Bharat Sanchar Nigam Limited Tender
For getting the details of etenders, if you are looking for information about them from the cumbersome government websites but are tired of doing so, Bidassist comes up with a one stop solution. It collates every Eproc telangana tender on Bidassist. One can approach it for the bidding process, registration process, etc., are explained below.
Bharat Sanchar Nigam Limited - BSNL Tender
Civil And Construction
Civil Works Others
Building Construction
Eprocure
Opening Date7 Nov 2024
Closing Date16 Nov 2024
Tender Amount₹ 5,04,486
Costs
EMD
₹ 10,100Document Cost
₹ 590Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_BSNL_213726_1Bid Award Id
ViewTender No
NIT No. 62/NIT/CECTSCZ/HYD/2024-25Tender Authority
Bharat Sanchar Nigam Limited ViewPurchaser Address
-Website
http://https://www.bsnl.co.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
1:2:4 (1 Cement : 2 coarse sand derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
0.5
-
-
... More
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :
-
-
-
... More
1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
1
-
-
... More
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III)derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
1
-
-
... More
Centering and shuttering including strutting, propping etc. and removal of form for :
-
-
-
... More
Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like
15
-
-
... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
-
-
-
... More
Thermo-Mechanically Treated bars of grade Fe-500D or more.
300
-
-
... More
Smooth finishing of the exposed surface of R.C.C. work with 6 mm thick cement mortar 1:3 (1 Cement : 3 fine sand).
10
-
-
... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 3.5 in foundation and plinth in:
-
-
-
... More
Cement mortar 1:6 (1 cement : 6 coarse sand)
6
-
-
... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 3.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :
-
-
-
... More
Cement mortar 1:6 (1 cement : 6 coarse sand)
10
-
-
... More
Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :
-
-
-
... More
250x16 mm
2
-
-
... More
Providing and fixing aluminium handles ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete :
-
-
-
... More
100 mm
2
-
-
... More
12 mm cement plaster of mix :
-
-
-
... More
1:6 (1 cement: 6 fine sand)
70
-
-
... More
15 mm cement plaster on the rough side of single or half brick wall of mix :
-
-
-
... More
1:6 (1 cement: 6 fine sand)
70
-
-
... More
Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement.
-
-
-
... More
20 mm cement plaster
225
-
-
... More
Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers.
60
-
-
... More
Finishing walls with Acrylic Smooth exterior paint of required shade :
-
-
-
... More
New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm).
150
-
-
... More
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :
-
-
-
... More
One or more coats on old work.
30
-
-
... More
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground , all complete as per directions of Engineer-In-Charge.
-
-
-
... More
With cement mortar 1:4 (1 cement : 4 fine sand).
25
-
-
... More
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.
-
-
-
... More
In cement mortar
15
-
-
... More
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
225
-
-
... More
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
30
-
-
... More
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately)
-
-
-
... More
30 mm thick
3
-
-
... More
Removal of vegetation at walls/roofs and floors/drainage systems/water supplying stream of the building/over head tanks or at any location and applying any special chemical to defective area to prevent vegetation growth and finishing the same with cement concrete/mortar to match the surface of walls/floors/roofs., etc complete as per the directions of engineer-in-charge(cement concrete/mortar to be paid in separate item.)(Uprooting of vegetation in each location will be measured as one job)
10
-
-
... More
Removing the existing compound wall grill & refixing by making good with necessary welding and straightening the bends/twists square rods, flats etc. The grills shall be fixed in the new proposed holdfasts to suit the existing existing hold fasts. The grills shall be fixed in the proposed compound wall after welding new holdfasts to the old MS grill, by laying CC bed blocks at the position of hold fasts in columns. The MS grills shall be fixed by embedding hold fasts in CC blocks in the proposed compound wall. All complete and as per directions of the Engineer - in - charge.
6
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements