The MES has issued a formal invitation for competitive bids for the Military Engineer Services project, for Special Repairs / Replacement To Lt Oh / Ug Cables Including Connected Works At Certain Locations At Afa Hyderabad in Medchal Malkajgiri, Telangana, with an estimated contract value of Rs. 1,31,50,000. The bid opening date for this tender is 30-10-2026 and the last date for bid submission is 20-11-2026. Interested bidders for Military Engineer Services tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.

Military Engineer Services - MES Tender - Telangana Tender

Opening Date30 Oct 2026
Closing Soon20 Nov 2026
Tender Amount₹ 1,31,50,000 
Notes
Download

Costs

Description

Special Repairs / Replacement To Lt Oh / Ug Cables Including Connected Works At Certain Locations At Afa Hyderabad

Contact

Unlock the Tender details

GEM & Bid Advisory Services

Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

Unlock the Tender details
... More
Supply and laying in trenches/through pipes or bare in road crossings/ paths /drains /ducts /floors /along poles/ walls/ ceilings/ equipments etc. Cable Under ground, armoured, XLPE insulated with stranded aluminium conductor, 1100 Volts grade of cross sectional area, 3.5 Core 400 Sqmm incl connecting with suitable glands, lugs etc complete all as specified and as directed. Make: Havells/Finolex/Polycab/Gloster

1350

4

-

... More
Description all as per Item No-04 above -ditto- but of cross sectional area, 3.5 Core 300 Sqmm.

560

5

-

... More
Description all as per Item No-04 above -ditto- but of cross sectional area, 3.5 Core 240 Sqmm.

570

6

-

... More
Description all as per Item No-04 above -ditto- but of cross sectional area, 3.5 Core 120 Sqmm.

480

7

-

... More
Description all as per Item No-04 above -ditto- but of cross sectional area, 3.5 Core 95 Sqmm.

740

8

-

... More
Description all as per Item No-04 above -ditto- but of cross sectional area, 3.5 Core 70 Sqmm.

930

9

-

... More
Description all as per Item No-04 above -ditto- but of cross sectional area, 3.5 Core 50 Sqmm.

170

10

-

... More
Description all as per Item No-04 above -ditto- but of cross sectional area, 4.0 Core 25 Sqmm.

4980

11

-

... More
Description all as per Item No-04 above -ditto- but of cross sectional area, 4.0 Core 16 Sqmm.

90

12

-

... More
Description all as per Item No-04 above -ditto- but of cross sectional area, 3.0 Core 16 Sqmm.

380

13

-

... More
IMPORTANT NOTES for Item Nos 4 to 13 : 1) Quoted rate is deemd to be inclusive of fixing/placing of Cable Route Indicator of type/size as appoved by the Engr-In-Charge at an interval of not more than 50.0 meters & at each & every bend or corner with engraved marking e.g. " MES LT CABLE 400 SQMM 3.5 CORE " in bold letters during refilling of the trench complete all as specified & as directed by the Engr-In-Charge. 2) Quoted rate is also deemed to be inclusive of Supply, Fixing & Testing of Outdoor type Joint / Bus-Bar Boxes made out of 3.15 mm thick CRCA sheet powder coated spray painted with & including of 04 x Aluminium bus-bars of 200 A rating each duly mounted on epoxy / porcelain insulators for jointing / connection of LT UG Cable incl PCC foundation, plinth / platform complete all as specified & as directed by the Engr-In-Charge.

-

-

-

... More
M&L for cutting the existing hardstanding/PCC/WBM road/rocky surfaces at a depth of not less than 75 cm & 30 cm in width for passing of LT cables through GI/DWC pipes, returning filling in, complete incl finishing the surfaces by providing cement concrete type B1 (1:2:4) with 20 mm graded aggregate upto 20 cm, finishing to a uniform smooth surface complete all as specified and as directed.

50

15

-

... More
Excavation in trenches by mechanical or other means n.exc 1.5m wide and n.exc 1.5m in depth for laying of pipe and getting out in hard dense soil complete all as specified and as directed.

1845

16

-

... More
NOTE for Item No 14 & 15 : 1) The requirement of JCB (if any) for cutting the hard standing/PCC/WBM road surface or during earthwork is deemed to be included in the unit quoted rates. 2) If any damage to any Cable of Air Force/BSNL/MES etc. or to any Pipe lines develops/occurs during execution of the works then the same shall be made good by the Contr to the entire satisfaction of the concerned Dept/Section & the costs of the same is deemed to be included in the unit quoted rates. 3) Quoted rate is also deemed to be inclusive of clearing/removing/cutting of vegetation/tree branches/small to medium plantings/bushes etc. so as to facilitate successful completion of the work. No extra/addl payment shall be allowed to the Contr in this regard. 4) The contractor/firm is required to visit the site prior to quoting of the subject items / work so as to ascertain the actual ground requirements. Any further query at a later date shall not be entertained & responsibility of the same shall rest on the contractor/ firm.

-

-

-

... More
Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete all as specified and as directed.

1661

18

-

... More
Removing of excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed.

