Bharat Sanchar Nigam Limited Tender
... More
For getting the details of etenders, if you are looking for information about them from the cumbersome government websites but are tired of doing so, Bidassist comes up with a one stop solution. It collates every Eproc telangana tender on Bidassist. One can approach it for the bidding process, registration process, etc., are explained below.
Costs
EMD
₹ 6,305Document Cost
₹ 590Tender Fee
Refer Documents
Summary
Attending Lt Breakdown Maintenance Works Sr Gm Area-ii
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_BSNL_175301_1Bid Award Id
ViewTender No
49/BEDH-II/2023-24Tender Authority
Bharat Sanchar Nigam Limited ViewPurchaser Address
-Website
http://https://www.bsnl.co.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Supplying and crimping of 16Sqmm lugs for the exisitng 4 core aluminium cable, providing insulation tape etc as required.
4
-
-
... More
(d) 5A sockets (Screw type)
4
-
-
... More
Shifting of change over switch with box from BSNL Bhawan to Karwan TE including fixing the same in suitable location as per engineer incharge instructions.
1
-
-
... More
(e) 50mm dia brass foot valve (make: Zoloto / Leader / SS )
7
-
-
... More
(h) 50mm dia coupling CPVC (Make: Ashirwad / Sudhakar)
6
-
-
... More
Supplying and fixing of 4way MS encloser along with fixing of existing isolator with connecting of existing power plant cable etc
1
-
-
... More
(m) PVC Angle Holders
1
-
-
... More
(b) 18/20 W LED tube light
8
-
-
... More
Dismantling and re-fixing of existing CT operated meter box including removing of incomming and out going cables connections and testing etc.
1
-
-
... More
(b) 40mm dia gi 4" nipple
2
-
-
... More
(c) 36watts Led street light
8
-
-
... More
Supplying and fixing of out door type with rain shade, canopy MS Box suitable for mounting the 100A kit kat fuses, neutral link with locking arrangment etc.,
1
-
-
... More
Attending of emergency breakdown calls from the quarters/ TE bldgs, related to power supply/ water supply pumps/ Compound lights etc, rectifying of fault, disconnecting of faulty/ burnt electrical accessories and restoration of power supply in panel/ DB to pump set by making temporary connections wherever necessary etc., complete as required.
25
-
-
... More
Removing and re-fixing of existing earth bus bar from the surface of wall along with suitable insulators etc.,
1
-
-
... More
(f) 50mm dia 'L' bend CPVC (Make: Ashirwad / Sudhakar)
3
-
-
... More
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required
a) 3 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire
10
-
-
... More
(p) 15A power plug with PVC box
1
-
-
... More
Checking of power supply in the compound lighting pole box with lamp from pole to pole, attending to minor falults etc as required (for 23 poles)
1
-
-
... More
Removing and refixing of fire alarm panel including re-routing the cable etc, providing interconnections etc.
1
-
-
... More
Removing of exisiting LT Panel including removing of input and out put cables, earthing stip, refixing the same at new location etc.
1
-
-
... More
Disconnecting the power cable of size 3.5x95 sqmm from the alternator, removing the cable from the control panel and MV panel to the change over switch etc.,
35
-
-
... More
Removing of service cable from pole to meter box of size 4x16 sq mm. AUG cable
30
-
-
... More
Rewinding the existing 5HP motor with enamelled copper wire, removing all the burnt copper wires, providing insulating papers in between, providing varnish/ insulation coating on the new winding, oven heating the stator, fixing the same, providing new bearings, greasing etc., checking the shaft/ rotor part for any bends and making good the same if required etc
2
-
-
... More
(o) Calling Bell
1
-
-
... More
(g) 10" x 8" hylam sheet 2mm thick
1
-
-
... More
(q) 63A HRC fuses
3
-
-
... More
Supplying and fixing of following plumbling accessories suitable for the existing motors etc.
(a) 40mm dia GI bends
2
-
-
... More
Supplying and laying of 2 x 6 sqmm weather proof aluminium wire for extending power supply to the pump room panel including testing providing interconnections etc as required.
90
-
-
... More
Repairing of ceiling fan/ exhaust including rewinding and replacement of bearings capacitor and refixing the fan etc., as required.
3
-
-
... More
(c) 40mm dia GI 12" nipple
2
-
-
... More
Laying of recovered cable size upto 95sq.mm on surface of wall including providing clamps making good etc
80
-
-
... More
(d) 50mm CPVC pipe (Make: Ashirwad / Sudhakar)
9
-
-
... More
(g) 50mm dia MABT (Make: Ashirwad / Sudhakar)
6
-
-
... More
Supplying and laying of 8SWG GI wire for loop earthing.
40
-
-
... More
(b) 3.5x25 sq mm
8
-
-
... More
Dismantling of the faulty centrifugal pump set, removing the foundation bolts, packing etc, hiring vehicle for shifting the same to the workshop, shifting back to the site, fixing the new gaskets, foundation bolts, reconnecting the pipe lines etc.,
2
-
-
... More
Supplying and fixing of following electrical accessories suitable for operation on 230volts, 1 phase, 50Hz AC supply including providing interconnections etc as required.
(a) 5A 3pin top
1
-
-
... More
(s) 100A kit kat fuse 1 set (3Nos) with 100 amps neutral link
1
-
-
... More
(f) 15A socket with hylam sheet
1
-
-
... More
(j) 32A SPN MCB
1
-
-
... More
(u) New motor starter 5HP capacity with OL protection, capacitor, SPP, voltmeter, ammeter (Make: GELCO)
1
-
-
... More
(r) 63A kit kat fuse 1 set (3Nos) with 63amps neutral link
2
-
-
... More
(k) 63A 4P isolator
4
-
-
... More
(n) PVC Ceiling rose
1
-
-
... More
Supplying and making of following end terminations with brass compression glands, and lugs as required
(a) 4x16 sq mm
2
-
-
... More
(l) Ceiling fan regulators step type/ dimmer socket type
5
-
-
... More
(i) 6A SP MCB
1
-
-
... More
Dismantling and re-fixing of existing fuses, lightning arrester and capacitor box including removing of cable connections and testing etc.,
1
-
-
... More
Removing and re installation of existing 30 KVA AVR including relaying of cable providing inter connections etc
1
-
-
... More
Supplying and laying of 25x5 mm thick GI Strip from earth pits to busbar etc
10
-
-
... More
(h) 12" x 10" hylam sheet 2mm thick
1
-
-
... More
Supplying and laying of 2x1.5 sqmm copper flexible wire for extending power supply from pole box to street light fitting including testing providing interconnections etc as required.
25
-
-
... More
Removing of lighting DB, DC DB, 63 A TPN Switch Box, with conduits wiring, 3No 18" exhaust fans, celing fans 2 no, etc
1
-
-
... More
(t) Repair of DOL starter
1
-
-