For getting the details of etenders, if you are looking for information about them from the cumbersome government websites but are tired of doing so, Bidassist comes up with a one stop solution. It collates every Eproc telangana tender on Bidassist. One can approach it for the bidding process, registration process, etc., are explained below.

Hyderabad Metropolitan Water Supply And Sewerage Board - HMWSSB Tender

Works
Electrical Generators And Transformers
Electrical and Electronics
Opening Date24 Mar 2025
Closing Date2 Apr 2025
Tender Amount₹ 1,55,10,580 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Transportation, erection, testing and commissioning of 33/6.6 KV electrical substation including exi;110 V, 25 A Battery Charger and allied equipment.

1

9800

9800

... More
Transportation, erection, testing and commissioning of 33/6.6 KV electrical substation including exi;6.6 KV, 1250 A VCB panels and allied equipment.

5

9850

49250

... More
Transportation, erection, testing and commissioning of 33/6.6 KV electrical substation including exi;Bus Capacitor banks, Motor feeder capacitor banks and allied equipment.

13

4850

63050

... More
Transportation, erection, testing and commissioning of 33/6.6 KV electrical substation including exi;Soft starters and allied equipment.(220KW & 450 KW)

10

14950

149500

... More
Transportation, erection, testing and commissioning of 33/6.6 KV electrical substation including exi;6.6 KV, 220 KW Motors and allied equipment

5

19750

98750

... More
Transportation, erection, testing and commissioning of 33/6.6 KV electrical substation including exi;33KV, 100 Sqmm OH Conductor and allied equipment

15000

45

675000

... More
Transportation, erection, testing and commissioning of 33/6.6 KV electrical substation including exi;33KV cables and 6.6 KV cables and allied equipment

1

48750

48750

... More
Transportation, erection, testing and commissioning of 33/6.6 KV electrical substation including exi;LT panel boards and allied equipment

1

18750

18750

... More
Transportation, erection, testing and commissioning of 33/6.6 KV electrical substation including exi;33KV, VCB panel Kiosks and allied equipment

5

23500

117500

... More
Transportation, erection, testing and commissioning of 33/6.6 KV electrical substation including exi;300 Sqmm cables and 1100V cables and allied equipment

1

46500

46500

... More
Transportation, erection, testing and commissioning of 33/6.6 KV electrical substation including exi;LBS panel Kiosks and allied equipment

4

18750

75000

... More
Transportation, erection, testing and commissioning of 33/6.6 KV electrical substation including exi;6.6 KV/433, 3.15 MVA Power transformers and allied equipment

2

92700

185400

... More
Transportation, erection, testing and commissioning of 33/6.6 KV electrical substation including exi;33KV/430 V, 50 KVA Auxiliary transformers and allied equipment

1

14650

14650

... More
Transportation, erection, testing and commissioning of 33/6.6 KV electrical substation including exi;Dismantling, removing, Loading, transporting and Unloading at safe place all the major Sub station equipment like Power transformers and Panels, cables, pumps, starters, including, all electrical items etc., complete, when the water level rises above +510.00 ft to avoid submergence including cost of the hire and operational charges of all the equipment such as trucks, trailers, cranes etc., and cost of skilled and unskilled labour etc requires for such lifting and transporting the major Substation arrangements to safer place i.e., at Godakondla, Nasarlapally & Kodandapur pumping stations and keep the same intact for next re-erection for restoring the temporary pumping once the water level in the Nagarjuna sagar Reservoir falls below +505.00 ft as directed by the departmental officers. 33/6.6 KV, 3.15 MVA Power transformers and allied equipment

2

92700

185400

... More
Transportation, erection, testing and commissioning of 33/6.6 KV electrical substation including exi;Proviosion for preperaration of drawings, approvals from CEIG and other TSSPDCL charges by co ordinating with CEIG and TSSPDCL officials as directed by the departmental officers.

1

148500

148500

... More
Transportation, erection, testing and commissioning of 33/6.6 KV electrical substation including exi;Loading, transportation, unloading, Laying, testing and commissioning of 1100V, 3 C X 300 Sq. mm LT Cables from Transformers to breakers and to soft starters of pumps and accessories as per drawings and specifications. The cost including transportation from Kodandapur, Nasarlapally and Godakondla to Puttamgandi emergency pumping station by providing required cranes, vehicles, required tools, men and material etc., under the supervision of technical persons to avoid damages, transit insurance, all labour charges etc complete as directed by the departmental officers.

750

95

71250

... More
Transportation, erection, testing and commissioning of 33/6.6 KV electrical substation including exi;Loading, transportation, unloading, erection, testing and commissioning of 6.6KV, 630A Load Break switch with earthing provision, out door type, complete as per specification. The cost including transportation from Kodandapur, Nasarlapally and Godakondla to Puttamgandi emergency pumping station by providing required cranes, vehicles, required tools, men and material etc., under the supervision of technical persons to avoid damages, transit insurance, all labour charges etc complete as directed by the departmental officers.

4

9500

38000

... More
Transportation, erection, testing and commissioning of 33/6.6 KV electrical substation including exi;Loading, transportation, unloading, erection, testing and commissioning of Four pole structure material with suitalble poles, 4 nos of 100 mm X 50mm X 6 mm including AB switches with earth switch, lighting arrestors(LA's), including 3 no of LA's structures before transformers, earthing etc all complete as per drawings and specifications at temporary control room as per CEIG norms & Drawing Approvals.The cost including transportation, transit insurance, all labour charges etc including painting complete as directed by the departmental officers.

1

168000

168000

... More
Transportation, erection, testing and commissioning of 33/6.6 KV electrical substation including exi;Engaging labour to remove huge grown up trees all along the 33KV overhead line (5KM approx) alignment to facilitate for stringing the over head conductor as per site condition etc., to avoid earth faults complete as directed by the departmental officers.

80

575

46000

... More
Transportation, erection, testing and commissioning of 33/6.6 KV electrical substation including exi;Supply,delivery, transportation, unloading, erection, testing and commissioning of RCC pole of 9.1 mtr height in place of damaged including the total civil work : Excavation of 1X1X2 mtr depth and concreting of 0.5 X 0.5 X 2 mtr and coping as per standard for 33KV over head line from TSGENCO Substation to 33 KV HMWSSB substation near proposed Pump house (5 KM Approx). including transportation to Puttamgandi complete as directed by the departmental officers .

30

11950

358500

... More
Transportation, erection, testing and commissioning of 33/6.6 KV electrical substation including exi;Loading, transportation, unloading, erection, testing and commissioning of suitable Over head conductor carrying capacity of 100A of 33 KV as per CEIG norms by utilising existing RCC poles from TSSPDCL Substation to HMWSSB substation including all accessories like: cross arms, insulators, LAS, line isolators, stay wires etc.,complete as directed by the departmental officers.

12500

75

937500

... More
Transportation, erection, testing and commissioning of 33/6.6 KV electrical substation including exi;Design, supply, delivery, erection, testing and commissioning of suitable Over head conductor carrying capacity of 100A of 33 KV as per CEIG norms by utilising existing RCC poles from TSSPDCL Substation to HMWSSB substation including all accessories complete as directed by the departmental officers.

2500

254

635000

... More
Transportation, erection, testing and commissioning of 33/6.6 KV electrical substation including exi;Design,manufacture, supply, delivery, erection, testing and commissioning of Fire safety as per specifications and statutory regulations. A) Rubber Matting 2m x 1m-12mm thick (9 Nos), Shock Treatment Chart (2 Nos), Caution and Danger Board (10 Nos), CO2 fire extinguishers 5kg with fixing bracket (5 Nos), 4Nos fire buckets with 1No.bucket stand (2No's).The cost including transportation, transit insurance, all labour charges etc complete as directed by the departmental officers.

1

150000

150000

... More
Transportation, erection, testing and commissioning of 33/6.6 KV electrical substation including exi;25 X 3 mm Cu flat 33 KV LA Earthing(1 kg/Rmt)

90

1100

99000

... More
Transportation, erection, testing and commissioning of 33/6.6 KV electrical substation including exi;50 X 10 mm Cu Flat For Transformers Neutral Earthling(4.65 Kgs/ Rmt)

90

4600

414000

... More
Transportation, erection, testing and commissioning of 33/6.6 KV electrical substation including exi;25 x 6 mm G.I. Flat.

