V O Chidambaranar Port Trust Tender

Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.

V O Chidambaranar Port Trust Tender

Works
Civil And Construction
Road Construction
Eprocure
Opening Date13 Dec 2024
Closing Date2 Jan 2025
Tender Amount₹ 9,88,74,449 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor,compacting with 8-10 tonnes vibratory roller, finishing and curing etc,.complete and as directed by the departmental officers.

2980

-

-

... More
Providing and Laying of Debonding Layer of 125 micron PVC sheet for road construction including overlaps over the upper sub-base including cost of materials & laying chargesetc,.complete and as directed by the departmental officers.

19420

-

-

... More
Construction of un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with 43 grade cement @ 400 kg per cum, coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design (M40), transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of admixtures as approved, finishing to lines and grades etc., complete as per clause 602 of MoRT&H specification and as directed by the departmental officers

5820

-

-

... More
Providing and laying Plain Cement Concrete 1:1.5:3 (One part of cement, One and a half parts of Coarse sand & Three Parts of graded stone aggregate (i.e.) 2 parts of 20mm nominal size graded metal & 1 part of 10mm nominal size graded metal) for RCC works using 20 mm nominal size graded metal including mixing, laying, levelling, consolidation, finishing and curing etc., complete complying with AISS and as directed by the departmental officers

1220

-

-

... More
Fabricating and placing in position of M.S / Tor steel grills for R.C.C works in all floors including cost of Steel, cutting, bending, binding with 16 Gauge GI Binding wire and placing in position etc., complete complying with AISS and as directed by the departmental officers.

77

-

-

... More
Providing Form work including centring, shuttering for foundation footings of columns, mass concrete so as to give a rough finish shuttering and propping etc., complete complying with AISS and as directed by the departmental officers.

12740

-

-

... More
Providing and fabricating 38mm dia MS bars and placing in position as dowel bars for expansion joints as per details shown in the drawing and as directed including all handling, cutting, bending, all labour, materials, equipment, tools etc., complete. Dowel bar of length 500mm for expansion joints (one half of the rod painted with bitumen and greased to avoid bonding with concrete) including providing necessary PVC sleeve & cap, cotton waste @ 300mm c/c etc., complete and as directed by the departmental officers.

11420

-

-

... More
Supplying and laying impregnated bitumen pad of 20 mm thickness and 275 mm depth approximately) for expansion joints to the required length as specified in the drawing and as directed including making necessary holes in the pad and fixing the same in to the dowel bars all labour, materials, transportation, tools, equipment etc., complete and as directed by the departmental officers. Note: 1.The rate shall include making necessary holes in the pad for fixing the same in to the dowel bars. 2.The joint filler shall comply with IS 1838 - 1983 or its latest edition.

980

-

-

... More
Supplying and laying bitumen sealing compound of grade 'A' conforming to IS 1834 # 1984 (or its latest edition) for Expansion joints as per details shown in the drawing, including painting the edges of the joint with an approved primer all as specified and as directed at site of work including all materials, labour, tools, equipment, fuel, etc.,complete and as directed by the departmental officers.

3400

-

-

... More
Supplying and laying bitumen sealing compound of grade 'A' conforming to IS 1834 # 1984 (or its latest edition) for Longitudinal joints and Contraction joints as per details shown in the drawing, including painting the edges of the joint with an approved primer all as specified and as directed at site of work. including all materials, labour, tools, equipment, fuel, etc., complete and as directed by the departmental officers.

3260

-

-

... More
Providing and laying of Hot applied Thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms. per Sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC :35 for centre line and edge line. The finished surface to be level, uniform and free from streaks and holes etc., The rate including cost and conveyance of all materials, labour, incidental charges, marking for applying paint, brushes, equipments etc., complete as per MORTH Specification No.803 and as directed by the departmental officers.

1230

-

-

... More
Providing and fixing Reflective Road Studs of 'Category - A' Raised pavement markers made out of poly carbonate / methyl methecrylate/ABS mouled body confirming to ASTM D 788 and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face with retro reflectance and chromaticity values conforming to ASTM D 4280. The reflective raised pavement markers shall also confirm to the MORTH corcular No RW / NH 33023 / 10 / 97 - DO.III, dt 11.06.97. The height, width and length shall not be less than 15mm, 90mm and 100mm and with minimum refelctive area of 13 Sq.cm. on each side and the slope to the base shall be 35 +/- 5 degree. Each reflector shall have a CIL not less than values specified in Table 2 of said MORTH circular. The strength of detachment of the integrated cylindrical shanks, (of dia not less than 19 +/- 2 mm and height not less 30 +/- 2mm) from the body is to be a minimum value of 500 Kgf. Fixing will be by drilling holes on the road for the shanks to go inside, without nails and using epoxy resin based adhesive as per manufacture's rercommendation and complete as directed by the engineer. The marker shall support a load of 13635 Kg. tested in accordance with ASTM D4280 and confirming to IRC 35 - 2015 guidelines and MORTH specification 804 etc., complete. The cost inclusive of studs and other tools and plants fixing materials drilling holes etc., complete as per MORTH Specification and as directed by the departmental officers.

1620

-

-

... More
Supplying and installing of Delineators (road way indicators, hazard markers and object markers), 80-100 cm high above gound level painted at alternatively black and white in 15cm wide strips, fitted with 80x100 mm rectangular or 75mm dia. circular reflectorised panels at the top, buried or pressed into the ground and conforming to IRC-79 etc., complete as per MORTH Specification No.806 and as directed by the departmental officers.

180

-

-

... More
Plastering the Brick work 15 mm thick in Cement Mortar 1:5 (One cement, five sand) for all faces of walls (even and uneven) in all floors upto full height of the building including necessary scaffolding, racking of masonry joints, cleaning, curing etc.,complete complying with AISS and as directed by the departmental officers.

600

-

-

... More
Painting the Floor surfaces with Two Coats of Synthetic Enamel Paint of approved quality (excluding priming coat) on previously painted concrete / masonry / plastered surfaces with ready mixed paint brushing for use on floors to give an even shade including cleaning the surface of dirt, dust and other foreign matter and sand papering as required including cost of Synthetic Enamel Paint and labour charges etc., complete complying with AISS and as directed by the departmental officers.

11280

-

-

... More
Supplying and laying in trenches 110 mm dia. PVC inflow pipe line 6Kg./CM2 with necessary pipe specials such as elbow, tee, union joint etc., and the joints being tightened including threading cost of pipe, specials etc., complete complying with AISS and as directed by the departmental officers.

4770

-

-

... More
Providing, Supplying and Laying factory made Chamfered edge Cement Concrete 60mm thick Paver block of M-35 grade with approved colour, design & pattern of required strength, thickness & size / shape, made by table vibratory method using PU mould, laid in required colour & patten over 50mm thick compacted bed of sand, compacting and proper embedding / laying of inter locking paver blocks into the sand bedding layer through vibratory compaction byusing plate vibrator, filling the joints with sand and cutting of paver block to the required size and pattern, finishing and sweeping extra sand etc., including all materials, labour, tools & plants, conveyance etc., complete and as directed by the departmental officers.

100

-

-

... More
Filling basement with available excavated earth in trenches, plinth, sides of foundation etc., in layers not exceeding 20cm in depth, consolidating and watering etc., complete complying with AISS and as directed by the departmental officers

530

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.