Hyderabad Metropolitan Water Supply And Sewerage Board Tender
For getting the details of etenders, if you are looking for information about them from the cumbersome government websites but are tired of doing so, Bidassist comes up with a one stop solution. It collates every Eproc telangana tender on Bidassist. One can approach it for the bidding process, registration process, etc., are explained below.
Hyderabad Metropolitan Water Supply And Sewerage Board - HMWSSB Tender
Electrical and Electronics
Electrical Works
Opening Date30 Dec 2024
Closing Date2 Jan 2025
Tender Amount₹ 52,29,110
Costs
EMD
₹ 52,291Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
565098Tender No
EP-168(3rd Call)/CGM(E)/RC/2024-25, Dt:30.12.2024Tender Authority
Hyderabad Metropolitan Water Supply And Sewerage Board ViewPurchaser Address
-Website
http://https://www.hyderabadwater.gov.in/en/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Providing annual maintenance services;Providing annual maintenance to (9)Nos block type Blue Star Make cassette type ODU BVRF 21 TCE BVRF/IVRF systems for breakdown calls servicing the machine for the entire outdoor and indoor units in regular intervals. The above work includes day to day inspection, regular maintenance such as Indoor, outdoor coil cleaning, filter cleaning, replacement of differnt type of Indoor, outdoor sensors,filters, coils materials like Indoor, outdoor fan motors, refrigerant gases ,electronic parts such as power contractors, outdoor MCB's and service consumables and regular servicing of equipments etc. complete as directed by the HMWS&SB Engineers for the period of 12 months excluding condensers and Evaporator Coils, replacement of units, copper piping,electrical cabling, Major electronice parts such as Compressors, 3B controllers & outdoor main PCB. The different types of HVAC systems annual maintenance and servicing including technicain, labour charges, transportation, loading & unloading charges at front administrative building block etc,complete as directed by the departmental officers. (Rate as per Lowest quotation/Sanctioned Estimate) Located at 6th floor. For ground floor Located at 6th floor. For 1st floor Located at 6th floor. For 4th floor Located at 6th floor. For 5th floor
108
12120
1308960
... More
Providing annual maintenance services;Providing annual maintenance to (1)No block type Blue Star Make cassette type ODU IVRF 12 TCE BVRF/IVRF systems for breakdown calls servicing the machine for the entire outdoor and indoor units in regular intervals. The above work includes day to day inspection, regular maintenance such as Indoor, outdoor coil cleaning, filter cleaning, replacement of differnt type of Indoor, outdoor sensors,filters, coils materials like Indoor, outdoor fan motors, refrigerant gases ,electronic parts such as power contractors, outdoor MCB's and service consumables and regular servicing of equipments etc. complete as directed by the HMWS&SB Engineers for the period of 12 months excluding condensers and Evaporator Coils, replacement of units, copper piping,electrical cabling, Major electronice parts such as Compressors, 3B controllers & outdoor main PCB. The different types of HVAC systems annual maintenance and servicing including technicain, labour charges, transportation, loading & unloading charges at front administrative building block etc,complete as directed by the departmental officers. (Rate as per Lowest quotation/Sanctioned Estimate) Located at 6th floor. For 1st floor
12
7190
86280
... More
Providing annual maintenance services;Providing annual maintenance to (1)No block type Blue Star Make cassette type ODU IVRF 16 TCE BVRF/IVRF systems for breakdown calls servicing the machine for the entire outdoor and indoor units in regular intervals. The above work includes day to day inspection, regular maintenance such as Indoor, outdoor coil cleaning, filter cleaning, replacement of differnt type of Indoor, outdoor sensors,filters, coils materials like Indoor, outdoor fan motors, refrigerant gases ,electronic parts such as power contractors, outdoor MCB's and service consumables and regular servicing of equipments etc. complete as directed by the HMWS&SB Engineers for the period of 12 months excluding condensers and Evaporator Coils, replacement of units, copper piping,electrical cabling, Major electronice parts such as Compressors, 3B controllers & outdoor main PCB. The different types of HVAC systems annual maintenance and servicing including technicain, labour charges, transportation, loading & unloading charges at front administrative building block etc,complete as directed by the departmental officers. (Rate as per Lowest quotation/Sanctioned Estimate) Located at 1st floor - 1 No.
12
9580
114960
... More
Providing annual maintenance services;Providing annual maintenance to (24)Nos Blue Star/ VOLTAS/ DAIKIN/ CARRIER/MITHIBUSHI/O General Make Non VRF Cassette AC 3.3/3.8/4.0 Ton individual indoor and outdoor units for breakdown calls servicing the machine for the entire outdoor and indoor units in regular intervals. The above work includes day to day inspection, regular maintenance such as Indoor, outdoor coil cleaning, filter cleaning, replacement of differnt type of Indoor sensors,filters, IDU/ODU coils materials like Indoor, outdoor fan motors, refrigerant gases ,electronic parts such as power contractors, outdoor MCB's and service consumables and regular servicing of equipments etc. complete as directed by the HMWS&SB Engineers for the period of 12 months excluding condensers and Evaporator Coils, replacement of units, copper piping, electrical cabling, Major electronice parts such as Compressors, IDU main PCB. The different types of AC systems annual maintenance and servicing including technicain, labour charges, transportation, loading & unloading charges at Front & Rear administrative building blocks etc,complete as directed by the departmental officers. (Rate as per Lowest quotation/Sanctioned Estimate) Front building located at 1st floor Front building located at 2nd floor Front building located at 4th floor Front building located at 5th floor Rear building located at ground floor
288
1620
466560
... More
Providing annual maintenance services;Providing annual maintenance to (16)Nos Blue Star / VOLTAS/ DAIKIN/ CARRIER/MITHIBUSHI/O General Make Tower AC 3.3/3.8/4.0 Ton individual indoor and outdoor units for breakdown calls servicing the machine for the entire outdoor and indoor units in regular intervals. The above work includes day to day inspection, regular maintenance such as Indoor, outdoor coil cleaning, filter cleaning, replacement of differnt type of Indoor sensors,filters, IDU/ODU coils materials like Indoor, outdoor fan motors, refrigerant gases ,electronic parts such as power contractors, outdoor MCB's and service consumables and regular servicing of equipments etc. complete as directed by the HMWS&SB Engineers for the period of 12 months excluding condensers and Evaporator Coils, replacement of units, copper piping, electrical cabling, Major electronice parts such as Compressors, IDU main PCB. The different types of AC systems annual maintenance and servicing including technicain, labour charges, transportation, loading & unloading charges at Front & Rear administrative building blocks etc., complete as directed by the departmental officers. (Rate as per Lowest quotation/Sanctioned Estimate) Front building located at ground floor Front building located at 1st floor Front building located at 2nd floor Front building located at 5th floor Rear building located at ground floor Theme Park located at 51, Jubilee Hills
192
1410
270720
... More
Providing annual maintenance services;Providing annual maintenance to (9)Nos Blue Star/ VOLTAS/DAIKIN/ CARRIER/MITHIBUSHI/O General Make Spilt AC 2.20 Ton individual indoor and outdoor units for breakdown calls servicing the machine for the entire outdoor and indoor units in regular intervals. The above work includes day to day inspection, regular maintenance such as Indoor, outdoor coil cleaning, filter cleaning, replacement of differnt type of Indoor sensors,filters, IDU/ODU coils materials like Indoor, outdoor fan motors, refrigerant gases ,electronic parts such as power contractors, outdoor MCB's and service consumables and regular servicing of equipments etc. complete as directed by the HMWS&SB Engineers for the period of 12 months excluding condensers and Evaporator Coils, replacement of units, copper piping, electrical cabling, Major electronice parts such as Compressors, IDU main PCB. The different types of AC systems annual maintenance and servicing including technicain, labour charges, transportation, loading & unloading charges at Front & Rear administrative building blocks etc., complete as directed by the departmental officers. (Rate as per Lowest quotation/Sanctioned Estimate) Front building located at ground floor Front building located at 1st floor Front building located at 2nd floor Front building located at 3rd floor Front building located at 4th floor Front building located at 6th floor
108
1130
122040
... More
Providing annual maintenance services;Providing annual maintenance to (22)Nos Blue Star/ VOLTAS/DAIKIN/ CARRIER/MITHIBUSHI/O General Make Split AC 1.8 Ton individual indoor and outdoor units for breakdown calls servicing the machine for the entire outdoor and indoor units in regular intervals. The above work includes day to day inspection, regular maintenance such as Indoor, outdoor coil cleaning, filter cleaning, replacement of differnt type of Indoor sensors, filters, IDU/ODU coils materials like Indoor, outdoor fan motors, refrigerant gases, electronic parts such as power contractors, outdoor MCB's and service consumables and regular servicing of equipments etc., complete as directed by the HMWS&SB Engineers for the period of 12 months excluding condensers and Evaporator Coils, replacement of units, copper piping, electrical cabling, Major electronice parts such as Compressors, IDU main PCB. The different types of AC systems annual maintenance and servicing including technicain, labour charges, transportation, loading & unloading charges at Front & Rear administrative building blocks etc., complete as directed by the departmental officers. (Rate as per Lowest quotation/Sanctioned Estimate) Front building located at ground floor Front building located at 1st floor Front building located at 2nd floor Front building located at 3rd floor Front building located at 4th floor Front building located at 5th floor Front building located at 6th floor Rear building located at 5th floor
264
1050
277200
... More
Providing annual maintenance services;Providing annual maintenance to (22)Nos Blue Star/ VOLTAS/DAIKIN/ CARRIER/MITHIBUSHI/O General Make Split AC 1.5 Ton individual indoor and outdoor units for breakdown calls servicing the machine for the entire outdoor and indoor units in regular intervals. The above work includes day to day inspection, regular maintenance such as Indoor, outdoor coil cleaning, filter cleaning, replacement of differnt type of Indoor sensors, filters, IDU/ODU coils materials like Indoor, outdoor fan motors, refrigerant gases, electronic parts such as power contractors, outdoor MCB's and service consumables and regular servicing of equipments etc., complete as directed by the HMWS&SB Engineers for the period of 12 months excluding condensers and Evaporator Coils, replacement of units, copper piping, electrical cabling, Major electronice parts such as Compressors, IDU main PCB. The different types of AC systems annual maintenance and servicing including technicain, labour charges, transportation, loading & unloading charges at Front & Rear administrative building blocks etc., complete as directed by the departmental officers. (Rate as per Lowest quotation/Sanctioned Estimate) Front building located at ground floor Front building located at 1st floor Front building located at 2nd floor Front building located at 3rd floor Front building located at 4th floor Rear building located at ground floor Rear building located at 5th floor Rear building located at 6th floor (Call center) Theme Park located at 51 Jubilee Hills
264
885
233640
... More
Providing annual maintenance services;Providing overall servicing to (16)Nos of 4.0 Ton BVRF/IVRF Cassette Indoor AC units by chemical cleaning for every 12 months of entire idu unit, air blowers, mother board along with all electrical connections & cleaning checking and water service and overall testing at full load with necessary consumbales such as indoor sensors, control cabling, fanmotor and Blower and drain pump of Indoor unit and Fan motor etc suitable to existing cassette Type indoors at various chambers/cabins at front block complete as with necessary skilled technician charges etc,complete as directed by the departmental officers. (Rate as per Lowest quotation/Sanctioned Estimate) Front building Located at ground floor Front building Located at 1st floor Front building Located at 3rd floor Front building Located at 5th floor Front building Located at 6th floor
16
4350
69600
... More
Providing annual maintenance services;Providing overall servicing to (16)Nos of 3.8 Ton BVRF/IVRF Cassette Indoor AC units by chemical cleaning for every 12 months of entire idu unit, air blowers, mother board along with all electrical connections & cleaning checking and water service and overall testing at full load with necessary consumbales such as indoor sensors, control cabling, fanmotor and Blower and drain pump of Indoor unit and Fan motor etc suitable to existing cassette Type indoors at various chambers/cabins at front block complete as with necessary skilled technician charges etc,complete as directed by the departmental officers.(Rate as per Lowest quotation/Sanctioned Estimate) Front building Located at 1st floor Front building Located at 2nd floor Front building Located at 3rd floor Front building Located at 4th floor Front building Located at 5th floor
16
3750
60000
... More
Providing annual maintenance services;Providing overall servicing to (13)Nos of 2.8 Ton BVRF/IVRF Cassette Indoor AC units by chemical cleaning for every 12 months of entire idu unit, air blowers, mother board along with all electrical connections & cleaning checking and water service and overall testing at full load with necessary consumbales such as indoor sensors, control cabling, fanmotor and Blower and drain pump of Indoor unit and Fan motor etc suitable to existing cassette Type indoors at various chambers/cabins at front block complete as with necessary skilled technician charges etc,complete as directed by the departmental officers. (Rate as per Lowest quotation/Sanctioned Estimate) Front building Located at 1st floor Front building Located at 2nd floor Front building Located at 3rd floor Front building Located at 4th floor Front building Located at 5th floor
13
2750
35750
... More
