Tamilnadu Water Supply And Drainage Board Tender
Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.
Tamilnadu Water Supply And Drainage Board - TWAD Tender
Machinery and Tools
Electrical and Electronics
Electrical Works
Eprocure
Opening Date29 Oct 2024
Closing Date7 Nov 2024
Tender Amount₹ 99,50,000
Costs
EMD
₹ 50,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_TWAD_497577_1Bid Award Id
ViewTender No
ifb02rishivanthiyamsdrfTender Authority
Tamilnadu Water Supply And Drainage Board ViewPurchaser Address
-Website
http://tntenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supply and delivery of clear water vertical wet type submersible pumpset suitable for 150mm dia borewell conforming to IS 8034/2002 as amended thereafter and BEE 3 Star Rated capable of discharging noted LPM against head of water column due to all causes. The pump shall be with stainless steel shaft and dynamically balanced bronze or Cast SS impeller, brass screws and CI FG 200 grade pump bowl/diffuser with ISI mark. The pump shall be directly coupled to a continous rated two pole suitable wet type vertical squirrel cage induction motor as per IS9283 /1995 as amended there after, suitable for operation in AC three phase 415 V+/- 10 %, 50 HZ
-
-
-
Head works -l 600lpmx40m Head-10HP
5
59811
299055
Supply and delivery of Star-Delta starter confirming to IS 13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/ Three Phase/50HZ (+/- 5%) and 415V (+/- 10%) including 3 pole magnetic contactor with under voltage release - 3 nos., CT operated Ammeter (65 mm dia) with suppressed scale Voltmeter (65mm dia), Voltmeter selector switch, Miniature circuit breaker, Thermal Overload relay, Air Break contactors suitable for next Standard higher KW rating,Single phasing preventor, dry running preventor and On/Off Push button switches, wiring with 1 sq.mm/4 sq. mm copper pvc insulated cable, powder coated vermin proof box, including the capacitor .
-
-
-
Head works -
10HP
10
25162
251620
Supply and delivery of 1.1 KV Grade 3 core 6 Sq.mmflat type PVC insulated copper cable confirming to IS 694/1990 with ISI marking to receive supply including cost of loading, freight, transit, insurance, incidental charges, packing, unloading and handling charges (to be laid in between Panel Board to OW Pset at sump through starter) etc.., complete., and as directed by the TWAD Board Officers (63 pairs of pupmsets having capacity upto 10 HP)
-
-
-
6 Sqmm PVC insulated copper cable
20
277
5540
Labour charges for erection and commissioning of Submersible pump sets in infiltration well including fixing and jointing submersible cable with proper clamps up to the starter to required depth and also fixing of riser pipes to the required depth valves erection clamps, pressure gauges up to the exterior wall of pump room and erection of panel board consisting of TPICN switches, starters, voltmeter, Ammeter, three pilot ( indicating ) lamps, capacitor, single phasing preventor, water level guard and laying and jointing the cables and twin earthing as per IE rules etc.,complete and as directed by TWAD Board officers
-
-
-
Head works- Infiltration well & bore well
10
14693
146935.5
Supply and delivery of 1.1 KV Grade 3.5 core 400 Sq.mm armoured aluminium conductor cross linked poly ethylene insulated PVC sheathed cables confirming to IS 7098 (part I)/1988 with ISI marking to receive supply including cost of loading, freight, transit, insurance, incidental charges, packing, unloading and handling charges etc. complete and as directed by the TWAD Board Officers. (from collection sump to Infitration wells)
205
656
134480
Laying the above cable as per IE rules between the supply point to collection sump to Infitration well as per IE Rules etc. complete and as directed by the TWAD Board Officers.
205
191
39155
Jointing of the above L.T. cable 70 sq.mm and 95 sqmm 3.5 core 1.1 KV grade Armoured Aluminium conductor cable confirming to IS1554 Part I with ISI marking including jointing materials lugs,clamps,etc
2
665
1330
Supply and delivery of the following HDPE pipes - PE 100 conforming to IS 4984/2016 and as amended from time to time with ISI marking suitable for water supply main including loading freight, transit, unloading and stacking them at stock yard etc.., complete and as directed by the TWAD Board Officers.
-
-
-
90mm HDPE PN 6 Pipe
130
250
32565
Supply, delivery and erection of vertical 40 HP turbine pumpsets in collector well at Sundarasapuram Head works
-
-
-
Supply and delivery of Vertical type water lubricated statically, dynamically, hydraulically balanced turbine pump capable of discharging the following duty condition as given below due to all causes with surface discharge head conforming to IS 1710 and as amended as on date with accessories as per IS 5120/1977 (Reaffirmed 2011 ) and as amended thereafter to suit the site condition. The speed, Number of stages, sizes of column pipes and line shaft indicated is based on site condition prevailing during investigation. The pump should be supplied with non reversible ratchet pin housing safety clutch, suction strainer etc. The Pump Bowl assembly shall be with bronze impeller running at 1450 RPM. The pump includes suitable head shaft, suitable 1.5 metre long SS line shaft required No.. to suit the well depth, Rubber line shaft bearing of required No.., C.I Bearing retainer of required No.., 100litre HDPE Pre-lubricating tank with 20mm PVC Rigid pipe connection along with GM gate valves, Suitable ERW column pipe of each 1.5m long of required No.. to suit the well depth, Suction bell mouth of suitable size, M.S.clamps suitable for column pipe/line shaft -2 set and Spanner - 1 set etc complete.
-
-
-
6000 lpm x 30 m Turbine Pump (40 HP/ 23.87KW) (Extra Set of Column Pipes - 15 m)
1
1558000
1558000
Supply and delivery of Vertical Hollow / Solid Shaft Squirrel cage VFD compatible induction motor (IS 325) suitable for the above pump continuous rated SPDP - Class 'F' insulation, squirrel cage induction motor confirming to IS 325 for operation in AC, 3 Phase/50 HZ (±5%) 415 V (±10%) running with a speed of pump noted above and with in built thrust bearing assembly capable of taking up the entire load and non - reverse ratchet assembly etc., complete. The motor rating noted above is the minimum and shall be such that it should never be over loaded when the pump works at MWL condition and shall be 10% over and above the maximum HP absorbed by the pump. The motor offered should be energy efficient to have maximum efficiency at high power factor. Separate thurst bearing assembly could also be supplied to take up the down load. Vertical Hollow / Solid Shaft Motors for Turbine Pump - AC Three Phase / 415 V / Vertical Hollow / Solid Shaft TEFC & SPDP 4 Pole Squirrel Cage Induction Motor 1500 RPM etc.., complete and as directed by the TWAD Board Officers.
-
-
-
40 HP Motor
1
165269
165269
Supply and delivery of Fully Automatic Auto Transformer Starter suitable for the motor offered. Floor mounting type air/ oil cooled Auto Transformer Starter with tapings at 50%, 65%, 80%, housed in robust steel chamber with arc and main contacts confirming to IS 8544 Part IV and as amended thereafter for operation in AC three Phase 50 Hz (+/- 5%), 415V (+/- 10%) with the following components etc. under voltage release with no volt coil,over load relay with dash pot arrangements, single phasing preventor, LED ON/ OFF switches, Mounted Ammeter, Earth leakage relay, contactor assembly suitable for next standard KW rating, incoming and outgoing cable entry provisions, transformer tank including first filling of oil etc.., complete and as directed by the TWAD Board Officers.
-
-
-
ATS starter for40 HP
1
120272
120272
Supply and delivery of KVAR Bank medium voltage Automatic Power Capacitor control unit suitable for 415 volts, 3 phase, 50 Hz. AC supply with TNEB test certificate and accessories duly banked with copper bus bars of ample current carrying capacity, sheet steel terminals, cable gland unit rating plate as per site conditions, tie rod, gasket, base frame and etc. complete with adequate size cable of required length for capacitors bank to maintain 0.95PF lead current to be provided with banking arrangements and connected to the main panel board with all accessories as per CEIG requirements ( as per IS 2834 make capacitor) The rates are basic rates with inclusive of handling charges etc.., complete and as directed by the TWAD Board Officers
-
-
-
20 KVAR
5
318
1590
Panel I in Collection Sump cum Pump House
-
-
-
Labour charges for the erection of submersible pumpset in borewell/openwell including fixing and jointing submersible cable with proper clamps upto the starter to required depth and also fixing of riser pipes to the required depth valves erection clamps, pressure gauges upto the exterior wall of pump room and erection of panel board consisting of TPICN switches starter, Voltmeter, Ammeter, three pilot (indicating) lamps capacitor single phasing preventor, water level guard and laying and jointing the cables and twin earthing as per IE rules etc., complete and testing the pumpset and trail run for 10 days.
