Hyderabad Metropolitan Water Supply And Sewerage Board Tender
For getting the details of etenders, if you are looking for information about them from the cumbersome government websites but are tired of doing so, Bidassist comes up with a one stop solution. It collates every Eproc telangana tender on Bidassist. One can approach it for the bidding process, registration process, etc., are explained below.
Costs
EMD
Refer DocumentsDocument Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
525458Bid Award Id
ViewTender No
e-Tender Notification No.EP-33/CGM(E)/TC/T1/Silce-I/Div-VIII/2024-25, Date: 05-07-2024Tender Authority
Hyderabad Metropolitan Water Supply And Sewerage Board ViewPurchaser Address
-Website
http://https://www.hyderabadwater.gov.in/en/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Replacement of 1000 mm dia PhI PSC of MWSS Pumping main from Kasi Vishwesharaya temple Kaman Kalab;Prepartionary works for taking shut down like operating the scour valves for dewatering before starting the shut down and closing the same after completion of the work and checking of Air valves during commissioning of line etc including hire charges for vehicle for transportation of men and materials including all incidental and operational charges etc., complete as directed by dept officers.
1
29700
29700
... More
Replacement of 1000 mm dia PhI PSC of MWSS Pumping main from Kasi Vishwesharaya temple Kaman Kalab;De watering of water from pipe line trenches using 10 HP diesel driven pump sets including all necessary men and machinery etc. complete as directed by the departmental officers. Junction & Laying period complete as directed by the DEPT Officers,
960
443
426144
... More
Replacement of 1000 mm dia PhI PSC of MWSS Pumping main from Kasi Vishwesharaya temple Kaman Kalab;De watering of water from pipe line trenches using 5 HP diesel driven pump sets including all necessary men and machinery etc. complete as directed by the departmental officers. Junction & Laying period complete as directed by the DEPT Officers,
960
302
290496
... More
Replacement of 1000 mm dia PhI PSC of MWSS Pumping main from Kasi Vishwesharaya temple Kaman Kalab;Cutting open and removing of 1000 mm dia PSC pipes for length of 1 pipe each from its joints carefully by field gas cutting of the HT wires, hire charges of gas cutting equipment and all consumables and shifting the old pipe to suitable place etc with all other Incidental and operational charges ete complete as directed by the dept Officers.
2
31499
62998
... More
Replacement of 1000 mm dia PhI PSC of MWSS Pumping main from Kasi Vishwesharaya temple Kaman Kalab;Carting surplus excavated earth and rock from the site to a suitable distance including loading, unloading conveyance and dumping labor charges, all leads and lifts all other incidental and operational charges etc. complete as directed by the departmental officers.
3914.44
181
708905.08
... More
Replacement of 1000 mm dia PhI PSC of MWSS Pumping main from Kasi Vishwesharaya temple Kaman Kalab;Refilling with usefull available excavated earth/soils in trenches sides of foundations & basement and the pipeline trenches after laid, jointed, executed, tested with initial lead in layers not exceeding 15 cm thick, consolidating each deposited layer by watering consolidting each layer by watering and ramming including cost and conveyonce of water to work site and all operational Incidental, labour charges, hire charges of T&P complete for finished item of work complete as directed by the departmental officers.
1431.56
38
54971.9
... More
Replacement of 1000 mm dia PhI PSC of MWSS Pumping main from Kasi Vishwesharaya temple Kaman Kalab;Supply and delivery of HYSD bars of FE 415 grade of various diameters including cost and conveyance to site, labour charges for straightening, cutting, bending and fabrication of reinforcement, Including placing in position, binding and all labour charges and cost binding wire for tying the rods, all lead lifts tools and plants all incidental and operational charges etc complete for RCC chamber pedestals and thrust blocks etc. complete as directed by the departmental officers.
9.09
68071
618765.39
... More
Replacement of 1000 mm dia PhI PSC of MWSS Pumping main from Kasi Vishwesharaya temple Kaman Kalab;Plain Cement Concrete PCC M 20 Nominal Mix; using 20 mm guage hard granite machine crushed metal including cost and conveyance of all materials to site, centering, machine mixing, lifts and delifts, leads, laying in position, compacting, curing, all labour charges, etc., complete as directed by the departmental officers.
371.71
6841
2542868.11
... More
Replacement of 1000 mm dia PhI PSC of MWSS Pumping main from Kasi Vishwesharaya temple Kaman Kalab;Barricading, hoarding, lighting and watching etc., for water supply and sewerage works for trenches of depths upto 6-0" (2 Meter) below G.L as per with Bamboo ete, complete as directed by the departmental officers.
1620
216
349920
... More
Replacement of 1000 mm dia PhI PSC of MWSS Pumping main from Kasi Vishwesharaya temple Kaman Kalab;Manufacture of MS Squirrel cage of size 2.0 X 1.50 X 2.00m made up of ISA 50 X 50 X 6mm angular and MS Chequered Plate with 10mm Square rods including cost of materials, Fabrication charges, transportation charges etc complete as directed by the Departmental Officers.
2
31775
63550
... More
Replacement of 1000 mm dia PhI PSC of MWSS Pumping main from Kasi Vishwesharaya temple Kaman Kalab;Manufacture supply and delivery of 150mm dia MS pipe fabricated with 10mm thick MS plate for including cost of plate, fabrication, matching and turning charges complete as directed by the departmental officers.
20
4155
83100
... More
Replacement of 1000 mm dia PhI PSC of MWSS Pumping main from Kasi Vishwesharaya temple Kaman Kalab;Junction work for connecting new 150mm dia MS pipe and MS specials to the 1000 mm dia MS pipe true to alignment and gradient and making 3lines are welding fixing of sluice valve & Air valve with new rubber packing, tightening with nuts and bolts laying and jointing of 150mm dia MS pipe including cost of labour charges cost and conveyance of all incidental and operational charges etc., complete as directed by the departmental officers.
2
39076
78152
... More
Replacement of 1000 mm dia PhI PSC of MWSS Pumping main from Kasi Vishwesharaya temple Kaman Kalab;RCC M-20 Nominal mix (Cement:fine aggregate: course aggregate) corresponding to Table 9 of IS 456 using 20mm size graded machine crushed hard granite metal (coarse aggregate) from approved quarry Including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc.. to site including all operational, incidental and labour charges such as machine mixing, laying concrete, curing etc.,complete but excluding cost of steel and its fabrication charges for finished item of work, including centering, shuttering. For Butterfly valve chambers & 300 mm dia scour chambers.
15.15
14506
219765.9
... More
Replacement of 1000 mm dia PhI PSC of MWSS Pumping main from Kasi Vishwesharaya temple Kaman Kalab;Hoisting, keeping, laying, fixing and Jointing of 1000mm dia Butterfly Valve by connecting to the new MS pipe 1000 mm dia true alingiment and gradient and ines are welding with required materials then after fixing of butterfly valve with new rubber packing and other materials and tightening with nuts and bolts including cost of labour charges, Hydraulic crane, Generator, Truck, cost and conveyance of all incidential and operational charges etc., complete as directed by the departmental officers.
1
185640
185640
... More
Replacement of 1000 mm dia PhI PSC of MWSS Pumping main from Kasi Vishwesharaya temple Kaman Kalab;Cost of M.S Flanges including cost of bolts, nuts, rubber packing etc., complete and flange thickness conforming to IS:7322-1985 and flange dimensions conforming to IS:1538-1993 excluding cost of MS specials including cost and conveyance to site etc., complete as directed by the departmental officers.(For 150 mm dia x 15mm thick).
2
1954
3908
... More
Replacement of 1000 mm dia PhI PSC of MWSS Pumping main from Kasi Vishwesharaya temple Kaman Kalab;Cost of M.S Flanges including cost of bolts, nuts, rubber packing etc., complete and flange thickness conforming to IS:7322-1985 and flange dimensions conforming to IS:1538-1993 excluding cost of MS specials including cost and conveyance to site etc., complete as directed by the departmental officers.(For 1000 mm dia x 25mm thick).
2
26828
53656
... More
Replacement of 1000 mm dia PhI PSC of MWSS Pumping main from Kasi Vishwesharaya temple Kaman Kalab;Manufacture, Supply and delivery of DI D/F Butterfly Valves with GGG-40/SG-400/15 or GGG- 50/SG-500/7 or equivalent grade as per I.S.3896-part 2-1985 and subsequent revisions, Double eccentrically Disc., with renewable soft seal on the dise and Body seat face of stainless steel / nickel weld overlay, with powder or liquid Epoxy coating with minimum thickness of 250 microns applied on both body and disc inside and outside. Face to face dimensions as per AWWA C 504 or BS 5155 or IS:13095. Drilled as per requirement of dept.
1
916193
916193.25
... More
Replacement of 1000 mm dia PhI PSC of MWSS Pumping main from Kasi Vishwesharaya temple Kaman Kalab;Manufacture, Supply and Delivery of DI D/F Gate Valves (Soft Seated) Resilient seated soft sealing gate valves (Sluice valves) with body bonnet of ductile cast iron of grade GGG-40/ SG- 400/15 or GGG-50/SG-500/7 or equivalent grade as per I.S.3896- part2-1985 and subsequent revisions, wedge fully rubber lined with EPDM food grade quality and seals of NBR and the valves should be of vacuum tight and 100% leak proof with face to face dimensions as per BS5163-IS14846-2000/DIN 3202 F 4. All the valves should be with Electrostatic powder coating both inside and outside pocket less body passage. Drilled as per requirement of the dept officers (PN-16).
2
20555
41111.7
... More
Replacement of 1000 mm dia PhI PSC of MWSS Pumping main from Kasi Vishwesharaya temple Kaman Kalab;Manufacture, Supply and deivery of single chamber DI Air Valve with Body and cover in Ductile Iron of grade GGG-40/SG-400/15 GGG-50/SG-500/7 or equivalent grade as per I.S.3896-part2- 1985 and subsequent revisions. All internal parts such as float, shell etc., all cover bolts, of stainless steel, and Gaskets and seals of EPDM food grade quality Epoxy powder coating (EP-P) inside and outside colour blue. Drilled as per requirement of the dept officer. (150mm dia (PN-16))
2
61212
122425.8
... More
Replacement of 1000 mm dia PhI PSC of MWSS Pumping main from Kasi Vishwesharaya temple Kaman Kalab;1000mm dia Bends (31-45)
6
95974
575846.22
... More
Replacement of 1000 mm dia PhI PSC of MWSS Pumping main from Kasi Vishwesharaya temple Kaman Kalab;1000mm dia Bends (0-30)
10
68327
683271.8
... More
Replacement of 1000 mm dia PhI PSC of MWSS Pumping main from Kasi Vishwesharaya temple Kaman Kalab;Manufacture as per BIS:12820/2004 with S.B.R. Quality of 1000 mm dia Rubber rings confirming to BIS: 5382/85, supply and delivery of Rubber Gaskets suitable for C.I/D.I S/S pipes anywhere in T.G. F.O.R. Destination departmental stores including cost of material, loading, incidental handling with companies standard packing, transportation, etc complete as directed by the departinental officers.
2
1911
3822
... More
Replacement of 1000 mm dia PhI PSC of MWSS Pumping main from Kasi Vishwesharaya temple Kaman Kalab;Cost of Machine End pair (Socket +Spigot) with 100mm length MS Barrel on each side of Socket and Spigot for providing M.S Specials on PSC pipelines excluding cost of M.S Specials & Taxes but including cost of conveyance to site etc., complete as directed by the departmental officers. For 1000 mm dia
1
34977
34977
... More
Replacement of 1000 mm dia PhI PSC of MWSS Pumping main from Kasi Vishwesharaya temple Kaman Kalab;Manufacturing and supply of MS pipes using 10mm thick MS plate Manufactured with electric resistance welding (ERW) or submerged arc welding (SAW) process longitudinally or spirally welded from MS plates confirming to IS:2062, Grade- A 'B' in suitable lengths to suit the site conditions as directed by the departmental officers, including Hydraulic testing at 24 Kg/Sq cm pressure at factory including inlining with cement mortar (1:2) 15mm thick using 6 Nos of 6mm dia MS rings at each end of the pipe and outcoating with cement mortar (1:3) prop. 30mm. thick by shotcreting or guniting duly providing wire mesh of size 50x50x3mm including cost of MS Plates welding rods, cement, sand, reinforcement, wire mesh and all other required materials, and excluding of all taxes and duties and delivery of fabricated Inlined and outcoated pipes to site and hoisting and carefully lowering the pipes into ready made trenches or keeping in position on ready built pedestals or supports and laying them true to alignment and gradient and perfect lining by jacking and joinitng with three run arc welding and inlining and outcoating of field welded joints with wire mesh and cement mortar as per the above specification inclusive of cost of all jointing materials, labour charges and other incidental and operational charges etc., complete as directed by departmental officers.
