Tamilnadu Industrial Development Corporation Limited Tender

Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.

Tamilnadu Industrial Development Corporation Limited - TIDCO Tender

Works
Electrical Goods and Equipments
Electrical and Electronics
Eprocure
Opening Date19 Aug 2024
Closing Date25 Sep 2024
Tender Amount₹ 85,26,51,757 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
11 kV HT Panel-2 - THREE VCB Panel - Indoor Type Design, Manufacture,Assembly,Inspection and Testing before supply,Packing and delivery at Site ,erection, Installation, Testing & commissioning of 11KV HT switchgear with all accessories and suitable for installation in three phase ,three wire,11kV,50Hz, A.C.distribution network, complete with all accessories erected in the provided foundation complete as per specfication and standards as directed by Project Officer`s in charge at Site. Indoor Type , HT Panel Comprising of 1No. 11 KV, 630A 26.2kA,3sec Horizontal Draw out type VCB as incomer & 2 Nos. 11 KV, 630A 26.2kA Horizontal Draw out type VCB as Outgoings The panel suitable for outdoor mounting & terminating of 300 sq.mm. 3 core HT XLPE 11KV (E) SISMV11E3 x 3002797 as incoming and outgoing etc, complete as directed and approved by Project Officer`s in charge. Arc flash realy needs to be provided in the Breaker, Busbar & Cable chamber. Please refer Power SIngle line Diagram and Technical specifications for protections and relays. Inbuilt battery backup needs to be considered. Inbuilt battery backup needs to be considered.

1

-

-

... More
Supply & erection of M.S. gate of size 1500mm wide & 2000mm height with all accessories,earthing of gates with braided copper including necessary civil works as required as per site condition. The Gate shall be painted with 2 coats of anticorrosive primer & 2 coats of Aluminiun enamel paint. (At RMG & HT panel-1 area)

1

-

-

... More
Supply & providing of M10 Concrete in the RMG & HT panel -1 yard as per the site conditions. The Rate shall include cleaning & levelling of the yard as required at the site. (At RMG & HT panel-1 area)

26

-

-

... More
Supply & fixing of chain link fencing of height 2meter With all supports necessary clamps, fasteners, binding wires, earthing of fencing at all sides with suitable GI wires including all accessories as required as per site condition. (At RMG & HT panel-1 area)

25

-

-

... More
Charges towards digging, excavation of normal soil to a depth of 1200mm x 600mm width and refilling the same after completion of works.

100

-

-

... More
Supply & fixing of manhole chamber sizes of 1000mm x 1000mm & including necessary four side brick required.

1

-

-

... More
TRANSFORMER

-

-

-

... More
DRY TYPE DISTRIBUTION TRANSFORMER   Design, Engineering, Manufacturing, Supply and supervision , installation, testing and commissioning of 2500KVA , 11kV/433V, Cast Resin Dry Type Distribution Transformer, 3ph, 50Hz, with vacuum break On Load Tap changer on HT side & Insulation level Class F insulated, Vector Dyn11, Continuous duty, copper wound as per relevant standard with Resistive temperature detectors with enclosure should be embedded in winding, ventilation fans, RTCC panel, Marshalling box, Bidirectional rollers, HV Side Cable box & LV Side adapter box for connecting Bus duct, Painting to be RAL-7032. Transformer suitable indoor type distribution mounted inside enclouser with all standard accessories,Transformer shall be as per SLD and specifications. Enclosure for mounting Class PS Neutral CT for REF protection to be provided. The Transformer supplier shall co-ordinate with the panel vendor & suplly & install the Neutral CT . OLTC Tap settings: +10 % to -10%, 2.5% for each step. Primary Voltage: 11000V Secondary Voltage: Losses- Low losses ECBC Building 2017. Lockable Emergency Push button should be provided . The civil works like construction of plinth, foundation etc shall be carried out by civil contractor. However, the correct sizes including type of construction shall be specified and a shop drawings shall be submitted by transformer supplier for approval before execution for review & approval by Project Officer. Note : Factory testing  shall be carried out as per the technical specifications on all the transformers. Testing shall include all routine tests as per latest IS / IEC standards and special tests like Partial discharge test, heat run test, temperature  rise test etc. All routine and special tests shall be carried out on all the transformers.

2

-

-

... More
HT CABLES

-

-

-

... More
Supply, Laying, Testing & commissioning of 300 sq.mm. 3 core HT XLPE 11KV (E) SISMV11E3 x 3002797, XLPE Aluminium armoured cable laid in underground upto 1200mm deep / existing concrete trenches / cable trays/ hume pipe , including excavation of trench & minor civil works,covering of exposed portion as per Project Officer`s-in-Charge. recommendation etc. including transportation from stores to site. Unpacking, with all labour and material as per specifications.

200

-

-

... More
Supply, Installation, Testing & commissioning of outdoor cable end termination with heat shrinkable joining kit with all accessories including lugs suitable for 240-300 sq.mm. 3 core HT Cable Outdoor Terminations XLPE 11KV (E) - EPKT 3372 etc, complete as directed by Project Officer`s in charge.

5

-

-

... More
Supply, Installation, Testing & commissioning of indoor cable end termination with heat shrinkable joining kit with all accessories including lugs suitable for 240-300 sq.mm. 3 core HT Cable Indoor Terminations XLPE 11KV (E) - EPKT 3121etc, complete as directed by Project Officer`s in charge.

5

-

-

... More
Supply, Installation, Testing & commissioning of indoor cable Staright through joining kit with all accessories including lugs suitable for 300-400 sq.mm 3 core HT Cable Straight Thorugh Joints 11KV (E) Screened XLPE Cables etc, complete as directed by Project Officer`s in charge.

1

-

-

... More
LT PANEL Supply, erection, testing and commissioning of 415V, 3 phase 4 wire 50 Hz, fully compartmentalized cubical type, fabricated with CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having required capacity extensible type FP Copper alloy bus bars of high conductivity, DMC / SMC bus bars of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity as mentioned in the below & SLD, bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, Form of separation shall be form 4B with metallic separation only entire panel shall have a common copper earth bar size as per OEM requirements at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Cu. bus bars, interconnection, interlocking between feeders etc.,

-

-

-

... More
Annuntiation window requirement shall be as per SLD. with indication lamps, push buttons necessary accessories, complete with following incoming and outgoing switchgears with protection and metering etc. as per specification and schematic diagram including provision to be made for interfacing with BMS etc. complete as required with incoming & outgoing cable entry from bottom/top and bus-duct entry from top, wiring with 2.5sq. mm. PVC insulated FRLS copper conductor , cable alleys, cable gland i/c providing following switch gears All ACBs should have Ics=Icu=Icw for 1 sec All MCCBs shall be rating for Ics=Icu as per provided SLD. All MCCBs above 63A should be provided with Copper Spreader Terminals Marshalling Bay To Be Provided for BMS Operation Please consider IP42 for Indoor panel & IP 55 for out door panels if it is not specified . Approval shall be taken for each panel before fabrication. contractor to consider the termination requirement as per the cable sizes sheet provided.

-

-

-

... More
If any additional termination box is required the same shll be considered by contractor in the panel cost itself. The fault level of the component shall be same as the bus bar fault level indicated. The panel shall be designed to suit to the site condition. If any U shape/L shape panels required as per site requirement, contractor to consider all required dummy panel, adaptor boxes, bus bar extension, other accessories, etc. in the panel cost itself. All the cost required for BMS integration like cable,control modules,converters, connectors etc as per the attached scheme shall be included in panel cost itself. The scope shall include relay coordination study. ON / OFF / TRIP status for all the incomming breakers (ACB, MCCB, MCB, MPCB, RCBO) & meter parameter from all main panel (Listed Below) to be provided through modbus IP output (PLC) to connect to BMS through ethernet switch located within one of the panels in each electrical room. All cost towards cable, ethernet switch, BMS interface module, etc shall be covered in the panel cost itself.

-

-

-

... More
Only the Main LT panel shall be fully comply to IEC 61439 part 1 & 2 of type tested assembly (TTA) . All other panels shall be partially type tested (PTTA) as per IEC60439. Any details indicated in SLD and specification is also need to be consiedered for panel cost. Any details indicated in SLD and specification is also needs to be consiedered for panel cost. All VFDs shall comply with IEC 61800-3 & have THD less than 5%. which will be in scope of Drive authorized supplier of OEM as per list of approved make. Note : Refer the SLD - TCE.12824A-EL-4001-AU-40011 to TCE.12824A-EL-4001-AU-40013

-

-

-

... More
Main LT Panel (TTA Panel) with AUTOMATIC FIRE DETECTION AND SUPPRESSION SYSTEM WITH Novec 1230/ FK5-1-12 GAS & Complete

1

-

-

... More
APFC Panel -1&2 (CAPACITOR+AHF)

2

-

-

... More
Main HVAC Panel

1

-

-

... More
Fire Emergency Panel (AUTOMATIC FIRE DETECTION AND SUPPRESSION SYSTEM WITH Novec 1230/ FK5-1-12 GAS & Complete)

1

-

-

... More
Utility Panel

1

-

-

... More
EV charging Panel Type - 1 (B1 & B2)

2

-

-

... More
EV charging Panel Type - 2 (P3)

1

-

-

... More
Common Area Lighting Panel

1

-

-

... More
Common Area Power Panel

1

-

-

... More
UPS Input Panel

1

-

-

... More
Main Basement Ventilation Panel

1

-

-

... More
Elevator Panel (AUTOMATIC FIRE DETECTION AND SUPPRESSION SYSTEM WITH Novec 1230/ FK5-1-12 GAS & Complete)

1

-

-

... More
Floor panel - 1F

1

-

-

... More
Floor panel - 2F

1

-

-

... More
Floor panel - 3F

1

-

-

... More
Floor panel - 4F

1

-

-

... More
Floor panel - 5F

1

-

-

... More
Floor panel - 6F

1

-

-

... More
Floor panel - 7F

1

-

-

... More
Floor panel - 8F

1

-

-

... More
Floor panel - 9F

1

-

-

... More
Typical Lift Control DB Panel

8

-

-

... More
LT Kiosk - 1 & 2

2

-

-

... More
UPS Output panel

1

-

-

... More
HVAC Pump panel

1

-

-

... More
Terrace HVAC panel

1

-

-

... More
Pressurization panel

1

-

-

... More
PHE panel

1

-

-

... More
Office Area Panel - 1F

1

-

-

... More
Food Court panel - 6F

1

-

-

... More
Command Control Center Panel

1

-

-

... More
Supply, Installation, testing & Commissioning of following 4P MCCB breaker with O/L, S/C & E/F protections in suitable enclosure for local isolation with Phase LED lamp, copper busbar & Breaker ON/OFF/Trip (R/Y/B/R/G). Note: For 630A rating breaker shall be provided with floor mounted type enclosure with enough space for termination of incoming & outgoing cables, necessary mounting arrangements as required.

-

-

-

... More
63A 25kA - Indoor IP42

21

-

-

... More
80A 25kA - Indoor IP42

1

-

-

... More
100A 36kA - Indoor IP42

52.5

-

-

... More
400A 36kA - Outdoor IP55

3

-

-

... More
630A 50kA - Indoor IP42

4

-

-

... More
Supply, Installation, testing & Commissioning of following Fully Automatic DOL/ Star Delta starters with features like Local/Remote, Auto/Manual & programmable timer for auto operation. Start delta starters shall be provided 5.5kW and above rating. The necessary NO NC shall be provided with BMS compatibility. The space provision for VFD with bypass facility shall be provided wherever it is specified as below. Starter will be used in case of VFD Panel Maintenance/Failure. The AHU panel to be tripped in case of fire, hence necessary contactors for the same to be provided.

-

-

-

... More
37.5 kW Star Delta Starter

1

-

-

... More
22 kW Star Delta Starter

1

-

-

... More
15 kW Star Delta Starter

1

-

-

... More
9.3 kW Star Delta Starter

1

-

-

... More
7.5 kW Star Delta Starter

1

-

-

... More
5.5 kW DOL Starter

1

-

-

... More
3.7 kW DOL Starter

1

-

-

... More
2.5 kW DOL Starter

1

-

-

... More
2.2 kW DOL Starter

1

-

-

... More
0.5 kW DOL Starter

1

-

-

... More
RISING MAIN Supply, transport to site, unloading, storing, Installation with all necessary supports, testing & commissioning of Sandwich Maintenance free Rising main with Tap off provision to be made in every 0.75 Mtr/1Mtr with Copper conductors Indoor type, dust and vermin proof. System-415V, 3Phase, 4Wire with 100% Neutral and integral 1/2 Earth, Degree of Protection: IP55(Indoor)/IP65(Outdoor). The rate shall be included of wall frame assembly, all the supports, angles etc. Note: The rate shall be included 2RX50X10mm GI. flat for Earth busbar. The maximum hot spot temperature at any point in the bus bar at the continuous rated current shall not exceed 55 deg above the maximum ambient temperature of 40 deg. Tool Kit 1 set to be included in the offer.

-

-

-

... More
BBT Straight Run with following details Conductors : Copper Rating : 2000 A,4P 50kA SC for 1 sec Configuration : 3P4W (100% N) Insulation:Class-F IP Rating : IP55 Enclosure : GI 1.6mm thickness, Impulse Withstand Voltage : 8kV Paint Shade : RAL7032 Epoxy Powder Coating

96.18

-

-

... More
End Covers

2

-

-

... More
Copper Flexibles

1

-

-

... More
Terminal flange with adopter box and extention of bus bar for terminating the bus duct.

1

-

-

... More
Accessories ( including spring hangers, fixing clips, floor seal, Etc.,)

1

-

-

... More
Supplying, installation, testing & commisioning of 2000A 50kA 4P EDO ACB with O/C, S/C, E/F release SC for 1 sec End Feed Unit for the existing Sandwich type rising mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick steel sheet enclosure (IP54) duly powder coated with Cu Busbar Arrangement Complete with Copper busbar , Indication lamps , Multi function meter for ACB with bottom Busduct entry and top Busduct outgoing provision and necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system, with all fixing accessories etc. as required .

1

-

-

... More
Supplying, installation, testing & commisioning of Tap-off boxes with 250A, 36kA 4P MCCB with Dual Source Energy Meter with RS 485 & related CTS on the existing Sandwich type rising mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick sheet steel enclosure (IP54) duly powder coated with MCCB complete etc. as required Provision to be made for BMS Integration. Separate cable alley need to be considered for cable termination considering the cable bending radius.

2

-

-

... More
Supplying, installation, testing & commisioning of Tap-off boxes with 315A, 36kA 4P MCCB with Dual Source Energy Meter with RS 485 & related CTS on the existing Sandwich type rising mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick sheet steel enclosure (IP54) duly powder coated with MCCB complete etc. as required Provision to be made for BMS Integration. Separate cable alley need to be considered for cable termination considering the cable bending radius.

1

-

-

... More
Supplying, installation, testing & commisioning of Tap-off boxes with 400A, 36kA 4P MCCB with Dual Source Energy Meter with RS 485 & related CTS on the existing Sandwich type rising mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick sheet steel enclosure (IP54) duly powder coated with MCCB complete etc. as required Provision to be made for BMS Integration. Separate cable alley need to be considered for cable termination considering the cable bending radius.

28

-

-

... More
BUSDUCTS Supply, transport to site, unloading, storing, Installation with all necessary supports, testing & commissioning of Sandwich Maintenance free busduct with Copper conductors Indoor/Outdoor type, dust and vermin proof transformer/switchgear ends & necessary locations as directed at the site from floor, ceiling, wall etc., The bus duct shall have suitable flange at ends to connect with Transformer, Main LT Panel. System-415V, 3Phase, 4Wire with 100% Neutral and integral 1/2 Earth, Degree of Protection: IP55(Indoor) & IP65 with canopy (Outdoor). The rate shall be included End box, flange connection, wall frame assembly, Phase cross chamber, horizontal & vertical connection, all required bends, end feed, adaptor boxes, flexible links with lugs for termination at the transformer end and LT panel end, supports, angles etc., Note: The rate shall be included 2RX50X10mm GI. flat for Earth busbar. The maximum hot spot temperature at any point in the bus bar at the continuous rated current shall not exceed 55deg above the maximum ambient temperature of 40 deg. Connectors between the Indoor & Outdoor Busducts need to be considered. Supply of 415V Sandwich construction Busbar trunking system with Multilayer Class-F insulation Conductors : Copper Rating : 4000 A,4P 65kA SC for 1 sec Configuration : 3P4W (100% N) IP Rating : IP55 Enclosure : GI 1.6mm thickness Impulse Withstand Voltage : 8kV Paint Shade : RAL7032 Epoxy Powder Coating

-

-

-

... More
Straight Run - IP55

288

-

-

... More
Vertical Bend 90 Degrees Bend

13

-

-

... More
Horizontal 90 Degrees Bend

23

-

-

... More
Conversion Bend/Box - From Horizontal to vertical busduct and from vertical to Horizontal busduct as per drawing with flexibles and all accessories

9

-

-

... More
Terminal flange with adopter box and extention of bus bar for terminating the bus duct.

13

-

-

... More
Accessories ( like Interconnecting bus bars rubber bellows, Flexible couplers, wall frame assembly, Etc.,)

1

-

-

... More
Phase cross over

1

-

-

... More
Supply, transport to site, unloading, storing, Installation with all necessary supports, testing & commissioning of Sandwich Maintenance free busduct with Copper conductors Indoor/Outdoor type, dust and vermin proof transformer/switchgear ends & necessary locations as directed at the site from floor, ceiling, wall etc., The bus duct shall have suitable flange at ends to connect with Transformer, Main LT Panel. System-415V, 3Phase, 4Wire with 100% Neutral and integral 1/2 Earth, Degree of Protection: IP55(Indoor) & IP65 with canopy (Outdoor). The rate shall be included End box, flange connection, wall frame assembly, Phase cross chamber, horizontal & vertical connection, all required bends, end feed, adaptor boxes, flexible links with lugs for termination at the transformer end and LT panel end, supports, angles etc., Note: The rate shall be included 2RX50X10mm GI. flat for Earth busbar. The maximum hot spot temperature at any point in the bus bar at the continuous rated current shall not exceed 55deg above the maximum ambient temperature of 40 deg. Connectors between the Indoor & Outdoor Busducts need to be considered.

-

-

-

... More
BBT Straight Run with following details Conductors : Copper Rating : 3200 A,4P 65kA SC for 1 sec Configuration : 3P4W (100% N) Insulation:Class-F IP Rating : IP55 Enclosure : GI 1.6mm thickness, Impulse Withstand Voltage : 8kV Paint Shade : RAL7032 Epoxy Powder Coating

58

-

-

... More
Vertical Bend 90 Degrees Bend

7

-

-

... More
Horizontal 90 Degrees Bend

7

-

-

... More
Conversion Bend/Box - From Horizontal to vertical busduct and from vertical to Horizontal busduct as per drawing with flexibles and all accessories

1

-

-

... More
Terminal flange with adopter box and extention of bus bar for terminating the bus duct.

7

-

-

... More
Accessories ( like Interconnecting bus bars rubber bellows, Flexible couplers, wall frame assembly, Etc.,)

1

-

-

... More
Phase cross over

1

-

-

... More
Supply, transport to site, unloading, storing, Installation with all necessary supports, testing & commissioning of Sandwich Maintenance free busduct with Copper conductors Indoor/Outdoor type, dust and vermin proof transformer/switchgear ends & necessary locations as directed at the site from floor, ceiling, wall etc., The bus duct shall have suitable flange at ends to connect with Transformer, Main LT Panel. System-415V, 3Phase, 4Wire with 100% Neutral and integral 1/2 Earth, Degree of Protection: IP55(Indoor) & IP65 with canopy (Outdoor). The rate shall be included End box, flange connection, wall frame assembly, Phase cross chamber, horizontal & vertical connection, all required bends, end feed, adaptor boxes, flexible links with lugs for termination at the transformer end and LT panel end, supports, angles etc., Note: The rate shall be included 2RX50X10mm GI. flat for Earth busbar. The maximum hot spot temperature at any point in the bus bar at the continuous rated current shall not exceed 55deg above the maximum ambient temperature of 40 deg. Connectors between the Indoor & Outdoor Busducts need to be considered.

-

-

-

... More
BBT Straight Run with following details Conductors : Copper Rating : 2000 A,4P 65kA SC for 1 sec Configuration : 3P4W (100% N) Insulation:Class-F IP Rating : IP55 Enclosure : GI 1.6mm thickness, Impulse Withstand Voltage : 8kV Paint Shade : RAL7032 Epoxy Powder Coating

120

-

-

... More
Vertical Bend 90 Degrees Bend

5

-

-

... More
Horizontal 90 Degrees Bend

13

-

-

... More
Conversion Bend/Box - From Horizontal to vertical busduct and from vertical to Horizontal busduct as per drawing with flexibles and all accessories

5

-

-

... More
Terminal flange with adopter box and extention of bus bar for terminating the bus duct.

2

-

-

... More
Accessories (like Interconnecting bus bars rubber bellows, Flexible couplers, wall frame assembly, Etc.,)

1

-

-

... More
Phase cross over

1

-

-

... More
MCB DISTRIBUTION BOARDS Supply, Installation, Testing and Commissioning of MCB Distribution board as per approved installation dwgs. Wall mounted MCB DBs with MS wire way box on top / bottom & on sides. MCBs shall be rated for 10kA with current limiting feature. Dummy ways to be covered with blank plates. All out going ways shall be labelled & laminated. Enclosure:1.2mm CRCA Sheet Steel, Powder Coated Door : Double Door Protection : IP 42 Cable Entry : Top & Bottom For UPS distribution RCCB's shall be harmonic resistant (HI/SI type) Bus bar : Shall be tinned Copper and 200% rating for UPS DB Neutral Link MCB's : 10kA 'C' Curve for Lighting & Raw power, 10kA 'D' Curve for UPS Distribution Note: 1) Separate Earth bus/Neutral bus for each phase 2) Each Circuit shall have yellow ferrules with circuit number 3) Accessories required for installation of DB's on Wall/Column/Gyp Board shall be considered 4) DB's shall be covered with powder coated (paint should match with DB Color) wire ways all around and up to ceiling to receive incoming circuits, how ever raceway shall be considered as a separate items 5) Laminated A3 OR A4 size SLD copy shall be pasted inside DB door 6) Safe shroud for Neutral link shall be provided

-

-

-

... More
Supply, Installation, Testing and Commissioning of 7 segment three phase, phase segregated, compartmentalised 12 way MCB DB Double door type, IP 42 powder coated comprising of "C" curve MCB's for LIGHTING DB. Including all fixing hardwares Incomer - 63A 4P MCB - 1 No Phase Incomer - 40A 30mA DP RCBO - 3Nos Outgoings - 10A SP MCB - 36 Nos Including all interconnections and other associated fixing accessories etc as reqd as per the site conditions.

6

-

-

... More
Supply, Installation, Testing and Commissioning of 7 segment three phase, phase segregated, compartmentalised 6 way MCBDB Double door type, IP 42 powder coated comprising of "C" curve MCB's for LIGHTING DB. Including all fixing hardwares - Type - 1 Incomer - 40A 4P MCB - 1 No Phase Incomer - 40A 30mA DP RCBO - 3Nos Timer and 2P Contactor - 3 Sets as per DB SLD Outgoings - 10A SP MCB - 18 Nos Including all interconnections and other associated fixing accessories etc as reqd as per the site conditions.

3

-

-

... More
Supply, Installation, Testing and Commissioning of 7 segment three phase, phase segregated, compartmentalised 6 way MCBDB Double door type, IP 42 powder coated comprising of "C" curve MCB's for LIGHTING DB. Including all fixing hardwares - Type - 2 Incomer - 40A 4P MCB - 1 No Phase Incomer - 40A 30mA DP RCBO - 3Nos Timer and 2P Contactor - 2 Sets as per DB SLD Outgoings - 10A SP MCB - 18 Nos Including all interconnections and other associated fixing accessories etc as reqd as per the site conditions.

4

-

-

... More
Supply, Installation, Testing and Commissioning of 7 segment three phase, phase segregated, compartmentalised 6 way MCBDB Double door type, IP 42 powder coated comprising of "C" curve MCB's for LIGHTING DB. Including all fixing hardwares - Type - 3 Incomer - 40A 4P MCB - 1 No Phase Incomer - 40A 30mA DP RCBO - 3Nos Outgoings - 10A SP MCB - 18 Nos Including all interconnections and other associated fixing accessories etc as reqd as per the site conditions.

1

-

-

... More
Supply, Installation, Testing and Commissioning of 7 segment three phase, phase segregated, compartmentalised 8 way MCBDB Double door type, IP 42 powder coated comprising of "C" curve MCB's for LIGHTING DB. Including all fixing hardwares Type - 1 Incomer - 40A 4P MCB - 1 No Phase Incomer - 40A 30mA DP RCBO - 3Nos Outgoings - 10A SP MCB - 24 Nos Including all interconnections and other associated fixing accessories etc as reqd as per the site conditions.

8

-

-

... More
Supply, Installation, Testing and Commissioning of 7 segment three phase, phase segregated, compartmentalised 8 way MCBDB Double door type, IP 42 powder coated comprising of "C" curve MCB's for LIGHTING DB. Including all fixing hardwares Type - 2 Incomer - 40A 4P MCB - 1 No Phase Incomer - 40A 30mA DP RCBO - 3Nos Timer and 2P Contactor - 2 Sets as per DB SLD Outgoings - 10A SP MCB - 24 Nos Including all interconnections and other associated fixing accessories etc as reqd as per the site conditions.

2

-

-

... More
Supply, Installation, Testing and Commissioning of Single phase, compartmentalised 12 way SPNDB Single door type, IP 42 powder coated comprising of "C" curve MCB's for LDB. Phase Incomer - 40A 30mA DP RCBO - 1Nos Outgoings - 10A SP MCB - 10 Nos Including all interconnections and other associated fixing accessories etc as reqd as per the site conditions.

4

-

-

... More
Supply, Installation, Testing and Commissioning of 7 segment three phase, phase segregated, compartmentalised 8 way MCBDB Double door type, IP 42 powder coated comprising of "C" curve MCB's for POWER DB. Incommer - 63A 4P MCB - 1 No Phase Incomer - 40A 100mA DP RCBO - 3Nos Outgoings - 16A SP MCB - 24Nos Including all interconnections and other associated fixing accessories etc as reqd as per the site conditions.

3

-

-

... More
Supply, Installation, Testing and Commissioning of 7 segment three phase, phase segregated, compartmentalised 6 way MCBDB Double door type, IP 42 powder coated comprising of "C" curve MCB's for POWER DB. Incomer - 40A 4P MCB - 1 No Phase Incomer - 40A 100mA DP RCBO - 3Nos Outgoings - 16A SP MCB - 18Nos Including all interconnections and other associated fixing accessories etc as reqd as per the site conditions.

18

-

-

... More
Supply, Installation, Testing and Commissioning of Single phase ,compartmentalised 12 way SPNDB Single door type, IP 42 powder coated comprising of "C" curve MCB's for POWER DB. Phase Incomer - 40A 30mA DP RCBO - 1Nos Outgoings - 16A SP MCB - 10 Nos Including all interconnections and other associated fixing accessories etc as reqd as per the site conditions.

2

-

-

... More
Supply, Installation, Testing and Commissioning of Single phase ,compartmentalised 12 way SPNDB Single door type, IP 42 powder coated comprising of "D" curve MCB's forr EMERGENCY LDB. Phase Incomer - 40A 30mA DP RCBO - 1Nos Outgoings - 10A SP MCB - 8 Nos Including all interconnections and other associated fixing accessories etc as reqd as per the site conditions.

18

-

-

... More
Supply, Installation, Testing and Commissioning of 7 segment three phase, phase segregated, compartmentalised 6 way MCBDB Double door type, IP 42 powder coated comprising of "D" curve MCB's for UPSDB. Incomer - 40A 4P MCB - 1 No Phase Incomer - 32A 100mA DP RCBO - 3Nos Outgoings - 16A SP MCB 'D' Curve - 12Nos Including all interconnections and other associated fixing accessories etc as reqd as per the site conditions.

15

-

-

... More
Supply, Installation, Testing and Commissioning of Single phase ,compartmentalised 12 way SPNDB Single door type, IP 42 powder coated comprising of "D" curve MCB's for UPSDB. Phase Incomer - 40A 30mA DP RCBO - 1Nos Outgoings - 16A SP MCB 'D' Curve - 8 Nos Including all interconnections and other associated fixing accessories etc as reqd as per the site conditions.

1

-

-

... More
Supply, Installation, Testing and Commissioning of Three phase, 8WAY VTPN MCCB DB Double door type, IP 42 powder coated comprising of "C" curve MCB's for CAFE/KITCHEN/SWM VTPN DB Incomer - 63A 4P MCCB - 1 No Outgoings - 40A TP MCB - 5 Nos Outgoings - 20/32A TP MCB - 3 Nos Including all interconnections and other associated fixing accessories etc as reqd as per the site conditions.

3

-

-

... More
Supply, Installation, Testing and Commissioning of Three phase, 8WAY VTPN MCCB DB Double door type, IP 42 powder coated comprising of "C" curve MCB's for KISOK VTPN DB Incomer - 63A 4P MCCB - 1 No Outgoings - 40A TP MCB - 3Nos Outgoings - 20/32A SP MCB -15Nos Including all interconnections and other associated fixing accessories etc as reqd as per the site conditions.

5

-

-

... More
Supply, Installation, Testing and Commissioning of Three phase, 12WAY VTPN MCCB DB Double door type, IP 42 powder coated comprising of "C" curve MCB's for KISOK VTPN DB Incomer - 100A 4P MCCB - 1 No Outgoings - 40A TP MCB -7Nos Outgoings - 20/32A SP MCB -15Nos Including all interconnections and other associated fixing accessories etc as reqd as per the site conditions.

1

-

-

... More
Supply, Installation, Testing and Commissioning of Three phase, 8WAY VTPN MCCB DB Double door type, IP 42 powder coated comprising of "C" curve MCB's for RAW POWER VTPN DB Incomer - 160A 4P MCCB - 1 No Outgoings - 63A TP MCB -6Nos & 32A SP MCB -6Nos Including all interconnections and other associated fixing accessories etc as reqd as per the site conditions.

1

-

-

... More
Supply, Installation, Testing and Commissioning of Three phase, 8WAY VTPN MCB DB Double door type, IP 42 powder coated comprising of "C" curve MCB's for HVAC VTPN DB Incomer - 63A 4P RCBO 100mA - 1 No Outgoings - 32A TP MCB - 4Nos. & 20A TP MCB - 4Nos. Including all interconnections and other associated fixing accessories etc as reqd as per the site conditions.

2

-

-

... More
Supply, Installation, Testing and Commissioning of Three phase, 4WAY VTPN MCB DB Double door type, IP 42 powder coated comprising of "C" curve MCB's for HVAC VTPN DB Incomer - 40A 4P RCBO 100mA - 1 No Outgoings - 32A TP MCB - 2Nos. & 20A TP MCB - 2Nos. Including all interconnections and other associated fixing accessories etc as reqd as per the site conditions.

3

-

-

... More
Supply, Installation, Testing and Commissioning of Three phase, Fabricated Outdoor type DB, TPN Vertical bus bar type, Double door , IP 55 powder coated DB comprising of "C" curve MCB's for External Lighting Incomer - 63A 4P MCCB with 63A TP Power contact, 24h timer, ON, OFF Indication lamp, Push button (Start/Stop), 1No. of Auto/Manual selector switch with TB & necessary control protection etc. - 1 No Outgoings - 32A/25A TP MCB - 8Nos. Including all interconnections and other associated fixing accessories etc as reqd as per the site conditions.

1

-

-

... More
LT CABLES & TERMINATIONS NOTES :- The Quantities (mtrs) given in the BOQ are only approximate and the contractor has to take actual measurements at site for the exact quantities of materials required before purchase of materials required for the work. Supply, laying, testing and commissioning of the following sizes of 1.1KV grade Aluminium / Copper Conductor armoured power cables Insulation of XLPE laid on trays, ceilings, walls trenches, ground etc., with necessary clamps, cable ties, fasteners, identification tags, cable marking as required. The Cost of sand, bricks and excavation should not be included in the rate quoted and measured separately. All cables shall be FRLS.

-

-

-

... More
3 1/2C X 400 sqmm A2XFY

441

-

-

... More
3 1/2C X 300 sqmm A2XFY

1025

-

-

... More
3 1/2C X 240 sqmm A2XFY

20

-

-

... More
3 1/2C X 185 sqmm A2XFY

158

-

-

... More
3 1/2C X 150 sqmm A2XFY

10

-

-

... More
3 1/2C X 120 sqmm A2XFY

184

-

-

... More
3 1/2 C X 95 sqmm A2XFY

155

-

-

... More
3 1/2 C X 70 sqmm A2XFY

389

-

-

... More
3 1/2C X 50 sqmm A2XFY

30

-

-

... More
3 1/2C X 35 sqmm A2XFY

3598

-

-

... More
4C X 25 sqmm A2XFY

2298

-

-

... More
4C X 16 sqmm A2XFY

5079

-

-

... More
3C X 50 sqmm A2XFY

10

-

-

... More
3C X 16 sqmm A2XFY

10

-

-

... More
3CX2.5sq.mm 2XWY

10

-

-

... More
3CX4sq.mm 2XWY

130

-

-

... More
3CX6sq.mm 2XWY

750

-

-

... More
3CX10sq.mm 2XWY

244

-

-

... More
3CX16sq.mm 2XWY

1722

-

-

... More
3CX25sq.mm 2XWY

79

-

-

... More
3CX35sq.mm 2XWY

252

-

-

... More
4CX6sq.mm 2XWY

4979

-

-

... More
4CX10sq.mm 2XWY

3495

-

-

... More
4CX16sq.mm 2XWY

1656

-

-

... More
4CX25sq.mm 2XWY

90

-

-

... More
3CX50sq.mm 2XY

10

-

-

... More
3CX16sq.mm 2XY

210

-

-

... More
3CX10sq.mm 2XY

10

-

-

... More
3CX4sq.mm 2XY

79

-

-

... More
1C X 10 sqmm Copper flexible cable

10

-

-

... More
1C X 16 sqmm Copper flexible cable

373

-

-

... More
1C X 25 sqmm Copper flexible cable

284

-

-

... More
4CX2.5 sq.mm 2XWY

10

-

-

... More
Fire Survival cables: Supply, loading, transportation unloading and storages at site , shifting from storage place to site of following sizes of XLPE insulated PVC sheathed,FireSurvival (FS), Aluminium/Copper conductor armoured power cable of 1.1 KV grade conforming to IS amended upto date and as per specifications.All cables shall be tagged.

-

-

-

... More
3 1/2C X 300 sqmm Al. FS cable

578

-

-

... More
3 1/2C X 240 sqmm Al. FS cable

609

-

-

... More
3 1/2C X 185 sqmmAl. FS cable

10

-

-

... More
3 1/2C X 150 sqmm Al. FS cable

273

-

-

... More
3 1/2C X 120 sqmm Al. FS cable

158

-

-

... More
3 1/2C X 50 sqmm Al. FS cable

10

-

-

... More
3 1/2C X 35 sqmm Al. FS cable

158

-

-

... More
4C X 25 sqmm Cu. FS cable

60

-

-

... More
4C X 16 sqmm Cu. FS cable

400

-

-

... More
4C X 10 sqmm Cu. FS cable

10

-

-

... More
4C X 6 sqmm Cu. FS cable

10

-

-

... More
Supply & end termination of following AL/CU armoured power cables with necessary double compression brass glands, AL/CU. terminal sockets, insulation tapes, fasteners, earthing clips & connecting the clip to main earth bus with suitable bare copper wire complete accessories as required; all outdoor double compression and indoor single compression.

-

-

-

... More
3 1/2C X 400 sqmm A2XFY

52

-

-

... More
3 1/2C X 300 sqmm A2XFY

88

-

-

... More
3 1/2C X 240 sqmm A2XFY

16

-

-

... More
3 1/2C X 185 sqmm A2XFY

10

-

-

... More
3 1/2C X 150 sqmm A2XFY

6

-

-

... More
3 1/2C X 120 sqmm A2XFY

12

-

-

... More
3 1/2 C X 95 sqmm A2XFY

6

-

-

... More
3 1/2 C X 70 sqmm A2XFY

8

-

-

... More
3 1/2C X 50 sqmm A2XFY

6

-

-

... More
3 1/2C X 35 sqmm A2XFY

144

-

-

... More
4C X 25 sqmm A2XFY

80

-

-

... More
4C X 16 sqmm A2XFY

126

-

-

... More
3C X 50 sqmm A2XFY

2

-

-

... More
3C X 16 sqmm A2XFY

2

-

-

... More
3CX2.5sq.mm 2XWY

2

-

-

... More
3CX4sq.mm 2XWY

22

-

-

... More
3CX6sq.mm 2XWY

54

-

-

... More
3CX10sq.mm 2XWY

20

-

-

... More
3CX16sq.mm 2XWY

58

-

-

... More
3CX25sq.mm 2XWY

2

-

-

... More
3CX35sq.mm 2XWY

14

-

-

... More
4CX6sq.mm 2XWY

154

-

-

... More
4CX10sq.mm 2XWY

124

-

-

... More
4CX16sq.mm 2XWY

44

-

-

... More
4CX25sq.mm 2XWY

6

-

-

... More
3CX50sq.mm 2XY

2

-

-

... More
3CX16sq.mm 2XY

22

-

-

... More
3CX10sq.mm 2XY

2

-

-

... More
3CX4sq.mm 2XY

6

-

-

... More
1C X 10 sqmm Copper flexible cable

2

-

-

... More
1C X 16 sqmm Copper flexible cable

58

-

-

... More
1C X 25 sqmm Copper flexible cable

38

-

-

... More
4CX2.5sq.mm 2XWY

2

-

-

... More
4C X 10 sqmm A2XFY

2

-

-

... More
4C X 6 sqmm 2XWY

2

-

-

... More
Fire Survival cable End Termination Supplying and making Flame Proof end termination with brass double compression Flame Proof gland and Aluminium/ copper lugs for following size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required

-

-

-

... More
3 1/2C X 300 sqmm Al. FS cable

24

-

-

... More
3 1/2C X 240 sqmm Al. FS cable

4

-

-

... More
3 1/2C X 185 sqmmAl. FS cable

2

-

-

... More
3 1/2C X 150 sqmm Al. FS cable

2

-

-

... More
3 1/2C X 120 sqmm Al. FS cable

10

-

-

... More
3 1/2C X 50 sqmm Al. FS cable

2

-

-

... More
3 1/2C X 35 sqmm Al. FS cable

6

-

-

... More
4C X 25 sqmm Cu. FS cable

6

-

-

... More
4C X 16 sqmm Cu. FS cable

20

-

-

... More
4C X 10 sqmm Cu. FS cable

2

-

-

... More
4C X 6 sqmm Cu. FS cable

2

-

-

... More
LUMINAIRES Supply & Installation, Testing and Commissioning of following Light fixtures and lamps with all accessories, fixing on the wall / ceiling/false ceiling with wooden blocks, screws, hardware's, suspended chain hooks as required as per the site conditions (including the earthing of fixture) Light fixtures complete with accessories like control gear, Drivers, Energy efficient high lumen output LED's, etc., Light Fixtures quoted rate shall include mounting bracket and lamps . Gripple/steel ropes need to be considered for suspended light fixtures Note: Lamp Colour tempature (CCT) shall be as approved by Project Officer in charge. Contractor shall consider necessary fixing hardware like supporting rods, angles etc and components to install light fixtures. The hardware viz., anchor fasteners, suspending GI chains, down rods will not be measured seperately. Contractor shall assume a minimum suspension length of 1.5 Mtrs Reference image and base rate for decorative fixtures given in the technical specifcation documet for reference.

-

-

-

... More
15W, High efficient recess mounted LED round downlighter with white powder coated, pressure die cast aluminium housing. High transmittivity PS diffuser provides soft light. CRI80, IP20, Ambient temp-0 to 45DegC, CCT - 5700K, 50,000 hrs @ L70 life. Driver efficiency85%, THD10%, Powerfactor0.9, Surge protection-2 kV, Multistage Isolated Constant Current-Constant Voltage operated driver with range 90-265V AC and Safety Extra Low Voltage Safe level60V DC as per IEC standard.IP40(Housing),IP20(Driver). Luminaire lumen ≥ 1500 lm. (100 lm/W) - Cutout Dia-ø145mm. (TYPE1 LIGHT FIXTURE)

134.2

-

-

... More
20W High efficient LED batten surface/wall mounted Specially designed extruded Aluminium housing with PC diffuser. In-built electronic driver duly wired up to terminal block.IP20, CRI 80, Temperature range-0 to 50DegC, Driver efficiency86%, Power factor0.95, CCT - 6500K, THD10%, Surge protection 2kV, 50000 burning hours as per L70 Criteria, Multistage Isolated Constant Current operated driver with range 150-270V AC and Safety Extra Low Voltage Safe level60V DC as per IEC standard. Luminaire lumen ≥ 2000 lumens (100 lm/W). (TYPE2 LIGHT FIXTURE)

588

-

-

... More
Integral, SMD LED, IP40, 40W Surface Mounted LED Batten with System efficacy of more than 110 lm/W. LED luminaire shall have sleek designwith Extruded Aluminum Section. The luminaire shall have High Optically Efficient Polycarbonate Diffuser for Uniform illumination and wider light distribution. Screwless Design ensures ease of maintenance. The LEDs used should be with CCT of 5700 K and CRI of Minimum 80. LED Driver shall be Isolated type, Constant Current topology driver with proper heat sink for heat dissipation suitable to operate in input voltage range of 150V to 270V (nominal rated voltage – 240V) with 3 KV internal surge protection, Power factor greater than 0.95 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire. (TYPE3 LIGHT FIXTURE)

550.2

-

-

... More
18W, High efficient recess mounted LED round downlighter with white powder coated, pressure die cast aluminium housing. High transmittivity PS diffuser provides soft light. CRI80, IP20, Ambient temp-0 to 45DegC, CCT - 5700K, 50,000 hrs @ L70 life.Driver efficiency85%, THD10%, Powerfactor0.9, Surge protection-2 kV, Multistage Isolated Constant Current-Constant Voltage operated driver with range 90-265V AC and Safety Extra Low Voltage Safe level60V DC as per IEC standard.IP40(Housing),IP20(Driver). Luminaire lumen ≥ 1800 lm. (100 lm/W) - Cutout Dia-ø145mm. (TYPE4 LIGHT FIXTURE)

866.25

-

-

... More
Non-integral flexible 15W LED strip light, Solid state high brightness SMD led chips, IP20 protected LED Flexible light including driver. The strip can be cut at marked intervals to suit the desired length. CRI80, Luminaire lumen ≥ 720lm.CCT-6500K. (TYPE5 LIGHT FIXTURE)

1239

-

-

... More
10W LED Bulkhead fitting with aluminium diecast housing with powder coating, Polycarbonate opal diffuser, Dome with silicon gasket for IP65 Protection, Complete assembly with LED, Driver and accessories pre wired up to terminal block. CRI80,CCT-5700K (TYPE6 LIGHT FIXTURE)

37.8

-

-

... More
80W High efficient LED with aluminium die-cast housing luminaire with unique lens system for enhanced uniform illumination and toughened glass with silicon gasket for IP66 protection.CRI70, IP66, Ambient temp-0 to 45DegC, Driver efficiency87%, THD10%, Powerfactor0.95, Surge protection-3 kV, Multistage Isolated Constant Current-Constant Voltage operated driver with range 150-270V AC and Safety Extra Low Voltage Safe level60V DC as per IEC standard. Colour Temperature - 5700k. Luminaire lumen ≥ 6800 lm.(TYPE7 LIGHT FIXTURE)

6

-

-

... More
22W 4ft,width-51mm, High efficiency long life Linear suspended luminaire with white powder coated finish extruded aluminium housing. UGR19. LED driver duly wired up to terminal block for easy installation and long service. Luminous efficacy not less than 110lm/W. CRI80, IP20, Ambient temp-0 to 45DegC, Driver efficiency85%, THD10%, CCT- 5700K, 50,000 hrs @ L70 life, Powerfactor0.95, Surge protection-2 kV, Multistage Isolated Constant Current-Constant Voltage operated driver with range 150-270V AC and Safety Extra Low Voltage Safe level60V DC as per IEC standard.Luminaire lumen ≥ 2200lm (TYPE8 LIGHT FIXTURE)

705.6

-

-

... More
Supply & Installation, Testing and Commissioning of Driveway Sensor - Mid Range LightSpot is a high-performance, directional presence detector with built-in photocell for use in almost any internal space. With a range of up to 20m by 20m

5

-

-

... More
Supply & Installation, Testing and Commissioning of Parking Area Sensor - Mid Range LightSpot is a high-performance, directional presence detector with built-in photocell for use in almost any internal space. With a range of up to 20m by 20m

54

-

-

... More
30W, 2X2 Clean Room fixture,100Lms/W, Housing made of CRCA & frame in aluminum duly powder coated in white (RAL9016), Slimmest and sleek profile with No visible hardware on external surface, High Efficiency Translucence (HET) diffuser, CCT-5700K, IP20. (TYPE9 LIGHT FIXTURE)

5.25

-

-

... More
30W IP65 rated pole mounted Aviation Light fixture in the terrace with all mounting accessories

3

-

-

... More
EXTERNAL LIGHTS Supply & Installation, Testing and Commissioning of Architectural LED Light fixture (60W-70W) (Side Mounting), Power Module LED, 4000K,IP 66, 6000lm minimum, Body in circular shape made of die-cast aluminum using pressure die casting process. manufacturer name/logo should be embosed on the body. Prismatic/Frosted screen in Flat tempered glass. Pure polyester powder coating in customised colour Metallaic Grey. Silicone gasket ensures the IP Rating - IP 66. Height – 70mm,Diameter - 420mm,Weight -8Kgs. Power LED Module with Company/brand name printed on PCB with the metal core plate, in compliance with IEC 62031 (Supporting Test Report from UL/UL Authorised/Intertek Laboratory should be submitted). CRI 70. LED Chips of CREE/NICHIA/OSRAM/LUMILEDS make shall be used- same should be supported by LED manufacturer's tech sheet . Electronic Power Supply for LED Module, which offers Protection against Short Circuit, Over- Voltage & Over- Current, with in-built surge protection (an additional surge protection device of 10kV also provided in-built the fixture). Optics with refractive lens in PMMA which should offer all the Type II,III,IV & V distribtuions. LED Lifetime 1,00,000hours@Ts 85°C. LM80 report from LED Manufacturer should be submitted. Safety test report as per IEC 60598 from UL/UL Authorised/Intertek lab should be submitted. LM79 report also should be submitted fromUL/UL Authorised/Intertek Laboratory. Sample should be submitted for approval from concerned Project Officer`s-in charge.

26

-

-

... More
Supply & Installation, Testing and Commissioning of high quality integrated LED post top Luminaire with a system lumen of 4500Lm and system wattage between 60W-70W with an efficiency 100lumen/watt. CCT of 5700K with SDCM of 5 and CRI 70. The housing should be high quality pressure die cast aluminum LM6 Alloy with PF 0.95 & Surge Protection of 4KV Internal & 10 kV External. Input voltage of 140-270V. Operating temperature should be -0 to +50 Deg C. Lifetime of 50K hours @L70. Product should be suitable for continuous operation (8 Hrs. per day). The Ingress protection should be minimum IP 65 with an IK rating of 05. The luminaire should have Integrated optics to provide a high quality glare free lighting system. The luminaire should be of Class B Serviceability, Driver Voltage range 140-270V AC and Safety Extra Low Voltage Safe level60V DC as per IEC standard, high voltage cutoff & auto restart @320V, phase to phase 440V protection upto 8hrs. The luminaire should be compliant to CISPR 15 & IES 61547 (EMC, EMI compliant). The Driver should be potted /encapsulated & should be a BIS approved driver and not a printed circuit board without casing, mounted inside the luminaire. . BIS approval for Both Driver and the luminaire needs to be submitted for records. The Light fixture body colour needs to be customised as per the Mounting pole colour.

5

-

-

... More
Supply & Installation, Testing and Commissioning of architectural pole - 6-7M Height Pole made in combination MS Pipe of 89mm dia & top single arm bracket which is made of hot dip galvanised mild steel pipe sections 60mm dian with pleasing aesthetics. The pole to be provided with a suitable size steel base plate including RCC Foundation. This mounting steel base plate along with foundation bolts of suitable size to be used for ensuring firm grouting into the specially designed RCC foundation. Entire pole & bracket shall be made to provide pleasing aesthetics as approved by Concerned Project Officer`s in-charge. After Fabrication, Entire Pole is hot dip galvanized(60 microns Minimum ) for the effective corrosion resistance . The hot dip Galvanised pole should be provided with an inbuilt junction box to fix 32A connectors and 6A MCB, at the bottom - the inbuilt box should have a flush door of suitable size. wind pressure calculation as per IS 875(part-3) & structural calculation report as per EN40 should be submitted to verify the pole strength. Pole & it's partsare painted in 3 layer coating(coating thickness-100 microns minimum) in which 1st layer with etch primer, 2nd layer with epoxy primer & 3rd final layer with PU paint- Grey colour

31

-

-

... More
Supply & Installation, Testing and Commissioning of Architectural Lighting Bollard - (10W-15W) LED - Module, 3000K, IP65 - The Lighting Bollard suitable for on ground installation is made of extruded aluminium, die cast aluminium and hot galvanized steel . It's screen made of acrylic with high impact resistance,in single piece. Pure polyester powder coating in Standard Grey Colour. IP Rating - IP 65. Height – 1000mm, Dia - 127mm LED Module on Printed Circuit Board with metal core plate.Colour Rendering Index: Ra 70.Electronic Power Supply for LED Module, which offers Protection against Short Circuit, Over- Voltage & Over- Current. Estimated LED Lifetime L80 @50,000 hours minimum. Sample should be submitted for approval from concerned Project Officer`s-in charge.

21

-

-

... More
INTERIOR LIGHTING Supply & Installation, Testing and Commissioning of following Light fixtures and lamps with all accessories, fixing on the wall / ceiling/false ceiling with wooden blocks, screws, hardware's, suspended chain hooks as required as per the site conditions (including the earthing of fixture) Light fixtures complete with accessories like control gear, Drivers, Energy efficient high lumen output LED's, etc., Light Fixtures quoted rate shall include mounting bracket and lamps . Gripple/steel ropes need to be considered for suspended light fixtures Note: Lamp Colour tempature (CCT) shall be as approved by Project officer in charge. Contractor shall consider necessary fixing hardware like supporting rods, angles etc and components to install light fixtures. The hardware viz., anchor fasteners, suspending GI chains, down rods will not be measured seperately. Contractor shall assume a minimum suspension length of 1.5 Mtrs . Reference image and base rate for decorative fixtures given in the technical specifcation documets for reference.

-

-

-

... More
18W, High efficient recess mounted LED round downlighter with white powder coated, pressure die cast aluminium housing. High transmittivity PS diffuser provides soft light. CRI80, IP20, Ambient temp-0 to 45DegC, CCT - 4000K, 50,000 hrs @ L70 life.Driver efficiency85%, THD10%, Powerfactor0.9, Surge protection-2 kV, Multistage Isolated Constant Current-Constant Voltage operated driver with range 90-265V AC and Safety Extra Low Voltage Safe level60V DC as per IEC standard.IP40(Housing),IP20(Driver). Luminaire lumen ≥ 1800 lm. (100 lm/W) - Cutout Dia-ø145mm. (TYPE10 LIGHT FIXTURE)

80.4

-

-

... More
15W, High efficient recess mounted LED round downlighter with white powder coated, pressure die cast aluminium housing. High transmittivity PS diffuser provides soft light. CRI80, IP20, Ambient temp-0 to 45DegC, CCT - 4000K, 50,000 hrs @ L70 life. Driver efficiency85%, THD10%, Powerfactor0.9, Surge protection-2 kV, Multistage Isolated Constant Current-Constant Voltage operated driver with range 90-265V AC and Safety Extra Low Voltage Safe level60V DC as per IEC standard.IP40(Housing),IP20(Driver). Luminaire lumen ≥ 1500 lm. (100 lm/W) - Cutout Dia-ø145mm. (TYPE11 LIGHT FIXTURE)

5

-

-

... More
15W, High efficient recess mounted LED round downlighter with white powder coated, pressure die cast aluminium housing. High transmittivity PS diffuser provides soft light. CRI80, IP20, Ambient temp-0 to 45DegC, CCT - 4000K, 50,000 hrs @ L70 life. Driver efficiency85%, THD10%, Powerfactor0.9, Surge protection-2 kV, Dali Dimmable driver with range 90-265V AC and Safety Extra Low Voltage Safe level60V DC as per IEC standard.IP40(Housing),IP20(Driver). Luminaire lumen ≥ 1500 lm. (100 lm/W) - Cutout Dia-ø145mm. (TYPE12 LIGHT FIXTURE)

5

-

-

... More
20W 4ft,width-51mm, High efficiency long life Linear suspended luminaire with white powder coated finish extruded aluminium housing. UGR19. LED driver duly wired up to terminal block for easy installation and long service. Luminous efficacy not less than 110lm/W. CRI80, IP20, Ambient temp-0 to 45DegC, Driver efficiency85%, THD10%, CCT- 5700K, 50,000 hrs @ L70 life, Powerfactor0.95, Surge protection-2 kV, Multistage Isolated Constant Current-Constant Voltage operated driver with range 150-270V AC and Safety Extra Low Voltage Safe level60V DC as per IEC standard.Luminaire lumen ≥ 2200lm. (TYPE13 LIGHT FIXTURE)

49

-

-

... More
20W 4ft,width-51mm, High efficiency long life Linear suspended luminaire with white powder coated finish extruded aluminium housing. UGR19. LED driver duly wired up to terminal block for easy installation and long service. Luminous efficacy not less than 110lm/W. CRI80, IP20, Ambient temp-0 to 45DegC, Driver efficiency85%, THD10%, CCT- 5700K, 50,000 hrs @ L70 life, Powerfactor0.95, Surge protection-2 kV, Dali type 2 driver.Luminaire lumen ≥ 2200lm. (TYPE14 LIGHT FIXTURE)

5

-

-

... More
40W 8ft,width-51mm, High efficiency long life Linear suspended luminaire with white powder coated finish extruded aluminium housing. UGR19. LED driver duly wired up to terminal block for easy installation and long service. Luminous efficacy not less than 110lm/W. CRI80, IP20, Ambient temp-0 to 45DegC, Driver efficiency85%, THD10%, CCT- 5700K, 50,000 hrs @ L70 life, Powerfactor0.95, Surge protection-2 kV, Multistage Isolated Constant Current-Constant Voltage operated driver with range 150-270V AC and Safety Extra Low Voltage Safe level60V DC as per IEC standard.Luminaire lumen ≥ 4400lm.(TYPE15 LIGHT FIXTURE)

5

-

-

... More
40W 8ft,width-51mm, High efficiency long life Linear suspended luminaire with white powder coated finish extruded aluminium housing. UGR19. LED driver duly wired up to terminal block for easy installation and long service. Luminous efficacy not less than 110lm/W. CRI80, IP20, Ambient temp-0 to 45DegC, Driver efficiency85%, THD10%, CCT- 5700K, 50,000 hrs @ L70 life, Powerfactor0.95, Surge protection-2 kV, Dali type 2 driver.Luminaire lumen ≥ 4400lm. (TYPE16 LIGHT FIXTURE)

5

-

-

... More
20W, 80mm diameter, 175mm hieght, LED pendent mounted Cylindrical Down Light with 80lm/W ±10% system efficacy. Luminaire shall be made up of Die Cast powder coated housing. Luminaire shall have Optical Grade shall be provided with clear glass lens with high efficiency & minimum glare to maintain 60 deg beam angle (24 deg beams are also available on request). LM 80-08 compliant, ANSI rated LEDs from reputed makes such as Nichia, Japan / Cree, USA / Bridge lux, USA / Lumiled USA / Citizen Japan should be provided. LEDs must be driven at 70% of maximum rated current for higher reliability in all our products. The LED shall be compliant with LM80-08 standard with Useful L70 life of 50000 Hrs. (Complete LM 80 test report for LED should be submitted). The LEDs used in luminaire should from Mac Adams Step 5 for CCT binning with CCT of 5700K and CRI of Minimum 80. (TYPE17 LIGHT FIXTURE)

120

-

-

... More
30W, 2X2 fixture,100Lms/W, UGR19, Housing made of CRCA & frame in aluminum duly powder coated in white (RAL9016), Slimmest and sleek profile with No visible hardware on external surface, High Efficiency Translucence (HET) diffuser,CCT-5700K, IP20. (TYPE18 LIGHT FIXTURE)

67

-

-

... More
30W, 2X2 fixture,100Lms/W, UGR19, Housing made of CRCA & frame in aluminum duly powder coated in white (RAL9016), Slimmest and sleek profile with No visible hardware on external surface, High Efficiency Translucence (HET) diffuser,CCT-5700K, IP20, Dali Dimmable driver. (TYPE19 LIGHT FIXTURE)

13

-

-

... More
20W 4ft,width-51mm, High efficiency long life Linear Recess mounted luminaire with white powder coated finish extruded aluminium housing. UGR19. LED driver duly wired up to terminal block for easy installation and long service. Luminous efficacy not less than 110lm/W. CRI80, IP20, Ambient temp-0 to 45DegC, Driver efficiency85%, THD10%, CCT- 5700K, 50,000 hrs @ L70 life, Powerfactor0.95, Surge protection-2 kV, Multistage Isolated Constant Current-Constant Voltage operated driver with range 150-270V AC and Safety Extra Low Voltage Safe level60V DC as per IEC standard.Luminaire lumen ≥ 2200lm. (TYPE20 LIGHT FIXTURE)

35

-

-

... More
40W 8ft,width-51mm, High efficiency long life Linear Recess mounted luminaire with white powder coated finish extruded aluminium housing. UGR19. LED driver duly wired up to terminal block for easy installation and long service. Luminous efficacy not less than 110lm/W. CRI80, IP20, Ambient temp-0 to 45DegC, Driver efficiency85%, THD10%, CCT- 5700K, 50,000 hrs @ L70 life, Powerfactor0.95, Surge protection-2 kV, Multistage Isolated Constant Current-Constant Voltage operated driver with range 150-270V AC and Safety Extra Low Voltage Safe level60V DC as per IEC standard.Luminaire lumen ≥ 4400lm. (TYPE21 LIGHT FIXTURE)

44

-

-

... More
Digital PIR LightSpot HD Switching PIR SensorsCeiling Mount 360 degree. Micro Detection - High Sensitivity Range 10 m Dia at height of 2.5 meter ( 7 m dia Micro Sensitivity 3 m macro) and . Current Capacity 10A. Digital Remote IR based Commissioning with hand held programmer for following Programmable features: OFF delay time 10 Sec - 96 hrs, photocell and power up (status of luminaires when power is applied). It shall have provision to manually override luminary ON/OFF status using hand held remote control.

5

-

-

... More
Digital PIR Regulating presence detection sensor of range Micro Detection - High Sensitivity Range 10 m Dia at height of 2.5 meter ( 7 m dia Micro Sensitivity 3 m macro) to control 10A lighting load. Capable of dimming 15 dimmable DSI/ DALI ballast. To be commissioned by hand held programmer with programmable features of delay time 10sec-96 hrs, photocell and power up (status of luminaires when power is applied). It shall have provision to manually override the luminaires’ ON / OFF / regulate lighting level status using hand held remote control and wired input for One switch control (push switch) to ON / OFF / regulate the lighting level.

1

-

-

... More
DECORATIVE LIGHT FIXTURE TYPE -1 Pendant /Suspended Circular luminaire with system power 9- 15W LED , luminous flux of luminaire 1400 lm, Indirect light emission CRI 80, colour temperature of 4000 K, Neutral white, 230 V constant current driver, 70% of luminous flux after 50,000 operating hours, energy-efficient LEDs, luminaire profile in aluminium, Polyester powder Black colored coat applied over a 5- stage pre-treatment, indirect Opal diffuser , ZHLS (Zero Halogen Low Smoke) internal wiring, DALI control gear, Protection class I, IP 20, Ø = 300 mm, H = 150 mm. (TYPE22 LIGHT FIXTURE)

15

-

-

... More
DECORATIVE LIGHT FIXTURE TYPE -2 Decorative pendant luminaire with HPE (High Performance Efficiency) LED luminaire lumens not less than 26 W, luminous flux of luminaire 2730 lm with system efficacy of 105 lm/W, Colour temperature of 6500 K, Cool white, CRI 80, 230V constant current driver, 70% of luminous flux after 50,000 operating hours; Energy efficient LEDs, MacAdam 3, Direct light emission, Luminaire housing in aluminium, Polyester powder black or white coloured coat applied over a 5- stage pre-treatment, Opal diffuser for a homogenous light distribution ZHLS (Zero Halogen Low Smoke) internal wiring, Electronic control gear, Protection class I, IP 20, The luminaire Dimesion shall be not less than Ø = 427 mm, H = 227 mm. (TYPE23 LIGHT FIXTURE)

85

-

-

... More
DECORATIVE LIGHT FIXTURE TYPE -3 Ceiling Mounted Circuar Decorative light with HPE (High-Performance Efficiency) LED (Light Emitting Diode) system power: 35 W luminous flux of luminaire 3500 lm, Colour temperature of 5700K, cool white CRI 80, 230V constant current driver, 70% of luminous flux after 50,000 operating hours; Energy efficient LEDs, Direct light emission, luminaire housing in aluminium, Polyester powder white coloured coat applied over a 5- stage pre-treatment, pre-wired backplate luminaire, Prismatic diffuser for homogenous light distribution, ZHLS (ZERO HALOGEN LOW SMOKE) internal wiring, DALI control gear, Protection class I, IP20, Ø = 530 mm, H = 110 mm. (TYPE24 LIGHT FIXTURE)

12

-

-

... More
DECORATIVE CHANDELIER LIGHT FIXTURE TYPE -4 Square Gold plate and Crystal Flush Mount Ceiling Chandelier. Light source - LED Material: Prefabricated , stainless steel base, Clear crystal pendant Voltage: 220V Installation Type: Flush Mount Switch Type: On/Off Size: 450mm(L) x 450mm(W) Note: This light fiiting sample shall be got prior approval from Project officer incharge before fabrication. (TYPE25 LIGHT FIXTURE)

3.15

-

-

... More
DECORATIVE CHANDELIER LIGHT FIXTURE TYPE -5 Square Gold plate and Crystal Flush Mount Ceiling Chandelier. Light source - LED Material: Prefabricated , stainless steel base, Clear crystal pendantt Voltage: 220V Installation Type: Flush Mount Switch Type: On/Off Size: 500mm(L) x 800mm(W) Note: This light fiiting sample shall be got prior approval from Project officer incharge before fabrication. (TYPE26 LIGHT FIXTURE)

3.15

-

-

... More
DECORATIVE CHANDELIER LIGHT FIXTURE TYPE - 6 Square Gold plate and Crystal Flush Mount Ceiling Chandelier. Light source - LED Material: Prefabricated , stainless steel base, Clear crystal pendantnt Voltage: 220V Installation Type: Flush Mount Switch Type: On/Off Size: 600mm(L) x 600mm(W) Note: This light fiiting sample shall be got prior approval from Project officer incharge before fabrication. (TYPE27 LIGHT FIXTURE)

6.3

-

-

... More
DECORATIVE CHANDELIER LIGHT FIXTURE TYPE - 7 Square Gold plate and Crystal Flush Mount Ceiling Chandelier. Light source - LED Material: Prefabricated , stainless steel base, Clear crystal pendant Voltage: 220V Installation Type: Flush Mount Switch Type: On/Off Size: 1300mm(L) x 900mm(W) Note: This light fiiting sample shall be got prior approval from Project officer incharge before fabrication.. (TYPE28 LIGHT FIXTURE)

2.1

-

-

... More
DECORATIVE HEXAGONAL SUSPENDED LIGHT FIXTURE TYPE - 8 Suspended continous mounted LED luminaire with wattage of 22W in Hexageon Shape as per false ceiling arrangements . The luminaire shall deliver lumen not less than 2420 lm with system efficacy of 110 lm/W. The Single luminaire dimension shall be not less than 50x85x1120mm (approx). Luminaire Consists of Grey powder coated finish pressure diecast aluminium housing & Special translucent satin finish colour LED PMMA diffuser for only downward distribution. LED make: that satisfies IEC62471 Photobiological/RoHS Standards with and LED Efficacy of 150lm/W, Colour Temperature-6500K or Higher with LED binning as per ANSI Bin C78.377A, 120Deg LED Beam Angle, CRI 80, Life of LED as per L70 50000burning hours, Ambient temp-0 to 50DegC, Driver efficiency85%, THD10%, Power factor0.95, Inbuilt Surge protection in CM ≥ 3.0KV, LED Driver with Voltage range 150-270V AC and Safety Extra Low Voltage Safe level60V DC as per IEC standard, Electrical Safety with Class 1 Insulation (TYPE29 LIGHT FIXTURE)

2

-

-

... More
WIRING FOR LUMINAIRES CIRCUIT MAIN (FROM DB TO FIRST POINT) Supply, Laying, Testing and Commissioning of Wiring for Circuit/submains along with earth wire with 2R 2.5Sq.mm + 1R 2.5S.mm FRLS PVC insulated multistrand copper wire in surface /recessed Steel conduit with all accessories as required as per site conditions. For concealed conduiting, wall chasing and finishing need to be considered in the quote. (From DB to Fist point .Switch Box and Switch Box to Switch Box )

25135

-

-

... More
Supply, Laying, Testing and Commissioning of Wiring for Circuit/submains along with earth wire with 2R 2.5Sq.mm + 1R 2.5S.mm FRLS PVC insulated multistrand copper wire in surface /recessed medium class PVC conduit with all accessories as required as per site conditions. For concealed conduiting, wall chasing and finishing need to be considered in the quote. (From DB to Fist point .Switch Box and Switch Box to Switch Box )

3565

-

-

... More
POINT WIRING - SWITCH CONTROL Supply, installation, Testing and Commissioning of switch control point wiring as describe in below line items . Conduit colour to be black in all closed ceiling and white in all open ceiling or as directed by Project officer incharge For concealed conduiting, wall chasing and finishing need to be considered in the quote.. The rate shall include providing mounting boxes with tapped holes for lights switches, moulded front plates with brass screws earthing of all points using third wire Point wiring for lights to be with connectors & flexible drops to be with proper sockets Any conduits crossing partitions/walls should have appropriate sleeves with fire sealant (fire sealant shall be covered under relavant item)

-

-

-

... More
PRIMARY LIGHT POINT Supply, installation, Testing and Commissioning of point wiring using 2Rx2.5Sq.mm + 1Rx1.5Sq.mm FRLS 1100V wire of approved with Suitable dia Steel conduit including all accessories such as bends, junction boxes etc., complete. The wiring shall be complete with ceiling roses. The rate shall include providing mounting boxes with tapped holes for lights switches, moulded front plates with brass screws earthing of all points using third wire I. Primary light point means wiring from first switch control to the first light outlet. The switch and all necessary accessories would be part of primary point. II. Not to include the incoming lighting circuit from MCB-DB to switch. III. 3 core PVC transparent clear electrical cable flex wire/cable shall be included at the drop of light fixture, flexibles with connectors and adaptors IV. Consider Average Length for each point as - 10 Mtrs.

561

-

-

... More
SECONDARY POINTS I. Secondary light point means extension of light outlet from existing primary point with suitable dia Steel conduit with 3RX1.5 Sqmm FRLS 1100V wire. Same to be controlled by the existing switch of primary point. II. 3 core PVC transparent clear electrical cable flex wire/cable shall be included at the drop of light fixture. III. Consider Average Length foreach point as- 6 Mtrs.

875.6

-

-

... More
POINT WIRING - SENSOR CONTROL Supply, installation, Testing and Commissioning of sensor with switch control point wiring as describe in below line items . Point wiring for lights to be with connectors & flexible drops to be with proper sockets Any conduits crossing partitions/walls should have appropriate sleeves with fire sealant (fire sealant shall be in civll vendor scope) The rate shall include providing mounting boxes with tapped holes for lights switches, moulded front plates with brass screws earthing of all points using third wire Conduit colour to be black in all closed ceiling and white in all open ceiling For concealed conduiting, wall chasing and finishing need to be considered in the quote.

-

-

-

... More
PRIMARY LIGHT POINT Supply, installation, Testing and Commissioning of point wiring using 2Rx2.5Sq.mm + 1Rx1.5Sq.mm FRLS 1100V wire of approved with Suitable dia Steel conduit including all accessories such as bends, junction boxes etc., complete. The wiring shall be complete with ceiling roses. The rate shall include providing mounting boxes with tapped holes for lights switches, moulded front plates with brass screws earthing of all points using third wire I. Primary light point means wiring from first switch control to the sensor, the first light outlet and to the subsequent next Switch/sensor in that circuit. The switch and all necessary accessories would be part of primary point. II. Not to include the incoming lighting circuit from MCB-DB to switch. III. 3 core PVC transparent clear electrical cable flex wire/cable shall be included at the drop of light fixture, flexibles with connectors and adaptors. IV. Consider Average Length - 10 Mtrs.

58

-

-

... More
SECONDARY LIGHT POINT Supply, installation, Testing and Commissioning of I. Secondary light point means extension of light outlet from existing primary point with Suitable dia Steel conduit with 3RX1.5 Sqmm FRLS 1100V wire. Same to be controlled by the existing switch/Sensor of primary point. II. 3 core PVC transparent clear electrical cable flex wire/cable shall be included at the drop of light fixture. III. Consider Average Length - 5Mtrs.

50

-

-

... More
POINT WIRING - SENSOR + SWITCH CONTROL Supply, installation, Testing and Commissioning of point wiring using 2R x 2.5Sq.mm + 1Rx 1.5Sq.mm for Primary & 3R x 1.5 for Secondary wiring FRLS 1100V wire of approved make drawn in Suitable dia Steel conduit including all conduit accessories such as bends, junction boxes etc., complete. The wiring shall be complete with ceiling roses, switches and all consumables. The wiring shall be complete with ceiling roses, switches and all consumables. The rate shall include providing mounting boxes with tapped holes for lights switches, moulded front plates with brass screws earthing of all points using third wire Conduit colour to be black in all closed ceiling and white in all open ceiling Point wiring for lights to be with connectors & flexible drops to be with proper sockets Any conduits crossing partitions/walls should have appropriate sleeves with fire sealant (fire sealant shall be in civll vendor scope) For concealed conduiting, wall chasing and finishing need to be considered in the quote.

-

-

-

... More
PRIMARY LIGHT POINT Supply, installation, Testing and Commissioning of point wiring using 2Rx2.5Sq.mm + 1Rx1.5Sq.mm FRLS 1100V wire of approved with Suitable dia Steel conduit including all accessories such as bends, junction boxes etc., complete. The wiring shall be complete with ceiling roses. The rate shall include providing mounting boxes with tapped holes for lights switches, moulded front plates with brass screws earthing of all points using third wire I. Primary light point means wiring from first switch control to the sensor, the first light outlet and to the subsequent next Switch/sensor in that circuit. The switch and all necessary accessories would be part of primary point. II. Not to include the incoming lighting circuit from MCB-DB to switch. III. 3 core PVC transparent clear electrical cable flex wire/cable shall be included at the drop of light fixture, flexibles with connectors and adaptors. IV. Consider Average Length - 10 Mtrs.

10

-

-

... More
Supply, installation, Testing and Commissioning of SECONDARY LIGHT POINT I. Secondary light point means extension of light outlet from existing primary point with Suitable dia Steel conduit with 3RX1.5 Sqmm FRLS 1100V wire. Same to be controlled by the existing switch/Sensor of primary point. II. 3 core PVC transparent clear electrical cable flex wire/cable shall be included at the drop of light fixture. III. Consider Average Length - 5Mtrs.

15

-

-

... More
POINT WIRING - MCB CONTROL Supply, installation, Testing and Commissioning of point wiring using 3R x 1.5Sq.mm for Secondary wiring FRLS 1100V wire of approved make drawn in Suitable dia Steel conduit including all conduit accessories such as bends, junction boxes etc., complete. The wiring shall be complete with ceiling roses and all consumables. DB to first light is measured under the circuit main Note: For staircase lighting - Concealed conduiting - PVC FRLS conduit needs to be considered. For concealed conduiting, wall chasing and finishing need to be considered in the quote.

-

-

-

... More
SECONDARY LIGHT POINT I. Secondary light point means extension of light outlet from existing primary point with ceiling rose & complete accessories. Same to be controlled by the existing MCB in DB II. 3 core PVC transparent clear electrical cable flex wire/cable shall be included at the drop of light fixture for power wiring III. Consider Average Lenght - 10 Mtrs.

2557.5

-

-

... More
Supply , Installation , Testing & Commisioining of Light & Power Wiring for Elevators (B2+B1+P1+P2+P3 - 5 Floors) comprising of following items mentioned below & Consider surface mounted conduiting with required all fixing accessories as required as per site conditions..The Quantity of below mentioned items shall be considered as per no.of Floors mentioned above of each lift & comprising of : - a. 12w LED Bulk Head - IP65 Protection b. 6A 3 Pin switched socket outlet c. Wiring for light points controlled by a 6A switch. d. Wiring for pit light using 2 Nos 6A 2 way switches. e. Wiring for sets of 6A switched & socket outlets. wire for lighting circuit : 3 runs of 1.5 sq.mm wire for power circuit : 3 runs of 4.0 sq.mm Conduit: 20mm Steel Conduit for lighting & 25 mm dia Steel Conduit for Power.

2

-

-

... More
Supply , Installation , Testing & Commisioining of Light & Power Wiring for Passenger Elevators (P1+1F+2F+3F+4F+5F+6F+7F+8F+9F-10Floors) & Service Elevators (B2+B1+P1+P2+P3+1F+2F+3F+4F+5F+6F+7F+8F+9F+TF - 15 Floors) comprising of following items mentioned below & Consider surface mounted conduiting with required all fixing accessories as required as per site conditions.The Quantity of below mentioned items shall be considered as per no.of Floors mentioned above of each lift & comprising of : - a. 12w LED Bulk Head - IP65 Protection b. 6A 3 Pin switched socket outlet c. Wiring for light points controlled by a 6A switch. d. Wiring for pit light using 2 Nos 6A 2 way switches. e. Wiring for sets of 6A switched & socket outlets. wire for lighting circuit : 3 runs of 1.5 sq.mm wire for power circuit : 3 runs of 4.0 sq.mm Conduit: 20mm Steel Conduit for lighting & 25 mm dia Steel Conduit for Power.

6

-

-

... More
WIRING FOR POWER MAIN POWER WIRING

-

-

-

... More
Supply, Laying, Testing and Commisiosning of 2R 6Sqmm + 1R 6 Sq..mm PVC insulated FRLS multistrand copper wire in Suitable dia Steel conduit with all accessories as required as per site conditions. For concealed conduiting, wall chasing and finishing need to be considered in the quote.

5396

-

-

... More
Supply, Laying, Testing and Commisiosning of 2R 4Sqmm + 1R 4Sq.mm PVC insulated FRLS multistrand copper wire in Suitable dia Steel conduit with all accessories as required as per site conditions. For concealed conduiting, wall chasing and finishing need to be considered in the quote.

24348.5

-

-

... More
Supply, Laying, Testing and Commisiosning of 2R 2.5Sqmm + 1R 2.5Sq.mm PVC insulated FRLS multistrand copper wire in Suitable dia Steel conduit with all accessories as required as per site conditions. For concealed conduiting, wall chasing and finishing need to be considered in the quote.

400

-

-

... More
POWER OUTLETS (SOCKETS) 'Supply, fixing, testing and commissioning of Modular Switch & Socket combination in suitable modular box with front plates ,blank plates,acessories wherever required in Open/Recessed system and Industrial Sockets with MCB in Open/Recessed system with necessary earthing arrangements.The necessary civil works shall be done for connected works and no extra payment will be made for the same. (On non availability of specified rating industrial sockets, immediate higher rating socket must be provided with given control breakers). The quoted rate shall be inclusive of approved make modular switches, accessories, surface box / metal box in open / recessed system. All industrial sockets should be provided with suitable plug. All metal box should be earthed as required & shall be covered with removable film coat to protect from scratches and paint.

-

-

-

... More
6/16A, 5pin, combination type shuttered switched socket outlet with indicator lamp and G.I outlet box and moulded plastic cover plate as required including termination of wires.

21

-

-

... More
1No. Of 10A socket controlled by 10A SP switch - Weather Proof (With Back box) - IP66

30

-

-

... More
1No. Of 6/16A socket controlled by 16A SP switch - Weather Proof (With Back box) - IP66

30

-

-

... More
1No. Of 6A socket controlled by 6A SP switch (Without Back box)

83

-

-

... More
2No. Of 6A socket controlled by 16A SP switch (Without Back box)

16

-

-

... More
3No. Of 6A socket controlled by 16A SP switch (Without Back box)

63

-

-

... More
1No. Of 6/16A socket controlled by 16A SP switch (With Back box)

950

-

-

... More
2Nos. Of 6A socket controlled by 16A SP switch (With Back box)

8

-

-

... More
3Nos. Of 6A socket controlled by 16A SP switch (With Back box)

10

-

-

... More
1No. Of 16A 3 pin single phase Industrial type socket with plug top controlled by 16A DP MCB

10

-

-

... More
1No. Of 63A 5 pin single phase Industrial type socket with plug top controlled by 63A 4P MCB

6

-

-

... More
1No. Of 32A 3 pin single phase Industrial type socket with plug top controlled by 32A DP MCB

10

-

-

... More
1No. 16A Single pole switch for Tenant area Lighting

41

-

-

... More
Supply, Fixing, Testing and Commissioning of 3KVA 1 phase UPS - 230 volt ,50 hz, AC input and output 230 volt AC ,50 hz,sine wave ; 2Hours. full load Back-up with maintenance free battery with stand and other associated accessories as required as per the site conditions.

2

-

-

... More
Supply, Fixing, Testing and Commissioning of 32A DP MCB enclosed in weather proof MS Enclosure with and other associated accessories as required as per the site conditions (Master Control MCB)

16

-

-

... More
Supply and installation of 20A 3 Pin 1 phase industrial socket controlled by 20A DP MCB

31

-

-

... More
Supply and installation of Readymade floor mounted Junction box - To locate 1 Set of 4 x 6A socket + 1no of 16A Switch and 4 Data outlets (12 Module) Cost need to include power outlets + Data outlets

4

-

-

... More
Supply and installation of 1No. Of 6A socket controlled by 6A SP switch (With Back box)

347.7

-

-

... More
Supply, Fixing, Testing and Commissioning of 3.7kW AC Single phase EV charger with plug top & all accessories. in weather proof MS Enclosure with and other associated accessories as required as per the site conditions

61

-

-

... More
Supply, Fixing, Testing and Commissioning of 11kW AC Three phase EV charger with plug top & all accessories. in weather proof MS Enclosure with and other associated accessories as required as per the site conditions

11

-

-

... More
Supply, Fixing, Testing and Commissioning of 22.5kW DC Three phase EV charger with plug top & all accessories. in weather proof MS Enclosure with and other associated accessories as required as per the site conditions

1

-

-

... More
Supplying and fixing 1 or 2 Module (75mmX75mm) size GI box alongwith modular base & cover plate for modular switches in recess etc. as required.

86

-

-

... More
Supplying and fixing 4 Module (125mmX75mm) size GI box along with modular base & cover plate for modular switches in recess etc. as required.

160

-

-

... More
Supplying and fixing 6 Module (200mmX75mm) size GI box along with modular base & cover plate for modular switches in recess etc. as required.

125

-

-

... More
Supplying and fixing 8 Module (125mmX125mm) size GI box along with modular base & cover plate for modular switches in recess etc. as required.

112

-

-

... More
Supplying and fixing 12Module (200mmX150mm) size GI box along with modular base & cover plate for modular switches in recess etc. as required.

40

-

-

... More
CABLE TRAY Supply, fabrication, installation & painting of Hot Dip galvanized (65 - 70 Micron as per IS2629) Ladder cable racks / trays of up to 300 ( 1.6mm thickness ) & more than 300mm up to 750mm (2 mm thickness) more than or equal to 1000mm ( 2.5 thickness) with necessary painted G.I structural supports in horizontal or vertical formation & single / multitier formation as specified and shown on drawings. Up to 450mm - cable trays shall be supplied along with rod and C channel, refer specifications. Above 450mm cable tray support shall be with suitable angle supports as per specifications. The rate shall include GI supports, bends, Tees, all supporting brackets, anchor fasteners, screws, bolts, nuts etc. The Proper Floor supports need to be considered for the terrace floor cable tray as per the drawing. Supply, fabrication, installation & painting of Hot Dip galvanized (65 - 70 Micron as per IS2629) Ladder cable racks / trays of up to 300 ( 1.6mm thickness ) & more than 300mm up to 750mm (2 mm thickness) more than or equal to 1000mm ( 2.5 thickness) with necessary painted G.I structural supports in horizontal or vertical formation & single / multitier formation as specified and shown on drawings.

-

-

-

... More
100X50mm Cable Tray

10

-

-

... More
150X50mm Cable Tray

30

-

-

... More
200X50mm Cable Tray

30

-

-

... More
300X50mm Cable Tray

30

-

-

... More
450X50mm Cable Tray

369

-

-

... More
600X75mm Cable Tray

141

-

-

... More
750X75mm Cable Tray

405

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness 65 - 70 Micron as per IS2629) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. as specified and shown on drawings. Up to 450mm - cable trays shall be supplied along with rod and C channel, refer specifications. Above 450mm cable tray support shall be with suitable angle supports as per specifications.

-

-

-

... More
100 mm width X 50 mm depth X 1.6 mm thickness

737

-

-

... More
150 mm width X 50 mm depth X 1.6 mm thickness

1493

-

-

... More
225mm width X 50 mm depth X 1.6 mm thickness

477

-

-

... More
300 mm width X 50 mm depth X 1.6 mm thickness

505

-

-

... More
450 mm width X 62.5 mm depth X 2.0 mm thickness

494.45

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.

-

-

-

... More
100 mm width X 50 mm depth X 1.6 mm thickness

37

-

-

... More
150 mm width X 50 mm depth X 1.6 mm thickness

81

-

-

... More
225mm width X 50 mm depth X 1.6 mm thickness

30

-

-

... More
300 mm width X 50 mm depth X 1.6 mm thickness

28

-

-

... More
450 mm width X 62.5 mm depth X 2.0 mm thickness

28

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.

-

-

-

... More
100 mm width X 50 mm depth X 1.6 mm thickness

25

-

-

... More
150 mm width X 50 mm depth X 1.6 mm thickness

50

-

-

... More
225mm width X 50 mm depth X 1.6 mm thickness

17

-

-

... More
300 mm width X 50 mm depth X 1.6 mm thickness

16

-

-

... More
450 mm width X 62.5 mm depth X 2.0 mm thickness

26

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Cross member"(galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.

-

-

-

... More
100 mm width X 50 mm depth X 1.6 mm thickness

25

-

-

... More
150 mm width X 50 mm depth X 1.6 mm thickness

50

-

-

... More
225mm width X 50 mm depth X 1.6 mm thickness

16

-

-

... More
300 mm width X 50 mm depth X 1.6 mm thickness

13

-

-

... More
450 mm width X 62.5 mm depth X 2.0 mm thickness

21

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Reducer"(galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.

-

-

-

... More
100 mm width X 50 mm depth X 1.6 mm thickness

25

-

-

... More
150 mm width X 50 mm depth X 1.6 mm thickness

50

-

-

... More
225mm width X 50 mm depth X 1.6 mm thickness

16

-

-

... More
300 mm width X 50 mm depth X 1.6 mm thickness

13

-

-

... More
450 mm width X 62.5 mm depth X 2.0 mm thickness

21

-

-

... More
RACEWAY - FLOOR Supply & Installation of following size Pregalvanized - GI raceway / wire way with cover, made out of 16 SWG for body and 14 SWG for cover. Junction boxes to be provided with enough supports inside the box. Raceway installed above false ceiling/floor shall include necessary mounting supports, junction boxes and accessories to fix it firmly to the ground/ ceiling. The raceways shall be fixed to the floor with GI/MS (25mm x 3mm) strips so that there is no movement of the channels when civil work (pouring of cement concrete) is being done. Rate includes necessary floor cutting and chipping with machine of minimum 50mm depth, removal of debris out of site and neatly finished with M15 grade concrete up to the finished floor level. Race ways to be covered with Chicken mesh before concreting. Curing compound to be applied after initial setting of the concrete. All edges, cut faces shall be free of burrs & shall be smooth. The channels shall be earthed at the boxes and at the joints with 14 SWG bare copper wire with screws so that earth is continuous. Jointing of the race ways to be done with welding.

-

-

-

... More
Junction boxes - Floor

-

-

-

... More
i)90 x 90 x 50mm Size

77

-

-

... More
ii)110 x 110 x 50mm Size

20

-

-

... More
iii)160 x 160 x 50mm Size

10

-

-

... More
iv)210 x 210 x 50mm Size

9

-

-

... More
v)260 x 260 x 50mm Size

5

-

-

... More
vi)310 x 310 x 50mm Size

5

-

-

... More
vii)410 x 410 x 50mm Size

8

-

-

... More
Floor Raceways : 'Supply & Installation of following size Pre galvanised raceway with above specified worksgiven in item no.29

-

-

-

... More
50 x 38mm Size

92

-

-

... More
100 x 38mm Size

50

-

-

... More
150 x 38mm Size

32

-

-

... More
200 x 38mm Size

23

-

-

... More
250 x 38mm Size

10

-

-

... More
300 x 38mm Size

24

-

-

... More
400 x 38mm Size

10

-

-

... More
Supply and Installation of Powdered coated box trays made of 2m thick GI sheet and top removable cover with 2mm thick sheet as required. The rate shall include the joint pieces which made of 2mm thick GI sheet as required. The distribution raceways only shall be provided with 25/32/40mm knockouts wherever required. also the cost shall inclusive of necessary fixing accessories.(powdered coated colour shall be approved by architect).

-

-

-

... More
150 x 75 x 2 mm

10

-

-

... More
200 x 75 x 2 mm

10

-

-

... More
300 x75 x 2 mm

10

-

-

... More
RACEWAY - CEILING 'Supply & Installation of following size Powder coated Galvanized - GI (65 - 70 Micron as per IS2629) raceway / wire way with cover, made out of 14 SWG GI for body and 14 SWG GI for cover. Junction boxes to be provided with enough supports inside the box. Raceway installed above false ceiling shall include necessary mounting supports, junction boxes and accessories to fix it firmly to the ceiling. All edges, cut faces shall be free of burrs & shall be smooth. The channels shall be earthed at the boxes and at the joints with 14 SWG bare copper wire with screws so that earth is continuous. Jointing of the race ways to be done using fisher plates & 'Slotted Channel' angle supports @ 600mm interval etc., to suit site conditions. Colour of the raceways should be as per Interior views / Finalised by Project Officer during GFC stage

-

-

-

... More
Junction boxes - Ceiling

-

-

-

... More
90 x 90 x 50mm Size

16

-

-

... More
110 x 110 x 50mm Size

24

-

-

... More
160 x 160 x 50mm Size

13

-

-

... More
210 x 210 x 50mm Size

19

-

-

... More
260 x 260 x 50mm Size

5

-

-

... More
310 x 310 x 50mm Size

9

-

-

... More
410 x 410 x 50mm Size

5

-

-

... More
CEILING RACEWAYS : 'Supply & Installation of following size Pre galvanised raceway with above specified worksgiven in item no.32

-

-

-

... More
50 x 38mm Size

50

-

-

... More
100 x 38mm Size

160

-

-

... More
150 x 38mm Size

78

-

-

... More
200 x 38mm Size

98

-

-

... More
250 x 38mm Size

10

-

-

... More
300 x 38mm Size

61

-

-

... More
400 x 38mm Size

10

-

-

... More
ASSOCIATED ACCESSORIES Supply and fixing of haeavy duty PVC& heavy duty Steel conduit of various dia., exposed or concealed, with all accessories, Wall chasing, finishing, fish wire, etc., as directed by the departmental officers and the brand should got approval. (Exposed Conduiting - Steel & Concealed Conduiting - PVC)

-

-

-

... More
32mm PVC Conduits

200

-

-

... More
25mm PVC Conduits

1550

-

-

... More
20mm steel Conduits

1650

-

-

... More
25mm steel Conduits

1700

-

-

... More
32mm steel Conduits

350

-

-

... More
Supply, fabrication and installation of MS structural supports including welding, bolting, riveting, supply of necessary anchor bolts and grouting etc, supply of paint and applying one coat of anti rust primer and two finished coats of approved synthetic enamel paint including breaking walls, floors etc. for structures as required including supply of all GI hardware materials, including all labour and materials as per approved drawings, specifications of this tender and directions of Project Officer`s-in-Charge.

8

-

-

... More
Supply and arranging for Temporary Power Supply for lighting and other contract agencies at site including sufficient no of tube light fittings, sufficient no. of plug points with plug tops with adequate distribution boards and all other necessary safety devices like elcb, etc., to ensure safe and continued supply at site. up to end of the project. as directed by the departmental officers and the brand should be got approval.

1

-

-

... More
Supply & installation of 150mm wide x 100mm depth MS Powder coated 18G DB cabinet/Camouflaging

375

-

-

... More
RCC Half cut Hume pipe of following size 900mm below ground level, including collars & civil works.

-

-

-

... More
150mm Dia

9

-

-

... More
200mm Dia

80

-

-

... More
300mm Dia

10

-

-

... More
SHOP DRAWINGS, INSPECTION AND APPROVALS

-

-

-

... More
Preparation & submission of applications, Liasioning with EB for getting addtional Load sanction, all necessary co-ordination upto completion of the project.

1

-

-

... More
Preparation of CEIG drawings, Liasioning with CEIG for getting drawing approval, arranging inspection, getting safety certificate & preparation& submission of AS BUILT drawings. Four Sets of paper print of as built drawings& a soft copy of these drawings to be submitted to the clients while completion. (All statutory fees to be paid in this regard will be reimbursed by the client on submission of receipt & should not be included in this item). Including DG sets approvals.

1

-

-

... More
EARTH FLAT BUS

-

-

-

... More
Supply & Laying of 50x6mm GI. Flat for grounding connections in supports,trays,surface , using necessary fixing materials,insulators at regular intervals as required. The cost shall include minor civil works.

690

-

-

... More
Supply & Laying of 50x6mm CU. Flat for grounding connections in supports,trays,surface , using necessary fixing materials,insulators at regular intervals as required. The cost shall include minor civil works.

183

-

-

... More
Supply & Laying of 25x6mm CU. Flat for grounding connections in supports,trays,surface , using necessary fixing materials,insulators at regular intervals as required. The cost shall include minor civil works.

305

-

-

... More
Supply & Laying of 25x3mm GI. Flat for grounding connections in supports,trays,surface , using necessary fixing materials,insulators at regular intervals as required. The cost shall include minor civil works.

5491.5

-

-

... More
Supply & Laying of 25x6mm GI. Flat for grounding connections in supports,trays,surface , using necessary fixing materials,insulators at regular intervals as required. The cost shall include minor civil works.

1753.5

-

-

... More
Supply & Laying of 6 Sq.mm. Cu. Wire for grounding connections in supports,trays,surface , using necessary fixing materials,insulators at regular intervals as required. The cost shall include minor civil works.

1228.5

-

-

... More
Supply & Installation of Busbar of 0.5 Mtr length made out of 50x6 mm GI strip with drill holes of M8 at 25mm interval mounted on insulators with Enclosure Box with visible glass

5

-

-

... More
Supply & Installation of Busbar of 0.5 Mtr length made out of 25x6 mm GI strip with drill holes of M8 at 25mm interval mounted on insulators with Enclosure Box with front visible glass

45.85

-

-

... More
Supply & Installation of Busbar of 0.5 Mtr length made out of 25x6 mm Cu strip with drill holes of M8 at 25mm interval mounted on insulators with Enclosure Box with front visible glass

4

-

-

... More
Supply,installation, testing and commissioning of GI Pipe Electrode Earthing System:Pipe Earth Electrode using 38 mm dia class B GI pipe complete as per IS 3043 with salt, charcoal, brick masonary chamber with heavy duty RCC cover (suitable to take fire tender load) tender truckmovement) of 450mm x 450mm x 300mm chamber. (Earth strip to be left upto the Earthpit for Connection) The rates shall include excavation of the pit, construction of masonry chamber, providing heavy duty concrete cast slab, painting & making etc.,& as per the technical specification. The supporting pipe, funnel sizes, etc as per NBC.

12

-

-

... More
Supply,installation, testing and commissioning of Copper plate Electrode Earthing System:Plate Earth Electrode using 19 mm dia  Class B  copper plate of size 600 x 600 x 3 mm thick.with heavy duty RCC cover (suitable to take fire tender truck load) of 450mm x 450mm x 300mm chamber.(Earth strip to be left upto the Earthpit for Connection) The rates shall include excavation of the pit, construction of masonry chamber, providing heavy duty concrete cast slab, painting & making etc.,& as per the technical specification. The supporting pipe, funnel sizes, etc as per NBC.

8

-

-

... More
UPS & BATTERY

-

-

-

... More
Design, manufacture, assembly, supply, installation, testing, delivery and commissioning of 30 kVA (Continuous rating) online, double conversion operating on conventional mode 3 ph input and 3 ph output UPS system with IGBT rectifier without isolation transformer as per technical specifications. complete with all accessories and fire/over temperature detection, control/Display panel & energy optimization feature. The system shall be housed in sheet steel enclosure fabricated out of standard thickness. The enclosure with IP 20 protection shall have ventilation fans on top , provision for cable entry from bottom and remote alarm panel compatibility. The unit shall have BACnet IP communication interface. The quoted rate shall be inclusive of the tests and all other accessories specified in technical specification. The THD of UPS units shall be less than 3%. (For COMMAND CENTER)

2

-

-

... More
Supply, installation, testing and commissioning of Battery banks of requisite quantity and AH rating suitable for 30 kVA (Continuous rating) online, double conversion UPS system with one suitably rated DC circuit breaker on each string with all necessary nterconnecting links and interconnecting copper cables for each of above UPS units with 30 minutes back up at rated load. Battery shall be of the sealed maintenance free Valve Regulated Lead Acid (VRLA) stationary type 12V blocks conforming to technical specification.

2

-

-

... More
Design, manufacture, assembly, supply, installation, testing, delivery and commissioning of 40 kVA (Continuous rating) online, double conversion operating on conventional mode 3 ph input and 3 ph output UPS system with IGBT rectifier without isolation transformer as per technical specifications. complete with all accessories and fire/over temperature detection, control/Display panel & energy optimization feature. The system shall be housed in sheet steel enclosure fabricated out of standard thickness. The enclosure with IP 20 protection shall have ventilation fans on top , provision for cable entry from bottom and remote alarm panel compatibility. The unit shall have BACnet IP communication interface. The quoted rate shall be inclusive of the tests and all other accessories specified in technical specification. The THD of UPS units shall be less than 3%. (For Security & office related power points)

2

-

-

... More
Supply, installation, testing and commissioning of Battery banks of requisite quantity and AH rating suitable for 40 kVA (Continuous rating) online, double conversion UPS system with one suitably rated DC circuit breaker on each string with all necessary nterconnecting links and interconnecting copper cables for each of above UPS units with 30 minutes back up at rated load. Battery shall be of the sealed maintenance free Valve Regulated Lead Acid (VRLA) stationary type 12V blocks conforming to technical specification.

2

-

-

... More
Design, manufacture, assembly, supply, installation, testing, delivery and commissioning of 25 kVA (Continuous rating) online, double conversion operating on conventional mode 3 ph input and 3 ph output UPS system with IGBT rectifier without isolation transformer as per technical specifications. complete with all accessories and fire/over temperature detection, control/Display panel & energy optimization feature. The system shall be housed in sheet steel enclosure fabricated out of standard thickness. The enclosure with IP 20 protection shall have ventilation fans on top , provision for cable entry from bottom and remote alarm panel compatibility. The unit shall have BACnet IP communication interface. The quoted rate shall be inclusive of the tests and all other accessories specified in technical specification. The THD of UPS units shall be less than 3%. (For Emergency lighting )

1

-

-

... More
Supply, installation, testing and commissioning of Battery banks of requisite quantity and AH rating suitable for 25 kVA (Continuous rating) online, double conversion UPS system with one suitably rated DC circuit breaker on each string with all necessary interconnecting links and interconnecting copper cables for each of above UPS units with 90 minutes back up at rated load. Battery shall be of the sealed maintenance free Valve Regulated Lead Acid (VRLA) stationary type 12V blocks conforming to technical specification.

1

-

-

... More
BATTERY RACK Supply and installation of Battery Rack of epoxy painted sheet steel suitable for above mentioned UPS battery banks rating with separate compartment for circuit breaker. Each rack shall be supplied with 150mm high MS base stand . Cost includes of fabricated MS frame approximately 300mm height suitable for UPS Battery. The design of stool shall ensure uniform distribution of weight of 400kg/Sqm

-

-

-

... More
40 KVA

2

-

-

... More
30 KVA

2

-

-

... More
25 KVA

1

-

-

... More
MISCELLANEOUS ITEMS

-

-

-

... More
Supply of AC Chargeable Emergency Lamp 2 x 11W LED Lamp with all connected accessories

3

-

-

... More
Supply and installation of 2m x 1m Rubber Mat suitable for 11 KV installation confirming to IS

60.9

-

-

... More
Supply and installation of framed first aid chart (English & Local language) in panel room

21

-

-

... More
Supply and installation of First Aid Box complete with all First Aid Medicines

21

-

-

... More
Supply and installation of Shock Treatment Chart fixed in glass frame

21

-

-

... More
Supply of Hand Gloves 11KV Grade

5

-

-

... More
Supply & installation of 11 KV Danger boards

2

-

-

... More
Supply & installation of 440V Danger boards

26.25

-

-

... More
Supply & installation of 4 Nos. Fire Buckets made out of 40 x 40 x 6mm MS Angle

4

-

-

... More
Supply and installation of Fire Extinguisher Co2, 4.5 kg. confirming to TAC Norms

6

-

-

... More
Supply and installation of framed, Laminated SLD in Electrical rooms

19

-

-

... More
Supply & Installation of HT / LT cable route marker complete as per Latest Standards & regulations

11

-

-

... More
Supply of 2 hour fire rated fire retardant material sealing (UL Listed) all electrical ducts and openings made in the slab / wall / partition to take conduits / cable trays / raceways etc as required complete / as directed by the site incharge

25.2

-

-

... More
Supply & Installation of Double wall corrugated HDPE pipes of 6 Kg/Cm2 working pressure   including all accessories i.e. bends, reducers, flanges as required of following sizes

-

-

-

... More
50 mm OD with 3.6 mm wall

60

-

-

... More
100 mm OD with 5.5 mm wall

60

-

-

... More
160 mm OD with 7.7 mm wall

30

-

-

... More
300mm OD with 12.0 mm wall

30

-

-

... More
Battery Charger - Indoor Supply , installation,testing & commissioning of Thyristor controlled Float cum boost charger having output suitable for 24volt DC 100 AH SMF battery with metering to measure output current & battery charging/discharging current with RYB indication (mains on R,Y,B Charger on, float & boost mode),alarm for battery Earth leakage & battery overvoltage, autochangeover from Float to boost & vice versa with timer, selector switch to operate float cum boost charger in Boost mode in suitable 1.6 mm sheet steel cabinet with RAL 7032 Epoxy painted enclosure complete including one no. distribution board having Suitable rating of MCCB as incomer and 20Nos. 20/16A DP MCB's (D.C. duty) as outgoings complete as required in all respect as per approved drawings, specifications of this tender and directions of project officer incharge

1

-

-

... More
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE Energy efficient 1200mm Sweep Ceiling Fan 5 Star Rated, inverter driven controlled by microprocessor with 300mm down rod with regulator / remote control (35 W)

5

-

-

... More
Supply, Installation, Testing and Commissioning of 300mm dia. Box type single phase heavy duty exhaust fan with suitable louvers as required as per site conditions

5

-

-

... More
Supply,Installation, Testing & Commissioning of façade lighting

-

-

-

... More
Supply, Installation, Testing and Commissioning of LED Striplight Outdoor RGBW(W=3000K), IP67, 19.2W/m, 5000mmx12mmx2mm, 24V, 19.2W/m, with L7050000 Burning Hours and 5 years Warranty with fixing accessories as required

700

-

-

... More
Supply, Installation, Testing and Commissioning of CV DMX RDM Decoder - 4 channel, 8Amp, DMX512/RDM CV Decoder with fixing accessories as required

279

-

-

... More
Supply of Surface Mount Aluminum Profile and PC diffuser with Endcap and Mounting clip (2 sets/M).W: 16mm X H: 18mm Standard length -3 meter. with fixing accessories as required

1167

-

-

... More
Supply, Installation, Testing and Commissioning of 250W 24V Constant Voltage Outdoor Driver with fixing accessories as required

269

-

-

... More
Supply, Installation, Testing and Commissioning of 75W 24V Constant Voltage Outdoor Driver with fixing accessories as required

10

-

-

... More
Supply, installation, testing and commissioning of compact DMX signal splitter that takes the incoming DMX512/RDM signal and amplify the signal and supporting bi-directional communications for discovery, addressing and DMX control of light fixtures.This unit takes the incoming DMX/RDM signal and splits the signal into six separate output channels allowing for expanding the number of devices controlled from 32 to 6 X 32. The output terminals are electronically isolated from the input & RDM-through port and share a common ground reference. All six output ports have an independent output driver to boost the DMX/RDM signal. The maximum power consumption shall be less than 4.5W and input voltage shall be 12-24V DC.

60

-

-

... More
Supply, installation, testing and commissioning of controller along with required communication cables to author, configure, and control dynamic LED light shows for DMX lighting networks. Its shall be a compact yet powerful show storage and playback device capable of delivering light shows up to 8 DMX512 universes. Controller should have custom show authoring capabilities, an intuitive LCD interface, removable SD card storage. The controller should have 2 no's of RJ45 input port. It should operating on 12V DC supply from a additional power supply device. Controller Supported LED Nodes should be 8 universes of 512 DMX addresses each. Operating temp -30 to 50° C. Power consumption 8W max. The humidity range shall be 10 to 90% and IP20.

1

-

-

... More
Design, Supply, Loading, Unloading, Installation, Testing & Commissioning of 130kW SOLAR ROOFTOP SYSTEM with the following items/works

-

-

-

... More
Solar PV - Mono Perc Crystalline Type Panels of Minimum 540 Wp

240

-

-

... More
Solar generation meter - (Unidirectional type, Immediate to LT panel) as per TANGEDCO norms

1

-

-

... More
11kv net meter (Bidirectional) procurement and approvals as per TANGEDCO norms

1

-

-

... More
Remote Monitoring system of Solar PV Power plant with necessary communication system setup

1

-

-

... More
Inverter- Three Phase, BIS approved - String Inverter, 130kW (Combination of single or multiple Inverter)

1

-

-

... More
Module Mounting Structure (MMS)-Front and Back post type alongwith HDGI type with GI (Minimum 85 Micros) ,SS fasteners, uPVC Conduit pipes, Cable Tray , MC4 Connectors (pair set) and others like DC+AC Consumables ( Earthing Cables, Cable tie, markers, MC4 Crimping tool, Ferrules etc), Anti corrosion material should be used.

1

-

-

... More
String Cable (Inverter at Roof top itself) - 4 sqmm cable as required

1

-

-

... More
DC Distribution Board /Panel - Based on design, DC Fuse and SPD Type II

1

-

-

... More
AC Distribution Board /Panel - as per design topology, with SPD-AC - Indoor type

1

-

-

... More
Earthing system as required

1

-

-

... More
AC cable FRLS -3C X 185 sqmm, Aluminium ,XLPE

1

-

-

... More
End termination glands as required as per design

1

-

-

... More
Civil work for MMS as required as per Site conditions

1

-

-

... More
Safety Items, First Aid Box and Posters

1

-

-

... More
CEIG approval for Solar system

1

-

-

... More
Feasibilty, Statuary approvals and Coordination with TANGEDCO for Solar PV plant till commissioning

1

-

-

... More
SITC OF DG SETS

-

-

-

... More
Supply, Loading, Unloading, Installation & Commissioning as desired by Project Officer`s-in-charge, Testing and Commissioning of 3 Phase 415 Volts 50 cycle per second, 1500 RPM Prime Rated Diesel Generator Set with PCC 3.3, Radiator Fan Cooled Diesel Generator Sets. The engine shall be complete with turbo charger, flywheel to suit flexible coupling with guard, air cleaner, blower fan, fuel pump, variable speed electronic governor, fuel filter, lube oil filter and pump, primary water circulating pumps, battery charger, 24 volt batteries of compatible capacity, MS battery stand and instrument panel comprising of switch with key, lube oil pressure gauge, water temperature gauge, battery charging voltmeter, safety control for low lube oil pressure, over speed and high cooling water temperature with tripping. The alternator shall be self excited, self regulated, brushless and continuously rated for kVA at 0.8 P.F., 3 phase 415 volts, 50 cycle per second, 4 wire system and shall be provided with static excitation unit. Alternator insulation shall be class 'H' suitable to withstand tropical conditions and shall generally comply with latest up to date amendment to IS Code. The overload capacity shall not be less than 110% of rated capacity for 1 hour in every 12 hours. The DG Set shall be mounted on a fabricated rigid common base frame with anti-vibration mountings to provide 98% vibration isolation. The DG set shall include all accessories, fittings, instruments and standard tool kit complete as per specification and as required including control cabling. The cost shall include providing and fixing adaptor box for cable termination as required. The Alternator shall be compatible to be synchronized to the Main LT Panel through controllers of approved make. The D.G. sets shall be inclusive of but not limited to the following standard accessories: Radiator Fan cooling system Fly Wheel to suit flexible/rigid coupling Fly wheel housing complete with starter gear ring and coupling Fuel hoses Electronic Governor Air Cleaner with Vacuum Indicator Fuel and Lube Oil Filter By pass filter Fuel Pump PT Type Water Pump Lube Oil Pump Electric Starter 24 Volts DC Battery Charging Alternator with Built-in-regulator - 24 Volts, 50 Amps. and battery stand

-

-

-

... More
Safety Control against low lube oil pressure, over speed and high cooling water temperature along with tripping Vibration Dampers Lube Oil Cooler Flue pipe of required size from DG set FLUE OUTLET up to Silencer Residential Silencer Expansion bellow -( suitable size SS bellows) Anti Vibration Pads with spring vibration Isolator First fill of Lube Oil (Castrol/HPL/IOCL) and Coolant qty as per engine requirement Control Panel with Synchronisation and load sharing option Sync. Controller & Control Cabling as Standard System Integration (b/w Dg set on Synch controller) Batteries with battery leads along with battery stand

-

-

-

... More
DG SET WITHOUT ACOUSTIC ENCLOSURE: Latest CPCB norms should be followed.

-

-

-

... More
2000 KVA DG SET WITHOUT ACOUSTIC ENCLOSURE

3

-

-

... More
Engine Mounted ACB enclosures:

-

-

-

... More
DG isolator Panel As per SLD shall be mounted on the alternator with necessary supports, anti-vibration connections, mounting brackets, MS stand, clamps etc. and suitable size of flexible copper bus bars / univyn cables between DG alternator terminal to the box along with 3200A 4 Pole ACB.

3

-

-

... More
DG Sets shall include one day fuel tank (990 litres) for each DG set. The day fuel tank shall be fabricated from 2 mm thick MS sheets and shall include the cost of removable cover with locking arrangement, the cost of painting, the cost of providing all the required appurtenances like inlet & outlet connection, float valves, drain connection, oil level indicator and low level/high level alarms and the cost of support arrangement. complete as per specification and as required. Level indicator shall be compatible to BMS integration.

5

-

-

... More
Piping for fuel System:

-

-

-

... More
Suppply & Installation of HSD piping (Heavy Duty Class- 'C') MS ASTM 106 grade B schedule 40 seamless pipe with all accessories/ fittings such as bends,tees unions etc, including necessary G.I. supprts, cutting, welding, Painting with one coat of primer and two coats of enamel paint of approved make. The quoted rate to include all necessary hardware, electrostatic jumpers for all flange joints, Cost of all necessary flanges/matching flanges,Reducers for suction & delivery lines to be included i) G.I. Supports, brackets for piping with all joints, supports etc. ii) installation of pipes in hume pipe laid for road crossing , trenches in DG Room , External trench with all necessary accesories for its complete installation as per IS standrads.

-

-

-

... More
MS pipes

-

-

-

... More
40 mm dia

20

-

-

... More
50 mm dia

100

-

-

... More
Ball valves

-

-

-

... More
25 mm Dia Ball Valves

3

-

-

... More
50 mm Dia Ball Valves

15

-

-

... More
Design, Supply, Installation, Testing and Commissioning of Level switch/Transmitter with provision of connect to PLC/BMS system in intermediate /over flow day tanks

-

-

-

... More
Butterfly Valve as per the specification for following dia

-

-

-

... More
80 mm dia

3

-

-

... More
65 mm dia

3

-

-

... More
Non Return Valve as per the specification for following dia

-

-

-

... More
80 mm dia

2

-

-

... More
65 mm dia

2

-

-

... More
50 mm dia

2

-

-

... More
40 mm dia

2

-

-

... More
25 mm dia

2

-

-

... More
Strainer

2

-

-

... More
Flow Meter 38 MM

3

-

-

... More
Flow Meter 50 mm

3

-

-

... More
Roto Del GearFlame Proof Motor HG 75

2

-

-

... More
Roto Del Gear flame proof pump HG 30

2

-

-

... More
High low level Sensor 3 Stage

4

-

-

... More
High low level Sensor 2 Stage

4

-

-

... More
Fuel level Transmitter

3

-

-

... More
Float Valve

4

-

-

... More
Design, Supply, Installation, Testing and Commissioning of DG room Exhaust fans ( 6000cfm) for removing the DG skin heat and room ventilation. The fan shall be Vane Axial type, suitable 415 v three phase motor and noise level sahll be 65 dBa at three meter distance. DG vendor should submit the necessary fan sizing calaculation for approval

6

-

-

... More
Supply ,installation ,Testing and commissioning of Retrofit Emission control device suitable for 2000 KVA, 415 Volts prime rating diesel generating set, as per the commission for air quality management and their recent directions, RECD should match the emission control criteria, Smoke shall not exceed prescribe value throughout the operating load points of the test cycle, as per the latest directions by CAQM/State pollution control board/CPCB & NGT suitable for 2000 KVA, 415 volts DG set. RECD shall have no effect on exhaust back pressure. The back pressure shall be maintained within prescribed limit by the manufacturer. There should not be any backflow from RECD to engine exhaust system. Type Approval of RECD for family of DG Sets should be as per CPCB instructions and the same has to be obtained from the CPCB prescribed labs . Any other equipments required with RECD to comply the CAQM criteria required to be consider in this Item only.The RECD shall be certified by one of the approved & recognised agencies by the central air pollution control board. RECD should have IoT based controller to remotly measure the parameters by the pollution control board website directly as and when required, also should have communication port for BMS through backnet over IP with open protocol connectivity. Retrofit Emission Control device (RECD) in suitable weather proof canopy with suitable provision for termination of IN and OUT of exhaust pipes ( including the manifolds if required for connection) to meet the local standards etc. The system shall be complete with all accessories including cabling, termination, outdoor MCC panel including necessary power cabling , earthing etc. as per the technical specification (IF THIS ITEM IS NOT REQUIRED BY THE VENDOR & THEY ARE FULFILLING THE LATEST CAQM CRITERIA OF EMMISSION CONTROL, THEN CONFRIMATION FROM OEM SHALL BE SUBMITTED)

3

-

-

... More
Exhaust System

-

-

-

... More
Design, Supply, Installation, Testing and Commissioning of Self-supporting M.S Class B or 5mm thick DG Exhaust Pipes as specified & complete with all M.S supporting structures, sampling point, two coats of red oxide and anti corrosive painting, necessary anti-vibration supports, floor brackets, required insulation of 100mm thickness having density of 48 Kg/ M3 wrapped in chicken mesh and cladding as with 24 gauge alluminium sheet specified including erection. Expansion bellows shall be provided at necessary location. The diameter of the exhaust pipe has to be decided by DG vendors considering the horizontal and vertical length, bends involved to take required height for discharge as per CPCB norms.Back pressure calculation has to be submitted by DG vendor and get approved from Project Officer`ss incharge. Latest CPCB norms should be followed.

-

-

-

... More
Exhaust pipe

-

-

-

... More
400mm dia. Exhaust Pipe

5

-

-

... More
500mm dia. Exhaust Pipe

5

-

-

... More
600mm dia. Exhaust Pipe

254

-

-

... More
Silencer

-

-

-

... More
Silencer Insulation 50mm thick lightly resin bonded (LRB) rock wool (64 Kg/m3 density) insulation clad with 26 SWG aluminium sheet cladding.

6

-

-

... More
Steel Items

-

-

-

... More
MS supports

-

-

-

... More
Supply, Fabrication, Commissioning and Erection of MS steel structure & painting with two coats of primer zinc oxide and two coats of approved enamel paint. All MS supports shall be measured in this line item (Cable tray, DG Stack, DG room Accoustic & DG day tank Supports) Quoted price shall be inclusive of Supporting arrangement at all levels & for the metal deck slab shall be with Wedge/ Gripple / Lindapter / fischer fixing arrangement for TR 60 / TR 80 metal decks. (Vendor has to submit Structural design calculation and all necessary supports within the building area shall be reviewed and confirmed by Project Officer before execution.

15

-

-

... More
Supply, and fixing of SS flexible bellows-300 mm dia

6

-

-

... More
Supply, and fixing of SS flexible bellows-500 mm dia

2

-

-

... More
DG PANEL & ADOPTER BOX

-

-

-

... More
Supply, erection, testing and commissioning of 415V, 3 phase 4 wire 50 c/s, fully compartmentalized cubical type, fabricated with CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having required capacity extensible type FP Copper alloy bus bars of high conductivity, DMC / SMC bus bars of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 65kA/50kA for 1 Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, Form of separation shall be form 4b with metallic separation only entire panel shall have a common copper earth bar of size 50 mm x 6 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Al/Cu. bus bars, interconnection, interlocking between feeders etc.,

-

-

-

... More
Annuntiation window requirement shall be as per SLD. with indication lamps, push buttons necessary accessories, complete with following incoming and outgoing switchgears with protection and metering etc. as per specification and schematic diagram including provision to be made for interfacing with BMS etc. complete as required with incoming & outgoing cable entry from bottom/top and bus-duct entry from top, wiring with 2.5sq. mm. PVC insulated copper conductor , cable alleys, cable gland i/c providing following switch gears All ACBs should have Ics=Icu=Icw for 1 sec 65kA/50kA All MCCBs shall be rating for 65kA/50kA /36kA/25kA (Ics=Icu). All MCCBs above 63A should be provided with Copper Spreader Terminals Marshalling Bay To Be Provided for BMS Operation Please consider IP42 for Indoor panel & IP 55 for out door panels if it is not specified . Approval shall be taken for each panel before fabrication. contractor to consider the termination requirement as per the cable sizes furnished in the SLD

-

-

-

... More
If any additional termination box is required the same shll be considered by contractor in the panel cost itself. The fault level of the component shall be same as the bus bar fault level indicated. The panel shall be designed to suit to the site condition. If any U shape/L shape panels required as per site requirement, contractor to consider all required dummy panel, adaptor boxes, bus bar extension, other accessories, etc. in the panel cost itself. All the cost required for BMS integration like cable,control modules,converters, connectors etc as per the attached scheme shall be included in panel cost itself. The scope shall include relay coordination study. ON / OFF / TRIP status for all the incomming breakers (ACB, MCCB, MCB, MPCB, RCBO) & meter parameter from all main panel (Listed Below) to be provided through modbus IP output (PLC) to connect to BMS through ethernet switch located within one of the panels in each electrical room. All cost towards cable, ethernet switch, BMS interface module, etc shall be covered in the panel cost itself.

-

-

-

... More
DG sync panel shall be fully comply to IEC 61439 part 1 & 2 of type tested assembly (TTA) . Any details indicated in SLD and specification is also need to be consiedered for panel cost. Any details indicated in SLD and specification is also needs to be consiedered for panel cost.

-

-

-

... More
PLC WITH SCADA SYSTEM & HMI

-

-

-

... More
PLC along with 10" HMI display unit shall be considered. The vendor / contractor has to make sure that panel is delivered along with the PLC. No additional cost will be entertained after the delivery of panels. D.G vendor has to download the upgraded software at free of cost (at least 5 times) till 100% load come on the system. The necessity of the upgrading the software and its setting will be depending on the load at which the DG sets synchronize and run. So at different loads the upgraded software has to be uploaded and will be done by the DG vendor at free of cost. The PLC shall include the following functions AMF operation with provision for manual operation PLC shall operate as per the sequence of operation that is indicated in the drawing. Necessary I/0's that are required to function PLC as per the intended operations to be generated by Vendor and approved from Project Officer. Auto Synchronization Auto Load sharing among DG sets Auto load balancing and load management with Load based Start / Stop Incoming and outgoing breaker interlocking, Neutral contactor interlocking logic & fire interlocks, provision for integration with fire system, and operating logic during fire condition. SCADA system with necessary hardware, graphical software, interface & communication cards and relays, CPU, Monitor, power supply unit cabling from PLC in the DG sync panel to SCADA CPU and monitoring system. All the incoming and outgoing breakers ON/OFF TRIP status, All the meters shall be wired and integrated into the PLC & HMI display unit. A common RS485 comm port shall be provided in the HMI for BMS connectivity. PLC shall be built in one of the vertical section in the DG Synchronizing panel. Suitable built in power supply unit along with battery back up shall be considered for PLC. 20% spare IO's shall be considered in the PLC HMI with touch screen to indicate all breaker status, engine status and including SLD to be part of DG synch. Panel. This touch screen shall have RS485 port for BMS connectivity.

-

-

-

... More
Note : Refer the SLD - TCE.12824A-EL-4001-AU-40011

-

-

-

... More
Supply, design, testing and installation of Adaptor box suitable for 2000kVA DG set connecting alternator terminals to Isolator incomer by copper flexibles / univyn cables. The adopter box shall have adequate space for mounting CT's for REF & Differential protection relays. The adaptor box shall be mounted on the alternator with necessary supports, anti-vibration connections, mounting brackets, MS stand, clamps etc. to mount the adaptor box shall be included in the price. No extra claim is entertained. Price shall be inclusive of suitable size of flexible copper bus bars / univyn cables between DG alternator terminal to the adapter box. Note : CT's for REF & Differential protection will be loose supply from the DG Vendor Panel manufacturer and installation at DG side shall be carried out by DG vendor.

3

-

-

... More
Supply ,installation testing and commissioning of CT's for REF (restricted earth flow) & Differential protection at both DG terminals side and DG incomer side in the DG Synchronizing panel. CT's shall be Class PS, 3200/5A, 10VA. Calculations for Vk and Image to be furnished and shall be co-ordinated with CT's in the Synchronizing panel. DG Synch. Panel vendor to supply to DG vendor. DG Vendor to make the space provision for installing the REF CT in neutral terminal and Differential CT's in RYB terminals.

3

-

-

... More
DG Synchronizing Panel including PLC WITH SCADA SYSTEM for auto load sharing, auto synchronizing and mimic diagram.

1

-

-

... More
AUTOMATIC FIRE DETECTION AND SUPPRESSION SYSTEM WITH Novec 1230/ FK5-1-12 GAS & Complete - For DG Synchronizing Panel

1

-

-

... More
CONTROL CABLES

-

-

-

... More
Supply , laying of 1.1KV Grade FRLS Copper armoured Control Cabling inbetween Day oil tanks, DG Sync Panel/DG power Panel, Auxillary power panel, Sensing cables from utility power panels along with its end terminations inclusive of brass double compression glands and copper lugs for complete auto & manual control and logical operations. All necessay control cabling shall be considered under this line Item required for fully auto operation of entire DG & Fuel system. Supply & end termination of following CU FRLS armoured power/ control (shielded Signal) cables with necessary double compression brass glands, CU. terminal sockets, insulation tapes, fasteners, earthing clips & connecting the clip to main earth bus with suitable bare copper wire complete accessories as required

-

-

-

... More
24C x 1 sq. mm. YWY cable

240

-

-

... More
End termination for 24C x 1 sq. mm. YWY cable

6

-

-

... More
12C x 2.5 sq. mm. YWY cable

180

-

-

... More
End termination for 12C x 2.5 sq. mm. YWY cable

12

-

-

... More
10C x 2.5 sq. mm. YWY cable

180

-

-

... More
End termination for 10C x 2.5 sq. mm. YWY cable

12

-

-

... More
6C x 2.5 sq. mm. YWY cable

180

-

-

... More
End termination for 6C x 2.5 sq. mm. YWY cable

12

-

-

... More
4C x 2.5 sq. mm. Cu. Flexible cable (Shielded Cable)

90

-

-

... More
End termination for 4C x 2.5 sq. mm. Cu. Flexible cable

6

-

-

... More
4C x 2.5 sq. mm. YWY cable

360

-

-

... More
End termination for 4C x 2.5 sq. mm. YWY cable

18

-

-

... More
3C x 2.5 sq. mm. YWY cable

180

-

-

... More
End termination for 3C x 2.5 sq. mm. YWY cable

6

-

-

... More
2C x 4 sq. mm. YWY Cable

180

-

-

... More
End termination for 2C x 4 sq. mm. YWY Cable

6

-

-

... More
2C X 2.5 Sq. mm YWY cable

90

-

-

... More
End termination for 2C X 2.5 Sq. mm YWY cable

2

-

-

... More
Supply & Installation of Drip tray for fuel pipes. The cost shall include necessary supports, necessary clamping on each fuel pipe running in the drip tray.200 x 75mm dia floor mounted MS drip tray, running along the length of fuel storage room and as header for pipes to individual DG's. 100 x 75mm dia floor mounted MS drip tray, running from main header to individual DG's in DG room.

