Bharat Electronics Limited Tender
For getting the details of etenders, if you are looking for information about them from the cumbersome government websites but are tired of doing so, Bidassist comes up with a one stop solution. It collates every Eproc telangana tender on Bidassist. One can approach it for the bidding process, registration process, etc., are explained below.
Bharat Electronics Limited - BEL Tender
Civil And Construction
Building Construction
Eprocure
Opening Date11 May 2024
Closing Date24 May 2024
Tender Amount₹ 9,42,660
Costs
EMD
₹ 9,430Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_BEL_94907_1Tender No
BEL_HYD/ES/2024/001Tender Authority
Bharat Electronics Limited ViewPurchaser Address
-Website
http://http://www.bel-india.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Dismantling/ removal aluminium/ Gypsum partitions/ Modular partition, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge.
42
-
-
Removal & disposal of PVC flooring including cleaning of chemical floor neatly and dispose within 50meters lead etc complete as per the direction of Engineer In Charge
52
-
-
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
0.5
-
-
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, nloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
3
-
-
Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. Complete
117
-
-
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
1.5
-
-
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
0.5
-
-
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more
80
-
-
Providing and fixing up to floor five level precast cement concrete string or lacing courses, copings, bed plates, anchor blocks, plain window sills, shelves, louvers, steps, stair cases, etc., of 25mm thick with 6mm dia bars 100 c/c including hoisting and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), cost of required Centering etc complete: 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 12 mm nominal size)
7
-
-
Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform
10
-
-
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)
1
-
-
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:3 (1 cement :3 coarse sand)
10
-
-
Providing and fixing specified wood frame work consisting of battens 50x25mm fixed with rawl plug and drilling necessary holes for rawl plug etc. including priming coat complete. Kiln seasoned and chemically treated hollock wood
0.05
-
-
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and 1mm thick decorative lamination on one face and balancing lamination on other face of shutters. 18 mm thick (for cupboard) including approved modular hinges with necessary Stainless steel screws (including wooden supports where ever required)
6
-
-
Providing and fixing magnetic catcher of approved quality in cupboard / ward robe shutters, including fixing with necessary screws etc. complete: Triple strip vertical type
12
-
-
Providing & fiing of 100mm SS handles as per the direction of Engineer In Charge
12
-
-
Providing and fixing 12.5mm thick skin tapered edged plain Gypsum plaster board to one side of existing aluminium partition by 25 mm long dry wall screws on studs, at equal spacing on existing aliminium frames. The boards are to be fixed to the frame work with joints staggered to avoid through cracks, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x 0.5 mm) if any, joint finisher and two coats of primer suitable for board as per manufacture's specification and direction of engineer in charge all complete.
90
-
-
Providing and fixing partition upto ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with zinc coating of 120 gms/sqm(both side inclusive), consisting of floor and ceiling channel 50mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wall with suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre.The boards are to be fixed to the frame work with joints staggered to avoid through cracks, M.S. fixing channel of 99 mm width (0.9 mm thick having two flanges of 9.5 mm each) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x 0.5 mm), joint finisher and two coats of primer suitable for board as per manufacture's specification and direction of engineer in charge all complete. 75mm overall thickness partition with 12.5 mm thick double skin tapered edged plain Gypsum plaster board conforming to IS: 2095: (part I): 2011 (Board with BIS certification marks)
10
-
-
12 mm cement plaster of mix :1:4 (1 cement: 4 coarse sand)
20
-
-
15 mm cement plaster on rough side of single or half brick wall of mix:1:4 (1 cement: 4 coarse sand)
20
-
-
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
220
-
-
Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer’s specification. Two or more coats on new work
210
-
-
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement primer
240
-
-
Wall painting with acrylic emulsion paint (Asian Royale or equivalent) of approved brand and manufacture to give an even shade : Two or more coats on new work
35
-
-
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work
5
-
-
Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture (Cost includes removing & refixing of false ceiling tiles)
45
-
-
Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
70
-
-
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
50
-
-
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, washbasin counters, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite stone slab of all colour and texture
4
-
-
Providing and fixing Ist quality ceramic glazed wall tiles of size 600x300mm conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
6
-
-
Providing and fixing 2mm thick homogeneous Polyvinyl chloride sheet in flooring and skirting in approved pattern on a smooth and damp proof base using rubber based adhesives of approved quality recommended by manufacturer including rolling with light wooden roller weighing about 5 kg all complete as directed by Engineer – in – Charge, in approved colour and shade. 2 mm thick sheet (LG, wonderfloor, responsive or any equivalent make). The existing flooring shall be cleaned thoroughly as directed to make it free from dust and any undulations in the existing floor shall be made good suitably before laying the vinyl flooring. All joints of the PVC flooring shall be welded using conductive PVC electrode so as to get a uniform, seamless surface. The finished vinyl flooring shall be free from air bubbles and undulations and shall be thoroughly cleaned and polished. (Note: Sample materials shall be furnished and got approved by the company before commencement of laying work. Payment will be made for the actual area of flooring/ skirting laid and accepted by the company including PVC weld joints).
97
-
-
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 20 mm nominal outer dia Pipes
10
-
-
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal outer dia Pipes
5
-
-
Providing & fixing PVC floor trap of 100mm dia including Cement Mortar 1:4 and placing of SS jali as per the directions of Engineer in Charge
1
-
-
Providing and fixing pipes of 75 mm dia, unplasticised-Rigid PVC pipes including bend, coupler, clamps etc including jointing with seal ring conforming to IS etc., complete.
10
-
-
Providing and fixing square-mouth S.W. gully trap class SP-1
complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 100x100 mm size P type With common burnt clay F.P.S. (non modular)
bricks of class designation 7.5
1
-
-
Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : For pipes 75 to 250 mm diameter
1
-
-
Providing and fixing white vitreous wash basin (Model Zen, catalogue. No. 10049 of hindware make or equivalent) of size 560x450 mm with single 15 mm pillar tap (Jaquar make PRS-031), waste coupling (cat.- 709), angular stop cock CON-053KN and bottle trap of model no. ALD-769L-300x190mm with wall flange of `Jaquar' make with necessary coupling. cutting and making good the walls wherever required etc., complete
1
-
-
Supplying of Automatic Hand Dryer Indoor Wall - Mounted for dry the hands after hand washing automatically in Bathrooms Mounting type :- Wall mounting, Machine Type :- Automatic, Voltage:- 220V - 230V, Frequency:- 50HZ - 60HZ, Power:- 1800W Ref model :- Dolphy-DAHD0011 with equivalent in approved makes
1
-
-
Providing and fixing liquid soap container of Jaguar make cat no SDR-WHT-DJ0010F with glass bottle with matching colout CP screws etc complete.
1
-
-
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
1
-
-
Providing and fixing Towel rod of length 450mm long of Jaguar make cat no. ACN-1111BNM with matching CP screws etc complete
1
-
-
Providing & fixing roller blinds of approved make, colour and shade with head rail and bottom rail. The cord locks shall have a stainless steel / brass acrylic main roller with a locking mechanism which will get locked automatically on release of the chord.
20
-
-
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron)
20
-
-
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron)
66
-
-
Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. Complete: 125x63x4 mm Note :- Aluminum hinges shall not be used in wooden shutters, stainless steel hinges shall be preferred.
15
-
-
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5.50 mm thickness (weight not less than 12.50 kg/sqm)
10
-
-
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineerin- charge. Pre-laminated particle board with decorative laminationn on both sides.
2
-
-
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete.
5
-
-
Providing and fixing aluminium handles of size 125mm ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. Complete 125 mm
10
-
-
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Single rubber stopper
5
-
-
Providing and fixing 100mm brass locks (best make of approved quality) for aluminium doors including necessary cutting and making good etc. Complete
4
-
-
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete
3
-
-
Providing and fixing Birla 3M sticker etching of approved color shade to form logo, design patterns etc on the existing glazed windows as directed by Engineer In Charge. Rate quoted shall be for the complete finished work including all the materials and labour. Actual area of etching provided will be measured for payment.
5
-
-
Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof.
4
-
-
Providing & fixing bevelled edge 8mm thick 2 acrylic sheets (for sandwich board) with required holes and studs including stickering as per the direction of Engineer in Charge
2
-
-
Providing & fixing of wallpaper including of any brand including applying of suitable adhesive (as per Manufacturers specification) evenly spread coating of paste on the wall, remove air pockets by using required tools and joint wall paper to matching the pattern at the edges as directed by the Engineer In Charge.
45
-
-
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge.With cement mortar 1:4 (1cement: 4 coarse sand)
10
-
-
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes
750
-
-
Providing and fixing not less than 0.50mm thick 1000mm wide Hi-Rib-100 Galvalume high tensile cold rolled steel roofing sheets/north light curves/ridges/cladding/ flashing of taurus blue or any other approved colour and in required lengths having a yield strength of 550 M Pa as per AS 1397 having Galvalume coating class AZ 150 (minimum 150 gm. per Sq. metre total zinc- Aluminium alloy coating on both sides). The sheets shall be fixed to the purlins with suitable over laps in longitudinal and lateral directions and by providing Self fit fasteners along with EPDM washers and Polysulphide sealant as per manufacturers specifications.The adjacent sheets shall be connected longitudinally by using appropriate size GI seam fasteners at a maximum spacing of 375 mm with necessary GI washers, EPDM washers and nuts all as specified and or directed etc., complete. (Note- actual area of sheets including ridges as laid will be measured for payment.
28
-
-
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Gutter (600 mm over all girth)
14
-
-
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes: 75 mm diameter
10
-
-
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion Bend 87.5°: 75 mm dia
4
-
-
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion:Shoe (Plain) 75 mm dia
4
-
-
PART-B NETWORK AND COMMUNICATION WORKS
-
-
-
Supplying, Installation, Termination, Labling & Testing of dual (2) port flush type face plate.CAT6. Make: AMP/Systimax-Comscope/Panduit-Pannet
10
-
-
Supplying, Installation, Termination, Labling & Testing of RJ-45 modular jacks, complaint with ISOllEC11801 NSI/TIA/EIA-568,should Accept solid 22-24 AWG diameter conductors with certified for UL94V-0 rated,series connecting hardware standards .CAT6 (green or blue). Make: AMP/Systimax-Comscope/Panduit-Pannet
20
-
-
Supplying, Installation, Termination, Testing, Commissioning and Labling of 24-port Patch Panel, UTP Category 6,TIA / EIA 568-6.2, with min1000 mating cycles, Metal rear cable manager to properly guide cables to point of termination and come with Velcro straps for tying the cables,Modular connector should be FCC part68, Subpart F and IEC-60603-7 allows for 568 A/B wiring configuration and IDC body & cover material Fire - Retardant Make: AMP/Systimax-Comscope/Panduit-Pannet
1
-
-
Supplying, Laying, Labling & Testing of UTP Category 6 patch cords 2 mtrs, TIA / EIA 568-8.2 ,with LSOH - Low Smoke Zero Halogen Free. and 1000 mating cycles, RJ 45 plug should be of Polycarbonate FCC part 68 subpart F, UL 94V-0 Make: AMP/Systimax-Comscope/Panduit-Pannet
5
-
-
Supplying, Laying, Labling & Testing of UTP Category 6 patch cords 1 mtrs, TIA / EIA 568-8.2 ,with LSOH - Low Smoke Zero Halogen Free. and 1000 mating cycles, RJ 45 plug should be of Polycarbonate FCC part 68 subpart F, UL 94V-0 Make: AMP/Systimax-Comscope/Panduit-Pannet
5
-
-
Supplying and laying of 1" PVC Pipes with gutta/ clamps etc as directed by engineer incharge.Make: Universal/Supreme/Classic
100
-
-
Supplying, Installation, cabling, and labeling of 12U type Network Rack – MAKE : APW President / NETRACK / RITTAL
1
-
-
Supply of Cat 6 Cable
305
-
-
PART-C ELECTRICAL WORKS
-
-
-
Supplying of follwing size LT power cable with Copper conductor, XLPE/PVC insulation, PVC inner sheathed, unarmoured, 1.1KV grade (2XY) cable, confirming IS:7098(part-1) with relevant standards and laying of the same in existing trenches/duct/pipe/ on the wall/ cable trays with suitable clamps as directed by EIC. 4C X 10 Sq mm Make: Kel, RR kable, CCI, Nicco, Universal, Havells, Gloster , Finolex , Traco ,Bonton ,Apar , RPG.
40
-
-
Supplying and wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in in the existing surface/ recessed steel/ PVC conduit as required steel conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire , Make : Kel, RR kable, CCI, Nicco, Universal, Havells, Gloster, Finolex, Traco, Bonton, Apar, RPG.
200
-
-
Supplying and fixing of 25 mm size of medium class PVC conduit along with accessories on the wall/ column/ ceiling/ truss as surface/recess system including cutting the wall and making good the same in case of recessed conduit with associated civil works as required. Make: Astral / Ashirvad / Sudhakar / Prince / Supreme.
300
-
-
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 2 x 1.5 sq.mm Make: Vip, Nelco, Precision , Universal.
230
-
-
Supplying and drawing/wiring of 3 x 4 sq.mm size of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. Make: Kel, RR kable, CCI, Nicco, Universal, Havells, Gloster , Finolex , Traco ,Bonton ,Apar , RPG.
200
-
-
Supplying and fixing 32 A rating, 240/415 V, 10 kA, "C" curve, Double pole, miniature circuit breaker suitable for inductive load with enclosure to fix the same on to wall complete with connections, testing and commissioning etc. as required. Make: Legrand, Siemens, L&T, Hanger, Schnieder, ABB.
2
-
-
Supplying and fixing of 12 module (200mm x 150mm) GI box alongwith modular base & cover plate for modular switches in recess including associated civil works etc., as required. Make: Crab Tree(Athena), MK India (Blenz), Legrand (Myris), Wipro (Northwest), Kolors (Krest), ABB (Cheiron), Schneider, Anchor, Lisha,Cona.
2
-
-
Supplying and fixing of 8 module (125mm x 125mm) GI box alongwith modular base & cover plate for modular switches in recess including associated civil works etc., as required. Make: Crab Tree(Athena), MK India (Blenz), Legrand (Myris), Wipro (Northwest), Kolors (Krest), ABB (Cheiron), Schneider, Anchor, Lisha,Cona.
2
-
-
Supplying and fixing of modular 6pin 15A/16A socket outlet on the existing modular plate & switch box including making electrical connections but excluding modular plate etc. as required. Make: Crab Tree(Athena), MK India (Blenz), Legrand (Myris), Wipro (Northwest), Kolors (Krest), ABB (Cheiron), Schneider, Anchor, Lisha,Cona.
6
-
-
Supplying and fixing of modular 15A/16A SP switch on the existing modular plate & switch box including making electrical connections but excluding modular plate etc. as required. Make: Crab Tree(Athena), MK India (Blenz), Legrand (Myris), Wipro (Northwest), Kolors (Krest), ABB (Cheiron), Schneider, Anchor, Lisha,Cona.
6
-
-
Supplying and fixing of modular 3pin 5A/6A socket outlet on the existing modular plate & switch box including making electrical connections but excluding modular plate etc. as required. Make: Crab Tree(Athena), MK India (Blenz), Legrand (Myris), Wipro (Northwest), Kolors (Krest), ABB (Cheiron), Schneider, Anchor, Lisha,Cona.
4
-
-
Supplying and fixing of modular 5A/6A switch on the existing modular plate & switch box including making electrical connections but excluding modular plate etc. as required. Make: Crab Tree(Athena), MK India (Blenz), Legrand (Myris), Wipro (Northwest), Kolors (Krest), ABB (Cheiron), Schneider, Anchor, Lisha,Cona.
23
-
-
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required..
6
-
-
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.00, Air delivery minimum 210 Cum/Min, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. Make: Orient/ Crompton/ Usha/ Bajaj / Almonard.
5
-
-
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. Make: Legrand, Siemens, L&T, Hanger, Schnieder, ABB.
2
-
-
Supply, installation, Testing and Commissioning of 36W LED 2'X2' recess type Led mounted square luminaire by fixing of the same in the false ceiling by providing required down rod/ chain, clamps screws/ anchor bolt-nuts, washers etc., making electrical connections, earthing etc., as required/ directed by engineer-in-charge.The luminaire should be equiped with nominal system lumen output of 3600lm and a minimum system efficacy of 100lm/W. The LED chip is mounted in Metal core printed circuit board with thermal paste for better heat dissipation.The luminaire shall have a rated system life of 50,000BH @ L70. The luminare should have beam angle of 110 Deg with a color temperature of 5700K and CRI80. The luminaire shall meet IP20 rating HPF with THD10% and The luminaire housing should made of CRCA powder coated finish, high efficienct anti glare high transmittance PMMA diffuser for better light distribution and other standard accessories. complete in all aspects and as directed by Electrical-In-Charge. The luminaire has the features of Input Voltage : AC220-240V, 50/60Hz, Voltage operating range : 100-300V with High Surge Protection : 2.5KV, and confirms to IEC safety standard (IEC60598, IEC61347) having the dimensions of 595 × 595 x 75mm (L X W X H). The total power consumption should not exceed 36W (including driver).The luminaire shall have operating temperature of (-10) Deg C to 45 Deg C.The luminaire have separate energy efficent electronic DALI driver. (Model- PHILIPS RC 380B LED42S-5700 G6 L60W60 PSU OD or Equivalent model in Wipro, Havalls, Bajaj, Crompton. )
9
-
-
Supply,Installation,testing & commisioning of 20W LED luminaire. Suspended / surface Mounted with length of 1150 mm available.. Best in class LEDs, load 20W,energy saving, environmental friendly, long life, corrosion resistant, impact proof, surface mounting IP66 luminaire with PC housing & opal finish cover suitable for wet location. (Model- HAVELLS - MAGNUMGRANDGOLD20WLED857SPC or Equivalent model in Wipro, Philips, Bajaj, Crompton. )
3
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements