Mission Bhagiratha Department Tender

For getting the details of etenders, if you are looking for information about them from the cumbersome government websites but are tired of doing so, Bidassist comes up with a one stop solution. It collates every Eproc telangana tender on Bidassist. One can approach it for the bidding process, registration process, etc., are explained below.

Mission Bhagiratha Department Tender

Works
Civil And Construction
Water Storage And Supply
Opening Date3 Jul 2024
Closing Date12 Jul 2024
Tender Amount₹ 1,19,51,374 
Notes
Download

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Routine maintenance of transformer in operation covering insulation resistance oil, break down strength. Reconditioning / replacement of silicazel, cleaning of transformer and topping upto oil level if required (extra cost will be paid for oil).

1

6201

6201

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Testing of Transformer oil for dielectric break down strength.

1

850

851

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Insulating H.T. / LT copper / aluminium coils for Transformers.

1

428

428

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacing old and unserviceable gasket of top cover plate of transformer having 160KVA capacity

1

1062

1062

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacing old and unserviceable gasket of bushing for the following Transformer capacity 160KVA HT side

1

428

428

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacing old and unserviceable gasket of bushing for the following Transformer capacity 160KVA LT side

1

993

993

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Painting with 2 coats Zinchromate red oxide duly scraping existing paint followed by 2 coats of hammerton grey paint etc., complete for 160KVA Transformer

1

5353

5354

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacing L.T bushing for 160KVA distribution Transformer by new one.

7

222

1559

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacing L.T bushing metal parts for 160KVA distribution Transformer by new one.

1

669

669

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Drying the repaired transformer with appropriate heat / air for 160 KVA distribution Transformer

1

4015

4015

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Filteration of transformer oil as per ISS specifications filters to die electric strength above 40 KV at site

120

13

1636

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Providing Transformer oil tested as per IS-335 - 1972 (per Ltr)

100

160

16020

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacing the breather of the DTR/PTR.

1

2840

2840

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacing the Silica Gel in breather of the DTR / PTR.

2

2272

4545

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Transportation charges for shifting 160KVA Transformer from workshop at Patancheru Hyderabad to Mudigonda Intake station.

1

10000

10000

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Hire charges for engaging hydraulic lift (crane) with special T&P arrangement and for placing the transformer on the Transformer plinth at Mudigonda Intake station without any damage

1

5000

5000

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Rewinding of 160KVA Make Transformer HV side

1

113170

113170

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Supply, Transportation and Stinging of 100Sqmm ACSR Conductor Panther including binding with connectors and clamps with Hardware etc complete.

100

107

10777

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Supply, transportation and Erection of 11KV Lightening Arrestors station Type

3

2771

8315

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Supply and erecting porcelain Pin type insulator suitable for 11KV line with suitable hardware on existing cross arms.

3

389

1169

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;11 KV/22 KV Hand gloves

1

322

323

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;First Aid box 18" x 12" x 8"

1

1717

1718

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Danger Notice Plates of size 250X200mm, shall comply with IS:2551-1982.

10

324

3249

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Shock instrution chart in English / Hindi / Telugu duly framed with front glass.

1

654

654

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Supply of round bottom G.I sheet bucket of 9 Ltrs. Capacity as per IS:2546 made out of 24 gauge GI sheet with extra handle at bottom duly painted inside and red out side with printed with FIRE Mark for stand and hook and filled with sand and arranged to existing stand or hook

1

372

373

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Providing floor mounting stand for keeping 4No of fire bucket 1500mm length, 900mm height made out of 40x40x6mm angle iron welded with 4 hooks and duly painted with one coat of red lead and two coats of enamel paint.

