Indian Institute Of Technology Tender

For getting the details of etenders, if you are looking for information about them from the cumbersome government websites but are tired of doing so, Bidassist comes up with a one stop solution. It collates every Eproc telangana tender on Bidassist. One can approach it for the bidding process, registration process, etc., are explained below.

Indian Institute Of Technology - IIT Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date10 Dec 2024
Closing Date24 Dec 2024
Tender Amount₹ 1,40,20,618 
Notes
Download

Costs

Summary

Campus Development Project Of Iith, Sub Head Upgradation Of Water Pumping System In Sv 20 Station And Stp 01 For Domestic, Treated And Soft Water Supply

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Domestic Water Supply Duty of each pump suitable for:- No. of Pumps : 3 nos. (2 W + 1 S) Capacity : 31.1 m3/Hour of Each Pump Head : 80 Meters Motor Power: 11 KW Air Vessel/Pressure Tank : 1 Nos of Min. 200 Liters Cap. 16 barNote:-1 set consists of 3 nos. of pumps (2Working + 1Standby)

1

-

-

... More
Treated Water Supply Duty of each pump suitable for:- No. of Pumps : 3 nos. (2 W + 1 S) Capacity : 21.4 m3/Hour of Each Pump Head : 92 Meters Motor Power: 11 KW Air Vessel/Pressure Tank : 1 Nos of Min. 300 Liters Cap. 16 bar Note:-1 set consists of 3 nos. of pumps (2Working + 1Standby)

1

-

-

... More
Treated Water Supply Duty of each pump suitable for:- No. of Pumps : 3 nos. (2 W + 1 S) Capacity : 20 m3/Hour of Each Pump Head : 104 MetersMotor Power: 7.5 KW Air Vessel/Pressure Tank : 1 Nos of Min. 300 Liters Cap. 16 bar Note:-1 set consists of 3 nos. of pumps (2Working + 1Standby)

1

-

-

... More
Treated Water Supply Duty of each pump suitable for:- No. of Pumps : 2 nos. (1 W + 1 S) Capacity : 31.1 m3/Hour of Each Pump Head : 80 MetersMotor Power: 11 KW Air Vessel/Pressure Tank : 1 Nos of Min. 200 Liters Cap. 16 bar Note:-1 set consists of 1 nos. of pumps (1Working + 1Standby)

1

-

-

... More
Soft Water Supply Duty of each pump suitable for:- No. of Pumps : 2 nos. (1 W + 1 S) Capacity : 30 m3/Hour of Each Pump Head : 75 MetersMotor Power: 11 KW Air Vessel/Pressure Tank : 1 Nos of Min. 200 Liters Cap. 16 bar Note:-1 set consists of 2 nos. of pumps (1Working + 1Standby)

1

-

-

... More
Soft Water Supply Duty of each pump suitable for:- No. of Pumps : 2 nos. (1 W + 1 S) Capacity : 25 m3/Hour of Each Pump Head : 90 Meters Motor Power: 11 KW Air Vessel/Pressure Tank : 1 Nos of Min. 200 Liters Cap. 16 bar Note:-1 set consists of 2 nos. of pumps (1Working + 1Standby)

1

-

-

... More
SH-2: Panel,DB & Cables Design, fabrication, assembling, wiring, testing, supply, forwarding to site, unloading, shifting to location, inspection, installation, testing and commissioning of Floor standing/Wall Mounting LT Panel / Main distribution / sub-distribution panels fabricated out of 14 gauge CRCA sheet steel in cubicle formation, compartmentalized, free standing floor mounted (IP52), dust and vermin proof. 16 gauge CRCA sheet steel shall be used for non load bearing walls, 2.5mm for load bearing member. 3 mm thick cable gland plates. 2 No. earthing terminals shall be provided for all distrtibution panels. Lifting hooks shall also be provided in case of large panels. Approval shall be taken for each panel in the form of shop drawings before fabrication.

-

-

-

... More
Incomer: 400A 4P 50KA MCCB With +SPDRS+Extn. ROM, THERMAL with Aux. contacts i. MCCB ON, OFF & TRIP I/Lamps ii.Digital Metering with M/F Meter iii. R,Y,B Indication lamps Outgoing: 1. 100A 4P 36KA MCCB + SPDRS+ROM, THERMAL, with ON,OFF & Trip indication lamp 2.63A 4P MCBs x 4 no's 3. 32A 4P MCBs x 4 no's Metering: RYB Indication Lamps, ON/OFF Indication Lamps. Only Approved makes should be used in the LT Panel / Main distribution / sub-distribution panel.

1

-

-

... More
Supply installation, testing and commissioning of 160A MCCB with all required spreader links in existing LT panel with suitable rated bus links to connect from existing main BUS bas in LT panel to incomer of MCCB and suitable bus/cables fro MCCB O/G with terminal link with all accessories as required.

1

-

-

... More
Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.

-

-

-

... More
125 Amp, 36KA, FPMCCB

1

-

-

... More
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)

-

-

-

... More
4 way (4 + 12), Double door

1

-

-

... More
Supplying and fixing of 415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles and Amps rating in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

... More
Triple pole 63A

4

-

-

... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

... More
Single pole

3

-

-

... More
Triple pole

3

-

-

... More
Supply, loading, transportation, unloading at site, storage st site, shifting from storage place to site of following size of XLPE Insulated PVC Sheathed, FRLS, Aluminium Conductor armoured power cable of 1.1 KV grade conforming to IS 7098 amended upto date and as per specifications.

-

-

-

... More
3.5C X 35 Sqmm

25

-

-

... More
4C X 16 Sqmm

315

-

-

... More
4C X 185 Sqmm

90

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.

-

-

-

... More
Above 95 sq. mm and upto 185 sq. mm

60

-

-

... More
Laying and fixing of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1KV grade of following size on cable tray as required.

-

-

-

... More
Up to 35sqmm(clamped with 1mm thick saddle)

315

-

-

... More
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)

25

-

-

... More
Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)

30

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.

-

-

-

... More
150 mm width X 50 mm depth X 1.6 mm thickness

120

-

-

... More
Supply and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade as required.

-

-

-

... More
3½ X 185 sq. mm (57mm)

4

-

-

... More
3½ X 35 sq. mm (32mm)

2

-

-

... More
4 X 16 Sqmm (28mm)

16

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.