350

190

66500

... More
Transportation, erection, testing and commissioning of 33/6.6 KV electrical substation including exi;50 x 6 mm G.I Flat

300

330

99000

... More
Transportation, erection, testing and commissioning of 33/6.6 KV electrical substation including exi;Supply, delivery, erection, testing and commissioning of Earthing materials. 100 x 10 mm G.I Flat

500

550

275000

... More
Transportation, erection, testing and commissioning of 33/6.6 KV electrical substation including exi;Supply, delivery, Loading, transporting, unloading, laying, testing and commissioning of existing Earthing and lightening protection system as per drawings and specifications and main earthing conductor buried in earth and in floor slabs in building, conductor leads to equipments above ground and lightning protection with providing independent earthling in all soils, using 100 mm NB heavy duty C.I. Pipe electrode of 3.0 Mtrs length with necessary accessories with hume pipe ring duly providing staggered holes including filling with equal proportion of Salt and Charcoal in layers and all labour charges etc., complete and as per I.E rules and specifications as directed by the departmental officers.

15

6200

93000

... More
Transportation, erection, testing and commissioning of 33/6.6 KV electrical substation including exi;Loading, transporting, unloading, laying, testing and commissioning of 6.6 KV, 3 C X 150 Sq. mm/75Sq. mm/90Sq. mm XLPE HT Cables from Transformers Secondary of I & II to 6.6KV incoming panels of pumping station as per drawings and specifications. The cost including transportation from Kodandapur, Nasarlapally and Godakondla to Puttamgandi emergency pumping station by providing required cranes, vehicles, required tools, men and material etc., under the supervision of technical persons to avoid damages, transit insurance, all labour charges etc complete as directed by the departmental officers.

350

175

61250

... More
Transportation, erection, testing and commissioning of 33/6.6 KV electrical substation including exi;Loading, transporting, unloading, laying, testing and commissioning of 33 KV, 3 C X 150 Sq. mm XLPE HT Cables from Four pole structure to Incoming panel and out going panel to Transformer No. I&II Transformers as per drawings and specifications. The cost including transportation from Kodandapur, Nasarlapally and Godakondla to Puttamgandi emergency pumping station by providing required cranes, vehicles, required tools, men and material etc., under the supervision of technical persons to avoid damages, transit insurance, all labour charges etc complete as directed by the departmental officers.

100

385

38500

... More
Transportation, erection, testing and commissioning of 33/6.6 KV electrical substation including exi;Loading, transportation, erection, testing and commissioning of existing 6.6 KV Motor capacitor banks and Bus capacitors Banks work should carried out with out interrupting the pumping system the cost including transportation from Godakondla to Puttamgandi emergency pumping station by providing required cranes, vehicles, required tools, men and material etc., under the supervision of technical persons to avoid damages, transit insurance, all labour charges etc complete as directed by the departmental officers.

13

9850

128050

... More
Transportation, erection, testing and commissioning of 33/6.6 KV electrical substation including exi;Loading, transportation, unloading, Erection, testing and commissioning of Main lighting distribution boards at substation and pump house for indoor areas with Incomer - 1No.- 125A MCCB with ELCB- 4pole and outgoings - 16 Nos 6A MCB, SPN, 16 Nos 10A MCB, SPN as per approved drawing. The cost including transportation, transit insurance, all labour charges etc complete as directed by the departmental officers.

2

6950

13900

... More
Transportation, erection, testing and commissioning of 33/6.6 KV electrical substation including exi;Loading, transportation, unloading, Erection, testing and commissioning of existing Soft starters suitable for 415V 450 KW/600 HP Pump sets with metering, protection, accessories complete housed in painted sheet metal enclouser and all other incidental operational charges etc., the cost including transportation from Godakondla to Puttamgandi emergency pumping station by providing required cranes, vehicles, required tools, men and material etc., under the supervision of technical persons to avoid damages, transit insurance, all labour charges etc complete as directed by the departmental officers.

5

15000

75000

... More
Transportation, erection, testing and commissioning of 33/6.6 KV electrical substation including exi;Loading, transportation, unloading, erection, testing and commissioning of 6.6KV existing soft starters for 6.6KV, 220KW motors. The electrical protection system shall be as per IE rules and relevant IS, the cost including transportation from Godakondla to Puttamgandi emergency pumping station by providing required cranes, vehicles, required tools, men and material etc., under the supervision of technical persons to avoid damages, transit insurance, all labour charges etc complete as directed by the departmental officers.

5

14500

72500

... More
Transportation, erection, testing and commissioning of 33/6.6 KV electrical substation including exi;Loading, transportation, modification, erection, testing and commissioning of 6.6KV existing 5 No's electrical Panel boards i.e,6.6 KV 1250 A,.in and out panels for motor feeders.The cost including transportation from Nasarlapally to Puttamgandi emergency pumping station by providing required cranes, vehicles, required tools, men and material etc., under the supervision of technical persons to avoid damages, transit insurance, all labour charges etc complete as directed by the departmental officers.

5

15000

75000

... More
Transportation, erection, testing and commissioning of 33/6.6 KV electrical substation including exi;Loading, transportation, unloading, erection, testing and commissioning of Alsthom make, 6.6KV, 220KW motors by providing required Electro-mechanical technical persons, tools and required testing equipment including the cost including transportation from Kodandapur to Puttamgandi emergency pumping station by providing required cranes, vehicles, required tools, men and material etc., under the supervision of technical persons to avoid damages, transit insurance, all labour charges etc complete as directed by the departmental officers.

5

24500

122500

... More
Transportation, erection, testing and commissioning of 33/6.6 KV electrical substation including exi;Loading, transportation, unloading, erection, testing and commissioning of existing out door panels 33 KV, 1250 A, 25 KA, VCBs with CT's, PT's, protection relays(including UV, O/C & Differential etc., including control and relay provisions as per IE standards and necessary connections, mounting on CC bed and other standard items and internal wiring etc., including lighting arrestors(LA's) installation before transformers as per suitable rating complete as per approved drawings by department and CEIG and the cost including transportation from Nasarlapally to Puttamgandi emergency pumping station by providing required cranes, vehicles, required tools, men and material etc., under the supervision of technical persons to avoid damages, transit insurance, all labour charges etc complete as directed by the departmental officers.

4

25000

100000

... More
Transportation, erection, testing and commissioning of 33/6.6 KV electrical substation including exi;Loading, transportation, unloading, erection, testing and commissioning of existing 3150 KVA or 3.15MVA 6.6 KV/433V, DYN 11 / ONAN, Copper wound transformer, out door type, plinth mounted, oil cooled type, drying the core and winding for improving the IR values filling with existing and new oil duly filtering with oil filteration machine at site, testing and commissioning with standard fixing of terminal boxes, plates, Gass operated relay, off load tap changer, necessary connections, two earthing terminals, complete as per specification. The cost including transportation from Nasarlapally to Puttamgandi emergency pumping station by providing required cranes, vehicles, required tools, men and material etc., under the supervision of technical persons to avoid damages, transit insurance, all labour charges etc complete as directed by the departmental officers.

2

215000

430000

... More
Transportation, erection, testing and commissioning of 33/6.6 KV electrical substation including exi;Loading, transportation, unloading, Erection, testing and commissioning of existing 50 KVA - 33 KV/ 433 V, DYN11 / ONAN, Copper wound transformer, out door type, plinth mounted, oil cooled type, drying the core and winding for improving the IR values filling with existing and new oil duly filtering with oil filteration machine at site,testing and commissioning with standard fittings such as rated and terminal making plates, tap changer from +5% to -5%, two earthing terminals, etc., complete as per specification. The cost including transportation from Godakondla to Puttamgandi emergency pumping station by providing required cranes, vehicles, required tools, men and material etc., under the supervision of technical persons to avoid damages, transit insurance, all labour charges etc complete as directed by the departmental officers.

1

15000

15000

... More
Transportation, erection, testing and commissioning of 33/6.6 KV electrical substation including exi;Loading, transportation, unloading, Erection, testing and commissioning of existing 33KV / 6.6 KV power transformers (3.15MVA), out door type, plinth mounted, oil cooled type, drying the core and winding for improving the IR values filling with existing and new oil duly filtering with oil filteration machine at site, testing and commissioning with standard and fixing the terminal boxes and plates, Gass operated relay, OLTC control panel includes the AVR (Auto voltage regulator) panel, necessary connections of all radiators, \ earthing terminals, and etc., complete as per specification. The cost including transportation from Kodandapur to Puttamgandi emergency pumping station by providing required cranes, vehicles, required tools, men and material etc., under the supervision of technical persons to avoid damages, transit insurance, all labour charges etc complete as directed by the departmental officers.

2

215000

430000

... More
Transportation, erection, testing and commissioning of 33/6.6 KV electrical substation including exi;Servicing / overhauling, Loading, transportation, unloading, erection, testing and commissioning of electrically operated 10T Capacity (E.O.T. Crane) for movement in all direction such as horizantal and vertical which is to be installed in the Puttamgandi for erection, assembly, and Maintenance of Pump sets and the cost including transportation, transit insurance, all labour charges etc complete as per requirement as directed by the department officers.

1

128500

128500

... More
Transportation, erection, testing and commissioning of 33/6.6 KV electrical substation including exi;Supply and delivery of suitable straight joint kits of 1100V, 3 C X 300 Sq. mm LT armoured Cables out door type, the cost including transportation to Kodandapur, labour charges etc complete as directed by the departmental officers.

10

9250

92500

... More
Transportation, erection, testing and commissioning of 33/6.6 KV electrical substation including exi;Supply and delivery of 1100V, 3 C X 300 Sq. mm LT Armoured Aluminium Cable for laying in place of failure and burnt out cable from 6.6KV/433V Transformers to LT soft starters of 600HP pumps.The cost including cost of transportation to Kodandapur, labour etc complete as directed by the departmental officers.

250

2150

537500

... More
Transportation, erection, testing and commissioning of 33/6.6 KV electrical substation including exi;Supply, termination, testing and commissioning of 33KV, end termination kits of 3 C X 150 Sq. mm XLPE HT Cables suitable terminations Kits out door type and accessories as per drawings and specifications, the cost including transportation to Kodandapur, all labour charges etc complete as directed by the departmental officers.

6

16800

100800

... More
Transportation, erection, testing and commissioning of 33/6.6 KV electrical substation including exi;Supply, termination, testing and commissioning of 6.6 KV, end termination kits of 3 C X70 Sq. mm XLPE HT Cables suitable terminations Kits indoor type and accessories as per drawings and specifications.The cost including transportation to Kodandapur, all labour charges etc complete as directed by the departmental officers.

6

11000

66000

... More
Transportation, erection, testing and commissioning of 33/6.6 KV electrical substation including exi;Supply, termination, testing and commissioning of 6.6 KV, end termination kits of 3 C X 95 Sq. mm XLPE HT Cables suitable terminations Kits indoor type and accessories as per drawings and specifications.The cost including transportation to Kodandapur, all labour charges etc complete as directed by the departmental officers.

10

12500

125000

... More
Transportation, erection, testing and commissioning of 33/6.6 KV electrical substation including exi;Supply, termination, testing and commissioning of 6.6 KV, end termination kits of 3 C X 150 Sq. mm XLPE HT Cables suitable terminations Kits indoor type and accessories as per drawings and specifications.The cost including transportation to Kodandapur, all labour charges etc complete as directed by the departmental officers.

20

13500

270000

... More
Transportation, erection, testing and commissioning of 33/6.6 KV electrical substation including exi;Supply and transportation of 90W +/-10% (>=9000 Lumens) LED Street light Body made of high grade pressure die ? cast Aluminium alloy with corrosion resistant powder coat, having protective toughened glass cover, Suitable lens on LEDs, Less Glare, IP 66 (Silicon gasket ensures Optical & Electrical compartments are IP 66) protected, wide operating voltage range, P.F > 0.90, System having efficacy >110 lumens/watt, with Ingress protection IP66, Potted driver, Driver surge protection >10KV, THD<15%, CCT: 3000- 6500K as desired by the department and as per IS, CRI>70, Inbuilt Electrical protections like Over voltage, short circuit, Over load, Open Circuit, Miswiring, etc complete with BIS certification with 5 years warranty. The contractor has to furnish the manufacturer warranty letter, LM 79 and LM 80 certificates. LUMINAIRE MAKE : PHILIPS / OSRAM / GE Venture / CROMPTON / BAJAJ / Surya / Wipro / Jaquar / Eveready / Halonix / Keselec / HAVELLS / POLYCAB / SURYA / SYSKA / Capart / Fortune Arrt / FIEM /Panasonic / Arraystorm / GM / Goldmedal / Silicon / Leksa / Orient / HPL / Valmont Transrail LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA / OSRAM / SAMSUNG / LG LED, inclduing transportation to Kodandapur complete as directed by the departmental officers.(SSR 2023-24)

20

6480

129600

... More
Transportation, erection, testing and commissioning of 33/6.6 KV electrical substation including exi;Supply, delivery, Erection, testing and commissioning of 110V DC, 100 AH, battery bank of HBL/EXIDE/AMCO or equivalent make with all accessories including charging & discharging as per standard, testing & commissioning of battery bank inclduing transportation to Kodandapur complete as directed by the departmental officers.

1

485000

485000

... More
Transportation, erection, testing and commissioning of 33/6.6 KV electrical substation including exi;Designing, Manufacturing, Supply, delivery, Erection, testing and commissioning of 110V D.C , 25 A Battery Charger and DC Distribution Board with ammeter and voltmeter inclduing transportation to Kodandapur as per approved drawings and specifications as directed by the departmental officers.

1

152500

152500

... More
Transportation, erection, testing and commissioning of 33/6.6 KV electrical substation including exi;Supply and delivery of 4 core, 2.5 sq.mm flexible copper cables for auxilary power cables, the cost including transportation to Kodandapur and complete as per requirement and as directed by the departmental officers.

250

200

50000

... More
Transportation, erection, testing and commissioning of 33/6.6 KV electrical substation including exi;Supply and delivery of 10 core, 1 sq.mm flexible copper cables for auxilary control cables, the cost including transportation to Kodandapur and complete as per requirement and as directed by the departmental officers.

150

250

37500

... More
Transportation, erection, testing and commissioning of 33/6.6 KV electrical substation including exi;Supply and delivery 33KV, 3 core,150Sq.mm Aluminium armoured cables from four pole structure to 33KV panels to keep ready for erection inclduing transportation to Kodandapur as and required as directed by the departmental officers.

100

1850

185000

... More
Transportation, erection, testing and commissioning of 33/6.6 KV electrical substation including exi;Supply and delivery of 6.6KV,3 core, 150 Sq.mm Aluminium armoured cables from 6.6KV transformers to motor feeders, to keep ready for erection inclduing transportation to Kodandapur as and required as directed by the departmental officers.

150

1500

225000

... More
Transportation, erection, testing and commissioning of 33/6.6 KV electrical substation including exi;Supply and delivery of 1100V, 4 core, 50Sq.mm flexible copper cable for 415V 600HP submersible pumpsets, to keep ready for erection inclduing transportation to Kodandapur as and required as directed by the departmental officers.

250

3820

955000

... More
Transportation, erection, testing and commissioning of 33/6.6 KV electrical substation including exi;Supply of 200KVAR 3 Pole 6.6KV capacitors to keep ready for erection inclduing transportation to Kodandapur as and required as directed by the departmental officers.

2

79000

158000

... More
Transportation, erection, testing and commissioning of 33/6.6 KV electrical substation including exi;Supply and delivery of 140KVAR, 3 pole, 6.6KV capacitors to keep ready for erection inclduing transportation to Kodandapur as and required as directed by the departmental officers.

11

55300

608300

... More
Transportation, erection, testing and commissioning of 33/6.6 KV electrical substation including exi;Servicing/Overhauling of HT motor soft starter duly servicing all auxiliary contactors and timers and testing of all control wiring with no load, to keep ready for erection as and required as directed by the departmental officers.

5

15000

75000

... More
Transportation, erection, testing and commissioning of 33/6.6 KV electrical substation including exi;Repairing, servicing/overhauling of LT 415V soft starters of 600HP pumpsets duly servicing Air circuit breakers 800/1000A and testing of all control wiring with no load to keep ready for erection as and required as directed by the departmental officers.

5

15000

75000

... More
Transportation, erection, testing and commissioning of 33/6.6 KV electrical substation including exi;Repairing and Servicing of 6.6KV LBS to keep the LBS in 'ready to fix condition', to erect as and when required at Puttamgandi emergency pumping station, complete as per requirement as directed by the departmental officers.

4

10000

40000

... More
Transportation, erection, testing and commissioning of 33/6.6 KV electrical substation including exi;Supply and delivery of 6.6KV 400Amps Vaccume contactors for 6.6KV soft starters as per old sample inclduing transportation to Kodandapur complete as directed by the departmental officers.

