Irrigation And CAD Department Tender

For getting the details of etenders, if you are looking for information about them from the cumbersome government websites but are tired of doing so, Bidassist comes up with a one stop solution. It collates every Eproc telangana tender on Bidassist. One can approach it for the bidding process, registration process, etc., are explained below.

Irrigation And CAD Department Tender

Works
Electrical Generators And Transformers
Electrical and Electronics
Opening Date11 Nov 2024
Closing Date18 Nov 2024
Tender Amount₹ 21,08,779 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Emergency Repairs to Electrical, Mechanical Equipment and Restoration of 400 KVA , 315 KVA Transfor;Supply and fixing of Non-Drive end cover for 125 HP motor -ABB make

1

45000

45000

... More
Emergency Repairs to Electrical, Mechanical Equipment and Restoration of 400 KVA , 315 KVA Transfor;Supply and fixing of cooling fan protection cover for 125 HP motor - ABB make

1

20000

20000

... More
Emergency Repairs to Electrical, Mechanical Equipment and Restoration of 400 KVA , 315 KVA Transfor;Painting to Sluice Valves, NRVs, Suction pipes, Delivery pipes and other metal surfaces in L13 L.I. Scheme

1

25000

25000

... More
Emergency Repairs to Electrical, Mechanical Equipment and Restoration of 400 KVA , 315 KVA Transfor;Internal Wiring inside the L13 Pumphouse with new wires etc.,

1

15000

15000

... More
Emergency Repairs to Electrical, Mechanical Equipment and Restoration of 400 KVA , 315 KVA Transfor;Supply of Coupler belts set (Fibre) with bolts, bushes to the work site for connecting 125 HP motor and pump shaft,. Including lathing, turning and erecting charges, etc. as directed by the Engineer in charge

2

22000

44000

... More
Emergency Repairs to Electrical, Mechanical Equipment and Restoration of 400 KVA , 315 KVA Transfor;Supply and Fixing/replacement of old existing Bearings No. (6316C3-1No., 6315C3 -1No.)suitable for 125 HP, 3Phase up to 1460 RPM of all types and make ABB motor, including labour charges all other incidental charges etc. complete.

3

40000

120000

... More
Emergency Repairs to Electrical, Mechanical Equipment and Restoration of 400 KVA , 315 KVA Transfor;Rewinding of Electric motor up to and including 125 HP, 3Phase up to 1460 RPM of all types and makes with copper wire including minor repairs, lubrication of ball bearings,bush bearings screws, assembling the motor, erection on base plate correct alignment of pump and motor, testing of motor for original speed, trial run at site , including labour charges, transportation charges of motor from scheme to workshop and vice verse and all other incidental charges etc., complete.

1

120000

120000

... More
Emergency Repairs to Electrical, Mechanical Equipment and Restoration of 400 KVA , 315 KVA Transfor;Complete dismantling, overhauling of WILO make 125 HP Pump set, with replacement of Bearings 2 No with impeller Rings and Impeller balancing, Neck rings as per Sample, Gland packing, Packing ropes, complete greasing, assembling the motor alignment with pump oil and trail run at site including labour charges as directed by the Engineer-in-Charge.

1

65000

65000

... More
Emergency Repairs to Electrical, Mechanical Equipment and Restoration of 400 KVA , 315 KVA Transfor;Complete dismantling, overhauling of WILO make 60 HP Pump set, with replacement of Bearings 2 No with impeller rings and Impeller balancing, Neck rings as per Sample, Gland packing, Packing ropes, complete greasing, assembling the motor alignment with pump oil and trail run at site including labour charges.

2

45000

90000

... More
Emergency Repairs to Electrical, Mechanical Equipment and Restoration of 400 KVA , 315 KVA Transfor;Complete dismantling, overhauling of 300mm to 500mm dia Non return valve replacement of warnout parts like shutter shaft gun metal bushers facing of shutter providing new bolts and nuts, collars, rubber packing and arresting leakages, repairs assembling of valve including cost of materials, labour charges transportation charges of valve from scheme to work shop,work shop to scheme and all other incidental charges etc.,complete.

2

13500

27000

... More
Emergency Repairs to Electrical, Mechanical Equipment and Restoration of 400 KVA , 315 KVA Transfor;Supply and fixing of Star and Delta L&T MNX 140 Power Contactor in panel board

3

26000

78000

... More
Emergency Repairs to Electrical, Mechanical Equipment and Restoration of 400 KVA , 315 KVA Transfor;Supply of wheel bearing Grease

30

340

10224

... More
Emergency Repairs to Electrical, Mechanical Equipment and Restoration of 400 KVA , 315 KVA Transfor;Supply and fixing of heavy duty long barrel alluminium lugs confirming to I.S specifications suitable for 240 Sq.mm cable etc complete with nuts,bolts and washers. Makes: DMI / Jainson / Dowels or equivalent make as approved by the department.

6

227

1363

... More
Emergency Repairs to Electrical, Mechanical Equipment and Restoration of 400 KVA , 315 KVA Transfor;Painting with 2 coats Zinchromate red oxide duly scraping existing paint followed by 2 coats of hammerton grey paint etc., complete upto 500KVA Transformer.

2

4215

8430

... More
Emergency Repairs to Electrical, Mechanical Equipment and Restoration of 400 KVA , 315 KVA Transfor;Replacing LT Bushing Metal parts for distribution Transformer upto 500 Kva by new one.

3

1834

5505

... More
Emergency Repairs to Electrical, Mechanical Equipment and Restoration of 400 KVA , 315 KVA Transfor;Replacing LT Bushing Metal parts for distribution Transformer of 315 Kva by new one.

3

704

2113

... More
Emergency Repairs to Electrical, Mechanical Equipment and Restoration of 400 KVA , 315 KVA Transfor;Replacing LT Bushing for distribution Transformer of 400 KVA by new one.

3

250

750

... More
Emergency Repairs to Electrical, Mechanical Equipment and Restoration of 400 KVA , 315 KVA Transfor;Replacing LT Bushing for distribution Transformer of 315 Kva by new one.

3

238

716

... More
Emergency Repairs to Electrical, Mechanical Equipment and Restoration of 400 KVA , 315 KVA Transfor;Replacing HT Bushing Metal parts for distribution of Transformer by new one.

3

539

1619

... More
Emergency Repairs to Electrical, Mechanical Equipment and Restoration of 400 KVA , 315 KVA Transfor;Replacing HT Bushing for distribution Transformer by new one.

3

499

1500

... More
Emergency Repairs to Electrical, Mechanical Equipment and Restoration of 400 KVA , 315 KVA Transfor;Replacing old and unserviceable gasket of bushing for upto 500 KVA Transformer capacity for LT.

3

2141

6425

... More
Emergency Repairs to Electrical, Mechanical Equipment and Restoration of 400 KVA , 315 KVA Transfor;Replacing old and unserviceable gasket of bushing for upto 315 Kva Transformer capacity for LT.

3

1045

3136

... More
Emergency Repairs to Electrical, Mechanical Equipment and Restoration of 400 KVA , 315 KVA Transfor;Replacing old and unserviceable gasket of bushing for upto 500 KVA Transformer capacity for HT.

3

829

2488

... More
Emergency Repairs to Electrical, Mechanical Equipment and Restoration of 400 KVA , 315 KVA Transfor;Replacing old and unserviceable gasket of bushing for upto 315Kva Transformer capacity for HT.

3

454

1364

... More
Emergency Repairs to Electrical, Mechanical Equipment and Restoration of 400 KVA , 315 KVA Transfor;Replacing old and unserviceable gasket of top cover plate of transformer having upto 500 KVA capacity

1

1562

1562

... More
Emergency Repairs to Electrical, Mechanical Equipment and Restoration of 400 KVA , 315 KVA Transfor;Replacing old and unserviceable gasket of top cover plate of transformer having upto 315 kva capacity

1

1113

1113

... More
Emergency Repairs to Electrical, Mechanical Equipment and Restoration of 400 KVA , 315 KVA Transfor;Testing of Insulation Resistance H.T. / LT copper / aluminium coils for Transformers

2

448

898

... More
Emergency Repairs to Electrical, Mechanical Equipment and Restoration of 400 KVA , 315 KVA Transfor;Testing of Transformer oil for dielectric breakdown strength.

2

891

1784

... More
Emergency Repairs to Electrical, Mechanical Equipment and Restoration of 400 KVA , 315 KVA Transfor;Filteration of transformer oil as per ISS specifications filters to die-electric strength above 40 KV at workshop

850

9

7735

... More
Emergency Repairs to Electrical, Mechanical Equipment and Restoration of 400 KVA , 315 KVA Transfor;Transformer oil tested as per IS-335 - 1972 (per Ltr)

850

168

142970

... More
Emergency Repairs to Electrical, Mechanical Equipment and Restoration of 400 KVA , 315 KVA Transfor;Drying the repaired transformer with appropriate heat / air for upto 500/1000 Kva Transformer.

1

5908

5908

... More
Emergency Repairs to Electrical, Mechanical Equipment and Restoration of 400 KVA , 315 KVA Transfor;Drying the repaired transformer with appropriate heat / air for upto 315 Kva Transformer.

1

4215

4215

... More
Emergency Repairs to Electrical, Mechanical Equipment and Restoration of 400 KVA , 315 KVA Transfor;Supply of new Copper winding wire for HT and LT coils for distribution transformer capacity of 315 KVA and 400 KVA

585

1503

879314

... More
Emergency Repairs to Electrical, Mechanical Equipment and Restoration of 400 KVA , 315 KVA Transfor;Loading and Unloading of transformer from site to Workshop or vice versa for upto 500 Kva Transformer

4

6328

25314

... More
Emergency Repairs to Electrical, Mechanical Equipment and Restoration of 400 KVA , 315 KVA Transfor;Supply and transportation of 43 / 45 W +/-10% (>=4500 Lumens) LED Street light Body made of high grade pressure die ? cast Aluminium alloy with corrosion resistant powder coat, having protective toughened glass cover, Less Glare, IP 66 (Silicon gasket ensures Optical & Electrical compartments are IP 66) protected, wide operating voltage range, P.F > 0.90, System having efficacy >100 lumens/watt, with Ingress protection IP66, Potted driver, Driver surge protection >10KV, THD<15%, CCT: 3000- 6500K as desired by the department and as per IS, CRI>70, Inbuilt Electrical protections like Over voltage, short circuit, Over load, Open Circuit, Miswiring, etc complete with BIS certification with 5 years warranty. The contractor must furnish the manufacturer warranty letter, LM 79 and LM 80 certificates. LUMINAIRE MAKE : PHILIPS / OSRAM / GE Venture / CROMPTON / BAJAJ / Wipro / Jaquar / Eveready / Halonix / Keselec / HAVELLS / POLYCAB / SURYA / SYSKA / Capart / Fortune Arrt / FIEM / Panasonic / Arraystorm / GM / Goldmedal LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA / OSRAM / SAMSUNG / LG LEDs.

6

3317

19906

... More
Emergency Repairs to Electrical, Mechanical Equipment and Restoration of 400 KVA , 315 KVA Transfor;Supply of 350A HRC Fuse Links.Makes : L & T / C & S / Standard / HPL /Havells / Siemens / Indo Asian.

6

465

2795

... More
Emergency Repairs to Electrical, Mechanical Equipment and Restoration of 400 KVA , 315 KVA Transfor;Supply and fixing of 32A TPN Switch Disconnector Fuse Unit Cubical type without fuses.Makes : LK (L&T )/ SCHNEIDER / C&S / ABB /SIEMENS/BCH

2

1630

3261

... More
Emergency Repairs to Electrical, Mechanical Equipment and Restoration of 400 KVA , 315 KVA Transfor;Supply & Fixing of D.O.L Starter 250V,Single phase, 50Hz. With SS enclouser comprising of contactor with bi-metalic relay with necessary push buttons, etc., complete suitable upto 7.5 HP.Makes: Siemens / LK (L&T) / BCH

2

3294

6590

... More
Emergency Repairs to Electrical, Mechanical Equipment and Restoration of 400 KVA , 315 KVA Transfor;Supply and erection of LED indication lamps on the existing panel board,including connections etc., complete.Makes : L&T / C&S / SALZAR / HPL MAKE.

12

187

2250

... More
Emergency Repairs to Electrical, Mechanical Equipment and Restoration of 400 KVA , 315 KVA Transfor;Supply and erection of 0-100 / 200 / 400 / 600 /1000 Digital Ammeter of size 96x96mm on existing panel board including connections etc., complete.MAKES : CONZERVE / ELMEASURE / L&T / SEIMEN

4

2755

11021

... More
Emergency Repairs to Electrical, Mechanical Equipment and Restoration of 400 KVA , 315 KVA Transfor;Supply and erection of 0-500V Digital Voltmeter on existing panel board including connections etc., complete.MAKES : CONZERVE / ELMEASURE / LK (L&T) / SEIMENS

2

2755

5510



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.