4

39500

158000

... More
Supply of 10 Channel FXO/FXS card supports to MAPLE 4C (O)(V4) with accessories and cables . Make: MROTEK/MAPLE (Inspection by Consignee)

4

42300

169200

... More
MAPLE 4C (O) FXS/FXO Combo Card suits MAPLE 4C (O)(V4) with accessories and cables . Make: MROTEK/MAPLE. (Inspection by Consignee)

8

41200

329600

... More
VDU Panel of 42'' or 43'' to display ABS Section.(Inspection by Consignee)

10

37296

372960

... More
Supply of 2 MB Ethernet card for PD mux as per RDSO specification IRS-TC 68/2012. (Inspection by Consignee)

4

34073

136292

... More
Supply of Tag block 200 way to RDSO Spec. No.IRS.S.77/2006 (Rev.1) of Drg. No.SA.24751 (Inspection by Consignee)

10

1000

10000

... More
Wire wound resistors, 2.2 ohms/ 50 Watts (Inspection by Consignee)

100

84

8400

... More
"Supply of testing of split core structure, non contact measurement, Real In Time testing, high accuracy, high stability, resistance range 0.01-100, resolution 0.001, accuracy +/- 2% rdg +/- 3dgt, working Temp. & humidity -20 55, 20% RH 90% RH, Detector Light and Sound Alarm, IP-54 protection, RS485 communication, with extended 4 digit LCD. Display can be mounted up to 2 Mtr. distances from detector unit. (Suitable for Transmission Line/Railway facilities/Communication/Sub Station/ Electrical equipment Grounding. Consists of (Model no-KOBLE 2800 KB ver.3.0 or similar): (a) Main detector unit- 01no., (b) LCD enclosure fitted with Aviation plugs-01 no. (c) Set of detector to LCD enclosure connecting two cables each 2mtr. Length fitted with Aviation connector-01 set (d) Rs- 485 connector with 0.5 mtr. Cable -01 no (e) RMCU with PFC-01 no. Make : SELF (KOBLE) ( Warranty Period : Upto 30 months from the date of supply)" (Inspection by Consignee)

10

86637

866375.1

... More
Supply of GIS mapping LT 800H TABLET WITH CHARGER AND ANTENNA as per technical specification. (Inspection by Consignee)

4

422150

1688600

... More
"Supply of Nylon -66 Point insulations complete set With RDSO spec No-IRS-S-40/84 or latest consists of 1.Gauge tie plate insulation one set (Insulating plate drg No. T-10372=01No, insulating bush drg No. T-10368=03 Nos, insulating washer drg No. T-10371=06 Nos) 2. D bracket insulation one set (Insulating plate (RH) drg No. S-3265=01 56 No, insulating plate (LH) drg No. S-3266=01 No, insulating washer drg No. S-8640=04Nos, Insulating bush drawing No.S- 23199=04Nos) 3.Stretcher bar insulation one set (Insulating plate drg No.T-10367=01No, insulating bush drg No.T-10368=02Nos, insulating washer drg No.T-10371=04Nos) 4. L-bracket insulation one set (Insulating plate drg No.S-8804=01No, insulating washer drg No. S -8640=02Nos, insulating bush drawing No.S-8813=02Nos) Inspection by RITES. Make: TITANIA ( Warranty Period : Upto 30 months from the date of supply)"

1000

459

459020

... More
Supply of RTU with 64 digital & 16 analog inputs as per RDSO Spec No.IRS-S-99/2006 or latest. (Inspection by RDSO)

4

150000

600000

... More
Excavation of cable trench in all kind of soil except hard rocky areas including clearing of roots of 1 trees,rocks, bushes etc., to a depth of 0.5 mtr-0.6 mtr to accommodate the duct under NS item and to a width of 0.5 mtr. This shall include refilling of earth as per instructions of Engineer Incharge. Laying of cables is not included in this schedule. In case of less depth, payment will be done proportionate to depth subjected to minimum depth of 500 mm.

42000

150

6300000

... More
Supply and placing of trunking and capping of RCC duct in a trench ofwidth 300mm and depth of 600mm as per technical specification. Inspection of RCC duct shall be carried out by RITES. Route Kilo Meter

42000

1785

74999820

... More
Excavation of pit, casting concrete foundation and erection of apparatus case Full size as per S.C.RLY Drg No.5781 and fixing of 1 No.of 'E' type lock for the front door,fixing of teak wood reapers & planks of various sizes as 5 per requirement and painting the apparatus case inside and outside with one coat of redoxide and two coats of aluminium paints (foundation bolts and nuts,' E' type lock, cement, river sand, stone jelly of size 20/20mm, Teak wood reapers,paints, varnish, fixing bolts and nuts and all other miscellaneous material required for the work shall be supplied by the contractor)

500

9875

4937500

... More
Supply, painting and fixing of cable Gland plate for full GKP box as per S.C.RLY Drg No.5774

500

533

266500

... More
Excavation of pit, casting concrete foundation as per Drg. No. RDSO/M/00011/R4 using metallic 7 templates, for erection of Colour light Signals upto 4 aspects (foundation bolts, cement, river sand, stone. jelly of size 20/20mm dia and all other miscellaneous materials required for the work shall be supplied by the contractor).Rate Analysis

40

14042

561680

... More
Erection of Ground type shunt signal complete including surface base, signal pole, LED aspects/Lenses, bulbs with holders (whichever is applicable), fixing of lens guards, number plate, termination of tail cables, wiring of 8 signal unit, provision of EWS locks and painting of one coat of redoxide and two coats of Aluminium /.enamel paint, (Supply of Ground type shunt signal complete including surface base, signal pole, LED aspects, holder, bulbs and lenses is not covered in this schedule). [Wire PVC 3/0.75mm copper, lens guards, EWS locks, enamelled number plates, bolts and nuts, lead wool, paints and all other miscellaneous materials shall be supplied by the contractor).

5

2097

10485

... More
Excavation of earth and providing earth pipe of size 50mm dia, 3.5mm thick 2.0m. long G.I. pipe with masonry tub constructed around at earth locations as specified by site Engineer. Alternate layers of 30kgs-char coal and 9 30kgs-common salt to be filled in the pit while closing. The pipe perforation etc., to be carried out as per drawingNo.S.C.Rly.Drg.No.5775. The earth pipe to be connected to the function with cable as supplied by Railways. Earth reading should be less than 03 Ohms The reading should be painted on the masonry tub. The masonry tub of300X300X300mm should be covered with cement slab. ( All materials to besupplied by the contractor except cable.)

600

5100

3060000

... More
Supply, Installation, Testing and Commsissioning of Ring Earth/Perimeter eatrh using Copper Plate Earthing System complete with provision of (i) Copper plate 300mm X 300mm X 3 mm, (ii) Earth Pit 6 ft depth filled up with charcoal 10 kg & salt 25 kg in alternate layers up to 4 2 ft from bottom,(iii) (iV) Water funnel on Perforated Gl pipe of length 4.5 ft., (iv) Cast Iron top plate 12" x 12" (v) Drawing of copper-earth from earth to location with 25 mm x 3 mm 10 copper strip for termination (all miscellenous materials to be supplied by the contractor(Drg.No.S.C.Rly.Drg.No.5773) (vi) It includes Supply and installation of 6 number of copper plate earthings and including supply and interconnecting 50mm x 6mm GI tape for making ring earth for 4 number of earths , and connecting Class A earths(two number ) to the ring earth.(vii)This item also includes supply and installation of Copper Tape for BRC on walls with suitable insulated stand side relay room/Equipment room as per site requirement. (Only 35 sq mm/16sqmm cables will be supplied by railways - covered undewr different item of SCH A) . All interconnections upto final function / final point of earthing is incuded in this item.(Per Unit =Per Goomtie/Location)

6

192000

1152000

... More
"Provision MS flat connection from Earth pit to Signals including a) Supply and laying of MS Flat of size 11 40X6mm at site b) Supply of GI bolt of size M12X40mm with two Nuts along with two plain washers and one spring washer c) Drilling of holes in MS flat of different sizes at site d) Cutting with bending and twisting of MS flat at site e) Painting of MS Flat with one coating of red oxide as primary and two coats of anti-corrosive black paint and f) Drilling of holes in Location Boxes at site."

2500

293

734375

... More
Breaking of RCC concrete in Relay Room / Panel Room for drawing cables to ground floor/ 1st floor as per site requirement.

7

3700

25900

... More
Providing services of helping hand man power (Watch and ward) rate as per Ministry of Labour & 13 Employment Dt:03/04/2023 under 'B' area to carry out miscellaneous/sundry works in the office/field between 08.00 hrs and 20.00 hrs of the day and accompanying Railway staff with all expenses of transportation, accomodation, food, consumables etc., with all ascents/descents, taxes, octroi, cess, fees, duties, with contractors tools.

1100

816

897600

... More
Shifting of existing working functions like signals/Shunt/Calling on/Points/Track circuits etc.,from old cable to new laid cables carefully without affecting the traffic under disconnection/blocks.(Per Unit=Per Cable )

150

1460

219000

... More
Supply and fixing of cross on the signals (signal not in use) made of hard wood of size 1000mm X 100mm X 20mm (painted white as per Signal Engineering Manual) and suitable clamp made of MS flat.

122

328

40016

... More
Supply and installation of SC to SC or PC-SC or FC-SC 3 meter long patch cords as directed by site incharge.

1500

680

1020000

... More
Smart RFID Marker SM1500 Telephone HSN Code 90314900 Part No. SML1014. (Inspection by Consignee) Make : Komplex or STANLEY or similar.

1500

2265

3398400

... More
Design and preparation of computer aided (Auto CAD) diagrams. Note: Details Design and drawing of above drawings and submission of two draft copies for approval. One copy is returned either duly approved for making a 18 fiar copy or for resubmission for approval after incorporating the changes as required by railways. After preliminary approval required number of prints are submitted for Administarative approval. After the Administarative approval negatives of the above drawings , a soft copy on a CD along with required number of final prints are submitted. After completion of work 6 sets of asmade documents are to be submitted in bound booklets.

-

-

308000

... More
Supply and filling of River sand / Sieved quarry dust / Robo Sand in the RCC Cable duct

1200

1100

1320000

... More
"Modifications to existing EI to suit ABS working at SKZR-MMZ SECTION as per approved ELECTRONIC INTERLOCKING PLAN (EIP) as per clause 3.15 of Technical Specifications. 1)Supply of Kyosan Make EI Equipment as 20 per RDSO Specification RDSO/SPN/192/2019 With Latest Amendment Required for Alteration of Existing EI as per item No.8 below. 2)Inter connecting cables, connectors, terminals, mounting arrangements,fixures & accessories to make EI system alteration functional. 3)Alteration of Existing Application Logic Programme to suit Modified SIP. 4)Alteration to existing interface circuit diagram to suit Modified SIP. 5)Factory Acceptance Test of EI System. 6)Site Acceptance Test of EI System. 7)Installation, Testing & Commissioning of EI System as per Modified SIP. 8)Supply of I/O card, PIO3C(PIO2- LOG) -01 No (Inspection RDSO). 9)RELAY RACK -01 No (Inspection Consignee)."