-
-
-
40 HP
1
29845
29845.07
Supply and fixing LED OUTDOOR FITTINGS (LIGHT EMITTING DIODE) 60W LED Street Light Fitting with suitable length GI pipe bulb, wall mounting brackets clamp etc. (for pump house outside)
1
3833
3833
Supply, delivery and laying of 400 sqmm 3.5core aluminium conductor cable control room to collection sump at sundarasapuram Head works
-
-
-
Supply and delivery of 1.1 KV Grade 3.5 core 400 Sq.mm armoured aluminium conductor cross linked poly ethylene insulated PVC sheathed cables confirming to IS 7098 (part I)/1988 with ISI marking to receive supply including cost of loading, freight, transit, insurance, incidental charges, packing, unloading and handling charges etc. complete and as directed by the TWAD Board Officers. (from collection sump to Infitration wells)
-
-
-
Control room to collection sump
-
-
-
Single Run 3.5 core x400 sq.mm (1Run*700=700M)
700
2980
2086000
Supply and delivery of 1.1 KV Grade 3.5 core 400 Sq.mm armoured aluminium conductor cross linked poly ethylene insulated PVC sheathed cables confirming to IS 7098 (part I)/1988 with ISI marking to receive supply including cost of loading, freight, transit, insurance, incidental charges, packing, unloading and handling charges etc. complete and as directed by the TWAD Board Officers. (from collection sump to Infitration wells)
760
2980
2264800
Laying the above cable as per IE rules between the supply point to collection sump to Infitration well as per IE Rules etc. complete and as directed by the TWAD Board Officers. (Control room to collection sump)
700
388
271600
Laying the above cable as per IE rules between the supply point to collection sump to Infitration well as per IE Rules etc. complete and as directed by the TWAD Board Officers. (Collection sump to Collector Well)
760
388
294880
Jointing of the above L.T. cables 400 sqmm 3.5 core 1.1 KV grade Armoured Aluminium conductor cable confirming to IS1554 Part I with ISI marking including jointing materials lugs,clamps,etc
4
3026
12104
Supply, delivery of DI D/F slanted seat Swing check valve. Body of ductile cast iron GGG 40 or equivalent grade and disc of ductile cast iron GGG 40 or equivalent grade with fully encapsulated EPDM rubber, where both faces can be used. Electrostatic epoxy powder/liquid coating (EP-P) inside and outside color blue RAL 5005 with minimum coating thickness of 250 microns. The EPDM rubber & Epoxy powder should be approved by W270. (EP-P) it is a resi-coat powder approved for drinking water application, applied through fusion bonding process by dipping the shot-blasted casted components heated upto 200deg. Face to face dimensions as per EN558-1, series 48 and flange connections as per EN 1092-2/IS 1538.
-
-
-
300mm DI D/F Non Return Valve
1
129525
129525
Supply and delivery of DI D/F sluice valves (soft seated) resilient seated soft sealing sluice valves with body bonnet of ductile case iron of grade GGG 40 or equivalent grade, wedge fully rubber lined with EPDM, replaceable spindle nut, without gland packing and with 3 o-ring protection on the shaft and seals of NBR and the valves should be of vaccum tight and 100%leak proof with face to face dimentions as per BS 5163-89 / ISI 14846-2000 / DIN 3202 F4. All the valves should be with electrostatic powder coating both inside and outside with pocket less straight through body passage. All the valves are to be compatiable for burried application with pressure rating PN 10/16 etc complete.
-
-
-
300mm DI Gate valves
1
76841
76841
Maintenance of the scheme for 3 months periods at Free of cost
-
-
-
Maintenance of the scheme for 3 months periods at Free of cost
-
-
-
Maintenance of the project for the specified period by necessary maintenance crew with supervisory staff and keeping necessary specials required for pumping main/Connecting main/ Pump room/pumpsets etc.readily available to ensure uninterrupted water supply to the beneficiary including all cost towards spares,consumables, chemicals, repairs and renewal excluding cost of electrical energy payable to TNEB during maintenance period which can be got reimbursed by the Employer etc.complete as directed by TWAD Board officers.
3
-
-
Add GST @ 18 % on Basic Value
1
1514546
1514546.02
Evaluation Notes How It Works ?