Military Engineer Services Tender

... More
The MES has issued a formal invitation for competitive bids for the Military Engineer Services project, for Certain Repairs To Sewage System, Drains, Manholes, Septic Tanks And Misc Works Under Age B/r-i At Dlrl Lab And Asl Lab Under Age B/r-i, Hyderabad in Hyderabad, Telangana, with an estimated contract value of Rs. 49,00,000. The bid opening date for this tender is 22-05-2025 and the last date for bid submission is 18-06-2025. Interested bidders for Military Engineer Services tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.

Military Engineer Services - MES Tender

Works
Civil And Construction
Drainage Work
Eprocure
Opening Date22 May 2025
Closing Soon18 Jun 2025
Tender Amount₹ 49,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Cleaning of septic tank of 50 to 100 users by removing sludge/waste material (night soil) inside the manhole, washing with water and disposing off sludge/waste material from site in a hygienic manner complete all as directed.

20

-

-

... More
Cleaning of septic tank of 200 to 1000 users by removing sludge/waste material (night soil) inside the manhole, washing with water and disposing off sludge/waste material from site in a hygienic manner complete all as directed.

10

-

-

... More
Mechanically pumping out sewage water from Septic tanks/sump well where required and as directed with taking precautionary measurers including tools & plants as required and removing to place out side MOD land from the site complete(working in foul condition) complete all as specified and as directed.

300

-

-

... More
Removing of soaked material from the existing soakage pits of any size and from any depth in foul condition and supplying & filling, spreading broken brick bats of gauge 80mm to 150mm in 25cm thick layers complete all as directed.

20

-

-

... More
Cleaning and removing all scale and dirt etc from sevice water tanks of capacity exceeding 500 ltrs and not exceeding 1000 ltrs and from mouths of circulating pipes,Date of cleaning to be written in synthetic enamel paint on all tank, after cleaning, size of letters shall be 50mm in height and text shall be “TANK CLEANED ON DD/MM/YYYY etc complete all as directed.

40

-

-

... More
Cleaning and removing all scale and dirt etc from sevice water tank of capacity exceeding 1000 ltrs but not exceeding 2000 ltrs and from mouths of circulating pipes,Date of cleaning to be written in synthetic enamel paint on all tank, after cleaning, size of letters shall be 50mm in height and text shall be “TANK CLEANED ON DD/MM/YYYY etc complete all as directed.

30

-

-

... More
Cleaning surfaces of RCC and AC sheet roofing RCC chajjah , sides of parapet walls by uprooting the unwanted vegetation and scrapping with steel wire brush ,watering and sweeping including taking down the leonine trees over roofs and removing the derbis to a distance exc 250m and n.exc.,500m complete all as directed.

10000

-

-

... More
Excavation in trenches, in soft/loose soil, not exceeding 1.5 m wide and not exceeding 1.5 m in depth, for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out complete all as directed.

108

-

-

... More
M&L for 150mm bore Reinforced concrete pipes, class NP2, laid and jointed complete with collars including taking out existing old existing pipe complete all as directed

200

-

-

... More
Material and labour for reinforced cement concrete pipes, 200mm bore, class NP2, laid and jointed complete with collars including taking out existing old existing pipe complete all as directed.

100

-

-

... More
M&L for cement concrete bed 1:3:6 type C2 to drain pipe 150 mm bore including packing under and hunching against the sides of pipes after they laid and tested including demolition of old concrete and removing debris outside of MOD land complete all as directed.

200

-

-

... More
M&L for cement concrete bed 1:3:6 type C2 to drain pipe 150 mm bore including packing under and hunching against the sides of pipes after they laid and tested including demolition of old concrete and removing debris outside of MOD land complete all as directed.

100

-

-

... More
Returning, filling in, including spreading leveling watering and well ramming in layers not exceeding 25cm thick using soil complete all as directed.

280

-

-

... More
Removing excavated material to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as directed.

20

-

-

... More
Cleaning of Gully traps of any size and any depth by removing the material (sludge materials) and placing back the cover in position complete all as directed.

200

-

-

... More
Clearing the urinal blockage of any length and dia by Roding and removing the materials (sludge) to distance not exceeding 50m all as directed.

150

-

-

... More
Clearing WC blockages up to 1st manholes any length and dia by Roding and removing the materials (sludge) to a distance not exceeding 50m complete all as directed.

150

-

-

... More
Note: For (Sl Item No. 17 to 19) (a) The contractor shall deploy safaiwala alongwith T&P to attend the complaints. The supervisor will report to JE (Civil) in complaint cell/ service centre of AGE B/R-I under GE (I) R&D Kanchanbagh located in DLRL and ASL area daily between 0830 to 0900hrs (except on Sunday/Gazetted holidays). (b) The complaints shall be attended preferably on the same day and complaints slips duly signed by the user will be deposited back with JE(Civil) on the same day. (c) Working time for all the people employed by the contractor will be from 0900 hrs to 1700 hrs In case of any emergency, they can be called at any time beyond specified time and will be given off at the discretion of Engr-in-Charge. (d) A penalty of Rs 200/- per day will be levied in case of absence of any of supervisor or safaiwala. (e) Manpower/ employees deployed by contractor shall have safety measures for the job and life insurance policy for compensation in case of any accident.

-

-

-

... More
M&L for precast cement concrete 1:2:4, type B1 (using 20 mm graded stone aggregate) manholes or cover slabs including necessary form work , including demolition of existing reinforced cement concrete cover slabs complete all as directed.

10

-

-

... More
S&F mild steel TMT bars 6 mm to 8mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia., or securing with clips all as specified.

300

-

-

... More
M&L for walling of squared rubble, brought upto courses, built in CM 1:4 including demolition of existing old stone masonry complete all as specified and directed.

40

-

-

... More
M&L raised pointing in CM 1:4 to square, random or polygonal rubble, uncoursed or brought up to courses complete all as specified and directed.

20

-

-

... More
M&L for broken glass coping on top of walls in CM 1:3 complete all as specified and directed.

20

-

-

... More
M&L for PCC (1:2:4) B1 type (20mm graded aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs complete all as specified and directed.

2

-

-

... More
M&L for walling of squared rubble, brought upto courses, built in CM (1:4) reusing old stones, including demolition of existing old stone masonry complete all as specified and directed.

40

-

-

... More
M & L for Brick work with sub class 'B' bricks, straight or curved on plan exceeding 6 m mean radius, built in CM (1:4) including demolition of existing old brick masonry complete all as directed.

10

-

-

... More
Taking down cement plaster of any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc.complete all as specified.

600

-

-

... More
Material and labour 10mm thick rendering on other than faces of brick work or concrete surface in CM (1:6) to be finished even and smooth without using extra cement complete all as specified and directed.

400

-

-

... More
M&L for rendering 15mm thick in CM (1:4) on fair faces of brick or concrete surfaces and finished even and smooth without using extra cement complete all as directed.

200

-

-

... More
M & L for preparation of new plastered surfaces of wall applying two coats of oil bound distemper over primer and wall care putty complete all as directed.

400

-

-

... More
M & L for Preparation of new plastered surfaces and applying two coats of weather proof antifungal Acrylic Exterior emulsion paint of Apex Ultima and shade over a coat of approved primer as recommended by the manufacturer over a coat of putty to make surfaces smooth all as required and as directed.

200

-

-

... More
M & L for preparation and complete removal of existing treatment of old plastered surfaces of wall and applying two coats of oil bound distemper complete all as directed.

500

-

-

... More
M & L for preparation and complete removal of existing treatment of old plastered surfaces of wall and applying two coats of oil bound distemper over primer and wall care putty complete all as directed.

600

-

-

... More
M & L for complete removal of existing treatement and and applying two coats of weather proof Acrylic Exterior emulsion paint of Apex Ultima and shade over a coat of approved primer as recommended by the manufacturer over a coat of putty to make surfaces smooth all as required and as directed.

600

-

-

... More
M&L for preparation of old painted steel/iron surafces of any description, not otherwise descri-bed, over 10cm width or girth and applying one coat of synthetic enamel paint complete all as directed

150

-

-

... More
M&L Non-skid coloured matt finish ceramic tiles 7 to 8 mm thick (square /rectangular ) area of each tile exceeding 0.11 sqm but not exc 0.18 sqm in floor etc . set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over a screed bed 20 mm thick in CM 1:6 incl dismantling old tiles complete all as specified and directed.

85

-

-

... More
M&L Glazed ceramic coloured tiles as in vertical surfaces 450x300x7 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10 mm th backing coat of cement mortar (1:4) including dismantling old tiles all as specified and directed.

120

-

-

... More
M&L machine pressed chequered cement concrete tiles 30cm x 30cm x20 mm thick with grey cement and pigment set jointed and pointed in neat cement slurry in floors laid over 20mm thick screed or bedding layer in CM (1:6), including dismantling existing floor tile of any descrption complete all as directed.

50

-

-

... More
M&L for 20mm thick polished granite stone (of any type) work (table rubbed and polished) in steps, jambs,dados, pillars, window cills, cooking platforms and like etc. including making suitable holes for tucking in oval shape WHB in the granite slab including cutting grooves and nosing, tin oxide polish to top and edges, 15mm thick screed bed in CM (1:4) bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including taking down old granite stone along with screed bed complete all as directed.

30

-

-

... More
S&F PVC (SWR) pipes,150 bore of pipe, single socketed, in any length with rubber ring joints, fixed as in rain water pipes /spouts etc including making necessary holes in walls or parapet and making good with cement mortar (1:4) and taking down old rain water pipe of any description and in any position complete all as specified and directed.

50

-

-

... More
S&F in repairs 150mm PVC (SWR) bends any radius complete all as directed

15

-

-

... More
M&L for rotational moulded triple layered polythene water storage tank (cylindrical vertical with threaded lid) hoisted and fixed in position all as specified in SSR part I capacity of tank 500 ltrs including dismantling existing damaged PVC tank complete all as directed.

10

-

-

... More
M&L for rotational moulded triple layered polythene water storage tank (cylindrical vertical with threaded lid) hoisted and fixed in position all as specified in SSR part I capacity of tank 1000 ltrs including dismantling existing damaged PVC tank complete all as directed.

10

-

-

... More
S&F in repairs ball brass valves of 20 mm dia, high pressure, with polyethylene float and fly nut complete, screwed for iron pipe or brass ferrule complete all as directed.

10

-

-

... More
S & F in repairs ball brass valves of 25 mm dia, high pressure, with polyethylene float and fly nut complete, screwed for iron pipe or brass ferrule complete all as directed.

10

-

-

... More
S & F in repairs 20 mm dia gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe complete all as directed.

10

-

-

... More
S & F in repairs 25 mm dia gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe complete all as directed.

10

-

-

... More
Taking up or down steel tubing and connections and supply and fixing 15mm dia GI tubing, medium grade with all fittings and fixed complete to walls and ceiling or laid in floors complete all as directed.

100

-

-

... More
Taking up or down steel tubing and connections and supply and fixing 20mm dia GI tubing, medium grade with all fittings and fixed complete to walls and ceiling or laid in floors complete all as directed.

100

-

-

... More
Taking up or down steel tubing and connections and supply and fixing 25mm dia GI tubing, medium grade with all fittings and fixed complete to walls and ceiling or laid in floors complete all as directed.

100

-

-

... More
S&F in repairs Urinal sensor complete all as directed. Make:- Hindware cat No 6007 or equivalent.

10

-

-

... More
S&F in repairs venetian blinds (vertical type) of 100mm wide straps with all fittings (to be matched with existing pattern) complete all as directed.

100

-

-

... More
S&F in repairs Multicolor double layered black out fabric roller zebra blinds horizontal type including hanging mechanism water resistant, UV protection for window etc fixed complete all as directed.

100

-

-

... More
S&F vitrified tiles 10mm thick light shade (Square/ rectangular) polished area of each tile not exceeding 0.36 sqm in flooring set and jointed in neat cement slurry and pointed in coloured cement to match with existing floor over and including 20mm thick screed bed in cement mortar (1:6), including dismantling of old floor tile along with screed bed complete all as directed.

150

-

-

... More
All as per ser item No. 55 here-in-before but on vertical surfaces such as skirting over 10mm thick backing coat in CM (1:4) on fair faces of brick/concrete surfaces including dismantling old wall tiles along with backing coat complete all as directed.

30

-

-

... More
M&L for cement concrete (1:3:6), type C-1 (using 20mm graded crushed stone aggregate) as in surface channel / drain including demolition of existing cement concrete in drains complete all as specified and directed.

2

-

-

... More
M&L Extra for forming fair finished drain channel 30cm inner girth in cement concrete using extra cement including forms / mould, mitred / stopped ends etc complete all as specified and directed.

100

-

-

... More
Hacking out old broken glass (any thickness, size, quality or description) from wood/steel frame including punching or drilling out old glazing pins/spring clips and supply and fixing 5.50 mm thick plain sheet glass and glazing with oil putty in squares exc 0.50 Sqm in each pane complete all as directed.

36

-

-

... More
M&L for MS framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165de E-165 complete all as specified.

405

-

-

... More
M&L Preparation of new steel and iron surfaces of any description not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.

60

-

-

... More
S&F in repairs vitreous china urinal partition white of size 310x700mm with securing with clips all as specified.

10

-

-

... More
S&F in repairs frosted glass urinal partition white of size 310x700mm with securing with clips all as specified.

10

-

-

... More
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/loose soil.

120

-

-

... More
M&L for hardcore of gauge n exc. 63 mm of broken stone boulders, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface.

12

-

-

... More
M&L for PCC 1:4:8 type D2 (using 40mm graded stone agg) 75mm thick as in floor sub base etc as specified.

120

-

-

... More
M&L for pressed precast concrete interlocking paver block any shape and size conforming to IS 155658 - 2006 of 60 mm thickness M-35 grade with grey cement and pigment including laid over 50mm thick sand cushion bed and preparing the surface to uniform level to recieve tiles complete all as specified and directed by Engr in-Charge.

120

-

-

... More
M & L for providing cement concrete PCC (1:2:4) type B-1 mix using 20 mm graded stone aggregate as in sides coping etc complete.

5

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.