184

19

-

... More
M&L for HDPE DWC (Double Wall Corrugated) Pipe of rating 450 N, ISI marked with Min OD 160 mm & Min ID 135 mm, Orange colour for LT UG Cable protection with & including Couplers with rubber rings & RR & NFP properties/features confirming to IS 16205 Part 24:2018 & IEC 61386 Part 24:2007 with & including necessary clamping on wall / other surfaces complete all as specified and as directed. Make :- Supreme (Cable Guard) / Astral (Telerex) or techno-commercially equivalent of Finolex / Polycab. NOTE : Purchase Vouchers & Test Certificates to be submitted in Original to the Engr-In-Charge.

2480

20

-

... More
M&L for HDPE DWC (Double Wall Corrugated) Pipe of rating 450 N, ISI marked with Min OD 120 mm & Min ID 100 mm, Orange colour for LT UG Cable protection with & including Couplers with rubber rings & RR & NFP properties/features confirming to IS 16205 Part 24:2018 & IEC 61386 Part 24:2007 with & including necessary clamping on wall / other surfaces complete all as specified and as directed. Make :- Supreme (Cable Guard) / Astral (Telerex) or techno-commercially equivalent of Finolex / Polycab. NOTE :- Purchase Vouchers & Test Certificates to be submitted in Original to the Engr-In-Charge.

1220

21

-

... More
M&L for HDPE DWC (Double Wall Corrugated) Pipe of rating 450 N, ISI marked with Min OD 75/77 mm & Min ID 63/59 mm, Orange colour for LT UG Cable protection with & including Couplers with rubber rings & RR & NFP properties/features confirming to IS 16205 Part 24:2018 & IEC 61386 Part 24:2007 with & including necessary clamping on wall / other surfaces complete all as specified and as directed. Make :- Supreme (Cable Guard) / Astral (Telerex) or techno-commercially equivalent of Finolex / Polycab. NOTE : Purchase Vouchers & Test Certificates to be submitted in Original to the Engr-In-Charge.

5895

22

-

... More
S&F danger notice plate of size 20 x 15 cm of 1.6mm thick mild-steel sheet, vitreous enamelled white, with letters, figures and conventioinal skull and bones in signal-red colour and fixed with MS clamps, bolts and nuts of approved size, for LT conforming to IS-2551 complete all as specified and as directed.

122

23

-

... More
M&L for earthing complete with Galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (in vertical position) earth pit not less than 2.25 mtr below normal ground level with the top edge of the earth plate not less than 1.5 mtr (B.G.L.) and connected to GI earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts, and washers of galvanized iron including PCC pit & cover with suitable handle, including necessary excavation and earth work in any type of soil, 20 mm dia med grade galvanized steel tube for watering with one end fixed with suitable funnel and wire mesh, 15 mm bore medium grade galvanized steel tubing for drawing earth lead GI strip protection & common salt, charcoal in alternate layers etc. complete all as shown in EP No 3 of SSR Part 1 and testing on completion incl taking down old unsv earthing assy complete all as specified and as directed.

103

24

-

... More
M&L for earthing complete with Galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (in vertical position) earth pit not less than 2.25 mtr below normal ground level with the top edge of the earth plate not less than 1.5 mtr (B.G.L.) and connected to GI earth strip 32 x 6 mm by means of bolts, nuts, check nuts, and washers of galvanized iron including PCC pit & cover with suitable handle, including necessary excavation and earth work in any type of soil, 20 mm dia med grade galvanized steel tube for watering with one end fixed with suitable funnel and wire mesh, 40 mm bore medium grade galvanized steel tubing for drawing earth lead GI strip protection & common salt, charcoal in alternate layers etc. complete all as shown in EP No 3 of SSR Part 1 and testing on completion incl taking down old unsv earthing assy complete all as specified and as directed.

28

25

-

... More
IMPORTANT NOTES FOR ITEM NOS 22 & 23 : 1) On completion of the complete work/job the Contr is to perform earth resistance tests for each earthing job in the presence of the Engr-In-Charge or his rep & submit test certificates duly signed & certified. If the test results are not satisfactory or not within the permissible limits of 1.0 Ohm then the job is to be redone without any extra cost to the Dept till the results are satisfactory. 2) Cost of GI wire and GI Protection Pipe upto 7.5 mtr length & welding/brazing work is deemed to be included in the unit quoted rates. 3) Cost of Wire Mesh, Funnel, Earthwork, PCC Chamber with Cover, Test Point etc. is deemed to be included in the unit quoted rates.

-

-

-

... More
M & L for laying earth continuity conductor or main earthing lead of 32x6 mm galvanised iron strip, fixed to wall on batten or recess or chasses or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc, as required complete all as specified and as directed.

84

27

-

... More
M & L for laying earth continuity conductor or main earthing lead of 4 mm dia galvanised iron wire, fixed to wall on batten or recess or chasses or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc, as required complete all as specified and as directed.

270

28

-

... More
M&L for GI pipe medium grade with all running fittings (ISI Marked), fixed on Security / Street light PCC / Steel poles etc. of bore 15 mm complete all as specified and as directed. Make : TATA/JINDAL/PRAKASH.

