Bharat Sanchar Nigam Limited Tender
For getting the details of etenders, if you are looking for information about them from the cumbersome government websites but are tired of doing so, Bidassist comes up with a one stop solution. It collates every Eproc telangana tender on Bidassist. One can approach it for the bidding process, registration process, etc., are explained below.
Costs
EMD
₹ 11,156Document Cost
₹ 590Tender Fee
Refer Documents
Summary
Repairs To Dtr Accessories, Energy Meter Panel, Cl, Pumpset At S Qtrs Tirumalgiri
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_BSNL_199265_1Bid Award Id
ViewTender No
09/BEDH-II/2024-25 Dated 24-06-2024Tender Authority
Bharat Sanchar Nigam Limited ViewPurchaser Address
-Website
http://https://www.bsnl.co.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
(d) Providing Earthing with G.I. earth plate of 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
3
-
-
(e) Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and refilling etc. as required.
9
-
-
(f) Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
10
-
-
SH-II: EI Fans
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
(a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
10
-
-
(b) 2 X 6 sq. mm + 1 X 2.5 sq. mm earth wire
30
-
-
(c) 4 X 6 sq. mm + 2 X 2.5 sq. mm earth wire
10
-
-
Providing repairs to Electrical Installation / point wiring / circuit wiring / power plug wiring etc., by replacing the following accessories i/c removing of faulty items, including interconnections, etc., as required.
(a) 20 W LED fittings
12
-
-
(b) 2Way 5 A Switches
10
-
-
(c) 6A - 32 A SP MCBs
10
-
-
(d) 32A SPN Isolators (inside the panel)
27
-
-
(e) PVC angle holders
5
-
-
SH-III: Cable
Supplying of 3 ½ x 35 sq. mm PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade etc., as required.
220
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, protective covering and refilling the trench etc as required.
160
-
-
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
40
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
20
-
-
Supplying and laying of 40mm dia GI pipe of medium class by cutting CC road including making good the same after installation of GI pipe etc., as required.
20
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
(a) 3½ X 35 sq. mm (32mm)
6
-
-
SH-IV: Energy meter panel
Cleaning the existing energy meter panel by removing the faulty / broken hylam sheets / clearing the mud / debris from the panel etc., as required
3
-
-
Providing wiring with 6 sq mm copper wire / lugs for the single phase energy meter / Bus bar / double pole isolators inside the energy meter panel by removing the old faulty wiring inlcuding replacing minor spares inside the panel etc., as required.
3
-
-
Providing repairs to the energy meter panel by replacing the faulty / missing hinges / enegy meter glass covers / panel covers / nuts & bolts / din channels / broken bus bars / hylam sheets etc., as required.
3
-
-
Providing painting to the existing energy meter panel by removing rust / dust with emry paper with engineer in charge approved colour etc., as required
3
-
-
SH-V: Pumpset
Supplying, Installing, Testing and Commissioning of following rating mono submersible type pump, suitable for operation on 3 phase, 415volts, 50Hz AC supply etc., as required
(a) 3HP, 3 phase. M/s Kirloskar JOS-335
1
-
-
Supplying and fixing of the following accessories etc.,as required.
(a) 40mm dia CPVC pipe
3
-
-
40mm dia brass NRV
1
-
-
40mm dia CPVC MABT
3
-
-
40mm dia CPVC Bend
1
-
-
40mm dia CPVC Union
1
-
-
25mm dia CPVC ball valve
1
-
-
40/25mm dia CPVC 'T'
1
-
-
40 mm dia CPVC coupling
2
-
-
Supplying and fixing of electronic starter with controls viz., time delay, dry run protection, overload relay, MCB, display of voltage and current etc, suitable for following rating motors etc, as required. (make: GELCO DCP 3.4 DAF / OCLEG / SS)
(a) 3HP, 3phase.
1
-
-
Supplying and Laying of 3C 2.5 sq mm Flat submercible Pump copper Conductor cable etc. as required.
10
-
-
SH-VI: Compound Lights
Providing repairs to compound lights by replacing the following accessories i/c removing of faulty, including interconnections etc., as required.
(a) 30W LED street light fitting (Make: CG / SS)
8
-
-
Supplying and laying of 2 core 6 sq.mm, PVC sheathed PVC insulated weather proof service wire, along with earth wire 14 SWG GI wire from fitting to timer etc., as required
200
-
-
weather proof pole box along with 6A connector and 6A SP MCB (Make: syntex or SS)
4
-
-
Supplying and fixing of 25mm dia GI bracket, of length 1.0mtrs bent at suitable angle for mounting the LED type fitting including fixing the bracket on the surface of wall, etc as required.
8
-
-
Supplying and fixing of 3 kW Timer for switch "ON" & "OFF" of the compound lighting (2 circuits) i/c interconnections, testing etc., as required.
3
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements