Armoured Vehicles Nigam Limited Tender
For getting the details of etenders, if you are looking for information about them from the cumbersome government websites but are tired of doing so, Bidassist comes up with a one stop solution. It collates every Eproc telangana tender on Bidassist. One can approach it for the bidding process, registration process, etc., are explained below.
Armoured Vehicles Nigam Limited - AVNL Tender
Electrical and Electronics
Eprocure
Opening Date8 Jun 2024
Closing Date15 Jul 2024
Tender Amount₹ 1,04,39,894
Costs
EMD
₹ 1,80,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_AVNL_197752_1Bid Award Id
ViewTender No
76026/TE-32/OFMK/EOC/VA FA LT PANEL/2023-24Tender Authority
Armoured Vehicles Nigam Limited ViewPurchaser Address
-Website
http://etenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
iii) Copper earth bar of size 50x 5mm to be fixed in the panel for earthing
-
-
-
iv) All LT panels shall consists of Digital Volt meter and Ammeter and Multifunction meters with selector switches .Inter connection of the CTs, relays and meters with suitable size of copper wire and perules.
-
-
-
v) Separate and adequate compartments shall be provided for accommodating instruments, indication lamps, fuses etc.
-
-
-
vi) All outgoing circuits should have digital Ammeters of suitable range of class 1 accuracy with suitable CTs.
-
-
-
vii) All the MCCBs should have Extended rotary handles ,phase separators, spreaders, locking device, removable base plate, Neutral links, extended terminals, adjustable thermo magnetic setting, Ics=Icu=Icw (1 sec) ,Overload protection, Short Circuit protection. Indication lamps ON, OFF, TRIP, RYB phase indication lamps LED type.
-
-
-
viii) All 400 Amps out going feeders shall consists of seperate Multifunction meters along with suitable CTs.
-
-
-
(NOTE: THE PANEL DESIGN SHALL BE AS PER POINT NUMBER 1 to 1.08) Indoor Distribution panel : Supply, Erection & Commissioning of of LT indoor Distribution panel shall have a provision of the following (without ACBs and MCCBs) i) Air circuit breaker 800 amps, 4 pole,Ics=Icu=Icw (1 sec) ,50 KA as Incommer. and the following as outgoing MCCBs
ii) MCCB, 3 pole, 400A, 35KA,-4Nos
iii) MCCB, 3 pole, 250 A, 35KA -2Nos
iv) MCCB, 3 pole,125A,16KA-2 Nos
v)MCCB, 3 pole,25-100A, 16KA-4 Nos and the Panel shall be designed as per Sl. No.1 of specification
7
-
-
(NOTE: THE PANEL DESIGN SHALL BE AS PER POINT NUMBER 1 to 1.08) Indoor Distribution panel : Supply, Erection & Commissioning of of LT indoor Distribution panel shall have a provision of the following (without MCCBs) i)MCCB, 3 pole , 400A ,35 KA as incommer and the following as outgoing MCCBs
ii) MCCB, 3 pole, 250 A, 35KA -2Nos
iii) MCCB, 3 pole,125A,16KA-2 Nos
iv)MCCB, 3 pole,25-100A, 16KA-4 Nos and the Panel shall be designed as per Sl. No.1 of specification
5
-
-
(NOTE: THE PANEL DESIGN SHALL BE AS PER POINT NUMBER 1 to 1.08) Indoor Distribution panel : Supply, Erection & Commissioning of of LT indoor Distribution panel shall have a provision of the following (without MCCBs) i)MCCB, 3 pole , 400A ,35 KA as incommer and the following as outgoing MCCBs
ii) MCCB, 3 pole, 250 A, 35KA- 1 Nos
iii) MCCB, 3 pole,125A,16KA- 1 Nos
iv)MCCB, 3 pole,25-100A, 16KA- 6 Nos and the Panel shall be designed as per Sl. No.1 of specification
5
-
-
(NOTE: THE PANEL DESIGN SHALL BE 1 to 1.08) Indoor Distribution panel : Supply, Erection & Commissioning of of LT indoor Distribution panel shall have a provision of the following (without MCCBs) i)MCCB, 3 pole , 400A ,35 KA as incommer and the following as outgoing MCCBs
ii) MCCB, 3 pole, 250 A, 35KA- 2 Nos
iii) MCCB, 3 pole,125A,16KA- 2 Nos
iv)MCCB, 3 pole,25-100A, 16KA- 8 Nos and the Panel shall be designed as per Sl. No.1 of specification
9
-
-
(NOTE: THE PANEL DESIGN SHALL BE AS PER POINT NUMBER 1 to 1.08) Indoor Distribution panel : Supply, Erection & Commissioning of of LT indoor Distribution panel shall have a provision of the following (without MCCBs) i)MCCB, 3 pole , 400A ,35 KA as incommer and the following as outgoing MCCBs
ii) MCCB, 3 pole, 250 A, 35KA- 1 Nos
iii) MCCB, 3 pole,125A,16KA- 6 Nos
iv)MCCB, 3 pole,25-100A, 16KA- 15 Nos and the Panel shall be designed as per Sl. No.1 of specification
1
-
-
(NOTE: THE PANEL DESIGN SHALL BE AS PER POINT NUMBER 1 to 1.08) Indoor Distribution panel : Supply, Erection & Commissioning of of LT indoor Distribution panel shall have a provision of the following (without MCCBs) i), Air circuit breaker 800 amps, 4 pole,Ics=Icu=Icw (1 sec) ,50 KA as Incommer. and the following as outgoing MCCBs
ii) MCCB, 3 pole, 250 A, 35KA- 5 Nos
iii) MCCB, 3 pole,125A,16KA- 14 Nos
iv)MCCB, 3 pole,25-100A, 16KA- 6 Nos and the Panel shall be designed as per Sl. No.1 of specification
1
-
-
Dismantling of Panel: Dismantling of existing Electrical panels including disconnection of cables, glands etc completely and shifting to stores as instructed by EIC.
26
-
-
Air circuit Breaker : Supply and Fixing of ACB 4 Pole, 415 V, Manual Drawout type with microprocessor release of capacity 800 Amps, 50KA breaking capacity with Earth fault ,Over load , short circuit protection, shunt trip , Ics=Icu=Icw (1 sec) and auxiliary contacts, LCD Back light Display, Front ON/OFF indication, spring charge/Discharge indication, 3 distinct mechanical positions indication, suitable power pack for shunt trip, Make GE /Areva T&D/Schneider/ Siemens/ L&T/ABB The incomming ACBs are to be installed and commissioned in the LT Distribution Panel as mentioned above
8
-
-
MCCB: Moulded Case circuit Breaker: Supply and Fixing of MCCB 3 Pole, 415 V, Adjustable type, 400 Amps with breaking capacity 36 KA,Ics=Icu=Icw (1 sec) . The Incomming & outgoing Moulded Case Circuit Breakers are to be installed and commissioned in the LT Distribution Panel as mentioned above, Confirms IEC 60947, IS 13947.
Make:- GE/Schneider /Siemens/ L&T/ ABB.
51
-
-
MCCB (Moulded Case circuit Breaker): Supply and Fixing of MCCB 3 Pole, 415 V, Adjustable type, 250 Amps with breaking capacity 36 KA,Ics=Icu=Icw (1 sec) . The incomming & outgoing Moulded Case Circuit Breakers are to be installed and commissioned in the LT Distribution Panel as mentioned above, Confirms IEC 60947, IS 13947.
Make:- GE/Schneider /Siemens/ L&T/ ABB.
53
-
-
MCCB (Moulded Case circuit Breaker): Supply and Fixing of MCCB 3 Pole, 415 V, Fixed type, 125 Amps with breaking capacity 16 KA,Ics=Icu=Icw (1 sec) . The Incomming & outgoing Moulded Case Circuit Breakers are to be installed and commissioned in the LT Distribution Panel as mentioned above, Confirms IEC 60947, IS 13947.
Make:- GE/Schneider /Siemens/ L&T/ ABB.
67
-
-
MCCB (Moulded Case circuit Breaker): Supply and Fixing of MCCB 3 Pole, 415 V, Fixed type, 25 to 100 Amps with breaking capacity 16 KA,Ics=Icu=Icw (1 sec) . The Incomming & outgoing Moulded Case Circuit Breakers are to be installed and commissioned in the LT Distribution Panel as mentioned above, Confirms IEC 60947, IS 13947.
Make:- GE/Schneider /Siemens/ L&T/ ABB.
171
-
-
Earthing:Earthing complete with Galvanised steel earth plate electrode 60x60 cm X 6.3 mm thick ,buries directly in ground (Earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not lessthan 1.5 meters below ground level,connected to galvanised iron or steel strip 25x4 mm as earthing lead by means of bolts,nuts,check nuts and washerers of GI or steel all as shown in Electrical plate no 3 connected to earth test point as specified or indicated including testing on completion.
40
-
-
Earth continuity conductor: M&L Earth continuity conductor for or main earthing lead fixed to wall on batten or recess chase or buried in ground or drawn in conduit /pipe or fixed to pole or any other indicated situation for loop earthing etc,as required 25x4 mm GI strip
1600
-
-
GI PIPE :Supply and fixing of GI pipe to protect earthing strip 40 mm dia medium grade complete all as specified and directed
40
-
-
GI PIPE :Supply and fixing of GI pipe to protect earthing strip 20 mm dia medium grade complete all as specified and directed
40
-
-
Excavation: Excavating in trenches in hard/dense soil not exceeding 1.5 metre wide and not exceeding 1.5 metre depth over areas in Hard/Dense soil getting out complete all as specified and directed( Dimensions.
100
-
-
cement concrete:providing cement concrete cast in situ for each pit chamber slightly rounded or chamfere angles including finisheing by using type B1 1:2:4 (20mm graded aggregate complete all as specified by the EIC
8
-
-
precast cement concreate: B1 1:2:4 (20mm graded aggregate) in covers slabs for earth pits with faces complete all as specified and directed
2
-
-
mild steel bar 8 mm dia over cut to length ,bend to shape for hooking quality conforming to GD 1 ,IS 432(pt .1 ) complete all as specified yb the EIC
250
-
-
Synthetic panel painting to plastered surfaces: Surfaces of any description over 10 cm girth or width. Single coat of enamel painting.
50
-
-
Writing letters or figures (Block, Roman, italic or Indian) n exc 30cm high
200
-
-