1

3660000

3660000

... More
Supply of EI documents ("As made") as per technical specification. Approval shall be submitted on A3 Paper/Tracing sheets as per SCR practice. 6 sets of all documents in proper binding from the approved drawings shall 21 be taken and submitted to Railways along with application on logic and software tools related to EI as per TC.No.9/2022 Dt.18.10.2022, Soft copy, Autodad copy, Scan copy of ASMADE documents & TSAA copys, 06 sets of all documents soft copy to be uploaded in 32 GB Pen drive (Not less then Speed 150MB ). Including 03 sets supply of necessary documents for obtaining TSA approval of EI should be submitted.

3

125000

375000

... More
Augumentation, Installation, wiring, testing of DCDP. Minor items to be done like casing/capping where required to be supplied by contractor.(Per Unit =Per Station )

5

14033

70165

... More
Supply and installation of active lightning arrestor of class-A for building protection of ERICO 3000Make or 23 similar along with Down conductor of ERICORE or similar, Upper & Lower termination kit of Ericore or similar, Lightning event counters and any other miscellaneous material required for installation with prior approvalof engineer incharge which shall work on controlled streaming principle along with counter as per technical specification enclosed & S.C.RLY Drg No.5777. Installation to be done by OEM authorized firm/Vendors. (Inspection by RITES)

4

315000

1260000

... More
Track crossing/ Road Crossing by horizontal boring method at culverts/track/pucca road based on RDSO report no BS-105.This also includes insertion of HDPE pipe of 110 mm/G.I Pipe of 100 mm in the bore drilled (Supply of HDPE pipe & GI pipe is not included)

2450

2264

5546800

... More
b.Fixing and wiring of direction type route indicator - 2/3 way :Fixing of offset bracket using 'U' bolts and 26 nuts erection of posts type shunt signal termination of tail cables, provision of EWS lock and painting of one coat of red- oxide and two coats of aliminium/enameled paint. The work also includes drilling suitable holes on the CLS post and provision of a through bolt with nut to prevent the offset bracket from slipping down.

16

1824

29184

... More
Fixing of Offset brackets using 'U' bolts and nuts, erecting of Calling On Signals/'A' marker lights, termination of tail cables and wiring, provision of EWS lock, number plates/ markers boards and painting. The work also 27 includes drilling suitable holes on the CLS post and provision of a through bolt with nut to prevent the Off-set bracket from slipping down. (Supply of Calling On Signal / 'A' marker light, LED aspect / holders and bulbs and off set brackets is not covered in this schedule). ['U' bolts and nuts, through bolts with nut, EWS lock, Enamelled number plates, wire mesh, PVC/Nylon sleeves, paints and all other miscellaneous materials shall be supplied by the contractor.

52

1427

74217

... More
Transporting and supply and installation of Concrete (RCC) route indicators at intervals of 50 meters as 28 per technical specification. They should be of standard RCC with letters of one side SCR & other side Legend should be as directed by officer incharge as per drawing no. SK 12/10 of RVNL/SC In case of telecom quad cable joint locations it shall be painted with GREEN and ORANGE colour for normal indication of cable path. (Inspection by RITES) Per

1500

807

1210500

... More
Fabrication, Transportationand fixing of aluminium ladder at site made of Aluminium angle of 31 size38mmx5mm width 280mm,Flat size with powdercoated colour as desired byengineer incharge at siteand fixing of 25mmx5mm,Drilling of suitable holes forfixing of Hylam sheet 3mmthickness on ladder and 2Nos of PVC trough 100 mmwith cover fixed on hylamsheet along the ladder withall fixtures necessaryancillary materials requiredfor fixing to be supplied andas directed by engineerincharge at site

720

2865

2062800

... More
Laying of RCC / DWC pipes carrying from the stock of central place at station to the work spot without32 causing any damage and placing them in the trench duly clearning the ballast per track crossing / down the culvert in the trencyh, gap between DWC / RCC pipe and collar has to be closed using cement mortar. (DWC / RCC pipes will be supplied by Railways) and all other materials viz., collars for the joints, cement mortar for closing gaps between collar and pipes are to be supplied by the contractor.

500

50

25000

... More
Localisation and restoration of fault on main cable as per technical specification. (Per Unit=Per location)

20

7733

154660

... More
Laying of GI Pipes of 50/100/150 mm. dia. with coupling wherever required as per Railway requirement over the Cement bridges, girder bridges, drainage, culverts etc. In case of cement concrete bridges/Culverts, GI pipes are to be provided with brick masonry of 300 x 300 x 300 mm at an interval of 2M and the remaining portion to be 34 covered with earth. In case of Girder bridges, suitable M.S. Clamps are to be provided at every 1 M with all fixtures and supports and the pipe ends are to be closed with brick masonry abutments of size 0.5M x 0.5M x 0.5M . The cables are to be taken through the pipes without causing any damage. The pipes are to be drilled with holes 60 Nos. of 1/4" dia for 6M length around the pipe before laying in zig zag manner as per detailed technical specification. ( Only GI pipe will be supplied by the Railways. Remaining all the materials required for the work are to be arranged by the contractor ).

2300

91

209300

... More
"Supply ,transportation andinstallation of Cable ladder rack with all fixtures ,Triangle Bases,Insulators duly fixed on rack with powder coated and color ofcable ladder to be matched with the relay rack supplied by Medha Servo Drives and as directed by engineer incharge at site."

22

8600

189200

... More
"Supply ,transportation and installation of Cable termination rack similar to Medha Servo Drivesor similar with all fixtures ,Supporting Angles,Triangle Bases,Insulators,Din Rails duly fixed on rack with powder coated and color of rack to be matched with the relay rack supplied by Medha Servo Drives and as directed by engineer incharge at site." IBH/LC Gate/Auto

60

27280

1636800

... More
Release of complete indoor and outdoor equipment from locations and transportation of released material to the nominated store depot. The electronic equipmentcords must be packed with perforated bubble cushion wrap and segregation into cartons with all card details mentioned on boxes duly stickering and plastic paper wrapping.

4

90292

361168

... More
Laying of HDPE pipe 110mm dia 10mm thickness along with collars in trenches at places of platform cutting etc.. And where required as per the instructions of site encharge.

1500

55

82500

... More
Wiring & Fixing of Auto Visual display unit(Auto VDU) to Station Master( along with 2Nos. of 32/42 inch Monitors) As instructed by Incharge Supervisor Suitable arrangements shall be made to fix the terminal in the Station/Goomty as per the instructions of Engineer in charge. Railway will provide single Phase 230V AC /110V DC only.

5

20000

100000

... More
Videography of the work/route :Video recording should also be taken in the presence of the Railway 41 representative, in such a way that off and on should cover the Railway track, chainage, kilometer post or any milstone with railway representative,. Also recording measurement after actual site verification as per the existing practice to continue. Section wise final soft copy to be submitted in DVD/Pen drive.

60

310

18630

... More
Installation & commissioning of MAPLE 4CS (V4)

24

12000

288000

... More
Fabrication, supply and installation of Monitoring panel domino type (Drg.No.B/GSU/MISC/09/2022) 43 complete with LED etc., and prewired so as to display the signals & Track Sections controlled by the Goomty &two signals at both ends as instructedby Incharge Supervisor Circuit wiringincludes wiring of relay base plate toother base plate, to IDF, to tag block, wiring of circuits as per approved wiring diagram, jumpering and soldering after testing, power equipment, operating panel, key lock, test boards fuse boardsetc, (Per Unit=Per Station/ Goomty)

8

57676

461410.88

... More
Installation & Commissioning of UFSBI systems

45

75000

3375000

... More
Excavation of pit, casting concrete foundation as per S.C.RLY Drg No.5772 using metallictemplates, for erection of Colour light Signals upto 4 aspects (foundation bolts, cement, river sand, stone jelly of size 20/20mm dia and allother miscellaneous materials required for the work shall be supplied by the contractor).

110

5008

550880

... More
Erection of surface base, signal pole, mounting of Colour Light Signal upto 4 aspects complete on signal pole / offset bracket, (for LED /filament bulbs) with lenses, triple lamp holder, filament switching units, CLS transformers, current regulators (whichever is applicable), fixing of ladder with platform complete and concreting of ladder shoe, fixing 46 of number plates, marker board, lenses guard, fixing of speed Limit board, whichever is necessary, termination tail cables, wiring of signal unit,provision of EWS locks, and painting of one coat of redoxide and two coats of aluminium/enamel paints. When the aspect is fixed on offset bracket using 'U' bolts and nuts, a through bolt shall be provided by drilling of hole in the signal pole to prevent the offset bracket from sliding down. Note:- (Supply of surface base, offset bracket, CLS pole, CLS aspect complete, ladderwith shoes and platform, Speed limit board, LED aspects, current regulators, lamp holders, lamps,filament switching unit and CLS transformer is not covered in this schedule). ['all nuts,through bolts and nuts, cement, stone jelly 20/25mm dia, river sand, Signal Colour Rings, all fixing bolts and nuts, lead wood, paints PVC/Nylon sleeves, enamelled number plates, enamelled marker boards, EWS locks, and all other miscellaneous materials for the work shall be supplied by the contractor).

126

5501

693126

... More
Supply & Installation of Ultra Sonic highvariable frequency Rat Repellant Make

48

2625

126000

... More
Labour assistance for SE/JE in day to day works i.e., checking the curves/strainght alignment of formation 48 levels etc., carying the tools and equipment etc., watch and ward during the courseof execution of work as per the instructions of concerned SE/JE (as per chief labour commissioner letter no:1/8(6)/2019-LS II (dt.27.3.1029)(Per Unit=per day )

840

710

596400

... More
Supply and installation of UPS 1000va, along with batteries for 30 min backup, Numeric , as per instructions of engineer in charge.

10

9534

95340

... More
Supply & fixing of Aluminium Boards each of size 1000X600 mm (Axle counter Warning, STOP, 50 ENTERING AUTOMATIC BLOCK TERRITORY, ENTERING ABSOLUTE BLOCK TERRITORY, etc) made of 3mm thick Alluminium sheet etc. as per Drg No. B/GSU/MISC/02/22 including MS angle of size 75X75X6 mm Thickness, 2m long with paint & Bottom plate of 300X300X5 mm. (Inspection by Consignee)

42

6250

262500

... More
Database modification at central place/Test room/control office to suit to station ABS modification.

5

5000

25000

... More
Wiring from relay to intermediate tag block and intermediate tag block to data logger tag block along with 16/0.2 wire(Per Unit =Per Input )

533

350

186550

... More
Supply and fixing of rubber mating thickness 2mm. As per IS- 15652/2006 with suitable adhesive material

150

2390

358500

... More
"Supply. installation. testing and commissioning of Fixed 2 mega pixel bulet - network camera with housing Specification : 1/2.8 Progressive Scan CMOS,Digital WDR, 3D DNR, 10 meters IR range, 12V DC±10%, ICR Make: Matrix/Bosch/Axis"

40

7665

306611.2

... More
"Supply. installation. testing and commissioning of 8CH NVR networkvideo recorder. Make: Matrix/Bosch/Axis "

5

20657

103285

... More
Supply, installation, testing, commissioning of 2 TB surveillance hard disc suitable for 8 Channel NVR to store the video footage up to 15 days. Make: Seagate / Western

5

7269

36345

... More
Supply and installation of 21.5 inch Monitor with all connecting cables to monitor CCTV cameras at location.

5

10653

53265

... More
"Supply, installation, testing and commissioning of 12 port 10/100 ethernet switch. Make: DIGISOL,HIKVISION or DLInK "

5

8444

42220

... More
Overall commissioning of cameras and arrange network to head quarters

5

32480

162400

... More
"Suuply of spare Cameras 2 mega pixel bulet - network camera with housing Specification : 1/2.8 Progressive Scan CMOS,Digital WDR, 3D DNR, 10 meters IR range, 12V DC±10%, ICR Make: Matrix/Bosch/Axis". (Inspection by Consignee)

12

6132

73584

... More
"Supply of Display Unit for EI MTC similar to LG 55'' (139.7cm) 4K Smart UHD TV of Model No.55UP7500PTZ or latest. (Extended warranty , Total 3 years)"

4

49000

196000

... More
Installation, testing and commissioning of electrically operated lifting barrier, complete with Casting of cement concrete foundation for pedestal and boom rest post, cabling, power supply connection & wiring with complete outdoor work as per approved drawing, wiring etc.(Per Unit=Per LC)

2

46739

93478.98

... More
Supply and fixing of retro reflective (High Intensive Prismatic : HIP)stop board made out of luminium sheet 2 mm thick and lettering in three languages and fixing arrangements to boom pipe and as directed by engineer in harge at site

4

3235

12940

... More
Excavation of pit and concreting foundations for resting stand/meeting stand and erection of booms, resting stand and meeting post (approx. 10 Nos) (all the require bolts and nuts are arranged by the contractor)

2

16800

33600

... More
Supply of paint approved quality and painting of sliding type boom, boom movement frame, resting stand meeting post etc. as per regular standard practice with 2 coats of enamel paint black & yellow colour with 12 mm width retro reflective RED Yellow sticker

2

5600

11200

... More
Fixing of sliding type mechanical type boom, make assembly movement drive mechanism, resting stand 67 meeting posts and fixing of E type locking plate to meeting post and in gate lodge as per site in charge instructions. Note: All required nut & bolts, chains, padlocks 2 Nos and other miscellaneous are supplied by contractor. Note: All required nuts & bolts, chains, padlocks 2 Nos and other miscellaneous are supplied by the contractor.(Per Unit=Per LC Gate (both booms) )

2

26275

52550

... More
Provision of Security guards round the clock beat from up home signal to down home signal to avoid theft of signalling amenities in 12 hour shift(per unit=12 hrs)

1020

434

442680

... More
Shifting of S&T location/battery boxes (Horizontal Relocation) by excavating the earth around the location boxes without damaging the cables to the required depth and slewing the boxes along with the foundation block by JCB / 69 Hydra to get required clearence without interfering the movements of trains and also without disturbing the train operation system and closing the pit after getting the required clearence from center line of the track with all contractors material,labour,tools and plant with all lead and lift etc.., and as directed by the engineer incharge.(Per Unit=Each full/half/quater box)

50

5309

265477.5

... More
Breaking of existing Full/Half/Main location boxes/Main Signal/Shunt Signal/Compensator/ Crank /D.Wheel/Winch/G,F.Lever/Pedestal old Foundation and removal of debris and levelling with the available earth at site.

160

3339

534240

... More
Full location Box: Supply and fixing of GI flat of size 1050x25x3mm as given in drawing no. 71 RVNL/S&T/SC/06/2016. to connect all cable armous to earth point with suitable nuts/ bolts as given below A)GI nuts/boltsof size 8x25mm with two flat and one spring washer of 23 set B) GI nuts/boltsof size 12x40mm with two flat and one spring washer of 02 set as per site incharge.(Per Unit=Per LB)

400

888

355416

... More
Provision of skilled labour as per instructions of Site Incharge.

600

625

375000

... More
Provision of un-skilled labour as per instructions of Site Incharge.

1200

443

531600

... More
Supply of fixing of Fire Extinguisher CO2 type (Minimum Capacity 5 Kg)

10

8840

88400

... More
Scanning of As made approved documents after signature and handing is over to Sse in charge in a CD. List of documents to be scanned a)SIP b) ESP c) TOC d) VDU layout e) interface ckt and detailling book f) logic circuits g) Track bonding diagram etc.,

5000

8

40000

... More
Installation, Commissioning and Testing of split core structure.( Warranty Period : Upto 30 months from the date of supply)

10

14600

146000

... More
Construction of cable coil pit back side of relay room , Goomty and IB hut etc., as per site requirement, it 78 includes digging of pit, construction of side walls with bricks, coilling and bunching of cables, filling the pit with sand and minimum 10cm layer of concreting on top with 1 cement : 3 sand :6 graded stone aggregate of 20mm normal size. All Material and labour for the work to be arranged by the contractor . Item to paid as for size of pit in cubic metres .

50

3867

193393

... More
Supply and providing of Polymeric Positive Temperature Co-Efficient Device self reseting type (PPTC) suitable for Railway Applications.(Inspection by Consignee)

2500

60

150000

... More
Supply of 1 loop Addressable fire alarm panel which consists of display board which will have 160 character display board with touch keypad, Mother board which will have CORTEX 32 Processor , Inbuilt RS-485 Networking circuit for peer to peer networking , Inbuilt USB 2.0 Port for upload and download the configuration tools, two 80 inbuilt programmable inputs , two inbuilt NAC's and Three programmable relays and 4 loop card circuits , power supply board which will have SMPS fully protected board , which its operates on 120 to 220V AC +/- 10% with 50/60 Hz , battery backup 24V DC with built-in charger, the panel have IP-50 rating optional : for BMS integration MODBUS converter , Graphical Software , Software for TCP/IP module , provision for Auto dialer approval UL listed. As oer RDSO Specification No.RDSO/SPN/217/2018 ver 2.0 or latest. (Inspection : RDSO)

2

150000

300000

... More
Supply of Addressable Multi detector combination of heat cum smoke wth isolator base binary coded address setting. Dual LED's for 360 degress visibility. Sleek low-profile housing design. Regular 100mm base IP rating: IP-42. Approval : UL listed , (As per RDSO Specification No.RDSO/SPN/217/2018 ver 2.0 or latest) Inspection : RDSO)

20

5400

108000

... More
"PVC Insulated, Armoured, Unscreened, Underground Railway signalling cable copper conductor, size 12 core x 1.5 sq.mm conforming to RDSO Specification No. IRS:S-63/2014 Rev.4.0 in drum length of 1 Km (Inspection : RDSO) "

900

238533

214680114

... More
Underground Railway Jelly filled, 6 Quad cable for telecommunication with Specification No. IRS: TC 30- 2005 Ver. 1 with Amendment No. 5 of size dia 0.9 mm. In the packing length of 1 km drum. (Inspection : RDSO)

240

333004

79921022.4

... More
"24 Fiber Armoured Optical Fiber Cable as per RDSO spec.no.IRS.TC55/2006 (Rev.1.0)with Amendment 1.1, 2.0 & 3.0 or latest in drums of packing length in 3km] (Inspection : RDSO)"

240

69403

16656720

... More
PVC insulated, Armoured, Unscreened, Under Ground Railway Signalling Cable copper conductor, Size: 24 core x 1.5sq.mm confirming to RDSO Specification No. IRS:S.63/2014 Rev.4.0 500 mtrs length in each drum. (Inspection : RDSO)

48

424972

20398669.44

... More
Supply of Colour Light Signal LED Signal Main LED Signal Lighting unit 110V AC LED signal RED Aspect, Main LED signal lighting unit, 110VAC, retrofittable in existing CLS housing and compatible with AC LED ECR as per Specification No. RDSO/SPN/199/2010/Rev.1.1.(Inspection : RDSO)

122

9060

1105320

... More
Supply of Colour Light Signal LED Signal Main LED Signal Lighting unit 110V AC LED signal Yellow Aspect, Main LED signal lighting unit, 110VAC, retrofittable in existing CLS housing and compatible with AC LED ECR as per Specification No. RDSO/SPN/199/2010/Rev.1.1(Inspection : RDSO)

244

9076

2214680.64

... More
Supply of Colour Light Signal LED Signal Main LED Signal Lighting unit 110V AC LED signal GREEN Aspect Main LED signal lighting unit, 110VAC, retrofittable in existing CLS housing and compatible with AC LED ECR as per Specification No. RDSO/SPN/199/2010/Rev.1.1 (Inspection : RDSO)

122

10266

1252452

... More
"Supply of LED lamp Signal ROUTE aspect LED signal lighting unit, 110V AC, retrofitable in existing CLS housing and compatible with AC LED ECR as per specification No. RDSO/SPN/153/2023, Revision 5.0 or latest. (Inspection : RDSO) "

280

5444

1524465.6

... More
"Supply, Installation and commissioning of IPS with 300AH VRLA batteries with latest RDSO spec.conforming to RDSO/SPN/165/2012,( IPS scheme is enclosed) (Inspection : RDSO)"

4

992501

3970004

... More
Supply of 2KVA CVT for IPS as required at Site(inspection:Consignee)

6

49000

294000

... More
Supply of LED lamp Shunt aspect with current regulator and health monitoring alarm unit with selection for use with conventional ECR or LED ECR to RDSO Spn. No. RDSO/Spn/199/2011 (draft) (RDSO/Spn/199/2011 (draft) or Latest.(inspection by RDSO)

75

5959

446925

... More
"Supply of 20 pair 0.5mm dia polythene sheathed jelly filled underground telephone cable with poly aluminium moisture barrier annealed copper conductor double steel tape armoured with polythene jacketed as per RDSO Specn. No.IRS.TC.41/97 , Amdt.3 or latest length should be 500 Mtrs. drum."(inspection by RDSO)

10

135700

1357000

... More
"Supply of 50 pair X 0.5 mm Dia Polythene Insulated Polythene Sheathed Jelly filled Underground 14 Telephone cable with poly aluminum moisture barrier annealed copper conductor double steel tape armored with polythene jacketed as per RDSO Spec. No. IRS: TC/41/97 with Amdt.3. Packing length should be 500 Mtrs per drum. Make/Brand: Self"(inspection by RDSO)

10

300310

3003100

... More
Supply of LED Signal lighting unit A/AG Marker. (Inspection : Consignee)

140

6160

862400

... More
Supply of DC-DC converter of various ratings as required as per site. (inspection by RDSO)

40

15400

616000

... More
Supply of 300AH VRLA Battery bank with 5nos of spare batteries. (inspection by RDSO)

5

391000

1955000

... More
MSDAC design and installation for Automatic Signalling

-

-

8410000

... More
Design, Supply, transportation and installation of Pre stressed Precast RCC structure for ABS hut ( 16 m X 5.5 m) including foundation as per Typical Drawing No.S.C.Rly. Drg no.C5757 and as per Technical Specification 1 3.8.duly adopting appropriate foundation & Super structure design at a particular location by carrying out Soil testing from NABL approved laboratories and designs being proof checked by M/s RITES. All the materials used shall be as per the approved list issued by Dy.CE/Works/SC vide Lr No. No.SCR-HQ0ENGG(SOR)/1/2020-Dy.CE/WORKS/SCR; Date.13.09.2023. It includes provision of Proper approach from track formation to ABS hut. The width of the approach shall not be less than One meter.

-

-

23706804

... More
Fencing for ABS hut as per RDSO DRG No. ETI/C/0186 et al or latest shall be provided around the hut leaving a minimum 1000mm gap from the building. Earthwork with protection shall be done to level the earth around the building inside the fencing.

-

-

1440463.1

... More
Third Party Inspection of ABS hut @ 10.5%

5

412928

2064640.1

... More
Approach Road for ABS hut

4500

1120

5040000

... More
Supply 35 Sq. mm 2 core LT XLPE copper conductor cable as per IS 7098 part-1 Inspection by RITES

10000

1085

10856000

... More
Laying, testing and connecting of following sizes XLPE LT UG cable as per specification enclosed. 2Core 70/150 Sqmm/4 Core 25/50/95/120 sq.mm 4core.

10000

12

120000

... More
Supply and laying of 8 SWG GI wire with 40GSM Zink coated, conforming to IS:280-2006 or latest, it is to be laid with UG cable for earth continuity.

5600

12

67200

... More
Supply of Integrated 4'-20W LED (Indoor) tube light fitting surface mounted including power LEDs complete with all accessories and confirming to CEE/SC's latest Specification attached in tender.

60

370

22200

... More
Fixing and connecting on 02 Nos of TW/PVC round blocks with nails/ screws(fixing in indoor building) .

60

40

2400

... More
Supply fixing, testing and connection of 30W LED type weather proof street light fitting including power LED's complete with all accessories and confirming to CEE/SC's Specification as attached in tender

-

-

13112

... More
Supply of Ceiling fan of Energy efficiency BEE 5star rating, Fan motor of inverter driven controlled by microprocessors (BLDC), as per latest CEE specification.

16

2230

35680

... More
Fixing and connecting of BLDC 1200mm sweep star rated ceiling fan with all accessories i.e. Canopy, down rod etc, as per specification enclosed.

16

45

720

... More
Supply, fixing and connecting of Hum free 0-4-Steps Modular Electronic fan regulator with all accessories of Havells/Atomberg/Bajaj/Crompton make.

8

346

2768

... More
a) Supply and wiring of concealed / Surface point wiring (without PVC conduit/PVC Casing caping) by 02 10 Nos., of 1.5sq.mm PVC insulated, multistrand copper conductor with 1.5sq.mm one no.of PVC insulated multistrand copper conductor for earth continuity as per specification enclosed. The price shall also includes 6A, module switch. The wire shall of FRLS type of Havells/Finolex/Finecab/Legrand make.

84

204

17136

... More
b) Supply and fixing of ISI marked PVC conduit pipe/PVC casing & caping with Elbows & Jn.boxes etc. for point wiring.

84

73

6132

... More
Supply and laying of 32 mm dia 2 mm thick PVC pipe (ISI mark) concealed in roof slab and wall with all required accessories including masonry work and labour charges etc. Makes: GoldMedal/GM/Sudhakar/Polyline/ Polycab.

400

37

14800

... More
Supply, fixing and connecting of modular switch &socket as of GM make or equavalant Legrand/Havells make including all accessories complete.

-

-

6472

... More
Supply and fixing of Ivory coloured Polycarbonate Modular plate with Polycarbonate surface box / Metal surface box / Metal flush box (for concealed) with all accessories complete, of GM make or equavalant Legrand/Havells make including all accessories complete.

-

-

14408

... More
Supply, fixing, connecting, installation, testing and commissioning of Automatic change over panel 16 complete for colour light signalling system having 3 phase supply 60 Amps capacity with all connected accessories viz. Rotary selector switch, air break contractor, MCCBs, MCBs LEDs alarm buzzer, alarm reset micro switch etc. meeting RDSO technical specification No. I/SPEC/PSI/CLS/0020 with latest amendment. Make: As per RDSO approved vendor NOTE: 1. All MCB/MCCBs fitted with Microprocessor/ electronic release based relays and B curve. 2. Ics 100% Icu

4

33875

135500

... More
Supply and run of 2 nos, 6.0 sqmm, 1100 V PVC (FRLS) insulated flexible copper conductor wires and one run of 2.5 sqmm PVC (FRLS) insulated flexible copper cable for earthing in existing PVC conduit/Casing and capping pipe.

160

63

10080

... More
"AC Single Phase Static Energy meter of Accuracy Class 1.0, 240V, 50Hz, with Backlit LCD Display of rating 10-60A & with 1 push button. (Measures & displays kWh, kVAh, V,I,PF, frequency, kW, kVA, six months history of Energy & MD in kW & kVA) with Transparent Hinge type Box."

4

2025

8100

... More
Supply and fixing of 8 way (8+24 module) single/three phase outgoing TPN Vertical Distribution box. 19 similar to model no. DHDMTVOSRW08 of Havells make with all connected accessories or Equavalant makes of legrand/L&T/C&S /Siemens/Schnider/ABB/Hensel to incorporate the MCB's incorporated in the tender/Work order schedule.

4

11736

46944

... More
Supply and erection of C curve FP MCBs of 63 A with all connected accessories. Makes: legrand/L&T/C&S /Siemens/Schnider/ABB/Havells

8

2412

19296

... More
Supply and erection of C Curve/Series SPN MCB of 10/16/20/32 A as advised by the engineer incharge with all connected accessories Makes: legrand/L&T/C&S /Siemens/Schnider/ABB/Havells

16

753

12048

... More
Supply and erection of ISI marked HDPE pipe of PE-100 grade PN 6 class of 1 1/2 inch(50 mm) nominal dia with all necessary accessories to fix with any structure.

400

90

36000

... More
Supply and fixing of 3" dia. "B" class GI pipe Confirming to IS 1239 Part -1 (2004) for cable supporting including couplers, clamps, bolts and nuts etc., complete.

40

806

32240

... More
Supply and erection of Earth pit as Per specifciation RDSO Drg No.ETI/OHE/P/7021 Rev.A or latest. including Electrode, earthing enhancement materials etc. The earth pit shall comprise of following materials and shall be done as explained. (i) Excavation of earth for one pit in any soil and refilling(as per the Drg No. RDSO Drg No.ETI/OHE/P/7021 Rev.A or latest). (ii)Supply and erection of "B" Class GI pipe dia 50mm, 3.1 mtrs length including GI socket and nutsAs per RDSO Drg No.ETI/OHE/P/7021 Rev.A or latest.(iii) Drilling of 26 Nos of 12mm dia holes on GI 24 pipe dia 50mm. (iv) Supply and erection of Charcoal - 45 Kgs for each earth pit (v)Supply and erection of Salt -35 Kgs for each earth pit. (vi) Supply and erection of pre fabricated RCC of size 0.55m X 0.55M(550mm) with wall thickness of 0.125m(125mm) with height 0.3m (300mm) along with RCC(1:4:8) cover with .04m thickness(40mm) and funnel with iron mesh. As per RDSO Drg No.ETI/OHE/P/7021 Rev.A. (vii)Supply, laying and connecting of 8 SWG GI wire with 40GSM Zink coated, conforming to IS:280-2006 or latest, it is to be laid & connected from equipmet to earth electrode for continuity-per site condition. (viii) Transportation charges including loading & unloading of earthing system material to site/location. and complete erection including all connectections with all necessary accessories complete.

8

3350

26800

... More
Excavation of cable trench in all types of soils (inclusive of under the track) except hard rock duly filling river sand in excavated trench before and after laying cable and laying of bricks in excavated trench .

2400

112

268800

... More
Excavation of cable trench /earth pit complete duly digging/breaking hard concrete / Platforms/bitumen top / under the track / road etc.including refilling as per the specification enclosed.

400

376

150400

... More
Providing and laying in position cement concrete of specified grade 1:3:6 (1 cement : 3 manufactured sand derived from Recycled concrete Aggregate (RCA) : 6 graded stone aggregate 20 mm nominal size Recycled Aggregate (RA) ) for all necessary plinths/foundations etc duly digging the requried soil/concrete at desired area with requred dimensions as advised by Site incharge..

8

5815

46520

... More
Preparation of designs and drawings for OHE.(Per Unit=Location)

8

567

4536

... More
Concrete for foundations and plinth in other than hard soil and rock. (Incl.foundation for AT/BT masts)

40

5348

213920

... More
Erection of traction masts and main masts of switching stations & LT supply transformer station.(Per Unit=MT)

3.2

1599

5118.4

... More
Erection of fabricated steel work such other than masts (SPS etc.)(Per Unit=MT)

2

8095

16191

... More
Supply without insulator and erection of 25 KV solid core suspension insulator.

4

1641

6566

... More
Supply without insulator and erection of 25 KV post insulator.

16

749

11984

... More
Supply and Erection of all types of copper jumpers.

16

3006

48104

... More
Erection of structure bonds.

40

220

8820

... More
Drilling of holes on Rails

80

70

5600

... More
Supply and erection of Earth electrode at TSS/AT mast

16

4543

72688

... More
Supply and Erection of Earth Bus

80

168

13440

... More
Supply and erection of copper strips for equipment earthing

40

675

27020

... More
Oil filtration, erection testing and commissioning of 25KV/240 volts, 5/10/25/50 KVA LT supply transformer

8

4245

33964

... More
Supply, erection of 25KV dropout fuse switch (without insulator)

8

8508

68068

... More
Supply and erection of Anti-climbing device etc. for LT supply transformer.

8

1431

11452

... More
Dismantling of a pedestal/ pin insulator

16

343

5488

... More
Dismantling of copper jumper

16

101

1624

... More
Releasing of plinth/pole mounted LT supply transformer

8

2065

16520

... More
Erection of traction structures consisting of rolled and fabricated under Power Block.(Per Unit=MT)

3.2

1599

5118.4

... More
Erection of fabricated steel work other than masts under Power Block.(Per Unit=MT)

2

8095

16191

... More
Erection of 25 KV post insulator under power block.

16

189

3024

... More
Erection of all types of copper jumpers under power block.

16

203

3248

... More
Dismantling of a pedestal/ pin insulator under power block.

16

343

5488

... More
Dismantling of copper jumper under power block.

16

101

1624

... More
Extra on erection rates for steel work done manually under item No. 3 (a).(Per Unit=MT)

3.2

798

2553.6

... More
Extra on erection rate for steel work done manually under item No. 3 (b).(Per Unit=MT)

2

4046

8092

... More
Supply and erection of number plates

8

402

3220

... More
Supply and erection of caution boards

8

630

5040

... More
Supply of Traction masts and main masts of switching stations , LT supply transformer station as per RDSO drawings and IS Specifications. (Per Unit=MT)

3.2

100602

321927.2

... More
Supply of Fabricated steel work other than masts (such as SPS)(Per Unit=MT)

2

104539

209079.5

... More
Supply of 7 mm dia solid round Hard drawn dropper wire as per RDSO specification.

40

593

23720

... More
Supply of 50 sq.mm Annealed Stranded Copper jumper wire as per specification.

64

593

37952

... More
Supply of 25KV Post insulator for 11(b)

16

4252

68036.8

... More
Supply of 25 KV post insulators for item 28

8

8504

68036.8

... More
Supply of 25 KVA, 25 KV / 240 V Single phase, Oil filled Auxiliary Transformer with all fittings as per RDSO Specification No. ETI/PSI/15 (08/2003) or Latest. (Inclusive of 18% GST) (P.O No. L8215907100940 dated 22- 12-2021)

8

123900

991200

... More
Supply of Link pull Rod for 25 KV D.O. Fuse switch as per RDSO specification.

8

3588

28704

... More
Supply of M.S Flat of size 50x6 mm

800

148

118656

... More
Supply of M.S. Flat of size 40x6 mm.(Per Unit=MT)

4

72050

288200



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.