Mishra Dhatu Nigam Limited Tender
For getting the details of etenders, if you are looking for information about them from the cumbersome government websites but are tired of doing so, Bidassist comes up with a one stop solution. It collates every Eproc telangana tender on Bidassist. One can approach it for the bidding process, registration process, etc., are explained below.
Costs
EMD
₹ 60,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_MDN_93935_1Tender No
AP20231034/EADVT/504/23-24Tender Authority
Mishra Dhatu Nigam Limited ViewPurchaser Address
-Website
http://http://midhani-india.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Providing and laying in position cement concrete of specified grade, 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) etc complete as directed by EIC
13
-
-
Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20mm nominal size derived from natural sources) etc complete as directed by EIC
48
-
-
Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) et complete as directed by EIC
80
-
-
Coursed rubble masonry with hard stone (first sort) in superstructure above plinth level and upto floor five level. Masonry work (first sort), in cement mortar 1:6 (1 cement : 6 coarse sand) etc complete as directed by EIC
180
-
-
Centering and shuttering including strutting, propping etc. and removal of form work for Foundations, footings, bases for columns etc complete as per instructions of EIC
17
-
-
Centering and shuttering including strutting, propping etc. and removal of form work for Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc
85
-
-
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more
1750
-
-
Providing and laying Concrete of M25 grade (with minimum cement content of 330 kg /cum) in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, OPC, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement etc complete as per direction of the engineer-in-charge.
16
-
-
Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) Flush/ Ruled pointing
800
-
-
Backfilling in all positions at all heights and depths and descents in foundations, pits, pipe trenches, tunnels, sewer lines, around foundations and structures, in plinth etc with approved excavated material, soil, soft disintegrated rock obtained within a lead of 50m including reclaiming from spoil heaps at all heights, or reclaiming from dump at all depths, transporting, depositing, watering, well ramming, compacting, spreading levelling and dressing complete all as per drawings, specifications and directions of the Engineer in charge, all tools, plant, machineries, transportation and labour complete. Backfilling in layers not exceeding 200 mm thickness including dozing, levelling, dressing and compacting with hand compactors/mechanical compactors/plate compactors/vibro rollers to the density of 95% at optimum moisture content complete in all respects as directed by the Engineer in charge.
165
-
-
Labour
-
-
-
Skilled
6
-
-
Unskilled
10
-
-
Evaluation Notes How It Works ?