1

1516

1517

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Supply, Transportation and fixing of 2x20W, 2000 lumens, 1200mm length LED retro tube light, housing made with alluminium anodised body, wide operating voltage with double side connection, PF=0.9, Surge protection: > 2KV, THD<15%, with inbuilt driver and frosted cover CCT: 3000K - 6500K as desired by the department and as per IS specifications, minimum CRI=80,.etc complete with 50,000 burning hours with BIS Certification. LUMINAIRE MAKE: Phillips / OSRAM / Wipro / Crompton / Bajaj / Havells / Jaquar / IB LED / Panasonic / Halonix / HPL / Syska / Eveready / Surya / Keselec. LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA / OSRAM / SAMSUNG / LG LEDs. including fixing on wall etc., including giving connections and all labour charges etc., complete. ( Data No.14-15-21.1.18 )

5

810

4050

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Dismantling of 315KVA (_____ make and s.No.____) existing old Distribution Transformer from existing double pole structure duly removing all connections etc complete

1

5000

5000

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Hire charges for engaging hydraulic lift(crane) with special T&P arrangement and keeping in the transport vehicle without any damage

1

5000

5000

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Transportation charges for shifting 315KVA Transformer from Mudigonda WTP to workshop at Patancheru Hyderabad

1

10000

10000

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Routine maintenance of transformer in operation covering insulation resistance oil, break down strength. Reconditioning / replacement of silicazel, cleaning of transformer and topping upto oil level if required (extra cost will be paid for oil).

1

6201

6201

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Testing of Transformer oil for dielectric break down strength.

1

850

851

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Insulating H.T. / LT copper / aluminium coils for Transformers.

1

428

428

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacing old and unserviceable gasket of top cover plate of transformer having 150KVA capacity

1

1062

1062

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacing old and unserviceable gasket of bushing for the following Transformer capacity 315KVA HT side

1

428

428

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacing old and unserviceable gasket of bushing for the following Transformer capacity 315KVA LT side

1

993

993

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Painting with 2 coats Zinchromate red oxide duly scraping existing paint followed by 2 coats of hammerton grey paint etc., complete for 315KVA Transformer

1

5353

5354

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacing L.T bushing for 315KVA distribution Transformer by new one.

7

222

1559

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacing L.T bushing metal parts for 315KVA distribution Transformer by new one.

1

669

669

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Drying the repaired transformer with appropriate heat / air for 315 KVA distribution Transformer

1

4015

4015

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Filteration of transformer oil as per ISS specifications filters to die electric strength above 40 KV at site

120

13

1636

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Providing Transformer oil tested as per IS-335 - 1972 (per Ltr)

200

160

32039

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacing the breather of the DTR/PTR.

1

2840

2840

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacing the Silica Gel in breather of the DTR / PTR.

2

2272

4545

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Transportation charges for shifting 150KVA Transformer from workshop at Patancheru Hyderabad to Jamalapuram Pumping station.

1

10000

10000

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Hire charges for engaging hydraulic lift (crane) with special T&P arrangement and for placing the transformer on the Transformer plinth at Mudigonda WTP station without any damage

1

5000

5000

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Rewinding of 315KVA Make Transformer HV side

1

207478

207478

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Supply, Transportation and Stinging of 100Sqmm ACSR Conductor Panther including binding with connectors and clamps with Hardware etc complete.

100

107

10777

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Supply, transportation and Erection of 11KV Lightening Arrestors station Type

3

2771

8315

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Supply and erecting porcelain Pin type insulator suitable for 11KV line with suitable hardware on existing cross arms.

3

389

1169

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;11 KV/22 KV Hand gloves

2

322

645

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;First Aid box 18" x 12" x 8"

5

1717

8589

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Danger Notice Plates of size 250X200mm, shall comply with IS:2551-1982.

10

324

3249

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Shock instrution chart in English / Hindi / Telugu duly framed with front glass.

2

654

1309

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Supply of round bottom G.I sheet bucket of 9 Ltrs. Capacity as per IS:2546 made out of 24 gauge GI sheet with extra handle at bottom duly painted inside and red out side with printed with FIRE Mark for stand and hook and filled with sand and arranged to existing stand or hook

1

372

373

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Providing floor mounting stand for keeping 4No of fire bucket 1500mm length, 900mm height made out of 40x40x6mm angle iron welded with 4 hooks and duly painted with one coat of red lead and two coats of enamel paint.

1

1516

1517

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Kirloskar Motor Make 415Volts,50Hz,22 KW,50HP,1470Rpm,37 Amps total rewinding work and repalce connectors .

3

71913

215740

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Kirloskar Motor Make 415Volts,50Hz,30KW,40HP,1470Rpm,54.50 Amps total rewinding work and repalce connectors .

3

51667

155001

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out Bearing End cover by new supply and fixing of Bearing End cover

12

4612

55354

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Refixing of Bearing Housing

12

6401

76817

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out Bearing by new supply and fixing of Bearing .

12

1002

12032

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out Coupling Key by new supply and fixing of Coupling Key .

12

360

4323

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out Gland by new supply and fixing of Gland .

12

15320

183843

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out Impeller Key by new supply and fixing of Impeller Key .

6

543

3264

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Refixing of Old Impeller.

6

160831

964989

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out Lock Nut by new supply and fixing of Lock Nut .

12

442

5313

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out Loggging ring by new supply and fixing of Loggging ring .

12

927

11134

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out Neck ring by new supply and fixing of Neck ring .

12

24907

298894

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out Shaft protection Cap by new supply and fixing of Shaft protection Cap .

12

314

3769

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out Shaft with key by new supply and fixing of Shaft with key.

12

9756

117077

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out Sleeve Nut by new supply and fixing of Sleeve Nut.

12

1112

13352

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out Sleeve O Ring by new supply and fixing of Sleeve O Ring.

12

727

8732

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out Sleeve by new supply and fixing of Sleeve .

12

6905

82863

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out Spacer Sleeve by new supply and fixing of Spacer Sleeve .

12

1332

15992

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out Thrust collar/Brg Spacer/Brg dist sleeve by new supply and fixing of Thrust collar/Brg Spacer/Brg dist sleeve .

12

992

11913

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out Water Thrower by new supply and fixing of Water Thrower.

12

837

10052

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out contactor by new supply and fixing of ML 6 Contactors L&T make

5

16879

84398

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out Timer by new supply and fixing of Timer Range 2.5 Mylon

4

1175

4701

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out Mini preventer by new supply and fixing of Mini preventer VSP3

4

896

3585

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out 22/50 Motor Protection Relay by new supply and fixing of 22/50 Motor Protection Relay L&t Make

4

7670

30683

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out 20 A bullet proof fuse links by new supply and fixing of 20 A bullet proof fuse links

1

236

237

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out 125/5A CT Coils by new supply and fixing of 125/5A CT Coils for motors

5

726

3634

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out Push Buttons (on/OFF) by new supply and fixing of Push Buttons (on/OFF) for Motor

5

243

1219

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out Indicator by new supply and fixing of Indicator Red

5

256

1281

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out 25 Sqmm 1C CU flexible cable multistrand by new supply and fixing of 25 Sqmm 1C multistrand

50

404

20229

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out FN 160 with handle by new supply and fixing of FN 160 with handle for Motor Feeder L& T make

4

7415

29664

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out 160 A HRC Fuses by new supply and fixing of 160 A HRC Fuses L&T Make

5

453

2269

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out 35 Sqmm Al Lugs by new supply and fixing of 35 Sqmm Al Lugs

15

47

709

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out 25 Sqmm Cu Lugs by new supply and fixing of 25 Sqmm Cu Lugs

10

61

611

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out 160 DN (160 A) 3 P MCCB 36 kA by new supply and fixing of 160 DN MCCB

1

16343

16344

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out 3P Speader links by new supply and fixing

1

886

886

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out DN2 Extended Rotary Handle by new supply and fixing

1

1169

1170

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out 10 KVAR Power Capacitor L&t Make by new supply and fixing

15

2798

41971

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out 100/5A CT Coils by new supply and fixing of CT Coils

1

438

438

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out 2 A Fuses by new supply and fixing of 2 A Fuses

10

110

1104

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out 2-32 A Fuse Holders by new supply and fixing of 2-32 A Fuse holder

10

212

2125

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out 1 sqmm FRLS by new supply and fixing of 1sqmm FRLS Cable

150

29

4462

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out 1.5 sqmm FRLS by new supply and fixing of 1.5sqmm FRLS Cable

150

40

6086

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out 6 Way SPN DB by new supply and fixing of 6 Way SPN DB

1

1325

1325

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out 6A SP MCB by new supply and fixing of 6A SP MCB

5

365

1828

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out 12 Way SPN DB by new supply and fixing of 12 Way SPN DB

1

2760

2761

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out 16A SP MCB by new supply and fixing of 12 Way SPN DB

3

365

1097

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out 60W street light by new supply and fixing of 60W street light

15

5244

78663

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Supply of round bottom G.I sheet bucket of 9 Ltrs. Capacity as per IS:2546 made out of 24 gauge GI sheet with extra handle at bottom duly painted inside and red out side with printed with FIRE Mark for stand and hook and filled with sand and arranged to existing stand or hook

2

372

745

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Providing floor mounting stand for keeping 4No of fire bucket 1500mm length, 900mm height made out of 40x40x6mm angle iron welded with 4 hooks and duly painted with one coat of red lead and two coats of enamel paint.

2

1516

3034

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Supply, Transportation and fixing of 2x20W, 2000 lumens, 1200mm length LED retro tube light, housing made with alluminium anodised body, wide operating voltage with double side connection, PF=0.9, Surge protection: > 2KV, THD<15%, with inbuilt driver and frosted cover CCT: 3000K - 6500K as desired by the department and as per IS specifications, minimum CRI=80,.etc complete with 50,000 burning hours with BIS Certification. LUMINAIRE MAKE: Phillips / OSRAM / Wipro / Crompton / Bajaj / Havells / Jaquar / IB LED / Panasonic / Halonix / HPL / Syska / Eveready / Surya / Keselec. LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA / OSRAM / SAMSUNG / LG LEDs. including fixing on wall etc., including giving connections and all labour charges etc., complete. ( Data No.14-15-21.1.18 )

40

810

32403

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Supply and fixing of Co2 4.5 Kg capacity type extinguisher with initial filling in brand new cylinder with powder coated finish, fitted with Gun metal union, high pressure, discharge hose, wall mounting bracket / stand etc. complete, confirming to IS:15683. electrical room. Makes : FIREX /MINIMAX/ ARMOUR /SAFEX/ KANNEX / CEASEFIRE

4

4834

19337

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;11 KV/22 KV Hand gloves

1

322

323

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;First Aid box 18" x 12" x 8"

5

1717

8589

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Danger Notice Plates of size 250X200mm, shall comply with IS:2551-1982.

2

324

650

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Shock instrution chart in English / Hindi / Telugu duly framed with front glass.

3

654

1963

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Removing & refixing the 3HP Booster pump after repairing of existing horizontal mounting/ monoblock pump with following spares, etc. including aligning of pump with reference to motor & running the pump on load.

5

3456

17281

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Supply, Transportation and fixing of of 50W LED Flood light Luminaire made of pressure die cast aluminum housing with powder coated, having toughened glass cover, Suitable lens on LEDs, IP 66 (Silicon gasket ensures Optical & Electrical compartments are IP 66 )protected, wide operating voltage range , P.F > 0.90, System having efficacy >110 lumens/watt, with Ingress protection IP66, Driver surge protection >10KV, THD<15%, CCT: 3000- 6500K as desired by the department and as per IS, CRI>70, Inbuilt Electrical protections like Over voltage, short circuit, Over load, Open Circuit, Miswiring, etc complete with BIS certification with 5 years warranty. The contractor has to furnish the manufacturer warranty letter, LM 79 and LM 80 certificates. LUMINAIRE MAKE : PHILIPS / OSRAM / GE Venture / CROMPTON / BAJAJ / Surya / Wipro / Jaquar / Eveready / Halonix / Keselec / HAVELLS / POLYCAB / SURYA / SYSKA./ Capart / Fortune Arrt / FIEM / Arraystorm / GM / Goldmedal / Panasonic / Silicon / Leksa / Orient / HPL / Valmont / Transrail LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA / OSRAM / SAMSUNG / LG LEDs.

8

7466

59734

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Repair of existing Indoor MS panel board by welding the damaged broken panel board doors body sheet, angle iron, frame door hinges, cement concrete to panel board legs, embossing (letters & RR No.) etc., complete

