National Security Guard Tender

For getting the details of etenders, if you are looking for information about them from the cumbersome government websites but are tired of doing so, Bidassist comes up with a one stop solution. It collates every Eproc telangana tender on Bidassist. One can approach it for the bidding process, registration process, etc., are explained below.

National Security Guard - NSG Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date8 Nov 2024
Closing Date18 Nov 2024
Tender Amount₹ 15,74,513 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
b) Wall Fan upto 400 mm

5

500

2500

... More
c) Exhaust fan upto 380 mm

50

537

26850

... More
d) 450 mm exhaust fan.

10

701

7010

... More
Replace of bearing suitable for following size ceiling fan/wall fan /Exhaust Fan TATA/SKF/NBC( Rate are less of U/S material i.e Dismantal material will not be taken back by NSG)

-

-

-

... More
a) 1200/1400 mm Sweep ceiling fan

200

178

35600

... More
b) Wall Fan upto 400 mm

10

178

1780

... More
c) Exhaust fan upto 380 mm

100

178

17800

... More
d) 450 mm exhaust fan.

20

213

4260

... More
Providing & fixing (Replacement) of suitable size of bush in following size ceiling fan/wall fan /exhaust fan etc. as required.C( Rate are less of U/S material i.e Dismantal material will not be taken back by NSG)

-

-

-

... More
a) 1200/1400 mm Sweep ceiling fan

20

70

1400

... More
b) Wall Fan upto 400 mm

3

70

210

... More
c) Exhaust fan upto 380 mm

10

70

700

... More
d) 450 mm exhaust fan.

5

79

395

... More
Providing and replacing the 2.5 MFD/3.15 MFD fan capacitor in the ceiling fan/exhaust fan/wall fan, including connection and testing, etc., as required. (The old capacitor will be retained by the contractor).

100

52

5200

... More
Providing and replacing the 4 MFD fan capacitor in the ceiling fan/exhaust fan/wall fan, including connection and testing, etc., as required. (The old capacitor will be retained by the contractor).

30

59

1770

... More
Reconditioning of the oversized bush bearing housing to a suitable ball bearing in the ceiling fan/ exhaust fan/ Wallmounted fans as required and assembling and testing of the fan after repair. All the scrap material should be retained by the contractor.

20

170

3400

... More
Providing and replacing the worn-out M.S. shaft of the exhaust fan /wall fan with a suitable size new shaft etc., as required, including removing the old shaft, installing the new shaft, and testing the fan. All the scrap material should be retained by the contractor.

20

160

3200

... More
Providing and fixing PVC clamp with connector for the ceiling fan capacitor in the existing ceiling fan, including connection,testing, etc., as required, including credit for the old PVC clamp, which will be retained by the contractor

20

15

300

... More
Providing , installation , testing and commissioning of 100 watt 450 mm sweep 1440 RPM , noise level upro 64 DB wall mounting metal body air circulator Fan Single phase 230 Volt ,single phase, model WM Vorter Air circulator 18" CG make or equivalent make BAJAJ/ALMONARD

2

12488

24976

... More
SH: Repairing/ maintenance of U G Cable

-

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.

-

-

-

... More
Upto 35 sq mm

500

200

100000

... More
Above 35 sq mm and Upto 95 sq. mm

400

217

86800

... More
Supplying and making straight through joint with cast resin compound including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.

-

-

-

... More
3½ X 50 sq. mm

4

3542

14168

... More
3½ X 95 sq. mm

6

4231

25386

... More
Add GST Multiplying Factor @ 0.0633 ( for GST 18 % instead of 12%) On item 1& 2 ( B part) DSR ITEMS ONLY

1

14328

14328.2

... More
SH: Preventive maintenance/ Testing of 11 KV HT, VCB, Transformer & L.T. ACB

-

-

-

... More
Oil filteration in 630 KVA transformer to improve Di-electric strength with high vaccm filter machine i/c testing of BDV

1

15000

15000

... More
Oil filteration in 400 KVA transformer to improve Di-electric strength with high vaccm filter machine i/c testing of BDV

2

12000

24000

... More
Topup with new transformer oil in the existing transformers for mainting required level for 04 nos Transformers

100

180

18000

... More
Replacement of silica jal

8

250

2000

... More
Conducting measurement of earth pit resistance

25

250

6250

... More
Transportation charges for equipment

1

6000

6000

... More
Servicing of and complete overhauling of ACB

3

6000

18000

... More
Servicing of and complete overhauling & testing of VCB 800A & 630 Amp

6

12000

72000

... More
Maintenance kit for ACBs

9

1660

14940

... More
GST @ 18% on item 3.1 to 3.9

1

31714

31714.2

... More
SH: Repairing/ maintenance of Motor pump and Lifts

-

-

-

... More
Repairing/Rewinding of following rating Monoblock motor pump set of 03 Phase with suitable superior quality of super enameled copper winding wire with C class insulating material including dismantling of burnout winding i/c repair/ replacement of bearing, seal, bushes, rotor steel bush, reassembling and testing complete as required i/c taking the motor from site to workshop and reassembling at the site (removed copper and other material will not taken by the department)

-

-

-

... More
a) 01 HP

2

4345

8690

... More
b) 02 HP

2

5812

11624

... More
c) 03 HP

2

8262

16524

... More
d) 05 HP

2

12159

24318

... More
d) 7.5 HP

2

12302

24604

... More
e) 10 HP

3

15976

47928

... More
f) 15 HP

3

18437

55311

... More
Repairing/Rewinding of following rating submersible motor pump set of 03 Phase with suitable size of super quality poly insulated of same gauge copper wire i/c repair/ replacement of insulating paper, seal, copper thrust bearing , bushes, rotor steel bush, reassembling and testing complete i/c taking the motor from site to workshop and reassembling at the site as required (removed copper and other material will not taken by the department)

-

-

-

... More
a) 05 HP

1

11176

11176

... More
b) 7.5 HP

1

13202

13202

... More
c) 10 HP

2

14525

29050

... More
d) 15 HP

2

16699

33398

... More
SITC of 10 HP open well Submersible pump 65X65 mm inlet and outlet dia operating at 3 phase 415 volt 50 HZ of modal KOS-1050+ of KSB make with the following specification Head Range : 30- 47 metres Power Ratings : 7.5 kW/ 10HP Voltage Range : 300 to 440 Volts (Three Phase) Insulation : F Class Protection : IP 55 Impeller : Cast Iron Delivery Casing : Cast Iron Motor Body : Cast Iron Pump Shaft : Carbon Steel Sealing : Gland Packed ( Note: Old Submersible pump will kept by Contractor) or equivalent make/model KSB/CG/Texmo/ Kirloskar brothers ltd.

1

56292

56292

... More
Providing and fixing of 12" cabin fan for lift including dismantling of existing and connection with suitable copper wire, testing and commsiiong etc as required ( (Dismantal material will not be taken back by NSG) make Rica or equivalent make approved by Engg in charge

8

6036

48288

... More
Providing, installation, testing and commissioning of 07 Watt round base COB type LED light Recessed mounted deep recessed adjustable/fix downlight for good-quality illumination to be installed in lifts make Bajaj model BRDCSL 7W LED WH or equivalent Havells & C&S & Philips

11

1451

15961

... More
Providing, installation, testing and commissioning of 10 Watt PDC Housing LED Bulkhead Luminaire with Opal di user, equipped with 2 kV in-built surge protection with IP65 protection rating. to be installed in lifts saft area make Bajaj model BIBWP 10W LED or equivalent Havells & C&S & Philips

43

1402

60286

... More
Supply and fixing of 12 V DC 2.5 AH ARD Battery in existing panel for Lifts as required Make- Exide Model-XPLORE 2.5 AH or equivalent Make Amaron ( Rates Less of US battery)

5

1587

7935

... More
Supply and fixing of 12 V DC 18 AH ARD Battery in existing panel for Lifts as required Make- Exide Model-Power safe plus 18AH or equivalent Make Amaron ( Rates Less of US battery)

4

2784

11136

... More
Providing and fixing of 12 V DC 150 AH Excide XP1500 Battery in Make- Exide Model-Excide XP1500 for fixing in DG set or equivalent Make Amaron ( Rates Less of US battery)

2

14222

28444

... More
Misc Works :-

-

-

-

... More
Providing and fixing of 24 Watt LED base Aviaition light input voltage 150-300 V, having heavy duty , hard clear glass cover with IP 65 weather proof , Heavy duty construction , painted with weather & heat proof yellow epoxy powder coating, covered with transparent borosilicate hard glass, sealed with rubber gasket & rataining matel ring, ultra bright glow LED in red color i/c connection with suitable wire , Testing and commissioning etc as required . make KALIN or equivalent make approved by Engineer-in-charge

3

16511

49533

... More
Providing and replacement of Daikin split air conditioner drain pump Mini aqua condensate pump for ADM block and officers mess AC

8

6651

53208

... More
Dismantling existing unservicable Rotary Compressor of air conditioner ,1.5 TR capacity and replacing it by new one of same capacity with guarantee for one year. ( Rates are less of U/S compressure i.e Dismantal compressure will not be taken back by NSG)

2

13042

26084

... More
Providing Replacement of unservicable PCB for air conditioner unit as required. (Dismantal material will not be taken back by NSG)

1

6474

6474

... More
Providing repair of faulty PCB for A/C unit as required. (Circuit repair)

6

1200

7200

... More
Providing new fan motor for condensor for air conditioner unit as required. ( Less of U/s outdoor fan motorl cost).

1

4604

4604

... More
Providing new fan motor for Room unit for air conditioner unit as required. (Dismantal material will not be taken back by NSG)

1

1500

1500

... More
Providing new fan blade outdoor unit for A/C unit as required. (Dismantal material will not be taken back by NSG)

3

1240

3720

... More
Providing replacement of blowerof indoor unit for air conditioner unit as required. (Dismantal material will not be taken back by NSG)

1

1611

1611

... More
Providing replacement of remote of indoor unit for air conditioner unit as required.

3

1500

4500

... More
Providing and replacement of Copper condenser coil for 1.5/ 2.0 Ton split type air conditioner as required. ( Less of u/s condenser coil cost).

3

3500

10500

... More
Providing and replacement of waste pipe length of 02 MTR for 1.5/2.0 ton Split type Air Conditioners as required.

25

215

5375

... More
Providing & fixing of Insulation Material for copper pipe length of 02 MTR in 1.5/2.0 ton Split type Air Conditioners as required.

20

731

14620

... More
Re-filling of Gas (charging of Refrigent R - 22/410) for 1.5/2.0 ton Split Air Conditioners as required

20

3295

65900

... More
Supplying and erection of 9 Mtrs long continously tapered octagonal pole (bolt fixing type) in single section with single longitudinal weld & galvanized with 1.5MTR each side long Double arm standard bracket made upto 40NB dia HDG pipe suitable to mount on pole having top dia 70MM i/c required nut/bolt and following specification to be installed on the existing foundation :- Make CG/Bajaj/philips/valmount

-

-

-

... More
a) Top dia - 70mm

-

-

-

... More
b) Bottom dia - 155 mm

-

-

-

... More
c) Thickness of sheet - 3mm

-

-

-

... More
d) Base plate size - 250mm X 250 mm X 16mm

-

-

-

... More
e) Integral junction box duly hot dipped galvanised complete with door and locking arrangement as required.

-

-

-

... More
f) The pole should be suitable for fixing of bracket for installation of 02 nos Security light fittings.

3

19193

57581.85

... More
Supplying, installation, testing and commissioning of 110 Watt LED street light luminaire made up of die-cast alu- minium housing, with IP66 degree of protection, complete with the driver, LEDs with optical lens, toughened glass cover, etc. The luminaire should have suitable for opera- tion on voltage range 140-270V, 1Φ, 50Hz AC supply sys- tem, and a mechanical impact resistance rating of lk=07. surge protection of ≥ 10KV, PF≥ 0.90 and minimum sys- tem luminous efficacy of 120 lm/W 5700 K . The minaire shall be designed for an average system life L70B50: 50000 hours and suitable for mounting on the pole bracket up to outer dia 40 mm, including installation on existing street light pole bracket connections and earthing etc., as required. LM 79 and LM 80 reports need to be submitted from a NABL/UL accredited lab to verify the above parameters. Cat no ZELA P 132L WH PO TG SD (Bajaj) or its equivalent philips/Havells/c&S/CG make

6

13119

78714

... More
Wiring of 09 MTR Security light pole with 2X(3X1.5 sqmm size) of PVC insulated & FRLS multi core round flexible cables ,1100 V PVC insulated & sheathed with bare annealed copper conductor as per IS:694-2010 copper conductor from looping box to light fitting including interconnection with connector,testing complete etc as required Havells/Standard/HPL

3

4136

12408

... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required a)Double pole

6

656

3936

... More
Supplying and fixing of 4Pole,3 phase 63 Amp connector bolt type with bakelite sheet MCB rail in the existing junction box of the pole etc as required

3

317

951

... More
Add @ 1% labour cess for item 1.1 to 5.19

1

15589

15589.24



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.