880

29

-

... More
M&L for GI pipe medium grade with all running fittings (ISI Marked), laid in trenches, under road or fixing on wall/pole/crossing drain/nallah etc. of bore 40 mm complete all as specified and as directed. Make : TATA/JINDAL/PRAKASH.

450

30

-

... More
M&L for GI pipe medium grade with all running fittings (ISI Marked), laid in trenches, under road or fixing on wall/pole/crossing drain/nallah etc. of bore 100 mm complete all as specified and as directed. Make : TATA/JINDAL/PRAKASH. Note for Item Nos 26 to 28 : Wherever GI Protection pipes are to be placed/fitted above earths surface, cost of necessary clamping/fixing arrangements to the entire satisfaction of Engr-In-Charge is deemed to be included in the unit quoted rates.

50

31

-

... More
Supply and fix energy saving high power LED Street Light of 60W made up of pressure die cast aluminum housing with embedded PC cover having top opening, seperate driver compartment with IP66 protection, IK-09, Power factor > 0.95, Colour Temperature > 5700 K, Luminous Efficacy >100 Lumens/Watt, CRI > 80, Surge Protection > 6 KV, THD < 10%, and making electric connections in flexible conduit with & incl GI Pipe bracket of appropriate dia & necessary fixing arrangements like clamps, nuts, bolts, washers etc. complete all as specified and as directed. Make : LUKER, Cat No : LSTE060S or techno-commercially equivalent in HAVELLS/BAJAJ/PHILIPS/JAGUAR

122

32

-

... More
S & F loop in-loop out junction box of internal dimension 140 x 140 x 95 mm or higher size made out of FRP sheet with weather proof canopy and locking screw comprising of 20 Amps rated 4 way connectors for 3 Phase and Neutral incoming/out going mounted in the box, fixing on RCC poles etc. with & including suitable sized Aluminium/MS clamps, cable glands, lugs, nuts, bolts etc. & fitted with 01 Nos MCB SP 10A, 10KA breaking capacity, C Series complete all as specified and as directed. Make of FRP Junction Box : Sintex/CAPE ELECTRIC/HENSEL or techno-commercially eqvt & Make of MCB SP : L&T/Legrand/ABB/SIEMENS.

122

33

-

... More
Imp Note for Item Nos 29 & 30: 1) Design/Drawing/Technical catalogue/specifications along with comparative Rate Analysis to be submitted to the Engr-In-Charge/GE for Make/Sample approval of items whereever equivalency of Item(s) is concerned other than specified Make/Model/Cat/Part Ref concerned before placing order to the Manufacturer/Supplier. 2) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates. 3) Cost of 15 mm dia GI Pipes incl necessary clamping as directed by the Engr-In-Charge shall be measured & paid separately under relevant items.

-

-

-

... More
M&L for preparation of old painted surfaces of PCC / Steel Poles & applying two coats of weather coat paint (for PCC Poles) & two coats of Aluminium Paint (for Steel Poles) of approved colour & grade incl writing of Pole Numbers & also painting of GI Pipe brackets & clamps with two coats of Aluminium Paint over a coat of red oxide primer complete all as specified and as directed. NOTE : Cost of use/hiring/rent including transportation of Aluminum Ladders/Scaffolding arrangements etc. required for successful execution of the complete work/Job is deemed to be included in the unit quoted rates. Quoted rate is also deemed to be inclusive of all safety precautions/measures to be taken by the contractor for labour employed at the site.

122

35

-

... More
Supply, install, commissioning & testing of LT control panel board "out-door type" of appropriate size / dimensions factory fabricated CPRI approved (type-tested) with suitable neoprene rubber gasket to make it completely dust & vermin proof & degree of protection not less than IP-55 & general construction confirming to IS-13947, double door, front & back openable. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation & tinned copper bus-bar wrapped with coloured PVC tape/sleeves of rating in conformity to the Incoming ACB/MCCB rating. The panel board shall be fabricated out of 3.15 mm thick (for outer portions) & 2.0 mm thick (for inner portions) CRCA sheet duly pre-treated & powder coated, supporting angle iron frame & MC channel base suitable for 3 Ph, 4 wire system 415/440 volts grade incl complete internal wiring with not less than 2.5 sqmm copper wire incl cable glands of suitable sizes incl suitable PCC (1:3:6) type C-2 foundation , necessary earthwork (if any) complete all as specified and as directed with & incl the following accessories : [ LT Panel - 01 ]

1

36

-

... More
BUS-BAR & INTERNAL CONNECTIONS : The bus-bars shall be made up of 04 Nos high grade Aluminium 600 A rated, duly insulated with 1100 V grade standard colour coded PVC sleeves & rigidly mounted on suitable sized "F" class insulators of non-hygroscopic, non-combustible, all internal connections from main bus-bars to switch gears etc. PROVISION FOR CABLE ENTRY : The provision for cable entry/exit shall be provided in the bottom for both incoming & out-going cables with the help of glands matching the existing LT cable sizes. INCOMING : (a) MCCB 4P (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting,suitable for isolation, having breaking capacity 36 KA & of rating 335 to 500 A - 01 Nos. Make : Cat No : DZ7F0500DXD1AOOOO of Make L&T or techno-commercially equivalent of LEGRAND/SIEMENS.