1

3259

3260

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Supply, Transportation and fixing of 2x20W, 2000 lumens, 1200mm length LED retro tube light, housing made with alluminium anodised body, wide operating voltage with double side connection, PF=0.9, Surge protection: > 2KV, THD<15%, with inbuilt driver and frosted cover CCT: 3000K - 6500K as desired by the department and as per IS specifications, minimum CRI=80,.etc complete with 50,000 burning hours with BIS Certification. LUMINAIRE MAKE: Phillips / OSRAM / Wipro / Crompton / Bajaj / Havells / Jaquar / IB LED / Panasonic / Halonix / HPL / Syska / Eveready / Surya / Keselec. LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA / OSRAM / SAMSUNG / LG LEDs. including fixing on wall etc., including giving connections and all labour charges etc., complete. ( Data No.14-15-21.1.18 )

25

810

20252

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Supply and fixing of Co2 4.5 Kg capacity type extinguisher with initial filling in brand new cylinder with powder coated finish, fitted with Gun metal union, high pressure, discharge hose, wall mounting bracket / stand etc. complete, confirming to IS:15683. electrical room. Makes : FIREX /MINIMAX/ ARMOUR /SAFEX/ KANNEX / CEASEFIRE

2

4834

9669

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Supply and fixing of PVC synthetic elastomer electrically insulated mat conforming to IS: 15652-2006 with Class B insulation having 2.5mm thickness upto 11KV

5

5373

26870

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Repairs tp 20HP Glory Technologies make Air blower with 1450RPM Cap:860m3/hr

2

16287

32576

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Rewinding of electric motor Primo make 20 HP three phase 1450 RPM of all types and makes with copper wire, overhauling with minor repairs, testing for the original speed and no load consumption .

2

21151

42302

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Removing and refixing the 415 v 50 hz III phase 15HP /20HP capacity Air blower motor suitable speed horizontal foot mounted screen protected drip proof continous rated squrrel cage induction motor with F class insulation, class H super enamelled copper wire with as per standards including transportation charges etc

2

19128

38256

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Supply of Single compression brass cable glands for 2 core XLPE armoured cable for 4Sqmm with brass washers complete.

200

208

41617

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Supply M S Bolts / Nuts / Washers

20

101

2022

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Supply Structural steel angle / channel / beam / bars

0.5

69305

34653

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Supply 100 mm Dia MS Pipe 6mm

10

2274

22750

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;100mm x 25mm x 2mm thk PERFORATED CABLE TRAYS

30

666

20008

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Mechanical Items Butterfly Valve

4

50000

200000

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;ABB Make 415Volts,50Hz,75 KW,100HP,1475Rpm,132.50 Amps total rewinding work and repalce connectors .

3

111865

335596

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out Bearing End cover by new supply and fixing of Bearing End cover

2

4612

9226

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Refixing of Bearing Housing

2

6401

12803

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out Bearing by new supply and fixing of Bearing .

2

1002

2005

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out Coupling Key by new supply and fixing of Coupling Key .

2

360

721

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out Gland by new supply and fixing of Gland .

2

15320

30641

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out Impeller Key by new supply and fixing of Impeller Key .

2

543

1088

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Refixing of Old Impeller.

2

160831

321663

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out Lock Nut by new supply and fixing of Lock Nut .

2

442

886

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out Loggging ring by new supply and fixing of Loggging ring .

2

927

1856

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out Neck ring by new supply and fixing of Neck ring .

2

24907

49816

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out Shaft protection Cap by new supply and fixing of Shaft protection Cap .

2

314

628

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out Shaft with key by new supply and fixing of Shaft with key.

2

9756

19513

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out Sleeve Nut by new supply and fixing of Sleeve Nut.

2

1112

2225

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out Sleeve O Ring by new supply and fixing of Sleeve O Ring.

2

727

1455

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out Sleeve by new supply and fixing of Sleeve .

2

6905

13811

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out Spacer Sleeve by new supply and fixing of Spacer Sleeve .

2

1332

2665

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out Thrust collar/Brg Spacer/Brg dist sleeve by new supply and fixing of Thrust collar/Brg Spacer/Brg dist sleeve .

2

992

1986

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out Water Thrower by new supply and fixing of Water Thrower.

2

837

1675

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out contactor by new supply and fixing of ML 6 Contactors L&T make

4

16879

67518

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out Timer by new supply and fixing of Timer Range 2.5 Mylon

2

1175

2350

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out Mini preventer by new supply and fixing of Mini preventer VSP3

4

896

3585

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out 22/50 Motor Protection Relay by new supply and fixing of 22/50 Motor Protection Relay L&t Make

4

7670

30683

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out 20 A bullet proof fuse links by new supply and fixing of 20 A bullet proof fuse links

4

236

947

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out 125/5A CT Coils by new supply and fixing of 125/5A CT Coils for motors

4

726

2908

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out Push Buttons (on/OFF) by new supply and fixing of Push Buttons (on/OFF) for Motor

12

243

2924

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out Indicator by new supply and fixing of Indicator Red

2

256

512

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out 25 Sqmm 1C CU flexible cable multistrand by new supply and fixing of 25 Sqmm 1C multistrand

10

404

4046

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out FN 160 with handle by new supply and fixing of FN 160 with handle for Motor Feeder L& T make

4

7415

29664

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out 160 A HRC Fuses by new supply and fixing of 160 A HRC Fuses L&T Make

9

453

4085

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out 35 Sqmm Al Lugs by new supply and fixing of 35 Sqmm Al Lugs

12

47

567

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out 25 Sqmm Cu Lugs by new supply and fixing of 25 Sqmm Cu Lugs

12

61

733

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out 160 DN (160 A) 3 P MCCB 36 kA by new supply and fixing of 160 DN MCCB

1

16343

16344

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out 3P Speader links by new supply and fixing

1

886

886

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out DN2 Extended Rotary Handle by new supply and fixing

1

1169

1170

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out 10 KVAR Power Capacitor L&t Make by new supply and fixing

3

2798

8394

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out 100/5A CT Coils by new supply and fixing of CT Coils

5

438

2191

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out 2 A Fuses by new supply and fixing of 2 A Fuses

1

110

110

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out 2-32 A Fuse Holders by new supply and fixing of 2-32 A Fuse holder

1

212

212

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out 1 sqmm FRLS by new supply and fixing of 1sqmm FRLS Cable

150

29

4462

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out 1.5 sqmm FRLS by new supply and fixing of 1.5sqmm FRLS Cable

150

40

6086

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out 6 Way SPN DB by new supply and fixing of 6 Way SPN DB

1

1325

1325

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out 6A SP MCB by new supply and fixing of 6A SP MCB

10

365

3656

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out 12 Way SPN DB by new supply and fixing of 12 Way SPN DB

1

2760

2761

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out 16A SP MCB by new supply and fixing of 12 Way SPN DB

10

365

3656

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Replacement of Old warn out 60W street light by new supply and fixing of 60W street light

10

5244

52442

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Supply of round bottom G.I sheet bucket of 9 Ltrs. Capacity as per IS:2546 made out of 24 gauge GI sheet with extra handle at bottom duly painted inside and red out side with printed with FIRE Mark for stand and hook and filled with sand and arranged to existing stand or hook

1

372

373

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Providing floor mounting stand for keeping 4No of fire bucket 1500mm length, 900mm height made out of 40x40x6mm angle iron welded with 4 hooks and duly painted with one coat of red lead and two coats of enamel paint.

1

1516

1517

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Supply and fixing of Co2 4.5 Kg capacity type extinguisher with initial filling in brand new cylinder with powder coated finish, fitted with Gun metal union, high pressure, discharge hose, wall mounting bracket / stand etc. complete, confirming to IS:15683. electrical room. Makes : FIREX /MINIMAX/ ARMOUR /SAFEX/ KANNEX / CEASEFIRE

2

4834

9669

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Supply, Transportation and fixing of 2x20W, 2000 lumens, 1200mm length LED retro tube light, housing made with alluminium anodised body, wide operating voltage with double side connection, PF=0.9, Surge protection: > 2KV, THD<15%, with inbuilt driver and frosted cover CCT: 3000K - 6500K as desired by the department and as per IS specifications, minimum CRI=80,.etc complete with 50,000 burning hours with BIS Certification. LUMINAIRE MAKE: Phillips / OSRAM / Wipro / Crompton / Bajaj / Havells / Jaquar / IB LED / Panasonic / Halonix / HPL / Syska / Eveready / Surya / Keselec. LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA / OSRAM / SAMSUNG / LG LEDs. including fixing on wall etc., including giving connections and all labour charges etc., complete. ( Data No.14-15-21.1.18 )

30

810

24302

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Supply of Single compression brass cable glands for 2 core XLPE armoured cable for 4Sqmm with brass washers complete.

100

208

20809

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;150mm x 50mm x 2mm thick LADDER TYPE CABLE TRAYS

100

396

39623

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Supply Structural steel angle / channel / beam / bars

1

69305

69305

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Removel of Existing sand & Aggregrate and depositing on bank with an initial lead and lift of rapid sand filter beds including all labour charges etc..complete and disposting it 1.0km away from the Plant complete as per specification

85.08

2136

181755

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Laying of Gravel Layers for filtermedia to RS filters including all labour charges for screening washing laying in filters etc., complete.

31.5

7558

238095

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Laying filtermedia for slightly coarser sand size0.45mm to 0.70mm with uniformity co-efficent is 1.60 including cost and conveyence of all materials and all labour charges for screeing ,washing & laying etc. Complete

47.25

8205

387694

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Scarifying existing granular surface to a depth of 50 mm and disposal of scarified material with a lift upto 3 m and leads upto 1000 m as per Technical Specification Clause 301.4. MORD, But excluding GST.

784.5

30

23905

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Construction of granular sub-base by providing well graded material / Close graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller 80-100 kN / Vibratory Roller to achieve the desired density, complete as per Technical Specification Clause 401 MORD / MORTH.

784.5

1497

1174538

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Construction of plain cement concrete pavement, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 adopting Nominal Mix 1:2:4 Proportion equivalent to M20 Grade, coarse and fine aggregates conforming to IS : 383, maximum in a concrete mixer of not less than 0.2 cum capacity and appropeiate weigh batcher, laid in approved fixed side formwork (steel channel, laying and fixing of 125 mictron thick polythene film, wedges, steel plates including levelling the formwork), spreading the concrete with sholvels, rakes, compacted using needle and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, admixtures as approved, curing of concrete slabs for 14- days, curing compound (where specified) and water finishing to lines and grade as per Technical Specification Clause 1501 MORD.

156.9

6165

967367

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Collection& Supply of natural occuring Gravel on road side with dept.guage including spreading as per drawing and technical specification Clause 305.3.9 MORD & 304 MORTH for Shoulders

675

494

333909

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Painting to New External Walls with two coats of Plastic Emulsion paint of Asian / Berger / Nerolac / Saicoat / Endocem or equalent quality of approved brand and shade at Intakewell

635.53

2100

133493

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Painting to New External Walls with two coats of Plastic Emulsion paint of Asian / Berger / Nerolac / Saicoat / Endocem or equalent quality of approved brand and shade at 850 KL sump

161.57

2100

33938

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Painting to New External Walls with two coats of Plastic Emulsion paint of Asian / Berger / Nerolac / Saicoat / Endocem or equalent quality of approved brand and shade at Pump house at HW - 12 x 6m

596

2100

125190

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Painting with best Synthetic enamil paint in two coats over a primary coat with redoxide in single coat including cost and conveyance of all materials and labour chares etc., complete.

30.48

1236

3767

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Painting to New External Walls with two coats of Plastic Emulsion paint of Asian / Berger / Nerolac / Saicoat / Endocem or equalent quality of approved brand and shade at Store Room at HW

248.62

2100

52223

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Painting with approved colour ready mixed enamel paint two coats to M.S doors and windows including cost and conveyance of all materials and labour chares etc., complete.

19.03

1236

2352

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Snowcem painting two coats over a single coat white whasing primary including cost and conveyence of all materials and labour charges etc complete @ Watchman Quarters at HW

481.78

2100

101198

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Painting with best Synthetic enamil paint in two coats over a primary coat with redoxide in single coat including cost and conveyance of all materials and labour chares etc., complete.

47.12

1236

5824

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Painting to New External Walls with two coats of Plastic Emulsion paint of Asian / Berger / Nerolac / Saicoat / Endocem or equalent quality of approved brand and shade at 8.00 MLD RSF

2952.2

2100

620110

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Painting with best Synthetic enamil paint in two coats over a primary coat with redoxide in single coat including cost and conveyance of all materials and labour chares etc., complete.

