For getting the details of etenders, if you are looking for information about them from the cumbersome government websites but are tired of doing so, Bidassist comes up with a one stop solution. It collates every Eproc telangana tender on Bidassist. One can approach it for the bidding process, registration process, etc., are explained below.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date27 May 2025
Closing Date30 May 2025
Tender Amount₹ 79,95,000 
Notes
Download

Costs

Summary

Repairs Replacement Nd Maintenance Gang Operated Switch 2 4 Pole Structure Ht Cable Transformers, Calibration Of Vcbs Equipment And Body Earthing And Ht Switch Gears, Ht Distributions System, Earthings At Bowenpally Area Under Age Em-i Area Of G

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Removing excavated material (soils) n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified.

112

10

-

... More
M & L for sand cushioning to underground cable including punning down of sand in layer complete all as specified. Note :- Thickness of sand cushion after punning down i.e 18 Cm shall be measured for payment

85

10

-

... More
M&L for PCC 1:3:6 type C2 (40mm graded aggregates) as in foundation, filling and mass concrete complete all as specified.

28

10

-

... More
M&L for cement concrete 1:3:6 type C-1 using 20mm graded stone aggregates as in coping / pedestal of poles including necessary formwork complete all as specified.

2.2

10

-

... More
Supply and lay un-reinforced precast concrete cable cover , class , HV , Type 2 flat size 450 x 180 x 40 mm laid dry in trenches over under ground cables.

4400

10

-

... More
Supply and lay un-reinforced precast concrete cable cover , class , HV , Type1 flat size 300 x 180 x 40 mm laid dry in trenches over under ground cables.

2200

10

-

... More
M&L Cableguard DWC HDPE Cable Duct Pipes of size 150 mm dia complete all as specified.

600

10

-

... More
Supplying, Erecting and fixing in replacement Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-55 (11.0 meters long) and providing 3 Nos of 30cm wide circular bands with black & yellow paint starting from plinth level at a gap of 30 cm in between 2 bands and numbering of poles, in yellow paint over black painted back ground at a height of 2m from bottom of pole with 5 cm large bold letters 2" wide, complete all as specified.

23

10

-

... More
Supply and laying in repairs/replacement of old with new XLPE insulated (Earthed) , screened PVC bedded, galvanized steel strip or wire armored, electric power cables(heavy duty) with aluminum conductor, 11000 volts grade,3 core, cross sectional area 95 sq.mm including inspection and testing complete all as specified .

1000

10

-

... More
Supply and laying in repairs/replacement of old with new XLPE insulated (Earthed) , screened PVC bedded, galvanized steel strip or wire armored, electric power cables(heavy duty) with aluminum conductor, 11000 volts grade,3 core, cross sectional area 120 sq.mm including inspection and testing complete all as specified .

200

10

-

... More
Supply and laying in repairs/replacement of old with new XLPE insulated (Earthed) , screened PVC bedded, galvanized steel strip or wire armored, electric power cables(heavy duty) with aluminum conductor, 11000 volts grade,3 core, cross sectional area 185 sq.mm including inspection and testing complete all as specified .

345

10

-

... More
M & L for Cable jointing kit for 11 KV (Earthed) grade cable for Straight through heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armored aluminum conductor cable of size 95 sqmm including taking down of old unserviceable joint kit complete all as specified.

11

10

-

... More
M & L for Cable jointing kit for 11 KV (Earthed) grade cable for Straight through heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armored aluminum conductor cable of size 120sqmm to 185 sqmm including taking down of old unserviceable joint kit complete all as specified.

9

100

-

... More
M & L for Cable jointing kit for 11 KV (Earthed) grade cable for outdoor end termination heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminum conductor cable of size 95 sqmm including taking down old unserviceable complete all as specified .

20

100

-

... More
M & L for Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminum conductor cable of size 95 sqmm including taking down old unserviceable complete all as specified .

2

100

-

... More
M & L for Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminum conductor cable of size 120 sqmm to185 sqmm including taking down old unserviceable complete all as specified .

18

100

-

... More
S&F in repaire/replacement, cable route indicator for HT UG cable of 11000 volts bolted with 40x6 mm flat iron member of height 0.60 mtrs and 80 mm CI plate embedded in PCC 1:3:6 type C2 of size 20x20x30 cm block complete all as specified.

98

100

-

... More
S & F in repaire/replacement, Cross arms, bracing, supports, clamps and back plate, fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as directed including two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified .

6

100

-

... More
supply and fixing in repairs/replacement of pin type porcelain , vitreous, white, brown or green insulator including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut, 150 mm height and 150 mm dia suitable for working pressure 11000 Volts grade complete all as specified.

33

100

-

... More
supply and fix in repaire/replacement, disc type insulator, porcelain, vitreous, white brown or green, 145mm high, and 255mm dia ball and socket type single disc assembly for tension with tension clamps for conductors, working pressure 11000 volts grade complete all as specified.

33

100

-

... More
S&F post of insulator 11 KV suitable for air break switch/drop out fuse with necessary nuts, bolts washers complete all as specified .

11

100

-

... More
S&F in repaire/replace of air break switch rocking type Gang operated triple pole mechanically operated mounted on insulator and steel frame with operating mechanism worked from ground level for current rating up to 400 Amps suitable for 11000 volts complete all as specified

4

100

-

... More
M&L for earthing complete with GI earth plate electrode of size 60cm x 60cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5m below the normal ground level connected with GI wire 4mm dia by means of bolts, nuts, check nuts & washers of galvanished iron steel including necessary excavation and earth work in any type of soil, removing surplus soil to a distance not exc 50m, with and including PCC chamber in PCC (1:2:4), type B1,using (20mm graded stone aggregate),"mild steel angle iron frame" made out of MS angle iron of size 40x40x6mm thick duly painted with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer hinged with and including 6mm thick CI cover with handle, watering arrangement with funnel internally secured with wire mesh with 20mm dia medium grade pipe for watering 40mm dia light grade, GI pipe for lead protection in and including alternate layers of charcoal dust and common salt complete all as shown in electrical "plate No '3' and connected to earthing test point all as specified and indicated including testing on completion including retrieving old GI earth plate, CI cover, GI pipes, angle iron frame from existing earthing complete all as specified and directed. Note 1: The unit rate shall also include for earth work in any type of soil, PCC 1:3:6 type C1 chamber, 50mm thick RCC 1:2:4 type B-1 using 20mm graded stone aggregate cover slab reinforced with 6 Nos of 8mm dia TMT bars both ways, funnel with watering pipe 20mm dia medium grade, GI protection pipe medium grade 15mm dia and wire mesh complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub-heading earthing, specified on Sl Page No. 422 of SSR Part-II. 2. GI earth Strip beyond 7.5m will be measured and paid separately.

20

100

-

... More
M&L for earthing complete with GI earth plate electrode of size 60cm x 60cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5m below the normal ground level connected with GI earth strip 25x4mm by means of bolts, nuts, check nuts & washers of galvanished iron steel including necessary excavation and earth work in any type of soil, removing surplus soil to a distance not exc 50m, with and including PCC chamber in PCC (1:2:4), type B1,using (20mm graded stone aggregate),"mild steel angle iron frame" made out of MS angle iron of size 40x40x6mm thick duly painted with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer hinged with and including 6mm thick CI cover with handle, watering arrangement with funnel internally secured with wire mesh with 20mm dia medium grade pipe for watering 40mm dia light grade, GI pipe for lead protection in and including alternate layers of charcoal dust and common salt complete all as shown in electrical "plate No '3' and connected to earthing test point all as specified and indicated including testing on completion including retrieving old GI earth plate, CI cover, GI pipes, angle iron frame from existing earthing complete all as specified and directed. Note 1: The unit rate shall also include for earth work in any type of soil, PCC 1:3:6 type C1 chamber, 50mm thick RCC 1:2:4 type B-1 using 20mm graded stone aggregate cover slab reinforced with 6 Nos of 8mm dia TMT bars both ways, funnel with watering pipe 20mm dia medium grade, GI protection pipe medium grade 15mm dia and wire mesh complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub-heading earthing, specified on Sl Page No. 422 of SSR Part-II. 2. GI earth Strip beyond 7.5m will be measured and paid separately.

14

100

-

... More
M&L for earthing complete with copper earth plate electrode of size 60cm x 60cm x 3.15 mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5m below the normal ground level connected with copper Strip20 x 3 mm dia by means of bolts, nuts, check nuts & washers of galvanished iron steel including necessary excavation and earth work in any type of soil, removing surplus soil to a distance not exc 50m, with and including PCC chamber in PCC (1:2:4), type B1,using (20mm graded stone aggregate),"mild steel angle iron frame" made out of MS angle iron of size 40x40x6mm thick duly painted with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer hinged with and including 6mm thick CI cover with handle, watering arrangement with funnel internally secured with wire mesh with 20mm dia medium grade pipe for watering 40mm dia light grade, GI pipe for lead protection in and including alternate layers of charcoal dust and common salt complete all as shown in electrical "plate No '3' and connected to earthing test point all as specified and indicated including testing on completion including retrieving old GI earth plate, CI cover, GI pipes, angle iron frame from existing earthing complete all as specified and directed. Note 1: The unit rate shall also include for earth work in any type of soil, PCC 1:3:6 type C1 chamber, 50mm thick RCC 1:2:4 type B-1 using 20mm graded stone aggregate cover slab reinforced with 6 Nos of 8mm dia TMT bars both ways, funnel with watering pipe 20mm dia medium grade, GI protection pipe medium grade 15mm dia and wire mesh complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub-heading earthing, specified on Sl Page No. 422 of SSR Part-II. 2. GI earth Strip beyond 7.5m will be measured and paid separately.

34

100

-

... More
S&F in repairs, Earth continuity conductor with 20x3mm copper strip fixed to wall on batten or recess or chases with necessary porcelain insulators or buried in ground or drawn in conduit/pipe/wall or fixed to poles or any other indicated situation for loop earthing etc including taking down of old unserviceable copper strip complete all as specified and as directed.

80

100

-

... More
S&F in repairs, Earth continuity conductor with 25x4mm GI strip fixed to wall on batten or recess or chases with necessary porcelain insulators or buried in ground or drawn in conduit/pipe/wall or fixed to poles or any other indicated situation for loop earthing etc including taking down of old unserviceable copper strip complete all as specified and as directed.

50

100

-

... More
Supply and spread and leveling Graded coarse Aggregate in loose filling over the sand of gauge 63 mm nominal size in the installation yard all as specified.

80

100

-

... More
Supply only Female contact or fixed contact heavy duty and high conductive metal assembly brass/Gun metal complete capacity 400 Amp 11 KV including taking down old contact complete all as specified and as direcred.

3

100

-

... More
Supply only Male contact or Moving contact blade heavy duty and high conductive metal assembly brass/Gun metal complete capacity 400Amp 11 KV including taking down old contact complete all as specified and as directed.

3

100

-

... More
Supply only Tinned copper flexible jumper 200A/400A Make Rastriya/Jaipuria including taking down old jumper complete all as specified and as directed.

9

100

-

... More
Dismantling of UNSV stay assembly complete with stay insulator all as specified

2

100

-

... More
Supply and fill in replacement ,Silica Gel in transformer of any capacity/ any make including taking down old silica gel complete all as specified .

1

100

-

... More
S&F, in repaire/replacement Danger notice plate of 1.6mm thick mild steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20 cm size all as specified .

20

100

-

... More
Supply and lay in repaire/replacement, Synthetic Rubber insulated Mats of size 2.5 mm thick, 1 m wide, 2 m length for working voltage upto 11 KV, for electrical purpose conforming to IS 15652:2006 (Superseding IS 5424) suitable for electric shock safety complete all as specified and directed.

10

100

-

... More
Supply only Tinned copper fuse wire of 16 SWG to 22 SWG or 30 Amps to 200 Amps capacity suitable for 11 KV

3

100

-

... More
M&L for cleaning/painting of 4 Pole structure/2 pole/Single pole structure of any type/size/lenght and removing existing painting by using wire brush using with emery paper and cleaning with chemical agents, after cleaning the poles two coats of red oide primer and two coats of synthetic aluminium painting satisfactorily by Engr-in-Charge and painting work carryout at any height and including marking of pole numbers as directed and safety eqpts & Tools will be own arrangement and making and colour washing of pole coping all as specified and directed of the followings : -

-

-

-

... More
(a)Two Poles with cross arms complete

17

100

-

... More
(b)Four Poles with cross arms complete

15

100

-

... More
(c) Single HT 11 mtrs Pole with cross arms complete

25

100

-

... More
Cutting the existing road straight by manual, depth and width not less than 1 mtr below ground level for passing of underground cable and filling back with excavated soil upto 75% road portion and 25% shall be made with cement concrete 1:2:4 (using 20 mm graded aggregate stone complete all as specified and directed. Note: Necessary work permissions for the works to be carried in Civil/Public ares/Defence areas to be taken by the contractor prior to starting the work. Laision with concerned departments is the responsibility of contractor. Department will do the necessary authorised correspondence for the said approvals. No extra payment will be entertained on this account.

50

100

-

... More
Cutting anxious green growth/vegetation growth for cleaning out the area around transformer installations, E/M installations and four pole structure yards at ground level by cutting out roots, un wanted plants bushes and removal of the same by surface excavation not exceeding 30 cm deep average 15 cm

2200

100

-

... More
M&L stone masonary (H shape) platform of size 2.5m x 2.5 m x 1.5 m in cement mortar 1:6 with PCC foundation 1:4:8 type D-2 using 20 mm graded stone aggregate, PCC 1:2:4, type B-1 using 12.5 mm graded stone aggregate, 20 cm thick coping over brick work, plastering to exposed surfaces of brick work with cement mortar 1:4, 15mm thick.

2

100

-

... More
M&L for Shifting of the any make of transformer rating up to 500 KVA mounted on plinth/pole from existing location to new location and existing transformer vice versa, including removing and reconnections of HT/LT side, jumper / cable connection, control cable connection of both transformers including testing and commission complete all as directed. Note:- (i) The rate quoted is deemed to be inclusive of necessary crane / vehicle charges for shifting and installation of the transformer.

1

100

-

... More
Dismantling HT/LT pole of any height by taking out from PCC foundation complete and shifting to other location as directed including fixing the pole in true vertical position including excavation and earth work, PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as base concrete and PCC 1:3:6 type C2 (using 20mm graded stone aggregate) in both foundation and coping of poles all as specified in SSR Part I-2009 and applying two coats of aluminium paint to pole surface complete all as directed

1

100

-

... More
Fixing only chain link fencing including line wires any mess size and type to any type of standards, rails, straining bolts, etc including provision of binding wire complete all as specified and as directed.

100

100

-

... More
Supply only Chain link MS galvanisd fencing, 4.00mm dia and 50x50 mm size complete all as specified and as directed.

300

100

-

... More
Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete.

100

100

-

... More
M&L for applying two coats of synthetic enamel paint over a coat of red oxide primer including prepration of surface all as specified and directed

10

100

-

... More
M&L for Brick work with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius, using cement mortar of 1:6 class including plastering of brick work complete all as specified and as directed.

10

100

-

... More
S&Fin repairs 100 mm dia GI pipe light grade fixed to walls/poles or laid in trenches, road crossing etc., for protection of underground cable/earth strip including sealing ends with hessian cloth impregnated with bituminous compound in ground and with teak wood bushes for ends fixed on walls/poles complete all as specified and directed.

12

100

-

... More
Supply and lay in replacement of GI tubing 80 mm dia, light grade for cable protection at road crossing / on poles and tubing sealed at both ends after laying the cables complete all as directed.

12

100

-

... More
M&L for boring of horizontally holes under the road/boundry wall below 1.0 mtr from the road/hard surface by trenchless techonology using ultra sound technique and inclduing necessary machine without damaging the existing road and getting out in any type of soil and disposal of soil to a distance not exceeding 50m from the site of work including supply & laying HDPE pipe up to 150 mm dia suitable for 0.4 MPA work pressure . NOTE: AVERAGE WIDTH OF THE ROAD IS 20 RM. Necessary permissions required from state Govt and other Civil bodies for doing the job is the responsibility of contractor.

30

100

-

... More
Supply, laying in replacement, in trenches /ducts/fixing on pole/STR with suitable size of GI clamps made out of GI strip 32 mm x 6 mm, XLPE insulated, screened, earthed, PVC bedded, galvanised steel strip, electric power cable (heavy duty) of size 3 x 95 sqmm with aluminium conductor suitable for 11 KV (E) grade as per relevent IS including latest amendment for IS (ISI marked cable) testing, commissionong along with suitable foundation complete all as specified and directed including taking out of old burnt out cable alongwith cable covers. Note:- (a) Earth work, EHV cable cover, sand coushioning & GI pipe will be measured and paid seperately. (b) High voltage test to be conducted at site with suitable voltage before and after laying of HT cable and reading shall be recorded jointly and test report to be submitted in triplicate to the Engineer-in-Charge. The cost of the same shall be deemed to be included in the unit rate quoted above.

1110

100

-

... More
Supply, test, install & commissioning in replacement of HT 11 KV outdoor type gang operated air break switch triple pole mechanically operated suitable for horizontal or vertical mounting(suitable for existing one) on insulator and steel frame with operating mechanism worked from ground level for current rating up to 400 Amps and connecting up with jumpers, testing and commissioning including dismantling/disconnecting & taking down the old unserviceable one complete all as directed by Engr-in-Charge. Make :- VJV / SMC / ATLAS/JAIPURIA

4

100

-

... More
M & L for servicing, greasing, cleaning of GOD, adjustment of its operation, cleaning and checking (for any type of damage) of insulators and lightening arresters incl. tightening of all loose nuts & bolts on the HT structure at site complete all as specified and directed by Engineer-in-Charge. NOTE :- 1. All the necessary tools, tackles and ladder shall be arranged by the contractor for the subject work. 2. Contractor has to arrange for necessary cleaning agent (petrol, diesel, CRC 2-26 etc.) and lubricating material like grease, oil and lubricating sprays if any, as required for subject work. 3. Major spares required to be replace during servicing will be measured and paid under relevant item as specified.

10

100

-

... More
M&L in replacement of fixed type top contact for DO fuse units 11 kV in replacement complete all as specified and directed.

10

100

-

... More
S&F , testing and commissioning in replacement of Male contact (gunmetal) suitable for Horizontal/vertical operating type GOD 11 KV grade, 200 Amps rating in position as in replacement complete.

10

100

-

... More
All as per srl item No. 58 but Female gunmetal contact.

10

100

-

... More
All as per srl item No. 58 but Tinned copper flexible jumper.

10

100

-

... More
All as per srl item No. 58 but MS Jumper carrier.

10

100

-

... More
All as per srl item No. 58 but Back connector plate.

10

100

-

... More
M&L in replacement of GI pipe of size not less 25mm dia, medium grade, as down rod levers coupling & operating handle of the existing GOD cut to suitable length including fixing up the same and commissioning of the respective GOD complete incl taking down unsv one. NOTE - The quoted rate is deemed to be inclusive of cost of threading, cutting of pipe incld. cost of nut, bolts, washers, etc. minor items required for the efficient operation of GOD.

6

100

-

... More
Supplying, fixing, connecting and testing in repair/replacement of , single pole zinc oxide (gap less surge type), heavy duty, station class, self supporting outdoor type lighting arresters having rated voltage 09 KV (RMS), discharge current 10 KA insulation level 28/75 KV/KVp (peak) suitable for rated system voltage of 12 KV supply system with maximum continuous operating voltage (MCOV) not less than 7.65 KV (RMS) with highly non linear ceramic resister made of zinc oxide in dermetically sealed container, complete, with metal base, base insulator and suitable terminals for ground connections and pressure relieving arrangement complete incl taking down old unsv one all as specified and directed.

2

100

-

... More
M&L in replacement of ACSR jumpers in HT/LT over head line upto 10 mm dia as that of existing size including binding wire, nuts & bolts washers complete incl taking down old unsv one all as directed

20

100

-

... More
M&L for Opening top cover of transformer taking out complete oil and keeping in clean and dry container, taking out core & winding from the body,remove the sludge from tank complete and segregation of HT/LT coil from transformer including job assembling of jointing the connections pf HT/LT coil in core assembling complete insulation works, setting of core, making new connections (as per existing connections), proper alignment of job including keeping in oven chamber of as per IS Specification of respective transformer capacity for remove the moisture as well as fixing of upper yoke lamination, checking, tightening, nuts, bolts, washers and all types of gasket ( Bushing and tank) etc and welding if any leakage found in body or fins, making good dificient item if any, testing the jobs with megger for proper results including two coats of anti corrosive paint aftre cleaning inside transformer tanks and two coats of outside painting including writing KVA Capacity, repairs of body by means of welding, jointing if required complete for capacity 200 KVA and upto 400 KVA with complete Testing and Commissioning all as directed .

4

100

-

... More
M&L in replacement of Making Primery/Secondary coil with insulating copper wire of required gauge craft paper cotton tape HT/LT insulation as per specification of old existing transformer including making of coil as required of various capacity of transformer complete all as directed.

360

100

-

... More
M&L in replacement of ACSR conductor, steel reinforced for LT / ht over head lines on poles including streching tightining of poles insulator with binding wire of suitable size with insulator/streching of ACSR conductor including disconnecting/taking out old existing unsv ACSR conductors complete all as specified and directed.

0.2

100

-

... More
M&L for Disconnection of all Primary/Secondary connections of the defective transformer rating up to 200kVA out door / indoor type, any make, taking down / out from plinth / pole / platform with the help of suitable crane and transporting the same carefully to workshop for repair and bringing back and test, install & commissioning in its original existing position by making all neccessary connections complete all as directed by Engr-in-Charge. Note :- Crane and Transporting Charges including in the Job.

2

100

-

... More
M&L for Disconnection of all Primary/Secondary connections of the defective transformer rating above 200 kva and up to 400kVA out door / indoor type, any make, taking down / out from plinth / pole / platform with the help of suitable crane and transporting the same carefully to workshop for repair and bringing back and test,install &commissioning in its original existing position by making all neccessary connections complete all as directed. Note :- Crane and Transporting Charges including in the Job.

2

100

-

... More
M&L for Opening top cover of transformer taking out complete oil and keeping in clean and dry container, taking out core & winding from the body,remove the sludge from tank complete and segregation of HT/LT coil from transformer including job assembling of jointing the connections pf HT/LT coil in core assembling complete insulation works, setting of core, making new connections (as per existing connections), proper alignment of job including keeping in oven chamber of as per IS Specification of respective transformer capacity for remove the moisture as well as fixing of upper yoke lamination, checking, tightening, nuts, bolts, washers and all types of gasket ( Bushing and tank) etc and welding if any leakage found in body or fins, making good dificient item if any, testing the jobs with megger for proper results including two coats of anti corrosive paint aftre cleaning inside transformer tanks and two coats of outside painting including writing KVA Capacity, repairs of body by means of welding, jointing if required complete for capacity up to 200 KVA with complete Testing and Commissioning all as directed.

4

100

-

... More
M&L for Reconditioning of over heated HT/ LT coil of transformer up to 400 KVA after removing all old insulation any type and re-insulation with insulated craft paper cotton tape Class'F' insulation as required complete all as directed.

4

100

-

... More
M&L for Opening of the 11 KV / 0.433 KV Distribution transformer rating up to 500 KVA by removing the inspection cover / top cover, decanning of the transformer oil up to the required level,check leaked cork seal(if any), check the un sericeable insulators & LT/HT bush (if any) complete from the shell and making connections of LT/HT bush,insulators & cork seals to avoid leakage and refilling oil back to existing postion into the transformer complete testing & commissioning complete all as directed. Note: Spares shall be measured and paid separately under relevant items.Necessary arrangement for repairs on timely basis at site to be madebt contractor and minor items like cork seal, insulators,bolts,nuts and washers required for arresting leakages are deemed to be included in quoted rate.

4

100

-

... More
S&F in replacement of renewal of transformer/Servo Transformer bushing LT side including brass set stems conical bush/gasket for indoor/outdoor transformer incl taking down old unsv one for the following capacity :- Note : The rates quoted is deemed to be included the cost of necessary labour charges for draining out transforer oil, opening of top cover by unscrewing nut, bolts washers and and suitable size pad type bus bar almuminium and nut pach washers etc

-

-

-

... More
Upto 160 KVA

2

100

-

... More
200 KVA to 400 KVA

2

100

-

... More
S&F following accessories of transformer in replacement of unserviceable, incl taking down old unsv one complete all as directed :-

-

-

-

... More
(a) Top cover gasket of FOR DISTRIBUTION TRANSFORMER OF 50-500 KVA any capacity as per site requirement.

2

100

-

... More
(b) Temp gauge 0-100 degree Celcius suitable for distribution transformer 11/0. 433 KVA of Capacity upto 400 kva

1

100

-

... More
(c ) Porcelain transformer bushing HT 11 KV including brass set stems conical bush/ gasket for indoor/outdoor transformer upto 500 KVA as per IS-3347 complete all as specified and as directed.

2

100

-

... More
(d) LT rod / studs for any make of transformer rating up to 160KVA mounted on pole/plinth, made of brass with nut and washers, Insulator and fittings etc as per size and shape of original complete including taking down old u/s one complete all as directed.

2

100

-

... More
(e) LT rod / studs for any make of transformer rating up to 200KVA to 400 KVA mounted on pole/plinth, made of brass with nut and washers, Insulator and fittings etc as per size and shape of original complete including taking down old u/s one complete all as directed.

2

100

-

... More
Replacement of moisture saturated silca jel breather assembly with new one including vent pipe for indoor/outdoor transformer incl taking down old unsv one of the follolwing capacity :-

-

-

-

... More
Upto 160 KVA of Cap 250g

8

100

-

... More
200 KVA to 400 KVA of Cap 500g

8

100

-

... More
Replacment / Renewal of Silica gel for filling in existing air breather by removing old one

3

100

-

... More
Arresting leakage of transformer fins by brazing / welding etc, after removing of oil from inside of transformer and refilling of oil by opening top cover of transformer of capacity upto 500KVA

2

100

-

... More
Supply and filling in replacement of transformer oil pole or plinth mounted as per IS :335 with 60 KV Dielectric strenght specified and directed.

750

100

-

... More
M&L for dehydration including filtratrion cleaning of transformer oil testing of Dielectric strenght of transformer oil of indoor/outdoor type transformer 11/.433KV . filtration of transformer oil by passing through filtration machine/plant to remove moisture impurities and for improving dielectric strenght to above 60KV for 2mm gap and machine having minimum capacity 1000 to 30000 ltrs/hours. Testing of insulation and vescocityof oil before and after dehydration to be carried out site. Note :- Contractor carryout the filtration at site by machine which automatically collect data of dielectric strenght and printout out of the same shall be Submitted to the department.

1500

100

-

... More
M&L for Shifting of the any make of transformer rating up to 500 KVA mounted onplinth/pole from existing location to new location and existing transformer vice versa, including removing and reconnections of HT/LT side, jumper / cable connection, control cable connection of both transformers including testing and commission complete all as directed by Engr-in-Charge. Note:- (i) The rate quoted is deemed to be inclusive of necessary crane / vehicle charges for shifting and installation of the transformer.

2

100

-

... More
Dismantling HT/LT pole of any height by taking out from PCC foundation complete and shifting to other location as directed including fixing the pole in true vertical position including excavation and earth work, PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as base concrete and PCC 1:3:6 type C2 (using 20mm graded stone aggregate) in both foundation and coping of poles all as specified in SSR Part I-2009 and applying two coats of aluminium paint to pole surface complete all as directed.

2

100

-

... More
Inspection of defective 11kv HT cable(laid in UG/trench/tunnel/wall/surface) to locate the fault using cable fault Locator machine(by surge generators mounted on Van) (fault either by Short/Moisture/earth fault or any type) including complete all as directed.

4

100

-

... More
M&L for Spray painting of upto 400 KVA transformer pole mounted / plinth mounted at site and applying two coat of synthetic enameled Smoke grey paint after removing all dust & rust and paint shall confirm to IS 2032 including marking or transformer capacity with stencil letter with black or white paint and Font and Size of letter shall be directed, complete all as specified and directed.

6

10

-

... More
Maintenance of earthings of installations like cleaning of earth pits, treatment of earthing by pauring salt water, replacement of perished wire mesh, unserviceable funnel and repair works like patch works to the PCC chambers and RCC cover with cement mortar 1 : 4 all as directed.

15

10

-

... More
Dismantling and taking out existing Expulsion fuse unit single pole 11 KV channel mounted complete including supply and fix for new Expulsion fuse unit single pole 11 KV, above 50 & 100 amp channel mounted complete

3

10

-

... More
Cutting and trimming trees branches any girth and any size touching to overhead lines and cleaning the distance 1.5 mtr length both side of OH line with in a span of upto 50 mtrs each disposing the same, clearing the site all as directed .

40

10

-

... More
Surface excavation not exc 30 cm deep and averaging 15cm deep and getting out HARD / DENSE soil

400

10

-

... More
M&Lfor single filling in floors or pavings of Gauge 40 mm to 90mm, deposited, spread and levelled in layers not exc. 150mm thick, watered and rammed to a True Surface, complete all as specified and as directed.

100

10

-

... More
Supply & Laying in replacement of Insulating mats 2.5mm thick made of Elastomer (a generic term that includes rubbers, latex and elastomeric compounds that may be natural or synthetic or a mixture or a combination of both) for use as floor covering for the protection of workers on ac and dc installations with the system voltages up to 11 kV ac and 240 V dc and as per Cl 5 of IS15652 latest Class B Cat II of Size 1m X 2m complete with Relevant Test Reports and fixing on floor with suitable adhesives complete incl taking down old unsv one all as specified and as directed Note:- The mat should be permanently pasted with the help of suitable adhesive/resin. All joints and comers shall be filled/covered wit,hinsulating material of matching colour. Matching colour and matching designed tapes should be used to maintain an aesthetic look of the installation.

20

10

-

... More
Taking down HT switch gear (Vacuum circuit breaker ) of capacity 400 to 800 Amps, 11 KV 250 to 450 MVA comprising of following repairs, overhauling, servicing and refixing the same after repairs/ overhauling: (a) Tripping off the breaker, lowering the breaker with raising/lowering handle and pulling out the breaker complete from the panel along with the trolley for servicing/inspection/overhauling (b) Servicing/Inspecting/checking of automatic safety shutter operation for serviceability and replacement of spares if required. (c) Servicing/Inspecting/checking of circuit spout and cicuit spout connections for RYB phases and replacement of spares if required. (d) Dismantling and checking of cross bar assembly, fixed contacts and current carrying parts of the breaker, trolley, insulated assembly and checking lamination with clamps, epoxy spout, isolator assembly etc. (e) Setting, reassembling, cleaning, adjustment of fixed contacts, main contact, arcing contacts and chamber baffle pot assembly, moving contact for proper setting of auxiliary contacts operating mechanism. (f) Servicing/Inspecting/checking of secondary sockets/busbar earthing plugs/earthing sockets and replacement of spares if required.

2

10

-

... More
(g) Checking, setting and adjustment of lowering and raising operation of the breaker trolley. (h) Lubrication and greasing of all moving parts of the trolley, stopper bolt for proper operating and closing of shutter gear, isolation resistance of trolley of with vacuum interrupter assembly. j) The inspection of HT switch gear shall involve:- (i) Inspection of truck & hoist assembly. (ii) Inspection of tank assembly & barriers. (iii) Inspection of assembly & components of solenoid assembly. (iv) Inspection of assembly & components of dependent mechanism. (v) Inspection of assembly & components of spring box mechanism. (vi) Inspection of motor mechanism spring charge assembly (vii) Inspection of assembly of trip unit & related components

-

-

-

... More
Notes: (i) The rate quoted shall be deemed to include for necessary T&P, nuts, bolts, washers, gasket, insulation tape, compound etc. to put in to the VCBs and panels in serviceable condition, testing and commissioning all as specified and as directed by the Engineer-in-Charge. (ii) Major spares like Breaker bushings, vaccum interrupture assly, busbar spout, busbar spout connections, circuit spout/circuit spout connections/buffer fixed contacts, moving contacts, tank assly/barriers, solenoid spares, dependent/spring mechainsm/ motor mechanism, trip unit etc will be measured and paid separately under relevant items of Schedule 'A. However the rate quoted shall be deemed to include of fixing/ replacement and taking down old unsv one

-

-

-

... More
M/L for strip opening the HT panel of rating 11 KV, 3 phase comprising of following repairs, inspecting, overhauling and servicing/ re-fixing of the spares etc complete all as directed: a) Dismantling the complete instrument chamber/ HV cable box/LV cable box .Decarbonising/ cleaning the complete HT 11 KV 3 phase independent bus bar, bus bar chamber of HT panel and inspecting the bus bar insulators. b) Checking, inspecting, calibration of IDMT relays complete. c) Checking complete electrical tripping circuit of HT panel including control wiring from secondary system rotary to tripping coil, auxiliary switch male and female housing cut out, etc. and wiring including replacement of damaged wire at places including operation on DC system, testing and commissioning complete all as directed. d) Inspection of CTs and PTs if any. Replacing the defective CT/PTs incl accuracy in checking of the CT wiring with primary and secondary injection kit including identification to the base and connecting links to main switch including taking down unserviceable current transformer complete all as directed e) Inspecting of indicating lamps, rotary switches/selector switches, toggle switches etc complete

2

10

-

... More
Notes: (i) The rate quoted shall be deemed to include for necessary T&P, minor spares like nuts, bolts, washers, gasket, insulation tape, lugs, compound etc. to put in to the HT anels in serviceable condition, testing and commissioning all as specified and as directed by the Engineer-in-Charge. (ii) Major spares like CTs, PTs, IDMT relays, ammeters, voltmeters, indicator lamps, control wiring, rotary/selector & toggle switches etc shall be measured and paid separately under relevant items of Schedule 'A' item No. 75. However the rate quoted shall be deemed to include of fixing/ replacement and taking down old unsv one of item no 75 materials

-

-

-

... More
Supply only spare parts for VCB

-

-

-

... More
(i) Opening/Closing push button Assly

2

10

-

... More
(ii) Spring charging motor and Gear Assly.

1

10

-

... More
(iii) Limit Switch Assly including connected control wiring etc

2

10

-

... More
(iv) TNC Switch

2

10

-

... More
(v) Closing Coil

2

10

-

... More
(vi) Auxiliary Switch with link

2

10

-

... More
(vii) Tripping Coil

2

10

-

... More
(viii) Thermostat

2

10

-

... More
(ix) Spring return latch Assy

2

10

-

... More
(x) Vacuum interrupter Assy

2

10

-

... More
(xi) Digital ammeter with built in selector switch

2

10

-

... More
(xii) Shrounds for spout Insulator

2

10

-

... More
(xiii) Strip heater 230V, 80 Watt

2

10

-

... More
(xiv) Digital Voltmeter with built in selector switch

2

10

-

... More
(xv) Indicating Lamps LED Type

2

10

-

... More
(xvi) Support insulator

2

10

-

... More
(xvii) Fixed contact block 400 Amp

2

10

-

... More
(xviii) Moving contact block 400Amp

2

10

-

... More
Healthiness test of whole HT 11 KV installation such as VCB by injecting artifical HT supply complete all as directed

2

10

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.