-

-

-

... More
OUTGOINGS : (a) MCCB 4P (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting,suitable for isolation, having breaking capacity 36 KA & of rating 268 to 400 A - 02 Nos (1W + 1S). Make : Cat No : DZ6F0400DXD1AOOOO of Make L&T or techno-commercially equivalent of LEGRAND/SIEMENS. (b) MCCB 4P (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting,suitable for isolation, having breaking capacity 25 KA & of rating 32 to 40 A - 02 Nos (1W + 1S). Make : Cat No : DZ0F0040CXC1AOOOO of Make L&T or techno-commercially equivalent of LEGRAND/SIEMENS. (c) MCB, TPN, 10KA, 415V, "C" curve, 06-32 A, ISI marked - 01 Nos. Make : L&T/ABB/SIEMENS

-

-

-

... More
INSTRUMENTATION SYSTEM : (a) Digital type Multi-Function meter with built in selector Switch & 03 Nos CTs matching with the I/C breaker, Accuracy Class - 1.0, 3 phase, Size 96 x 96 mm. Make : Cat No WL411010OOOO of make L&T or techno-commercially equivalent of ELMEASURE/SECURE. (b) Indicator lamp with integral circuit (230/240V) & cluster LED (Red, Orange, Blue) - 01 Set. (c) Danger notice plate of size 20 x 15 cm of 1.6mm thick mild-steel sheet, vitreous enamelled white, with letters, figures and conventioinal skul and bones in signal-red colour and fixed with MS clamps, bolts and nuts of approved size, for LT conforming to IS-2551 - 02 Nos (Front & Back).

-

-

-

... More
Supply, install, commissioning & testing of LT control panel board "out-door type" of appropriate size / dimensions factory fabricated CPRI approved (type-tested) with suitable neoprene rubber gasket to make it completely dust & vermin proof & degree of protection not less than IP-55 & general construction confirming to IS-13947, double door, front & back openable. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation & tinned copper bus-bar wrapped with coloured PVC tape/sleeves of rating in conformity to the Incoming ACB/MCCB rating. The panel board shall be fabricated out of 3.15 mm thick (for outer portions) & 2.0 mm thick (for inner portions) CRCA sheet duly pre-treated & powder coated, supporting angle iron frame & MC channel base suitable for 3 Ph, 4 wire system 415/440 volts grade incl complete internal wiring with not less than 2.5 sqmm copper wire incl cable glands of suitable sizes incl suitable PCC (1:3:6) type C-2 foundation , necessary earthwork (if any) complete all as specified and as directed with & incl the following accessories : [ LT Panel - 02 ]

1

40

-

... More
BUS-BAR & INTERNAL CONNECTIONS : The bus-bars shall be made up of 04 Nos high grade Aluminium 500 A rated, duly insulated with 1100 V grade standard colour coded PVC sleeves & rigidly mounted on suitable sized "F" class insulators of non-hygroscopic, non-combustible, all internal connections from main bus-bars to switch gears etc. PROVISION FOR CABLE ENTRY : The provision for cable entry/exit shall be provided in the bottom for both incoming & out-going cables with the help of glands matching the existing LT cable sizes. INCOMING : (a) MCCB 4P (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting,suitable for isolation, having breaking capacity 36 KA & of rating 268 to 400 A - 01 Nos. Make : Cat No : DZ6F0400DXD1AOOOO of Make L&T or techno-commercially equivalent of LEGRAND/SIEMENS.

-

-

-

... More
OUTGOINGS : (a) MCCB 4P (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting,suitable for isolation, having breaking capacity 25 KA & of rating 20 to 25 A - 03 Nos (2W + 1S). Make : Cat No : DZ0F0025CXC1AOOOO of Make L&T or techno-commercially equivalent of LEGRAND/SIEMENS. (b) MCCB 4P (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting,suitable for isolation, having breaking capacity 25 KA & of rating 26 to 32 A - 01 Nos. Make : Cat No : DZ0F0032CXC1AOOOO of Make L&T or techno-commercially equivalent of LEGRAND/SIEMENS. (c) MCCB 4P (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting,suitable for isolation, having breaking capacity 25 KA & of rating 32 to 40 A - 03 Nos (2W + 1S). Make : Cat No : DZ0F0040CXC1AOOOO of Make L&T or techno-commercially equivalent of LEGRAND/SIEMENS.

-

-

-

... More
(d) MCCB 4P (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting,suitable for isolation, having breaking capacity 25 KA & of rating 50 to 63 A - 01 Nos. Make : Cat No : DZ0F0040CXC1AOOOO of Make L&T or techno-commercially equivalent of LEGRAND/SIEMENS. (e) MCCB 4P (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting,suitable for isolation, having breaking capacity 25 KA & of rating 64 to 80 A - 02 Nos (1W + 1S). Make : Cat No : DZ0F0080CXC1AOOOO of Make L&T or techno-commercially equivalent of LEGRAND/SIEMENS. (f) MCCB 4P (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting,suitable for isolation, having breaking capacity 36 KA & of rating 108 to 160 A - 02 Nos (1W + 1S). Make : Cat No : DZ2F0160DXD1AOOOO of Make L&T or techno-commercially equivalent of LEGRAND/SIEMENS. (g) MCB, TPN, 10KA, 415V, "C" curve, 06-32 A, ISI marked - 01 Nos. Make : L&T/ABB/SIEMENS

-

-

-

... More
INSTRUMENTATION SYSTEM : (a) Digital type Multi-Function meter with built in selector Switch & 03 Nos CTs matching with the I/C breaker, Accuracy Class - 1.0, 3 phase, Size 96 x 96 mm. Make : Cat No WL411010OOOO of make L&T or techno-commercially equivalent of ELMEASURE/SECURE. (b) Indicator lamp with integral circuit (230/240V) & cluster LED (Red, Orange, Blue) - 01 Set. (c) Danger notice plate of size 20 x 15 cm of 1.6mm thick mild-steel sheet, vitreous enamelled white, with letters, figures and conventioinal skul and bones in signal-red colour and fixed with MS clamps, bolts and nuts of approved size, for LT conforming to IS-2551 - 02 Nos (Front & Back).

-

-

-

... More
Supply, install, commissioning & testing of LT control panel board "out-door type" of appropriate size / dimensions factory fabricated CPRI approved (type-tested) with suitable neoprene rubber gasket to make it completely dust & vermin proof & degree of protection not less than IP-55 & general construction confirming to IS-13947, double door, front & back openable. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation & tinned copper bus-bar wrapped with coloured PVC tape/sleeves of rating in conformity to the Incoming ACB/MCCB rating. The panel board shall be fabricated out of 3.15 mm thick (for outer portions) & 2.0 mm thick (for inner portions) CRCA sheet duly pre-treated & powder coated, supporting angle iron frame & MC channel base suitable for 3 Ph, 4 wire system 415/440 volts grade incl complete internal wiring with not less than 2.5 sqmm copper wire incl cable glands of suitable sizes incl suitable PCC (1:3:6) type C-2 foundation , necessary earthwork (if any) complete all as specified and as directed with & incl the following accessories : [ LT Panel - 03 ]

1

45

-

... More
BUS-BAR & INTERNAL CONNECTIONS : The bus-bars shall be made up of 04 Nos high grade Aluminium 100 A rated, duly insulated with 1100 V grade standard colour coded PVC sleeves & rigidly mounted on suitable sized "F" class insulators of non-hygroscopic, non-combustible, all internal connections from main bus-bars to switch gears etc. PROVISION FOR CABLE ENTRY : The provision for cable entry/exit shall be provided in the bottom for both incoming & out-going cables with the help of glands matching the existing LT cable sizes. INCOMING : (a) MCCB 4P (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting,suitable for isolation, having breaking capacity 25 KA & of rating 26 to 32 A - 01 Nos. Make : Cat No : DZ0F0032CXC1AOOOO of Make L&T or techno-commercially equivalent of LEGRAND/SIEMENS.

-

-

-

... More
OUTGOINGS : (a) MCCB 4P (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting,suitable for isolation, having breaking capacity 25 KA & of rating 20 to 25 A - 02 Nos (1W + 1S). Make : Cat No : DZ0F0025CXC1AOOOO of Make L&T or techno-commercially equivalent of LEGRAND/SIEMENS. (b) MCB, TPN, 10KA, 415V, "C" curve, 06-32 A, ISI marked - 01 Nos. Make : L&T/ABB/SIEMENS (c) MCB, SPN, 10KA, 230V, "C" curve, 06-32 A, ISI marked - 05 Nos (4W + 1S). Make : L&T/ABB/SIEMENS

-

-

-

... More
INSTRUMENTATION SYSTEM : (a) Digital type Multi-Function meter with built in selector Switch & 03 Nos CTs matching with the I/C breaker, Accuracy Class - 1.0, 3 phase, Size 96 x 96 mm. Make : Cat No WL411010OOOO of make L&T or techno-commercially equivalent of ELMEASURE/SECURE. (b) Indicator lamp with integral circuit (230/240V) & cluster LED (Red, Orange, Blue) - 01 Set. (c) Danger notice plate of size 20 x 15 cm of 1.6mm thick mild-steel sheet, vitreous enamelled white, with letters, figures and conventioinal skul and bones in signal-red colour and fixed with MS clamps, bolts and nuts of approved size, for LT conforming to IS-2551 - 02 Nos (Front & Back).

-

-

-

... More
Supply, install, commissioning & testing of LT control panel board "out-door type" of appropriate size / dimensions factory fabricated CPRI approved (type-tested) with suitable neoprene rubber gasket to make it completely dust & vermin proof & degree of protection not less than IP-55 & general construction confirming to IS-13947, double door, front & back openable. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation & tinned copper bus-bar wrapped with coloured PVC tape/sleeves of rating in conformity to the Incoming ACB/MCCB rating. The panel board shall be fabricated out of 3.15 mm thick (for outer portions) & 2.0 mm thick (for inner portions) CRCA sheet duly pre-treated & powder coated, supporting angle iron frame & MC channel base suitable for 3 Ph, 4 wire system 415/440 volts grade incl complete internal wiring with not less than 2.5 sqmm copper wire incl cable glands of suitable sizes incl suitable PCC (1:3:6) type C-2 foundation , necessary earthwork (if any) complete all as specified and as directed with & incl the following accessories : [ LT Panel - 04 & 05 ]

2

49

-

... More
BUS-BAR & INTERNAL CONNECTIONS : The bus-bars shall be made up of 04 Nos high grade Aluminium 100 A rated, duly insulated with 1100 V grade standard colour coded PVC sleeves & rigidly mounted on suitable sized "F" class insulators of non-hygroscopic, non-combustible, all internal connections from main bus-bars to switch gears etc. PROVISION FOR CABLE ENTRY : The provision for cable entry/exit shall be provided in the bottom for both incoming & out-going cables with the help of glands matching the existing LT cable sizes. INCOMING : (a) MCCB 4P (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting,suitable for isolation, having breaking capacity 25 KA & of rating 32 to 40 A - 01 Nos. Make : Cat No : DZ0F0040CXC1AOOOO of Make L&T or techno-commercially equivalent of LEGRAND/SIEMENS.

-

-

-

... More
OUTGOINGS : (a) MCB, TPN, 10KA, 415V, "C" curve, 06-32 A, ISI marked - 01 Nos. Make : L&T/ABB/SIEMENS (b) MCB, SPN, 10KA, 230V, "C" curve, 06-32 A, ISI marked - 09 Nos (7W + 2S). Make : L&T/ABB/SIEMENS INSTRUMENTATION SYSTEM : (a) Digital type Multi-Function meter with built in selector Switch & 03 Nos CTs matching with the I/C breaker, Accuracy Class - 1.0, 3 phase, Size 96 x 96 mm. Make : Cat No WL411010OOOO of make L&T or techno-commercially equivalent of ELMEASURE/SECURE. (b) Indicator lamp with integral circuit (230/240V) & cluster LED (Red, Orange, Blue) - 01 Set. (c) Danger notice plate of size 20 x 15 cm of 1.6mm thick mild-steel sheet, vitreous enamelled white, with letters, figures and conventioinal skul and bones in signal-red colour and fixed with MS clamps, bolts and nuts of approved size, for LT conforming to IS-2551 - 02 Nos (Front & Back).

-

-

-

... More
Supply, install, commissioning & testing of LT control panel board "out-door type" of appropriate size / dimensions factory fabricated CPRI approved (type-tested) with suitable neoprene rubber gasket to make it completely dust & vermin proof & degree of protection not less than IP-55 & general construction confirming to IS-13947, double door, front & back openable. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation & tinned copper bus-bar wrapped with coloured PVC tape/sleeves of rating in conformity to the Incoming ACB/MCCB rating. The panel board shall be fabricated out of 3.15 mm thick (for outer portions) & 2.0 mm thick (for inner portions) CRCA sheet duly pre-treated & powder coated, supporting angle iron frame & MC channel base suitable for 3 Ph, 4 wire system 415/440 volts grade incl complete internal wiring with not less than 2.5 sqmm copper wire incl cable glands of suitable sizes incl suitable PCC (1:3:6) type C-2 foundation , necessary earthwork (if any) complete all as specified and as directed with & incl the following accessories : [ LT Panel - 06 ]

1

52

-

... More
BUS-BAR & INTERNAL CONNECTIONS : The bus-bars shall be made up of 04 Nos high grade Aluminium 100 A rated, duly insulated with 1100 V grade standard colour coded PVC sleeves & rigidly mounted on suitable sized "F" class insulators of non-hygroscopic, non-combustible, all internal connections from main bus-bars to switch gears etc. PROVISION FOR CABLE ENTRY : The provision for cable entry/exit shall be provided in the bottom for both incoming & out-going cables with the help of glands matching the existing LT cable sizes. INCOMING : (a) MCCB 4P (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting,suitable for isolation, having breaking capacity 25 KA & of rating 50 to 63 A - 01 Nos. Make : Cat No : DZ0F0040CXC1AOOOO of Make L&T or techno-commercially equivalent of LEGRAND/SIEMENS.

-

-

-

... More
OUTGOINGS : (a) MCB, TPN, 10KA, 415V, "C" curve, 06-32 A, ISI marked - 01 Nos. Make : L&T/ABB/SIEMENS (b) MCB, SPN, 10KA, 230V, "C" curve, 06-32 A, ISI marked - 15 Nos (12W + 3S). Make : L&T/ABB/SIEMENS

-

-

-

... More
INSTRUMENTATION SYSTEM : (a) Digital type Multi-Function meter with built in selector Switch & 03 Nos CTs matching with the I/C breaker, Accuracy Class - 1.0, 3 phase, Size 96 x 96 mm. Make : Cat No WL411010OOOO of make L&T or techno-commercially equivalent of ELMEASURE/SECURE. (b) Indicator lamp with integral circuit (230/240V) & cluster LED (Red, Orange, Blue) - 01 Set. (c) Danger notice plate of size 20 x 15 cm of 1.6mm thick mild-steel sheet, vitreous enamelled white, with letters, figures and conventioinal skul and bones in signal-red colour and fixed with MS clamps, bolts and nuts of approved size, for LT conforming to IS-2551 - 02 Nos (Front & Back).

-

-

-

... More
Supply, install, commissioning & testing of LT control panel board "out-door type" of appropriate size / dimensions factory fabricated CPRI approved (type-tested) with suitable neoprene rubber gasket to make it completely dust & vermin proof & degree of protection not less than IP-55 & general construction confirming to IS-13947, double door, front & back openable. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation & tinned copper bus-bar wrapped with coloured PVC tape/sleeves of rating in conformity to the Incoming ACB/MCCB rating. The panel board shall be fabricated out of 3.15 mm thick (for outer portions) & 2.0 mm thick (for inner portions) CRCA sheet duly pre-treated & powder coated, supporting angle iron frame & MC channel base suitable for 3 Ph, 4 wire system 415/440 volts grade incl complete internal wiring with not less than 2.5 sqmm copper wire incl cable glands of suitable sizes incl suitable PCC (1:3:6) type C-2 foundation , necessary earthwork (if any) complete all as specified and as directed with & incl the following accessories : [ LT Panel - 07 ]

1

56

-

... More
BUS-BAR & INTERNAL CONNECTIONS : The bus-bars shall be made up of 04 Nos high grade Aluminium 200 A rated, duly insulated with 1100 V grade standard colour coded PVC sleeves & rigidly mounted on suitable sized "F" class insulators of non-hygroscopic, non-combustible, all internal connections from main bus-bars to switch gears etc. PROVISION FOR CABLE ENTRY : The provision for cable entry/exit shall be provided in the bottom for both incoming & out-going cables with the help of glands matching the existing LT cable sizes. INCOMING : (a) MCCB 4P (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting,suitable for isolation, having breaking capacity 36 KA & of rating 108 to 160 A - 01 Nos. Make : Cat No : DZ2F0160DXD1AOOOO of Make L&T or techno-commercially equivalent of LEGRAND/SIEMENS.

-

-

-

... More
OUTGOINGS : (a) MCCB 4P (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting,suitable for isolation, having breaking capacity 25 KA & of rating 13 to 16 A - 03 Nos (2W + 1S). Make : Cat No : DZ0F0016CXC1AOOOO of Make L&T or techno-commercially equivalent of LEGRAND/SIEMENS. (b) MCCB 4P (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting,suitable for isolation, having breaking capacity 25 KA & of rating 26 to 32 A - 08 Nos (6W + 2S). Make : Cat No : DZ0F0032CXC1AOOOO of Make L&T or techno-commercially equivalent of LEGRAND/SIEMENS. (c) MCB, TPN, 10KA, 415V, "C" curve, 06-32 A, ISI marked - 01 Nos. Make : L&T/ABB/SIEMENS

-

-

-

... More
INSTRUMENTATION SYSTEM : (a) Digital type Multi-Function meter with built in selector Switch & 03 Nos CTs matching with the I/C breaker, Accuracy Class - 1.0, 3 phase, Size 96 x 96 mm. Make : Cat No WL411010OOOO of make L&T or techno-commercially equivalent of ELMEASURE/SECURE. (b) Indicator lamp with integral circuit (230/240V) & cluster LED (Red, Orange, Blue) - 01 Set. (c) Danger notice plate of size 20 x 15 cm of 1.6mm thick mild-steel sheet, vitreous enamelled white, with letters, figures and conventioinal skul and bones in signal-red colour and fixed with MS clamps, bolts and nuts of approved size, for LT conforming to IS-2551 - 02 Nos (Front & Back).

-

-

-

... More
Supply, install, commissioning & testing of LT control panel board "out-door type" of appropriate size / dimensions factory fabricated CPRI approved (type-tested) with suitable neoprene rubber gasket to make it completely dust & vermin proof & degree of protection not less than IP-55 & general construction confirming to IS-13947, double door, front & back openable. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation & tinned copper bus-bar wrapped with coloured PVC tape/sleeves of rating in conformity to the Incoming ACB/MCCB rating. The panel board shall be fabricated out of 3.15 mm thick (for outer portions) & 2.0 mm thick (for inner portions) CRCA sheet duly pre-treated & powder coated, supporting angle iron frame & MC channel base suitable for 3 Ph, 4 wire system 415/440 volts grade incl complete internal wiring with not less than 2.5 sqmm copper wire incl cable glands of suitable sizes incl suitable PCC (1:3:6) type C-2 foundation , necessary earthwork (if any) complete all as specified and as directed with & incl the following accessories : [ LT Panel - 08 ]

1

60

-

... More
BUS-BAR & INTERNAL CONNECTIONS : The bus-bars shall be made up of 04 Nos high grade Aluminium 100 A rated, duly insulated with 1100 V grade standard colour coded PVC sleeves & rigidly mounted on suitable sized "F" class insulators of non-hygroscopic, non-combustible, all internal connections from main bus-bars to switch gears etc. PROVISION FOR CABLE ENTRY : The provision for cable entry/exit shall be provided in the bottom for both incoming & out-going cables with the help of glands matching the existing LT cable sizes. INCOMING : (a) MCCB 4P (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting,suitable for isolation, having breaking capacity 25 KA & of rating 64 to 80 A - 01 Nos. Make : Cat No : DZ0F0080CXC1AOOOO of Make L&T or techno-commercially equivalent of LEGRAND/SIEMENS.

-

-

-

... More
OUTGOINGS : (a) MCCB 4P (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting,suitable for isolation, having breaking capacity 25 KA & of rating 26 to 32 A - 05 Nos (1W + 1S). Make : Cat No : DZ0F0032CXC1AOOOO of Make L&T or techno-commercially equivalent of LEGRAND/SIEMENS. (b) MCB, TPN, 10KA, 415V, "C" curve, 06-32 A, ISI marked - 01 Nos. Make : L&T/ABB/SIEMENS

-

-

-

... More
INSTRUMENTATION SYSTEM : (a) Digital type Multi-Function meter with built in selector Switch & 03 Nos CTs matching with the I/C breaker, Accuracy Class - 1.0, 3 phase, Size 96 x 96 mm. Make : Cat No WL411010OOOO of make L&T or techno-commercially equivalent of ELMEASURE/SECURE. (b) Indicator lamp with integral circuit (230/240V) & cluster LED (Red, Orange, Blue) - 01 Set. (c) Danger notice plate of size 20 x 15 cm of 1.6mm thick mild-steel sheet, vitreous enamelled white, with letters, figures and conventioinal skul and bones in signal-red colour and fixed with MS clamps, bolts and nuts of approved size, for LT conforming to IS-2551 - 02 Nos (Front & Back).

-

-

-

... More
Supply, install, commissioning & testing of Street/Perimeter light Control Panel suitable for 6.0 KW load, Contactor Rating 32 A TP, MCB Rating 40 A TPN, Digital 24 hour switch suitable for mounting inside LT Panel for automatic operation complete all as specified and as directed. Make : Cat No IHXTS03060 of Make Havells or techno-commercially equivalent confirming to IS/IEC 61439 & 60529 with & incl extended wide band coil, FRLS internal wiring, in-built short-circuit protection, Class H insulation.

10

64

-

... More
IMPORTANT NOTES for ITEM Nos 32 to 39 : 1) Design / drawing / BOM of the Panel Board incl all accessories showing the dimensions is to be obtained from the Manufacturer / Supplier along with valid CPRI Type-test Certificate & is to be got approved from the Engr-In-Charge & GE before placing final order to the manufacturer. 2) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates. 3) The electrical connection of digital Multi Functional Meter in the LT panel is to be done from load side so that monitoring of various parameters viz. Voltage, Current, KW, KVA, power factor, frequency etc. can be done for both SEB mains & DG mains (if any) whereever applicable. 4) Necessary PCC foundation/plinth shall be as per the recommendations of OEM & cost of the same is deemed to be included in the quoted rates. 5) Quoted rate is deemed to be inclusive of dismantling / taking down of old / unsv / damaged one. 6) Quoted rate is also deemed to be inclusive of MCCB Spreader Links etc. for proper & successful connection of the LT UG Cables complete to the entire satisfaction of the Engr-In-Charge.

-

-

-

... More
S & F TPN DB, 4 Way, IP43, IK09, Metal double door type 415 volts fitted with busbar and blanking plates, neutral link and making good making good the disturbed surfaces with all other accessories including necessary connection complete all as specified and as directed. Make:-L&T/LEGRAND/SIEMENS/ABB.

14

66

-

... More
S & F SPN DB, 12 Way, IP43, IK09, Metal double door type 240 volts fitted with busbar and blanking plates, neutral link and making good making good the disturbed surfaces with all other accessories including necessary connection complete all as specified and as directed. Make:-L&T/LEGRAND/SIEMENS/ABB.

75

67

-

... More
S&F MCB, TPN, C-Series 415 Volts of capacity 16-32 Amps with breaking capacity 10 KA complete all as specified and as directed. Make :-L&T/LEGRAND/SIEMENS/ABB.

28

68

-

... More
S&F MCB, SPN, C-Series 240 Volts of capacity 6-32 Amps with breaking capacity 10 KA complete all as specified and as directed. Make :-L&T/LEGRAND/SIEMENS/ABB.

145

69

-

... More
S&F MCB, SP, C-Series 240 Volts of capacity 6-32 Amps with breaking capacity 10 KA complete all as specified and as directed. Make :-L&T/LEGRAND/SIEMENS/ABB. NOTE for Item Nos 40 to 44 : Make of MCBs shall be same as the make of MCB DBs.

764

70

-



Evaluation Notes How It Works ?

Related Tenders

Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.