30

-

-

... More
VENTILATION / ACOUSTIC TREATMENT

-

-

-

... More
Supply & Installation of Power Coated Factory Fabricated panel Type DG Room acoustic insulation as specified in and complete with including all MS angle supports, etc. Vendor shall submit the required calculation for thickness of insulation and consider necessary items to full fill the requirement of noise level as per CPCB norms i) Insulation ii) G.I channel framing work as specified. Pre fabricated ( including attenuators)

660

-

-

... More
Supply & Installation of Acoustically treated fresh air attenuator with louvers & angle frame work with fixing accessories, to be fixed on wall, it shall be suitable for supplying required air in CFM for DGs. Quantities are tentative and actual quantities to/be worked out by the vendor.

100

-

-

... More
Supply & Installation of Acoustically treated hot air attenuator with angle frame work & fixing accessories, to be fixed on hot air chamber wall (between DG room & hot air wall), it shall be suitable for exhausting the hot air in CFM for DGs. Quantities are tentative and actual quantities to be worked out by the vendor.Duct transformation from canvas to the hot air plenum for Above DG Sets fabricated out of 18G GI Sheet complete with access door duly painted with floor supports as per specifications.Double layer fire retardant canvas for DG Radiator exhaust suitable for DG Set to be considered .

80

-

-

... More
Supply & Installation of Acoustically treated removable Exhaust hot air louvers with angle frame work & fixing accessories, to be fixed on external wall to throw hot air from chamber, it shall be suitable for supplying required air in CFM for Above DGs. Work shall be complete with removable blind panels for DG logistics. complete system has be considered with rain water protection fins wherever required.

80

-

-

... More
Supply & Installation of Double leaf Acoustic door 100mm thick with view panel-Acoustically treated MS door with acoustic panels & angle frame- 1.8Mts (wide) and 2.4 (Height)

1

-

-

... More
Supply & Installation of Single leaf door with view panel Acoustically treated MS door with acoustic panels & angle frame-for personnel entry standard size 1.0Mts (wide) and 2.4 (Height).

4

-

-

... More
EARTHING

-

-

-

... More
GI EARTHING CONDUCTOR

-

-

-

... More
Supply , laying & termination of the following sizes of GI earth flats buried underground / laid in cable trays as per drawing & specification. All joints in the runs of the conductor shall be welded. For earth strips laid below ground, cost shall include necessary excavation, backfilling etc. including associated works Below items can be used of DG and Electrical works related erathing requirements.

-

-

-

... More
75 x 10mm GI

225

-

-

... More
75 x 6mm GI

30

-

-

... More
CU EARTHING CONDUCTOR

-

-

-

... More
Supply , laying & termination of the following sizes of CU earth flats buried underground / laid in cable trays as per drawing & specification. All joints in the runs of the conductor shall be welded. For earth strips laid below ground, cost shall include necessary excavation, backfilling etc. including associated works Below items can be used of DG and Electrical works related erathing requirements.

-

-

-

... More
60 x 10mm Cu. strip

230

-

-

... More
50 x 10mm Cu. Strip

20

-

-

... More
Supply and installation of Earth pads made out of copper bus bars installed on 1100 V Insulators including hardware and other minor civil works. Associated works.

-

-

-

... More
500 x 75 x 10mm

3

-

-

... More
500 x 50 x 10mm

3

-

-

... More
Supply and installation of Earth pads made out of GI bus bars installed on 1100 V Insulators including hardware and other minor civil works. Associated works.

-

-

-

... More
500 x 75 x 6mm

3

-

-

... More
500 x 50 x 10mm

3

-

-

... More
300 x 25 x 6mm

3

-

-

... More
FIRE SAFETY ACCESSORIES & MISCELLANEOUS

-

-

-

... More
Supply, Providing & Fixing the following other miscellaneous items:

-

-

-

... More
Supply and positioning of Electrical 1.1kV Class-A approved tested quality Rubber mats of 1.8 m length, 0.9 m wide & 5mm thick, installed in front of the power distribution boards and DBs conforming to latest BIS.

9

-

-

... More
Supply, lnstallation, testing and Commissioning of ABC Dry Chemical powder Mono-Ammonium Phosphate (MAP)-90% (stored pressure) type - 6 kg Fire Extinguisher conforming to IS:15683, with ISI marked approved fitted with required accessories including wall suspension brackets as per specification/drawings and as directed by Architect / Project Officer`s in charge .

1

-

-

... More
Supply and positioning of Mobile foam unit of 50 lts. Capacity with water inlet and foam water out let, foam maker, foam branch pipe & hoses etc. complete. Unit shall be fabricated by M.S. sheet with FRP lining inside and whole unit mounted with rubber wheels of suitable size and handle for movements. Make: Gunnebo

2

-

-

... More
Supply and fixing of Statutory Sign Boards as per Approval requirement

2

-

-

... More
Supply of Hand operated fuel transfer pump with flexible hose PVC pipe of 10M length.

2

-

-

... More
LIAISON WORKS

-

-

-

... More
Vendor should coordinate and Obtaining clearance, license and safety certificates from State pollution control board, CEIG ,CCOE (if Applicable) and other local bodies, etc if any applicable for installation and operation of the 3x 2000 kVA DG SET.

1

-

-

... More
HSD WORKS

-

-

-

... More
DIESEL STORAGE & TRANSFER - ABOVE GROUND LEVEL: Designing, Supply of storage tank, piping and pipe fittings, valves, Gaskets and supports structural, Installation, pre commissioning, painting as per code and commissioning and getting approval of storage & pumping system for Diesel unloading and transfer from diesel storage yard to plant use as per technical specification and codes and Indian standards and also as per rules and regulation stipulated by chief Controller of explosive dept and The petroleum Rules 2002 amended by 2005 Diesel Tank -TANK CAPACITY & SIZE: 20KL . The Dimesensions of 20KL Tank should be considered as per relveant IS standards ( IS 10987 )and as per stauatory requirements. Necessary drawing to be submitted for review and approval from Project Officer before procurement .

1

-

-

... More
Supply And installation of Diesel Tanks (DG Day tank : 03 Nos. / Overflow Tank : 01 No. / Intermediate tank 01 Nos.) vertical square tank of 990 Liter capacity made out of Carbon Steel to SA 515 Gr. 70 with minimum 5 mm thick plate and proper reinforcement angle and support structures, Inlet, outlet, level control, drain , overflow and spare nozzles made out of ANSI standards flanges Cl 150sorf with Sch 40 pipes and fabricated as per IS803-1976: reaffirmed 1995 Code of practice for design, fabrication, testing & installation of vertical cylindrical /Rectangular welded diesel storage day tanks and as per rules and regulation of chief Controller of explosive dept. and The petroleum Rules 2002 amended by 2005 Also Two coats of Red oxide primer with two coats of final epoxy paint as per IS colour code. Mounting structure for master day tank of height 3mtrs need to be considered in the costing.

5

-

-

... More
HSD YARD UNLOADING PUMP: Supply, Transportation, Insurance, Unloading at site, installation & commissioning of HSD transfer pump of gear pump as per below techinical speification to work on 3 Phase 415 V 50 cycles with necessary suction and discharge piping with valve cum strainer, non return valve flame proof motor, flame proof starter suitable for outdoor installation, suction and delivery outlets, companion flange nuts, bolts, gaskets etc. complete. Rate quoted shall include for starters and other motors control unit and , adequate size cable from starter to motors. and earthing inside the yard MS supports as necessary for pump installation. Diesel transfer Pumping control system having Solenoid valve control & instrumentation with level sensor, indicating and control instrument, valve and accessories etc Type :GEAR PUMPS Capacity flow :200 LPM FOR OVERLFLOW / 100 LPM FOR TRANSFER Total Head :40 MWC Minimum DELIVERY Pressure shall be 2 bar Speed RPM :1450 Shaft :EN9/SS 304 Casing :CS/CI /CF 8M GEARS :EXTERNAL /ALLOY Coupling :DIRECT Gland :Mechanical Seal Unloading pump:(1 working +1Standby) - 1 sets

1

-

-

... More
ELECTRICAL CONTROL PANEL FOR HSD TANK UNLOADING PUMP Supplying, installing, testing and commissioning of flame proof starter panel for HSD UNLOADING PUMP. This panel should be provision of BMS integration for level monitoring and pump status monitoring

1

-

-

... More
OVERFLOW PUMP & TRANSFER PUMP upply, Transportation, Insurance, Unloading at site, installation & commissioning of over flow transfer pump of gear pump as per below techinical speification to work on 3 Phase 415 V 50 cycles with necessary suction and discharge piping with valve cum strainer, non return valve flame proof motor, flame proof starter suitable for outdoor installation, suction and delivery outlets, companion flange nuts, bolts, gaskets etc. complete. Rate quoted shall include for starters and other motors control unit and , adequate size cable from starter to motors. and earthing inside the yard MS supports as necessary for pump installation. Diesel transfer Pumping control system having Solenoid valve control & instrumentation with level sensor, indicating and control instrument, valve and accessories etc Type :GEAR PUMPS Capacity flow :100 LPM Total Head :40 MWC Minimum DELIVERY Pressure shall be 2 bar Speed RPM :1450 Shaft :EN9/SS 304 Casing :CS/CI /CF 8M GEARS :EXTERNAL /ALLOY Coupling :DIRECT Gland :Mechanical Seal (1 working +1Standby) - 1 sets

2

-

-

... More
ELECTRICAL CONTROL PANEL FOR OVERFLOW PUMP & TRANSFER PUMP Supplying, installing, testing and commissioning of starter panel for OVERFLOW PUMP & TRANSFER PUMP pumps. This panel should be provision of BMS integration for level monitoring and pump status monitoring

1

-

-

... More
DIESEL distribution piping carried out of CS class Schedule 40 ASTM Gr106B Seam less pipe with minimum wall thickness of 3mm for pipes seamless fittings as per technical specifications of sizes and quantities listed below: The works shall include The standard pipe fitting like Equal Tee, unequal tee Reducer, Elbow, Bend etc all inclusive and all necessary supports and banding as per specifications. All above ground piping are to be painted by corrosive resistance epoxy paints . The scaffolding and installation of secondary supports are included All under ground piping's are duly cleaned , one coat of epoxy primer and covered with PIPE KOTE bituminous wrapping . If any under ground piping the scope includes the cost of excavation and backfilling work .ALL JOINTS ARE TO BE WELDED For both indoor and outdoor Over head and under ground pipes

-

-

-

... More
50 mm NB

230

-

-

... More
40 mm NB

45

-

-

... More
25 mm NB

45

-

-

... More
SITC of CS Pipes with neccesory fittings Under Ground

-

-

-

... More
50 mm NB

230

-

-

... More
MISCELLANEOUS CAST STEEL BALL VALVES with flanged fasteners, support arrangement as per specifications of sizes and quantities as detailed below: The rate quoted shall include for providing flange with necessary gaskets, nuts, bolts, washers, etc

-

-

-

... More
50 mm NB

16

-

-

... More
40 mm NB

6

-

-

... More
25 mm NB

10

-

-

... More
3 WAY CAST STEEL VALVES with Stainless Steel CF8 internals,Class150, flanged end & fasteners, support arrangement as per specifications of sizes and quantities as detailed below

-

-

-

... More
50 mm NB

3

-

-

... More
Supplying, installing, testing and commissioning flame proof Solenoid valve suitable for MS pipes

-

-

-

... More
25 mm dia. (Flanged ends)

4

-

-

... More
CAST STEEL STRAINER with Stainless Steel Internals, Y Type, Mesh 40 with CI 150 ANSI , made out of hot tipped Galvanized Flanged connection.

-

-

-

... More
50mm NB

6

-

-

... More
Glycerin filled Pressure gauge 6" dial with 20NB isolation valve

10

-

-

... More
FLEXIBLE UNLOADING HOSE :Supply of Neoprene hose as per BS 1435/1968 suitable for diesel oil including fitting of one end flanged and other end with suitable coupler. (Decanting Hose) a) 80 mm dia. X3 Mtrs long

2

-

-

... More
Supplying, installing and commissioning Portable Fire extinguishers of following type & capacity. MECHANICAL FOAM TYPE - 9 LTRS Mechanical foam type fire extinguisher of 9 Ltrs. Capacity, with initial filling in brand new cylinder with powder coated finish fitted with Gun metal union, discharge hose, complete, confirming to IS code.

3

-

-

... More
SAND FILLED BUCKETS - 3nos With Holding Stand MS structure made out of 40 mm medium class MS pip (class B), 25 x 25 x 3 mm angle iron from work and 14 SWG GI sheet structure shall be grouted in 1:2:4 CC foundation Including 8 nos 9 lit (24 SWG MS sheet) each fire fighting buckets including providing buckets with two coats of anticorrosive paints

2

-

-

... More
Supply, fabrication & fixing pipe supports in M.S angle iron/plates, pipes, etc., as per dwg., instruction at site Rate quoted shall include for supply & providing necessary welding, cutting,U clamps, bolts, nuts, washers as per specification.

2500

-

-

... More
Supply, fabrication &installation of M.S FENCING in M.S angle / channel/Wire Mesh for height of 2.5mtrs Height instruction at site in charge Rate quoted shall include for supply & providing necessary welding, cutting, clamps, bolts, nuts, washers civil works to grout the fencing support members as per specification and as per dwgto meet the norms & as per CCOE and other statutory rules and regulations

1

-

-

... More
Supply, installation, testing & Commissioning of 100mm dia 13mm thick 2500mm long earth electrode as per IS 3043 complete with all works like excavation, refilling with soil treating media like charcoal, salt, Bentanite powder, watering the system etc. equipped with heavy duty top cover made out of Cast iron or RCC slab meant for Heavy duty 75 ton truck loads. Rate shall be inclusive of testing of earth electrode to acheive combined earth resistance less than 2 Ohms.

4

-

-

... More
Electro magnetic Digital Flow Meter to suit oil flow measurement with internal contact, parts made out of stainless steel and compatible with BMS control of the system Its measuring chamber is fireproof of oscillant disc and it allows to transfer any type of hydrocarbon liquids Flow: 10-90 l/min, Accuracy: ±1 %, Partial indicator of 3 digits and totalizer of 6 digits Maximum operation pressure: 5 bar & Resistance pressure: 15 bar Ambient temperature: -10 ºC / +60 ºC ; ATEX IIG Category Size :40mm NB Flow 4m3/hr

2

-

-

... More
TRANSFER & LEVEL CONTROL SYSTEM DIESEL TRANSFER PUMPING CONTROL SYSTEM - SOLENOID VALVE Control for all 6 nos Day tank and main storage tanks For the below said control, instrumentation with level sensor, indicating and control instrument, valve and accessories are to installed with necessary electrical cabling work up to HSD storage pump house to start/stop the supply pump. For the below said control, instrumentation with level sensor, pressure switch, timer operated indicating and control instrument, isolation and control valve and accessories are to installed with necessary electrical cabling & control cabling work up to HSD storage pump house to start/stop the supply pump. 1) When DAY TANK level reaches low incoming valve at 990 Ltrs tank GET OPENED valve works recycling to tank will open and pumps star. 2) When DAY TANK level reaches high incoming valve at 990 Ltrs tank GET CLOSED valve works recycling to tank will open and pumps stops.

1

-

-

... More
Charges for liaison work to getting approval from chief controller of Explosive (CCOE) For installation and operation of the storage and transfer system

1

-

-

... More
300 dia NP2 class hume. (Excavation & refilling cost need to be considered.)

80

-

-

... More
Electrostatic Earthing system for tanker grounding.

-

-

-

... More
Supply and installation of earthing integrity monitoring system for tanker unloading with all necessary indications , interlockings , alarms , switches and cable entry points. The System shall be in flame proof enclosure with CCOE certification.

1

-

-

... More
Heavy duty chrome plated earthing clamps

2

-

-

... More
Heavy duty flame proof earthing cable (10 Sq.mm) , 5 Mtrs in length

2

-

-

... More
HVAC WORKS Design, Engineering, Supply, Inspection, testing, erection and commissioning of following items including water and air balancing.

-

-

-

... More
CHILLERS -Design, Supply, delivery, hoisting, including the customs clearance, freight up to site, Insurance, port handling charges, other local duties, loading, transportation, receving at site, unloading, positioning the chiller as per approved shop drawing, installation including supplying & installing all necessary accessories as required for complete and satisfactory operation, testing & commissioning for the following items as shown on the equipment data and drawing for complete and satisfactory operation. Specification to be complied by the vendor to met the performance of chiller as per tender conditions. First chiller shall be factory tested at design conditions at 100%, 75%, 50% and 25% load. (Charges for arranging inspection of chillers for 5 persons, at Manufacturer’s point for witnessing testing the chiller ( 1no. chiller ) at minimum 4 test points .. Clearly indicate the facilities available at manufacturer’s point for testing and also confirm wehther test bed is AHRI approved) All necessary hardwares / software's to integrate the chiller panel to BAS system shall be provided free of cost by chiller manufacturer / supplier. Control panel should be with open protocol like Modbus RTU/ Bacnet/ Lon work for integrating with BAS. Chiller is accepted only based on 100% loading and its performance shall be tested at site against approved data sheet. Any fall back on the performance to be corrected and rechecked and then chiller will be accepted.

-

-

-

... More
WATER COOLED CHILLERS -Supply, Installations, testing, erection and commissioning of WATER COOLED CENTRIFUGAL CHILLERS with BMS compatible VFD (Unit mounted factory calibrated. VFD shall be with active harmonic filter with THD not exceeding 5%.VFD shall be liquid cooled only, water/refrigerant cooled as per OEM standard.), IE4 motor, water cooled condenser, insulated chiller, flow switch at chiller and condenser, spring vibration isolators, integral refrigerant piping and wiring, grooved couplings at chilled & condenser water inlets & outlets, marine water box at condenser with hinges, accessories as required and called for, automatic and safety controls mounted in central console panel and all mounted on a steel frame etc. Motor shall be suitable for operating on 415±10% 50 cycles. 3 phase AC supply and soft starter. Refrigerant used shall be Ozone friendly HFC R134a/ R 1233ZD as per specifications. Chiller for air conditioning system shall be selected on the design basis as given below condition. The chiller Microprocessor shall be suitable for BMS integration and provided with suitable protocal. Chillers capacity of each chilling unit will be as follows: Rate shall inclusive of factory witness test as specified in the technical specification. Chiller: Capacity -475TR Chilled Water IN - 54°F . Chilled Water Out - 44°F Chilled Water Flow - 1140 USGPM or as required Fouling factor - 0.0001 FPS, Condenser: Condenser Water IN - 89.06 °F, Condenser Water OUT - 97.16.2 °F Condenser Water Flow - 1662 USGPM or as required Fouling factor - 0.00025 FPS Maximum Power Consumed at above conditions : Not more than 0.63 kW/ TR Minimum IPLV: 0.37 Min COP at AHRI conditions : 6.5 or above

3

-

-

... More
AIR COOLED CHILLER - Design, Supply, installation, testing and commissioning of Air COOLED SCREW CHILLER . - multiple screw compressors, energy efficient IE4 motor, Air cooled condenser, flow switch at chiller , spring vibration isolators, integral refrigerant piping and wiring, grooved couplings at chilled water inlets & outlets, accessories as required and called for, automatic and safety controls mounted in central console panel and all mounted on a steel frame etc. Motor shall be suitable for operating on 415±10% 50 cycles. 3 phase AC supply. Refrigerant used shall be Ozone friendly HFC R134a/ R 1233ZD as per specifications. Chiller for air conditioning system shall be selected on the design basis as given below condition. The chiller Microprocessor shall be suitable for BMS integration and provided with suitable protocal. Chillers capacity of each chilling unit will be as follows: Rate shall inclusive of factory witness test as specified in the technical specification. Chiller Capacity : 150 TR at Design Condition ( +/- 2% on capacity) Chiller Performance: 1.3 kW/TR FL and 1.1 kW/TR IPLV (max) at Design condition Chiller Side: Chiller Water in : 54 Deg F & Chiller Water out: 44 Deg F Ambient air temp 104 deg F Water Flow rate : 360 GPM Fouling factor : 0.0001 hr.sqft.degF/BTU Min COP at AHRI condition: 3.2 or above

2

-

-

... More
COOLING TOWER

-

-

-

... More
Design, Supply, installation, testing and commissioning of COOLING TOWER with BMS compatible VFD, Cross Flow or Counterflow, Induced Draft, Vertical Discharge Type, Twin Cell, FRP Cooling Tower complete with multiple motor, fan, film type Fill, other complete accessories as described in the technical specifications. It shall be designed with high efficiency drift eliminator. Vibration Isolators of spring open type designed to minimize any vibration from transmitting to other structures to be included in the scope of supply. Motors shall be suitable for 415 + 10%volt, 50 cycles 3phase power supply and IE4 efficiency type. The power Isolators (lockable type) at cooling tower enclosed in weather proof panel and required length of power cable from the starter panel to the equipment shall also be included. Cooling Tower for air conditioning system shall be selected on the basis of monsoon ambient condition. The heat rejection capacity of the cooling tower must be 1.25 times greater than the chiller capacity. The tower shall be CTI certified. Chiller Capacity : 475TR- (Cooling tower Capacity shall be in HRT) Water Flow Rate : 1662 USGPM Water Temp In & Out : 97.16 degF & 89.06 degF, Design wet bulb : 82.04 degF Approach : 7.02 Deg F

3

-

-

... More
CENTRIFUGAL VERTICAL INLINE PUMPS

-

-

-

... More
PRIMARY PUMPS FOR WATER COOLED CHILLER- Supply, erection, testing and commissioning of Single stage centrifugal coupled type INLINE pumpset with axial suction port and discharge port (with Bacnet MS/TP communication protocol), bronze impeller & mechanical seal. The noise level shall be limited to 70 dBA at a distance of 1.5 m, Minimum pump efficieicy should not be less than 85%, Motor efficieny not less than 90% (IE-4). Suitable HP,motor shall be TEFC squirrel cage type motors with IP55 protection. The Coupling shall be rigid spacer type of high tensile aluminum alloy. Couplings shall be split to allow removal from pump and motor shafts, leaving space between the shafts sufficient to replace all mechanical seal components without disturbing the pump or motor.The duty point of the pump shall be defined in the pump curve. (Insulation for chilled water pumps to be 32mm nitrile rubber of minimum density 36kg/m3, thermal conductivity of 0.032W/mK at 25 Deg C, covered with 500 GSM two layer vapour barrier and covered with 26 G Aluminium cladding). Pump design parameter / motor rating furnished in the BOQ is of indicative in nature. If the actual parameter required to meet the proposed HVAC system, then the same shall be provided by HVAC Contractor based on the final pump/motor selection without any cost implication to the Owner. Constant flow primary pump: 1140 GPM to be delivered @ 15M head

3

-

-

... More
SECONDARY PUMPS FOR WATER COOLED CHILLER: Supply, erection, testing and commissioning of Single stage centrifugal coupled type INLINE pumpset with axial suction port and discharge port with integrated variable speed drive motor(pump mounted) (with Bacnet MS/TP communication protocol), bronze impeller & mechanical seal. The noise level shall be limited to 70 dBA at a distance of 1.5 m, Minimum pump efficieicy should not be less than 85%, Motor efficieny not less than 90% (IE-4). Suitable HP,motor shall be TEFC squirrel cage type motors with IP55 protection. VFD - The variable frequency drive(s) shall be pulse width modulation (PWM) type, microprocessor controlled design.VFD shall be capable of operating in voltage ranges of 380 to 415 V +/- 10% AC, three phase; at frequencies of 48 to 63 Hz. VFD shall be factory fitted and unit mounted. The control should be a low harmonic control with a built-in DC link reactor equivalent in performance to a 5% AC line reactor.VFDs shall comply with IEC 61800-3 & have THD less than 5%. Active / passive filters must be use toachieve desired THD levels which will be in scope of Drive authorized supplier of OEM as per list of approved make. IEEE - 519 - 2014 standard is to be followed for harmonic control. VFDs shall be motor mounted and IP 54 rated.The Coupling shall be rigid spacer type of high tensile aluminum alloy. Couplings shall be split to allow removal from pump and motor shafts, leaving space between the shafts sufficient to replace all mechanical seal components without disturbing the pump or motor.The duty point of the pump shall be defined in the pump curve. The pump selected for variable speed drive shall be capable of performing satisfactorily over a wide range of speed, allowing a speed variation from 30 % to 100 %. The pump matrix also to be filled up for all vendors.(Insulation for chilled water pumps to be 32mm nitrile rubber of minimum density 36kg/m3, thermal conductivity of 0.032W/mK at 25 Deg C, covered with 500 GSM two layer vapour barrier and covered with 26 G Aluminium cladding). Pump design parameter / motor rating furnished in the BOQ is of indicative in nature. If the actual parameter required to meet the proposed HVAC system, then the same shall be provided by HVAC Contractor based on the final pump/motor selection without any cost implication to the Owner. Variable flow Secondary pump: 1140 GPM to be delivered @ 25M head

3

-

-

... More
CONDENSER PUMPS with BMS compatible VFD - Supply, erection, testing and commissioning of Single stage centrifugal coupled type INLINE pumpset with axial suction port and discharge port (with Bacnet MS/TP communication protocol), bronze impeller & mechanical seal. The noise level shall be limited to 70 dBA at a distance of 1.5 m, Minimum pump efficieicy should not be less than 85%, Motor efficieny not less than 90% (IE-4). Suitable HP,motor shall be TEFC squirrel cage type motors with IP55 protection. The Coupling shall be rigid spacer type of high tensile aluminum alloy. Couplings shall be split to allow removal from pump and motor shafts, leaving space between the shafts sufficient to replace all mechanical seal components without disturbing the pump or motor.The duty point of the pump shall be defined in the pump curve. (Insulation for chilled water pumps to be 32mm nitrile rubber of minimum density 36kg/m3, thermal conductivity of 0.032W/mK at 25 Deg C, covered with 500 GSM two layer vapour barrier and covered with 26 G Aluminium cladding). .VFDs shall comply with IEC 61800-3 & have THD less than 5%. Active / passive filters must be use toachieve desired THD levels which will be in scope of Drive authorized supplier of OEM as per list of approved make. IEEE - 519 - 2014 standard is to be followed for harmonic control. Pump design parameter / motor rating furnished in the BOQ is of indicative in nature. If the actual parameter required to meet the proposed HVAC system, then the same shall be provided by HVAC Contractor based on the final pump/motor selection without any cost implication to the Owner. Condenser flow pump: 1662 GPM to be delivered @ 25 M head

3

-

-

... More
Design, Supply, installation, testing and commissioning of water cooled chilled water Pump Starter Panel cum Logic controller panel with all necessary power & control circuit breakers, contactors, SPPR, auto/manual selector switches, earthing and internal power & control cabling, terminations with necessary lugs and glands, etc. , Microprocessor based logic controller, integrated Software capable to control frequency based on the inputs from sensors, 4 Nos of differential pressure sensor & transmitters, power cable from panel to pump, ON/OFF push button, communication cable, Communication card (BACnet protocol) to transfer the entire data available on unit mounted VFD (3 in Secondary pumps/ 3 in condensor pumps) to the third party BMS System.

1

-

-

... More
PRIMARY PUMPS - Supply, erection, testing and commissioning of Single stage centrifugal coupled type INLINE pumpset with axial suction port and discharge port (with Bacnet MS/TP communication protocol), bronze impeller & mechanical seal. The noise level shall be limited to 70 dBA at a distance of 1.5 m, Minimum pump efficieicy should not be less than 85%, Motor efficieny not less than 90% (IE-4). Suitable HP,motor shall be TEFC squirrel cage type motors with IP55 protection. The Coupling shall be rigid spacer type of high tensile aluminum alloy. Couplings shall be split to allow removal from pump and motor shafts, leaving space between the shafts sufficient to replace all mechanical seal components without disturbing the pump or motor.The duty point of the pump shall be defined in the pump curve. (Insulation for chilled water pumps to be 32mm nitrile rubber of minimum density 36kg/m3, thermal conductivity of 0.032W/mK at 25 Deg C, covered with 500 GSM two layer vapour barrier and covered with 26 G Aluminium cladding). Pump design parameter / motor rating furnished in the BOQ is of indicative in nature. If the actual parameter required to meet the proposed HVAC system, then the same shall be provided by HVAC Contractor based on the final pump/motor selection without any cost implication to the Owner. Constant flow primary pump: 360 GPM to be delivered @ 15M head

2

-

-

... More
SECONDARY PUMPS: Supply, erection, testing and commissioning of Single stage centrifugal coupled type INLINE pumpset with axial suction port and discharge port with integrated variable speed drive motor(pump mounted) (with Bacnet MS/TP communication protocol), bronze impeller & mechanical seal. The noise level shall be limited to 70 dBA at a distance of 1.5 m, Minimum pump efficieicy should not be less than 85%, Motor efficieny not less than 90% (IE-3). Suitable HP,motor shall be TEFC squirrel cage type motors with IP55 protection. VFD - The variable frequency drive(s) shall be pulse width modulation (PWM) type, microprocessor controlled design.VFD shall be capable of operating in voltage ranges of 380 to 415 V +/- 10% AC, three phase; at frequencies of 48 to 63 Hz. VFD shall be factory fitted and unit mounted. The control should be a low harmonic control with a built-in DC link reactor equivalent in performance to a 5% AC line reactor. VFDs shall be motor mounted and IP 66 rated .VFDs shall comply with IEC 61800-3 & have THD less than 5%. Active / passive filters must be use toachieve desired THD levels which will be in scope of Drive authorized supplier of OEM as per list of approved make. IEEE - 519 - 2014 standard is to be followed for harmonic control..The Coupling shall be rigid spacer type of high tensile aluminum alloy. Couplings shall be split to allow removal from pump and motor shafts, leaving space between the shafts sufficient to replace all mechanical seal components without disturbing the pump or motor.The duty point of the pump shall be defined in the pump curve. The pump selected for variable speed drive shall be capable of performing satisfactorily over a wide range of speed, allowing a speed variation from 30 % to 100 %. The pump matrix also to be filled up for all vendors.(Insulation for chilled water pumps to be 32mm nitrile rubber of minimum density 36kg/m3, thermal conductivity of 0.032W/mK at 25 Deg C, covered with 500 GSM two layer vapour barrier and covered with 26 G Aluminium cladding). Pump design parameter / motor rating furnished in the BOQ is of indicative in nature. If the actual parameter required to meet the proposed HVAC system, then the same shall be provided by HVAC Contractor based on the final pump/motor selection without any cost implication to the Owner. Variable flow Secondary pump: 360 GPM to be delivered @ 25M head

2

-

-

... More
Design, Supply, installation, testing and commissioning of air cooled chilled water Pump Starter Panel cum Logic controller panel with all necessary power & control circuit breakers, contactors, SPPR, auto/manual selector switches, earthing and internal power & control cabling, terminations with necessary lugs and glands, etc. , Microprocessor based logic controller, integrated Software capable to control frequency based on the inputs from sensors, 4 Nos of differential pressure sensor & transmitters, power cable from panel to pump, ON/OFF push button, communication cable, Communication card (BACnet protocol) to transfer the entire data available on unit mounted VFD (2 in Secondary pumps) to the third party BMS System.

1

-

-

... More
AIR HANDLING UNITS:

-

-

-

... More
Supply, installation testing & commissioning EUROVENT CERTIFIED Horizontal / vertical floor mount Airhandling units having following specifications. Frame Structure consisting of 45mm Extruded Aluminium Thermal break profile Panel: 45mm +/- 2mm thick double skin sandwich panels with Puff insulation of density 48 kg/cum , The sheet thickness shall be minimum 0.8 mm for the outer skin and 0.8 mm thickness for the inner skin of GI . Filtration Section shall be provided with 2 stage washable type of 'MERV8 ' first stage and 'MERV13' final stage. Coil Section: Chilled water coil Minimum 6 row deep constructed with Aluminium fins of minimum 0.11mm thickness and copper tubes of minimum 29Guage thickness. Copper tube shall be 9.6mm or 12.5mm diameter. The coil face area shall not exceed 2.5m/sec. Coil shal be provided with copper header. Inbuilt UV Lamp to be considered upstream or downstream of the coil based on OEM recommendation with necessary interlock with the AHU whenver the AHU is shutoff, UV lamp shall be off and vice versa. Drain Pan: Condensate drain pan shall be fabricated from 20 G SS 304 powder coated, insulated with 19 mm thick closed cell elastomeric insulation. Fan Section: Direct drive backward curved EC fan ( Electronically commutated ) with permanent magnet brushless DC motor for stepless variation of speed of fan based on temperature sensor inputs. The fan section shall be provided with limt switch for safety to shut off fan during Opening of access door. AHU mounted graphical display with starter Panel with Auto /Manual switch and incomer power terminal. all internal cablings between panel and motor/ door interlocks / marine lamp etc should be considered Instrumentation Kit to be provided to give out the following option 1. Supply air temperature 2. Return air temperature 3. Chilled water in temperature 4. Chilled water out temperatue 5. DP switch across filter for fitler clog Controller module with RS 485 port compatible with BMS, on board protocol with touch screen to display following 1. EC fan operation status 2. Chilled water valve operation status 3. AHU Airflow ( CFM) 4. AHU power consumption 5. Chilled water in/out Temp 6. Common Alarm Controller shall also have fire trip alarm to shut AHU incase of signal from fire panel

-

-

-

... More
5.0 TR (3000 CFM) ESP 20 MM

7

-

-

... More
7.0 TR (4200 CFM) ESP 20 MM

11

-

-

... More
10.0 TR (6000 CFM) ESP 25 MM

21

-

-

... More
12.0 TR (7200 CFM) ESP 25 MM

17

-

-

... More
14.0 TR (8400 CFM) ESP 25 MM

2

-

-

... More
16.0 TR (9600 CFM) ESP 25 MM

5

-

-

... More
18.0 TR (10800 CFM) ESP 25 MM

4

-

-

... More
22.0 TR (13200 CFM) ESP 30 MM

2

-

-

... More
24.0 TR (14400 CFM) ESP 30 MM

1

-

-

... More
Supply, installation testing & commissioning EUROVENT CERTIFIED Ceiling Suspended Airhandling units having following specifications. Frame Structure consisting of 45mm Extruded Aluminium Thermal break profile Panel: 45mm +/- 2mm thick double skin sandwich panels with Puff insulation of density 48 kg/cum , The sheet thickness shall be minimum 0.8 mm for the outer skin and 0.8 mm thickness for the inner skin of GI . Filtration Section shall be provided with 2 stage washable type of 'MERV8 ' first stage and 'MERV13' final stage. Coil Section: Chilled water coil Minimum 6 row deep constructed with Aluminium fins of minimum 0.11mm thickness and copper tubes of minimum 29Guage thickness. Copper tube shall be 9.6mm or 12.5mm diameter. The coil face area shall not exceed 2.5m/sec. Coil shal be provided with copper header. Inbuilt UV Lamp to be considered upstream or downstream of the coil based on OEM recommendation with necessary interlock with the AHU whenver the AHU is shutoff, UV lamp shall be off and vice versa. Drain Pan: Condensate drain pan shall be fabricated from 20 G SS 304 powder coated, insulated with 19 mm thick closed cell elastomeric insulation. Fan Section: Direct drive backward curved EC fan ( Electronically commutated ) EBM or Zeihl Abegg make with permanent magnet brushless DC motor for stepless variation of speed of fan based on temperature sensor inputs. The fan section shall be provided with limt switch for safety to shut off fan during Opening of access door. starter Panel with Auto /Manual switch and incomer power terminal. all internal cablings between panel and motor/ door interlocks / marine lamp etc should be considered Instrumentation Kit to be provided to give out the following option 1. Supply air temperature 2. Return air temperature 3. Chilled water in temperature 4. Chilled water out temperatue 5. DP switch across filter for fitler clog Controller module with RS 485 port compatible with BMS, on board protocol with touch screen to display following. Control module shall be located in a sperate control panel located on the nearest wall or at the location as defined by client /PMC 1. EC fan operation status 2. Chilled water valve operation status 3. AHU Airflow ( CFM) 4. AHU power consumption 5. Chilled water in/out Temp 6. Common Alarm Controller shall also have fire trip alarm to shut AHU incase of signal from fire panel Unit height should not exceed 750 mm, accordinlgy CSU dimension and fan selection to be considered.

-

-

-

... More
4.0 TR (2400 CFM) ESP 15 MM

18

-

-

... More
6.0 TR (3000 CFM) ESP 15 MM

1

-

-

... More
8.0 TR (4000 CFM) ESP 15 MM

1

-

-

... More
11.0 TR (6000 CFM) ESP 20 MM

4

-

-

... More
CHILLED WATER CASSETTES along with Chilled Water Valve package consisting of Ball valve with and without strainer and PIBCV self dynamic balancing cum control valve for CHW flow control and all accessories required shall be part of scope. MS to Copper connectors required to connect from the main CHW MS pipeline before connecting to unit. Dgital wireless remote shall be part of scope. Factory assembled valve station of Linear Characteristic PICV as per required dia with PT port & diaphragm, Test Point, Filter Ball Valve & Bypass Valve arrangement with Insulation Kit & Modulating Electromotive Actuator (Non Spring Return) with BMS Compatible & with Flexible Hoses Valve staton shall be located in a drip tray made of 22 G GI sheet insulated from the bottom of the sheet, tray shall be provided with a height of 50 mm minum and length/width shall be able to cover the entire valve station. UNIT shall be wth inbuilt BMS compatibility with Modbus RS485 protocol output. Unit shall swicth on/off based on remote on/off command & status ( EUROVENT CERTIFIED)

-

-

-

... More
0.8 TR ( Four way cassette)

1

-

-

... More
1.0 TR ( Four way cassette)

5

-

-

... More
1.5 TR ( Four way cassette)

6

-

-

... More
2.0 TR ( Four way cassette)

5

-

-

... More
2.5 TR ( Four way cassette)

3

-

-

... More
3.0 TR ( Four way cassette)

6

-

-

... More
4.0 TR ( Four way cassette)

2

-

-

... More
1.0TR (One way cassette)

1

-

-

... More
1.5TR (One way cassette)

1

-

-

... More
2.0TR (One way cassette)

14

-

-

... More
Supply, Installation, testing & commissioning of fan coil units as specified and shown in the drawing, data sheets etc. consisting of: i) Supply & Installation of 2-way motorized PIBC valve with actuator, 2 Nos ball valves, one of them with strainer ii) Supply & Installation of compatible room thermostat iii) Supply & Installation of Power wiring from the 5A switch socket within 2 meter along with a 5A plug top iv) Supply & Installation of Halogen Free control wiring (10C, 1.5 sq.mm) between the unit and thermostat including 25mm dia pvc conduit v) Supply & Installation of Supporting frame and suspenders vi) Supply & Installation of Earthing of motor and unit. vii) Installation of pipe (CHWS & CHWR) & 19mm thk Class 0 nitrile rubber insulation from main riser / header to the unit viii) Extended drain pan SS316, double skin with insulation. ix) Canvas connection (Fire retardant) at FCU outlet. x) 4-speed DC motor with direct drive

-

-

-

... More
1.0 TR Fan Coil Units covering all the above items High static

1

-

-

... More
1.5 TR Fan Coil Units covering all the above items High static

1

-

-

... More
2.0 TR Fan Coil Units covering all the above items High static

1

-

-

... More
2.5 TR Fan Coil Units covering all the above items High Static

1

-

-

... More
3.0 TR Fan Coil Units covering all the above items High Static

2

-

-

... More
4.0 TR Fan Coil Units covering all the above items High Static

2

-

-

... More
Supply, installation, testing & commissioning of Chilled water type Hi-wall unit with Fan, Motor having Hi-medium-Low speed,, CHW cooling Coil of sutable RD ,Filter , controls, decorative panel & power wiring from nearest power socket to indoor unit.The units should be suitable for 10 ºF Δ T ( CHW inlet temperature should be 44 ºF and outlet should be 54 ºF, Should be inclusive with valve Kit (1 Ball valve with y strainer in the supply side & 1 Ball valve with 2 Way Control Valve in the Return Line) & should include flexible CU hose to connect the chilled water pipe line to the valve Kit.

-

-

-

... More
0.8 TR Hi wall unit

1

-

-

... More
1 TR Hi wall unit

1

-

-

... More
1.5 TR Hi wall unit

1

-

-

... More
1.8 TR Hi wall unit

1

-

-

... More
2.0 TR Hi wall unit

1

-

-

... More
INSULATED CHILLED WATER PIPE AND VALVES FOR CHILLED WATER PIPES

-

-

-

... More
Supply, erection, testing and commissioning of pre-insulated pipes for Chilled water circulation pipes. Pipes will be of Mild Steel (pipe wall thickness as indicated below) and insulation material shall be PUF as per the specification. The pre-insulated pipe shall be covered with 24 Gauge aluminium spiral casing. MS 'C' class pipes as per IS 1239 / IS 3589 with specified wall thickness cut to required lengths and installed with all Accessories Class of Pipe:- Sizes up to 150 mm shall confirm to IS 1239 Sizes above 150 mm shall confirm to IS 3589 MS 'C' class pipes up to 150 mm dia Pipe dia – mm Thickness - upto 200 mm dia - 5 mm thickness 250 mm to 350 mm dia - 6 mm thickness. above 350 mm dia - 8 mm thickness insulation details Up to 32 mm : 30mm thick 49 mm to 100 mm : 40mm thick 125mm up to 300 mm : 50 mm thick 350 & above : 75 mm thick All GI / MS supports along with accessories for a maximum height of 2-3 mtr either from the ceiling slab or floor slab shall be considered in this item.

-

-

-

... More
300 mm dia

130

-

-

... More
250 mm dia

80

-

-

... More
200 mm dia

252

-

-

... More
150 mm dia

120

-

-

... More
125 mm dia

497

-

-

... More
100 mm dia

435

-

-

... More
80 mm dia

396

-

-

... More
65 mm dia

428

-

-

... More
50 mm dia

847

-

-

... More
40 mm dia

881

-

-

... More
32 mm dia

1093

-

-

... More
25 mm dia

1477

-

-

... More
Supply and erection of Pre-insulated Butterfly valves (with RPUF material similar to CHW pipe insulation specifications) complete with pre-insulated end flanges / matching flanges, additional supports, fixing accessories, etc. The valve shall be gear operated for 200NB and above.

-

-

-

... More
300 mm dia

3

-

-

... More
250 mm dia

10

-

-

... More
200 mm dia

16

-

-

... More
150 mm dia

1

-

-

... More
125 mm dia

18

-

-

... More
100 mm dia

8

-

-

... More
80 mm dia

14

-

-

... More
65 mm dia

22

-

-

... More
50 mm dia

175

-

-

... More
40 mm dia

139

-

-

... More
32 mm dia

89

-

-

... More
25 mm dia

168

-

-

... More
Supply and erection of Pre-insulated Dual plate Check valves (with RPUF material similar to CHW pipe insulation specifications) complete with pre-insulated end flanges/matching flanges, additional supports, fixing accessories, etc.

-

-

-

... More
300 mm dia

1

-

-

... More
250 mm dia

1

-

-

... More
200 mm dia

6

-

-

... More
150 mm dia

1

-

-

... More
125 mm dia

4

-

-

... More
100 mm dia

1

-

-

... More
Design, Supply, installation, testing and commissioning of Pre-Insulated Balancing Valve (with RPUF material similar to CHW pipe insulation specifications) shall be of factory calibrated direct, acting, automatic pressure compensation type. Each valve shall limit flow rates to within ± 5 % accuracy, regardless of the system pressure fluctuations. Rate shall inclusive of additional supports, fixing accessories, thermal insulation, etc.

-

-

-

... More
300 mm dia

1

-

-

... More
250 mm dia

1

-

-

... More
200 mm dia

3

-

-

... More
150 mm dia

1

-

-

... More
125 mm dia

2

-

-

... More
100 mm dia

1

-

-

... More
80 mm dia

1

-

-

... More
Supply and erection of Pre-insulated ‘Y’ type strainer (with RPUF material similar to CHW pipe insulation specifications) with removable stainless steel screen with 3mm perforation and permanent magnet, drain piping. Rate shall inclusive of pre-insulated end flanges/matching flanges, additional supports, fixing accessories, etc.

-

-

-

... More
300 mm dia

1

-

-

... More
250 mm dia

1

-

-

... More
200 mm dia

6

-

-

... More
150 mm dia

2

-

-

... More
125 mm dia

4

-

-

... More
100 mm dia

1

-

-

... More
80 mm dia

1

-

-

... More
65 mm dia

5

-

-

... More
50 mm dia

32

-

-

... More
40 mm dia

35

-

-

... More
32 mm dia

35

-

-

... More
Design, Supply, installation, testing and commissioning of Pre-insulated Two way motorized Valves (ON / OFF Type) provided with spring return function in chilled water lines at chillers and condenser water line at cooling towers. The BMS compatible actuator of the motorized valve (with RPUF material similar to CHW pipe insulation specifications) shall have required torque, the actuator with 220 V / 24 V transformer duly encased and wired. The motorized valve & actuator shall be provided with necessary communication cables, hardware, converter, pre-insulated end flanges/matching flanges, weather proof construction, etc

-

-

-

... More
250 mm dia

1

-

-

... More
200 mm dia

3

-

-

... More
150 mm dia

1

-

-

... More
125 mm dia

2

-

-

... More
100 mm dia

1

-

-

... More
Design, Supply, Installation, testing and commissioning of Pre-insulated Flow Control Valve - Pressure independent type with Dynamic Balancing Cum 2 Way modulating valves (with RPUF material similar to CHW pipe insulation specifications) for AHUs with actuator in a single Unit of Valve provided with spring return function. The valve shall be suitable for standalone operation. Valve shall be of PN16 Rating. The BMS compatible actuator shall be supplied by the valve manufacturer and capable of accepting 2-10VDC / 4- 20 mA electric signal and shall provide similar transduced feedback output signal to control system. The minimum close off Pressure of actuator must be 1.5 times shut off head of pump as per specifications. Rate shall be inclusive of stepdown transformer, digital thermostat (modulation type) suitable for the given actuator, required length of 2Cx1.5Sqmm shielded communication cable, end flanges/matching flanges, additional supports, fixing accessories, dismantling the existing valves, thermal insulation, etc

-

-

-

... More
100 mm dia

1

-

-

... More
80 mm dia

1

-

-

... More
65 mm dia

5

-

-

... More
50 mm dia

34

-

-

... More
40 mm dia

31

-

-

... More
32 mm dia

27

-

-

... More
Supply and erection of Ball valves as per specification complete with end flanges / matching flanges, additional supports, fixing accessories, thermal insulation, etc.

-

-

-

... More
32 mm dia

18

-

-

... More
25 mm dia

171

-

-

... More
Supply, installation, testing & commissioning of Closed expansion tank with Pressurization Unit as per standards & requirements. Capacity 2000 Ltrs. Tank shall be complete with 0.5 HP Pumps required in the configuration of 1 working + 1 Stand By. The cost shall include necessary valve package & control logic panel for pump automation

2

-

-

... More
Supply, installation testing & commissioning of Bourdan Tube Pressure Guages (ALL SS TYPE) Pressure guages shall be of Bourdon (100 mm) type with range selected so that normal operation is near to middle of the scale. Syphons and cocks to be provided along with SS snubber.

224

-

-

... More
Supply, installation testing & commissioning of Thermometers - Dial Type - 4" Dia (ALL SS TYPE) Thermometers of approved make & shall be of mercury in steel type with range suitable for the temperature services. It should be installed in the thermowells as explained in the tender specifications. Extension nipple shall be provided for a minimum depth of 100 mm.

186

-

-

... More
Supply, installation testing & commissioning of Automatic Air Vents with Ball valve shall be installed at all high sections of piping as well as in the AHU room piping. The discharge from this air vents shall be piped via copper tubes of appropriate size to the nearest waste drain pipe.

157

-

-

... More
Gate Valves for Drain:

-

-

-

... More
32 mm dia

91

-

-

... More
25 mm dia

23

-

-

... More
20 mm dia

14

-

-

... More
Supply and installation of Insulatted Air Separators of size suitable 300NB to remove the dissolved air / gases from the chilled water loop with necessary flanges, washers, painting, etc. complete as required for Water cooled chiller

1

-

-

... More
Supply and installation of Insulatted Air Separators of size suitable 125NB to remove the dissolved air / gases from the chilled water loop with necessary flanges, washers, painting, etc. complete as required for Air cooled chiller

1

-

-

... More
CONDENSER WATER PIPE AND VALVES

-

-

-

... More
Condenser Water Piping.Suppling, fixing testing & commissioning of condenser water pipes of following sizes of MS C' Class along with nececessary clamps, vibration isolators and fittings sich as bends, tees etc. but excluding valves, strainers, gauges etc, adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc, as per slecification and as required complete in all respect. Note: The pipes size 150mm & below shall be M.S C class as per IS : 1239 and pipe size above 150mm shall be welded black steel pipe heavy class as per IS : 3589, from minimum 6.35mm thick M.S. sheet for pipe upto 350mm dia. And from minimum 7mm thick MS sheet for pipes of 400mm dia and above.

-

-

-

... More
400mm dia

250

-

-

... More
300 mm dia

10

-

-

... More
250 mm dia

110

-

-

... More
200 mm dia

25

-

-

... More
150 mm dia

15

-

-

... More
100 mm dia

50

-

-

... More
80 mm dia

10

-

-

... More
65 mm dia

15

-

-

... More
50 mm dia

30

-

-

... More
40 mm dia

10

-

-

... More
Supply fixing testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specification.Butterfly valveManual) with C I body SS disc nitrile sheet % O - ring & PN 16 pressure rating as per specified.

-

-

-

... More
400 mm dia

3

-

-

... More
350 mm dia

1

-

-

... More
300 mm dia

1

-

-

... More
250 mm dia

18

-

-

... More
200 mm dia

5

-

-

... More
150 mm dia

1

-

-

... More
125 mm dia

3

-

-

... More
100 mm dia

5

-

-

... More
80 mm dia

1

-

-

... More
65 mm dia

2

-

-

... More
50 mm dia

5

-

-

... More
40 mm dia

1

-

-

... More
Supply fixing testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specification. Non-Return Valve with dual plate of C I body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating as specified.

-

-

-

... More
300 mm dia

1

-

-

... More
250 mm dia

3

-

-

... More
200 mm dia

1

-

-

... More
Design, Supply, installation, testing and commissioning of Balancing Valve shall be of factory calibrated direct, acting, automatic pressure compensation type. Each valve shall limit flow rates to within ± 5 % accuracy, regardless of the system pressure fluctuations. Rate shall inclusive of additional supports, fixing accessories, thermal insulation, etc.

-

-

-

... More
300 mm dia

1

-

-

... More
250 mm dia

9

-

-

... More
200 mm dia

4

-

-

... More
Supply and erection of ‘Y’ type strainer with removable stainless steel screen with 3mm perforation and permanent magnet, drain piping. Rate shall inclusive of matching flanges, additional supports, fixing accessories, thermal insulation, etc.

-

-

-

... More
300 mm dia

1

-

-

... More
250 mm dia

3

-

-

... More
200 mm dia

1

-

-

... More
Supplying, fixing, testing and commissioning of following sizes Motorized butterfly valve with CI Boddy, SS Disc, O-ring and minimum PN-16 pressure rating, conforming to BS 5155, IS 13095, with IP-55 actuator, capable of accepting upto 10V DC, and upto 20mA electric signal and providing simillar transduced feedback output to control system as required.

-

-

-

... More
300 mm dia

1

-

-

... More
250 mm dia

9

-

-

... More
200 mm dia

4

-

-

... More
Supply and installation of Pot strainer of size suitable for 400NB pipeline to remove the dirt particles in the condenser water loop with necessary flanges, washers, painting, etc. complete as required

1

-

-

... More
Supply, installation testing & commissioning of Flow Switch

-

-

-

... More
Flow switchsuitable for 250 mm dia pipe

3

-

-

... More
Flow switchsuitable for 200 mm dia

6

-

-

... More
Flow switchsuitable for 125 mm dia

2

-

-

... More
Supply, installation testing & commissioning of Flexible connections rubber belows at Chiller Outelet, inlet & also at pump discharge as per the following sizes (In mm dia). Pressure rating of PN16 to be considered.

-

-

-

... More
250 mm dia

18

-

-

... More
200 mm dia

18

-

-

... More
125 mm dia

12

-

-

... More
Supply, installation testing & commissioning of Thermowells. Extension shall be provided for a minimum depth of 100 mm. There should be a minimum projection of 25 mm over and above insulated pipe.

4

-

-

... More
Supply, installation testing & commissioning of Binder type Test Points. Extension nipple shall be provided for a minimum depth of 100 mm. There should be a minimum projection of 25 mm over and above insulated pipe.

10

-

-

... More
DRAIN PIPE WITH INSULATIONS

-

-

-

... More
Supply Insulated PVC Condensate Drain piping as per specification as mentioned in the document insulated same as chilled water piping but without polyshield covering.Consider drip pans with drian pipe .Entire draine pipe needs to be insulated with 6mm thick closed cell Nitrile rubber. 65 mm dia

280

-

-

... More
Supply Insulated PVC Condensate Drain piping as per specification as mentioned in the document insulated same as chilled water piping but without polyshield covering.Consider drip pans with drian pipe .Entire draine pipe needs to be insulated with 6mm thick closed cell Nitrile rubber. 50 mm dia

280

-

-

... More
Supply Insulated PVC Condensate Drain piping as per specification as mentioned in the document insulated same as chilled water piping but without polyshield covering.Consider drip pans with drian pipe .Entire draine pipe needs to be insulated with 6mm thick closed cell Nitrile rubber. 40 mm dia

280

-

-

... More
Supply Insulated PVC Condensate Drain piping as per specification as mentioned in the document insulated same as chilled water piping but without polyshield covering.Consider drip pans with drian pipe .Entire draine pipe needs to be insulated with 6mm thick closed cell Nitrile rubber. 32 mm dia

240

-

-

... More
Supply Insulated PVC Condensate Drain piping as per specification as mentioned in the document insulated same as chilled water piping but without polyshield covering.Consider drip pans with drian pipe .Entire draine pipe needs to be insulated with 6mm thick closed cell Nitrile rubber. 25 mm dia

150

-

-

... More
Supply Insulated PVC Condensate Drain piping as per specification as mentioned in the document insulated same as chilled water piping but without polyshield covering.Consider drip pans with drian pipe .Entire draine pipe needs to be insulated with 6mm thick closed cell Nitrile rubber. 19 mm dia

10

-

-

... More
BTU METER AND TENNANT BILLING SYSTEM

-

-

-

... More
Supply, installation, testing and commissioning of BTU Meter - to measure the HVAC Consumption Purpose. The Unit shall include an Heat Meter Integrator, Ultrasonic type Flow meter, matched pair of Temperature Sensors (along with the protection pockets). The Integrator shall have Battery backup for 12 years, Data Logging for 15 years, 230V AC power supply provision, 8 Digit LCD Display The Unit should be capable of displaying the CHW Flow Rate, BTU / Hr, KWH, CHW Temperature. The Unit shall be with IP55 grade of protection ( Maximum Pressure drop across BTU meter 0.2 WC) The BTU Meter shall be MID approved In-Line Flange Connection type . The Integrators shall be capable of communicating on a communication bus to the BMS on one of Standard Open Protocols such as MODBUS / LON etc a) Inline Flow Meter, b) Match Pair Sensors c) Heat Integrator d) Minimum 4 Data / Meter to Master Contoroller - T1 / T2 / Flow / KWH - with 2 mtr 2C shielded communication cable

-

-

-

... More
Btu Transmitters as per the specification for tenant billing. Btu Meters shall consist of following items of following sizes:-

-

-

-

... More
300 mm dia

1

-

-

... More
250 mm dia

1

-

-

... More
200 mm dia

1

-

-

... More
150 mm dia

1

-

-

... More
125 mm dia

1

-

-

... More
100 mm dia

1

-

-

... More
80 mm dia

1

-

-

... More
65 mm dia

5

-

-

... More
50 mm dia

34

-

-

... More
40 mm dia

21

-

-

... More
32 mm dia

9

-

-

... More
25 mm dia

69

-

-

... More
Power supply cable for BTU Meters - 3 core 1.5 sqmm shielded FRLS cable including glands along with 25 mm pvc conduit

6300

-

-

... More
CHEMICAL DOSING SYSTEM

-

-

-

... More
AUTOMIZED CHEMICAL DOZING SYSTEM - FOR OPEN LOOP (CONDENSER WATER CIRCUIT). Below are the plant room details. (refer Schematic layout and Plant room layout for additional info) 1. 475 TR X 3 Nos Water cooled chillers 2. Flow rate across condenser / cooling tower - 1662 GPM each 3. chiller located on podium-01 and cooling tower located on terrace. System shall consist of all associated accessories as per below list as minimum for effective performance

-

-

-

... More
pH Control System, Acid Dosing with following components

-

-

-

... More
pH Sensor, Make: PMI/Equivalent, range: 0-14, output: mV, Body MOC: PVC

-

-

-

... More
pH Transmitter, Make: PMI/Equivalent Power: 24V DC ; Output: 4-20mA

-

-

-

... More
Metering Pumps, Make: Milton Roy/Equivalent, Max. Flow: 4LPH, Max. Injection Pressure: 5.5kg/cm2, PP/Teflon Liquidend, with accessories like foot valve, strainer, injection valve, antisyphon valve.

-

-

-

... More
PE/FRP Storage Tank, 60lts, lid with facility to mount the metering pump

-

-

-

... More
LDPE Tubing from Dosing Pump to Sampling Line Dosing Point.

-

-

-

... More
ORP Control System, Hypo Dosing with following components

-

-

-

... More
ORP Sensor, Make: PMI/Equivalent, range: -1000-1000mV, output: mV, Body MOC: PVC

-

-

-

... More
ORP Transmitter ; Make: PMI/Equivalent Power: 24V DC ; Output: 4-20mA

-

-

-

... More
Metering Pumps, Make: Milton Roy/Equivalent, Max. Flow: 4LPH, Max. Injection Pressure: 5.5kg/cm2, PP Liquidend, with accessories like foot valve, strainer, injection valve, antisyphon valve.

-

-

-

... More
PE Storage Tank, 60lts, lid with facility to mount the metering pump

-

-

-

... More
LDPE Tubing from Dosing Pump to Sampling Line Dosing Point

-

-

-

... More
Conductivity Control System with following components

-

-

-

... More
a. Conductivity Sensor; Make: PMI/Equivalent Wetted materials – PVC b. Electrodes – SS c. Conductivity Transmitter, Make: PMI/Equivalent Power: 24V DC ; Output: 4-20mA Blowdown Control Valve, 2” Size, Make: PMI/Equivalent Antiscalant Dosing System with following components: Metering Pumps, Make: Milton Roy/Equivalent, Max. Flow: 4LPH, Max. Injection Pressure: 5.5kg/cm2, PP Liquidend, with accessories like foot valve, strainer, injection valve, antisyphon valve. PE Storage Tank, 60lts, lid with facility to mount the metering pump LDPE Tubing from Dosing Pump to Sampling Line Dosing Point. Non – Oxidising Biocide Dosing System with following components: Metering Pumps, Make: Milton Roy/Equivalent, Max. Flow: 4LPH, Max. Injection Pressure: 5.5kg/cm2, PP Liquidend, with accessories like foot valve, strainer, injection valve, antisyphon valve. PE Storage Tank, 60lts, lid with facility to mount the metering pump LDPE Tubing from Dosing Pump to Sampling Line Dosing Point. Bio-Dispersant Dosing System with following components: Metering Pumps, Make: Milton Roy/Equivalent, Max. Flow: 4LPH, Max. Injection Pressure: 5.5kg/cm2, PP Liquidend, with accessories like foot valve, strainer, injection valve, antisyphon valve. PE Storage Tank, 60lts, lid with facility to mount the metering pump LDPE Tubing from Dosing Pump to Sampling Line Dosing Point. Corrosion Inhibitor Dosing System with following components: Metering Pumps, Make: Milton Roy/Equivalent, Max. Flow: 4LPH, Max. Injection Pressure: 5.5kg/cm2, PP Liquidend, with accessories like foot valve, strainer, injection valve, antisyphon valve. PE Storage Tank, 60lts, lid with facility to mount the metering pump LDPE Tubing from Dosing Pump to Sampling Line Dosing Point. Electrical Control Panel comprising of Controller with RS 485 Port Safety Circuits and Terminals for cable connections.

-

-

-

... More
Control Skid To house the above mentioned items along with required piping and internal cabling

1

-

-

... More
COOLING TOWER CIRCUIT & CHILLED WATER CIRCUIT DOSING SYSTEM

-

-

-

... More
Pre-Cleaning & Passivation with chemicals For open loop

5

-

-

... More
Surfactant clenaing with VOD 10

20

-

-

... More
Bioflushing with BIONIL 9120

35

-

-

... More
Low pH clenaing with SCALNOR

85

-

-

... More
Passivation with CORROCIL 9330

35

-

-

... More
Service charges

1

-

-

... More
Regular treatment for open loop system (quantities are for 1 year)

-

-

-

... More
For open loop

5

-

-

... More
Phosphanate based anti scalent SCACIL 9800

900

-

-

... More
Corrosion inhibitor CORROCIL 9330

150

-

-

... More
Bio-dispersant SCACIL 9010

75

-

-

... More
Oxydizing chloro bromin based biocide

120

-

-

... More
Non-oxidizing isothozilin based biocide BIONIL 9120

200

-

-

... More
PH corrector- 98% concentration H2SO4

1600

-

-

... More
LOWDISE DUCTING WORKS

-

-

-

... More
SHEET METAL DUCTING Supply, installation balacing and commissoning of factroy fabricated GSS sheet metel rectangular/ round duct complete with neoprene rubber gaskets, elbows, spliter dampers, vanes, hangers suppots, etc. As per approved drawings and specifications of follwing sheet thickness complete as required. Duct pressure test to be considered (0-500 Psi) with nessarry supporting materials part of this item (Vendor need to be submit detailed report before appling insulation. Third party air balancing to be considered part of this item.

-

-

-

... More
0.63 MM ( With Ductmate Flanges)

2683

-

-

... More
0.8 MM ( With Ductmate Flanges)

1581

-

-

... More
1.0 MM ( With Ductmate Flanges)

637

-

-

... More
1.25 MM (With Ductmate Flanges)

14

-

-

... More
Supply and installations of factory made Powder coated sheet metal Flat oval Spiral ducting with (factory made internal thermal insulation -9 mm thick closed cell material to be considered cost of this shall be inclusive of this item) fittings, Wire supports, The factor of wire to suit to duct weight, with necessary anchor fasteners and hook arrangements with suitable rod thickness,etc., confirming SMACNA standards. Duct should be fabricated by using CNC machines, Including necessary civil works as per site condition. Exposed ducts color to match interior requirement. Colour shall be confirmed by Architect. The joints shall be 100% leak proof. The duct should be factory made internally insulated with 9mm thick antimicrobial nitrile rubber. (Light test need to considered for elliptical ducts)

-

-

-

... More
24 G ( With Ductmate Flanges)

76

-

-

... More
22 G ( With Ductmate Flanges)

102

-

-

... More
20 G (With Ductmate Flanges)

90

-

-

... More
18 G (With Ductmate Flanges)

30

-

-

... More
LOWDISE AIRTERMINAL WORKS

-

-

-

... More
AIR TERMINAL DEVICES Supply, fixing testing commissioning of Return air diffusers of powder coated aluminium without volume control dampers with anti smudge ring and removable core.

15

-

-

... More
Supply and installation of Powder coated extruded aluminium continuous linear grilles as per specifications. The rate shall inclusive without collar damper, necessary fixing and supporting arrangement for the grilles

194

-

-

... More
Supply and installations of Powder Coated Curved grilles with collar damper for supply distribution in Oval duct ( colour for the grill to b confirmed by Arch/ PMC team before placing the order) . Deflection of the grille shall be 0 / 15 / 30. same will be confirmed later.

10

-

-

... More
Supply, installation of Collar Dampers of opposed blade type made out of Aluminium alloy extrusion with anodised matt black finish (quantity including for diffusers & grills)

39

-

-

... More
Supply, installation of Fresh air / Exhaust Louvers with bird wire mesh

78

-

-

... More
Supply and installation of Powder coated extruded aluminium Disc Valve of the following diameter for exhaust air. The rate shall be inclusive of volume control damper and necessary fixing and supporting arrangement for the valve. Size: 150mm Dia neck

336

-

-

... More
Supply, installation of JET NOZZLES for supply air distribution - adjustable type

-

-

-

... More
350 mm dia

10

-

-

... More
300 mm dia

2

-

-

... More
Supply, installation of Insulated Flexible Ducting Factory Fabricated Insulated Flexible made out aluminium for connecting from main duct to diffuser box. The length of the flexible duct shall be around 1.0 to 1.8 mtr. The flexible duct shall me made of triple lamination of aluminium foil, polyester and metalised polyester film permanently bonded to a coated spring steel wire helix. The exterior shal be wrapped with 25mm thick 16 kg / cum fibreglass insulation. The outer insulation jacket / vapour barrier made of fibreglass reinforced metalised polyester film laminate.

-

-

-

... More
150 mm dia

70

-

-

... More
250 mm dia

5

-

-

... More
300 mm dia

5

-

-

... More
Supply installations of Butterfly Dampers made out of 20G GI sheets similar duct specifications

-

-

-

... More
150mm dia

336

-

-

... More
200 mm dia

1

-

-

... More
250mm dia

1

-

-

... More
300mm dia

1

-

-

... More
Supply and installations of low leakage Volume Control Dampers with TDF flanges having Square slot for Carriage Bolt fixing suitable for connecting to the ducts on both sides. Completely factory - made, 1.6 mm thick opposed blade GSS interlocking blades, 1.6 mm thick GSS frame, High quality plastic bushes, Embossed Lettering on Handle plate for Blade open level indication. The pressure drop across the dampers shall not exceed 1.5 mm of wg at 1500 fpm for the cross section area of 1 sqm.

53

-

-

... More
Supply, installation, testing and balancing of GSS OVAL shape Volume Control Dampers all dampers should of robust construction with multi opposed blade construction of low leakage type. The outer casing shall be made out of 1.6mm.thick GI welded frame with flat type 1.6mm with operating handle for Supply air duct branches in accordance with the approved shop drawings.

3

-

-

... More
Supply, installation, testing and balancing of Pressure Relief Dampers made out of 1.6 mm thick galvanized sheet steel frame and blades of 1.6 mm galvanised sheet steel with linkages capable of maintaining constant pressure at various airflows & close upon decrease in differential pressure. The damper shall be designed to provide pressure relief at 50 Pascals & 15 m/s velocity.

5

-

-

... More
Supply and installations Motorised On/off type volume Control Dampers made out of 100 x 40 x 1.55 mm thick galavanised steel frame and blades of 1.55 mm galavanised sheet steel

6

-

-

... More
Supply & installation of spring return type damper actuator with control panel along with BMS compatability for switch On/Off, Torque to be selected based on Damper size in NM.

10

-

-

... More
Supply and installations Motorized Modulating type low leakage air dampers made out of 100x40x1.55mm thick galvanised steel frame & blade for fresh air modulation with actuator complete with all accessories like Actuator,control panel etc and any necessary requirement which can perform the controlling the Damper. It shall be integrated with Co2 sensor and based on CO2 levels, damper shall be modulate. (Co2 sensor provided by BMS scope). The damper shall be set at minimum 100 % fresh air supply and it shall modulate from 100 to 130 % fresh air supply as per the signals recieved from the CO2 sensor.

38

-

-

... More
Supply and installations testing & commissioning of actuator with control panel should be compatible for third party BMS integration .necessary fire integrator should be consider in part HVAC vendor scope

71

-

-

... More
Supply,installation,testing & comissioning of 525 x 525 x 450 mm High Sheet Metal Spill air boxes made out of 26 GI sheet for connecting the diffuser outlet & flexible connection from the main duct. Plenum box shall be internally insulated with 6mm thick class O closed cell nitrile rubber insulation. Cost of insulation shall be included is this item only. Spill air boxes shall be constructed with Cross mark grooves for additional stability

5

-

-

... More
Supply,installation,testing & comissioning of 1000 x 150 x 450 mm High Sheet Metal Spill air boxes made out of 26 GI sheet for connecting the diffuser outlet & flexible connection from the main duct. Plenum box shall be internally insulated with 6mm thick class O closed cell nitrile rubber insulation. Cost of insulation shall be included is this item only. Spill air boxes shall be constructed with Cross mark grooves for additional stability

5

-

-

... More
Supply, installation, testing and commissioning of UL555 Listed and certified classified dynamic rated combination fire smoke damper. Damper shall be Multi-blade type damper with 180 minutes fire rating. Damper construction shall include 16 gauge galvanized steel frames and blades, Resettable resuable link, SS jamb seals and axle bearings, Silicon blade seals, steel axle. Blade type shall be 3V or Airfoil type. UL 555S Leakage Rating Leakage Class: I All dampers shall bear the AMCA Certified Ratings Program seal for Air Performance.

31

-

-

... More
Supply and installations of Actuators for above fire dampers- HIGH TORQUE TYPE-10 NM.

48

-

-

... More
Supply and installations of Actuators for fire dampers- MEDIUM TORQUE TYPE 5 NM.

8

-

-

... More
AHU room - Fire damper control panel with Modbus over RS485 output for BMS compatibility. Each panel shall be located in AHU room and shall control 4 to 6 fire dampers. It should take one fire input and from the FD panel, output to be provided to trip the dampers, AHU & TFA. (If the fire damper panel is off then AHU & TFA should not turn ON). - This shall be BMS compatible with Modbus over RS485 output

1

-

-

... More
UPS & Server Room- Fire damper control panel with Modbus over RS485 output for BMS compatibility. Each panel shall be located in UPS room and shall control 3 or 5 fire dampers. It should take one fire input and from the FD panel, output need to provided to trip the dampers - This shall be BMS compatible with Modbus over RS485 output

4

-

-

... More
Supply, installation, testing and commissioning of Fusible link type Fire Damper of 180 minutes fire resistant complete with all standard accessories. Fire damper as per UL 555-S, outer shell constructed with 1.6mm thick galvanized steel frame and the blade/Leaf with 1.6mm thick GSS in accordance with the GFC/ shop drawings

4

-

-

... More
Supply, laying, testing & commissioning of MS insulated MS sheathed, steel armoured ,aluminium conductors 1100 V grade power cables. The cables shall be laid in tray built up trench etc., Rate shall exclude the cost of tray. '3 runs of 2.5 sq.mm HFLS Cu Wire in 19 mm dia MS Conduit for damper panel to Fire dampers

160

-

-

... More
Canvas connection : Supply, installation of Heavy duty double layered Canvas connection consisting of a flame retardnat fabric secured between galvanized sheet metal on either side by a double lock seam inserted between the equipment / Duct to provide wear resistant air tight flexible connection to eliminat vibrations, noise and rattles with fire rating EN532 and 533

29

-

-

... More
Supply, installation of Uninsulated Flexible duct - 150 mm dia for toilet disc valve connection

510

-

-

... More
Supply, installation of Back Draft Dampers made out of 100 x 40 x 1.55 mm thick galvanised steel frame and blades of 1.55 mm galvanised sheet steel

47

-

-

... More
LOWSIDE DUCT INSULATION MATERIALS

-

-

-

... More
Supply and installation of (Accoustic) Duct liner (Insulation) of specified thickness of Elastromeric Rubber Insulation manafactured as per ASTM E 84 test & which should also meet NFPA 90A supplementary materials for air distribution system which should not absorbs less 0.2% water by volume (ASTM c 209), should not support microbial growth (ASTM C1071, G21, G22) and should emit objectionable odors (ASTM C 665) and should have thermal conductivity of 0.27 ( R - 2.78 in 3.4" thickness) and water vapor permeance of 0.10. - Class "1" Material-.All joints of the Insulation material should be further covered with 50 mm wide 3 mm thick self adhesive tape made of similar material & Black Cotton Tape shall not be used. 15mm Thick

340

-

-

... More
Supply and installation Thermal (Insulation) of specified thickness of Elastomeric Rubber Insulation manufactured as per ASTM E 84 test & which should also meet NFPA 90A supplementary materials for air distribution system which should not absorbs less 0.2% water by volume (ASTM c 209), should not support microbial growth (ASTM C1071, G21, G22) and should emit objectionable odors (ASTM C 665) and should have thermal conductivity of 0.27 ( R - 2.78 in 3.4" thickness) and water vapor permeance of 0.10. Joints should be sealed with 100 mm wide 3mm thick self adhesive tape (Black Cotton Tape not acceptable). Class "O" Material-Material should be FM approved. For internal ducts ,insulation should be provided without any patches . For under deck insulation, surface should be dust free .One coat adhesive to be provide on surface & material should be provided. 9mm Thick

3450

-

-

... More
Supply and installation Thermal (Insulation) of specified thickness of Elastomeric Rubber Insulation manufactured as per ASTM E 84 test & which should also meet NFPA 90A supplementary materials for air distribution system which should not absorbs less 0.2% water by volume (ASTM c 209), should not support microbial growth (ASTM C1071, G21, G22) and should emit objectionable odors (ASTM C 665) and should have thermal conductivity of 0.27 ( R - 2.78 in 3.4" thickness) and water vapor permeance of 0.10. Joints should be sealed with 100 mm wide 3mm thick self adhesive tape (Black Cotton Tape not acceptable). Class "O" Material-Material should be FM approved. For internal ducts ,insulation should be provided without any patches . For under deck insulation, surface should be dust free .One coat adhesive to be provide on surface & material should be provided. 13mm Thick

150

-

-

... More
Supply and erection of Thermal Insulation with Protection against UV / Mechanical damage of exposed duct. The insulation shall be closed cell nitrile rubber with treated woven glass fibre covering. Rate shall inclusive of Two coats of synthetic enamel weather proof paint shall be applied over the insulation and the adhesive as per manufacturers recommendation. 19mm thickness of the insulation.

600

-

-

... More
Supply and erection of Thermal Insulation with Protection against UV / Mechanical damage of exposed duct. The insulation shall be closed cell nitrile rubber with treated woven glass fibre covering. Rate shall inclusive of Two coats of synthetic enamel weather proof paint shall be applied over the insulation and the adhesive as per manufacturers recommendation. 25mm thickness of the insulation.

2760

-

-

... More
SITC of underdeck insulation for all AC areas exposed to directly Sun shall be provided with 50 mm thick TF quality Expanded Polystyrene slab or material of equivalent u value. The material shall be conform to IS:4671 & shall be of type ‘N’ unless specified otherwise. The apparent density shall be of 24 Kg/m³. The thickness of the material to be of 50mm. The vendor to include the cost of all material related to installation of the same for the top slab level with cleaning and making surface dust free, applying adhesive and providing 600x600 mm wire mesh grid with 26 G GI wire along with EPS slabs pasting on the surface. Vendor to ensure the installation as per engineer IN charges satisfaction.

3700

-

-

... More
Supplying ,fixing acoustic lining on wall and ceiling of AHU/ Chiller Plant room with 50mm thick density 32kg/cu.m resin bonded glass fiber insullation friction fixed in 610mmx610mm frame work made of 25x50x50x50x25mm made out of 0.6mm thick GI sheet U shaped channel and covered with reinforced fiber glass tissue and finished with 0.8mm perforated alumimuim sheet etc. complete as required as per specification

650

-

-

... More
Kitchen exhaust ducting and accessories

-

-

-

... More
MS Ducting - SS304 grade material 16 G with complete joints, & MS supports at every 1.5 mts capable of taking 600 kgs point load - Floor,Shaft & Terrace Area. Necessary scafollding required for erecting above within the shafts from 16th floor to terrace should be considered in the scope of works. Fire rated gasket material to be used for duct joining. Mockup to be provided for the duct support arrangement along with duct joints before going ahead.

280

-

-

... More
Grease Collection Box near the unit. Construction of Grease Collection Box should be similar to same as Ducting specified above

2

-

-

... More
20 Inches x 20 Inches Trap Door fabricated of same material / specs as Ducting specified above. Acess panel shall have a gasket which can sustain 1500 deg F (815 deg C) temperature. Same need to be located in the kitchen area, shafts , units etc

2

-

-

... More
Volume control Damper made out of MS material (higher than ducting material) for air balancing. Frame: High quality Stainless Steel sheet (Grade 304/316L) of thickness 16 G depending on size Frame shall be made of 125mm depth and standard flange height of 25mm. Blades shall be single skin ridge shaped blade constructed out of 16G thick S.S sheet as standard.

8

-

-

... More
Pressure relief damper for kitchen exhaust duct. In case of pressure build up in the kitchen, the damper shall release the pressure to the atmosphere. Needs to fixed on the exhaust duct near the exhaust fan with all accessories, supports, etc. Shall be made of 16 G GI of the following sizes.

1

-

-

... More
MS duct insulation with Al. Foil faced fibre glass wool 25 mm thick, 32 kg /m3 density

950

-

-

... More
VENTILATION WORKS

-

-

-

... More
Supply installation testing & commissioning of Fire Rated Tube axial exhaust Fan with motor including casing made of Hot dipped Galvanized Iron, motor, with adjustable pitch die cast aluminium impeller (Hub and blades) Casing position shall be as per the job requirement and shall be marked on the fan assembly of the following capacities. Note: The Fan assemble along with motors should be tested for Temperature range: 300 deg C/2Hours for Smoke Evacuation. Cost inclusive of proposed fan motor suitable KW Starter panel for exhaust fan with allother associated accessories as required as per the site conditions with 2NO + 2NC potential free contacts, connectors, contactors with wiring etc are to be provided for ON /OFF & indication for ON OFF & TRIP to be provided.

-

-

-

... More
30000Cfm, 25mm ESP - Smoke Extraction

2

-

-

... More
22000Cfm, 25mm ESP -Smoke Extraction

2

-

-

... More
Supply installation testing & commissioning Ductable axial flow units incorporated with/without sound attenuators , flow straighteners according to the type, bird screen and cowl and suitable for outdoor installation and mounted on a steel frame work with vibration isolation cushy foot mountings of following capacitie. Cost inclusive of proposed fan motor suitable KW Starter panel for exhaust fan with allother associated accessories as required as per the site conditions with 2NO + 2NC potential free contacts, connectors, contactors with wiring etc are to be provided for ON /OFF & indication for ON OFF & TRIP to be provided.

-

-

-

... More
27000Cfm, 25mm ESP - Stairwell

2

-

-

... More
13300Cfm, 25mm ESP - Lift Lobby

2

-

-

... More
8000Cfm, 25mm ESP - Lift Well

7

-

-

... More
3800Cfm, 25mm ESP - Noise level of the fan should be less than 65dba@3M distance - Solid Waste Room (With attenuator)

1

-

-

... More
5000Cfm, 20mm ESP, Noise level of the fan should be less than 65dba@3M distance - Electrical Panel Room + Fire Pump Room + Transformer Room Exhaust (With attenuator)

3

-

-

... More
8500Cfm, 20mm ESP Noise level of the fan should be less than 65dba@3M distance- Domestic Pump Room Exhaust (With attenuator)

1

-

-

... More
Supply, Installation, Testing and Commissioning of Double skin cabinet type, inner skin and outer skin shall be minimum 1 mm thick pre-coated and pre plasticized sheets, Puff panel of 25 mm(+/-1mm) thickness, density of insulation shall be 48 Kg/sq.m, DIDW/SISW backward curve fan with motor shall be IE 4 type fan motor to suitable for VFD to rampup & ramp down the motor speed, (VFD in seperate line item) Fan total efficiency shall be minimum 75%, unit base with suitable size of coushy foot mounting, Motor winding shall be vacuum pressure impregnated for all motors. Insulated bearing on non-drive end for Motor frame of 315 and above shall be provided. fans are rated and tested in accordance with AMCA standard to meet the air and sound performance requirements, Selected Motor rating shall be minimum 15% above BKW.. Cost inculde at site perfromance test with OEM Engineer. Weather proof canopy should be provided for all units located on terrace. An extended canopy of 150 mm all around the unit to be considered. Cost inclusive of proposed fan motor suitable KW starter panel with DOL/Star-Delta starter and BMS compatible Variable Frequency Drive with controller with auto bye pass arrangement. The VFD shall have Frequency controller, Microprocessor based logic controller, integrated Software capable to control frequency based on the inputs from sensors, power cable from VFD to AHU, communication cable, Communication card (BACnet protocol) to transfer the entire data available on VFD to the third party BMS System. The VFD shall have IP-20 protection and panel shall have IP65 protection. (Outdoor mount type)

-

-

-

... More
Capacity of 7000 cfm Exhaust air unit- ESP 40mm Toilet Exhaust (DIDW Fans)

2

-

-

... More
Capacity of 8500 cfm Exhaust air unit- ESP 40mm Toilet Exhaust (DIDW fans)

2

-

-

... More
Capacity of 9000 cfm Exhaust air unit- ESP 125mm WITH SISW backward curved fan Kitchen Exhaust. Fan motor shall be outside the air stream.

3

-

-

... More
Capacity of 2400 cfm Fresh air unit- ESP 25mm with 10Micron Prefilter for Solid Waste Room Fresh air (DIDW Fans). Fan shall be ceiling suspended type

1

-

-

... More
Capacity of 4500 cfm Fresh air unit- ESP 25mm with 10Micron Prefilter for Pump Fire Room Fresh air (DIDW Fans). Fan shall be ceiling suspended type

1

-

-

... More
Capacity of 7500 cfm Fresh air unit- ESP 25mm with 10Micron Prefilter for Domestic Pump Room Fresh air (DIDW Fans). Fan shall be ceiling suspended type

3

-

-

... More
Outdoor mount Dry Scubber (6000 CFM each). The Scrubber shall be Electrostatic precipitation technology based dry type air cleaner to remove oil, smoke & fumes from the Kitchen exhaust air. Unit shall be made of 18 gauge galvanized sheet, high bake epoxy powder coated. having prefilter, tungsten wire ionizers & collector plates and having a average effeciency of 90% to 95%. The control panel must have provision for auto restart in case of power failure, short circuit arc protection with automatic power restoration to prevent overloading & 'NO' potential free contact for monitoring on BMS system. The units must be selected to not exceed face velocity of 550 FPM & must have passed third party ASHRAE testing for similar capacities. MS angle supports to be considered for supporting the dry scrubbers on the terrace. vertical stacking arrangement to be considered to locate 3 nos of dry scrubbers one above the other.

5

-

-

... More
DUCT MOUNTED RECTANGULAR IN LINE FAN UNIT:

-

-

-

... More
All sheet metal Double Skin Rectangular In Line Centrifugal Fans fabricated out of 1 mm thick Galvanized Steel for use as Exhaust/Outside Air or fresh air Unit. The unit shall be complete with flanged connection on either side, fixing bracket, fan motor assembly, power cabling with required plug of around 5m length from the unit to power socket provided by other agencies etc.. suitable for operation through on 220 V, 1 Ph, 50 Hz AC supply. The noise from Inline Fan shall not exceed 50 dbA. The cost of the Inline Fan also includes DOL Starter with On/off push button staton, A/M Status and PF/relays etc for BMs integration and along with inbuilt fan regulator.

-

-

-

... More
300 Cfm exhaust fan - 10 mm external static Inline fan with all necessary supports. Unit shall be provided along with fire retardant flexible canvass with Zip, Cowl piece with bird mesh and supporting arrangements.

1

-

-

... More
200 Cfm exhaust fan - 10 mm external static Inline fan with all necessary supports. Unit shall be provided along with fire retardant flexible canvass with Zip, Cowl piece with bird mesh and supporting arrangements.

1

-

-

... More
800 Cfm toilet exhaust fan - 20 mm external static Inline fan with all necessary supports. Unit shall be provided along with fire retardant flexible canvass with Zip, Cowl piece with bird mesh and supporting arrangements.

39

-

-

... More
800 Cfm battery exhaust fan - 20 mm external static Inline fan with all necessary supports. Unit shall be provided along with fire retardant flexible canvass with Zip, Cowl piece with bird mesh and supporting arrangements.

1

-

-

... More
Supply fixing testing & commissioning of Hyderagen sensor with sequential timer suitable control panel to operate Battery room exhaust fan at regular 2hrs interval fan run 5.0 minutes and when increse the Hyderagen level above 1% switch ON the fan. Controller shall have bypass mode to switch ON / OFF manually with necessary control wiring. panel shall provided with BMS compartability via Modbus over RS485.

1

-

-

... More
1800 Cfm exhaust fan - 20 mm external static Inline fan with all necessary supports. Unit shall be provided along with fire retardant flexible canvass with Zip, Cowl piece with bird mesh and supporting arrangements.

1

-

-

... More
250 Cfm fresh air fan with inbuilt MERV-8 & MERV-13 filters and 25 mm external static Inline fan with all necessary supports. Unit shall be provided along with fire retardant flexible canvass with Zip, Cowl piece with bird mesh and supporting arrangements.

1

-

-

... More
600 Cfm fresh air fan with inbuilt MERV-8 & MERV-13 filters and 25 mm external static Inline fan with all necessary supports. Unit shall be provided along with fire retardant flexible canvass with Zip, Cowl piece with bird mesh and supporting arrangements.

1

-

-

... More
Supply, installation testing & commissioning EUROVENT CERTIFIED Floor mounted Treated fresh air units having following specifications. Frame Structure consisting of 45mm Extruded Aluminium Thermal break profile: Capacity Panel: 45mm +/- 2mm thick double skin sandwich panels with Rockwool insulation of density 60 kg/cum , The sheet thickness shall be minimum 0.8 mm for the outer skin and 0.8 mm thickness for the inner skin of GI . with Plenum box for fresh air intake. Filtration Section shall be provided with 2 stage washable type of 'MERV8 ' first stage and 'MERV14' final stage. Coil Section: Chilled water coil Minimum 8 row deep constructed with Aluminium fins of minimum 0.11mm thickness and copper tubes of minimum 29Guage thickness. Copper tube shall be 9.6mm or 12.5mm diameter. The coil face area shall not exceed 2.5m/sec. Coil Section is Equipped with Factory Fitted Energy Valve / PIBV , UV Lamp considered along with the unit. Drain Pan: Condensate drain pan shall be fabricated from 20 G SS 304 powder coated, insulated with 19 mm thick closed cell elastomeric insulation. Fan Section: Direct drive backward curved EC fan ( Electronically commutated ) with permanent magnet brushless DC motor for stepless variation of speed of fan based on temperature sensor inputs. The fan section shall be provided with limt switch for safety to shut off fan during Opening of access door. Electrical starter Panel with Auto /Manual switch and incomer power terminal along with provision for fire damper on/ off withinAHU room. Instrumentation Kit to be provided to give out the following option.

-

-

-

... More
70 TR - 12600 CFM with 40mm ESP ( Kitchen fresh air )

2

-

-

... More
36TR/6500CFM with 65mm ESP ( Office Area Fresh air)

3

-

-

... More
47TR/8500CFM with 65mm ESP ( Office Area Fresh air)

2

-

-

... More
58TR/10440CFM with 65mm ESP ( Office Area Fresh air)

2

-

-

... More
Supply, installation, testing and commissioing of Suitable IP55 VFD & PID controller (A0-2.Ai-4, DO-5,DI -5) with by pass star delta starter for operation of Ahus Supply air fan, auto/manual switch, saftey switch, ammeter, voltmer and energy meter, disconnet switch VFD/star delta units shall be provided with factory fitted Active Harmonic Filters meeting IEEE 519 standards and THDI not exceeding 5%, panel shall be as per the IS standard of electrial standard and, CRCA-14 G / 2mm thick Sheet steel enclosed, indoor floor mounted free standing cubicle type & CNC fabricated, required BMS compatable for the above operation.

1

-

-

... More
Supply, installation, testing and commissioing of suitable fire rated Double compression cable gland for the above both the end termination

650

-

-

... More
Supply, installation, testing and commissioing of Emergency Lockable Push button station for the above, Fire rated type with required GI angle iron support

15

-

-

... More
Supply, installation, testing and commissioing of Emergency Lockable Push button station cabling for the above, 3 core 1.5 square XLPE copper armoud fire rated cable length shall be 20rmt between motor to Push button

150

-

-

... More
Supply, installation, testing and commissioing of MS channel support with two coat of enamal painting for Unit supports, Support shall be with cushy foot mounting or spring mounting as per the manufacter standard Extra supports otherthan installation drawing. Consider this line item.

1000

-

-

... More
Supply, installation and commissioning of Air curtains suitable for 230V/50Hz/AC power supply complete with aluminimum centrifugal flow fans wheel and double shaft motors, heavy duty to suit the following sizes of Rolling shutter/Door for dust barrier and for a minimum inside temperature of 29ºC internal barrier and noise level should not exceed more than 55dB (A). 6 feet length, Air Flow: 1300 m3/hr, Air Velocity : 21-25 m/s ; Noise level 60DB for (Door Ht. - 3.5 mtrs.)

2

-

-

... More
Supply, installation and commissioning of Air curtains suitable for 230V/50Hz/AC power supply complete with aluminimum centrifugal flow fans wheel and double shaft motors, heavy duty to suit the following sizes of Rolling shutter/Door for dust barrier and for a minimum inside temperature of 29ºC internal barrier and noise level should not exceed more than 55dB (A). 4 feet length, Air Flow: 1300 m3/hr, Air Velocity : 21-25 m/s ; Noise level 60DB for (Door Ht. - 3.5 mtrs.)

3

-

-

... More
LT CABLES & END TERMINATIONS

-

-

-

... More
Supply, laying, testing & commissioning of the following sizes of 1.1KV grade Copper Conductor armoured power cables Insulation of XLPE above 25Sqmm and Class A PVC below 25Sqmm laid on trays, ceilings, walls trenches, ground etc., with necessary clamps, cable ties, fasteners, identification tags, cable marking as required. Cost of sand, bricks, excavation should not be included in the rate quoted & measured separately.

-

-

-

... More
1C X 185 sqmm Copper flexible cable

900

-

-

... More
1C X 150 sqmm Copper flexible cable

400

-

-

... More
1C X120 sqmm Copper flexible cable

5

-

-

... More
1C X95 sqmm Copper flexible cable

5

-

-

... More
1C X 25 sqmm Copper flexible cable

600

-

-

... More
1C X 16 sqmm Copper flexible cable

600

-

-

... More
1C X 10sqmm Copper flexible cable

400

-

-

... More
1C X 6sqmm Copper flexible cable

100

-

-

... More
4CX16sq.mm 2XWY

120

-

-

... More
4CX10sq.mm 2XWY

120

-

-

... More
4CX6sq.mm 2XWY

121

-

-

... More
Supply & end termination of following CU armoured power cables with necessary double compression brass glands, CU. terminal sockets, insulation tapes, fasteners, earthing clips & connecting the clip to main earth bus with suitable bare copper wire complete accessories as required; all outdoor double compression and indoor single compression

-

-

-

... More
1C X 185 sqmm Copper flexible cable

72

-

-

... More
1C X 150 sqmm Copper flexible cable

32

-

-

... More
1C X120 sqmm Copper flexible cable

1

-

-

... More
1C X95 sqmm Copper flexible cable

1

-

-

... More
1C X 25 sqmm Copper flexible cable

48

-

-

... More
1C X 16 sqmm Copper flexible cable

48

-

-

... More
1C X 10sqmm Copper flexible cable

48

-

-

... More
1C X 6sqmm Copper flexible cable

1

-

-

... More
4CX16sq.mm 2XWY

1

-

-

... More
4CX10sq.mm 2XWY

150

-

-

... More
4CX6sq.mm 2XWY

210

-

-

... More
FIRE SEALENT

-

-

-

... More
Supply and installation of Acrylic fire stop sealant CP606 or Approved Equivalent )with minimum 2 hours fire rating when tested in accordance with UL 1479 standards, shall be used along the periphery of ducts & chiller pipes without insulation passing through fire rated walls and floors made of concrete, masonry, metal, gypsum construction to provide up to 2 hours insulation and integrity when subject to the test conditions of UL 1479 standards. The product shall also be age tested as per DafStb guidelines. Sealant to provide sufficient MAF, water and gas tight seal apart from providing an airborne sound transmission reduction (STC of 50) and shall be tested as per DIN 52210 for sound insulation . The product should be tested for mold resistance rating of 0 as determined by ASTM G21-96 and should have a VOC content of approx. 75 g/l as per LEED 2009. The sealant shall be FM approved. All installations to be in full accordance with the manufacturer. The sealant should be tested in accordance with IEC 60068-2-57:1999-11 (Environmental Testing) as per Part 2-57: Test for Vibration-Time-history method and VERTEQII for seismic zone 4. The product shall bear the UL and FM approval logo on the packing where applicable. The rate shall include the mineral wool backing material and other miscellaneous items etc.., Assumed 15% Penetrants Ocupancy. Firestop installation should be done by HAFSC ( Accredated Firestop Speciality Contractor by providing complete installation report using CFS DM). Or using FIT (Firestop Installer Training) Program. As per IFC Guideliness EJ is recomended for non standard openings.-( supply & return air ducts.)

98

-

-

... More
ASSOCIATED CIVIL WORKS

-

-

-

... More
Pedestals : Providing & Laying of Reinforced cement concrete of M20 grade at the level given below, using river sand, 20 mm as down size coarse aggregates, application of necessary admixtures as specified by consultants inclding all leads and lifst, scaffolding wheever necessary, curing as directed, including the cost of shuttering, centering and staging for required height.

42

-

-

... More
Chipping, chassing & Plastering the wall openings in cement mortor 1:6 of 15 mm thick finishing to line and level with sand faced finshing at all levels, including all leads & lifts, scaffolding, curing etc complete

75

-

-

... More
BASMENET VENTILATION WORKS

-

-

-

... More
Exhaust air application - Normal Mode & Fire mode - Supply, installation, testing and commissioning of Exhaust air Vane axial flow fans. Fan construction shall include Pre-galvanized or Hot Dip Galvanized casing with minimum 220 GSM Zinc Coating, welded or casted propeller with aluminum airfoil blades, straightening vanes, universal mounting arrangement and Totally Enclosed Fan-Cooled (TEFC) motor. Motors shall be VFD rated with IE4 efficiency. Motor shall be suitable for 415V, 3 Phase, 50 Hz AC supply. Fans shall have minimum high temperature rating of 250°C for 2 hours with UL certification under Power Ventilators for Smoke-control Systems or valid European certification in accordance with EN12101-3. Fans shall be AMCA certified for Sound and Air Performance. Fans shall have a minimum Total efficiency of 70% Fan Sound Power level (LwA) shall be less than 92.5 dBA or Sound pressure level shall be 75 dBA @ 3 mtr under hemispherical reverberant room conditions Fans accessories: Fan Hood, Butter fly damper, Vibration isolators, Inlet/outlet guards, Silencers, Inlet Bell, Inspection section/door, Companian flanges ,fire rated canvas etc.

-

-

-

... More
26500 CFM @ 20 MM TOTAL STATIC with MS supports.

4

-

-

... More
22500 CFM @ 20 MM TOTAL STATIC with MS supports-

4

-

-

... More
FRESH AIR AXIAL FANS NORMAL & FIRE MODE - Supply, installation, testing and commissioning of Fresh air Vane axial flow fans. Fan construction shall include Pre-galvanized or Hot Dip Galvanized casing with minimum 220 GSM Zinc Coating, welded or casted propeller with aluminum airfoil blades, straightening vanes, universal mounting arrangement and Totally Enclosed Fan-Cooled (TEFC) or Totally Enclosed Air Over/Airtight (TEAO) motor. Motors shall be VFD rated with IE4 efficiency. Motor shall be suitable for 415V, 3 Phase, 50 Hz AC supply. Fans shall be AMCA certified for Sound and Air Performance. Fans shall have a minimum Total efficiency of 70% Fan Sound Power level (LwA) shall be less than 92.5 dBA or Sound pressure level shall be 75 dBA @ 3 mtr under hemispherical reverberant room conditions Fans accessories: Fan Hood, Butter fly damper, Vibration isolators, Inlet/outlet guards, Silencers, Inlet Bell, Inspection section/door, Companian flanges,fire rated canvas etc.

-

-

-

... More
26500 CFM @ 20 MM TOTAL STATIC with MS supports-

2

-

-

... More
22500 CFM @ 20 MM TOTAL STATIC with MS supports-

2

-

-

... More
JET FANS / CFD ANALYSIS / CO DETECTOR

-

-

-

... More
Supply, installation, testing & commissioning of dual speed induction Centrifugal type Jet ventilation fans long casing as per the specification. The entire assembly of fan shall be suitable to operate at fire mode condition to withstand the temperature of 300 deg C for Two hour & with totally enclosed Class-H insulated motor. . Motor shall be suitable for 415±10% volts, 50 Hz, 3 phase AC supply. The specified Jet fan quantity may be approximate now, the contractor to calculate the no. of fans required based on the CFD analysis.The quoted price shall include the cost of CFD analysis for normal / fire ( motor Reputed brand)

26

-

-

... More
CFD Analysis

1

-

-

... More
Supply,installation.testing,commissioning &Handing over of carbon monoxide sensors with sensing range from 25 to 50ppm

14

-

-

... More
Supply, installation, testing and commissioing of BASEMENT VENTILATION PANEL- Basement 1 & Basement 2 It should include starters for al items listed below. Qty and capacity of below items shall be considered as per acual motor ratign based on final selected model 1. Normal mode and fire mode exhaust fan - 2 No with space for VFD 2. Normal mode and fire mode fresh air fan -2 No with space for VFD 3. Jet fan starters (dual speed) 4. Jet fan PLC 5. Feeders for fire dampers with neccessary interlocks). Panel should give signal to jet fans to change the speed based on CO levels. (CO level - 0 - 25 ppm all jet fans should stop, CO level - 25 ppm to 75 ppm, jet fans should run in low speed + all normal mode fans should keep running till the CO level is brought down to less than 25 PPM) and once CO level goes beyond 75 ppm all jet fans and main exhaust fans should run at high speed) Main control Panel should be provided with necessary ancillary materials / AM switch / Push button sations, bus bars etc as per IS codes).Space for VFD to be provide in pannel. panel shall be provided with BMS compatibility through Modbus protocol.

4

-

-

... More
Fire survival Copper/Al. Cables inclusive of end termination

-

-

-

... More
Supply, installation, testing and commissioing of jet fans - 6c x 2.5 Sq.mm Armoured power cable.

2340

-

-

... More
Supply, installation, testing and commissioing of Exhaust fan cabling from panel to fan motors (suitable cable size as per motor requirement)

1560

-

-

... More
Supply, installation, testing and commissioing of CO Sensor - 3c x 1.0 Sq.mm Cu. power/control Cable for control/communication

2340

-

-

... More
Supply, installation, testing and commissioing of Signal from Fire panel to PLC- 2c x 1.0 Sqmm Cu. sheilded control cable

520

-

-

... More
Earthing

-

-

-

... More
Supply, installation, testing and commissioing of jet fans - GI Earth wire - 8 swg

700

-

-

... More
Supply, installation, testing and commissioing of Exhaust fans -GI Earthing strip – 25 X3mm

1000

-

-

... More
GI Hot dip Galvanized Ladder type Cable trays with suitable supports and all other accessories

-

-

-

... More
GI Hot Dip / Powder Coated 16 SWG Cable Tray with 600mm width and 50mm height

100

-

-

... More
GI Hot Dip / Powder Coated 16 SWG Cable Tray with 450mm width and 50mm height

300

-

-

... More
GI Hot Dip / Powder Coated 16 SWG Cable Tray with 300mm width and 50mm height

300

-

-

... More
GI Hot Dip / Powder Coated 16 SWG Cable Tray with 150mm width and 50mm height

500

-

-

... More
MS RELATED WORKS

-

-

-

... More
Supply,installation.testing of MS related works with nessarry supporting materials for Basement-01 & Basement-02

3000

-

-

... More
ASSOCIATED CIVIL WORKS

-

-

-

... More
Indoor Air quality testing (IAQ testing) for Parameter Such as VOC, CO2 and Bacteria Count After the installation of HVAC indoor units

1

-

-

... More
KITCHEN DRAINAGE WORKS

-

-

-

... More
Providing, fixing, jointing, testing and commissioning Hubless C.I. pipe for kitchen waste pipes installation conforming to IS:15905, stainless steel coupling with EPDM rubber as per DIN 19543, cut to required lengths including all necessary fittings and specials such as Bends, junctions, offsets, access pieces (plain or door) & vent cowl. Fixing at wall/ceiling level supported by galvanized steel clamps & hangers etc. duly epoxy coated.Cutting, chases/holes in floors / walls / slab with all necessary accessories as per specification/ drawings and directed by PMC/Employer. NOTE: HUBLESS C.I. PIPE TO SPUN / CENTRIFUGALY CAST CI PIPE ADAPTOR FLANGE TO BE PROVIDED

-

-

-

... More
Cost shall also be inclusive of painting the pipes & fittings with two coats of synthetic enamel paint of approved shade over a coat of primer.

-

-

-

... More
40 mm dia

40

-

-

... More
50 mm dia

40

-

-

... More
75 mm dia

100

-

-

... More
100 mm dia

100

-

-

... More
150 mm dia

10

-

-

... More
Providing, fixing, jointing, testing and commissioning of Spun / Centrifugaly cast CI pipe for kitchen waste installation conforming to IS:3989 to required layouts including all necessary fittings & specials such as bends, junctions offsets, access pieces. The pipes shall be running at ceiling suspended in basement area. Fixing at wall/ceiling level supported by galvanized steel clamps & hangers etc. duly epoxy coated.Cutting, chases/holes in floors / walls / slab with all necessary accessories as per specification/ drawings and directed by PMC/Employer. Ground floor toilet drainage and kitchen drainage.

-

-

-

... More
Cost shall also be inclusive of painting the pipes & fittings with two coats of synthetic enamel paint of approved shade over a coat of primer.

-

-

-

... More
75 mm dia

15

-

-

... More
100 mm dia

150

-

-

... More
150 mm dia

60

-

-

... More
200 mm dia

8

-

-

... More
Providing and fixing in position hubless CI full bore P trap confirming to IS 15905 including SS coupling with EPDM rubber as per DIN 19543 of the following sizes for underslab location including providing necessary galvanized steel support and as per Specification and duly epoxy coated. Cutting chase / hole in floors / slabs and bringing the same in proper condition and shape after placing the trap in right position complete by supporting by GI clamps / hangers as required with all necessary accessories as per specification/ drawings and directed by PMC/Employer

-

-

-

... More
100 mm inlet and 100 mm outlet

16

-

-

... More
Providing, fixing and testing C.I multi floor trap of self cleansing design with arm and provision for connection C.I /G.I pipe inlet fitting complete including cost of cutting and making good the walls and floors wherever required. Multifloor trap 75 mm outlet with 100 mm inlet

15

-

-

... More
Supply, installation and fixing testing and commissioning of Horizontal approved make electically operated storage Geysers / Water Heater inner container made from copper or stainless steel including the remal instalation safety valve, vacuum relief valve, neon lamp, mounting brackets, angle valve, connection hose installing in position with coach screws or bolts, nuts, testing, commissioning, etc, complete.

-

-

-

... More
Capacity 100 liters

5

-

-

... More
Providing and fixing heavy duty S.S. Floor Clean out with frame of approved design including setting in floor with cement motor to match with floor finish as directed by PMC/Employer. LOCATION: TOILETS

-

-

-

... More
Size 150 mm x 150 mm or 125 mm dia

15

-

-

... More
Providing and fixing heavy duty S.S. Floor grating with frame of approved design including setting in floor with cement motor to match with floor finish as directed by PMC/Employer.

-

-

-

... More
Size 150 mm x 150 mm or 125 mm dia

25

-

-

... More
INTELLIGENT FIRE ALARM SYSTEM

-

-

-

... More
Supplying, installation, testing & commissioning of micro processor based Intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories. The panel shall be compatible for IBMS system with open protocol Modbus over IP complete as per specifications. Ten Loop Panel

3

-

-

... More
DVC (Digital Voice Command) system for fire fighters telephone. Supplying, installing, testing and commissioning of Digital Voice Command Extended Memory and Keypad. The DVC Should support 2 ways Communication for Fire Fighters.The Fire Fighters Telephone System shall be capable of having minimum 30 Telephones in conference in multiple FFT Risers. This has to be installed in one of the above 10 loop fire alarm panel. This inclusive of necessasy accessories, amplifiers (suitable for fire fighters telephone quantity mentioned in this BOQ), modules & should be seamless integration with all fire alarm panels. This should be the same make of main fire alarm panel. Vendor shall consider the suitable size cabinet of fire alarm panel to accomodate this DVC equipments

1

-

-

... More
Supplying, installation, testing and commissioning of Central Graphical fire alarm management system to centrally monitor and operate the fire alarm system complete as required

2

-

-

... More
Supplying, installation, testing and commissioning of Addressable Active Repeater Panel consists of display board having 160 Character Display with Touch key pad, Mother board which will have 64 Bit Processor, Inbuilt RS-485 Networking Circuit for peer to peer networking.

1

-

-

... More
Supplying, installation, testing and commissioning of intelligent analog addressable Addressable Detectors - Multi Sensor - Heat Cum Smoke detector with base with Binary coded address setting / Rotary Switches / Electronic codec programable address setting. Dual LED’s for 360° visibility complete with mounting base complete as required, with Back box, Glands

1594

-

-

... More
Supplying, installation, testing and commissioning of Response indicator for all detectors located above false ceiling / Below False Floor complete with all connections etc as required with Back box, Glands

271

-

-

... More
Supplying, installation, testing and commissioning of Fault Isolator Module capable of monitoring shorted loop circuit and automatically restore communications as required with Back box, Glands

151

-

-

... More
Supplying, installation, testing and commissioning of intelligent addressable Addressable Heat Detector / Thermal Detector with base with Binary coded address setting / Rotary Switches / Electronic codec programable address setting. Dual LED’s for 360° visibility complete with base as required Back Box, Glands

581

-

-

... More
Supplying, installation, testing and commissioning of addressable Fire Control Module / Control Relay Module for AHU / CSU / HRW / TFA Tripping, Access Control Door Tripping, Smoke Exhaust Fan activation, Fire Damper Activation / PA System Activation etc complete as required with back Box, Glands

238

-

-

... More
Supplying, installation, testing and commissioning of addressable Firefigher Phone Control Module for Firefighter Telephone Jack to activate the Firefighter Telephone functional, complete as required

30

-

-

... More
Supplying, installation, testing and commissioning of intelligent Addressable Beam Detector with Short Circuit Isolator (inbuilt or separate) complete with emitter and received including connections with remote test features etc complete as required with back box, Glands. The rate shall inclusive of Response Indicator. Also the rate shall inclusive of External dedicated 24VDC Power Supply Unit with Battery backup in case the Beam Detector shall not have loop pwered. Power Supply Unit shall be provided with necessary Enclosures.

4

-

-

... More
Supplying, installation, testing and commissioning of Intelligent Addressable Duct Detector including suitable Photo detector complete with base as required with back box , Glands

107

-

-

... More
Supplying, installation, testing and commissioning of Intelligent Addressable Manual Pull Station Dual Action type, complete as required with back Box, Glands.

116

-

-

... More
Supplying, installation, testing and commissioning of addressable horn cum strobe complete as required with Back Box, Glands

186

-

-

... More
Supplying, installation, testing and commissioning offire fighter telephone handset complete as required Back Box, Glands

30

-

-

... More
Supplying, installation, testing and commissioning of intelligent interface unit Modbus protocol i.e. supplying communicatiob links between building management system and fire alarm control panel complete as required.

1

-

-

... More
Supplying, installation, testing and commissioning of fire fighter telephone jack complete as required.

30

-

-

... More
Supply and laying of FRLS PVC insulated 2 core 1.5 sq.mm. Armoured Copper Cable on ceiling / wall using fixing accessories like screws, plug, clamps, etc., as per standard methods and as directed by the Departmental Officers.

35476

-

-

... More
Supply, installation, fixing, testing and commissioning of Analogue Addressable Monitor module with back box (1.6mm thick RED colour) operating at 24V DC, 2A, rated at 230V, provided withSPDT contact with required fixing accessories

200

-

-

... More
Supply and installation of MS Powder coated Trunking 300 x 50 mm x 1.6mm with cover & fixing suppports etc as required (Cable dressing for Fire & PA panel)

50

-

-

... More
Supply and installation, testing and commissioning of Power Supply Unit for hooters (inclusive of Battery ckt & shall have inbuilt charger circuit, 2x12V 7.1AH Battery and enclosure)

14

-

-

... More
Supply, installation, testing and commissioning of Client workstation Intel core 9th Generation Intel Core i9 Processor by latest generation or better, 16GB DDR3 RAM, 64-bit operating system, 1TB SSD for OS and Security Center applications, with a minimum of 16 GB of free disk space to install the Security Center client application, 1TB SATA Hard disk with 7200rpm, GbE network interface card, DVD-RW standard keyboard & Mouse with Dual NVIDIA® GeForce® RTX 2080 video card with 21" FULL HD LED MONITOR. Minimum 4 HDMI,1 parallel, 8 USB 2.0, 1 serial, 2 Ultra ATA/100, 2optional IEEE1394, 1 USB Keyboard, 1 USB Mouse, 1 video, 1 Microphone jack, 1 Line-in jack, 2 x 1GBPS RJ-45 Interface Port (Note: The Configuration mentioned is only Minimum requirement. Vendor shall be consider as per the Fire Alarm System OEM recommendations, in case of higher configurations shall be required to enable the functional requirements and consider the cost for the same & quote accordingly. Bidder shall be considered the specified configuration if the Fire Alarm System OEM do not have an objection. No deviation shall be accepeted.)

2

-

-

... More
ASPIRATION SMOKE DETECTION SYSTEM

-

-

-

... More
Supplying, installation, testing & commissioning of intelligent aspiration detector for area coverage of minimum 5000 sq.ft complete as required.

2

-

-

... More
Supply, installation, testing and commissioning of Electronic Hooter / Sounder providing on wall using fixing accessories like screws, plug, clamps and etc., as per standard methods and as directed by the Departmental Officers

2

-

-

... More
Supply, Installation, testing, commissioning of 25 mm outer dia CPVC Pipe with end caps including making air sampling opening of appropriate dia on appropriate interval and all accessories as required, (rate for area protected in sq.m)

64

-

-

... More
WATER LEAK DETECTION SYSTEM

-

-

-

... More
Supplying, installation, testing and commissioning of Water Leak Detection sensing cables with end of line connectors along with Hold-down clips at every 0.3M interval.

50

-

-

... More
Supplying, installation, testing and commissioning of Addressable Water leak detection panel including battery backup (12 hr) as per the below specification inclusive of all necessary accessories - Inbuilt with Modbus for BMS integration - Relay output for Alarm and fault - 230V AC 5A - LED Indications (power ON, Alarm, fault etc) - 100 event log - Wall mount type with enclosure and PSU with battery backup

1

-

-

... More
Supplying, installation, testing and commissioning of Water Leak Detection Module Water leak tape interface module with display, enclosure, PSU with battery backup and alarm out for Hooter, relay out for fire integration as per specification

2

-

-

... More
Supply, installation, testing and commissioning of Electronic Hooter / Sounder providing on wall using fixing accessories like screws, plug, clamps and etc., as per standard methods and as directed by the Departmental Officers

2

-

-

... More
RODENT REPELLENT SYSTEM

-

-

-

... More
Supplying, installation, testing and commissioning of Master Console panel including support bracket (12 TRANSDUCER PER CONSOLE) with modbus for BMS integration

6

-

-

... More
Supply, installation, testing & commissioning of transducers, circular ceiling mounted type, having power output of 800mW/transducer. Quoted rate shall include necessary mounting clips / clamps, MS back box etc. vide technical specification and with a coverage area of ceiling/ floor void- 150 sq.ft. Room void – 300 sq.ft respectively.

62

-

-

... More
Supplying, installation, testing and commissioning of 1 pair flexible 14/40 SWG Specially coated wire, PVC sheathed Cable

530

-

-

... More
Supplying and fixing of following sizes of steel conduit along with accessories in surface / recess including painting in case of surface conduit or cutting the wall and making good the same in case of recessed conduit as required 25 mm

530

-

-

... More
IP BASED PUBLIC ADDRESS SYSTEM

-

-

-

... More
Supply, installation, testing, and commissioning of Ceiling Mount Loud Speakers with EN 54-24 or UL Certified, suitable for fire detection, fire alarm, and fire-protected signalling systems. Power: 9W or better Rated Power: 6W or better Power Tapping: 6/3/1.5W or better SPL: 98dB (Avg), 104dB (Peak) or Better Effective Frequency Response: 68 Hz to 20 kHz (-10 dB) Sensitivity (1W/1m): 85dB or better Dispersion: 180° Note: The rate shall inclusive of back box for True Ceiling Speaker wherever applicable. The Quantification of the True Ceiling Speaker as per the tender drawing.

504

-

-

... More
Supply , Installation, Testing & Commissioning of Wall Mount Loud Speaker with EN 54 or UL Certified, having the following specifications : Surface / Wall mount speaker with Driver : ~ 4" Polypropylene Woofer, ~ 1" Ferrofluid Cooled Dome Tweeter Power 9W or Better Rated Power: 6 Watts or better Sensitivity: 88dB or better Power Tapping: 6/3/1.5W or better Effective frequency range(-10 dB) :15 Hz to 16KHz or better Dispersion : 90° x 90° UV-resistant PC / ABS, Injection Molded, Weatherproof Enclosure, Note: The rate shall inclusive weather proof cabinet for Cafeteria wall mount 6W Speaker. The Quantification of the weather proof speakers as per the tender drawing.

210

-

-

... More
Supply , Installation, Testing & Commissioning of 15W or better Two-Way Compact / coaxial / Full-Range Speaker meeting EN 54 or UL Certification with following specifications and as directed by Engineer In Charge. Driver Size: ~ 1 x 4" LF & 1 x 0.79" HF Driver or better Maximum SPL: RMS - 98dB or better Sensitivity: 84dB or better Frequency Response 115Hz – 16kHz (±5dB) or better Dispersion: 110 degrees conical or better Weateherproof and The Speaker should pass 100HR Salt Spray Test Per ASTM B11, UL-1480, CE Enclosure: ABS Aluminium, Painted grille Included Accessories: Mounting bracket with other neccessary accessories to make system complete as per specification/drawings

89

-

-

... More
Supply , Installation, Testing & Commissioning of EN-54 certified or UL Listed 16 Zone, IP Digital Voice Alarm Network Controller in future. redundant IP connnection, redundant power supply unit built with following features. a. Voice alarm controller should be able to connect directly over Ethernet & have display. It should have functions like audio playing, zone control, fault monitoring, log recording, volume control and amplifier switchover. b. Built in DSP with 10 band parametric EQ for each output c. Can handle dynamic requests for live pages, delayed pages, Digital Record and Playback (DRP), prerecorded messages (simple and assembled), and mute actions d.Rate shall inclusive of Battery backup @ 24hrs normal operation and 30minutes alarm operation e. Overall Fault Indicator system fault & Power fault, Alert Tone Silence Button, Announce/Alarm Indicator , Disabled /Delayed Zones Indicator and Zone delay control. f.Internal storage available for over 1000 minutes of message audio. g.The controller shall have inbuilt 16 Zone. If the OEM desn't have inbuilt 16 Zone circuit, additional Zone extender shall be considered within this cost itself. There is no additional BoQ / Cost shall be provided. h. It can supports 16 Paging stations or more

1

-

-

... More
SITC of EN-54 certified Touch Screen Digital Communications Station with Goosneck microphone and which can support Handheld, Surface (Flat) or Desktop (Free Standing) Versions. - Connects to call station interface via CAT-5 cable or IP Configurable, - Redundant Ethernet Ports, - PoE Powered, - Suitable for use as the Emergency Microphone Paging Station in EN54-16 Systems or equivalent

3

-

-

... More
Supply, installation, testing & commissioning of EN 54 or UL Certified IP Networked Dual Channel Amplifier with following feautures. a. Power Output: 2 x 500W or better @ 70.7V / 100V / 8Ω / 4Ω b. Amp Topology: Class D c. Frequency Response: 20Hz - 20kHz d. THD: 0.15% e. Signal To Noise Ratio: 85dB (A-Weighted) f. Thet total Amplifier quantity shall be flexible and can be choosen by OEM as per their amplifier configuration and has to ensure meeting the total wattage requirement of the Speakers. g. Connecting laod shall be 20% spare on each channel.

4

-

-

... More
Supply, installation, testing & commissioning of EN-54 or UL certified IP Networked Single / Dual Channel Amplifier with following feautures. a. Power Output: 1 x 500W or 2 x 300W or better @ 70.7V / 100V / 8Ω / 4Ω b. Amp Topology: Class D c. Frequency Response: 20Hz - 20kHz d. THD: 0.15% e. Signal To Noise Ratio: 85dB (A-Weighted) f. Thet total Amplifier quantity shall be flexible and can be choosen by OEM as per their amplifier configuration and has to ensure meeting the total wattage requirement of the Speakers. g. Connecting laod shall be 20% spare on each channel.

10

-

-

... More
Supply, installation, testing & commissioning of emergency power supply manager allows the permanent emergency power supply in accordance with EN 54-4 certified, in the event of a power failure. The 19” unit (2U) is equipped with 6 fused outputs that can be used with up to 30 A load. The smart battery condition monitoring ensures an uninterrupted 24 V DC power supply and the recharging of the battery immediately after the restoration of the mains supply. Due to the “hot swap” technology the exchange of the batteries can be done without service interruption.

5

-

-

... More
Supply, installation, testing and commissioning of System Management software with following function: Alarm, prerecorded and live messages. a. Music broadcasting. b. Management of speaker zones. c. Microphone desks connected by bus or through the corporate data network. d. Reception of 4 simultaneous digital audio channels via IP connection. e. Output/input contacts for emergency functions, message activation, zone control f. Audio outputs with individual volume control. g. Critical path supervision: speaker lines, amplifiers, cards, power, contacts, prerecorded messages h. Call point software for live or prerecorded messages, alarm notification i. PC integration and direct integrations (XML,API/DLL). j. Control data reception and transmission via IP connection. k. Linked systems through corporate network andaccessible from IP points (microphones) l. Double Ethernet connection and double power supply input for redundant installation

1

-

-

... More
Supply, installation, testing and commissioning of Client workstation Intel core 9th Generation Intel Core i9 Processor by latest generation or better, 16GB DDR3 RAM, 64-bit operating system, 1TB SSD for OS and Security Center applications, with a minimum of 16 GB of free disk space to install the Security Center client application, 1TB SATA Hard disk with 7200rpm, GbE network interface card, DVD-RW standard keyboard & Mouse with Dual NVIDIA® GeForce® RTX 2080 video card with 21" FULL HD LED MONITOR. Minimum 4 HDMI,1 parallel, 8 USB 2.0, 1 serial, 2 Ultra ATA/100, 2optional IEEE1394, 1 USB Keyboard, 1 USB Mouse, 1 video, 1 Microphone jack, 1 Line-in jack, 2 x 1GBPS RJ-45 Interface Port (Note: The Configuration mentioned is only Minimum requirement. Vendor shall be consider as per the Public Address System OEM recommendations, in case of higher configurations shall be required to enable the functional requirements and consider the cost for the same & quote accordingly. Bidder shall be considered the specified configuration if the Public Address System OEM do not have an objection. No deviation shall be accepeted.)

1

-

-

... More
Supplying, installation, testing and commissioning of Volume controller to be choosen max control of 20W for one speaker (near call station)

15

-

-

... More
Supplying, installation, testing and commissioning Rack Mounted Multimedia Player as per specifications

1

-

-

... More
Supply and laying of FRLS PVC insulated 2 core 1.5 sq.mm. Armoured Copper Cable on ceiling / wall using fixing accessories like screws, plug, clamps, etc., as per standard methods and as directed by the Departmental Officers.

10619

-

-

... More
SECURITY ACCESS CONTROL SYSTEM

-

-

-

... More
Supply, Installation, Testing, Commissioning of the Linux based IP intelligent master controller, directly connects upto 2 doors, Controller should directly connect either 2 readers in Weigand or 4 readers on OSDP. IP controller should support upto 64 readers and Doors with reader expansion module. Controller should have 8 inputs and 4 outputs natively and should have the capability to expand upto 500 inputs and 500 outputs with the support of expansion module. IP controller should have the capacity of 2,40,000 Cardholder capacity and 50,000 Transaction buffer. Controller should support dual IP connectivity using adaptor. The intelligent controller should provide a robust network security such as mutual authentication with using TLS 1.2 while running in an FIPS 140-2 approved operating environment. The intelligent controller should provide an enhance security with AES 256 encryption with Expansion modules. The networked door controller shall not be a proprietary product of the manufacturer of the host access control software application, and must have the ability to migrate to an alternative manufacturer’s host access control software application by remote reconfiguration or firmware upgrade and without intervention from the original controller manufacturer. Should support atleast 8 card formats offline, 255 access level per Card Holder, Anti-Passback, Elevator support, Turnstile and Biometric device Support (centralized biometric tempate management), paired and alternate reader feature, support multi-occupancy Rules, Should support 19 Digit (64 bit )Card format. Should have intrusion alarm functions like Entry/Exit delays, Area monitoring, Standard Alarm Masking etc. Should support wireless lock integration, Power supply alerts and events, Product Compliance : UL-294 recognized, NIST certified encryption, FCC part 15 Calss A, RoHS, CE compliant, Supply with all necessary power supply, battery back-up and Enclosure.

14

-

-

... More
Supply, Installation, Testing, Commissioning of the 4 Reader Module that shall control two physical barriers/locks and up to four (using OSDP) or two (using Wiegand) readers. The peripheral interface device shall be able to utilize a cryptographic module that can encrypt/decrypt communication with the intelligent controller, supporting AES encryption using a minimum 256 bit key length. SHould have Eight unsupervised/supervised inputs (including tamper, AC fail & Battery input) and four relay outputs. Product compliance with FCC,UL-294,IEC 62368-1 and RoHS. Supply with all necessary power supply, battery back-up and Enclosure. The Quantity of Reader Modules are mentioned in the BoQ as per the requirement of project. Readers & Reader Modules must works under OSDP Protocol. Contractor shall slect the product accordingly as per the approved makelist.

75

-

-

... More
Supply, installation, testing & commissioning of Multi-Technology contactless smart card reader, Mullion mount, IP65, Converge multiple credential technologies onto one reader platform with support for Smart and Mobile credentials, Bluetooth, OSDP, encrypted communication between credential and reader, supports Secure Identity Object on Seos, iClass SE/SR, Mifare DESFire EV2/Ev3 and Mifare Classic , Certification: UL 294/cUL, FCC certification CE including RoHS II,BIS, EAL 5+ certified secure with 2.5mm thick SS front plate as per specification suitable for mounting on metal surface/metal frames or wooden frames wall or as required based on site conditions including all accessories. UL Certified.

264

-

-

... More
Supply, installation, testing & commissioning of Supply, installation, testing and commissioning of Biometric Finger Reader with multi spectral imaging technology for consistent read performance,IP67, supports Secure Identity Object on Seos, iClass SE/SR, Mifare DESFire EV2/Ev3 and Mifare Classic, BLE and NFC mobile ID's, support 5000 finger print on device, should support 1:N and template on card 1:1,should support OSDP and Weigand communication, Certification: BIS, UL 294/cUL, FCC certification, CE,, EAL 4+ certified secure element with all accessories required at site to complete the work as per technical specification with 2.5mm thick SS front plate as per specification suitable for mounting on metal surface/metal frames or wooden frames wall or as required based on site conditions including all accessories. UL Certified.

18

-

-

... More
Supply, installation, testing & commissioning of Supply, installation, testing and commissioning of QR Code Reader as per the technical specification. The QR Code reader shall install inside the Swing Barrier for Visitor QR Code Access. QR Code Reader OEM shall co-ordinate with Swing Barrier OEM and provide thenecessary provisions to mount the device accordingly.

4

-

-

... More
Supply, installation, testing and commissioning of 8K contactless smart card support 13.56 Mhz, support multi-layered trusted management of secure identities using the portable Secure Identity Object data model, supports AES 128 bit cryptographic algorithm for data protection, printable cards with corporate 1000 programming to avoid duplication.with Lanyard to hold the cards as per specification.

1000

-

-

... More
Supply,Installation, Testing and Commssioining of truely 64 bit, web based Access Control System Server Software consisting of Access Control system for 512 reader license, 10 client License, Graphical layout. All these along with high end security features like Global & anti-pass back, interfacing with CCTV integration, paging & Email interface, Guard tour, visitor management consist in single package as per specification. The Security Management System shall utilize the Microsoft SQL database for applications with one to four users and up to 5000 controlled doors, expandablity of memory shoule be available for future expansion. The Security Management System shall operate in Windows server 2016 or latest windows operating system as the host operating system. This software should have Time & Attendance Software with necessary reports as per client requirement incl. of customization as per the tender specifications Access control Software having features like Web Based Client for Badging, Reporting, Alarm and Event. The application should provide dynamic web dash board for system parameters and health status information. Server support including Windows® Server 2016 or latest, SQL Server 2012/ 2014/ 2016, Windows 10 - 64 bit for client computers. Single user interface for multiple security and business functions , Certification Management Virtualization support for VMWare and Microsoft® Hyper-V, Database partitioning , definable operator permissions ,Support for cloud deployment. Note: a. Access Control Software shall have inbuilt module of Visitor Management System Software with 3 Client Workstation licenses. b. The software shall be complied as per the requirement mentioned in the Tender specifications. Deviation will not be accepted, if any deviation shall be taken up from Tender Technical Specifications. c. Software and its licence cost shall inclusive Reader Licences, Main + Redundancy Server and Client User Licenses. There is no additional cost shall be provided by Employer.

1

-

-

... More
Supply, installation, testing and commissioning of ACS Server machine : Includes Server, Windows Server Standard, SQL Server Standard. Intel Xeon Silver 3104 Processor, 8 MB L3 Cache, 6 Cores, 6 Threads 3 x 8GB RDIMM, 2666MT/s 1 x 1TB 10K RPM SAS 2.5in Hot-plug Hard Drive 2GB Network Card Windows Server 2016/2019 Standard , 104, 12 function key DD, 21" LCD Monitor, Wireless Mouse, USB Keyboard, CD/DVD Combo Writer, TCP/IP Connection. (Note: The Configuration mentioned is only Minimum requirement. Vendor to consider as per OEM recommendations in case of higher configurations shall be required as per project functional requirements and the bidder to consider the cost for the same & quote accordingly. The bidder needs to consider the same configuration if OEM will not have an objection for the mentioned specifications. No deviation shall be accepeted.) The ACS Server shall be Hot Redundant 1+1 Configuration. This Line item Rate / Cost shall inclusive redundancy server also. No Additional Cost shall be paid for Redundancy Server. The Server shall be Balde Type and its should be Rack mounted. Tower type shall not be accepted

1

-

-

... More
Supply, installation, testing and commissioning of Client workstation (Access Control System Client Workstation) Intel core 9th Generation Intel Core i9 Processor by latest generation or better, 16GB DDR3 RAM, 64-bit operating system, 1TB SSD for OS and Security Center applications, with a minimum of 16 GB of free disk space to install the Security Center client application, 1TB SATA Hard disk with 7200rpm, GbE network interface card, DVD-RW standard keyboard & Mouse with Dual NVIDIA® GeForce® RTX 2080 video card with 21" FULL HD LED MONITOR. Minimum 4 HDMI,1 parallel, 8 USB 2.0, 1 serial, 2 Ultra ATA/100, 2optional IEEE1394, 1 USB Keyboard, 1 USB Mouse, 1 video, 1 Microphone jack, 1 Line-in jack, 2 x 1GBPS RJ-45 Interface Port (Note: The Configuration mentioned is only Minimum requirement. Vendor shall be consider as per the Access Control System Software OEM recommendations, in case of higher configurations shall be required to enable the functional requirements and consider the cost for the same & quote accordingly. Bidder shall be considered the specified configuration if theAccess Control System Software OEM do not have an objection. No deviation shall be accepeted.)

2

-

-

... More
Supply, installation, testing and commissioning of Client workstation (Visitor Management System) Intel core 9th Generation Intel Core i9 Processor by latest generation or better, 16GB DDR3 RAM, 64-bit operating system, 1TB SSD for OS and Security Center applications, with a minimum of 16 GB of free disk space to install the Security Center client application, 1TB SATA Hard disk with 7200rpm, GbE network interface card, DVD-RW standard keyboard & Mouse with Dual NVIDIA® GeForce® RTX 2080 video card with 21" FULL HD LED MONITOR. Minimum 4 HDMI,1 parallel, 8 USB 2.0, 1 serial, 2 Ultra ATA/100, 2optional IEEE1394, 1 USB Keyboard, 1 USB Mouse, 1 video, 1 Microphone jack, 1 Line-in jack, 2 x 1GBPS RJ-45 Interface Port (Note: The Configuration mentioned is only Minimum requirement. Vendor shall be consider as per the Visitor Management System Software OEM recommendations, in case of higher configurations shall be required to enable the functional requirements and consider the cost for the same & quote accordingly. Bidder shall be considered the specified configuration if the Visitor Management System Software OEM do not have an objection. No deviation shall be accepeted.)

4

-

-

... More
Supplying, installation, testing and commissioning of Single Leaf EM Lock 600LBS in each Leaf Electromagnetic Lock with required mounting brackets for single door as per the tender specifications

25

-

-

... More
Supplying, installation, testing and commissioning of Double Leaf EM Lock 600LBS in each Leaf Electromagnetic Lock with required mounting brackets for double door as per the tender specifications

111

-

-

... More
Supplying, installation, testing and commissioning of surface / flush mounted (as required at site) Magnetic Contact (Door position sensor) for access controlled doors as per the tender specifications

307

-

-

... More
Supplying, installation, testing and commissioning of Local scare alarm with required wiring between LSA & door contacts (For fire exit doors). Rate shall inclusive of door contacts

30

-

-

... More
Supplying, installation, testing and commissioning of panic bar for fire exit doors (double leaf) as per Specification (For fire exit doors, Panic BAR shall be RED in color).

30

-

-

... More
Supplying, installation, testing and commissioning of 4 core 1.0 Sq mm Un Armoured Shielded, Multistanded Copper Conductor, PVC sheathed Cable with accessories for connecting controller to Lock & door position sensors, Buzzer,BGU,Pushbutton as per the tender specifications

16045

-

-

... More
Supplying, installation, testing and commissioning of 2 core x 1 Sq mm Un Armoured Shielded, Multistanded Copper Conductor, PVC sheathed Cable with accessories

10344

-

-

... More
Supplying, installation, testing and commissioning of Buzzer for access controlled doors as specified in the Tender Specifications

138

-

-

... More
Supplying, installation, testing and commissioning of EDR (Emergency Door Release)

138

-

-

... More
Supplying, installation, testing and commissioning of Egress Switch Units with back box and accessories

3

-

-

... More
Supplying, installation, testing and commissioning of MS Powder coated Trunking 300 x 50 mm x 2mm with cover & fixing suppports etc as required for panel dressing

270

-

-

... More
Supplying and fixing of following sizes of Medium Class PVC conduit along with accessories in surface / recess including cutting the wall and making good the same in case recessed conduit as required 25mm PVC Conduit.

19799

-

-

... More
Supplying, installation, testing and commissioning of X-Ray Single Generator Indoor Bagage Scanner with following technical parameters. Tunnel Size: Min 600 mm (W) x 400 mm (H) or Better, Dimensions: Length: Min 2000 mm or Better, Height: Max 1300 mm or Better. Single view of 160KV high energy XBS which provides steel penetration of 34mm Steel block and wire resolution of 38-AWG. 2 built-in Full HD cameras which helps to monitor the Tunnel Entry & Exit. Software with Inbuilt Artificial Intelligence tool that has 24 types of items to display the Scanned images with AI overlay. Single Screen that displays both Scanned images and video surveillance of Fisheye camera simultaneously. Complete with 0.5 meter Discharge SS Tables with dedicated computer for Monitoring, Image storage and archiving with necessary software. Along With Dual Core Processor at min 3.6 GHz, 8GB RAM, 4TB Harddisk, With Wired Mouse & Customised Keyboard with Emergency stop function, Linux OS and CMS to be incorporated for Centralised monitoring at the premises. Min 1 million images storage along with video recording of Full HD camera, Threat image protection (TIP) enabled in the software with 100 knives, 100 explosives, 100 guns to be loaded in the TIP library which enables the operator to active during security check. HIT, MISS & FALSE Alarm features must be included with different colour code as Green for HIT, Red for MISS and Yellow for FALSE alarm to be enabled in the software. Daily reports to be generated for TIP along with date, time, screener particulars and number of bags screened. Should comply with NABL, CE, FDA, ROHS, FCC, ISO, QCI, NSIC, BS EN 60204-1:2018, EN 61000-6-2-2005, EN 61000-6-3:2007, EN ISO 12100:2010

1

-

-

... More
Supplying, installation, testing and commissioning of Door frame metal detector (DFMD) with Dual side detection, 18 overlapping detector Multi-zones, Displaying panel, Indication of alarm areas, Adjustable area of sensitivity, Two Way operation, Static counting (Directional Counter - In, Out, Net and Alarm), Battery backup 6 to 8 hours. Shall be compatible to integrate with Barriers. Should comply with NABL, CE, FDA, ROHS, FCC, ISO, QCI, NSIC, BS EN 60204-1:2018, EN 61000-6-2-2005, EN 61000-6-3:2007, EN ISO 12100:2010

2

-

-

... More
Supplying, installation, testing and commissioning of High Speed Swing Barrier of (4+1) lane configuration, flaps made of transparent acrylic with 10 mm thickness, RGB indication, Clear passageway, Indoor, opening / closing time of 0.2 seconds minimum. The housing and the base columns shall be made of SS304 with semigloss smooth finish. The barrier shall be equipped with Servo motor and controlled in both directions. In the event of a power failure, both directions shall be freely accessed, Automatic reset upon resumption of power supply. The dimensions shall be 100mm width, 1400mm length, 1000mm height and the passage width of 600mm for Normal lane & 900mm for wide lane. The MCBF shall be above 10 million cycles with built-in card reader mounting, power supply module, wiring & necessary components. Compatible for Integration with Access control & CCTV system. Should comply with NABL, CE, FDA, ROHS, FCC, ISO, QCI, NSIC, BS EN 60204-1:2018, EN 61000-6-2-2005, EN 61000-6-3:2007, EN ISO 12100:2010

2

-

-

... More
Supply, Installation, Testing and Commissioning of Boom Barrier of 3 meter wide with power supply and necessary manual control components. Barrier should operate with 24V Servo motor and MCBF not less than 10 million cycles. Shall be suitable to control through access control system & Compatible for Integration with CCTV System, Perimeter security system. Barrier arm with LED light and Red reflective strips and to provide accessories such as Wireless remote, Push button, Loop detector, Dual eye Photocell, light with buzzer and boom resting post. Should comply with NABL, CE, FDA, ROHS, FCC, ISO, QCI, NSIC, BS EN 60204-1:2018, EN 61000-6-2-2005, EN 61000-6-3:2007, EN ISO 12100:2010

4

-

-

... More
Supply, Installation, Testing and Commissioning of Boom Barrier of 1.5 meter wide with power supply and necessary manual control components. Barrier should operate with 24V Servo motor and MCBF not less than 10 million cycles. Shall be suitable to control through access control system & Compatible for Integration with CCTV System, Perimeter security system. Barrier arm with LED light and Red reflective strips and to provide accessories such as Wireless remote, Push button, Loop detector, Dual eye Photocell, light with buzzer and boom resting post. Should comply with NABL, CE, FDA, ROHS, FCC, ISO, QCI, NSIC, BS EN 60204-1:2018, EN 61000-6-2-2005, EN 61000-6-3:2007, EN ISO 12100:2010

2

-

-

... More
CAR PARKING GUIDANCE & MANAGEMENT SYSTEM

-

-

-

... More
Long range reader Supply , Installation, Testing & Commissioning of UHF based RFID long range (6 mtr) readers are used for 2 wheeler & 4 wheeler vehicle access control, identification and authentication applications. Seamlessly integrates with Wiegand/RS232 compatible controllers to drive vehicle entrance automation equipment such as Boom Barriers. The readers identify & authenticate vehicles passing through entry/exit points of a facility, parking lots, etc. from a long distance. Rate shall inclusive of SS304 finish fabricated mounting accessories

6

-

-

... More
Supply, Installation, Testing and Commissioning of ASSA Flex Tamper Proof RFID Tags for 4 wheeler should be compatible with the Long Range Reader

227

-

-

... More
Supply, Installation, Testing and Commissioning of ASSA Flex Tamper Proof RFID Headlight Tags for 2 wheeler should be compatible with the Long Range Reader

1045

-

-

... More
Supply, Installation, Testing & Commissioning of Combo device of Ultrasound Detector & LED Indicator (Red / Green): To sense the vehicle occupancy with automatic detection. Ultrasonic detection sensing with RS485 as communication protocol, detectable range of 0.3m to 4.5m, Scope of detection: 15 deg, Operating temp:-20 to +60 Degree celcius. LED indicator should have common anode double color light design. The unit should have single module with standard baud rate & housing material with all required mounting connectors, enclosure & Accessories.

30

-

-

... More
Supply , Installation, Testing & Commissioning of ZONE CONTROLLER: Equipped with communication protocol: RS485, with Standard Baud rate, Maximum load quantity 28 loads , Minimum Communication distance: 400 mtrs, Working temp range: 5 deg C to 50 deg C. The above shall be housed in a vandal proof & secure PVC Cabinets to be supplied along with the Controllers and its necessary accessories.

2

-

-

... More
Supply , Installation, Testing & Commissioning of FLOOR CONTROLLER: Operating voltage :AC220V± 10%, Communication protocol : RS485, with Standard Baud rate &The above shall be housed in a vandal proof & secure PVC Cabinets to be supplied along with the Controllers and its necessary accessories.

1

-

-

... More
Supply , Installation, Testing & Commissioning of Informatory Signs Boards Main Display at Entry Gate Of Building : 1 ROWS LED DISPLAY (For indicating total vacant slots at respective level).(Installation of the said display unit is at entrance of main gate) Height 6 inch, Letter 5 mm ultra bright LED Matrix, Every line will have seperate address in case of multiple lines, Communication through TCP-IP/RS 485, Out door display with weatherproof enclosure, MS Powder coated Panel with all required accessories for mounting, Power Supply - 230VAC

1

-

-

... More
Supply , Installation, Testing & Commissioning of Parking management & Parking Guidance Software for all nodes with required license

1

-

-

... More
Supply, installation, testing and commissioning of Client workstation Intel core 9th Generation Intel Core i9 Processor by latest generation or better, 16GB DDR3 RAM, 64-bit operating system, 1TB SSD for OS and Security Center applications, with a minimum of 16 GB of free disk space to install the Security Center client application, 1TB SATA Hard disk with 7200rpm, GbE network interface card, DVD-RW standard keyboard & Mouse with Dual NVIDIA® GeForce® RTX 2080 video card with 21" FULL HD LED MONITOR. Minimum 4 HDMI,1 parallel, 8 USB 2.0, 1 serial, 2 Ultra ATA/100, 2optional IEEE1394, 1 USB Keyboard, 1 USB Mouse, 1 video, 1 Microphone jack, 1 Line-in jack, 2 x 1GBPS RJ-45 Interface Port (Note: The Configuration mentioned is only Minimum requirement. Vendor shall be consider as per the Parking Guidance System Software OEM recommendations, in case of higher configurations shall be required to enable the functional requirements and consider the cost for the same & quote accordingly. Bidder shall be considered the specified configuration if the Parking Guidance System Software OEM do not have an objection. No deviation shall be accepeted.)

1

-

-

... More
Supply & laying of 4C x 1 sq mm Flexible Multistrand cable for signal / power as per specification. (from Sensor to sensor & controller) in PVC Conduits on surface. The rate shall inclusive of necessary PVC Conduits and other accessories.

300

-

-

... More
Supply & laying of 3C x 1 sq mm Flexible Multistrand cable for signal / power as per specification. (from Sensor to sensor & controller) in PVC Conduits on surface. The rate shall inclusive of necessary PVC Conduits and other accessories.

150

-

-

... More
IP CCTV SURVEILLANCE SYSTEM

-

-

-

... More
Supply, Installation, Testing and Commissioning of 5MP resolution Varifocal lens IR Dome camera; 1/2.8" CMOS or better; 5MP (2560 x 1920) resolution, 30fps; Color : 0.07Lux (F1.3, 1/30sec), B/W : 0Lux (IR LED On); 3 ~ 9 mm (3X) motorized varifocal; IR viewable length: 40m (164.042ft); DC auto iris, P iris; Day & Night (ICR), WDR (120dB); BLC, WDR, HLC, SSDR; H.265, H.264, MJPEG, Minimum 4 Nos. individually configurable simultaneous streams in H.265 @ 2560 x 1920 & 30 Fps or better supported; Micro SD/SDHC/SDXC minimum memory 2 slot (Min. 512GB or higher in each) rate shall inclusive of 512GB SD/SDHC/SDXC. IPv4, IPv6, TCP/IP, UDP/IP, RTP(UDP), RTP(TCP), RTCP, RTSP, NTP, HTTP, HTTPS, SSL/TLS, DHCP, PPPoE, FTP, SMTP, ICMP, IGMP, SNMPv1/v2c/v3(MIB-2), ARP, DNS, DDNS, QoS, PIM-SM, UPnP, Bonjour, LLDP IP66, IK10; IP67, IK10, NEMA4X rated. Other technical detail shall be complied as per the technical specifications.

180

-

-

... More
Supply, Installation, Testing and Commissioning of 5MP resolution Varifocal lens IR Bullet camera; 1/2.8" 5MP (2560 x 1920) CMOS or better, 30fps; Color : 0.07Lux (F1.3, 1/30sec), B/W : 0Lux (IR LED On); 3 ~ 9 mm (3X) motorized varifocal; IR viewable length: 40m (164.042ft); DC auto iris, P iris; Day & Night (ICR), WDR (120dB); BLC, WDR, HLC, SSDR; H.265, H.264, MJPEG, Minimum 4 Nos. individually configurable simultaneous streams in H.265 @ 2560 x 1920 & 30 Fps or better supported; Micro SD/SDHC/SDXC minimum memory 2 slot (Min. 512GB or higher in each) rate shall inclusive of 512GB SD/SDHC/SDXC. IPv4, IPv6, TCP/IP, UDP/IP, RTP(UDP), RTP(TCP), RTCP, RTSP, NTP, HTTP, HTTPS, SSL/TLS, DHCP, PPPoE, FTP, SMTP, ICMP, IGMP, SNMPv1/v2c/v3(MIB-2), ARP, DNS, DDNS, QoS, PIM-SM, UPnP, Bonjour, LLDP IP66, IK10; IP67, IK10, NEMA4X rated. Other technical detail shall be complied as per the technical specifications.

173

-

-

... More
Supply, Installation, Testing and Commissioning of 5MP (2560 x 1920) * 4Lens IP Multi directional camera 4 x 1/2.8” Progressive Scan CMOS or better Multi-directional Camera, Motorized PTRZ support, Max. 60fps@2MP (H.265, H.264), 4 ~ 9 mm motorized varifocal lens, IR viewable length : 35m, H.265, H.264, MJPEG codec, supports BLC, HLC, WDR-120dB, Colour: 0.2 Lux or better B/W": 0.0 Lux (IR ON) Minimum 4 Nos, individually configurable simultaneous streams in H.264,H.265 @ 2560x1920 & 25 Fps and Motion JPEG. Micro SD/SDHC/SDXC minimum memory 2 slot (Min. 512GB or higher in each) rate shall inclusive of 512GB SD/SDHC/SDXC. IPv6, TCP/IP, UDP/IP, RTP(UDP), RTP(TCP), RTCP, RTSP, NTP, HTTP, HTTPS, SSL/TLS, DHCP, PPPoE, FTP, SMTP, ICMP, IGMP, SNMPv1/v2c/v3(MIB-2), ARP, DNS, DDNS, QoS, PIM-SM, UPnP, Bonjour, LLDP IP66, IK10; IP67, IK10, NEMA4X rated. Other technical detail shall be complied as per the technical specifications.

1

-

-

... More
Supply, Installation, Testing and Commissioning of 4K / 8MP (3840 x 2160 pixels) IR PTZ Camera with built-in Wiper, Image Sensor:1/2.8" Progressive Scan CMOS, Min. Illumination: Color: 0.1Lux, BW: 0Lux (IR LED On), 30fps, Image Compression H.264 / H.265 / MJPEG or better, White Balance, Noise Reduction: 2D/3D DNR, Blur Detection: Yes, Shutter Speed: 2 - 1/12,000 sec or better, Day & Night: True Day/Night with ICR, Optical Zoom: 30X, Digital Zoom: 12X. Focus Mode: Auto / Manual, Focal Length: 5-150 mm IR Distance: 200 Meter or better built-in IR, Optimized IR with adjustable intensity, and angle IR or better depending on the zoom ratio, Alarm Trigger: Alarm Input, Motion Detection, Blur Detection, Network Loss, Video Streams: Minimum 4 Nos, individually configurable streams in H.265@ 5MP resolution & 30 Fps, SD Card: Built in SD card slot with support up to 512GB or higher (inclusive of 512GB memory card), better Hi PoE supported, Working Temperature: -30°C~+55°C Protection Level: IP66, IK10, NEMA4X, NEMA-TS 2 (2.2.8, 2.2.9). IPv6, TCP/IP, UDP/IP, RTP(UDP), RTP(TCP), RTCP, RTSP, NTP, HTTP, HTTPS, SSL/TLS, DHCP, PPPoE, FTP, SMTP, ICMP, IGMP, SNMPv1/v2c/v3(MIB-2), ARP, DNS, DDNS, QoS, PIM-SM, UPnP, Bonjour, LLDP IP66, IK10; IP67, IK10, NEMA4X rated. Other technical detail shall be complied as per the technical specifications.

4

-

-

... More
Supplying, installation, testing and commissioning of IP Based Ultrakey Lite Control keyboard with function key, joystick, LED display, Dedicated Programmable keys for NVRs

3

-

-

... More
Supply, Installation, Testing & Commissioning of Video management software with redundancy. The VMS application must have native capability to scale into a full fetched Command & Control platform and capability to provide incident management features like Rule engine, SOP ‘s and Incident reports with no dependency on any external 3rd party software. Security Center Base software, with Primary Directory software license & 1 failover directory license. The proposed VMS platform must be UL 2900-2-3 Level 3 Cybersecurity certification. The Video Management System Platform shall be considered for at least 500 Cameras and Video Management System platform shall be redundancy of same as mentioned with reduntancy. The detailed requirement shall be referred the technical requirement provided in the tender specifications. The VMS Software shall inclusive of the following Analytics features in which will required to enable the system fullfil. The additional requirement of the Video Management Software shall be reffered in tender technical specification. The cost shall inclusive for Open Platform integrable Video Management System Software, AI Based Analytics Software Platform along with 3rd party Analytics Software and its server, Analytics Software licenses etc. The required analytics shall be considered as per the details provided in the tender specification.

1

-

-

... More
Supply, installation, testing and commissioning of Video management software (VMS) Camera License for working & failover connection. The Proposed Solution shall support native Fail over with in application with no dependency on any external application for both hardware and application redundancy. The native fail over architecture must be for both management and recording servers. Video Management System should support End to End. (i.e Clients should be able to view the video Footages Directly from the unicast stream of the Cameras) with 5 years support

373

-

-

... More
Supply, installation, testing and commissioning of Video management software (VMS) Server with Rackmount Primary and Failover server in (1: N) 6-Bay Multi-Purpose Appliance 1x Xeon E-2336 16GB RAM 2x 480GB SSD 2x 1GbE RJ45 2x 600W PSU Windows Server 2019/Latest Standard 5YR NBD KYHD Warranty. Depending on the system requirement & OEM guidelines requried quantity of Servers to be considered for primary & secondary in N+1 redundancy. (Note: The Configuration mentioned is only Minimum requirement. Vendor to consider as per OEM recommendations in case of higher configurations required as per System requirements to fulfil the complete functionality of the system and Bidder to consider the cost for the same & quote accordingly. The VMS Server shall be Hot Redundant 1+1 Configuration. This Line item Rate / Cost shall inclusive redundancy server also. No Additional Cost shall be paid for Redundancy Server. The Server shall be Balde Type and its should be Rack mounted. Tower type shall not be accepted.)

1

-

-

... More
Supply, installation, testing and commissioning of Primary Video recording server with RAID 6 2 x Xeon Silver 4210 32GB RAM, 2 x 512TB M.2 SSD, 4 x 1GbE RJ45, 2 x 10GbE SFP+, 2 x 1100W PSU, Windows Server 2019, Standard 5YR NBD KYHD Warranty - 1000 Mbps / 400 cameras (Recording: 1000 Mbps; Playback: 50 Mbps; Redirection: 500 Mbps) Storage calculation - 90days/25FPS @ 2MP/1080p FHD resolution and the rate shall inclusive of this line item. Software Generated Storage Calculation Sheet shall be furnished by Camera OEM and the same shall be submitted for approval. Maximum 200 Cameras to be considered per Recording Server with storage of those cameras and the Second Primary Server shall be considered another 200 Cameras Recording with storage of those cameras. Hence 2 Nos of Primary Recording Server with 200 Cameras and its storages in each server to be considered. The rate shall inclusive of all CCTV Video Storage Box and the Storage Box's Surveillance Hard Disk Drive shall have a minimum consideration of 7200 RPM or higher side. No addtional cost shall be provided for CCTV Video Storage Device Box. (Note: The Configuration mentioned is only Minimum requirement. Vendor shall be consider as per the CCTV Camera OEM & Video Managment System Software OEM recommendations, in case of higher configurations shall be required to enable the functional requirements and consider the cost for the same & quote accordingly. Bidder shall be considered the specified configuration if the CCTV Camera OEM & Video Managment System Software do not have an objection. No deviation shall be accepeted.)

1

-

-

... More
Supply, installation, testing and commissioning of Failover Video recording server with RAID 6, 1 x Xeon Silver 4210 32GB RAM, 2 x 512GB M.2 SSD, 4 x 1GbE RJ45, 2 x 1100W PSU Windows Server 2019 Standard 5YR NBD KYHD Warranty - 1000 Mbps / 400 cameras (Recording: 1000 Mbps; Playback: 50 Mbps; Redirection: 500 Mbps) Storage calculation - 30 days / 25FPS @ 2MP/1080p FHD resolution. Generated Storage Calculation Sheet shall be furnished by Camera OEM and the same shall be submitted for approval. Maximum 400 Cameras and its storage of fail over Facility Needs to be considered in Fail Over Recording Server. The rate shall inclusive of all CCTV Video Storage Hard Disk Drive and the Surveillance Hard Disk Drive shall have a minimum consideration of 7200 RPM or higher side. No addtional cost shall be provided for CCTV Video Storage Device. (Note: The Configuration mentioned is only Minimum requirement. Vendor shall be consider as per the CCTV Camera OEM & Video Managment System Software OEM recommendations, in case of higher configurations shall be required to enable the functional requirements and consider the cost for the same & quote accordingly. Bidder shall be considered the specified configuration if the CCTV Camera OEM & Video Managment System Software do not have an objection. No deviation shall be accepeted.)

1

-

-

... More
Supply, installation, testing and commissioning of Client workstation Intel core 9th Generation Intel Core i9 Processor by latest generation or better, 16GB DDR3 RAM, 64-bit operating system, 1TB SSD for OS and Security Center applications, with a minimum of 16 GB of free disk space to install the Security Center client application, 1TB SATA Hard disk with 7200rpm, GbE network interface card, DVD-RW standard keyboard & Mouse with Dual NVIDIA® GeForce® RTX 2080 video card with 21" 4K / UHD LED MONITOR LED MONITOR. Minimum 4 HDMI,1 parallel, 8 USB 2.0, 1 serial, 2 Ultra ATA/100, 2optional IEEE1394, 1 USB Keyboard, 1 USB Mouse, 1 video, 1 Microphone jack, 1 Line-in jack, 2 x 1GBPS RJ-45 Interface Port. (Note: The Configuration mentioned is only Minimum requirement. Vendor shall be consider as per the CCTV Camera OEM & Video Managment System Software OEM recommendations, in case of higher configurations shall be required to enable the functional requirements and consider the cost for the same & quote accordingly. Bidder shall be considered the specified configuration if the CCTV Camera OEM & Video Managment System Software do not have an objection. No deviation shall be accepeted.)

6

-

-

... More
Supply, Installation, Testing & Commissioning of Main Viewing Screens with wall mount 4 x 55" 4K UHD LED Screens, with HDMI/VGA outputs, PC inputs. Screens should have 2 ms or better response time, Energy Star compliant & capable to operate for 24x7 operation .It shall come with remote control and shall have various picture mode options for data representation with all necessary fixing accessiories for viewing. Note: The display shall be mounted 2 x 2 matrix and all four screen to be considered as single display screen / monitor. One input from Server / Client / CCTV Client PC shall be interfaced with Monitor Station. Hence the contractor must be be considered the required Encoder / Decoder / Splitter / if any Software cost shall be added in this display rate itself to enable the solutions. Bidders shall be considered the necessary additional equipment cost in this line item. No additional cost shall be provided if will require to comply the above requirement.

1

-

-

... More
Supply, installation, testing and commissioning of 3 Metre Length Pole with Base Plate (250 x 250 x 6mm) 76.10mm OD x 3.65mm Thick x 3000mm Length Integral junction chamber flush with the pole for termination of CAT-6A and power cables. Including Bakelite sheet. Provided with a camera mounting plate - fixed to the pole with provision of holes for camera mounting - holes dimensions to be provided by you. PU coated through 5 tank cleaning process and with 2 coats of primer and 2 coats of PU paint and topcoat for extra weather protection. Poles are fine finished. The rate shall inclusive of all the necessary camera mounting accessories, back boxes, Termination Junction Boxes for power supply (if required), 4 Nos of Anchor bolt shall be 25mm dia and 500mm length, 2 Nos of 32mm GI pipe medium class collar bend for cable entry at the bottom of the foundation etc., to be considered. The Pole Cost shall be inclusive of all required RCC foundations as mentioned the foundation details of 450mm (L) x 450mm (W) x 1000mm (H) RCC M25 Grade. The Pole cost shall inclusive of excavation, shuttering, foundations and backfilling the soil etc. no extra cost shall be provided to Civil contractor.

10

-

-

... More
Supply, installation, testing and commissioning of 6 Metre Length Pole with Base Plate (250 x 250 x 6mm) 76.10mm OD x 3.65mm Thick x 6000mm Length Integral junction chamber flush with the pole for termination of CAT-6A and power cables. Including Bakelite sheet. Provided with a camera mounting plate - fixed to the pole with provision of holes for camera mounting - holes dimensions to be provided by you. PU coated through 5 tank cleaning process and with 2 coats of primer and 2 coats of PU paint and topcoat for extra weather protection. Poles are fine finished. The rate shall inclusive of all the necessary camera mounting accessories, back boxes, Termination Junction Boxes for power supply (if required), 4 Nos of Anchor bolt shall be 25mm dia and 500mm length, 2 Nos of 32mm GI pipe medium class collar bend for cable entry at the bottom of the foundation etc., to be considered. The Pole Cost shall be inclusive of all required RCC foundations as mentioned the foundation details of 450mm (L) x 450mm (W) x 1000mm (H) RCC M25 Grade. The Pole cost shall inclusive of excavation, shuttering, foundations and backfilling the soil etc. no extra cost shall be provided to Civil contractor.

4

-

-

... More
INTEGRATED BUILDING MANAGEMENT SYSTEM

-

-

-

... More
MAIN IBMS SERVER HARDWARE (1 MAIN + 1 STANDBY) Supply, installation, testing and commissioning of 4th Gen Intel Xeon Scalable (1.9 GHZ / 6-CORE / 15MB / 85W) PROCESSOR , 8 DIMM SLOTS 2Nos. of 8GB DDR4 RAM , WITH NVIDIA GRAPHIC CARD, 8 LFF (3.5INCH) HOT PLUG SAS/SATA OPEN BAY 4 Nos. of HP 2TB 6G SATA 7.2K 3.5IN MDL SC HDD SAS/SAT H240 SMART HBA WITH ENCRYPTION KEY EXTERNAL DVD R/W 1 x 800W/900W GOLD HT PLG PWR ETHERNET 1GB 2-PORT 36I ADAPTER HP ILO (FIRMWARE: HP ILO 4) WITH 2GB NAND + HP STANDARD KEYBOARD & MOUSE + MICROSOFT WINDOWS SERVER 2012 STANDARD WITH ANTIVIRUS AND MS SQL SERVER LICENSE + The Communication protocol shall be one of the Industry Standard Open Protocols such as BACNet, MODBUS etc. System should be scalable. (Note: The Configuration mentioned is only Minimum requirement. Vendor to consider as per OEM recommendations in case of higher configurations required as per System requirements to fulfil the complete functionality of the system and Bidder to consider the cost for the same & quote accordingly. The BMS Server shall be Hot Redundant 1+1 Configuration. This Line item Rate / Cost shall inclusive redundancy server also. No Additional Cost shall be paid for Redundancy Server. The Server shall be Balde Type and its should be Rack mounted. Tower type shall not be accepted.)

1

-

-

... More
Supply, installation, testing and commissioning of 3D Realtime Graphical User Interface (GUI) software. The system should be accessible from anywhere on LAN or WAN or Ethernet without additional licenses. The Communication protocol shall be one of the Industry Standard Open Protocols such as BACNet, LON etc. Software should be scalable & no extra communication driver license required shall be acceptable. Software shall have a inbuilt Server licenses (Main + Redundant + Cloud Server) and 5 concurrent user licenses with upgradable to unlimited web user license. a. The rate shall inclusive of BTU billing software capable of generating necessary report/billing format for direct billing to the tenants. Provision for Customisation of Software as per customer. b. Thrd party software shall be accepted for BTU Billing activities. However the same software shall be proven technology in India Market and the OEM of BTU Meter Billing Software must submit the completion certificate and healthy certificate of the Software functional from Multi-User Tenant Corporate Customer. c. The rate shall inclusive of all the furnished IO points as per the BMS IO Summary with inbuilt soft integration modules for 3rd party system integration for above server and client. d. The Proposing 3D Graphical User Interface Software shall have a 3000 Hard wired interface points and 15000 3rd Party Integration soft points as per the IO Summary. However, this is not limited to the OEM products incase it may require to add on any additional 3rd party softwares only for Energy Management Dasboard and its billing, HVAC (BTU) Billing software without any additional cost. e. In addition to that, the above said Software shall have minimum 20% of spare points over and above the IO count mentioned in the description for future enablement.

1

-

-

... More
Supply, installation, testing and commissioning of A 4 size Laserjet Printer suitable for the application, with driver software.

4

-

-

... More
Supply, installation, testing and commissioning of Client workstation Intel core 9th Generation Intel Core i9 Processor by latest generation or better, 16GB DDR3 RAM, 64-bit operating system, 1TB SSD for OS and Security Center applications, with a minimum of 16 GB of free disk space to install the Security Center client application, 1TB SATA Hard disk with 7200rpm, GbE network interface card, DVD-RW standard keyboard & Mouse with Dual NVIDIA® GeForce® RTX 2080 video card with 21" FULL HD LED MONITOR. Minimum 4 HDMI,1 parallel, 8 USB 2.0, 1 serial, 2 Ultra ATA/100, 2optional IEEE1394, 1 USB Keyboard, 1 USB Mouse, 1 video, 1 Microphone jack, 1 Line-in jack, 2 x 1GBPS RJ-45 Interface Port (Note: The Configuration mentioned is only Minimum requirement. Vendor to consider as per OEM recommendations in case of higher configurations shall be required as per project functional requirements and the bidder to consider the cost for the same & quote accordingly. The bidder needs to consider the same configuration if OEM will not have an objection for the mentioned specifications. No deviation shall be accepeted.)

4

-

-

... More
IP DDC CONTROLLERS WITH NATIVE BACNet / IP CONFIGURABLE: Supply, installation, testing and commissioning of DDC CONTROLLERS shall be Standalone and Networkable 32 Bit DDC Controllers with I/O module as per enclosed IO List. The controllers shall be capable of standalone operation with real-time clock and historical database. The DDC's shall be capable of peer to peer communication without help of system interface controller or PC. The DDCs and its Enclosures shall be with suitable IP 55 enclosure for indoor mounted type and for all outdoor type controllers it shall be IP66 complete with all wiring and accessories. All DDC Controllers shall have a inbuilt IoT enabled communication protocol to connect and configure with Cloud BMS Server directly without any gateway devices. Bidder shall Quote Accordingly. Gateway controllers shall not be accepted to enable IoT Platform to interface with Cloud BMS Server.

-

-

-

... More
DDC TYPE ID - 01 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 02 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 03 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 04 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 05 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 06 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 07 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 08 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 09 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 09 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 09 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 09 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 09 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 09 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 10 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 09 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 11 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 11 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 11 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 11 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 11 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 11 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 12 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 11 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 11 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 11 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 13 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 13 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 13 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 13 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 13 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 13 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 14 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 13 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 13 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 13 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 15 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 15 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 15 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 15 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 15 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 16 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 15 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 15 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 15 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 17 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 17 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 17 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 17 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 17 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 18 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 17 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 17 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 17 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 19 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 19 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 20 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 20 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 21 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 20 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 20 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 20 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 22 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 22 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 22 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 23 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 22 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 22 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 22 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 22 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 22 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 24 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 24 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 24 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 24 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 24 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 24 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 25 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 24 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 26 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 26 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 26 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 26 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 26 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 27 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 26 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 26 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 28 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 29 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 30 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 31 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 32 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 33 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 34 (Refer IO Summary)

1

-

-

... More
DDC TYPE ID - 35 (Refer IO Summary)

1

-

-

... More
PORTABLE OPERATOR TERMINAL: Supply, installation, testing and commissioning of Portable Operator Terminal : capable of connecting to one of the Controllers on the Communication bus and view parameters of the complete system. The Terminal should be capable of viewing / changing parameters and trend the specified parameters as per requirement

3

-

-

... More
THIRD PARTY SOFT INTEGRATION: Supply, installation, testing and commissioning of Required Gateways / Open Protocol Software for integrating the foll third party system communicating on one of the Standard Open Protocols such as BACNet , MODBUS, M-Bus, J Bus etc - Vendor to considered required No. of Integrators for soft point qty's mentioned in IO summary. Maximum qty in one loop cannot exceed 20 nos. Accordingly integrator qty to be selected. a. Energy Meters (180 meters * 7 points each = Total 1260 points - Modbus over RS485 protocol) b. DG / Transformer Sync panel - Total 200 points - Modbus over RS485 protocol) c. UPS - (40 points - Modbus over RS485 protocol / BACnet over MSTP) d. Secondary pump PLC panel (100 points - Modbus over RS485 protocol / BACnet over MSTP) e. EC fan (80 Nos- 10 points each - Total 800 points - Modbus over RS485 protocol / BACnet over MSTP) f. VFD (15 Nos- 10 points each - Total 150 points - Modbus over RS485 protocol) g. Basement Ventilation Panel (4 panels - 50 points each - Total 200 points - Modbus over RS485 protocol / BACnet over MSTP). h. Fire alarm panels & MCC panel for pumps (5000 points - Modbus over RS485 protocol / BACnet over MSTP) i. CHW cassette / Hi wall units (30 Nos -5 points each - Total 150 points - Modbus over RS485 protocol) j. Water meter integration (10 Nos - 5 points per meter - total 50 points - Modbus over RS485 protocol / BACnet over MSTP) k. Elevator monitoring system - (9 Nos - 5 points each - total 45 points - Modbus over RS485 protocol / BACnet over MSTP) l. Tenent Billing system - (1000 points - M-Bus / Modbus over RS485 protocol / BACnet over MSTP) m. Chiller - (100 points- Modbus over RS485 protocol / BACnet over MSTP) n. PHE PUMP PLC - (100 points - Modbus over RS485 protocol / BACnet over MSTP) o. Solar System Panel Integration - (100 points - Modbus over RS485 protocol / BACnet over MSTP) p. EV charging point integration - (40 Nos Nodes (20 Two Wheeler + 20 Four Wheeler) - 100 Points - Modbus over RS485 protocol / BACnet over MSTP) q. HSD Tank Flow Monitor Integration - (4 Nos * 25 Points = 100 Points - Modbus over RS485 protocol / BACnet over MSTP) r. HSD Tank Consumption Meter Integration - (4 Nos * 25 Points = 100 Points - Modbus over RS485 protocol / BACnet over MSTP)

1

-

-

... More
Temperature Sensors - Duct Type - Indoor. Supply, installation, testing and commissioning of Temperature Sensors - Duct Type - Indoor. shall be of the Resistance Temperature detector (RTD) type or thermistor. These shall be two wire type . It shall be with rigid stem and of averaging type. These shall be suitable for duct installation. Accuracy shall be ± 2 deg C. Temperature range shall be 0 -50 deg C.

101

-

-

... More
Temperature Sensors - Immersion type - Cold Water - Indoor Supply, installation, testing and commissioning of Temperature Sensors - Immersion type - Cold Water - Indoor shall be of the Resistance Temperature detector (RTD) type or thermistor. These shall be two wire type. It shall be provided with separate Brass thermo well. These shall be manufactured from bar stock with hydrostatic pressure rating of at least 10 kgf/cm2. Accuracy shall be ± 2 deg C. Temperature range shall be 0 -50 deg C.

262

-

-

... More
Temperature & RH Sensors - Wall Mount type - Outdoor (For Ambient T & RH). Supply, installation, testing and commissioning of Temperature & RH Sensors - Wall Mount type - Outdoor (For Ambient T & RH). shall be provided with a sun shield. Sensors shall be of capacitance type with an effective sensing range of 0% to 93% RH. Accuracy shall be + 2% or better. Duct mounted humidity sensors shall be provided with a sampling chamber. Sensors shall be provided with a housing. Temperature range shall be 0 -50 deg C and accuracy shall be ± 2 deg C. Temperature sensor shall be of the Resistance Temperature detector (RTD) type or thermistor

1

-

-

... More
Temperature & RH Sensors - Wall Mount type - Indoor (For Room T & RH) with display Supply, installation, testing and commissioning of Temperature & RH Sensors - Wall Mount type - Indoor (For Room T & RH) with display shall be of capacitance type with an effective sensing range of 0% to 93% RH. Accuracy shall be + 2% or better. Duct mounted humidity sensors shall be provided with a sampling chamber. Temperature range shall be 0 -50 deg C and accuracy shall be ± 2 deg C. Temperature sensor shall be of the Resistance Temperature detector (RTD) type or thermistor

19

-

-

... More
Temperature & RH Sensors - Duct Mount type - Indoor (For Room T & RH) Supply, installation, testing and commissioning of Temperature & RH Sensors - Duct Mount type - Indoor (For Room T & RH) shall be of capacitance type with an effective sensing range of 0% to 93% RH. Accuracy shall be + 2% or better. Duct mounted humidity sensors shall be provided with a sampling chamber. Temperature range shall be 0 -50 deg C and accuracy shall be ± 2 deg C. Temperature sensor shall be of the Resistance Temperature detector (RTD) type or thermistor

69

-

-

... More
Velocity Sensors - Duct Mount type - Indoor Supply, installation, testing and commissioning of Air Velocity Sensor shall be integrated Surface / Duct mounted type on the field. These shall work on 24V AC/DC supply with +/- 10% variation the output being standard type i.e. 4-20 mA / 0- 10 Volts etc with an accuracy of +/- 3%

89

-

-

... More
Duct Static Pressure Sensor (For AHU static pressure monitoring). Supply, installation, testing and commissioning of Duct Static Pressure Sensor (For AHU static pressure monitoring). Range shall be 0-500 Pa, Accuracy at ±1% FS, It shall be IP54 rated. Vertically mounted with pressure connections pointing downwards.

77

-

-

... More
Differential Pressure Switch for Fan Status (Outdoor type) Supply, installation, testing and commissioning of Differential Pressure Switch for Fan Status (Outdoor type) shall be diaphragm operated. Switches shall be supplied with air connections permitting their use as static or differential pressure switches. The switch shall be of differential pressure type complete with connecting tube and metal bends for connections to the duct. The housing shall be IP 67 rated.

8

-

-

... More
Differential Pressure Switch for Fan Status (Indoor type) Supply, installation, testing and commissioning of Differential Pressure Switch for Fan Status (Indoor type) shall be diaphragm operated. Switches shall be supplied with air connections permitting their use as static or differential pressure switches. The switch shall be of differential pressure type complete with connecting tube and metal bends for connections to the duct

24

-

-

... More
Differential Pressure Switch - Filter Status (Outdoor type) Supply, installation, testing and commissioning of Differential Pressure Switch - Filter Status (Outdoor type) shall be diaphragm operated. Switches shall be supplied with air connections permitting their use as static or differential pressure switches. The switch shall be of differential pressure type complete with connecting tube and metal bends for connections to the unit. The housing shall be IP 67 rated.

16

-

-

... More
Differential Pressure Switch - Filter Status (Indoor type) Supply, installation, testing and commissioning of Differential Pressure Switch - Filter Status (Indoor type) shall be diaphragm operated. Switches shall be supplied with air connections permitting their use as static or differential pressure switches. The switch shall be of differential pressure type complete with connecting tube and metal bends for connections to the unit

163

-

-

... More
Water Level Switch Supply, installation, testing and commissioning of Water Level Switch shall be paddle type and suitable for the type of liquid flowing in the line. Output shall be 1NO/1NC potential free

6

-

-

... More
Hydrogen Sensor: Supply, installation, testing and commissioning of Wall Mount type - Indoor shal be flame proof type. Accuracy shall be +/- 10% FSD of H2%. Response time shall be less than 3 seconds

1

-

-

... More
CO2 Sensor - Duct Type - Indoor (in AHU Room Return Air path) Supply, installation, testing and commissioning of CO2 Sensor - Duct Type - Indoor (in AHU Room Return Air path) 24V AC/DC supply with the output being standard type i.e. 4-20 mA / 0- 10 Volts etc. Response time of the detector shall be 10 minutes. Range of the sensor shall be 0 to 2000 PPM

89

-

-

... More
Supplying, laying, termination, testing and commissioning of signal cables. 2 Core x 1.0 Sqmm, PVC insulated, tinned copper conductor cable Armoured Shielded ATC FRLS cable.

13338

-

-

... More
Supplying, laying, termination, testing and commissioning of signal cables. 4 Core x 1.0 Sqmm, PVC insulated, tinned copper conductor cable Armoured Shielded ATC FRLS cable.

15620

-

-

... More
Supplying, laying, termination, testing and commissioning of signal cables. 2 Core x 1.5 Sqmm, PVC insulated, tinned copper conductor cable Armoured Shielded ATC FRLS cable.

6000

-

-

... More
Supplying, laying, termination, testing and commissioning of signal cables. 3 Core x 1.5 Sqmm, PVC insulated, copper conductor cable Un-Armoured / Flexible FRLS cable.

501

-

-

... More
Supplying and fixing of following sizes of Medium Class PVC conduit along with accessories in surface / recess including cutting the wall and making good the same in case recessed conduit as required 20mm PVC Conduit.

2837

-

-

... More
Supplying and fixing of following sizes of Medium Class PVC conduit along with accessories in surface / recess including cutting the wall and making good the same in case recessed conduit as required 25mm PVC Conduit.

5319

-

-

... More
Supplying and installing of perforated Hot dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5% in convenient sections, joined with connectors, suspended from the ceiling with G.I suspenders including G.I bolts & nuts, etc.as required. 300 mm width x 50 mm depth x 1.6 mm thickness

2679

-

-

... More
Supplying and installing of perforated Hot dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5% in convenient sections, joined with connectors, suspended from the ceiling with G.I suspenders including G.I bolts & nuts, etc.as required. 225 mm width x 50 mm depth x 1.6 mm thickness

1141

-

-

... More
Supplying and installing of perforated Hot dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5% in convenient sections, joined with connectors, suspended from the ceiling with G.I suspenders including G.I bolts & nuts, etc.as required. 100 mm width x 50 mm depth x 1.6 mm thickness

110

-

-

... More
Supply and providing of PVC cable truf complete with all fittings and accessories 100mm (W) x 75mm (D)

660

-

-

... More
DATA NETWORKING & TELECOM SYSTEM

-

-

-

... More
Supply, installation, testing and commissioning of Core Switch shall have minimum 48 x 1/10/25 SFP+, 4 *40/100G QSFP28 ports. Note: Bidder shall refer the Technical Tender Specifications for details to select the products.

2

-

-

... More
Supply, installation, testing and commissioning of 10GSR 850nm short-haul (300m with MMF) -10Gb/s SFP+ Transceiver Module for Uplink for Non POE, POE switch

84

-

-

... More
Supply, installation, testing and commissioning of 40G QSFP+ Transceiver Module for Core switch

4

-

-

... More
48 Port PoE+ Edge / Distribution Switch: Supply, installation, testing and commissioning of Edge Switch shall have minimum 48 *100/1000 RJ45 PoE+ ports and 4 x 1/10G SFP+ ports with redundant power supply from day-1. Min PoE budget (48Port * 30W = 1440) 1440 Watts. Note: Bidder shall refer the Technical Tender Specifications for details to select the products.

19

-

-

... More
24 Port PoE+ Edge / Distribution Switch: Supply, installation, testing and commissioning of Edge Switch shall have minimum 24 *100/1000 RJ45 PoE+ ports and 4 x 1/10G SFP+ ports with redundant power supply from day-1. Min PoE budget (24Port * 30W = 720) 720 Watts. Note: Bidder shall refer the Technical Tender Specifications for details to select the products.

4

-

-

... More
8 Port PoE+ Edge / Distribution Switch: Supply, installation, testing and commissioning of Edge Switch shall have minimum 8 *100/1000 RJ45 PoE+ ports and 4 x 1/10G SFP+ ports with redundant power supply from day-1. Min PoE budget (8Port * 80W = 640) 640 Watts. Note: Bidder shall refer the Technical Tender Specifications for details to select the products. The rate shall inclusive of necessary 16A Power Socket, Switch, LIU, Patch Panel, IP65 Rating weather proof Enclosure Box with DIN rail Mount arrangement to mount the Network Switch, LIU, Patch Panel etc. No additional cost shall be provided for any excess item to be claimed.

6

-

-

... More
SDN Controller: Supply, installation, testing and commissioning of Centralized management appliance or SDN Controller Note: Bidder shall refer the Technical Tender Specifications for details to select the products.

2

-

-

... More
WAN Router: Supply, installation, testing and commissioning of 24 port 1/10G SFP+ switch Note: Bidder shall refer the Technical Tender Specifications for details to select the products.

2

-

-

... More
Wi-Fi Access Points: Supply, installation, testing and commissioning of Wi-Fi Access Points Note: Bidder shall refer the Technical Tender Specifications for details to select the products.

7

-

-

... More
Supply, Installation, Testing & Commissioning of Cat 6A U/FTP or F/UTP Cable, 4 pair, 23 AWG , LSZH jacket & UL listed and ETL tested. Bidder shall refer the details of technical requirement in Technical Specifications document. Note: 25 Years warranty certification by OEM with Fluke test report shall be furnished by the contractor. There no additional cost shall be provided for Fluke test and certifications.

46145

-

-

... More
Supply, Installation, Testing & Commissioning of 4 Pair Un-armoured 0.5mm Cable - Telephone

7260

-

-

... More
Supply, Installation, Testing & Commissioning CAT 6A Modular 24 Port Patch Panel fully loaded (Tool Less) - with Cable Manager

40

-

-

... More
Supply, Installation, Testing & Commissioning of Tool-less Cat 6A STP Information Outlet with shutter or integrated dustcover

354

-

-

... More
Supply, Installation, Testing & Commissioning of RJ 11 Information Outlet with shutter or integrated dustcover

123

-

-

... More
Supply, Installation, Testing & Commissioning of Single / Dual Face plate for Field side, the rate shall inclusive of Flush Box - 3 Module to mount the face plate in surface, conseal, ceiling etc.

283

-

-

... More
Supply, Installation, Testing & Commissioning of Cat 6A - RJ 45 IDC plug / CCA connector UL listed and ETL tested for CCTV - Camera Side

475

-

-

... More
Supply, Installation, Testing & Commissioning of CAT 6A UTP LSZH Patch card - 2 M length

1201

-

-

... More
Supply, Installation, Testing & Commissioning of 12 Core OM4 Multi Mode fiber, Outdoor ECCS Armoured Unitube - LSZH outer sheath, 1500N Tensile Strength, 2000N Crush Resistance and OD 9mm. Bidder shall refer the details of technical requirement in Technical Specifications document. Note: 25 Years warranty certification by OEM with Fluke test report shall be furnished by the contractor. There no additional cost shall be provided for Fluke test and certifications.

3757

-

-

... More
Supply, Installation, Testing & Commissioning of 1U Sliding Fibre panel (LIU) rack-mount 24-Fiber with splice holder, cable spool and loaded with LC Adapter and LC OM4 Pigtail at Each HUB Room

20

-

-

... More
Supply, Installation, Testing & Commissioning of LC/LC Single Mode / Multi mode Patch Cord MM OM4 bending insensitivity - 2M

88

-

-

... More
Supply and Installation of 19", Rack 42U, closed rack 800W x 1000mm Front & Rear Perforated Door with lock, 1 Shelf 575 mm, castors and mounting hardware packet of 20, PDU 6 x 5/15 A(1) Note: Bidder shall refer the details of technical requirement in Technical Specifications document.

8

-

-

... More
Supply and Installation of 19", Rack 42U, 800mm(W) x 800mm (D) with Front & Rear Perforated Door with lock, 1 Shelf 575 mm, castors and mounting hardware packet of 20, PDU 6 x 5/15 A(1) Note: Bidder shall refer the details of technical requirement in Technical Specifications document.

17

-

-

... More
Supply and Installation of 19", Rack 32U, 800mm(W) x 800mm (D) with Front & Rear Perforated Door with lock, 1 Shelf 575 mm, castors and mounting hardware packet of 20, PDU 6 x 5/15 A(1) Note: Bidder shall refer the details of technical requirement in Technical Specifications document.

1

-

-

... More
Supply, Installation, Testing & Commissioning of Server Gateway like Architecture VoIP Based IP PBX, with Industry Standard CPU based on IP at core with support for hot redundant configuration. IP PBX System Machine should be inbuilt 256 Analog and 100 IP Extensions and it can be expandable upto 896 Analog & 400 IP Extensions, 8 Trunk line + 30 SIP Trunk + 8 Digital Extension. Note: Software shall be installed in Access Control System Servers and Client licenses to be installed in Access Control System Workstation.

1

-

-

... More
Supply, Installation, Testing & Commissioning of 24 Key Digital phone - Operator phone, 480 x 272 pixels back light color display or better with LCD Display

2

-

-

... More
Supply, Installation, Testing & Commissioning of IP Phone : Display: 2.8 Inch, 320x240 Color Display Gigabit Ethernet Port

57

-

-

... More
Supply, Installation, Testing & Commissioning of Basic Analog Instruments

11

-

-

... More
Supply, Installation, Testing & Commissioning of 10 Pair Un-armoured 0.5mm Cable - Telephone

800

-

-

... More
Supply, Installation, Testing & Commissioning of 20 Pair Un-armoured 0.5mm Cable - Telephone

600

-

-

... More
Supply, Installation, Testing & Commissioning of 50 Pair Un-armoured 0.5mm Cable - Telephone

75

-

-

... More
Supplying and fixing of following sizes of Medium Class PVC conduit along with accessories in surface / recess including cutting the wall and making good the same in case recessed conduit as required 25mm PVC Conduit.

26838

-

-

... More
Supplying and Laying of HDPE Pipe 90mm (OD) / 76mm (ID). The rate shall inclusive of all necessary excavation, backfilling, sand filling, Brick protection and required service chamber etc. Note: OD - Outer Diameter & ID - Inner Diameter

600

-

-

... More
Supply, Installation, Testing & Commissioning of 10 pair Floor MDF Box with krone module with Accessories to compete the work. The rate shall inclusive of All necessary jumper cables from IP-ABX Machine and interconnection tags, IP 55 Enclosures, Lock and keys etc.

8

-

-

... More
Supply, Installation, Testing & Commissioning of 20 pair Floor MDF Box with krone module with Accessories to compete the work. The rate shall inclusive of All necessary jumper cables from IP-ABX Machine and interconnection tags, IP 55 Enclosures, Lock and keys etc.

6

-

-

... More
Supply, Installation, Testing & Commissioning of 50 pair Floor MDF Box with krone module with Accessories to compete the work. The rate shall inclusive of All necessary jumper cables from IP-ABX Machine and interconnection tags, IP 55 Enclosures, Lock and keys etc.

1

-

-

... More
Supply, Installation, Testing & Commissioning of 500 (250 + 250) pair Master MDF Box with krone module with Accessories to compete the work. The rate shall inclusive of All necessary jumper cables from IP-ABX Machine and interconnection tags, IP 55 Enclosures, Lock and keys etc.

1

-

-

... More
INTEGRATED COMMAND & CONTROL CENTRE

-

-

-

... More
Supply, installation, Testing and Commissioning of 24x7 Commercial Grade LED Display Panel. 4K Resolution (3840 pixels wide by 2160 pixels tall (8.3 megapixels)) 42" LED Display shall be considered as 4 x 3 matrix (12 Nos). The rate shall inclusive 12 Nos of Video Display Panel and its all necessary mounting arrangement at site. Contractor shall be considered the total display panel to be 12 Nos in Lot. LED Type: IPS, LED with direct backlighting, Viewable image area (diagonal): 106,7 cm (42 inch in each panel) widescreen; diagonally measured, Brightness (typical): 400 cd/m2, Aspect ratio: 16:9, Viewing angle (typical): Up to 178° horizontal/178° vertical (10:1 minimum contrast ratio), Contrast ratio (typical): 1000:1, Dynamic contrast ratio (typical): 5,000,000:1, Response time (typical): 6 ms (gray to gray), Pixel pitch: ~ 0.4833 mm, Color gamut (typical): 68%, Color support3: Can display up to 16.7 million colors, Horizontal frequency: 30 to 83 kHz, Vertical frequency: 50 to 60 Hz, Native resolution: 4K @ 60 Hz, Maximum pixel clock speed: 150 MHz (Digital and Analog), Anti-glare: Yes, Default color temperature: Medium (9300K), Plug and play: Yes, Input signal: RGB/VGA and DisplayPort 1.1a and HDMI (HDCP support on DisplayPort and HDMI), Output: RGB/VGA and HDMI and DisplayPort 1.1a out for tiling and USB 3.0 included. The rate shall inclusive of Video Display Spiltter, Encoder, Decoder, Multi-Screen casting requirement as per the site considitions.

1

-

-

... More
Supply, installation, Testing and Commissioning of Server (N + 1) Redundancy with the following configuration for ICCC Operations: The cost shall inclusive of Redundancy server also. There is no additional cost shall be provided for Redundancy Server. ICCC Server machine : Includes Server, Windows Server Standard, SQL Server Standard. Intel Xeon Silver 3104 Processor, 8 MB L3 Cache, 6 Cores, 6 Threads 3 x 8GB RDIMM, 2666MT/s 1 x 1TB 10K RPM SAS 2.5in Hot-plug Hard Drive 2GB Network Card Windows Server 2016/2019 Standard , 104, 12 function key DD, 21" LCD Monitor, Wireless Mouse, USB Keyboard, CD/DVD Combo Writer, TCP/IP Connection. (Note: The Configuration mentioned is only Minimum requirement. Vendor to consider as per OEM recommendations in case of higher configurations shall be required as per project functional requirements and the bidder to consider the cost for the same & quote accordingly. The bidder needs to consider the same configuration if OEM will not have an objection for the mentioned specifications. No deviation shall be accepeted.) The ICCC Server shall be Hot Redundant 1+1 Configuration. This Line item Rate / Cost shall inclusive redundancy server also. No Additional Cost shall be paid for Redundancy Server. The Server shall be Balde Type and its should be Rack mounted. Tower type shall not be accepted

1

-

-

... More
Supply, installation, Testing and Commissioning of Firewall with the following configuration for ICCC Operations: Physical attributes: Should be mountable on 19” Rack, odular Chassis /Appliance Design, Internal redundant power supply Interfaces: Should have minimum 4X1GE ports and 2X10G port with necessary SFP loaded from day one. Should be scalable to add 2 or more 10G ports in future, Console Port 1 number. Performance and Availability: Encrypted throughput: minimum 2 Gbps, Concurrent connections: up to 100,000, Simultaneous VPN tunnels: 2000 Routing Protocols: Static Routes, RIPv1, RIPv2, OSPF. Protocols: TCP/IP, PPTP, RTP, L2TP, IPSec, GRE, DES/3DES/AES, PPPoE, EAP-TLS, RTP, FTP, HTTP, HTTPS, SNMP, SMTP, DHCP, DNS, Support for Ipv6, IPSEC Other support: 802.1Q, NAT, PAT, IP Multicast support, Remote Access VPN, Time based Access control lists, URL Filtering, support VLAN, Radius/ TACACS, Support multilayer firewall protection, Traffic shaping, Bandwidth monitoring QoS: QoS features like traffic prioritization, differentiated services, committed access rate. Should support for QoS features for defining the QoS policies. Management: Console, Telnet, SSHv2, Browser based configuration, SNMPv1, SNMPv2 , SNMPv3. Additional Features: Should have inbuilt HDD of minimum 500 GB, Should support DDoS protection Certifications: ICSA/NDPP/EAL4

1

-

-

... More
Supply, installation, Testing and Commissioning of Enterprises Network Management System for ICCC & Building Operations as per the details required in Technical Specifications. The Enterprises Network Management System subcription shall be considered for 36 months from the handing over the project.

1

-

-

... More
Supply, installation, Testing and Commissioning of Integrated Command & Control System Software for the following requirement. The ICCC shall integrate with the following Systems/ Platforms through SDKs and APIs shared by their provider: a. Video Surveillance System - 1000 Nos Cameras Points through OnVIF configurable b. Building Management System - 25000 Points IO Points with inclusive of Hard wired & Soft integration c. Security Access Control System - 200 Nos Doors in which inclusive of Gates Security Access to be integrated d. Fire Detection & Alarm System - 10000 Nos Detectors & Modules to be integrated e. Public Address System - 3000 Points of PA System related Components through IP Connection f. Water PLC SCADA System - 1000 Points from various Water Station inclusive of Hard wired & Soft integration g. Energy Management System - 3000 IO Points with inclusive of Hard wired & Soft integration h. Solid waste management System - 500 IO Points with inclusive of Hard wired & Soft integration i. Smart Metering for Utilities (Water, Electricity, Gas) - 1000 IO Points with inclusive of Hard wired & Soft integration j. Communication Network Mgmt. - 2000 Nodes with inclusive of Hard wired & Soft integration through IP Configurable k. Solar System Panel Integration - 100 IO Points with inclusive of Hard wired & Soft integration p. EV charging point integration - 100 IO Points with inclusive of Hard wired & Soft integration q. HSD Tank Flow Monitor Integration - 100 Points with inclusive of Hard wired & Soft integration r. HSD Tank Consumption Meter Integration - 100 Points with inclusive of Hard wired & Soft integration Note: The detailed requirement shall be as per the technical tender specification. The cost shall inclusive of the requirements are required as per the Tender specifications. No excess claim shall be accepted post award the contract to the successful bidder. Software shall have a inbuilt Server licenses (Main + Redundant) and 20 concurrent user / Client licenses licenses with upgradable to unlimited web user license. In addition to that, the above said Software shall have minimum 20% of spare points in each integration parameters. Bidder needs to refer the tender specifications and Quote cost accordingly. Bidder needs to be proposed the ICCC Software with complying of BoQ as well as technical tender specification without any deviation. No further deviation shall be accepted.

1

-

-

... More
FIRE SIGNAGES

-

-

-

... More
FIRE SIGNAGE SYSTEM - The dynamic, maintained emergency exit signage system should be able to be fully integrated with fire alarm systems. 1. Recessed Mounting Type 2. Continously provides illumination through mains power supply 3. As per IS 9583-1981 4. Fully dynamic, maintained emergency exit signages with three states: passive, green arrow and red cross; 5. Styling provided by the adaptive / dynamic LED 3PA Blade technology 6. Self-contained with 4-cell, 4.8v (total) NiMH battery pack 7. Rechargeable battery upto 120 Minutes backup 8. Suitable for 230V & for different types of exit Facia (size 300L * 150 Ht mm) 9. LED Life : 36,000 + hours 10.With NO & NC contacts for FAS integration

-

-

-

... More
Supplying, installation, testing and commissioning of DYNAMIC SIGNAGE " FIRE EXIT " (BATTERY BACKED SIGNAGE) - SINGLE SIDE - FOR FIRE EXIT DOORS - 150*300mm

35

-

-

... More
Supplying, installation, testing and commissioning of DYNAMIC SIGNAGE " FIRE EXIT " (BATTERY BACKED SIGNAGE) - DOUBLE SIDE - 150*300mm

333

-

-

... More
Supplying, installation, testing and commissioning of " EXTINGUISHER Signages - Autoglow, with SS finish suspension chains (Autoglo signages, size 150 x 300) - double side

285

-

-

... More
Supplying, installation, testing and commissioning of " MCP Signages - Autoglow, with SS finish suspension chains (Autoglo signages, size 150 x 300 - double side

108

-

-

... More
Supplying, installation, testing and commissioning of " FIRE HYDRANT Signages - Autoglow, with SS finish suspension chains (Autoglo signages, size 150 x 300 - double side

92

-

-

... More
Signage with printed "IN CASE OF FIRE, USE STAIRS UNLESS INSTRUCTED OTHERWISE" of 1.25cm height letters in red with white back ground. The size of the board shall be 25cm x 30 cm and shall be fixed at the height of 2 mts from finished floor.

32

-

-

... More
Floor identification signage (i.e., GROUND FLOOR etc.) at each stair enclosure on every floor, indicating the floor number in words, lettering size shall be 7.5 cm with contrasting colour from back ground. Size shall be 15cm x 30cm.

30

-

-

... More
Action by Security / Reception signage - On 3mm thick "Opaque" PVC foam board of computerised cut, PVC non-reflective self adhesive vinyl painted foam board of 750 x 450mm. Text in the signage shall be both in English & the local language.

2

-

-

... More
Providing & installing in position the fire safety plan to a recommended scale & at suggested locations. Safety plan shall be with acrylic sheet & 6nos of SS studs for "A2" size. It should have braille and raised letters as per requirements

2

-

-

... More
Supplying, installation, testing and commissioning of Fire Evacuation Route Map as per following specification Evacuation plan shall be glow in dark. A2 size with 5mm thick rear & 3mm thick front acrylic cover including wall mount supports.

53

-

-

... More
GAS SUPPRESSION SYSTEM

-

-

-

... More
SITC of CCOE (PESO )Approved NOVEC1230 or FK-5-1-12 or equivalent Seamless Cylinder and Valve Assembly, of suitable capacity at 0.7 filling ratio or as specified by manufacturer, OEM Factory filled with NOVEC1230 Suppression Liquid, pressurised to 25 bar - 120 l/140 tr, UL/FM/ Vds Approval is required for the system & COmponents used in NOVEC 1230 System or equivalent .(Main Bank 03 Nos + Reserve Bank-03 Nos) cylinder shall be supplied with required mounting Bracket Assembly complete with C Channel Stand and Supports for above Cylinder to be provided.

6

-

-

... More
Pressure Guage +Low pressure supervisory switch

6

-

-

... More
NOVEC1230 or FK-5-1-12 or equivalent gas

396

-

-

... More
SITC OF Electric Control Head operated electrically from the Detection & Control System

6

-

-

... More
SITC of or locally with a manual lever on the control head-Manual Actuator

6

-

-

... More
SITC of Manifold Supervisory Switch for indication of discharge of system

3

-

-

... More
SITC of Flexible Discharge Hose for cylinders

6

-

-

... More
SITC of Nozzles, 360 Deg / 180 Deg Throw, selection as per approved hydraulic flow calculations.

8

-

-

... More
Wall mount kit for ABOVE cylinders

6

-

-

... More
SITC of Warning Plate "THIS ROOM IS PROTECTED BY NOVEC1230" (for use outside room)

3

-

-

... More
SITC of Warning Plate "THIS ROOM IS PROTECTED BY NOVEC1230" (for use inside room)

3

-

-

... More
SITC of NOVEC Piping, Sch 40 MS ; ASTM A106 Gr B, as per flow calculations for the specific hazard volume. Including necessary pressure tests for pipes (ICCC Server & UPS room)

3

-

-

... More
SITC of Manual Abort Station

6

-

-

... More
SITC of Manual Gas Release Station (Multi action)

3

-

-

... More
SITC of Gas Release and builtin 4zone conventional fire alarm panel (UL LISTED Only) With monitored Power supply and Fittings Power supply units shall be with battery backup of 12hrs for gas release panel & Hooter

3

-

-

... More
Supplying,installation, testing & Commissioning of smoke detector with builtin LED and mounting base complete with all connections etc.as required.

12

-

-

... More
Supplying, installation, testing & commissioning response indicator on surface/recess MS box having two LEDs metallic cover complete with all connections etc. as required.

12

-

-

... More
SITC of 24 VDC operated Signages for "Evacuation" and "No entry" inside and outside the protected enclosure, 1 no. each type for every room. Shall be Powered from Gas Release Panel.

6

-

-

... More
Supplying,installation,testing & Commissioning fire alarm sounder with facility to make announcement ,mounted in A.B.S box with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc.complete as required.

6

-

-

... More
Supplying & laying of 2x1 .5 sqmm fire alarm armoured cable, 600 / 1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.

150

-

-

... More
Conducting 'room integrity' test using door fan test methodology. This test should use small pressure differentials between the enclosure and surrounding areas by locating the fan equipment in SERVER & UPS/Battery room doorway. Pressure and airflow measurements to be taken, from which the leakage characteristics of the enclosure to be established. The predicted retention time to be calculated from these leakage characteristics and the enclosure and extinguishing system data. The door fan test methodology should be in accordance with the general requirements specified in BS 5306, BS:ISO 14520, NFPA 12A, NFPA 2001 and the BFPSA Code of Practice for Gaseous Extinguishing Systems. Vendor to conduct detailed visual check to ascertain readiness of the room for test. During test, if any leak found the same shall be attended by Civil vendor. After rectification, the test has to be repeated till successful completion.

3

-

-

... More
CEILING MOUNTED FE-36 FIRE EXTINGUISHER SYSTEM

-

-

-

... More
FE36 Automatic ceiling Mounted Clean agent Extinguisher - 5 Kg with Ceiling mount accessories including nozzle(57 deg), pressure guage. ISI approved

45

-

-

... More
LIFTS

-

-

-

... More
1. Design, manufacture, supply, delivery at site including transportation upto site, unloading & storing at site , handling, installing, testing & commissioning including obtaining statutory approvals / operating license for the following elevators at site as per specifications 2. Procurement of items with aesthetic value and visibility shall be on prior approval of Project Officer in charge for specific area of application 3.Any other items which are not listed above but are essential for completion of the Lift package works and make the system fully functional shall be in Lift Supplier`s scope

-

-

-

... More
Passenger Lifts

-

-

-

... More
Passenger lifts (1360kg) - (Machine room less-MRL with Regenerative Drive) having contract speed of 1.75mps serving different floor in the lift shaft as per detailed specifications enclosed and as under: (i) Load: 1360kg (ii) Capacity: 20 passengers (iii) Speed: 1.75mps (iv) Floor Marking: 10 (P1 , C1 to C9 floors) (v) Travel: As per Arch. Drgs (41.8 mtr) (vi) Stops & opening: 10 stops/10 opens (vii) Controller: ACVVVF-Regenerative Drives (viii) Automatic rescue device complete as required (ix) Operation: 5 Car group passenger lifts with DCS. FULL DOAS system with 2 key pads in GF and 2 key pads in all other floors with voice announcement and braille with disabled friendly feature. (x) Hoistway available: 2700mm W x 2500mm D (xi) Car size : “Max. Car sizes shall be as per NBC 2016” (xii) Type of doors (a) Car Doors: SS Textured Panel (Scratch Proof) (b) Landing doors: SS Brushed Finish .1300mm W x 2300mm H Center Opening . (xiii) Lift Car Finishes: Side & Rear walls - SS Textured Panel (Scratch Proof) Ceiling - SS Brushed Finished Panel with protected LED light of indirect lighting with min.150 Lux at 1 meter above floor level. Rectangular grill in ceiling with Exhaust blower fans covering full length width with overhead ventilation grids for optimum air flow. Noise level of ventilation fan shall be limited with 35dB(A) at 1m distance Flooring - 25mm recess in platform with Granite finish (As per approval from Architect and Engineer in charge) Kick plate shall be as per Panel Finsih with 2-3 inch height. Lift shaft reducing channels to be considered if required. All Finishes shall be to resistant fingerprint marks from constant use for ease cleaning and maintenance. Final finishing selection shall be as per instructions ofProject Officer`s In-charge

-

-

-

... More
Other parameters / requirements should be considered as per detailed specification sheet. All elevators shall be provided with regenerative drives. The regenerative power developed shall be utilised in the elevator system itself. % of energy saving shall be as per OEM design. Bidder to demonstrate the energy saving due to usage of regenerative drives during the commissioning of elevator. Hand rail not less than 600mm long at 900mm above floor level to be fixed adjacent to control panel in lift car. Voice announcement system in the car to announce the position of the lift in the hoistway as the car passes or stops at a floor served by the lift.

5

-

-

... More
Passenger lifts (1020kg) (Machine room less-MRL with Regenerative Drive) having contract speed of 1.0mps serving different floor in the lift shaft as per detailed specifications enclosed and as under: (i) Load: 1020kg (ii) Capacity: 15 passengers (iii) Speed: 1.0 mps (iv) Floor Marking: 05 (B2, B1& Podium1 (P1) TO Podium3 (P3)) (v) Travel: As per Arch. Drgs 13.45 mtr (vi) Stops & opening: 9 stops/9 opens (vii) Controller: ACVVVF (viii) Automatic rescue device complete as required (ix) Operation: Duplex Full Collective (x) Hoistway available: 2300mm W x 2300mm D (xi) Car size :Max. Car sizes shall be as per NBC 2016 (xii) Type of doors (a) Car Door: SS Textured Panel (Scratch Proof) (b) Landing doors: SS Brushed Finish . 1200mm W x 2300mm H, Center Opening . . (xiii) Lift Car Finishes: Side & Rear walls - SS Textured Panel (Scratch Proof) Ceiling - SS Brushed Finished Panel with protected LED light of indirect lighting with min.150 Lux at 1 meter above floor level. Rectangular grill in ceiling with Exhaust blower fans covering full length width with overhead ventilation grids for optimum air flow. Noise level of ventilation fan shall be limited with 35dB(A) at 1m distance

-

-

-

... More
Kick plate shall be as per Panel Finsih with 2-3 inch height. Flooring - 25mm recess in platform with Granite finish (As per approval from Architect and Engineer in charge) Lift shaft reducing channels to be considered if required. All Finishes shall be to resistant t fingerprint marks from constant use for ease cleaning and maintenance. Final finishing selection shall be as per instructions ofProject Officer`s In-charge Other parameters / requirements should be considered as per detailed specification sheet. All elevators shall be provided with regenerative drives. The regenerative power developed shall be utilised in the elevator system itself. % of energy saving shall be as per OEM design. Bidder to demonstrate the energy saving due to usage of regenerative drives during the commissioning of elevator. Hand rail not less than 600mm long at 900mm above floor level to be fixed adjacent to control panel in lift car. Voice announcement system in the car to announce the position of the lift in the hoistway as the car passes or stops at a floor served by the lift.

2

-

-

... More
Service Lift

-

-

-

... More
Passenger lifts (1360kg) - (Machine room less-MRL with Regenerative Drive) having contract speed of 1.0mps serving different floor in the lift shaft as per detailed specifications enclosed and as under: (i) Load: 1360kg (ii) Capacity: 20 passengers (iii) Speed: 1.5mps (iv) Floor Marking: 15 (B2, B1, Podium1 (P1) to Podium3 (P3) & Commercial Floor 1 (C1) to Commercial Floor 9 (C9))Terrace (v) Travel: As per Arch. Drgs (48.6mtr) (vi) Stops & opening: 15 stops/15 opens (vii) Controller: ACVVVF-Regenerative Drives (viii) Automatic rescue device complete as required (ix) Operation: Simplex (x) Hoistway available: 2300mm W x 2800mm D (xi) Car size : “Max. Car sizes shall be as per NBC 2016” (xii) Type of doors (a) Car Doors: SS Textured Panel (Scratch Proof) (b) Landing doors: SS Brushed Finish .1300mm W x 2300mm H Center Opening . (xiii) Lift Car Finishes: Side & Rear walls - SS Textured Panel (Scratch Proof) Ceiling - SS Brushed Finished Panel with protected LED light of indirect lighting with min.150 Lux at 1 meter above floor level. Rectangular grill in ceiling with Exhaust blower fans covering full length width with overhead ventilation grids for optimum air flow. Noise level of ventilation fan shall be limited with 35dB(A) at 1m distance Flooring - 25mm recess in platform with Granite finish (As per approval from Architect and Engineer in charge) Kick plate shall be as per Panel Finsih with 2-3 inch height. Lift shaft reducing channels to be considered if required. All Finishes shall be to resistant fingerprint marks from constant use for ease cleaning and maintenance.

-

-

-

... More
Final finishing selection shall be as per instructions ofProject Officer`s In-charge Other parameters / requirements should be considered as per detailed specification sheet. All elevators shall be provided with regenerative drives. The regenerative power developed shall be utilised in the elevator system itself. % of energy saving shall be as per OEM design. Bidder to demonstrate the energy saving due to usage of regenerative drives during the commissioning of elevator. Hand rail not less than 600mm long at 900mm above floor level to be fixed adjacent to control panel in lift car. Voice announcement system in the car to announce the position of the lift in the hoistway as the car passes or stops at a floor served by the lift.

1

-

-

... More
DUMB LIFT

-

-

-

... More
Dumb Lift having contract speed of 0.75mps serving different floor in the lift shaft as per detailed specifications enclosed and as under: (i) Load: 100kg (min) (ii) Capacity: NA (iii) Speed: 0.75mps (iv) Floor Marking: 5 ( B1, Podium1 (P1) & Commercial Floor 1 (C1) , Commercial Floor 6 (C6),Commercial Floor 8 (C8) ) (v) Travel: As per Arch. Drgs (45.5mtr) (vi) Stops & opening: 5 stops/5 opens (vii) Controller: Gearless Induction Motor (ix) Operation: Simplex (x) Hoistway available: 1400mm W x1100mm D (xi) Car size : As per Manufacturer Standards (a) Car Doors: Aluminium Chequered Plate Ceiling - Aluminium Chequered Plate with protected LED light . All Finishes shall be to resistant fingerprint marks from constant use for ease cleaning and maintenance. Final finishing selection shall be as per instructions of Project Officer`s In-charge Other parameters / requirements should be considered as per detailed specification sheet.

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.