810
32569
26381691.9
... More
Replacement of 1000 mm dia PhI PSC of MWSS Pumping main from Kasi Vishwesharaya temple Kaman Kalab;Providing, Laying, Spreading and compacting graded HBG crushed stone aggregate to Wet Mix Macadem specification including cost of all materials and including premixing the material with water at OMC in Mechanical mix plant carriage of mixed material by tipper to site, laying in uniform layers with paver in base courses on well prepared surface and compacting with Vibratory roller to acheive the desired density etc., as directed by the Engineer-in-Charge and as per MoRT&H specification 406 (5th revision) for finished item of work.
534.6
2732
1460527.2
... More
Replacement of 1000 mm dia PhI PSC of MWSS Pumping main from Kasi Vishwesharaya temple Kaman Kalab;Collection supply and filling with HBG Stone chips 2.36mm and below in trenches of foundations & basement and the pipeline trenches with initial lead in layers not exceeding 15 cm thick, consolidating each deposited layer by watering consolidting each layer by watering and ramming including cost of collection of sand and otehr required materials conveyonce of water to work site and all operational, incidental, labour charges, hire charges of T&P., complete for finished item of work, excluding GST.
264
1060
279840
... More
Replacement of 1000 mm dia PhI PSC of MWSS Pumping main from Kasi Vishwesharaya temple Kaman Kalab;Collection supply and filling with Gravel in trenches sides of foundations & basement wherever necessary and the pipeline trenches after laid, jointed, executed, tested with intial lead in layers not exceeding 15 cm thick, consolidating each deposited layer by watering consolidting each layer by watering and ramming including cost and conveyonce of gravel water to work site and all operational incidental, labour charges, hire charges of T&P complete for finished item of work.
1692.9
539
912473.1
... More
Replacement of 1000 mm dia PhI PSC of MWSS Pumping main from Kasi Vishwesharaya temple Kaman Kalab;Cutting open CC road surface, including labour charges and all other incidental and operational charges tools and plants etc complete as directed by the departmental officers for pipeline trenches.
26.4
2842
75028.8
... More
Replacement of 1000 mm dia PhI PSC of MWSS Pumping main from Kasi Vishwesharaya temple Kaman Kalab;Cutting open BT road surface(as well as asphalt concrete upto 75mm thick) including water bound macadam including labour charges all leads, lifts and conveyance of all material etc complete as directed by the departmental officers for pipeline trenches.
88
154
13552
... More
Replacement of 1000 mm dia PhI PSC of MWSS Pumping main from Kasi Vishwesharaya temple Kaman Kalab;Excavation in Hard rock (blasting prohibited) with benching, chiselling and wedging such as hard rock, sheet rock and boulders in habitant areas where controlled blasting can not be done with different lifts as per specifications and drawings and as directed by the departmental officers, including protecting walls and other structures, existing water supply lines, sewers, power cables, telephone cables/ducts, storm water drains, traffic signals etc.. wherever it is possible so as not to distrub the existing utility services etc., taking all precautionary measures in the restricted areas such as urban areas diversion of the traffic, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and excluding backfilling for pipeline trenches for laying sewer/ Water supply lines/ Foundations including all incidental and operational charges etc., complete as directed by the departmental officers.
267.3
3827
1022957.1
... More
Replacement of 1000 mm dia PhI PSC of MWSS Pumping main from Kasi Vishwesharaya temple Kaman Kalab;Earthwork excavation and depositing on the bank in all types of soils like black cotton soil, red earth, and ordinary gravel, hard gravelly soils, mixture of gravel, soft disintegrated rock,hard disintegrated rock, Conglomerated rock, stoney earth and earth mixed with fair size boulders except rock requiring blasting with different lifts as per specifications and drawings and as directed by the departmental officers, including protecting the walls and other structures, existing water supply lines, sewers, power cables, telephone cables/ ducts, storm water drains, traffic signals etc., wherever it is possible so as not to distrub the existing utility services etc., taking all precautionary measures in the restricted areas such as urban areas including diversion of the traffic, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and excluding backfilling for pipeline trenches for laying sewer/ Water supply lines including all incidental and operational charges and perfect lining by jacking and joinitng with three run are welding and inlining and outcoating of field welder complete as directed by dept officers.
5078.7
176
896390.55