36.86

1236

4556

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Supply,Delivery,Installation of Aquaflow make 5kg/Hr capacity vaccum type gaseous wall mounted chlorinator for post/pre Chlorination in water treatment Plant with following A) Wall mounted filter cum liquid trapper with isolated control valve B) Vaccum regulator with 5Kg/Hr Cap ROTA-Meter C) 3 Meter length cooper tube with end fittings D) Clamp and operating key for cylinder valveE) Injector with water pressure guage at size of 1" In & outlet

1

156000

156000

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Chlorine leak detector with single point sensor digital readout, hooter etc, range of 0-10 PPM Chlorine in air type sensor electrochemical/dry cell3.5" Digital display with 7 segment LED 230V AC power supply.

1

78000

78000

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Breathing apparatus for emergency chlorine leak arrest like oxygen cylinder with mask as per BIS regularity

1

85000

85000

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Chlorine cylinder leak arrest equipment with goggles, gloves, mask, as per BIS standards

1

85000

85000

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;32mm size UPVC pipeline from chlorinator to sump with required accessories like valves, FTAs, MTAs, L bends, couplings, Non return valves, Y type strainer including transportation etc.

1

35000

35000

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Cost, supply, Installation and commisioning of 900 Kg Chlorine Gas chlorine tonner including transportation with necessary Explosive certificates and including all taxes etc. complete.

2

168000

336000

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Cost , supply and laying & jointing of 50 mm dia. GI pipes B class for water line by gravity from OHBR to Chlorine gas vaccum pump including cost and conveyance of all materials and labour charges wtc. Complete.

25

589

14742

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Cost, supply and fixing of 80x80x50 mmdia. DI all flanged T with 80 mm dia. Sluice valve

1

11481

11481

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH

5.79

225

1304

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Cement concrete (1:4:8)prop using 40 mm gauge HG metal including cost &conveyance of all materials and labour charges ,seigniorage charges using concret mixer etc complete

3.96

5230

20738

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Flooring with CC ( 1:2:4) mix using 20mm HG metal incl.c/c of all materilas and all labour charges etc., complete

3.6

8846

31846

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Laying of column footings with RCC M20 Mix concrete by uisng 20 mm HGMC metal including cost and conveyance of all materials and labour ahcrges etc. Complete.

0.34

9585

3235

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;RCC M20 Nominal using 20mm HBG metal including cost and conveyance of all material, labour charges, centering etc., complete but excluding cost of steel and its fabrication charges

0.63

13536

8593

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Cost of steel and its fabrication charges incl., bending, cost of binding wire etc., complete

0.3

86461

25938

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;cost, supply and fixing of 65 mm dia. GI pipe B class for rafters to GI corrugated roof incluidng cost and conveyance of all materials and labour charges etc. Complete.

27

1102

29756

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;cost, supply and fixing of 40 mm dia. GI pipe B class for purlins to GI corrugated roof incluidng cost and conveyance of all materials and labour charges etc. Complete.

30

579

17383

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Roofing with corrugated G.I sheets 1.25mm thick fixed with G.I ?J? bolts & nuts 8 mm dia with bitumen & G.I limpet washers filled with white lead & including a coat of approved steel primer and two coats of approved paint on over lapping of sheets complete (upto a pitch of 600 ) and seigniorage charges, turnover tax etc., complete, excluding the cost of purlins, rafters, trusses & cost of conveyance of all materials

27

1557

42047

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Removing old CLF Bridge and specials / fittings/Motors and cleaning, scraping the pipes, hoisting and keeping with in 100m lead consider output of 2.5T

1096.33

21

23682

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Removal of wet silt and sludge from sullage drains, with aid of baskets

155.03

587

91091

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Cost and supply of stainless steel Angular bars for flocculator bridge Excluding Of welding and including transportation charges etc.. Complete of Grade 304 Grade

1892.65

718

1359011

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Cost, supply and fabricating all heavy steel works like Trusses, Stanchions,Heavy Beams and Girders including cost of welding rods, power charges, etc excluding cost of fixing in position including cost and conveyance of all materials and labour charges etc. complete. Intake well base plate and dimmy ect.

113.37

146

16616

... More
Revival of Non integrated Comprehensive Protected Water Supply (CPWS) Scheme;Fixing of CLF Center Bearing CLF Bridge Including Labour Charges etc. Complete.

235

249

58738



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.