3

185000

555000

... More
Transportation, erection, testing and commissioning of 33/6.6 KV electrical substation including exi;Repairing, Servicing/overhauling and testing of existing out door 6.6 KV, 1250 A VCB motor feeders with CT's, PT's, protection relays by providing new bus bars in the panels if any required as per old sample by engaging required cranes, vehicles, tools, men and material etc., under the supervision of technical personsto keep the breakers in 'ready to fix condition', to erect as and when required at Puttamgandi emergency pumping station, complete as per requirement as directed by the departmental officers.

5

35000

175000

... More
Transportation, erection, testing and commissioning of 33/6.6 KV electrical substation including exi;Repairing, Servicing/overhauling and testing of existing out door 33 KV, 1250 A, 25 KA, VCBs with CT's, PT's, protection relays by providing new bus bars in the panels if any required as per old sample by engaging required cranes, vehicles, tools, men and material etc., under the supervision of technical persons at Puttamgandi, to keep the Breakers in 'ready to fix condition', to erect as and when required at Puttamgandi emergency pumping station, complete as per requirement as directed by the departmental officers.

1

49500

49500

... More
Transportation, erection, testing and commissioning of 33/6.6 KV electrical substation including exi;Repairing, Servicing/overhauling and testing of existing out door 33 KV, 1250 A, 25 KA, VCBs with CT's, PT's, protection relays by providing new bus bars in the panels if any required as per old sample by engaging required cranes, vehicles, tools, men and material etc., under the supervision of technical persons at Nasarlapally, to keep the Breakers in 'ready to fix condition', to erect as and when required at Puttamgandi emergency pumping station, complete as per requirement as directed by the departmental officers.

4

49500

198000

... More
Transportation, erection, testing and commissioning of 33/6.6 KV electrical substation including exi;Supply and delivery of transformer oil tested as per IS-335-1972 including transportation all labour charges etc. complete as directed by the departmental officers.

5220

148

772560

... More
Transportation, erection, testing and commissioning of 33/6.6 KV electrical substation including exi;Repairing/ Overhauling of existing 33KV / 433 V (50KVA), out door type, oil cooled type power transformer duly filtering transformer oil with oil filtration machine and fixing the terminal boxes and plates, providing new silica gel breathers by testing of transformer by performing all standerd tests by enaging of required cranes, technical persons, tools and material, Painting etc., at Godakondla to keep transformer in 'ready to fix condition', to erect as and when required at Puttamgandi emergency pumping station complete as per requirement as directed by the departmental officers.

1

45000

45000

... More
Transportation, erection, testing and commissioning of 33/6.6 KV electrical substation including exi;Repairing/ Overhauling of existing 6.6KV / 433V (3.15MVA), out door type, oil cooled type power transformers duly untanking oil and core assembly, varnishing and ovening of core assembly duly testing IR values and tanking of core assembly,replacing all gaskets/beedings,replacement of radiator valves with new, filling of filtered transformer oil with oil filtration machine and fixing the terminal boxes and plates, necessary connections of all radiators, including repairing of damaged existing radiators, providing new silica gel breathers and also testing of transformer by performing all standerd tests at work shop by enaging required cranes ,vehicles, technical persons, tools and material etc., including painting, transportation to and fro between work shop and Nasarlapally site premises to keep the Power Transformers in 'ready to fix condition', to erect as and when required at Puttamgandi emergency pumping station, complete as per requirement as directed by the departmental officers.

2

275000

550000

... More
Transportation, erection, testing and commissioning of 33/6.6 KV electrical substation including exi;Repairing/ Overhauling of existing 33KV / 6.6 KV (3.15MVA), out door type, oil cooled type power transformers duly untanking oil and core assembly, varnishing and ovening of core assembly duly testing IR values and tanking of core assembly,replacing all gaskets/beedings,replacement of radiator valves with new, filling of filtered transformer oil with oil filtration machine and fixing the terminal boxes and plates, necessary connections of all radiators, including repairing of damaged existing radiators, providing new silica gel breathers and also testing of transformer by performing all standerd tests at work shop by enaging required cranes ,vehicles, technical persons, tools and material etc., including painting, transportation to and fro between work shop and Kodandapur site premises to keep the Power Transformers in 'ready to fix condition', to erect as and when required at Puttamgandi emergency pumping station, complete as per requirement as directed by the departmental officers.

2

275000

550000



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.