Military Engineer Services Tender

... More
For getting the details of etenders, if you are looking for information about them from the cumbersome government websites but are tired of doing so, Bidassist comes up with a one stop solution. It collates every Eproc telangana tender on Bidassist. One can approach it for the bidding process, registration process, etc., are explained below.

Military Engineer Services - MES Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date17 May 2025
Closing Soon7 Jun 2025
Tender Amount₹ 46,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Removing excavated material exc. 50 m & n.exc 250 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.

2

-

-

... More
M & L PCC (1:4:8) type D2 (using 40mm graded stone aggregate) as in foundations filling and mass concrete complete all as specified and directed.

2

-

-

... More
M&L Providing RCC M-25 (Design mix) (using 20 mm graded stone aggregate) as in beams, cantilevers bressummers lintels over 1.5 m span,etc complete all as specified and directed.

5.1

-

-

... More
M & L Providing RCC M-25 (Design mix) (using 20 mm graded stone aggregate) as in Slabs supported on walls, beams and columns complete all as specified and directed.

6

-

-

... More
M & L Providing RCC M-25 (Design mix) (using 20 mm graded stone aggregate) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.

5.2

-

-

... More
M & L Providing RCC M-25 (Design mix) (using 20 mm graded stone aggregate) as in columns, pillars, piers, posts and struts complete all as specified and directed.

3

-

-

... More
Use and waste of Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter finished rough surfaces complete all as specified and directed.

25.5

-

-

... More
Use and waste of Formwork to soffits of roof slabs, floor slabs, landings and similar work not exceeding 200mm thick finished rough surfaces complete all as specified and directed.

42.5

-

-

... More
Use and waste of Form work to sides and soffits of floor or roof beams, beam haunching, lintel etc rough finished surfaces of concrete flat surfaces complete all as specified and directed.

25.8

-

-

... More
Use and waste of Formwork to sides of pillars, posts, struts, piers, columns and stanchions finished rough surfaces all as specified and directed.

25

-

-

... More
M&L Providing precast RCC (1:2:4) type B1 (using 20mmgraded stone aggregate) as in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain face set in CM (1:4) complete all as specified and as directed.

0.5

-

-

... More
Demolition of brickwork or stone/boulder masonry, built in cement mortar with all quoins, arches, pillars, etc but excluding ashlar facings, dressed stone work and precast concrete articles including disposal of the rubbish out off the premises complete all as specified and as directed.

4

-

-

... More
M & L Brick work with using old size flyash bricks straight or curved on plane exc 6m mean radius built in CM (1:6) complete all as specified and directed.

13.2

-

-

... More
M & L Half brick work with using old size flyash bricks , straight or curved on plan exc 6.0 m mean raduis and built in CM (1:4) as in partition walls complete all as specified and directed.

10

-

-

... More
M & L Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.

2100

-

-

... More
All as per Item No.18 above, but 6 mm to 8 mm dia complete all as specified and directed.

357

-

-

... More
All as per Item No.18 above, but 5 mm dia and over upto and including 10 mm dia in stirrups, spacers and binders, complete all as specified and directed.

30

-

-

... More
Dismantling of asbestos cement (corrugated semi corrugated etc.) sheet in roof covering/ fibre sheets etc complete all as specified and directed.

485

-

-

... More
Dismantling timber Scantling framed work in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section complete all as specified and as directed.

50

-

-

... More
Dismantling timber Scantling framed work 40 sqcm and over in section, in any position complete all as specified and as directed.

0.15

-

-

... More
S&F Second class hardwood clean sawn timber scantling as in purlins, trusses etc framed work complete all as specified and as directed

0.1

-

-

... More
Fixing only second class hardwood clean sawn timber scantling as in purlins, trusses etc framed work complete all as specified and as directed

0.05

-

-

... More
S&F Pre-painted galvalume aluminium zinc coating galvanised based corrugaed steel sheet 0.50mm thick, AZ-150 of approved colour sheet having tensile strength of 550 Mpa as roof covering/cladding to wall fixed with self tapping (SD) screws complete all as specified and as directed

458

-

-

... More
S&F Pre-painted galvalume aluminium zinc coating galvanised based profiled/plain steel sheet 0.50mm thick, AZ-150 of approved colour sheet having tensile strength of 550 Mpa as ridge, gutters fixed with self tapping (SD) screws complete all as specified and as directed

20

-

-

... More
M&L Providing PCC (1:2:4) type B1 (using 20 mm graded stone aggregate) as in bed block, coping, roof kerbs, bands filling in hollow portion of chowkats, etc including necessary form work complete all as specified and as directed

4.3

-

-

... More
S&F Rolled mild steel sections of Fe 410-W (Gde E-250) quality “A” frame work as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates complete all as specified and as directed

2110

-

-

... More
S&F Hand rails, half rounded or other stock section or core for wooden hand rail straight portion, drilled and counter sunk for balusters, nosing to steps including embeding in concrete and screwing etc wind ties for roof including securing bolts, posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc, flat iron fillets (for securing wire mesh etc) including all necessary drilling or riveting etc and similar work confirming to Fe-410-0 of Fe-310-0 of Gde E-165 complete all as specified and as directed

550

-

-

... More
Dismantling wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards / slabs / blankets any thickness including cover fillets etc complete all as specified and directed.

175

-

-

... More
S & F E Grid suspended false ceiling grid system of size 600 x 600mm with main runner 39x29.7x0.60mm cross tee 29x24.7x0.60mm and wall angle 22.2x22.2x0.50mm ceiling suspended with 2 to 2.5 mm dia GI wire hanger fixed to purlin / truss etc complete (Main runner, cross tee, wall angle of MS galvanised with PPCGS) over the grid providing 4mm thick HPSC pre primed self designer texture non asbestos fibre cement building board fixed to frames etc complete all as specified and and as directed

175

-

-

... More
Taking down chowkats or frames with shutters (without taking off shutters from frames) of size exceeding 1.5 sqm and not exc 4.00 sqm each complete all as specified and as directed

5

-

-

... More
Taking down chowkats or frames with shutters (without taking off shutters from frames) of size not exceeding 1.5 sqm each complete all as specified and as directed

115

-

-

... More
Taking down shutters of any description exc 1 Sqm but not exc 2 Sqm each all as specified and as directed

10

-

-

... More
M&L Cutting holes in brick wall built in cement mortor for inserting hold fast and making good the disturbed portion in CM (1:3) depth of embeded portion exc half brick & n.exc one brick complete all as specified and directed.

20

-

-

... More
S & F 2nd class hard wood plain, solid, straight chowkats and frames, wrought, framed, rebated on the solid rounded or chambered, put together with glue pinned at joints complete all as specified and directed.

0.15

-

-

... More
S&F 125 x 60 mm pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as specified and directed.

11

-

-

... More
M&L Treating small articles such as hold fasts, ends of posts, backs of chowkats etc area n.exc 0.10Sqm each with coal tar black paint complete all as specified and as directed.

0.2

-

-

... More
M&L Preparation of wood surface, treating the back of chowkhat, end of post etc with coal tar black paint area tarred exceeding 0.1 Sqm but not exc 0.5 sqm each all as specified and as directed

0.05

-

-

... More
S & F 35 mm 2nd class hard wood factory made plain framed panelled shutters (any number of panel) with panels of timber flat on both sides(feather edged) or of veneered particle board medium density wood particle board with commercial veneering on both faces. complete all as specified and directed.

23.6

-

-

... More
S & F 35 mm 2nd class hard wood factory made glazed and skelton shutters, open rebated and prepared to receive glass, gauge etc (without sash bars) edge of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc size of member of shutter as specified in SSR Part-I section 8 clause 8.24(a) etc complete all as specified and directed.

8

-

-

... More
S&F 100 mm size butt hinges extruded aluminium alloy with galvanised mild steel hinge pin, anodised, type C-21 complete all as specified and as directed

30

-

-

... More
S & F 100 mm size MS Butt hinges (medium weight) cold rolled complete all as specified and as directed

6

-

-

... More
S&F 150 mm length aluminium anodised barrel tower bolt of extruded section with bright bolt complete all as specified and as directed

40

-

-

... More
S & F 150 mm long aluminium alloy handles, fabricated type anodised complete all as specified and directed.

40

-

-

... More
S & F Mild steel sliding bolt 300 mm long plate type stove enameled black with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fix complete all as specified and as directed.

7

-

-

... More
M&L 4 mm thick sheet glass, ordinary quality and glazing with oil putty in squares not exceeding 0.5 Sqm in each pane,complete all as specified and as directed.

2.84

-

-

... More
S&F Stainless steel wire cloth.0.36mm nominal dia of wire and average width of aperture1.40mm and fixed withstainless steel wire staples complete all as specified and as directed

7

-

-

... More
S&F Steel windows (fly proof and glazed shutter) made with galvanised steel colour coated/ powder coated ( Base steel as per IS 513 'D', galvanised as per IS 277 with zinc of 120gm/sqm) with total coating thickness of 0.60mm. ( outside for glazing and inside gauged shutter) Sections for frame should be of 72mmx55mm, section for mullian should be 72mm x 50mm section for shutter frame should be 47mmx 20mm,and section for fixing glass bead should be 12mm x 12mm and section for fly mesh shutter frame should be 40mm x 20mm mesh fixing should be of 18mm x 0.6mm. Stainless steel wire mesh of 0.45mm dia and ave width of aperture 1.4mm shall be used for fly proofing . 4mm thick plain sheet glass to be used for glazing of glazed shutters,etc complete all as specified and directed.

173

-

-

... More
Dismantling Stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar complete all as specified and as directed.

13.28

-

-

... More
M&L 25 mm thick granite tiles (of any size) machine cut, jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone duly grinding and polishing laid over and including 15mm thick CM (1:4) screed bed as in steps, jambs, pillars, window cills, cooking platforms and like complete all as specified and as directed

53

-

-

... More
Rounding of / moulding to edges (half round) of stone of any description including rubbing and polishing (Granite finish), complete all as specified.

297

-

-

... More
M&L Machine cut kota stone flooring 20-25mm thick over cement scredd base laid and jointed with gray cement slurry mixed with pigment to match the shade of the slab inclduing rubbing and polishign complete all as specified and as directed.

72

-

-

... More
M&L Machine cut kota stone as in skirting / dado 20-25mm thick over cement plster of 10mm thick base laid and jointed with gray cement slurry mixed with pigment to match the shade of the slab inclduing rubbing and polishign complete all as specified and as directed.

7.2

-

-

... More
Demolition of PCC of any description and in any position not otherwise specifically provided for(un-rainforcement) and removal of rubbish/ demolished materials out of MD land complete all as specified and directed.

7.5

-

-

... More
M&L 75 mm thick PCC (1:3:6) type C2 (using 40mm graded stone aggregate) in plinth protection laid in alternative bays finished even and smooth without using extra cement including making 10 mm wide grooves to full depth at 3 m interval and at every change of direction and filling the grooves with mixture of bitumen and sand mixed in the ratio of 1:3 by weight and top 10 mm depth sealed with sealing compound grade ‘A’ complete all as complete all as specified and as directed

100.7

-

-

... More
Dismantling floor hearth or wall tiling including cement mortar bedding ( but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.

356.5

-

-

... More
M&L Non skid coloured ceramic tiles of size exceeding .0.06 square metre but not exceeding 0.11 square metre of 7 to 8mm thick set and jointed in neat cement slurry and pointed in coloured cement to match, laid over and including screed bed of 15 mm thick in CM (1:6) complete all as specified and as directed.

22.5

-

-

... More
M & L Non - skid Ceramic tiles 7 to 8 mm thick coloured area of each tile exceeding 0.18 sqm but not exc 0.38 sqm as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in CM (1:4) complete all as specified and directed.

25.4

-

-

... More
M & L Non - skid Ceramic tiles 7 to 8 mm thick coloured area of each tile exceeding 0.18 sqm but not exc 0.38 sqm as in skirting/dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the tiles over and including backing coat of 10 mm thick CM (1:4) complete all as specified and directed.

3.4

-

-

... More
M&L Glazed ceramic coloured wall tiles of approved colour of size 350x 250x 7/ 450x300x7 mm thick on vertical surfaces as in dado/wall set and jointed in neat cement slurry and pointed with white or coloured cement to match over and including 10 mm thick backing coat of CM (1:4) complete all as specified and as directed

159

-

-

... More
M&L Vitrified ceramic tiles 10mm (light shade of square/ rectangular) polished, area of each tiles not exc 0.36 sqm in floors etc,.set and jointed in neat cement slurry and pointed in white or coloured cement to match etc, complete all as specified and directed.

150

-

-

... More
Taking down cement plaster of any description and thickness on brick walls including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed.

200

-

-

... More
M&L Rendering 15 mm thick in two coats, 10 mm thick in CM (1:6) and 5 mm thick in CM (1:4) mixed with integral water proofing compound as per manufacturers instructions, on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed. Note: Water proofing compound shall be measured and paid separately.

86

-

-

... More
M&L Rendering 15 mm thick CM (1:6) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed.

100

-

-

... More
M&L Rendering 12 mm thick CM (1:4) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed.

90

-

-

... More
M&L Rendering 10 mm thick CM (1:6) on other than fair faces of brick surfaces finished even and smooth without using extra cement.complete all as specified and as directed.

72

-

-

... More
M & L Rendering 5 mm thick CM (1:3) on concrete surfaces such as ceiling or soffits of chhajas etc; finished even and smooth without using extra cement complete all as specified and as directed.

35

-

-

... More
Supply only water proofing compound of ISI marked complete all as specified and as directed.

23

-

-

... More
M&L Preparation of newly plastered surfaces of walls and applying three coats of white wash complete all as specified and as directed.

91

-

-

... More
M & L Preparing newly plastered ceiling surfaces and applying three coats of white wash complete all as specified and as directed.

10

-

-

... More
M & L Preparing the old plastered or unplastered decorated surfaces of walls and applying two coats of white wash complete all as specified and as directed.

50

-

-

... More
M & L Preparing old plastered ceiling surfaces and applying two coats of white wash complete all as specified and as directed.

110

-

-

... More
M&L Preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of primer complete all as specified and as directed.

186

-

-

... More
M & L Preparing old decorative surfaces of walls, by washing, rubbing down, stopping and applying two coats of cement base paint of any colour complete all as specified and as directed.

450

-

-

... More
M & L Preparing newly plasterd wall surfaces of walls applying two coats of oil bound distemper (oil emulsion) over a coat of primer over and including a coat of 3mm thick birla care wall putty in two layers complete all as specified and as directed.

70

-

-

... More
M&L Complete removal of existing treatment on wall surfaces and applying two coats of oil bound distemper (oil emulsion) over a coat of primer over and including a coat of 3mm thick birla care wall putty in two layers complete all as specified and as directed.

330

-

-

... More
M & L Preparation of new or previously untreted steel or iron surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.

144.3

-

-

... More
M & L Preparation of newly wood or wood based surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of prink primer etc completed all as specified and directed.

80.78

-

-

... More
Taking up or down steel tubing and connection, removing clear off site after credit for the same is recovered by the dept., bore of pipe 15mm complete all as specified and directed.

20

-

-

... More
Taking up or down steel tubing and connection, removing clear off site after credit for the same is recovered by the dept., bore of pipe 20mm complete all as specified and directed.

20

-

-

... More
Taking up or down steel tubing and connection, removing clear off site after credit for the same is recovered by the dept., bore of pipe 25mm complete all as specified and directed.

20

-

-

... More
S&F CPVC pipes, SDR 11, 20 mm outer dia of pressure rating 6kgf/sqcm conforming to IS-15778 with all CPVC fittings with such as brass elbow ,Tee, bends, unions ,sockets , male and femaleThreaded Adoptor and end pieces etc to receive fittings and fixed with solvents fixed to walls / ceiling with all clamps in Shafts/ducts with all necessary scaffolding to fix the pipes and testing the joints under prescribed pressure etc complete all as specified and as directed.

15

-

-

... More
S & F 15 mm dia GI tubes (medium grade) ISI marked, galvanised with all fittings fixed to walls and ceilings or laid in floors complete all as specified and directed.

5

-

-

... More
S & F 20 mm dia GI tubes (medium grade) ISI marked, galvanised with all fittings fixed to walls and ceilings or laid in floors complete all as specified and directed.

20

-

-

... More
S & F 25 mm dia GI tubes (medium grade) ISI marked, galvanised with all fittings fixed to walls and ceilings or laid in floors complete all as specified and directed.

20

-

-

... More
S&F in repair 25 mm dia gun metal globe or gate valves with iron wheel head , screwed both ends for iron pipe & fixed complete all as specified and directed.

2

-

-

... More
S&F 20mm dia gun meteal,globe or gate valves, with iron wheel head screwed both ends for iron pipe and fixed complete all as specified and directed.

2

-

-

... More
S&F in repairs 1000 litres capacity rotational moulded polyethylene water storage tank of triple layer type(cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I complete all as specified and as directed

1

-

-

... More
S&F in repairs vitreous china wash basin, white, flat back, size 580mm X 450mm including CI brackets, 32mm dia brass chromium plated waste fittings with long screwed shanks and fly nuts flanged end bedded in red lead cement and other end fixed with & including cutting for & pinning in end of brackets and 15mm bore pillar tap, cast copper alloy fancy type chromium plated, screwed down high pressure complete all as specified and as directed.

2

-

-

... More
S&F in repairs 15 mm bore Pillar taps, fancy type, chromium plated, screwed down, high pressure, with or without lettered ‘Hot' or ‘Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and as directed.

2

-

-

... More
S&F in repairs stainless steel sink overall size 495mmx420mm bowl size 410mmx330mmx160mm made out of stainless steel 1 mm thick for kitchen with plugs, washers and waste pipe including bedding in cement mortar to dwarf wall, CI brackets and connecting to union / pipe complete all as specified and as directed Make : Nirali, Bule star ISI marked..

5

-

-

... More
S&F in repairs 15mm bore CP bib tap fancy type with crutch or butterfly handle, screwed for iron pipe or for unions and fixed complete all as specified and directed.

10

-

-

... More
S&F in repairs 32 mm dia waste fittings, brass chromium plated for wash basins with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed complete all as specified and as directed

7

-

-

... More
Dismantling / taking down PVC/ Cast iron soil /waste pipes 100 mm / 75mm bore including all fittings like bends etc complete all as specified and directed

20

-

-

... More
S&F PVC (SWR) Nahani /Floor trap, 75 mm dia of out let, plain with grating including jointing to waste pipe with solvent and cement concrete type B1 (1:2:4) & including removing old trap and fixing of stainless steel grating in ground shape etc complete all as specified and as directed.

4

-

-

... More
S&F 75 mm bore PVC (SWR) pipe single socketed (ISI Marked) any length with rubber ring joints , complete fittings etc fixed to wall fixed with MS clamps 8mm dia with two nuts wall nails etc including all fittings complete all as specifed and directed.

10

-

-

... More
S&F 110 mm bore PVC (SWR) pipe single socketed(ISI Marked) any length with rubber ring joints , complete fittings etc fixed to wall fixed with MS clamps 8mm dia with two nuts wall nails etc including all fittings complete all as specifed and directed.

10

-

-

... More
Taking down existing unserviceable point wiring of any description/type/ size of light/fan/tube/power/two way/bell etc on TW batten/conduit including removal of batten / conduit / gutties / wooden boards / switches / sockets / regulators/ light fittings etc and removal of unserviceable material out of site and making good the disturbed surfaces of wall/ceiling so as to match with the existing finishes complete all as specifed and directed.

87

-

-

... More
Taking down old unservicieble existing submain wiring of any size and type complete all as specifed and directed.

90

-

-

... More
Taking down old unservicieble existing DB's any size and type complete all as specifed and directed.

3

-

-

... More
M&L Point wiring complete with stranded copper conductor cables in surface non-metallic PVC conduit 1.5 Sqmm (nominal area) PVC insulated unsheathed cable up to 1100 V grade FRLSH conforming to IS - 694 multistranded drawn including conduit with new sunk type pressed steel terminal boxes suitable for MODULAR switches including fixing/grouting sunken/ surface as per site requirement covered with suitable modular white cover plate for suitable size for mounting of MODULAR switches, regulators and drawing continuous earth wire with one run of 1.5 Sqmm (nominal area) PVC insulated unsheathed cable up to 1100 V grade FRLSH conforming to IS - 694 multistranded copper conductor as earth wire and connecting to common earth dolly for one light point controlled by one, one way switch 5 amps, SP and making good the disturbed wall surfaces to match with the existing surfaces complete all as specified and as directed. Note: 1. Rate of Moduler Inner and outer plate and modular metal box are inclusive. 2. Rate for Cutting chasses measured and paid seperately

54

-

-

... More
All as per Item No.103 above,but one Ceiling Fan / exhaust fan point controlled by one, one way switch and regulator

8

-

-

... More
All as per Item No.103 above,but one 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board .

8

-

-

... More
All as per Item No.103 above,but one 3 point 5 Amps switch socket outlet point controlled by one switch on the same board.

7

-

-

... More
All as per Item No.103 above,but using 2.5 Sqmm single core FRLSH copper conductor cable of multistranded PVC insulated unsheathed 1100 Volts grade for 3 Pin 15 Amps switch socket combination point on independent board including running of 2.5 Sq mm FRLSH copper conductor PVC insulated cable as earth continuity conductor.

15

-

-

... More
S&F Modular switch 1 way 6 A, 1 Module capacity 230 volts complete all as specified and as directed.

77

-

-

... More
S&F Switch Modular 1 way 16 Amps, 1 Module, 230 Volts complete all as specified and as directed.

15

-

-

... More
S&F Modular socket 5 pin 6 amps 2 Module, 230 Volts complete all as specified and directed.

15

-

-

... More
S&F Modular socket 6 pin 6/16 amps 2 Module, 230 Volts complete all as specified and as directed.

15

-

-

... More
S&F Fan regulator 5 stepped type 2 Module suitable for compatibility ceiling fans complete all as specified and as directed.

6

-

-

... More
S & F Lamp holder insulated body surface bakelite with back plate suitable for angle / batten fittings fixed with wooden round blocks inlcuding 9W LED bulb complete all as specified and as directed.

6

-

-

... More
S&F in replacement of 20 W light fitting, wall mounted LED batten with extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver, 230 volts, bipin holders, diffused type, connector block internally prewired etc with 2 Nos PVC round blocks for mounting arrangements including all accessories with new 3 core multi stranded copper conductor of size 23/0.193 from ceiling rose to fitting and including LED Tube 20W complete all as specified and as directed.

31

-

-

... More
S & F LED light fitting 1x10W bulk head luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.

3

-

-

... More
S&F in replacement of 35 watts LED Security Light fitting complete with Bracket made out GI pipe med grade 25mm of L Shape 1.5 Mtr long including clamps and nuts botls etc, complete all as specified and as directed.

4

-

-

... More
S&F in replacement LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete.all as specified and as directed.

10

-

-

... More
S&F in replacement ceiling rose three terminal surface bakelite type AC 50 Hz 230 volts of size 65 x 50 mm ccomplete all as specified and as directed.

56

-

-

... More
S&F in replacement sheet metal enclosure MCB DB SPN 8 way with 200 amps rated bus bar 240 volts double door with magnetic locking system complete all as specified and as directed.

2

-

-

... More
S&F in replacement sheet metal enclosure MCB DB SPN 4 way with 200 amps rated bus bar 240 volts double door with magnetic locking system complete all as specified and as directed.

1

-

-

... More
S&F MCB, SP 6-32 Amps, 240 volts of rupturing capacity 10 KA, 'C' series complete all as specified and as directed.

14

-

-

... More
S&F MCB, SP 40 Amps, 240 volts of rupturing capacity 10 KA, 'C' series complete all as specified and as directed.

12

-

-

... More
S & F MCB SPN 32 Amps 240 volts,'C' series complete all as specified and as directed.

1

-

-

... More
S & F MCB SPN 40 Amps 240 volts 'C' series complete all as specified and as directed.

1

-

-

... More
S & F MCB SPN 63 Amps 240 volts 'C' series complete all as specified and as directed.

1

-

-

... More
S & F in repair VTPN DB 4 Way suitable for flush mounting with 250A copper bus bar for each face, With 2 Neutral bar, 2 Earthbar and Cable ties for Cable management,Fully insulated busbar & shrouded Neutral bars, Improved Pan assembly for ease of installation, Prefitted masking sheet,Reversible Door for IP 43 & IP 54 DB's with provision for DPX³ 100/160 MCCB as incomer and SP MCB all as specified SP/TP MCB's as outgoingfitted with Bus Bars, Neutral Links, Blanking Plates (without MCCB) G-FRAME MCCB INCOMER DB (Busbar Rating - 160 A) complete all as specified and as directed. Make: Legrand Cat Part No 5077 40 or equivalent model in Havells/ L&T

1

-

-

... More
S & F in repairs MCCB 100A 16KA with Sheet metal enclosures complete all as specified and as directed.. Make -Legrand Cat No-4200 15 or equivalent model in Havells/ L&T

1

-

-

... More
M & L Submain wiring with two single core 2.5 sq mm FRLS PVC insulated copper conductor multistranded 1100 Volts grade drawn through and including rigid PVC conduit and concealed conduit accessories of suitable dia medium grade including running up of one runs of 2.5 sq mm FRLS copper conductor multistranded PVC insulated cable as earth continuity conductor along the wiring and connected to the common earth dolly complete including removing the existing unserviceable sub main wiring and making good the disturbed surface to match with the existing all as specified. Note:- Three runs of 2.5 sqmm cable, and one run of conduit shall be measured and paid as one unit length.

25

-

-

... More
M & L Submain wiring with two single core 6 Sq mm FRLS PVC insulated copper conductor multistranded 1100 Volts grade drawn through and including rigid PVC conduit and concealed conduit accessories of suitable dia medium grade including running up of one runs of 6 Sq mm FRLS copper conductor multistranded PVC insulated cable as earth continuity conductor along the wiring and connected to the common earth dolly complete including removing the existing unserviceable sub main wiring and making good the disturbed surface to match with the existing all as specified. Note:-Three runs of 6 sqmm cable, and one run of conduit shall be measured and paid as one unit length.

135

-

-

... More
M&L Earthing with galvanized mild steel earth plate electrode 60 centimetre x 60 centimetre x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below ground level, the top edge of the earth plate at a depth of not less than 1.5 metres below ground level connected to galvanized iron earth wire of 4 mm dia by means of bolts, nuts and washers made out of GI / steel earth wire protected by GI light grade pipe 15 mm bore, 20mm dia light grade galvanised iron pipe with funnel wire mesh for watering and connecting to main switch board / control board all s shown in electrical plate of SSR Pt - I connected to earthing test point and including testing on completion complete all as specified and as directed. Note: The unit rate shall also include for excavation, earth work in hard/dense soil, plain cement concrete 1:3:6 type C1 by using 20 mm graded aggregate in pit, 50 mm thick reinforced cement concrete 1:2:4 type B1 using 20 mm graded aggregate cover duly reinforced with 8 mm dia TMT bars @ 100mm centre to centre both ways, galvanised iron funnel with watering pipe, wire mesh,etc

3

-

-

... More
Disconnecting and removing ceiling/exhaust fan of any capactiy any height from electrical connection bringing down, dismantling, cleaning internally and externally thoroughly examine replacement of split pins, cotter pins and check nuts etc overhauling, lubricating with approved lubricants, reassembling, including replacement of wornout/defective parts, refixing in original position including minor repairs for the smooth functioning and provision of new flexible wire of size 23/0.0076 multistranded copper conductor cable from ceiling rose to fan complete all as specified and as directed. Note:- (1) Necessary repairs/ replacement of unserviceable parts shall be measured and paid seperately. (2)Labour element for replacing of u/s parts deemed to be included in rate quoted.

8

-

-

... More
M&L Rewinding of the ceiling/exhaust fan complete with equivalent new super enamelled copper wire of existing gauge and weight as per manufacturer's design and instructions including varnishing of ceiling fan of any make and any sweep including taking out burnt copper wire complete all as specified and as directed.

8

-

-

... More
S&F in repairs of Ball bearing/Brass bush of Ceiling Fan/Exhaust Fan complete all as specified and as directed.

8

-

-

... More
S&F in repairs of Capacitor Ceiling Fan/Exhaust Fan complete all as specified and as directed.

8

-

-

... More
M&L Painting of ceiling fans 48”/56” size complete at site, with super synthetic enamel paint by spraying incl filling cavities with filler, one coat after cleaning all dust etc complete,all as specified and as directed by Engr-in-Charge.

8

-

-

... More
S&F in replacement of metallic louvers mounted suitable for exhaust fan of 300 to 450 mm on wall all as specified and as directed by Engr-in-charge

2

-

-

... More
M & L Cutting chases, pining to making good to facing where ever required and pointing in cement motor 1:3 to ends or edges of endings, steps, cills etc and cutting chases for concealed wiring making good and cutting not exceeding10 cm grith complete all as specified and as directed.

699

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.