Tidel Park Limited Tender

Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.

Tidel Park Limited Tender

Services
Civil And Construction
Building Construction
Eprocure
Opening Date8 Aug 2024
Closing Date10 Sep 2024
Tender AmountRefer Documents 
Notes
Download

Costs

Summary

Construction Of It Office Building, Ground Floor Plus 12 Floors Plus Terrace, Including Civil Construction, Interior Finishing Works, Mep Works And Other Allied Development Works At Mattuthavani In Madurai.

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Earth work open excavation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the excavated earth with a lead of 10 mts. within the compound in places shown by the PMC/Employer and clearing and levelling the site, etc., complete complying with standard specification.The item shall include necessary civil works required for ensuring retention of full depth of excavation.

27970

-

-

... More
Earth work excavation for foundation (for narrow excavation) in all soils and sub-soils as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the PMC/Employer with an initial lead of 10 mts and initial lift of 2 mts. and including necessary backfilling in layers of not more than 15 cm thick well rammed, watered and consolidated, clearing and levelling the site, etc., complete complying with standard specification.

6157

-

-

... More
Extra for every additional 1 metre lift or part thereof over the initial lift

770

-

-

... More
Refilling with approved excavated earth available at site and depositing the earth as shown by the PMC/Employer in layers of not more than 15 cm thick well rammed, watered and consolidated etc. complete complying with standard specification. This item shall include rate for all soil testing as specified in standard specification.

21757

-

-

... More
Disposal of surplus earth including loading, conveyance within a distance of 5 km or city limits (basic cost of earth is zero) and disposal of the conveyed earth.

20611

-

-

... More
Supplying and filling in foundation, basement, etc with filling crushed stone sand (suitable earth) in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the PMC/Employer.This item shall include rate for all soil testing as specified in standard specification.

13659

-

-

... More
Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of PMC/Employer 'With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30

2985

-

-

... More
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of PMC/Employer.

200

-

-

... More
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of PMC/Employer

1

-

-

... More
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of PMC/Employer.

1

-

-

... More
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of PMC/Employer, upto 90 metre depth below ground level.

-

-

-

... More
400 mm dia

15

-

-

... More
Supplying and filling of sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the PMC/Employer.This item shall include rate for all soil testing as specified in standard specification.

257

-

-

... More
ANTI TERMITE TREATMENT :

-

-

-

... More
Providing Pre-constructional Antitermite treatment including cost of chemical labour as per standard specification for preparing the area for treatment by spraying chemicals and other incidental charges etc., complete the rates should be for curing antitermite treatment from the plinth beam and brick masonry with super structure in contract with the back fill earth and at the junction of the walls. The top surfaces of filled earth for flooring and the soil along with the perimeter of the building by making holes with the crow bar and poured 5% termicide 'Chloripyrifos' and spraying the same termicide soultion on the wooden frames and treating the other periphery of building etc., Complete in all respects as per IS 6316 (Part II) and as directed by the PMC/Employer.

4940

-

-

... More
CEMENT CONCRETE WORK :

-

-

-

... More
To meet the LEED certification, required ingredients such as fly ash/GGBS to be added in required proportion to meet the strength requirements.

-

-

-

... More
Plain Cement Concrete 1:3:6 (One Cement, Three crushed stone sand and Six hard broken stone jelly) using 20 mm gauge hard broken granite stone jelly inclusive of shoring, strutting, bailing out water, ramming, curing etc. complete in all respect by the PMC/Employer.

575

-

-

... More
Plain Cement Concrete 1:4:8 (One Cement, Four crushed stone sand and eight hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly inclusive of shoring, strutting, bailing out water, ramming, curing etc. complete in all respect by the PMC/Employer.

167

-

-

... More
Plain Cement Concrete 1:2:4 (one cement, two crushed stone sand and four hard broken stone jelly) using 20mm jelly for wearing coat including laying, compacting, finishing and curing, etc., complete as per standard specificatins and as directed by the PMC/Employer.

104

-

-

... More
Plain Cement Concrete 1:5:10 (One Cement, Five crushed stone sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete complying with standard specification

173

-

-

... More
Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20mm nominal size derived from natural sources).

27

-

-

... More
Providing and laying in position, Standardised Concrete Mix M-25 Grade in accordance with IS:456-2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cementcontent of 350 kglms and maximum water cement ratio of 0.50, including admixture (plasticiser / superplasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m') 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the PMC/Employer. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials).

-

-

-

... More
Foundation

1103

-

-

... More
Ground Floor

216

-

-

... More
Providing and laying in position, Standardised Concrete Mix M-30 Grade in accordance with IS:456-2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cementcontent of 400 kg/m3 and maximum water cement ratio of 0.45, including admixture (plasticiser / superplasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m') 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the PMC/Employer. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials).

-

-

-

... More
Foundation and Basement

4211

-

-

... More
Ground Floor

443

-

-

... More
For First Floor

746

-

-

... More
For Second Floor

735

-

-

... More
For Third Floor

1272

-

-

... More
For Fourth Floor

1258

-

-

... More
For Fifth Floor

1274

-

-

... More
For Sixth Floor

1339

-

-

... More
For Seventh Floor

1380

-

-

... More
For Eighth Floor

1318

-

-

... More
For Nineth Floor

1333

-

-

... More
For Tenth Floor

1325

-

-

... More
For Eleventh Floor

1352

-

-

... More
For Twelfth Floor

1388

-

-

... More
For Terrace Floor and Above

1667

-

-

... More
Providing and laying in position, Standardised Concrete Mix M-40 Grade in accordance with IS:456-2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cementcontent of 440 kg/m3 and maximum water cement ratio of 0.40, including admixture (plasticiser / superplasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m') 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the PMC/Employer. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials).

-

-

-

... More
Foundation and Basement

1133

-

-

... More
Ground Floor

720

-

-

... More
For First Floor

391

-

-

... More
For Second Floor

391

-

-

... More
For Third Floor

317

-

-

... More
For Fourth Floor

317

-

-

... More
For Fifth Floor

319

-

-

... More
For Sixth Floor

256

-

-

... More
For Seventh Floor

256

-

-

... More
For Eighth Floor

256

-

-

... More
For Nineth Floor

259

-

-

... More
For Tenth Floor

256

-

-

... More
For Eleventh Floor

256

-

-

... More
For Twelfth Floor

256

-

-

... More
For Terrace Floor and Above

175

-

-

... More
FORM WORK :

-

-

-

... More
Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc.complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid).

-

-

-

... More
Footing, Plinth Beam, etc.

4164

-

-

... More
Providing Form work and centering for reinforced cement concrete works including supports and strutting up to 3.30m height for plane surfaces as detailed below with all cross bracings using mild steel sheets of size 90cmx60cm and MS 10 gauge stiffened with welded mild steel angles of size 25mmx25mmx3mm for boarding laid over silver oak or country wood joists of size 10cmx6.5cm spaced at about 90cm centre to centre supported by caurina props 10cm to 13cm dia spaced at 75cm intervals and removing the same after a specified period without damaging the RCC works etc., complete complying with standard specifications and as directed by the PMC/Employer.

-

-

-

... More
For plane surfaces such as RCC floor slab, roof slab, beams, lintels, bed blocks, landing slab, waist slab, portico slabs and beams, etc.

64244

-

-

... More
For plane surfaces such as vertical slab, side slabs of boxing, vertical drops, facia, vertical wall, etc.

16674

-

-

... More
For plane surfaces such as rectangular or square RCC columns, sunshades, top and bottom slab of RCC boxing, etc.

18606

-

-

... More
Centering for curved surfaces of all RCC items of work

800

-

-

... More
Providing additional strutting to centering of RCC slabs of plain surface for every additional 1.0 metre height or part thereof but not less than 30 cm, over the initial 3.30 metre height from floor level using casurina props of 10cm to 13cm dia including cross bracing etc.,complete complying with standard specification and as directed by the PMC/Employer.

92170

-

-

... More
REINFORCEMENT STEEL :

-

-

-

... More
Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel grills for all RCC works as per design given including cost of steel and G.I. binding wire of 18G in all floors etc. complete complying with standard specification. (Contractor has to make his own arrangements for the supply of steel and binding wire)

3638

-

-

... More
Applying one coat of anticorrosive treatment on steel reinforcement rods (20 ltrs. Of anitcorrosive chemical for one mertic tonne of steel reinforcement rods) at site including a cost of required quantity of anticorrosive chemicals, (best approved quality) cement, consumables such as brushes, gloves and labour for anticorrosive coating etc. complete and as directed by the PMC/Employer. (The Quantity and brand of anticorrosive chemaical should be got approved by the PMC/Employer

1

-

-

... More
WATER PROOFING :

-

-

-

... More
Note: All the waterproofing treatment shall be executed through a specialized waterproofing agency authorised by the approved manufacturer and/or PMC/Employer. Contractor shall submit technical data sheet of each product, which shall use for execution.

-

-

-

... More
A written guarantee on non-judicial stamp paper shall be submitted by the main Contractor and his sub contractor who has carried out work for a minimum period of ten years from the certified date of completion for the satisfactory performance of the entire water-proofing system.

-

-

-

... More
water proofing works shall be executed under supervision of technical person of manufacturer. Contractor shall test all elements before and after water proofing treatment as directed by PMC/Employer. Rate shall include for testing process before and after waterproofing treatment. The rate includes giving 10 year warranty for waterproofing on a Rs.100/- stamp paper in approved proforma.

-

-

-

... More
NOTES: 1.Ponding test shall carried out on the mother slab 2. Rectification shall be carried out in case of leakages like crack treatment, grouting etc. to arrest the leakage. 3. Ponding test shall be carried out once again to check for leakages. 4. Once there are no leakages, waterproofing treatment shall be carried out, else the procedure shall be repeated. 5. Payment will be only once for the water proofing 6.The cost should include treatment of cove (wata) at the interface of floor and parapet /pedestals, sealing the annular space between the pipe and the masonry, making khurras, river sand screened and washed, at all leads, lifts, heights, scaffolding, with proper slope to drain-off water entirely, complete, etc.

-

-

-

... More
Terrace Waterproofing

-

-

-

... More
Finishing the top of Terrace floor with one course of solar reflective water proof, heat proof and cool roof ceramic tiles of size 300mmx300mmx8mm thick of approved quality laid in cement mortor 1:3 (one part of cement and three parts of sand) over base concrete mixed with calcium based mineral powder (60 kg for 1000 sqft) (before laying tiles, the tiles should be dipped with salin based nano liquid) and top Grouting with cement mortar 1:3 (one part of cement and three parts of sand) mixed with white cement, silicon powder and polimer additives (20kg m 1000 sqft.) and joint pointed with zycosil oil (200gm for 1000 sqft.) after grouting acrylic salin based liquid including cost of base concrete 1:2:4 mix using 6-10mm chips 40mm thick etc., complete complying with standard specifications including cost of all materials, labour charges for lifting to open terrace, laying and finishing and other incidental charges etc., complete and as directed by the PMC/Employers. (The Brand and quality of tiles should be got approved from the PMC/Employer before using).

4263

-

-

... More
Grading For Terrace Floor with 1:2:4: Plain Cement Concrete 1:2:4 (one cement, two crushed stone sand and four hard broken stone jelly) using 20mm jelly for wearing coat including laying, compacting, finishing and curing, etc., complete as per standard specificatins and as directed by the Project Officer.

425

-

-

... More
Terrace Water-proofing with Insulation

-

-

-

... More
Providing and applying waterproofing and insulation for terrace in two parts as per the specifications listed below and as approved by the PMC/Employer with a guarantee of 15 years: inclusive of chasing open the construction joints and sealing the same to form a U shaped groove of approx. 20mm width and 20mm depth, using polymer modified mortar carrying out injection grouting at the construction joints, honeycombs, etc, by injecting cement slurry grout admixed with expandable grout additive to full saturation wherever necessary thereafter. (ONLY PLAN AREA CONSIDERED FOR MEASUREMENTS)

-

-

-

... More
Polyurethane Based Waterproof coating system

10

-

-

... More
Providing and applying Liquid applied single component pitch free Polyurethane coating capable of bridging substrate cracks upto 2mm. System includes proper surface preparation to remove loose dust, dirt, loose mortar, curing compound etc., carry out cementitious injection grouting at leakage points and construction joints using cement slurry modified with Plasticised expandive grout admixture, application of polymer modified vatta at floor-wall junction, filling of annular space around rain water outlet Non-shrink cementitious grout application primer water dispersible epoxy primer @ 8- 10 SQM/ Litre and allow it to become tackfree and application of two coats of Polyurethane coating @ consumption of 2.2 kg/m2 in 2 coats to form DFT of 1.5mm (without priming / scratch coat conforming to ASTM C 898). complete including all tools and tackles as per manufacturer’s specification. Termination details - The coating shall be taken over the parapet well and shall be terminated by providing groove min 300mm down on the other side of the parapet wall Minimum Properties required for PU Membrane Elongation as per ASTM D 412 Tensile strength as per ASTM D 412) Puncture Resistance as per ASTM E 154 Water Head Resistance: as per BS-EN-12390-8 / DIN 1048) Adhesion to concrete: Bond Strength as per ASTM D 4541 Crack bridging capacity as per ASTM C 1305 Shore A Hardness as per ASTM D 2240): 75

-

-

-

... More
Non woven polyester Geo Textile fabric

10

-

-

... More
Providing and placing Non woven polyester Geo Textile fabric (minimum 300 gsm) having Grab Tensile Strength 650N ASTM D 4632, Puncture Strength (CBR) 1600 N ASTM D 6241, UV Resistance @ 150 hrs 85% (% Strength Retained) ASTM D 4355, with minimum 75mm overlap on the ends and sides as a separation layer on top of waterproofing

-

-

-

... More
PUF Insulation Spray

10

-

-

... More
Providing and applying Two Component Polyurethane based, HFC Blown, CFC & HCFC closed cell type sprayale rigid foam overdeck insulation system in average 40mm thickness. Surface prepartion includes cleaning of concrete surface to remove dust,dirt etc., followed by application of heated volumetric proportioning machine at 1:1 volumetric output fitted with spray gun, such as those manufactured by Graco or equivalent compressor enabled spray machine, followed by applying 2 coats of polyurea-polyurethane waterproofing cum sealer coat over PUF layer @ 1.5mm DFT. product shall be having properties viz. Gel time of 13 secs, Closed cell content 96 % as per ISO 4590, density of foam being 45 kg/m3 as per ASTM D 1622, Thermal Conductivity at 25 °C = 0.023 W/mK, Compressive strength Min 400 Kpa as per ASTM D-1621/94, Water absorption Min 3% as per EN12087, Fire resistance conforming to Class - B2 as per DIN 4102, Tensile Strength Min 500 Kpa as per ASTM D1623/78, Adhesion to substrate- 180 Kpa ASTM D4541,Water Vapour Transmission, EN12086-132 perms, Specific Gravity of Part A & Part B - 1.23 at 20°C etc, complete. All the honeycombed areas shall be identified and injected with cement slurry admixed with AM. Check for moisture, it shall be below 5%, etc, complete. Thickness may varies as per site and client requirement as per U Value. (Primer Coat)

-

-

-

... More
Non woven polyester Geo Textile fabric

10

-

-

... More
WET AREA WATER PROOFING

-

-

-

... More
Providing Polymer Coating (Water Proof Coating) for sunken portion of wet areas with following specification and the surface shall be cleaned to remove all dust, foregin, matters lose materials or any other deposits of contamination by rubbing with wire brush. Slurry: Dry blend and polymer liquid blend shall be mixed into the desired ratio as per recommendation of the supplier. The mix shall be stirred thoroughly until no bubbles remain in the mix. Any lumps found in mix shall be removed. Apply first coat of polymer modified cementitious slurry by brush on wet cleaned surface. After drying, second coat shall be applied on the first coat as directed by the PMC/Employer etc. The rate inclusive of cost of materials and labour, etc., complete.

2541

-

-

... More
Light weight Sunken filling using broken brick jelly 20 mm gauge The proportion of broken brick jelly of ratio being 1:3:6 (1part cement,3 part fine aggregate & 6 part broken brick jelly), well beaten by wooden beaters for giving required slope and thickness required etc complete complying with standard specifications and as directed by PMC/Employer.

366

-

-

... More
UGT/OHT (inside) waterproofing with Anti microbial Coating

-

-

-

... More
Waterproofing: Providing and Applying CFTRI approved two component flexible polymer modified acrylic cementitious waterproofing coating with a mix ratio of (5 Liquid :7 Powder) to the RCC surface of the UGT/OHT tank applied @ 2.2kg/m2 in 2 coats to achieve 1.2mm DFT, having Elongation at break 120% as per ASTM D 412, Tensile strength 1N/ mm2 as per ASTM D 412, Adhesion strength: 0.80N/mm2 as per ASTM D 4541, crack bridging upto 2mm as per ASTM C 836. The finished cost to include surface preparation, making coving of 50 mm X 50mm at all right angles of wall Junction with Polymer Repair Mortar and lay 45 gsm glass fibre mesh over the angle fillet when the first coat in still wet, treatment of cracks completely as per specification. Followed by applying 15 mm thick dimensionally stable fibrous reinforced cementitious structural grade dual shrinkage Polymer Mortar on as protective plastering @ 29kg/m2. The material having Compressive strength of 38 MPa at 28 days as per EN 12190, Adhesive Bond Test, 1.5 Mpa as per EN 1542, followed by Water curing by sprinkling water for 3 times a day for 5- 7 days. Followed by applying two B139component, water-based food grade epoxy resin coating on inside surface of Potable water tank having anti algae, antifungal, Non-toxic, hygiene cum damp-proof coating Certified by CFTRI as per 21 CFR 175 – 300 of US – FDA, having mixing Ratio (Base: Hardener: Water) – 1:1:1 to be applied @ 0.35 Kg/m2 in 2 coats. Ensure that this coating is applied over the protective plaster. The Waterproofing material shall have Specific Gravity: 1.2, Water vapor permeance: 244.48 g/m2/24 hrs, as per IS 7809/Pt 2/1977, Adhesion strength: 2 N/mm2 as per ASTM D 4541: 02. The finished cost to include surface preparation completely as per specification

2506

-

-

... More
Retaining wall/ UG tank wall (outside) Waterproofing with SBS Membrane

-

-

-

... More
Providing and laying water proofing treatment to the Retaining wall, water retaining structures outside with fully bonded 1.6mm Thick SBS modified self-adhesive, cross laminated HDPE lining waterproofing membrane, conforming to IS 16471:2017 Type A, requirements of UG waterproofing structures, The SBS membrane shall have Mass per Unit Area 1.8 Kg/m2 as per ASTM D 5147, Puncture resistance 200 N as per ASTM E 154, Elongation 180% as per ASTM D 412-06, Tensile Strength 4 Mpa as per ASTM D 412- 06, Tear resistance 20 N/mm as per ASTM D 4073, Hydrostatic pressure 50M as per DIN 1048. The lap with HDPE membrane shall be 100mm treated with TS tape. followed by the installation of 8-10mm THK polyethylene dimpled drain board having compressive strength 400kN/m2 (as per ISO 25619-2). The finished cost includes surface preparation, making coving and a coat of solvent based bituminous primer @ 0.25l/m2 on entire surface before laying membrane completely as per specification.

663

-

-

... More
Underground structures waterproofing with HDPE membrane

-

-

-

... More
Providing and laying water proofing treatment below UG tank raft over PCC, Lift pits, with fully bonded 1.5 mm thick HDPE waterproofing pressure sensitive adhesive membrane over PCC before laying raft concrete having higher puncture resistance of 1000N as per ASTM E 154, confirming to BS 8102 & IS 16471:2017, requirements of UG waterproofing structures. Laying adjacent sheets by keeping overlap of 75mm, end overlaps to be treated using double sided tape. The membrane shall have Tensile strength 25 Mpa as per ASTM D 412, Elongation 500% as per ASTM D 412, Hydrostatic head resistance 70m head of water as per ASTM D 5385, Low Temperature Flexibility: -25 deg C, Peel Adhesion to Concrete 880 N/m as per ASTM D 903 Modified, UV Exposure 45 Days. The finished cost including surface preparation completely as per specification.

1466

-

-

... More
Newly Constructed Roof/balcony/Refugee area with Cementatius Waterproof coating below 500 Sq.m

-

-

-

... More
Providing and Applying CFTRI approved two component flexible polymer modified acrylic cementitious waterproofing coating with a mix ratio of (5 Liquid :7 Powder) to the RCC surface like Roof, bathroom, toilet, balcony & utility area applied @ 2.2kg/m2 in 2 coats to achieve 1.2mm DFT, having Elongation at break 120% as per ASTM D 412, Tensile strength 1N/ mm2 as per ASTM D 412, Adhesion strength: 0.80N/mm2 as per ASTM D 4541, crack bridging upto 2mm as per ASTM C 836. The finished cost to include surface preparation, making coving of 50 mm X 50mm at all right angles of wall Junction with Polymer Repair Mortar and lay 45 gsm glass fibre mesh over the angle fillet when the first coat in still wet, treatment of cracks completely as per specification.

1104

-

-

... More
Providing and fixing heat resistance terrace tiles(300mmx300mmx20mm)with SRI (Solar refractive index)78,solar refelction 0.70 and initial emitance 0.75 on waterproof and slopped surface of terrace, laid on 20mm thick cement, sand, mortar in ratio of 1:4(1 Cement : 4 course sand) and grouting joints with mix of white cement and marble powder in ratio of 1:1,including rubbing and polishing of surface upto 3 cuts complete,including providing skirting upto 150mm height along parapet wall in the same manner.

1126

-

-

... More
STRUCTURAL STEEL WORKS

-

-

-

... More
Note for items of this Section : Contractor shall prepare shop drawing based on intent/ concept drawing and submit the same to PMC/Employer for approval and shall get approval before mock up/ execution of work. Work shall be carried out as per final approved shop drawing and approved mock up. Contractor shall responsible against stability, safety, leakage, etc all complete. Testing work shall be carried out by the Contractor as suggested by PMC/Employer.

-

-

-

... More
Supply, Fabrication, Erection, alignment and levels as per approved shop drawing of structural steel work in built up sections comprising of ISMB, ISMC, angle, plates and round bar section etc., for column, truss,MS Door in Gas Bank, Stream Generator Room. Necessary permanent rivets, bolts, washers and nuts, handling, straightening, cutting, drilling holes, welding, shop assembly, transport to erection site, storing, leading to erection site and apply one coat of anti corrosive yellow primer paint and 2 coat of approved colour paint of approved make prior to erection. (payment to be made on the basis of standard section weights for net weight erected in position excluding permanent/temporary bolts, rivets etc., Rate should include the cost of permanent bolts, nuts, and washers packing plates as required and approved. And no seperate measurement shall be taken for payment of permanent bolts, nuts, all types of washers and packing plates etc..)

23291

-

-

... More
Supplying, cutting to shape, securing to the supporting members with bolts or welding as shown on drawings, 6mm thk M.S. Chequered plate . The rate shall be for the actually placed plate.

4782

-

-

... More
Providing, fabricating and fixing M.S. grills work for windows, gates, ladders, rail pipes, nosing angles, with M.S.lugs in staircase steps etc., made out of M.S rods, flats, angles, pipes, channels etc. including necessary fixtures complete as per drawings and specifications and as directed by thePMC/Employer

5250

-

-

... More
MISCELLANEOUS WORK

-

-

-

... More
Providing and Placing in position suitable PVC water stops conforming to IS:12200 for construction/expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete

949

-

-

... More
Providing expansion joint in RCC floor slab for 12.5mm width using polysulphide as sealent on the top and bottom for a depth of 7.5mm Eachand packing the inner space using compressible non-absorbent filler materials including cost of labour for cutting and fixing filler materials and laying polysulphide sealent with necessary spatula etc., complete complying with standard specifications and as directed

12

-

-

... More
Supplying and grouting of pockets inside the concrete structures using non shrink compensated cementitious grout including making arrangements to fix the MS framework , MS bolts , inserts, etc to required line ,level and position & cleaning the pockets & surface using water to make it free from dirt and dust ,pouring the ready mixed grout in the locations as per manufacturers detail specifications including curing at all levels and locations etc., complete all as directed

2

-

-

... More
Cutting, bending and placing in position reinforcement bars of required diameter and confirming to IS 1786 wherever required by means of welding and anchorage in the wall/beams with approved Chemical bonding compound lockset after proper drilling holes in walls/beams by machine drill as per requirements with existing reinforcement.

-

-

-

4

-

-

4

-

-

4

-

-

5

-

-

4

-

-

... More
Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of PMC/Employer

-

-

-

... More
Made of G.I. wire of dia 4 mm

509

-

-

... More
Providing corrugated galvalume sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.5mm thick

147

-

-

... More
Manufacturing, supplying and fixing Precast Reinforced Cement Concrete slabs of following thickness in RCC 1:2:4 (one cement, two crushed stone sand and four aggregates), using following HBGS jelly excluding cost of reinforcement steel in position but including cost of moulding charges, casting of slab, finishing, curing and fixing in position in all floors etc., complete complying with standard specification and as directed.

-

-

-

... More
75mm thick

20

-

-

... More
100mm Thick

20

-

-

... More
150mm Thick

11

-

-

... More
200mm Thick

12

-

-

... More
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of PMC/Employer.

-

-

-

... More
200mm Dia

8

-

-

... More
Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, reinforced with 8 mm dia four Nos longitudinal & 9 Nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of PMC/Employer.

-

-

-

... More
75mm thick

379

-

-

... More
100mm Thick

8

-

-

... More
150mm Thick

8

-

-

... More
Providing and fixing of Precast Concrete U Drain of Grade - M25 conforming to relevant I. S. and CPHEEO Specification ( including nominal reinforcement if required as per design consideration) the cost including with necessary earth work excavation, backfilling and compaction etc, complete.

-

-

-

... More
400mm width

1

-

-

... More
500mm width

1

-

-

... More
Providing and placing in position precast reinforced cement concrete Manhole square / rectanglur type with wall thickness of 200mm as per drawing and incluing 100mm thick thick PCC 1:2:4 bottom raft with 50mm offset beyond raft on periphery. Supplying and fixing heavy duty FRP manhole cover and frame (Heavy duty HHD-20grade designation) as per IS 12592 (Part I and II) complete in all respect and the quoted rate is includng making necessary holes of required sizes for carrying through service lines etc., providing steel hooks for lifting etc, form work in precasting, handling, hoisting, centering and erection complete for all levels , including the cost of reinforcement

-

-

-

... More
Size-500x500x600mm

1

-

-

... More
Hole Packing treatment on service line Providing and applying total packing treatment on any type of pipes comes into water proofing area as follows: Preparing the inside surface of core and Pipe by roughening using suitable Sand paper to get better adhesion prior to packing works. Cleaning the surface by wire brushing followed water jet to remove any laitance or loose flaky particles. Applying a coat of polymer coating using Polymer bonding agent to enhance adhesion between the packing material and other surfaces.

2

-

-

... More
Packing the gap using non shrink cement polymer based grout using Non-shrink cementitious grout upto the surface of the bore whilst the bonding agent is in tacky state before application of water proofing treatment. For the purpose of payment, the area obtained by perimeter of outer dia of pipe multiplied by the depth of treatment along the pipe shall be measured in sqm. Treatment shall be executed by same agency with same manufacturer's product. Warranty includes in water proofing item.

-

-

-

... More
Providing laying and fixing of following dia RCC Hume Pipe NP2 Class - IS 458/2003 in ground complete with RCC Collers, jointing with cement mortar 1:2 as PMC/Employer.

-

-

-

... More
200mm Dia RCC hume pipe

50

-

-

... More
ARCHITECTURAL & FINISHES WORKS

-

-

-

... More
Masonry works

-

-

-

... More
Note : 1. "Procurement of items with astehetic value and visibility shall be on prior approval of Architect and PMC/Employer for specific arae of application."

-

-

-

... More
Masonry work using Autoclaved Aerated cement blocks of size 600 x 200x 200 mm in Self curing AAC in cement Motar (1:6) (one of cement and six of M Sand) along the boundaries using AAC Block 600x 200x 200mm)minimum average crushing strength of 50Kg/sqcm in all floors including labour for fixing the doors , windows and ventilator frames in position fixing of hold fast , scaffolding ,curing etc complete in all respects complying with relevant standard specifications and drawings and as directed by the PMC/Employer. ( AAC Block should get approved by the PMC/Employer before execution of work)

-

-

-

... More
Basement 01

1

-

-

... More
In Ground, Mezanine floor & External

906

-

-

... More
For First floor

268

-

-

... More
For second floor

257

-

-

... More
For third Floor

280

-

-

... More
For fourth Floor

280

-

-

... More
For Fifth Floor

281

-

-

... More
For Sixth Floor

287

-

-

... More
For Seventh Floor

280

-

-

... More
For Eighth Floor

304

-

-

... More
For Nineth Floor

225

-

-

... More
For Tenth Floor

304

-

-

... More
For Eleventh Floor

206

-

-

... More
For Twelfth Floor

204

-

-

... More
For Terrace Floor

205

-

-

... More
Masonry work using Autoclaved Aerated cement blocks of size 600 x 200x150 mm in Self curing AAC in cement Motar (1:6) (one of cement and six of M Sand) along the boundaries using AAC Block 600x 200x 200mm)minimum average crushing strength of 50Kg/sqcm in all floors including labour for fixing the doors , windows and ventilator frames in position fixing of hold fast , scaffolding ,curing etc complete in all respects complying with relevant standard specifications and drawings and as directed by the PMC/Employer. ( AAC Block should get approved by the PMC/Employer before execution of work)

-

-

-

... More
Basement 01

1

-

-

... More
In Ground floor & External

9

-

-

... More
For First floor

3

-

-

... More
For second floor

3

-

-

... More
For third Floor

9

-

-

... More
For fourth Floor

8

-

-

... More
For Fifth Floor

9

-

-

... More
For Sixth Floor

8

-

-

... More
For Seventh Floor

8

-

-

... More
For Eighth Floor

8

-

-

... More
For Nineth Floor

9

-

-

... More
For Tenth Floor

8

-

-

... More
For Eleventh Floor

8

-

-

... More
For Twelfth Floor

8

-

-

... More
For Terrace Floor

5

-

-

... More
Solid Concrete blocks:Providing and constructing 200mm thick solid cement concrete block masonry work at all levels in cement mortar 1:4 using standard size of 400mm x 200mm of solid cement concrete blocks, with minimum compressive strength of 3 N/Sq mm confirming to IS 2185 or equivalent BS, all scaffolding, staging, curing, and including chicken mesh, etc all complete as per standard specification.

-

-

-

... More
Basement 01

1

-

-

... More
In Ground floor & External

319

-

-

... More
For First floor

54

-

-

... More
For second floor

64

-

-

... More
For third Floor

105

-

-

... More
For fourth Floor

105

-

-

... More
For Fifth Floor

105

-

-

... More
For Sixth Floor

105

-

-

... More
For Seventh Floor

105

-

-

... More
For Eighth Floor

105

-

-

... More
For Nineth Floor

105

-

-

... More
For Tenth Floor

105

-

-

... More
For Eleventh Floor

105

-

-

... More
For Twelfth Floor

105

-

-

... More
For Terrace Floor

1

-

-

... More
Solid Concrete blocks:Providing and constructing 150mm thick solid cement concrete block masonry work at all levels in cement mortar 1:4 using standard size of 400mm x 200mm of solid cement concrete blocks, with minimum compressive strength of 3 N/Sq mm confirming to IS 2185 or equivalent BS, all scaffolding, staging, curing, and including chicken mesh, etc all complete as per standard specification.

-

-

-

... More
Basement 01

1

-

-

... More
In Ground floor & External

30

-

-

... More
For First floor

32

-

-

... More
For second floor

31

-

-

... More
For third Floor

69

-

-

... More
For fourth Floor

69

-

-

... More
For Fifth Floor

69

-

-

... More
For Sixth Floor

69

-

-

... More
For Seventh Floor

69

-

-

... More
For Eighth Floor

69

-

-

... More
For Nineth Floor

69

-

-

... More
For Tenth Floor

69

-

-

... More
For Eleventh Floor

59

-

-

... More
For Twelfth Floor

69

-

-

... More
For Terrace Floor

1

-

-

... More
Wall Preparation

-

-

-

... More
Plastering with Cement Mortar 1:5 (One cement and Five sand), 12mm thick conforming to BIS at 2% by weight of cement used including finsihing, curing, etc., in all floors including necesary band, drip moulds, curing etc., complete complying with standard specification and as directed by the PMC/Employer.

16875

-

-

... More
Plastering with Cement Mortar 1:5 (One cement and Five sand), 12mm thick mixed with water proofing compound conforming to BIS at 2% by weight of cement used including finsihing, curing, etc., in all floors including necesary band, drip moulds, curing etc., complete complying with standard specification and as directed by the PMC/Employer.

13633

-

-

... More
Plastering with Cement Mortar 1:5 (One Cement and Three Plastering Sand) 20mm thick mixed with water proofing compound conforming to BIS at 2% by weight of cement used including finsihing, curing, etc., complete in all floors complying with standard specification and as directed by the Engineer Cost to include Drip course / Groove as specified by designer )

12331

-

-

... More
Providing and applying 12 mm thick ( average ) premixed formulated one coat gypsum lightweight plaster having additives and light weight aggregates as vermiculite / perlite respectively conforming to IS:2547 ( Part -1 & II ) 1976, applied on hacked/ uneven background such as bare brick/ block/ RCC work on wall & ceiling at all floors and locations, finished in smooth line and level etc. complete.

-

-

-

... More
for building

35018

-

-

... More
Providing and applying Bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of PMC/Employer complete in all respect. SBR Polymer ( @10% of cement weight ) modified cementitious bond coat @2.2kg cement per sqm of surface area mixed with specified proportion of approved polymer.

-

-

-

... More
for building

6499

-

-

... More
for staircase area

1021

-

-

... More
for External area

69

-

-

... More
Providing and laying Plain Cement Concrete minimum 40mm thick with 1:2:4 (one cement, two m sand and four hard broken stone jelly) using 20mm jelly for wearing coat including laying, compacting, finishing and curing, etc., complete as per standard specificatins and as directed by the PMC/Employer. ( Additional PCC below flooring )

613

-

-

... More
Flooring & Dado & Skirting

-

-

-

... More
Note: Contractor shall submit flooring mockup as per the drawings and get approved by PMC/Employer before execution of work.

-

-

-

... More
Paving the floor with best quality Anti skid Vitrified Tiles Flooring of size 600 x 600 x 10mm of approved colour, shade and quality laid in cement mortar 1:3 (one cement and three sand) 20mm thick in all floors and the top pointed with the white cement mixed same colour pigments etc., complete complying with standard specification. (The make and brand of the tiles should be got approved by PMC/Employer before use on works)

593

-

-

... More
Providing and Cladding on walls in proper line, level and alignment, Stain Free Nano Polish Vitrified Tiles 600x600x8mm Cost to be inclusive of cleaning on surface, etc complete as per directions. with backing coat of cement mortar 1:3 (1 cement : 3 fine sand), not exceeding 12mm thick, with neat cement slurry paste, pointing with matching cement paste with pigmented additives to match the shade of the tile.

319

-

-

... More
100mm thick Anti Skid Vitrified Skirting

134

-

-

... More
Providing and Filling the tile joint with epoxy grout with following specification: Surface preparation including cleaning the joint to be free from dust and loose particles. Providing masking tape on either side of the tile joint edges and providing sealing the tile gap with epoxy tile joint grout and finishing neatly and as directed by the PMC/Employer. The rate inclusive of cost of materials and labour, etc. complete.

767

-

-

... More
Paving the floor with best approved quality fine polished Kota stone slabs of size 600 x 600 of 18 / 20mm with machine cut edges and matching marble slab not less than 100mm width other than Adanga Marbles as border laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three crushed stone sand) fixing the slabs in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments and polishing with floor polisher to a high degree of finish etc., The kota stone slabs and other materials to be used shall be got approved by the PMC/Employer concerned before use on work, etc., complete as per standard speicification.

-

-

-

... More
Service areas flooring

5706

-

-

... More
Staircase Treads 300mm wide

135

-

-

... More
Staircase Landing, Midlanding Area

185

-

-

... More
Guard room Kota flooring

253

-

-

... More
Staircase Treads 300mm wide

7

-

-

... More
Staircase Landing, Midlanding Area

1

-

-

... More
Extra for pre finished nosing in tread of stpes of kota stone / Sand stone slab

450

-

-

... More
Paving the floor with best approved quality fine polished Kota stone slabs of size 600 x 600 of 18 / 20mm with machine cut edges and matching marble slab not less than 100mm width other than Adanga Marbles as border laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three crushed stone sand) fixing the slabs in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments and polishing with floor polisher to a high degree of finish etc., The kota stone slabs and other materials to be used shall be got approved by the PMC/Employer concerned before use on work, etc., complete as per standard speicification.

-

-

-

... More
Service areas Skirting of 100mm high

303

-

-

... More
Staircase Risers 150mm high

68

-

-

... More
Staircase Skirting of 100mm high

22

-

-

... More
Guard room Kota Skirting of 100mm high

150

-

-

... More
Staircase Risers 150mm high

4

-

-

... More
Staircase Skirting of 100mm high

2

-

-

... More
Providing and fixing 18mm thick gang saw cut, mirror polished, premoulded and prepolished machine cut for kitchen platforms, vanity counter, window sills, facias ans similar locations for required size, approved shade, colour and texure laid over 20mm thick base cement mortar 1:4 ( 1 Cement : 4 coarse sand), joints treated with white cement , mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high glass finish etc. complete at all levels.

-

-

-

... More
Granite Lift Jamb

46

-

-

... More
Providing and fixing removable raised / false access flrooing with system and its components of approved make for different plenum height with possible height adjustement upto 50mm, comprising of modular laoad bearing floor panel supported on G.i. rectangular stinger frame work and G.i. pedestal etc, all complete, as per the architectrual drawing as specified ad as directed by engineer- in -charge consisting of: (a) providing at required spacing to form modular framework, pedestals made out of FI tubes of theicnss inimum 2mm and 25mm outer diametr, fully welded on to the G.I. base plate of size 100mm x 100mm x 3mm at the bottom of the pedestal tube, G.I. pedestal head of size 75mm x 75mm x 3.5mm welded with GI fully threaded stud 16mm outer diameter with tow GI check nuts screwed on the stud for level adjustement up to 50mm, locking and stabilzing the pedestal head in position at the required level. The pedestals shall be fixed to the subfloor ( base ) throuh base plate using epoxy based adhesive of approved make or the machine screw ith rawl plug. (b) Stringers system in all steel construction hot dipped galvanized of rectangular size 570x20x30x0.80 mm thick having holes at both ends for securing the stringers on to the pedestal head using fully threaded screws ensuring maximum lateral stability in all directions, the grid formed by the pedstal and stringer assembly shall receive the floor paenl, this system shall provide adequate solid, rigid support for access floor panel, the system shall provide a minimum clear uniterrupted clearance between the bottom of the floor for electrical conduits and wiring etc all complete as pe the architectural drawings, as specified adn as directed by the PMC/Employer (c) Providing and fixing Access floor panel of 600x600x32 mm mdium grade filled steel anti static high pressure lamination of 800H grade ( FS800H). Access floor panel shall be steel welded construction with an enclosed bottom pan with uniform pattern of 64 hemispherical cones. The top and bootm plates of steel gauges:top 0.6 mm and bottom 9.7 mm fused spot welded tohether ( minimum 64 welds in each dome and 20 welds along each flange).

-

-

-

... More
The panel should be corrresist epoxy coated for lifetime rust protection and cavity formed by the top and bottom plate is filled with pyrogrip noncomustible portland cementitious core mixed wih light weight foaming compound. The access floor shall be factory finished with anti-static high pressure laminate with non warp technology up to 1mm thickness for superior adhesion and surface flatness within 0.75mm. The panel is to withstand a concentrated load of 363kgs appled on area 25mm x 25mm without collapse in the centre of the panel which is placed on four steel blocks. The panel will withstand and uniformly distrubute load (UDL) minimum 1259 kg/sqm and an impact load fof 50kg all complte as per the approved manufacturers specification and as per the direction of PMC/Employer All specifications must be printed on the side of the panel to ensure the quality of the product.

-

-

-

... More
300mm finished floor height (FFH)

1

-

-

... More
Providing Granolithic Floor finish of the 40mm thickness with plain cement concrete 1:2:4 ( one cement, 2 Crushed Stone sand and four aggregate ) using 10 to 12 mm Gauage hard broken stone jelly including laying, finishing and the top rubbed smooth with power trawl, thread lining, curing etc complete complying with standard specification and as directed by the PMC/Employer. ( the rate is inclusive of necessary planking for panelling wherever necessary and as directed by the PMC/Employer )

28390

-

-

... More
Counters

-

-

-

... More
Providing and fixing 18mm thick gang saw cut, mirror polished, premoulded and prepolished machine cut for kitchen platforms, vanity counter, window sills, facias ans similar locations for required size, approved shade, colour and texure laid over 20mm thick base cement mortar 1:4 ( 1 Cement : 4 coarse sand), joints treated with white cement , mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high glass finish etc. complete at all levels. ( rcc base for counter is to be provided )

6

-

-

... More
Extra for fixing Marble/ Granite stone, over and above corresponding basic item, in facia and drops of width upto 150mm with epoxy resin based adhesive, including cleaning etc, complete.

10

-

-

... More
Extra for providing opening of required size & shape for wash basin / kitchen sink in kitchen platform, vanity counter and similar location in marble / granite / stone work, inclduing necessary holes for pillar taps, etc incldung moulding, rubbing and polishing of cut edges, etc complete.

6

-

-

... More
Painting

-

-

-

... More
Finishing walls with waterproofing cement paint of required shasde : new work ( tow or more coats applied @3.84 kg/ 10 Sqm)

-

-

-

... More
On wall, Columns,etc for core & service area

10697

-

-

... More
on wall for Staircase area

3455

-

-

... More
On True Slab Ceiling Area

5841

-

-

... More
on True Slab Ceiling for staircase area

1995

-

-

... More
for staff toilet Ceiling area

47

-

-

... More
Wall painting with two coats premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including one oat of primer wherever required to achieve even shade and colour.( rate shall be inclued for all floors )

-

-

-

... More
On wall, Columns,etc - External

260

-

-

... More
On True Slab - External

241

-

-

... More
Supplying and painting the walls with two coats of wall putty as instructed by the PMC/Employer including preparation of surface curing, etc., complete in all floors complying with standard specifications (The wall putty shall be got approved by the PMC/Employer before use of work).

22489

-

-

... More
White washing one coat with freshly burnt white shell lime in all floors including cost of lime, blue powder, fevicol type gum, brushes, scaffolding charges, etc., complete complying with standard specification and as directed by the PMC/Employer.

20561

-

-

... More
Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the PMC/Employer before use on works.)

214

-

-

... More
Finishing walls with textured exterior paint of required shade: New work( two or more coats applied @ 3.28 ltr / 10 sqm ) over and including priming coat of exterior primer applied @ 2.20 kg / 10 sqm

5497

-

-

... More
Doors

-

-

-

... More
2Hr Insulated Metal Fire Rated Doors with Frame Supply and Installation of Medium Duty Hollow Metal Fire Door at all levels of approved manufacturer, Single / Double leaf, as per IS 3614: 2021, for 120 min integrity & 30 min. insulation. Pressed galvanized steel confirming to IS 277 with the following specification. Recommended fire door shall be tested as per IS/ISO 3008-1 & IS/ ISO 834-1, from Exova/TBW/CBRI approved lab. Labled fire doors shall be with fire rated hardware and vision panel all as a complete assembly. Proper label confirming the type of door and the hourly rating is mandatory. Test Cetificates to be submited along with the shop drgs for approvals. Door frame shall be Double rebate grooved profile of size 125 x 55mm or 143mm x 57mm made out of 1.20mm (18 gauge) or 1.60mm (16 gauge) minimum thick galvanized steel sheet. Frames shall be mitered and field assembled with self tabs. Frames to have inbuild grooved sealing system for taking fire rated seals. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Frames should be provided with back plate bracket and anchor fasteners of HILTI / equivalent make 3 Nos of anchor fastners 10mm x 160mm with split end on either side and 2 Nos on top for installation on a finished plastered masonry wall opening. Frames shall be filled with fire rated puff. Steel door shutter shall be 60mm / 50mm / 45mm thick fully flush double skin step design door, insulated with or without vision lite. Door leaf shall be manufactured from 1.2mm (18 guage) or 1.0mm thick galvanised steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. The infill material shall be 120kg high density rockwool insulation material. Intumescent seals 15 x 1.5mm to be provided. All doors shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending radius of 1.4mm. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf.

-

-

-

... More
Door and frames shall be finished Pure Polyster Powder coated and shall have passed minimum 500 hours of salt sprey test. Rate shall include for supply and fix 3mm thick base plates, all joints of frames with provision for anchor bolt fixing to wall / RC surface, reinforcement pad for fixing of door closers, factory finish, pre-punched cut outs to receive hardwares and iron Mongery, 3mm thick hinge plates predrilled to receive hinges for screw mounted fixing, stainless steel CE marked ball bearing hinges, handles, locks, door closer, panic bar, concealled drop down seal, flush bolt, intumisent seal to shutter etc all complete of approved make & as per detail drgs. Rate shall also include for grouting the frame with PU foam between wall and frame to the required thickness as per manufacturer’s specifications. Rate to inclusive of factory fitted all required SS hardwares but supply of all required SS hardwares shall be paid separately. Rate to include factory fitted vision panels wherever required, concealled drop down seal & intumisent seal to shutter and frame of approved make as per manufactures specfications.

-

-

-

... More
FD1 (Double LeaF-Openable Door) with metal Door shutter with vision panel of size 150mm x 750mm Size: 1800mm x 2400mm

109

-

-

... More
2Hr Unisulated Metal Fire Rated Doors with Frame Providing and fixing of Medium Duty Hollow metal fire door at all levels approved Manufacturer, Single / Double leaf, as per IS 3614: 2021, for 120 min integrity. Pressed galvanized steel confirming to IS 277 with the following specification. Recommended fire door shall be tested as per IS/ISO 3008-1 & IS/ ISO 834-1, from Exova/TBW/CBRI approved lab. Labled fire doors shall be with fire rated hardware and vision panel all as a complete assembly. Proper label confirming the type of door and the hourly rating is mandatory. Test Cetificates to be submited along with the shop drgs for approvals. Door frame shall be single rebate grooved profile of size 125 x 55mm / 143mm x 57mm / 100mm x 57mm made out of 1.20mm (18 gauge) or 1.00mm (20 gauge) minimum thick galvanized steel sheet. Frames shall be mitered and field assembled with self tabs. Frames to have inbuild grooved sealing system for taking fire rated seals. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Frames should be provided with back plate bracket and anchor fasteners of HILTI / equivalent make 3 Nos of anchor fastners 10mm x 160mm with split end on either side and 2 Nos on top for installation on a finished plastered masonry wall opening. Frames shall be filled with fire rated puff. Steel door shutter shall be 46mm / 50mm thick fully flush double skin step design door, unsulated. Door leaf shall be manufactured from 1.2mm (18 guage) or 1.6mm (16 guage) thick galvanised steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. The infill material shall be honeycomb core. All doors shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending radius of 1.4mm. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf.

-

-

-

... More
Door and frames shall be finished Pure Polyster Powder coated and shall have passed minimum 500 hours of salt sprey test. Rate shall include for supply and fix 3mm thick base plates, all joints of frames with provision for anchor bolt fixing to wall / RC surface, reinforcement pad for fixing of door closers, factory finish, pre-punched cut outs to receive hardwares and iron Mongery, 3mm thick hinge plates predrilled to receive hinges for screw mounted fixing, stainless steel CE marked ball bearing hinges, handles, locks, door closer, panic bar, concealled drop down seal, flush bolt, intumisent seal to shutter etc all complete of approved make Rate shall also include for grouting the frame with cement slurry between wall and frame to the required thickness as per manufacturer’s specifications. Rate to inclusive of factory fitted all required SS hardwares but supply of all required SS hardwares shall be paid separately. Rate to include factory fitted concealled drop down seal & intumisent seal to shutter and frame of approved make as per manufactures specfications.

-

-

-

... More
FD3 (Double Leaf-Openable Door) with metal Door shutter with vision panel of size 150mmx 750mm Size: 1200mm & 300m x 2400mm

47

-

-

... More
FD4 (Single Leaf -Openable Door) with metal Door shutter with vision panel of size 150mmx 750mm Size: 1200mm x 2400mm

39

-

-

... More
FD5 (Double Leaf-Openable Door) with metal Door shutter with vision panel of size 150mmx 750mm Size: 1800mm x 2400mm

2

-

-

... More
FD6 (Single Leaf-Openable Door) with metal Door shutter with vision panel of size 150mmx 750mm Size: 1200mm x 2400mm

3

-

-

... More
FD2 (Double Leaf-Openable Door) with shutter in combination of Metal frame & fire rated glass vision panel Size: 2000mm x 2400mm

84

-

-

... More
2Hr Uninsulated Metal Fire Rated Doors with single rebate Door Frame Supply and Installation of Medium Duty Hollow Metal Fire Door at all levels of approved manufacturer, Single / Double leaf, as per IS 3614: 2021, for 120 min integrity. Pressed galvanized steel confirming to IS 277 with the following specification. Recommended fire door shall be tested as per IS/ISO 3008-1 & IS/ ISO 834-1, from Exova/TBW/CBRI approved lab. Labled fire doors shall be with fire rated hardware and vision panel all as a complete assembly. Proper label confirming the type of door and the hourly rating is mandatory. Test Cetificates to be submited along with the shop drgs for approvals. Door frame shall be single rebate grooved profile of size 125 x 55mm / 143mm x 57mm / 100mm x 57mm made out of 1.20mm (18 gauge) or 1.00mm (20 gauge) minimum thick galvanized steel sheet. Frames shall be mitered and field assembled with self tabs. Frames to have inbuild grooved sealing system for taking fire rated seals. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Frames should be provided with back plate bracket and anchor fasteners of HILTI / equivalent make 3 Nos of anchor fastners 10mm x 160mm with split end on either side and 2 Nos on top for installation on a finished plastered masonry wall opening. Frames shall be filled with fire rated puff. Steel door shutter shall be 46mm / 50mm thick fully flush double skin step design door, unsulated. Door leaf shall be manufactured from 1.2mm (18 guage) or 1.6mm (16 guage) thick galvanised steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. The infill material shall be honeycomb core. All doors shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending radius of 1.4mm. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf.

-

-

-

... More
Door and frames shall be finished Pure Polyster Powder coated and shall have passed minimum 500 hours of salt sprey test. Rate shall include for supply and fix 3mm thick base plates, all joints of frames with provision for anchor bolt fixing to wall / RC surface, reinforcement pad for fixing of door closers, factory finish, pre-punched cut outs to receive hardwares and iron Mongery, 3mm thick hinge plates predrilled to receive hinges for screw mounted fixing, stainless steel CE marked ball bearing hinges, handles, locks, flush bolt, intumisent seal to shutter etc. all complete of approved make & as per detail drgs. Rate shall also include for grouting the frame with PU foam between wall and frame to the required thickness as per manufacturer’s specifications. Rate to inclusive of factory fitted all required SS hardwares but supply of all required SS hardwares shall be paid separately. Rate to include factory fitted intumisent seal to shutter and frame of approved make as per manufactures specfications.

-

-

-

... More
SD2 (Single Leaf-Openable Door) Size: 900mm x 2100mm

329

-

-

... More
SD3 (Single Leaf-Openable Door) Size: 600mm x 2100mm

2

-

-

... More
Flush Door Shutters with CNC router cut Louvers at Bottom Providing and fixing ISI marked Flush Door shutters conforming to IS : 2202 (part I) of approved make 45mm thick, doors shall be factory finished and finishing of shutters with 1mm thick Laminate from both sides. Rate to be inclusive of providing lipping with 2nd class teak wood battens 6mm minimum depth on all edges of flush door shutters and finished in matching PU polish as directed. All required SS Hardwares to be paid separately. Rate to be inclusive of 1) factory finished CNC Router cut Louvers and finished as per detail drgs at bottom part of shutters and size as per detail drgs . 2) concealled drop down seal of approved make. Finished with 1mm thick Laminate from both sides

-

-

-

... More
D1 (Single Leaf-Openable Door) with louver size: 600mm x 150mm Size: 1200mm x 2400mm

44

-

-

... More
D2 (Single Leaf-Openable Door) with louver size: 600mm x 150mm Size: 1000mm x 2400mm

185

-

-

... More
D3 (Single Leaf-Openable Door) ( but without provision of lourver Size: 1200mm x 2400mm

3

-

-

... More
Providing and fixing in position seasoned C.P. Teak Wood Frames of section (Approx 65mm x 150mm) as approved by Architect for doors including double grooves on both sides and two rebates for shutters /grills, shaping, jointing, sand papering, applying a coat of bituminous paint on concealed surface, necessary fixing in masonry / RCC by means of HILTI / Equivalent make Anchor fastener, 3 Nos. on each side. Frames to finished with three coats of approved PU polish finishing etc. all material and labour complete.

15

-

-

... More
Modular Glass Doors with Style Supply and Installation of Aluminium Framed Modular Glass Door Single / Double leaf as per specfication mentioned below Door Frame: of extruded section of approved size as per design intent and manufacturers specific. and finished in Matt Anodised Aluminium in approved shade and color as per glass partition frame & door rebate keeping opening as required. Fixing to partition and walls shall be done as per manufactures recommendation. Door Shutter: in 12.5mm clear toughened laminated glass, edges to be mirror polished, with anodized aluminium style finished in approved shade joining Spigot all round the shutter as per manufactures specifications, inclusive of provision for all hardwares, inclusive of provision for all hardwares as per drgs like glass door hinges SS finished as per glass door manufacture, exposed door closer, SS brushed finished door handle with lock, door stopper etc. Rate to be inclusive of SS hinges as per manufactures recommendation but other hardwares shall be paid separately, Rate also to be inclusive of concealled drop down seal of approved make as per manufactures specfications.

-

-

-

... More
SD1 (Single Leaf-Openable Door) l) Size: 900mm x 2100mm

84

-

-

... More
2Hr Fire Rated Glass Partition Supply and Installation of insulated glazed Fire Fixed Partition as per IS 16947 for stability, integrity (E/EW 120) & Insulation (EI 30). Pressed galvanized steel confirming to IS 277 with the following specification. Glazed partition shall be tested to IS/ISO 834-1, IS/ISO 3008-1 for integrity & insulation (E/EW 120). Glazed partition shall be tested from CBRI/ TBW / CERTIFIER for maximum rating of 120mins with 30Mins Insulation. Test certificates should be made available for max door size tested as a complete assembly. Proper label confirming the type of door and the hourly rating is mandatory. Partitions The system is tested as per reputed laboratory. The profiles are manufactured from 2.0 mm galvanized steel sheet pressed formed to a profile of the dimension of 60 x 70 (overall dimension in mm) as by means of M10 x 120 or bigger steel bolts at every 300mm from the edges and every 550 mm (approx) c/c. The glass should be held in its place with the help of minimum 1.25 mm GI beading which can be clamped or bolted to the profile by 4 mm x 35 mm steel screws at every 250 m c/c and a ceramic tape of the cross section of 5 mm x 20 mm as per the test evidence. A 2 mm ceramic paper should be put all around the perimeter of the glass. The glass panes are to be supported on non-combustible 5 mm Calcium Silicate setting blocks. The maximum glazing size cannot be more than 1250mm x 2840mm (w x h) or 3.55 sq. mt in total area as per the test certification. with Contraflam Lite 14mm clear 120min fire rated for Integrity, Radiation control (EW 120) and partially insulation (EI 20) Non Wired Toughened Interlayered glass with a light transmission of 86% and a sound reduction of 38 dB and manufactured in UL & TUV audited Facility and including UL-EU Certification and compliant to class 1(B)1 category of Impact Resistance as per EN 12600. The glass shall provide bi-directional (Symmetrical) fire protection. Rate to be inlcusive of necessary MS framework above the Partition to support the Partition as per manufactures specifications. MS shall be finished with approved paint with anti rust primer.

73

-

-

... More
Rate also to be inclusive of GI Box section of size 150mm x 120mm for Access Control Panel fixing, Box section shall be finished same as per the partition frame.

-

-

-

... More
Supplying and Erecting Pull and Push Type Rolling Shutter with ISI make of approved size and section using 18 GI sheet. The shutter shall be painted with one coat of red oxide primer and the rate is inclusive of hood covers, transportation charges etc

-

-

-

... More
ROLLING GRILLS (WITH ISI MONOGRAM) Gear Operated Type (from 8 sqm. to 12 sqm. Area)

108

-

-

... More
Railing

-

-

-

... More
Steel work Welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc as required - in grating, frames, guard bar, ladder, railings, brackets, gates & similar works ( for Railing works )

1690

-

-

... More
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and appling a priming coat of approved steel primer all complete.

19170

-

-

... More
Fencing with angel iron post placed at required distance embedded in cement concret blocks, every 15th post, last but one end post and corner post hall be strutted on both sides and ed post on one side only and provided with horizontal lines and two diagonal interwoven with horizontal wires, of barbed wire weighin g 9.38 kg per 100m ( miniumum ) between the two post fitted and fixed with GI staples, tum buckles etc complete ( cost of post, struts. earth work and cocrete work to be paid for separately) . Payment to be made per metere cost of tatoal length of barbed wire used .

710

-

-

... More
False ceiling

-

-

-

... More
Note : Contractor shall take approval of the mock up from PMC/Employer before execution of work.

-

-

-

... More
Supplying and Installing Metal False Ceiling using Fire Retardant Galvanized Steel Sheet Plain lay in tile size 600mm x 600mm, 0.5mm thick, powder coated on external surface and shall have flange on all four sides to rest on the exposed grids. The system to give 600mm x 600mm centre to centre ‘T’. The ‘T’ shall be not be dipped GI Tee Section 3600mm long main Tee. 24mm wide and cross Tee panels are formed by running main runner of ‘T’ section of size 30mm x 24mm powder coated at bottom at intervals with powder coating at bottom. Necessary provision of inter locking of ‘T’ section are made at required intervals not exceeding 1200mm. The main runners are suspended from the ceiling by means of 4mm dia. GI rods fixed to the ceiling using anchor fasteners of 50mm x 8mm size with nylon inset and hooked to the main rubbers using clips. The last hangers at end of each rubber should not be greater than 600mm from the adjacent wall. The last panel shall be placed at the side wall using edge profile ‘L’ Angle of size 20mm x 20mm and fixed to the side wall the false ceiling should be fixed of same level and should present a neat look

47

-

-

... More
Providing and constructing 75mm thick Dry Wall Partitions, consisting of the following specifications: Providing & fixing of 48mm C Stud {Material-ASTM A-792-2010, Y/S-310Mpa, Finish - AZ150} 0.5mm thick having unequal flanges of 34mm & 36mm, length 3660mm, placed at 610mm centre to centre in 50 x 0.50mm floor and ceiling channel {Material - ASTM A-792-2010, Y/S-310Mpa, Finish - AZ 150} (0.50mm thick having equal flanges of 32mm made of Steel, length 3660mm), which is anchored to the floor & Soffit/true ceiling using anchor fastener Ø8x40mm Hilti make at 600mm c/c in zigzag manner. Fiixng channel 99 x 9 x 0.90mm {Material-IS277,120GSM galvanizing coating both sides inclusive} has to be provided at every horizontal joint of the outer layer boards & fixed to the studs using Ø4x13 Wafer head Metal to Metal screws. Floor channel to be wrapped with 70μ Self Adhesive LDPE moisture barrier film to further improve corrosion resistance performance. A nogging channel {Material-IS 513,Y/S-300 Mpa, Finish - AZ 150 (IS 15961)} of 48 x 0.5mm width has to be provided at the horizontal joints of the two boards. Providing and fixing Final Skin of Partition, which include of tapered edge 12.5mm thick Regular Gypsum board on both sides from Saint Gobain or USG Boral make. Boards to be screw fixed with drywall screws of 25mm at minimum spacing of 600mm at centre and 600mm at periphery. Finally square and tapered edges of the boards are to be jointed and finished so as to have a flush look which includes filling and finishing with Pro-Fill Jointing compound, (Conforms to ASTM C475), Joint Paper tape or fiber tape. The junction of the partition with masonry & all penetration through the partition has to be treated with Hilti / Pyroplex fire and acoustic sealant. The boards are to be fixed vertically to the framework with joints staggered to avoid leakage through joints. 25mm x 25mm x 0.5mm angle bead should be used at all L-Junctions of partition. Screw fix angle bead at the external corner of drywall and shadow line edge bead at the junction of drywall & column has to be used to get straight line and finish and protection from impacts. Edge bead has to be used to protect the exposed edges of Gypboard. Shadow line beads to be used at the junction of door jambs, glazing, windows etc for giving a clean, straight, shadow edge on installation and finishing.

3644

-

-

... More
Sanitary fitting & accessories

-

-

-

... More
Supply of EWC of approved make and approved colour inlcusive of ('P' / 'S' Trap), complete with chair bracket, flushing tank, CP bolts, seat cover, CP Elbow, CP wall flange, angular stop cocks with flange (for health faucet), health faucet with necessary CP flexible hose 750mm long nozzle, CI brackets, making necessary connection to GI flush / inlet pipe etc. and any necessary accessories including cutting and the making good the walls and floor wherever required. EWC with Seat Cover - Basic Rate Rs 8,000 per Nos Flush Tank - Basic Rate Rs 5,000 per Nos Flush Panel - Basic Rate Rs 800 per Nos Angular Stop Cock - Basic Rate Rs 450 per Nos Health Faucet - Basic Rate Rs 850 per Nos (Rate will be Installation, commissioning and testing of above all items inclusive of any required accessaries, pipes, fittings, transportation and profit margin. ) Flow Rate : Health Faucet -2 LPM Flow Rate: 4/2 LPF Dual Flush

8

-

-

... More
Supply, Installation, commissioning and testing of Wall hung Wash basin inclusive of 15mm dia - 450mm long PVC connection pipe, one no 15mm dia CP angle stop cock with wall flange, 32mm dia CP waste coupling, 32mm dia CP brass bottle trap. The works shall include cutting and making good the walls and floors. Washbasin Wall Hung - Basic Rate Rs 2387 per Nos Sensor Based Cock - Basic Rate Rs 8809 per Nos Angular Stop Cock - Basic Rate Rs 453 per Nos Bottle Trap - Basic Rate Rs 845 per Nos Waste Coupling - Basic Rate Rs 630 per Nos (Rate will be Installation, commissioning and testing of above all items inclusive of any required accessaries, pipes, fittings, transportation and profit margin. ) Flow Rate: 1.4 LPM (max) @ 60 PSI

8

-

-

... More
Supply, Installation and Testing of best quality stainless steel single bowl Sink for pantry, inclusive of angular stop cock, bottle trap, 40mm dia CP waste coupling, 40mm PVC waste pipe as directed by the Architects / Site Incharge. Sink with waste coupling - Basic Rate Rs 8000 per Nos Sink Cock - Basic Rate Rs 1600 per Nos Angular Stop Cock - Basic Rate Rs 453 per Nos Bottle Trap - Basic Rate Rs 845 per Nos (Rate will be Installation, commissioning and testing of above all items inclusive of any required accessaries, pipes, fittings, transportation and profit margin. ) Flow Rate: 1.4 LPM to 2.5LPM (max)@ 60 PSI

1

-

-

... More
Supply and Installation of Grab Bar with 32mm dia, 1.5mm thick SS-304 grade supported on 5mm thick 76mm dia, SS cover with pre-drilled holes for counter sunk screws.

1

-

-

... More
L Type Grab bar

1

-

-

... More
Supply and Installation in position Hand Drier, fixed on wooden cleats with CP brass screws and washers including drilling hole in walls with drill gun and making good the walls.

2

-

-

... More
Supplying and fixing best approved best quality brass CP soap tray of size 150 x 150mm including cost of teak wood plugs, brass screws, etc., complete complying with standard specifications. (The soap tray should be got approved by PMC/Employer before use on works).

2

-

-

... More
Providing and fixing Toilet Paper Holder in CP brass

8

-

-

... More
Supply of Urinals with Sensors of approved make in approved colour supported on bracket with 40mm dia CP waste coupling with dome type grating, 40mm dia CP bottle trap with extension pipe, SS bolts and nuts to fix the urinal with all hangers and brackets complete with wall flanges. Urinal with Sensor - Basic Rate Rs 14500 per Nos (AC operated) (Rate will be Installation, commissioning and testing of above all items inclusive of any required accessaries, pipes, fittings, transportation and profit margin. )

4

-

-

... More
Providing and fixing 600x 450mm belveled edge mirror of superior glass ( of approved quality ) complete with 6mm thick hard board groud fixed to wooden cleates with C.P. Brass screws and washers complete

4

-

-

... More
Providing and fixing Protection Gate

-

-

-

... More
Manufacture, Supply, fabrication and Installation of Motorized Sliding Compound wall Gate as per detail drgs Number of leaves: as per design Mounting surface: as per design Bottom Rail : RCC Columns : RCC / M.S. Gate Design Pattern :Standard Mild Steel square hollow tubular section, torsion free fully welded unit Gate frame:M.S. pipe top/bottom horizontal & vertical profile Infill's : The infill's are to be fully welded between the upper & lower gate frame Cladding : (Optional if any applicable as per gate design) Bottom rail : C channel & 20mm round polished bar Bottom rollers: Italian make Galvanised Wheels 120mm dia.with ball bearings and axle with lubrication point (Appx. weight will be 80kg per Sqm )

-

-

-

... More
Gate 01-Main entry-Two panels Telescopic sliding(equal divisions) - Automatic

19

-

-

... More
Gate 02-Main exit-Two panels Telescopic sliding(equal divisions)

14

-

-

... More
Gate 03-Service entry-Single panel Non-Telescopic sliding

9

-

-

... More
Gate 04-OSR-02-Single panel Non-Telescopic sliding

9

-

-

... More
Gate 05-HSD yard-Single panel Non-Telescopic sliding

9

-

-

... More
Gate 06-OSR-01-Single panel Non-Telescopic sliding

9

-

-

... More
Manufacture, Supply, fabrication and Installation of Swing Type Openable Compound Wall Main gates and wicket gates of specified size and width constructed in MS frames as per design and detailed drawings including all accessories and hardwares and all fabricated and fixed as shown in the drawing, including buffing, painting 3 coats with approved shade epoxy paint over a coat of Zinc chromate primer / Anti corrosive painting etc. complete and all as directed. Rate shall include for fixing in position, alignment, grouting the MS support using cement concrete 1:2:4 and finishing the surface neat and smooth etc. as per drawing and specification complete as directed. Gate should get manufactured in factory & after inspection get dispatched to site except final coat of painting which will be done at site after installation (Appx. weight will be 80kg per Sqm )

-

-

-

... More
Gate 07-Main pedestrian entry-Single panel swing

2

-

-

... More
Gate 08-Service - pedestrian entry-Single panel swing

3

-

-

... More
Gate 09-RMU - pedestrian entry-Single panel swing

1

-

-

... More
FAÇADE WORKS

-

-

-

... More
Note for items of this Section: Designing, providing, fabricating, testing, protection, installing and fixing in position of façade/structural glazing system for all heights and all levels is in the scope of contractor. The façade/glazing system shall be designed for wind load and contractor shall prepare shop drawing based on intent/ concept drawing along with design calculation considering all parameters and submit for the approval of PMC/Employer and shall get approval before mockup/ execution of work. The design calculation of façade/glazing system shall consist of load calculations, design methodology, design of various elements, analysis models such as ETABS/STAAD etc. and contractor shall submit the same to PMC/Employer and get it approved by PMC/Employer before proceeding with execution of work. Shop drawings shall be prepared for the specified design loads conforming to IS 875 part III (the system must pass the proof test at 1.5 times design wind pressure without any failure). Work shall be carried out as per final approved shop drawing and approved mockup. The work shall include cost of all mockups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. Contractor shall provide a watertight structural glazing/facade having all the performance characteristics etc. all complete as required, as per the intent drawing, as per item description, as specified, as per the approved shop drawings and as directed by the PMC/Employer. Contractor shall responsible against stability, safety, leakage, etc all complete.

-

-

-

... More
Conventional Capped Curtain Wall Glazing at double height entrance Design Wind Pressure : 1.20kPa Proof Wind Load : 1.80kPa

-

-

-

... More
Design, fabrication, supply, installation, testing, protection, cleaning & handover of Conventional capped curtain wall system designed to withstand the wind pressure of confirming to IS -875 part III. (The system must pass the proof test at 1.5 times design wind pressure without any failure). The profile system is based on capped curtain wall design and glass is held all around by mechanical pressure plate and cap with microwave cured EPDM gaskets in all four sides of glazing, with necessary brackets of Aluminium alloy of 6005 T5 / MS with HDG with three dimensional adjustment with serrations and serrated washers to arrest the wind load movement, Anchor fasteners, screws and fasteners with non staining weather sealant and Aluminium flashing sealed all around parameter inside and outside to seal the gaps between curtain wall and the building structure all complete required to perform as per specification and drawing in conjunction with BOQ.

-

-

-

... More
Transom shall be overlap with mullion to have proper drainage to mullion. The design to accommodate building movements, thermal expansions & the seismic movements. The system shall be designed considering surface temperatures of 80°C-90°C & temperature differential of 25°C without creating excess stress in the system. All metal joints in the wet area shall be small joint sealant applied to ensure water tightness.

-

-

-

... More
The system shall be designed of floor height units spanning between the floors with Dead load & wind load brackets with provision to accommodate movement at all floor levels and at every grid panels horizontally. The system shall be designed to accommodate 36mm DGU in vision area. System shall accommodate openable panel as per architectural requirement in the system . All fix vision glass and openable shall look similar in the elevation. Aluminium Edge Guard with Black Anodized shall be fixed at all vertical & horizontal grooves. Each glass panel shall be supported for dead load at the bottom of glass with black anodized glass retainers two per panel.

-

-

-

... More
Flashing / Trim / Floor Closure at Parapet level, floor level, beam bottom level and required flashings shall be provided continuously with required GI / Aluminium sheet. Internal & External concealed flashings shall be 1.0mm thk GI sheet. External exposed flashing shall be 3mm thk. Aluminium sheet & internal exposed flashing shall be 2mm thk. Aluminium sheet with powder coated matching with external & internal aluminium profiles respectively.

-

-

-

... More
The extruded aluminium sections of Alloy 6063 T6 & tolerances confirming to DIN / EN standard from approved extruder. The structural profiles shall have minimum 2.5mm wall thickness. All the internal visible surfaces shall have Super Durable Powder coating finish with minimum 60-80 micron confirming to AAMA 2604. External capping & visible surfaces shall be PVDF coating with minimum coating thickness of 30-35microns confirming to AAMA 2605. The non visible aluminium surfaces shall have minimum chromatizing treatment.

-

-

-

... More
The system shall have PVDF Coated vertical & horizontal capping of 20mm deep visible in the elevation. End Cover plate to be fix in vertical & horizontal capping

-

-

-

... More
All Material Make / Vendor list / Supplier list shall be as per tender specification. Acceptance of equivalent makes is subject to prior approval from PMC/Employer.

-

-

-

... More
All shade approval shall be as per PMC/Employer Approval.

-

-

-

... More
The system shall demonstrate performance for air seal / water seal / structural /seismic requirement.

-

-

-

... More
Aluminium's stress utilization, MS utilization & anchors utilization shall not exceeding 90%.

-

-

-

... More
The quote rate shall include all design, engineering & shop drawing approval from architect & consultant. The quote rate shall include all taxes, duties, statutory obligations and safety code compliance as per PMC.

-

-

-

... More
Conventional Capped Curtain Wall System Quote rate for complete system as mentioned above under (2.10.1 )

942

-

-

... More
Vision Glass : Extra over 2.10.1 a Quote extra over on item (2.10.1 a) for providing and fixing 36mm thick DGU 10mm Low-e HS + 16mm Air Gap + 10mm Clear HS Appearance : As per Client / Architect's approval VLT : 45% - 70% SHGC 0.25 (LEED requirement) U Value 1.7 W/m2K (LEED requirement)

942

-

-

... More
Automatic Sliding Door : Extra over 2.10.1 a Providing and fixing Compact automatic linear sliding door, TÜV type-tested as per DIN 18650, with self-cleaning rollers, for leaf weights up to 120 kg per leaf System shall have following specifications : • Integrated battery pack for emergency opening or closing in case of power failure • Intelligent digital DCU controller (category 2 as per DIN EN 954-1): • Self-learning • With dynamic adjustment of hold-open time on traffic for optimal comfort • Network able and integrable in building systems • Error self-detection and logging • All movement parameters can be adjusted • Extremely quiet DC drive • Rugged transformer with integrated all poles disconnecting main switch and fuse protection • Static and dynamic force limitation as per new DIN 18650 and under 150 N as per BGR 232 (formerly ZH 1/494) • Automatic reversing on obstacle detection System to hav continuous floor guide, made of anodised E6/EV1 aluminium, can be installed flush to ground, guide rail can be removed for cleaning. Shall also have a rain water drain option. Quote rate for complete system as mentioned above with 12mm Clear FT Heat Soaked Glass 2205mm (W) x 2700mm (H) = 2 Nos.

3

-

-

... More
MS Tonnage: Inserts to suffice the structural requirement of profiles Design, Fabrication, Supply and install required structural steel frame work in line with design drawings made out of MS pipe sections / I Beams / Channels / Plates of approved make make of first quality confirming to IS standard. The steel design shall accommodate thermal stresses resulting from thermal expansion due to surface temperatures. The steel structure shall be finish with the following, i. Surface Preparation – Blast cleaned to Sa 2.5 confirming to BS EN ISO 8501-1 ii. Primer : Zinc Rich Epoxy 75 micron iii. Barrier : Epoxy Mio 125 micron iv. Finish : Polyurethane – 50 Micron (Only for exposed steel)

16

-

-

... More
Semi Unitized Structural Glazing with Horizontal Fin Design Wind Pressure : 1.20kPa Proof Wind Load : 1.80kPa

-

-

-

... More
Design, fabrication, supply, installation, testing, protection, cleaning & handover of Semi-Unitized four sided structurally glazed curtain wall system custom designed to withstand the design wind pressure confirming to IS-875 part III. (The system must pass the proof test at 1.5 times design wind pressure without any failure) with microwave cured EPDM gaskets, Two-part structural sealant & non-staining, non-bleeding weather sealants, Open PU cell Spacer tape, backer rod, face mounted / slab mounted bracketing system with MS hot dip galvanized / aluminium Alloy of 6005 T5 brackets designed to accommodate three dimensional movements with serrated plate and serrated washers, building plump tolerances as per structural DBR, SS 316 grade fasteners & SS316 anchor fasteners (designed as per cracked concrete condition), nylon / hard PVC separators (upto 3mm and beyond 3mm GI shims which should be tack welded to act monolithic) to prevent bi-metallic contacts, aluminium trims and flashings to seal the gaps between curtain wall and the building structure all complete required to perform as per specification and drawing in conjunction with BOQ.

-

-

-

... More
The system design shall be based on open joint system principle & design shall also include pressure equalization with minimum 3 barrier gaskets for improved weather performance, drainage at all floor levels, spandrel panel shall have condenstion slots & weep holes on vertical side of profile system to avoid condensation. The design to accommodate building movements, thermal expansions & the seismic movements. The system shall be designed considering surface temperatures of 80°C - 90C° & differential temperature of 25°C without creating excess stress in the system. All metal joints in the wet area shall be small joint sealant applied to ensure water tightness. The system shall have transom overlap principle which facilitates the water from transom gutter to flow directly into the mullion gutter, hence avoid water seepage through mullion - transom junction.

-

-

-

... More
The system shall be designed of floor height units spanning between the floors with face / slab mounted brackets or hook-on bracket on mullion with provision to accommodate movement at all floor levels and at every grid panels horizontally. System shall be mounted on to the bracket arrangement with the help of SS316 anchor fasteners. The bracketing system with aluminium alloy / MS HDG with built in serration & serrated washers. The system shall be designed to accommodate 32mm DGU in vision area & 6mm SGU in spandrel area at all floor level. The spandrel panel shall have aluminium adaptor profile to balance the DGU and SGU glass thickness in black anodized. System shall accommodate openable panel as per architectural requirement in the unitized system. All fix vision glass and openable shall look similar in the elevation. Aluminium Edge Guard shall be fixed at all vertical & horizontal grooves. Each glass panel shall be structurally glazed on the main unitized profile system . Each glass panel shall be supported for dead load at the bottom of glass with black anodized glass retainers two per panel.

-

-

-

... More
The three barrier gasket system consists of 1st Barrier of Silicon Gasket and 2nd & 3rd barrier of EPDM gaskets to achieve the required compression & seal in the system. Gaskets shall be of microwave cured (Online Curing) with shore A hardness of 60-65.

-

-

-

... More
Flashing / Trim / Floor Closure at Parapet level, floor level, beam bottom level and required flashings shall be provided continuously with required GI / Aluminium sheet. Internal & External concealed Flashings shall be 1.2mm thk GI sheet. Internal & External exposed flashing shall be 2.5mm thk. aluminium sheet with coating matching with internal & external Aluminium profiles respectively.

-

-

-

... More
Termination of systems with civil or adjoining MS structure shall have one layer of vertical continuous EPDM membrane with 1.2mm thick GI flashing ensuring water and air tightness.

-

-

-

... More
The extruded aluminium sections of Alloy 6063 T5 / T6 & tolerances confirming to DIN / EN standard from approved extruder. The structural profiles shall have minimum 2.5mm wall thickness. All the internal visible surfaces shall have high Durability (Akzonobel) / Super durable (Jotun) Powder coating of 60 - 80 micron confirming to AAMA 2604 & all externally visible surfaces shall have PVDF finish with minimum 35 micron confirming to AAMA 2605. The non visible aluminium surfaces shall have minimum chromatizing treatment.

-

-

-

... More
All Material Make / Vendor list / Supplier list shall be as per tender specification. (Annexure 1). Acceptance of equivalent makes is subject to prior approval from client / PMC / architect / consultant.

-

-

-

... More
All shade approval shall be as per client / architect's Approval.

-

-

-

... More
The system shall demonstrate performance for air seal / water seal / structural /seismic requirement.

-

-

-

... More
Aluminium's stress utilization, MS utilization & anchors utilization shall not exceeding 90%.

-

-

-

... More
The quote rate shall include all design, engineering & shop drawing approval from architect & consultant. The quote rate shall include all taxes, duties, statutory obligations and safety code compliance as per PMC.

-

-

-

... More
Semi-Unitized structural glazing curtain wall system Quote rate for complete hardware as mentioned above under (2.10.2)

454

-

-

... More
Semi-Unitized structural glazing curtain wall system Quote rate for complete Aluminium as mentioned above under (2.10.2)

3159

-

-

... More
Spandrel panel : Extra over 2.10.2 a (behind spandrel glass) Quote extra over on item (2.10.2 a) for providing and fixing the spandrel panel with the thermal insulation of thickness and density slab as per firestop and smoke seal suppliers EJ / test certificates firmly held on the powder coated GI tray (thickness of GI tray as per firestop and smoke seal suppliers EJ / test certificates). The assembly is kept atleast 50mm away from the glass surface. The spandrel insulation to have front face as 2mm thick powder coated alum. tray, powder coating shade to be as per architect's intent

189

-

-

... More
Spandrel panel : Extra over 2.10.2 a (at top Fibre Cement Sheet) Quote extra over on item (2.10.2 a) for providing and fixing the spandrel panel with the 50mm thick Glasswool insulation of density 48kg/m3 held firmly by 1.2mm thick GI tray on both sides.

81

-

-

... More
Fire Stop : Extra over 2.10.2 a (Horizontal smoke seal at floor perimeter) Quote extra over on item (2.10.2 a) for providing and fixing the tested fire stop for 120min rating with smoke seal at all floor slab levels required as per local fire authority. Voids created between the fire resistance rate floor assembly and the exterior curtain wall shall be protected with a perimeter joint that is designed and tested in accordance with ASTM E 2307 – As per NFPA 101 : Life Safety Code. The fire stop assembly shall run vertical side where there is a shear wall condition or break in horizontal fire stop. The floor closure shall be provided continuously at floor level with 1.2mm thk GI flashing closing gap between transom and building line. Super Durable Powder coated 2mm thick Aluminium flashing shall be provided at the soffit to provide a proper closure at soffit level between the insulation tray and building line.

90

-

-

... More
Top Hung Openable window : Extra over 2.10.2 a Quote extra over on item (2.10.2 a) for providing & fixing the Top Hung Open Out (operable) vent, accessories with heavy duty self balancing stainless steel friction hinges with provision to hold open at 250mm. Vent locking accessories with Cremone lock and handle with multi point locking (with minimum 2 typhoon locks / as recommended by the hardware manufacturer) mechanism to keep the vent weather tight. The vent shall comprise of Aluminium outer frame with drainage provisions, crimped corner & shutter frame with Euro grooves with crimped corners. The outer frame fixed to the unitized profile system with necessary SS screws & weather sealant applied from outside. The stepped glass design vent shall have ceramic frit in black at the portion of the stepped unit in case of high light transmission glass to reduce banding effect in the glazing .

20

-

-

... More
Fibre Cement Board Cladding : Extra over 2.10.2 a Quote extra over on item (2.10.2 a) for providing and fixing 12mm thick Paintable fibre cement board. The paint on the fibre cement board shall be as per architect's intent. Surface should be free to receive any RAL shade chosen by the architect. The cement board shall be held by necessary alum angle as per tender drawings.

81

-

-

... More
Internal Alum. Floor closure extrusion at bund level : Extra over 2.10.2 a Quote extra over on item (2.10.2 a) for providing and fixing min. 1.8mm thick aluminium extruded members at skirting / bund / slab level in-line with tender drawings. Internally visible surfaces shall have Super Durable Powder coating finish with minimum 60-80 micron confirming to AAMA 2604. The non visible aluminium surfaces shall have minimum chromatizing treatment.

90

-

-

... More
MS Tonnage (Considered 8 kg/sqm of Unitized glazing area) : Suspended supports to support the Unitized Glazing from top Design, Fabrication, Supply and install required structural steel frame work in line with design drawings for made out of MS pipe sections / I Beams / Channels / Plates of approved make make of first quality confirming to IS standard. The steel design shall accommodate thermal stresses resulting from thermal expansion due to surface temperatures. The steel structure shall be finish with the following, i. Surface Preparation – Blast cleaned to Sa 2.5 confirming to BS EN ISO 8501-1 ii. Primer : Zinc Rich Epoxy 75 micron iii. Barrier : Epoxy Mio 125 micron iv. Finish : Polyurethane – 50 Micron (Only for exposed steel)

4

-

-

... More
Vision Glass : Extra over 2.10.2 a Quote extra over on item (2.10.2 a) for providing and fixing 32mm thick DGU 8mm Low-e HS + 16mm Air Gap + 8mm Clear HS Appearance : As per Client / Architect's approval VLT : 45% - 70% SHGC 0.25 (LEED requirement) U Value 1.7 W/m2K (LEED requirement)

266

-

-

... More
Spandrel Glass : Extra over 2.10.2 a Quote extra over on item (2.10.2 a) for providing and fixing 6mm thick Ref. SGU (as per PMC/Employer approval)

189

-

-

... More
40mm x 150mm Horizontal Fin : Extra over 2.10.2 a Quote extra over on item (2.10.2 a) for providing and fixing PVDF coated horizontal rectangular extrusion profile of size 40mm x 150mm.

90

-

-

... More
Conventional Capped Curtain Wall Glazing at Cafeteria Design Wind Pressure : 1.20kPa Proof Wind Load : 1.80kPa

-

-

-

... More
Design, fabrication, supply, installation, testing, protection, cleaning & handover of Conventional capped curtain wall system designed to withstand the wind pressure of confirming to IS -875 part III. (The system must pass the proof test at 1.5 times design wind pressure without any failure). The profile system is based on capped curtain wall design and glass is held all around by mechanical pressure plate and cap with microwave cured EPDM gaskets in all four sides of glazing, with necessary brackets of Aluminium alloy of 6005 T5 / MS with HDG with three dimensional adjustment with serrations and serrated washers to arrest the wind load movement, Anchor fasteners, screws and fasteners with non staining weather sealant and Aluminium flashing sealed all around parameter inside and outside to seal the gaps between curtain wall and the building structure all complete required to perform as per specification and drawing in conjunction with BOQ.

-

-

-

... More
Transom shall be overlap with mullion to have proper drainage to mullion. The design to accommodate building movements, thermal expansions & the seismic movements. The system shall be designed considering surface temperatures of 80°C-90°C & temperature differential of 25°C without creating excess stress in the system. All metal joints in the wet area shall be small joint sealant applied to ensure water tightness.

-

-

-

... More
The system shall be designed of floor height units spanning between the floors with Dead load & wind load brackets with provision to accommodate movement at all floor levels and at every grid panels horizontally. The system shall be designed to accommodate 32mm DGU in vision area & 6mm SGU glass spandrel panel. System shall accommodate openable panel as per architectural requirement in the system . All fix vision glass and openable shall look similar in the elevation. Aluminium Edge Guard with Black Anodized shall be fixed at all vertical & horizontal grooves. Each glass panel shall be supported for dead load at the bottom of glass with black anodized glass retainers two per panel.

-

-

-

... More
Flashing / Trim / Floor Closure at Parapet level, floor level, beam bottom level and required flashings shall be provided continuously with required GI / Aluminium sheet. Internal & External concealed Flashings shall be 1.0mm thk GI sheet. External exposed flashing shall be 3mm thk. Aluminium sheet & internal exposed flashing shall be 2mm thk. Aluminium sheet with powder coated matching with internal aluminium profiles.

-

-

-

... More
The extruded aluminium sections of Alloy 6063 T6 & tolerances confirming to DIN / EN standard from approved extruder. The structural profiles shall have minimum 2.5mm wall thickness. All the internal visible & all externally visible surfaces shall have Super Durable Powder coating finish with minimum 60-80 micron confirming to AAMA 2604. External capping shall be PVDF coating with minimum coating thickness of 30-35microns confirming to AAMA 2605. The non visible aluminium surfaces shall have minimum chromatizing treatment.

-

-

-

... More
The system shall have PVDF Coated vertical capping of 20mm & horizontal capping of 15mm deep visible in the elevation. End Cover plate to be fix in vertical & horizontal capping

-

-

-

... More
All Material Make / Vendor list / Supplier list shall be as per tender specification. Acceptance of equivalent makes is subject to prior approval from PMC/Employer.

-

-

-

... More
All shade approval shall be as per PMC/Employer Approval.

-

-

-

... More
The system shall demonstrate performance for air seal / water seal / structural /seismic requirement.

-

-

-

... More
Aluminium's stress utilization, MS utilization & anchors utilization shall not exceeding 90%.

-

-

-

... More
The quote rate shall include all design, engineering & shop drawing approval from architect & consultant. The quote rate shall include all taxes, duties, statutory obligations and safety code compliance as per PMC.

-

-

-

... More
Conventional Capped Curtain Wall System Quote rate for complete system as mentioned above under (2.10.3 )

958

-

-

... More
Vision Glass : Extra over 2.10.3 a Quote extra over on item (2.10.3 a ) for providing and fixing 32mm thick DGU 8mm Low-e HS + 16mm Air Gap + 8mm Clear HS Appearance : As per Client / Architect's approval VLT : 45% - 70% SHGC 0.25 (LEED requirement) U Value 1.7 W/m2K (LEED requirement)

821

-

-

... More
Spandrel Glass : Extra over 2.10.3 a Quote extra over on item (2.10.3 a ) for providing and fixing 6mm thick Ref. SGU (as per PMC/Employer approval)

39

-

-

... More
Fire Stop : Extra over 2.10.3 a (Horizontal smoke seal at floor perimeter) Quote extra over on item (2.10.3 a) for providing and fixing the tested fire stop for 120min rating with smoke seal at all floor slab levels required as per local fire authority. Voids created between the fire resistance rate floor assembly and the exterior curtain wall shall be protected with a perimeter joint that is designed and tested in accordance with ASTM E 2307 – As per NFPA 101 : Life Safety Code. The fire stop assembly shall run vertical side where there is a shear wall condition or break in horizontal fire stop. The floor closure shall be provided continuously at floor level with 1.2mm thk GI flashing closing gap between transom and building line. Super Durable Powder coated 2mm thick Aluminium flashing shall be provided at the soffit to provide a proper closure at soffit level between the insulation tray and building line.

33

-

-

... More
Spandrel panel : Extra over 2.10.3 a (behind spandrel glass) Quote extra over on item (2.10.3 a ) for providing and fixing the spandrel panel with the thermal insulation of thickness and density slab as per firestop and smoke seal suppliers EJ / test certificates firmly held on the powder coated GI tray (thickness of GI tray as per firestop and smoke seal suppliers EJ / test certificates). The assembly is kept atleast 50mm away from the glass surface. The spandrel insulation to have front face as 2mm thick powder coated alum. tray, powder coating shade to be as per architect's intent

39

-

-

... More
Spandrel insulation : Extra over 2.10.3 a (at top Fibre Cement Sheet) Quote extra over on item (2.10.3 a ) for providing and fixing the spandrel panel with the 50mm thick Glasswool insulation of density 48kg/m3 held firmly by 1.2mm thick GI tray on both sides.

99

-

-

... More
Fibre Cement Board Cladding : Extra over 2.10.3 a Quote extra over on item (2.10.3 a ) for providing and fixing 12mm thick Paintable fibre cement board. The paint on the fibre cement board shall be as per architect's intent. Surface should be free to receive any RAL shade chosen by the architect. The cement board shall be held by necessary alum angle as per tender drawings.

99

-

-

... More
Top Hung Openable window : Extra over 2.10.3 a Quote extra over on item (2.10.3 a ) for providing & fixing the Top Hung Open Out (operable) vent, accessories with heavy duty self balancing stainless steel friction hinges with provision to hold open at 250mm. Vent locking accessories with Cremone lock and handle with multi point locking (with minimum 2 typhoon locks / as recommended by the hardware manufacturer) mechanism to keep the vent weather tight. The vent shall comprise of Aluminium outer frame with drainage provisions, crimped corner & shutter frame with Euro grooves with crimped corners. The outer frame fixed to the unitized profile system with necessary SS screws & weather sealant applied from outside. The stepped glass design vent shall have ceramic frit in black at the portion of the stepped unit in case of high light transmission glass to reduce banding effect in the glazing .

27

-

-

... More
MS Tonnage (Considered 8 kg/sqm of CCW glazing area) : Suspended supports to support the Glazing from top Design, Fabrication, Supply and install required structural steel frame work in line with design drawings for made out of MS pipe sections / I Beams / Channels / Plates of approved make make of first quality confirming to IS standard. The steel design shall accommodate thermal stresses resulting from thermal expansion due to surface temperatures. The steel structure shall be finish with the following, i. Surface Preparation – Blast cleaned to Sa 2.5 confirming to BS EN ISO 8501-1 ii. Primer : Zinc Rich Epoxy 75 micron iii. Barrier : Epoxy Mio 125 micron iv. Finish : Polyurethane – 50 Micron (Only for exposed steel)

7

-

-

... More
Aluminium Framed Door Quote extra over on item (2.10.3 a ) for providing & fixing single leaf aluminium framed door door opening outward / inward (as per tender drawings) custom designed to withstand the design wind pressure. The system shall have two barrier gasket system for weather sealing & provision for aluminium thrash hold at bottom. The profile system shall be of minimum 2.5mm thickness. Door shutter shall have crimped corner at top and SS tie rod at bottom for rigid connection. The system shall have hydraulic door closure mounted on the profiles, three leaf projected type hinges of approved make, Microwave cured EPDM gaskets .Door shutter profile to accommodate the 12mm clear FT glass, weather sealants, SS 316 grade screws and fasteners of approved make, all in complete required to perform as per specification and drawing in conjunction with BOQ. Quote rate for complete system as mentioned above with fittings and door closure including 12mm clear FT - Single Shutter (Size : 1225mm X 3000mm)

3

-

-

... More
3mm thick Solid Alum sheet column cladding Design Wind Pressure : 1.20kPa Proof Wind Load : 1.80kPa

-

-

-

... More
Design, fabrication, supply, installation, testing , protection, cleaning & handover of aluminium sheet cladding of approved make in solid or metallic colours as per architect's approval Using grid work of prefabricated aluminium extruded sections to withstand the design wind pressure confirming to IS -875 part III. (The system must pass the proof test at 1.5 times design wind pressure). The fastening brackets of Aluminium alloy 6005 T5 / MS with HDG with serrations and serrated washers to arrest the wind load movement, fasteners and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing in conjunction with BOQ.

-

-

-

... More
Prefabricated grid mullions are fixed on to the RCC and concrete masonry walls with SS 316 anchor bolts as recommended by approved supplier to support given design loads. The brackets shall have provision movement to accommodate the construction tolerances with + 35mm plumb in case of RCC structure and + 20mm plumb incase of steel structure. Use of aluminium brackets with serration and serrated washers to prevent wind direction movement after final position. Use of Hot Dipped galvanized brackets with serrations and serrated washers on to Steel structures.

-

-

-

... More
The design to accommodate building movements, thermal expansions & the seismic movements. The system shall be designed considering surface temperatures of 80°C-90°C & temperature differential of 25°C without creating excess stress in the system. All metal joints in the wet area shall be small joint sealant applied to ensure water tightness.

-

-

-

... More
The extruded aluminium sections of Alloy 6063 T6 & tolerances confirming to DIN / EN standard from approved extruder. The structural profiles shall have minimum 2.5mm wall thickness. The non visible aluminium surfaces shall have minimum chromatizing treatment.

-

-

-

... More
All Material Make / Vendor list / Supplier list shall be as per tender specification. Acceptance of equivalent makes is subject to prior approval from PMC/Employert.

-

-

-

... More
All shade approval shall be as per PMC/EmployerApproval.

-

-

-

... More
The system shall demonstrate performance for air seal / water seal / structural /seismic requirement.

-

-

-

... More
Aluminium's stress utilization, MS utilization & anchors utilization shall not exceeding 90%.

-

-

-

... More
The quote rate shall include all design, engineering & shop drawing approval from architect & consultant. The quote rate shall include all taxes, duties, statutory obligations and safety code compliance as per PMC.

-

-

-

... More
Quote rate for complete system as mentioned above under (2.10.4)

2029

-

-

... More
Semi Unitized Structural Glazing with Vertical Fins - North West, North East, South West, South East Design Wind Pressure : 1.55kPa Proof Wind Load : 2.32kPa

-

-

-

... More
Design, fabrication, supply, installation, testing, protection, cleaning & handover of Semi-Unitized four sided structurally glazed curtain wall system custom designed to withstand the design wind pressure confirming to IS-875 part III. (The system must pass the proof test at 1.5 times design wind pressure without any failure) with microwave cured EPDM gaskets, Two-part structural sealant & non-staining, non-bleeding weather sealants, Open PU cell Spacer tape, backer rod, face mounted / slab mounted bracketing system with MS hot dip galvanized / aluminium Alloy of 6005 T5 brackets designed to accommodate three dimensional movements with serrated plate and serrated washers, building plump tolerances as per structural DBR, SS 316 grade fasteners & SS316 anchor fasteners (designed as per cracked concrete condition), nylon / hard PVC separators (upto 3mm and beyond 3mm GI shims which should be tack welded to act monolithic) to prevent bi-metallic contacts, aluminium trims and flashings to seal the gaps between curtain wall and the building structure all complete required to perform as per specification and drawing in conjunction with BOQ.

-

-

-

... More
The system design shall be based on open joint system principle & design shall also include pressure equalization with minimum 3 barrier gaskets for improved weather performance, drainage at all floor levels, spandrel panel shall have condenstion slots & weep holes on vertical side of profile system to avoid condensation. The design to accommodate building movements, thermal expansions & the seismic movements. The system shall be designed considering surface temperatures of 80°C - 90C° & differential temperature of 25°C without creating excess stress in the system. All metal joints in the wet area shall be small joint sealant applied to ensure water tightness. The system shall have transom overlap principle which facilitates the water from transom gutter to flow directly into the mullion gutter, hence avoid water seepage through mullion - transom junction.

-

-

-

... More
The system shall be designed of floor height units spanning between the floors with face / slab mounted brackets or hook-on bracket on mullion with provision to accommodate movement at all floor levels and at every grid panels horizontally. System shall be mounted on to the bracket arrangement with the help of SS316 anchor fasteners. The bracketing system with aluminium alloy / MS HDG with built in serration & serrated washers. The system shall be designed to accommodate 32mm DGU in vision area & 6mm SGU in spandrel area at all floor level. The spandrel panel shall have aluminium adaptor profile to balance the DGU and SGU glass thickness in black anodized. System shall accommodate openable panel as per architectural requirement in the unitized system. All fix vision glass and openable shall look similar in the elevation. Aluminium Edge Guard shall be fixed at all vertical & horizontal grooves. Each glass panel shall be structurally glazed on the main unitized profile system . Each glass panel shall be supported for dead load at the bottom of glass with black anodized glass retainers two per panel.

-

-

-

... More
The three barrier gasket system consists of 1st Barrier of Silicon Gasket and 2nd & 3rd barrier of EPDM gaskets to achieve the required compression & seal in the system. Gaskets shall be of microwave cured (Online Curing) with shore A hardness of 60-65.

-

-

-

... More
Flashing / Trim / Floor Closure at Parapet level, floor level, beam bottom level and required flashings shall be provided continuously with required GI / Aluminium sheet. Internal & External concealed Flashings shall be 1.2mm thk GI sheet. Internal & External exposed flashing shall be 2.5mm thk. aluminium sheet with coating matching with internal & external Aluminium profiles respectively.

-

-

-

... More
Termination of systems with civil or adjoining MS structure shall have one layer of vertical continuous EPDM membrane with 1.2mm thick GI flashing ensuring water and air tightness.

-

-

-

... More
The extruded aluminium sections of Alloy 6063 T5 / T6 & tolerances confirming to DIN / EN standard from approved extruder. The structural profiles shall have minimum 2.5mm wall thickness. All the internal visible surfaces shall have high Durability (Akzonobel) / Super durable (Jotun) Powder coating of 60 - 80 micron confirming to AAMA 2604 & all externally visible surfaces shall have PVDF finish with minimum 35 micron confirming to AAMA 2605. The non visible aluminium surfaces shall have minimum chromatizing treatment.

-

-

-

... More
All Material Make / Vendor list / Supplier list shall be as per tender specification. (Annexure 1). Acceptance of equivalent makes is subject to prior approval from client / PMC / architect / consultant.

-

-

-

... More
All shade approval shall be as per client / architect's Approval.

-

-

-

... More
The system shall demonstrate performance for air seal / water seal / structural /seismic requirement.

-

-

-

... More
Aluminium's stress utilization, MS utilization & anchors utilization shall not exceeding 90%.

-

-

-

... More
The quote rate shall include all design, engineering & shop drawing approval from architect & consultant. The quote rate shall include all taxes, duties, statutory obligations and safety code compliance as per PMC.

-

-

-

... More
Semi-Unitized structural glazing curtain wall system Quote rate for complete hardware as mentioned above under (2.10.2)

13079

-

-

... More
Semi-Unitized structural glazing curtain wall system Quote rate for complete Aluminium as mentioned above under (2.10.2)

90991

-

-

... More
Spandrel panel : Extra over 2.10.5 a (behind spandrel glass) Quote extra over on item (2.10.5 a) for providing and fixing the spandrel panel with the thermal insulation of thickness and density slab as per firestop and smoke seal suppliers EJ / test certificates firmly held on the powder coated GI tray (thickness of GI tray as per firestop and smoke seal suppliers EJ / test certificates). The assembly is kept atleast 50mm away from the glass surface. The spandrel insulation to have front face as 2mm thick powder coated alum. tray, powder coating shade to be as per architect's intent

3795

-

-

... More
Fire Stop : Extra over 2.10.5 a (Horizontal smoke seal at floor perimeter) Quote extra over on item (2.10.5 a) for providing and fixing the tested fire stop for 120min rating with smoke seal at all floor slab levels required as per local fire authority. Voids created between the fire resistance rate floor assembly and the exterior curtain wall shall be protected with a perimeter joint that is designed and tested in accordance with ASTM E 2307 – As per NFPA 101 : Life Safety Code. The fire stop assembly shall run vertical side where there is a shear wall condition or break in horizontal fire stop. The floor closure shall be provided continuously at floor level with 1.2mm thk GI flashing closing gap between transom and building line. Super Durable Powder coated 2mm thick Aluminium flashing shall be provided at the soffit to provide a proper closure at soffit level between the insulation tray and building line.

3084

-

-

... More
Top Hung Openable window : Extra over 2.10.5 a Quote extra over on item (2.10.5 a) for providing & fixing the Top Hung Open Out (operable) vent, accessories with heavy duty self balancing stainless steel friction hinges with provision to hold open at 250mm. Vent locking accessories with Cremone lock and handle with multi point locking (with minimum 2 typhoon locks / as recommended by the hardware manufacturer) mechanism to keep the vent weather tight. The vent shall comprise of Aluminium outer frame with drainage provisions, crimped corner & shutter frame with Euro grooves with crimped corners. The outer frame fixed to the unitized profile system with necessary SS screws & weather sealant applied from outside. The stepped glass design vent shall have ceramic frit in black at the portion of the stepped unit in case of high light transmission glass to reduce banding effect in the glazing .

541

-

-

... More
Vision Glass : Extra over 2.10.5 a Quote extra over on item (2.10.5 a) for providing and fixing 32mm thick DGU 8mm Low-e HS + 16mm Air Gap + 8mm Clear HS Appearance : As per Client / Architect's approval VLT : 45% - 70% SHGC 0.25 (LEED requirement) U Value 1.7 W/m2K (LEED requirement)

9285

-

-

... More
Spandrel Glass : Extra over 2.10.5 a Quote extra over on item (2.10.5 a) for providing and fixing 6mm thick Ref. SGU (as per PMC/Employer approval)

3795

-

-

... More
40mm x 150mm Vertical Fin : Extra over 2.10.5 a Quote extra over on item (2.10.5 a) for providing and fixing PVDF coated vertical rectangular extrusion profile of size 40mm x 150mm.

11036

-

-

... More
Aluminium Framed Door Quote extra over on item (2.10.5 a) for providing & fixing single leaf aluminium framed door door opening outward / inward (as per tender drawings) custom designed to withstand the design wind pressure. The system shall have two barrier gasket system for weather sealing & provision for aluminium thrash hold at bottom. The profile system shall be of minimum 2.5mm thickness. Door shutter shall have crimped corner at top and SS tie rod at bottom for rigid connection. The system shall have hydraulic door closure mounted on the profiles, three leaf projected type hinges of approved make, Microwave cured EPDM gaskets .Door shutter profile to accommodate the 12mm clear FT glass, weather sealants, SS 316 grade screws and fasteners of approved make, all in complete required to perform as per specification and drawing in conjunction with BOQ. Quote rate for complete system as mentioned above With fittings and panic device under item ( L) including 12mm clear FT - Double Shutter (Size : 1225mm X 3000mm)

13

-

-

... More
MS Tonnage (Glazing at terrace level glazing & terrace copping) Design, Fabrication, Supply and install required structural steel frame work in line with design drawings for made out of MS pipe sections / I Beams / Channels / Plates of approved make make of first quality confirming to IS standard. The steel design shall accommodate thermal stresses resulting from thermal expansion due to surface temperatures. The steel structure shall be finish with the following, i. Surface Preparation – Blast cleaned to Sa 2.5 confirming to BS EN ISO 8501-1 ii. Primer : Zinc Rich Epoxy 75 micron iii. Barrier : Epoxy Mio 125 micron iv. Finish : Polyurethane – 50 Micron (Only for exposed steel)

5

-

-

... More
Terrace Copping Quote extra over on item (2.10.5 a) for Installation of ACP Copping at terrace level sealing the top gap between the curtain wall & parapet top. ACP Panel shall have GI stiffners below with required Aluminium grid work with necessary MS HDG / Aluminium alloy brackets & fasteners in SS 316. 2nd barrier of 1mm thk GI sheet laid contineously below the copping to seal the parapet & Unitised curtain wall. Overlap of GI sheet shall be properly sealed with weather sealant. The grooves between two copping panels shall be filled with non staining weather selant complete as per drawing and specification. The groove sealed joint to be covered by 2mm thk 60 mm wide Aluminium / ACP strip to protect the sealant detorioration.

325

-

-

... More
Internal Alum. Floor closure extrusion at bund level : Extra over 2.10.5 a Quote extra over on item (2.10.5 a) for providing and fixing min. 1.8mm thick aluminium extruded members at skirting / bund / slab level in-line with tender drawings. Internally visible surfaces shall have Super Durable Powder coating finish with minimum 60-80 micron confirming to AAMA 2604. The non visible aluminium surfaces shall have minimum chromatizing treatment.

3084

-

-

... More
3mm thick Solid Alum sheet soffit cladding Design Wind Pressure : 1.55kPa Proof Wind Load : 2.32kPa

-

-

-

... More
Design, fabrication, supply, installation, testing , protection, cleaning & handover of aluminium sheet cladding of approved make in solid or metallic colours as per architect's approval Using grid work of prefabricated aluminium extruded sections to withstand the design wind pressure confirming to IS -875 part III. (The system must pass the proof test at 1.5 times design wind pressure). The fastening brackets of Aluminium alloy 6005 T5 / MS with HDG with serrations and serrated washers to arrest the wind load movement, fasteners and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing in conjunction with BOQ.

-

-

-

... More
Prefabricated grid mullions are fixed on to the RCC and concrete masonry walls with SS 316 anchor bolts as recommended by approved supplier to support given design loads. The brackets shall have provision movement to accommodate the construction tolerances with + 35mm plumb in case of RCC structure and + 20mm plumb incase of steel structure. Use of aluminium brackets with serration and serrated washers to prevent wind direction movement after final position. Use of Hot Dipped galvanized brackets with serrations and serrated washers on to Steel structures.

-

-

-

... More
The design to accommodate building movements, thermal expansions & the seismic movements. The system shall be designed considering surface temperatures of 80°C-90°C & temperature differential of 25°C without creating excess stress in the system. All metal joints in the wet area shall be small joint sealant applied to ensure water tightness.

-

-

-

... More
The extruded aluminium sections of Alloy 6063 T6 & tolerances confirming to DIN / EN standard from approved extruder. The structural profiles shall have minimum 2.5mm wall thickness. The non visible aluminium surfaces shall have minimum chromatizing treatment.

-

-

-

... More
All Material Make / Vendor list / Supplier list shall be as per tender specification. Acceptance of equivalent makes is subject to prior approval from PMC/Employert.

-

-

-

... More
All shade approval shall be as per PMC/EmployerApproval.

-

-

-

... More
The system shall demonstrate performance for air seal / water seal / structural /seismic requirement.

-

-

-

... More
Aluminium's stress utilization, MS utilization & anchors utilization shall not exceeding 90%.

-

-

-

... More
The quote rate shall include all design, engineering & shop drawing approval from architect & consultant. The quote rate shall include all taxes, duties, statutory obligations and safety code compliance as per PMC.

-

-

-

... More
Quote rate for complete system as mentioned above under (2.10.6)

1551

-

-

... More
Aluminium Z Louvers Design Wind Pressure : 1.55kPa Proof Wind Load : 2.32kPa

-

-

-

... More
Design, fabrication, supply, installation, testing, protection, cleaning & handover of Aluminium Louvers system custom designed to withstand the design wind pressure confirming to IS -875 part III. (The system must pass the proof test at 1.5 times design wind pressure without any failure).

-

-

-

... More
Aluminum Louvers shall be made out of "Z" shape louvers spaced at equivalent distance support to Aluminium grid work. Louvers profile shall be fixed on the 2.5mm thick Al angle to form a frame. The louver frame is supported on the aluminium grid mullions with necessary fasteners in SS 316 & MS / Aluminium alloy brackets with provision to accommoadate movement at all floor levels. The bracketing system with Aluminium Alloy of 6005 T5 / MS HDG with built in serration & serrated washers.

-

-

-

... More
Flasing / Trim / Floor Closure at Parapet level, floor level, beam bottom level and required flashings shall be provided continuously with required GI / Aluminium sheet. Internal & External concelled Flashings shall be 1.0mm thk GI sheet. External exposed flashing shall be 3mm thk. Aluminium sheet with PVDF coated matching with external Aluminium profiles. Internal exposed flashing shall be 2mm thk. Aluminium sheet with powder coated matching with internal aluminium profiles.

-

-

-

... More
The extruded aluminium sections of Alloy 6063 T6 & tolerances confirming to DIN / EN standard from approved extruder. The structural profiles shall have minimum 2.5mm wall thickness. All the internal visible & all externally visible surfaces shall have Super Durable Powder coating finish with minimum 60-80 micron confirming to AAMA 2604. External fins shall be PVDF coating with minimum coating thickness of 30-35microns confirming to AAMA 2605. The non visible aluminium surfaces shall have minimum chromatizing treatment.

-

-

-

... More
All Material Make / Vendor list / Supplier list shall be as per tender specification. Acceptance of equivalent makes is subject to prior approval from PMC/Employert.

-

-

-

... More
All shade approval shall be as per PMC/EmployerApproval.

-

-

-

... More
Aluminium's stress utilization, MS utilization & anchors utilization shall not exceeding 90%.

-

-

-

... More
The quote rate shall include all design, engineering & shop drawing approval from architect & consultant. The quote rate shall include all Taxes, duties, statutory obligations and safety code compliance as per PMC.

-

-

-

... More
Quote rate for complete system as mentioned above under 2.10.8

104

-

-

... More
Glass Canopy with Spider Fittings Design Wind Pressure : 1.20kPa Proof Wind Load : 1.80kPa

-

-

-

... More
Design, fabrication, supply, installation, testing, protection, cleaning & handover of Glass canopy with spider glazing system custom designed to withstand the design wind pressure confirming to IS -875 part III. (The system must pass the proof test at 1.5 times design wind pressure without any failure) with weather sealants, backer rod, Bracketing system with MS hot dip galvanized / Aluminium Alloy of 6005 T5 brackets designed to accommodate three dimensional movements with serrated plate and serrated washers, SS 316 grade fasteners & Anchor fasteners, nylon separators to prevent bi-metallic contacts, all complete required to perform as per specification and drawing in conjunction with BOQ.

-

-

-

... More
The stainless steel spider system of Grade 316, supported on MS structure. All the weather sealants shall be non staining of approved make, stainless steel spider system of grade 316 with Articulated bolt assembly, with SS 316 grade fasteners and anchor bolts of approved make, Teflon/ nylon bushes & separators to prevent bi-metallic contacts, all in complete required to perform as per specification and drawing in conjunction with BOQ.

-

-

-

... More
Design, Fabrication, Supply and install required structural steel frame work in line with design drawings for WT 07 made out of MS pipe sections / I Beams / Channels / Plates of approved make make of first quality confirming to IS standard. The steel design shall accommodate thermal stresses resulting from thermal expansion due to surface temperatures. The steel structure shall be finish with the following, i. Surface Preparation – Blast cleaned to Sa 2.5 confirming to BS EN ISO 8501-1 ii. Primer : Zinc Rich Epoxy 75 micron iii. Barrier : Epoxy Mio 125 micron iv. Finish : Polyurethane – 50 Micron (Only for exposed steel)

-

-

-

... More
All Material Make / Vendor list / Supplier list shall be as per tender specification. Acceptance of equivalent makes is subject to prior approval from PMC/Employert.

-

-

-

... More
All shade approval shall be as per PMC/EmployerApproval.

-

-

-

... More
Aluminium's stress utilization, MS utilization & anchors utilization shall not exceeding 90%.

-

-

-

... More
The quote rate shall include all design, engineering & shop drawing approval from architect & consultant. The quote rate shall include all Taxes, duties, statutory obligations and safety code compliance as per PMC.

-

-

-

... More
Glass Canopy system with gutter system Quote rate for complete system as mentioned above under 2.10.9

165

-

-

... More
Canopy Glass: 15.52mm Laminated glass 8mm clear FT with Heat Soak Tested + 1.52mm SGP + 6mm clear FT with Heat Soak Tested

165

-

-

... More
MS Tonnage Design, Fabrication, Supply and install required structural steel frame work in line with design drawings for made out of MS pipe sections / I Beams / Channels / Plates of approved make make of first quality confirming to IS standard. The steel design shall accommodate thermal stresses resulting from thermal expansion due to surface temperatures. The steel structure shall be finish with the following, i. Surface Preparation – Blast cleaned to Sa 2.5 confirming to BS EN ISO 8501-1 ii. Primer : Zinc Rich Epoxy 75 micron iii. Barrier : Epoxy Mio 125 micron iv. Finish : Polyurethane – 50 Micron (Only for exposed steel)

4

-

-

... More
3mm thick solid aluminium sheet cladding Quote extra over on item ((2.10.9 a) ) for providing & fixing 3mm thick solid alum sheet enclosure beneath the canopy glass. Prefabricated grid mullions are fixed on to MS structure with SS 316 nut-bolts as recommended by approved supplier to support given design loads. The brackets shall have provision movement to accommodate the manufacturing tolerances +/- 20mm plumb incase of steel structure. Use of aluminium brackets with serration and serrated washers to prevent wind direction movement after final position. Use of Hot Dipped galvanized brackets with serrations and serrated washers on to Steel structures.

112

-

-

... More
U Channel Glazing at Security Cabin Design Wind Pressure : 1.20kPa Proof Wind Load : 1.80kPa

-

-

-

... More
Design, fabrication, supply, installation, testing, protection, cleaning & handover of U Channel Glazing system designed inline with the architectural intent. The glass is held all around by mechanically from top and bottom with U Channel & structural silicon. Glass to glass groove to be sealed with DowSil clear silicon.

-

-

-

... More
The extruded aluminium sections of Alloy 6063 T6 & tolerances confirming to DIN / EN standard from approved extruder. The structural profiles shall have minimum 2.5mm wall thickness at mechanical engagement points. All the internal & external visible surfaces shall have high Durability (Akzonobel) / Super durable (Jotun) Powder coating of 60 - 80 micron confirming to AAMA 2604. The non visible aluminium surfaces shall have minimum chromatizing treatment.

-

-

-

... More
SS316 Anchors to be designed as per cracked concrete condition.

-

-

-

... More
All Material Make / Vendor list / Supplier list shall be as per Annexure 1. Acceptance of equivalent makes is subject to prior approval from PMC/Employert.

-

-

-

... More
All shade approval shall be as per PMC/EmployerApproval.

-

-

-

... More
The system shall demonstrate performance for air seal / water seal / structural /seismic requirement.

-

-

-

... More
Aluminium's stress utilization, MS utilization & anchors utilization shall not exceeding 90%.

-

-

-

... More
The quote rate shall include all design, engineering & shop drawing approval from architect & consultant. The quote rate shall include all taxes, duties, statutory obligations and safety code compliance as per PMC.

-

-

-

... More
U Channel System Quote rate for complete system as mentioned above under 2.10.10

56

-

-

... More
Vision Glass : Extra over (2.10.10 a) Quote extra over on item (1.10.10 a) for providing and fixing 13.52mm thick Laminated Glass 6mm Clear HS + 1.52mm PVB + 6mm Clear HS

56

-

-

... More
Side Hung operable Window at Security Block Design Wind Pressure : 1.20kPa Proof Wind Load : 1.80kPa

-

-

-

... More
Providing & fixing the Side Hung vent,. System shall have Euro grooves for the compatibility of European accessories. Cremon handle with multi point locking to ensure air tight sealing . Butt hinges / concealed butt hinges,stay arm with 30o & 90o , Microwave cured EPDM gaskets to acomodate glass thickness as per structural requirement, weather sealants, SS 316 grade screws of approved make, all in complete required to perform as per specification and drawing in conjunction with BOQ. Some locking points to be typhoon locks. Location of the operable vent shall be inline with tender drawing.

-

-

-

... More
Microwave cured EPDM gaskets to accomodate glass thickness as per structural requirement, weather sealants, SS 316 grade screws of approved make, all in complete required to perform as per specification and drawing in conjunction with BOQ. Complete system shall be warranteed for minimum 10 yrs against design & workmanship defects.

-

-

-

... More
The extruded aluminium sections of Alloy 6063 T6 & tolerances confirming to DIN / EN standard from approved extruder. The structural profiles shall have minimum 2.5mm wall thickness at mechanical engagement points. All the internal & external visible surfaces shall have high Durability (Akzonobel) / Super durable (Jotun) Powder coating of 60 - 80 micron confirming to AAMA 2604. The non visible aluminium surfaces shall have minimum chromatizing treatment.

-

-

-

... More
All Material Make / Vendor list / Supplier list shall be as per tender specification. Acceptance of equivalent makes is subject to prior approval from PMC/Employert.

-

-

-

... More
All shade approval shall be as per PMC/EmployerApproval.

-

-

-

... More
The system shall demonstrate performance for air seal / water seal / structural requirement.

-

-

-

... More
Aluminium's stress utilization, MS utilization & anchors utilization shall not exceeding 90%.

-

-

-

... More
The quote rate shall include all design, engineering & shop drawing approval from architect & consultant. The quote rate shall include all Taxes, duties, statutory obligations and safety code compliance as per PMC.

-

-

-

... More
Side Hung Window System Quote rate for complete system as mentioned above under 2.10.11 including all hardwares & accessories

15

-

-

... More
Vision Glass : Extra over 2.10.11 a)(side hung window) Quote extra over on item (2.10.11 a) ) for providing and fixing 6mm Clear HS Glass

15

-

-

... More
Aluminium Framed Door Design Wind Pressure : 1.20kPa Proof Wind Load : 1.80kPa Design, fabrication, supply, installation, testing, protection, cleaning & handover of single leaf aluminium framed door door opening outward / inward (as per tender drawings) custom designed to withstand the design wind pressure. The system shall have two barrier gasket system for weather sealing & provision for aluminium thrash hold at bottom. The profile system shall be of minimum 2.5mm thickness. Door shutter shall have crimped corner at top and SS tie rod at bottom for rigid connection. The system shall have hydraulic door closure mounted on the profiles, three leaf projected type hinges of approved make, Microwave cured EPDM gaskets .Door shutter profile to accommodate the 12mm clear FT glass, weather sealants, SS 316 grade screws and fasteners of approved make, all in complete required to perform as per specification and drawing in conjunction with BOQ. The extruded aluminium sections of Alloy 6063 T6 & tolerances confirming to DIN / EN standard from approved extruder. The structural profiles shall have minimum 2.5mm wall thickness at mechanical engagement points. All the internal & external visible surfaces shall have high Durability (Akzonobel) / Super durable (Jotun) Powder coating of 60 - 80 micron confirming to AAMA 2604. The non visible aluminium surfaces shall have minimum chromatizing treatment.

-

-

-

... More
Quote rate for complete system as mentioned above with fittings and door closure including 12mm clear FT - Single Shutter (Size : 1000mm X 2530mm)

4

-

-

... More
Quote rate for complete system as mentioned above with fittings and door closure including 12mm clear FT - Single Shutter (Size : 1200mm X 2530mm)

1

-

-

... More
Single Shutter Sliding Door Design Wind Pressure : 1.20kPa Proof Wind Load : 1.80kPa

-

-

-

... More
Design, fabrication, supply, installation, testing, protection, cleaning & handover of Sliding Doors / Windows system custom designed to withstand the design wind pressure confirming to IS -875 part III. (The system must pass the proof test at 1.5 times design wind pressure without any failure). The system shall have drainage gutter profile at bottom track with the possibility of drain container, wool pile with silent film for weather protection and complete air seal. The shutter engagement shall be minimum of 12mm at top and bottom track to ensure stability under deflection of vertical mullions. The track profile to be designed to ensure smooth movement of the shutter with the rollers of needle bearings or ball bearing.

-

-

-

... More
The system shall be designed to accomodate European accessories with Heavy duty roller assembly considering the weight of the shutters and flush type lock with manual operation. Microwave cured EPDM gaskets to accomodate glass thickness as per structural requirement, weather sealants, top & bottom shutter guides, anticapillary at interlock junction for proper sealaing, SS 316 grade screws of approved make, all in complete required to perform as per specification and drawing in conjunction with BOQ. Complete system shall be warranteed for minimum 10 yrs against design & workmanship defects.

-

-

-

... More
The extruded aluminium sections of Alloy 6063 T6 & tolerances confirming to DIN / EN standard from approved extruder. The structural profiles shall have minimum 2.5mm wall thickness at mechanical engagement points. All the internal & external visible surfaces shall have high Durability (Akzonobel) / Super durable (Jotun) Powder coating of 60 - 80 micron confirming to AAMA 2604. The non visible aluminium surfaces shall have minimum chromatizing treatment.

-

-

-

... More
All Material Make / Vendor list / Supplier list shall be as per Annexure 1. Acceptance of equivalent makes is subject to prior approval from PMC/Employert.

-

-

-

... More
All shade approval shall be as per PMC/EmployerApproval.

-

-

-

... More
The system shall demonstrate performance for air seal / water seal / structural /seismic requirement.

-

-

-

... More
The quote rate shall include all design, engineering & shop drawing approval from architect & consultant. The quote rate shall include all taxes, duties, statutory obligations and safety code compliance as per PMC.

-

-

-

... More
Quote rate for complete system as mentioned above 1225mm (W) x 2530mm (H) = 2 Nos.

7

-

-

... More
Aluminium Baffles Design Wind Pressure : 1.20kPa Proof Wind Load : 1.80kPa

-

-

-

... More
Design, fabrication, supply, installation, testing, protection, cleaning & handover of Aluminium Box Profile Baffle Ceiling system custom designed to withstand the design wind pressure which is confirming to IS -875 part III. (The system must pass the proof test at 1.5 times design wind pressure without any failure).

-

-

-

... More
Aluminum system shall be of HunterDouglas product V100 or equivalent at C/C spacing of 100/150/200mm as per Architect's approval. The louver frame is supported on the MS structural frame work with necessary fasteners in SS 316 & MS brackets with provision to accommoadate movement at all floor levels.

-

-

-

... More
The extruded aluminium sections of Alloy 6063 T6 & tolerances confirming to DIN / EN standard from approved extruder. All the visible surfaces shall have Superdurable powder coating of 60 - 80 micron confirming to AAMA 2604. The non visible aluminium surfaces shall have minimum chromatizing treatment.

-

-

-

... More
All Material Make / Vendor list / Supplier list shall be as per tender specification. Acceptance of equivalent makes is subject to prior approval from Client / PMC / Architect

-

-

-

... More
All shade approval shall be as per Client / PMC / Architect's approval.

-

-

-

... More
The quote rate shall include all design, engineering & shop drawing approval from Client / PMC / Architect . The quote rate shall include all Taxes, duties, statutory obligations and safety code compliance as per PMC / Client.

-

-

-

... More
Bafffle System Quote rate for complete system as mentioned above

236

-

-

... More
MS Tonnage (Considered 20 kg/sqm) : Suspended supports for baffles Design, Fabrication, Supply and install required structural steel frame work in line with design drawings for made out of MS pipe sections / I Beams / Channels / Plates of approved make make of first quality confirming to IS standard. The steel design shall accommodate thermal stresses resulting from thermal expansion due to surface temperatures. The steel structure shall be finish with the following, i. Surface Preparation – Blast cleaned to Sa 2.5 confirming to BS EN ISO 8501-1 ii. Primer : Zinc Rich Epoxy 75 micron iii. Barrier : Epoxy Mio 125 micron iv. Finish : Polyurethane – 50 Micron (Only for exposed steel)

5

-

-

... More
ACP soffit cladding FR class B (At First Floor Level) Design Wind Pressure : 1.20kPa Proof Wind Load : 1.80kPa

-

-

-

... More
Design, Fabrication, Supply, installation, Testing , protection, cleaning & handover of Aluminium composite cladding of approved make in solid or metallic colours as per architect's approval Using grid work of prefabricated aluminium extruded sections to with stand the design wind pressure confirming to IS -875 part III. (The system must pass the proof test at 1.5 times design wind pressure). The fastening brackets of Aluminium alloy 6005 T5 / MS with HDG with serrations and serrated washers to arrest the wind load movement, fasteners and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing in conjunction with BOQ.

-

-

-

... More
The 4mm thk ACP consists of 0.5mm outer skin of Aluminium with Lumiflon based fluorocarbon paint or kynar 500 based PVDF paint confirming to AAMA 2605 + 3mm FR Grade mineral core material (Fr Grade Class B as per EN 13501) + 0.5 mm aluminium skin with service coat. The panel shall be designed for 15mm groove in horizontal & 15mm groove in verticals with close joint system. Vertical & Horizontal groove shall be filled by non staining high performance weather sealant. ACP panel shall have subframe all around panel and aluminium stiffner profile as per structural requirments.

-

-

-

... More
Prefabricated grid mullions are fixed on to the RCC and concrete walls with SS 316 anchor bolts as recommended by approved supplier to support given desing loads. The brackets shall have provision movement to accommodate the construction tolerances with + 35mm plumb in case of RCC structure and + 20mm plumb incase of steel structure . Use of aluminium brackets with serration and serrated washers to prevent wind direction movement after final postion. Use of Hot Dipped galvanised brackets with serrations and serrated washers on to Steel structures.

-

-

-

... More
The design shall accommodate the building movements, thermal expansion and seismic movements. Also shall accommodate thermal expansion resulting from surface temperature of 80-90 deg cel on ACP outer skin without creating any additional stress.

-

-

-

... More
The extruded aluminium sections of Alloy 6063 T5 / T6 & tolerances confirming to DIN / EN standard from approved extruder. The structural profiles shall have minimum 2.5mm wall thickness. Externally visible surfaces shall be PVDF coating with minimum coating thickness of 30-35microns confirming to AAMA 2605 with min 30 years warantee. The non visible aluminium surfaces shall have minimum chromatizing treatment. Complete system shall be warranteed for minimum 10 yrs against design & workmanship defects.

-

-

-

... More
All Material Make / Vendor list / Supplier list shall be as per tender specification. (Annexure 1)

-

-

-

... More
All shade approval shall be as per Architect's Approval.

-

-

-

... More
The system shall demonstrate performance for air seal / water seal / structural /seismic requirement. Onsite test for workmanship verification shall be carried out in stages for water penetration hose test as per AAMA 501.2 at minimum 6 locations.

-

-

-

... More
The quote rate shall include all design, engineering & shop drawing approval from architect & consultant. The quote rate shall include all Taxes, duties, statutory obligations and safety code compliance as per PMC.

-

-

-

... More
ACP Cladding with close joint system as mentioned above under (2.10.15)

-

-

-

... More
Quote rate for complete system as mentioned above under 2.10.15 including 4mm thk. Class B FR grade ACP

985

-

-

... More
Performance Mockup Test at NABL Accredited laboratory of Unitized Glazing System 3bay x 2 floor height • Pre-Load for 50% of +ve design wind pressure - 1500 Pa • Air Infiltration test –300 Pa (As per ASTM E 283) • Static water test –450 Pa (As per ASTM E 331) • Dynamic water test –450 Pa (As per AAMA 501.1) • Wind load serviceability test 100%, +ve design wind pressure –2000 Pa (As per ASTM E 330) • Wind load serviceability test 100%, -ve design wind pressure –2000 Pa (As per ASTM E 330) • Repeat air Infiltration test –300 Pa (As per ASTM E 283) • Repeat static water test –450 Pa (As per ASTM E 331) • Proof load test 150% +ve design wind load –2250 Pa (As per ASTM E 330) • Seismic rack test

1

-

-

... More
Onsite Water test as per AAMA 501 by NABL Accredited Laboratory

-

-

-

... More
At Unitized Glazing Area: 3 Locations

1

-

-

... More
At Conventional Cap Curtain Wall Glazing Area (Entrance Glazing) : 2 Location

1

-

-

... More
At Conventional Capped Curtain Wall Glazing Area (Cafeteria) : 1 Location

1

-

-

... More
BMU Type 01- Floor Mounted BMU On Twin Track

-

-

-

... More
Design, manufacture, supply, transportation and installation ofFloor Mounted BMU On Twin Track (Type-1) With Luffing Jib (Max Outreach = 5.7m & Height 2.8m) integrated with Glass Replacement unit capacity-200kg, double suspension cradle, Galvanized steel track including all necessary fixing arrangement as per requirement complete as directed by project manager/As per site condition. The trolley rigid base frame has four traversing wheels for a safe load distribution. Each front wheel is equipped with an electrical driven geared motor. Limit switches control and stop the movement when the path end is reached. The machine has a base frame mounted on wheel assemblies designed to run on single L-Angle guide rail fixed to the parapet wall. (Note :- The Contractor must provide details of structural calculations and also provide shop drawings and all details - clearly indicating all dimensions, fixing details etc. for approval. Vendor visit the site and review the drawings before quote, nothing extra shall be paid. ) BMU should have following technical Spec. 1. Safe working load 240kg. 2. Glass replacement unit capacity 200kg , permanently fixed to BMU. 3. Main Hoisting system- Multilayer drum winch (No friction type/Traction type). 4. Should have four individual wire rope (2 for working,2 for safety). 5. All Steel parts to be Galvanized for minimum 100 microns. 6. Restraint autostop function and indicator to be provided in the cradle. 7. Wire rope make to minimum Brugg/Gustav Wolf of core conductor. Not less than 7mm,Length accoridng to Building height requirement 8. Lufing Jib and mast with all safety values. 9.Double Suspension Cradle Articulated Cradle

-

-

-

... More
Floor Mounted BMU On Twin Track (Outreach 5.7 Meter )

1

-

-

... More
Glass Replacement Unit capacity 200kg

1

-

-

... More
Double Suspension Articulated Cradle

1

-

-

... More
Twin Track Hot dip Galvanized

539

-

-

... More
Base Plates Grade E-350 C/C-2.0 M

284

-

-

... More
SS 316 Chemical Anchors fixed with Hilti/Fischer Chemical

1135

-

-

... More
SS 316 grade Nut-Bolt

873

-

-

... More
BMU Type 04- Restraining System

-

-

-

... More
Design, manufacture, Supply of S.S. 316 grade Restraining Socket ( As per drawing attach) - Supply Only - Excluding Fixinging Accessories. Fixing will be done by fabricator. To comply with BS EN 1808 standards, external use suspended façade access equipment suspension ropes must be restrained to the façade. The following statement taken from BS EN 1808 standards outline the requirement of the façade restraint system: 1. The lowest restraint point shall not be more than 40 meters above the lowest working level. 2. The distance between restraints above 40 meters shall not exceed 20 meters. 3. The restraint lanyards shall be attachable & detachable by an operator on the platform in a safe manner.

130

-

-

... More
SS 316 Restraining Pins/Lanyard

2

-

-

... More
9m long Aluminum telescopic water fed tucker pole

1

-

-

... More
Mobile Aluminum Scaffolding - ground floor glazing

1

-

-

... More
HARD LANDSCAPE WORKS

-

-

-

-

-

-

... More
Supplying and fixing of pre-cast kerb stone of size 450x300x150mm made in CC 1:3:6 (One of cement, three of sand and six of hard broken stone jelly) using 20mm size hard broken stone jelly including the cost of Kerb stone moulding, laying, curing, transporting, pointing and as directed by the Project Officer.

2177

-

-

... More
Pavers

-

-

-

... More
Supplying and laying of Rubber Moulded Hydraulic pressed Interlocking Paver Block Stone 83 mm thk, M-40 Grade of Grey Colour; Over a base layer of crushed stone sandfilling incl. Cost of materials laying and Labour charges etc.,

350

-

-

... More
Supplying and laying of Rubber Moulded Hydraulic pressed Interlocking Paver Block Stone 83 mm thk, M-40 Grade of black Colour; Over a base layer of crushed stone sandfilling incl. Cost of materials laying and Labour charges etc.,

1537

-

-

... More
Supplying and laying of Rubber Moulded Hydraulic pressed Interlocking Paver Block Stone 63 mm thk, M-30 Grade Over a base layer of crushed stone sandfilling incl. Cost of materials laying and Labour charges etc.,

6577

-

-

... More
Supplying and laying of Rubber Moulded Hydraulic pressed Square Paver Block Stone 83 mm thk, M-40 Grade of Light Grey Colour; Over a base layer of crushed stone sandfilling incl. Cost of materials laying and Labour charges etc.,

213

-

-

... More
Supplying and laying of Rubber Moulded Hydraulic pressed Square Paver Block Stone 83 mm thk, M-40 Grade of Dark Grey Colour; Over a base layer of crushed stone sandfilling incl. Cost of materials laying and Labour charges etc.,

115

-

-

... More
Supplying and laying of Rubber Moulded Hydraulic pressed square Paver Block Stone 83 mm thk, M-40 Grade of Black Colour; Over a base layer of crushed stone sandfilling incl. Cost of materials laying and Labour charges etc.,

471

-

-

... More
Turf paver

-

-

-

... More
Providing and laying 500x500x40mm thick Turf paver (Turfpave XD)on 150mm thick sub grade of compacted bed of 20mm thick nominal size stone aggregate and base course and filling with 150mm thick jamuna sand, including spreading, well ramming, consolidating and finishing smooth etc. all complete as per direction of Engineer-in-charge.

1089

-

-

... More
Tactile paving

-

-

-

... More
Supplying and laying of Tactile Paver Block Stone 15 mm thk. Over a base layer of crushed stone sandfilling incl. Cost of materials laying and Labour charges etc.,

28

-

-

... More
LIGHTING

-

-

-

... More
Street Light – Type 1. Supply and installation of - Swaged pole of 140mm diameter & tapered to 115mm where the pole is welded with V groove technology & finished with all weather PU paint on zinc primer coat. Complete with control gear box with loop in loop out terminal & MCB. Single arm with height of 9 metres from base. Including foundation bolts & nuts. Body colour as per PMC/ Employer selection. IP 65 grade street light luminaire made of die cast aluminium with 100 lumens per watt, CRI 80, system wattage of 180 watts & street light distribution. Body colour & LED colour temperature as per PMC/ Employer selection.

-

-

-

... More
Lighting Pole (Ht.9000mm, Single Arm, Pole Size : Ø114.3 / Ø139.7)

11

-

-

... More
Foundation Bolt

11

-

-

... More
Luminaire - 180W LED

11

-

-

... More
Street Light – Type 2. Supply and installation of – Swaged pole of 140mm diameter & tapered to 115mm where the pole is welded with V groove technology & finished with all weather PU paint on zinc primer coat. Complete with control gear box with loop in loop out terminal & MCB. Double arm with height of 9 metres from base. Including foundation bolts & nuts. Body colour as per PMC/ Employer selection. IP 65 grade street light luminaire made of die cast aluminium with 100 lumens per watt, CRI 80, system wattage of 180 watts & street light distribution. Body colour & LED colour temperature as per PMC/ Employer selection.

-

-

-

... More
Lighting Pole (Ht.9000mm, Double Arm, Pole Size : Ø114.3 / Ø139.7)

3

-

-

... More
Foundation Bolt

3

-

-

... More
Luminaire - 180W LED

6

-

-

... More
Post Top Lantern - Supply and installation of 100mm square pole where the pole is welded with V groove technology & finished with all weather PU paint on zinc primer coat. Complete with control gear box with loop in loop out terminal & MCB. 24/30 watts built in LED luminaire in single arm with height of 3 metres from base. Including foundation bolts & nuts. IP 65 grade street light luminaire made of die cast aluminium with 80 lumens per watt, CRI 80, system wattage of 30 watts & street light distribution. Body colour & LED colour temperature as per PMC/ Employer selection.

-

-

-

... More
Luminaire, 24W LED

113

-

-

... More
Lighting Pole – (Ht.3000mm, Pole Size : 100mm square)

113

-

-

... More
Foundation Bolt

113

-

-

... More
Bollard - Supply and installation of - 1000mm height bollard luminaire for outdoor garden use with minimum 16 watts LED, IP-65 & aesthetically designed for ambient illumination & highlighting of pathway/plants/shrubs with Body colour & LED colour temperature as per PMC/ Employer selection.

-

-

-

... More
Bollard [Dimension : 121mm Square x 1000mm ht], 16W LED

136

-

-

... More
Landscape Focus Light - Supply and installation of - Tree/plant/landscape lights to create and form an illumination for the area & illuminate the greenery with low powered lamp fittings made of aluminium. 3w LED uplight, IP-65. Body colour & LED colour temperature as per PMC/ Employer selection.

-

-

-

... More
Light fixture [Dimension : 83 x 116 x 110mm] 3W LED

3

-

-

... More
IRRIGATION

-

-

-

... More
Manual Irrigation Works

-

-

-

... More
Description

-

-

-

... More
Pipes Work: Supply, laying & commissioning in position PVC pipe conforming to IS:4985:2000 and suitable for the respective working pressures without all fittings and accessories e.g. couplings, tees, bends, reducers, screwed adapters, flanged tail pieces etc., complete.

-

-

-

... More
uPVC Pipe 63 mm dia / 6 Kg / sq. Cm.

120

-

-

... More
uPVC Pipe 40 mm dia / 6 Kg / sq. Cm.

762

-

-

... More
uPVC Pipe 20 mm dia / 10 Kg / sq. Cm.

30

-

-

... More
Specials like Tee, Elbow,Reducr, Bush, Solvent, MTA,FTA,Union,Tailpiece etc., @ 30 % of uPVC Pipe value

1

-

-

... More
Earth work excavation and refilling 300x450mm

1325

-

-

... More
Core cutting in concrete slab/brick wall for pipe routing Up 63 to 110 mm dia

5

-

-

... More
DRIP & ACCESSORIES

-

-

-

... More
Supply and installation of flexible,kink resistant 16mm inline tubing with pressure compensating, self flushing mechanism , Flat emitter and resistance to UV damage, algae growth brown in colour, Longer lateral run lengh with flow rate 2.3lph to 3.4 lph, pressure rating 0.58 to 4.1 bar wall thickness 1.2mm etc., complete.

10400

-

-

... More
Supply and installation of 12- Gauge Galvanized Steal Rod Comes Pre -Bent to Staple Distribution Tubing , XF Drip Line or XBS Tubing to Finished Grade. Notched Sides. Corrosion -Resistant of TIE DOWN STAKE TDSO50BEND

5130

-

-

... More
Supply and installation of High Quality Barbs Grab Tubing for a Secure Fit. Unique Barb Design to Reduce Insertion Force. Non - Obtrusive Brown Colored Fittings of 17mm BARBX BARB TEE , Elbow & Coupler.

100

-

-

... More
Supply and installation of High Quality Barbs Grab Tubing for a Secure Fit. Unique Barb Design to Reduce Insertion Force. Non - Obtrusive Brown Colored Fittings of 17mm BARBX 3/4 " / 1/2" MPT ADAPT

300

-

-

... More
Supply and installation of 17mm End cap S Type for dripline closure at the end of the dripline

300

-

-

... More
VALVES & ACCESSORIES

-

-

-

... More
Supply and installation of 63 mm dia PVC Single Union Ball Valve,security pivot to maintain lever in space,double water tight joint,direct injection stem,Stem O-Ring, non mechanical ,ball Seals with backing seals and with a base which permits maximum penetration into the valve with pressure rating PN 10 etc., complete.

11

-

-

... More
Supply and installation of a double acting air and vaccum release 2 " Air release valve . The Air release valve shall be capable of both releasing and admitting air from and into the line. The working pressure shall be 5 bar.

3

-

-

... More
Supply and installation 6"Round box with greenlid and corrugated structure with unique shovel access slot and bolt hole knockout & Having Dimensions @ Top Opening :6 1/8" Dia & Bottom Opening 8 5/8" Dia etc., complete, as per the instructions of PMC\Employer

19

-

-

... More
Supply and installation of 18'' Jumbo Rectangular Standard Valve Box with greenlid and corrugated structure with unique shovel access slot and bolt hole knockout & having Dimensions @ Top Opening:18 1/4" L X 13" W & bottom opening :21 1/4" L X 15 15/16"W X 12" H PVB/VB

11

-

-

... More
Supply and installation of 3/4" Quick coupling valve made up of solid brass with locking cover corrosion resistant and stainless steel spring etc., complete.

17

-

-

... More
Supply and installation of 3/4 " Sweivel Elbow with Key threads into top of QCV to provide water access etc., complete.

6

-

-

... More
Supply and installation of a double acting air and vaccum release 1/2 " . The Air release valve shall be capable of both releasing and admitting air from and into the line. The working pressure shall be 5 bar. Only for Drip Irrigation etc., complete.

11

-

-

... More
Supply and installation of 63mm / 40mm dia self-closing flushing valves that are installed at the end of the irrigation line for effecting flushing of the line at the beginning of every irrigation cycle, thus avoiding the clogging of the emitters /sprinklers through removal of particles, sediments and other impurities from the water. etc., complete.

16

-

-

... More
PUMP & ACCESSORIES , FILTERATION

-

-

-

... More
Supply and installation of control panel suitable for pumpset having panel box made of CRCA sheet of 2 mm thickness and fixed alongwith following accessories DOL starter (L&T make),start / stop push buttons (L&T make), Ammeter (AE make), Single phase preventor (Minilec make), Voltmeter (AE make) , Indicating lamps (L & T make), MCB (L & T make), Dry level guard sensor (Minilec make) etc., complete. Both pump in 1 panel.

1

-

-

... More
Supply and installation of 3" Twin Disc Filter with capacity 50 M ³ / Hr having an suitable inlet connections , to create a helical effect in the incoming water ,spinning particulate in suspension away from the filtering element and so minimizing cleanings frequency ,1/2" outlet for flushing at bottom of filter & maximum working pressure of 10 Bars etc.

1

-

-

... More
Supply and installation of 3'' Butterfly Valve VAN Stone flange & Tail Piece in mainline for bypass and flow diversion of approved quality with pressure rating of PN 10 etc., complete.

2

-

-

... More
Supply and installation of 3 '' Dual plate chuck valve with necessary fittings & Accessories like flanges,nut,bolt,plate washer,to prevent back flow have flap type or spring type with pressure rating of PN 10 etc., complete,

1

-

-

... More
Supply and installation of Pressure release valve 2" with pressure setting from 0 to 7 Bar etc., complete, as per the instructions of PMC\Employer

1

-

-

... More
Automation Equipments

-

-

-

... More
Supply and installation of Direct burial 14 Awg x 2 Maxi cable with PVC insulated UL stndard 493 with impregnated polyethene jacket and soft annealed tin coated copper confirming to ASTM B-33 for two way communication between decoder controller and decoders complete

750

-

-

... More
Supply and installation,Fixing & Commissioning of PVC pipe 32mm-10 kg/cm² including fittings and accessories

750

-

-

... More
Supply and installation of decoder control system outdoor rated, UV resistant,wall mount case, to support sensor decoder,turf decoders and line surgeprotectors (LSP) with options of program BACK UP AND RESTORE , cycle +soak,Raindelay,ET managers ,weather station, controlling upto 5 master valve(5water source)with diagnostic feature in wire shorttest ,voltage test at stations,ping test and with option to upgradable to IQ central control including , standard accessories complete ESP- LXD.

1

-

-

... More
Supply and installation of 2.0 " Solenoid globe angle inlet Valves with fabric reinforced Nitrile diaphram Material and rugged PVC durable glass -filled nylon construction ,compatible with and slow closing to prevent water hammer,pressure rating upto 10.4 KSC and maximum flow of 150GPM ,max water temp. upto 42degree centigrade, with 24AC solenoid,current rating 0.41A @60Hz,coil resistance 30ohm with provision to attach PRS-Dial PGA Pressure Regulation Optional PRS-D

11

-

-

... More
Supply,Fixing & commissioning of PRS-DIAL to Maintain constant outlet pressure between 1.04 to6.9 KSC

11

-

-

... More
Supply,Fixing & Commissioning of Field Decodertor support 1 station ,fully water proof encapsulation,power draw 0.5mA at idle and 18mA at active ,working range 0 deg to 50 degree centigrade as per specifications and with different station capacities as given below Field Decoder 1 station FD101

12

-

-

... More
Supply,Fixing & commisioning of Line Surge Protection device as required with copper grounding rod, clamps, charcoal and all requisite accessories complete LSP

3

-

-

... More
Supply,Fixing & commissioning of direct bury -on wire connector with strain relief ,UL486 D certified ,with waterproof silicon sealant ,fits wire from 22ga to6 ga as per specifications complete DBRY

60

-

-

... More
Supply and installation of automatic rain shut off device ,latching hinge with multiple rainfall settings 5mm to 20mm UL CUL listed and CE approved complete RSD BEX

1

-

-

... More
Supply and installation of Pump relay 24 AC PLA relay with encloser.

1

-

-

... More
SOFT LANDSCAPE WORKS

-

-

-

-

-

-

... More
Supply & stacking of red earth at site to the departmental guage for pre-measurements which is of light textured, crystalline, porous and friable and not of generally acidic or neutral but not of alkaline and should be fertile, including seignior age charges, cost of transportation, loading, unloading, stacking and inclusive of all taxes etc., complete. .

618

-

-

... More
Supply of well decomposed Farm yard Manure in a powdery form, devoid of soil sand, stones, plastics and other materials, highly nutrient and which supports plant growth.

618

-

-

... More
Supply and stacking of pit sand / earth filling sand at site to the departmental gauge for pre- measurements obtained from sand deposits and should clean without solid particles

309

-

-

... More
"Mixing charges of Red soil, manure and pit sand uniformly (2:2:1) for Preparation of soil mixture (excluding material cost)"

1545

-

-

... More
Spreading of red soil, gravel or sand including watering and rolling which hand roller for every 75 mm thickness - including hire charges of roller.

1545

-

-

... More
Filling mixture of Red soil, manure and pit sand in the desired proportion in trenches, flooding with water and leveling (cost of supplyingRed soil, manure and pit sand and mixing excluded).

1545

-

-

... More
PLANTING PIT PREPARATION

-

-

-

... More
Earth work excavation for foundation in all kinds soils in varying depths (Digging of new trenches for hedge / edge planting, digging and removal of excavated earth from site complete)

1378

-

-

... More
SUPPLYING & PLANTING OF PLANTS

-

-

-

... More
Supplying & planting of trees

-

-

-

... More
Supplying and planting at site healthy,disease free and well developed Trees.of the prescribed height and spread as per detail below, supported with casuarina stakes, including cost of transportation, loading and unloading and providing the required intermittent care in the course of transportation and upto plantation. Plants to be supplied in polybag / HDPEbag / earthenpot of of size as mentioned below.

-

-

-

... More
Providing, stacking and planting of Albizzia lebbek of height 150-165 cm. in bag of size 25 cm as per direction of the PMC / Employer

35

-

-

... More
Providing, stacking and planting of Azadirachta indica ( Neem ) of height 120-130cm in big polybag of size 25 cm as per direction of the PMC / Employer

27

-

-

... More
Providing,stacking and planting of Bauhinia blakeana (Kachnar) of height 120-150 cm. in big poly bags of size 25 cm as per direction of the PMC / Employer.

40

-

-

... More
Providing, stacking and planting of Bombax ceiba of height 150-165 cm. in big poly bags of size 25 cm as per direction of the PMC / Employer.

8

-

-

... More
Providing, stacking and planting of Butea frondosa (Flame of Forest) of height 60-75 cm. in big poly bags of size 25 cm as per direction of the PMC / Employer.

19

-

-

... More
Providing,stacking and planting of Cassia fistula (Amaltash) of height 120-135 cm. In big poly bags of size 25 cm as per direction of the PMC / Employer.

14

-

-

... More
Providing,stacking and planting of Erythrina indica of height 150-165 cm. in big polybag of size 25 cm as per direction of the PMC / Employer.

25

-

-

... More
Providing, stacking and planting of Mangifera indica (Mango-grafted ) of height 60-75 cm. in big poly bag of size 25 cm as per direction of the PMC / Employer.

28

-

-

... More
Providing,stacking and planting of Millingtonia hortensis of height 150-165 cm. In big poly bag of size 25 cm as per direction of the PMC / Employer.

33

-

-

... More
Providing,stacking and planting of Mimusops elengi (Maulsri) of height 150-165 cm. In big poly bag of size 25 cm as per direction of the PMC / Employer.

24

-

-

... More
Providing,stacking and planting of Nauclea cadamba (Kadam) of height 150-165 cm. in big poly bag of size 25 cm as per direction of the PMC / Employer.

328

-

-

... More
Providing,stacking and planting of Pongamia glabra (Papri) of height 120-135 cm. In big poly bag of size 25 cm as per direction of the PMC / Employer.

161

-

-

... More
Providing, stacking and planting of Eugenia jambolana (Jamun) of height 150-165 cm. in big poly bags of size 25 cm as per direction of the PMC / Employer.

44

-

-

... More
Providing, stacking and planting of Tamarindus indica (Imli) of height 120-150 cm. In big polybags of size 25 cm as per direction of the PMC / Employer.

45

-

-

... More
Providing,stacking and planting of Terminalia arjuna of height 150-165 cm. in big polybags of size 25 cm as per direction of the PMC / Employer.

44

-

-

... More
Providing,stacking and planting Bismarckia Palm 115 to 180 cm ht., well developed 12 and above good color fresh and healthy leaves in 40 cm Cement Pot as per direction of the PMC / Employer.

2

-

-

... More
Providing,stacking and planting of Plumeria rubra of height 120-150 cm. With 3-4 branches and thick stem in big size HDPE bags as per direction of the PMC / Employer.

3

-

-

... More
"Supplying and Planting of Terminalia Metalica (Terminalia mantalay variegated) ornamental foliage Specimen plant variety of height 105-120 cm in polythene bag of size 16x16 inch including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the PMC / Employer."

20

-

-

... More
`Supplying and Planting of Terminalia Metalica green (Terminalia mantalay green) ornamental foliage Specimen plant variety of height 105-120 cm in polythene bag of size 16x16 inch including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the PMC / Employer.

20

-

-

... More
Supplying & planting of shrubs

-

-

-

... More
Supplying and planting at site healthy,disease free and well developed shrubs of the prescribed height as per detail below including cost of transportation, loading and unloading and providing the required intermittent care in the course of transportation and upto plantation. Plants to be supplied in polybag / HDPEbag / earthen pot of size as mentioned below.

-

-

-

... More
Providing, stacking and planting Acalypha red well developed with fresh & healthy 30 to 45 cm ht. in 20 cm size Earthen Pot/ Plastic Pot as per direction of the PMC / Employer.

2141

-

-

... More
Supplying and Planting of Dypsis lutescens (Areca palm) palm variety of height 180-210 cm in polythene bag of size 16x16 inch including supporting stack of 5 cm dia casurina pole of 10 feet height, including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the PMC / Employer.

20

-

-

... More
Providing, stacking and planting Bougainvillea named Cherry Blossom well developed with fresh & healthy bushy in full bloom 75 to 90 cm ht. in 40 cm Cement Pot as per direction of the PMC / Employer.

646

-

-

... More
Providing, stacking and planting Bougainvillea named Thima well developed with fresh & healthy bushy in full bloom 75 to 90 cm ht. in 40 cm Cement Pot as per direction of the PMC / Employer.

476

-

-

... More
"Supplying and Planting of Euphorbia milli foliage shrub variety of height 30-45 cm in polythene bag of size 6x7 inch including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by thePMC / Employer."

215

-

-

... More
Providing, stacking and planting of Excoecaria bicolor of height 45-60 cm. in earthen pots of size 20 cm as per direction of the PMC / Employer.

1286

-

-

... More
Supplying and Planting of Ficus black ornamental foliage shrub variety of height 30-45 cm in polythene bag of size 6x7 inch including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the PMC / Employer.

123

-

-

... More
Providing, stacking and planting of Ficus reginald well branched, bushy of height 45- 60 cm. in earthen pots of size 25 cm as per direction of the PMC / Employer.

118

-

-

... More
Providing, stacking and planting of Gardenia jasminoides of height 45-60 cm. With 3- 4 branches in earthen pots of size 20 cm as per direction of the PMC / Employer.

568

-

-

... More
"Supplying and Planting of Hemelia pattens foliage shrub variety of height 30-45 cm in polythene bag of size 6x7 inch including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the PMC / Employer."

578

-

-

... More
Providing, stacking and planting of Hibiscus rosasinensis of height 90-105 cm., bushy in big size HDPE bag as per direction of the PMC / Employer.

640

-

-

... More
Providing, stacking and planting of Hibiscus variegated of height 60-75 cm. With healthy variegated foliage in earthen pots size 25 cm as per direction of the PMC / Employer.

660

-

-

... More
Planting of Jetropha Plant (Jatropha multifida) foliage shrub variety of height 30-45 cm in polythene bag of size 6x7 inch including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the PMC / Employer.

622

-

-

... More
Providing, stacking and planting of Malpighia coccigera of height 30-45 cm., multibranched in earthen pots of size 20 cm as per direction of the PMC / Employer.

2749

-

-

... More
"Supplying and Planting of Nerium oleander foliage shrub variety of height 30-45 cm in polythene bag of size 6x7 inch including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the PMC / Employer."

185

-

-

... More
Providing, stacking and planting of Nerium oleander variegated of height 45-60 cm in earthen pots of size 20 cm as per direction of the PMC / Employer.

322

-

-

... More
Supplying and Planting of Plumbago (Plumnbego capensis) foliage shrub variety of height 30-45 cm in polythene bag of size 6x7 inch including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the PMC / Employer.

222

-

-

... More
"Supplying and Planting of Tabernum (Tabernaemontana coronaria) green foliage shrub variety of height 30-45 cm in polythene bag of size 6x7 inch including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the PMC / Employer."

265

-

-

... More
Supplying and Planting of Tecoma goudi choudi foliage shrub variety of height 30-45 cm in polythene bag of size 6x7 inch including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the PMC / Employer.

493

-

-

... More
Planting of Adenium (Adenium obessum) Specimen plant variety of height 105-120 cm in polythene bag of size 16x16 inch including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the PMC / Employer.

50

-

-

... More
Providing, stacking and planting of Raphis palm having ht. 75 cm to 90 cm with 12 to 15 equal suckers, well developed, full of fresh & healthy leaves from bottom to top in 25 cm size Earthen pot/Plastic pot & as per direction of the PMC / Employer.

496

-

-

... More
Supplying & planting of groundcovers

-

-

-

... More
Supplying and planting at site healthy,disease free and well developed groundcovers of the prescribed height as per detail below including cost of transportation, loading and unloading and providing the required intermittent care in the course of transportation and upto plantation. Plants to be supplied in polybag / HDPEbag / earthen pot of size as mentioned below.

-

-

-

... More
Providing, stacking and planting of Cuphea chinensis of ht. 20-30 cm full of branches and healthy foliage in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the PMC / Employer.

100

-

-

... More
Supplying and Planting of Duranta new gold Plant ornamental foliage shrub variety of height 30-45 cm in polythene bag of size 6x7 inch including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the PMC / Employer.

213

-

-

... More
Supplying and Planting of Wedelia trilobata foliage Ground cover variety in Polythene bag of size 6x7 inch the rate including loading and unloading charges, transportation, stacking of sapling at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by thePMC / Employer.

975

-

-

... More
Supplying and Planting of Chlorophytum ornamental foliage Ground cover variety in Polythene bag of size 6x7 inch the rate including loading and unloading charges, transportation, stacking of sapling at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the PMC / Employer.

2185

-

-

... More
Supplying & planting of lawn

-

-

-

... More
Turfing of Mexican grass including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the PMC / Employer.

1823

-

-

... More
MAINTENANCE

-

-

-

... More
Maintenance of shrubs, other ornamental foliage, foliage planting and Trees planting including watering, weeding, application of fertilizers and pesticides, trimming etc for One month

3957

-

-

... More
Maintenance of shades grass / carpet grass / G2 grass by regular watering, weeding, protection, mowing etc for a period of One month

1823

-

-

... More
ELECTRICAL WORKS

-

-

-

... More
HT PANELS

-

-

-

... More
33 KV Ring Main Gear (RMG) - OutdoorType Design, Manufacture, Assembly, Inspection and Testing before supply, Packing and delivery at Site, erection, Installation, Testing & commissioning of 33KV HT switchgear with all accessories and suitable for installation in three phase, three wire, 33kV,50Hz, A.C.distribution network, complete with all accessories erected in the provided foundation complete as per specfication and standards as directed by PMC/Employer in charge at Site. Outdoor Type Panel 33kV HT Ring Main Gear Comprising of Incomer : 2nos 800A ,26.3 KA, 3sec rating Horizontal Draw out type VCB including metering arrangements (AS PER TANGEDCO NORMS). Outgoings : 1no of 800A, 26.3 KA, 3sec rating Horizontal Draw out type VCB as outgoing including metering arrangements (AS PER TANGEDCO NORMS). Busbars: 33KV,800A,TP,50Hz,26.3 KA, Copper. Busbars The panel shall be provided with necessary protections, Measuring Instruments, Indicating Instruments, Protection Relays, CTs, PT with necessary control fuses/MCBs,Terminal Blocks,SPD, Earthing, Sign writing and Base channels etc., with complete all accessories as required for satisfactory operations and as per the detailed SIngle line Diagram and Technical specifications, Data sheets and as per TANGEDCO Requirements. The panel suitable for outdoor mounting & terminating of 400 sq.mm. 3 core HT XLPE 33KV as incoming and outgoing, Terminal Blocks, Earthing,Powder coated painting and Base channels etc., with complete all accessories as required for satisfactory operations as directed and approved by PMC/Employer in charge. Inbuilt battery backup needs to be considered. RMG yard Fencing and Foundation related items are covered under relveant items.HT panel yard Fencing and Foundation related items are covered under relveant items.

1

-

-

... More
Note: Vendor should procure the RMG as per latest amendement from TANGEDCO and Metering and Protection should be supplied as per TANGEDCO Requirements. No additional payment shall be provided from client.

-

-

-

... More
33 kV HT 4 VCB Panel - 1 (Outdoor Type ) Design, Manufacture, Assembly, Inspection and Testing before supply,Packing and delivery at Site, erection, Installation, Testing & commissioning of 33KV HT switchgear with all accessories and suitable for installation in three phase ,three wire,33kV,50Hz, A.C.distribution network, complete with all accessories erected in the provided foundation complete as per specfication and standards as directed by PMC/Employer in charge at Site. Outdoor Type Panel 33kV HT Panel-1 Comprising of Incomer : 1no 800A ,26.3 KA, 3sec rating Horizontal Draw out type VCB including metering arrangements Outgoings : 3nos of 800A, 26.3 KA, 3sec rating Horizontal Draw out type VCB as outgoing including metering arrangements Busbars: 33KV,800A,TP,50Hz,26.3 KA, Copper. Busbars The panel shall be provided with necessary protections, Measuring Instruments, Indicating Instruments, Protection Relays, Arc flashrelay,, CTs, PT with necessary control fuses/MCBs,Terminal Blocks,SPD, Earthing, Sign writing and Base channels etc., with complete all accessories as required for satisfactory operations and as per the detailed SIngle line Diagram and Technical specifications, Data sheets. The panel suitable for outdoor mounting & terminating of 400 sq.mm. 3 core HT XLPE 33KV as incoming and outgoing, Terminal Blocks, Earthing,Powder coated painting and Base channels etc., with complete all accessories as required for satisfactory operations as directed and approved by PMC/Employer in charge. Inbuilt battery backup needs to be considered. HT panel yard Fencing and Foundation related items are covered under relveant items.HT panel yard Fencing and Foundation related items are covered under relveant items.

1

-

-

... More
33 kV HT 4 VCB Panel - 2 (Indoor Type ) Design, Manufacture, Assembly, Inspection and Testing before supply, Packing and delivery at Site, erection, Installation, Testing & commissioning of 33KV HT switchgear with all accessories and suitable for installation in three phase, three wire, 33kV, 50Hz, A.C.distribution network, complete with all accessories erected in the provided foundation complete as per specfication and standards as directed by PMC/Employer in charge at Site. Indoor Type 33kV HT Panel-2 with Comprising of Incomer : 1no 800A ,26.3 KA, 3sec rating Horizontal Draw out type VCB including metering arrangements Outgoings : 3nos of 800A, 26.3 KA, 3sec rating Horizontal Draw out type VCB as outgoing including metering arrangements Busbars: 33KV,800A,TP,50Hz,26.3 KA, Copper. Busbars The panel shall be provided with necessary protections, Measuring Instruments, Indicating Instruments, Protection Relays, CTs, PT with necessary control fuses/MCBs,Terminal Blocks,SPD, Earthing, Sign writing and Base channels etc., with complete all accessories as required for satisfactory operations and as per the detailed SIngle line Diagram and Technical specifications, Data sheets.. The panel suitable for indoor mounting with Internal Arc & terminating of 400 sq.mm. 3 core HT XLPE 33KV as incoming and outgoing, Terminal Blocks, Earthing,Powder coated painting and Base channels etc., with complete all accessories as required for satisfactory operations as directed and approved by PMC/Employer in charge. Inbuilt battery backup needs to be considered.

1

-

-

... More
HT CABLE

-

-

-

... More
Supply, Laying, testing and commissioning of 3 core 400 sqmm 33KV, XLPE Aluminium conductor individual core screened, PVC sheathed, flat steel strip armoured earthed cable with specified IS 7098/11/85 with latest amendments. in hume pipe / cable trench (From 33KV RMG to HT 4 VCB panel-1, 4VCB panel-1 to HT indoor 4VCB panel-2 and HT indoor VCB 4 panel-2 to Transformers) If Cable shall be laid in ground , necessary excavation, sand brick protection and back filling of trench and made good as necessary for laying open with necessary cleats, clamps, pipe sleeves screws etc.

290

-

-

... More
Supply & Installation of indoor type heat shrinkable end termination kits and making End Terminations for XLPE insulated HT power cables 33kV (E) grade of 3Cx400sqmm size, including double Compression Gland of brass type, Aluminium lugs for Aluminium Cables and Bimetallic lugs at tranformer/panel end,including supply and fixing as per specification and direction of PMC / Employer.

8

-

-

... More
Supply & Installation of outdoor type heat shrinkable end termination kits and making End Terminations for XLPE insulated HT power cables 33kV (E) grade of 3Cx400sqmm size, including double Compression Gland of brass type, Aluminium lugs for Aluminium Cables and Bimetallic lugs at transformer/ panel end,including supply and fixing as per specification and direction of PMC / Employer.

4

-

-

... More
Substation Battery Charger: Design, supply, erection, testing and commissioning of Battery Charger 110V DC 200 AH Trip unit combined with trickle and Float & Boost charging facilities with battery banks (SMF) & Distribuition Board and complete with all accessories like insulators, clamps, bimetal connectors, M.S.support rack as required and as per technical specifications.

1

-

-

... More
TRANSFORMERS

-

-

-

... More
DRY TYPE DISTRIBUTION TRANSFORMER   Design, Engineering, Manufacturing, Supply and supervision , installation, testing and commissioning of 2500KVA , 33kV/433V, Cast Resin Dry Type Distribution Transformer, 3ph, 50Hz, with vacuum break On Load Tap changer on HT side & Insulation level Class F insulated, Vector Dyn11, Continuous duty, AN cooling, copper wound as per relevant standard with Resistive temperature detectors with enclosure should be embedded in winding, ventilation fans, RTCC panel, Marshalling box, Bidirectional rollers, HV Side Cable box & LV Side adapter box for connecting Bus duct, Painting to be RAL-7032. Transformer suitable indoor type distribution mounted inside enclouser with all standard accessories,Transformer shall be as per single line diagram and specifications / Technical Data Sheets. Enclosure for mounting Class PS Neutral CT for REF protection to be provided. The Transformer supplier shall co-ordinate with the panel vendor & install the Neutral CT . OLTC Tap settings: -10 % to +10%, 2.5% for each step. Primary Voltage: 33000V Secondary Voltage:433V. Losses- As per ECBC Building 2017. Lockable Emergency Push button should be provided . The civil works like construction of plinth, foundation etc shall be carried out by others. However, the correct sizes including type of construction shall be specified and a shop drawings shall be submitted by transformer supplier for approval before execution for review & approval by PMC / Employer. Note : Factory testing  shall be carried out as per the technical specifications on all the transformers. Testing shall include all routine tests as per latest IS / IEC standards and type test as mentioned in the specifications etc. All routine and type tests shall be carried out on all the transformers with out any extra cost as per PMC/ EMployer.

3

-

-

... More
LT PANELS

-

-

-

... More
Supply, erection, testing and commissioning of 415V, 3 phase 4 wire 50 Hz, fully compartmentalized cubical type, fabricated with CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having required capacity extensible type FP Copper alloy bus bars of high conductivity, DMC / SMC bus bars of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity as mentioned in the below & SLD, bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, Form of separation shall be form 4B with metallic separation only entire panel shall have a common copper earth bar size as per OEM requirements at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Cu. bus bars, interconnection, interlocking between feeders etc., Annuntiation window requirement shall be as per SLD. with indication lamps, push buttons necessary accessories, complete with following incoming and outgoing switchgears with protection and metering etc. as per specification and schematic diagram including provision to be made for interfacing with BMS etc. complete as required with incoming & outgoing cable entry from bottom/top and bus-duct entry from top, wiring with 2.5sq. mm. PVC insulated FRLS copper conductor , cable alleys, cable gland i/c providing following switch gears All ACBs should have Ics=Icu=Icw for 1 sec. All MCCBs shall be rating for Ics=Icu as per provided SLD. All MCCBs above 63A should be provided with Copper Spreader Terminals.Marshalling Bay To Be Provided for BMS Operation Please consider IP42 for Indoor panel & IP 55 for out door panels if it is not specified . Approval shall be taken for each panel before fabrication. contractor to consider the termination requirement as per the cable sizes sheet provided.

-

-

-

... More
If any additional termination box is required the same shall be considered by contractor in the panel cost itself. The fault level of the component shall be same as the bus bar fault level indicated. The panel shall be designed to suit to the site condition. If any U shape/L shape panels required as per site requirement, contractor to consider all required dummy panel, adaptor boxes, bus bar extension, other accessories, etc. in the panel cost itself. All the cost required for BMS integration like cable,control modules,converters, connectors etc as per the attached scheme shall be included in panel cost itself. The scope shall include relay coordination study. ON / OFF / TRIP status for all the incomming breakers (ACB, MCCB, MCB, MPCB, RCBO) & meter parameter from all main LT panel (Listed Below) to be provided through modbus IP output (PLC) to connect to BMS through ethernet switch located within one of the panels in each electrical room. All cost towards cable, ethernet switch, BMS interface module, etc shall be covered in the panel cost itself. LT panel with 400A & above shall be OEM Certified ( IEC 61439) type tested approved design. Below 400A shall be as per IEC 60439 design. Surge Protection device of sutibale type and range to be considered as per the SLD. Any details indicated in SLD and specification is also need to be consiedered for panel cost. Any details indicated in SLD and specification is also needs to be consiedered for panel cost. Internal ARC Flash test shall be provided for Mian LT Panels. Type Test certificates shall be submitted for all panel and its componenents. Note : Refer the SLD - TCE.13417A-EL-4002-AU-40011 to TCE.13417A-EL-4002-AU-40013 .

-

-

-

... More
MAIN LT PANEL - 1

1

-

-

... More
Incomer 4000A 4P EDO ACB 55 KA with microprocessor based O/L, S/C and E/F -3 Nos. Suitable for Bus Duct termination SPD type II, 55KA, FP - 3 nos Multi Function Meter with RS 485 port.-3 nos. C.T. 4000/1A, CLASS 0.5 10VA- 5sets. C.T. 4000/1A, CLASS PS - 2 sets. Line PT : 415V/v3/110V/v3, Cl.1, 10VA -3 nos For indication lamps please refer to SLD Bus Coupler 4000A FP EDO ACB (55kA),microprocessor based with O/L, S/C & E/F Protection as a buscoupler - 1 no For indication lamps please refer to SLD Mechanical & Electrical interlock between 3 Nos incomers and 1 No. Buscoupler Busbars: 4000A 4P Cu busbar 1sec (55kA)

-

-

-

... More
Outgoings : 55kA ALL ACB / MCCB 2500A 4P EDO ACB microprocessor based with O/L, S/C & E/F Protection - 3 nos. C.T. 2500/1A, CLASS 0.5 10VA- 3 sets 1600A 4P EDO ACB (55kA) microprocessor based with O/L, S/C & E/F Protection - 2 nos. C.T. 1600/1A, CLASS 0.5 10VA- 2 sets 1250A 4P EDO ACB (55kA) microprocessor based with O/L, S/C & E/F Protection - 3 nos. C.T. 1250/1A, CLASS 0.5 10VA- 3 sets 1000A 4P EDO ACB (55kA) microprocessor based with O/L, S/C & E/F Protection-1Nos C.T. 1000/1A, CLASS 0.5 10VA- 1 sets 800A 4P EDO ACB (55kA) microprocessor based with O/L, S/C & E/F Protection-1Nos C.T. 800/1A, CLASS 0.5 10VA- 1 sets 630A 4P MCCB (55kA) MP Based O/C, S/C & E/F Release- 3Nos C.T. 630/1A, CLASS 0.5 10VA- 3 sets 400A 4P MCCB (55kA) MP Based O/C, S/C & E/F Release- 1Nos C.T. 400/1A, CLASS 0.5 10VA- 1 sets Multi Function Meter with RS 485 port.- 14 nos. For indication lamps please refer to SLD for each Outgoings.

-

-

-

... More
The transformer incomer, DG incomer shall be provided with protection relays such as IDMT (3O/C + E/F), REFR (Restricted Earth fault Relay) etc., both the incomers, buscoupler shall be interlocked with mechanical and electrical arrangements by hardware control wiring along with PLC (Programmable Logic Controls). The PLC should have suitable communication port for BMS integration. All incoming and Outgoing breaker should be communicable for status monitoring. Please refer to single line diagram and technical specification for more details Supply, Installation, testing & commissioning of Inert type Novec-1230/FM200 Fire Detection Tube based Gas suppression system for electrical panel. It includes all the require accessories/equipments to complete the panel protection, as per detail specification.

-

-

-

... More
MAIN LT PANEL - 2

1

-

-

... More
Incomer 4000A 4P EDO ACB (55kA) with microprocessor based O/L, S/C and E/F - 3 No. Suitable for Bus Duct termination SPD type II, 55KA, FP -3 nos. Multi Function Meter with RS 485 port.- 3 nos. C.T. 4000/1A, CLASS 0.5 10VA- 5 set. C.T. 4000/1A, CLASS PS - 2 sets. Line PT : 415V/v3/110V/v3, Cl.1, 50VA - 3nos For indication lamps please refer to SLD Bus Coupler 4000A FP EDO ACB (55kA),microprocessor based with O/L, S/C & E/F Protection as a buscoupler - 1 no For indication lamps please refer to SLD Mechanical & Electrical interlock between 3 Nos incomers and 1 No. Buscoupler Busbars: 4000A 4P Cu busbar 1sec (55kA)

-

-

-

... More
Outgoing : 55kA ALL ACB / MCCB 2500A 4P EDO ACB (55kA) microprocessor based with O/L, S/C & inbuilt E/F Protection - 3nos. C.T. 2500/1A, CLASS 0.5 10VA- 3 sets 1600A 4P EDO ACB (55kA) microprocessor based with O/L, S/C & inbuilt E/F Protection - 2 nos. C.T. 1600/1A, CLASS 0.5 10VA- 2 sets 1250A 4P EDO ACB (55kA) microprocessor based with O/L, S/C & inbuilt E/F Protection - 3 nos. C.T. 1250/1A, CLASS 0.5 10VA- 3sets 800A 4P EDO ACB (55kA) microprocessor based with O/L, S/C & inbuilt E/F Protection- 2Nos C.T. 800/1A, CLASS 0.5 10VA- 2 sets 400A 4P MCCB (55kA) MP Based O/C, S/C & E/F Release- 5 Nos C.T. 400/1A, CLASS 0.5 10VA- 5 sets Multi Function Meter with RS 485 port.- 15nos. For indication lamps please refer to SLD for each Outgoings.

-

-

-

... More
The transformer incomer, DG incomer shall be provided with protection relays such as IDMT (3O/C + E/F), REFR (Restricted Earth fault Relay) etc., both the incomers, buscoupler shall be interlocked with mechanical and electrical arrangements by hardware control wiring along with PLC (Programmable Logic Controls). The PLC should have suitable communication port for BMS integration. All incoming and Outgoing breaker should be communicable for status monitoring. Please refer to single line diagram and technical specification for more details Supply, Installation, testing & commissioning of Inert type Novec-1230/FM200 Fire Detection Tube based Gas suppression system for electrical panel. It includes all the require accessories/equipments to complete the panel protection, as per detail specification.

-

-

-

... More
TIE BREAKER LT PANEL

1

-

-

... More
Incomer 4000A 4P EDO ACB (55kA) with microprocessor based O/L, S/C and E/F - 2 No. Suitable for Bus Duct termination SPD type II, 55KA, FP - 2 nos. C.T. 4000/1A, CLASS 0.5 10VA- 2 set. Multi Function Meter with RS 485 port.- 2 no. Line PT : 415V/v3/110V/v3, Cl.1, 50VA - 2 no For indication lamps please refer to SLD Busbars: 4000A 4P Cu busbar 1sec (55kA) For indication lamps please refer to SLD Mechanical & Electrical interlock between 2 Nos incomers Outgoing : 55kA ALL ACB / MCCB 4000A 4P EDO ACB (55kA) microprocessor based with O/L, S/C & inbuilt E/F Protection - 2 Nos. For indication lamps please refer to SLD. Suitable for Bus Duct termination

-

-

-

... More
The transformer incomer, DG incomer shall be provided with protection relays such as IDMT (3O/C + E/F), REFR (Restricted Earth fault Relay) etc., both the incomers, buscoupler shall be interlocked with mechanical and electrical arrangements by hardware control wiring along with PLC (Programmable Logic Controls). The PLC should have suitable communication port for BMS integration. All incoming and Outgoing breaker should be communicable for status monitoring. Please refer to single line diagram and technical specification for more details Supply, Installation, testing & commissioning of Inert type Novec-1230/FM200 Fire Detection Tube based Gas suppression system for electrical panel. It includes all the require accessories/equipments to complete the panel protection, as per detail specification.

-

-

-

... More
HVAC PANEL 1

1

-

-

... More
Incomer 2500A 4P EDO ACB (50kA) with microprocessor based O/L, S/C and E/F - 1 No. SPD type II, 50KA, FP - 1 no. C.T.2500/1A, CLASS 0.5 10VA- 1set. Multi Function Meter with RS 485 port.- 1no. For indication lamps please refer to SLD Busbars: 2500A TPN Cu Busbars (50kA) 1Sec Outgoing : 50kA ALL MCCB 630A TPN MCCB MP Based O/C & S/C Release (50kA) - 4 Nos C.T. 630/1A, CLASS -1.0 10VA- 4 sets 315A TPN MCCB MP Based O/C & S/C Release (50kA) - 1 No C.T. 315/1A, CLASS -1.0 10VA- 1sets 250A TPN MCCB MP Based O/C & S/C Release (50kA) with Star-Delta starter suitable for 45 KW motor - 3 Nos (Breaker is Suitable for Motor Appication) 250A TPN MCCB MP Based O/C & S/C Release (50kA) - 2 Nos C.T. 250/1A, CLASS 1.0 10VA- 2 sets 160A TPN MCCB TM Based O/C & S/C Release (50kA)with Star-Delta starter suitable for 30 KW motor - 3 Nos (Breaker is Suitable for Motor Appication) C.T. 160/1A, CLASS 1.0 10VA- 3 sets Multi Function Meter with RS 485 port.- 13nos. For indication lamps please refer to SLD Please refer to single line diagram and technical specification for more details

-

-

-

... More
HVAC PANEL 2

1

-

-

... More
Incomer 2500A 4P EDO ACB (50kA) with microprocessor based O/L, S/C and E/F - 1 Nos. SPD type II, 50KA, FP - 1 no. C.T.2500/1A, CLASS 0.5 10VA- 1set. For indication lamps please refer to SLD Multi Function Meter with RS 485 port.- 1no. Busbars: 2500A TPN Cu Busbars: (50kA) Outgoing : 50kA ALL MCCB 630A TPN MCCB MP Based O/C & S/C Release (50kA) - 3 Nos C.T. 630/1A, CLASS 1.0 10VA- 3 sets 400A TPN MCCB MP Based O/C & S/C Release (50kA) - 2 Nos C.T. 400/1A, CLASS 1.0 10VA-2 sets 250A TPN MCCB TM Based O/C & S/C Release (50kA) - 4 Nos C.T. 250/1A, CLASS 1.0 10VA-4 sets 250A TPN MCCB TM Based O/C & S/C Release (50kA) with Star-Delta starter suitable for 45 KW motor - 2 Nos (Breaker is Suitable for Motor Appication) C.T. 250/1A, CLASS 1.0 10VA-2 sets 160A TPN MCCB TM Based O/C & S/C Release (50kA) with Star-Delta starter suitable for 30 KW motor -2 Nos (Breaker is Suitable for Motor Appication) C.T. 160/1A, CLASS 1.0 10VA-2 sets Multi Function Meter with RS 485 port.- 13 nos. For indication lamps please refer to SLD Please refer to single line diagram and technical specification for more details

-

-

-

... More
EV CHARGING PANEL -1 (OUTDOOR TYPE)

1

-

-

... More
Incomer 400A 4P MCCB (36kA) with MP based O/L, S/C and E/F - 1 No. SPD type II, 36KA, FP - 1 no. C.T.400/1A, CLASS 0.5 10VA- 1set. For indication lamps please refer to SLD Multi Function Meter with RS 485 port.- 1no. Busbars: 400A TPN Cu Busbars (36kA) 1Sec Outgoing : 250A TPN MCCB MP Based O/C & S/C Release (36kA) - 2 Nos 40A DP MCB - 11 Nos KWh Energy meter with RS 485 port.- 8nos. For indication lamps please refer to SLD Please refer to single line diagram and technical specification for more details

-

-

-

... More
EV CHARGING PANEL -2 (OUTDOOR TYPE)

1

-

-

... More
Incomer 250A 4P MCCB (36kA) MP BASED with microprocessor based O/L, S/C and E/F - 1 No. SPD type II, 36KA, FP - 1 no. C.T.250/1A, CLASS 0.5 10VA- 1set. For indication lamps please refer to SLD Multi Function Meter with RS 485 port.- 1no. Busbars: 250A TPN Cu Busbars (36kA) 1sec Outgoing : 40A 4P MCB - 20 Nos KWh Energy meter with RS 485 port.- 20nos. For indication lamps please refer to SLD Please refer to single line diagram and technical specification for more details

-

-

-

... More
APFC PANEL - 1 ,2,3,4 (HYBRID PANEL)

4

-

-

... More
Incomer 1250A 4P EDO ACB (50kA) with MP Based O/C, S/C & E/F Release- 1No Busbar: 1250A TP Cu Busbars (50kA) 1sec Outgoing : 400 Amp MP Based O/C & S/C Release MCCB (50kA). - 2 Nos with 200A active Harmonic Filters Active Filters consists of IGBT based Active technology with complete forced cooling arrangement Interfacing and other control cards, Sensor control card, SMPS, Precharge circuit , Interconnection with UNIVYNIN copper stranded wires, busbars, earth busbar, danger notice boards, inscription plates, terminals for incoming & outgoing cable connections.MCCB, contactor and fuses of applicable rating and protections shall be provided for the active filter. 250 Amp MP Based O/C & S/C Release MCCB (50kA) with suitable rating TP capacitor duty contactor (Suitable for 100 KVAR capacitor bank). - 4Sets 125Amp TM Based O/C & S/C Release MCCB (50kA) with suitable rating TP capacitor duty contactor (Suitable for 50 KVAR capacitor bank). - 1Sets 125Amp TM Based O/C & S/C Release MCCB (50kA) with suitable rating TP capacitor duty contactor (Suitable for 2x25 KVAR capacitor bank). - 2Sets CT with Analog Ammeter with selctor switch -1set for each outgoings Indication lamp please refer to SLD Instruments Panel - 7 inch LCD touchscreen for all parameters related to IGBT based system - 01No Please refer to single line diagram and technical specification for more details. Hybrid APFC Panel shall comprise IGBT based active technology (for reactive and harmonics compensation) and detuned capacitor banks(for reactive compensation). The entire system shall be controlled through a single integrated controller for Active and Detuned capacitors.

-

-

-

... More
UPS OUTPUT PANEL 1

1

-

-

... More
Incomer 100A 4P TM MCCB (25kA) O/C, S/C & E/F Release- 1No RYB on, off trip indication lamp - 1 set. C.T. 100/1A, CLASS 0.5 10VA- 1 nos. SPD type II, 25KA, FP - 1 nos. Multi Function Meter with RS 485 port.- 1no. Busbars: 100A TP+2N Cu Busbars (25kA) 1Sec Outgoing : 40A 4P MCB - 19 Nos For indication lamp refer SLD. Please refer to single line diagram and technical specification for more details

-

-

-

... More
UPS OUTPUT PANEL 2

1

-

-

... More
Incomer 160A 4P TM MCCB (25kA) O/C, S/C & E/F Release- 1No RYB on, off trip indication lamp - 1 set. C.T. 160/1A, CLASS 0.5 10VA- 1 nos. SPD type II, 25KA, FP - 1 no. Multi Function Meter with RS 485 port.- 1no. Busbars: 160A TP+2N Cu. Busbars (25kA) 1Sec Outgoing : 40A 4P MCB - 20Nos 63A 4P MCCB TM based (25kA)O/C & S/C Release -2 nos. 40A 4P MCCB TM based (25kA)O/C & S/C Release -2 nos. For indication lamp refer SLD. Please refer to single line diagram and technical specification for more details

-

-

-

... More
UTILITY PANEL

1

-

-

... More
Incomer 800A 4P EDO ACB (50kA) with microprocessor based O/L, S/C and E/F - 2 Nos. 250A 4P MCCB (50kA) MP Based O/C, S/C & E/F Release- 1No RYB on, off trip indication lamp -3 set. C.T.800/1A, CLASS 0.5 10VA- 2 set. C.T.250/1A, CLASS 0.5 10VA- 1 set. Multi Function Meter with RS 485 port.-3nos. Electrical interlock between 3 incomers SPD type II, 50KA, FP - 3 nos. Busbars: 800A TPN Cu. Busbars: (50kA) ,1sec Outgoing : 400A TPN MCCB MP based O/C & S/C Release (50kA) - 1 no. C.T.400/1A, CLASS 1.0 10VA- 1set. 315A TPN MCCB MP based O/C & S/C Release (50kA) - 1 no. C.T.315/1A, CLASS 1.0 10VA- 1 set 250A TPN MCCB MP based O/C & S/C Release (50kA) - 1 no. C.T.250/1A, CLASS 1.0 10VA- 1 set 200A TPN MCCB TM based O/C & S/C Release (50kA) - 2 nos. C.T.200/1A, CLASS 1.0 10VA- 2 set 100A TPN MCCB TM based O/C & S/C Release (50kA) - 2 nos. C.T.100/1A, CLASS 1.0 10VA- 2set 63A TPN MCCB TM based O/C & S/C Release (50kA) - 4 nos. C.T.63/1A, CLASS 1.0 10VA- 4set On, off trip indication lamp - 11 sets. Multi Function Meter-11 nos Please refer to single line diagram and technical specification for more details

-

-

-

... More
COMMON AREA LIGHTING PANEL

1

-

-

... More
Incomer 100A 4P MCCB (25kA) TM Based O/C, S/C & E/F Release-1Nos RYB on, off trip indication lamp -1 set. C.T. 100/1A, CLASS 0.5 10VA- 1 set. Multi Function Meter with RS 485.- 1 nos SPD type II, 25KA, FP - 1 no. Busbars: 100A TPN Cu. Busbars: (25kA) 1Sec Outgoing : 40A 4P MCB - 18 Nos Please refer to single line diagram and technical specification for more details

-

-

-

... More
COMMON AREA POWER PANEL

1

-

-

... More
Incomer 200A 4P MCCB (25kA) TM Based O/C, S/C & E/F Release-1No RYB on, off trip indication lamp -1 set. C.T. 200/1A, CLASS 0.5 10VA- 1 set. Multi Function Meter with RS 485.- 1 no SPD type II, 25KA, FP - 1 no. Busbars: 200A TPN Cu. Busbars: (25kA),1Sec Outgoing : 63A 4P MCB - 20 Nos Please refer to single line diagram and technical specification for more details

-

-

-

... More
PHE PANEL

1

-

-

... More
Incomer 400A 4P MCCB (36kA) MP Based O/C, S/C & E/F Release- 1No RYB on, off trip indication lamp -1 set. C.T.400/1A, CLASS 0.5 10VA- 1 set. Multi Function Meter with RS 485 port.- 1 no. SPD type II, 36KA, FP - 1 nos. Busbars: 400A TPN Cu Busbars: (36kA),1 Sec Outgoing : 63A TPN MCCB TM based O/C & S/C Release (36kA) - 6 nos. 40A TPN MCCB TM based O/C & S/C Release (36kA) - 13nos. Please refer to single line diagram and technical specification for more details

-

-

-

... More
UPS INPUT PANEL

1

-

-

... More
Incomer 400A 4P MCCB (36kA) with MP based O/L, S/C and E/F - 2 Nos. RYB on, off trip indication lamp -2 set. SPD type II, 36KA, FP - 2 nos. C.T.400/1A, CLASS 0.5 10VA-- 2 sets. Multi Function Meter with RS 485 port.- 2 nos. Electrical interlock between 2 incomers Busbars: 400A 4P CU Busbars: (36kA),1Sec Outgoing : 36kA ALL MCCB 250A TPN MCCB MP Based O/C & S/C Release (36kA) - 2 Nos 100A TPN MCCB TM Based O/C & S/C Release (36kA) - 2 Nos For indication lamps please refer to SLD Please refer to single line diagram and technical specification for more details

-

-

-

... More
EXTERNAL VENTILATION PANEL(FOR STP & SWM)

1

-

-

... More
Incomer 100A 4P MCCB (25kA) with TM based O/L, S/C and E/F - 1 No. RYB on, off trip indication lamp -1 set. SPD type II, 25KA, FP - 1 no. C.T.100/1A, CLASS 0.5 10VA-- 1 set. Multi Function Meter with RS 485 port.- 1 no. Busbars: 100A TPN CU Busbars: (25kA),1Sec Outgoing : 25kA ALL MCCB 40A TPN MCCB TM Based O/C & S/C Release (25kA) - 7 Nos C.T.40/1A, CLASS 1.0 10VA- 6 sets. For indication lamps please refer to SLD Please refer to single line diagram and technical specification for more details

-

-

-

... More
FIRE EMERGENCY PANEL

1

-

-

... More
Incomer 1600A 4P EDO ACB 50 KA with microprocessor based O/L, S/C and E/F - 2Nos For indication lamps please refer to SLD SPD type II, 50KA, FP - 2 nos. C.T. 1600/1A, CLASS 0.5 10VA-- 2 set. Multifunction meter with RS485- 2nos Mech & Electrical interlock between 2 incomers Busbars: 1600A FP Cu. Busbars: (50kA),1Sec Outgoing : 630A 4P MCCB MP based O/C & S/C Release (50kA) - 3 nos. C.T.630/1A, CLASS 1.0 10VA- 3 set. 400A 4P MCCB MP based O/C & S/C Release (50kA) - 2 nos. C.T.400/1A, CLASS 1.0 10VA- 2 set. 160A 4P MCCB TM based O/C & S/C Release (50kA) -2 nos. C.T.160/1A, CLASS 1.0 10VA- 3set. Multifunction meter with RS485- 7nos For indication lamps,Pushbutton,Selctor switch, please refer to SLD Please refer to single line diagram and technical specification for more details Supply, Installation, testing & commissioning of Inert type Novec-1230/FM200 Fire Detection Tube based Gas suppression system for electrical panel. It includes all the require accessories/equipments to complete the panel protection, as per detail specification.

-

-

-

... More
ELEVATOR PANEL

1

-

-

... More
Incomer 630A 4P MCCB (36kA) MP Based O/C, S/C & E/F Release- 1No RYB on, off trip indication lamp -1set. SPD type II, 36KA, FP - 1 nos. C.T. 630/1A, CLASS 0.5 10VA-- 1 set. Multifunction meter with RS485- 1no Busbars: 630A TPN CU Busbars: (36kA),1Sec Outgoing : 63A TPN MCCB TM based O/C & S/C Release (36kA) - 14 nos. C.T.63/1A, CLASS 1.0 10VA- 14 set. Multi Function Meter with RS 485 - 14nos For indication lamps,Pushbutton,Seelctor switch, please refer to SLD Please refer to single line diagram and technical specification for more details Supply, Installation, testing & commissioning of Inert type Novec-1230/FM200 Fire Detection Tube based Gas suppression system for electrical panel. It includes all the require accessories/equipments to complete the panel protection, as per detail specification.

-

-

-

... More
PRESSURIZATION PANEL

1

-

-

... More
Incomer 400A 4P MCCB (25kA) MP Based O/C, S/C & E/F Release- 1No RYB on, off trip indication lamp -1set. C.T. 400/1A, CLASS 0.5 10VA- 1 set. Multifunction meter with RS 485 port.- 1 no SPD type II, 25KA, FP - 1 no. Busbars: 400A TPN Cu Busbars: (25kA),1Sec Outgoing : 5.5kW DOL Starter SPPR, MPCB with inbuilt thermal overload relay, Auxiliary relays, Contactors – 4 set. 7.5kW DOL Starter SPPR, MPCB with inbuilt thermal overload relay, Auxiliary relays, Contactors –17set. 11kW Star Delta Starter SPPR, MPCB with inbuilt thermal overload relay, Auxiliary relays, Contactors –3set. 18.5kW Star Delta Starter SPPR, MPCB with inbuilt thermal overload relay, Auxiliary relays, Contactors –1set. For indication lamps,Pushbutton,Seelctor switch, please refer to SLD Please refer to single line diagram and technical specification for more details

-

-

-

... More
GROUND FLOOR HVAC PANEL

1

-

-

... More
Incomer 250A 4P MCCB (25kA) MP Based O/C, S/C & E/F Release- 1Nos RYB on, off trip indication lamp -1set. C.T. 250/1A, CLASS 0.5 10VA- 1 set. Multifunction meter with RS 485 port.- 1 nos SPD type II, 25KA, FP - 1 nos. Busbars: 250A TPN Cu Busbars: (25kA),1Sec Outgoing : 32A TPN MCCB TM based O/C & S/C Release (25kA) - 6nos. C.T. 32/1A, CLASS 1.0 10VA- 6 set. 40A TPN MCCB TM based O/C & S/C Release (25kA) - 2nos. C.T. 40/1A, CLASS 1.0 10VA-2 set. 63A TPN MCCB TM based O/C & S/C Release (25kA) - 2nos. C.T. 63/1A, CLASS 1.0 10VA-2 set. 3.7kW DOL Starter SPPR, MPCB with inbuilt thermal overload relay, Auxiliary relays, Contactors – 4 set. 5.5kW DOL Starter SPPR, MPCB with inbuilt thermal overload relay, Auxiliary relays, Contactors – 3 set. 3.2kW DOL Starter SPPR, MPCB with inbuilt thermal overload relay, Auxiliary relays, Contactors –1 set. 15kW Star Delta Starter SPPR, MPCB with inbuilt thermal overload relay, Auxiliary relays, Contactors –6set. Multifunction meter with RS 485 port.- 10 nos For indication lamps,Pushbutton,Seelctor switch, please refer to SLD Please refer to single line diagram and technical specification for more details

-

-

-

... More
TERRACE VENTILATION PANEL (OUTDOOR TYPE)

1

-

-

... More
Incomer 400A 4P MCCB (25kA) MP Based O/C, S/C & E/F Release- 1Nos RYB on, off trip indication lamp -1set. C.T. 400/1A, CLASS 0.5 10VA- 1 set. Multifunction meter with RS 485 port.- 1 nos SPD type II, 25KA, FP - 1 no. Busbars: 400A TPN Cu Busbars: (25kA),1Sec Outgoing : 100A TPN MCCB TM based O/C & S/C Release (25kA) - 2nos. 63A TPN MCCB TM based O/C & S/C Release (25kA) - 6nos. 40A TPN MCCB TM based O/C & S/C Release (25kA) - 11nos. 1.5kW DOL Starter SPPR, MPCB with inbuilt thermal overload relay, Auxiliary relays, Contactors –6set. 100A TPN MCCB TM based O/C & S/C Release (25kA) with VFD starter suitable for 37KW motor - 1 nos. 7.5 kW Star delta Starter SPPR, MPCB with inbuilt thermal overload relay, Auxiliary relays, Contactors – 1 set. All VFDs shall comply with IEC 61800-3 & have THD less than 5% which will be in scope of Drive authorized supplier of OEM as per list of approved make. For indication lamps,Pushbutton,Seelctor switch, please refer to SLD Please refer to single line diagram and technical specification for more details

-

-

-

... More
AIR COOLED CHILLER PANEL (OUTDOOR TYPE)

1

-

-

... More
Incomer 630A FP MCCB (36kA) MP Based O/C, S/C & E/F Release-2Nos RYB on, off trip indication lamp -2 sets. C.T.630/1A, CLASS 0.5 10VA- 2set. Multi Function Meter with RS 485 port.- 2 nos. SPD type II, 36KA, FP - 2 no. Busbars: 630A 4P Cu Busbars: (36kA),1Sec Outgoing : 400A TPN MCCB MP  based O/C & S/C Release (36kA) - 3 nos. C.T.400/1A, CLASS 1.0 10VA- 3 set. 63A TPN MCCB TM  based O/C & S/C Release (36kA) -3nos. C.T.63/1A, CLASS 1.0 10VA- 3set 5.5kW DOL Starter SPPR, MPCB with inbuilt thermal overload relay, Auxiliary relays, Contactors – 3 set. Multi Function Meter with RS 485-8 nos Please refer to single line diagram and technical specification for more detail

-

-

-

... More
COOLING TOWER FAN PANEL (OUTDOOR TYPE)

1

-

-

... More
Incomer 250A 4P MCCB (36kA) MP Based O/C, S/C & E/F Release-2Nos RYB on, off trip indication lamp -2 set. C.T.250/1A, CLASS 0.5 10VA- 2set. Multi Function Meter with RS 485 port.- 2 nos. SPD type II, 36KA, FP - 1 no. Busbars: 250A 4P Cu Busbars: (25kA),1Sec Outgoing : 63A TPN MCCB TM  based O/C & S/C Release (36kA) with VFD  starter suitable for 18.5KW motor -9 nos. C.T.63/1A, CLASS 1.0 10VA- 9 set Multi Function Meter with RS 485-9 nos All VFDs shall comply with IEC 61800-3 & have THD less than 5% which will be in scope of Drive authorized supplier of OEM as per list of approved make. Please refer to single line diagram and technical specification for more details

-

-

-

... More
LIFT CONTROL PANEL (WALL MOUNTING TYPE TYPICAL)

12

-

-

... More
Incomer 63A 4P MCCB (16kA) TM Based O/C, S/C & E/F Release-1No RYB on, off trip indication lamp -1 set. Busbars: 63A FP Cu Busbars: (16kA),1sec Outgoing : 40A 4P RCBO 300mA -2 nos. 32A DP RCBO 100mA -2 nos. 32A DP MCB -2 nos. Please refer to single line diagram and technical specification for more details

-

-

-

... More
GF MAIN POWER PANEL

1

-

-

... More
Incomer 125 4P On Load Manual change over switch-1no. 125A 4P MCCB (25kA) TM Based O/C, S/C & E/F Release-1No RYB on, off trip indication lamp -1 set. C.T.125/1A, CLASS 0.5 10VA- 1set. Type-2 SPD 25KA-1 no Multi Function Meter with RS 485 -1 no. On, off indication lamp - 2 sets. Busbars: 125A 4P Cu Busbars: (25kA),1Sec Outgoing : 40A 4P MCCB TM based O/C & S/C Release (25kA) -5 nos. C.T.40/1A, CLASS 1.0 10VA- 5 set 63A 4P MCCB TM based O/C & S/C Release (25kA) -3 nos. C.T.40/1A, CLASS 1.0 10VA- 3 sets Multi Function Meter with RS 485-8 nos Please refer to single line diagram and technical specification for more details

-

-

-

... More
1F MAIN POWER PANEL

1

-

-

... More
Incomer 630A 4P On Load Manual change over switch-1no. 630A 4P MCCB (36kA) MP Based O/C, S/C & E/F Release-1No RYB on, off trip indication lamp -1 set. C.T.630/1A, CLASS 0.5 10VA- 1set. Type-2 SPD 36KA-1 no Multi Function Meter with RS 485 -1 no. On, off indication lamp -2 sets. Busbars: 630A 4P Cu Busbars: (36kA),1Sec Outgoing : 400A 4P MCCB MP based O/C & S/C Release (36kA) -2 nos. C.T.400/1A, CLASS 1.0 10VA- 2 set 100A 4P MCCB TM based O/C & S/C Release (36kA) -1 nos. C.T.100/1A, CLASS 1.0 10VA- 1 set 63A 4P MCCB TM based O/C & S/C Release (36kA) -2nos. C.T.63/1A, CLASS 1.0 10VA- 2 set 40A 4P MCCB TM based O/C & S/C Release (36kA) -10 nos. C.T.40/1A, CLASS 1.0 10VA- 10set 3.7kW DOL Starter SPPR, MPCB with inbuilt thermal overload relay, Auxiliary relays, Contactors –3set. Multi Function Meter with RS 485-18nos Please refer to single line diagram and technical specification for more details

-

-

-

... More
1F CAFE PANEL

1

-

-

... More
Incomer 400A 4P MCCB (25kA) MP Based O/C, S/C & E/F Release-1No. RYB on, off trip indication lamp -1 set. C.T.400/1A, CLASS 0.5 10VA- 1set. Type-2 SPD 25KA-1 nos Multi Function Meter with RS 485 -1 no. Commercial meter provision -1no. Busbars: 400A 4P Cu Busbars: (25kA),1Sec Outgoing : 100A 4P MCCB TM based O/C & S/C Release (25kA) -4 nos. C.T.100/1A, CLASS 1.0 10VA- 4 set 63A 4P MCCB TM based O/C & S/C Release (25kA) -5 nos. C.T.63/1A, CLASS 1.0 10VA- 5 set 40A 4P MCCB TM based O/C & S/C Release (25kA) -16 nos. C.T.40/1A, CLASS 1.0 10VA- 16 set Multi Function Meter with RS 485-25 nos Please refer to single line diagram and technical specification for more details

-

-

-

... More
2F MAIN POWER PANEL

1

-

-

... More
Incomer 250A 4P Onload Manual Changeover switch-1no. 250A 4P MCCB (25kA) MP Based O/C, S/C & E/F Release-1No RYB on, off trip indication lamp -1 set. C.T.250/1A, CLASS 0.5 10VA- 1set. Type-2 SPD 25KA-1 nos Multi Function Meter with RS 485 -1 no. On, off indication lamp - 2 sets. Busbars: 250A 4P Cu Busbars: (25kA),1Sec Outgoing : 125A 4P MCCB TM based O/C & S/C Release (25kA) -3nos. C.T.125/1A, CLASS 1.0 10VA- 3 set 63A 4P MCCB TM based O/C & S/C Release (25kA) -4 nos. C.T.63/1A, CLASS 1.0 10VA- 4 set 40A 4P MCCB TM based O/C & S/C Release (25kA) -5 nos. C.T.40/1A, CLASS 1.0 10VA- 5 set Multi Function Meter with RS 485-12 nos Please refer to single line diagram and technical specification for more details

-

-

-

... More
2F HVAC POWER PANEL

1

-

-

... More
125A 4P MCCB (25kA) TM Based O/C, S/C & E/F Release-1No RYB on, off trip indication lamp -1 set. C.T.125/1A, CLASS 0.5 10VA- 1set. Type-2 SPD 25KA-1 no Multi Function Meter with RS 485 -1 no. Busbars: 125A 4P Cu Busbars: (25kA),1Sec Outgoing : 32A 4P MCCB TM based O/C & S/C Release (25kA) -12 nos. C.T.32/1A, CLASS 1.0 10VA-12 set 40A 4P MCCB TM based O/C & S/C Release (25kA) -3nos. C.T.40/1A, CLASS 1.0 10VA-3 set Multi Function Meter with RS 485-15nos Please refer to single line diagram and technical specification for more details

-

-

-

... More
3F MAIN POWER PANEL

1

-

-

... More
Incomer 400A 4P Onload Manual Changeover switch-1no 400A 4P MCCB (25kA) MP Based O/C, S/C & E/F Release-1No RYB on, off trip indication lamp -1 set. C.T.400/1A, CLASS 0.5 10VA- 1set. Type-2 SPD 25KA-1 nos Multi Function Meter with RS 485 -1 no. On, off indication lamp - 2sets. Busbars: 400A 4P Cu Busbars: (25kA),1Sec Outgoing : 125A 4P MCCB TM based O/C & S/C Release (25kA) -11nos. C.T.125/1A, CLASS 1.0 10VA- 11 set 200A 4P MCCB TM based O/C & S/C Release (25kA) -2 nos. C.T.200/1A, CLASS 1.0 10VA- 2 set Multi Function Meter with RS 485-13 nos Please refer to single line diagram and technical specification for more details

-

-

-

... More
3F HVAC POWER PANEL

1

-

-

... More
Incomer 200A 4P MCCB (25kA) TM Based O/C, S/C & E/F Release-1No RYB on, off trip indication lamp -1 set. C.T.200/1A, CLASS 0.5 10VA- 1set. Type-2 SPD 25KA-1 no Multi Function Meter with RS 485 -1 no. Busbars: 200A 4P Cu Busbars: (25kA),1Sec Outgoing : 63A 4P MCCB TM based O/C & S/C Release (25kA) -4 nos. C.T.63/1A, CLASS 1.0 10VA- 4 set 40A 4P MCCB TM based O/C & S/C Release (25kA) -12 nos. C.T.40/1A, CLASS 1.0 10VA- 12sets. Multi Function Meter with RS 485-16 nos Please refer to single line diagram and technical specification for more details.

-

-

-

... More
4F MAIN POWER PANEL

1

-

-

... More
Incomer 400A 4P Onload Manual Changeover switch-1no 400A 4P MCCB (25kA) MP Based O/C, S/C & E/F Release-1No RYB on, off trip indication lamp -1 set. C.T.400/1A, CLASS 0.5 10VA- 1set. Type-2 SPD 25KA-1 nos Multi Function Meter with RS 485 -1 no. On, off indication lamp - 2sets. Busbars: 400A 4P Cu Busbars: (25kA),1Sec Outgoing : 125A 4P MCCB TM based O/C & S/C Release (25kA) -11nos. C.T.125/1A, CLASS 1.0 10VA- 11 set 200A 4P MCCB TM based O/C & S/C Release (25kA) -2 nos. C.T.200/1A, CLASS 1.0 10VA- 2 set Multi Function Meter with RS 485-13 nos Please refer to single line diagram and technical specification for more details

-

-

-

... More
4F HVAC POWER PANEL

1

-

-

... More
Incomer 200A 4P MCCB (25kA) TM Based O/C, S/C & E/F Release-1No RYB on, off trip indication lamp -1 set. C.T.200/1A, CLASS 0.5 10VA- 1set. Type-2 SPD 25KA-1 no Multi Function Meter with RS 485 -1 no. Busbars: 200A 4P Cu Busbars: (25kA),1Sec Outgoing : 63A 4P MCCB TM based O/C & S/C Release (25kA) -4 nos. C.T.63/1A, CLASS 1.0 10VA- 4 set 40A 4P MCCB TM based O/C & S/C Release (25kA) -12 nos. C.T.40/1A, CLASS 1.0 10VA- 12sets. Multi Function Meter with RS 485-16 nos Please refer to single line diagram and technical specification for more details.

-

-

-

... More
5F MAIN POWER PANEL

1

-

-

... More
Incomer 400A 4P Onload Manual Changeover switch-1no 400A 4P MCCB (25kA) MP Based O/C, S/C & E/F Release-1No RYB on, off trip indication lamp -1 set. C.T.400/1A, CLASS 0.5 10VA- 1set. Type-2 SPD 25KA-1 nos Multi Function Meter with RS 485 -1 no. On, off indication lamp - 2sets. Busbars: 400A 4P Cu Busbars: (25kA),1Sec Outgoing : 125A 4P MCCB TM based O/C & S/C Release (25kA) -11nos. C.T.125/1A, CLASS 1.0 10VA- 11 set 200A 4P MCCB TM based O/C & S/C Release (25kA) -2 nos. C.T.200/1A, CLASS 1.0 10VA- 2 set Multi Function Meter with RS 485-13 nos Please refer to single line diagram and technical specification for more details

-

-

-

... More
5F HVAC POWER PANEL

1

-

-

... More
Incomer 200A 4P MCCB (25kA) TM Based O/C, S/C & E/F Release-1No RYB on, off trip indication lamp -1 set. C.T.200/1A, CLASS 0.5 10VA- 1set. Type-2 SPD 25KA-1 no Multi Function Meter with RS 485 -1 no. Busbars: 200A 4P Cu Busbars: (25kA),1Sec Outgoing : 63A 4P MCCB TM based O/C & S/C Release (25kA) -4 nos. C.T.63/1A, CLASS 1.0 10VA- 4 set 40A 4P MCCB TM based O/C & S/C Release (25kA) -12 nos. C.T.40/1A, CLASS 1.0 10VA- 12sets. Multi Function Meter with RS 485-16 nos Please refer to single line diagram and technical specification for more details.

-

-

-

... More
6F MAIN POWER PANEL

1

-

-

... More
Incomer 400A 4P Onload Manual Changeover switch-1no 400A 4P MCCB (25kA) MP Based O/C, S/C & E/F Release-1No RYB on, off trip indication lamp -1 set. C.T.400/1A, CLASS 0.5 10VA- 1set. Type-2 SPD 25KA-1 nos Multi Function Meter with RS 485 -1 no. On, off indication lamp - 2sets. Busbars: 400A 4P Cu Busbars: (25kA),1Sec Outgoing : 125A 4P MCCB TM based O/C & S/C Release (25kA) -11nos. C.T.125/1A, CLASS 1.0 10VA- 11 set 200A 4P MCCB TM based O/C & S/C Release (25kA) -2 nos. C.T.200/1A, CLASS 1.0 10VA- 2 set Multi Function Meter with RS 485-13 nos Please refer to single line diagram and technical specification for more details

-

-

-

... More
6F HVAC POWER PANEL

1

-

-

... More
Incomer 200A 4P MCCB (25kA) TM Based O/C, S/C & E/F Release-1No RYB on, off trip indication lamp -1 set. C.T.200/1A, CLASS 0.5 10VA- 1set. Type-2 SPD 25KA-1 no Multi Function Meter with RS 485 -1 no. Busbars: 200A 4P Cu Busbars: (25kA),1Sec Outgoing : 63A 4P MCCB TM based O/C & S/C Release (25kA) -4 nos. C.T.63/1A, CLASS 1.0 10VA- 4 set 40A 4P MCCB TM based O/C & S/C Release (25kA) -12 nos. C.T.40/1A, CLASS 1.0 10VA- 12sets. Multi Function Meter with RS 485-16 nos Please refer to single line diagram and technical specification for more details.

-

-

-

... More
7F MAIN POWER PANEL

1

-

-

... More
Incomer 400A 4P Onload Manual Changeover switch-1no 400A 4P MCCB (25kA) MP Based O/C, S/C & E/F Release-1No RYB on, off trip indication lamp -1 set. C.T.400/1A, CLASS 0.5 10VA- 1set. Type-2 SPD 25KA-1 nos Multi Function Meter with RS 485 -1 no. On, off indication lamp - 2sets. Busbars: 400A 4P Cu Busbars: (25kA),1Sec Outgoing : 125A 4P MCCB TM based O/C & S/C Release (25kA) -11nos. C.T.125/1A, CLASS 1.0 10VA- 11 set 200A 4P MCCB TM based O/C & S/C Release (25kA) -2 nos. C.T.200/1A, CLASS 1.0 10VA- 2 set Multi Function Meter with RS 485-13 nos Please refer to single line diagram and technical specification for more details

-

-

-

... More
7F HVAC POWER PANEL

1

-

-

... More
Incomer 200A 4P MCCB (25kA) TM Based O/C, S/C & E/F Release-1No RYB on, off trip indication lamp -1 set. C.T.200/1A, CLASS 0.5 10VA- 1set. Type-2 SPD 25KA-1 no Multi Function Meter with RS 485 -1 no. Busbars: 200A 4P Cu Busbars: (25kA),1Sec Outgoing : 63A 4P MCCB TM based O/C & S/C Release (25kA) -4 nos. C.T.63/1A, CLASS 1.0 10VA- 4 set 40A 4P MCCB TM based O/C & S/C Release (25kA) -12 nos. C.T.40/1A, CLASS 1.0 10VA- 12sets. Multi Function Meter with RS 485-16 nos Please refer to single line diagram and technical specification for more details.

-

-

-

... More
8F MAIN POWER PANEL

1

-

-

... More
Incomer 400A 4P Onload Manual Changeover switch-1no 400A 4P MCCB (25kA) MP Based O/C, S/C & E/F Release-1No RYB on, off trip indication lamp -1 set. C.T.400/1A, CLASS 0.5 10VA- 1set. Type-2 SPD 25KA-1 no Multi Function Meter with RS 485 -1 no. On, off indication lamp - 2sets. Busbars: 400A 4P Cu Busbars: (25kA),1Sec Outgoing : 125A 4P MCCB TM based O/C & S/C Release (25kA) -8nos. C.T.125/1A, CLASS 1.0 10VA- 8 set 40A 4P MCCB TM based O/C & S/C Release (25kA) -3 nos. C.T.40/1A, CLASS 1.0 10VA- 3 sets Multi Function Meter with RS 485-11nos Please refer to single line diagram and technical specification for more details

-

-

-

... More
8F HVAC POWER PANEL

1

-

-

... More
Incomer 125A 4P MCCB (25kA) TM Based O/C, S/C & E/F Release-1No RYB on, off trip indication lamp -1 set. C.T.125/1A, CLASS 0.5 10VA- 1set. Type-2 SPD 25KA-1 nos Multi Function Meter with RS 485 -1 no. On, off trip indication lamp - 1set. Busbars: 125A 4P Cu Busbars: (25kA) Outgoing : 40A TPN MCCB TM based O/C & S/C Release (25kA) -8 nos. C.T.40/1A, CLASS 1.0 10VA- 8set Multi Function Meter with RS 485- 8 nos Please refer to single line diagram and technical specification for more details

-

-

-

... More
9F MAIN POWER PANEL

1

-

-

... More
Incomer 400A 4P Onload Manual Changeover switch-1no 400A 4P MCCB (25kA) MP Based O/C, S/C & E/F Release-1No RYB on, off trip indication lamp -1 set. C.T.400/1A, CLASS 0.5 10VA- 1set. Type-2 SPD 25KA-1 no Multi Function Meter with RS 485 -1 no. On, off indication lamp - 2sets. Busbars: 400A 4P Cu Busbars: (25kA),1Sec Outgoing : 125A 4P MCCB TM based O/C & S/C Release (25kA) -8nos. C.T.125/1A, CLASS 1.0 10VA- 8 set 40A 4P MCCB TM based O/C & S/C Release (25kA) -3 nos. C.T.40/1A, CLASS 1.0 10VA- 3 sets Multi Function Meter with RS 485-11nos Please refer to single line diagram and technical specification for more details

-

-

-

... More
9F HVAC POWER PANEL

1

-

-

... More
Incomer 125A 4P MCCB (25kA) TM Based O/C, S/C & E/F Release-1No RYB on, off trip indication lamp -1 set. C.T.125/1A, CLASS 0.5 10VA- 1set. Type-2 SPD 25KA-1 nos Multi Function Meter with RS 485 -1 no. On, off trip indication lamp - 1set. Busbars: 125A 4P Cu Busbars: (25kA) Outgoing : 40A TPN MCCB TM based O/C & S/C Release (25kA) -8 nos. C.T.40/1A, CLASS 1.0 10VA- 8set Multi Function Meter with RS 485- 8 nos Please refer to single line diagram and technical specification for more details

-

-

-

... More
10F MAIN POWER PANEL

1

-

-

... More
Incomer 400A 4P Onload Manual Changeover switch-1no 400A 4P MCCB (25kA) MP Based O/C, S/C & E/F Release-1No RYB on, off trip indication lamp -1 set. C.T.400/1A, CLASS 0.5 10VA- 1set. Type-2 SPD 25KA-1 no Multi Function Meter with RS 485 -1 no. On, off indication lamp - 2sets. Busbars: 400A 4P Cu Busbars: (25kA),1Sec Outgoing : 125A 4P MCCB TM based O/C & S/C Release (25kA) -8nos. C.T.125/1A, CLASS 1.0 10VA- 8 set 40A 4P MCCB TM based O/C & S/C Release (25kA) -3 nos. C.T.40/1A, CLASS 1.0 10VA- 3 sets Multi Function Meter with RS 485-11nos Please refer to single line diagram and technical specification for more details

-

-

-

... More
10F HVAC POWER PANEL

1

-

-

... More
Incomer 125A 4P MCCB (25kA) TM Based O/C, S/C & E/F Release-1No RYB on, off trip indication lamp -1 set. C.T.125/1A, CLASS 0.5 10VA- 1set. Type-2 SPD 25KA-1 nos Multi Function Meter with RS 485 -1 no. On, off trip indication lamp - 1set. Busbars: 125A 4P Cu Busbars: (25kA) Outgoing : 40A TPN MCCB TM based O/C & S/C Release (25kA) -8 nos. C.T.40/1A, CLASS 1.0 10VA- 8set Multi Function Meter with RS 485- 8 nos Please refer to single line diagram and technical specification for more details

-

-

-

... More
11F MAIN POWER PANEL

1

-

-

... More
Incomer 400A 4P Onload Manual Changeover switch-1no 400A 4P MCCB (25kA) MP Based O/C, S/C & E/F Release-1No RYB on, off trip indication lamp -1 set. C.T.400/1A, CLASS 0.5 10VA- 1set. Type-2 SPD 25KA-1 no Multi Function Meter with RS 485 -1 no. On, off indication lamp - 2sets. Busbars: 400A 4P Cu Busbars: (25kA),1Sec Outgoing : 125A 4P MCCB TM based O/C & S/C Release (25kA) -8nos. C.T.125/1A, CLASS 1.0 10VA- 8 set 40A 4P MCCB TM based O/C & S/C Release (25kA) -3 nos. C.T.40/1A, CLASS 1.0 10VA- 3 sets Multi Function Meter with RS 485-11nos Please refer to single line diagram and technical specification for more details

-

-

-

... More
11F HVAC POWER PANEL

1

-

-

... More
Incomer 125A 4P MCCB (25kA) TM Based O/C, S/C & E/F Release-1No RYB on, off trip indication lamp -1 set. C.T.125/1A, CLASS 0.5 10VA- 1set. Type-2 SPD 25KA-1 nos Multi Function Meter with RS 485 -1 no. On, off trip indication lamp - 1set. Busbars: 125A 4P Cu Busbars: (25kA) Outgoing : 40A TPN MCCB TM based O/C & S/C Release (25kA) -8 nos. C.T.40/1A, CLASS 1.0 10VA- 8set Multi Function Meter with RS 485- 8 nos Please refer to single line diagram and technical specification for more details

-

-

-

... More
12F MAIN POWER PANEL

1

-

-

... More
Incomer 400A 4P Onload Manual Changeover switch-1no 400A 4P MCCB (25kA) MP Based O/C, S/C & E/F Release-1No RYB on, off trip indication lamp -1 set. C.T.400/1A, CLASS 0.5 10VA- 1set. Type-2 SPD 25KA-1 no Multi Function Meter with RS 485 -1 no. On, off indication lamp - 2sets. Busbars: 400A 4P Cu Busbars: (25kA),1Sec Outgoing : 125A 4P MCCB TM based O/C & S/C Release (25kA) -8nos. C.T.125/1A, CLASS 1.0 10VA- 8 set 40A 4P MCCB TM based O/C & S/C Release (25kA) -3 nos. C.T.40/1A, CLASS 1.0 10VA- 3 sets Multi Function Meter with RS 485-11nos Please refer to single line diagram and technical specification for more details

-

-

-

... More
12F HVAC POWER PANEL

1

-

-

... More
Incomer 125A 4P MCCB (25kA) TM Based O/C, S/C & E/F Release-1No RYB on, off trip indication lamp -1 set. C.T.125/1A, CLASS 0.5 10VA- 1set. Type-2 SPD 25KA-1 nos Multi Function Meter with RS 485 -1 no. On, off trip indication lamp - 1set. Busbars: 125A 4P Cu Busbars: (25kA) Outgoing : 40A TPN MCCB TM based O/C & S/C Release (25kA) -8 nos. C.T.40/1A, CLASS 1.0 10VA- 8set Multi Function Meter with RS 485- 8 nos Please refer to single line diagram and technical specification for more details

-

-

-

... More
Supply, Installation, testing & Commissioning of following MCB/ MCCB breaker with O/L, S/C & E/F protections in suitable sheet steel enclosure for local isolation with Phase LED lamp & Breaker ON/OFF/Trip (R/Y/B/R/G). Note: For 630A rating breaker shall be provided with floor mounted type enclosure with enough space for termination of incoming & outgoing cables, necessary mounting arrangements as required.

-

-

-

... More
100A 25kA 4P MCCB (INDOOR IP42)

2

-

-

... More
63A 25kA 4P MCCB (INDOOR IP42)

2

-

-

... More
200A 25kA 4P MCCB (INDOOR IP42)

1

-

-

... More
400A 36kA 4P MCCB (OUTDOOR IP55)

2

-

-

... More
630A 50kA 4P MCCB (INDOOR IP42)

4

-

-

... More
Supply, Installation, testing & Commissioning of following TP/4P MCB/RCBO 10kA breaker in suitable sheet steel enclosure for local isolation with enough space for termination of incoming & outgoing cables, necessary mounting arrangements as required.

-

-

-

... More
32A TP MCB (INDOOR IP 42 )

10

-

-

... More
63A TP MCB (INDOOR IP 42 )

5

-

-

... More
32A TP MCB (OUTDOOR IP 55)

25

-

-

... More
63A TP MCB (OUTDOOR IP 55)

10

-

-

... More
40A 4P MCB (INDOOR IP 42 )

5

-

-

... More
63A 4P MCB (INDOOR IP 42 )

5

-

-

... More
40A 4P RCBO 100mA (OUTDOOR IP 55)

5

-

-

... More
63A 4P RCBO 100mA (OUTDOOR IP 55)

5

-

-

... More
RISING MAIN

-

-

-

... More
Supply, Installation, Testing and Commissioning of 2500 A, 4P 50kA 1 sec Copper Sandwich Type Rising Mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply with metal clad enclosure having IP55 rating after fixing the tap off boxes and all accessories, made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos Copper bus bars , necessary joints, elbow joints & expansion joints and bends, fire barrier at each floor, provision of tapping at every metre, adopter box and copper flexible for joints, continuous earthing with 2 Nos GI strip of suitable size (one on each side) including, G.I. clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing system, supports etc. as required. The rate shall be included of wall frame assembly, all the supports, angles etc. Note: The rate shall be included 2RX50X10mm GI. flat for Earth busbar. The maximum hot spot temperature at any point in the bus bar at the continuous rated current shall not exceed 55deg above the maximum ambient temperature as per the site location.

130

-

-

... More
END FEED UNIT : Supplying, installation, testing & commisioning of 2500A 50kA 4P EDO ACB with O/C, S/C, E/F release SC for 1 sec End Feed Unit for the existing Sandwich type bus trunking/ rising mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick steel sheet enclosure (IP42) duly powder coated with ACB complete with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system, with all fixing accessories etc. as required. Separate cable alley need to be considered for Busduct connections or cable termination considering the cable bending radius.

2

-

-

... More
Tap off Boxes

-

-

-

... More
Supplying, installation, testing & commisioning of Tap-off boxes with 400A, 36kA 4P MP based MCCB with O/L,S/C releases. Separate cable alley need to be considered for cable termination considering the cable bending radius.

40

-

-

... More
Supplying, installation, testing & commisioning of Tap-off boxes with 125A, 36kA 4P TM based MCCB with O/L,S/C releases. Separate cable alley need to be considered for cable termination considering the cable bending radius.

4

-

-

... More
Supplying, installation, testing & commisioning of Tap-off boxes with 630A, 36kA 4P MP based MCCB with O/L,S/C releases. Separate cable alley need to be considered for cable termination considering the cable bending radius.

4

-

-

... More
Supplying, installation, testing & commisioning of Tap-off boxes with 250A, 36kA 4P MP based MCCB with O/L,S/C releases. Separate cable alley need to be considered for cable termination considering the cable bending radius.

4

-

-

... More
Supplying, installation, testing & commisioning of Tap-off boxes with 160A, 36kA 4P TM based MCCB with O/L,S/C releases. Separate cable alley need to be considered for cable termination considering the cable bending radius.

2

-

-

... More
BUSDUCTS

-

-

-

... More
Design, Engineering, Manufacture, Supply, Testing , Commisioning of 4000 Amps 4P 55kA Sandwitch type Copper BUSDUCT with integral earth including submission of relevant data, inspection and testing at factory works, packing, transportation from MANUFACTURER works to site, including transportation from store/yard to site at the place of installation, handling equipment at site, unpacking, assembly, including mounting and wiring of loose parts supplied by equipment vendor,minor civil works, interconnection of shipping sections, installation of bus duct support (fixing to wall/column/ceiling or steel structures) and aligning, levelling, grouting, testing, and calibration of equipment, including all labour and materials, as per approved drawings, specification of this tender and directions of Engineer-in-charge along with its necessary accessories. The bus duct shall be with IP 55 without any additional enclosure. The busduct should have two seperate runs of external earth busbar which should have half the size of phase busbar and suitable support from ceiling as per the detailed specification enclosed. The busduct should be with straight run, 90 deg. horizontal and Vertical bends, busbar trunking fittings (elbow, tees, End (Cable) feed Box, end covers, horizontal fixing devices, required Phase crioss over chambers,Terminal box at switchgear end including seal off bushing and Aluminium flexible and required accessories, Hot dip galvanised steel Bus duct support required as per site requirement. etc. The horizontal runs of busbar trunking system shall be supported by hangers at every 2 metre. Vertical runs of busbar trunking system shall be supported by hangers not more than 4m apart. Outdoor external canopy is required only for out door busdcuts as required as per site conditions. (From Transformer to Main Panel & DG to DG sync paenls & DG Sync panel to Main Panel/Tie breaker panel & Tie breaker panel to Main Panel).

580

-

-

... More
SINGLE ACB PANEL Supplying, installation, testing & commisioning of 4000A 55kA 4P EDO ACB Panel with provision of suitable size bus bars for Incomming cable of suitable runs to suffice the load requirements and outgoing Bus Duct connections with O/C, S/C, E/F release SC for 1 sec as Isoaltor Unit made with 2mm thick steel sheet enclosure (IP55) duly powder coated with ACB complete with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system, with all fixing accessories etc. as required. Separate cable alley need to be considered for cable termination considering the cable bending radius.

3

-

-

... More
MCB DISTRIBUTION BOARDS

-

-

-

... More
Supply, Installation, Testing and Commissioning of MCCB/ MCB Distribution board as per approved installation dwgs. Wall mounted MCCB/ MCB DBs with MS wire way box on top / bottom & on sides. MCBs shall be rated for 10kA with current limiting feature. Dummy ways to be covered with blank plates. All out going ways shall be labelled & laminated. Enclosure:1.2mm CRCA Sheet Steel, Powder Coated Door : Double Door Protection : IP 42 for Indoor / IP55 for out door Cable Entry : Top & Bottom Fixing Support - Indoor required clamps / Outdoor with required MS supports of Operating height at 1.2 mtr For UPS distribution RCBO`s shall be harmonic resistant (HI/SI type) Bus bar : Shall be tinned Copper and 200% rating for UPS DB Neutral Link MCB's : 10kA 'C' Curve for Lighting, Emergency Lighting & Raw power, 10kA 'D' Curve for UPS Power Distribution Note: 1) Separate Earth bus/Neutral bus for each phase 2) Each Circuit shall have yellow ferrules with circuit number 3) Accessories required for installation of DB's on Wall/Column/Gyp Board shall be considered 4) DB's shall be covered with powder coated (paint should match with DB Color) wire ways all around and up to ceiling to receive incoming circuits, how ever raceway shall be considered as a separate items 5) Laminated A3 OR A4 size SLD copy shall be pasted inside DB door 6) Safe shroud for Neutral link shall be provided

-

-

-

... More
External Lighting Distribution Board Supply, Installation, Testing and Commissioning of Three phase, Fabricated Indoor 8way VTPN Type DB, TPN Vertical bus bar type, Double door , IP 42 powder coated DB comprising of "C" curve MCB's for External Lighting Incomer - 63A 4P MCCB with 63A TP Power contact, 24h timer, ON, OFF Indication lamp, Push button (Start/Stop), 1No. of Auto/Manual selector switch with TB & necessary control protection etc. - 1 No Outgoings - 32A/25A TP MCB - 8Nos. Including all interconnections and other associated fixing accessories etc as reqd as per the site conditions.

1

-

-

... More
External Lighting Distribution Board Supply, Installation, Testing and Commissioning of Three phase, Fabricated Outdoor 8way VTPN Type DB, TPN Vertical bus bar type, Double door , IP 55 powder coated DB comprising of "C" curve MCB's for External Lighting Incomer - 63A 4P MCCB with 63A TP Power contact, 24h timer, ON, OFF Indication lamp, Push button (Start/Stop), 1No. of Auto/Manual selector switch with TB & necessary control protection etc. - 1 No Outgoings - 32A/25A TP MCB - 6Nos. Outgoings - 16A SP MCB - 18Nos. Including all interconnections and other associated fixing accessories etc as reqd as per the site conditions.

1

-

-

... More
Emergency Lighting DIstribution Board. Supply, Installation, Testing and Commissioning of 7 segment three phase, phase segregated, compartmentalised 6 way MCB DB Double door type, IP 42 powder coated comprising of "C" curve MCB's for LIGHTING DB. Including all fixing hardwares - Type - 3 Incomer - 40A 4P MCB - 1 No Phase Incomer - 40A 30mA DP RCBO - 3Nos Outgoings - 10A SP MCB - 18 Nos Including all interconnections and other associated fixing accessories etc as reqd as per the site conditions

13

-

-

... More
Lighting DIstribution Board. Supply, Installation, Testing and Commissioning of 7 segment three phase, phase segregated, compartmentalised 8 way MCB DB Double door type, IP 42 powder coated comprising of "C" curve MCB's for LIGHTING DB. Including all fixing hardwares Type - 1 Incomer - 40A 4P MCB - 1 No Phase Incomer - 40A 30mA DP RCBO - 3Nos Outgoings - 10A SP MCB - 24 Nos Including all interconnections and other associated fixing accessories etc as reqd as per the site conditions

18

-

-

... More
Power Distribution Board Supply, Installation, Testing and Commissioning of 7 segment three phase, phase segregated, compartmentalised 8 way MCB DB Double door type, IP 42 powder coated comprising of "C" curve MCB's for POWER DB. Incommer - 63A 4P MCB - 1 No Phase Incomer - 63A 100mA DP RCBO - 3Nos Outgoings - 16A/20A SP MCB - 24Nos Including all interconnections and other associated fixing accessories etc as reqd as per the site conditions

18

-

-

... More
UPS DB Supply, Installation, Testing and Commissioning of 7 segment three phase, phase segregated, compartmentalised 8 way MCB DB Double door type, IP 42 powder coated comprising of "D" curve MCB's for UPSDB. Incomer - 40A 4P MCB - 1 No Phase Incomer - 40A 100mA DP RCBO - 3Nos Outgoings - 16A SP MCB 'D' Curve - 24Nos Including all interconnections and other associated fixing accessories etc as reqd as per the site conditions.

17

-

-

... More
Kitchen VTPN DB Supply, Installation, Testing and Commissioning of Three phase, 16 Way VTPN MCCB DB Double door type, IP 42 powder coated comprising of "C" curve MCB's for KITCHEN VTPN DB Incomer - 125A 4P MCCB - 1 No Outgoings - 63A TP MCB - 4 Nos Outgoings - 40A TP MCB - 8 Nos Outgoings - 16A SP MCB - 12Nos Including all interconnections and other associated fixing accessories etc as reqd as per the site conditions

2

-

-

... More
HVAC / Power Distribution Board Supply, Installation, Testing and Commissioning of 7 segment three phase, phase segregated, compartmentalised 4 way MCB DB Double door type, IP 42 powder coated comprising of "C" curve MCB's for POWER DB. Incomer - 40A 4P MCB - 1 No Phase Incomer - 40A 100mA DP RCBO - 3Nos Outgoings - 16A SP MCB - 12Nos Including all interconnections and other associated fixing accessories etc as reqd as per the site conditions.

13

-

-

... More
Tenant VTPN DB Supply, Installation, Testing and Commissioning of Three phase,4 Way VTPN MCCB DB Double door type, IP 42 powder coated comprising of "C" curve MCB's for Tenant VTPN DB Incomer - 125A 4P MCCB with E/F - 1 No Outgoings - 63A TP MCB - 3 Nos & 40A TP MCB - 1 No Including all interconnections and other associated fixing accessories etc as reqd as per the site conditions

59

-

-

... More
Cafe Counter VTPN Power DB Supply, Installation, Testing and Commissioning of Three phase, 8 Way VTPN MCB DB Double door type, IP 42 powder coated comprising of "C" curve MCB's for Cafe Counter VTPN DB Incomer - 63A 4P MCB - 1 No Outgoings - 20A TP MCB - 4 Nos Outgoings - 16A SP MCB - 12 Nos Including all interconnections and other associated fixing accessories etc as reqd as per the site conditions

7

-

-

... More
Cafe Area VTPN Power DB Supply, Installation, Testing and Commissioning of Three phase, 8 Way VTPN MCCB DB Double door type, IP 42 powder coated comprising of "C" curve MCB's for Cafe Area VTPN DB Incomer - 125A 4P MCCB - 1 No Outgoings - 40A TP MCB - 4 Nos Outgoings - 16A SP MCB - 12 Nos Including all interconnections and other associated fixing accessories etc as reqd as per the site conditions

1

-

-

... More
SPN DB -1 Supply, Installation, Testing and Commissioning of Single phase, compartmentalised 12 way SPNDB Single door type, IP 42 powder coated comprising of "C" curve MCB's for DB. Phase Incomer - 40A 30mA DP RCBO - 1Nos Outgoings - 10A SP MCB - 10 Nos Including all interconnections and other associated fixing accessories etc as reqd as per the site conditions.

10

-

-

... More
SPN DB -2 Supply, Installation, Testing and Commissioning of Single phase, compartmentalised 8 way SPNDB Single door type, IP 42 powder coated comprising of "C" curve MCB's for DB. Phase Incomer - 40A 30mA DP RCBO - 1Nos Outgoings - 10A SP MCB - 6 Nos Including all interconnections and other associated fixing accessories etc as reqd as per the site conditions.

7

-

-

... More
VTPN Power DB Supply, Installation, Testing and Commissioning of Three phase, 12 Way VTPN MCB DB Double door type, IP 42 powder coated comprising of "D" curve MCB's for Cafe Counter VTPN DB Incomer - 100A 4P MCB - 1 No Outgoings - 32A SP MCB - 24 Nos Outgoings - 32A TP MCB - 4 Nos Including all interconnections and other associated fixing accessories etc as reqd as per the site conditions

2

-

-

... More
VTPN Power DB Supply, Installation, Testing and Commissioning of Three phase, 8 Way VTPN MCB DB Double door type, IP 42 powder coated comprising of "D" curve MCB's for Cafe Counter VTPN DB Incomer - 100A 4P MCB - 1 No Outgoings - 32A SP MCB - 18 Nos Outgoings - 32A TP MCB - 2 Nos Including all interconnections and other associated fixing accessories etc as reqd as per the site conditions

2

-

-

... More
LT POWER CABLES

-

-

-

... More
Supply, loading, transportation unloading and storages at site , shifting from storage place to site of following sizes of XLPE insulated PVC sheathed,FRLSH, Aluminium/Copper conductor armoured/Unarmoured power/control cable of 1.1 KV grade conforming to IS amended upto date and as per specifications.All cables shall be tagged. Cables shall be laid on trays, ceilings, walls trenches, ground etc., with necessary clamps, cable ties, fasteners, identification tags, cable marking as required. The Quantities given in the BOQ are only approximate and the contractor has to take actual measurements at site for the exact quantities of materials required before purchase of materials required for the work.

-

-

-

... More
3.5 C X 400 sqmm A2XFY

2450

-

-

... More
3.5 C X 300 sqmm A2XFY

2280

-

-

... More
3.5 C X 240 sqmm A2XFY

730

-

-

... More
3.5 C X 185 sqmm A2XFY

30

-

-

... More
3.5 C X 150 sqmm A2XFY

190

-

-

... More
3.5 C X 120 sqmm A2XFY

300

-

-

... More
3 C X 95 sqmm A2XFY

1108

-

-

... More
3.5 C X 50 sqmm A2XFY

2603

-

-

... More
3.5 C X 35 sqmm A2XFY

45

-

-

... More
3.5 C X 95 sqmm A2XFY

570

-

-

... More
4C X 25 sqmm A2XFY

490

-

-

... More
4C X 16 sqmm A2XFY

1890

-

-

... More
3CX6sq.mm 2XWY

1300

-

-

... More
3CX10sq.mm 2XWY

385

-

-

... More
3CX16sq.mm 2XWY

80

-

-

... More
4CX6sq.mm 2XWY

5135

-

-

... More
4CX10sq.mm 2XWY

4950

-

-

... More
4CX16sq.mm 2XWY

334

-

-

... More
4CX25sq.mm 2XWY

50

-

-

... More
3CX4sq.mm 2XWY

2230

-

-

... More
1C X 95 sqmm Copper flexible cable

110

-

-

... More
1C X 35 sqmm Copper flexible cable

110

-

-

... More
1C X 25 sqmm Copper flexible cable

50

-

-

... More
1C X 16 sqmm Copper flexible cable

100

-

-

... More
1C X 10 sqmm Copper flexible cable

100

-

-

... More
1C X 6 sqmm Copper flexible cable

250

-

-

... More
1C X 4 sqmm Copper flexible cable

250

-

-

... More
3C X 2.5 sqmm Copper flexible cable

200

-

-

... More
3C X 4 sqmm Copper flexible cable

500

-

-

... More
3C X 6 sqmm Copper flexible cable

200

-

-

... More
4CX2.5 sq.mm 2XWY

200

-

-

... More
3C X 70 sqmm 2XWY

50

-

-

... More
FIRE SURVIVAL CABLES,

-

-

-

... More
Supply, loading, transportation unloading and storages at site , shifting from storage place to site of following sizes of XLPE insulated PVC sheathed,FireSurvival (FS), Aluminium/Copper conductor armoured power cable of 1.1 KV grade conforming to IS amended upto date and as per specifications.All cables shall be tagged. The Quantities given in the BOQ are only approximate and the contractor has to take actual measurements at site for the exact quantities of materials required before purchase of materials required for the work

-

-

-

... More
4C X 300 sqmm Al. FS cables

1310

-

-

... More
4 C X 120 sqmm Al. FS cables

340

-

-

... More
4C X 95 sqmm Al. FS cables

20

-

-

... More
4 X 120 sqmm Cu. FS cables

20

-

-

... More
4C X 70 sqmm Cu. FS cables

20

-

-

... More
3CX10sq.mm Cu. FS cables

30

-

-

... More
3C X 6 sqmm Cu. FS cables

1050

-

-

... More
4C X 16 sqmm Cu. FS cables

370

-

-

... More
4C X 10 sqmm Cu. FS cables

120

-

-

... More
4C X 6 sqmm Cu. FS cables

50

-

-

... More
LT CABLES TERMINATIONS

-

-

-

... More
Supply & end termination of following AL/CU armoured power cables with necessary double compression brass glands, AL/CU. terminal sockets, insulation tapes, fasteners, earthing clips & connecting the clip to main earth bus with suitable bare copper wire complete accessories as required; all outdoor double compression and indoor single compression.

-

-

-

... More
3.5 C X 400 sqmm A2XFY

96

-

-

... More
3.5 C X 300 sqmm A2XFY

68

-

-

... More
3.5 C X 240 sqmm A2XFY

20

-

-

... More
3.5 C X 185 sqmm A2XFY

10

-

-

... More
3.5 C X 150 sqmm A2XFY

8

-

-

... More
3.5 C X 120 sqmm A2XFY

16

-

-

... More
3 C X 95 sqmm A2XFY

48

-

-

... More
3.5 C X 50 sqmm A2XFY

146

-

-

... More
3.5 C X 35 sqmm A2XFY

2

-

-

... More
3.5 C X 95 sqmm A2XFY

6

-

-

... More
4C X 25 sqmm A2XFY

20

-

-

... More
4C X 16 sqmm A2XFY

46

-

-

... More
3CX6sq.mm 2XWY

39

-

-

... More
3CX10sq.mm 2XWY

29

-

-

... More
3CX16sq.mm 2XWY

4

-

-

... More
4CX6sq.mm 2XWY

164

-

-

... More
4CX10sq.mm 2XWY

274

-

-

... More
4CX16sq.mm 2XWY

12

-

-

... More
4CX25sq.mm 2XWY

50

-

-

... More
3CX4sq.mm 2XWY

50

-

-

... More
1C X 95 sqmm Copper flexible cable

18

-

-

... More
1C X 35 sqmm Copper flexible cable

18

-

-

... More
1C X 25 sqmm Copper flexible cable

4

-

-

... More
1C X 16 sqmm Copper flexible cable

6

-

-

... More
1C X 10 sqmm Copper flexible cable

6

-

-

... More
1C X 6 sqmm Copper flexible cable

30

-

-

... More
1C X 4 sqmm Copper flexible cable

30

-

-

... More
3C X 2.5 sqmm Copper flexible cable

20

-

-

... More
3C X 4 sqmm Copper flexible cable

50

-

-

... More
3C X 6 sqmm Copper flexible cable

30

-

-

... More
4CX2.5 sq.mm 2XWY

2

-

-

... More
3C X 70 sqmm 2XWY

10

-

-

... More
Fire Survival -Cable End Termination

-

-

-

... More
Supplying and making Flame Proof end termination with brass double compression Flame Proof gland and Aluminium/ copper lugs for following size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required.

-

-

-

... More
4C X 300 sqmm Al. FS cables

30

-

-

... More
4 C X 120 sqmm Al. FS cables

4

-

-

... More
4 C X 95 sqmm Al. FS cables

2

-

-

... More
4C X 120 sqmm Cu. FS cables

2

-

-

... More
4C X 70 sqmm Cu. FS cables

2

-

-

... More
3CX10sq.mm Cu. FS cables

2

-

-

... More
3C X 6 sqmm Cu. FS cables

42

-

-

... More
4C X 16 sqmm Cu. FS cables

24

-

-

... More
4C X 10 sqmm Cu. FS cables

24

-

-

... More
4C X 6 sqmm Cu. FS cables

4

-

-

... More
LUMINAIRES

-

-

-

... More
Supply,Installation, testing & commissioning of following types of light fixture complete with driver, Mirror optic reflectors, louvers, inter connecting wires, terminals, lamps,connectors etc, fixing on the wall / ceiling/false ceiling with wooden blocks, screws, hardware's, suspended chain hooks., rate shall include necessary supporting / suspending hardware.The support requirement shall be as per site requirement.. The hardware viz., anchor fasteners, suspending GI chains, down rods will not be measured seperately. Note: Samples should be submitted for light fixture model and Lamp Colour tempature (CCT) for approval of PMC / Employer.

-

-

-

... More
Ceiling mounted downlight with system power: 15 W, Luminous flux of luminaire 1350 lm, Colour temperature of 4000 K, Neutral white, CRI 80, 230 V constant current driver, 70% of luminous flux after 50,000 operating hours; Energy efficient LED, Direct light emission, Luminaire housing in aluminium, polyester powder black coloured coat applied over a 5- stage pre-treatment, opal diffuser for uniform illumination, ZHLS (ZERO HALOGEN LOW SMOKE) internal wiring, Electronic control gearProtection class I, IP 20, Ø = 100 mm, H = 165 mm. (TYPE-1)

110

-

-

... More
4 feet - PVC Batten with integrated LED tube 22W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. (TYPE-2)

66

-

-

... More
Integral, SMD LED, IP40, 36/40W Surface Mounted LED Batten with System efficacy of more than 110 lm/W. LED luminaire shall have sleek designwith Extruded Aluminum Section. The luminaire shall have High Optically Efficient Polycarbonate Diffuser for Uniform illumination and wider light distribution. Screwless Design ensures ease of maintenance. The LEDs used should be with CCT of 5700 K and CRI of Minimum 80. LED Driver shall be Isolated type, Constant Current topology driver with proper heat sink for heat dissipation suitable to operate in input voltage range of 150V to 270V (nominal rated voltage – 240V) with 3 KV internal surge protection, Power factor greater than 0.95 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire. (TYPE-3)

40

-

-

... More
Wall / Surface / Ceiling Mounted luminaire with HPE (High Performance Efficiency) LED (Light Emitting Diode) system power: 26 W, Luminous flux of luminaire 4680 lm,Colour temperature of 4000 K, Neutral white, CRI 80, 230 V constant current driver, 70% of luminous flux after 50,000 operating hours; Energy efficient LEDs, Direct light emission, Luminaire profile in anodised aluminium, snap fit linear prismatic diffuser for a homogenous light distribution, ZHLS (ZERO HALOGEN LOW SMOKE) internal wiring, Electronic control gear, Protection class I, IP 40, L = 1188 mm, B = 65 mm, H = 42 mm, PL max = 1500 mm. (TYPE-4)

220

-

-

... More
Flexible Strip luminaire with LED system power: 12W/m, luminous flux of luminaire 540lm/m,colour temperature of 3000K, beam angle of 160°, CRI80, 230Vconstant current driver, 70% of luminous flux after50,000 operating hours; energy effcient LEDs, direct lightemission, support profile in powder coated white, Electroniccontrol gear, Protection class I, IP68,L=1000mm, B = 16mm, H = 12mm. BIS Approved with 2 years Warranty against any manufacturing defect working under standard electrical condition. (TYPE-5)

50

-

-

... More
IP65 LED bulkhead luminaire with special application luminaire shall be designed to provide undisrupted lighting for dusty and humid indoor application. The luminaire shall be with all-weather polycarbonate housing and highly efficient electronics with LED system to offer long useful life even in adverse application and environmental conditions. The luminaire shall be with pressure die cast aluminium housing. The system wattage shall be 15W with system lumens of 1200 lumens and system efficacy of 80 lm / W. LED make: that satisfies IEC62471 Photobiological/RoHS Standards with and LED Efficacy of 150lm/W, Colour Temperature-6500K or Higher with LED binning as per ANSI Bin C78.377A, 120Deg LED Beam Angle, CRI 80, Life of LED as per L70 50000burning hours, Ambient temp-0 to 50DegC, Driver efficiency85%, THD10%, Power factorB231 . (TYPE-6)

142

-

-

... More
LED Ceiling Mounted luminaire of 35W with Efficacy of 100lm Lumen: 3500 , CRI :80 , Color Temperature: 4000K SDCM 3 Life Time: L70 50000Hrs Material: Aluminium Optics: Prismatic Diffuser Finish: White Control Gear: Electronic Control Protection Class: I IP 54 Dia:0480mm H: 80mm, IP 54 (TYPE-7)

25

-

-

... More
IP65 4' LED luminaire with special application luminaire shall be designed to provide undisrupted lighting for dusty and humid indoor application. Surface mounted luminaire with HPE (High-Performance Efficiency) LED (Light Emitting Diode) system power: 36W, Luminous flux of luminaire 3960lm, Colour temperature of 4000K, Neutral white, CRI90, 230 V constant current driver, 70% of luminous flux after 50,000 operating hours; Energy efficient LEDs, Direct light emission, Luminaire housing in grey coloured polycarbonate with Opal diffuser with chrome steel clamps, ZHLS (ZERO HALOGEN LOW SMOKE) internal wiring, Electronic control gear Protection Class I, IP 65. L = 1220 mm, B = 80 mm, H = 69 mm.. (TYPE-8)

50

-

-

... More
LED Pendant mounted luminaire of 100W with Efficacy of 120lm Lumen,12000 CRI :80 Color Temperature: 4000K SDCM 3 Life Time: L70 50'000hrs 230V Light Throw: Direct light emission Material: Aluminium Optics: Clear Glass Finish: Black Control Gear: Electronic Control Protection Class: I IP 65 Dia:0300mm H: 170mm IP 65 .(TYPE-9)

65

-

-

... More
Supplying and fixing of LED Aviation light, suitable for upto 70 m height, epoxy flame orange painted die-cast aluminum alloy housing, with polycarbonate glass, bird spike including supplying and laying of 3 core weather proof PVC insulated and PVC sheathed copper conductor cable from ground.

3

-

-

... More
4 feet 36W Well glass Falme proof LED emergency light with required fixing accessories as required & Colour Temperature-6500K, CRI 80, Life of LED as per L70 50000burning hours, , Driver efficiency85%, THD10%, Power factor0.95, Driver Voltage range 140-270V AC and Safety Extra Low Voltage Safe level60V DC as per IEC standard, high voltage cutoff & auto restart @320V, phase to phase 440V protection upto 8hrs, Electrical Safety with Class 1 Insulation, Constant Current - Constant Voltage LED Driver with APFC Construction, Driver shall be compatible for auto cut off and restart with deviation to operating voltage also the ripple shall be less 5%. (TYPE-10)

10

-

-

... More
Supplying and fixing of flameproof 80 W LED Flood Light ,IP 66 Rated , Suitable for Zone 1 & ZOne 3 area application and II C Gas group with , Constant Current - Constant Voltage LED Driver , Driver shall be compatible for auto cut off and restart with deviation to operating voltage also the ripple shall be less 5%. (TYPE-11)

5

-

-

... More
Supplying and fixing of flameproof 100 W LED Flood Light ,IP 66 Rated , Suitable for Zone 1 & ZOne 3 area application and II C Gas group with , Constant Current - Constant Voltage LED Driver , Driver shall be compatible for auto cut off and restart with deviation to operating voltage also the ripple shall be less 5%. (TYPE-12)

5

-

-

... More
Surface mounted LED downlighter with system wattage not more than 18W and luminaire lumens not less than 2000 lumens. The system efficacy shall be 100 lm/W. The housing in die-cast aluminium with Opal protruded diffuser for better distribution of light. LED make: that satisfies IEC62471 Photobiological/RoHS Standards with and LED Efficacy of 150lm/W, Colour Temperature-4000K or Higher with LED binning as per ANSI Bin C78.377A, 120Deg LED Beam Angle, CRI 80, Life of LED as per L70 30000burning hours, Ambient temp-0 to 50DegC, Driver efficiency85%, THD10%, Power factor0.9, Inbuilt Surge protection in CM ≥ 2.5KV, LED Driver with Voltage range 150-270V AC. Driver shall be potted driver with BIS compliance. (TYPE-13)

114

-

-

... More
Switching PIR SensorsCeiling Mount 360 degree. Micro Detection - High Sensitivity Range 10 m Dia at height of 2.5 meter ( 7 m dia Micro Sensitivity 3 m macro) and . Current Capacity 10A. Digital Remote IR based Commissioning with hand held programmer for following Programmable features: OFF delay time 10 Sec - 96 hrs, photocell and power up (status of luminaires when power is applied). It shall have provision to manually override luminary ON/OFF status using hand held remote control.

52

-

-

... More
WIRING FOR LUMINAIRES

-

-

-

... More
CIRCUIT MAIN

-

-

-

... More
Supply, Laying, Testing and Commissioning of Wiring for Circuit/submains along with earth wire with 2R 2.5Sq.mm + 1R 2.5S.mm FRLS PVC insulated multistrand copper wire in surface /recessed MS conduit with all accessories as required as per site conditions. For concealed conduiting, wall chasing and finishing need to be considered in the quote. Conduit colour to be black in all closed ceiling and white in all open ceiling or as directed by PMC/Employer. Wire`s colour coding should be as per PMC/Employer in charge.

3800

-

-

... More
Supply, Laying, Testing and Commissioning of Wiring for Circuit/submains along with earth wire with 2R 2.5Sq.mm + 1R 2.5S.mm FRLS PVC insulated multistrand copper wire in surface /recessed medium class PVC conduit with all accessories as required as per site conditions. For concealed conduiting, wall chasing and finishing need to be considered in the quote. Wire`s colour coding should be as per PMC/Employer in charge.

980

-

-

... More
Supply, Laying, Testing and Commissioning of Wiring for submains along with earth wire with 2R 1.5Sq.mm + 1R 1.5S.mm FRLS PVC insulated multistrand copper wire in surface /recessed MS conduit with all accessories as required as per site conditions. For concealed conduiting, wall chasing and finishing need to be considered in the quote. Conduit colour to be black in all closed ceiling and white in all open ceiling or as directed by PMC/Employer. Wire`s colour coding should be as per PMC/Employer in charge.

1400

-

-

... More
LIGHT POINTS WIRING Supply, installation, Testing and Commissioning of switch control point wiring as describe in below line items . Conduit colour to be black in all closed ceiling and white in all open ceiling or as directed by PMC/Employer. Wire`s colour coding should be as per PMC/Employer in charge. Point wiring for lights to be with connectors & flexible drops to be with proper sockets Any conduits crossing partitions/walls should have appropriate sleeves with fire sealant (fire sealant shall be covered under relavant item) For concealed conduiting, wall chasing and finishing need to be considered in the quote.

-

-

-

... More
PRIMARY POINTS Supply, installation, Testing and Commissioning of point wiring with 2Rx1.5Sq.mm (Phase&Neutral) + 1Rx1.5Sq.mm (Earth) FRLS PVC insulated 1100V Copper wires in suitable surface/receesed Steel conduit including all accessories such as bends, junction boxes,ceiling roses etc., complete. The rate shall includes modular switch,modular front plate,suitable GI box and earthing etc as required. Consider Average Length for each point as - 10 Mtrs.(From SwitchBox to First Light Point ) .

350

-

-

... More
SECONDARY POINTS Supply, installation, Testing and Commissioning of Group controlled point wiring with 2Rx1.5Sq.mm (Phase&Neutral) + 1Rx1.5Sq.mm (Earth) FRLS PVC insulated 1100V Copper wires in suitable surface/receesed Steel conduit including all accessories such as bends, junction boxes,ceiling roses etc., complete. Consider Average Length foreach point as- 6Mtrs. (From Primary points to other Light Points) .

510

-

-

... More
Supply , Installation , Testing & Commisioining of Light & Power Wiring for Passenger Elevators (Ground to 12th Floor) comprising of following items mentioned below & Consider surface mounted conduiting with required all fixing accessories as required as per site conditions.The below mentioned item`s rates & quantity shall be considered from GF to 12 th Floors a. 12w LED Bulk Head - IP65 Protection b. 6A 3 Pin switched socket outlet c. Wiring for light points controlled by a 6A switch. d. Wiring for pit light using 2 Nos 6A 2 way switches. e. Wiring for sets of 6A switched & socket outlets. wire for lighting circuit : 3 runs of 1.5 sq.mm wire for power circuit : 3 runs of 4.0 sq.mm Conduit: 20mm steel Conduit for lighting & 25 mm dia steel Conduit for Power

10

-

-

... More
Elevator Shaft Lighting for Service Elevators (Ground to Terrace) comprising of following items mentioned below & Consider surface mounted conduiting with required all fixing accessories as required as per site conditions. Consider surface mounted conduiting. The rates & quantity of below mentioned items shall be considered from GF to 12 th Floors for 1no Lift. comprising of : - a. 12w LED Bulk Head - IP65 Protection b. 6A 3 Pin switched socket outlet c. Wiring for light points controlled by a 6A switch. d. Wiring for pit light using 2 Nos 6A 2 way switches. e. Wiring for sets of 6A switched & socket outlets. wire for lighting circuit : 3 runs of 1.5 sq.mm wire for power circuit : 3 runs of 4.0 sq.mm Conduit: 20mm steel Conduit for lighting & 25 mm dia steel Conduit for Power

2

-

-

... More
WIRING FOR POWER

-

-

-

... More
MAIN POWER WIRING

-

-

-

... More
Supply, Laying, Testing and Commisiosning of 2R 6Sqmm + 1R 6 Sq..mm PVC insulated FRLS multistrand copper wire in MS conduit with all accessories as required as per site conditions. For concealed conduiting, wall chasing and finishing need to be considered in the quote.

2134

-

-

... More
Supply, Laying, Testing and Commisiosning of 2R 4Sqmm + 1R 4Sq.mm PVC insulated FRLS multistrand copper wire in MS conduit with all accessories as required as per site conditions. For concealed conduiting, wall chasing and finishing need to be considered in the quote.

5940

-

-

... More
Supply, Laying, Testing and Commisiosning of 2R 2.5Sqmm + 1R 2.5Sq.mm PVC insulated FRLS multistrand copper wire in MS conduit with all accessories as required as per site conditions. For concealed conduiting, wall chasing and finishing need to be considered in the quote.

1920

-

-

... More
SWITCHES, SOCKETS & ACCESSORIES 'Supply, fixing, testing and commissioning of Modular Switch & Socket combination in suitable modular box with front plates ,blank plates,acessories wherever required and Industrial Sockets with MCB in Open/Recessed system with necessary earthing arrangements.The necessary civil works shall be done for connected works and no extra payment will be made for the same. (On non availability of specified rating industrial sockets, immediate higher rating socket must be provided with given control breakers). 'All modular type sockets shall be shuttered type with earth terminal. All industrial sockets should be provided with suitable plug. All metal box should be earthed as required & shall be covered with removable film coat to protect from scratches and paint.

-

-

-

... More
1No of 6A 240V 5pin Modular Socket Controlled by 6A Modular Switch with suitable size front plate and surface box / metal box in open / recessed system.

130

-

-

... More
2Nos of 6A 240V 5pin Modular Socket Controlled by 2 Nos 6A Modular Switch with suitable size front plate and surface box / metal box in open / recessed system.

42

-

-

... More
2Nos of 6/16A 240V 5pin Modular Socket Controlled by 2nos 16A Modular Switch with suitable size front plate and surface box / metal box in open / recessed system.

44

-

-

... More
1No of 6/16A 240V 5pin Modular Socket Controlled by 16A Modular Switch with suitable size front plate and surface box / metal box in open / recessed system.

398

-

-

... More
1No, Moulded type 6/16A socket & 16A switch shrouded with shuttered including connections earthing etc. with IP 66 rated enclosure made of polycarbonate outdoor box along with Adptor , PVC membrane etc.

15

-

-

... More
1No of 20A 240V 5/6pin Socket Controlled by 20A SP Switch with suitable size front plate and surface box / metal box in open / recessed system.(For Raw/UPS Power Socket).

10

-

-

... More
1No 20A 240V 3 pin industrial type polycarbonate plug & socket (IP65) with 20A DP 10kA MCB in a suitable size enclosure fixed in open / recessed system.

4

-

-

... More
1No 20A 240V 3 pin single phase Industrial type socket with plug top controlled by 20A DP MCB in a suitable size MS enclosure fixed in open / recessed system.

5

-

-

... More
1No. Of 16A 5 pin Three phase Industrial type socket with plug top controlled by 16A 4P MCB in a suitable size MS enclosure fixed in open / recessed system.

2

-

-

... More
Supply and installation of 1No. Of 32A 3 pin single phase Industrial type socket with plug top controlled by 32A DP MCB (D-curve) in a suitable size enclosure fixed in open / recessed system.

44

-

-

... More
Supplying and fixing 1 or 2 Module (75mmX75mm) size GI box alongwith modular base & cover plate for modular switches in recess etc. as required.

292

-

-

... More
Supplying and fixing 4 Module (125mmX75mm) size GI box along with modular base & cover plate for modular switches in recess etc. as required.

136

-

-

... More
Supplying and fixing 6 Module (200mmX75mm) size GI box along with modular base & cover plate for modular switches in recess etc. as required.

10

-

-

... More
Supplying and fixing 8 Module (125mmX125mm) size GI box along with modular base & cover plate for modular switches in recess etc. as required.

6

-

-

... More
Supplying and fixing 12Module (200mmX150mm) size GI box along with modular base & cover plate for modular switches in recess etc. as required.

4

-

-

... More
Supply, installation, connection, testing and commissioning of following size minimum IP-67 Water tight Junction box along with Terminal & including accessories for junction box like PVC grommet ,Entery Thread Metric,Lock Nuts etc. 130X180X77mm

60

-

-

... More
Supply, fixing, testing and commissioning of 3Nos of 10A universal socket controlled by 1 number of 16A switch and provision for 2Nos of RJ45 socket in suitable size POP UP Box (10M/12M) on table / floor with suitable Flush-mounting boxes for installation in table top / concrete floors, Colour shall be Brushed stainless steel finish and suitable metal back box, necessary earthing terminals provided at the back box and all other required accessories.

6

-

-

... More
LADDER CABLE TRAYS

-

-

-

... More
Supply & Installation of hot dip GI ladder type cable tray (galvanisation thickness not less than 80 microns) with all accessories like coupler,including supply and fixing of suitable supports (Including Anchor fastners) GI nut bolts,bend, tee, reducer etc as per specification and drawing with all necessary accessories as required for complete installation shall be included and complete with all required hardware, Contractor to provide shop drawing for cable tray : (Quoted cost shall include the cost towards cable tray supporting systems.) The support shall be as per site requirement.

-

-

-

... More
450 mm width X 100 mm depth X 2 mm thicknessv GI ladder type cable tray

30

-

-

... More
600 mm width X 100 mm depth X 2 mm thickness GI ladder type cable tray

170

-

-

... More
750 mm width X 100 mm depth X 2 mm thickness GI ladder type cable tray

280

-

-

... More
1000 mm width X 110 mm depth X 2 mm thickness GI ladder type cable tray

410

-

-

... More
PERFORATED CABLE TRAYS

-

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.

-

-

-

... More
100 mm width X 50 mm depth X 1.6 mm thickness

36

-

-

... More
150 mm width X 50 mm depth X 1.6 mm thickness

30

-

-

... More
225mm width X 50 mm depth X 1.6 mm thickness

5

-

-

... More
300 mm width X 50 mm depth X 1.6 mm thickness

85

-

-

... More
450 mm width X 62.5 mm depth X 2.0 mm thickness

12

-

-

... More
600 mm width X 62.5 mm depth X 2.0 mm thickness

18

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.

-

-

-

... More
100 mm width X 50 mm depth X 1.6 mm thickness

36

-

-

... More
150 mm width X 50 mm depth X 1.6 mm thickness

30

-

-

... More
225mm width X 50 mm depth X 1.6 mm thickness

5

-

-

... More
300 mm width X 50 mm depth X 1.6 mm thickness

85

-

-

... More
450 mm width X 62.5 mm depth X 2.0 mm thickness

12

-

-

... More
600 mm width X 62.5 mm depth X 2.0 mm thickness

18

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Cross member"(galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.

-

-

-

... More
100 mm width X 50 mm depth X 1.6 mm thickness

36

-

-

... More
150 mm width X 50 mm depth X 1.6 mm thickness

30

-

-

... More
225mm width X 50 mm depth X 1.6 mm thickness

5

-

-

... More
300 mm width X 50 mm depth X 1.6 mm thickness

85

-

-

... More
450 mm width X 62.5 mm depth X 2.0 mm thickness

12

-

-

... More
600 mm width X 62.5 mm depth X 2.0 mm thickness

18

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Reducer"(galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.

-

-

-

... More
100 mm width X 50 mm depth X 1.6 mm thickness

36

-

-

... More
150 mm width X 50 mm depth X 1.6 mm thickness

30

-

-

... More
225mm width X 50 mm depth X 1.6 mm thickness

5

-

-

... More
300 mm width X 50 mm depth X 1.6 mm thickness

85

-

-

... More
450 mm width X 62.5 mm depth X 2.0 mm thickness

12

-

-

... More
600 mm width X 62.5 mm depth X 2.0 mm thickness

18

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness 65 - 70 Micron as per IS2629) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including supports , G.I. bolts & nuts, etc. as required. as specified and shown on drawings. Up to 450mm - cable trays shall be supplied along with rod and C channel, refer specifications. Above 450mm cable tray support shall be with suitable angle supports as per specifications. The support shall be as per site requirement.(Quoted cost shall include the cost towards cable tray supporting systems.)

-

-

-

... More
100 mm width X 50 mm depth X 1.6 mm thickness

1085

-

-

... More
150 mm width X 50 mm depth X 1.6 mm thickness

905

-

-

... More
225mm width X 50 mm depth X 1.6 mm thickness

150

-

-

... More
300 mm width X 50 mm depth X 1.6 mm thickness

2576

-

-

... More
450 mm width X 62.5 mm depth X 2.0 mm thickness

360

-

-

... More
600 mm width X 62.5 mm depth X 2.0 mm thickness

520

-

-

... More
FLOOR RACEWAYS

-

-

-

... More
Supply and installation of pre-galvalized (galvanisation thickness not less than 80 microns) floor raceways made from 2.0mm thick G.I. sheet in following size for industrial power outlet wiring, ncluding supply and fixing of suitable supports (Including Anchor fastners) tele, data, etc complete with suitable knockouts, junction box, tap off points, reducer, 3mm /2.5mm/2 mm thick removable top cover and cable holding arrangement : (Quoted cost shall include the cost towards raceway supporting systems.) Raceway installed above false ceiling/floor shall include necessary mounting supports, junction boxes and accessories to fix it firmly to the ground/ ceiling. The raceways shall be fixed to the floor with GI/MS (25mm x 3mm) strips so that there is no movement of the channels when civil work (pouring of cement concrete) is being done. Rate includes necessary floor cutting and chipping with machine of minimum 50mm depth, removal of debris out of site and neatly finished with M15 grade concrete up to the finished floor level. Race ways to be covered with Chicken mesh before concreting. Curing compound to be applied after initial setting of the concrete.All edges, cut faces shall be free of burrs & shall be smooth. The channels shall be earthed at the boxes and at the joints with 14 SWG bare copper wire with screws so that earth is continuous. Jointing of the race ways to be done with welding.

-

-

-

... More
FLOOR JUNCTION BOXES

-

-

-

... More
160 x 160 x 50mm Size

10

-

-

... More
210 x 210 x 50mm Size

10

-

-

... More
FLOOR RACEWAYS

-

-

-

... More
150 x 40mm Size with one compartments and 2mm thick top cover.

30

-

-

... More
200 x 40mm Size with one compartments and 2mm thick top cover.

30

-

-

... More
CONDUITS /ACCESSORIES

-

-

-

... More
Supply and fixing of heavy duty PVC& steel conduit of various dia., exposed or concealed, with all accessories, Wall chasing, finishing, fish wire, junction boxes etc., as directed by the project incharge officers and the brand should got approval. (Exposed Conduiting - MS & Concealed Conduiting - PVC HMS )

-

-

-

... More
Supply and Fixing of 32mm PVC Conduits

600

-

-

... More
Supply and Fixing of 25mm PVC Conduits

2400

-

-

... More
Supply and Fixing of 20mm MS Conduits

720

-

-

... More
Supply and Fixing of 25mm MS Conduits

2050

-

-

... More
Supply and Fixing of 32mm MS Conduits

440

-

-

... More
Supply and arranging for Temporary Power Supply for Electrical power distribution on site for lighting , Power and other contract agencies at site including sufficiaent no of tube light fittings, sifficient no. of plug points with plug tops with adequate distribution boards with IP Rating and all other necessory safety devices like elcb, etc., to ensure safe and continued supply at site. up to end of the project. as directed by the departmental officers and the brand should be got approval.

1

-

-

... More
Supply & Installation of Double wall corrugated HDPE pipes of 6 Kg/Cm2 working pressure   including all accessories i.e. bends, reducers, flanges as required. of following sizes

-

-

-

... More
50 mm OD with 3.6 mm wall

50

-

-

... More
100 mm OD with 5.5 mm wall

300

-

-

... More
160 mm OD with 7.7 mm wall

50

-

-

... More
SHOP DRAWINGS, INSPECTION AND APPROVALS

-

-

-

... More
Preparation & submission of applications, Liasioning with TNEB for getting Load sanction, service connections all necessary co-ordination upto completion of the project.

1

-

-

... More
Preparation & submission of drawings for CEG approval , Getting the required statutory approval like CEIG, local statutory authorities, etc. for the entire building including all liasoning works, filing necessary applications, submission of forms for approval to the authorities, all required drawings preparation and approval including attending meetings, depositing the fees / other amounts as required for getting the premises / installations, inspected and approved and all other formalities required for getting the approval. All professional charges, liasoning charges & the expenses incurred in this regard shall be borne by the Contractor. Four Sets of paper print of as built drawings& as soft copy of these drawings to be submitted to the clients while completion.

1

-

-

... More
LIGHTNING PROTECTION SYSTEM & STRUCTURAL EARTHING

-

-

-

... More
Supply, installation, Testing and Commissioning of following

-

-

-

... More
External Lightning Protection System -Air Termination System and Inter-Connection Supply and Installation of 8mm dia Aluminium alloy Solid Round Conductor of material AlMgSi used in air termination and down conductor system . Cross sectional area of conductor should be 50 mm². Test Parameter: a.Lightning impulse current of 100kA for 10/350 µs b.Electrical resistivity - 0.034 µΩm, c.Tensile strength - 178 MPa or N/mm² d. Salt spray - No Sign of Corrosion. Tested as per IEC 62561-2.

570

-

-

... More
Supply and Installation of Nylon Conductor Holder for Parapet wall for holding 8 mm dia Aluminium alloy round Conductor.

465

-

-

... More
Supply of Nylon roof conductor holder for flat roof with concrete block for fixing 8 mm dia Aluminium alloy Solid Round Conductor in the terrace flat surface at every 1 mtr.

110

-

-

... More
Supply and Installation of Stainless steel 304 Grade Cross Connector for 8 mm dia Aluminium alloy round conductor & 10 mm Copper bonded conductor at cross/Tee junction. Test Parameter a) Mechanical Load b) Electrical Test c) ENvironmental Test Tested for IEC 62561-1

88

-

-

... More
Supply and Installation of Expansion Joint with connector to compensate the expansion and contraction of Solid Round Al. Conductor during temperature variations. Expansion Joint should be consider at every 20 mtr length of straight horizontal air termination and connected at both the end with use of straight connector conductor.

22

-

-

... More
Supply and Installation of Aluminium Straight conductor connector for interconnecting 8mm Aluminium conductor to meets the requirement of IS/IEC 62305. Test Parametres: a) Mechanical Load b) Electrical Resistivity c) Environmental Test Tested as per IEC 62561-1

15

-

-

... More
Supply and Installation of air termination rod of 4mtr length of material AlMgSi of diametre ø 16/10 mm crimped on both the ends (Tappered Type). The rod shall be mounted with stainless steel clamp and fixing accessories. Test Parameter for 1 mtr vertical air terminal

6

-

-

... More
Supply and Installation of air termination rod of 4mtr length of material AlMgSi of diametre ø 16/10 mm crimped on both the ends (Tappered Type). The rod shall be mounted with stainless steel clamp and fixing accessories. Test Parameter for 1 mtr vertical air terminal

8

-

-

... More
Supply and Installation of Vertical airterminal with corner protecting measure along with suitable mounting arrangements to protect the corners and edges of terrace area and to avoid side flashes. Test Parametres for 500 mm vertical air terminal a) Electrical Resistivity b) Tensile strength c) Condition of bend d)Condition of adhesion e) Copper coating thickness f) Condition of Salt mist Tested as per IEC 62561-2

4

-

-

... More
Supply and Installation of Stainless steel SS 304 Grade Folding Clamp as per sheet profile for 8 mm dia Aluminium alloy Solid Round Conductor for horizontal Air terminal above metal sheet to meet the requirements for IS/IEC 62305. Test Parameter: a) Mechanical Load b) Environmental Test Tested as per IEC 62561-4

10

-

-

... More
Supply and Installation of Earthing stud & suitable Clamp of dimension 69 x 69 mm used in structural steel ring earthing system to meet the requirements of IS/IEC 62305. (for interconnecting Air termination and structral down conductors) Cape Type No. ES 1 ( Article No. 401 510 )

24

-

-

... More
Supply and Installation of connecting point for Earth stud with to meet the requirements of IS/IEC 62305.

54

-

-

... More
Supply and Installation of 8mm dia Aluminium alloy Solid Round Conductor of material AlMgSi used in air termination and down conductor system . Cross sectional area of conductor should be 50 mm². Test Parameter: a.Lightning impulse current of 100kA for 10/350 µs b.Electrical resistivity - 0.034 µΩm, c.Tensile strength - 178 MPa or N/mm² d. Salt spray - No Sign of Corrosion. Tested as per IEC 62561-2.

1300

-

-

... More
Supply and Installation of Nylon Conductor Holder for Parapet wall for holding 8 mm dia Aluminium alloy round Conductor.

1300

-

-

... More
Supply and Installation of Aluminium Straight conductor connector for interconnecting 8mm Aluminium conductor to meets the requirement of IS/IEC 62305. Test Parametres: a) Mechanical Load b) Electrical Resistivity c) Environmental Test Tested as per IEC 62561-1

85

-

-

... More
Supply and Installation of Stainless steel SS 304 Grade Conductor Holder for fixing the 8 -10 mm dia round conductor on the wall . Test Parameter: a) Mechanical Load b) Environmental Test Tested as per IEC 62561-4

20

-

-

... More
Supply & Installation of Lightning counter - LCD screen shows the number of lightning strikes, hour and date of lightning events Buttons enable TIME/DATE setting and log viewing. Replaceable battery, working life minimum five years, Complies with IEC/EN 62561-6.

1

-

-

... More
Supply & Installation of Stainless Steel 304 grade Test Joint with enclosure to interconnect between 8 mm Al. round conductor to 10 mm copper bonded round conductor. Test Parameter: Salt Spray Test for test joint plate -No sign of Corrosion Tested as per IEC 62561-1

20

-

-

... More
Structural Down Conductors - Raiser Supply and Installation of Rust resistant non corossive 10 mm dia Copper Bonded Steel round conductor used for Earth termination inside the concrete and soil. Test parameter:

1520

-

-

... More
Supply and Installation of stainless steel Straight Connector at every 4Mtr of integrated down conductor and should be tested for electrical resistivity, mechanical load to meet the requirement for IS/IEC - 62305 and IEC 62561-1&2.

305

-

-

... More
Supply and Installation of Bonding clamp for interconnecting Round Conductor with reinforcement rebar at every 3Mtr inside the concrete to meet the requirements of IS/IEC 62305.

505

-

-

... More
Supply and Installation of Stainless steel Earthing stud with connector & suitable Clamp used in structural steel ring earthing system to meet the requirements of IS/IEC 62305.

25

-

-

... More
TN-S PME Earthing System Supply and Installation of Diagonal clamp for interconnecting Round Conductor with reinforcement rebar at every 3Mtr inside the concrete to meet the requirements of IS/IEC 62305.

222

-

-

... More
Supply and Installation of Rust resistant non corossive 10 mm dia Copper Bonded Steel round conductor used for Earth termination inside the concrete and soil. Test parameter:

480

-

-

... More
Supply and Installation of 18 mm copper bonded Solid Steel Round Conductor with minimum coating thickness 70µm as integrated down conductor. Material should be tested Tensile strength, Electrical Resistance, salt mist, Bend & Adhesion to meet the requirements of IS/ IEC 62305 and IEC 62561-1&2.

1120

-

-

... More
Supply and Installation of Bonding clamp for interconnecting Round Conductor with reinforcement rebar at every 3Mtr inside the concrete to meet the requirements of IS/IEC 62305.

300

-

-

... More
Supply and Installation of stainless steel Straight Connector at every 4Mtr of integrated down conductor and should be tested for electrical resistivity, mechanical load to meet the requirement for IS/IEC - 62305 and IEC 62561-1&2.

86

-

-

... More
Supply and Installation of 18mm stainless steel Straight Connector of integrated down conductor and should be tested for electrical resistivity, mechanical load to meet the requirement for IS/IEC - 62305 and IEC 62561-1&2.

175

-

-

... More
Supply and Installation of suitable MS cross connector for 10 mm round conductor inside concrete and should be tested for electrical resistivity and mechanical load to meet the requirement of IS/IEC - 62305 and IEC 62561-1&2.

10

-

-

... More
Supply and Installation of suitable MS cross connector for 18 mm round conductor inside concrete and should be tested for electrical resistivity and mechanical load to meet the requirement of IS/IEC - 62305 and IEC 62561-1&2.

105

-

-

... More
Supply and Installation of Cu Earthing stud with fixing clamp accessories used in structural steel ring earthing system to meet the requirements of IS/IEC 62305. Rated Current (CPRI TESTED): Irms- 50 KA per sec; Ipeak- 110 KA per sec

13

-

-

... More
Supply and Installation of Cu Earthing stud with fixing clamp accessories used in structural steel ring earthing system to meet the requirements of IS/IEC 62305. Rated Current (CPRI TESTED): Irms- 28 KA per sec; Ipeak- 79 KA per sec

22

-

-

... More
Supply and Installation of Stainless steel Earthing stud with connector & suitable Clamp used in structural steel ring earthing system to meet the requirements of IS/IEC 62305. Rated Current (CPRI TESTED): Irms- 5 KA per sec; Ipeak- 10.5 KA per sec

61

-

-

... More
Supply and Installation of Earthing stud with fixing clamp accessories used in structural steel ring earthing system to meet the requirements of IS/IEC 62305. Rated Current (CPRI TESTED): Irms- 8 KA; Ipeak- 17 KA Per sec

70

-

-

... More
Foundation Earthing- Mesh Supply and Installation of Rust resistant non corossive 10 mm dia Copper Bonded Steel round conductor used for Earth termination inside the concrete and soil. Test parameter: a) Short circuit current test for copper bonded conductor:Test 6 kA ratings, as per cross sectional area for 1 sec (IS3043/IEEE80); b)Electrical Resistivity before & after salt mist spray test: 0.25µΩm max. c)Tensile Test 290 to 510 N/mm². d)Adhesion no peel or crack & Bend test no seperation of Cu, e)Cu Coating thickness min. 70µm. Tested as per IEC 62561-2.

1300

-

-

... More
Supply and Installation of Diagonal clamp for interconnecting Round Conductor with reinforcement rebar at every 3Mtr inside the concrete to meet the requirements of IS/IEC 62305.

300

-

-

... More
Supply and Installation of stainless steel Straight Connector at every 4Mtr of integrated down conductor and should be tested for electrical resistivity, mechanical load to meet the requirement for IS/IEC - 62305 and IEC 62561-1&2.

42

-

-

... More
Supply and Installation of suitable MS cross connector for 18 mm round conductor inside concrete and should be tested for electrical resistivity and mechanical load to meet the requirement of IS/IEC - 62305 and IEC 62561-1&2.

80

-

-

... More
Supply and installation of Corrosion Bitumen tape for inside soil.

4

-

-

... More
Installation of Exothermic Welding - Including welding mould and other accessories for welding confirms the requirements of IEEE 837:2014 : T-Joint X- Joint, L -Joint, Straight joint.

45

-

-

... More
Supply of UL Listed & CPRI tested maintenance free ,Low carbon copper coated earth rod of 3 metre electrode having diameter of 17.2 mm with copper coating thickness of 250micron tested as per IEC 62561-2 & is provided with universal clamp made of SS to connect rod with flat conductor. Earth conductivity enhancing compound shall be of 25 kg/pit tested as per IEC 62561-7,TCLP tested , . The above arrangements shall be provided with Heavy duty earth champer of 5000kg load bearing capacity to ensure the safety of earthing system. Details shall be as per drawing indicated in the lightning protection system.

2

-

-

... More
EARTHING

-

-

-

... More
Supply & Laying of 75x10mm GI. Flat for grounding connections in supports,trays,surface , using necessary fixing materials,insulators at regular intervals as required. The cost shall include minor civil works.

1460

-

-

... More
Supply & Laying of 65x10mm GI. Flat for grounding connections in supports,trays,surface , using necessary fixing materials,insulators at regular intervals as required. The cost shall include minor civil works.

1320

-

-

... More
Supply & Laying of 50x10mm GI. Flat for grounding connections in supports,trays,surface , using necessary fixing materials,insulators at regular intervals as required. The cost shall include minor civil works.

1260

-

-

... More
Supply & Laying of 40x6mm GI. Flat for grounding connections in supports,trays,surface , using necessary fixing materials,insulators at regular intervals as required. The cost shall include minor civil works.

100

-

-

... More
Supply & Laying of 50x6mm GI. Flat for grounding connections in supports,trays,surface , using necessary fixing materials,insulators at regular intervals as required. The cost shall include minor civil works.

1220

-

-

... More
Supply & Laying of 50x10mm CU. Flat for grounding connections in supports,trays,surface , using necessary fixing materials,insulators at regular intervals as required. The cost shall include minor civil works.

820

-

-

... More
Supply & Laying of 50x6mm CU. Flat for grounding connections in supports,trays,surface , using necessary fixing materials,insulators at regular intervals as required. The cost shall include minor civil works.

400

-

-

... More
Supply & Laying of 25x6mm CU. Flat for grounding connections in supports,trays,surface , using necessary fixing materials,insulators at regular intervals as required. The cost shall include minor civil works.

600

-

-

... More
Supply & Laying of 25x3mm GI. Flat for grounding connections in supports,trays,surface , using necessary fixing materials,insulators at regular intervals as required. The cost shall include minor civil works.

3800

-

-

... More
Supply & Laying of 25x6mm GI. Flat for grounding connections in supports,trays,surface , using necessary fixing materials,insulators at regular intervals as required. The cost shall include minor civil works.

4200

-

-

... More
Supply & Laying of 6 Sq.mm. Cu. Wire for grounding connections in supports,trays,surface , using necessary fixing materials,insulators at regular intervals as required. The cost shall include minor civil works.

760

-

-

... More
Supply & Laying of 4 Sq.mm. Cu. Wire for grounding connections in supports,trays,surface , using necessary fixing materials,insulators at regular intervals as required. The cost shall include minor civil works.

1230

-

-

... More
Supply & Installation of Busbar of 0.5 Mtr length made out of 50x6 mm GI strip with drill holes of M8 at 25mm interval mounted on insulators with Enclosure Box with visible glass

26

-

-

... More
Supply & Installation of Busbar of 0.5 Mtr length made out of 25x6 mm GI strip with drill holes of M8 at 25mm interval mounted on insulators with Enclosure Box with front visible glass

41

-

-

... More
Supply & Installation of Busbar of 0.5 Mtr length made out of 25x6 mm Cu strip with drill holes of M8 at 25mm interval mounted on insulators with Enclosure Box with front visible glass

34

-

-

... More
Earthing Pits

-

-

-

... More
Supply,installation, testing and commissioning of GI Pipe Electrode Earthing System:Pipe Earth Electrode using 38 mm dia class B GI pipe complete as per IS 3043 with salt, charcoal, brick masonary chamber with heavy duty RCC cover of 450mm x 450mm x 300mm chamber. (Earth strip to be left upto the Earthpit for Connection) The rates shall include excavation of the pit, construction of masonry chamber, providing heavy duty concrete cast slab, painting & making etc.,& as per the technical specification. The supporting pipe, funnel sizes, etc as per NBC.

10

-

-

... More
Supply,installation, testing and commissioning of Copper plate Electrode Earthing System:Plate Earth Electrode using 19 mm dia  Class B  copper plate of size 600 x 600 x 3 mm thick.with heavy duty RCC cover of 450mm x 450mm x 300mm chamber.(Earth strip to be left upto the Earthpit for Connection) The rates shall include excavation of the pit, construction of masonry chamber, providing heavy duty concrete cast slab, painting & making etc.,& as per the technical specification. The supporting pipe, funnel sizes, etc as per NBC.

15

-

-

... More
Supply and insallation maintenance free Earthing System comprising of carbon coated (with micron bonding of 100 Microns) 3 Mtrs long earth MS electrode with pipe in pipe technology of 76mm outer dia Dia and 42mm inner dia overall and 25 kgs. of environment friendly backfill compound with suitable clamp and all other required accesroes for its complete commiosing of Earth pit with effective resistance as per Specifications,

30

-

-

... More
Electrostatic Earthing system for tanker grounding. Supply and installation of earthing integrity monitoring system for tanker unloading with all necessary indications , interlockings , alarms , switches and cable entry points. The System shall be in flame proof enclosure with CCOE certification.

2

-

-

... More
UPS & BATTERY

-

-

-

... More
Supply, installation, testing and commissioning of Modular type scalable UPS system with 90 Mins Battery Back up for consisting of 50KVA UPS with online Hot swappable (Safe operation) IGBT UPS modules in capacity of capacity of 10 KVA to 30 KVA each with necessary BMS compatibility (hardware & software items for third party integration) with MODBUS protocol RS485, Telenet service -communication with LAN for sending mails/ messages in case any tripping or maintenance required with necessary software.

1

-

-

... More
Supply, installation, testing and commissioning of Battery banks of requisite quantity and AH rating suitable for 50 kVA (Continuous rating) online, modular UPS system with one suitably rated DC circuit breaker on each string with all necessary interconnecting links/wiring for each of above UPS units with 90 minutes back up at rated load. Battery shall be of the sealed maintenance free Valve Regulated Lead Acid (VRLA) stationary type 12V blocks conforming to technical specification.

1

-

-

... More
Supply, installation, testing and commissioning of Modular type scalable UPS system with 30 Mins Battery Back up for consisting of 100KVA UPS with online Hot swappable (Safe operation) IGBT UPS modules in capacity of capacity of 10 KVA to 30 KVA each with necessary BMS compatibility (hardware & software items for third party integration) with MODBUS protocol RS485, Telenet service -communication with LAN for sending mails/ messages in case any tripping or maintenance required with necessary software.

1

-

-

... More
Supply, installation, testing and commissioning of Battery banks of requisite quantity and AH rating suitable for 100 kVA (Continuous rating) online, modular UPS system with one suitably rated DC circuit breaker on each string with all necessary interconnecting links/wiring for each of above UPS units with 30 minutes back up at rated load. Battery shall be of the sealed maintenance free Valve Regulated Lead Acid (VRLA) stationary type 12V blocks conforming to technical specification.

1

-

-

... More
EV Charging Equipments

-

-

-

... More
Supply, Installation, Testing and Commissioning 7.2 kW AC Electric Vehicle charger (suitable for 4 wheeler) having minimum IK08 & IP55 protection suitable for single phase, 230V AC, 50Hz, incoming and 1 nos. output having capacity of output current of 32A at 230V with Type two connector as per IEC 62196-2 , Interlocking arrangement & minimum 5 meter charging cable length, 3.5" TFT screen for human interface & LED light for status indication and metering for measurement of consumed energy having metering accuracy +/- 1%, one hour battery backup for server communication, emergency push stop button, with user interface by mobile application/QR Code/RIFD Card/Password Login and having short circuit, over & under voltage, overload, earth leakage ,Over temperature, surge protection and enclosure made of minimum 1.5mm duly RAL7035 coated M.S, erected on iron/GI frame on provided cement concrete foundation complete with one year on site warranty,confirming to IS 17017 Series as per specification

10

-

-

... More
Supplying, erecting, testing and commissioning of 10kW, 3 x 3.3 KW AC Electric Vehicle charger (suitable for 2/3/4 wheeler) having minimum IK08/IP 55 Protection suitable for three phase, 415V AC, 50Hz incoming and 3 nos. output as per IEC 60309 industrial sockets having capacity of output current of 16A 240V AC at each socket with 3.5"TFT touch screen for human interface & LED Light for status indication and metering for measurement of consumed energy having metering accuracy +/-1%, one hour battery backup for communication, emergency push stop button and having short circuit, over & under voltage, overload, over temperature, earth leakage protection and enclosure made of minimum 1.5mm duly RAL7035 Coated M.S, Erected on iron/GI frame on provided cement concrete foundation complete with one year on site warranty, confirming to IS 17017 Series as per specification.

18

-

-

... More
Roof Top Solar PV Systems

-

-

-

... More
Design, supply, installation, testing and commissioning of Solar PV roof top system. The cost shall includes Solar PV Mono Perc Crystalline type panels, lightning protection system, solar inverters with harmonic filters, inverter duty transformers, combiner box, junction box, DC/AC cable, power cable, control cable & communication cable, Module Mounting Structure for Front and Back post type alongwith HDGI type ,SS fasteners, uPVC Conduit pipes, Cable Tray , MC4 Connectors (pair set) and others like DC+AC Consumables ( Earthing Cables, Cable tie, markers, MC4 Crimping tool, Ferrules etc), Anti corrosion material should be used. Required DC DB, connecting to Utility Panel, Birectional generation meter, earting till main earthing grid, Cable termination, cabling upto mainutilty panel,any other accessories required for successful commissioning of solar PV system. BMS interface shall be provided for inverter.This works including approvals from required statuatory departments .

70

-

-

... More
Elevator Systems

-

-

-

... More
Passenger Elevator 1. Design, Supply, installation, testing and commissioning of the following lifts as per technical specifications/drawings and PMC/Employer in charge 2. Procurement of items with aesthetic value and visibility Ii.e, final finishing selection shall be as per instructions / on prior approval from PMC/Employer in charge for specific area of application. Passenger lifts (1360kg) - (Machine room with Regenerative Drive) having contract speed of 1.75mps serving different floor in the lift shaft as per detailed specifications enclosed and as under: (i) Load: 1360kg (ii) Capacity: 20 passengers (iii) Speed: 1.75mps (iv) Floor Marking: 13 (GR to 12th Floor) (v) Travel: As per Arch. Drgs (58mtr) (vi) Stops & opening: 13 stops/13 opens (vii) Controller: ACVVVF-Regenerative Drives (viii) Automatic rescue device complete as required (ix) Operation: 5 Car group passenger lifts with DCS. FULL DOAS system with 2 key pads in GF and 2 key pads in all other floors with voice announcement and braille with disabled friendly feature. (x) Hoistway available: 2500mm W x 2400mm D (xi) Car size : “Max. Car sizes shall be as per NBC 2016” (xii) Type of doors (a) Car Doors: SS Textured Panel (Scratch Proof) (b) Landing doors: SS Brushed Finish .1300mm W x 2300mm H Center Opening .

10

-

-

... More
(xiii) Lift Car Finishes: Side & Rear walls - SS Textured Panel (Scratch Proof) Ceiling - SS Brushed Finished Panel with protected LED light of indirect lighting with min.150 Lux at 1 meter above floor level. Rectangular grill in ceiling with Exhaust blower fans covering full length width with overhead ventilation grids for optimum air flow. Noise level of ventilation fan shall be limited with 35dB(A) at 1m distance Flooring - 25mm recess in platform with Granite finish (As per approval from PMC/Employer in charge) Kick plate shall be as per Panel Finsih with 2-3 inch height. Lift shaft reducing channels to be considered if required. All Finishes shall be to resistant fingerprint marks from constant use for ease cleaning and maintenance. Final finishing selection shall be as per instructions of PMC/Employer in charge Other parameters / requirements should be considered as per detailed specification sheet. All elevators shall be provided with regenerative drives. The regenerative power developed shall be utilised in the elevator system itself. % of energy saving shall be as per OEM design. Bidder to demonstrate the energy saving due to usage of regenerative drives during the commissioning of elevator. Hand rail not less than 600mm long at 900mm above floor level to be fixed adjacent to control panel in lift car. Voice announcement system in the car to announce the position of the lift in the hoistway as the car passes or stops at a floor served by the lift.

-

-

-

... More
Service Lift 1. Design, Supply, installation, testing and commissioning of the following lifts as per technical specifications/drawings and as directed by Engineer In Charge. 2. Procurement of items with aesthetic value and visibility Ii.e, final finishing selection shall be as per instructions / on prior approval from PMC/Employer in charge for specific area of application. Service lifts with 1360kg - (Machine room with Regenerative Drive) having contract speed of 1.5mps serving different floor in the lift shaft as per detailed specifications enclosed and as under: (i) Load: 1360kg (ii) Capacity: 1360kg (iii) Speed: 1.5mps (iv) Floor Marking: 14 (B2 to Terrace) (v) Travel: As per Arch. Drgs (64mtr) (vi) Stops & opening: 14 stops/14 opens (vii) Controller: ACVVVF-Regenerative Drives (viii) Automatic rescue device complete as required (ix) Operation: Simplex (x) Hoistway available: 2500mm W x 2750mm D (xi) Car size : “Max. Car sizes shall be as per NBC 2016” (xii) Type of doors (a) Car Doors: SS Textured Panel (Scratch Proof) (b) Landing doors: SS Brushed Finish .1300mm W x 2300mm H Center Opening .

2

-

-

... More
(xiii) Lift Car Finishes: Side & Rear walls - SS Textured Panel (Scratch Proof) Ceiling - SS Brushed Finished Panel with protected LED light of indirect lighting with min.150 Lux at 1 meter above floor level. Rectangular grill in ceiling with Exhaust blower fans covering full length width with overhead ventilation grids for optimum air flow. Noise level of ventilation fan shall be limited with 35dB(A) at 1m distance Flooring - 25mm recess in platform with Granite finish (As per approval from PMC/Employer in charge) Kick plate shall be as per Panel Finsih with 2-3 inch height. Lift shaft reducing channels to be considered if required. All Finishes shall be to resistant fingerprint marks from constant use for ease cleaning and maintenance. Final finishing selection shall be as per instructions of PMC/Employer in charge. Other parameters / requirements should be considered as per detailed specification sheet. All elevators shall be provided with regenerative drives. The regenerative power developed shall be utilised in the elevator system itself. % of energy saving shall be as per OEM design. Bidder to demonstrate the energy saving due to usage of regenerative drives during the commissioning of elevator. Hand rail not less than 600mm long at 900mm above floor level to be fixed adjacent to control panel in lift car. Voice announcement system in the car to announce the position of the lift in the hoistway as the car passes or stops at a floor served by the lift.

-

-

-

... More
DIESEL GENERATING SETS (WITH ACCOUSTIC ENCLOSURE)

-

-

-

... More
Supply, design, Manufacturing, testing at manufacturers works & delivery to site including packing, transportation to site, installation, testing at site and commissioning of 3 Phase 415 Volts 50 cycle per second, 1500 RPM ,2250KVA Prime Rated Radiator Fan Cooled Diesel Generator Sets with PCC 3.3 and accoustic enclosure. The engine shall be complete with turbo charger, flywheel to suit flexible coupling with guard, air cleaner, blower fan, fuel pump, variable speed electronic governor, fuel filter, lube oil filter and pump, primary water circulating pumps, battery charger, 24 volt batteries of compatible capacity, MS battery stand and instrument panel comprising of switch with key, lube oil pressure gauge, water temperature gauge, battery charging voltmeter, safety control for low lube oil pressure, over speed and high cooling water temperature with tripping. The alternator shall be self excited, self regulated, brushless and continuously rated for kVA at 0.8 P.F., 3 phase 415 volts, 50 cycle per second, 4 wire system and shall be provided with static excitation unit. Alternator insulation shall be class 'H' suitable to withstand tropical conditions and shall generally comply with latest up to date amendment to IS Code. The overload capacity shall not be less than 110% of rated capacity for 1 hour in every 12 hours. The DG Set shall be mounted on a fabricated rigid common base frame with anti-vibration mountings to provide 98% vibration isolation. The DG set shall include all accessories, fittings, instruments and standard tool kit complete as per specification and as required including control cabling. The cost shall include providing and fixing adaptor box for cable termination as required. The Governing system of the Diesel genets shall be compatible with the Synchronizing and auto load sharing The cost shall include providing adopter box for 415 alternator with rubber bellows.All DGs shall have the quick start facility. First Fill lube oil alsoshal be part of supplier scope only.

3

-

-

... More
ACB enclosures: Supply Installation testing and commisioning of DG isolator Panel As per SLD shall be mounted on the alternator with necessary supports, anti-vibration connections, mounting brackets, MS stand, clamps etc. and suitable size of flexible copper bus bars / univyn cables between DG alternator terminal to the box along with 4000A 4 Pole ACB. 4000A 55kA 4P EDO ACB Panel with provision of suitable size bus bars for Incomming cable of suitable runs to suffice the load requirements and outgoing Bus Duct connections with O/C, S/C, E/F release SC for 1 sec as Isoaltor Unit made with 2mm thick steel sheet enclosure (IP55) duly powder coated with ACB complete with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system, with all fixing accessories etc. as required.

3

-

-

... More
Design, Supply Installation testing and commisioning of of Adaptor box suitable for 2250kVA DG set connecting alternator terminals to Isolator incomer by copper flexibles / univyn cables. The adopter box shall have adequate space for mounting CT's for REF & Differential protection relays and Neytral contractor & as per SLD. The adaptor box shall be mounted on the alternator with necessary supports, anti-vibration connections, mounting brackets, MS stand, clamps etc. to mount the adaptor box shall be included in the price. No extra claim is entertained. Price shall be inclusive of suitable size of flexible copper bus bars / univyn cables between DG alternator terminal to the adapter box. Please refer to single line diagram and technical specification for more details. Note : CT's for REF & Differential protection will be loose supply from the DG Vendor Panel manufacturer and installation at DG side shall be carried out by DG vendor.

3

-

-

... More
Supply Installation testing and commisioning of Retrofit Emission control device suitable for 2250 KVA, 415 Volts prime rating diesel generating set, as per the commission for air quality management and their recent directions, RECD should match the emission control criteria, Smoke shall not exceed prescribe value throughout the operating load points of the test cycle, as per the latest directions by CAQM/State pollution control board/CPCB & NGT suitable for 2250 KVA, 415 volts DG set. RECD shall have no effect on exhaust back pressure. The back pressure shall be maintained within prescribed limit by the manufacturer. There should not be any backflow from RECD to engine exhaust system. Type Approval of RECD for family of DG Sets should be as per CPCB instructions and the same has to be obtained from the CPCB prescribed labs . Any other equipments required with RECD to comply the CAQM criteria required to be consider in this Item only.The RECD shall be certified by one of the approved & recognised agencies by the central air pollution control board. RECD should have IoT based controller to remotly measure the parameters by the pollution control board website directly as and when required, also should have communication port for BMS through backnet over IP with open protocol connectivity. Retrofit Emission Control device (RECD) in suitable weather proof canopy with suitable provision for termination of IN and OUT of exhaust pipes ( including the manifolds if required for connection) to meet the local standards etc. The system shall be complete with all accessories including cabling, termination, outdoor MCC panel including necessary power cabling , earthing etc. as per the technical specification (IF THIS ITEM IS NOT REQUIRED BY THE VENDOR & THEY ARE FULFILLING THE LATEST CAQM CRITERIA OF EMMISSION CONTROL, THEN CONFRIMATION FROM OEM SHALL BE SUBMITTED)

3

-

-

... More
CONTROL CABLES

-

-

-

... More
Supply , laying of 1.1KV Grade FRLS Copper armoured Control Cabling inbetween Day oil tanks, DG Sync Panel/DG power Panel, Auxillary power panel, Sensing cables from utility power panels along with its end terminations inclusive of brass double compression glands and copper lugs for complete auto & manual control and logical operations. All necessay control cabling shall be considered under this line Item required for fully auto operation of entire DG & Fuel system.

-

-

-

... More
Supply & end termination of following CU FRLS armoured power/ control (shielded Signal) cables with necessary double compression brass glands, CU. terminal sockets, insulation tapes, fasteners, earthing clips & connecting the clip to main earth bus with suitable bare copper wire complete accessories as required

-

-

-

... More
24C x 1 sq. mm. YWY cable

100

-

-

... More
End termination for 24C x 1 sq. mm. YWY cable

20

-

-

... More
12C x 2.5 sq. mm. YWY cable

300

-

-

... More
End termination for 12C x 2.5 sq. mm. YWY cable

15

-

-

... More
10C x 2.5 sq. mm. YWY cable

300

-

-

... More
End termination for 10C x 2.5 sq. mm. YWY cable

15

-

-

... More
6C x 2.5 sq. mm. YWY cable

300

-

-

... More
End termination for 6C x 2.5 sq. mm. YWY cable

15

-

-

... More
4C x 2.5 sq. mm. Cu. Flexible cable (Shielded )

300

-

-

... More
End termination for 4C x 2.5 sq. mm. Cu. Flexible cable

15

-

-

... More
4C x 2.5 sq. mm. YWY cable

10

-

-

... More
End termination for 4C x 2.5 sq. mm. YWY cable

2

-

-

... More
3C x 2.5 sq. mm. YWY cable

200

-

-

... More
End termination for 3C x 2.5 sq. mm. YWY cable

15

-

-

... More
2C x 4 sq. mm. YWY Cable

10

-

-

... More
End termination for 2C x 4 sq. mm. YWY Cable

2

-

-

... More
2C X 2.5 Sq. mm YWY cable

200

-

-

... More
End termination for 2C X 2.5 Sq. mm YWY cable

15

-

-

... More
4 Core x 1.5Sq.mm, PVC Insulated Copper conductor armoured cable for control cabling

300

-

-

... More
End Terminations 4 Core x 1.5Sq.mm, PVC Insulated Copper

4

-

-

... More
4 Core x 2.5Sq.mm, PVC Insulated Copper conductor armoured cable for sensor

60

-

-

... More
End Terminations 4 Core x 2.5Sq.mm, PVC Insulated Coppe

4

-

-

... More
FUEL SYSTEM :

-

-

-

... More
Charges towards First fill of High Speed Diesel as per requirements of Day Oil of 3 Nos. Individual 415V , 2250 KVA LT DG Sets.

1

-

-

... More
Supply Install , testing and commisioning of 990 Ltrs tank . The fuel tank shall be fabricated from 2 mm thick MS sheets and shall include the cost of removable cover with locking arrangement, the cost of painting, the cost of providing all the required appurtenances like inlet & outlet connection, float valves, drain connection, oil level indicator and low level/high level alarms and the cost of support arrangement And all other necessary accesories required for its complete installation complete as per specification as required. Level indicator shall be compatibel to BMS integration. The 990 Ltrs Tank shall be used as Day Oil Tank for individual DG Sets , Over flow tank and Buffer tank. M.S Steel Structure required for complete errection and installation shall be considered in this line item.

5

-

-

... More
EXHAUST SYSTEM 'Supply, Erection, Testing & Commissioning of Self-supporting M.S Class B or 5mm thick DG Exhaust Pipes as specified & complete with all M.S supporting structures, sampling point, two coats of red oxide and anti corrosive painting, necessary anti-vibration supports, floor brackets, required insulation of 100mm thickness having density of 64 Kg/ M3 wrapped in chicken mesh and cladding as with 24 gauge alluminium sheet specified including erection. Expansion bellows shall be provided at necessary location. The diameter of the exhaust pipe has to be decided by DG vendors considering the horizontal and vertical length, bends involved to take required height for discharge as per CPCB norms.Back pressure calculation has to be submitted by DG vendor and get approved from Engineers incharge.

-

-

-

... More
Exhaust pipe

-

-

-

... More
300mm dia. Exhaust Pipe

70

-

-

... More
600mm dia. Exhaust Pipe

320

-

-

... More
Supply & Installation of Exhaust hot air GI duct with louvers with angle frame work & fixing accessories, to be fixed on external wall to throw hot air from chamber, it shall be suitable for supplying required air in CFM for Above DGs. complete system has be considered with rain water protection fins wherever required.

120

-

-

... More
Silencer

-

-

-

... More
Supply, Installation , Testing and commisioing of Silencer Insulation 50mm thick lightly resin bonded (LRB) rock wool (64 Kg/m3 density) insulation clad with 26 SWG aluminium sheet cladding.

6

-

-

... More
Supply and installation of stainless stell vent cowl suitable for exhaust piping as provided above will all the necessary fixing arrangments and accessories to make it fully functional.

3

-

-

... More
Supply and installation of SS flexible bellows

-

-

-

... More
SS flexible bellows-300 mm dia

6

-

-

... More
SS flexible bellows-600 mm dia

3

-

-

... More
DG SYNCHRONIZING PANEL

1

-

-

... More
Supply, erection, testing and commissioning of 415V, 3 phase 4 wire 50 Hz, fully compartmentalized cubical type, fabricated with CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having required capacity extensible type FP Copper alloy bus bars of high conductivity, DMC / SMC bus bars of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity as mentioned in the below & SLD, bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, Form of separation shall be form 4B with metallic separation only entire panel shall have a common copper earth bar size as per OEM requirements at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Cu. bus bars, interconnection, interlocking between feeders etc., Annuntiation window requirement shall be as per SLD. with indication lamps, push buttons necessary accessories, complete with following incoming and outgoing switchgears with protection and metering etc. as per specification and schematic diagram including provision to be made for interfacing with BMS etc. complete as required with incoming & outgoing cable entry from bottom/top and bus-duct entry from top, wiring with 2.5sq. mm. PVC insulated FRLS copper conductor , cable alleys, cable gland i/c providing following switch gears All ACBs should have Ics=Icu=Icw for 1 sec All MCCBs shall be rating for Ics=Icu as per provided SLD. All MCCBs above 63A should be provided with Copper Spreader Terminals Marshalling Bay To Be Provided for BMS Operation Please consider IP42 for Indoor panel & IP 55 for out door panels if it is not specified . Approval shall be taken for each panel before fabrication. contractor to consider the termination requirement as per the cable sizes sheet provided.

-

-

-

... More
If any additional termination box is required the same shall be considered by contractor in the panel cost itself. The fault level of the component shall be same as the bus bar fault level indicated. The panel shall be designed to suit to the site condition. If any U shape/L shape panels required as per site requirement, contractor to consider all required dummy panel, adaptor boxes, bus bar extension, other accessories, etc. in the panel cost itself. All the cost required for BMS integration like cable,control modules,converters, connectors etc as per the attached scheme shall be included in panel cost itself. The scope shall include relay coordination study. ON / OFF / TRIP status for all the incomming breakers (ACB, MCCB, MCB, MPCB, RCBO) & meter parameter from all main panel (Listed Below) to be provided through modbus IP output (PLC) to connect to BMS through ethernet switch located within one of the panels in each electrical room. All cost towards cable, ethernet switch, BMS interface module, etc shall be covered in the panel cost itself. This Panelshall be OEM Certified ( IEC 61439) type tested approved design. Surge Protection device of sutibale type and range to be considered as per the SLD. Any details indicated in SLD and specification is also need to be consiedered for panel cost. Any details indicated in SLD and specification is also needs to be consiedered for panel cost. Internal ARC shall be provided. Type Test certificates shall be submitted for all the componenents. Note : Refer the SLD - TCE.13417A-EL-4002-AU-40011 to TCE.13417A-EL-4002-AU-40013 .

-

-

-

... More
Incomer 4000A 4P EDO ACB with microprocessor based O/L, S/C and E/F - 3 Nos. Suitable for Bus Duct termination 55kA ALL ACB For indication lamps please refer to SLD Analog Ameter and voltmeter with selector switch - 3 set. SPD type II, 50KA, FP - 3 nos. Multi Function Meter with RS 485 port.- 3 nos. C.T. 4000/1A, CLASS 0.5 10VA-3 set. C.T. 4000/1A, CLASS PS- 3 set. Line PT : 415V/v3/110V/v3, Cl.1, 50VA - 3 set Bus PT : 415V/v3/110V/v3, Cl.1, 50VA - 3 set Bus Coupler : 5000A FP EDO 55kA ACB with microprocessor based O/L, S/C and E/F - 1 Nos. Busbar : 6000A 4P Cubusbar 1sec (55kA) Outgoing : 55kA ALL ACB 4000A 4P EDO ACB microprocessor based with O/L, S/C & E/F Protection - 4 nos. C.T. 4000/1A, CLASS 0.5 10VA- 4 sets Multi Function Meter with RS 485 port.- 4 nos. For indication lamps ,numeric relays, please refer to SLD All incoming and Outgoing breaker should be communicable for status monitoring.

-

-

-

... More
All required relay and synchronization controller shall be provided in the synchronization & control panel. Control & Operation of DG breaker panel shall be only from synchronization & Control panel.Please refer to single line diagram and technical specification for more details Supply, Installation, testing & commissioning of Inert type Novec-1230/FM200 Fire Detection Tube based Gas suppression system for electrical panel. It includes all the require accessories/equipments to complete the panel protection, as per detail specification.

-

-

-

... More
HSD WORKS

-

-

-

... More
Design, Supply, fabrication, testing & commissioning of 20KL capacity MS tank for storing HSD as per drawing for below ground installation. Tank to be suitably fabricated with stiffeners as per approved drawing & IS10987.Tank shall be suitably fabricated with MS plate duly treated with necessary anticorrosive tar plastic compound externally with necessary accessories such as inlet, outlet, manhole, dipstick, fixed holding supports, bolts, nuts and necessary brackets on the tank etc., complete. Rate shall also include for necessary transportation, loading and unloading at site as directed. (Tank should be coated twice with anti-corrosive bituminous paint). Shell Plate 6mm & End Plate 10mm thick, The Dimesensions of 20KL Tank should be considered as per relveant IS standards ( IS 10987 )and as per stauatory requirements. Necessary drawing to be submitted for review and approval from Project Officer before procurement .

2

-

-

... More
HSD Transfer Pump Suppply & Installation, testing & commissioning of HSD Transfer Pump(1W + 1S) with following specification: 1) Type of pump :Centrifugal Pump 2) Capacity : As per Requirement 3) Head to be selected to suit as per site conditions. Pump set to work on 3 phase 415V 50 hz with necessary flame proof motor, suction & delivery outlets, companion flanges, nuts, bolts gaskets, etc . Rate quoted shall also include for base frame and foundation bolts, MS supports as necessary for pump installation also inclusive of rainhood made of GI sheet metal with necessary provision for placing and removing the cover whenever required complete as per data sheets & specification. Inclusive of Suitable size strainers , inlet & outlet side valves and necessary piping for bypass arrangements.

1

-

-

... More
HSD Over flow Pump Suppply & Installation, testing & commissioning of HSD overflow Pump(1W +1S) with following specification: 1) Type of pump :Centrifugal Pump 2) Capacity : As per Data sheet. 3) Head to be selected to suit as per site conditions. Pump set to work on 3 phase 415V 50 cycles with necessary flame proof motor, suction & delivery outlets, companion flanges, nuts, bolts gaskets, etc . Rate quoted shall also include for base frame and foundation bolts, MS supports as necessary for pump installation also inclusive of rainhood made of GI sheet metal with necessary provision for placing and removing the cover whenever required complete as per data sheets & specification.

1

-

-

... More
Suppply & Installation of SS 304 Single Braded wired Flexible hose(Unloading hose) suitable for diesel oil including fittings of one end flanged and other end with suitable coupler. Hose to have ACME End Connectors as per standards for un-loading of fuel. The flexible hose shall be 3 Mtrs in Length and 80 NB Diameter.

2

-

-

... More
Supply & installation of Fuel Transfer Panel -1(FTP-1 IP 43 ) with all required controllers / PLC for communication with pumps and providing power supply to the transfer & overflow pump to be installed inside DG room.

1

-

-

... More
Supply & installation of Fuel Transfer Panel -2 (FTP-2 IP 65 ) with all required controllers / PLC for communication with pumps/ centrifuge unit and providing power supply to the transfer & centrifuge unit to be installed near HSD storage area.

1

-

-

... More
Supply & installation of Explosion Proof Local Push Button station with ON & OFF indication Lamps to be installed near the pumps in HSD Area as per the approved drawings.(IP 65)

2

-

-

... More
Supply & installation of Local Push Button station with ON & OFF indication Lamps to be installed near the pumps as per the approved drawings. (IP - 43)

2

-

-

... More
PIPING FOR FUEL SUPPLY SYSTEM

-

-

-

... More
Suppply & Installation of folowing HSD piping (Heavy Duty Class- 'C') MS ASTM 106 grade B schedule 40 seamless pipe with all accessories/ fittings such as bends,tees unions etc, including necessary G.I. supprts, cutting, welding, Painting with one coat of primer and two coats of enamel paint of approved make. The quoted rate to include all necessary hardware, electrostatic jumpers for all flange joints, Cost of all necessary flanges/matching flanges,Reducers for suction & delivery lines to be included i) G.I. Supports, brackets for piping with all joints, supports etc. ii) installation of pipes in hume pipe laid for road crossing , trenches in DG Room , External trench with all necessary accesories for its complete installation as per IS standrads.

-

-

-

... More
Suppply & Installation of Piping buried in ground / in trenches/ on Floor.

-

-

-

... More
80mm dia.

400

-

-

... More
65mm dia.

10

-

-

... More
50mm dia

140

-

-

... More
40mm dia.

60

-

-

... More
25mm dia.

40

-

-

... More
15mm dia.

10

-

-

... More
Suppply & Installation of Ball Valve

-

-

-

... More
80mm dia.

15

-

-

... More
65mm dia.

2

-

-

... More
50mm dia

15

-

-

... More
40mm dia.

12

-

-

... More
25mm dia.

1

-

-

... More
15mm dia.

3

-

-

... More
Suppply & Installation of Non Return Valve.

-

-

-

... More
80mm dia

2

-

-

... More
65mm dia

1

-

-

... More
50mm dia

4

-

-

... More
40mm dia

1

-

-

... More
25mm dia

1

-

-

... More
Suppply & Installation of Y' STRAINERS

-

-

-

... More
80mm dia.

1

-

-

... More
65mm dia

1

-

-

... More
50mm dia

4

-

-

... More
40mm dia.

1

-

-

... More
25mm dia.

1

-

-

... More
Suppply & Installation of Soleniod valve (Electrically Operated)

-

-

-

... More
80mm dia.

1

-

-

... More
50mm dia.

1

-

-

... More
40mm dia.

3

-

-

... More
25mm dia.

1

-

-

... More
Suppply & Installation of Basket Strainer

-

-

-

... More
80mm dia.

1

-

-

... More
65mm dia.

1

-

-

... More
50mm dia.

1

-

-

... More
40mm dia.

1

-

-

... More
25mm dia.

1

-

-

... More
Pressure Guage / Pressure Indicator. Supply and fixing of Glycerin filled Pressure gauge 6" dial with 20NB isolation valve

4

-

-

... More
Supply, Installation, Testing and commissioning of ultrasonic flow meter complete with all accessories and attachments

-

-

-

... More
80mm dia.

2

-

-

... More
65mm dia.

1

-

-

... More
50mm dia.

1

-

-

... More
40mm dia.

3

-

-

... More
25mm dia.

1

-

-

... More
Level Indicators & level controllers.

-

-

-

... More
Supply and fixing of Digital level indicator for diesel UG tank,day tanks, Buffer tanks & Overflow tank.

7

-

-

... More
Supply and fixing of Level control instrument , for diesel UG tank , day tanks , Buffer tank & Overflow tank with ModBus RS485 connectivity to integrate with BMS System to share the Pump Status and Oil Tank Variable ouputs in terms of Linearity/volume/Percentage of Tank Liquids

7

-

-

... More
Supply and fixing of Drip tray for fuel pipes. The cost shall include necessary supports, necessary clamping on each fuel pipe running in the drip tray.200 x 75mm dia floor mounted MS drip tray, running along the length of fuel storage room and as header for pipes to individual DG's. 100 x 75mm dia floor mounted MS drip tray, running from main header to individual DG's in DG room.

30

-

-

... More
Centrifuge Seperator Machine Supply , Installation , Testing and Commisioing of Centrifuge seperator (1W + 1S) as per specifications & Data Sheet complete with , 1. Exposion proof outdoor type Control Panel with Switchgear and Internal Cabling and Accessories. 2. Explosion proof Motor with necessary switch gear and internal cabling 3. Vavles , Pressure switch , pressure guage. 4. Temperature sensor , preheater ,thermometer. 5. Flow Switch , strainer , oil feed Pump. 6. Control Unit for heater , starters. 7. All Communicating accesories with PLC / Control of respective Fuel Transfer Panel. 7. All Interconnecting Accesories.

1

-

-

... More
LIAISON WORKS Vendor should coordinate and Obtaining clearance, license and safety certificates from State pollution control board, CEIG ,CCOE (if Applicable) and other local bodies, etc if any applicable for installation and operation of the 3x 2250 kVA DG SET.

1

-

-

... More
Charges for liaison work to getting approval from chief controller of Explosive (CCOE) For installation and operation of the storage and transfer system

1

-

-

... More
MISCELLANEOUS ITEMS

-

-

-

... More
Supply and installation of 2m x 1m Rubber Mat suitable for 33 KV & 1000V installation confirming to IS

77

-

-

... More
Supply and installation of framed first aid chart (English & Local language) in panel room

23

-

-

... More
Supply and installation of First Aid Box complete with all First Aid Medicines

23

-

-

... More
Supply and installation of Shock Treatment Chart fixed in glass frame

18

-

-

... More
Supply of Hand Gloves 33KV Grade

5

-

-

... More
Supply & installation of 33 KV Danger boards

7

-

-

... More
Supply & installation of 440V Danger boards

23

-

-

... More
Supply and installation of framed, Laminated SLD in Electrical rooms

16

-

-

... More
Supply & Installation of HT / LT cable route marker complete as per Latest Standards & regulations

11

-

-

... More
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE Energy efficient 1200mm Sweep Ceiling Fan 5 Star Rated, inverter driven controlled by microprocessor with 300mm down rod with regulator / remote control (35 W)

15

-

-

... More
Supply, Installation, Testing and Commissioning of 300mm dia. Box type single phase heavy duty exhaust fan with suitable louvers

10

-

-

... More
Supply, fabrication and installation of MS structural supports including welding, bolting, riveting, supply of necessary anchor bolts and grouting etc, supply of paint and applying one coat of anti rust primer and two finished coats of approved synthetic enamel paint including breaking walls, floors etc. for structures as required including supply of all GI hardware materials, including all labour and materials as per approved drawings, specifications of this tender and directions of PMC / Employer. DG stack`s MS steel structure & painting with two coats of primer zinc oxide and two coats of approved enamel paint. All MS supports shall be measured in this line item (DG Stack, & DG day tank Supports)Quoted price shall be inclusive of Supporting arrangement at all levels & for the metal deck slab shall be with Wedge/ Gripple / Lindapter / fischer fixing arrangement for TR 60 / TR 80 metal decks. (Vendor has to submit Structural design calculation for DG stack supports separately and same shall be reviewed and confirmed by PMC / Employer before execution.

23

-

-

... More
HVAC WORKS

-

-

-

... More
Design, Engineering, Supply, Inspection, testing, erection and commissioning of following items including water and air balancing.

-

-

-

... More
CHILLERS

-

-

-

... More
Design, Supply, delivery, hoisting, including the customs clearance, freight up to site, Insurance, port handling charges, other local duties, loading, transportation, receving at site, unloading, positioning the chiller as per approved shop drawing, installation including supplying & installing all necessary accessories as required for complete and satisfactory operation, testing & commissioning for the following items as shown on the equipment data and drawing for complete and satisfactory operation. Specification to be complied by the vendor to met the performance of chiller as per tender conditions. First chiller shall be factory tested at design conditions at 100%, 75%, 50% and 25% load. (Charges for arranging inspection of chillers for 5 persons, at Manufacturer’s point for witnessing testing the chiller ( 1no. chiller ) at minimum 4 test points. Clearly indicate the facilities available at manufacturer’s point for testing and also confirm wehther test bed is AHRI approved) All necessary hardwares / software's to integrate the chiller panel to BAS system shall be provided free of cost by chiller manufacturer / supplier. Control panel should be with open protocol like Modbus RTU/ Bacnet/ Lon work for integrating with BAS. Chiller is accepted only based on 100% loading and its performance shall be tested at site against approved data sheet. Any fall back on the performance to be corrected and rechecked and then chiller will be accepted.

-

-

-

... More
WATER COOLED CHILLERS -Supply, Installations, testing, erection and commissioning of WATER COOLED CENTRIFUGAL CHILLERS with BMS compatible VFD (Unit mounted factory calibrated. VFD shall be with active harmonic filter with THD not exceeding 5%.VFD shall be liquid cooled only, water/refrigerant cooled as per OEM standard.), IE4 motor, water cooled condenser, insulated chiller, flow switch at chiller and condenser, spring vibration isolators, integral refrigerant piping and wiring, grooved couplings at chilled & condenser water inlets & outlets, marine water box at condenser with hinges, accessories as required and called for, automatic and safety controls mounted in central console panel and all mounted on a steel frame etc. Motor shall be suitable for operating on 415±10% 50 cycles. 3 phase AC supply and soft starter. Refrigerant used shall be Ozone friendly HFC R134a/ R 1233ZD as per specifications. Chiller for air conditioning system shall be selected on the design basis as given below condition. The chiller Microprocessor shall be suitable for BMS integration and provided with suitable protocal. Chillers capacity of each chilling unit will be as follows: Rate shall inclusive of factory witness test as specified in the technical specification.

4

-

-

... More
a). Open/ Semi-Hermetic/ Fully hermetic Centrifugal Compressor complete with automatic capacity control system, safety switches, speed increasing gears, forced feed lubrication system etc. as per detailed specifications and compressor extended warranty of 1 year for refrigerent leakage & mechanical seal.

-

-

-

... More
b). Suitable capacity TERC/SPDP Squirrel Cage Induction Motor with enclosure IP 23/ as per OEM standard & class 'F' insulation suitable for operation on 415±10% Volt, 3 Phase, 50 HZ, AC Supply. Vendor must provide Junction box along with each set of unit including cable works from juction box to chiller.

-

-

-

... More
c) Unit Mounted/ Free standing IP-54 protection (UL /EN certified) VFD Starter panel with air Cooled/ Refrigerant Cooled or as per OEM standard, suitable for compressor motor, complete having over-load protection, under-voltage protection, protection against phase reversal, current sensing independent single phasing protection etc. including multi-function meter and CTs, complete as per detailed specifications. VFDs shall comply with IEC 61800-3 & have THD less than 5% at all Loads Active / passive filters must be use to achieve desired THD levels which will be in scope of Drive authorized supplier of OEM as per list of approved make. IEEE - 519 - 2014 standard is to be followed for harmonic control. VFDs shall be compatible for Modbus/Backnet Protocols. The power factor shall be 0.95 at all loads. Additional capacitor banks cost must be included in chiller price if power factor is less than 0.95. In Case of free standing VFD , One chiller is to be tested with VFD in factory for factory Test and same VFD model is to be used for remaining chillers. OEM shall stamp quality control clearance for each set of chiller & VFD before dispatch. Vendor shall provide data regarding losses in VFD and Active hormonic filters either on AHRI selection sheet or directly from respective OEM.Chiller performance i.e. IKW/TR value shall be considering VFD and Active harmonic filter losses.

-

-

-

... More
d). Lubrication Device consisting of automatic electric oil pump, oil cooler, head tank, oil strainer, automatic pressure regulating valve, oil heater, thermal switch etc, as per detailed specifications and as required -- 1 Set

-

-

-

... More
e). Matching Shell and Tube Water Cooled Condenser of M.S. Shell and integrally finned Copper Tubes, 2 pass heat exchanger.The Condenser shall have U- stamping / PED Certification Note- In case of R514a refrigerant, the relaxation on U stamping is applicable only after providing proper justification / proof documentation from OEM.

-

-

-

... More
f). Matching Shell and Tube Flooded type Chiller for centrifugal unit consisting of MS Shell and Copper Tubes, 2 pass Heat Exchanger, duly insulated at factory complete as per specifications and as required. The Evaporator shall have U- stamping.

-

-

-

... More
g). Refrigerant Line Accessories comprising of safety valves, angle valve, liquid line indications, liquid level control, liquid line isolation valve, etc. OR as per OEM design standard complete as per specifications -- 1 Lot

-

-

-

... More
h). DP/ Water Flow Switches at inlet and outlet of the condenser & chiller, water drain & air purge valves wherever required, complete as per specifications -- 1 Lot

-

-

-

... More
i). Suction Line and Chiller Insulation with minimum 19mm thick elastomeric nitrile rubber insulation complete as required from factory -- 1 Lot

-

-

-

... More
j). Foundation Frame Work for mounting the above condenser, chiller, compressor and motor with base plate, panel complete with anti-vibration pads (set of spring type vibration isolators with isolation efficiency more than 90%. Numbers shall be as per OEM standards.), complete as per specifications -- 1 Lot

-

-

-

... More
k). Initial/ First Charge of Refrigerant Gas and Compressor Oil - 1 Lot

-

-

-

... More
l). Chiller shall be factory tested at 25%, 50%, 75% and 100% load at Constant Condenser Water inlet

-

-

-

... More
m). Each chiller shall be provided with set of grooved coupling along with the chiller for cooler and condenser inlet / outlet connection.

-

-

-

... More
n). Chiller OEM shall provide undertaking in the name of end user for providing support for maintenance & spare availability for next 15 yrs from the date of Handover

-

-

-

... More
o). Software Selection Sheet to be AHRI Certified based on latest version. Which can be varified online through AHRI website.

-

-

-

... More
p). Vendor shall provide sound performance data for all loads on AHRI selection sheet OR certified by reputed third party OR this data shall be available in their product catalogue. This data shall be provided as apart of chiller technical submittal.

-

-

-

... More
Chiller: Capacity - 475TR Chilled Water IN - 54°F . Chilled Water Out - 44°F Chilled Water Flow - 1140 USGPM or as required Fouling factor - 0.0001 FPS Units, Condenser: Condenser Water IN - 86.9 °F, Condenser Water OUT - 96.9 °F Condenser Water Flow - 1425 USGPM or as required Fouling factor - 0.00025 FPS Maximum Power Consumed at above conditions : Not more than 0.63 kW/ TR Minimum IPLV: 9.1 Min COP at AHRI conditions : 6.5

-

-

-

... More
CHILLER ATC - Supply, Installation, testing & Commissioning of Automatic Tube Cleaning system ( ATCS ) for 4 Nos. Chillers (1:1) shall include Touch Screen Graphical PLC, one injection/collection pump, actuator based valves and complete with all accessories and Low side activities of piping connections from Ball traps to Ball collectors and Chillers. The actuator based valves shall give signals to PLC of their functioning and all process of injection and collection should be shown on the PLC while in operation. The ATCS System can be individual to each chiller or may handle multiple chiller at a time. As per specification/drawings and as directed by PMC/Employer.

4

-

-

... More
AIR COOLED CHILLER - Design, Supply, installation, testing and commissioning of Air COOLED SCREW CHILLER . - multiple screw compressors, energy efficient IE4 motor, Air cooled condenser, flow switch at chiller , spring vibration isolators, integral refrigerant piping and wiring, grooved couplings at chilled water inlets & outlets, accessories as required and called for, automatic and safety controls mounted in central console panel and all mounted on a steel frame etc. Motor shall be suitable for operating on 415±10% 50 cycles. 3 phase AC supply. Refrigerant used shall be Ozone friendly HFC R134a/ R 1233ZD as per specifications. Chiller for air conditioning system shall be selected on the design basis as given below condition. The chiller Microprocessor shall be suitable for BMS integration and provided with suitable protocal. Chillers capacity of each chilling unit will be as follows: Rate shall inclusive of factory witness test as specified in the technical specification.

2

-

-

... More
a). Semi-Hermetic/ Fully hermetic Compressor complete with automatic capacity control system, safety switches, speed increasing gears, forced feed lubrication system etc. as per detailed specifications and compressor extended warranty of 1 year for refrigerent leakage & mechanical seal.

-

-

-

... More
b). Suitable capacity TEFC/SPDP Squirrel Cage Induction Motor with enclosure IP 23/ as per OEM standard & class 'F' insulation suitable for operation on 415±10% Volt, 3 Phase, 50 HZ, AC Supply. Vendor must provide Junction box along with each set of unit including cable works from juction box to chiller.

-

-

-

... More
c) Unit Mounted/ Free standing IP-54 protection (UL /EN certified) VFD Starter panel with air Cooled/ Refrigerant Cooled or as per OEM standard, suitable for compressor motor, complete having over-load protection, under-voltage protection, protection against phase reversal, current sensing independent single phasing protection etc. including multi-function meter and CTs, complete as per detailed specifications. VFDs shall comply with IEC 61800-3 & have THD less than 5% at all Loads Active / passive filters must be use to achieve desired THD levels which will be in scope of Drive authorized supplier of OEM as per list of approved make. IEEE - 519 - 2014 standard is to be followed for harmonic control. VFDs shall be compatible for Modbus/Backnet Protocols. The power factor shall be 0.95 at all loads. Additional capacitor banks cost must be included in chiller price if power factor is less than 0.95. In Case of free standing VFD , One chiller is to be tested with VFD in factory for factory Test and same VFD model is to be used for remaining chillers. OEM shall stamp quality control clearance for each set of chiller & VFD before dispatch. Vendor shall provide data regarding losses in VFD and Active hormonic filters either on AHRI selection sheet or directly from respective OEM.Chiller performance i.e. IKW/TR value shall be considering VFD and Active harmonic filter losses.

-

-

-

... More
d). Lubrication Device consisting of automatic electric oil pump, oil cooler, head tank, oil strainer, automatic pressure regulating valve, oil heater, thermal switch etc, as per detailed specifications and as required -- 1 Set

-

-

-

... More
e). Air Condenser integrally finned Copper Tubes and die formed aluminium fins.The Condenser shall have U- stamping / PED Certification. Coil shall be with anti-corrosive epoxy coating, suitable to operate in saline, coastal humid environment. Condenser fans shall be direct driven, heavy duty axial type. Note- In case of R514a refrigerant, the relaxation on U stamping is applicable only after providing proper justification / proof documentation from OEM.

-

-

-

... More
f). Shell and Tube Flooded type Chiller consisting of MS Shell and Copper Tubes, 2 pass Heat Exchanger, duly insulated at factory complete as per specifications and as required. The Evaporator shall have U- stamping.

-

-

-

... More
g). Refrigerant Line Accessories comprising of safety valves, angle valve, liquid line indications, liquid level control, liquid line isolation valve, etc. OR as per OEM design standard complete as per specifications -- 1 Lot

-

-

-

... More
h). DP/ Water Flow Switches at inlet and outlet of the condenser & chiller, water drain & air purge valves wherever required, complete as per specifications -- 1 Lot

-

-

-

... More
i). Suction Line and Chiller Insulation with minimum 19mm thick elastomeric nitrile rubber insulation complete as required from factory -- 1 Lot

-

-

-

... More
j). Foundation Frame Work for mounting the above condenser, chiller, compressor and motor with base plate, panel complete with anti-vibration pads (set of spring type vibration isolators with isolation efficiency more than 90%. Numbers shall be as per OEM standards.), complete as per specifications -- 1 Lot

-

-

-

... More
k). Initial/ First Charge of Refrigerant Gas and Compressor Oil - 1 Lot

-

-

-

... More
l). Chiller shall be factory tested at 25%, 50%, 75% and 100% load at Constant Condenser Water inlet

-

-

-

... More
m). Each chiller shall be provided with set of grooved coupling along with the chiller for cooler and condenser inlet / outlet connection.

-

-

-

... More
n). Chiller OEM shall provide undertaking in the name of end user for providing support for maintenance & spare availability for next 15 yrs from the date of Handover

-

-

-

... More
o). Software Selection Sheet to be AHRI Certified based on latest version. Which can be varified online through AHRI website.

-

-

-

... More
p). Vendor shall provide sound performance data for all loads on AHRI selection sheet OR certified by reputed third party OR this data shall be available in their product catalogue. This data shall be provided as apart of chiller technical submittal.

-

-

-

... More
Chiller Capacity : 150 TR at Design Condition Chiller Performance: 1.3 kW/TR FL and 1.1 kW/TR IPLV (max) at Design condition Chiller Side: Chiller Water in : 54 Deg F & Chiller Water out: 44 Deg F Ambient air temp 104 deg F Water Flow rate : 360 GPM Fouling factor : 0.0001 hr.sqft.degF/BTU Min COP at AHRI condition: 3.2 or above

-

-

-

... More
COOLING TOWER

-

-

-

... More
Design, Supply, installation, testing and commissioning of COOLING TOWER with BMS compatible VFD, Cross Flow or Counterflow, Induced Draft, Vertical Discharge Type, Twin Cell, FRP Cooling Tower complete with multiple motor, fan, film type Fill, other complete accessories as described in the technical specifications. It shall be designed with high efficiency drift eliminator. Vibration Isolators of spring open type designed to minimize any vibration from transmitting to other structures to be included in the scope of supply. Motors shall be suitable for 415 + 10%volt, 50 cycles 3phase power supply and IE4 efficiency type. The power Isolators (lockable type) at cooling tower enclosed in weather proof panel and required length of power cable from the starter panel to the equipment shall also be included. Cooling Tower for air conditioning system shall be selected on the basis of monsoon ambient condition. The heat rejection capacity of the cooling tower must be 1.25 times greater than the chiller capacity. The tower shall be CTI certified. Chiller Capacity : 475TR- (Cooling tower Capacity shall be in HRT) Water Flow Rate : 1425 USGPM Water Temp In & Out : 96.9 degF & 86.9 degF, Design wet bulb : 81.8 degF Approach : 5 Deg F

4

-

-

... More
CHILLER PLANT MANAGER

-

-

-

... More
Supply, Installation, testing & Commissioning of Chiller Plant Manager including LCD Display, DDC Controller with all instruments, accessories and interconnecting control & power cabling etc.,supporting & controlling the proposed chilled water system as per specification/drawings and as directed by PMC/Employer Following are the list of equipment - Chillers - 475 TR x 4 nos - Primary Chilled water Pumps - 4 nos - Secondary Chilled Water Pump - 4nos - Cooling Tower - 4 nos ( 2 fans each) - Condensor Pump - 4 nos - Motorized Butterfly Valve - 12 Nos - Auto Tube Cleaning - Pressurization Unit - Water level switches in cooling towers (4 Nos )

-

-

-

... More
CPM to control chiller plant as describe above

1

-

-

... More
Supply, Installation, testing & Commissioning of Chiller Plant Manager including LCD Display, DDC Controller with all instruments, accessories and interconnecting control & power cabling etc.,supporting & controlling the proposed chilled water system as per specification/drawings and as directed by PMC/Employer Following are the list of equipment - Chillers - 150 TR x 2 nos - Primary Chilled water Pumps - 2 nos - Secondary Chilled Water Pump - 2nos - Motorized Butterfly Valve - 4 Nos - Auto Tube Cleaning - Pressurization Unit

-

-

-

... More
CPM to control chiller plant as describe above

1

-

-

... More
CENTRIFUGAL VERTICAL INLINE PUMPS

-

-

-

... More
CONSTANT FLOW PRIMARY CHILLED WATER PUMPS Flow Rate : 1140 GPM Head : 12 m of H2O a. Supply, Installation, testing & Commissioning of following capacity primary chilled water pump set given here under the scope of work shall include Lifting, shifting & positioning of the equipment comprising of the following and complete as per specification/drawings and as directed by PMC/Employer. All Pumps selection to be verified by HVAC Contractor for parallel pumping operation with one, two or all pumps working All Pump shall be supplied with Suction Guide of 200mm Diameter.

4

-

-

... More
b. Single stage centrifugal coupled type INLINE pumpset with axial suction port and discharge port (with Bacnet MS/TP communication protocol), bronze impeller, mechanical seal & Suction guide.

-

-

-

... More
c. The noise level shall be limited to 70 dBA at a distance of 1.5 m, Minimum pump efficiency should not be less than 85% & pumping power must not exceed 22 W/gpm, Motor efficieny not less than 90% (IE-4). Suitable HP,motor shall be TEFC squirrel cage type motors with IP55 protection.

-

-

-

... More
d. Couplings shall be split to allow removal from pump and motor shafts, leaving space between the shafts sufficient to replace all mechanical seal components without disturbing the pump or motor.

-

-

-

... More
e. The duty point of the pump shall be defined in the pump curve

-

-

-

... More
f. Insulation for chilled water pumps to be 32mm nitrile rubber of minimum density 40kg/m3, thermal conductivity of 0.032W/mK at 25 Deg C, covered with 500 GSM two layer vapour barrier and covered with 26 G Aluminium cladding.

-

-

-

... More
g. Head Indicated below is tentative , Contractor shall submit Pump static head calculations based on approved shop drawings before ordering the pumps. Any rise in head required shall be offer by contractor without any additional cost. Note- "The Variation in Static Head Rise more than 20% will only be consider for Extra item, If there is change in layout w.r.t Tender drawing."

-

-

-

... More
h. Pump design parameter / motor rating furnished in the BOQ is of indicative in nature. If the actual parameter required to meet the proposed HVAC system, then the same shall be provided by HVAC Contractor based on the final pump/motor selection without any cost implication to the Owner.

-

-

-

... More
VARIABLE SECONDARY CHILLED WATER PUMPS Flow Rate : 1140 GPM Head : 30 m of H2O a. Supply, Installation, testing & Commissioning of following capacity variable secondary chilled water pump set given here under the scope of work shall include Lifting, shifting & positioning of the equipment comprising of the following and complete as per specification/drawings and as directed by PMC/Employer. All Pumps selection to be verified by HVAC Contractor for parallel pumping operation with one, two or all pumps working

4

-

-

... More
b. Single stage centrifugal coupled type INLINE pumpset with axial suction port and discharge port (with Bacnet MS/TP communication protocol), bronze impeller, mechanical seal & Suction guide.

-

-

-

... More
c. The noise level shall be limited to 70 dBA at a distance of 1.5 m, Minimum pump efficiency should not be less than 85% & pumping power must not exceed 22 W/gpm, Motor efficieny not less than 90% (IE-4). Suitable HP,motor shall be TEFC squirrel cage type motors with IP55 protection.

-

-

-

... More
d. Couplings shall be split to allow removal from pump and motor shafts, leaving space between the shafts sufficient to replace all mechanical seal components without disturbing the pump or motor.

-

-

-

... More
e. The duty point of the pump shall be defined in the pump curve

-

-

-

... More
f. Insulation for chilled water pumps to be 32mm nitrile rubber of minimum density 36kg/m3, thermal conductivity of 0.032W/mK at 25 Deg C, covered with 500 GSM two layer vapour barrier and covered with 26 G Aluminium cladding.

-

-

-

... More
g VFD - The variable frequency drive(s) shall be pulse width modulation (PWM) type, microprocessor controlled design. VFD shall be capable of operating in voltage ranges of 380 to 415 V +/- 10% AC, three phase; at frequencies of 48 to 63 Hz. VFD shall be factory fitted and unit mounted. The control should be a low harmonic control with a built-in DC link reactor equivalent in performance to a 5% AC line reactor.VFDs shall comply with IEC 61800-3 & have THD less than 5%. Active / passive filters must be use toachieve desired THD levels which will be in scope of Drive authorized supplier of OEM as per list of approved make. IEEE - 519 - 2014 standard is to be followed for harmonic control. VFDs shall be motor mounted and IP 54 rated.

-

-

-

... More
h. Head Indicated below is tentative , Contractor shall submit Pump static head calculations based on approved shop drawings before ordering the pumps. Any rise in head required shall be offer by contractor without any additional cost. Note- "The Variation in Static Head Rise more than 20% will only be consider for Extra item, If there is change in layout w.r.t Tender drawing."

-

-

-

... More
i. Pump design parameter / motor rating furnished in the BOQ is of indicative in nature. If the actual parameter required to meet the proposed HVAC system, then the same shall be provided by HVAC Contractor based on the final pump/motor selection without any cost implication to the Owner.

-

-

-

... More
CONDENSER WATER PUMPS Flow Rate : 1425 GPM Head : 25 m of H2O a. CONDENSER PUMPS with BMS compatible VFD- Supply, Installation, testing & Commissioning of following capacity condenser water pump set given here under the scope of work shall include Lifting, shifting & positioning of the equipment comprising of the following and complete as per specification/drawings and as directed by PMC/Employer. All Pumps selection to be verified by HVAC Contractor for parallel pumping operation with one, two or all pumps working

4

-

-

... More
b. Single stage centrifugal coupled type INLINE pumpset with axial suction port and discharge port (with Bacnet MS/TP communication protocol), bronze impeller, mechanical seal & Suction guide.

-

-

-

... More
c. The noise level shall be limited to 70 dBA at a distance of 1.5 m, Minimum pump efficiency should not be less than 85% & pumping power must not exceed 19 W/gpm, Motor efficieny not less than 90% (IE-4). Suitable HP,motor shall be TEFC squirrel cage type motors with IP55 protection.

-

-

-

... More
d. Couplings shall be split to allow removal from pump and motor shafts, leaving space between the shafts sufficient to replace all mechanical seal components without disturbing the pump or motor.

-

-

-

... More
e. The duty point of the pump shall be defined in the pump curve

-

-

-

... More
f. Head Indicated below is tentative , Contractor shall submit Pump static head calculations based on approved shop drawings before ordering the pumps. Any rise in head required shall be offer by contractor without any additional cost. Note- "The Variation in Static Head Rise more than 20% will only be consider for Extra item, If there is change in layout w.r.t Tender drawing."

-

-

-

... More
g. Pump design parameter / motor rating furnished in the BOQ is of indicative in nature. If the actual parameter required to meet the proposed HVAC system, then the same shall be provided by HVAC Contractor based on the final pump/motor selection without any cost implication to the Owner.

-

-

-

... More
SECONDARY PUMP PANEL Design, Supply, installation, testing and commissioning of water cooled chilled water Pump Starter Panel cum Logic controller panel with all necessary power & control circuit breakers, contactors, SPPR, auto/manual selector switches, earthing and internal power & control cabling, terminations with necessary lugs and glands, etc. , Microprocessor based logic controller, integrated Software capable to control frequency based on the inputs from sensors, 4 Nos of differential pressure sensor & transmitters, power cable from panel to pump, ON/OFF push button, communication cable, Communication card (BACnet protocol) to transfer the entire data available on unit mounted VFD (4 in Secondary pumps) to the third party BMS System. The Cost shall include 5 Nos. DPT for each pump.

1

-

-

... More
CONSTANT PRIMARY CHILLED WATER PUMPS Flow Rate : 360 GPM Head : 15 m of H2O a. Supply, Installation, testing & Commissioning of following capacity primary chilled water pump set given here under the scope of work shall include Lifting, shifting & positioning of the equipment comprising of the following and complete as per specification/drawings and as directed by PMC/Employer. All Pumps selection to be verified by HVAC Contractor for parallel pumping operation with one, two or all pumps working.

2

-

-

... More
b. Single stage centrifugal coupled type INLINE pumpset with axial suction port and discharge port (with Bacnet MS/TP communication protocol), bronze impeller & mechanical seal

-

-

-

... More
c. The noise level shall be limited to 70 dBA at a distance of 1.5 m, Minimum pump efficiency should not be less than 85% & pumping power must not exceed 22 W/gpm, Motor efficieny not less than 90% (IE-4). Suitable HP,motor shall be TEFC squirrel cage type motors with IP55 protection.

-

-

-

... More
d. Couplings shall be split to allow removal from pump and motor shafts, leaving space between the shafts sufficient to replace all mechanical seal components without disturbing the pump or motor.

-

-

-

... More
e. The duty point of the pump shall be defined in the pump curve

-

-

-

... More
f. Insulation for chilled water pumps to be 32mm nitrile rubber of minimum density 36kg/m3, thermal conductivity of 0.032W/mK at 25 Deg C, covered with 500 GSM two layer vapour barrier and covered with 26 G Aluminium cladding.

-

-

-

... More
g. Head Indicated below is tentative , Contractor shall submit Pump static head calculations based on approved shop drawings before ordering the pumps. Any rise in head required shall be offer by contractor without any additional cost. Note- "The Variation in Static Head Rise more than 20% will only be consider for Extra item, If there is change in layout w.r.t Tender drawing."

-

-

-

... More
h. Pump design parameter / motor rating furnished in the BOQ is of indicative in nature. If the actual parameter required to meet the proposed HVAC system, then the same shall be provided by HVAC Contractor based on the final pump/motor selection without any cost implication to the Owner.

-

-

-

... More
VARIABLE SECONDARY CHILLED WATER PUMPS Flow Rate : 360 GPM Head : 30 m of H2O a. Supply, Installation, testing & Commissioning of following capacity variable secondary chilled water pump set given here under the scope of work shall include Lifting, shifting & positioning of the equipment comprising of the following and complete as per specification/drawings and as directed by PMC/Employer. All Pumps selection to be verified by HVAC Contractor for parallel pumping operation with one, two or all pumps working

2

-

-

... More
b. Single stage centrifugal coupled type INLINE pumpset with axial suction port and discharge port (with Bacnet MS/TP communication protocol), bronze impeller & mechanical seal

-

-

-

... More
c. The noise level shall be limited to 70 dBA at a distance of 1.5 m, Minimum pump efficiency should not be less than 85% & pumping power must not exceed 22 W/gpm, Motor efficieny not less than 90% (IE-4). Suitable HP,motor shall be TEFC squirrel cage type motors with IP55 protection.

-

-

-

... More
d. Couplings shall be split to allow removal from pump and motor shafts, leaving space between the shafts sufficient to replace all mechanical seal components without disturbing the pump or motor.

-

-

-

... More
e. The duty point of the pump shall be defined in the pump curve

-

-

-

... More
f. Insulation for chilled water pumps to be 32mm nitrile rubber of minimum density 36kg/m3, thermal conductivity of 0.032W/mK at 25 Deg C, covered with 500 GSM two layer vapour barrier and covered with 26 G Aluminium cladding.

-

-

-

... More
g VFD - The variable frequency drive(s) shall be pulse width modulation (PWM) type, microprocessor controlled design. VFD shall be capable of operating in voltage ranges of 380 to 415 V +/- 10% AC, three phase; at frequencies of 48 to 63 Hz. VFD shall be factory fitted and unit mounted. The control should be a low harmonic control with a built-in DC link reactor equivalent in performance to a 5% AC line reactor.VFDs shall comply with IEC 61800-3 & have THD less than 5%. Active / passive filters must be use toachieve desired THD levels which will be in scope of Drive authorized supplier of OEM as per list of approved make. IEEE - 519 - 2014 standard is to be followed for harmonic control. VFDs shall be motor mounted and IP 54 rated.

-

-

-

... More
h. Head Indicated below is tentative , Contractor shall submit Pump static head calculations based on approved shop drawings before ordering the pumps. Any rise in head required shall be offer by contractor without any additional cost. Note- "The Variation in Static Head Rise more than 20% will only be consider for Extra item, If there is change in layout w.r.t Tender drawing."

-

-

-

... More
i. Pump design parameter / motor rating furnished in the BOQ is of indicative in nature. If the actual parameter required to meet the proposed HVAC system, then the same shall be provided by HVAC Contractor based on the final pump/motor selection without any cost implication to the Owner.

-

-

-

... More
Design, Supply, installation, testing and commissioning of air cooled chilled water Pump Starter Panel cum Logic controller panel with all necessary power & control circuit breakers, contactors, SPPR, auto/manual selector switches, earthing and internal power & control cabling, terminations with necessary lugs and glands, etc. , Microprocessor based logic controller, integrated Software capable to control frequency based on the inputs from sensors, 4 Nos of differential pressure sensor & transmitters, power cable from panel to pump, ON/OFF push button, communication cable, Communication card (BACnet protocol) to transfer the entire data available on unit mounted VFD (2 in Secondary pumps) to the third party BMS System.

1

-

-

... More
AIR HANDLING UNIT:

-

-

-

... More
Supply, installation testing & commissioning EUROVENT CERTIFIED Horizontal / vertical floor mount Airhandling units having following specifications. a. Frame Structure consisting of 45mm Extruded Aluminium Thermal break profile Panel: 45mm +/- 2mm thick double skin sandwich panels with Puff insulation of density 48 kg/cum , The sheet thickness shall be minimum 0.8 mm for the outer skin and 0.8 mm thickness for the inner skin of GI . b. Filtration Section shall be provided with 2 stage washable type of 'ISO Coarse Grade / MERV 8 ' first stage and 'ISO PM 2.5 /MERV 13' final stage with velocity less than equal to 500 FPM. c. Coil Section: Chilled water coil Min. 6 row deep constructed with Aluminium fins of minimum 0.11mm thickness and copper tubes of minimum 29 Guage thickness. Copper tube shall be 12.5mm diameter. The coil face area shall not exceed 2.5m/sec. Coil face velocity shall be kept 500 FPM, Coil shall have hydrophilic coating & SS End Plates: - Material of Tube - Copper, - Chilled Water inlet/ outlet temperature - 7.2°C (45°F) / 12.7°C (55°F) Coil shall be provided with copper header. d. Inbuilt UV Lamp to be considered upstream or downstream of the coil based on OEM recommendation with necessary interlock with the AHU whenver the AHU is shutoff, UV lamp shall be off and vice versa. e. Drain Pan: Condensate drain pan shall be fabricated from 20 G SS 304 powder coated, insulated with 19 mm thick closed cell elastomeric insulation. f. Fan Section: Direct drive backward curved EC fan ( Electronically commutated ) with permanent magnet brushless DC motor for stepless variation of speed of fan based on temperature sensor inputs. The fan section shall be provided with limt switch for safety to shut off fan during Opening of access door.

-

-

-

... More
AHU fan capacity shall be selected at 90% of fan speed, unit outlet velocity should not exceeding 2000 FPM & min fan efficiency preferrably should be 70% and in case if 70% is not achievable, Fans should be selected for maximum possible efficiency. Max. noise level of unit shall be 70 dBA at 1.5 meter. Fan power should not exceed 0.0005 BHP / CFM. Mechanical performance of AHU casing shall be tested as per EN1886 or AHRI 1350 or ISHRAE standard by internationally renowned laboratory or certification body like AHRI/ Eurovent/ Intertek / UL and should meet the following characteristics: As per EN 1886 As per AHRI 1350 As per ISHRAE Standard Mechanical Strength D1 CD 4 M1 Thermal Bridging TB2 CB 2 TB 2 Thermal Transmittance T2 CT 2 T 2 Air Leakage L1 CL 6 CL 1

-

-

-

... More
AHU mounted graphical display with starter Panel with Auto /Manual switch and incomer power terminal. all internal cablings between panel and motor/ door interlocks / marine lamp etc should be considered Instrumentation Kit to be provided to give out the following option 1. Supply air temperature 2. Return air temperature 3. Chilled water in temperature 4. Chilled water out temperatue 5. DP switch across filter for fitler clog Controller module with RS 485 port compatible with BMS, on board protocol with touch screen to display following 1. EC fan operation status 2. Chilled water valve operation status 3. AHU Airflow ( CFM) 4. AHU power consumption 5. Chilled water in/out Temp 6. Common Alarm Controller shall also have fire trip alarm to shut AHU incase of signal from fire panel

-

-

-

... More
20500 CFM ESP 45 MM

1

-

-

... More
15400 CFM ESP 30 MM

5

-

-

... More
12200 CFM ESP 30 MM

14

-

-

... More
8300 CFM ESP 30 MM

1

-

-

... More
7100 CFM ESP 30 MM

39

-

-

... More
Supply, Installation, Testing & Commissioning of Spare EC Fans to be Considered for Overall 10% of the Quantity of All Equipment

1

-

-

... More
Ceiling Suspended Air Handling Unit

-

-

-

... More
Supply, installation testing & commissioning EUROVENT CERTIFIED CSU Airhandling units having following specifications. a. Frame Structure consisting of 45mm Extruded Aluminium Thermal break profile Panel: 45mm +/- 2mm thick double skin sandwich panels with Puff insulation of density 48 kg/cum , The sheet thickness shall be minimum 0.8 mm for the outer skin and 0.8 mm thickness for the inner skin of GI . b. Filtration Section shall be provided with 2 stage washable type of 'MERV8 ' first stage and 'MERV13' final stage with velocity less than equal to 500 FPM. c. Coil Section: Chilled water coil Min. 6 row deep constructed with Aluminium fins of minimum 0.11mm thickness and copper tubes of minimum 29Guage thickness. Copper tube shall be 9.6mm or 12.5mm diameter. The coil face area shall not exceed 2.5m/sec. Coil face velocity shall be kept 500 FPM, Coil shall have hydrophilic coating & SS End Plates: - Material of Tube - Copper, - Chilled Water inlet/ outlet temperature - 7.2°C (45°F)/ 12.7°C (55°F) Coil shall be provided with copper header. d. Inbuilt UV Lamp to be considered upstream or downstream of the coil based on OEM recommendation with necessary interlock with the AHU whenver the AHU is shutoff, UV lamp shall be off and vice versa. e. Drain Pan: Condensate drain pan shall be fabricated from 20 G SS 304 powder coated, insulated with 19 mm thick closed cell elastomeric insulation. f. Fan Section: Direct drive backward curved EC fan ( Electronically commutated ) with permanent magnet brushless DC motor for stepless variation of speed of fan based on temperature sensor inputs. The fan section shall be provided with limt switch for safety to shut off fan during Opening of access door.

-

-

-

... More
AHU fan capacity shall be selected at 100% of fan speed, unit outlet velocity should not exceeding 2000 FPM & min fan efficiency preferrably should be 70% and in case if 70% is not achievable, Fans should be selected for maximum possible efficiency. Max. noise level of unit shall be 70 dBA at 1.5 meter. Fan power should not exceed 0.0003 BHP / CFM. Mechanical performance of AHU casing shall be tested as per EN1886 or AHRI 1350 or ISHRAE standard by internationally renowned laboratory or certification body like AHRI/ Eurovent/ Intertek / UL and should meet the following characteristics: As per EN 1886 As per AHRI 1350 As per ISHRAE Standard Mechanical Strength D1 CD 4 M1 Thermal Bridging TB2 CB 2 TB 2 Thermal Transmittance T2 CT 2 T 2 Air Leakage L1 CL 6 CL 1

-

-

-

... More
Instrumentation Kit to be provided to give out the following option 1. Supply air temperature 2. Return air temperature 3. Chilled water in temperature 4. Chilled water out temperatue 5. DP switch across filter for fitler clog Controller module with RS 485 port compatible with BMS, on board protocol with touch screen to display following. Control module shall be located in a sperate control panel located on the nearest wall or at the location as defined by client /PMC 1. EC fan operation status 2. Chilled water valve operation status 3. AHU Airflow ( CFM) 4. AHU power consumption 5. Chilled water in/out Temp 6. Common Alarm Controller shall also have fire trip alarm to shut AHU incase of signal from fire panel Unit height should not exceed 750 mm, accordinlgy CSU dimension and fan selection to be considered.

-

-

-

... More
2000 CFM ESP 15 MM

1

-

-

... More
2500 CFM ESP 15 MM

1

-

-

... More
3000 CFM ESP 15 MM

10

-

-

... More
3500 CFM ESP 15 MM

5

-

-

... More
4000 CFM ESP 30 MM

2

-

-

... More
4500 CFM ESP 15 MM

5

-

-

... More
5000 CFM ESP 15 MM

1

-

-

... More
5500 CFM ESP 15 MM

1

-

-

... More
6000 CFM ESP 15 MM

1

-

-

... More
6500 CFM ESP 15 MM

1

-

-

... More
7000 CFM ESP 30 MM

4

-

-

... More
TREATED FRESH AIR UNITS WITH HEAT RECOVERY WHEEL

-

-

-

... More
Supply, installation testing & commissioning EUROVENT CERTIFIED Treated Fresh Air Unit with Heat Recovery Wheel having following specifications. Unit Shall be with two stream (with separate fan sets) unit in double skin construction, comprising of supply air section, return air section, chiiled water coil section, filter section, limit switch, drain connections, purge section and energy recovery Enthalpy wheel section. Supply ,Fresh air, return air and exhaust air Al. dampers a. Frame Structure consisting of 45mm Extruded Aluminium Thermal break profile Panel: 45mm +/- 2mm thick double skin sandwich panels with Puff insulation of density 48 kg/cum , The sheet thickness shall be minimum 0.8 mm for the outer skin and 0.8 mm thickness for the inner skin of GI. b. Filtration Section shall be provided with 2 stage washable type of 'MERV8 ' first stage and 'MERV13' final stage with velocity less than equal to 500 FPM. c. Coil Section: Chilled water coil Min. 8 row deep constructed with Aluminium fins of minimum 0.11mm thickness and copper tubes of minimum 29Guage thickness. Copper tube shall be 9.6mm or 12.5mm diameter. The coil face area shall not exceed 2.5m/sec. Coil face velocity shall be kept 500 FPM, Coil shall have hydrophilic coating & SS End Plates: - Material of Tube - Copper, - Chilled Water inlet/ outlet temperature - 7.2°C (45°F)/ 12.7°C (55°F) Coil shall be provided with copper header. d. Inbuilt UV Lamp to be considered upstream or downstream of the coil based on OEM recommendation with necessary interlock with the TFA whenver the TFA is shutoff, UV lamp shall be off and vice versa. e. Drain Pan: Condensate drain pan shall be fabricated from 20 G SS 304 powder coated, insulated with 19 mm thick closed cell elastomeric insulation. f. Energy Recovery Wheel shall be as per DIN EN ISO 846.Min. Total recovery Efficiency (both sensible & latent) should be minimum 75% Wheel shall be AHRI Certified. necessary software selection of the wheel has to be enclosed to justify the pressure drop and efficiency calculations

-

-

-

... More
g. Fan Section: Direct drive backward curved EC fan ( Electronically commutated ) with permanent magnet brushless DC motor for stepless variation of speed of fan based on temperature sensor inputs. The fan section shall be provided with limt switch for safety to shut off fan during Opening of access door. h. The exhaust fan section can be fixed speed but selected at 80% fan speed to avoid breakdown problems. The fans need to achieve IE-4 Motor Efficiency and fan power as per requirement stated below. h. Canopy to be provided for all TFA Outdoor Unit.

-

-

-

... More
TFA fan capacity shall be selected at 100% of fan speed, unit outlet velocity should not exceeding 2000 FPM & min fan efficiency preferrably should be 70% and in case if 70% is not achievable, Fans should be selected for maximum possible efficiency. Max. noise level of unit shall be 75 dBA at 1.5 meter. Fan power should not exceed 0.0005 BHP / CFM. Mechanical performance of TFA casing shall be tested as per EN1886 or AHRI 1350 or ISHRAE standard by internationally renowned laboratory or certification body like AHRI/ Eurovent/ Intertek / UL and should meet the following characteristics: As per EN 1886 As per AHRI 1350 As per ISHRAE Standard Mechanical Strength D1 CD 4 M1 Thermal Bridging TB2 CB 2 TB 2 Thermal Transmittance T2 CT 2 T 2 Air Leakage L1 CL 6 CL 1

-

-

-

... More
Instrumentation Kit to be provided to give out the following option 1. Supply air temperature 2. Return air temperature 3. Chilled water in temperature 4. Chilled water out temperatue 5. DP switch across filter for fitler clog Controller module with RS 485 port compatible with BMS, on board protocol with touch screen to display following. Control module shall be located in a sperate control panel located on the nearest wall or at the location as defined by client /PMC 1. EC fan operation status 2. Chilled water valve operation status 3. TFA Airflow ( CFM) 4. TFA power consumption 5. Chilled water in/out Temp 6. Common Alarm Controller shall also have fire trip alarm to shut AHU incase of signal from fire panel

-

-

-

... More
Heat recovery wheel, located between fresh air and exhaust air streams to reduce the fresh Air load. Efficiency of Heat recovery unit =75%. The desiccant of the wheel shall be Molecular Sieve 3 Angstrom to avoid any sort of cross contamination between the two air streams. The Wheel shall be AHRI certified in accordance with standard 1060 and carry the AHRI certification stamp.

-

-

-

... More
HRW-1 FA - 16,900 CFM ESP 35 MM EA - 12,500 CFM ESP 30 MM

1

-

-

... More
HRW-2 FA - 16,300 CFM ESP 35 MM EA - 9,500 CFM ESP 30 MM

1

-

-

... More
HRW-3 FA - 16,300 CFM ESP 35 MM EA - 12,500 CFM ESP 30 MM

1

-

-

... More
HRW-4 FA - 16,900 CFM ESP 35 MM EA - 9,500 CFM ESP 30 MM

1

-

-

... More
30,000 CFM ESP 40 MM - Lobby TFA - Without Heat Recovery Wheel

1

-

-

... More
7,500 CFM ESP 30 MM - Cafe TFA - Without Heat Recovery Wheel

1

-

-

... More
Chilled Water Cassette

-

-

-

... More
CHILLED WATER CASSETTES along with Chilled Water Valve package consisting of 1 Ball valve with and 1 without strainer and PIBCV self dynamic balancing cum control valve for CHW flow control and all accessories required shall be part of scope. MS to Copper connectors required to connect from the main CHW MS pipeline before connecting to unit. Digital wireless remote shall be part of scope.Unit should be with Inbuilt Drain Pump. Factory assembled valve station of Linear Characteristic PICV as per required dia with PT port & diaphragm, Test Point, Filter Ball Valve & Bypass Valve arrangement with Insulation Kit & Modulating Electromotive Actuator (Non Spring Return) with BMS Compatible & with Flexible Hoses Valve staton shall be located in a drip tray made of 22 G GI sheet insulated from the bottom of the sheet, tray shall be provided with a height of 50 mm minum and length/width shall be able to cover the entire valve station. UNIT shall be wth inbuilt BMS compatibility with Modbus RS485 protocol output. Unit shall swicth on/off based on remote on/off command & status.

-

-

-

... More
0.8 TR ( Four way cassette)

1

-

-

... More
1.0 TR ( Four way cassette)

1

-

-

... More
1.5 TR ( Four way cassette)

1

-

-

... More
2.0 TR ( Four way cassette)

1

-

-

... More
Fan Coil Units

-

-

-

... More
Supply, Installation, testing & commissioning of factory built FAN COIL UNITS double skin made up of minimum 0.8mm sheets, blow through type, each complete with 3-4 rows deep chilled water coil of copper tube with aluminium fins construction with hydrophilic coating as specified and shown in the drawing, data sheets etc. consisting of: i) Supply & Installation of 2-way motorized PIBC valve with actuator, 2 Nos extended stem ball valves, one of them with strainer. Diameter shall be as per Unit Capacity. ii) Supply & Installation of compatible room thermostat iii) Supply & Installation of Power wiring from the 5A switch socket within 2 meter along with a 5A plug top iv) Supply & Installation of Halogen Free control wiring (10C, 1.5 sq.mm) between the unit and thermostat including 25mm dia pvc conduit v) Supply & Installation of Supporting frame and suspenders vi) Supply & Installation of Earthing of motor and unit. vii) Installation of pipe (CHWS & CHWR) & 19mm thk Class 0 nitrile rubber insulation from main riser / header to the unit viii) Extended drain pan SS316, double skin with insulation. ix) Canvas connection (Fire retardant) at FCU outlet. x) 4-speed DC motor with direct drive Final connection to the FCU valve station from main chilled water tapping shall be completed with flexible composite pipe (upon approval) with its all accessories.Fan power should not exceed 0.0003 BHP / CFM.

-

-

-

... More
600 CFM 7mm ESP

2

-

-

... More
900 CFM 7mm ESP

1

-

-

... More
1000 CFM 7mm ESP

1

-

-

... More
1200 CFM 10mm ESP

28

-

-

... More
1400 CFM 10mm ESP

1

-

-

... More
Chilled Water Hi-Wall Unit

-

-

-

... More
Supply, installation, testing & commissioning of Chilled water type Hi-wall unit with Fan, Motor having Hi-medium-Low speed,, CHW cooling Coil of sutable RD ,Filter , controls, decorative panel & power wiring from nearest power socket to indoor unit.The units should be suitable for 10 ºF Δ T ( CHW inlet temperature should be 44 ºF and outlet should be 54 ºF, Should be inclusive with valve Kit (1 Ball valve with y strainer in the supply side & 1 Ball valve with 2 Way Control Valve in the Return Line) & should include flexible CU hose to connect the chilled water pipe line to the valve Kit.

-

-

-

... More
0.75 TR Hi wall unit

1

-

-

... More
1.0 TR Hi wall unit

2

-

-

... More
1.5 TR Hi wall unit

1

-

-

... More
1.8 TR Hi wall unit

2

-

-

... More
2.0 TR Hi wall unit

1

-

-

... More
DX SYSTEM

-

-

-

... More
Hi-wall Units

-

-

-

... More
Supply, Installation, testing & Commissioning of 5 Star, BEE rating (nominal capacity) Air-cooled inverter type split type AC unit along with indoor/outdoor units, refrigerent type R-410a or R-32, controls suitable to operate on 230 Volts 50 Hz AC supply etc. complete as required including voltage stabiliser of suitable rating to give constant output of 230V for input range of 180 V to 260 V with time delay, high/low cut off, meter to read input and output voltages, ON/OFF switches etc. as required. Quoted price shall include cost of wireless remote controller, cooling thermostat, refrigerant filling. Unit shall be provided with auto timer setting. As per technical specifications with all the necessary mounting accessories as required for complete installation. The noise level of Hi - Wall indoor unit shall not be more than 35 dB (A) at 1.5 meter distance. As per specification/drawings and as directed by PMC/Employer.

-

-

-

... More
1.0 TR

1

-

-

... More
1.5 TR

2

-

-

... More
2.0 TR

1

-

-

... More
AIR COOLED VARIABLE REFRIGERANT FLOW/ VOLUME (VRF/ VRV) SYSTEM

-

-

-

... More
VRV/VRF OUTDOOR AC UNIT:

-

-

-

... More
Supply, Installation, testing & Commissioning of modular type Variable Refrigerant Flow/ Variable Refrigerant Volume aircooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), minimum two compressors for above 14HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R407c/R410a/EQUIVALENT Refrigerant, vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V+/-10%, 3Phase, 50Hz AC power supply. The unit shall be filled with firs tcharge of the refrigerant and ready for use as required. - The COP at AHRI conditions shall not be less than 3.6 - IEER not less than 6.5 . Unit shall include support stand with two coat of enmel panint as per specification. Offered ODU model shall be with highest possible COP by OEM Include Lifting, shifting, assemblling & positioning of the equipment comprising of the following and complete as per specification/drawings and as directed by PMC/Employer

-

-

-

1

-

-

1

-

-

... More
VRF/VRV INDOOR AC UNIT (INDOOR UNIT- CASSETTE TYPE):

-

-

-

... More
Supply, installation, testing and commissioning of following minimum capacity VRV/VRF Cassette Unit type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multi speedmotor, coilsection with DX coppercoil, electronic expansion valve, outer cabinet with grills, drain pump, cordless remote control, drain pan, necessary accessories etc., suitable for operation on 230V±10%, 50Hz, single phase AC supply, completeas required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 22 Degree C DBT

-

-

-

1

-

-

... More
1.6 TR

4

-

-

2

-

-

... More
2.5 TR

1

-

-

1

-

-

... More
VRF/VRV INDOOR AC UNIT (HI-WALL):

-

-

-

... More
Supply,installation,testing and commissioning of following minimum capacity Hi-Wall Type Indoor Wall mounted unit equipped with synthetic washable media prefilter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil,electronic expansion valve, outer cabinet, grill, necessary supports, vibration isolation, cordless remote control etc., suitable for operation on single phase 230V±10%, 50 Hz AC supply, complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will beat air inlet conditions of 22 Degree C DBT.Sound Pressure levels for High wall Unit shall not be more than 32 dB(A)

-

-

-

1

-

-

... More
1.6 TR

4

-

-

2

-

-

... More
2.5 TR

1

-

-

1

-

-

... More
VRF/VRV INDOOR AC UNIT (DUCTABLE UNITS):

-

-

-

... More
Supply, installation, testing and commissioning of following minimum capacity and external static pressure VRF/VRV ceiling mounted ductable type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, corded remote control, outer cabinet, vibration isolators, drain pan, other necessary supports etc., suitable for operation on single phase AC supply 230V±10%, 50Hz complete as required. The unit shall have automatic force shutdown provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 22 Degree C DBT. Low static ductable units (minimum 30 pascal external static pressure)

-

-

-

... More
1.6 TR - Low Static

1

-

-

... More
4.0 TR - Low Static

2

-

-

... More
7.1 TR - High Static - 7mm ESP

1

-

-

... More
8.0 TR - High Static - 7mm ESP

2

-

-

... More
COPPER REFRIGERANT PIPING:

-

-

-

... More
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/ hard drawn copper refrigerant piping for DX/VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/ brazing including cable trays & accessories, insulated with XPLE Class-O tubular insulation/ with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required :

-

-

-

... More
6.4 mm dia (OD) (Softdrawn) with tube thickness 1.2 mm with 19 mm thick insulation

6

-

-

... More
9.5 mm dia (OD) (Softdrawn) with tube thickness 1.2 mm with 19 mm thick insulation

20

-

-

... More
12.7 mm dia (OD) (Softdrawn) with tube thickness 1.2 mm with 19 mm thick insulation

31

-

-

... More
15.86 mm dia (OD) (Softdrawn) with tube thickness 1.2 mm with 19 mm thick insulation

8

-

-

... More
19.1 mm dia (OD) (Harddrawn) with tube thickness 1.2 mm with 19 mm thick insulation

15

-

-

... More
22.2 mm dia (OD) (Harddrawn) with tube thickness 1.2 mm with 19 mm thick insulation

12

-

-

... More
25.4 mm dia (OD) (Harddrawn) with tube thickness 1.2 mm with 19 mm thick insulation

6

-

-

... More
28.58 mm dia (OD) (Harddrawn) with tube thickness 1.2 mm with 19 mm thick insulation

22

-

-

... More
34.9 mm dia (OD) (Harddrawn) with tube thickness 1.62 mm with 19 mm thick insulation

12

-

-

... More
41.27 mm dia (OD) (Harddrawn) with tube thickness 1.62 mm with 19 mm thick insulation

6

-

-

... More
NOTE:-1) The Copper Piping & Piping Circuit should be with Minimum Number of joints, which shall be attained by : (i) Using One End Expanded Tubes (ii) Bending the tubes instead of using elbow joints wherever 90 degree bending is required.(2)Piping should be routed at site in such a manner, that brazed joints in the refrigeration piping are kept to a minimum.(3) The makes of tube fittings shall be same as that of tubes.(4) The thickness of fittings used shall be same as that of the pipe. (5) All insulation joints must be covered with EPDM Rubber Tape

-

-

-

... More
Protective Coating for Cu Pipe

-

-

-

... More
Supply & fixing of Mechanical + UV protective coating for Exposed copper piping insulation with 1 layer of glass cloth and UV paint. . The covering shall be provided with min 6-7 mil thickness and 200 gram/sqmt (±10%) interwoven glass fabric.

20

-

-

... More
Y JOINTS: Supply, installation, testing & commissioning of Ref Nut/Y-joints brass for indoor and outdoor units of suitable size as per requirement. As per specification/drawings and as directed by PMC/Employer.

6

-

-

... More
COMMUNICATION CABLE - Supply and laying, testing & commissioning of following sizes of Copper conductor control cables through PVC conduit on existing tray including fixing clamps & proper connections to equipments etc. complete as required. As per specification/drawings and as directed by PMC/Employer.

-

-

-

... More
2CX 1.5 Sq.mm

100

-

-

... More
CRC CABLE - Supply and laying, testing & commissioning of following sizes of Copper conductor control cables through PVC conduit on existing tray including fixing clamps & proper connections to equipments etc. complete as required for Central Remote Controller.

-

-

-

... More
2CX 1.5 Sq.mm

100

-

-

... More
Supply, Installation, testing & Commissioning PC compatible Centralised Remote Controller (CRC) for the Entire Indoor and Outdoor Equipment Configuration for Above systems. CRC shall be compatible on BACnet / Modbus BMS protocol. As per specification/drawings and as directed by PMC/Employer.

1

-

-

... More
DRAIN PUMPS

-

-

-

... More
Supply, Installation, Testing & Commissioning of Condensate Drain Pumps (1W + 1S) with Tank along with Level sensor. The pump should be interlocked with the sensor to avoid dry run. The pump should be with an Inbuilt non-return valves on discharge & solenoid valves as required. The tank capacity should be minimum 2 Litres in Capacity. The pump should be able to deliver 6m Vertical head @ 150 litres/ hr flow rate. The Power supply shall be single phase 230 V AC. Single phase power shall be provided near-by the pump. The necessary UPVC / CPVC Piping & Cabling Connection shall be done by contractor and the cost for the same to be considered (5m Cabling to be Included). Application - PAC Units for Computer & Server Rooms

3

-

-

... More
MINI DRAIN PUMPS

-

-

-

... More
Supply, Installation, Testing & Commissioning of Condensate Drain Pumps with Tank along with Level sensor. The pump should be interlocked with the sensor to avoid dry run. The pump should be with an Inbuilt non-return valves on discharge & solenoid valves as required. The tank capacity should be minimum 1 Litres in Capacity. The pump should be able to deliver 6m Vertical head.The Power supply shall be single phase 230 V AC. Single phase power shall be provided near-by the pump. The necessary UPVC / CPVC Piping & Cabling Connection shall be done by contractor and the cost for the same to be considered (5m Cabling to be Included). Application - Cassette Units . FCUs.

20

-

-

... More
PRECISION AIR CONDITIONERS

-

-

-

... More
a) Supply, Installation, testing and commissioning of Floor Mounted, PAC units for high density application, equiped with most advanced industry technology to operate at higher return air temperatures , guaranteeing precise control of temperature and relative humidity #Note: 1) Supplier shall submit computerised unit selection output. Installation also include Lifting, shifting, assemblling & positioning of the equipment comprising of the following and complete as per specification/drawings and as directed by PMC/Employer.and shall be complete

-

-

-

... More
b),. The units shall be selected on the basis of following parameters - 45°F / 55°F of chilled water temperature - Each unit shall be provided with PRESSURE INDEPENDENT BALANCING CUM CONTROL VALVE as per Specifications The intended design shall be to achieve the highest reliability of the system at lowest possible PUE

-

-

-

... More
c). The unit shall comprise of Fibreglass corrossion resistant EC fans, Evaporator cooling Coils, Microprocessor controllers, G4 Filter, Internal power and Control wiring, Heaters, Power and Control contactors, water leak detectors and other Electrical accessories.

-

-

-

... More
d). The Indoor unit shall comprise of Composite Material / Fibreglass corrossion resistant EC fans, Evaporator cooling Coil , Microprocessor controllers, 95% down to 5 micron filters, Internal power and Control wiring, Heaters, Power and Control contactors and other Electrical accessories. The Unit shall be selected at an External Static Pressure of 10mm of H2O.

-

-

-

... More
e). The control algorithm shall be for traditional return air logic and also be developed for containment applications, that meets the cooling and airflow needs of the servers while ensuring only necessary kilowatts are invested in targeted cooling. The unit should have the capability to modulate airflow, taking inputs from the remote sensors placed in cold aisle at top of the racks at multiple locations, according to the airflow taken by the servers. The control shall be done in order to have minimum differential pressure between inlet and outlet of the containment. The capacity shall be modulated according to the supply temperature in order to optimize server inlet temperature. The system done by multiple units shall work with efficient cascade way, trying to maximise energy efficiency always working where EC Fans are more effective.

-

-

-

... More
f). The unit shall be suitable for operation on 415 Volts, 50 Hz, 3 Phase, 4 Wire AC supply. Each unit should be having individual display panel, which shall display date, time, actual & set values, operating conditions, signal faults, collective faults, limiting values and PAC wellness alarm / service alarm to reduce the down time and unit memory shall hold the 400 most recent events with ID number, time and date stamp for each event.

-

-

-

... More
g). Operation & Control Features - P / PI / PID - All three Control logics for temperature control - Relative / Compensated / Predicttive method for humidity control - Temperature & Humidity graphs for the system (Avg. value of all the connected units) & for each single unit - Record of Peak & Low temperature/humidity of the current day - Choice of display: Graphical / Simple / Graphical Comma / Simple Comma - Display shows SET / ACTUAL / SET+ACTUAL Values - Records total run hours for all main components - Team Mode operation for synchronising upto 16 units in room by any of the unit controller

-

-

-

... More
- Sequencing & Stand-by rotation - Cascading, Lead-Lag functions - 16 days record of controlled parameters - Unit memory shall hold 200 recent alarms with date and time for each alarm - Unit memory shall hold 200 recent alarms with date and time for each alarm - Status report of last 400 event logs - 3 types of access; User, Service & Advanced to protect all settings - Auto restart after a power failure - Graphical display of status of operation of all major components like Fan, Heater & Humidifier on screen in an idle mode - Contains key contact info for local service including names and phone numbers - 254 types of Alarms / Warnings. - Monitoring card should be able to support any one of the protocol (Bacnet/Modbus/SNMP) - Each unit Controller should be capable of controller, monitoring, sharing set points and alarms upto 32 units. - Each Unit controller should have feature of avoiding fighting of operation modes for multiple units thus saving upto 15% power at larger sites - Onboard unit diary provides maintenance history

-

-

-

... More
h). Team Mode feature for PAC units controller for synchronising the Multiple No. of units to work as single system for different room as per Layout - Load sharing mode feature - Cascading Effect - Sequencing of Below Units

-

-

-

... More
The Cost of Necessary Indoor Stands, Vibration Isolators, (450mm False Floor Height), Motorized Dampers on top of the units, Flanges for Chilled Water connections shall be included in the quoted price.

-

-

-

... More
IBMS Server Room – 6000 CFM. Net Sensible Capacity 10.0 TR – 24 deg C On Coil Temperature – Bottom / Front Throw

2

-

-

... More
UPS Room – 4200 CFM. Net Sensible Capacity 7.0 TR – 24 deg C On Coil Temperature – Bottom / Front Throw

2

-

-

... More
VENTILATION WORKS

-

-

-

... More
Tube Axial Flow Fan for Smoke & Pressurization

-

-

-

... More
a). Supply, Installation, testing & Commissioning of Smoke Evacuation Tube Axial fan for Room Smoke exhaust complete with MS channel base, housing, fire retardant flexible connection with nut bolts at outlet, mounting, vibration isolators, & bird screen,wherever required for complete installation include Lifting, shifting, assemblling & positioning of the equipment comprising of the following and complete as per specification/drawings and as directed by PMC/EMployer

-

-

-

... More
b). Fan shall be provided with TEFC Sq.cage, direct driven 'H' Class induction motor for exhaust application & 'F' Class Induction motor for fresh air application with minimum IE-4 rating having Fire Rating for 250ºC for 2 hrs & suitable for 415V±10%, 50 Hz. 3 phase electric supply. The motor and impeller speed shall be as per specification and capacities shall be as follows The Fan must be selected for minimum power consuption & Maximum efficiancy at respective duty point .& min fan efficiency should be 70%.Fan power should not exceed 0.0006 BHP / CFM. However; If OEM is not able to meet 70% efficiency for any specific case, 65-70% fan efficiency can be excepted subject to detail technical justifications from Vendor/OEM." Max. noise level shall be 85 dBA at 3 meter in hemispherical reverberant room condition.

-

-

-

... More
c). The complete fan assembly shall be CE Certified in accordance with EN-12101-2:2015 or UL Listed conforming to UL-705 Power Ventilator for smoke exhaust OR TUV SUD PSB Pte Ltd(Vendor shall submit the certifications for below listed fans) Fan casing shall be de-rusted, cleaned, primed and finish coated with enamel paint or shall be hot dip galvanized with min. 220 GSM coating. Fan casing, motor mount support brackets for ceiling suspension shall be welded or bolted to the casing for connection to hanger bolts. Hub and Blades of Axial fans Impeller/Rotor shall be constructed for cast aluminium or aluminium alloy. Extended grease leads for external lubrication shall be provided for motors above 180 frame size. The fan pitch control maybe manually readjust able at site or at manufacturer’s facility. The motor and impeller speed shall be as per specification and capacities shall be as follows. Fan & motor shall be suitable for outdoor application. Necessary spring isolators for mounting of fan shall be considered in the cost.

-

-

-

... More
d). Fan Static Indicated below are tentative , Contractor shall submit Fan static calculations based on approved shop drawings before ordering the unit. Any rise in static required shall be offer by contractor without any additional cost. Note- "The Variation in Static Pressure Rise more than 20% will only be consider for Extra item, If there is change in layout w.r.t Tender drawing."

-

-

-

... More
50000 CFM, 25mm ESP - Smoke Extraction - Main Lobby & DG Room

7

-

-

... More
7500 CFM, 25mm ESP - Smoke Extraction - Multipurpose Hall

1

-

-

... More
8500 CFM, 25mm ESP - Smoke Extraction - Lobby

1

-

-

... More
17000 CFM, 25mm ESP - Fresh Air - Multipurpose Hall

1

-

-

... More
25500 CFM, 25mm ESP - Stairwell Pressurization

3

-

-

... More
32000 CFM, 25mm ESP - Fireman Lift Lobby Pressurization

2

-

-

... More
16000 CFM, 25mm ESP - Main Lift Lobby Pressurization

4

-

-

... More
26500 CFM, 25mm ESP - Lift Well Pressurization

11

-

-

... More
44500 CFM, 25mm ESP - STP Exhaust

1

-

-

... More
37200 CFM, 25mm ESP - STP Fresh

1

-

-

... More
22500 CFM, 25mm ESP - PHE Fire & Pump Room Fresh Air

1

-

-

... More
22500 CFM, 25mm ESP - PHE Fire & Pump Room Exhuast

1

-

-

... More
5500 CFM, 25mm ESP - OWC Exhaust

1

-

-

... More
Ducted Axial Flow Fan

-

-

-

... More
a). Supply, Installation, testing & Commissioning of Tube Axial fan for Room exhaust sutiable for Ducting along with Sound Attenuators to achieve noise levels as mentioned complete with MS channel base, housing, fire retardant flexible connection with nut bolts at outlet, mounting, vibration isolators, & bird screen,wherever required for complete installation include Lifting, shifting, assemblling & positioning of the equipment comprising of the following and complete as per specification/drawings and as directed by PMC/EMployer

-

-

-

... More
b). Fan shall be provided with TEFC Sq.cage, direct driven 'H' Class induction motor for exhaust application & 'F' Class Induction motor for fresh air application with minimum IE-4 rating having Fire Rating for 250ºC for 2 hrs & suitable for 415V±10%, 50 Hz. 3 phase electric supply. The motor and impeller speed shall be as per specification and capacities shall be as follows The Fan must be selected for minimum power consuption & Maximum efficiancy at respective duty point .& min fan efficiency should be 70%.Fan power should not exceed 0.0006 BHP / CFM. However; If OEM is not able to meet 70% efficiency for any specific case, 65-70% fan efficiency can be excepted subject to detail technical justifications from Vendor/OEM." Max. noise level shall be 85 dBA at 3 meter in hemispherical reverberant room condition.

-

-

-

... More
c). The complete fan assembly shall be CE Certified in accordance with EN-12101-2:2015 or UL Listed conforming to UL-705 Power Ventilator for smoke exhaust OR TUV SUD PSB Pte Ltd(Vendor shall submit the certifications for below listed fans) Fan casing shall be de-rusted, cleaned, primed and finish coated with enamel paint or shall be hot dip galvanized with min. 220 GSM coating. Fan casing, motor mount support brackets for ceiling suspension shall be welded or bolted to the casing for connection to hanger bolts. Hub and Blades of Axial fans Impeller/Rotor shall be constructed for cast aluminium or aluminium alloy. Extended grease leads for external lubrication shall be provided for motors above 180 frame size. The fan pitch control maybe manually readjust able at site or at manufacturer’s facility. The motor and impeller speed shall be as per specification and capacities shall be as follows. Fan & motor shall be suitable for outdoor application. Necessary spring isolators for mounting of fan shall be considered in the cost.

-

-

-

... More
d). Fan Static Indicated below are tentative , Contractor shall submit Fan static calculations based on approved shop drawings before ordering the unit. Any rise in static required shall be offer by contractor without any additional cost. Note- "The Variation in Static Pressure Rise more than 20% will only be consider for Extra item, If there is change in layout w.r.t Tender drawing."

-

-

-

... More
22,500 CFM, 20mm ESP, Noise level of the fan should be less than 65dba @3M distance- LT Panel Room Exhaust (With attenuator)

1

-

-

... More
19,000 CFM, 20mm ESP, Noise level of the fan should be less than 65dba @3M distance- LT Panel Room Supply (With attenuator)

1

-

-

... More
12,500 CFM, 20mm ESP, Noise level of the fan should be less than 65dba @3M distance- Plant Room Exhaust (With attenuator)

2

-

-

... More
21,500 CFM, 20mm ESP, Noise level of the fan should be less than 65dba @3M distance- Transformer Room Exhaust (With attenuator)

1

-

-

... More
18,000 CFM, 20mm ESP, Noise level of the fan should be less than 65dba @3M distance- Transformer Room Supply (With attenuator)

1

-

-

... More
Cabinet Fans

-

-

-

... More
Supply, Installation, Testing and Commissioning of Double skin cabinet type, inner skin and outer skin shall be minimum 1 mm thick pre-coated and pre plasticized sheets, Puff panel of 25 mm(+/-1mm) thickness, density of insulation shall be 48 Kg/sq.m, DIDW/SISW backward curve fan with motor shall be IE 4 type fan motor to suitable for VFD to rampup & ramp down the motor speed, (VFD in seperate line item) Fan total efficiency shall be minimum 75%,Fan power should not exceed 0.0006 BHP / CFM, unit base with suitable size of coushy foot mounting, Motor winding shall be vacuum pressure impregnated for all motors. Insulated bearing on non-drive end for Motor frame of 315 and above shall be provided. fans are rated and tested in accordance with AMCA standard to meet the air and sound performance requirements, Selected Motor rating shall be minimum 15% above BKW.. Cost inculde at site perfromance test with OEM Engineer. Weather proof canopy should be provided for all units located on terrace. An extended canopy of 150 mm all around the unit to be considered.

-

-

-

... More
Fan Static Indicated below are tentative , Contractor shall submit Fan static calculations based on approved shop drawings before ordering the unit. Any rise in static required shall be offer by contractor without any additional cost. Note- "The Variation in Static Pressure Rise more than 20% will only be consider for Extra item, If there is change in layout w.r.t Tender drawing."

-

-

-

... More
3750 CFM, 40mm ESP - Electrical Room Exhaust

2

-

-

... More
1200 CFM, 40mm ESP - Toilet Exhaust

2

-

-

... More
DUCT MOUNTED RECTANGULAR IN LINE FAN UNIT:

-

-

-

... More
a). Supply, Installation, testing & Commissioning of following capacities of ducted inline fan with AMCA certified (AMCA certification requird for Air Performance & Sound) as per specification and complete with suitable 1 phase Motor with 3 speed control,bird screen. etc. and required for complete installation include Lifting, shifting, assemblling & positioning of the equipment comprising of the following and complete as per specification/drawings and as directed by PMC/Employer. The Fan must be selected for minimum power consuption & Maximum efficiancy at respective duty point. The fan casing shall be made of galvanised steel casing with min. 200 GSM zinc coating. Max. noise level shall be 78 dBA at 3.0 meter.Fan power should not exceed 0.0006 BHP / CFM.

-

-

-

... More
b). Fan Static Indicated below are tentative , Contractor shall submit Fan static calculations based on approved shop drawings before ordering the unit. Any rise in static required shall be offer by contractor without any additional cost. Note- "The Variation in Static Pressure Rise more than 20% will only be consider for Extra item, If there is change in layout w.r.t Tender drawing."

-

-

-

... More
c. The cost of the Inline Fan also includes DOL Starter with On/off push button staton, A/M Status and PF/relays etc for BMs integration and along with inbuilt fan regulator.

-

-

-

... More
d. All Inline fan shall be provided with all necessary supports. Unit shall be provided along with fire retardant flexible canvass with Zip, Cowl piece with bird mesh and supporting arrangements.

-

-

-

... More
2400 CFM, 25mm ESP - Toilet Ground Floor Exhaust

1

-

-

... More
500 CFM, 25mm ESP - Toilet Exhaust

1

-

-

... More
250 CFM, 25mm ESP - Toilet Exhaust

1

-

-

... More
KITCHEN FAN SISW FAN

-

-

-

... More
a). Supply, Installation, testing & Commissioning of Fan - SISW backward curved centrifugal fan with necessory supports arrangement, sq cage induction motor, GSS frame support work, belt drive with required size pullys and belts, spring type vibratioin isolator, base frame along complete installation include Lifting, shifting, assemblling & positioning of the equipment comprising of the following and complete as per specification/drawings and as directed by PMC/Employer

-

-

-

... More
b).Fan Scroll shall be galvanised with min. 220 gsm Galvanised zinc coating with non stick paint. Complete fan, blade shall be powder coated with non stick paint. Fan must be with side discharge & provided with spring type vibration isolators, cowl piece, etc Entire fan assembly shall be suitable for Kitchen exhaust application. Motor shall be outside the airstream -Class F Type Exhaust fans shall be with insect mesh at to exhaust air & belt gaurd. Fan performance rating data shall be tested accordance with AMCA Standard 210-85 (AMCA certification requird for Air Performance & Sound). The Fan must be selected for minimum power consuption & Maximum efficiancy at respective duty point.

-

-

-

... More
c). Fan motor shall be class IE4 and suitable to 415+/-10% V, 50 hz, 3 phase AC supply. Fan shall be suitable for Kitchen exhaust. Fan total efficiency shall not be less than 70%. However; If OEM is not able to meet 70% efficiency for any specific case, 65-70% fan efficiency can be accepted subject to detail technical justifications from Vendor/OEM." Max. noise level shall be 75 dBA at 3 meter in hemispherical reverberant room condition.Fan power should not exceed 0.0006 BHP / CFM.

-

-

-

... More
d). Fan Static Indicated below are tentative , Contractor shall submit Fan static calculations based on approved shop drawings before ordering the unit. Any rise in static required shall be offer by contractor without any additional cost. Note- "The Variation in Static Pressure Rise more than 20% will only be consider for Extra item, If there is change in layout w.r.t Tender drawing."

-

-

-

... More
38000 CFM @ 45 mm ESP

1

-

-

... More
Kitchen Dry Scrubber

-

-

-

... More
a). Supply, Installation, testing & Commissioning of industrial grade electrostatic air cleaner , complete as per technical specifications with all the necessary mounting accessories as required for complete installation.Dry scrubber – Electrostatic Air cleaner as per specifications, suitable for following capacities. The Air filtration efficiency should be 90% & units shall be offered singular/ multiple module as per OEM to staked one above other or side by side as per site requirement. Finishing - Power coated, Features - Short circuit, arc protection with auto power restore for power pack. As per specification/drawings and as directed by PMC/Employer. No. of ESP cells to be selected from manufacturer's standard range to meet total exhaust CFM.

-

-

-

... More
b). Operating voltage - 220 VAC+/-10%, 50 Hz (Single phase) Cell - Ionizing voltage - 12 KVdc Collector voltage - 6 KVdc One cell comprising of 9 ionizing wires and 25 collection plates Controls - Auto cut-off when door is opened. Indicator lights for fault, normal or wash function. Pre-filter - Aluminium mesh, washable Dry contact for BMS. Unit must be of Autowash type.

-

-

-

... More
38000 CFM

1

-

-

... More
TWO STAGE EVAPORATIVE COOLING SYSTEM - Blow Through

-

-

-

... More
Two stage evaporative cooling system shall comprise of Indirect and Direct cooling heat exchangers. Indirect heat exchanger shall be of Engineered Polymer with thermally fused non woven media. Direct heat exchanger shall be made up of cellulose impregmented paper (min 300mm deep) or equivalent material. Air velocity acoss heat exchangers shall be between 2-2.5 m/s. UL performance validation chart to be provided for Indirect heat exchanger.

-

-

-

... More
Unit shall be of 23 ± 1 mm thick CFC free PUF Insulation to density of 38-42Kg/m3. Skin shall be 0.63 mm inner and outer pre-coated GI. Structure shall be of hollow aluminium profile with nylon connectors. Base frame shall be of GI 1.6mm thick with Die cast Al. connectors.Entire unit shall be suitable for Outdoor application.

-

-

-

... More
2 stage filtration using MERV 8 & MERV 13 filters.

-

-

-

... More
Sump shall be of SS 304 material.

-

-

-

... More
Pumps shall be Submersible type.

-

-

-

... More
UV lamp unit shall be provided in machine to treat the sump water.

-

-

-

... More
Fan shall be Blow Through type

-

-

-

... More
Primary fan shall be DIDW centrifugal backward curved with VFD.

-

-

-

... More
Marine lamp, Limit switch, door protection to be provided.

-

-

-

... More
Units shall have precoated GI canopy and GI louvers before filters as a part of the unit

-

-

-

... More
Manufacturer need to provide performance curve for Indirect heat exchanger type- tested and validated by UL.

-

-

-

... More
Canopy to be provided for all Outdoor Unit.

-

-

-

... More
Capacity - 30500 CFM @ 40 mm ESP

1

-

-

... More
Electrical starter & control panel for Two Stage Evaporative Cooling System - Supplied by machine manufacturer

-

-

-

... More
Panel shall be inline with IP65 with double door suitable for outdoor installation. PLC based to run the machine, with necessary temperature and RH sensors display, control setting for Temp. & RH, main incomer SFU/MCCB, protections, etc. All internal wiring shall be neat and proper. Panel shall be part of machine supply. Necessary sensors for showing parameters to be considered.

-

-

-

... More
Manufacturer must consider all cable requirements from Panel to motor,Pumps,UV Lamp,Marine Lamp,Limit Switch.Also earting for Panel to be considered

1

-

-

... More
Chemical Passivation of System as per below requirement for below Mentioned Chilled Water Piping Quantity. All Pipes need to be flushed before initiaion of Chemical Flushing. Water quality tests before and intermediate between adding of chemicals to be done and report to be generated. Necessary auto dosing system PLC based with TDS Analyser, pH Sensor etc. to be considered. for automatic working of the system. Contractor to submit the chemical weight calculations, standard operating procedures and operations manual before initiations of work. 1 Yeat weight of chemicals to be considered in the cost

1

-

-

... More
Pre-Cleaning & Passivation with chemicals

-

-

-

... More
Surfactant cleaning

-

-

-

... More
Bioflushing

-

-

-

... More
Low pH cleaning

-

-

-

... More
Passivation Chemical

-

-

-

... More
Supply, Installation, Testing and Commissioning of duct mounted Ozone generator with all accessories required to make the system complete .The Ozone generation system shall be provided for STP. Ozone generator shall include necessary electrical power socket with power and Control wiring, necessary sensors and controllers required for BMS interfacing. As per specification/drawings and as directed by PMC/Employer. The ozone generation system shall be provided with Automatic safety interlock for O3 Concentration more than 0.1 PPM as per OSHA Application- The Ozone generators are provided to mitigate the foul smell of STP Exhaust.

-

-

-

... More
44500 CFM

1

-

-

... More
INSULATED CHILLED WATER PIPE AND VALVES FOR CHILLED WATER PIPES (PLANT ROOM & OUTDOOR PIPES)

-

-

-

... More
Supply, erection, testing and commissioning for Chilled water circulation pipes. Pipes will be of Mild Steel (pipe wall thickness as indicated below) and insulation material shall be with Closed Cell Nitrile Rubber as per the specification. MS 'C' class pipes as per IS 1239 / IS 3589 with specified wall thickness cut to required lengths and installed with all Accessories All pipes shall be with 26 G Aluminium Cladding All Pipes shall be Sandblasted before Insulation Class of Pipe:- Sizes up to 150 mm shall confirm to IS 1239 Sizes above 150 mm shall confirm to IS 3589 MS 'C' class pipes up to 150 mm dia The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia. All GI / MS supports along with accessories for a maximum height of 2-3 mtr either from the ceiling slab or floor slab shall be considered in this item. All pipes shall be with 26 G Aluminium Cladding

-

-

-

... More
350 mm dia.(64 mm thick insulation)

219

-

-

... More
300 mm dia (64 mm thick insulation)

6

-

-

... More
250 mm dia (64 mm thick insulation)

54

-

-

... More
200 mm dia (64 mm thick insulation)

180

-

-

... More
150 mm dia (64 mm thick insulation)

50

-

-

... More
125 mm dia (57 mm thick insulation)

513

-

-

... More
100 mm dia (57 mm thick insulation)

12

-

-

... More
80 mm dia (51 mm thick insulation)

256

-

-

... More
INSULATED CHILLED WATER PIPE AND VALVES FOR CHILLED WATER PIPES (RISERS & CONNECTIONS) Supply, erection, testing and commissioning for Chilled water circulation pipes. Pipes will be of Mild Steel (pipe wall thickness as indicated below) and insulation material shall be with Closed Cell Nitrile Rubber with Al Foil / Glass Cloth as per the specification. MS 'C' class pipes as per IS 1239 / IS 3589 with specified wall thickness cut to required lengths and installed with all Accessories Class of Pipe:- Sizes up to 150 mm shall confirm to IS 1239 Sizes above 150 mm shall confirm to IS 3589 MS 'C' class pipes up to 150 mm dia The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia. All GI / MS supports along with accessories for a maximum height of 2-3 mtr either from the ceiling slab or floor slab shall be considered in this item.

-

-

-

... More
250 mm dia (45 mm thick insulation)

60

-

-

... More
200 mm dia (41 mm thick insulation)

536

-

-

... More
150 mm dia (41 mm thick insulation)

387

-

-

... More
125 mm dia (41 mm thick insulation)

444

-

-

... More
100 mm dia (32 mm thick insulation)

640

-

-

... More
80 mm dia (32 mm thick insulation)

974

-

-

... More
65 mm dia (25 mm thick insulation)

1708

-

-

... More
50 mm dia (25 mm thick insulation)

896

-

-

... More
40 mm dia (19 mm thick insulation)

882

-

-

... More
32 mm dia (19 mm thick insulation)

866

-

-

... More
25 mm dia (19 mm thick insulation)

250

-

-

... More
Supply and erection of Insulated PN-16 Manual Butterfly valves with C I body SS Disc, Nitrile Rubber Seal & O- Ring (as per specifications) complete with pre-insulated end flanges / matching flanges, additional supports, fixing accessories, etc. The valve shall be gear operated for 200NB and above. Insulation shall be as per piping insulation specification.

-

-

-

... More
350 mm dia

3

-

-

... More
300 mm dia

2

-

-

... More
250 mm dia

2

-

-

... More
200 mm dia

30

-

-

... More
150 mm dia

5

-

-

... More
125 mm dia

53

-

-

... More
100 mm dia

5

-

-

... More
80 mm dia

13

-

-

... More
65 mm dia

100

-

-

... More
50 mm dia

256

-

-

... More
Supply and erection of Insulated PN-16 Dual plate Check valves of C I body SS plates vulcanized NBR seal flanged end complete with pre-insulated end flanges/matching flanges, additional supports, fixing accessories, etc.

-

-

-

... More
250 mm dia

1

-

-

... More
200 mm dia

8

-

-

... More
125 mm dia

8

-

-

... More
Supply, Installing, testing and commissioning of PN 16 rating Flexible Pipe Connections (Expansion bellows) with connecting rod & Nitrile rubber insulated covered with 24G aluminium sheet box, in position complete with flanges,bolts,nuts, including gaskets etc.conforming to specifications. As per specification/drawings and as directed by PMC/Employer.

-

-

-

... More
200 mm dia

24

-

-

... More
125 mm dia

24

-

-

... More
Design, Supply, installation, testing and commissioning of Insulated PN-16 Balancing Valve with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation. It shall be of factory calibrated direct, acting, automatic pressure compensation type. Each valve shall limit flow rates to within ± 5 % accuracy, regardless of the system pressure fluctuations. Rate shall inclusive of additional supports, fixing accessories, thermal insulation, etc.

-

-

-

... More
250 mm dia

1

-

-

... More
200 mm dia

8

-

-

... More
150 mm dia

1

-

-

... More
125 mm dia

5

-

-

... More
100 mm dia

1

-

-

... More
80 mm dia

4

-

-

... More
65 mm dia

1

-

-

... More
50 mm dia

1

-

-

... More
40 mm dia

1

-

-

... More
Supply and erection of Insulated PN-16 ‘Y’ type strainer of Ductile CI Body flanged ends with stainless steel strainer with removable stainless steel screen with 3mm perforation and permanent magnet, drain piping. Rate shall inclusive of pre-insulated end flanges/matching flanges, additional supports, fixing accessories, etc.

-

-

-

... More
125 mm dia

4

-

-

... More
100 mm dia

1

-

-

... More
80 mm dia

1

-

-

... More
65 mm dia

20

-

-

... More
50 mm dia

90

-

-

... More
40 mm dia

18

-

-

... More
32 mm dia

1

-

-

... More
25 mm dia

1

-

-

... More
Design, Supply, installation, testing and commissioning of Insulated PN-16 Motorized Valves (ON / OFF Type) with thermal insulation provided with spring return function in chilled water lines at chillers and condenser water line at cooling towers. Supplying, fixing, testing and commissioning of following sizes Motorized Butter fly Valve with CI Body, SS Disc,O - ring and minimum PN-16 pressure rating , conforming to BS 5155, IS 13095, with IP-55 actuator, capable of accepting upto 10V DC , and upto 20mA electric signal and providing similar transduced feedback output to control system as required. The Actuator shall be supplied along with its Actuator panel.

-

-

-

... More
250 mm dia

1

-

-

... More
200 mm dia

4

-

-

... More
125 mm dia

2

-

-

... More
100 mm dia

1

-

-

... More
Design, Supply, Installation, testing and commissioning of Insulated Flow Control Valve - Pressure independent type with Dynamic Balancing Cum 2 Way modulating valves with Thermal Insulation for AHUs with actuator in a single Unit of Valve provided with spring return function. The valve shall be suitable for standalone operation. Valve shall be of PN16 Rating. The BMS compatible actuator shall be supplied by the valve manufacturer and capable of accepting 2-10VDC / 4- 20 mA electric signal and shall provide similar transduced feedback output signal to control system. The minimum close off Pressure of actuator must be 1.5 times shut off head of pump as per specifications. Rate shall be inclusive of stepdown transformer, digital thermostat (modulation type) suitable for the given actuator, required length of 2Cx1.5Sqmm shielded communication cable, end flanges/matching flanges, additional supports, fixing accessories, dismantling the existing valves, thermal insulation, etc The Actuator shall be supplied along with its Actuator panel.

-

-

-

... More
150 mm dia

1

-

-

... More
125 mm dia

4

-

-

... More
100 mm dia

1

-

-

... More
80 mm dia

1

-

-

... More
65 mm dia

20

-

-

... More
50 mm dia

51

-

-

... More
40 mm dia

19

-

-

... More
32 mm dia

18

-

-

... More
BTU METER

-

-

-

... More
Supply, installation, testing and commissioning of BTU Meter - to measure the HVAC Consumption Purpose. The Unit shall include an Heat Meter Integrator, Ultrasonic type Flow meter, matched pair of Temperature Sensors (along with the protection pockets). The Integrator shall have Battery backup for 12 years, Data Logging for 15 years, 230V AC power supply provision, 8 Digit LCD Display The Unit should be capable of displaying the CHW Flow Rate, BTU / Hr, KWH, CHW Temperature. The Unit shall be with IP55 grade of protection (Maximum Pressure drop across BTU meter 0.2 WC) The BTU Meter shall be MID approved In-Line Flange Connection type. The Integrators shall be capable of communicating on a communication bus to the BMS on one of Standard Open Protocols such as MODBUS / Bacnet over IP etc. BTU Meters shall be tested for performance and accuracy before delivery.

-

-

-

... More
a) Inline Flow Meter, b) Match Pair Sensors c) Heat Integrator d) Minimum 4 Data / Meter to Master Contoroller - T1 / T2 / Flow / KWH - with 2 mtr 2C shielded communication cable

-

-

-

... More
Btu Transmitters as per the specification for tenant billing. Btu Meters shall consist of following items of following sizes:-

-

-

-

... More
350 mm dia

1

-

-

... More
125 mm dia

1

-

-

... More
100 mm dia

1

-

-

... More
65 mm dia

20

-

-

... More
50 mm dia

39

-

-

... More
32 mm dia

20

-

-

... More
25 mm dia

39

-

-

... More
Supply and erection of PN-16 pressure rating extended stem ball valve, bronze forged body, Stainless Steel ball and control level etc. in position complete as per technical specifications with all the necessary mounting accessories, end flanges / matching flanges, additional supports, fixing accessories, thermal insulation, etc.as required for complete installation as per specification.

-

-

-

... More
40 mm dia

90

-

-

... More
32 mm dia

34

-

-

... More
25 mm dia

170

-

-

... More
Supply, installation testing & commissioning of Bourdan Tube Pressure Guages (ALL SS TYPE) Pressure guages shall be of Bourdon (150 mm) type with range selected so that normal operation is near to middle of the scale. Syphons and cocks to be provided along with SS snubber.

236

-

-

... More
Supply, installation testing & commissioning of Thermometers - Dial Type - 4" Dia (ALL SS TYPE) Thermometers of approved make & shall be of mercury in steel type with range suitable for the temperature services. It should be installed in the thermowells as explained in the tender specifications. Extension nipple shall be provided for a minimum depth of 150 mm.

220

-

-

... More
Supply, installation testing & commissioning of Automatic Air Vents with Ball valve shall be installed at all high sections of piping as well as in the AHU room piping. The discharge from this air vents shall be piped via copper tubes of appropriate size to the nearest waste drain pipe.

-

-

-

... More
15 mm dia. With 15mm ball valve

21

-

-

... More
EXPANSION TANK & PRESSURISING UNIT

-

-

-

... More
a). Expansion Tank- Supply, Installing, Testing and commissioning of the following capacities Closed Expansion tank with full acceptance Factor and shall be ASME rated/ European standard code no. 97/23/EC/ IS Standards, pre-charged bladder-type pressure vessels. The tank shall be designed to absorb the expansion forces of heating/cooling system water while maintaining proper system pressurization under varying operating conditions. The heavy duty bladder should contain system water thereby eliminating tank corrosion and water logging problems. The system should include PRV and Airvent also. And complete as per technical specification. Tank shall be selected for PN-16 rating . The tank shall duly insulated with closed cell elastometric nitrile rubber as per specifications.

-

-

-

... More
b). Supply, Installing, Testing and commissioning of Pressurizing unit consisting of Inline vertical multistage, centrifugal clear water pumps ( 1W+1S) with S.S. 304 casing, S.S. 304 impeller and S.S. 316 shaft, CI Base,TEFC motor (with mechanical seal) with control panel with duty cycling and dry run protection and set of accessories such as pressure transmitter, suction and discharge pipe manifolds, pressure gauges, valves etc. conforming to the specifications. The make up tank location should be at least 1 meter above the pump level. As per specification/drawings and as directed by PMC/Employer.

-

-

-

... More
c). Contractor shall calculated total system water quantity and total system head acting on the expansion tank and based on this select expansion tank capacity.

-

-

-

... More
2000 litres

1

-

-

... More
500 litres

1

-

-

... More
AIR SEPARATOR

-

-

-

... More
a).Supply, Installing, Testing and commissioning of centrifugal/ coalescence / microbubble type air separator with pall rings for following pipe size. The unit shall have an internal stainless steel collector tube with 5/32” (4mm) diameter perforations and 63% open area designed to direct accumulated air to the compression tank on an air control system or an air vent on an air elimination via an NPT vent connection at top of the unit. As per specification/drawings and as directed by PMC/Employer.

-

-

-

... More
b). Air separator shall duly insulated with closed cell elastometric nitrile rubber as per Header Piping Specifications

-

-

-

... More
350 dia - PN 16

1

-

-

... More
125 dia - PN 16

1

-

-

... More
CONDENSER WATER PIPE AND VALVES

-

-

-

... More
Condenser Water Piping. Suppling, fixing testing & commissioning of condenser water pipes of following sizes of MS C' Class along with nececessary clamps, vibration isolators and fittings sich as bends, tees etc. but excluding valves, strainers, gauges etc, adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc, as per slecification and as required complete in all respect. Note: The pipes size 150mm & below shall be M.S C class as per IS : 1239 and pipe size above 150mm shall be welded black steel pipe heavy class as per IS : 3589, from minimum 6.35mm thick M.S. sheet for pipe upto 350mm dia. And from minimum 7mm thick MS sheet for pipes of 400mm dia and above.

-

-

-

... More
450 mm dia

361

-

-

... More
350 mm dia

12

-

-

... More
300 mm dia

6

-

-

... More
250 mm dia

288

-

-

... More
200 mm dia

108

-

-

... More
150 mm dia

24

-

-

... More
100 mm dia

124

-

-

... More
80 mm dia

6

-

-

... More
50 mm dia

80

-

-

... More
Supply fixing testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specification.

-

-

-

... More
BUTTERFLY VALVE Manual with C I body SS disc nitrile sheet % O - ring & PN 16 pressure rating complete with pre-insulated end flanges / matching flanges, additional supports, fixing accessories, etc

-

-

-

... More
450 mm dia

4

-

-

... More
250 mm dia

20

-

-

... More
200 mm dia

8

-

-

... More
150 mm dia

4

-

-

... More
100 mm dia

8

-

-

... More
80 mm dia

4

-

-

... More
50 mm dia

8

-

-

... More
Supply fixing testing and commissioning of Non Return Valve for condenser water circulation as per specification. Non-Return Valve with dual plate of C I body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating complete with end flanges/matching flanges, additional supports, fixing accessories, etc.as specified.

-

-

-

... More
250 mm dia

4

-

-

... More
Supply, Installing, testing and commissioning of PN 16 rating Flexible Pipe Connections (Expansion bellows) with connecting rod & Nitrile rubber insulated covered with 24G aluminium sheet box, in position complete with flanges,bolts,nuts, including gaskets etc.conforming to specifications. As per specification/drawings and as directed by PMC/Employer.

-

-

-

... More
250 mm dia

16

-

-

... More
Design, Supply, installation, testing and commissioning of PN-16 Balancing Valve with C I body flanged construction with EPDM coated disc shall be of factory calibrated direct, acting, automatic pressure compensation type. Each valve shall limit flow rates to within ± 5 % accuracy, regardless of the system pressure fluctuations. Rate shall inclusive of additional supports, fixing accessories, thermal insulation, etc.

-

-

-

... More
250 mm dia

4

-

-

... More
200 mm dia

8

-

-

... More
Supplying, fixing, testing and commissioning of following sizes Motorized butterfly valve with CI Body, SS Disc, O-ring and minimum PN-16 pressure rating, conforming to BS 5155, IS 13095, with IP-55 actuator, capable of accepting upto 10V DC, and upto 20mA electric signal and providing simillar transduced feedback output to control system as required. The Actuator shall be supplied along with its Actuator panel.

-

-

-

... More
250 mm dia

8

-

-

... More
200 mm dia

4

-

-

... More
Supply, installation testing & commissioning of Thermowells. Extension shall be provided for a minimum depth of 100 mm. There should be a minimum projection of 25 mm over and above insulated pipe.

28

-

-

... More
Supply, installation testing & commissioning of Binder type Test Points. Extension nipple shall be provided for a minimum depth of 100 mm. There should be a minimum projection of 25 mm over and above insulated pipe.

24

-

-

... More
Supply and installation of PN-16 Pot strainer of size suitable for 450NB pipeline to remove the dirt particles in the condenser water loop with necessary flanges, washers, painting, etc. complete as required. MS (IS 2062-1992 Gr A) body and bonnet with Stainless Steel 3 mm perforated x 24 G thick filter screen, black rubber gasket, heavy duty mild steel hand wheel & stainless steel-410 drain plug etc. Testing confirming to BS - 6755 Part-1.

2

-

-

... More
Providing, fixing and testing GI 'B' Class (Medium class) drain piping for condensate complete with 9 mm thick nitrile rubber insulation with class O, covered with interwoven glass fabric for UV and mechanical protection, all required fittings and providing clean out plug at suitable location for roding the pipe when required.As per technical specifications with all the necessary mounting accessories as required for complete installation. As per specification/drawings and as directed by PMC/Employer.

-

-

-

... More
50mm dia

120

-

-

... More
40mm dia

100

-

-

... More
Supply Insulated CPVC Condensate Drain piping as per specification as mentioned in the document insulated same as chilled water piping but without polyshield covering.Consider drip pans with drian pipe .Entire drain pipe needs to be insulated with 6mm thick closed cell Nitrile rubber.

-

-

-

... More
65 mm dia

50

-

-

... More
50 mm dia

65

-

-

... More
40 mm dia

35

-

-

... More
32 mm dia

75

-

-

... More
25 mm dia

134

-

-

... More
LOWDISE DUCTING WORKS

-

-

-

... More
SHEET METAL DUCTING

-

-

-

... More
Supply, installation balacing and commissoning of factroy fabricated GSS sheet metel rectangular/ round duct complete with neoprene rubber gaskets, elbows, spliter dampers, vanes, hangers suppots, etc. As per approved drawings and specifications of following sheet thickness complete as required.

-

-

-

... More
All ducts shall be fabricated either from Galvanised Sheet Steel (GSS) conforming to IS: 277 or aluminium sheets conforming to IS:737. The steel sheets shall be hot dip galvanized with MAT finish with coating of minimum 120 grams per square meter (GSM) of Zinc, GI sheets shall be lead free, eco friendly and RoHS compliant. The Duct with TDF Flanges shall be accepted as per SMACNA.

-

-

-

... More
Duct pressure test to be considered (0-500 Psi) with nessarry supporting materials part of this item (Vendor need to be submit detailed report before applying insulation.

-

-

-

... More
0 to 750 mm - 0.63 mm ( With Ductmate Flanges)

5500

-

-

... More
751 to 1500 mm 0.8 mm ( With Ductmate Flanges)

9100

-

-

... More
1501 to 1800 mm - 1.0 mm ( With Ductmate Flanges)

920

-

-

... More
1801 & Above - 1.2 mm (With Ductmate Flanges)

2000

-

-

... More
Supply, installation, balancing and commissioning of Flat Oval / Spiral Oval / Round Ducts (Shall be approved as per Architect) base complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.

-

-

-

... More
All ducts shall be fabricated either from Galvanised Sheet Steel (GSS) conforming to IS: 277 or aluminium sheets conforming to IS:737. The steel sheets shall be hot dip galvanized with MAT finish with coating of minimum 120 grams per square meter (GSM) of Zinc, GI sheets shall be lead free, eco friendly and RoHS compliant

-

-

-

... More
Note:- The Duct with shall be accepted with following: 1.For reinforcement of Duct shall be followed as per IS-655:2006 table number 23. 2.Ducts shall be tested as per specifications post installation. 3. Necesary steel wire rod supports / rigid supports for Installation to be considered 4. All ducts to be Insulated with 9mm Closed Cell Nitrile Rubber Insulation internally as per Tender Specifications

-

-

-

... More
Thickness 0.63 mm sheet- 0 to 650 mm

200

-

-

... More
Thickness 0.80 mm sheet - 651 to 1250 mm

150

-

-

... More
Thickness 1.00 mm sheet - 1251 to 2200 mm

150

-

-

... More
Thickness 1.25 mm sheet - 2201 & Above

80

-

-

... More
LOWDISE AIRTERMINAL WORKS

-

-

-

... More
AIR TERMINAL DEVICES

-

-

-

... More
Supplying, fixing testing commissioning of supply air square / plaque diffusers of powder coated aluminium as per approved shade with aluminium volume control dampers, necessary insulated plenum box with anti smudge ring & removable core. Colour: Approval shall be obtained from Interior consultant. As per specification/drawings and as directed by Architect & PMC/Employer. The Billing Area shall be based on Neck Size.

10

-

-

... More
Supplying, fixing testing commissioning of Return air square / plaque diffusers of powder coated aluminium as per approved shade without volume control dampers with anti smudge ring & removable core. Colour: Approval shall be obtained from Interior consultant. As per specification/drawings and as directed by Architect & PMC/Employer. The Billing Area shall be based on Neck Size.

15

-

-

... More
Supplying & fixing of powder coated extruded aluminium Supply Air Grills 1.6mm thickness as per standards as per approved shade with aluminium anodized opposed blade volume control dampers as per specifications. Note- Grill shall be provided with 0 deg / 15 deg or with double delfection type as per interior requirment. Colour: Approval shall be obtained from Interior consultant.

50

-

-

... More
Supplying & fixing of powder coated extruded aluminium Return Air Grills 1.6mm thickness as per standards as per approved shade without volume control dampers. Note- Grill shall be provided with 0 deg / 15 deg or with double delfection type as per interior requirment. Colour: Approval shall be obtained from Interior consultant.

100

-

-

... More
Supplying & fixing of powder coated extruded aluminium removable core type Supply Air Slot Diffusers (1 Slot / Multiple Slot as per Drawing) 1.6mm thickness as per standards as per approved shade with aluminium anodized opposed blade / hit & miss volume control dampers & inusulated plenum boxes as per specifications. Colour: Approval shall be obtained from Interior consultant.

180

-

-

... More
Supplying & fixing of powder coated extruded aluminium removable core type Return Air Slot Diffusers (1 Slot / Multiple Slot as per Drawing) 1.6mm thickness as per standards as per approved shade. Colour: Approval shall be obtained from Interior consultant.

230

-

-

... More
FLOOR GRILLE

-

-

-

... More
Supply & fixing of Extruded Aluminium powder coated Floor Grille as per approved shade along with Al powder coated in black finish collar damper . The supply air grill shall have provision to close or open damper manually from outside. The Grills shall be with minimum 65% opening and minium 1.5mm thick considering occupancy loading. Colour: Approval shall be obtained from Interior consultant. As per specification/drawings and as directed by Architect & PMC/Employer - 600 x 600 mm

20

-

-

... More
Supply, installation of Collar Dampers of opposed blade type made out of Aluminium alloy extrusion with anodised matt black finish.

100

-

-

... More
Supply, Installing, testing and comissioning of Powder coated extruded aluminium construction fresh air/ Exhaust air louvers with min. 60 % free area, bird screen as per specifications. Louvers need to be suitable in order to avoid rain water entry @ 45 degree deflection.As per technical specifications with all the necessary mounting accessories as required for complete installation. Colour: Approval shall be obtained from Interior consultant. As per specification/drawings and as directed by Architect & PMC/Employer

35

-

-

... More
Supply and installation of Powder coated extruded aluminium Disc Valve of the following diameter for exhaust air. The rate shall be inclusive of volume control damper and necessary fixing and supporting arrangement for the valve. Size:150mm Dia neck

720

-

-

... More
Supply, installation of JET NOZZLES of powder coated aluminium with volume control dampers & removable core for supply air distribution. Colour: Approval shall be obtained from Interior consultant.

-

-

-

... More
350 mm dia

48

-

-

... More
300 mm dia

12

-

-

... More
Supply, installation of Insulated Flexible Ducting Factory Fabricated Insulated with 32 kg/mr3 dense Glasswool Flexible ducts made out aluminium for connecting from main duct to diffuser box duly supported at regular interval as per site requirement etc. The length of the flexible duct shall be around 1.0 to 1.5 mtr.

-

-

-

... More
150 mm dia

20

-

-

... More
250 mm dia

25

-

-

... More
300 mm dia

20

-

-

... More
Supply installations of Butterfly Dampers made out of 20G GI sheets similar duct specifications.

-

-

-

... More
150mm dia

48

-

-

... More
200 mm dia

12

-

-

... More
250mm dia

36

-

-

... More
300mm dia

24

-

-

... More
Oppossed blade Low leakage Aluminium volume control damper with locking arrangement. VCD Construction18G GI in multi blade with handle and wing nut , clearly marked with open/close, for supply and return air duct branches. Low Leakage Volume Control Dampers of Class 1. VCD shall be complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications. (Extended shaft of minimum 150mm length with GI base plate shall be provided wherever required during drawing Approval). Volume Control damper may be without AMCA certification. However, OEM's Self Certification is required for leakage Class-I.

24

-

-

... More
Supply, installation, testing and balancing of Pressure Relief Dampers made out of 1.6 mm thick galvanized sheet steel frame and blades of 1.6 mm galvanised sheet steel with linkages capable of maintaining constant pressure at various airflows & close upon decrease in differential pressure. The damper shall be designed to provide pressure relief at 50 Pascals & 15 m/s velocity.

6

-

-

... More
Supply, installation, testing and commissioning of Motorized (ON-OFF Type) duct mounted GI volume control damper and necessary control wire (minimum 1.5 sqmm) for integration within AHU room / Equipment Volume Control damper may be without AMCA certification. However, OEM's Self Certification is required for leakage Class-I.

29

-

-

... More
Supply & installation of spring return type damper actuator with control panel along with BMS compatability for switch On/Off, Torque to be selected based on Damper size in N-m.

18

-

-

... More
Supply and installations Motorized Modulating type low leakage air dampers made out of 1.6mm thick galvanised steel frame & blade for fresh air modulation with actuator complete with all accessories like Actuator,control panel etc and any necessary requirement which can perform the controlling the Damper. It shall be integrated with Co2 sensor and based on CO2 levels, damper shall be modulate. (Co2 sensor provided by BMS scope). The damper shall be set at minimum 100 % fresh air supply and it shall modulate from 100 to 130 % fresh air supply as per the signals recieved from the CO2 sensor.

13

-

-

... More
Supply and installations testing & commissioning of actuator with control panel should be compatible for third party BMS integration, necessary fire integrator should be consider in part HVAC vendor scope.

76

-

-

... More
Fire Damper- Supplying, Fixing, testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications.Actuator selection sheet to be submitted for approval. Fire Dampers shall be CBRI certified as per UL 555S and self certiifcation shall be provided by OEM for leakage class 1 rating.

-

-

-

... More
Fire & Smoke damper with Sleeves as per specifications.

126

-

-

... More
Fire & Smoke damper without Sleeves as per specifications.

104

-

-

... More
Actuator - 5 Nm

236

-

-

... More
Actuator - 10 Nm

178

-

-

... More
Fusible Link

16

-

-

... More
Supply, installation of Back Draft Dampers made of 1.6 mm thick galvanised steel frame and blades of 1.6 mm galvanised sheet steel

20

-

-

... More
VAV BOXES WITH CONTROLS

-

-

-

... More
a) Supply, Installation, Testing & Commissioning of VAV boxes of following capacities & the capacities of the units with the below specification are as follows as per technical specifications with all the necessary mounting accessories as required for complete installation.as per specification/drawings and as directed by PMC/Employer. The quoted price shall be inclusive of the digital thermostat & control cabling for each VAV unit required for the functioning of the VAV system

-

-

-

... More
b) The casing shall be minimum 25 mm thick with insulation sandwich between double skin type of 22 SWG Galvanized sheet steel construction, with a completely sealed, easily removable. VAVs shall be pressure independent type & low velocity type. VAV Boxes shall be slow reacting type capable of delivering variable air volume type by the action of opposed blade volume control damper. VAV boxes shall be supplied with end flanges for attachment to flanged duct ends and shall be complete with all internal Acoustic treatment.The noise level from the VAV boxes shall not exceed 35dbA at 1.5 m distance

-

-

-

... More
c). VAV shall be electronically controlled networkable controller type complete with 16 G GSS low leakage damper, actuator, Microprocessor unit, wall/ ceiling mounted thermostat with ON/OFF Switch, control transformer, unit hander brackets etc.

-

-

-

... More
d). VAV Boxes shall also be able to reset any air flow between zero and the maximum air quantity that the boxes can handle without changing orifices or other parts, but the boxes shall be factory set at 10% of the maximum flow as minimum flow.

-

-

-

... More
e). The thermostat and the entire control mechanism shall be fully compatible with BMS System through LON Works/ Bacnet/ Modbus protocol. Datas like temperatures, set points, damper position shall be monitored through BMS system

-

-

-

... More
f). The VAV shall be suitable to operate on 230 V, single phase electrical supply. Damper actuator shall be able to accept 4-20 mA command signal from IBMS console and correspondingly modulate the damper position. Actuator shall also be able to provide position signal (4-20 mA) to IBMS console.

-

-

-

... More
150 CFM

1

-

-

... More
200 CFM

1

-

-

... More
250 CFM

2

-

-

... More
300 CFM

4

-

-

... More
350 CFM

2

-

-

... More
650 CFM

1

-

-

... More
1600 CFM

1

-

-

... More
2200 CFM

3

-

-

... More
LOWSIDE DUCT INSULATION MATERIALS

-

-

-

... More
Duct Acoustic Insulation - Supply and installation of (Accoustic) Duct liner (Insulation) of specified thickness of Open Cell Elastromeric Nitrile Rubber Insulation manafactured as per ASTM E 84 test & which should also meet NFPA 90A supplementary materials for air distribution system which should not absorbs less 0.2% water by volume (ASTM c 209), should not support microbial growth (ASTM C1071, G21, G22) and should emit objectionable odors (ASTM C 665) and should have thermal conductivity of 0.27 ( R - 2.78 in 3.4" thickness) and water vapor permeance of 0.10. - Class "1" Material-.All joints of the Insulation material should be further covered with 50 mm wide 3 mm thick self adhesive tape made of similar material & Black Cotton Tape shall not be used. Density shall be 140 -180 kg/m3 Thickness shall be 25mm

1450

-

-

... More
Duct Acoustic Insulation -Supply and fixing of acoustic lining of supply air duct and plenum with 25 mm thick resin bonded glass wool having density of 32 kg/m³, with 25 mm X 25 mm GI section of 1.25 mm thick, at 600 mm centre to centre covered with Reinforced Plastic tissue paper and 0.5 mm thick perforated aluminum sheet fixed to inside surface of ducts with cadmium plated nuts, bolts, stick pins, CPRX compound etc. complete as required and as per specifications.

200

-

-

... More
Duct Thermal Insulation - Supply and fixing of Duct / Floor Insulation of class " O " Closed cell nitrile rubber based elastomeric insulation with the density of 40 - 55 kg /m³ . The insulation manufactured as per BS 476 Part 6 & 7 should have thermal conductivity of 0.033W/m.k @ 0 deg C as per DIN EN 12667. and water vapor permeance of 0.10. Joints should be sealed with 50 mm wide & 3 mm thick Aluminium foil self adhesive tape (Black Cotton Tape not acceptable). Adhesive shall be used additionally with VOC level not exceeding 50 grms / Litre. for floor, ceiling, wall upt to false floor. As per specification/drawings and as directed by PMC/Employer. Note - Insulation shall be Anti-Microbial type, UL approved & must have factory laminated aluminium foil.

-

-

-

... More
9 mm - Supply / Return / Floor Insulation

200

-

-

... More
13 mm - Return Air Ducting

2950

-

-

... More
19 mm - Supply / Fresh Air Ducts through Conditioned Space

2700

-

-

... More
25 mm - Supply / Fresh Air Ducts through Un-conditioned Space

4200

-

-

... More
Duct Thermal Insulation (For Outdoor) - Supply and fixing of Floor Insulation of class " O " Closed cell nitrile rubber based elastomeric insulation with the density of 40 - 55 kg /m³ . The insulation manufactured as per BS 476 Part 6 & 7 should have thermal conductivity of 0.033W/m.k @ 0 deg C as per DIN EN 12667. and water vapor permeance of 0.10. Joints should be sealed with 50 mm wide & 3 mm thick Aluminium foil self adhesive tape (Black Cotton Tape not acceptable). Adhesive shall be used additionally with VOC level not exceeding 50 grms / Litre. for floor, ceiling, wall upt to false floor. The Insulation at Terrace shall be painted with UV Resistant Paint Note - Insulation shall be Anti-Microbial type, UL approved & must have factory laminated aluminium foil.

-

-

-

... More
25 mm - Supply / Fresh Air Ducts through Un-conditioned Space

470

-

-

... More
SITC of underdeck insulation for all AC areas exposed to directly Sun shall be provided with 50 mm thick TF quality Expanded Polystyrene slab or material of equivalent u value. The material shall be conform to IS:4671 & shall be of type ‘N’ unless specified otherwise. The apparent density shall be of 24 Kg/m³. The thickness of the material to be of 50mm. The vendor to include the cost of all material related to installation of the same for the top slab level with cleaning and making surface dust free, applying adhesive and providing 600x600 mm wire mesh grid with 26 G GI wire along with EPS slabs pasting on the surface. Vendor to ensure the installation as per PMC/Employers satisfaction.

3600

-

-

... More
Room Acoustic Insulation -Supply and fixing of acoustic lining with 50 mm thick resin bonded glass wool having density of 48 kg/m³, with 50 mm X 25 mm GI section of 1.25 mm thick, at 600 mm centre to centre covered with Reinforced Plastic tissue paper and 0.5 mm thick perforated aluminum sheet fixed to inside surface of ducts with cadmium plated nuts, bolts, stick pins, CPRX compound etc. complete as required and as per specifications.

4800

-

-

... More
Canvass connection : Supply, installation of Heavy duty double layered Canvass connection consisting of a flame retardnat fabric secured between galvanized sheet metal on either side by a double lock seam inserted between the equipment / Duct to provide wear resistant air tight flexible connection to eliminat vibrations, noise and rattles with fire rating EN532 and 533. The connection shall be 150mm in width. Only extra connections apart from those already mentioned in Fan Description shall be certified.

150

-

-

... More
FIRE SEALENT

-

-

-

... More
Supply and installation of Acrylic fire stop sealant CP606 or Approved Equivalent )with minimum 2 hours fire rating when tested in accordance with UL 1479 standards, shall be used along the periphery of ducts & chiller pipes without insulation passing through fire rated walls and floors made of concrete, masonry, metal, gypsum construction to provide up to 2 hours insulation and integrity when subject to the test conditions of UL 1479 standards. The product shall also be age tested as per DafStb guidelines. Sealant to provide sufficient MAF, water and gas tight seal apart from providing an airborne sound transmission reduction (STC of 50) and shall be tested as per DIN 52210 for sound insulation . The product should be tested for mold resistance rating of 0 as determined by ASTM G21-96 and should have a VOC content of approx. 75 g/l as per LEED 2009. The sealant shall be FM approved. All installations to be in full accordance with the manufacturer. The sealant should be tested in accordance with IEC 60068-2-57:1999-11 (Environmental Testing) as per Part 2-57: Test for Vibration-Time-history method and VERTEQII for seismic zone 4. The product shall bear the UL and FM approval logo on the packing where applicable. The rate shall include the mineral wool backing material and other miscellaneous items etc.., Assumed 15% Penetrants Ocupancy. Firestop installation should be done by HAFSC ( Accredated Firestop Speciality Contractor by providing complete installation report using CFS DM). Or using FIT (Firestop Installer Training) Program. As per IFC Guideliness EJ is recomended for non standard openings.-( supply & return air ducts.)

200

-

-

... More
Kitchen exhaust ducting and accessories

-

-

-

... More
MS Ducting - grade material 16 G with complete joints, & MS supports at every 1.5 mts capable of taking 600 kgs point load - Floor,Shaft & Terrace Area. Necessary scafollding required for erecting above within the shafts from 16th floor to terrace should be considered in the scope of works. Fire rated gasket material to be used for duct joining. Mockup to be provided for the duct support arrangement along with duct joints before going ahead.

600

-

-

... More
Grease Collection Box near the unit. Construction of Grease Collection Box should be similar to same as Ducting specified above

1

-

-

... More
20 Inches x 20 Inches Trap Door fabricated of same material / specs as Ducting specified above. Acess panel shall have a gasket which can sustain 1500 deg F (815 deg C) temperature. Same need to be located in the kitchen area, shafts , units etc

1

-

-

... More
Volume control Damper made out of MS material (higher than ducting material) for air balancing. Frame: High quality Stainless Steel sheet (Grade 304/316L) of thickness 16 G depending on size Frame shall be made of 125mm depth and standard flange height of 25mm. Blades shall be single skin ridge shaped blade constructed out of 16G thick S.S sheet as standard.

4

-

-

... More
Pressure relief damper for kitchen exhaust duct. In case of pressure build up in the kitchen, the damper shall release the pressure to the atmosphere. Needs to fixed on the exhaust duct near the exhaust fan with all accessories, supports, etc. Shall be made of 16 G GI of the following sizes.

1

-

-

... More
MS duct insulation with Al. Foil faced fibre glass wool 25 mm thick, 32 kg /m3 density

100

-

-

... More
Supply, installation, testing and commissioing of Emergency Lockable Push button station for the above, Fire rated type with required GI angle iron support

1

-

-

... More
Supply, installation, testing and commissioing of Emergency Lockable Push button station cabling for the above, 3 core 1.5 square XLPE copper armoud fire rated cable length shall be 100rmt between motor to Push button

1

-

-

... More
Supply, installation, testing and commissioing of MS channel support with two coat of enamal painting for Unit additonal supports, Support shall be with cushy foot mounting or spring mounting as per the manufacter standard

100

-

-

... More
Supply, installation and commissioning of Air curtains suitable for 230V/50Hz/AC power supply complete with aluminimum centrifugal flow fans wheel and double shaft motors, heavy duty to suit the following sizes of Rolling shutter/Door for dust barrier and for a minimum inside temperature of 29ºC internal barrier and noise level should not exceed more than 55dB (A). 6 feet length, Air Flow: 1300 m3/hr, Air Velocity : 21-25 m/s ; Noise level 60DB for (Door Ht. - 3.5 mtrs.)

1

-

-

... More
Supply, installation and commissioning of Air curtains suitable for 230V/50Hz/AC power supply complete with aluminimum centrifugal flow fans wheel and double shaft motors, heavy duty to suit the following sizes of Rolling shutter/Door for dust barrier and for a minimum inside temperature of 29ºC internal barrier and noise level should not exceed more than 55dB (A). 4 feet length, Air Flow: 1300 m3/hr, Air Velocity : 21-25 m/s ; Noise level 60DB for (Door Ht. - 3.5 mtrs.)

1

-

-

... More
Indoor Air quality testing (IAQ testing) for Parameter Such as VOC, CO2 and Bacteria Count After the installation of HVAC indoor units

1

-

-

... More
FIRE PROTECTION SYSTEM WORK

-

-

-

... More
FIRE PUMPS AND ACCESSORIES

-

-

-

... More
Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required : (a) Horizontal type, multistage/single, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520 /IS 12469. (b) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Suitable cement concrete foundation duly plastered with anti vibration pads. (e) Post Office Red / Fire Red color paint shall be as per specification/drawings and as directed by PMC/Employer (f) Note: The head of the pump is selected in a manner so as to give a minimum 3.5kg/cm2 at the highest/farthest point LOCATION: PUMP ROOM

-

-

-

... More
2850 lpm at 120 m Head

2

-

-

... More
Supply, installation, testing and commissioning of Diesel Engine Driven Main Fire Pump suitable for automatic operation and consisting of followings complete in all respects as required. a. 1 No. horizontal split casing centrifugal type fire pump capable of delivering 2850 LPM against a total head of 120 metres, so as to ensure a minimum pressure of 3.5 kg. per sq.cm at the farthest top most hydrant / outlet with pump casing of cast iron to grade FG 200, IS 210-1978 and parts like impeller, shaft sleeve, bearing ring, etc., of non-corrosive metal either like bronze, brass or gun metal and shaft of stainless steel. b. Suitable HP,1500 RPM water cooled with radiator, diesel engine conforming to relevant BS & IS standard complete. c. Auto starting mechanism, 12 volts / 24 volts electric starting equipment like self motor, dynamo, solenoid switches etc. d. Diesel engine's day oil tank shall be of capacity sufficient to hold fuel up to 6 hrs of engine operation and mounted over stand fabricated using 25mm x 25mm x 6mm size MS angle providing with level indicator, inlet port, outlet port, drain port and diesel return line port and fuel pre filter, after filter etc.First fill of all consumables including grease, lubricants, oil and diesel fuel. Contractor shall also refill all the consumables after successful testing at the time of handing over the system. e. Exhaust system having flexible metallic mufler, 150mm dia MS heavy pipe extended upto 10m height outside pump house duly insulated with 50mm thick glass wool with 1mm thick aluminium sheet cladding, residential silencer with necessary MS support arrangements from wall or ceiling as per site condition.

-

-

-

... More
f. Dash board consisting of the instruments like Temperature Gauge, Galvano Type DC Ammeter, Lubricant Oil Pressure Gauge, Ignition Switch, Emergency Stop and all other protection equipments as per specification, stop solenoid for auto stop in the event of fault with audio indications, g. 12 V / 24 V, storage battery, maintenance free tape, 180AH rating. MS fabricated common base plate, coupling guard, foundation bolts, etc., as required. h. Positioning the Diesel Engine Driven Fire Pump over cement concrete foundation using suitable size anti vibration mounting arrangements. i. Post Office Red / Fire Red shall be as per specification/drawings and as directed by PMC/Employer All works including conveying, fixing and incidental charges, etc., completed as per standard specification and as directed by the PMC/Employer. LOCATION: PUMP ROOM

-

-

-

... More
2850 lpm at 120 m Head

1

-

-

... More
Supplying, installation, testing and commissioning of Electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) (a) Vertical type, multistage/single, centrifugal split casing pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520. (b) Suitable HP squirrel cage induction motor TEFC type suitable for operation 2900 RPM on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS : 325. (c) M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. (d) Post Office Red / Fire Red color paint shall be as per specification/drawings and as directed by PMC/Employer (e) Note: The head of the pump is selected in a manner so as to give a minimum 3.5kg/cm2 at the highest/farthest point LOCATION: PUMP ROOM

-

-

-

... More
180 lpm at 120 m Head

2

-

-

... More
Supply, erection, testing and commissioning of fire fighting application monoblock motor pumpset of 900 LPM at 40 metres head to develop 3.5 kg/sq.cm at the heightest and farthest hydrant point to make 30 m water jet at the time of fire fighting emergency cicumstances, coupled with 11 KW / 15 HP rated three phase 414 volts, 50 Hz, 2880 rpm electrical motor the pump with cast ron body, bronze impeller, rope gland packaging, suction size of 80 mm dia. delivery size of 65 mm dia., including the cost of foundaton concrete anti vibration mounting, rain safety hood and etc. complete as directed by the PMC/Employer. M.S.fabricated common base plate, coupling, coupling guard, foundation bolts, with anti vibration pads. etc.as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. Post Office Red / Fire Red Paint shall be as per specification/drawings complete as directed by the PMC/Employer. LOCATION: TERRACE FLOOR

-

-

-

... More
900 lpm at 40 m Head

1

-

-

... More
PIPES WORK

-

-

-

... More
Supply, erection, testing and commissioning of following MS ‘C’ Class Heavy Duty Pipe as per IS 1239 / 3589 including necessary fittings like MS flange of table ‘E’ as per BS-10 standard, elbows, reducers, gaskets, bolt, nuts with washers & joints, Half coupling as per standard method of arc welding, including shade of finish paint shall be as per IS:5 , one coat metal primer (i.e. dry film thickness (DFT) 25 microns per coat) and two coat Post Office Red / Fire Red paint (i.e. minimum dry film thickness (DFT) 25 microns per coat. Total DFT 50 microns minimum.) as directed by PMC/Employer painting including conveyance, all incidental charges,neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found necessary, etc., complete as per standard specification and as directed by the PMC/Employer, NOTE:- 1. MS Fittings(40 mm dia. and below shall be Forged Steel fittings as per ASTM A 105 3000CL, end connection Socket welded as per ASME B16.11. & one side socket weld and other side threaded as per NPT for fittings used for sprinklers 2. M.S Fittings of 50 mm dia & above shall be as per ASTM A 234 Gr. WPB all fittings shall be BW seamless fittings type as per specifications. 3.All Fire pipe headers/riser shall be worded indicating the direction of the flow and its purpose such as "TO RISER NO.1" as per PMC/Employer /CFO requirement etc. 4. Pipe Support for pipe size 65mm & below shall be G.I Universal clamps with threaded rod. For pipe size 80mm & above, the support shall be Clevis Hanger with threaded rod. Where a group of pipes run together they shall be supported with Galvanized Iron structure support. 5. Contractor shall perform appropriate calculations and design the structural pipe supports. Universal clamps and Clevis hangers shall be selected for the appropriate load. 6.Cost Should include MS 'C' channel Duly epoxy coated installed below pipe, a 'U' Clamp to arrest the pipe on pedestals. 7.The cost should include the painting of the MS angle frame. LOCATION: SPRINKLER & HYDRANT SYSTEM

-

-

-

... More
300 mm dia

32

-

-

... More
250 mm dia

53

-

-

... More
200 mm dia

53

-

-

... More
150 mm dia

2060

-

-

... More
100 mm dia

1544

-

-

... More
80 mm dia

1224

-

-

... More
65 mm dia

1229

-

-

... More
50 mm dia

1575

-

-

... More
40 mm dia

2106

-

-

... More
32 mm dia

2064

-

-

... More
25 mm dia

11947

-

-

... More
20 mm dia

237

-

-

... More
15 mm dia

168

-

-

... More
Providing, Laying, Testing & Commissioning of 'B' class medium duty G.I. Pipe conforming to IS 1239 including welding, fitting like elbows, tees, MS flange of table ‘E’ as per BS-10 standard, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and including shade of finish paint shall be as per IS:5 , one coat metal primer (i.e. dry film thickness (DFT) 25 microns per coat) and two coat Post Office Red / Fire Red paint (i.e. minimum dry film thickness (DFT) 25 microns per coat. Total DFT 50 microns minimum.) as directed by PMC/Employer painting including conveyance, all incidental charges,neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found necessary, etc., complete as per standard specification and as directed by the PMC/Employer, NOTE:- 1. G.I Fittings(40 mm dia. and below shall be Forged Steel fittings as per ASTM A 105 3000CL, end connection Socket welded as per ASME B16.11. & one side socket weld and other side threaded as per NPT for fittings used for sprinklers 2. G.I Fittings of 50 mm dia & above shall be as per ASTM A 234 Gr. WPB all fittings shall be BW seamless fittings type as per specifications. 3.All Fire pipe headers/riser shall be worded indicating the direction of the flow and its purpose such as "TO RISER NO.1" as per PMC/Employer /CFO requirement etc. 4. Pipe Support for pipe size 65mm & below shall be G.I Universal clamps with threaded rod. For pipe size 80mm & above, the support shall be Clevis Hanger with threaded rod. Where a group of pipes run together they shall be supported with Galvanized Iron structure support. 5. Contractor shall perform appropriate calculations and design the structural pipe supports. Universal clamps and Clevis hangers shall be selected for the appropriate load. LOCATION: SPRINKLER & HYDRANT DRAIN

-

-

-

... More
50 mm dia

756

-

-

... More
80 mm dia

654

-

-

... More
100 mm dia

21

-

-

... More
Providing, laying, testing and commissioning of Centrifugally cast (spun) Ductile Iron pipe with tyton jointed class "K9" confirming to IS 8329 with class K12 fittings confirming to IS 9523 including metallic zinc coating and finished layer of bituminous paints, fittings, elbows, nuts, bolts, gaskets etc. in ground including excavation & providing cement concrete block as supports like anchor block / thrust block, concrete bedding etc. of following sizes complete as required and as per technical specifications. NOTE: 1.All Above ground Hydrant pipe headers/riser shall be worded indicating the direction of the flow and its purpose such as "TO RISER NO.1" as per PMC/Employer /CFO requirement etc. 2.one coat metal primer and two coat Post Office Red / Fire Red as directed by PMC/Employer painting including conveyance, all incidental charges. 3. The pipe shall not be less than 1.0 m below ground level at any point. 4. Laying and Jointing of DI pipes and fittings shall be done as per IS: 12288 and manufacturer’s recommendations. 5. M.S to D.I Flanged connection as per IS 8329 LOCATION: EXTERNAL HYDRANTS SYSTEM

-

-

-

... More
200 mm

210

-

-

... More
150 mm

447

-

-

... More
100 mm

228

-

-

... More
4mm thick Wrapping and Coating Anti-Corrosive Treatment for under ground MS pipe having one coat of anti-corrosive metal primer, one layer of asphalt tar tape wound over the MS pipe as per standard methods as per standard specification as directed by the PMC/Employer.

-

-

-

... More
100mm dia

10

-

-

... More
80mm dia

20

-

-

... More
VALVES

-

-

-

... More
Supplying, fixing, testing & commissioning of Double flanged Sluice valve of rating PN 16 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 14846 / IS 780 of following sizes as required : NOTE : Post Office Red / Fire Red paint shall be as per specification/drawings and as directed by PMC/Employer LOCATION: PUMP ROOM

-

-

-

... More
200 mm dia

1

-

-

... More
150 mm dia

6

-

-

... More
100 mm dia

3

-

-

... More
80 mm dia

1

-

-

... More
Supplying, fixing, testing & commissioning of Double flanged Sluice valve of rating PN 20 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 14846 / IS 780 of following sizes as required : NOTE: Post Office Red / Fire Red shall be as per specification/drawings and as directed by PMC/Employer LOCATION: PUMP ROOM

-

-

-

... More
300 mm dia

2

-

-

... More
250 mm dia

4

-

-

... More
200 mm dia

9

-

-

... More
150 mm dia

5

-

-

... More
100 mm dia

1

-

-

... More
80 mm dia

2

-

-

... More
65 mm dia

2

-

-

... More
Supplying, fixing, testing and commissioning of Butterfly valve of PN 16 rating with C.I body , Cast Bronze or Stainless Steel disc, stainless steel shaft, Either integral or Nitrile rubber seat , Nitrite/ Silicon O-ring duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : NOTE: Post Office Red / Fire Red shall be as per specification/drawings and as directed by PMC/Employer LOCATION: PUMP ROOM, ALL FLOORS

-

-

-

... More
200 mm dia

5

-

-

... More
150 mm dia

54

-

-

... More
100 mm dia

91

-

-

... More
80 mm dia

7

-

-

... More
65 mm dia

2

-

-

... More
50 mm dia

1

-

-

... More
Supplying, fixing, testing and commissioning of Butterfly valve of PN 20 rating with C.I body , Cast Bronze or Stainless Steel disc, stainless steel shaft, Either integral or Nitrile rubber seat , Nitrite/ Silicon O-ring duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : NOTE: Post Office Red / Fire Red Paint shall be as per specification/drawings and as directed by PMC/Employer LOCATION: PUMP ROOM

-

-

-

... More
200 mm dia

2

-

-

... More
150 mm dia

12

-

-

... More
100 mm dia

1

-

-

... More
80 mm dia

1

-

-

... More
65 mm dia

1

-

-

... More
50 mm dia

1

-

-

... More
Supply, lnstallation, Testing and Commissioning of Tamper Switch for Butterfly valves with BMS compatible of the following diameters complete with all necessary accessories, the tamper switch shall be provided with potential free contact with 2 nos. NO/NC as per specification/drawings and as directed by PMC/Employer. LOCATION: SPRINKLER RISER TAPPING AT EACH FLOOR

-

-

-

... More
150 mm dia

33

-

-

... More
100 mm dia

46

-

-

... More
80 mm dia

7

-

-

... More
Supply, lnstallation, testing and Commissioning of Male/ female screwed end full way lever operated forged brass Ball valve of PN 16 rating brass body with forged brass hard chrome plated ball & teflon seat, with (threaded joints) complete as required. including necessary teflon tape etc complete as per specification as specified inclusive of all accessories required for satisfactory installation as per specification/drawings and as directed by PMC/Employer. NOTE: Post Office Red / Fire Red paint shall be as per specification/drawings and as directed by PMC/Employer LOCATION: ALL FLOOR

-

-

-

... More
50 mm dia

84

-

-

... More
40 mm dia

2

-

-

... More
32 mm dia

2

-

-

... More
25 mm dia

2

-

-

... More
20 mm dia

95

-

-

... More
Supply, lnstallation, testing and Commissioning of Male/ female screwed end full way lever operated forged brass Ball valve of PN 20 rating brass body with forged brass hard chrome plated ball & teflon seat, with (threaded joints) complete as required. including necessary teflon tape etc complete as per specification as specified inclusive of all accessories required for satisfactory installation as per specification/drawings and as directed by PMC/Employer. NOTE: Post Office Red / Fire Red paint shall be as per specification/drawings and as directed by PMC/Employer LOCATION: PUMP ROOM

-

-

-

... More
50 mm dia

5

-

-

... More
40 mm dia

2

-

-

... More
32 mm dia

2

-

-

... More
25 mm dia

5

-

-

... More
20 mm dia

5

-

-

... More
Providing, installation, testing and commissioning of non-return valve of PN 16 rating of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : NOTE: Post Office Red / Fire Red paint shall be as per specification/drawings and as directed by PMC/Employer LOCATION: ALL FLOOR

-

-

-

... More
150 mm dia

6

-

-

... More
100 mm dia

5

-

-

... More
80 mm dia

1

-

-

... More
65 mm dia

1

-

-

... More
Providing, installation, testing and commissioning of non-return valve of PN 20 rating of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : NOTE: Post Office Red / Fire Red shall be as per specification/drawings and as directed by PMC/Employer LOCATION: PUMP ROOM

-

-

-

... More
200 mm dia

4

-

-

... More
150 mm dia

3

-

-

... More
100 mm dia

1

-

-

... More
80 mm dia

2

-

-

... More
65 mm dia

2

-

-

... More
Supply, erection, testing and commissioning of Air Release Valve of 20mm dia, so as to release airlock in 150 mm dia MS pipe at top most wet riser, including conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition wherever found necessary, etc., complete as per standard specification and as directed by the PMC/Employer LOCATION: PUMP ROOM, SPRINKLER RISER

6

-

-

... More
Providing, installation, testing and commissioning of Stainless Steel body Y- strainer screen fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with Stainless Steel flange. NOTE: Post Office Red / Fire Red paint shall be as per specification/drawings and as directed by PMC/Employer LOCATION: PUMP ROOM, TERRACE

-

-

-

... More
300 mm dia

2

-

-

... More
250 mm dia

2

-

-

... More
200 mm dia

1

-

-

... More
150 mm dia

1

-

-

... More
Supplying and fixing of Air vessel made of 250 mm dia, 8mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required. NOTE: Post Office Red / Fire Red shall be as per specification/drawings and as directed by PMC/Employer LOCATION: PUMP ROOM, HYDRANT RISER AT TERRACE

9

-

-

... More
Supply, lnstallation, testing and Commissioning of UL Listed/FM Approved pilot operated Pressure relief valve - of Ductile Iron body,Brass trim,Buna-N Synthetic Rubber with Direct Acting - Precise Pressure Control,Drip Tight Closure,drain arrangement. It shall have adjustable setting in range suitable for operating range of the pump. The relief valve outlet shall be led back to the tank. All accessories nuts, bolts, washer, connector and pipe fittings etc. as per specification/drawings and as directed by PMC/Employer. NOTE: Post Office Red / Fire Red paint shall be as per specification/drawings and as directed by PMC/Employer LOCATION: PUMP ROOM

-

-

-

2

-

-

1

-

-

... More
Providing and fixing UL listed Pressure reducing valve set for Sprinkler system comprising of 1 No pilot valve,2 Nos C.I Butterfly valves on inlet & outlet, 1 No. UL listed pressure reducing valve with flanged connection, 2 Nos Pressure gauge on inlet & outlet. The complete system is tested to a pressure not less than 18 Kg/Sq.cm and suitable to reduce the pressure upto 3.5 Kg/Sq.cm) Including flanges/ unions, nuts, bolts and washers complete as required as per specification/drawings and as directed by PMC/Employer. NOTE: The PRV shall be installed in an accessible location. Inlet Pressure: Max. 12 Kg/Sq.cm Outlet Pressure: 9.5 Kg/Sq.cm LOCATION: PUMP ROOM FOR ICV

-

-

-

... More
150 mm dia (Brass Housing - PRV)

1

-

-

... More
Supply, lnstallation, testing and Commissioning heavy duty floating flange EPDM rubber expansion joint with unit control (tie rod & gusset plate) as per manufacturers specifications of standard length complete with all accessories tested to a pressure not less than 15 Kg./sqcm including rubber gaskets, flanges, nuts, bolts & washers complete as required as per specification/drawings and as directed by PMC/Employer. LOCATION: PUMP ROOM

-

-

-

... More
200 mm dia

3

-

-

... More
150 mm dia

5

-

-

... More
100 mm dia

1

-

-

... More
80 mm dia

2

-

-

... More
65 mm dia

2

-

-

... More
Providing & fixing bronze Globe valve, PN16, conforming to IS 778 screwed in bonnet, Bronze body, disc & stem union flanges, washer nuts & bolts, rising stem, connectors, adapters etc. complete, high quality PTFE gland packing with necessary unions, complete as per specification/drawings and as directed by PMC/Employer. LOCATION: ALL FLOORS

-

-

-

... More
15 mm dia

2

-

-

... More
20 mm dia

97

-

-

... More
25 mm dia

1

-

-

... More
Providing & fixing bronze Globe valve, PN 20, conforming to IS 778 screwed in bonnet, Bronze body, disc & stem union flanges, washer nuts & bolts, rising stem, connectors, adapters etc. complete, high quality PTFE gland packing with necessary unions, complete as per specification/drawings and as directed by PMC/Employer. LOCATION: PUMP ROOM

-

-

-

... More
15 mm dia

1

-

-

... More
20 mm dia

13

-

-

... More
25 mm dia

3

-

-

... More
INSTRUMENTATION

-

-

-

... More
Supply, erection, testing and commissioning of suitable Pressure Switch of approved make including necessary valves, couplings, etc., connected with electrical main control panel and setup at proper differential so as to auto start and auto stop the electrical motor, jockey motor including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., completed as per standard specification and as directed by the PMC/Employer. NOTES: Adjustable type pressures switches suitable for operating with hydrant, water curtain & sprinkler systems for working pressure of 18Kg/cm² pressure including electrical wiring complete as required. Vendor also need to submit the calibration certificate of Pressure switch. LOCATION: PUMP ROOM

14

-

-

... More
Supply & installation of Pressure gauge(suitable for working pressure of (0-20 Kg/cm2(g)) of Stainless Steel with 6 inch phenolic dial (white dial with black numerals), 316 SS Bourdon tube, nylon movements and micrometer type adjustable aluminium pointer with accuracy of +/-0.1% of span including accessories like siphons for steam services, snubbers for pump discharge applications and chemical diaphragm for corrosive and oil services and name plate, etc. Material of accessories shall be SS. IP65 degree of protection for enclosure. Over range protection shall be 50% above maximum pressure. Armoured capillary of 15 M shall be provided as per specification. LOCATION: PUMP ROOM, ALL FLOORS FHC

118

-

-

... More
Supply, lnstallation, testing and Commissioning of FM approved Venturi Type Flow Test Meter on Test Line to measure 150% of pump flow and suitable for mounting on 150 mm dia pipe as per specification/drawings and as directed by PMC/Employer. LOCATION: PUMP ROOM

2

-

-

... More
HYDRANT ACCESSORIES

-

-

-

... More
Supply and fixing of Fire fighting application oblique type Single Headed Stainless Steel Hydrant Valve of size 63mm dia with oblique type instantaneous coupling with rotating wheel to open and close the valve including MS flange of table “E” as per BS-10 standard, bolts & nuts with washer as per IS 5290 at ring main around the building and wet riser inside the building including conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition wherever found necessary etc complete as per standard specification and as directed by the PMC/Employer LOCATION: ALL FLOORS FHC SHAFT

87

-

-

... More
Supplying and fixing Single Headed External Yard Hydrant Valve with 1 No. 63 mm dia instantaneous FM Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Stainless Steel cap and chain as required : LOCATION: EXTERNAL YARD HYDRANTS

15

-

-

... More
Supply, and fixing in position of Fire Fighting Application 63mm dia Stainless Steel Short length Branch Pipe with hexagonal type spray nozzle of 20mm jet bore. Near every hydrant points including conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition wherever found necessary, etc., complete as per standard specification and as directed by the PMC/Employer. LOCATION: ALL FLOORS FHC SHAFT , EXTERNAL YARD HYDRANTS

102

-

-

... More
Supply, and fixing in position of Fire Fighting Application RRL Type-A Hose confirming to IS 636 of 63mm dia of 15 metres length binded by copper wire with 63mm dia stainless steel (Grade 304) male and female instantaneous fire fighting special coupling as per IS 901 as directed by the PMC/Employer Near every hydrant points including conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition wherever found necessary etc complete as per standard specification and as directed by the PMC/Employer. LOCATION: ALL FLOORS FHC SHAFT , EXTERNAL YARD HYDRANTS

203

-

-

... More
Supply, installation of Fire Fighting Application 180 degree swinging type, hose reel drum painted in post office red conforming to IS 884 with 20mm dia braided thermoplastic hose as per IS 12585 of 30 metres long, so as to extend to necessary distance by self rolling spindle wheel including necessary 20mm dia ball valve and open and close spray nozzle, warm clip, etc., as per the standard pattern of any approved make at every floor nearer to hydrant valve, including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary., etc., complete as per standard specification and as directed by the PMC/Employer. LOCATION: ALL FLOORS FHC SHAFT

87

-

-

... More
Supply of Fire Fighting Application MS Hose Box to keep two number of hoses and 1 No. of branch pipe with nozzle having proper glass window type double door with universe open key, painted inside white and outside Post Office Red. Near every hydrant point including conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition wherever found necessary, etc., complete as per standard specification and as directed by the PMC/Employer NOTE: 1.16 swg. with glass fronted ( 4mm thick glass with rubber beading) door and size of the cabinet shall be 600mm x 750 mm x 250 mm 2.Floor mounted / Wall mounted hose cabinets shall be provided with minimum 1 m high structural support legs of ISMC 100 as per the standard drawing. 3.Canopy (sloping top) is required for hose cabinets to be located outdoors. 4.The word “fire”, in 150 mm letter size in red, shall be painted on the cabinet glass. 5.The cabinet shall be provided with clamps for holding branch pipe, nozzle and hose reel where applicable. 6.Provision to keep one key and one hammer in glass covered recess on the side of the cabinet shall be made. 7.The colour shall be uv resistant fade proof integral type suitable for external atmosphere. LOCATION: EXPOSED FHC SHAFTS & EXTERNAL HYDRANT SYSTEM

15

-

-

... More
Providing & fixing lockable Indoor type Fire Hose Cabinet, frames fabricated from 40 x 40 x 5 angle iron sections and 16 gauge MS sheet with glass door (with M.S. frame) and locking arrangement, suitable to accommodate landing valves, 2 nos. 15 m long hoses, first-aid hose reel and branch pipe nozzle & fire mans’ axe. The cabinet frame shall be painted with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade of as required (Approx. 1.5 m (high) x 0.9 m (wide) x 0.6 m (deep) ). The item shall be complete of MS housing with front door Colour/shade of Paint shall be as per specification/drawings and as directed by PMC/Employer . LOCATION: EXPOSED FHC SHAFTS

7

-

-

... More
Supplying and fixing standard Fireman Axe with heavy duty insulated rubber handle as per IS: 926 with clamps as per specifications LOCATION: ALL FLOORS FHC SHAFT , EXTERNAL YARD HYDRANTS

102

-

-

... More
Supply, erection, testing and commissioning of Fire Fighting Fire Brigade Inlet & drawout with necessary gun metal 63mm dia instantaneous inlet couplings complete with cap and chain as reqd for suitable dia GI pipe connection conforming to IS 904 as required and non return spring shutter arrangements, so that to control one way flow at the time of emergency water supply by fire and rescue service fire engine entry including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the PMC/Employer. LOCATION: EXTERNAL

-

-

-

... More
(a) 2 way-100 mm dia G.I. Pipe (Drawout)

1

-

-

... More
(b) 4 way - 150 mm dia G.I. Pipe (Inlet)

5

-

-

... More
Providing & fixing SS cabinet (to enclose Fire Brigade and draw-out connection as per Item above) fabricated from 16 g SS 304 sheet with full front glass door and locking arrangement duly painted with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade and suitably mounted on a raised masonry platform as required (Approx. 0.6 m x 0.6 m x 0.45 m) LOCATION: EXTERNAL

6

-

-

... More
Supply, erection, testing and commissioning of following sizes of CI flanged end Heavy Duty Foot Valve as per IS 4038/1979 including all accesories, such as, MS flange of table ‘E’ as per BS-10 standard, gaskets, bolts & nuts, etc., installed at end of 100/ 150 / 200mm dia suction pipe line at sump including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete and as per standard specification and as directed by the PMC/Employer. LOCATION: UNDER GROUND FIRE WATER & DOMESTIC WATER TANK

-

-

-

... More
Size: 100 mm dia

4

-

-

... More
Supplying and fixing Orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required as per specifications. NOTE: The bore of the orifice shall be designed by the Contractor in order to get hydrants valve outlet pressure of 3.5 kg/cm2”. LOCATION: FHC SHAFTS AS REQUIRED , EXTERNAL YARD HYDRANTS

54

-

-

... More
Supply & Fixing of " J " type hooks supports made of 25 mm dia MS pipe to support 2 Number 15 m long hoses and 1 Number short branch pipe. Cost should be inclusive of required anchor fastener, nuts, etc as per specifications LOCATION: FHC SHAFTS

87

-

-

... More
AUTOMATIC SPRINKLER SYSTEM

-

-

-

... More
Providing, fixing, testing & commissioning of Installation control valve of Cast Iron body, 17.5 kg/sq.m brass/bronze working parts comprising of water motor alarm, SS-304 clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of following sizes as required : NOTE: Post Office Red / Fire Red color paint shall be as per specification/drawings and as directed by PMC/Employer LOCATION: PUMP ROOM

-

-

-

... More
150 mm dia

2

-

-

... More
Supply, lnstallation, testing and Commissioning of UL Listed Zone/Floor Control Valve flanged end with fitting, suitable for working pressure of 18kg/sq.m including 50 mm Inspectors test drain valve assembly complete with test bronze valve, bronze sight glass, sectional drain valve, union with pressure gauge, electrically operated flow indicating switch (vane type) of following diameter with threaded connection with flexible full bore paddle & NO/NC contact terminals with all accessories and necessary wiring all complete strictly as per specification/Drawing as per specification/drawings and as directed by PMC/Employer. LOCATION: SPRINKLER SYSTEM ALL FLOORS

-

-

-

... More
Dia 150 mm dia

33

-

-

... More
Dia 100 mm dia

48

-

-

... More
Dia 80 mm dia.

7

-

-

... More
Supply, lnstallation, testing and Commissioning of UL Listed/FM Approved 15 NB, 93 deg. , K-Factor 5.6 (80), Pendant type, Standard Response, Quartzoid bulb sprinkler with adjustable rosette plate, teflon tape, lock tite solution with required accessories etc. complete as per specification/drawings and as directed by PMC/Employer. LOCATION: KITCHEN

48

-

-

... More
Supply, lnstallation, testing and Commissioning of UL Listed/FM Approved 15 NB, with 68°C. temperature rating for Sprinkler bulb and 57°C. for Cover Plate, K-Factor 5.6 (80), Pendant type, Standard Response, Quartzoid bulb sprinkler adjustable royal flush Concealed sprinkler, teflon tape, lock tite solution with required accessories etc. complete as per specification/drawings and as directed by PMC/Employer. LOCATION: ALL FLOORS COMMON AREAS

928

-

-

... More
Supply, lnstallation, testing and Commissioning of UL Listed/FM Approved 15 NB, with 68°C. temperature rating for Sprinkler bulb and 57°C. for Cover Plate, K-Factor 8 (115), Pendant type, Standard Response, Quartzoid bulb sprinkler adjustable royal flush Concealed sprinkler, teflon tape, lock tite solution with required accessories etc. complete as per specification/drawings and as directed by PMC/Employer. LOCATION: DOUBLE HEIGHT AREAS

203

-

-

... More
Supply, lnstallation, testing and Commissioning of UL Listed/FM Approved 15 NB, 68 deg. , K-Factor 5.6 (80), Upright type, Standard Response, Quartzoid bulb type sprinkler Coverage Area 9 sq.mtr, teflon tape, lock tite solution with required accessories etc. complete as per specification/drawings and as directed by PMC/Employer. LOCATION: GROUND AND ABOVE FLOORS

4358

-

-

... More
Supply, lnstallation, testing and Commissioning of UL Listed/FM Approved 15 NB, 68 deg. , K-Factor 5.6 (80), Side wall type, Standard Response, Quartzoid bulb, recessed type sprinkler with adjustable rosette plate, Standard Coverage, teflon tape, lock tite solution with required accessories etc. complete as per specification/drawings and as directed by PMC/Employer. LOCATION: FACADE GLAZING

1181

-

-

... More
Supply, lnstallation, testing and Commissioning of UL Listed/FM Approved 15 NB, 68 deg. K 5.6 (80), Pendant type, Standard Response, Quartzoid bulb sprinkler with adjustable rosette plate, teflon tape, lock tite solution with required accessories etc. complete as per specification/drawings and as directed by PMC/Employer. LOCATION: GROUND AND ABOVE FLOORS

158

-

-

... More
Supply, lnstallation, testing and Commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. LOCATION: FOR ALL PENDANT SPRINKLERS

-

-

-

69

-

-

... More
1000mm

130

-

-

... More
1200mm

1314

-

-

... More
Supply, lnstallation, testing and Commissioning of Sprinkler annunciation panel 230 V AC input, 50 Hz AC supply & 24 VDC output, standby 24 V DC, operating temperature 00C to 400C which shall be of micro processor based with LED indicators, comprising with Modular PCB board type visual and audible fire and fault alarms and signals, indicators, call individual or call all, Evacuation alarm facility with pulse timer, Power supply unit etc., complete with stove enameled housing, glass door with locking facility as per detailed specification. located in the lobby area as per the drawing. The Annunciation Panel shall be complete with 2 x 12 VDC sealed maintenance free batteries with battery charger & housed in CRCA sheet steel cabinet (3 mm thick), dust & vermin proof(IP 65) with provision for audio-visual indication. The Annunciation Panel shall be provided with Potential free contacts to enable BMS compatibility kept to main power panel interlink of Ethernet port, along with patch card readable to BMS as per specification/drawings and as directed by PMC/Employer. LOCATION: GROUND FLOOR FCC ROOM

-

-

-

... More
64 Zones

2

-

-

... More
Supply, laying, termination, testing and Commissioning of armoured FRLS control wires 2C x 1.5 sqmm made of PVC insulated copper conductor, PVC sheathed,confirming to IS 1554 etc. shall include all fittings, jointing, glands, lugs, bracing, clamping, fastening, chasing, termination and testing. complete as per specification/drawings and as directed by PMC/Employer.

10928

-

-

... More
Supply, laying, termination, testing and Commissioning of armoured FRLS control wires 2C x 2.5 sqmm made of PVC insulated copper conductor, PVC sheathed,confirming to IS 1554 etc. shall include all fittings, jointing, glands, lugs, bracing, clamping, fastening, chasing, termination and testing. complete as per specification/drawings and as directed by PMC/Employer.

220

-

-

... More
Providing & fixing spare sprinkler MS cabinet fabricated from 16 gauge MS sheet (duly painted over a coat of primer) with full front glass door & locking arrangement with suitable shealves for keeping spare sprinkler of each type (as desired below) & two nos spanner properly fixed in shelves. Cost shall be for individual cabinet comprising of spare sprinkler stored as indicated below :

-

-

-

... More
UL Listed/FM Approved 15 NB, 93 deg. , K-Factor 5.6 (80), Pendant type, Standard Response, Quartzoid bulb sprinkler

25

-

-

... More
UL Listed/FM Approved 15 NB, with 68°C. temperature rating for Sprinkler bulb and 57°C. for Cover Plate, K-Factor 5.6 (80), Pendant type, Standard Response, Quartzoid bulb sprinkler adjustable royal flush Concealed sprinkler

25

-

-

... More
UL Listed/FM Approved 15 NB, with 68°C. temperature rating for Sprinkler bulb and 57°C. for Cover Plate, K-Factor 8 (115), Pendant type, Standard Response, Quartzoid bulb sprinkler adjustable royal flush Concealed sprinkler

25

-

-

... More
UL Listed/FM Approved 15 NB, 68 deg. , K-Factor 5.6 (80), Upright type, Standard Response, Quartzoid bulb type sprinkler

25

-

-

... More
UL Listed/FM Approved 15 NB, 68 deg. , K-Factor 5.6 (80), Side wall type, Standard Response, Quartzoid bulb, recessed type sprinkler

25

-

-

... More
UL Listed/FM Approved 15 NB, 68 deg. K 5.6 (80), Pendant type, Standard Response, Quartzoid bulb sprinkler

25

-

-

... More
CLEAN AGENT BASED FIRE SUPPRESSION SYSTEM

-

-

-

... More
CLEAN AGENT BASED FIRE SUPPRESSION SYSTEM Assumed Areas to be protected:- IBMS SERVER ROOM AT SECOND FLOOR - APPROXIMATE 10000 MM (L) X 6500 MM (W) X 4200 MM (H)- 1 Number NOTE:- 1-System to be designed with Individual Risk with Main + Standby System 2-100% online Stand-by cylinders of clean agent shall be provided for restoring the area protection after discharge of main bank of cylinders. 3-Clean Agent Gas based suppression system shall be halon Free. LOCATION: SECOND FLOOR

-

-

-

... More
Design, Supply, Installation, Testing & Commissioning of CCOE/PESO Approved UL/ FM/ VDS Listed agent FK-5-1-12 or equivalent Cylinder and Valve Assembly,120 Ltrs Ltr seamless cylinder capacity, Liquid at site (fill density not more than 0.89Kg/ litre), pressurised to 25 / 42 bar along with Hydraulic UL/ VD Flow Calculations for the Suppression areas, and vetting of the Software from the OEM Factory Engineer as per specification/drawings and as per specification/drawings and as directed by PMC/Employer . Below compliance are mandatory to comply with PESO, Gas cylinder rule and compressed gas cylinder rule. a) PESO License for Valve & b) PESO License for Cylinder

4

-

-

... More
The fire suppression agent FK-5-1-12 or equivalent . The Hydraulic software report should have the dead volume agent quantities reflected for IBMS Server Room as per UL 2166 testing and approval standard as per specification/drawings and as directed by PMC/Employer .

464

-

-

... More
Supply, Installation, Testing & Commissioning of Tank Bracket Assembly complete with C Channel Stand and Supports for above Cylinder as per specification/drawings and as directed by PMC/Employer. The Price Shall include MS Fabricated Floor Supported Cylinder Support Stand, wherever Required complete with 1 coat of Primer and 2 coat of Black Enamel Paint.

-

-

-

... More
Cylinder Bracket with C Chanel from OEM supply

8

-

-

... More
MS Fabrication floor support for cylinder stand 150mm above floor level with 1 coat of primer and 2 coat of Black Enamel Paint.

4

-

-

... More
Supply, Installation, Testing & Commissioning of UL/ VDS Listed Discharge hose with Manifold Check Valve (Check Valve if More than one Cylinder in Bank) for above Cylinders, complete with Listed Actuation Hose, Swivel, stainless Braided, 24in , 1/4in Female, Male adaptor (1/4" BSPT x 1/4" BSPP), Male elbow (1/4" NPT x 1/4" BSPP ) & Accessories as required as per specification/drawings and as directed by PMC/Employer.

4

-

-

... More
Supply, Installation, Testing & Commissioning of UL/ FM/ VDS Listed Electrical Actuator with placement indicator switch for Master Cylinder as per NFPA requirement and as per specification/drawings and as directed by PMC/Employer.

6

-

-

... More
Supply, Installation, Testing & Commissioning of UL/ VDS Listed Local Manual Actuator as per specification/drawings and as directed by PMC/Employer .

6

-

-

... More
Supply, Installation, Testing & Commissioning of UL/ VDS Listed Pneumatic Actuator Shipping Assembly with actuation hose & Elbow as per specification/drawings and as directed by PMC/Employer.

6

-

-

... More
Supply, Installation, Testing & Commissioning of UL/ VDS Listed Nozzles, 360 Deg / 180 Deg Throw, selection as per approved hydraulic flow calculations. The sound pressure developed by discharge of total number of nozzles in each area needs to be submitted considering the distance between server rack and nozzle distance as 1 mtr. Software calculations for sound pressure to be submitted. - as per specification/drawings and as directed by PMC/Employer .

-

-

-

... More
Standard Nozzle 15mm

11

-

-

... More
Standard Nozzle 20mm

3

-

-

... More
Standard Nozzle 25mm

3

-

-

... More
Standard Nozzle 32mm

5

-

-

... More
Supply, Installation, Testing & Commissioning of Warning Sign Board of of size 150mm X 400mm with Marking "GAS DISCHARGE. DO NOT ENTER".Shall Operate on 24 V DC, Driven Through Gas Release Panel. (for use outside room)as per specification/drawings and as directed by PMC/Employer .

6

-

-

... More
Supply, Installation, Testing & Commissioning of Warning Sign Board of of size 150mm X 400mm with Marking "GAS DISCHARGE. EVACUATE IMMEDIATELY". Shall Operate on 24 V DC, Driven Through Gas Release Panel. (for use inside room) as per specification/drawings and as per specification/drawings and as directed by PMC/Employer .

6

-

-

... More
Supply, Installation, Testing & Commissioning of UL/ VDS Listed Cylinder Low Pressure Switchs per specification/drawings and as directed by PMC/Employer.

4

-

-

... More
Supply, Installation, Testing & Commissioning of UL/ VDS Listed Cylinder Discharge Pressure Switch, Shall be install on the piping after discharge hose as per specification/drawings and as directed by PMC/Employer.

6

-

-

... More
Supply, Installation, Testing & Commissioning of Piping & Manifold as required, Sch 80; ASTM A106 Gr B, as per flow calculations for the specific hazard volume and stand to hold,position & Support the Manifold and Piping properly including Pressure testing for piping with nitrogen as per NFPA 2001 as per specification/drawings and as directed by PMC/Employer.

-

-

-

... More
Supply & Installation of Manifold fabricated out of Sch 80 pipe with 150 mm pipe with 1 port main and 1 port standby cylinders. The Manifold should include all the support and fittings.

6

-

-

... More
Supply, Installation, Testing & Commissioning of Seamless Pipe Sch 40 distribution pipe along which shall include all the support and fittings for pipes like U Clamps, Elbows, Sockets, Reducers, Tees, Flanges, Fasteners etc.for pipes for 7 cylinder system as per specification/drawings and as directed by PMC/Employer.

-

-

-

20

-

-

20

-

-

20

-

-

30

-

-

20

-

-

20

-

-

30

-

-

... More
Supply & Installation Structural support for manifold along with fabrication of cylinder support stand,angle, channel and pipe support along with fittings to make system complete

100

-

-

... More
Supply installation Testing & commissioning of UL/ VDS/FM Listed Nitrogen Pilot Cylinder for actuation of main cylinder in case the main cylinders are kept within the risk room / multiple bank to be operated with one actuation. The Pilot cylinder shall be PESO approved and the pilot cylinder valve also needs to be PESO approved.

3

-

-

... More
Supply, Installation and commissioning of UL/ VDS/ FM listed Single zone gas release panel facility to connect manual abort/ release switch. The panel shall provide potential free contacts for first knock, second knock, trouble/ fault/ VDS status. The Panel shall be including 2 Core x 1.5 mm², Multistranded AT Copper, ZHFR Armoured cable, RED in Colour. The cable shall be laid on surface with GI saddle-spacers every 0.3 meters. Complete with GI Junction Box, lugs, cable compression glands, cable tags and Ferruling, required fittings, jointing, bracing, clamping, fastening.The panel shall be complete red color housing , monitored power supply unit, battery charger and batteries as per specification/drawings and as directed by PMC/Employer .

1

-

-

... More
Supply, installation, testing and commissioning of Manual abort stations, shall be fitted with transparent hinged covers to avoid possibility of accidental operation. The abort will be monitored simultaneously by the fire alarm or BMS system as per specification/drawings and as directed by PMC/Employer .

1

-

-

... More
Supply installation, testing and commissioning of Manual release station , shall be fitted with transparent hinged covers to avoid possibility of accidental operations. The Release switch shall be monitored simultaneously by the fire alarm or BMS system as per specification/drawings and as directed by PMC/Employer .

1

-

-

... More
Towards Conducting Room Integrity Test : Door Fan test to meet the Requirements of the NFPA 2001, and predicting the efficacy of the Protected Area Enclosure from the perspective of Fire Suppression as per specification/drawings and as directed by PMC/Employer.

1

-

-

... More
Supply, installation, testing and commissioning of Conventional Smoke Detector suitably mounted on ceiling with MS juction box / false ceiling using fixing accessories like screws, plug, clamps, etc., as per standard methods and as directed by the PMC/ EMployer.

4

-

-

... More
Supply, installation, testing and commissioning of Electronic Hooter / Sounder providing on wall using fixing accessories like screws, plug, clamps and etc., as per standard methods and as directed by the PMC/ EMployer.

2

-

-

... More
Supply, laying, termination, testing and Commissioning of armoured FRLS control wires 2C x 2.5 sqmm made of PVC insulated copper conductor, PVC sheathed,confirming to IS 1554 etc. shall include all fittings, jointing, glands, lugs, bracing, clamping, fastening, chasing, termination and testing. complete as per specification/drawings and as directed by PMC/Employer. For Detectors & Hooters

40

-

-

... More
FIRE EXTINGUISHER SYSTEM

-

-

-

... More
Supply, lnstallation, testing and Commissioning of Carbon Dioxide (CO2) type Fire Extinguisher conforming to IS:15683, with ISI marked approved fitted with required accessories including wall suspension brackets as per specification/drawings and as directed by PMC/Employer .

-

-

-

... More
4.5 kg.

349

-

-

... More
Supply, lnstallation, testing and Commissioning of Water CO2 Stored Pressure Type 9 litres capacity Fire Extinguisher as per new IS 15683 complete with control valve, gun metal cap, pressure gauge, operation sticker, discharge hose, wall mounting bracket, safety clip, etc., as directed by the PMC/Employer .

36

-

-

... More
Supply, lnstallation, testing and Commissioning of ABC Dry Chemical powder Mono-Ammonium Phosphate (MAP)-90% (stored pressure) type - 6 kg Fire Extinguisher conforming to IS:15683, with ISI marked approved fitted with required accessories including wall suspension brackets as per specification/drawings and as directed by PMC/Employer .

243

-

-

... More
Supply, lnstallation, testing and Commissioning of ABC Dry Chemical powder Mono-Ammonium Phosphate (MAP)-90% (stored pressure) type - 9 kg Fire Extinguisher with all required accessories, conforming to IS:15683, with ISI marked approved fitted with required accessories including flool mounting stand and all accessories required as per specification/drawings and as directed by PMC/Employer .

23

-

-

... More
Supply, lnstallation, testing and Commissioning of Mechanical Foam type (AFFF media) 9 Liter. cylindrical shape fire extinguisher with gas cartridge, hose and all required accessories, complete as per IS:15683 - trolley mounted type for portable use as per technical specifications with all the necessary accessories as required for complete installation shall also be included as per specification/drawings and as directed by PMC/Employer .

5

-

-

... More
Supply, lnstallation, testing and Commissioning of Mechanical Foam type (AFFF media) 45 Liter. cylindrical shape fire extinguisher with gas cartridge, hose and all required accessories, complete as per IS:15683 - trolley mounted type for portable use as per technical specifications with all the necessary accessories as required for complete installation shall also be included as per specification/drawings and as directed by PMC/Employer .

9

-

-

... More
Supply, Installation of Floor mounted bucket stand with GI buckets to hand 4 nos. of 9 ltrs buckets sand filled (as per IS: 2546). The stand shall be 5'(L) x 3'(H) x 2"(W) made out of 30 x 300 x4mm MS angle frame duly coated with 2 coats of red oxide primer & 2 coats of red finish paint as per specification/drawings and as directed by PMC/Employer.

21

-

-

... More
Supply, lnstallation, testing and Commissioning of ISI Marked Wet Chemical Stored Pressure Type Fire Extinguisher, Capacity 2L, Fire rating 5F, Deep drawn cylinder body with Metal Skirt, Squeeze Grip CE marked Valve made of forged brass with nickel chromium plating and Stainless Steel Carrying and Operating Handles, In built pressure release device & NRV at pressure gauge mounting port, Polyvinyl Siphon Tube, Stainless Steel safety pin,Brass Nickel Chrome plated nozzle, High Quality Vinyl label, QR code for product traceability, Testing and Inspection - As per IS 15683:2018.( For Kitchen & pantry)

16

-

-

... More
Supply, lnstallation, testing and Commissioning of 2 kg Fire Extinguisher UL listed FE-36 (HFC-236 fa) gas Electrically nonconductive, non corrosive, colorless and non-residual clean agent Suitable for Class A, B, C, and electrical fires approved with US EPA (Environmental Protection Agency), listing under USA Signification New Alternative Policy ( SNAP) & also approved by (Environmental Protection Agency) listing under USA Signification New Alternative Policy SNAP) & also approved by UL, compliant with ASTM -D6541-11. low toxicity, also its replacement for Halon 1211, Halon 1201. Controllable discharge mechanism with EPDM Discharge Hose with Specially designed Unique Nozzle, UGTS Pressure Gauge, Body Construction Deep Drawn with MIG Welding technology, External Pure polyester and Internal Epoxy polyester powder coated, Brass forged CE marked valves with safety pressure release mechanism, safety Pin is of SS material, and Welding Procedure approved by TPI with 6 G certification. Fire Class 1A:21B rating as per IS 15683 and ISI MARK.

30

-

-

... More
Supply, lnstallation, testing and Commissioning of FE36 Automatic ceiling Mounted Clean agent Extinguisher with Ceiling mount accessories including nozzle(57 deg), pressure guage. ISI approved

-

-

-

89

-

-

... More
ELECTRICAL PANELS, STARTER PANELS, CABLES, TERMINATIONS

-

-

-

... More
FIRE FIGHTING PANEL-1

-

-

-

... More
Fabrication, supply, Installation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalized with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering , MS steel channels for panel mounting etc. complete in all respect, suitable for main fire pump, pressurization pump & set complete as per specification with following incoming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 55 bottom entry as required. Operation Logic shall be as per specification/drawings and as directed by PMC/Employer. LOCATION: PUMP ROOM

-

-

-

... More
630A, 50kA 4 Pole MCCB, microproccessor based Ics=100% Icu Rating - 2 sets Each Breaker shall consists of following, Digital Voltmeter 0-500V Digital Ammeter (0-630 A) & CTs etc. LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 800Amps Auto changeover with Electrical interlock shall be provided between two incomers. All required hardwares, contactors, auxiliary relay ,etc shall be considered. Outgoings (Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps) Main Fire Hydrant/Sprinkler Pump 250Amp, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Soft starter suitable for 110KW rated pump with overload protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.. - 2 Numer & 1 number spare Jockey Pump for Hydrant/Sprinkler Pump 63 Amp, 25kA TPN MCCB, Ics=100% Icu, with Suitable HP fully automatic Star/Delta starter suitable for rated pump with overload protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. - 2 Numbers & 1 Number Spare LOCATION: PUMP ROOM

1

-

-

... More
DIESEL ENGINE CONTROL Control for diesel engine comprising - Automatic/Manual selector switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode. Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitable for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0-20 A DC Ammeter (digital) All standard relays and accessories for automatic operation of diesel engine System Controller Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification. Diesel Engine control panel shall be capable of controlling 1 number of diesel pump.-1 set LOCATION: PUMP ROOM

1

-

-

... More
STARTER ISOLATOR PANELS

-

-

-

... More
Design, supply, installation, testing and commissioning of local starter panels with (IP65) enclosure made up of Double CRCA sheet steel of 2/4 mm thick for frame work and covers with hinged lockable doors , on surface/ recess suitable for mounting 11kW Star Delta Starter for Booster pumps complete with connections, etc. as required. The enclosure shall withstand 200 deg for 2 hours. The local starter panel shall be complete with all necessary Power & control circuit breakers like MPCB with inbuilt thermal overload relay, Auxiliary relays, Contactors, with E/F Protection contactors, SPPR, Start/Stop push buttons, On/Off/Trip indication lamps, auto/manual selector switches, terminal blocks, Analog Ammeter with CT etc and must have arrangement to receive BMS & fire signal input. All protective equipment /component rating shall be as per type 2 coordination chart. The panel suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection shall be of min IP65 for outdoor applications. All hardware required for mounting of local starter panel in wall/floor shall be included in the local control panel itself. LOCATION: TERRACE FLOOR

1

-

-

... More
MV CABLE AND CABLE LAYING

-

-

-

... More
“Supply, loading, transportation unloading and storages at site , shifting from storage place to site, laying, installation, commissioning of following sizes of Stranded Annealed Bare Copper Conductor , 950° for 3 hours Mica Tape Wrapped, Xlpe Insulation, Cores Laid up together, Fiber Glass Tape Wrapped, LSZH Inner Sheathed, GI Wire Strip Armoured, LSZH Outer sheathed Fire Survival Cables of 1.1 KV grade conforming to BS 7846 amended up to date, and cable should pass circuit integrity test as per BS 6387. LOCATION: PUMP ROOM & TERRACE

-

-

-

... More
240 Sq.mm x 3.0C Cu. Fire Survival Cable

50

-

-

... More
185 Sq.mm x 3.0C Cu. Fire Survival Cable

220

-

-

... More
50 Sq.mm x 3.0C Cu. Fire Survival Cable

60

-

-

... More
25 Sq.mm x 3C Cu. Fire Survival Cable

320

-

-

... More
MV CABLE TERMINATION

-

-

-

... More
Supplying and making Flame Proof end termination with brass double compression Flame Proof gland and Copper lugs for following sizes of XLPE insulated and PVC sheathed Copper conductor cable of 1.1 KV grade as required

-

-

-

... More
3c 240Sqmm

2

-

-

... More
3c 185Sqmm

4

-

-

... More
3C 50 sqmm

2

-

-

... More
3C 25 sqmm

6

-

-

... More
CABLE TRAYS

-

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanized Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. LOCATION: PUMP ROOM & TERRACE

-

-

-

... More
GI Hot Dip 16 SWG Cable Tray with 150mm width and 50mm height

100

-

-

... More
GI Hot Dip 16 SWG Cable Tray with 300mm width and 50mm height

50

-

-

... More
GI Hot Dip 16 SWG Cable Tray with 600mm width and 50mm height

110

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanized Iron cable tray "bends" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. LOCATION: PUMP ROOM & TERRACE

-

-

-

... More
150 mm width X 50 mm depth X 1.6 mm thickness

3

-

-

... More
300 mm width X 50 mm depth X 1.6 mm thickness

2

-

-

... More
600 mm width X 50 mm depth X 2.0 mm thickness

4

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanized Iron cable tray "Tee" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. LOCATION: PUMP ROOM & TERRACE

-

-

-

... More
150 mm width X 50 mm depth X 1.6 mm thickness

3

-

-

... More
300 mm width X 50 mm depth X 1.6 mm thickness

2

-

-

... More
600 mm width X 50 mm depth X 2.0 mm thickness

4

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanized Iron cable tray "Cross member"(galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required. LOCATION: PUMP ROOM & TERRACE

-

-

-

... More
150 mm width X 50 mm depth X 1.6 mm thickness

3

-

-

... More
300 mm width X 50 mm depth X 1.6 mm thickness

2

-

-

... More
600 mm width X 50 mm depth X 2.0 mm thickness

4

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanized Iron cable tray "Reducer"(galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required. LOCATION: PUMP ROOM & TERRACE

-

-

-

... More
150 mm width X 50 mm depth X 1.6 mm thickness

3

-

-

... More
300 mm width X 50 mm depth X 1.6 mm thickness

2

-

-

... More
600 mm width X 50 mm depth X 2.0 mm thickness

4

-

-

... More
STATUTORY APPROVAL

-

-

-

... More
Taking STATUTORY APPROVALS (Liasioning) of all fire fighting system from local fire authority and any other relevant statutory authority at initial & various other stages of works, including preparation of report / drawings as per fire authority. Contractor shall include cost of all liaison works which are not explicitly mentioned above but are mandatory to have fire authority approval (any statutory charges will be reimbursed as per actual upon production of the invoice / challan).

1

-

-

... More
MISCELLANEOUS

-

-

-

... More
Supply, Installation, Testing & Commissioning of Triple Spur Gear, Top & bottom hook with safety latch hand hoist, 3 Ton capacity, Swivel for Top & Bottom block Chain pulley block (12.0 m lift) with long travel rail track (40 mm sq. bar), moving or cross girder, all three motions electrically operated by with all accessories as complete The chain blocks should be tested to a proof load of 1.5 times the working load limit. It should be light weight & sturdy for ease of handling. Chain pulley blocks must confirm to IS 3832 and Safety approval from reputed national / international agencies along with test certificate. LOCATION: PUMP ROOM

1

-

-

... More
Supply, Installation, Testing and commissioning of Fire stop mortar system with minimum 2 hours fire rating when tested in accordance with UL 1479/ASTM-E 814 standards, for horizontal openings in floors or slabs after passing service lines like Metal/Plastic Pipes, Duct & Cable trays with combustibel/Non Combustible insulations. The mortar shall be a light weight cementitious product and shall carry test certificate in accordance with IEC 60068-2-57:1999-11 (Environmental Testing) as per Part 2-57: Test for Vibration-Time-history method for seismic zone 3. The product shall be age tested as per Dafstb and DIBT standards. The product shall carry test certificate for mold resistance rating of 0 as determined by ASTM G21-96. The system shall be UL listed & classified and product shall bear the UL and FM approval logo on the packing. A firestop submittal shall be produced by manufacturer , in accordance with approved passive fire protection method statement, for technical approval. Firestop installation shall be done by supplier Accredited Firestop Speciality Contractor or by certified installers inline with UL system test certificates. Firestop Speciality Contractor needs to submitt work completition certificate along with installation report with supplier warranty certificate for periodic inspection & maintenance purpose. The gaps around combustible penetrants like plastic pipes or ducts with insulation shall be sealed with an appropriate material as recommended by the supplier. LOCATION: ALL FLOORS FHC, PHE SHAFT, ELECTRICAL AND ELV SHAFTS & OPENINGS

356

-

-

... More
Supply, Installation, Testing and commissioning of High performance Intumescent and Acrylic Firestop sealant that helps protect combustible penetrations for up to 2 hours fire rating in accordance to UL 1479 (American) standards. Surface burning characteristics according UL 723 (ASTM E84-96). Flame spread index 0 and smoke development index 5. Movement capability approx.. 5% (ISO 11600) and the average volume shrinkage is 24% according ASTM C1241meeting LEED requirements for indoor environmental quality credit (4.1 and 4.2) with a VOC content of 9 g/l. product should also Seismic tested on mechanical performance, smoke and fire-ratings. LOCATION: ALL FLOORS FHC, PHE SHAFT, ELECTRICAL AND ELV SHAFTS & OPENINGS

99

-

-

... More
Providing & Fixing First Aid Box complete with all First Aid Medicines

2

-

-

... More
PLUMBING SYSTEM WORK

-

-

-

... More
PUMPS AND ACCESSORIES

-

-

-

... More
Supply, installation, testing and commissioning of Compact Self Contained Skid Mounted Transfer Pump for UGT, OHT Filling SS vertical multistage centrifugal pump. Each pump shall have TEFC 2900 RPM three phase electric motor of IE-3 efficiency operating at 50 Hz ± 3%, 415V± 10% along with base frame, coupling guard, foundation bolts etc. complete set as per relevant IS . The pump shall have SS 304 casing, cast Iron head, C.I base, SS 316 Shaft, bronze/ SS 316 Impeller , SS 304 Intermediate chamber. Pump shall be provided with cartridge type mechanical seal. The pump shall be suitable for auto/ manual operation with pressure gauge in the discharge line with all necessary accessories, as per specification/drawings and as directed by PMC/Employer.’’ Contractor shall provide necessary test certificates, type test certificates, performance curves and NPSH curves of the pumps from the manufacturer prior to procurement and get it approved from the PMC/Employer. The contractor shall provide facilities to the PMC/Employer for inspection of equipment during manufacturing and also to witness various tests at the manufacturer’s works without any cost to the PMC/Employer

-

-

-

... More
a)The pump shall be selected for performance at best efficiency point. However, the pump selection shall be suitable for performance with set point @ + 20% of the rated head. b)Precharged diaphragm pressure vessel with food grade membrane, charging connection, connected to outlet header with necessary flanges, gaskets, isolating valves, nuts/bolts etc. complete. c)Set of accessories such as pressure switches, inter connecting power and control cabling etc. complete. d)Accessories like NRVs isolating valves, SS-304 (non-Magnetic) / MS CED Coating suction and delivery header, pressure gauge, MS base frame (Synthetic enamel painted over a coat of primer)

-

-

-

... More
Each Pump sets shall be provided with dedicated Starter & Control panel, earthing and (power & control) cabling, cable trays as per drawing and site condition between control panel and pump., terminations with necessary lugs and glands, etc. The panel shall be of min. IP54 for indoor duty. STARTER PANEL fabricated out of 2mm thick CRCA sheet with hinged lockable doors, complete with all required accessories,etc. with keypad and pressure display screen The local starter panel shall be complete with all necessary Power & control circuit breakers, contactors, SPPR, Start/Stop push buttons, On/Off/Trip indication lamps, auto/manual selector switches, Overload relay, Auxiliary relays, terminal blocks, Analog AmMetre with CT etc. and must have arrangement to receive BMS. MCB shall be provided for all incomer and MPCB shall be provided for all out going feeders. All protective equipment /component rating shall be as per type 2 coordination chart. Operation Logic shall be as per specification All hardwares required for mounting of local starter panel in wall/floor shall be included in the local control panel itself. The panel shall be provided with proper changeover arrangement for dual incomers. Single point BMS connectivity and dual power feeders shall be provided by others. Number of outgoing feeders shall be as per system requirement. All power cables shall be XLPE copper cable of adequate size. All control cables shall be PVC copper cable.

-

-

-

... More
In addition to the electronic pump controller, the control cabinet shall including pressure transmitter, float switches and the control circuit, control relays for alarm functions and fuses. Panel shall be compatible to BMS with ethernet provision. Pumps shall have dry run protection & high/low level alarm. It shall include cables and accessories such as PLC, auto/ manual mode operation complete as specified and directed by PMC/Employer. Set of accessories such as pressure switches, pressure transducers, inter connecting power and control cabling etc. complete. Pump control panel The pump control panel shall be designed and manufactured by the pump manufacturer to ensure no split responsibility and assured serviceability from one supplier. If the control panel is procured from a third party it shall be certified by the pump manufacturer for smooth functioning and assured serviceability. The pump control panel must include following features: o An individual display showing discharge pressure. o An individual display showing the selected set point. o One button to operate each pump in either Auto or Off o A locking function of the buttons providing protection against faulty use. o A LED indicating System Alarm. o A LED indicating System Operation. o A LED indicating the individual pump status. o A LED indicating Water Shortage o A LED indicating the status of the primary sensor o A reset button to reset faults.

-

-

-

... More
Flow for Each pump :7 LPS Nos. of Pumps : 1 Set : 3 (2W+1S) Head : 110 M each Purpose: For OHT filling (DOMESTIC) LOCATION: PUMP ROOM

1

-

-

... More
Flow for Each pump :5 LPS Nos. of Pumps : 1 Set : 3 (2W+1S) Head : 110 M each Purpose: For OHT filling (FLUSHING) LOCATION: PUMP ROOM

1

-

-

... More
Flow for Each pump :5 LPS Nos. of Pumps : 1 Set : 3 (2W+1S) Head : 110 M each Purpose: For OHT filling (HVAC Make Up) LOCATION: PUMP ROOM

1

-

-

... More
Flow for Each pump :2 LPS Nos. of Pumps : 1 Set : 2 (1W+1S) Head : 15 M each Purpose: For OHT filling (GUARD BLOCK DOMESTIC) LOCATION: PUMP ROOM

1

-

-

... More
Flow for Each pump :3 LPS with 12 Hours pumping Nos. of Pumps : 1 Set : 2 (1W+1S) Head : 15 M each Purpose: For UGT filling (HVAC MAKEUP & DOMESTIC WATER MIXING) LOCATION: PUMP ROOM

1

-

-

... More
Flow for Each pump :8 LPS Nos. of Pumps : 1 Set : 3 (2W+1Assist) Head : 30 M each Purpose: For External Discharge (Rainwater) LOCATION: PUMP ROOM

1

-

-

... More
Flow for Each pump :3.6 LPS Nos. of Pumps : 1 Set : 2 (1W+1S) Head : 36 M each Purpose: For landscape Irrigation LOCATION: PUMP ROOM

1

-

-

... More
Flow for Each pump :5 LPS Nos. of Pumps : 1 Set : 2 (1W+1S) Head : 25 M each Purpose: For Rain water Filtration & Backwash LOCATION: PUMP ROOM

2

-

-

... More
Flow for Each pump :3 LPS with 12 Hours pumping Nos. of Pumps : 1 Set : 2 (1W+1S) Head : 15 M each Purpose: For UGT filling (FLUSHING) LOCATION: STP

1

-

-

... More
Flow for Each pump :3 LPS with 12 Hours pumping Nos. of Pumps : 1 Set : 2 (1W+1S) Head : 15 M each Purpose: For UGT filling (HVAC MAKEUP) LOCATION: STP

1

-

-

... More
Flow for Each pump :2 LPS with 12 Hours pumping Nos. of Pumps : 1 Set : 2 (1W+1S) Head : 15 M each Purpose: For UGT filling (IRRIGATION) LOCATION: STP

1

-

-

... More
Supply, installation, testing and commissioning of compact self contained skid mounted hydropneumatic system with VFD of IE-3 efficiency as follows: a)Vertical, In-Line, multistage, centrifugal pumps with SS-304 casing and impeller and SS-316 shaft, CI base & head TEFC motor (with mechanical seal) b)Vendor to submit performance curves and technical catalog of the proposed model for review & information during detailing) c)The pump shall be selected for performance at best efficiency point. However, the pump selection shall be suitable for performance with set point @ + 20% of the rated head. d)External Pump mounted or wall mounted microprocessor PID controller and frequency inverter integrated in a single body or as separate components with pressure sensor transmitter minimum two lined LCD display, diodes to indicate pump ready, pump running and fault and capable to communicate with other controllers following MODBUS-RTU or BACNET Class-2 protocall through RS485 port. System should be capable to compensate for frictional losses at lower flows. All alarms should be displayed in the controller. System should be equipped with dry running protection. e)Complete (Skid mounted wall mounted / floor mounted) electrical control panel with IP 55 Protection bottom entry comprising of all accessories such as PLCs, pressure switches, pressure transducers, control wiring and any other necessary imports etc. (List to be provided by the vendor). Dedicated panels to be provided for each pump sets. f)Precharged diaphragm pressure vessel with food grade membrane, charging connection, connected to outlet header with necessary flanges, gaskets, isolating valves, nuts / bolts etc. complete. g)Set of accessories such as pressure switches, pressure transducers, inter connecting power and control cabling etc. complete h)Accessories like NRVs, strainer, isolating valves, SS-304 (non-Magnetic) suction and delivery header, pressure gauge, MS base frame (Synthetic enamel painted over a coat of primer) etc. complete as per PMC/Employer.

-

-

-

... More
Hydropneumatic System as described above with Flow rate : 5 LPS Head : 20.0 Mts Required for : Domestic Booster Pumps (1W + 1S) LOCATION: TERRACE

1

-

-

... More
Hydropneumatic System as described above with Flow rate : 6 LPS Head : 20.0 Mts Required for : Flushing Booster Pumps (1W + 1S) LOCATION: TERRACE

1

-

-

... More
Submersible Centrifugal Non-clog Drainage Pumps Supply, installation, testing and commissioning of submersible pumps As Follows: Supply, installation, testing and commissioning of continuous duty Submersible Centrifugal non-clogging or vortex type drainage pumps complete with 3 phase motor with all necessary protection and mechanical seal as per manufacturer standard etc. Pumps set shall have auto coupling assembly. The installation shall be complete with all necessary indigenous accessories as required to complete the installation with pressure gauge in the discharge line as per specification/drawings and as directed by PMC/Employer. Contractor shall provide pump lifting arrangement shall comprise of MS galvanized guide bar & MS assembly with SS 304 chain with shakle suitable for 2 Nos. submersible drainage pumps in a sump of overall depth not more than 2.0 m,

-

-

-

... More
Each pump sets shall be provided with Local starter panels of IP55 rating fabricated out of 2mm thick CRCA sheet with hinged lockable doors, complete with all required starters of DOL starter. Pump shall be provided with separate skid mounted electrical panel of 415V +10%, 50 Hz, 3 Phase AC supply, for power supply distribution and control for equipment listed below with all necessary power & control circuit breakers, contactors, SPPR, start-stop push button, on-off trip indication lamp, overload relay, auxiliary relay, auto/manual selector switches, earthing and internal power & control cabling, terminations with necessary lugs and glands, etc. With Switchgears as per detail given below, a) 1 Numbers of Incomer MCCB feeder with thermal magnetic release of suitable electrical rating. Earth fault release shall be provided for both incomers. b) 2 numbers of outgoing feeders with DOL starters of suitable rating for 2 number of pumps (1W+1Standby). All protective equipment rating shall be as per type-2 coordination chart. Outgoing feeders shall be provided with MPCB with inbuilt overload protection. All outgoing shall be provided with earth fault protection.

-

-

-

... More
All hardwares required for mounting of panel in wall/floor shall be included in panel cost itself. All power cables shall be armoured ,XLPE, coper cable of adequate size. All control cables shall be armoured PVC copper cable. Minimum of 2.5Sq.mm cable shall be used for power and control cable.

-

-

-

... More
Note:- Power supply at 1 Number incomer in the panel and single point BMS connectivity shall be done by electrical contractor. The pump panel shall have RS-485/Modbus/BACnet over IP/ BACnet over MSTP port to integrate with Building Management System without any external hardware/converter requirement. Technical integration details shall be provided by Plumbing contractor to BMS contractor and ensure proper integration is done. Operation Logic shall be as per specification.

-

-

-

... More
Control panel shall comprise of level sensor and pumps shall have dry run protection with high/ low level alarm. Pumps shall be supplied with 3 Nos. float switches and electrical control panels with cables. Each pump shall have provision for auto/ manual operation in the control panel. Panel shall be compatible to BMS with ethernet provision. Panel shall have provision to run all pump simultaneously at flooding condition. Pump control panel The pump control panel shall be designed and manufactured by the pump manufacturer to ensure no split responsibility and assured serviceability from one supplier. If the control panel is procured from a third party it shall be certified by the pump manufacturer for smooth functioning and assured serviceability.

-

-

-

... More
1 Set : (1 Working + 1 Standby) Flow rate: 5 LPS each Head: 25 Mts Solid Handling: 25 MM Purpose: Pump room drainage MOC: CI -Body, C.I impeller & SS shaft - (420 or 431) LOCATION: PUMP ROOM SUMP PIT

1

-

-

... More
Providing, fixing, jointing, testing and commissioning in position Class "C" GI pipe work (Approx 10M length for each set) for all Sump Pump discharge line with common header complete with all fittings like butterfly valve, NRV, elbow, tee, reducer, flange, union etc. complete, conforming to IS:1239 (Part 1) for pipes and IS : 1879 (Part 1 to 10) for fittings including fixing in wall / ceiling / floor level, supported by galvanized clamps, hangers, vertical pipe support etc. as per specification/drawings and as directed by PMC/Employer. LOCATION: PUMP ROOM SUMP PIT

1

-

-

... More
Supplying and fixing Grundfos make Solo lift-2, C3 waste water transfer pumpset or equivalent with automatic control float, including tank, isolation valve, NRV, control panel including testing, commissioning complete. (To pump Waste water from Guard block Wash basin to main sewer ). Flow rate: 1LPS Head: 7m - 10m LOCATION: GUARD BLOCK TOILET

2

-

-

... More
Supplying and fixing Grundfos make Solo lift-2, WC1 or WC3 black water transfer pumpset or equivalent with automatic control float, including tank, isolation valve, NRV, control panel including testing, commissioning complete. (To pump black water from WC to main header at basement-01 from Guard block). Flow rate: 1LPS Head: 7m - 10m LOCATION: GUARD BLOCK TOILET

2

-

-

... More
AUTOMATIC LEVEL CONTROL SYSTEM

-

-

-

... More
Supply, installation, testing and commissioning of Automatic Level Control system including level indicator with BMS compatibility consisting of following items 1.1) Water Level Float Switch single sensor (low /high) with NO/NC contacts 1.2) Control Box 24V, 1.3) Necessary cabling approx 100 metres ie (From float switches to control panel, control panel to valves and control panel to pump & main power supply to control panel) 1.4) On-Off Type Motorized Butterfly Valve (1 Numbers of 100 mm dia) and other neccessary accessories to make system complete as per specification/drawings and as directed by PMC/Employer. LOCATION: ( FOR OHT - FIRE, DOMESTIC WATER). AT TERRACE

4

-

-

... More
Supply, installation, testing and commissioning of Automatic Level Control system including level indicator with BMS compatibility consisting of following items 1.1) Water Level Float Switch single sensor (low /high) with NO/NC contacts 1.2) Control Box 24V,approx 100 metres ie (From float switches (UGT & OHT) to control panel, control panel to valves and control panel to pump & main power supply to control panel) 1.3) On-Off Type Motorized Butterfly Valve (1 Numbers of 80mm dia), and other neccessary accessories to make system complete as per specification/drawings and as directed by PMC/Employer. LOCATION: ( FOR OHT - FLUSHING & HVAC MAKEUP WATER). AT TERRACE

4

-

-

... More
Providing, fixing, jointing, testing and commissioning of Automatic Level Control system including level indicator with BMS compatibility consisting of following items 1.1) Water Level Float Switch single sensor (low /high) with NO/NC contacts. 1.2) Control Box 24V , 1.3) Necessary cabling approx 100 metres i.e (From float switch to control panel, panel to valves & main power supply to control panel) 1.4) On-Off Type Motorized Butterfly Valve (3 Numbers of 200 mm dia ), CI.Body with PTFE Seat and other neccessary accessories to make system complete as per specification/drawings and as directed by PMC/Employer. LOCATION: FOR TERRACE RAIN WATER DOWN TAKE TANK FILLING & BYPASS SYSTEM AT PUMP ROOM

1

-

-

... More
Supply, installation, testing and commissioning of Automatic Level Control system including level indicator with BMS compatibility consisting of following items 1.1) Water Level Float Switch single sensor (low /high) with NO/NC contacts 1.2) Control Box 24V, 1.3) Necessary cabling approx 75 metres ie (From float switches (UGT & OHT) to control panel, control panel to valves and control panel to pump & main power supply to control panel) 1.4) On-Off Type Solenoid valve (1 Numbers of 50mm dia) and other neccessary accessories to make system complete as per specification/drawings and as directed by PMC/Employer. LOCATION: (FOR OHT - DOMESTIC WATER) AT GUARD BLOCK

2

-

-

... More
Supply, installation, testing and commissioning of Automatic Level Control system including level indicator with BMS compatibility consisting of following items 1.1) Water Level Float Switch single sensor (low /high) with NO/NC contacts 1.2) Control Box 24V,approx 150 metres ie (From float switches (UGT & OHT) to control panel, control panel to valves and control panel to pump & main power supply to control panel) 1.3) On-Off Type Motorized Butterfly Valve (1 Numbers of 80mm dia), and other neccessary accessories to make system complete as per specification/drawings and as directed by PMC/Employer. LOCATION: ( FOR UGT - IRRIGATION WATER). AT UGT PUMP ROOM

1

-

-

... More
Supply, installation, testing and commissioning of Automatic Level Control system including level indicator with BMS compatibility consisting of following items 1.1) Water Level Float Switch single sensor (low /high) with NO/NC contacts 1.2) Control Box 24V,approx 150 metres ie (From float switches (UGT & OHT) to control panel, control panel to valves and control panel to pump & main power supply to control panel) 1.3) On-Off Type Motorized Butterfly Valve (1 Numbers of 100 mm dia), and other neccessary accessories to make system complete as per specification/drawings and as directed by PMC/Employer. LOCATION: ( FOR UGT - FLUSHING & HVAC MAKEUP WATER). AT UGT PUMP ROOM

4

-

-

... More
Supply, installation, testing and commissioning of Automatic Level Control system including level indicator with BMS compatibility consisting of following items 1.1) Water Level Float Switch single sensor (low /high) with NO/NC contacts 1.2) Control Box 24V,approx 25 metres ie (From float switches (UGT & OHT) to control panel, control panel to valves and control panel to pump & main power supply to control panel) 1.3) On-Off Type Motorized Butterfly Valve (1 Numbers of 200mm dia), and other neccessary accessories to make system complete as per specification/drawings and as directed by PMC/Employer. LOCATION: ( FOR UGT - FIRE & DOMESTIC WATER) AT UGT PUMP ROOM

4

-

-

... More
INTERNAL & EXTERNAL WATER SUPPLY

-

-

-

... More
Supplying, Installing, Testing and Commissioning of uPVC scheduled 80 pipe conforming to ASTM D 1785 and fitting scheduled 80 conforming to D 2567, The fittings and specials such as tees, elbows, couplers, bends, enlargers, flanges, unions, connectors, adapters etc. with uPVC brass threaded combination/ transition specials such as male adapters, brass threaded female adapters, brass FPT Tee, Brass FPT elbow, etc. where connection with metal is to be made including necessary drilling holes, chasing walls and making the same good in cement martor 1:1, restore the same to original condition neatly as directed by the PMC/Employer. Joints to be made with uPVC solvent cement shall be as per ASTM D 2564. Manufacturer's recommendation shall be followed for installation of pipe & jointing of uPVC pipework. NOTE: All Water supply pipe headers/riser shall be worded indicating the direction of the flow and its purpose such as "TO RISER NO.1/ DOWNTAKE /ZONE" as per PMC/Employer etc. LOCATION: DOMESTIC AND FLUSHING PIPING INSIDE SHAFT, OHT FILLING.

-

-

-

... More
25 mm dia

204

-

-

... More
32 mm dia

317

-

-

... More
40 mm dia

332

-

-

... More
50 mm dia

383

-

-

... More
65 mm dia

419

-

-

... More
80 mm dia

951

-

-

... More
100 mm dia

512

-

-

... More
150 mm dia

50

-

-

... More
Providing, laying, testing and commissioning of Centrifugally cast (spun) Ductile Iron pipe with tyton jointed class "K9" confirming to IS 8329 with class K12 fittings confirming to IS 9523 including metallic zinc coating and finished layer of bituminous paints, fittings, elbows, nuts, bolts, gaskets etc., Fixing/supporting the pipes & fittings at wall/ceiling level supported by galvanized clamps, by fastener, hangers etc, NOTE: 1.All Water supply pipe headers/riser shall be worded indicating the direction of the flow and its purpose such as "TO RISER NO.1/ DOWNTAKE /ZONE" as per PMC/Employer etc. 2. Laying and Jointing of DI pipes and fittings shall be done as per IS: 12288 and manufacturer’s recommendations. 3. M.S to D.I Flanged connection will confirm to the clause 6.2 of IS: 8329. LOCATION: UGT DOMESTIC WATER FILLING FROM MUNICIPAL WITHIN PUMP ROOM

-

-

-

... More
100 mm dia

25

-

-

... More
150mm dia

25

-

-

... More
200 mm dia

25

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes SDR -11,having thermal stability for cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step ASTM F441 with only CPVC solvent cement conforming to ASTM F-493 and the cost of cutting chases/holes and making good the same including testing of joints complete as per direction of PMC/Employer. Concealed work, including cutting chases and making good the walls etc. NOTE: Pipe union shall be provided in the distribution line for ease of maintenance. LOCATION: DOMESTIC AND FLUSHING PIPING FOR INTERNAL TOILETS, KITCHEN, PANTRY, AHU ROOM ETC.,

-

-

-

133

-

-

133

-

-

... More
25 mm

8515

-

-

... More
32 mm

1789

-

-

... More
40 mm

332

-

-

... More
50 mm

92

-

-

... More
Providing, fixing, testing and commissioning of Copper Tubes conforming to EN 1057 complete with End Feed Type Capillary Fittings in accordance with EN 1254-1 such as sockets, bends, elbows, tees, reducers, unions. All threaded adaptors shall be of DZR Brass material. Pipe and fittings shall be joined using brazing techniques. To be supplied with necessary adapters from other piping material GI/ pastics to Copper Tubing to CP fittings, jointing, sundries,cutting holes in walls/floors/slabs & making good including wraping with ploythene sheet tape etc. complete. Exposed pipes to be insulated (seprate item) painting of legends with direction arrow on insulation with all necessary accessories, as per specification/drawings and as directed by PMC/Employer. Direct contact of copper pipe to galvanized support shall be avoided by inserting approved type of filler material. LOCATION: KITCHEN EXPOSED HOT WATER PIPES

-

-

-

... More
15 mm dia

16

-

-

... More
22 mm dia

31

-

-

... More
28 mm dia

102

-

-

... More
35 mm dia

51

-

-

... More
42 mm dia

51

-

-

... More
54 mm dia

51

-

-

... More
Providing, fixing, testing and commissioning of Copper Tubes conforming to EN 1057 complete with End Feed Type Capillary Fittings in accordance with EN 1254-1 such as sockets, bends, elbows, tees, reducers, unions. All threaded adaptors shall be of DZR Brass material. Pipe and fittings shall be joined using brazing techniques. To be supplied with necessary adapters from other piping material GI/ pastics to Copper Tubing to CP fittings, jointing, sundries,cutting holes in walls/floors/slabs, Chisel in walls & making good including wraping with ploythene sheet tape etc. complete with all necessary accessories, as per specification/drawings and as directed by PMC/Employer. (internal work ). LOCATION: KITCHEN HOT WATER PIPES CONCEALED

-

-

-

... More
15 mm dia

16

-

-

... More
22 mm dia

31

-

-

... More
28 mm dia

31

-

-

... More
35 mm dia

16

-

-

... More
42 mm dia

16

-

-

... More
54 mm dia

16

-

-

... More
Providing, fixing, jointing, testing and commissioning of of Nitrile rubber closed cell (Thermo plastic elastomeric) insulation (insulation shall be as per class 'O' IMO fire performance ) of the following diaMetre and thickness over pipes and fittings, of minimum 45 kg / M³ density and haivng thermal conductivity 0.037W/MK or better at 20°C mean temperature, class 'O' insulation applied by suitable adhesive complete as per manufacturers specifications with necessary accessories as per specifications/drawings all complete as per directions of the PMC/Employer. Rate includes cost of all materials including fixing the insulation with the pipes with tapes or adhesives, labour charges for working at all levels, leads and heights. LOCATION: KITCHEN EXPOSED HOT WATER PIPES

-

-

-

... More
15 mm (09 mm thickness of insulation)

16

-

-

... More
22 mm (09 mm thickness of insulation)

31

-

-

... More
28 mm dia (13 mm thickness of insulation)

102

-

-

... More
35 mm dia (13 mm thickness of insulation)

51

-

-

... More
42 mm dia (13 mm thickness of insulation)

51

-

-

... More
54 mm dia (19 mm thickness of insulation)

51

-

-

... More
Providing, laying, jointing and testing in position the following ISI Marked HighDensity Poly Ethylene (HDPE-PE-100) pipes conforming to IS 4984 for water supply cut to required lengths making proper connections of required depths and suitable for pressure rating PN06. Pipe shall be cut to required lengths including all necessary fittings and specials such as bends, junctions, offsets, etc complete. Lowering, laying and jointing of HDPE pipes to be laid below ground level upto required depth of following sizes and making good the same complete as required. LOCATION: EXTERNAL ( STP TO PUMP ROOM)

-

-

-

... More
HDPE 50mm (ND) - PE100 - PN6

184

-

-

... More
HDPE 75mm (ND) - PE100 - PN6

123

-

-

... More
HDPE 90mm (ND) - PE100 - PN6

245

-

-

... More
Providing, fixing,jointing, testing and commissioning of male/ female screwed end full way lever operated forged brass ball valve of brass body with forged brass hard chrome plated ball & teflon seat, PN 10 with (threaded joints) complete as required with all necessary accessories as per specification/drawings and as directed by PMC/Employer. LOCATION: INSIDE SHAFTS FOR ISOLATION OF BRANCH PIPES

-

-

-

... More
25 mm dia

102

-

-

... More
32 mm dia

114

-

-

... More
40 mm dia

108

-

-

... More
50 mm dia

27

-

-

... More
Supplying, fixing, testing and commissioning of Butterfly valve of PN 16 rating with C.I body,Cast Bronze or Stainless Steel disc, stainless steel shaft, Either integral or Nitrile rubber seat , Nitrite/ Silicon O-ring duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required and and as directed by PMC/Employer. : LOCATION: PUMP ROOM, TERRACE AND RISERS.

-

-

-

... More
65 mm dia

20

-

-

... More
80 mm dia

23

-

-

... More
100 mm dia

41

-

-

... More
150 mm dia

11

-

-

... More
200 mm dia

3

-

-

... More
Providing, installation, testing and commissioning of Non-return valve of PN 16 rating of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required and as directed by PMC/Employer. LOCATION: PUMP ROOM, TERRACE AND HEADER

-

-

-

... More
65 mm nominal bore

3

-

-

... More
80 mm nominal bore

3

-

-

... More
100 mm nominal bore

3

-

-

... More
150 mm nominal bore

3

-

-

... More
200 mm nominal bore

2

-

-

... More
Supplying, fixing, testing & commissioning of double flanged Sluice valve of rating PN 16 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 14846 / IS 780 of following sizes as required and as directed by PMC/Employer. LOCATION: PUMP ROOM, TERRACE AND HEADER

-

-

-

... More
80 mm diaMetre

7

-

-

... More
100 mm diaMetre

3

-

-

... More
150 mm diaMetre

29

-

-

... More
200 mm diaMetre

2

-

-

... More
Providing, Fixing, Testing and commissioning of Forged Brass (Chrome Plated) Auto Air Release Valve with screwed male end as per IS 554 / BS 21 / ISO 7 required for Water Supply Risers, suitable for pressure upto 15 kg/cm². The valve body, cover should be of forged Brass (Chrome Plated) confirming to IS 6912 Gr. FLB. The Float, lock, hing, Bracket should be of Polypropylene. The seat and chamber of Forged Brass confirming to IS 6912 Gr. FLB. The spring shall be of stainless steel of Type 304. The 'O' ring should be of the Nitrile Rubber confirming to IS 5192 - 1. Suitable to fix at the top most point of the water supply network complete as per technical specifications, drawings and as directed by PMC/Employer.

-

-

-

... More
20mm NB

2

-

-

... More
25mm NB

10

-

-

... More
Providing, fixing, jointing, testing and commissioning of Pressure Reducing Valve Set for cold water supply comprising of 2 Nos Isolation valves (upto 50mm dia - Ball valve & above 50mm dia - Butterfly valve) on inlet & outlet & 01 no. Globe valve for by-pass, 01 No. Brass housing diaphragm operated Pressure Reducing Valve with flanged / screwed connection, with in-built SS 316 Filter with filter opening size 0.8 mm or lower, 1 Nos Pressure gauge on outlet, and 1 No. 15 mm dia safety valve. The complete system is tested to a pressure not less than 10 Kg/Sq.cm Including necessary pipe & fittings; i.e. flanges/ unions, nuts, bolts and washers complete as required. (installed on cold water make up line to Hot water mixing tank) with all necessary accessories, as per specification/drawings and as directed by PMC/Employer. Note: The PRV shall be installed in an accessible location. Inlet Pressure: Not exceeding Max. 5.0 Kg/Sq.cm Outlet Pressure: 1.5 Kg/Sq.cm LOCATION: INSIDE SHAFT

-

-

-

... More
32 mm dia (Brass Housing - PRV)

10

-

-

... More
40 mm dia (Brass Housing - PRV)

4

-

-

... More
50 mm dia (Brass Housing - PRV)

5

-

-

... More
65 mm dia (Brass Housing - PRV)

11

-

-

... More
80 mm dia (Brass Housing - PRV)

9

-

-

... More
100 mm dia (Brass Housing - PRV)

1

-

-

... More
Providing, Fixing, jointing,testing and commissioning of FRP Manhole Cover Medium duty (12.5 Ton point load) with frame, double seal, water proof locking arrangement and lifting hooks and to be tested as per BS EN 124 & AASHTO M306, complete in all regards with all necessary accessories, as per specification/drawings and as directed by PMC/Employer . LOCATION: UGT, OHT AND SUMP PIT

-

-

-

... More
600 mm x 600 mm (Top Access) for OHT

17

-

-

... More
900 mm x 900 mm (Top Access) for Sump pit

13

-

-

... More
1000 mm x 1000 mm (Side Access) for UGT

13

-

-

... More
Providing, fixing, jointing, testing and commissioning of heavy duty floating flange EPDM rubber expansion joint with unit control (tie rod & gusset plate) as per manufacturers specifications of standard length complete with all accessories tested to a pressure not less than 15 Kg./sqcm including rubber gaskets, flanges, nuts, bolts & washers complete as required, as per specification/drawings and as directed by PMC/Employer . LOCATION: PUMP SUCTION & DISCHARGE LINE

-

-

-

... More
40 mm dia

5

-

-

... More
50 mm dia

5

-

-

... More
65 mm dia

13

-

-

... More
80 mm dia

9

-

-

... More
100 mm dia

48

-

-

... More
150 mm dia

5

-

-

... More
Providing, installation, testing and commissioning of Stainless Steel body Y- strainer screen fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with Stainless Steel flange. as directed by PMC/Employer . LOCATION: PUMP ROOM & TERRACE OHT

-

-

-

... More
80 mm dia

3

-

-

... More
100 mm dia

8

-

-

... More
150 mm dia

14

-

-

... More
200 mm dia

1

-

-

... More
Providing and fixing 600 mm long MS hot dip galvanized PUDDLE FLANGES fabricated out of 6 mm thick MS plates of suitable size and IS:1239 / IS 3589 heavy class pipes properly fixed in walls & top slab of tanks. The entire fittings shall be hot dipped galvanized after fabrication. Length shall be minimum 600 mm or wall thickness plus 200 mm on either side (which ever is more) as per specification/ drawings and as directed by PMC/Employer. LOCATION: UGT, OHT, RETAINING WALL

-

-

-

... More
25 mm dia (Threaded type)

22

-

-

... More
50 mm dia (Threaded type)

22

-

-

... More
65 mm dia (flanged ends)

22

-

-

... More
80 mm dia (flanged ends)

28

-

-

... More
100 mm dia (flanged ends)

56

-

-

... More
150 mm dia (flanged ends)

67

-

-

... More
200 mm dia (flanged ends)

52

-

-

... More
250 mm dia (flanged ends)

9

-

-

... More
300 mm dia (flanged ends)

7

-

-

... More
Providing and fixing Blank flanges, making flanged joints with bolts, nuts, washers and rubber insertion 3 mm thick, testing the flange and joints etc. complete for pipes of following diaMetre as per specification/ drawings and as directed by PMC/Employer.

-

-

-

... More
25 mm dia

4

-

-

... More
50 mm dia

5

-

-

... More
65 mm dia

7

-

-

... More
80 mm dia

6

-

-

... More
100 mm dia

11

-

-

... More
150 mm dia

15

-

-

... More
200 mm dia

11

-

-

... More
250 mm dia

1

-

-

... More
300 mm dia

1

-

-

... More
Providing and Fixing PVC mould CI Steps for Sump as per specification/drawings and as directed by PMC/ Employer LOCATION: UGT, OHT, SUMP PIT, CHAMBERS

326

-

-

... More
Providing, fixing, jointing, testing and commissioning of Water Metre with direct reading dial in KL for cold and hot water line with all necessary fittings such as threaded pieces, unions, 1 no. pressure gauge with ball valve, 1 no. NRV, 2 nos. isolation valve at inlet and outlet, flanges piece for future removal, flanges/ unions complete with all necessary testing charges and obtaining test certificates from municipal authorities, on following size pipe lines. The water Metre shall have RS-485/Modbus/BACnet over IP/ BACnet over MSTP port to integrate with Building Management System without any external hardware/converter requirement. Technical integration details shall be provided by Plumbing contractor to BMS contractor and ensure proper integration is done, it shall also comply to ISO 4064 standard, feasible for class B or Class A installation with all necessary accessories, as per specification/drawings and as directed by PMC/ Employer LOCATION: IN PLANTROOMS, ON PUMPING MAIN FOR DOMESTIC,FLUSHING, IRRIGATION & HVAC MAKEUP WATER LINES AND KITCHEN DISTRIBUTION LINES.

-

-

-

... More
25 mm dia

15

-

-

... More
32 mm dia

15

-

-

... More
40mm dia

15

-

-

... More
50mm dia

4

-

-

... More
65mm dia

4

-

-

... More
80mm dia

4

-

-

... More
100mm dia

2

-

-

... More
150mm dia

1

-

-

... More
200mm dia

1

-

-

... More
Providing, Fixing, Jointing and Testing in position the Two Way Connection Fitting of Heavy Class (Class C) G.I. Pipes cut to required lengths for Two Way connection Fitting at the gate for tanker water supply connection including all necessary fitting and specials such as bends, tees, uniform, reducer, flanges, plugs, Non return Valve and Butterfly Valve etc. threading jointing and making proper connections. Cutting hole in wall / floor / slab and making good the same. LOCATION: EXTERNAL

-

-

-

... More
Fixing / Supporting the Pipes at Wall / Ceiling level supported by galvanized clamps, hangers etc. as per specification. Exposed pipes to be provoided with two coats of synthetic enamel paint over a coat of primer, including painting of legends with direction arrows. (Tanker Water Supply) LOCATION: EXTERNAL

-

-

-

... More
100mm NB

2

-

-

... More
Supply, installation and fixing testing and commissioning of Horizontal approved make electically operated storage Geysers / Water Heater inner container made from copper or stainless steel including the remal instalation safety valve, vacuum relief valve, neon lamp, mounting brackets, angle valve, connection hose installing in position with coach screws or bolts, nuts, testing, commissioning, etc, complete.

-

-

-

... More
Capacity 15 liters

2

-

-

... More
Capacity 25 liters

2

-

-

... More
Capacity 50 liters

2

-

-

... More
Capacity 100 liters

7

-

-

... More
Providing & fixing Water Hammer Arrestor of rating PN 10 as applicable confirming to ASSE 1010.including flanges, union, nuts, bolts, washers & painting complete as required. BODY : Hard Drawn Copper with Custom Internal Mirron FinishPiston : TeflonSeals : ‘O’ Rings, (2) EPDMWorking Pressure : 150 Psi (10 Bar)Temperature Range : 33°F it 180°F (0.5°C to 82°C) LOCATION: TOILETS

-

-

-

... More
15mm dia PDI Code-'A'

156

-

-

... More
20mm dia PDI Code-'B'

156

-

-

... More
25mm dia PDI Code-'C'

4

-

-

... More
25mm dia PDI Code-'D'

4

-

-

... More
25mm dia PDI Code-'E'

4

-

-

... More
25mm dia PDI Code-'F'

4

-

-

... More
DRAINAGE

-

-

-

... More
Providing, Laying, Testing & Commissioning of 'B' class medium duty G.I. Pipe conforming to IS 1239 including welding, fitting like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coat of synthetic enamel paints of required shade complete as required and directed by PMC/Employer LOCATION: AHU DRAIN SHAFT

-

-

-

15

-

-

15

-

-

14

-

-

14

-

-

15

-

-

30

-

-

412

-

-

15

-

-

... More
Providing, Fixing, Testing and Commissioning of uPVC SWR (Type B) Pipe for Soil, Waste, Rain water System Installation confirming to IS 13592-1992 and fitting confirming to IS 14735:99 (Pipe Class B). Cut to required lengths including all necessary fitting and specials such as bends, junctions, offsets, acess pieces (plain or door), Vent Cowls with brass mosquito proof . Cost shall be inclusive of Fixing / Supporting the Pipes at Wall / Ceiling level supported by galvanized clamps, hangers, angle brackets, anchor fasteners etc. as per specification. LOCATION: INSIDE TOILET & SHAFT

-

-

-

... More
75mm NB

903

-

-

... More
110mm NB

4639

-

-

... More
160mm NB

935

-

-

... More
200mm NB

21

-

-

... More
250mm NB

21

-

-

... More
Providing, Fixing, Testing and Commissioning of uPVC SWR (Type B) Pipe for Soil and Waste Water System Installation confirming to IS 13592-1992 and fitting confirming to IS 14735:99 (Pipe Class B). Cut to required lengths including all necessary fitting and specials such as bends, junctions, offsets, acess pieces (plain or door). The pipes shall be running over slab (in -filling) in areas such as toilets, kitchen etc. Cost shall be inclusive of providing and laying 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate of 12 mm size) cement concrete below the joints of pipe, Cost shall be inclusive of making maximum of 130mm X 130mm chasing in wall / floors for the pipe; making good the same using 1:1 cement mortar over the embedded pipes and fittings, complete as required. as per technical specifications and drawings. LOCATION: INSIDE TOILET & WET AREAS (IN FILLING)

-

-

-

... More
75mm NB

117

-

-

... More
110mm NB

266

-

-

... More
Providing, Fixing, Jointing, Testing and Commissioning of Rigid uPVC Pipe for Soil, Waste Installation confirming to IS 4985 Class 3 PN 6 and fitting confirming to IS 7834. Cut to required lengths including all necessary fitting and specials such as bends, junctions, offsets, acess pieces (plain or door). The pipes shall be running over slab (in -filling) / concealed in wall in areas such as toilets, kitchen etc. Cost shall be inclusive of providing and laying 1:2:4 cement concrete below the joints of pipe. Cost shall be inclusive of making maximum of 100mm X 100mm chasing in wall / floors for the pipe; making good the same using 1:1 cement mortar over the embedded pipes and fittings, complete as required. If running through ceiling level cost shall be inclusive of galvanized clamps, hangers, anchor fastners at maximum of 1m interval etc. as per specification. LOCATION: INSIDE TOILET & WET AREAS

-

-

-

... More
40mm NB

398

-

-

... More
50mm NB

155

-

-

... More
Providing, Fixing, Jointing, Testing and Commissioning of Rigid uPVC Pipe for Soil, Waste Installation confirming to IS 4985 Class 4 PN 8 and fitting confirming to IS 7834. Cut to required lengths including all necessary fitting and specials such as bends, junctions, offsets, acess pieces (plain or door). The pipes shall be running over slab (in -filling) / concealed in wall in areas such as toilets, kitchen etc. Cost shall be inclusive of providing and laying 1:2:4 cement concrete below the joints of pipe. Cost shall be inclusive of making maximum of 100mm X 100mm chasing in wall / floors for the pipe; making good the same using 1:1 cement mortar over the embedded pipes and fittings, complete as required. If running through ceiling level cost shall be inclusive of galvanized clamps, hangers, anchor fastners at maximum of 1m interval etc. as per specification. Note: uPVC SWR (Type B) to Rigid uPVC Pipe Class 4 PN 8 adaptor flange to be provided LOCATION: FIRST FLOOR CEILING DIVERSION & GROUND FLOOR TOILETS.

-

-

-

... More
75mm NB

31

-

-

... More
110mm NB

140

-

-

... More
160mm NB

138

-

-

... More
200mm NB

210

-

-

... More
Providing, fixing, jointing, testing and commissioning Hubless C.I. pipe for soil, waste pipes installation conforming to IS:15905, stainless steel coupling with EPDM rubber as per DIN 19543, cut to required lengths including all necessary fittings and specials such as Bends, junctions, offsets, access pieces (plain or door) & vent cowl. Fixing at wall/ceiling level supported by galvanized steel clamps & hangers etc. duly epoxy coated.Cutting, chases/holes in floors / walls / slab with all necessary accessories as per specification/ drawings and directed by PMC/Employer. NOTE: HUBLESS C.I. PIPE TO SPUN / CENTRIFUGALY CAST CI PIPE ADAPTOR FLANGE TO BE PROVIDED LOCATION: KITCHEN

-

-

-

... More
Cost shall also be inclusive of painting the pipes & fittings with two coats of synthetic enamel paint of approved shade over a coat of primer.

-

-

-

... More
40 mm dia

66

-

-

... More
50 mm dia

58

-

-

... More
75 mm dia

58

-

-

... More
100 mm dia

112

-

-

... More
150 mm dia

118

-

-

... More
Providing, fixing, jointing, testing and commissioning of Spun / Centrifugaly cast CI pipe for soil, waste installation conforming to IS:3989 to required layouts including all necessary fittings & specials such as bends, junctions offsets, access pieces. The pipes shall be running at ceiling suspended in basement area. Fixing at wall/ceiling level supported by galvanized steel clamps & hangers etc. duly epoxy coated.Cutting, chases/holes in floors / walls / slab with all necessary accessories as per specification/ drawings and directed by PMC/Employer. Ground floor toilet drainage and kitchen drainage. NOTE: UPVC TO SPUN / CENTRIFUGALY CAST CI PIPE ADAPTOR / COUPLING FLANGE TO BE PROVIDED LOCATION: BASEMENT-01 HORIZONTAL DIVERSION

-

-

-

... More
Cost shall also be inclusive of painting the pipes & fittings with two coats of synthetic enamel paint of approved shade over a coat of primer.

-

-

-

... More
100 mm dia

57

-

-

... More
150 mm dia

699

-

-

... More
200 mm dia

31

-

-

... More
Providing and fixing in position hubless CI full bore P trap confirming to IS 15905 including SS coupling with EPDM rubber as per DIN 19543 of the following sizes for underslab location including providing necessary galvanized steel support and as per Specification and duly epoxy coated. Cutting chase / hole in floors / slabs and bringing the same in proper condition and shape after placing the trap in right position complete by supporting by GI clamps / hangers as required with all necessary accessories as per specification/ drawings and directed by PMC/Employer LOCATION: KITCHEN, GROUND FLOOR TOILET

-

-

-

... More
100 mm inlet and 100 mm outlet

45

-

-

... More
Providing, fixing, jointing, testing and commissioning of cleaning eye on horizontal CI soil & waste pipes, made of 300 mm long GI pipe with one plain end drip seal caulked in to the collar of CI pipe and the other end with flange which in covered by neoprene rubber gasket and blank flange, complete with nuts, bolts etc and hot dip galvanization with all necessary accessories as per specification/ drawings and directed by PMC/Employer.

-

-

-

... More
For 100 mm dia pipe

15

-

-

... More
For 150 mm dia pipe

60

-

-

... More
For 200 mm dia pipe

20

-

-

... More
Providing, fixing and testing C.I multi floor trap of self cleansing design with arm and provision for connection C.I /G.I pipe inlet fitting complete including cost of cutting and making good the walls and floors wherever required. Multifloor trap 75 mm outlet with 100 mm inlet LOCATION: GROUND FLOOR TOILET

5

-

-

... More
Providing, fixing and testing C.I P trap of self cleansing design with arm and provision for connection C.I / G.I pipe inlet fitting complete including cost of cutting and making good the walls and floors wherever required. LOCATION: AHU ROOM

-

-

-

... More
75mm DN

6

-

-

... More
100mm DN

31

-

-

... More
Providing and fixing in position 100 mm x 75mm Cast Iron Nahini / Floor Trap of self cleaning design joining, embedding in concrete etc. complete. Rate to include making of opening in floor, marble / tiles, for fixing grating with all necessary accessories, as per specification/drawings and as directed by PMC/Employer. LOCATION: KITCHEN (IN FILLING)

14

-

-

... More
Providing & fixing in position 75mm uPVC Multitrap with 50mm water seal of self cleaning design. Including fixing of SS grating for under Washbasin/Sink Multitrap, jointing, embedding in concrete etc. complete. Rate to include making of opening in floor, marble / tiles for fixing SS gratings etc. LOCATION: TOILETS( SUSPENDED CEILING)

14

-

-

... More
Providing & fixing in position 75mm uPVC Nahnitrap with 50mm water seal of self cleaning design. Including fixing of SS grating for floor drain Nahni trap, jointing, embedding in concrete etc. complete. Rate to include making of opening in floor, marble / tiles for fixing SS gratings etc. LOCATION: TOILETS (IN FILLING)

72

-

-

... More
Supply, installation and testing of uPVC P traps of self cleansing design with 50mm water seal complete with: i) setting the trap in cement Trap with 75 inlet & 110 mm outlet.

528

-

-

... More
Providing, Fixing, testing and commissioning in position PVC Clean Out with plug suitable for pipe diametre with a seal tight cover. Making proper connection with refined drip seal joints, bringing the same in proper condition and shape after placing it in right position complete as required and as per drawings. LOCATION: TOILETS( SUSPENDED CEILING)

-

-

-

... More
75mm NB

93

-

-

... More
110mm NB

184

-

-

... More
160mm NB

66

-

-

... More
Providing and fixing 110 uPVC inlet hopper with P trap of water seal depth 50mm including two or three inlets fittings to receive waste pipes from fixtures waste. .

60

-

-

... More
Providing and fixing heavy duty S.S. Floor grating with frame of approved design including setting in floor with cement motor to match with floor finish as directed by PMC/Employer. LOCATION: AHU ROOM, TOILETS

-

-

-

... More
Size 100 mm x 100 mm or 100 mm dia

20

-

-

... More
Size 150 mm x 150 mm or 125 mm dia

590

-

-

... More
Providing and fixing heavy duty S.S. Floor Clean out with frame of approved design including setting in floor with cement motor to match with floor finish as directed by PMC/Employer. LOCATION: TOILETS

-

-

-

... More
Size 100 mm x 100 mm or 100 mm dia

10

-

-

... More
Size 150 mm x 150 mm or 125 mm dia

289

-

-

... More
Designing, Providing, fixing, jointing, testing and commissioning of pre-fabricated grease interceptor suitable for underground application, Heavy duty cover, inlet outlet, overflow, sludge suction connection, excavation & backfilling of grease storage tank including all accessories complete as required or as per manufacturer specification as and directed by PMC/Employer. suitable for below ground application, conforming to EN 1825 / DIN 4040-100. LOCATION : EXTERNAL FOR KITCHEN WASTE

-

-

-

... More
Flow rate: 3 - 7 LPS

1

-

-

... More
Designing, Providing, fixing, jointing, testing and commissioning of Underground Prefabricated HDPE material Lifting Station, storage chamber with clean-out opening and Pressure sensor controlled lifting station with non-cookable impeller to pump wastewater with or without sewage suitable for adequate pump capacity as mentioned below. Pump cable length shall suit the site requirement with connection for inlet and ventilation, connection for coupling with pump. Vertical / horizontal outlet with integrated non-return valve. Comfort control unit with mains power ON / OFF switch and multilingual digital display showing current operational status. Control unit is IP 55, wall mounted, voltage 230 / 400 V at 50 Hz. With potential free contact and including all accessories complete as required or as per manufacturer specification and as directed by PMC/Employer, Pump configuration (1W+1S) to be considered. LOCATION : BASEMENT-01 FOR KITCHEN WASTE

-

-

-

... More
Flow rate: 3 - 7 LPS Head: 15 m -20 m

1

-

-

... More
Providing and Fixing of approved make scupper drain (Side wall type rain water outlet) CI body with C.I grating, with lead flashing around the pipe with one piece lead sheet of 3mm thick set on a layer of old bitumen, threaded adaptor for coupling connection etc with SS screw as per drawings complete with all necessary accessories, as per specification/drawings and as directed PMC/Employer. LOCATION: AT TERRACE Purpose: side outlet - Scrupper

-

-

-

... More
75mm dia outlet

33

-

-

... More
100 mm dia outlet

5

-

-

... More
150 mm dia outlet

16

-

-

... More
200 mm dia outlet

4

-

-

... More
Supplying and fabricating by welding / electroforging, and fixing in position Heavy duty MS structural steel 25mm thk grating Suitable for 300mm width clear opening channel, work made up of flats and roads including all necessary fixtures, fasteners, all material and labour complete in all respects. The grating shall be hot dip galvanised to 610grams/sgm. LOCATION: PUMP ROOM DRAIN

77

-

-

... More
Supply and fixing framed FRP grating and mounting frame suitable for 12.5 Ton point load complete with painting & designation. (For pump room surface drain) Grating Suitable for 300mm width clear opening channel. LOCATION: PUMP ROOM DRAIN

77

-

-

... More
Providing and fixing Stoneware Gully Trap of size 150mm x 100m with Cast Iron Double Gratings. LOCATION: EXTERNAL

4

-

-

... More
Providing, Fixing, Testing and Commissioning of ACO Drain Channel or Equivalent with stainless steel single slotted grating. Drain Channel shall have base material as Polymer concrete or equivalent material as approved by PMC/Employerconforming to EN 1433 specification. It should be Pre casted for ready to use. Channel drain shall be of U or V shaped cross section.It should provide water tight laying. Grating should be of 15mm width or as approved by PMC/Employer & clear width as specified polymer concrete channel having one side slope including necessary fittings such as inspection element, end cap, side and bottom outlet and any other items required for complete installation. The grating shall have locking system so that it can fit on safety groove and openable grating units for maintenance complete as per specification/drawings and as directed by PMC/Project Engineer for Refuge area Terrace drainage. At final discharge point (sump pit) shall have mesh arrangement. LOCATION: REFUGE AREA TERRACE

-

-

-

... More
Clear width of 100 mm and initial depth of minimum 100 mm

120

-

-

... More
Clear width of 100 mm and initial depth of minimum 150 mm

60

-

-

... More
Clear width of 100 mm and initial depth of minimum 200 mm

15

-

-

... More
RAINWATER FILTRATION

-

-

-

... More
Supplying, installing, testing, commissioning and Handing over of approved make Pressure sand filter of MS construction with Epoxy coating complete with necessary accessories like Frontal piping, valves, suitable supports for mounting, pressure gauge and orifice plate. The filter shall also include initial charge of under bed and multi – grade filter media to suite the requirement complete. Etc. as per the detailed specification for the efficient working of system. The inside of filter should have Food grade Neoprene rubber line of 4mm thick. The cost shall include the inter unit piping with necessary flanges, bolts, nuts, neoprene gaskets, welding wherever necessary, with necessary control valves, non return valves etc., and with one coat of primer and two coats of approved enamel paint etc., complete The maximum working Pressure shall be 3.5 Kg / Sqcm. Capacity : 17 Cum / hr LOCATION: PUMP ROOM

1

-

-

... More
Supplying, installing, testing and commissioning and handing over of approved make Activated carbon filter of MS construction with Epoxy coating and initial charge and complete with all necessary accessories like Frontal piping, valves, suitable supports for mounting, pressure gauge and orifice plate etc. The filter should comply to all technical specifications for the efficient working of the system. The cost shall include the inter unit piping with necessary flanges, bolts, nuts, neoprene gaskets, welding wherever necessary, with necessary control valves, non return valves etc., and with one coat of primer and two coats of approved enamel paint etc., complete The maximum working Pressure shall be 3.5 Kg / Sqcm. Capacity : 17 Cum / hr. LOCATION: PUMP ROOM

1

-

-

... More
MISCELLANOUS

-

-

-

... More
Providing GI pipe sleeves suitable higher size shall be provided wherever the pipes are crossing the fire rated walls / beams / floor slab and sealing the sleeves with glass wool in between and fire sealant compound at either end all as suggested by PMC/Employer.

-

-

-

... More
15 mm dia

26

-

-

... More
20 mm dia

26

-

-

... More
25 mm dia

26

-

-

... More
32 mm dia

26

-

-

... More
40 mm dia

130

-

-

... More
50 mm dia

220

-

-

... More
65 mm dia

130

-

-

... More
80 mm dia

130

-

-

... More
100 mm dia

130

-

-

... More
150 mm dia

115

-

-

... More
200 mm dia

65

-

-

... More
250 mm dia

10

-

-

... More
Providing and wet drilling accurate and clean holes of specified diaMetre in RCC walls, slabs, beam or any other RCC member without vibration for laying service lines by Core cutting (diamond drilling) machine of approved make including scaffolding, safety majors, disposing the debris, cleaning, making good, sealing the joints around the service

-

-

-

... More
pipes with suitable material, nominal reinforcement wherever required for all levels/ all height, after approval of PMC/Employer etc complete. Measurement shall be taken for the depth of holes in running Metre for specified diaMetre. Holes shall made by authorized approved agency. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes

-

-

-

... More
50 mm dia

70

-

-

... More
75 mm dia

70

-

-

... More
100 mm dia

420

-

-

... More
150 mm dia

390

-

-

... More
200 mm dia

28

-

-

... More
250 mm dia

14

-

-

... More
Supply and delivery and fixing of HDPE tank as per IS 12701 / 1996 including loading, unloading, transportation and labour charges for fixing of the GI pipes and specials for pipe connection works including cutting, threading and fixing charges etc.,complete Shades/color as directed by PMC/Employer LOCATION: GUARD BLOCK

-

-

-

... More
a)2000 Ltrs Capacity

2

-

-

... More
SEWAGE TREATMENT PLANT (STP)

-

-

-

... More
STP BASED ON MBR TECHNOLOGY - 250 KLD, CTBD ETP 70 KLD & REVERSE OSMOSIS SYSTEM 200 KLD

-

-

-

... More
Note: Contractor shall note that BOQ and flow parameter indicated are for guidance only. Contractor shall check and confirm the same. How-ever any other item required for satisfactory operation of STP and recycling system, shall be included in the scope of work and same shall be mentioned in the BOQ.

-

-

-

... More
The scope includes but not limited to the design, detailed engineering, construction, manufacture, procurement and supply of all materials and equipment, receipt, storage, conservation & preservation of all materials including all civil, structural steel works (sheds, platforms, ladders, etc.),masonry works,plastering ,finishes, interconnecting piping, electrical, instrumentation, fabrication, painting, inspection & testing at bidder’s works, packing, forwarding, transportation, transit insurance, delivery at site, erection/installation, testing, commissioning at site and carrying out performance / acceptance guarantee test runs. Civil works of construction of basement and superstructure and complete wastewater recycling system is in STP Vendors scope. 1. Sewage Treatment Plant based on MBR Technology process, with total sewage handling capacity of 250 KLD to be treated in 22 hours /day 2. CTBD Effluent Treatment Plant based on media filtration followed by Ultrafiltration technology, with total CTBD effluent handling capacity of 70 KLD with 20 hours/day. 3. Reverse osmosois system for recycling treated sewage and UF treated CTBD effluent of capacity 200 KLD with 20 hours/day operating capacity

1

-

-

... More
STP has to be constructed with basement upto full depth and one floor (for staircase headroom) above the ground at OSR area.

-

-

-

... More
The work is required to be carried out on a lumpsum basis (Including Civil Works) covering a guarantee of satisfactory performance as per the standards. The contractor will be solely responsible for smooth running of the sewage treatment plant and overall functioning of STP. In case it is found in the later stage that some additional fixtures / equipment are required to be added in order to achieve desired quality, the contractor would be liable to provide without any extra charges.

-

-

-

... More
The STP, CTBD ETP and RO system should follow all the concern Indian and Local norms.

-

-

-

... More
The Plant shall consist of following units but not limited to these units as may be required by the manufacturer's design to achieve the desired quality parameters in treated sewage.

-

-

-

... More
The Plant shall be complete with a central Electrical Power and Control panel fully pre/site wired and with all power and control cables to all pumps and equipment including all instrumentation, water level controllers and other controls. MCC, PLC are to be housed in a room / shed of suitable size to be built.

-

-

-

... More
All interconnecting pipings, aeration grids, puddle flange, inlet, outlet overflow, suitable cut-outs for material handling, ladders, lowering / lifting of equipment for complete wastewater recycling system, pulleys /equivalent provisions for lifting and lowering of equipments, vents, manholes cover, drain channel with gratings, rungs, sump to house pumps shall also be included.

-

-

-

... More
The STP, CTBD ETP and RO system shall be designed based on the tender specification details and parameters. The capacities of various tanks and pumps are guidelines to the vendor. The contractor has to submit detailed calculations of system and equipment he proposes to install. The STP, CTBD ETP and RO system shall consist of following units but not limited to these unit as may be required by the manufacturer's design to achieve the desired quality parameters in treated sewage.

-

-

-

... More
The exact Invert level of incoming sewage should be finalised by Vendor before start of construction.

-

-

-

... More
Technical/liasioning support while taking Approval from pollution board at initial & various other stages of works including preparation of report / drawings as per pollution board requirement, arrangement of raw sewage for testing & commissioning. Contractor shall include the cost of all chemicals consumed during testing & commissioning and the cost of such items of works which are not explicitly mentioned above, but are mandatory to have pollution board approval. (All relevant fee for PCB Approval shall be paid by client).

-

-

-

... More
The Contractor shall have to submit detailed structural analysis model, detailed design calculations,GA Drawings Plan & Section, Structural drawings (GFC), Fabrication Drawings, P & I diagram, Hydraulic Flow Diagram, schematic diagram, shop drawings, as built drawings and all other drawings / documents as indicated in Tender Specifications of the plant indicating all sleeves etc for the various component and additional component if so required for the complete working of the STP also indicating all components in the STP area for PMC/Employer approval.

-

-

-

... More
Contractor shall prepare and submit DBR for STP design and get it approved by PMC/Employer before proceeding with structural design. The contractor should design STP & prepare good for construction structure drawing and get it approved by PMC/Emplyer. Contractor to submit design report for STP design consists of load calculations, foundation design calculations, analysis models such as ETABS/STAAD/SAFE, structural layout drawings, reinforcement drawings etc. to PMC/Employer and get the same approved by PMC/Employer. Upon approval contractor to get the design and drawings proof checked from reputed institutions like IIT/Anna University before proceeding with execution of work.

-

-

-

... More
Notes: 1)The rates will include all pumps, piping, valves, controls, tanks and membranes, blowers, diffusers, central Electrical Power and Control panel with all power and control cables to all pumps and equipment including all instrumentation, water level controllers and other controls. 2) The quoted rate shall include the costs towards the items which are not specifically mentioned in the specifications, Price Schedule (BOQ) and drawings but necessary for completion of the purpose of work and satisfactory performance of the STP.

-

-

-

... More
Nature of Effluent : Domestic sewage & cooling tower blowdown

-

-

-

... More
Raw Sewage (Normal Flow) : 250 KLD Peak factor : 3 Plant operating Time : 22 Hours per day Sludge dewatering system operating time : 16 Hours per day Treatment Process : Membrane Bioreactor (MBR) Technology CTBD Effluent : 70 KLD CTBD Effluent Treatment Plant operating Time : 20 Hours per day RO system : 200 KLD RO system operating Time : 20 Hours per day

-

-

-

... More
BASIC DATA ON INFLUENT RAW SEWAGE pH: 6.5 to 8.0 COD: 400 to 500 mg/L BOD, 5 days @ 200C: 250 to 300 mg/L Suspended solids: 300 to 400 mg/L Total Nitrogen: 50 mg/L Organic Nitrogen: 15 mg/L Ammonia Nitrogen: 35 mg/L Nitrate Nitrogen: 5 mg/L Total Phosphorous: 7-8 mg/L Oil & grease: 25 to 50 mg/L

-

-

-

... More
ANTICIPATED QUALITY OF COOLING TOWER BLOW-DOWN EFFLUENT pH: 6.5 to 9.0 Hardness: 750 mg/L as CaCO3 Alkalinity: 500 mg/L as CaCO3 Total Dissolved Solids: 1100 mg/L Conductivity : 2000 micromhos Chlorides as Cl : 200 mg/L Sulphates : 500 mg/L Silica :75 mg/L Total Phosphorous : 7-8 mg/L TSS :100 mg/L

-

-

-

... More
TREATED SEWAGE CHARACTERISTICS FOR TOILET FLUSHING pH:6.5– 8.3 Oil & Grease: 5 mg/L Total suspended solids:5 mg/L BOD: 6 mg/L COD: 50 mg/L Total nitrogen (N):10 mg/L Total phosphorous:2 mg/L Faecal Coliforms : Nil Turbidity: 2 NTU Total Dissolved Solids: 2100 mg/lit

-

-

-

... More
RO REJECT CHARACTERISTICS FOR IRRIGATION pH : 5.5-9.0 TSS: 20 mg/l BOD: 10 mg/l COD : 50 mg/l Oil & Grease: 10 mg/l Total Nitrogen: 10 mg/l Total Phosphorous: 1 mg/l Faecal Coliforms : Nil Total Dissolved Solid: 2100 mg/l

-

-

-

... More
RO PERMEATE CHARACTERISTICS REQUIRED FOR HVAC MAKE-UP pH: 6.5-8.3 Hardness: 50 mg/l as CaCO3 Total Dissolved Solids: 250 mg/l

-

-

-

... More
The STP, CTBD ETP and Recycle system shall be designed based on the given parameters. The capacities of various tanks and pumps are guidelines to the vendor. Civil works of STP and Recycle system including construction of full depth of basement and one floor above ground is in contractors scope. The contractor has to submit detailed calculations of system and equipment he proposes to install.

-

-

-

... More
The contractor will be solely responsible for smooth running of the sewage treatment plant and overall functioning of STP till end of defects liability period. In case it is found during this period that some additional fixtures / equipment are required to be added in order to achieve desired quality, the contractor would be liable to provide without any extra charges.

-

-

-

... More
TANKS AND CHAMBERS & BUILDING (Civil and structure works shall be in Vendors scope. Grade of concrete shall be M30.

-

-

-

... More
Coarse & Fine Bar Screen chamber - Coarse bar screen and 1 no. Fine bar screen with suitable lifting arrangements complete as required. (Minimum 1 number)

-

-

-

... More
Oil & Grease Tank - Complete in all respect with baffle wall, compartment wall, inlet, outlet etc. , etc. (Minimum 1 number)

-

-

-

... More
RCC EqualisationTank - (Capacity shall be minimum 65 m3 - 6 Hrs. HRT for design flow) for collecting sewage. Provision for aeration of system will be kept with air grid with suitable arrangements and civil supports .(Minimum 1 number)

-

-

-

... More
Anoxic tank - With Suitable Capacity along with suitable provision for the maintenance of submersible mixer. Required RCC Platform for maintenance. (Minimum 2 number)

-

-

-

... More
Aeration Tank - (With Suitable Capacity) along with suitable provision for retrievable diffuser membrane system Tanks with air diffusion system arrangement and piping complete of adequate capacity. Required RCC Platform for maintenance. (Minimum 2 number)

-

-

-

... More
MBR Tank - (With Suitable Capacity) along with suitable provision for Membrane Cleaning (Minimum 2 number)

-

-

-

... More
MBR Permeate Tank - Capacity shall be minimum 22 m3 - 2 Hrs. HRT for design flow . Same tank can be modified to use as backpulse tank (Minimum 1 number)

-

-

-

... More
Sludge Holding Tank - (Sludge Storage - minimum 24 hrs. according to sludge volume) . (Minimum 1 number)

-

-

-

... More
CTBD Collection Tank - Capacity shall be minimum 12 m3 - 4 Hrs. HRT for design flow. (Minimum 1 number)

-

-

-

... More
UF Feed Tank -Capacity shall be minimum 6 m3 - 2 Hrs. HRT for design flow

-

-

-

... More
MBR Permeate + CTBD UF permeate Tank/ RO Feed Tank - Capacity shall be minimum 18 m3 - 2 Hrs. HRT for design flow (Minimum 1 number)

-

-

-

... More
RO Permeate tank - Capacity shall be minimum 10 m3 - 2 Hrs. HRT for design flow. (Minimum 1 number)

-

-

-

... More
RO Reject tank - Capacity shall be minimum 8 m3 - 2 Hrs. HRT for design flow. (Minimum 1 number)

-

-

-

... More
Construction of basement area for STP with forced air ventilation system including all civil works like excavation,shoring ,shuttering ,dewatering,backfilling with suitable earth as approved by PMC, disposal of unsuitable earth at designated locations, waterproofing below the raft,outside of retaining walls, inter walls and base slab of sump tanks,RCC works ,formwork, reinforcement, plastering,finishing,etc. Construction of superstructure (staircase headroom) for STP includes RCC works ,formwork, reinforcement, plastering,masonry works,finishing, flooring, painting, doors, windows,etc. complete.

-

-

-

... More
MCC / PLC room shall be of adequate size to house MCC / PLC Panel for 250 KLD STP, 70 KLD CTBD ETP and 200 KLD RO system & provided with Air ventilation system

-

-

-

... More
Chemical storage

-

-

-

... More
Foundations for all blowers, pumps , tanks , skids and pipe work

-

-

-

... More
All drains with gratings, trenches upto battery limits

-

-

-

... More
Supports for electrical wire, cables, pipes etc.

-

-

-

... More
All required Platforms, Staircases, handrails, walkways, cutouts for maintenance

-

-

-

... More
Support Structure for Decanter Centrifuge

-

-

-

... More
ELECTRO MECHANICAL WORKS

-

-

-

... More
Note : 1. Pump capacity / head may vary and bidder to provide as per their design. Should be substantiated during detailed engineering 2. Provision of pump sets can change as per bidders design and hydraulics 3. Necessary lifting arrangement should be provided for submersible pumps and submersible Mixers. 4. Supply, installation, testing and commissioning of following electro mechanical works and equipments but not limited to these units shall be considered to achieve the desired quality parameters in treated sewage.

-

-

-

... More
S.S. 316 Manual coarse bar screen in screen chamber for peak flow- 10 mm opening with suitable lifting arrangements complete as required.(1 no.)

-

-

-

... More
S.S. 316 Manual fine bar screen in screen chamber for peak flow- 6 mm opening with suitable lifting arrangements complete as required. (1 no.)

-

-

-

... More
MSEP slotted pipe oil skimmer of suitable capacity .Slotted pipe type with necessary arrangements in Oil & Grease Trap. (1 No.)

-

-

-

... More
Equalised Sewage Transfer pumps of 3 Nos. (2W +1S) of duty 6 Cum/Hr @ 15 m head, vertical submersible pumps with casing/cover of Cast Iron(CI), impeller SS and shaft of SS, suitable for mechanical packed seal complete with base frame, pump driven by electric motor of suitable kW rating and RPM with IP 55 protection and class F insulation, foundation bolts, alongwith lifting arrangement etc. From Equalisation Tank to Fine screen prior to Anoxic tank (Cutter type Pumps) Solid handling capacity shall be 20 mm. (3 Nos.)

-

-

-

... More
Equalised Sewage Bypass pumps of 2 Nos. (1W +1S) of duty 13 Cum/Hr @ 35 m (approx.) head, vertical submersible pumps with casing/cover of Cast Iron(CI), impeller SS and shaft of SS, suitable for mechanical packed seal complete with base frame, pump driven by electric motor of suitable kW rating and RPM with IP 55 protection and class F insulation, foundation bolts, etc. alongwith lifting arrangement etc. From Equalisation Tank to nearest sewer drain during festive season only (Cutter type Pumps) Solid handling capacity shall be 20 mm. (3 Nos.)

-

-

-

... More
Twin lobe type rotary air blowers for Equalisation Tank & Sludge Holding Tank with suitable capacity with suction & delivery silencer, & all other necessary accessories, gauges etc. - Driven through "V" belt or directly coupled through flexible coupling to a TEFC motor suitable for 415 + 10% volts, 3 phase, 50 cycles A/C supply, coarse bubble air grid, complete with valves & air distribution grid complete with Acoustic Hood as required. Qty : 2 nos (1W+1S) Air supply rate - 0.9 m3 of air per m3 of Volume of the tanks. Common Air blowers shall be used to supply compressed air in Equalisation tank and Sludge Holding tank.

-

-

-

... More
Coarse bubble air grid for Equalisation tank and Sludge Holding tank ,MOC- UPVC (1 Lot)

-

-

-

... More
Drum Screen prior to Anoxic Tank - 2 mm Punched Hole MOC : Body CS Drum : SS 304 (2 Nos.)

-

-

-

... More
Submersible Mixers and its associated accessories and lifting arrangements etc. all complete in all respect. For Anoxic Tank. MOC : SS 304

-

-

-

... More
Twin lobe type rotary air blowers (VFD Driven) for Aeration Tank As per design (Approximately 100-120 Nm3/hr) with suitable capacity with suction & delivery silencer, & all other necessary accessories, gauges etc. - Driven through "V" belt or directly coupled through flexible coupling to a TEFC motor of suitable kW Suitable for 415 + 10% volts, 3 phase, 50 cycles A/C, supply of fine bubble membrane type diffusers complete with valves & air distribution grid complete with Acoustic Hood as required. Qty : 3 Nos. (2W +1S).

-

-

-

... More
Non clog type retrievable air diffuser system tubular type capable of handling desired flow of air. Air diffuser grid shall be assembled in modular form so that they can be replaced/ repaired easily from platform at the top. Air diffuser system shall be provided with fine air bubble type diffusers for Aeration tank as per Bidders design. MOC- EPDM Air flow rate per diffuser- 8 m3/hr per diffuser.

-

-

-

... More
Nitrifying liquor transfer pumps of 3 nos. (2W +1S) of duty of suitable capacity Min. 24 m3/hr and 12 m head , horizontal centrifugal pumps with casing/cover of Cast Iron(CI), impeller SS and shaft of SS, suitable for mechanical packed seal complete with base frame, pump driven by electric motor of suitable kW rating and RPM with IP 55 protection and class F insulation, foundation bolts,. Transferring mix liquor from MBR tank to Anoxic tank.

-

-

-

... More
MBR modules (for 22 hrs operation) submerged type housed in cabinet with membrane add on provision, to handle sewage of 250 KLD flow transmitter, turbidity analyser,automatic cleaning and recovery systems for the membrane, of Immersed hollow fiber, ultra filtration membrane with SS skid for housing the membranes alongwith Membrane Module Lifting Arrangements. Maximum Flux Permitted : 25 LMH Membrane MOC : PVDF Braket MOC : SS

-

-

-

... More
Membrane Lifting Arrangements : Monorail and electric hoist with electric travelling trolley of suitable capacity equivalent to 1.5 times the load of equipment to be lifted

-

-

-

... More
Twin lobe type rotary air blowers (VFD Driven) for MBR Tank As per design with suitable capacity with suction & delivery silencer, & all other necessary accessories, gauges etc. - Driven through "V" belt or directly coupled through flexible coupling to a TEFC motor of suitable kW Suitable for 415 + 10% volts, 3 phase, 50 cycles A/C, fine bubble membrane type diffusers complete with valves & air distribution grid complete with Acoustic Hood as required. Qty : 3 Nos. (2W +1S).

-

-

-

... More
ACOUTIC HOOD - For Air Blowers supplying air to Equalisation Tank & Sludge Holding Tank, Aeration Tank and MBR Tank, acoustical hood for each blowers in STP. Hood shall be made out of 16G GI sheet with 50mm thick open cell nitrile rubber of density 140-180 kg/cum. Care shall be taken for heat dissipation of motor while enclosed on hood. Openings in hood for piping shall be acoustically closed with fibre glass and silicon sealant etc.

-

-

-

... More
MBR Permeate pumps (VFD Driven) - 3 Nos. (2W +1S) of duty 6-8 Cum/Hr @ 10 m head, horizontal centrifugal pumps with casing/cover of Cast Iron(CI), impeller SS and shaft of SS, suitable for mechanical packed seal complete with base frame, pump driven by electric motor of suitable kW rating and RPM with IP 55 protection and class F insulation, foundation bolts, etc. From MBR Tank to MBR Permeate tank and Irrigation tank (For Blending)

-

-

-

... More
Backpulse pumps (VFD Driven) - 3 Nos. (2W +1S) of Suitable capacity - As per Membrane Manufacturer's deign - horizontal centrifugal pumps with casing/cover of Cast Iron(CI), impeller SS and shaft of SS, suitable for mechanical packed seal complete with base frame, pump driven by electric motor of suitable kW rating and RPM with IP 55 protection and class F insulation, foundation bolts, etc. for Membrane Cleaning

-

-

-

... More
Hypochlorite Dosing System for Disinfection of Treated Sewage and CTBD Effluent NaOCl dosing Pumps MOC : PP - 2 Nos. (1 W+1S) pumps with 1 no. HDPE dosing tank of suitable capacity.

-

-

-

... More
Hypochlorite Dosing System for CIP of Membrane System NaOCl dosing Pumps MOC : PP - 2 Nos. (1 W+1S) pumps with 1 no. HDPE dosing tank of suitable capacity.

-

-

-

... More
Citric Acid Dosing system along with agitator for CIP of Membrane System NaOCl dosing Pumps MOC : PP - 2 Nos. (1 W+1S) pumps with 1 no. HDPE dosing tank of suitable capacity with Agitator MOC- SS 304.

-

-

-

... More
Decanter Centrifuge Feed Pumps of 2 nos. (1W +1S) of 1 m3/hr capacity and 15 m head , horizontal centrifugal pumps with casing/cover of Cast Iron(CI), impeller SS and shaft of SS, suitable for mechanical packed seal complete with base frame, pump driven by electric motor of suitable kW rating and RPM with IP 55 protection and class F insulation, foundation bolts,. Transferring Sludge from Sludge Holding Tank to Centrifuge.

-

-

-

... More
Decanter Centrifuge 1 m3/hr capacity comprising of conical cylindrical bowl & scroll feed horizontally mounted in bearings on a frame. The centrifuge and scroll support frame shall be mounted on a fabricated sub-frame. All wetted parts shall be in SS 316 and housing in SS 304. Solid & Liquid chute in MSEP. 360 degree solids charge to avoid blocking. Fixed outlet castings of the rotor shall be designed to collect centrate and dewateered sludge from the rotor. The centrifuge shall be mounted on heavy-duty vibration isolators, located between the machine and the supporting steelwork or foundations, to damp vibrations and prevent vibration transmission. Two axis vibration monitors shall be provided to stop the centrifuge automatically when excessive vibration is detected. Flexible connections shall be provided on the sludge fed system and the centrate system at the centrifuge. The dewatered sludge discharge system shall incorporate flexible chutes. A variable speed drive shall be provided. Centrifuges shall produce a dewatered sludge cake of no less than 20% dewatered solids. At least 95- 98% of the solids shall be captured in the dewatered cake and less than 2% of the solids shall be in the centrate.

-

-

-

... More
Dewatering Polyelectrolyte (DWPE) Dosing System For Poly dosing 2 nos. Dosing pump MOC : PP -(1W+1S) with 1 No. HDPE Tank of suitable capacity with SS Mixer Dosage : 1.5-2.5 kg / ton of dry solids @ 0.1% solution strength

-

-

-

... More
Filter Feed Pumps of 2 nos. (1W +1S) of duty of suitable capacity Min. 4 m3/hr and 25 m head , horizontal centrifugal pumps with casing/cover of Cast Iron(CI), impeller SS and shaft of SS, suitable for mechanical packed seal complete with base frame, pump driven by electric motor of suitable kW rating and RPM with IP 55 protection and class F insulation, foundation bolts,. Transferring CTBD effluent from CTBD effluent collection tank to PSF.

-

-

-

... More
Vertical floor mounted mild steel epoxy painted Pressure Sand Filter - 1 Number of suitable size for design flow, provided with an inlet distributor. The vessel is painted externally and internally with epoxy paint with primer with frontal piping & valves, back wash system & filter media etc. complete with standard fittings like cover, pressure gauge at inlet & outlet, sampling valves, rinse drain valve, air vent valve with piping, bolts, nuts & rubber gaskets. Design pressure shall be 1.5 times of operating pressure. Flow rate : 4 M3 / hr Filteration rate : 15 M3/M2/Hr

-

-

-

... More
Vertical floor mounted mild steel Epoxy Painted Activated Carbon Filter - 1 Number of suitable size for design flow, provided with an inlet distributor. The vessel is painted externally and internally with epoxy paint with primer with frontal piping & valves, back wash system & filter media etc. complete with standard fittings like cover, pressure gauge at inlet & outlet, sampling valves, rinse drain valve, air vent valve with piping, bolts, nuts & rubber gaskets. (vendor to submit the Iodine value of the carbon during 1st filling). Design pressure shall be 1.5 times of operating pressure. Minimum Iodine Value of Activated Carbon Media : 900 mg /gm Flow rate : 4 M3 / hr Filteration rate : 12 M3/M2/Hr

-

-

-

... More
UF Feed Pumps : 2 nos. (1W +1S) of Minimum 4 m3/hr and 20 m head, horizontal centrifugal pumps with casing/cover of Cast Iron(CI), impeller SS and shaft of SS, suitable for mechanical packed seal complete with base frame, pump driven by electric motor of suitable kW rating and RPM with IP 55 protection and class F insulation, foundation bolts,. Transferring CTBD Effluent from UF Feed Tank to UF system

-

-

-

... More
ULTRAFILTRATION SYSTEM (Dead end type) complete system which shall minimally comprise of the following processes and services: a) The ultrafiltration system shall be designed for Design flow of minimum 4 m3/hr with adequate provision for membrane protection such as suitable bag filter with housing prior to UF b)Skid mounted Low pressure Membrane Filtration System (include backwash, clean-in-place system, CEB system, pressure measurement, and other ancillary equipment ) c) Membrane System shall be pressure driven. d) Membrane shall be comprising of homogeneous hollow fibre type with nominal pore size of 0.04 μm for removal of bacteria, and particulates including colloids. e) UF Membrane shall be provided with all necessary chemical cleaning facility like CIP System and CEB System as per vendor requirement. 1 dedicated set for CEB / CIP should be be provided consisting of 1 no.Tank – HDPE and 2 nos. Pumps -PP f) Operating pH range 2-11. g) The hollow fiber membranes should be PVDF. j) MOC of central permeate tube, feed & reject port shall be UPVC. j) MOC of Membrane housing shall be FRP. k) Membrane backwash system shall use UF Permeate to remove accumulated particles and maintain a design filtrate production rate. l) The membrane system must include membrane integrity test that is capable of demonstrating the membrane system is achieving a minimum of 4-log removal of particles greater than 2 microns. The membrane integrity test must be fully automated and capable of testing the membrane every 24 hours of operation. Each membrane module must have view glass for integrity test. (1 Set).

-

-

-

... More
UF Backwash Pumps : 2 nos. (1W +1S) of Suitable capacity and head as recommended by Membrane Manufacturer. Horizontal centrifugal type pumps with casing/cover of Cast Iron(CI), impeller SS and shaft of SS, suitable for mechanical packed seal complete with base frame, pump driven by electric motor of suitable kW rating and RPM with IP 55 protection and class F insulation, foundation bolts,. Transferring UF permaete from UF Permeate Tank for backwashing UF system

-

-

-

... More
RO Feed Pumps : 2 nos. (1W +1S) of 10 m3/hr and 20 m head , horizontal centrifugal pumps with casing/cover of Cast Iron(CI), impeller SS and shaft of SS, suitable for mechanical packed seal complete with base frame, pump driven by electric motor of suitable kW rating and RPM with IP 55 protection and class F insulation, foundation bolts,. Transferring UF Permeate from UF Permeate Tank to RO system

-

-

-

... More
Anti-scalant dosing system consisting of solution preparation tank, level indicator and level switches and with anti-scalant dosing pumps electronic diaphragm type of suitable capacity and head. Dosing Tank- 1 No. MOC-HDPE Dosing Pumps – 2 Nos. (1W+1S) MOC- PP

-

-

-

... More
SMBS (Anti-oxidant) dosing system consisting of solution preparation tank with motorised agitator, level indicator and level switches and with anti-oxidant dosing pumps electronic diaphragm type of suitable capacity and head. Dosing Tank- 1 No. MOC-HDPE Dosing Pumps – 2 Nos. (1W+1S) MOC- PP Motorised Agitator- 1 No. MOC- SS 304

-

-

-

... More
pH correction of RO permeate consisting of solution preparation tank with motorised mixer, level indicator and level switches and with alkali dosing pumps electronic diaphragm type of suitable capacity and head Dosing Tank- 1 No. MOC-HDPE Dosing Pumps – 2 Nos. (1W+1S) MOC- PP

-

-

-

... More
RO System-RO system complete with inlet cartridge filter, high pressure pumps (1W+1S), required no. of spiral wound RO membrane elements mounted in pressure vessels, all mounted on a skid. RO system to be designed for min. 55% recovery. Instruments to include Flow meter, pH meter, ORP analyser, conductivity meter at RO inlet pH and conductivity meter and flow meter on the permeate outlet. A flow indicator on the reject line, Pressure switches on the high pressure pump suction and discharge Pressure gauge on the RO inlet and reject. The system should be designed for automatic operation with necessary interlocks as indicated in technical specifications. Capacity: to be designed tohandle feed flow of 200 KLD in 20 hrs operation RO high pressure pumps 2 Nos. (1W+1S) MOC : SS 316 Cartridge filter- 1 No.MOC Cartridge filter: PP Woven Housing : SS 304, Quantity-As per projection, Warranty minimum 3 Years. Skid: SS 304, High pressure piping SS 316 alongwith victaulic couplings Low pressure piping uPVC

-

-

-

... More
Cartridge filter for CIP - 1 No. MOC Cartridge filter: PP Woven Housing : SS 304

-

-

-

... More
CIP system for RO consisting of CIP tank with motorised agitator, CIP pump, piping and hose pipes, flow indicator. All mounted on a movable trolley. CIP Tank: HDPE, CIP pump 2 Nos. (1W+1S) SS 316, Motorised Agitator- 1 No. MOC- SS 304 1 No. trolley MS with FRP coating.

-

-

-

... More
PIPING

-

-

-

... More
All piping (as described below) and isolation control Ball / butterfly valves (Min. PN 10) of required sizes and numbers with all accessories, fittings, supports, clamps, double flanged flexicon rubber expansion joint with rubber gasket as per system pressure, nuts, bolts, washers, fasteners, puddle flanges for all tanks, other flanges, all required type of valves such as NRV's, flow control valves, sampling valves, flow measurement device, butterfly valves, ball valves, globe valves etc., SS 304 screen strainers Y type at suction of clear water pumps, for making the system complete in all respects with anti corrosive protection. Details are as follows:

-

-

-

... More
Butterfly Valve : Cast Iron Wafer type butterfly valves (PN 10) as per IS:13095, with SS disc, SS shaft, SS seating rings, SS internal fastening, EPDM seat, CS external nuts-bolts.

-

-

-

... More
Check Valve : Cast Iron body dual plate wafer type check valve (NRV) (PN 10) with SS disc, SS stem, EPDM seat, spring & pin, SS stem, SS internal fastening, CS external fastening.

-

-

-

... More
PVC Flexible Breaded Hose Pipe : Submerged piping for raw sewage transfer pumps / Submerged piping for diffusers.

-

-

-

... More
Interconnecting pipes with required pipe fittings, control valves, manual valves as per the system design, flange connections, gaskets,GI fasteners, pipe supports etc for making the system completed.

-

-

-

... More
MSEP : All interconnecting piping & Frontal Piping for filters CI for Pump suction and discharge UF System : UPVC RO High pressure piping - SS 316 with Victaulic coupling Low pressure piping - uPVC

-

-

-

... More
GI (Class 'C') : Air grid piping-non submerged & UPVC for submerged Piping

-

-

-

... More
INSTRUMENTS

-

-

-

... More
Capacitance type Level Transmitters in Equalisation Tank, MBR Tank, MBR Permeate Tank, CTBD effluent collection Tank, UF Feed Tank, UF Permeate Tank/RO Feed Tank, RO permeate Tank, RO reject tank with provision for alarm at high level in the tank and alarm as well as tripping of pumps at low level.

-

-

-

... More
Level switches in Sludge Holding Tank, Plant Room Sump, Centrate collection Sump, all Dosing Tanks with provision for alarm at high level in the tank and alarm as well as tripping of pumps at low level.

-

-

-

... More
DO meter in Aeration tanks

-

-

-

... More
Electro- magnetic Flow transmitter with indicator and totalizer ‒ At the discharge of Equalized sewage transfer Pumps ‒ At the discharge of Equalized sewage Bypass Pumps ‒ At the discharge of MBR Permeate Pumps ‒ At the discharge of MBR Backpulse Pumps ‒ At the discharge of Filter Feed Pumps ‒ At the discharge of UF feed Pumps ‒ At the discharge of RO Feed Pumps ‒ At the discharge of RO Permeate Line ‒ Any location wherever necessary as per bidder’s design

-

-

-

... More
Pressure Transmitter at the discharge Backpulse Pumps

-

-

-

... More
DPS across bag filter, Cartridge Filter, RO system

-

-

-

... More
Pressure switch at the suction & Discharge of RO High Pressure Pump

-

-

-

... More
Turbidity meter on the discharge pipe of MBR Permeate Pumps and UF permeate pumps

-

-

-

... More
Flow Transmitter on RO Reject Line

-

-

-

... More
pH Transmitter at discharge of RO Inlet and RO Permeate Line

-

-

-

... More
Conductivity Transmitter at RO Inlet and Permeate Line

-

-

-

... More
ORP analyser with transmitter and controller

-

-

-

... More
Dump valve & Auto valve for RO system

-

-

-

... More
Pressure gauges

-

-

-

... More
If required, Instrument air compressor with an air receiver tank, air filter-dryer and air filter regulator along with instrument air piping and tubing for pneumatically operated valves

-

-

-

... More
PLC PANEL

-

-

-

... More
Complete instrumentation system including PLC for Automatic Operation. Vendor Should provide PLC Logic as required to operate their System. PLC controller with SCADA software system should be integrated with BMS through Open protocol including all necessary accessories, material ,tools takcles required to complete the job in all respects alongwith UPS. BMS compatible with any open communication protocol for 3rd party integration.

-

-

-

... More
ELECTRICAL WORKS

-

-

-

... More
Supply, installation, testing and commissioning of following electro mechanical works and equipments -

-

-

-

... More
ELECTRICAL INSTALLATION FOR SEWAGE TREATMENT PLANT SYSTEM

-

-

-

... More
LT Panel for Sewage Treatment Plant

-

-

-

... More
Design, Engineering, Manufacture, Supply, Commissioning, Documentation of LT Switchgears for STP area as per the scope of work including submission of relevant data, inspection and testing at factory works, packing, transportation from MANUFACTURER works to site, including transportation from store/yard to site at the place of installation, handling equipment , unpacking, assembly, including mounting and wiring of loose parts supplied by equipment vendor, interconnection of shipping sections and requisite inter-panel wiring between shipping sections, including supply of wiring material, installation on foundations or fixing to wall or steel structures, aligning, levelling, grouting, testing, and calibration of relays and metres etc., including all labour and materials, as per approved drawings, specification of this tender and directions of PMC/Employer The panel incommer shall not exceed the 400A of MCCB & 25 numbers of outgoing including spare feeder.

-

-

-

-

-

-

... More
Supply, Installation testing & commissioning of local push button with all necessary accessories including all labour and materials required for STP system as per approved drawings, specification of this tender and directions of PMC/Employer

-

-

-

... More
LT Power & Control Cable

-

-

-

... More
Supply, laying,testing and commissioning of power,control & communication cables along with cable tray and supports of required size for STP System as per the scope of work. Cables shall be laid in cable trays, hume pipe/cable Gallery supported on structure/pull through pipes including pipes, supply and fixing of Aluminium strip number tags, supply and fixing of GI saddles and saddle bars, supports including anchor fastener,conduits etc. including transportation from owners stores to site. Unpacking, with all labour and material as per specification of this tender and directions of PMC/Employer. (Suitable size of IC/OG cables shall be selected by the contractor as per Load details.)

-

-

-

... More
Earthing System

-

-

-

... More
Supply, installation and connection of required size of earthing strip required for STP area as per the scope of work including welding at joints, providing anti-corrosive paint or bitumen for welded portion, clamping and necessary hardware for connecting, etc., including all labour and materials,as per specification of this tender and directions of PMC/Employer (Earthing will be Pipe earthing with 3000mm depth &40 mm Dia pipe, Strip size will be decide as per the fault level calculation.)

-

-

-

... More
Supply and laying of 1000mm wide safety insulation mats of 415V,required for HVAC system grades required for maintenance of electrical equipment in substation, including cutting to required shape as per IS

-

-

-

... More
ADDITIONAL ITEMS /OTHER WORKS / SYSTEM

-

-

-

... More
Any other items, works, systems not specifically mentioned above but necessary for satisfactory performance of the system shall be con

-

-

-

... More
SOLID WASTE MANAGEMENT SYSTEM (SWM)

-

-

-

... More
Mechanized composter (Invessel Composting)

-

-

-

... More
Design,Supply, Construct, maintain of Mechnized Composting System of capacity 1000 kg/day as per technical specification mentioned in tender document.

1

-

-

... More
Garbage Stroage Bins of capacity 600 liters HDPE/PVC Storage bins with Wheel mounted or trolley mounted. Waste Garbage Bins shall be colour coded & Heavy Duty Sunproof Tight-fitting, overlapping lid to help contain odors. Colour : Green, Blue & Yellow

6

-

-

... More
Garbage Stroage Bins of capacity 120 liters HDPE/PVC Storage bins Waste Garbage Bins shall be colour coded & Heavy Duty Sunproof Tight-fitting, overlapping lid to help contain odors. Colour : Green, Blue & Yellow

4

-

-

... More
Tool Box: Containing several tools for repairing of electrical and equiments.

1

-

-

... More
Segregation Table As per vendor design to handle the required capacity of daily waste made of Stainless steel

1

-

-

... More
Weighing Scale Electronic Weighing Scale, Capacity 100 Kg

1

-

-

... More
Bag packing Machine: Small bag packing machine to pack compost bag, sutable to pack 25-50 kg bag

1

-

-

... More
Manual Handling Trolley Stainless Steel Platform Trolley Load Capacity 100 to 150 kg Strong, rigid, steel handle for secure maneuvering of loads 4 ball bearing wheels for easy and safe steering. Compact design for easy storage.

1

-

-

... More
ELV SYSTEM WORKS

-

-

-

... More
INTELLIGENT FIRE ALARM SYSTEM

-

-

-

... More
Supplying, installation, testing & commissioning of micro processor based Intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories. The panel shall be compatible for IBMS system with open protocol Modbus over IP complete as per specifications. Ten Loop Panel

3

-

-

... More
DVC (Digital Voice Command) system for fire fighters telephone. Supplying, installing, testing and commissioning of Digital Voice Command Extended Memory and Keypad. The DVC Should support 2 ways Communication for Fire Fighters.The Fire Fighters Telephone System shall be capable of having minimum 30 Telephones in conference in multiple FFT Risers. This has to be installed in one of the above 10 loop fire alarm panel. This inclusive of necessasy accessories, amplifiers (suitable for fire fighters telephone quantity mentioned in this BOQ), modules & should be seamless integration with all fire alarm panels. This should be the same make of main fire alarm panel. Vendor shall consider the suitable size cabinet of fire alarm panel to accomodate this DVC equipments

1

-

-

... More
Supplying, installation, testing and commissioning of Central Graphical fire alarm management system to centrally monitor and operate the fire alarm system complete as required

1

-

-

... More
Supplying, installation, testing and commissioning of Addressable Active Repeater Panel consists of display board having 160 Character Display with Touch key pad, Mother board which will have 64 Bit Processor, Inbuilt RS-485 Networking Circuit for peer to peer networking.

2

-

-

... More
Supplying, installation, testing and commissioning of Intelligent / Analog Addressable Detectors - Multi Sensor - Heat Cum Smoke Detector with mounting Base with Binary coded address setting / Rotary Switches / Electronic codec programable address setting. Dual LED’s for 360° visibility complete with mounting base complete as required, with Back box, Glands

1844

-

-

... More
Supplying, installation, testing and commissioning of Response indicator for all detectors located above false ceiling / Below False Floor complete with all connections etc as required with Back box, Glands

339

-

-

... More
Supplying, installation, testing and commissioning of Fault Isolator Module capable of monitoring shorted loop circuit and automatically restore communications as required with Back box, Glands

152

-

-

... More
Supplying, installation, testing and commissioning of Intelligent Addressable Heat Detector / Thermal Detector with base with Binary coded address setting / Rotary Switches / Electronic codec programable address setting. Dual LED’s for 360° visibility complete with base as required Back Box, Glands

5

-

-

... More
Supplying, installation, testing and commissioning of addressable Fire Control Module / Control Relay Module for AHU / CSU / HRW / TFA Tripping, Access Control Door Tripping, Smoke Exhaust Fan activation, Fire Damper Activation / PA System Activation etc complete as required with back Box, Glands

440

-

-

... More
Supplying, installation, testing and commissioning of addressable Firefigher Phone Control Module for Firefighter Telephone Jack to activate the Firefighter Telephone functional, complete as required

30

-

-

... More
Supplying, installation, testing and commissioning of Intelligent Addressable Beam Detector (5-50mtrs) with Binary coded address setting Dual LED’s for 360° visibility comprising of 4 wire system with Infra-Red Emiter and Receiver in a single housing and single reflector platecomplete with emitter and received including connections with remote test features etc complete as required with back box, Glands. The rate shall inclusive of Response Indicator. Also the rate shall inclusive of External dedicated 24VDC Power Supply Unit with Battery backup in case the Beam Detector shall not have loop pwered. Power Supply Unit shall be provided with necessary Enclosures.

5

-

-

... More
Supplying, installation, testing and commissioning of Intelligent Addressable Duct Detector including suitable Photo detector complete with base as required with back box , Glands

90

-

-

... More
Supplying, installation, testing and commissioning of Intelligent Addressable Manual Pull Station Dual Action type, complete as required with back Box, Glands.

176

-

-

... More
Supplying, installation, testing and commissioning of addressable horn cum strobe complete as required with Back Box, Glands

176

-

-

... More
Supplying, installation, testing and commissioning of fire fighter telephone handset complete as required Back Box, Glands

30

-

-

... More
Supplying, installation, testing and commissioning of intelligent interface Gateway Module Unit Modbus / BACNet Protocol i.e. supplying communication links between building management system and fire alarm control panel complete as required.

1

-

-

... More
Supplying, installation, testing and commissioning of fire fighter telephone jack complete as required.

30

-

-

... More
Supply and laying of FRLS PVC insulated 2 core 1.5 sq.mm. Armoured Copper Cable on ceiling / wall using fixing accessories like screws, plug, clamps, etc., as per standard methods and as directed by the PMC/Employer.

33986

-

-

... More
Supply, installation, fixing, testing and commissioning of Analogue Addressable Monitor module with back box (1.6mm thick RED colour) operating at 24V DC, 2A, rated at 230V, provided withSPDT contact with required fixing accessories

254

-

-

... More
Supply and installation of MS Powder coated Trunking 300 x 50 mm x 1.6mm with cover & fixing suppports etc as required (Cable dressing for Fire & PA panel)

30

-

-

... More
Supply and installation, testing and commissioning of Power Supply : 24VDC Power Supply with 5 amp rating, having LED indications for Power supply ON, Battery Fail, Battery Charging, battery back up etc. (inclusive of Battery ckt & shall have inbuilt charger circuit, 2x12V 7.1AH Battery and enclosure)

15

-

-

... More
Supply, installation, testing and commissioning of Client workstation Intel core 9th Generation Intel Core i9 Processor by latest generation or better, 16GB DDR3 RAM, 64-bit operating system, 1TB SSD for OS and Security Center applications, with a minimum of 16 GB of free disk space to install the Security Center client application, 1TB SATA Hard disk with 7200rpm, GbE network interface card, DVD-RW standard keyboard & Mouse with Dual NVIDIA GeForce RTX 2080 video card with 21" FULL HD LED MONITOR. Minimum 4 HDMI,1 parallel, 8 USB 2.0, 1 serial, 2 Ultra ATA/100, 2optional IEEE1394, 1 USB Keyboard, 1 USB Mouse, 1 video, 1 Microphone jack, 1 Line-in jack, 2 x 1GBPS RJ-45 Interface Port Note: The Configuration mentioned is only Minimum requirement. Vendor shall be consider as per the Fire Alarm System OEM recommendations, in case of higher configurations shall be required to enable the functional requirements and consider the cost for the same & quote accordingly. Bidder shall be considered the specified configuration if the Fire Alarm System OEM do not have an objection. No deviation shall be accepeted.

1

-

-

... More
ASPIRATION SMOKE DETECTION SYSTEM

-

-

-

... More
Supplying, installation, testing & commissioning of intelligent aspiration detector for area coverage of minimum 5000 sq.ft complete as required.

1

-

-

... More
Supply, installation, testing and commissioning of Electronic Hooter / Sounder providing on wall using fixing accessories like screws, plug, clamps and etc., as per standard methods and as directed by the PMC/Employer

1

-

-

... More
Supply, Installation, testing, commissioning of 25 mm outer dia CPVC Pipe with end caps including making air sampling opening of appropriate dia on appropriate interval and all accessories as required, (rate for area protected in sq.m) - IBMS Server Room - 60 Sq.Mtr

60

-

-

... More
WATER LEAK DETECTION SYSTEM

-

-

-

... More
Supplying, installation, testing and commissioning of Water Leak Detection sensing cables with end of line connectors along with Hold-down clips at every 0.3M interval.

40

-

-

... More
Supplying, installation, testing and commissioning of Addressable Water leak detection panel including battery backup (12 hr) as per the below specification inclusive of all necessary accessories - Inbuilt with Modbus for BMS integration - Relay output for Alarm and fault - 230V AC 5A - LED Indications (power ON, Alarm, fault etc) - 100 event log - Wall mount type with enclosure and PSU with battery backup

1

-

-

... More
Supplying, installation, testing and commissioning of Water Leak Detection Module Water leak tape interface module with display, enclosure, PSU with battery backup and alarm out for Hooter, relay out for fire integration as per specification

1

-

-

... More
Supply, installation, testing and commissioning of Electronic Hooter / Sounder providing on wall using fixing accessories like screws, plug, clamps and etc., as per standard methods and as directed by the PMC/Employer

1

-

-

... More
RODENT REPELLENT SYSTEM

-

-

-

... More
Supplying, installation, testing and commissioning of Master Console panel including support bracket (12 Transducer per console) with modbus for BMS integration

6

-

-

... More
Supply, installation, testing & commissioning of transducers, circular ceiling mounted type, having power output of 800mW/transducer. Quoted rate shall include necessary mounting clips / clamps, MS back box etc. vide technical specification and with a coverage area of ceiling/ floor void- 150 sq.ft. Room void – 300 sq.ft respectively.

68

-

-

... More
Supplying, installation, testing and commissioning of 1 pair flexible 14/40 SWG Specially coated wire, PVC sheathed Cable

476

-

-

... More
Supplying and fixing of following sizes of M.S steel conduit along with accessories in surface / recess including painting in case of surface conduit or cutting the wall and making good the same in case of recessed conduit as required 25 mm

476

-

-

... More
PUBLIC ADDRESS SYSTEM

-

-

-

... More
Supply , Installation, Testing & Commissioning of ceiling loudspeaker of 6 W, 100 V line speaker with fire rated dome having the following specifications : - Power: 9W or better, - Rated Power: 6Watts or better, - Power Tapping: 6/3/1.5W or better - Effective frequency range (-10 dB): 57 Hz to 24KHz - SPL at rated power (6W at 1 m) 94dB or better, With other neccessary accessories to make system complete as per specification/drawings Note: The rate shall inclusive of back box for True Ceiling Speaker wherever applicable. The Quantification of the True Ceiling Speaker shall be quantified as per the tender drawing.

336

-

-

... More
Supply , Installation, Testing & Commissioning of wall mount loudspeaker of 6 W, 100 V line speaker having the following specifications : - Max Power: 9W or better, - Rated Power: 6Watts or better, - Power Tapping: 6/3/1.5W or better - Effective frequency range(-10 dB): 230 Hz to 24KHz - SPL at rated power (10W at 1 m) 103dB or better, With other neccessary accessories to make system complete as per specification/drawings Note: The rate shall inclusive weather proof cabinet for Outdoor wall mount 6W Speaker. The Quantification of the True Weather Proof Speaker shall be quantified as per the tender drawing.

212

-

-

... More
Supply , Installation, Testing & Commissioning of Wall mount 15W full-range Speaker, with following specifications and as directed by PMC/Employer. - Woofer: 4” & Tweeter: 1” or better - Housed in a fire rated ABS plastic metallic grille - Maximum SPL 94.3dB or better, - Sensitivity 82.5dB or better, - Operating Temperature of -25ºC ~ +80ºC - Transformer with 8 Ohm pass- through. - Transformer taps: 100V: 15 W, 7.5 W, 3.75 W & 1.8 W, 8Ohm. - Frequency response (-10 dB) 83Hz - 23 kHz. - Coverage Angle(1Khz) Horizontal 180° Vertical 186° or better - IP-65 as per IEC268-5 WIth other neccessary accessories to make system complete as per specification/drawings

2

-

-

... More
Supply, installation, testing & commissioning of Master 16 Zone Digital Voice Alarm Network Controller with 1000W built in amplifier. The controller shall have a compatibility to expand up to 256 Zones. Digital Voice Alarm Network Controller should be able to comply with the following requirement a. Pre-recorded messages (up to 255). b. 1000 W RMS power unit and control of Sixteen Speaker Zones. c. 16 audio inputs (line)Control inputs and control outputs for connection to external systems d. Supervision of the amplifier, the speaker lines, the emergency microphone, the pre-recorded messages, e. Possibility of redundant connection with secondary amplifiers and microphone desks, up to 600 m All are digital PA System. Analog system shall not be accepted. The rate shall inclusive of all necessary accessories line communication cables from Controller to Amplifier, Amplifier to Microphone Console etc.

1

-

-

... More
Supply, installation, testing & commssioning of 24 programmable keys for zone selection, music, messages, and a selection key for all zones. Distance to the amplifier up to 600 m, with the possibility of redundant connection. It has volume adjustment, external mic / line input, possibility of PTT (push-to-talk) operation ..

2

-

-

... More
Supply, installation, testing & commissioning of 1 x 500 W Power Amplifier @ 4/8Ω 70/100V, Class D shall have following features & shall comply to technical specifications 1. Protected against overload, short circuits and over-heating 2. Built-in fan with temperature-controlled rotation speed control, with airflow from front to back of device.

6

-

-

... More
Supply, installation, testing & commissioning of 4 x 250 W Power Amplifier @ 4/8Ω 70/100V, Class D shall have following features & shall comply to technical specifications. 1. Protected against overload, short circuits and over-heating 2. Built-in fan with temperature-controlled rotation speed control, with airflow from front to back of device.

2

-

-

... More
Supplying, installation, testing and commissioning of Volume controller to be choosen max control of 20W for one speaker (near call station)

9

-

-

... More
Supplying, installation, testing and commissioning Rack Mounted Multimedia Player as per specifications

1

-

-

... More
Supply and laying of 2 Core - 1.5 sq.mm Armoured Speaker Cable on ceiling / wall using fixing accessories like screws, plug, clamps, etc., as per standard methods and as directed by the PMC/Employer.

10278

-

-

... More
ACCESS CONTROL SYSTEM

-

-

-

... More
Master Controller: Supply ,Installation ,Testing & Commissioning of TCP-IP Access Control Panel with onboard OSDP support, UL-294 Recognized, FCC Part 15 Class A, CE Compliant, RoHS, NIST Certified Encryption, 240,000 cardholder capacity, 50,000 transaction buffer, Natively supports for up to 4 readers and 2 doors. Expands to support up to 64 readers and openings. Data Input TTL compatible, F/2F or 2-wire RS-485. Security &  network IPv6, Host communications protected by TLS 1.2/1.1 or AES-256. FIPS 140-2 user of OpenSSL. Temperater to 85 °C storage, 0 to 70 °C operating temperature, along with Enclosure with UL Listed 12V 5Amp or 24V 2.5 Amp SMPS DC Power Supply Unit, highly regulated and spikes free terminal voltage and heavy sourcing current for regulated terminal voltage etc. The rate shall inclusive of all necessary Mounting Enclosures with Battery Charger, 12V/7AH Battery, mounting Accessories, Cable Managers etc. No addidional cost shall be provided seperately by Employer for any accessories. Enclosure Colour shall be taken prior approval before procurement and the same shall not inwarded with out prior approval.

6

-

-

... More
Reader Module: Supply, Installation, Testing & Commissioning of 4 reader interface control panel with onboard OSDP support, UL-294 Recognized, FCC Part 15 Class A, CE Compliant, RoHS, NIST Certified Encryption, supports 4 readers and 2 doors. Data Input TTL compatible, F/2F or 2-wire RS-485. Security &  network IPv6, Host communications protected by TLS 1.2/1.1 or AES-256. FIPS 140-2 user of OpenSSL. Temperater to 85 °C storage, 0 to 70 °C operating temperature, along with Enclosure with UL Listed 12V 5Amp or 24V 2.5 Amp SMPS DC Power Supply Unit, highly regulated and spikes free terminal voltage and heavy sourcing current for regulated terminal voltage etc

57

-

-

... More
Supply, installation, testing & commissioning of Multi-Technology contactless smart card reader, Mullion mount, IP65, Converge multiple credential technologies onto one reader platform with support for Smart and Mobile credentials, Bluetooth, OSDP, encrypted communication between credential and reader, supports Secure Identity Object on Seos, iClass SE/SR, Mifare DESFire EV2/Ev3 and Mifare Classic , Certification: UL 294/cUL, FCC certification CE including RoHS II,BIS, EAL 5+ certified secure with 2.5mm thick SS front plate as per specification suitable for mounting on metal surface/metal frames or wooden frames wall or as required based on site conditions including all accessories.UL Certified.

140

-

-

... More
Supply, installation, testing & commissioning of Supply, installation, testing and commissioning of Biometric Finger Reader with multi spectral imaging technology for consistent read performance,IP67, supports Secure Identity Object on Seos, iClass SE/SR, Mifare DESFire EV2/Ev3 and Mifare Classic, BLE and NFC mobile ID's, support 5000 finger print on device, should support 1:N and template on card 1:1,should support OSDP and Weigand communication, Certification: BIS, UL 294/cUL, FCC certification, CE,, EAL 4+ certified secure element with all accessories required at site to complete the work as per technical specification with 2.5mm thick SS front plate as per specification suitable for mounting on metal surface/metal frames or wooden frames wall or as required based on site conditions including all accessories.UL Certified.

17

-

-

... More
Supply, installation, testing & commissioning of Supply, installation, testing and commissioning of QR Code Reader as per the technical specification. The QR Code reader shall install inside the Swing Barrier for Visitor QR Code Access. QR Code Reader OEM shall co-ordinate with Swing Barrier OEM and provide the necessary provisions to mount the device accordingly.

4

-

-

... More
Supply, installation, testing and commissioning of 8K contactless smart card support 13.56 Mhz, support multi-layered trusted management of secure identities using the portable Secure Identity Object data model, supports AES 128 bit cryptographic algorithm for data protection, printable cards with corporate 1000 programming to avoid duplication.with Lanyard to hold the cards as per specification.

1000

-

-

... More
Supply, installation, testing and commissioning of Web Based Enterprise level Application for Access Control Management and Time Attendance Application with ulnlimted no. of users/card holders.GUI, Antipass back, Reports in Inbox, Unlimited Users, Door Scheduling, Unlimited logins, Time base access and alerts. As per Cyber Security guidelines Grey Web Box Web Penetration tetsing as per ISSAF;OWASP Top 10 2013 and 2017;SANS TOP 25;OWASP Top 10 2021 and CER In Standards. (VAPT Certified). It should include following AI modules. a. CCTV Video Integration - Video Management System Plug In from single server, for CCTV Popups, Live stream, Historical data analysis, Etc (VMS Application OEM to share API/ SDK & support for the integration) b. ACS & TA Integration Module with ERP/ HRMS at API Level. c. Credential Management Module for Biometric Template Management (Enrollment, Distribution Etc), Badge Designing, Printing Etc. d. Interface Software / Hardware to integrate with the Lift Destination Control System (DCS) control system with Access control System as specified in the Tender Specifications.(Lift OEM would provide the API/ SDK & Simulator for the test enviroment) e. Visitor Managemnt Client application (Lobby Application/ on Android Tab), shall be comaptible to Integrate with web camera, pass printer, signature pad, document scanner, visiting card scanner, Designing Pass and ability to change to Visitor Self help Kiok.

1

-

-

... More
Supply, installation, testing and commissioning of Access Control System Server: Includes Server, Windows Server Standard, SQL Server Standard. Intel Xeon Silver 3104 Processor, 8 MB L3 Cache, 6 Cores, 6 Threads 3 x 8GB RDIMM, 2666MT/s 1 x 1TB 10K RPM SAS 2.5in Hot-plug Hard Drive 2GB Network Card Windows Server 2016/2019 Standard , 104, 12 function key DD, 21" LCD Monitor, Wireless Mouse, USB Keyboard, CD/DVD Combo Writer, TCP/IP Connection. Note: The Configuration mentioned is only Minimum requirement. Vendor to consider as per OEM recommendations in case of higher configurations shall be required as per project functional requirements and the bidder to consider the cost for the same & quote accordingly. The bidder needs to consider the same configuration if OEM will not have an objection for the mentioned specifications. No deviation shall be accepeted. The Server shall be Balde Type and its should be Rack mounted. Tower type shall not be accepted

1

-

-

... More
Supply, installation, testing and commissioning of Client workstation (Access Control System Client Workstation) Intel core 9th Generation Intel Core i9 Processor by latest generation or better, 16GB DDR3 RAM, 64-bit operating system, 1TB SSD for OS and Security Center applications, with a minimum of 16 GB of free disk space to install the Security Center client application, 1TB SATA Hard disk with 7200rpm, GbE network interface card, DVD-RW standard keyboard & Mouse with Dual NVIDIA® GeForce® RTX 2080 video card with 21" FULL HD LED MONITOR. Minimum 4 HDMI,1 parallel, 8 USB 2.0, 1 serial, 2 Ultra ATA/100, 2optional IEEE1394, 1 USB Keyboard, 1 USB Mouse, 1 video, 1 Microphone jack, 1 Line-in jack, 2 x 1GBPS RJ-45 Interface Port (Note: The Configuration mentioned is only Minimum requirement. Vendor shall be consider as per the Access Control System Software OEM recommendations, in case of higher configurations shall be required to enable the functional requirements and consider the cost for the same & quote accordingly. Bidder shall be considered the specified configuration if theAccess Control System Software OEM do not have an objection. No deviation shall be accepeted.)

1

-

-

... More
Supplying, installation, testing and commissioning of Single Leaf EM Lock 600LBS in each Leaf Electromagnetic Lock with required mounting brackets for single door as per the tender specifications

45

-

-

... More
Supplying, installation, testing and commissioning of Double Leaf EM Lock 600LBS in each Leaf Electromagnetic Lock with required mounting brackets for double door as per the tender specifications

61

-

-

... More
Supplying, installation, testing and commissioning of surface / flush mounted Magnetic Contact (Door position sensor) for access controlled doors as per the tender specifications

223

-

-

... More
Supplying, installation, testing and commissioning of Local scare alarm with required wiring between LSA & door contacts (For fire exit doors). Rate shall inclusive of door contacts

28

-

-

... More
Supplying, installation, testing and commissioning of panic bar for fire exit doors (double leaf) as per Specification (For fire exit doors, Panic BAR shall be RED in color).

28

-

-

... More
Supplying, installation, testing and commissioning of 4 core 1.0 Sq mm Un Armoured Shielded, Multistanded Copper Conductor, PVC sheathed Cable with accessories for connecting controller to Lock & door position sensors, Buzzer, BGU, Pushbutton as per the tender specifications

8175

-

-

... More
Supplying, installation, testing and commissioning of 2 core x 1 Sq mm Un Armoured Shielded, Multistanded Copper Conductor, PVC sheathed Cable with accessories

8597

-

-

... More
Supplying, installation, testing and commissioning of Buzzer for access controlled doors as specified in the Tender Specifications

106

-

-

... More
Supplying, installation, testing and commissioning of EDR (Emergency Door Release)

106

-

-

... More
Supplying, installation, testing and commissioning of Egress Switch Units with back box and accessories

3

-

-

... More
Supplying, installation, testing and commissioning of MS Powder coated Trunking 300 x 50 mm x 2mm with cover & fixing suppports etc as required for panel dressing

225

-

-

... More
Supplying and fixing of following sizes of Medium Class PVC conduit along with accessories in surface / recess including cutting the wall and making good the same in case recessed conduit as required 25mm PVC Conduit.

11612

-

-

... More
Supplying, installation, testing and commissioning of X-Ray Single Generator Indoor Bagage Scanner with following technical parameters. Tunnel Size: Min 600 mm (W) x 400 mm (H) or Better, Dimensions: Length: Min 2000 mm or Better, Height: Max 1300 mm or Better. Single view of 160KV high energy XBS which provides steel penetration of 34mm Steel block and wire resolution of 38-AWG. 2 built-in Full HD cameras which helps to monitor the Tunnel Entry & Exit. Software with Inbuilt Artificial Intelligence tool that has 24 types of items to display the Scanned images with AI overlay. Single Screen that displays both Scanned images and video surveillance of Fisheye camera simultaneously. Complete with 0.5 meter Discharge SS Tables with dedicated computer for Monitoring, Image storage and archiving with necessary software. Along With Dual Core Processor at min 3.6 GHz, 8GB RAM, 4TB Harddisk, With Wired Mouse & Customised Keyboard with Emergency stop function, Linux OS and CMS to be incorporated for Centralised monitoring at the premises. Min 1 million images storage along with video recording of Full HD camera, Threat image protection (TIP) enabled in the software with 100 knives, 100 explosives, 100 guns to be loaded in the TIP library which enables the operator to active during security check. HIT, MISS & FALSE Alarm features must be included with different colour code as Green for HIT, Red for MISS and Yellow for FALSE alarm to be enabled in the software. Daily reports to be generated for TIP along with date, time, screener particulars and number of bags screened. Should comply with NABL, CE, FDA, ROHS, FCC, ISO, QCI, NSIC, BS EN 60204-1:2018, EN 61000-6-2-2005, EN 61000-6-3:2007, EN ISO 12100:2010

1

-

-

... More
Supplying, installation, testing and commissioning of Door frame metal detector (DFMD) with Dual side detection, 18 overlapping detector Multi-zones, Displaying panel, Indication of alarm areas, Adjustable area of sensitivity, Two Way operation, Static counting (Directional Counter - In, Out, Net and Alarm), Battery backup 6 to 8 hours. Shall be compatible to integrate with Barriers. Should comply with NABL, CE, FDA, ROHS, FCC, ISO, QCI, NSIC, BS EN 60204-1:2018, EN 61000-6-2-2005, EN 61000-6-3:2007, EN ISO 12100:2010

2

-

-

... More
Supplying, installation, testing and commissioning of High Speed Swing Barrier of (3+1) lane configuration, flaps made of transparent acrylic with 10 mm thickness, RGB indication, Clear passageway, Indoor, opening / closing time of 0.2 seconds minimum. The housing and the base columns shall be made of SS304 with semigloss smooth finish. The barrier shall be equipped with Servo motor and controlled in both directions. In the event of a power failure, both directions shall be freely accessed, Automatic reset upon resumption of power supply. The dimensions shall be Max of 100mm width or better, Max of 1400mm length or better, min 600mm height or Better and the passage width of ~600mm for Normal lane & ~900mm for wide lane. It shall be above 5 million cycles with provisions to mount Smart Card Reder & QR Card Reader, power supply module, wiring & necessary components. It shall Compatible for Integration with Access control & CCTV system. Should comply with NABL, CE, FDA, ROHS, FCC, ISO, QCI, NSIC, BS EN 60204-1:2018, EN 61000-6-2-2005, EN 61000-6-3:2007, EN ISO 12100:2010

2

-

-

... More
Supply, Installation, Testing and Commissioning of Boom Barrier of 3 meter wide with power supply and necessary manual control components. Barrier should operate with 24V Servo motor not less than 5 million cycles. Shall be suitable to control through access control system & Compatible for Integration with CCTV System, Perimeter security system. Barrier arm with LED light and Red reflective strips and to provide accessories such as Wireless remote, Push button, Loop detector, Dual eye Photocell, light with buzzer and boom resting post. Should comply with NABL, CE, FDA, ROHS, FCC, ISO, QCI, NSIC, BS EN 60204-1:2018, EN 61000-6-2-2005, EN 61000-6-3:2007, EN ISO 12100:2010

4

-

-

... More
Supply, Installation, Testing and Commissioning of Boom Barrier of 1.5 meter wide with power supply and necessary manual control components. Barrier should operate with 24V Servo motor not less than 5 million cycles. Shall be suitable to control through access control system & Compatible for Integration with CCTV System, Perimeter security system. Barrier arm with LED light and Red reflective strips and to provide accessories such as Wireless remote, Push button, Loop detector, Dual eye Photocell, light with buzzer and boom resting post. Should comply with NABL, CE, FDA, ROHS, FCC, ISO, QCI, NSIC, BS EN 60204-1:2018, EN 61000-6-2-2005, EN 61000-6-3:2007, EN ISO 12100:2010

3

-

-

... More
Supplying, installation, testing & commissioning of Under Vehicle Surveillance Systems (UVSS) with 2D Area scan camera and necessary work station, software etc. With loop sensor accessories Complete with all Mounting Accessories for Entry Gates Comprising of following Equipment. i. Main Cameras shall give composite image and shall be a high quality, color 2D AREA SCAN, GigE type, with minimum 4 MP resolution or above, attached with wide Lens. Support high vehicle speed, up to 40km / hr in forward and upto 16km / hr in backward. ii. Loop Based Sensors to activate the systems on vehicle arrival & its speed estimation and de-activate after clearance of it. iii. Server Application Software for Vehicle Scanning as well as Auto Number Plate Recognition; shall be loaded on Central Application Management Server hardware provided by vendor as per required specifications. iv. Industrial grade PC with i7 processor, 8GB RAM, 2TB HDD along with 128 SSD for better operation and 21" IPS monitor. v. Client Application Software Vehicle Scanning as well as Auto Number Plate Recognition; shall be Pre-loaded on a PC provided by vendor of required Specs. vi. Mechanical Housing & Protective Structure: All-weather resistant Steel housing for the Cameras (IP-67); completely "Flush to the ground. The rate shall include all required Civil work, Pipes & Conduit work, Electrical and pole work. The equipment should comply with NABL, CE, FDA, ROHS, FCC, BIS, ISO, QCI, NSIC, BS EN 60204-1:2018, EN 61000-6-2-2005, EN 61000-6-3:2007, EN ISO 12100:2010.

2

-

-

... More
Supply, Installation, Testing and Commissioning of Way Finder application: Way finder comes with a 55” interactive display comes with a stand that is suitable to position it in any environment. The installation shall be done by Contractor. The features of the application will be as follows: Pedestal prebuilt mountable stand. Application will have user-friendliness without knowledge on coding. Integration and dynamic data fetched from current CRP application. Live Editing capabilities of customer or client data. Information directory: Find details through keyword search Amenities directory: Find facilities by category aby category and name. Capability to scan and go using mobile app via mobile browser. Ability to work without internet. Work off-line and sync with sever once the connection is restored. Ability to promote a product or company to generate addition revenue or pass general information to visitors. Facility to change destination names, logos, descriptions, and promotions. Interactive facility like touch, zoom and rotate functionality will be made within the limits of the interactive display capabilities. Integration with CRP. View on mobile with QR Scan.

2

-

-

... More
PERIMETER INTRUSION DETECTION SYSTEM (PIDS)

-

-

-

... More
Supplying, installation, testing and commissioning of PIDS Controller with all necessary accessories for mounting the same as per the technical specification.

11

-

-

... More
Supplying, installation, testing and commissioning of Vibration Transducers with all necessary accessories for mounting the same as per the technical specification.

122

-

-

... More
Supplying, installation, testing and commissioning of PIDS Software as per the technical specification.

1

-

-

... More
Supply, installation, testing and commissioning of PIDS Operator / Monitoring workstation Intel core 9th Generation Intel Core i9 Processor by latest generation or better, 16GB DDR3 RAM, 64-bit operating system, 1TB SSD for OS and Security Center applications, with a minimum of 16 GB of free disk space to install the Security Center client application, 1TB SATA Hard disk with 7200rpm, GbE network interface card, DVD-RW standard keyboard & Mouse with Dual NVIDIA® GeForce® RTX 2080 video card with 21" FULL HD LED MONITOR. Minimum 4 HDMI,1 parallel, 8 USB 2.0, 1 serial, 2 Ultra ATA/100, 2optional IEEE1394, 1 USB Keyboard, 1 USB Mouse, 1 video, 1 Microphone jack, 1 Line-in jack, 2 x 1GBPS RJ-45 Interface Port (Note: The Configuration mentioned is only Minimum requirement. Vendor shall be consider as per the Parking Guidance System Software OEM recommendations, in case of higher configurations shall be required to enable the functional requirements and consider the cost for the same & quote accordingly. Bidder shall be considered the specified configuration if the Parking Guidance System Software OEM do not have an objection. No deviation shall be accepeted.)

1

-

-

... More
Supply & laying of 4C x 1 sq mm Flexible Multistrand cable for signal / power as per specification. (from Sensor to sensor & controller) in PVC Conduits on surface. Burried Cable laying shall be carried in DWC HDPE Pipe. The rate shall inclusive of necessary PVC Conduits and other accessories.

1016

-

-

... More
Supply & laying of 3C x 1 sq mm Flexible Multistrand cable for signal / power as per specification. (from Sensor to sensor & controller) in PVC Conduits on surface. Burried Cable laying shall be carried in DWC HDPE Pipe. The rate shall inclusive of necessary PVC Conduits and other accessories.

1016

-

-

... More
Supplying and Laying of following Size DWC HDPE pipe ISI Marked along with all accessories like socket, bend, coupler etc., confirming to IS 14930 Part II complete with fitting, cutting and joining etc., direct in ground (750mm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required 63mm dia (OD-63mm & ID-51mm Nominal) Note: OD - Outer Diameter & ID - Inner Diameter

1016

-

-

... More
IP CCTV SURVEILLANCE SYSTEM

-

-

-

... More
Supply, Installation, Testing and Commissioning of 5MP resolution Varifocal lens IR Dome camera; 1/2.8" CMOS or better; 5MP (2592x1944) resolution, 30fps; Color : 0.07Lux (F1.3, 1/30sec), B/W : 0Lux (IR LED On); 3.2 ~ 10 mm (3X) motorized varifocal; IR viewable length: 30m (98.42ft); DC auto iris,; Day & Night (ICR), WDR (120dB); BLC, WDR, SSDR; H.265, H.264, MJPEG, Minimum 3Nos. individually configurable simultaneous streams in H.265 @ 2592 x 1944 & 30 Fps or better supported;Audion in and out Micro SD/SDHC/SDXC minimum memory 1 slot (Min. 256 GB or higher in each) rate shall inclusive of 256GB SD/SDHC/SDXC. IPv4, IPv6, TCP/IP, UDP/IP, RTP(UDP), RTP(TCP), RTCP, RTSP, NTP, HTTP, HTTPS, SSL/TLS, DHCP, FTP, SMTP, ICMP, IGMP, SNMPv1/v2c/v3(MIB-2), ARP, DNS, DDNS, QoS, UPnP, Bonjour, LLDP, CDP, SRTP, (TCP, UDP Unicast), IP66, IK10. Other technical detail shall be satisfied / complied as per the technical specifications.

274

-

-

... More
Supply, Installation, Testing and Commissioning of 5MP resolution Varifocal lens IR Bullet camera; 1/2.8" CMOS or better; 5MP (2592x1944) resolution, 30fps; Color : 0.07Lux (F1.3, 1/30sec), B/W : 0Lux (IR LED On); 3.2 ~ 10 mm (3X) motorized varifocal; IR viewable length: 30m (98.42ft); DC auto iris,; Day & Night (ICR), WDR (120dB); BLC, WDR, SSDR; H.265, H.264, MJPEG, Minimum 3Nos. individually configurable simultaneous streams in H.265 @ 2592 x 1944 & 30 Fps or better supported;Audion in and out. Micro SD/SDHC/SDXC minimum memory 1 slot (Min. 256 GB or higher in each) rate shall inclusive of 256GB SD/SDHC/SDXC. IPv4, IPv6, TCP/IP, UDP/IP, RTP(UDP), RTP(TCP), RTCP, RTSP, NTP, HTTP, HTTPS, SSL/TLS, DHCP, FTP, SMTP, ICMP, IGMP, SNMPv1/v2c/v3(MIB-2), ARP, DNS, DDNS, QoS, UPnP, Bonjour, LLDP, CDP, SRTP, (TCP, UDP Unicast), IP66, IK10. Other technical detail shall be satisfied / complied as per the technical specifications.

82

-

-

... More
Supply, Installation, Testing and Commissioning of 2MP (1960 x 1080) * 4Lens IP Multi directional camera 4 x 1/2.8” Progressive Scan CMOS or better Multi-directional Camera, Motorized PTRZ support, Max. 30fps@5MP (H.265, H.264), 3.3 ~ 5.7 mm motorized varifocal lens, IR viewable length : 20m, H.265, H.264, MJPEG codec, supports BLC, WDR-120dB, Colour: 0.1 Lux or better B/W": 0.0 Lux (IR ON) Minimum 3Nos, individually configurable simultaneous streams in H.264,H.265 @ 2560x1920 & 25 Fps and Motion JPEG. Micro SD/SDHC/SDXC minimum memory 2 slot (Min. 512GB or higher in each) rate shall inclusive of 512GB SD/SDHC/SDXC. IPv4, IPv6, TCP/IP, UDP/IP, RTP(UDP), RTP(TCP), RTCP, RTSP, NTP, HTTP, HTTPS, SSL/TLS, DHCP, FTP, SMTP, ICMP, IGMP, SNMPv1/v2c/v3(MIB-2), ARP, DNS, DDNS, QoS, UPnP, Bonjour, LLDP, CDP, SRTP, (TCP, UDP Unicast), IP66, IK10. Other technical detail shall be satisfied / complied as per the technical specifications.

2

-

-

... More
Supply, Installation, Testing and Commissioning of 5MP IR PTZ Camera with built-in Wiper, Image Sensor:1/2.8" Progressive Scan CMOS, Min. Illumination: Color: 0.1Lux, BW: 0Lux (IR LED On), 30fps, Image Compression H.264 / H.265 / MJPEG or better, White Balance, Noise Reduction: 2D/3D DNR, Blur Detection: Yes, Shutter Speed: 2 - 1/12,000 sec or better, Day & Night: True Day/Night with ICR, Optical Zoom: 30X, Digital Zoom: 12X. Focus Mode: Auto / Manual, Focal Length: 5-150 mm IR Distance: 200 Meter or better built-in wiper, Optimized IR with adjustable intensity, and angle IR or better depending on the zoom ratio, Alarm Trigger: Alarm Input, Video Streams: Minimum 3 Nos, individually configurable streams in H.265@ 8MP resolution & 30 Fps, SD Card: Built in SD card slot with support up to 512GB or higher (inclusive of 1TB memory card), better Hi PoE supported, Working Temperature: -30°C ~ +55°C Protection Level: IP66, IK10, NEMA4X, NEMA-TS 2 (2.2.8, 2.2.9). IPv6, TCP/IP, UDP/IP, RTP(UDP), RTP(TCP), RTCP, RTSP, NTP, HTTP, HTTPS, SSL/TLS, DHCP, PPPoE, FTP, SMTP, ICMP, IGMP, SNMPv1/v2c/v3(MIB-2), ARP, DNS, DDNS, QoS, PIM-SM, UPnP, Bonjour, LLDP IP66, IK10; IP67, IK10, NEMA4X rated. The PTZ Camera shall be powered by POE also the cost shall inclusive of POE injector for required power to energies the PTZ Camera. Other technical detail shall be complied as per the technical specifications.

6

-

-

... More
Supply, Installation, Testing and Commissioning of ANPR Camera - 2MP IR Bullet Camera, 6~60mm (10x) Zoom, Color: 0.03 Lux (F1.6, 1/30 sec, 30IRE), 0 Lux (IR LED on), Max. 120 fps (H.265/H.264), Min. 3 individually confrigurable stream in H.265 at 2MP & 120fps, Maximum IR viewable length 90mtr, Day & Night (ICR), extremeWDR (150 dB), DIS with built-in Gyro sensor, Analytics events based on AI engine (NPU) : Object detection (Person/Face/Vehicle - car, truck, bus, bicycle, motorcycle/License plate), IVA (Virtual line/Area, Enter/Exit, Loitering, Direction, Intrusion), Analytics events : Defocus detection, Motion detection, Tampering, Fog detection, Audio detection, Sound classification, Shock detection, Appear/Disappear, IP67, NEMA4X, IK10, PoE, CE, FCC, BIS, UL.

8

-

-

... More
Supplying, installation, testing and commissioning of IP Based Ultrakey Lite Control keyboard with function key, joystick, LED display, Dedicated Programmable keys for Operations

1

-

-

... More
Supply, installation, testing & commissioning of Main / Primary Recording Server required for 400 cameras or Higher, VMS embedded Server, recording - Live/playback via Workstation, Max. each server support Recording bandwidth min 700Mbps for min 128 CH in each Server, Intel Xeon Processor, 4 x 16GB ECC memory, min 24 Bay 3.5” HDD, system must have N+1 Fail-Over, Auto backup from SD card,Normal, Schedule (Continuous / Event), Event (Pre / Post),, Event Action- Instant Viewer, Preset, Alarm Out, Pop-up, Sound and E-mail notification RAID 0/1/5/6, Windows 10 IoT Enterprise, CE, & BIS. a. 45 days storage retention with 2MP Resolution, 2mbps bandwidth of each camera encoding, 25 Frames per second, H.265 Compression for 400 Cameras. b. All required storage devices with minimum of 8TB Surveillance Internal Hard Drive HDD-3.5 Inch SATA 6Gb/s 256MB Cache + Drive Health Management & 3-Year Recovery Service, speed of 7200rpm or better Surveillance Hard Disk Drive in each HDD Bay shall be included. However, total Camera storage calculation shall be generated from CCTV Camera OEM Software and the same shall be considered. c. The server based analytics (ANPR & Face Recognition) licenses, Software and its Server Hardware No additional cost shall be provided separately.

1

-

-

... More
Supply, installation, testing and commissioning of Client workstation Intel core 9th Generation Intel Core i9 Processor by latest generation or better, 16GB DDR3 RAM, 64-bit operating system, 1TB SSD for OS and Security Center applications, with a minimum of 16 GB of free disk space to install the Security Center client application, 1TB SATA Hard disk with 7200rpm, GbE network interface card, DVD-RW standard keyboard & Mouse with Dual NVIDIA® GeForce® RTX 2080 video card with 21" 4K / UHD LED MONITOR LED MONITOR. Minimum 4 HDMI,1 parallel, 8 USB 2.0, 1 serial, 2 Ultra ATA/100, 2optional IEEE1394, 1 USB Keyboard, 1 USB Mouse, 1 video, 1 Microphone jack, 1 Line-in jack, 2 x 1GBPS RJ-45 Interface Port. Note: The Configuration mentioned is only Minimum requirement. Vendor shall be consider as per the CCTV Camera OEM & Video Managment System Software OEM recommendations, in case of higher configurations shall be required to enable the functional requirements and consider the cost for the same & quote accordingly. Bidder shall be considered the specified configuration if the CCTV Camera OEM & Video Managment System Software do not have an objection. No deviation shall be accepeted.

1

-

-

... More
Supply, Installation, Testing & Commissioning of Main Viewing Screens with wall mount 6 x 42" 4K UHD LED Screens, with HDMI/VGA outputs, PC inputs. Screens should have 2 ms or better response time, Energy Star compliant & capable to operate for 24x7 operation. It shall come with remote control and shall have various picture mode options for data representation with all necessary fixing accessiories for viewing. Note: The display shall be mounted 3 x 2 matrix and all four screen to be considered as single display screen / monitor. One input from Server / Client / CCTV Client PC shall be interfaced with Monitor Station. All necessary display controller, Encoder, Decoder, Splitter and Display configuration software etc., shall be considered to complete the successful installation of Video Display. Bidders shall be considered the necessary additional equipment cost in this line item. No additional cost shall be provided if will require to comply the above requirement.

1

-

-

... More
Supply, installation, testing and commissioning of 3 Metre Length Pole with Base Plate (250 x 250 x 6mm) 76.10mm OD x 3.65mm Thick x 3000mm Length Integral junction chamber flush with the pole for termination of CAT-6A and power cables. Including Bakelite sheet. Provided with a camera mounting plate - fixed to the pole with provision of holes for camera mounting - holes dimensions to be provided by you. PU coated through 5 tank cleaning process and with 2 coats of primer and 2 coats of PU paint and topcoat for extra weather protection. Poles are fine finished. The rate shall inclusive of all the necessary camera mounting accessories, back boxes, Termination Junction Boxes for power supply (if required), 4 Nos of Anchor bolt shall be 25mm dia and 500mm length, 2 Nos of 32mm GI pipe medium class collar bend for cable entry at the bottom of the foundation etc., to be considered. The Pole Cost shall be inclusive of all required RCC foundations as mentioned the foundation details of 450mm (L) x 450mm (W) x 1000mm (H) RCC M25 Grade. The Pole cost shall inclusive of excavation, shuttering, foundations and backfilling the soil etc. no extra cost shall be provided to Civil contractor.

12

-

-

... More
Supply, installation, testing and commissioning of 6 Metre Length Pole with Base Plate (250 x 250 x 6mm) 76.10mm OD x 3.65mm Thick x 6000mm Length Integral junction chamber flush with the pole for termination of CAT-6A and power cables. Including Bakelite sheet. Provided with a camera mounting plate - fixed to the pole with provision of holes for camera mounting - holes dimensions to be provided by you. PU coated through 5 tank cleaning process and with 2 coats of primer and 2 coats of PU paint and topcoat for extra weather protection. Poles are fine finished. The rate shall inclusive of all the necessary camera mounting accessories, back boxes, Termination Junction Boxes for power supply (if required), 4 Nos of Anchor bolt shall be 25mm dia and 500mm length, 2 Nos of 32mm GI pipe medium class collar bend for cable entry at the bottom of the foundation etc., to be considered. The Pole Cost shall be inclusive of all required RCC foundations as mentioned the foundation details of 450mm (L) x 450mm (W) x 1000mm (H) RCC M25 Grade. The Pole cost shall inclusive of excavation, shuttering, foundations and backfilling the soil etc. no extra cost shall be provided to Civil contractor.

6

-

-

... More
INTEGRATED BUILDING MANAGEMENT SYSTEM

-

-

-

... More
INTEGRATED BUILDING MANAGEMENT SYSTEM SERVER Supply, installation, testing and commissioning of 4th Gen Intel Xeon Scalable (1.9 GHZ / 6-CORE / 15MB / 85W) Processor, 8DIMM Slots 2Nos. of 8GB DDR4 RAM, with NVIDIA Graphics Card, 8 LFF (3.5 inch) Hot Plug SAS/SATA Open Bay 4 Nos.of HP 2TB 6G SATA 7.2K 3.5IN MDL SC HDD SAS/SAT H240 Smart HBA with encryption key external DVD R/W 1 x 800W/900W Gold HT PLG PWR Ethernet 1GB 2-Port 36I Adapter with 2GB NAND, Standard Keyboard & Mouse + Microsoft Windows Server Latest Edition, Standard with Anti-virus and MS SQL Server License, The Communication protocol shall be one of the Industry Standard Open Protocols such as BACNet, ModBus, TCP/IP, LonWorks etc. through IP Protocol (Not in MSTP protocol) System should be scalable. Note: The Configuration mentioned is only Minimum requirement. Vendor to consider as per OEM recommendations in case of higher configurations required as per System requirements to fulfil the complete functionality of the system and Bidder to consider the cost for the same & quote accordingly. No Additional Cost shall be paid for Redundancy Server. The Server shall be Balde Type and its should be Rack mounted. Tower type shall not be accepted.

1

-

-

... More
Supply, installation, testing and commissioning of 3D User Friendly Realtime Graphical User Interface (GUI) BMS Head-End Software. The system should be accessible from anywhere on LAN or WAN or Ethernet without additional licenses. The Communication protocol shall be one of the Industry Standard Open Protocols such as BACNet/IP, Modbus, LonWorks, KNX etc. Software should be scalable & no extra communication driver license required shall be acceptable. The Cost of the Software shall have a inbuilt Server licenses (Main + Cloud Server) and 5 concurrent user client licenses with upgradable to unlimited web user license. 1. The rate shall inclusive of BTU billing software capable of generating necessary report/billing format for direct billing to the tenants. Provision for Customisation of Software as per customer. Thrd party software shall be accepted for BTU Billing activities. However the same software shall be proven technology in India Market and the OEM of BTU Meter Billing Software must submit the completion certificate and healthy certificate of the Software functional from Multi-User Tenant Corporate Customer. 2. The BMS Head End Software shall have an inbuilt EV Charging Consumption Bill Generation Software Module. The same shall be accepted from 3rd party OEM. However, the rate shall inclusive all the requirement of EV Charging Consumption Bill Generation Software 3. The rate shall inclusive of all the furnished IO points as per the BMS IO Data Summary with inbuilt soft integration modules for 3rd party equipments integration. The Proposing 3D Graphical User Interface Software shall have a 4500 Hard wired interface points and 18000 3rd Party Integration soft points as per the IO Summary. 4. The software shall have a own property of End User Customer and there is no legal rights to claim from the OEM after successful installation.

1

-

-

... More
Supply, installation, testing and commissioning of A 4 size Laserjet Printer suitable for the application, with driver software.

2

-

-

... More
Supply, installation, testing and commissioning of Client Workstation Intel core 9th Generation Intel Core i9 Processor by latest generation or better, 16GB DDR3 RAM, 64-bit operating system, 1TB SSD for OS and Security Center applications, with a minimum of 16 GB of free disk space to install the Security Center Client Application, 1TB SATA Hard Disk Drive with 7200rpm, GbE Network Interface Card, DVD-RW Standard Keyboard & Mouse with Dual NVIDIA GeForce RTX 2080 Video Card with 21" 4K UHD LED Monitor. Minimum 4 HDMI,1 parallel, 8 USB 2.0, 1 serial, 2 Ultra ATA/100, 2 Optional IEEE1394, 1 USB Keyboard, 1 USB Mouse, 1 Video, 1 Microphone Jack, 1 Line-in jack, 2 x 1GBPS RJ-45 Interface Port Note: The Configuration mentioned is only Minimum requirement. Vendor to consider as per OEM recommendations in case of higher configurations shall be required as per project functional requirements and the bidder to consider the cost for the same & quote accordingly. The bidder needs to consider the same configuration if OEM will not have an objection for the mentioned specifications. No deviation shall be accepeted.

2

-

-

... More
IP DDC CONTROLLERS WITH NATIVE BACNet / IP CONFIGURABLE: Supply, installation, testing and commissioning of DDC Controllers, Standalone and Networkable 32 Bit DDC Controllers with I/O module as per enclosed IO List. The controllers shall be capable of standalone operation with real time clock and historical database. The DDC's shall be capable of peer to peer communication without help of system interface controller or PC. The DDCs shall be with suitable IP 55 enclosure for indoor mounted type and for all outdoor type controllers it shall be IP66 complete with all wiring and accessories. DDC Controller must have a inbuilt IoT enabled communication protocol to connect and configuring directly with Cloud BMS Server. Bidder shall Quote Accordingly. Gateway controllers shall not be accepted. The IO Count shall be referred from the IO Data Summary

-

-

-

... More
DDC - TYPE A - DDC ID - 01 - Underground FPS Pump Room

1

-

-

... More
DDC - TYPE B - DDC ID - 02 - Underground PHE Pump Room

1

-

-

... More
DDC - TYPE E - DDC ID - 03 - Ground Floor HT Panel / Transformer Room

1

-

-

... More
DDC - TYPE F - DDC ID - 04 - Ground Floor Chiller Plant Room

1

-

-

... More
DDC - TYPE G - DDC ID - 05 - Ground Floor HUB Room

1

-

-

... More
DDC - TYPE H - DDC ID - 06 - First Floor LT Panel Room

1

-

-

... More
DDC - TYPE I - DDC ID - 07 - First Floor LT Panel Room

1

-

-

... More
DDC - TYPE J - DDC ID - 08 - First Floor Electrical Room

1

-

-

... More
DDC - TYPE K - DDC ID - 09 - First Floor HUB Room

1

-

-

... More
DDC - TYPE L - DDC ID - 10 - Second Floor HUB Room

1

-

-

... More
DDC - TYPE M - DDC ID - 11 - Second Floor Cafeteria

1

-

-

... More
DDC - TYPE N - DDC ID - 12 - Second Floor Cafeteria

1

-

-

... More
DDC - TYPE O - DDC ID - 13 - Second Floor HUB Room

1

-

-

... More
DDC - TYPE P - DDC ID - 14 - Second Floor HUB Room

1

-

-

... More
DDC - TYPE Q - DDC ID - 15 - 3rd, 4th, 6th & 7th Floor HUB Room

4

-

-

... More
DDC - TYPE R - DDC ID - 16 - Fifth Floor HUB Room

1

-

-

... More
DDC - TYPE S - DDC ID - 17 - 8th, 9th, 10th, 11th & 12th Floor HUB Room

5

-

-

... More
DDC - TYPE T - DDC ID - 18 - 3rd Floor to 7th Floor AHU Room

19

-

-

... More
DDC - TYPE U - DDC ID - 19 - 5th Floor and 8rd Floor to 12th Floor AHU Room

21

-

-

... More
DDC - TYPE V - DDC ID - 20 - Terrace Floor IP 67 Outdoor Type Enclosures

1

-

-

... More
DDC - TYPE W - DDC ID - 21 - Terrace Floor IP 67 Outdoor Type Enclosures

1

-

-

... More
DDC - TYPE X - DDC ID - 22 - Terrace Floor IP 67 Outdoor Type Enclosures

1

-

-

... More
DDC - TYPE Y - DDC ID - 23 - Terrace Floor IP 67 Outdoor Type Enclosures

1

-

-

... More
DDC - TYPE Z - DDC ID - 24 - Terrace Floor IP 67 Outdoor Type Enclosures

1

-

-

... More
DDC - TYPE Z - DDC ID - 25 - Terrace Floor IP 67 Outdoor Type Enclosures

1

-

-

... More
DDC - TYPE Z - DDC ID - 26 - STP Plant Room

1

-

-

... More
THIRD PARTY SOFT INTEGRATION: Supply, installation, testing and commissioning of Required Gateways / Open Protocol Software for integrating the foll third party system communicating on one of the Standard Open Protocols such as BACNet, ModBus, M-Bus, J-Bus etc - Vendor to considered required No. of Integrators for soft point qty's mentioned in IO summary. Maximum qty in one loop cannot exceed 20 nos. Accordingly integrator qty to be selected. a. Electrical Multifunction Meters (Each Meter 10 Points through Modbus over RS485 protocol) b. BTU Meter Integration (Each Meter 10 Points through M-Bus / Modbus over RS485 protocol) c. DG Synchronous Panel PLC integration (200 points - Modbus over RS485 protocol / BACnet over MSTP) d. UPS (Each UPS 15 Points through Modbus over RS485 protocol) e. Secondary Pump PLC Panel (Each PLC Panel 100 points through Modbus over RS485 protocol/ BACnet over MSTP) f. EC Fan (Each Fan 10 points through Modbus over RS485 protocol. g. Fire Alarm Panels & Firefighting Pump Panel (6500 points - Modbus over RS485 protocol / BACnet over MSTP) i. CHW Cassette Unit (Each unit 10 Points through Modbus over RS485 protocol) j. Water Meter Integration (Each Meter 5 Points through Modbus over RS485 protocol / BACnet over MSTP) k. Elevator Monitoring System - (Each Elevator / Lift 10 Points through Modbus over RS485 protocol / BACnet over MSTP) l. Water Cooled Chiller Plant Manager - (200 points through Modbus over RS485 protocol / BACnet over MSTP) m. Air Cooled Chiller Plant Manager - (100 points through Modbus over RS485 protocol / BACnet over MSTP) n. PHE Pumps PLC Panel Integration - (100 points through Modbus over RS485 protocol / BACnet over MSTP) o. Solar System Panel Integration - (100 points through Modbus over RS485 protocol / BACnet over MSTP) p. EV charging point integration - (10 Points in each Charging Station through Modbus over RS485 protocol / BACnet over MSTP) q. HSD Tank Flow Monitor Integration - (50 Points through Modbus over RS485 protocol / BACnet over MSTP) r. HSD Tank Consumption Meter Integration - (50 Points through Modbus over RS485 protocol / BACnet over MSTP) s. VFD (Each VFD 10 points through Modbus over RS485 protocol) t. Transformer Integration (Each Transformer 20 points through Modbus over RS485 Protocol) u. HT Panel PLC System Integration (Each Panel 100 Points through Modbus over RS 485 / BACNet IP Potocol) v. Thermostat integrration (Each Thermostat 10 Points through Modbus over RS 485 / BACNet IP Potocol)

1

-

-

... More
Temperature Sensors - Duct Type - Indoor. Supply, installation, testing and commissioning of Temperature Sensors - Duct Type - Indoor. shall be of the Resistance Temperature detector (RTD) type or thermistor. These shall be two wire type . It shall be with rigid stem and of averaging type. These shall be suitable for duct installation. Accuracy shall be ± 2 deg C. Temperature range shall be 0 -50 deg C.

97

-

-

... More
Temperature Sensors - Immersion type - Cold Water - Indoor Supply, installation, testing and commissioning of Temperature Sensors - Immersion type - Cold Water - Indoor shall be of the Resistance Temperature detector (RTD) type or thermistor. These shall be two wire type. It shall be provided with separate Brass thermo well. These shall be manufactured from bar stock with hydrostatic pressure rating of at least 10 kgf/cm2. Accuracy shall be ± 2 deg C. Temperature range shall be 0 -50 deg C. The rate shall inclusive of Brass Thermowell. No additional cost shall be provided for Thermowell.

207

-

-

... More
Differential Pressure Transmitter - Water Type Supply, installation, testing and commissioning of Differential Pressure Transmitter to mount across the Chillers to monitor the Water Pressure in bith Inlet & outlet. These shall be manufactured from bar stock with hydrostatic pressure rating of at least 10 kgf/cm2. Accuracy shall be ± 2%.

12

-

-

... More
Temperature & RH Sensors - Wall Mount type - Outdoor (For Ambient T & RH). Supply, installation, testing and commissioning of Temperature & RH Sensors - Wall Mount type - Outdoor (For Ambient T & RH). shall be provided with a sun shield. Sensors shall be of capacitance type with an effective sensing range of 0% to 93% RH. Accuracy shall be + 2% or better. Duct mounted humidity sensors shall be provided with a sampling chamber. Sensors shall be provided with a housing. Temperature range shall be 0 -50 deg C and accuracy shall be ± 2 deg C. Temperature sensor shall be of the Resistance Temperature detector (RTD) type or thermistor

2

-

-

... More
Co2 Sensors - Wall Mount type - Outdoor (For Ambient Co2 Level Measuring). Supply, installation, testing and commissioning of Ambient type CO2 Sensor. Carbon Dioxide Transmitter should be wall mounted with 0 – 2000 PPM Range. These shall work on 24V AC/DC supply with +/- 10% variation the output being standard type i.e. 4-20 mA / 0 - 10 Volts etc with an accuracy of +/- 2%

2

-

-

... More
Temperature & RH Sensors - Wall Mount type - Indoor (For Room T & RH) with display Supply, installation, testing and commissioning of Temperature & RH Sensors - Wall Mount type - Indoor (For Room T & RH) with display shall be of capacitance type with an effective sensing range of 0% to 93% RH. Accuracy shall be + 2% or better. Duct mounted humidity sensors shall be provided with a sampling chamber. Temperature range shall be 0 -50 deg C and accuracy shall be ± 2 deg C. Temperature sensor shall be of the Resistance Temperature detector (RTD) type or thermistor

13

-

-

... More
Temperature & RH Sensors - Duct Mount type - Indoor (For Room T & RH) Supply, installation, testing and commissioning of Temperature & RH Sensors - Duct Mount type - Indoor (For Room T & RH) shall be of capacitance type with an effective sensing range of 0% to 93% RH. Accuracy shall be + 2% or better. Duct mounted humidity sensors shall be provided with a sampling chamber. Temperature range shall be 0 -50 deg C and accuracy shall be ± 2 deg C. Temperature sensor shall be of the Resistance Temperature detector (RTD) type or thermistor

91

-

-

... More
Velocity Sensors - Duct Mount type - Indoor Supply, installation, testing and commissioning of Air Velocity Sensor shall be integrated Surface / Duct mounted type on the field. These shall work on 24V AC/DC supply with +/- 10% variation the output being standard type i.e. 4-20 mA / 0- 10 Volts etc with an accuracy of +/- 3%

91

-

-

... More
Duct Static Pressure Sensor (For AHU static pressure monitoring). Supply, installation, testing and commissioning of Duct Static Pressure Sensor (For AHU static pressure monitoring). Range shall be 0-500 Pa, Accuracy at ±1% FS, It shall be IP54 rated. Vertically mounted with pressure connections pointing downwards.

97

-

-

... More
Differential Pressure Switch for Fan Status (Outdoor type) Supply, installation, testing and commissioning of Differential Pressure Switch for Fan Status (Outdoor type) shall be diaphragm operated. Switches shall be supplied with air connections permitting their use as static or differential pressure switches. The switch shall be of differential pressure type complete with connecting tube and metal bends for connections to the duct. The housing shall be IP 67 rated.

12

-

-

... More
Differential Pressure Switch for Fan Status (Indoor type) Supply, installation, testing and commissioning of Differential Pressure Switch for Fan Status (Indoor type) shall be diaphragm operated. Switches shall be supplied with air connections permitting their use as static or differential pressure switches. The switch shall be of differential pressure type complete with connecting tube and metal bends for connections to the duct

95

-

-

... More
Differential Pressure Switch - Filter Status (Outdoor type) Supply, installation, testing and commissioning of Differential Pressure Switch - Filter Status (Outdoor type) shall be diaphragm operated. Switches shall be supplied with air connections permitting their use as static or differential pressure switches. The switch shall be of differential pressure type complete with connecting tube and metal bends for connections to the unit. The housing shall be IP 67 rated.

12

-

-

... More
Differential Pressure Switch - Filter Status (Indoor type) Supply, installation, testing and commissioning of Differential Pressure Switch - Filter Status (Indoor type) shall be diaphragm operated. Switches shall be supplied with air connections permitting their use as static or differential pressure switches. The switch shall be of differential pressure type complete with connecting tube and metal bends for connections to the unit

96

-

-

... More
Water Level Switch Supply, installation, testing and commissioning of Water Level Switch shall be paddle type and suitable for the type of liquid flowing in the line. Output shall be 1NO/1NC potential free

8

-

-

... More
Hydrogen Sensor: Supply, installation, testing and commissioning of Wall Mount type - Indoor shal be flame proof type. Accuracy shall be +/- 10% FSD of H2%. Response time shall be less than 3 seconds

1

-

-

... More
CO2 Sensor - Duct Type - Indoor (in AHU Room Return Air path) Supply, installation, testing and commissioning of CO2 Sensor - Duct Type - Indoor (in AHU Room Return Air path) 24V AC/DC supply with the output being standard type i.e. 4-20 mA / 0- 10 Volts etc. Response time of the detector shall be 10 minutes. Range of the sensor shall be 0 to 2000 PPM

91

-

-

... More
Supplying, laying, termination, testing and commissioning of signal cables. 2 Core x 1.0 Sqmm, PVC insulated, tinned copper conductor cable Armoured Shielded ATC FRLS cable.

27680

-

-

... More
Supplying, laying, termination, testing and commissioning of signal cables. 4 Core x 1.0 Sqmm, PVC insulated, tinned copper conductor cable Armoured Shielded ATC FRLS cable.

9055

-

-

... More
Supplying, laying, termination, testing and commissioning of signal cables. 2 Core x 1.5 Sqmm, PVC insulated, tinned copper conductor cable Armoured Shielded ATC FRLS cable.

5370

-

-

... More
Supplying, laying, termination, testing and commissioning of signal cables. 3 Core x 1.5 Sqmm, PVC insulated, copper conductor cable Un-Armoured / Flexible FRLS cable.

1410

-

-

... More
Supplying and fixing of following sizes of Medium Class PVC conduit along with accessories in surface / recess including cutting the wall and making good the same in case recessed conduit as required 20mm PVC Conduit.

10763

-

-

... More
Supplying and fixing of following sizes of Medium Class PVC conduit along with accessories in surface / recess including cutting the wall and making good the same in case recessed conduit as required 25mm PVC Conduit.

7347

-

-

... More
Supplying and installing of perforated Hot dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5% in convenient sections, joined with connectors, suspended from the ceiling with G.I suspenders including G.I bolts & nuts, etc.as required. 300 mm width x 50 mm depth x 1.6 mm thickness

2406

-

-

... More
Supplying and installing of perforated Hot dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5% in convenient sections, joined with connectors, suspended from the ceiling with G.I suspenders including G.I bolts & nuts, etc.as required. 150 mm width x 50 mm depth x 1.6 mm thickness

391

-

-

... More
Supplying and installing of perforated Hot dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5% in convenient sections, joined with connectors, suspended from the ceiling with G.I suspenders including G.I bolts & nuts, etc.as required. 100 mm width x 50 mm depth x 1.6 mm thickness

40

-

-

... More
Supply and providing of PVC cable truf complete with all fittings and accessories 100mm (W) x 75mm (D)

940

-

-

... More
DATA NETWORKING & TELECOM SYSTEM (ICT)

-

-

-

... More
Supply, installation, testing and commissioning of Core Switch shall have minimum 48 x 1/10 SFP, 4*1/10G SFP Ports. Note: Bidder shall refer the Technical Tender Specifications for details for product compliance accordingly.

2

-

-

... More
Supply, installation, testing and commissioning of 1G SFP Transceiver Module for Uplink for Segment / Distribution POE switch

100

-

-

... More
Supply, installation, testing and commissioning of 10G SFP Transceiver Module for Uplink / Downlink for Core switch

4

-

-

... More
48 Port PoE+ Edge / Distribution Switch: Supply, installation, testing and commissioning of Edge Switch shall have minimum 48 *100/1000 RJ45 PoE+ ports and 4 x 1/10G SFP ports with redundant power supply. Minimum required PoE budget (48Port * 30W = 1440) 1440 Watts. Note: Bidder shall refer the Technical Tender Specifications for details for product compliance accordingly.

18

-

-

... More
24 Port PoE+ Edge / Distribution Switch: Supply, installation, testing and commissioning of Edge Switch shall have minimum 24 *100/1000 RJ45 PoE+ ports and 4 x 1/10G SFP ports with redundant power supply. Minimum required PoE budget (24Port * 30W = 720) 720 Watts. Note: Bidder shall refer the Technical Tender Specifications for details for product compliance accordingly.

5

-

-

... More
8 Port PoE+ Edge / Distribution Switch: Supply, installation, testing and commissioning of Edge Switch shall have minimum 8 *100/1000 RJ45 PoE+ ports and 4 x 1/10G SFP ports with redundant power supply. Minimum required PoE budget (8Port * 30W = 240) 240 Watts. Note: Bidder shall refer the Technical Tender Specifications for details for product compliance accordingly. The rate shall inclusive of necessary 16A Power Socket, Switch, LIU, Patch Panel, IP65 Rating weather proof Enclosure Box with DIN rail Mount arrangement to mount the Network Switch, LIU, Patch Panel etc.

6

-

-

... More
Wi-Fi Manager / Controller: Supply, installation, testing and commissioning of Centralized management Wi-Fi Manager / Controller Note: Bidder shall refer the Technical Tender Specifications for details for product compliance accordingly.

1

-

-

... More
Wi-Fi Access Points: Supply, installation, testing and commissioning of Wi-Fi Access Points Note: Bidder shall refer the Technical Tender Specifications for details for product compliance accordingly.

16

-

-

... More
Supply, installation, Testing and Commissioning of Firewall and the key features are highlighted below and the detail technical requirement shall be refered in Tender Technical Specifications and the same shall be complied with no deviation. a. Major supported features: b. Anti-Virus c. Intrusion Prevention System (IPS) d. Web filtering e. E-mail filtering, including protection against spam and grayware f. Data Leak Prevention (DLP) g. Application Control h. Traffic inspection i. Content inspection and filtering j. Security Profiles components k. Security Profiles/lists/sensors l. Logging and reporting

1

-

-

... More
Supply, installation, Testing and Commissioning of Enterprises Network Management System (EMS) and the same shall be subcription shall be considered for 36 months from the handing over the project. The Key Features are highlighted below and the detail technical requirement shall be refered in Tender Technical Specifications and the same shall be complied with no deviation. To ensure that ICT systems are delivered at the performance level envisaged, it is important that an effective monitoring and management system be put in place. It is thus proposed that a proven Enterprise Management System (EMS) is proposed by the bidder for efficient management of the system, reporting, SLA monitoring and resolution of issues. Various key components of the EMS to be implemented as part of this engagement are a. Network Monitoring System b. Server Monitoring System c. Helpdesk System d. The solution should provide a unified web-based console which allows role-based access to the users.

1

-

-

... More
Supply, installation, Testing and Commissioning of Network Managment System Server with the following configuration for Enterprises Network Management System for Building Operations: Netowrk Management Server machine: Includes Server, Windows Server Standard, SQL Server Standard. Intel Xeon Silver 3104 Processor, 8 MB L3 Cache, 6 Cores, 6 Threads 3 x 8GB RDIMM, 2666MT/s 1 x 1TB 10K RPM SAS 2.5in Hot-plug Hard Drive 2GB Network Card Windows Server 2016/2019 Standard , 104, 12 function key DD, 21" LCD Monitor, Wireless Mouse, USB Keyboard, CD/DVD Combo Writer, TCP/IP Connection. Note: The Configuration mentioned is only Minimum requirement. Vendor to consider as per OEM recommendations in case of higher configurations shall be required as per project functional requirements and the bidder to consider the cost for the same & quote accordingly. The bidder needs to consider the same configuration if OEM will not have an objection for the mentioned specifications. No deviation shall be accepeted. The Server shall be Balde Type and its should be Rack mounted. Tower type shall not be accepted

1

-

-

... More
Supply, laying, termination of both end (Field & Rack end) and Testing of Cat 6A U/FTP Cable, 4 pair, 23 AWG & UL listed and ETL tested. Bidder shall refer the Technical Tender Specifications for details for product compliance accordingly. Note: 25 Years warranty certification by OEM with Fluke test report shall be provided by the contractor to Employer. There no additional cost shall be provided for Fluke test and certifications.

32358

-

-

... More
Supply, Installation, Testing & Commissioning of 4 Pair Un-armoured 0.5mm Cable - Telephone

7528

-

-

... More
Supply, Installation, Testing & Commissioning CAT 6A Modular 24 Port Patch Panel fully loaded (Tool Less) - with Cable Manager

41

-

-

... More
Supply, Installation, Testing & Commissioning of Tool-less Cat 6A UTP Information Outlet with shutter or integrated dustcover

337

-

-

... More
Supply, Installation, Testing & Commissioning of RJ 11 Information Outlet with shutter or integrated dustcover

155

-

-

... More
Supply, Installation, Testing & Commissioning of Single / Dual Face plate for Field side, the rate shall inclusive of Flush Box - 3 Module to mount the face plate in surface, conseal, ceiling etc.

492

-

-

... More
Supply, Installation, Testing & Commissioning of Cat 6A - RJ 45 IDC plug / CCA connector UL listed and ETL tested for CCTV - Camera Side

446

-

-

... More
Supply, Installation, Testing & Commissioning of CAT 6A UTP LSZH Patch card - 1 M length

779

-

-

... More
Supply, Installation, Testing & Commissioning of CAT 6A UTP LSZH Patch card - 2 M length

283

-

-

... More
Supply, laying, termination of both end (Field & Rack end) and Testing of 12 Core OM4 Multi Mode fiber, Outdoor ECCS Armoured Unitube - LSZH outer sheath, 1500N Tensile Strength, 2000N Crush Resistance and OD 9mm. Bidder shall refer the details of technical requirement in Technical Specifications document. Note: 25 Years warranty certification by OEM with Fluke test report shall be provided by the contractor to Employer. There no additional cost shall be provided for Fluke test and certifications.

2895

-

-

... More
Supply, Installation, Testing & Commissioning of 1U Sliding Fibre panel (LIU) rack-mount 24-Fiber with splice holder, cable spool and loaded with LC Adapter and LC OM4 Pigtail at Each HUB Room

20

-

-

... More
Supply, Installation, Testing & Commissioning of LC/LC Single Mode / Multi mode Patch Cord MM OM4 bending insensitivity - 2M

84

-

-

... More
Supply and Installation of 19", 42U Rack, 800mm(W) x 800mm (D) with Front & Rear Perforated Door with lock, 1 Shelf 575 mm, castors and mounting hardware packet of 20, PDU 6 x 5/15 A(1) and 4 Nos Exhaust Fans Note: Bidder shall refer the details of technical requirement in Technical Specifications document.

9

-

-

... More
Supply and Installation of 19", 32U Rack, 800mm(W) x 800mm (D) with Front & Rear Perforated Door with lock, 1 Shelf 575 mm, castors and mounting hardware packet of 20, PDU 6 x 5/15 A(1) and 4 Nos Exhaust Fans Note: Bidder shall refer the details of technical requirement in Technical Specifications document.

7

-

-

... More
Supply and Installation of 19", 12U Rack, 600mm(W) x 600mm (D) with Front & Rear Perforated Door with lock, 1 Shelf 575 mm, castors and mounting hardware packet of 5, PDU 6 x 5/15 A(1) and 2 Nos Exhaust Fans Note: Bidder shall refer the details of technical requirement in Technical Specifications document.

5

-

-

... More
Supply and Installation of 19", Rack 9U, 600mm(W) x 600mm (D) with Front & Rear Perforated Door with lock, 1 Shelf 575 mm, castors and mounting hardware packet of 5, PDU 6 x 5/15 A(1) and 2 Nos Exhaust Fans Note: Bidder shall refer the details of technical requirement in Technical Specifications document.

3

-

-

... More
Supply, Installation, Testing & Commissioning of Server Gateway like Architecture VoIP Based IP PBX, with Industry Standard CPU based on IP at core with support for hot redundant configuration. IP PBX System Machine should be inbuilt 256 Analog and 100 IP Extensions and it can be expandable upto 896 Analog & 400 IP Extensions, 8 Trunk line + 30 SIP Trunk + 8 Digital Extension. Note: Software shall be installed in Access Control System Servers and Client licenses to be installed in Access Control System Workstation.

1

-

-

... More
Supply, Installation, Testing & Commissioning of 24 Key Digital phone - Operator phone, 480 x 272 pixels back light color display or better with LCD Display

2

-

-

... More
Supply, Installation, Testing & Commissioning of IP Phone: Display Size: 2.8 Inch, 320x240 Color Display Gigabit Ethernet Port

51

-

-

... More
Supply, Installation, Testing & Commissioning of Caller ID Telephone with Speaker

14

-

-

... More
Supply, Installation, Testing & Commissioning of 10 Pair Un-armoured 0.5mm Cable - Telephone

1615

-

-

... More
Supply, Installation, Testing & Commissioning of 20 Pair Un-armoured 0.5mm Cable - Telephone

65

-

-

... More
Supply, Installation, Testing & Commissioning of 50 Pair Un-armoured 0.5mm Cable - Telephone

65

-

-

... More
Supplying and fixing of following sizes of Medium Class PVC conduit along with accessories in surface / recess including cutting the wall and making good the same in case recessed conduit as required 25mm PVC Conduit.

21823

-

-

... More
Supplying and Laying of following Size DWC HDPE pipe ISI Marked along with all accessories like socket, bend, coupler etc., confirming to IS 14930 Part II complete with fitting, cutting and joining etc., direct in ground (750mm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required 63mm dia (OD-63mm & ID-51mm Nominal) Note: OD - Outer Diameter & ID - Inner Diameter

950

-

-

... More
Supply, Installation, Testing & Commissioning of 10 pair Floor MDF Box with krone module with Accessories to compete the work. The rate shall inclusive of All necessary jumper cables from IP-ABX Machine and interconnection tags, IP 55 Enclosures, Lock and keys etc.

5

-

-

... More
Supply, Installation, Testing & Commissioning of 20 pair Floor MDF Box with krone module with Accessories to compete the work. The rate shall inclusive of All necessary jumper cables from IP-ABX Machine and interconnection tags, IP 55 Enclosures, Lock and keys etc.

11

-

-

... More
Supply, Installation, Testing & Commissioning of 50 pair Floor MDF Box with krone module with Accessories to compete the work. The rate shall inclusive of All necessary jumper cables from IP-ABX Machine and interconnection tags, IP 55 Enclosures, Lock and keys etc.

1

-

-

... More
Supply, Installation, Testing & Commissioning of 500 (250 + 250) pair Master MDF Box with krone module with Accessories to compete the work. The rate shall inclusive of All necessary jumper cables from IP-ABX Machine and interconnection tags, IP 55 Enclosures, Lock and keys etc.

1

-

-

... More
EXTERNAL INFRASTRUCTURE WORKS

-

-

-

... More
Road Work

-

-

-

... More
Construction of Subgrade  (Construction of subgrade  with approved material having CBR 8% or more with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2)

4225

-

-

... More
Providing and applying 2.5 mm thick road marking strips (retro- reflective) of specified shade/ colour using hot thermoplastic material by fully/ semi automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoe heater, driven by experienced operator on road surface including cost of material, labour, T&P, cleaning the road surface of all dirt, seals, oil, grease and foreign material etc. complete as per direction of PMC/Employer and accordance with applicable specifications.

985

-

-

... More
Manufacturing, supplying and fixing retro reflective sign boards made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity encapsulated type heat activated retro reflective sheeting conforming to type - IV of ASTM-D 4956-01 in blue and silver white or other colour combination including subject matter, message (bi-lingual), symbols and borders etc. as per IRC ; 67:2001, pasted on substrate by an adhesive backing which shall be activated by applying heat and pressure conforming to class -2 of ASTM-D-4956-01 and fixing the same with suitable sized aluminium alloy rivets @ 20 cm c/c to back support frame of M.S. angle iron of size 25x25x3 mm along with theft resistant measures, mounted and fixed with 2 Nos. M.S. angles of size 35x35x5 mm to a vertical post made up to M.S. Tee section ISMT 50x50x6 mm welded with base plate of size 100x100x5 mm at the bottom end and including making holes in pipes, angles flats, providing & fixing M.S. message plate of required size, steel work to be painted with two or more coats of synthetic enamel paint of required shade and of approved brand & manufacture over priming coat of zinc chromate yellow primer (vertical MS-Tee support to be painted in black and white colours).Backside of aluminium sheet to be painted with two or more coats of epoxy paint over and including appropriate priming coat including all leads and lifts etc. complete as per drawing , specification and direction of PMC/Employer

-

-

-

... More
Mandatory/ Regulatory sign boards of 900 mm diametre with support length of 3750 mm

20

-

-

... More
Cautionary /warning sign boards of equilateral triangular shape having each side of 900 mm with support length of 3650 mm

5

-

-

... More
Manufacturing, supplying and fixing retro reflective overhead signage boards made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity and encapsulated lens type heat activated retro reflective sheeting conforming to type - III of ASTM-D-4956-01 as approved by PMC/Employer, letters, borders etc. as per IRC : 67-2001 in silver white with blue colour back ground and with high intensity grade, pasted on substrate by pressure sensitive adhesive backing which shall be activated by applying pressure conforming to class II of ASTM-D-4956-01 and fixing the same to the plate of structural frame work by means of suitable sized aluminium alloys, rivets or bolts & nuts @ 300 mm centre to centre all along the periphery as well as in two vertical rows along with theft resistant measures, including the cost of painting with two or more coats of epoxy paint in grey colour on the back side of aluminium sheet including appropriate priming coat. The rate includes the cost of rounding off the corners, lowering down the structural frame work from the gantry, fixing and erecting the same in position all complete as per drawings, specification and direction of the PMC/Employer(Structural frame work including M.S. plate to be provided separately. Rectangular area of the sheet only shall be measured for payment).

-

-

-

... More
Overhead informatory road signage

33

-

-

... More
Providing and fixing Glow studs of size 100x20 mm made of heavy duty body shall be moulded ASA (Acrylic styrene Acryloretrite ) or HIP (High impact polystyrene) or ABS having electronically welded micro- prismatic lens with abrasion resistant coating as approved by Engineer in charge. The glow stud shall support a load of 13635 kg tested in accordance with ASTM D4280. The slope of retro- reflective surface shall be 35 (+/-5) degress to base .The reflective panels on both sides with at least 12 cm of reflective area up each side. The luminance intensity should be as per the specification and shall be tested as described in ASTM I: 809 as recommended in BS: 873 part 4 : 1973. The studs shall be fixed to the Road surface using the adhesive conforming to IS, as per procedure recommended by the manufacturer complete and as per direction of PMC/Employer

178

-

-

... More
Supplying of Solar Raised Pavement Markers made of polycarbonate molded body with circular shape, solar powered,LED self illumination in active mode, 360 degree illumination and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face in passive mode. The marker shall support a load of 20000 kg tested in accordance to ASTM D 4280. The marker should be resistant to dust and water ingress according to IP 65 standards and should withstand temperatures in the range of 0 C to 70 C. Color of lighting could be provided in red or yellow (amber) as per requirement and typical frequency of blinking is 1 Hz. There should be current losses of less than 20 microamperes at 2.4 V in sleepcharging mode to enhance the life of the marker and a full charge should provide for a minimum autonomy of 50 hours. The height, width and length of the marker shall not be less than 10 mm x 100 mm x 100 mm. Also, the surface diameter of the marker shall not be less than 100 mm respectively. The weight of the marker shall not exceed 0.5 Kilograms. Fixing will be by drilling holes on the road for the shanks to go inside, without nails and using epoxy resin based adhesive and complete as directed by the engineer.

55

-

-

... More
Supply of imported outdoor Polycarbonate Convex Mirror with 130 Degree + actual viewing angle, equipped with adjusting swivel and mounting bracket for infinite adjustment. Diameter – 100 cm outdoor

2

-

-

... More
Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per specifications and directions of PMC/Employer

989

-

-

... More
Providing and fixing Rubber Speed Breaker in yellow & black shade with load capacity of 30 ton, moisture resistant of size 500mm 350mm x 50mm & having end cap from both ends as per approved make by design architect. ( Rate to include the required hardware accessories etc )

56

-

-

... More
Supply & installation of 40 inch Concave mirror with scratch proof & dimensional accuracy with required accessories, Hardware, etc of approved make from design architect & as per manufcaturers specificaiton

2

-

-

... More
Providing and fixing yellow & black rubber Wheel stopper for parking area with size 1840mmx 150mm x 100mm of approved make by design architect . ( cost to include installation charges along with necessary hardware, accessories, etc )

30

-

-

... More
Water Supply Network

-

-

-

... More
Ductile Iron (DI) Pipe

-

-

-

... More
Providing, supplying, transporting & handling of 200mm Dia. D.I. K-9 grade pipes and fittings as per IS 8329:2000 with inside cement mortar lining as per ISO4179/IS11906 and external bitumen coating, S.B.R rubber gaskets for flexible joints and external coating as per specifications. The rate to include freight charges, octroi, transportation to site/ store, loading, unloading, hoisting, lowering, stacking, inspection charges, etc. all complete as per tech. spec.& as directed by PMC/Employer

-

-

-

... More
200mm Dia DI-K9 Pipes

180

-

-

... More
Lowering, Laying, Jointing, fixing in position, testing & commissioning of 200mm Dia DI K-9 pipes as per IS 8329 and Specifications, The rate should be inclusive of cleaning of socket and spigot ends with approved methods before insertion of rubber gaskets, jacking and fixing in perfect conditions in trenches as per IS12288. The rates should include hydraulic/leakage testing as per specifications to specified pressure in stretches of length using pumps which should be able to provide specified test pressure, pressure gauges and other necessary equipment, labour, operation charges etc., required for testing. Rate shall also include cost of retesting if necessary complete in all respect as per specification and drawing. Item includes lifting & transporting the pipes from stacked area located anywhere in the TIDEL Park premises to specific work location, Hydraulic field testing and Commissioning as per the specifications etc. all complete as per tech. spec.& as directed by PMC/Employer.

-

-

-

... More
200mm Dia DI-K9 Pipes

180

-

-

... More
HDPE Pipes

-

-

-

... More
Providing and supplying of ISI Marked HighDensity Poly Ethylene (HDPE-PE-100) pipes and specials in standard length (6 meters) suitable for water supply as per IS Specification no. 4984/1995 or its latest revision/ ammendments including all local & central taxes & duties, freight charges, loading, unloading & conveyance to the PMC/Employer stores and stacking the same in closed shade duly protecting from sunrays, rain & theft or physical damage, etc. complete. Item includes lifting & transporting the pipes from stacked area located anywhere in the TIDEL Park premises to specific work location. (Pressure Rating : PN6)"

-

-

-

... More
75mm Dia HDPE PE-100 / PN6 Pipes

700

-

-

... More
90mm Dia HDPE PE-100 / PN6 Pipes

100

-

-

... More
Lowering, laying and jointing of HDPE pipes and specials of following class and diameter (By Electro fusion welding method) including cost of conveyance from stores to site of works at all level including cost of labour, material, giving satisfactory hydraulic testing etc. comp.

-

-

-

... More
75mm Dia HDPE PE-100 / PN6 Pipes

700

-

-

... More
90mm Dia HDPE PE-100 / PN6 Pipes

100

-

-

... More
Sluice Valves

-

-

-

... More
Providing, supplying, fixing, testing and comissioning of ISI mark C.I. / D.I. Body D/F (Manually operated PD type short body) Double Flange Sluice valves (Rising Spindle type) of approved makes & conforming to IS 14846 of class PN16 pressure class including all taxes, transportation to site, octroi, inspection charges, freight charges, insurance, loading, unloading, conveyance to stores, stacking etc. all complete as per tech. spec. & as directed by Engineer In charge.

-

-

-

1

-

-

2

-

-

... More
Electromagnetic Flow Meter

-

-

-

... More
Supply, installation, testing and commissioning of Electromagnetic Flow Meter shall be a velocity sensing Electromagnetic type, microprocessor based signal converter, sealed housing, flanged tube meter for 1.0 Mpa working pressure, manufactured to highest standard available for mag-meters, equipped with minimum six digit digital totalizers, reading in different units (Kiloliters / Cubic meter) and shall be accurate within 0.5% of Measured value, shall operate within a range of 0.3 m/sec to 4 m/sec and be constructed as follows: Meter tube (Sensor) shall be fabricated from stainless steel tube and use class PN10 flat face carbon steel flanges in accordance with IS 1538. These flanges shall be welded to the flow tube. The internal and external of the meter tube shall be blasted to near white and lined with hard rubber/ Polyurethrene/ PTFE preferably by SBR or EPDM. Meter tube shall have a constant nominal inside diameter offering no obstruction to the flow. The accuracy should be inclusive of linearity, hysteresis, repeatability, temperature and pressure effects. Coil Housing shall be fabricated from stainless steel (SS304)/ Die cast Aluminium/ Carbon steel with anticorriosive paint for corrosion resistance and welded to the tube providing a completely sealed environment for all coils, electrode connections and wiring harness capable of submerged or buried operation with IP68 Protection. Signal Converter shall be pulsed DC coil excitation type with auto zeroing.

-

-

-

... More
The signal converter shall be remotely mounted away from the meter. The converter shall indicate direction of flow and provide a flow rate indication and a total of flow volume for both forward and reverse directions. The converter shall provide an isolated 4-20 mA output into minimum 500-ohm load and a frequency output of a maximum of 0-10 KHZ and a scaled pulse output. The microprocessor based ignal converter shall have a self-diagnostic test mode and a backlit display that continuously displays “Rate of Flow” and “Total Volume”. Converter shall be supplied with a programmable low flow drop out, higher flow and empty pipe zero return. The signal converter housing should be die-cast aluminum with glass window. The converter cum transmitter should be fully programmable from the front facia. The programming should be user friendly, self-prompting menu driven. Flow meter test calibration certificate from FCRI, flow test lab / NABL accredited lab to be furnished.

-

-

-

... More
200mm Dia

1

-

-

... More
Sewerage Network

-

-

-

... More
Providing, lowering, laying, aligning,fixing in position and joining at all level/ depth full round HDPE DWC ( Double wall corrugated) pipes of SN8 grade as per IS 16098 ( Part 2) amended upto date in trenches in complete including all material , labour, sectional hydritesting ( including the cost and conveyance of water to site for testing) and commissioning as per technical specifications, drawings and as per direction of Engineer.

-

-

-

... More
150 mm dia pipe

200

-

-

... More
SFRC Manhole Cover

-

-

-

... More
Supplying and fixing in position SFRC manhole covers of 40 tonnes with frames (Heavy duty) of size 60cm Dia of best approved quality as per standard specification etc., complete compying with standard specifications . Item includes all transportation, lifting, machinery, fixing in position, labour etc required to complete the job

12

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.