Providing annual maintenance services;Providing overall servicing to (12)Nos of 2.0 Ton BVRF/IVRF Cassette Indoor AC units by chemical cleaning for every 12 months of entire idu unit, air blowers, mother board along with all electrical connections & cleaning checking and water service and overall testing at full load with necessary consumbales such as indoor sensors, control cabling, fanmotor and Blower and drain pump of Indoor unit and Fan motor etc suitable to existing cassette Type indoors at various chambers/cabins at front block complete as with necessary skilled technician charges etc,complete as directed by the departmental officers. (Rate as per Lowest quotation/Sanctioned Estimate) Front building Located at 1st floor Front building Located at 2nd floor Front building Located at 3rd floor Front building Located at 4th floor Front building Located at 5th floor
12
2450
29400
... More
Providing annual maintenance services;Engaging of Skilled Technician/Electrician for attending the day to day complaints for a period of one year of HVAC IVRF/VRF, Non VRF, Split Ac units in the administrative (front & Rear Blocks) of HMWS&SB. The work includes operation and Maintenance of AC units regular checking of 3 Phase power supply distribution system(MCB?s, Switch boards, Individual control panel cleaning and Maintenance) and including cost and conveyance, labour charges etc,complete as directed by the departmental officers. (As per SSR:2023-24)
12
23010
276120
... More
Providing annual maintenance services;Supply, Delivery, installation & testing of new 6 HP Fixed Oil Compressor unit sutible for the 12/18 TCE(HP)Outdoor compressor unit of BVRF AC system , having Specifications of 3 phase , 415V ,50Hz, 1.69 Lit capasity pumping pressure of 16.2Cum/hr with a pressure of 43.0/28.0 H/L , bars with referegerent of R-410a in place of damaged and unserveceble duly disconnicting the inlet and outlet copper pipeing in the odu , along with all electrical connections & checking and re filling of Full gas charging and testing on no load , Full load and after deducting cost of materials etc,complete as directed by the departmental officers. (Rate as per Lowest quotation/Sanctioned Estimate)
2
83000
166000
... More
Providing annual maintenance services;Supply, Delivery, installation & testing of new 7HP Fixed Oil Compressor unit sutible for the 21TCE(HP)Outdoor compressor unit of BVRF AC system,having Specifications of 3 phase, 415V,50Hz,1.69 Lit capasity pumping pressure of 16.2Cum/hr with a pressure of 43.0/28.0 H/L,bars with referegerent of R-410a in place of damaged and unserveceble duly disconnicting the inlet and outlet copperpipeing in the odu, along with all electrical connections & checking and re filling of Full gas charging and testing on no load,Full load and after deducting cost of materials etc,complete as directed by the departmental officers.(Rate as per Lowest quotation/Sanctioned Estimate)
2
89500
179000
... More
Providing annual maintenance services;Supply, Delivery, installation & testing of new 3B Controller (fan speed controller) of Bluestar Make for Out Door Compressor unit suitable for 12/18/21TCE,3Phase to single phase convert,inplace of burntout & unservicable of Front admin building block,1 year warranty including testing, transportation,cost conveyance and after deducting cost of materials etc,complete as directed by the departmental officers. (Rate as per Lowest quotation/Sanctioned Estimate)
5
42000
210000
... More
Providing annual maintenance services;Supply, Delivery, installation & testing of new Helical oil separator of emerson make having specitions of Internel volume of 3.4 Litrs,MWP 40 Br sutiable R134a,R22,R410a in place of damaged and unserveceble duly disconnicting the inlet and out let copperpipeing in the 12/18/21TCE,along with all electrical connections &checking and re filling of Full gas charging and testing on no load, Full load and after deducting cost of materials etc,complete as directed by the departmental officers. (Rate as per Lowest quotation/ Sanctioned Estimate)
1
45000
45000
... More
Providing annual maintenance services;Supply,Delivery, installation & testing of new micro processor based PCB unit of Blue Star Make for Out Door compressor unit suitable to BVRF/IVRF of 12/16/18/21 TCE inplace of burntout & unservicable of Front admin building block with software loading & 1 year warranty of PCB board including testing, transportation,cost conveyance and after deducting cost of materials etc,complete as directed by the departmental officers. (Rate as per Lowest quotation/Sanctioned Estimate)
8
76500
612000
... More
Providing annual maintenance services;Supply,Delivery, installation & testing of new micro processor based PCB for indoor cassette ac suitable to BVRF/IVRF of 2.0/2.8/3.8/4.0 Ton inplace of burntout & unservicable at Front admin building block with software loading & 1 year warranty of PCB board including testing,transportation,cost conveyance and after deducting cost of materials etc,complete as directed by the departmental officers. (Rate as per Lowest quotation/Sanctioned Estimate)
6
13200
79200