Armoured Vehicles Nigam Limited Tender
For getting the details of etenders, if you are looking for information about them from the cumbersome government websites but are tired of doing so, Bidassist comes up with a one stop solution. It collates every Eproc telangana tender on Bidassist. One can approach it for the bidding process, registration process, etc., are explained below.
Armoured Vehicles Nigam Limited - AVNL Tender
Electrical and Electronics
Eprocure
Opening Date1 Oct 2024
Closing Date22 Oct 2024
Tender Amount₹ 2,25,23,306
Costs
EMD
₹ 3,00,300Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_AVNL_209916_1Bid Award Id
ViewTender No
76026/TE-09/OFMK/EOC/HFMD LT PANEL/24-25Tender Authority
Armoured Vehicles Nigam Limited ViewPurchaser Address
-Website
http://etenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Indoor power distribution panel: Supply, Installation & Commissioning of LT power distribution Panel shall have provision of the following (without ACBs and MCCBs) i) Air circuit breaker 1000 amps, 4 pole,50 KA,manual draw out type as Incomer and the following as outgoing ACB’s & MCCBs
ii) ACB, 4 pole, 630A, 50KA-2 Nos.
iii) MCCB, 3 pole, 400A, 36KA-2 Nos.
iv) MCCB, 3 pole, 160A, 36KA-3 Nos
Panel shall be designed as per Sl. No.1 of specification and scope of work.
2
-
-
... More
Indoor power distribution panel: Supply, Installation & Commissioning of LT power distribution Panel shall have provision of the following (without ACBs and MCCBs) i) Air circuit breaker 1000 amps, 4 pole,50 KA,manual draw out type as Incomer and the following as outgoing MCCBs
ii) MCCB, 3 pole, 400A, 36KA-2 Nos.
iii) MCCB, 3 pole, 250A, 36KA-3 Nos. iv.) MCCB, 3 pole, 160A, 36KA-3 Nos.
v) MCCB, 3 pole, 125A, 16KA-7 Nos.
Panel shall be designed as per Sl. No.1 of specification and scope of work.
7
-
-
... More
Indoor power panel : Supply, Installation & Commissioning of LT power distribution Panel shall have provision of the following (without ACBs )
i) Air circuit breaker 800 amps, 4 pole,50 KA,manual draw out type as Incomer.
Panel shall be designed as per Sl. No.1 of specification and scope of work.
2
-
-
... More
Indoor power panel: Supply, Installation & Commissioning of LT power distribution Panel shall have provision of the following (without MCCBs)
i) MCCB, 3 pole,400A, 36 KA as incomer. Panel shall be designed as per Sl. No.1 of specification.
1
-
-
... More
Indoor power distribution panel : Supply, Installation & Commissioning of LT power distribution Panel shall have provision of the following (withoutMCCBs)
i)MCCB, 3 pole , 400A ,36 KA as incomer and the following as outgoing MCCBs ii) MCCB, 3 pole,250A,36KA-01 No. Iii) MCCB, 3 pole, 160A, 36KA-02 Nos.
Iv) MCCB, 3 pole, 125A, 16KA-02 Nos.
Panel shall be designed as per Sl. No.1 of specification.
3
-
-
... More
Indoor power distribution panel: Supply, Installation & Commissioning of LT power distribution Panel shall have provision of the following(without MCCBs)
i)MCCB, 3 pole , 400A ,36 KA as incomer and the following as outgoing MCCBs
ii) MCCB, 3 pole, 160A, 36KA-04 Nos.
iii) MCCB, 3 pole, 125A, 16KA-06 Nos. Panel shall be designed as per Sl. No.1 of specification.
10
-
-
... More
Indoor power distribution panel: Supply, Installation & Commissioning of LT power distribution Panel shall have provision of the following (without ACBs and MCCBs)
i) Air circuit breaker 1000 amps, 4 pole,50 KA,manual draw out type as Incomer and the following as outgoing MCCBs
ii) MCCB, 3 pole, 400A, 36KA-1 No.
iii) MCCB, 3 pole, 250A, 36KA-2 Nos. iv.) MCCB, 3 pole, 125A, 16KA-7 Nos.
Panel shall be designed as per Sl. No.1 of specification and scope of work
2
-
-
... More
Indoor power distribution panel: Supply, Installation & Commissioning of LT power distribution Panel shall have provision of the following (without ACBs and MCCBs) i) Air circuit breaker 1000 amps, 4 pole,50 KA,manual draw out type as Incomer and the following as outgoing MCCBs
ii) MCCB, 3 pole, 400A, 36KA-2 Nos.
iii) MCCB, 3 pole, 250A, 36KA-2 Nos. iv.) MCCB, 3 pole, 160A, 36KA-3 Nos.
v) MCCB, 3 pole, 125A, 16KA-3 Nos.
Panel shall be designed as per Sl. No.1 of specification and scope of work
4
-
-
... More
Indoor power distribution panel: Supply, Installation & Commissioning of LT power distribution Panel shall have provision of the following (without ACBs and MCCBs) i) Air circuit breaker 800 amps, 4 pole,50 KA,manual draw out type as Incomer and the following as outgoing MCCBs
ii) MCCB, 3 pole, 400A, 36KA-1 No.
iii) MCCB, 3 pole, 250A, 36KA-2 Nos.
iv) MCCB, 3 pole, 160A, 36KA-3 Nos.
v) MCCB, 3 pole, 125A, 16KA-4 Nos.
Panel shall be designed as per Sl. No.1 of specification and scope of work
5
-
-
... More
Indoor power distribution panel: Supply, Installation & Commissioning of LT power distribution Panel shall have provision of the following (without ACBs and MCCBs) i) Air circuit breaker 1000 amps, 4 pole, 50 KA, manual draw out type as Incomer and the following as outgoing ACB’s & MCCBs
ii) ACB, 4 pole, 630A, 50KA-1 No.
iii) MCCB, 3 pole, 400A, 36KA-2 Nos.
iv) MCCB, 3 pole, 250A, 36KA-2 Nos.
v) MCCB, 3 pole, 160A, 36KA-3 Nos.
vi) MCCB, 3 pole, 125A, 16KA-3 Nos.
Panel shall be designed as per Sl. No.1 of specification and scope of work.
5
-
-
... More
Dismantling of Panels: Dismantling of existing Electrical panels including disconnection of cables, glands etc completely and shifting to stores as instructed
by EIC.
50
-
-
... More
Air circuit Breaker (ACB): Supply and Fixing of ACB 4 Pole, 415 V, Manual Draw
out type with microprocessor release of capacity 1000 Amps, 50KA breaking capacity with Earth fault, Over load, short circuit protection, shunt trip, Ics=Icu=Icw (1 sec) and auxiliary contacts, LCD Back light Display, Front ON/OFF indication, spring charge/Discharge indication, 3 distinct mechanical positions indication, Make GE
/Areva T&D/Schneider/ Siemens/ L&T/ABB The incoming/ outgoing ACBs are to be installed and commissioned in the LT Distribution Panel as mentioned Sl. No.1 of specification and scope of work
20
-
-
... More
Air circuit Breaker (ACB): Supply and Fixing of ACB 4 Pole, 415 V, Manual Draw out type with microprocessor release of capacity 800 Amps, 50KA breaking capacity with Earth fault, Over load, short circuit protection, shunt trip, Ics=Icu=Icw (1 sec) and auxiliary contacts, LCD Back light Display, Front ON/OFF indication, spring charge/Discharge indication, 3 distinct mechanical positions indication, Make GE/Areva T&D/Schneider/Siemens/L&T/ABB The incoming/outgoing ACBs are to be installed and commissioned in the LT Distribution Panel as mentioned Sl. No.1 of specification and scope of work
12
-
-
... More
Air circuit Breaker (ACB): Supply and Fixing of ACB 4 Pole, 415 V, Manual Draw out type with microprocessor release of capacity 630 Amps, 50KA breaking capacity with Earth fault, Over load, short circuit protection, shunt trip, Ics=Icu=Icw (1 sec) and auxiliary contacts, LCD Back light Display, Front ON/OFF indication, spring charge/Discharge indication, 3 distinct mechanical positions indication, Make GE/Areva T&D/Schneider/ Siemens/ L&T/ABB The incoming/ outgoing ACBs are to be installed and commissioned in the LT Distribution Panel as mentioned Sl. No.1 of specification and scope of work
9
-
-
... More
Moulded Case circuit Breaker (MCCB): Supply and Fixing of MCCB 3 Pole, 415 V, Adjustable type, 400 Amps with breaking capacity 36 KA. The Incoming & outgoing Moulded Case Circuit Breakers are to be installed and commissioned in the LT Distribution Panel as mentioned above, Confirms IEC 60947, IS 13947.
Make: GE/Schneider /Siemens/ L&T/ ABB.
61
-
-
... More
Moulded Case circuit Breaker (MCCB): Supply and Fixing of MCCB 3 Pole, 415 V, Adjustable type, 250 Amps with breaking capacity 36 KA. The incoming & outgoing Moulded Case Circuit Breakers are to be installed and commissioned in the LT Distribution Panel as mentioned above, Confirms IEC 60947, IS 13947.
Make:- GE/Schneider /Siemens/ L&T/ ABB.
66
-
-
... More
Moulded Case circuit Breaker (MCCB): Supply and Fixing of MCCB 3 Pole, 415 V, Fixed type, 160 Amps with breaking capacity
36 KA. The Incoming & outgoing Moulded Case Circuit Breakers are to be installed and commissioned in the LT Distribution Panel as mentioned above, Confirms IEC 60947, IS 13947.
Make:- GE/Schneider /Siemens/ L&T/ ABB.
135
-
-
... More
Moulded Case circuit Breaker (MCCB): Supply and Fixing of MCCB 3 Pole, 415 V, Fixed type, 125 Amps with breaking capacity 16 KA. The Incoming & outgoing Moulded Case Circuit Breakers are to be installed and commissioned in the LT Distribution Panel as mentioned above, Confirms IEC 60947, IS 13947. Make:- GE/Schneider /Siemens/ L&T/ ABB.
236
-
-
... More
Earthing: Earthing complete with Galvanised steel earth plate electrode 60x60 cm X 6 mm thick, buries directly in ground (Earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised iron or steel strip 25x4 mm as earthing lead by means of bolts, nuts, check nuts and watchers of GI or steel all as shown in Electrical plate no 3 connected to earth test point as specified or indicated including testing on completion.
15
-
-
... More
Earth continuity conductor: M&L Earth continuity conductor for or main earthing lead fixed to wall on batten or recess chase or buried in ground or drawn in conduit/pipe or fixed to pole or any other indicated situation for loop earthing etc, as required 25x4 mm GI strip
600
-
-
... More
GI PIPE: Supply and fixing of GI pipe to protect earthing strip 40 mm dia. medium grade complete all as specified and directed
15
-
-
... More
GI PIPE: Supply and fixing of GI pipe to protect earthing strip 20 mm dia. medium grade complete all as specified and directed
15
-
-
... More
Excavation: Excavating in trenches in hard/dense soil not exceeding 1.5 metre wide and not exceeding 1.5 metre depth over areas in Hard/Dense soil getting out complete all as specified and directed.
38
-
-
... More
cement concrete: providing cement concrete cast in situ for each pit chamber slightly rounded or chamfer angles including finishing by using type B1 1:2:4 (20mm graded aggregate complete all as specified by the EIC
3
-
-
... More
precast cement concrete: B1 1:2:4 (20mm graded aggregate) in covers slabs for earth pits with faces complete all as specified and diriected
1
-
-
... More
mild steel bar 8 mm dia. over cut to length, bend to shape for hooking quality conforming to GD 1, IS 432(pt.1) complete all as specified by the EIC
100
-
-
... More
Synthetic painting to plastered surfaces: Surfaces of any description over 10 cm girth or width. Synthetic enamel single coat.
15
-
-
... More
Writing letters or figures (Block, Roman, italic or Indian) n exc 30cm high
100
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements