V O Chidambaranar Port Trust Tender
Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.
V O Chidambaranar Port Trust Tender
Security and Emergency Services
Eprocure
Opening Date17 May 2024
Closing Date4 Jul 2024
Tender Amount₹ 1,88,89,110
Costs
EMD
₹ 3,77,782Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_VOCPT_195824_1Bid Award Id
ViewTender No
MEE-SE-DMM-1808-2024Tender Authority
V O Chidambaranar Port Trust ViewPurchaser Address
-Website
http://https://www.vocport.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Supply of Fibre count : 12, Jacket material : HDPE, Fibre type : Single mode OS1, Type of tube / no. of tube / no. of core per tube : Unitube /1/6Fibre cable generally conforming to IEC 60793- 1, IEC 60793-2, and to conform other normative specifications as specified in IEC:60793 Part 1 and Part 2, Maximum Crush Resistance(short) 125 lbs/in (220 N/cm), Maximum Crush Resistance(long) 63 lbs/in (110 N/cm), Minimum Bend Radius(installation)20 X OD, Minimum Bend Radius(in service) 10 X OD, Max Tensile load 1500N Single Mode Optical Fiber used in manufacturing optical fiber cables shall be as per ITU-T Rec. G 652 D
1700
-
-
... More
Supply of permanently Lubricated HDPE Telecom Ducts for use as underground optical fibre cable conduits The HDPE pipes suitable for Optical Fibre Cable is pull through 40mm outer diameter PLB Pipes/Coils having strength of 10 Kg/sq. cm. Necessary HDPE socket, PR rope, PLB end caps To prevent entry of rodents into PLB pipes, the ends of PLB pipes are sealed at every manhole and joint using rodent resistant hard rubber bush (cap) after optical fibre cable is pulled. HDPE pipe as per specification RDSO/SPN/TC/45/2013 HDPE pipe: ISI approved HDPE pipe. The pipes shall be supplied with ISI mark on each pipe. (The pipe offered shall bear ISI marking with License number. ISI license issued by Bureau of Indian Standard to the manufacturer for the offered pipe shall be attached.)
1700
-
-
... More
Supply of outdoor Copper 3 Core 2.5 Sqmm Annealed Bare Electrolytic Grade Copper Conductor as per IS: 8130/84, Galvanized Steel Wire armored dimensions as per table-5 of IS:1554 Part-1 as per BIS/ISI standards
1600
-
-
... More
Supply and installation Indoor 9U rack Conforms to DIN 41494 OR equivalent ISO Standards Depth of the Rack (mm) Upto 450, Mount Type Wall mount, Type of glass used in front door Transparent Toughened Glass, Material used for rear door SPCC Quality Cold Rolled Steel Metal, Vertical & Horizontal managers, Number of Fan For Heat dissipation ( 1 nos), power strip -Indian- with 4 Sockets with surge protector, each socket supports 230V, 5A
3
-
-
... More
Supply and installation Indoor 32U rack CRCA Steel Floor Standing Network Rack/Cabinet made of Aluminum with Powder coated finished and it has castors wheels to move easily. Conforms to DIN 41494 or Equivalent EIA/ISO/EN/CEA Standard, Tempered glass front door, Adjustable 19" Mounting Rails with lock and key, PDU power strips Number of Fan For Heat dissipation (nos) 4, Heavy Duty Caster Wheels
6
-
-
... More
Supply and installation Outdoor CAT6 cable Inner jacket material : PVC, Storage temperature range : -20 deg.C to +60 deg. C, Cable category : CAT6 UTP - Outer Jacket HDPE with UV resistant, Conductor diameter : 0.57 mm (23 AWG)Maximum DC resistance - in Ohm/Km Max. 100 Ohm/Km Conductor Material Bare Copper Conductor Insulation Material Polyethylene
3
-
-
... More
Supply and installation of 2KVA UPS Rating in KVA (KVA) : 2.0 KVA, Technology : MOSFET-PWM with inbuilt isolation transformer, Input Power : single phase 160V - 260V sinewave,50Hz, Output power : Single phase 230V +/-1% sinewave 50 Hz, Backup time (Minutes) : 60, Minimum VAH (VAH) : 3200, Degree of Protection : IP21 Cabling 5 meters for input and out put : With Paralleling kit for synchronizing : With Type of Battery : SMF-VRLA conforming to JISC:8702(Pt.I,II&III) 20% Overload limit for : Yes minimum 10 minutes Overall Efficiency (%) : /=90% 50% Overload limit for minimum 1 minutes : Yes Maximum overshoot and Under shoot of output rated voltage 4 Voltage Regulation from no load to full load (%) / = 3% 20% Overload limit for minimum 10 minutes Yes Overall Efficiency (%) /=90%, Total Harmonic Distortion(THD) (%) Maximum 3% 50% Overload limit for minimum 1 minutes Yes, As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Monitoring software for Battery, health of UPS, any critical parameter change Communication SNMP V1/V2/V3
3
-
-
... More
Supply of 0.6KVA UPS with Inverter Efficiency (%) : 70% or better, Minimum Guaranteed Battery Backup time (Minutes) on Full Load : 15, Technology MOSFET-PWM, Type of battery SMF-VRLA confirming to JISC-8702 Pt 1,2 &3, Degree of protection IP21, Rated Output (Volt) with Total Harmonic Distortion(%) Single Phase Sinewave 230v AC 50Hz with Total Harmonic Distortion as 3% Input (Volt) Single Phase AC (160-280V) Salient Features Maximum 10 milliseconds Switching over time, Load Power Factor /=0.6,+/-10%Variation in output voltage in battery mode,/=0.5 Hz Variation on output frequency in battery mode, UPS shall withstand 10% overload for at least 10minutes in mains mode, UPS shall withstand 10% overload for at least 5 minutes in mains mode, Variation in AVR output in AC mode (AVR Voltage regulation) 230 Volts +/-9% Protection Under voltage Protection (Input Voltage 160 V), As per Meity (Government of India) guidelines UPS shall have valid IS16242-Part 1CRS certification
3
-
-
... More
Supply of SC to SC fiber patch cord Connector insertion loss (max) 0.3 dB, Connector return loss (min) 55dB,material-Zirconia ceramic, preraisued and prepolished, cable type-simplex, single mode 9/125micron, cord length-3 mtr
50
-
-
... More
Supply of LC to SC fiber patch cord Connector insertion loss (max) 0.3 dB, Connector return loss (min) 55dB,material-Zirconia ceramic, preraisued and prepolished, cable type-simplex, single mode 9/125micron, cord length-3 mtr
50
-
-
... More
Supply and installation of Industrial Grade Layer 2 gigabit managed Network Switch for outdoor applications RJ45 Ports Min. 8 Nos of RJ45 ports that are fully IEEE 802.3 compliant, Fibre Optic ports Min. 2 no. of 1000Mbps fibre optic ports for distances up to 10 km Transceivers SC or LC style . The required gigabit DDMI feature BIDI SFP 10Km BXU-2 Nos. and BXD- 2 Nos. SFP to be supplied.
73
-
-
... More
supply and installation of 19 inch 1U powder coated steel rack Mountable Fiber Optic Patch Panels (Pre-Loaded) for Fiber Cabling with splices and terminations and panel with rubber grommet, SC Type of Connector ,No. of ports (in Nos.)12, with all Mounting kit /Bracket, Cable ties, Mounting Ear Screw, Cable entry Gland, Fiber Management clip, Cable Grounding kits, Port Caps
25
-
-
... More
supply and installation of outdoor point to point wireless bridge Type of Bridge : Point to Multi Point, Antenna Gain (dBi) : 29, Number of Radios : Single, Frequency Band in Ghz : 5.0, Supported Wi-fi Standards : 802.11 b/g/n ,802.11 ac,802.11 ac Wave 2, Wireless Speed Maximum(Throughput) (mbps) : 300, Wireless Signal Range upto(Km) : 5, Receiver Sensitivity {in (- )dBm } : -90, Transmit power (tx) (dBm) : 27, On Site OEM Warranty (Year) : 5
10
-
-
... More
Supply & laying of suitable ISI standard GI pipe in road crossing by road cutting to a depth of 300 mm and laying of GI and finishing with concrete to the road level Necessary rubber bushes to be provided in the ends of the GI pipe for easy movement of OFC cables and to prevent rodents G.I. pipes should be of medium duty class having diameter of 65 mm./40mm. The G.I. Pipes should conform to IS 554/1985 (revised upto date) IS 1989 (Part-I), 1900 Sockets (revised upto date) & IS 1239 (Part-II) 1992 (revised upto date).
125
-
-
... More
Laying of CAT6 cable in suitable PVC pipe of 2mm thick ISI mark with GI clamps as per site condtion. Necessary bend and accessories is in the scope of contractor.
2400
-
-
... More
Laying of HDPE & OFC cable in trench by excavating earth at a depth of 1 mtr Necessary cushioning and cable should be covered for protection and refilling the trench or by HDD with blowing of OFC and make good.
5350
-
-
... More
Laying of OFC cable & HDPE pipes inside the cable duct by lifting the concrete blocks trench behind green gate entrance and after laying of cables inside duct the concrete blocks to be arranged to avoid hindrance for pedestrian movement
500
-
-
... More
Laying of HDPE pipes in the fencing with proper clamping including laying of OFC cable/power supply cable/cat 6 in the HDPE pipe by pulling or blowing
500
-
-
... More
Installation of CCTV cameras in wall/ with necessary mounting plate and required fabrication works in the GI pole as directed by the Engineer in charge (Fixed cameras- 73 Nos. PTZ camera-8 Nos.)
127
-
-
... More
Supply and installation of 6 mtr GI pole with Height 6000mm(5000mm pipe OD 114x3mm thick,)+1000mm pipe OD 48x3mm thick), base plate 250mmx250mmx12mm thickness, thickness of pipe size OD 48x3 mm thick, top pipe to be closed with plate to prevent dust/water getting into pipe. The pole to be installed with suitable concrete foundation pedestal for grouting /fixing the GI structure. Necessary fabrication works for holding the CCTV cameras, painting, making cable entry arrangements is in the scope of contractor.
47
-
-
... More
Supply and installation of Weather proof outdoor Outdoor network distribution cabinet of IP 65, 600 X 600 X 350 (H X W X D mm) size Rack type JB with 2 nos Double pole MCB, 4 nos (3 pin) Female Socket with mounting box , Cable route tray with accessories for installation of LIU, Media Convertor , PoE Injector , Network Switch, Power Supply. It also includes supply and installation of required stand arrangements for box, cable glands and TBs for termination of Power Cables. Necessary Earthing should be as per RDSO Specification No. RDSO/SPN/197 (Version-1.0) or latest
54
-
-
... More
Supply and installation of Weather proof outdoor Outdoor network distribution cabinet of IP 65, 600 X 600 X 350 (H X W X D mm) size Rack type JB with 2 nos Double pole MCB, 4 nos (3 pin) Female Socket with mounting box , Cable route tray with accessories for installation of LIU, Media Convertor , PoE Injector , Network Switch, Power Supply. It also includes supply and installation of required stand arrangements for box, cable glands and TBs for termination of Power Cables. Necessary Earthing should be as per RDSO Specification No. RDSO/SPN/197 (Version-1.0) or latest
8
-
-
... More
Supply and installation of Server / Workstation for Video Management & Recording of 250 Cameras -Processor Latest Generation x86 Intel / AMD Processor, Minimum 8 Cores in Single Processor or 2 nos. of 4 Core Processor (Dual Socket),2 Threads per Core, 2.1 GHz or higher,16 GB or higher, DDR4 SDRAM or latest, Windows Operating System or Linux, latest with Client licenses , Onboard/ on slot Gigabit Ethernet (RJ45) with Load Balancing and Fail over Support, IPv6 compliant. (Minimum 2 nos. of 1G ports should be available), Hot Pluggable Enterprise SATA HDDs / Hot Pluggable SSD or SAS (10000 RPM or higher for SAS) HDD, higher internal drive bays hard disk required for storing 250 cameras for 90 days storage. Hardware based - SATA / SAS / SSD - RAID Controller with RAID 0/1/5 configuration, DVD R/W Drive (internal) & USB Ports Dual and Redundant Power Supply,19” Rack mountable with sliding rails and fittings to install into a Rack, BIS/UL/EN/CE/IEC certification for Safety and BIS/CE/FCC Certifications for EMC & Immunity. Network Video Management software shall be Failover Support, Multicasting and Multi-streaming, NAT Firewall Support, Watchdog, VMS Client Viewer (Operator) Features, Video Content Analytics (VCA), NVMS OEM should have the Following Certificates: ISO 9001, 27001, ISO 14001, CMMI Level-3, The offered NVMS should be ONVIF Profile S,G,Q &T compliant and Quoted model should be listed on ONVIF Site. The NVMS shall have capacity for viewing 250 cameras. The existing 120 cameras of Port also recorded with the new 127 cameras supplied. Necessary smart rack of IP-54 with Cooling Solution, Fire Detection & Suppression Systems, Monitoring system with sensors for Temperature & Humidity Sensor, Water Leak Detector, biometric Access Control system for the work station shall be supplied and installed by the contractor in DC & DR site. Necessary power backup for not less than four hours for the server in CCTV control room and Traffic control room is in the scope of contractor. The Server / Workstation for Video Management & Recording, Core Switch, Aggregation Switch, Layer 2 Switches (24 ports) shall comply with RDSO Specification RDSO/SPN/TC/65/2019 Rev. 5.0 with latest Amendment
1
-
-
... More
Design and commissioning of an industry standard Enterprise Management System (EMS) for monitoring of all the assets of VMS System (including all IP devices of VSS System like Cameras, Storage, Servers, Switches, UPS etc.) are required to be monitored. EMS System to be deployed at one Data Center as a DC with the redundant infrastructure configured in other Data Center as a DR, in case of failover. There will be a continuous data replication & synchronization from DC to DR site on daily basis to prevent a loss of configuration changes in the event of losing the production instance. Daily report of status of IP camera(working/non working), storage data available, events for non storage of videos for particular camera etc to be generated in pdf/excel format i) The EMS Solution (Hardware & Software) shall provide monitoring of 1000 network IP devices from day 1 with future scalability without major architectural changes. Whenever required, the additional device licenses can be procured & added respectively.
ii) Solution shall be open, distributed, scalable, and multi-platform and open to third party integration. Consolidate IT event management activities into a single operations bridge/dashboard that allows NOC operator quickly identify the cause of the IT incident, reduces duplication of effort and decreases the time it takes to rectify IT issues. Consolidated dashboard of the proposed EMS solution shall be the manager of managers window and capable of receiving events/alerts from multiple monitoring systems including system, network, storage, hardware, and application.
iii) Consolidated Dashboard Tool should provide superior view of infrastructure health across system, networks, IT infrastructure and end-user into a consolidated, central console.
iv) Service Level Reporter- Reports should be accessible via web browser, Reports can be scheduled to publish automatically or they can be produced on demand. Reports can be published in HTML, PDF, Microsoft Word, and Microsoft Excel formats.Tool should allow to configure downtime for Configuration Items and view the configured downtime in the reports.
v) Network Automation-Should be able to generate a graphical representation of your network. Identify which devices are inactive or out of compliance. Detecting noncompliance, issuing alerts. The ability to compare configurations is invaluable;
system changes must be logged. In real time, detect configuration and asset information changes made across a multi-vendor device network, regardless of how each change is made and also support configuration deployment/rollback and configuration templates. Recording every access to a device including not only scripted and automated access, but a full keystroke log. Who made what change, the reason for the change and associated ticket number must be captured. Manage dual-stack and pure IPv6 environments. Manage SNMPv3 configurations and communicate over SNMPv3.Manage device access and authorization through a centralized control model that is integrated with your standard workflow and approval processes. The system must support heavily NAT environment and environments. where network devices may have the same IP address. The system must provide an automated method to configure devices for real-time change detection via syslog (either direct syslog or syslog via a relay).
1
-
-
... More
Developing Mobile App for viewing CCTV Videos and other applications in Android and uploading in play store. The sufficient hardware requirement for the seamless streaming of the video through app to be provided. Six Nos. of Wifi Access points with wifi controller shall be supplied by the contractor including necessary firewall licenses. Wifi Access points to be installed in Port administration building. The App shall be working with local wifi units installed in Port administrative building. Based on the bandwidth requirement calculation required for the app the internet connectivity shall be provided by VOCPA. The wifi controllers should be scalable as licenses are purchased and deployed and ready from day one to support 100 AP’s without additional hardware / software. The controllers should support minimum 30 users/devices The controllers should be compliant to latest wireless standards of 802.11ax and should also support 802.11 a/b/g/n/ac versions The controllers should be SNMP enabled.The controllers shall be manageable by CLI using SSH protocol and HTTPS based GUI and should be SNMPv2/v3 enabled from day one. wifi Access Point radio should be minimum 2x2:2 (2.4GHz) 4x4:4 (5GHz). The AP should have Dual Radio 802.11ax access point with OFDMA and Multi-User MIMO (MU-MIMO) Access point should support 802.3af/at POE standard.
1
-
-
... More
Carrying out necessary Civil reconditioning works in the existing CCTV control room for fixing of LED TV for proper viewing and in Traffic control room for DR site with necessary raised floor design. Total area of Traffic control room for DR site is 39 Sqmtr. FALSE FLOOR: The system modular panels with heavy-duty pedestals. PANEL: Panels shall be made of steel with an infill of lightweight, non-combustible having fire resistance, thermal insulation, and flame resistance properties at 60 min cementitious material. The False Floor System shall be tested as per CISCA standards for Point Load, Uniform Load, Ultimate Load and Pedestal Axial Load. Test reports from an accredited laboratory to be furnished
1
-
-
... More
Splicing for termination of OFC cable
800
-
-
... More
CAMC for four years for the BOQ Sl.No.16 &17 including engaging necessary networking staff to be in round the clock for the maintenance of the system Minimum one networking staff to be present in a shift basis daily.
16
-
-
... More
Charges for engaging suitable CCTV technicians for day to day maintenance works in all the CCTV camera installed in Port Minimum a two technicians to be present in a shift basis daily.
16
-
-
... More
Supply and installation of mid hinged foldable pole GI pole with Height 4000mm top pipe to be closed with plate to prevent dust/water getting into pipe. The pole to be installed with suitable concrete foundation pedestal for grouting /fixing the GI structure. Necessary fabrication works for holding the CCTV cameras, painting, making cable entry arrangements is in the scope of contractor.
5
-
-
... More
Supply and installation of 64 Channel NVR with 80TB hard disk Number of Video Input channels 64 Recording Resolution12 MP (4000 X 3000),Type of recording device=NVR Number of Video Input Channels64, Number of Video Output Channels=64, Recording Resolution12 MP (4000 X 3000), Supported Compression Technique H.264, H.265, MJPEG, H.265+, Maximum Number of cameras to be viewed on a single display=64, Total number of simultaneous local views=4, Simultaneous Monitoring Connections for All Cameras (Users in Local Network for Client Connection) 16,Recording Speed for all channels (fps) 25, Minimum Through put (Mbps)640 Display Image Rate Real time per channel, Type of Recording Device NVR, IP Camera Support Yes PTZ Camera control Support Yes, Housing construction Aluminum Mounting Rack Mounted, Capability of Recorder to Work with Other Makes of CCTV Cameras (ONVIF support) Audio Support , Audio Input 1, Audio Output 2 Audio Compression G.711,U-Law,A-Law Minimum Number of Simultaneous Channels for Two-way Audio Support 1 Type of Encryption HTTPS (SSL/TSL),HTTP (SSL/TSL), Multi Level User ID / Password Alarm Support , Alarm Input16, Alarm Output 4, Pre / Post Alarm Buffe Yes, Post-Alarm Recording 60 second, Video Content Analytics (VCA) Trip-wire Detection, Motion Detection, Crossing line, Intrusion Detection, Object counting, Tampering, Object Removal, Video Loss, INPUT TRIGGER, IP CAMERA CONNECTION,THIRD PARTY ALARM INTEGRATION, PERIMETER,OBJECT ABANDONED/ REMOVED Operating System Supported Windows /Linux Supported Network Protocols- UDP, SNMP, IGMP, DHCP, RTP, HTTP, HTTPS, DNS, DDNS, RTSP, RTCP, NTP, UPnP, SMTP, FTP, ICMP, QoS, TCP/IP Supported Interface Ethernet, HDMI, VGA, USB,RS 232,RS-485,8 HDD SLOT Physical Layer of Ethernet 10/100/1000 Base TX Number of Ethernet Ports=2, Number of HDMI Ports=2, Number of VGA Ports2 Number of Serial Ports= 2, Video Loop Support, Video Recorder supports recording on NAS Directly, Remote Administration (Remote Configuration And Status Using Web Based Tool) System Update (Remote System Update Over Network Using Web Client), PC Client (PC Application Client With A Channel Recording Feature Support), Web Client (Viewer through HTTP system configuration), On Screen Display , Drivers / Compatible Software (Wherever Applicable) Part Of Supply Recording schedule support ALONG WITH MOTION BASED, ALARM BASED, FREE RUN 24 *7, EVENT BASED, ANALYTICS BASED Bandwidth Control, Camera Notification Spot (POP up Window) on Event, E-mail Network transmission Speed Real time display @ D1 resolution, Synchronous Playback up to 16 Ch full HD,, Constant Bit Rate (CBR),Variable Bit Rate (VBR), Other features, if any e-SATA & P2P Search Date, Time, Event, ,Motion, Bookmarks, Thumbnail, ALARM, Alarms Bookmarks Forward, Backward, adjustable playback speed, Full Screen, Next Camera, Previous Camera, TAGGING Page preview Multi Monitor Support, Video Window, Video matrix, Event monitor, Alarm monitoring window Total Management Group add, Delete, Group management, ALARM MANAGEMENT,USER MANAGEMENT,EMAIL VERIFICATION,STORAGE Camera Add, Edit, Delete, Use Master account, Use Specific account Internal Hard Drive Interface SATA III, Number of Hard Disks (inclusive in the scope of supply8 Nos. Storage Capacity of each Hard Disk (TB)10, Total Storage Capacity(TB)80, Internal Storage Expandable upto (TB) 80, Number of Hard Disks supported8 Redundancy Option RAID 5, Power Input 230 ± 10%, 50Hz,100 to 240 VAC Suitable Adapter to be Supplied to Make the Equipment Work on 230 V, ± 10 %, 50 Hz Yes, Minimum Operating Temperature-10 degree Celsius, Maximum Operating Temperature55 degree Celsius, Relative Humidity Non Condensing at 40 deg C90 percent, Availability of facility and infrastructure for verification of all the parameters, features and capability with the Seller Conformity to Dry Heat test at Specified Maximum Operating Temperature for 16 hours as per IS :9000 latest Conformity to Damp heat at 40 degree C - 95% RH (cyclic test): two cycles of 16+8 hours as per IS: 9000 latest Conformity to Cold test at Specified Minimum Operating Temperature for 4 hours as per IS: 9000 latest BIS Registration for safety general requirements as per IS: 13252 (Part 1): latest Availability of Test Report from Central Govt/NABL/ILAC accredited lab to prove conformity to specification Yes Test Report Number and Date180605045GZU111018 Name and Address of Test Lab Intertek UK CertificationFCC,CE,UL,EN61000-3-2,Security immunity (EN55024),emissions FCC part 15;,EN55032;,UL/BIS, BIS"
1
-
-
... More
RJ45 modular plug supports 4 twisted pairs 8P8C type of connector Contact Terminal: Copper Alloy Finished: 03MU micro-inch gold plating Use for 24-26 AWG stranded wires meet wiring scheme T568A/T568B
500
-
-
... More
Supply of Cable category : CAT6 Supports Gigabit Ethernet (1000 baseT) standard. Operates at bandwidth of 250 MHz. Cable will be compliant to TIA/EIA-568-C.2 Conductor: Solid Bare Electrolytic Grade Copper Armouring: Aluminum Wire, Insulation: Polyethylene Conductor Diameter: 23 AWG, Filler: HDPE UV resistant for outdoor and/or direct burial installations
915
-
-
... More
Supply of Cable category : CAT6 UTP – Outer Jacket HDPE with UV resistant Conductor diameter : 0.57 mm (23 AWG) UL Marking on Cable : Yes Conductor Material Bare Copper Conductor Insulation Material Polyethylene Inner jacket material LSZH Conductor stranding Solid Cable should have internal cross separator Cate 6 cable (Out door use) conforming to TIA/EIA-568 C.2 or ISO/IEC:11801 latest UV resistant for outdoor and/or direct burial installations
915
-
-
... More
Supply of CAT6 U/UTP Patch cord 3.0 Mtrs, Cable jacket material : Fire retardant PVC UL Marking on Cable : Yes Cate 6 patch cord conforming to ANSI/TIA/EIA-568 C.2 or ISO/IEC:11801 latest Conductor diameter 24 to 26 AWG Termination type / Connection type Insulation Piercing Connection (IPC), Modular plug RJ45 Plug insertion durability ≥ 750 mating cycles, Conductor Material Stranded copper Conductor Insulation Material Polyethylene
100
-
-
... More
Supply of Fibre count : 24, Jacket material : HDPE , Fibre type : Single mode OS2 Fibre cable generally conforming to IEC 60793- 1, IEC 60793-2, and to conform other normative specifications as specified in IEC:60793 Part 1 and Part 2 Nominal Cable weight Kg/Km - Must declare 140 Maximum Crush Resistance(short) 2000N Maximum Crush Resistance(long) 63 lbs/in (110 N/cm) Minimum Bend Radius(installation) 20 X OD Minimum Bend Radius(in service) 10 X OD Max Tensile load Short term: 2700N Single Mode Optical Fiber used in manufacturing optical fiber cables shall be as per ITU-T Rec. G 652 D
4700
-
-
... More
Supply of permanently Lubricated HDPE Telecom Ducts for use as underground optical fibre cable conduits The HDPE pipes suitable for Optical Fibre Cable is pull through 40mm outer diameter PLB Pipes/Coils having strength of 10 Kg/sq. cm. Necessary HDPE socket, PR rope, PLB end caps To prevent entry of rodents into PLB pipes, the ends of PLB pipes are sealed at every manhole and joint using rodent resistant hard rubber bush (cap) after optical fibre cable is pulled. HDPE pipe as per specification RDSO/SPN/TC/45/2013 HDPE pipe: ISI approved HDPE pipe. The pipes shall be supplied with ISI mark on each pipe. (The pipe offered shall bear ISI marking with License number. ISI license issued by Bureau of Indian Standard to the manufacturer for the offered pipe shall be attached.)
4700
-
-
... More
Supply and installation of Wall Display Lamp /Light Source : LED, Diagonal Screen Size (cm) : 135 or higher Horizontal Resolution (Pixel) : 3840, Vertical Resolution (Pixel) : 2160 Bezel to Bezel Width (mm) : 3.5, Brightness (nits) : 500 Panel Technology IPS, Dimension (LxWxD) (mm x mm x mm) 2426.8 x 1368.4 x 93 Horizontal Resolution (Pixel) 3840, Vertical Resolution (Pixel) 2160 Bezel to Bezel Width (mm) 3.5, Contrast Ratio (Static) 1200:1 , Aspect Ratio 16 : 9, Response Time (mill sec) 8 millisecond, Viewing Angle (Degree) 178, Display Color/Color Depth (Billion), 1.06 Brightness (nits) 500, Uniformity of brightness, across the screen (%) Minimum 90, Light output of Projection Engine (Lumens), 500 lumen Life of light source (Hours) 50000 hour Number of DVI-D Input Port 4 Number of HDMI Input Port 8 Data wall controller available with minimum 4 input port(DVI/DP) BIS Registration under CRS of Meity Accessories to be supplied (Like User Manual, Software CD, Power Cord, Remote Control etc) Remotes & cables
5
-
-
... More
Supply and installation of LED Tv 32 Inch Smart TV Resolution (Pixels) : (1366 x 768) HD Ready Typical Brightness : 300 - 399 Mount Type Both table and wall mount Number of HDMI Ports 3, Number of USB Ports 2, Number of Ethernet Ports 1 , Built-in Wi-fi, Wi-fi Direct, Details of accessories (included in the scope of supply) Remote Control, Connecting Cable, Batteries, BIS Registration as per CRS of Meity
2
-
-
... More
Supply and installation of 9U rack Conforms to DIN 41494 OR equivalent ISO Standards Depth of the Rack (mm) Upto 450, Mount Type Wall mount, Type of glass used in front door Transparent Toughened Glass, Material used for rear door SPCC Quality Cold Rolled Steel Metal, Vertical & Horizontal managers, Number of Fan For Heat dissipation ( 1 nos), power strip -Indian- with 4 Sockets with surge protector, each socket supports 230V, 5A, Load Bearing Capacity (Kgs) 25 kilogram
2
-
-
... More
Supply and installation of nDIN-rail L2+ Ring Managed Gigabit PoE Switch IP30-rated Metal Industrial Switch, Type of Switch : L2 Managed Technology : PoE+ Number of 1G Copper Ports : 8 Time Synchronization IEEE1588v2, Basic Protocol : DHCP Server / Client / Relay Switching Capacity -Non Blocking (Gbps) : 20 Console Port : Yes MAC Address table(Thousand) : 8 Fanless design : Yes Automation Profiles : Profinet Installation : DIN rail Dual power input for redundant power supplies ( from day one) : Supported IPv6 Ready from day one Power Input Option : AC ,DC ,AC-AC ,AC-DC ,DC-DC Reverse Polarity Protection Basic Layer-2 Protocol : Protocol based VLAN Certifications : Freefall or drop ,Vibration ,Shock No. of 1 G SFP Port (Uplink) : 2 Security Feature SSLv2 PoE Power Budget ( Watt ) 225 IEEE 802.3 10BASE-T IEEE 802.3u 100BASE-TX/100BASE-FX, IEEE 802.3ab Gigabit 1000T IEEE 802.3z Gigabit SX/LX, IEEE 802.3bz 2.5GBASE-X, IEEE 802.3x flow control and back pressure, IEEE 802.3ad port trunk with LACP, IEEE 802.1D Spanning Tree Protocol IEEE 802.1w Rapid Spanning Tree Protocol, IEEE 802.1s Multiple Spanning Tree Protocol, IEEE 802.1p Class of Service, IEEE 802.1Q VLAN tagging IEEE 802.1ad Q-in-Q VLAN stacking, IEEE 802.1x Port Authentication Network Control IEEE 802.1ab LLDP, IEEE 802.3af Power over Ethernet, IEEE 802.3at Power over Ethernet Plus, IEEE 802.3ah OAM, IEEE 802.1ag Connectivity Fault Management (CFM) IEEE 1588 PTPv2, RFC 768 UDP, RFC 793 TFTP, RFC 791 IP, RFC 792 ICMP, RFC 2068 HTTP, RFC 1112 IGMP v1, RFC 2236 IGMP v2, ITU-T G.8032 ERPS Ring ITU-T Y.1731 Performance Monitoring. Equivalent model IGS-10020PT. The required gigabit BIDI SFP 10Km BXU-2 Nos. and BXD- 2 Nos. SFP to be supplied.
30
-
-
... More
Supply and installation of Single Mode Full Duplex Auto Sensed Fiber Media converter, Speed, Mbps : 1000 Sensor : Full Duplex Auto Sensed, Maximum Transmission Distance : 10 kilometer Mode : Single Mode Supports flow control and reduce broadcast packets ,Flow Control :Full Duplex: Flow Control Supporting Packets VLAN, VoIP, QoS, Mounting Type Din-Rail, Network Media Converts 1000 Base -T to1000 Base - LX, Standards and Protocols IEEE802.3 10 Base-T Ethernet,IEEE802.3u 100 Base- TX/FX Fast Ethernet, IEEE802.3ab, IEEE 802.3z, IEEE 802.3x
30
-
-
... More
Supply of Line Interactive UPS with AVR of Rating 1.0 KVA Technology : MOSFET-PWM, Minimum Guaranteed Battery Backup time (Minutes) on Full Load : 15, Inverter Efficiency (%) 60% or better, Type of battery SMF-VRLA confirming to JISC-8702 Pt 1,2 &3, Enclosure ABS, Degree of protection IP 20 Rated Output (Volt) with Total Harmonic Distortion (%) Single Phase Quasi Sinewave 230 V AC 50 Hz with Total Harmonic Distortion as =40% Input (Volt) Single Phase AC (160-280V) Salient Features Load Power Factor /=0.6 Variation in AVR output in AC mode (AVR Voltage regulation) 230 Volts +/-9% Protection Under voltage Protection (Input Voltage 160 V),Overvoltage Protection (Input Voltage280V),Short Circuit of UPS, Low Battery, Overload As per Meity (Government of India) guidelines UPS shall have valid IS16242-Part 1 CRS certification, Monitoring software for Battery, health of UPS, any critical parameter change Communication SNMP V1/V2/V3
15
-
-
... More
Supply and installation of Online UPS of Rating 2.0 KVA with Battery of Backup Time 120 Minutes Switching Technology : IGBT-PWM, Rating in KVA : 2.0 KVA, Input Voltage AC Single phase 160V - 260V 50Hz, Output Voltage AC Single phase 230V +/-1% 50 Hz, SMF-VRLA conforming to JISC:8702(Pt.I, II&III), Stationary Lead Acid Batteries (with tubular positive plates) in monobloc container conforming to IS:13369:1992 latest, Minimum Guaranteed VAH 1600 X Per KVA X Per hour of backup time, Battery recharge time (after complete discharge to 90% charge) and charge rating: Battery recharge time to 90% charge after 100% DoD : 8 to 10 Hours, Crest factor on full non-linear load is not less than 3:1,Input power factor at full output load leading to unity with active power factor correction (APFC) /=0.92,Maximum overshoot and Under shoot of output rated voltage (in percentage) (4%), Noise level (1 meter distance from UPS) should be less than 70dB, output must remain within +/-1% and recovery) as 20 milliseconds, Transient response time (for 100% load change, Voltage Regulation from no load to full load (%) ( / = 2%) Pure Sinewave AC Output Type Test Report as per relevant governing specifications from Govt Lab/NABL accredited lab Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs, Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) at 55 degree C for 16 hrs, Damp Heat Test : in accordance with IS:9000(part 5/sec.2)1981 at Temperature of 40 degree C Monitoring software for Battery, health of UPS, any critical parameter change Communication SNMP V1/V2/V3
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements