Indian Institute Of Chemical Technology Tender
For getting the details of etenders, if you are looking for information about them from the cumbersome government websites but are tired of doing so, Bidassist comes up with a one stop solution. It collates every Eproc telangana tender on Bidassist. One can approach it for the bidding process, registration process, etc., are explained below.
Costs
EMD
₹ 28,497Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_CSIR_184964_1Bid Award Id
ViewTender No
ESD/L-338/2023Tender Authority
Indian Institute Of Chemical Technology ViewPurchaser Address
-Website
http://csir.res.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
NIT of Renovation and waterproofing treatment of Chemical Engineering building at CSIR-IICT, Hyderabad.
BOQ Items
... More
15 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement: 6 fine sand)
56
-
-
... More
Providing and applying Cement mortar 1:6 (1 cement : 6 fine sand). In petty civil works as directed by Engineer incharge.
3
-
-
... More
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter Approved make as directed by Engineer inchrge.
240
-
-
... More
Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand :4 graded stone aggregate 20mm nominal size)
3
-
-
... More
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Bend 87.5° 110 mm bend approved make as directed by engineer incharge.
8
-
-
... More
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Shoe (Plain) 110 mm Shoe approved make as directed by engineer incharge.
8
-
-
... More
Cutting holes of required size in brick masonry wall for fixing of 110mm dia PVC RAIN WATER PIPES making good the same etc. complete as per direction of Engineer-in-charge.
8
-
-
... More
Removing the existing damaged water proofing treatment made out of APP membrane and top silver sheet disposing the obtained rubbish outside IICT premises to the approved muncipal ground including removal of waste materials lying on terrace and stacking them as directed with all leads and lifts etc. complete.
910
-
-
... More
Finishing walls with Acrylic Smooth exterior paint of required shade : Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface including necessary touch up with primer,putty scrabing etc.. where ever necessary complete. Asain make (Apex) or its Equivalent approved make
2193
-
-
... More
Demolishing brick work in cement motor all heights up to 3floors (sun shades) manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material outside IICT to the approved muncipal grounbds all lead as per direction of Engineer-in-charge
13
-
-
... More
12 mm cement plaster finished with a floating coat of neat cement of
mix : 1:4 (1 cement: 4 fine sand) to sunshades all heights up to 3 floors.
120
-
-
... More
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats
13
-
-
... More
Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete. With Aluminium U beading
4
-
-
... More
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) approved make as directed by engineer inchrge.
8
-
-
... More
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of luminium snap beading shall be paid in basic item): With float glass panes of 5 mm hickness (weight not less than 12.50 kg/sqm) approved make as directed by engineer inchrge.
2
-
-
... More
Dismantling doors M.S.Frames windows (steel ) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within IICT campus as directed including alround plastering the surface after removing of windows in cement motor 1;6 (1 Cement ; 6 Fine sand) size of the windows below 3.00sqm
10
-
-
... More
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron)
66
-
-
... More
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron) kg
43
-
-
... More
Providing and laying of APP (Atactic Polypropylene Polymer) modified prefabricated five layer 4 mm thick water proofing membrane, black finished reinforced with nonwoven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete.. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane. 1. cleaning the surface from all loose gravel,dirt and foreign materials which may impair the bond or demage the membrane. 2.Supply and apply of coat of bitumen 85/25 grade @ 500grms/sqm allow it to touch dry. 3. supply and apply of coat super silver (bitumen aluminum paint) 300grms/sqm over the membrane to protect from the UV RAYS.
910
-
-
... More
Exposing the corroded steel around its fulll circumference and cleaning the same to remove all loose scales and corrosion deposits by hard brush with emry paper or by any suitable mechanical means as directed bt engineer in charge. So as to get bright conditions and removing the corrosion deposits from pits and imperfections within its surface by compressed air and water at a high pressure and providing and applying one full coat of anti corrosive treatment of epoxy (Nitozinc primer/Zinc rich primer of FOSROC product) or any other equivalent approved compound over the cleaned and prepared surface as per manufactures specifications.
2
-
-
... More
Extra for providing and spraying bond coat 'Nito bond-SBR of FORSROC product for the entire surface to receive the coat prior to application of cement plaster.
2
-
-
... More
Providing and applying a bond coat of Nitobond -EP of FOSROC product to the exposed surfaces of all structural members as per the manufacturers specifications at all levels as directed by Engineer in charge.
2
-
-