National Institute Of Technology Tender
... More
For getting the details of etenders, if you are looking for information about them from the cumbersome government websites but are tired of doing so, Bidassist comes up with a one stop solution. It collates every Eproc telangana tender on Bidassist. One can approach it for the bidding process, registration process, etc., are explained below.
National Institute Of Technology - NIT Tender
Civil And Construction
Eprocure
Opening Date8 Dec 2023
Closing Date29 Dec 2023
Tender Amount₹ 20,12,000
Costs
EMD
₹ 40,300Document Cost
₹ 1,180Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_NITW_784592_1Bid Award Id
ViewTender No
49/NITW/EMU/CIVIL/2023-24Tender Authority
National Institute Of Technology ViewPurchaser Address
-Website
http://eprocure.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Making the opening in brick masonry including dismantling in flooror walls by cutting masonry and making good the damages to walls,flooring and jambs complete, to match existing surface i/c disposalof mulba/ rubbish to the nearest municipal dumping ground, allcomplete as per direction of Engineer-in-Charge
-
-
-
... More
For door/ window/ clerestory window
-
-
-
... More
Substation near STP - 1 (replacing one window with door)
3
3793
-
... More
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
1
263
-
... More
SH2: Steel works
-
-
-
... More
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3 mm M.S. gusset plates at the junctions and corners,
all necessary fittings complete, including applying a priming coat of
approved steel primer
-
-
-
... More
Using M.S. angels 40x40x6 mm for diagonal braces
-
-
-
... More
New door @ Substation near STP
5
29021
-
... More
Providing & fixing glass panes with putty and glazing clips in steel doors,
windows, clerestory windows, all complete with :
-
-
-
... More
4.0 mm thick glass panes
20
21293
-
... More
Providing and fixing bright finished brass 100 mm mortice latch and lock
with 6 levers and a pair of lever handles of approved quality with necessary
screws etc. complete.
5
4273
-
... More
SH3: Plinth Protection
-
-
-
... More
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement
: 3 coarse sand (zone-III) derived from natural sources : 6 graded stone
aggregate 20 mm nominal size derived from natural sources) over 75mm
thick bed of dry brick ballast 40 mm nominal size, well rammed and
consolidated and grouted with fine sand, including necessary excavation,
levelling & dressing & finishing the top smooth.
330
247269
-
... More
SH4: Patchworks and painting
-
-
-
... More
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in propershape,raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge
-
-
-
... More
With cement mortar 1:4 (1 cement : 4 fine sand)
220
120428
-
... More
Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete
1850
36537
-
... More
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
1850
288692
-
... More
Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content.
-
-
-
... More
With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre
1850
136807
-
... More
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.
-
-
-
... More
One or more coats on old work
1150
162150
-
... More
Supplying and applying of Nitocote wall guard (fosrac brand) for External walls where the dampness is observed and instructed by Dept. including all materials, labour incidental and operational charges complete etc., for 2 coats on old external walls after applying one priming coat of Nitoprime AW (fosrac brand). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes and filling of cracks with Nitoseal PU50 as per the direction of Engineer-in-Charge.
-
-
-
... More
Procedure to be followed: 1) Surface Preparation: Surface shall be prepared by mechanical grinding to remove all loose mortar, laitance, oil, grease, decayed matter and algae growth.
2) Filling of Cracks: Identify cracks on the walls and then chasing them open in the form of “V” groove (Cutting of the crack shall be done of size 10 mm x 10 mm) and Fill the “V “groove with NITOSEAL PU50 properly.
3) Priming coat: The prepared surface shall be applied one coat of acrylic primer, Nitoprime AW prior to the application of Nitocote wallgaurd, prime coat should be air cured for 6 hours. 4) Wall gaurd application: Nitocote wall gaurd (Fosroc brand) at a thickness of 110 microns DFT each coat, in two coats. Each coat must be air cured for 6 hours. (GST applied as per DSR-21) Note: The above work has to be done with the help of trained and skilled labour.
960
240000
-
... More
Filling of Cracks: Identify cracks on the walls and roofs, then chasing them open in the form of “V” groove (Cutting of the crack shall be done of size 10 mm x 10 mm cutting) and Fill the “V “groove with NITOSEAL PU50, a single component low modulus gun grade elastomeric sealant based on polyurethane technology. The applied sealant shall have movement accommodation factor (MAF) of 50% and Shore A Hardness of 32. The applied material shall have average peel strength of 220N and peak peel strength of 260N. (GST applied as per DSR-21) Note: The above work has to be done with the help of trained and skilled labour.
250
37500
-
... More
Finishing walls with Acrylic Smooth exterior paint of required shade :
-
-
-
... More
Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface
690
83317
-
... More
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :
-
-
-
... More
One or more coats on old work
420
43176
-
... More
Supplying and applying of roofguard (fosrac brand), a single component acrylic polymer modified, elestomeric fiber reinforced waterproofing coating applied in three coats of thickness 1 mm DFT in three coats after applying one priming coat of Nitoproof WB primer (fosrac brand) on the roof, including all materials, labour incidental and operational charges complete etc., . The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes and filling of cracks with Nitoseal PU50 as per the direction of Engineer-in-Charge.,
-
-
-
... More
Procedure to be followed: 1) Surface Preparation: Surface shall be prepared by mechanical grinding to remove all loose mortar, laitance, oil, grease, decayed matter and algae growth.
2) Filling of Cracks: Identify cracks on the walls and then chasing them open in the form of “V” groove (Cutting of the crack shall be done of size 10 mm x 10 mm) and Fill the “V “groove with NITOSEAL PU50 properly.
3) Priming coat: The prepared surface shall be applied one coat of acrylic primer, Nitoproof WB primer prior to the application of Roofgaurd, prime coat should be air cured for 6 hours. 4) Roof gaurd application: Roofgaurd (Fosroc brand) at a thickness of 1 mm DFT in three coats. Each coat must be air cured for 6 hours. (GST applied as per DSR-21) Note: The above work has to be done with the help of trained and skilled labour.
760
481840
-
... More
Lettering with black Japan paint of approved brand and manufacture
160
984
-
... More
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin-incharge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
100
73865
-