For getting the details of etenders, if you are looking for information about them from the cumbersome government websites but are tired of doing so, Bidassist comes up with a one stop solution. It collates every Eproc telangana tender on Bidassist. One can approach it for the bidding process, registration process, etc., are explained below.
Costs
EMD
₹ 7,331Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
580666Tender No
10/2024-25, Dt:10.03.2025Tender Authority
Irrigation And CAD Department ViewPurchaser Address
-Website
http://https://irrigation.telangana.gov.in/icad/home
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Emergency Repair estimate for 400KVA Transformer in V. Venkatayapalem LI Scheme located on 21st MBC;Replacing old and unserviceable gasket of top cover plate of transformer having following capacity up to 500 KVA(Rate adopted for 400 kva T/f)
1
1562
1562
... More
Emergency Repair estimate for 400KVA Transformer in V. Venkatayapalem LI Scheme located on 21st MBC;Supply of 11 KV Hand gloves
2
1136
2272
... More
Emergency Repair estimate for 400KVA Transformer in V. Venkatayapalem LI Scheme located on 21st MBC;Supply and erection of approved make 11 KVoutdoor type gang opeRated Air Break switch of400 A capacity with 3 post pin type insulatorper phase, mounted in Horizantal / Vertical position with necessary channels on crossarms with adequate length of 'C' class GI pipefor operating handle provided with Lock & Key at suitable height from ground level withnecessary clamps. (replacing the damaged AB switch)
1
12463
12464
... More
Emergency Repair estimate for 400KVA Transformer in V. Venkatayapalem LI Scheme located on 21st MBC;Supply of Transformer oil tested as per IS-335 - 1972 for 400 kva T/F
500
168
84100
... More
Emergency Repair estimate for 400KVA Transformer in V. Venkatayapalem LI Scheme located on 21st MBC;Replacing old and unserviceable gasket of bushing for the following Transformer capacity up to 500 KVA L.T.(Rate adopted for 400 kva T/f)
1
2141
2142
... More
Emergency Repair estimate for 400KVA Transformer in V. Venkatayapalem LI Scheme located on 21st MBC;Fabrication, Assembling of transformer core with CRGO Material sheet (M4 or Better grade) only prime quality material having low loss and good grain properties coated with hot oil proof insulation, bolted together and to the frames firmly to prevent vibration or noise for 400 KVA transformers as per ISO design standards
490
650
318500
... More
Emergency Repair estimate for 400KVA Transformer in V. Venkatayapalem LI Scheme located on 21st MBC;Routine maintenance of transformer in operation covering insulation resistance oil, break down strength. Reconditioning / replacement of silicazel, cleaning of transformer and topping upto oil level if required (extra cost will be paid for oil). (Rate for replacement of breather with silica gel filling 400 kva T/f)
1
6510
6510
... More
Emergency Repair estimate for 400KVA Transformer in V. Venkatayapalem LI Scheme located on 21st MBC;Replacement the H.T. / L.T. burnt-out winding coils of distribution transformer including rewinding, varnishing and vacuuming etc., duly retaining the removed burnt winding coils by the Contractor / Firm for copper coils
280
926
259280
... More
Emergency Repair estimate for 400KVA Transformer in V. Venkatayapalem LI Scheme located on 21st MBC;Drying the repaired transformer with appropriate heat / air --upto 500KVA (Rate adopted for 400 kva T/f)
1
5908
5908
... More
Emergency Repair estimate for 400KVA Transformer in V. Venkatayapalem LI Scheme located on 21st MBC;Loading and Unloading of transformer from site to Workshop or vice versa----- upto 500 KVA. (Rate adopted for 400 kva T/f)
1
6328
6328
... More
Emergency Repair estimate for 400KVA Transformer in V. Venkatayapalem LI Scheme located on 21st MBC;Painting with 2 coats Zinchromate red oxide duly scraping existing paint followed by 2 coats of hammerton grey paint etc., complete. Up to500 KVA. (Rate adopted for 400 kva T/f)
1
4215
4215
... More
Emergency Repair estimate for 400KVA Transformer in V. Venkatayapalem LI Scheme located on 21st MBC;Replacing LT Bushings metal parts- for distribution Transformer by new one for 500 kva (Rate adopted for 400 kva T/f)
3
1834
5505
... More
Emergency Repair estimate for 400KVA Transformer in V. Venkatayapalem LI Scheme located on 21st MBC;Replacing HT Bushings metal parts- for distribution Transformer by new one. (Rate adopted for 400 kva T/f)
3
539
1619
... More
Emergency Repair estimate for 400KVA Transformer in V. Venkatayapalem LI Scheme located on 21st MBC;Replacing LT Bushings- for distribution Transformer by new one up to 500 KVA (Rate adopted for 400 kva T/f)
3
250
750
... More
Emergency Repair estimate for 400KVA Transformer in V. Venkatayapalem LI Scheme located on 21st MBC;Removing the existing transformer from the plinth / Pole and refixing the standby transformer of following capacity including connections etc.,up to 500 KVA (Rate adopted for 400 kva T/f)
1
9839
9839