For getting the details of etenders, if you are looking for information about them from the cumbersome government websites but are tired of doing so, Bidassist comes up with a one stop solution. It collates every Eproc telangana tender on Bidassist. One can approach it for the bidding process, registration process, etc., are explained below.
Costs
EMD
₹ 6,614Document Cost
₹ 590Tender Fee
Refer Documents
Summary
Pumpets Repair Works At Rttc Lingampally
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_BSNL_199830_1Bid Award Id
ViewTender No
13/BEDH-II/2024-25 Dated 29-06-2024Tender Authority
Bharat Sanchar Nigam Limited ViewPurchaser Address
-Website
http://https://www.bsnl.co.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
b) Studs with nuts
4
-
-
c) 12 mm nut and bolts
8
-
-
d) 3" Flange (Make: Kirloskar)
2
-
-
e) 3" CPVC Pipe (SDR 11)
6
-
-
f) 3" CPVC MABT (Brass)
1
-
-
g) 3" FABT (Brass)
1
-
-
h) 3" CPVC Union
1
-
-
i) 3" CPVC Coupling
2
-
-
Re-fixing of repaired 5HP Mono Submersible pump by lifting down into sump with the help of labour, making interconnections etc., as required.
1
-
-
Supplying and fixing of 40 A TPN MCB in existing starter box suitable for 5HP Mono submersible pump set including inter connections etc, as required
3
-
-
Supplying and fixing of Single phase preventer including inter connections (minilec) etc., as required.
3
-
-
Removing/lifting of the existing submersible type pump set along with 40mm dia HDPE pipe, 3core 6sqmm flat flexible submersible copper cable from the bore well by providing labour, hiring necessary lifting machinery i/c etc., as reqd.
1800
-
-
Repairing of 7.5 HP submersible pump set by replacing of the following spares testing etc,. As reqd.
(a) Impellers
60
-
-
(b)Bearing bushes
2
-
-
(c)Coupling sleeve
6
-
-
(d)Thrust bearing complete
1
-
-
(e)Lathe machine work of shaft for motor
1
-
-
General servicing of 7.5 hp capacity submersible pump set including the repairs and minors parts nuts and bolts painting etc,. As reqd.
1
-
-
Re-installation of the existing submersible type pump set into the bore well, by providing labour, hiring necessary lifting machinery by lowering the pump set alongwith 40mm dia HDPE pipe, 3core 6sqmm flat flexible submersible wire etc., as reqd.
1800
-
-
Supplying and fixing of MK1 DOL starter with relay range of suitable for 7.5 HP submersible pump set including inter connections and removing of old faulty starter etc,as required.
1
-
-
Transportation of submersible pump set from Site to workshop and back to TE building etc., as required.
3
-
-
Repairing of 2HP submersible pump set by replacing of the following spares, including testing etc,. as reqd. (a)Impellers
15
-
-
(b)Stage casing
15
-
-
(c)LS Impellers
1
-
-
(d)LS Stage assembly
1
-
-
(e)Stage Bush
20
-
-
(f)Stage Bearing Rings
20
-
-
(g)Valve body 32 mm
1
-
-
(h)Suction casing
1
-
-
Providing motor rewinding with copper wire (should be matched with the original winding in all respects) for 2hp submersible pumpset including testing etc., as required.
1
-
-
Attending Emergency breakdown of 2HP / 3HP / 5HP / 7.5HP Open Well/ submersible / Monoblock pumpset by identifying the fault, as per the Engineer in charge direction and replacing the damaged / burnt cable by cutting, providing new lugs (if reqd), reconnecting cable, isolating / rectifying the fault, restoration of etc., as reqd.
6
-
-
Repairing of existing 7.5HP Mono Block pump sets by replacing the following faulty components including testing etc., as reqd.
(a)Rewinding of existing 7.5HP Mono block with buy back of burnt copper winding
2
-
-
(b)Bearings
2
-
-
(c)Rubber seal/Glands
2
-
-
(d)Brass Bushes
2
-
-
(e)Lathe Machine work
2
-
-
Rewinding of existing 3HP Mono block with buy back arrangement
3
-
-
(b)Bearings
3
-
-
(c)Rubber seal/Glands
3
-
-
(d)Brass Bushes
3
-
-
(e)Lathe Machine works
3
-
-
Supplying and fixing of following electrical accessories in the existing DB/LT Panels/Meter box's Suitable for 415/230 V, 50 HZ AC supply I/c removing of faulty/burnt spares and making for new spares interconnections etc., complete as required.
(a) a) 6 to 32 Amps SP MCBs C-curve
2
-
-
b) 63 Amps Four pole Isolator
2
-
-
c) 63 Amps TP MCB
1
-
-
d) 63A kit kat rewirable fuse cut outs
3
-
-
Providing and fixing of 8 SWG dia GI wire on surface or recess for loop earthing along with existing surface / recessed conduit /submain wiring / cable etc., as required
25
-
-
Supplying and fixing of DOL starter in sheet steel enclosure including testing and commissioning etc., as required. (Make: M/s L&T MK2 (9-14A) or SS make)
3
-
-
Removing and refixing of existing 3/5 HP monoblock type pump set including disconnecting and reconnecting GI / CPVC suction / discharge lines, transportation to work shop and back to site after repairs, minor civil work, studs & bolts (if reqd), testing etc., as required.
5
-
-
Rewinding & repairing of the existing monoblock type pump set of following capacity with enamel coated / insulated copper wire, varnishing, heat treatment, replacement of bearings, packing rope, bush and water seal (for arresting water leakages), shaft lathe work etc., as per site requirements as required. Note: Cost of old burnt copper winding rate to be reduced while quoting rate
(a) 3 hp Monoblock
3
-
-
Repairing of the existing 3/5 HP monoblock type pump set by replacing pump casing with new casing including replacement of bearings, bush, shaft lathe work, testing etc., as required.
3
-
-