Military Engineer Services Tender
... More
The MES has issued a formal invitation for competitive bids for the Military Engineer Services project, for Provision Of Additional 5 Mva Electrical Power At Chess Vignyankancha Hyderabad in Ranga Reddy, Telangana, with an estimated contract value of Rs. 10,44,00,000. The bid opening date for this tender is 15-05-2025 and the last date for bid submission is 19-06-2025. Interested bidders for Military Engineer Services tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.
Military Engineer Services - MES Tender
Energy, Oil and Gas
Electrical Goods and Equipments
Electrical and Electronics
Eprocure
Opening Date15 May 2025
Closing Soon19 Jun 2025
Tender Amount₹ 10,44,00,000
AI Insights
Technical
Technical
Class Of Bidder
... View More
The eligible class required by a bidder to participate in the tender is 'Class S'.
Technical Capacity
... View More
The required prior work experience for the bidder is not explicitly stated, but it is mentioned that contractors of one class below the eligible class may bid if they have previously completed similar works satisfactorily. For contractors not enlisted with certain organizations, the bidder should have satisfactorily completed a requisite value of similar nature works, but specific values like amount and percentage are not mentioned. Therefore, the information on the value and percentage of similar works completed is not available.
Costs
EMD
₹ 8,47,000Document Cost
₹ 3,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_708387_1Tender No
84039Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
PROVISION OF ADDITIONAL 5 MVA ELECTRICAL POWER AT CHESS VIGNYANKANCHA HYDERABAD
PROVISION OF ADDITIONAL 5 MVA ELECTRICAL POWER AT CHESS VIGNYANKANCHA HYDERABAD
PROVISION OF ADDITIONAL 5 MVA ELECTRICAL POWER AT CHESS VIGNYANKANCHA HYDERABAD
PROVISION OF ADDITIONAL 5 MVA ELECTRICAL POWER AT CHESS VIGNYANKANCHA HYDERABAD
BOQ Items
... More
Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part - IV representing __________ % ____________ percent Above / Below the lump sum price of ₹19,586.30 inserted by the MES in Schedule ‘A’ Part - IV
1
19586
19586.3
... More
Lump sum price worked out by the Contractor for “ROADS / PATH/ HARDSTANDING ” as listed in Schedule ‘A’ Part - V representing ________ % ____________ percent Above / Below the lump sum price of ₹1,57,269.51 inserted by the MES in Schedule ‘A’ Part - V
1
157269
157269.51
... More
Lump sum price worked out by the Contractor for “SEWAGE DISPOSAL” as listed in Schedule ‘A’ Part - VI representing _________ % __________________ percent Above / Below the lump sum price of `1,54,878.90 inserted by the MES in Schedule ‘A’ Part - VI
1
154878
154878.9
... More
Lump sum price worked out by the Contractor for “AREA DRAINAGE” as listed in Schedule ‘A’ Part - VII representing __________ % _________________ percent Above / Below the lump sum price of ₹4,85,748.85 inserted by the MES in Schedule ‘A’ Part - VII
1
485748
485748.85
... More
Lump sum price worked out by the Contractor for “RCC RETAINING WALL” as listed in Schedule ‘A’ Part - VIII representing __________ % _________________ percent Above / Below the lump sum price of ₹8,93,835.50 inserted by the MES in Schedule ‘A’ Part - VIII
1
893835
893835.5
... More
Lump sum price worked out by the Contractor for “CHAIN LINK FENCING” as listed in Schedule ‘A’ Part - IX representing __________ % _________________ percent Above / Below the lump sum price of ₹2,74,117.47 inserted by the MES in Schedule ‘A’ Part - IX
1
274117
274117.47
... More
Lump sum price worked out by the Contractor for “EXTERNAL ELECTRIC SUPPLY” as listed in Schedule ‘A’ Part - X representing __________ % ____________ percent Above / Below the lump sum price of ₹4,03,47,466.12 inserted by the MES in Schedule ‘A’ Part - X
1
40347466
40347466.12
... More
Lump sum price worked out by the Contractor for “EXTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part - XI representing _______ % _________________ percent Above / Below the lump sum price of `87,030.46 inserted by the MES in Schedule ‘A’ Part - XI
1
87030
87030.46
... More
Schedule 'A' Part-XII
This Schedule is not prepriced by MES and the prepriced rate indicated in Col - 5 as ₹0.00 indicates this fact only. The tenderer is required to quote their rates in Column 6. This Schedule constitutes Sl. Item Nos. 13.00 to 29.00.
