Hyderabad Metropolitan Water Supply And Sewerage Board Tender
For getting the details of etenders, if you are looking for information about them from the cumbersome government websites but are tired of doing so, Bidassist comes up with a one stop solution. It collates every Eproc telangana tender on Bidassist. One can approach it for the bidding process, registration process, etc., are explained below.
Costs
EMD
Refer DocumentsDocument Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
346699Tender No
173/CGM (E)/O&MC-III /AME Works-D5/2022-23, Dt.21.07.2022. (4th Call)Tender Authority
Hyderabad Metropolitan Water Supply And Sewerage Board ViewPurchaser Address
-Website
http://https://www.hyderabadwater.gov.in/en/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
WATER SUPPLY;Earthwork excavation and depositing on the bank in all types of soils like black cotton soil, red earth, and ordinary gravel, hard gravelly soils, mixture of gravel, stoney earth and earth mixed with fair size boulders except rock requiring blasting with different lifts as per specifications and drawings and as directed by the departmental officers, including protecting the walls and other structures , existing water supply lines, sewers, power cables, telephone cables/ducts, storm water drains, traffic signals etc., wherever it is possible so as not to distrub the existing utility services etc., taking all precautionary measures in the restricted areas such as urban areas including diversion of the traffic,removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and including backfilling for pipeline trenches for laying Water supply/sewer lines including all incidental and operational charges etc., complete as directed by the HMWS&SB Engineers. (For Arresting water leakages , Rectification of pollution (Joint leakages), Clearing chowkages/blockages, rectification of No water supply and low water pressure complaints, Replacement of damaged pipes, Repair/replacement of sluice valves, Provision for dummy arrangements and Provision of scour valve arrangements on water supply lines for rectification of polluted water supply). etc., complete as directed by the departmental officers. (Pipe line trenches)
112.19
-
48882.93
WATER SUPPLY;Earthwork excavation and depositing on the bank in all types of soils like black cotton soil, red earth, and ordinary gravel, hard gravelly soils, mixture of gravel, stoney earth and earth mixed with fair size boulders except rock requiring blasting with different lifts as per specifications and drawings and as directed by the departmental officers, including protecting the walls and other structures , existing water supply lines, sewers, power cables, telephone cables/ducts, storm water drains, traffic signals etc., wherever it is possible so as not to distrub the existing utility services etc., taking all precautionary measures in the restricted areas such as urban areas including diversion of the traffic,removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and including backfilling for pipeline trenches for laying Water supply/sewer lines including all incidental and operational charges etc., complete as directed by the HMWS&SB Engineers. (For Arresting water leakages , Rectification of pollution (Joint leakages), Clearing chowkages/blockages, rectification of No water supply and low water pressure complaints, Replacement of damaged pipes, Repair/replacement of sluice valves, Provision for dummy arrangements and Provision of scour valve arrangements on water supply lines for rectification of polluted water supply). etc., complete as directed by the departmental officers. (Sewer manholes)
19.99
-
5670.03
WATER SUPPLY;Dewatering pipeline trenches duly bailing out water with engine driven pumps including hire charges fuel charges wages of driver and helper and all other incidental and operational charges including suction and delivery hoses lead of drain into natural drain etc. complete as directed by the departmental officer. (For Arresting water leakages on water supply lines (Joint leakages), Rectification of pollution on water supply lines, Clearing chowkages/blockages in water supply mains for rectification of No water supply and low water pressure complaints, Replacement of damaged of pipes, Repair/replacement of sluice valves, Provision of dummy arrangements on water supply lines and Provision of scour valve arrangements on water supply line for rectification of polluted water supply).
36
-
13637.52
WATER SUPPLY;Cutting of 100mm dia CI/DI Class pipes and specials with/without water in the main, including all incidental and operational charges etc., complete as directed by the H.M.W.S.&. S. Board Engineers. (For Arresting water leakages on water supply lines (Joint leakages), Rectification of pollution on water supply lines, Clearing chowkages/blockages in water supply mains for rectification of NO water supply and low water pressure complaints, Replacement of damaged of pipes, Repair/replacement of sluice valves, Provision of dummy arrangements on water supply lines and Provision of scour valve arrangements on water supply line for rectification of polluted water supply).
68
-
8697.2
WATER SUPPLY;Cutting of 150mm dia CI/DI Class pipes and specials with/without water in the main, including all incidental and operational charges etc., complete as directed by the H.M.W.S.&. S. Board Engineers. (For Arresting water leakages on water supply lines (Joint leakages), Rectification of pollution on water supply lines, Clearing chowkages/blockages in water supply mains for rectification of NO water supply and low water pressure complaints, Replacement of damaged of pipes, Repair/replacement of sluice valves, Provision of dummy arrangements on water supply lines and Provision of scour valve arrangements on water supply line for rectification of polluted water supply).
48
-
11510.4
WATER SUPPLY;Cutting of 200mm dia CI/DI Class pipes and specials with/without water in the main, including all incidental and operational charges etc., complete as directed by the H.M.W.S.&. S. Board Engineers. (For Arresting water leakages , Rectification of pollution (Joint leakages), Clearing chowkages/blockages, rectification of No water supply and low water pressure complaints, Replacement of damaged pipes, Repair/replacement of sluice valves, Provision for dummy arrangements and Provision of scour valve arrangements on water supply lines for rectification of polluted water supply). etc., complete as directed by the departmental officers.
23
-
7353.1
WATER SUPPLY;Cutting of 250mm dia CI/DI Class pipes and specials with/without water in the main, including all incidental and operational charges etc., complete as directed by the H.M.W.S.&. S. Board Engineers. (For Arresting water leakages , Rectification of pollution (Joint leakages), Clearing chowkages/blockages, rectification of No water supply and low water pressure complaints, Replacement of damaged pipes, Repair/replacement of sluice valves, Provision for dummy arrangements and Provision of scour valve arrangements on water supply lines for rectification of polluted water supply). etc., complete as directed by the departmental officers.
6
-
2397.6
WATER SUPPLY;Cutting of 300mm dia CI/DI Class pipes and specials with/without water in the main, including all incidental and operational charges etc., complete as directed by the H.M.W.S.&. S. Board Engineers. (For Arresting water leakages , Rectification of pollution (Joint leakages), Clearing chowkages/blockages, rectification of No water supply and low water pressure complaints, Replacement of damaged pipes, Repair/replacement of sluice valves, Provision for dummy arrangements and Provision of scour valve arrangements on water supply lines for rectification of polluted water supply). etc., complete as directed by the departmental officers.
6
-
2877.6
WATER SUPPLY;Jointing the 100mm dia CI/DI (K7) pipes and specials with S/S ends excluding cost of jointing materials such as lead or lead wool and hump yarn but including sundries such as cost of fuel for field test meting lead, filling with water with lead upto 500m and testing to required pressure including labour charges and all other operational & incidental charges etc., complete as directed by the H.M.W.S.&.S. Board Engineers (Reference to specification BIS No.3114/94/12288:1997). (For Arresting water leakages , Rectification of pollution (Joint leakages), Clearing chowkages/blockages, rectification of No water supply and low water pressure complaints, Replacement of damaged pipes, Repair/replacement of sluice valves, Provision for dummy arrangements and Provision of scour valve arrangements on water supply lines for rectification of polluted water supply). etc., complete as directed by the departmental officers.
68
-
17129.2
WATER SUPPLY;Jointing the 150mm dia CI/DI (K7) pipes and specials with S/S ends excluding cost of jointing materials such as lead or lead wool and hump yarn but including sundries such as cost of fuel for field test meting lead, filling with water with lead upto 500m and testing to required pressure including labour charges and all other operational & incidental charges etc., complete as directed by the H.M.W.S.&.S. Board Engineers (Reference to specification BIS No.3114/94/12288:1997). (For Arresting water leakages , Rectification of pollution (Joint leakages), Clearing chowkages/blockages, rectification of No water supply and low water pressure complaints, Replacement of damaged pipes, Repair/replacement of sluice valves, Provision for dummy arrangements and Provision of scour valve arrangements on water supply lines for rectification of polluted water supply). etc., complete as directed by the departmental officers.
48
-
15206.4
WATER SUPPLY;Jointing the 200mm dia CI/DI (K7) pipes and specials with S/S ends excluding cost of jointing materials such as lead or lead wool and hump yarn but including sundries such as cost of fuel for field test meting lead, filling with water with lead upto 500m and testing to required pressure including labour charges and all other operational & incidental charges etc., complete as directed by the H.M.W.S.&.S. Board Engineers (Reference to specification BIS No.3114/94/12288:1997) . (For Arresting water leakages , Rectification of pollution (Joint leakages), Clearing chowkages/blockages, rectification of No water supply and low water pressure complaints, Replacement of damaged pipes, Repair/replacement of sluice valves, Provision for dummy arrangements and Provision of scour valve arrangements on water supply lines for rectification of polluted water supply). etc., complete as directed by the departmental officers.
23
-
8098.3
WATER SUPPLY;Jointing the 250mm dia CI/DI (K7) pipes and specials with S/S ends excluding cost of jointing materials such as lead or lead wool and hump yarn but including sundries such as cost of fuel for field test meting lead, filling with water with lead upto 500m and testing to required pressure including labour charges and all other operational & incidental charges etc., complete as directed by the H.M.W.S.&.S. Board Engineers (Reference to specification BIS No.3114/94/12288:1997). (For Arresting water leakages , Rectification of pollution (Joint leakages), Clearing chowkages/blockages, rectification of No water supply and low water pressure complaints, Replacement of damaged pipes, Repair/replacement of sluice valves, Provision for dummy arrangements and Provision of scour valve arrangements on water supply lines for rectification of polluted water supply). etc., complete as directed by the departmental officers.
6
-
2383.2
WATER SUPPLY;Jointing the 300mm dia CI/DI (K7) pipes and specials with S/S ends excluding cost of jointing materials such as lead or lead wool and hump yarn but including sundries such as cost of fuel for field test meting lead, filling with water with lead upto 500m and testing to required pressure including labour charges and all other operational & incidental charges etc., complete as directed by the H.M.W.S.&.S. Board Engineers (Reference to specification BIS No.3114/94/12288:1997). (For Arresting water leakages , Rectification of pollution (Joint leakages), Clearing chowkages/blockages, rectification of No water supply and low water pressure complaints, Replacement of damaged pipes, Repair/replacement of sluice valves, Provision for dummy arrangements and Provision of scour valve arrangements on water supply lines for rectification of polluted water supply). etc., complete as directed by the departmental officers.
6
-
2716.8
WATER SUPPLY;Jointing the 100mm dia CI/DI (K7) pipes and fittings with flanged ends including cost of spun yarn and sundries such as cost of fuel for field test meting lead, filling with water with lead upto 500m and testing to required pressure including labour charges and all other operational & incidental charges etc., complete as directed by the H.M.W.S.&.S. Board Engineers (Reference to specification BIS No.3114/94/12288:1997). (For Arresting water leakages , Rectification of pollution (Joint leakages), Clearing chowkages/blockages, rectification of No water supply and low water pressure complaints, Replacement of damaged pipes, Repair/replacement of sluice valves, Provision for dummy arrangements and Provision of scour valve arrangements on water supply lines for rectification of polluted water supply). etc., complete as directed by the departmental officers.
16
-
4867.2
WATER SUPPLY;Jointing the 150mm dia CI/DI (K7) pipes and fittings with flanged ends including cost of spun yarn and sundries such as cost of fuel for field test meting lead, filling with water with lead upto 500m and testing to required pressure including labour charges and all other operational & incidental charges etc., complete as directed by the H.M.W.S.&.S. Board Engineers (Reference to specification BIS No.3114/94/12288:1997). (For Arresting water leakages , Rectification of pollution (Joint leakages), Clearing chowkages/blockages, rectification of No water supply and low water pressure complaints, Replacement of damaged pipes, Repair/replacement of sluice valves, Provision for dummy arrangements and Provision of scour valve arrangements on water supply lines for rectification of polluted water supply). etc., complete as directed by the departmental officers.
8
-
3614.4
WATER SUPPLY;Jointing the 200mm dia CI/DI (K7) pipes and fittings with flanged ends including cost of spun yarn and sundries such as cost of fuel for field test meting lead, filling with water with lead upto 500m and testing to required pressure including labour charges and all other operational & incidental charges etc., complete as directed by the H.M.W.S.&.S. Board Engineers (Reference to specification BIS No.3114/94/12288:1997). (For Arresting water leakages , Rectification of pollution (Joint leakages), Clearing chowkages/blockages, rectification of No water supply and low water pressure complaints, Replacement of damaged pipes, Repair/replacement of sluice valves, Provision for dummy arrangements and Provision of scour valve arrangements on water supply lines for rectification of polluted water supply). etc., complete as directed by the departmental officers.
12
-
5966.4
WATER SUPPLY;Jointing the 250mm dia CI/DI (K7) pipes and fittings with flanged ends including cost of spun yarn and sundries such as cost of fuel for field test meting lead, filling with water with lead upto 500m and testing to required pressure including labour charges and all other operational & incidental charges etc., complete as directed by the H.M.W.S.&.S. Board Engineers (Reference to specification BIS No.3114/94/12288:1997). (For Arresting water leakages , Rectification of pollution (Joint leakages), Clearing chowkages/blockages, rectification of No water supply and low water pressure complaints, Replacement of damaged pipes, Repair/replacement of sluice valves, Provision for dummy arrangements and Provision of scour valve arrangements on water supply lines for rectification of polluted water supply). etc., complete as directed by the departmental officers.
6
-
4098
WATER SUPPLY;Jointing the 300mm dia CI/DI (K7) pipes and fittings with flanged ends including cost of spun yarn and sundries such as cost of fuel for field test meting lead, filling with water with lead upto 500m and testing to required pressure including labour charges and all other operational & incidental charges etc., complete as directed by the H.M.W.S.&.S. Board Engineers (Reference to specification BIS No.3114/94/12288:1997). (For Arresting water leakages , Rectification of pollution (Joint leakages), Clearing chowkages/blockages, rectification of No water supply and low water pressure complaints, Replacement of damaged pipes, Repair/replacement of sluice valves, Provision for dummy arrangements and Provision of scour valve arrangements on water supply lines for rectification of polluted water supply). etc., complete as directed by the departmental officers.
4
-
2926.8
WATER SUPPLY;Supply delivery and filling of quarry dust (20% Rubbish 80% HBG Stone 6mm) where ever required as directed by departmental officers including cost and conveyance stacking leveling watering tampering rolling all leads lobour charges and other incidental and operational charghes etc. complete as directed by the HMWS&SB Engineers. (For Arresting water leakages , Rectification of pollution (Joint leakages), Clearing chowkages/blockages, rectification of No water supply and low water pressure complaints, Replacement of damaged pipes, Repair/replacement of sluice valves, Provision for dummy arrangements and Provision of scour valve arrangements on water supply lines for rectification of polluted water supply). etc., complete as directed by the departmental officers.
20.01
-
11889.94
WATER SUPPLY;Plain Cement Concrete M10 with 6mm to 20 mm guage hard granite machine crushed metal including cost and conveyance of all meterial to site, machine mixing of concrete, lifts, leads, form work laying in position, vibrating, compacting, curing, all labour charges, tools and plants and all other incidental and operational charges etc. complete as directed by departmental officers as directed by the H.M.W.S.&,S. Board Engineers . (For Arresting water leakages , Rectification of pollution (Joint leakages), Clearing chowkages/blockages, rectification of No water supply and low water pressure complaints, Replacement of damaged pipes, Repair/replacement of sluice valves, Provision for dummy arrangements and Provision of scour valve arrangements on water supply lines for rectification of polluted water supply). etc., complete as directed by the departmental officers.
5.62
-
33270.68
WATER SUPPLY;Plain Cement Concrete M20 with 6mm to 20 mm guage hard granite machine crushed metal including cost and conveyance of all meterial to site, machine mixing of concrete, lifts, leads, form work laying in position, vibrating, compacting, curing, all labour charges, tools and plants and all other incidental and operational charges etc. complete as directed by departmental officers as directed by the H.M.W.S.&,S. Board Engineers. (For Arresting water leakages , Rectification of pollution (Joint leakages), Clearing chowkages/blockages, rectification of No water supply and low water pressure complaints, Replacement of damaged pipes, Repair/replacement of sluice valves, Provision for dummy arrangements and Provision of scour valve arrangements on water supply lines for rectification of polluted water supply). etc., complete as directed by the departmental officers.
22.98
-
140118.02
WATER SUPPLY;Carting away the surplus excavated materials such as rock / earth from the site to a suitable distance of about 8 Kms including loading, unloading, conveyance charges and dumping the carted material at the contractors cost labour charges, all leads and lifts, all other incidential and operational charges etc., complete. as directed by the H.M.W.S.&. S. Board Engineers.
74.07
-
11584.55
WATER SUPPLY;Making dummy arrangements to existing 100mm dia WS main at tail end point with socket tail piece and MS dummy plate, lead joints including including cost and conveyance of all materials including all other incidental and operation charges etc., complete as directed by the HMWS&SB Engineer.
8
-
40256
WATER SUPPLY;Making dummy arrangements to existing 150mm dia WS main at tail end point with socket tail piece and MS dummy plate, lead joints including including cost and conveyance of all materials including all other incidental and operation charges etc., complete as directed by the HMWS&SB Engineer.
4
-
34364.88
WATER SUPPLY;Removing and raising of RCC precast manhole chambers water supply manholes with laying of CC Prop. 1:4:8 and 1:2:4 for benching including cost of materials, labour charges but excluding cost of RCC precast manhole etc., complete as directed by the HMWS&SB Engineer.
18
-
102924
WATER SUPPLY;Redoing of PPC connection for domestic water supply connection incluidng earth work excavation cost of pipe refilling etc., complete as directed by the HMWS&SB Engineers. (for 15mm dia & 20mm dia)
45
-
10534.5
WATER SUPPLY;Supply and delivery of Cement including cost and conveyance etc. complete as directed by the H.M.W.S.&,S. Board Engineers. (For Arresting water leakages , Rectification of pollution (Joint leakages), Clearing chowkages/blockages, rectification of No water supply and low water pressure complaints, Replacement of damaged pipes, Repair/replacement of sluice valves, Provision for dummy arrangements and Provision of scour valve arrangements on water supply lines for rectification of polluted water supply). etc., complete as directed by the departmental officers.
923.36
-
5263.15
WATER SUPPLY;Supply and delivery of Spun Yarn including cost and conveyance etc. complete as directed by the H.M.W.S.&,S. Board Engineers. (For Arresting water leakages , Rectification of pollution (Joint leakages), Clearing chowkages/blockages, rectification of No water supply and low water pressure complaints, Replacement of damaged pipes, Repair/replacement of sluice valves, Provision for dummy arrangements and Provision of scour valve arrangements on water supply lines for rectification of polluted water supply). etc., complete as directed by the departmental officers.
61.68
-
8018.4
WATER SUPPLY;Replacement of 100mm dia MS Pipe in place of damaged CI/DI pipes including cost and conveyance etc. complete as directed by the H.M.W.S.&,S. Board Engineers. (For Arresting water leakages , Rectification of pollution (Joint leakages), Clearing chowkages/blockages, rectification of No water supply and low water pressure complaints, Replacement of damaged pipes, Repair/replacement of sluice valves, Provision for dummy arrangements and Provision of scour valve arrangements on water supply lines for rectification of polluted water supply). etc., complete as directed by the departmental officers.
6
-
11973.6
WATER SUPPLY;Replacement of 150mm dia MS Pipe in place of damaged CI/DI pipes including cost and conveyance etc. complete as directed by the H.M.W.S.&,S. Board Engineers. (For Arresting water leakages , Rectification of pollution (Joint leakages), Clearing chowkages/blockages, rectification of No water supply and low water pressure complaints, Replacement of damaged pipes, Repair/replacement of sluice valves, Provision for dummy arrangements and Provision of scour valve arrangements on water supply lines for rectification of polluted water supply). etc., complete as directed by the departmental officers.
3
-
8754.51
WATER SUPPLY;Replacement of 200mm dia MS Pipe in place of damaged CI/DI pipes including cost and conveyance etc. complete as directed by the H.M.W.S.&,S. Board Engineers. (For Arresting water leakages , Rectification of pollution (Joint leakages), Clearing chowkages/blockages, rectification of No water supply and low water pressure complaints, Replacement of damaged pipes, Repair/replacement of sluice valves, Provision for dummy arrangements and Provision of scour valve arrangements on water supply lines for rectification of polluted water supply). etc., complete as directed by the departmental officers.
6
-
23020.5
WATER SUPPLY;Manufacturing, supply & delivery of SS spindle rod with chuck nut including cost and conveyance etc. complete as directed by the H.M.W.S.&,S. Board Engineers.
242.4
-
88476
WATER SUPPLY;Manufacturing, supply & delivery of SS spindle rod with chuck nut including cost and conveyance etc. complete as directed by the H.M.W.S.&,S. Board Engineers Duduct old rod @ 80% i.e., 193.92 X Rs:30.00/kg = 5817.60.
-193.92
-
-5817.6
WATER SUPPLY;Supply and delivery fixing of RCC Precast manhole chambers having the size of 36"x21" dia at top fixing in CC 1:4:8 Prop:along with FRC Cover and frame laying CC 1:2:4 prop: including cost of materials labour charges earth work curing conveyance etc., complete as directed by the by the H.M.W.S.&,S. Board Engineers
13
-
85410
WATER SUPPLY;Engaging labour of cleaning light jungle and bushes grown in the premises of reservoir whenever and wherever required duly cutting and stacking with an initial lead and lift and disposal duly burning including the labour charges and the tools and tackles along with all other incidental and operational charges etc., complete as directed by the by the H.M.W.S.&,S. Board Engineers .(Per year 5 time x 10 Persons) for 2 years
20
-
13720
WATER SUPPLY;Repair of sluice valves 500/600mm sluice valve operating system gear box spare parts and over hauling including the labour charges and tools and tackles along with all other incidental and operational charges etc., complete as directed by the by the H.M.W.S.&,S. Board Engineers.
2
-
200000
WATER SUPPLY;Supply, delivery and fixing of level gauge including labour charges along with all other incidental and operational charges etc., complete as directed by the by the H.M.W.S.&,S. Board Engineers.
2
-
20000
WATER SUPPLY;Supply, delivery and fixing of sign boards including labour charges along with all other incidental and operational charges etc., complete as directed by the by the H.M.W.S.&,S. Board Engineers.
1
-
10000
WATER SUPPLY;Supply, delivery of 100mm dia Sluice Valve Key Rods including labour charges along with all other incidental and operational charges etc., complete as directed by the by the H.M.W.S.&,S. Board Engineers.
5
-
17500
WATER SUPPLY;Supply, delivery of 150mm dia Sluice Valve Key Rods including labour charges along with all other incidental and operational charges etc., complete as directed by the by the H.M.W.S.&,S. Board Engineers.
3
-
13500
WATER SUPPLY;Supply, delivery of 200mm dia Sluice Valve Key Rods including labour charges along with all other incidental and operational charges etc., complete as directed by the by the H.M.W.S.&,S. Board Engineers.
1
-
5500
WATER SUPPLY;Supply, delivery of 250mm dia Sluice Valve Key Rods including labour charges along with all other incidental and operational charges etc., complete as directed by the by the H.M.W.S.&,S. Board Engineers.
1
-
6500
WATER SUPPLY;Supply, delivery of 300mm dia Sluice Valve Key Rods including labour charges along with all other incidental and operational charges etc., complete as directed by the by the H.M.W.S.&,S. Board Engineers.
1
-
7500