Irrigation And CAD Department Tender

... More
For getting the details of etenders, if you are looking for information about them from the cumbersome government websites but are tired of doing so, Bidassist comes up with a one stop solution. It collates every Eproc telangana tender on Bidassist. One can approach it for the bidding process, registration process, etc., are explained below.

Irrigation And CAD Department Tender

Works
Electrical Generators And Transformers
Electrical and Electronics
Opening Date11 Mar 2025
Closing Date14 Mar 2025
Tender Amount₹ 7,33,123 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Emergency Repair estimate for 400KVA Transformer in V. Venkatayapalem LI Scheme located on 21st MBC;Replacing old and unserviceable gasket of top cover plate of transformer having following capacity up to 500 KVA(Rate adopted for 400 kva T/f)

1

1562

1562

... More
Emergency Repair estimate for 400KVA Transformer in V. Venkatayapalem LI Scheme located on 21st MBC;Supply of 11 KV Hand gloves

2

1136

2272

... More
Emergency Repair estimate for 400KVA Transformer in V. Venkatayapalem LI Scheme located on 21st MBC;Supply and erection of approved make 11 KVoutdoor type gang opeRated Air Break switch of400 A capacity with 3 post pin type insulatorper phase, mounted in Horizantal / Vertical position with necessary channels on crossarms with adequate length of 'C' class GI pipefor operating handle provided with Lock & Key at suitable height from ground level withnecessary clamps. (replacing the damaged AB switch)

1

12463

12464

... More
Emergency Repair estimate for 400KVA Transformer in V. Venkatayapalem LI Scheme located on 21st MBC;Supply of Transformer oil tested as per IS-335 - 1972 for 400 kva T/F

500

168

84100

... More
Emergency Repair estimate for 400KVA Transformer in V. Venkatayapalem LI Scheme located on 21st MBC;Replacing old and unserviceable gasket of bushing for the following Transformer capacity up to 500 KVA L.T.(Rate adopted for 400 kva T/f)

1

2141

2142

... More
Emergency Repair estimate for 400KVA Transformer in V. Venkatayapalem LI Scheme located on 21st MBC;Fabrication, Assembling of transformer core with CRGO Material sheet (M4 or Better grade) only prime quality material having low loss and good grain properties coated with hot oil proof insulation, bolted together and to the frames firmly to prevent vibration or noise for 400 KVA transformers as per ISO design standards

490

650

318500

... More
Emergency Repair estimate for 400KVA Transformer in V. Venkatayapalem LI Scheme located on 21st MBC;Routine maintenance of transformer in operation covering insulation resistance oil, break down strength. Reconditioning / replacement of silicazel, cleaning of transformer and topping upto oil level if required (extra cost will be paid for oil). (Rate for replacement of breather with silica gel filling 400 kva T/f)

1

6510

6510

... More
Emergency Repair estimate for 400KVA Transformer in V. Venkatayapalem LI Scheme located on 21st MBC;Replacement the H.T. / L.T. burnt-out winding coils of distribution transformer including rewinding, varnishing and vacuuming etc., duly retaining the removed burnt winding coils by the Contractor / Firm for copper coils

280

926

259280

... More
Emergency Repair estimate for 400KVA Transformer in V. Venkatayapalem LI Scheme located on 21st MBC;Drying the repaired transformer with appropriate heat / air --upto 500KVA (Rate adopted for 400 kva T/f)

1

5908

5908

... More
Emergency Repair estimate for 400KVA Transformer in V. Venkatayapalem LI Scheme located on 21st MBC;Loading and Unloading of transformer from site to Workshop or vice versa----- upto 500 KVA. (Rate adopted for 400 kva T/f)

1

6328

6328

... More
Emergency Repair estimate for 400KVA Transformer in V. Venkatayapalem LI Scheme located on 21st MBC;Painting with 2 coats Zinchromate red oxide duly scraping existing paint followed by 2 coats of hammerton grey paint etc., complete. Up to500 KVA. (Rate adopted for 400 kva T/f)

1

4215

4215

... More
Emergency Repair estimate for 400KVA Transformer in V. Venkatayapalem LI Scheme located on 21st MBC;Replacing LT Bushings metal parts- for distribution Transformer by new one for 500 kva (Rate adopted for 400 kva T/f)

3

1834

5505

... More
Emergency Repair estimate for 400KVA Transformer in V. Venkatayapalem LI Scheme located on 21st MBC;Replacing HT Bushings metal parts- for distribution Transformer by new one. (Rate adopted for 400 kva T/f)

3

539

1619

... More
Emergency Repair estimate for 400KVA Transformer in V. Venkatayapalem LI Scheme located on 21st MBC;Replacing LT Bushings- for distribution Transformer by new one up to 500 KVA (Rate adopted for 400 kva T/f)

3

250

750

... More
Emergency Repair estimate for 400KVA Transformer in V. Venkatayapalem LI Scheme located on 21st MBC;Removing the existing transformer from the plinth / Pole and refixing the standby transformer of following capacity including connections etc.,up to 500 KVA (Rate adopted for 400 kva T/f)

1

9839

9839



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.