-
-
-
... More
EXTERNAL ELECTRIC SUPPLY
Supply, installation, Testing and Commissioning of Transformer Step down outdoor type of capacity 3000 KVA complete with all standard accessories /fittings suitable for HT 11 KV 3 Phase and LT 433 volts 3 Phase 4 wire 50 Hz frequency, copper wound, with on load tapping switch and variation of secondary voltage +5% to -15% in steps of 1.25% continous rating with temperature rise of 50/55 degree ceisious conforming to IS 2099, IS 3347 and conventional/herimetical sealed with and including following accessories with SCADA compatability complete all as specified and directed.
(a) RTCC Panels as per required specification shall be designed by OEMs.
(b) Necessary extension / adaptor boxes at LV side shall be suitable for bus duct and HV side shall be suitable for HT UG cable shall be designed as per specifications.
(c) Oil conservator with filter type drain valve and oil level.
1
-
-
... More
(d) Dehydrating breather with first fill of dehydrating agent.
(e) Pressure Release Valve.
(f) Thermometer with pocket on tank cover
(g) Rating plate and terminal marking plate.
(h) Oil filling hole with cap / plug with connection plate complete.
(j) Air release valve
(k) Drain outlet pipe with brass gate valve and dummy plug.
(l) Initial filling of transformer oil upto recommended level confirming to IS 335.
(m) ONAN type cooling, vector group : DYN 11
(n) Double float Buchholtz relay with alarm and trip contacts including control cable of copper conductor as per OEM standard from Marshalling box to Relay of VCB / Hooter for relevant fault alarming. Buchholtz relay shall be provided with 2 shut off brass valves at ends.
(o) 150mm dia winding temperature indicator, dial type with alarm and trip contacts with SCADA compatability.
-
-
-
... More
(p) 150mm dia oil temperature indicator, dial type with alarm and trip contacts with SCADA compatability and 04 Nos lifting hook / lugs.
(q) Test Report / on site inspection report shall be provided by OEM to EIC.
(r) Marshalling box with double window, space heater element with switch, illumination CFL lamps, 16/6A socket completely prewired.
(s) Neutral to be brought outside on the body of Transformer.
(t) Neutral CT shall be provided. (u) Quoted rate include necessary foundation and Railing required for transformer as specified and directed by Eng-in-charge.
-
-
-
... More
Supply, installation, Testing and Commissioning of Transformer Step down outdoor type of capacity 2500 KVA complete with all standard accessories /fittings suitable for HT 11 KV 3 Phase and LT 433 volts 3 Phase 4 wire, copper wound, with on load tapping switch and variation of secondary voltage +7.5% to -7.5% in steps of 2.5% continous rating with temperature rise of 40/45 degree ceisious conforming to IS-1180-2014 Level-2 and conventional/herimetical sealed with and including following accessories with SCADA compatability complete all as specified and directed.
(a) RTCC Panels as per required specification shall be designed by OEMs.
(b) Necessary extension / adaptor boxes at LV side shall be suitable for bus duct and HV side shall be suitable for HT UG cable shall be designed as per specifications.
(c) Oil conservator with filter type drain valve and oil level.
(d) Dehydrating breather with first fill of dehydrating agent.
(e) Pressure Release Valve.
1
-
-
... More
(f) Thermometer with pocket on tank cover
(g) Rating plate and terminal marking plate.
(h) Oil filling hole with cap / plug with connection plate complete.
(j) Air release valve
(k) Drain outlet pipe with brass gate valve and dummy plug.
(l) Initial filling of transformer oil upto recommended level confirming to IS 335.
(m) ONAN type cooling, vector group : DYN 11
(n) Double float Buchholtz relay with alarm and trip contacts including control cable of copper conductor as per OEM standard from Marshalling box to Relay of VCB / Hooter for relevant fault alarming. Buchholtz relay shall be provided with 2 shut off brass valves at ends.
(o) 150mm dia winding temperature indicator, dial type with alarm and trip contacts with SCADA compatability.
(p) 150mm dia oil temperature indicator, dial type with alarm and trip contacts with SCADA compatability and 04 Nos lifting hook / lugs.
(q) Test Report / on site inspection report shall be provided by OEM to EIC.
(r) Marshalling box with double window, space heater element with switch, illumination CFL lamps, 16/6A socket completely prewired.
(s) Neutral to be brought outside on the body of Transformer.
(t) Neutral CT shall be provided. (u) Quoted rate include necessary foundation and Railing required for transformer as specified and directed by eng-in-charge.
-
-
-
... More
S&F Compact Low Tension Aluminium Sandwich type Busbar trunking system 5000A, 433V Sandwich type 3 Phase +100% Neutral and equipped with integral protective earth conductor of aluminium alloy with cross section not less than 50% of phase conductor in accordance with NEC(India) 2011, Busbar trunking system assembly conforming to IEC-614396-6 with KEMA-KEUR and ASTA Diamond certification, rated insulation voltage 1000 volts,rated impulse withsand voltage 8 KV, rated short circuit withstand capacity not less than 65 KA for 1 Sec, housing enclosure made of 1.5 mm thick GI sheet , epoxy polyster powder coated to atleast 60 microns, with high resistance to chemical agents, rigid and robust, compact and corrosion less; Busbar trunking system enclosure shall be designed for very high mechanical, electrical and heat loss efficiency; Enclosure shall be with IP-65 protection for outdoor suitable for power distribution and enclosure certified for a min of 1500 hr salt spray test as per IEC,
60
-
-
... More
horizontal or verticallly aqay direcction with span lengths jointed at regular intervals through removable block joints having all joint contact surfaces silver plated, together with all kinds of bends, tees etc with halogen free sandwitch insulation system of Class 130 with provison for termination inside power control centers of capacity for various types of loads, the busbar trunking system routed on rigid ladder type trays of appropriate span and adequate strength with support structures anchored to ground and also provided with GI canopy not less than 2mm thick complete all as per NEC : SP-30 : 2011, IS-8623, IEC-61439-6, IEC-60364-5-54, IEC-529 & latest relevant standards, all as specified and directed. ( From 3 MVA T/F to Main LT Panel No -1 & From 2.5 MVA T/F to Main LT Panel No -1 )
-
-
-
... More
Notes: 1. Compact Busbar trunking system shall be fixed to top of gallery/ roof/ floor/ duct/ trench/ walls with necessary micro concreting along with fasteners, fixing arrangements; connections at end points shall be done using copper flexibles.
2. The entire length of Busbar trunking system conductors including junction contacts shall be suitably insulated to withstand 150°C; The entire Busbar trunking system along with junction Monoblock shall be of IP-65 protection.
3. All the existing cables shall be removed only after energizing the bus duct and transformer; Installation shall be carried out in spaces with live cables and pipe lines around using required safety standards. 4. Supportitng structure for busbar trunking sytem between Transformer and user end panel included in the quoted rate. 5. Contactor shall be visit the site before submission of tender. 6. Cost of fixing clamps, tin plated copper flexibles and terminal links and Expansion joints etc are deemed to be included in quoted rate.
-
-
-
... More
S&F Compact Low Tension Aluminium Sandwich type Busbar trunking system 2500A, 433V Sandwich type 3 Phase +100% Neutral and equipped with integral protective earth conductor of aluminium alloy with cross section not less than 50% of phase conductor in accordance with NEC(India) 2011, Busbar trunking system assembly conforming to IEC-614396-6 with KEMA-KEUR and ASTA Diamond certification, rated insulation voltage 1000 volts,rated impulse withsand voltage 8 KV, rated short circuit withstand capacity not less than 65 KA for 1 Sec, housing enclosure made of 1.5 mm thick GI sheet , epoxy polyster powder coated to atleast 60 microns, with high resistance to chemical agents, rigid and robust, compact and corrosion less; Busbar trunking system enclosure shall be designed for very high mechanical, electrical and heat loss efficiency; Enclosure shall be with IP-65 protection for outdoor suitable for power distribution and enclosure certified for a min of 1500 hr salt spray test as per IEC,
30
-
-
... More
horizontal or verticallly aqay direcction with span lengths jointed at regular intervals through removable block joints having all joint contact surfaces silver plated, together with all kinds of bends, tees etc with halogen free sandwitch insulation system of Class 130 with provison for termination inside power control centers of capacity for various types of loads, the busbar trunking system routed on rigid ladder type trays of appropriate span and adequate strength with support structures anchored to ground and also provided with GI canopy not less than 2mm thick complete all as per NEC : SP-30 : 2011, IS-8623, IEC-61439-6, IEC-60364-5-54, IEC-529 & latest relevant standards, all as specified and directed. ( Qty - 30 RM) (From Main LT Panel No -2 to Sub LT Panel No -1)
Make: LEGRAND /GE /SCHNEIDER
-
-
-
... More
Notes: 1. Compact Busbar trunking system shall be fixed to top of gallery/ roof/ floor/ duct/ trench/ walls with necessary micro concreting along with fasteners, fixing arrangements; connections at end points shall be done using copper flexibles.
2. The entire length of Busbar trunking system conductors including junction contacts shall be suitably insulated to withstand 150°C; The entire Busbar trunking system along with junction Monoblock shall be of IP-65 protection.
3. All the existing cables shall be removed only after energizing the bus duct and transformer; Installation shall be carried out in spaces with live cables and pipe lines around using required safety standards. 4. Supportitng structure for busbar trunking sytem between Transformer and user end panel included in the quoted rate. 5. Contactor shall be visit the site before submission of tender. 6. Cost of fixing clamps, tin plated copper flexibles and terminal links and Expansion joints etc are deemed to be included in quoted rate.
-
-
-
... More
S&F of Compact Low Tension Aluminium Sandwich type Busbar trunking system 2000A, 433V Sandwich type 3 Phase +100% Neutral and equipped with integral protective earth conductor of aluminium alloy with cross section not less than 50% of phase conductor in accordance with NEC(India) 2011, Busbar trunking system assembly conforming to IEC-614396-6 with KEMA-KEUR and ASTA Diamond certification, rated insulation voltage 1000 volts,rated impulse withsand voltage 8 KV, rated short circuit withstand capacity not less than 65 KA for 1 Sec, housing enclosure made of 1.5 mm thick GI sheet , epoxy polyster powder coated to atleast 60 microns, with high resistance to chemical agents, rigid and robust, compact and corrosion less; Busbar trunking system enclosure shall be designed for very high mechanical, electrical and heat loss efficiency; Enclosure shall be with IP-65 protection for outdoor suitable for power distribution and enclosure certified for a min of 1500 hr salt spray test as per IEC,
30
-
-
... More
horizontal or verticallly aqay direcction with span lengths jointed at regular intervals through removable block joints having all joint contact surfaces silver plated, together with all kinds of bends, tees etc with halogen free sandwitch insulation system of Class 130 with provison for termination inside power control centers of capacity for various types of loads, the busbar trunking system routed on rigid ladder type trays of appropriate span and adequate strength with support structures anchored to ground and also provided with GI canopy not less than 2mm thick complete all as per NEC : SP-30 : 2011, IS-8623, IEC-61439-6, IEC-60364-5-54, IEC-529 & latest relevant standards, all as specified and directed. ( Qty - 30 RM) (From Main LT Panel No -2 to Sub LT Panel No -2)
-
-
-
... More
Notes: 1. Compact Busbar trunking system shall be fixed to top of gallery/ roof/ floor/ duct/ trench/ walls with necessary micro concreting along with fasteners, fixing arrangements; connections at end points shall be done using copper flexibles.
2. The entire length of Busbar trunking system conductors including junction contacts shall be suitably insulated to withstand 150°C; The entire Busbar trunking system along with junction Monoblock shall be of IP-65 protection.
3. All the existing cables shall be removed only after energizing the bus duct and transformer; Installation shall be carried out in spaces with live cables and pipe lines around using required safety standards. 4. Supportitng structure for busbar trunking sytem between Transformer and user end panel included in the quoted rate. 5. Contactor shall be visit the site before submission of tender. 6. Cost of fixing clamps, tin plated copper flexibles and terminal links and Expansion joints etc are deemed to be included in quoted rate.
-
-
-
... More
Supply, Install, testing and commissioning, factory made and type tested (CPRI approved OEM) LT panel board outdoor type, weather, dust and vermin proof, free standing floor mounting type mounted on foundation, separate cable alley or BBT for all the feeders, suitable for 440Volts, 3 Phase 4 wire 50Hz AC supply system, conforming to IS, IP-65 class protection and made of 3 mm CRCA sheet & angle iron frame, compartmentalized with rubber gasket hinged doors, front & rear opening and locking arrangement (including provision of 65mm Godrej (freedom) lock with 2 keys) with necessary bus bar arrangement with electrolytic grade aluminium bus bar of 5000 Amps @0.8A/Sqmm rating for phase and neutral 4 strips with colour coded PVC sleeves, installed on epoxy insulators housed in separate bus chambers covered with heat shrinkable sleeves with necessary bus bar tapings for ACB/MCCBs, Digital MFM meter class 1, 5000/5 A CT coils 15 VA class 1,TNC switch, on off & emergency push buttons with sector switch,
1
-
-
... More
copper control wiring of required size for instruments and duly powder coated on the outside and inside including air ventilation for heat dissipation, suitable size knock out holes for cable glands, cable gland and lugs for incoming and outgoing cable etc., independent multilayer chambers to accommodate complete with necessary foundation complete all as specified & directed including the following accessories :-
(a) Aluminium Bus bar suitable capacity TPN, full for phase and neutral with colour code PVC sleeves. - 01 Job
(b) LED RYB, ON, OFF & TRIP indication lamps – 01 set (c) LED Ammeter and voltmeter witn necessary CTs and display of required rating .
(d) ACB 5000 Amps,100 KA 4 POLE, 415 Volts ( with over load , short circuit, earth fault protection including UV & Shunt releases)- 01Nos (As Incomer)
(e) ACB 1600 Amps,50 KA 4 POLE, 415 Volts ( with over load , short circuit, earth fault protection including UV & Shunt releases)- 01Nos (As Out going)
(f) ACB 1000 Amps,50 KA 4 POLE, 415 Volts ( with over load , short circuit, earth fault protection including UV & Shunt releases)- 01Nos (As Out going)
(g) ACB 800 Amps,50 KA 4 POLE, 415 Volts ( with over load , short circuit, earth fault protection including UV & Shunt releases)- 01Nos (As Out going)
-
-
-
... More
Supply, Install, testing and commissioning, factory made and type tested (CPRI approved OEM) LT panel board outdoor type, weather, dust and vermin proof, free standing floor mounting type mounted on foundation, separate cable alley or BBT for all the feeders, suitable for 440Volts, 3 Phase 4 wire 50Hz AC supply system, conforming to IS, IP-65 class protection and made of 3 mm CRCA sheet & angle iron frame, compartmentalized with rubber gasket hinged doors, front & rear opening and locking arrangement (including provision of 65mm Godrej (freedom) lock with 2 keys) with necessary bus bar arrangement with electrolytic grade aluminium bus bar of 5000 Amps @0.8A/Sqmm rating for phase and neutral 4 strips with colour coded sleeves, installed on epoxy insulators housed in separate bus chambers covered with heat shrinkable sleeves with necessary bus bar tapings for ACB/MCCBs, Digital MFM meter class 1, 5000/5 A CT coils 15 VA class 1,TNC switch, on off & emergency push buttons with sector switch,
1
-
-
... More
copper control wiring of required size for instruments and duly powder coated on the outside and inside including air ventilation for heat dissipation, suitable size knock out holes for cable glands, cable gland and lugs for incoming and outgoing cable etc., independent multilayer chambers to accommodate complete with necessary foundation complete all as specified and directed including the following accessories :-
(a) Aluminium Bus bar suitable capacity TPN, full for phase and neutral with colour code PVC sleeves. - 01 Job
(b) LED RYB, ON, OFF & TRIP indication lamps – 01 set (c) LED Ammeter and voltmeter witn necessary CTs and display of required rating .
(d) Micro processor based ACB 5000 Amps,100 KA 4 POLE, 415 Volts ( with over load , short circuit, earth fault protection including UV & Shunt releases)- 01Nos (As Incomer)
(e) Micro processor bAWS ACB 2500 Amps,50 KA 4 POLE, 415 Volts ( with over load , short circuit, earth fault protection including UV & Shunt releases)- 01Nos (As Out going)
(f) Micro processor based ACB 1600 Amps,50 KA 4 POLE, 415 Volts ( with over load , short circuit, earth fault protection including UV & Shunt releases)- 01Nos (As Out going)
-
-
-
... More
Supply, Install, testing and commissioning, factory made and type tested (CPRI approved OEM) LT panel board outdoor type, weather, dust and vermin proof, free standing floor mounting type mounted on foundation, separate cable alley or BBT for all the feeders, suitable for 440Volts, 3 Phase 4 wire 50Hz AC supply system, conforming to IS, IP-65 class protection and made of 3 mm CRCA sheet & angle iron frame, compartmentalized with rubber gasket hinged doors, front & rear opening and locking arrangement (including provision of 65mm Godrej (freedom) lock with 2 keys) with necessary bus bar arrangement with electrolytic grade aluminium bus bar of 3200 Amps @0.8A/Sqmm rating for phase and neutral 4 strips with colour coded sleeves, installed on epoxy insulators housed in separate bus chambers covered with heat shrinkable sleeves with necessary bus bar tapings for ACB/MCCBs, Digital MFM meter class 1, -/5 A CT coils 15 VA class 1,TNC switch, on off & emergency push buttons with sector switch,
1
-
-
... More
copper control wiring of required size for instruments and duly powder coated on the outside and inside including air ventilation for heat dissipation, suitable size knock out holes for cable glands, cable gland and lugs for incoming and outgoing cable etc., independent multilayer chambers to accommodate complete with necessary foundation complete all as specified and directed including the following accessories :-
(a) Aluminium Bus bar suitable capacity TPN, full for phase and neutral with colour code PVC sleeves. - 01 Job
(b) LED RYB, ON, OFF & TRIP indication lamps – 01 set (c) LED Ammeter and voltmeter witn necessary CTs and display of required rating .
(d) ACB 2500 Amps,50 KA 4 POLE, 415 Volts (with over load , short circuit, earth fault protection including UV & Shunt releases)- 01Nos (As Incomer)
(e) ACB 1000 Amps,50 KA 4 POLE, 415 Volts (with over load , short circuit, earth fault protection including UV & Shunt releases)- 02 Nos (As Out going)
(f) MCCB 400 Amps,50 KA 4 POLE, 415 Volts (with adj over load , short circuit protection)- 01Nos (As Out going)
(g) MCCB 250 Amps,36 KA 4 POLE, 415 Volts (with adj over load , short circuit protection)- 01Nos (As Out going)
(h) MCCB 63 Amps,25 KA 4 POLE, 415 Volts (with adj over load , short circuit protection)- 01Nos (As Out going)
-
-
-
... More
Supply, Install, testing and commissioning, factory made and type tested (CPRI approved OEM) LT panel board outdoor type, weather, dust and vermin proof, free standing floor mounting type mounted on foundation, separate cable alley or BBT for all the feeders, suitable for 440Volts, 3 Phase 4 wire 50Hz AC supply system, conforming to IS, IP-65 class protection and made of 3 mm CRCA sheet & angle iron frame, compartmentalized with rubber gasket hinged doors, front & rear opening and locking arrangement (including provision of 65mm Godrej (freedom) lock with 2 keys) with necessary bus bar arrangement with electrolytic grade aluminium bus bar of 2400 Amps @0.8A/Sqmm rating for phase and neutral 4 strips with colour coded sleeves, installed on epoxy insulators housed in separate bus chambers covered with heat shrinkable sleeves with necessary bus bar tapings for ACB/MCCBs, Digital MFM meter class 1, -/5 A CT coils 15 VA class 1,TNC switch, on off & emergency push buttons with sector switch,
1
-
-
... More
copper control wiring of required size for instruments and duly powder coated on the outside and inside including air ventilation for heat dissipation, suitable size knock out holes for cable glands, cable gland and lugs for incoming and outgoing cable etc., independent multilayer chambers to accommodate complete with necessary foundation complete all as specified and directed including the following accessories :- (a) Aluminium Bus bar suitable capacity TPN, full for phase and neutral with colour code PVC sleeves. - 01 Job
b) LED RYB, ON, OFF & TRIP indication lamps – 01 set c) LED Ammeter and voltmeter witn necessary CTs and display of required rating .
d) ACB 1600 Amps,50 KA 4 POLE, 415 Volts ( with over load , short circuit, earth fault protection including UV & Shunt releases)- 01Nos (As Incomer)
-
-
-
... More
e) ACB 1000 Amps,50 KA 4 POLE, 415 Volts ( with over load , short circuit, earth fault protection including UV & Shunt releases)- 01 Nos (As Out going)
f) MCCB 400 Amps,50 KA 4 POLE, 415 Volts ( with adj over load , short circuit protection)- 01Nos (As Out going)
g) MCCB 250 Amps,36 KA 4 POLE, 415 Volts ( with adj over load , short circuit protection)- 01Nos (As Out going)
h) MCCB 63 Amps,25 KA 4 POLE, 415 Volts ( with adj over load , short circuit protection)- 01Nos (As Out going)
i) Panel wiring with PVC Insulated un sheathed single core, 1100 Volts grade cable with copper conductor, multi stranded of suitable size. - 01 Job
j) Interconnection of busbar with MCCB, , contactor with suitable size aluminium strip - 01 Job
k) Provisioning of cable glands and cable lugs for all incoming and out going cables & connecting the earthing to an earthing test point to main switch board as specified and testing on completion complete all as specified & directed by Engr-in-Charge. - 1 Job
-
-
-
... More
Cutting of existing bituminious / PCC road or flooring / plinth protection for laying of GI pipe in road intersection for passing of HT XLPE cable including excavation in any type of soil, returning and filling in and making good top 30cm of the trench by providing PCC 1:2:4 type B1 using 20mm graded stone aggregate to flush with existing road surface complete all as specified and directed.
820
-
-
... More
Supply and laying in trenches,Control cable 1100 volts with PVC insulated and steel armoured with multi stranded copper conductor of the following sizes: -
-
-
-
... More
(a) 4 core 1.5 sqmm
70
-
-
... More
(b) 12 core 1.5 sqmm
60
-
-
... More
(c) 6 core 1.5 sqmm
40
-
-
... More
(d) 2 core 1.5 sqmm
30
-
-
... More
(e) 3 core 1.5 sqmm
Note for item No 23
(i) Control cabling shall be executed and certified through a licenced agency as per IE Rules.
(ii) Submit the single line diagram of control wiring for transformers, SF6 circuit breaker and CRP panel.
15
-
-
... More
Design, Supply, Testing, Installation & Commissioning of 1000 KVAR LT APFC Panel for 2.5 MVA Transformer with 2500A ACB as Incomer, 3 Ph.,440 V, 14 Step APFC Panel with 7% Cu. Wound Detuned Harmonic Filter Reactor, Cu. Bus Bars, AC3 Duty Power Contactors, L & T Make, Heavy Duty, LTBCU Box type Capacitors, L&T Make Switchgears, metering and Equipment’s include necessary foundation complete all as specified and directed. Panel Dimensions : L : 6000 mm, W : 1000 mm, H : 1975 mm
1
-
-
... More
Design, Supply, Testing, Installation & Commissioning of 1200 KVAR LT APFC Panel for 3 MVA Transformer with 2500A ACB as Incomer, 3 Ph., 440 V 16 Step APFC Panel with 7% Cu. Wound Detuned Harmonic Filter Reactor, Cu. Bus Bars, AC3 Duty Power Contactors, L & T Make, Heavy Duty, LTBCU Box type Capacitors, L&T Make Switchgears, metering and Equipment’s include necessary foundation complete all as specified and directed.Panel Dimensions : L : 6600 mm, W : 1000 mm, H : 1975 mm
1
-
-
... More
SEWAGE DISPOSAL
Supply and laying on site LLDPE septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, vent shaft, connection with upflow filter including media for 30 users capacity complete all as specified and directed.
1
-
-
... More
Soakage well excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonary with top ring of M-25 concrete including intercepting chamber and screen chamber made of brick masonry in CM, RCC cover slab in M-25/SFRC cover, interconnection pipes RCC/DWC complete filled with brick bats of size 2.4 M dia X 3.0 M effective depth complete all as specified and directed.
2
-
-
... More
AREA DRAINAGE
Extra for forming fair finished to drain or channel 60 to 90cm inner girth in cement concrete using extra cement including forms, moulds etc complete all as specified and directed.
35
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%