Tamilnadu Cooperative Milk Producers Federation Limited Tender
Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.
Tamilnadu Cooperative Milk Producers Federation Limited Tender
Civil And Construction
Building Construction
Eprocure
Opening Date14 Mar 2024
Closing Date23 Apr 2024
Tender Amount₹ 3,00,00,000
Costs
EMD
₹ 3,00,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_TCMPF_448713_1Bid Award Id
ViewTender No
2941/Engg.2/2024Tender Authority
Tamilnadu Cooperative Milk Producers Federation Limited ViewPurchaser Address
-Website
http://TamilnaduCooperativeMilkProducersFederationLimited
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Dismantling of RCC wall, floor and clearing the debris away from site etc., complete as directed by the federation engineers .
25
-
-
Earth work excavation for foundation depositing the earth on bank with initial lead of 10m & initial lift of 2m in Sand, silt or other loose soil, wet sand or silt not under water, light black cotton soil sandy loam and ordinary soil including excavated earth etc Complete as directed by the federation engineers and as per standard specification.
560
-
-
Expansion Joint: Providing expansion joint in RCC floor slab for 12.5mm width using polysulphide as sealent on the top and bottom for a federationh of 7.5mm each and packing the inner space using compressible non-absorbent filler materials including cost of labour for cutting and fixing filler materials and laying polysulphide sealent with necessary spatula etc., complete complying with standard specifications and as directed - for RCC FLOOR SLAB
25
-
-
FOR RCC TWIN COLUMNS
35
-
-
FOR RCC ROOF SLAB
12.5
-
-
Supply and filling with clean M- sand for foundation and basement etc Complete as directed by the federation engineers and as per standard specification
16
-
-
Supply and filling with M-sand gravel mix 1:3 ratio etc Complete as directed by the federation engineers and as per standard specification (BASEMENT)
545
-
-
Plain Cement concrete 1:5:10 (one part of cement and five part of sand and ten part of aggregate) 40mm size HBG stones for foundation including de-watering if found necessary and laid in layer of not more than 15cm thick etc, Complete as directed by the federation engineers and as per standard specification.
40
-
-
Plain Cement concrete 1:2:4 ,20mm size HBG stones for foundation including de-watering if found necessary and laid in layer of not more than 15cm thick etc, Complete as directed by the federation engineers and as per standard specification.
87
-
-
Supply, erecting steel centering using M.S sheet of size 90x60cm and B.G 10 gauge stiffened welded with MS 'L' angle 25x25x3mm laid over silver oak/country wood joist of size 10x6.5cm spaced at about 90cm center to center spacing etc complete and removing the same after a specified period etc, complete as directed by the federation engineers and as per standard specification.
Upto basement.Plain Surface
335
-
-
Upto basement. Column Surface
170
-
-
For Above Basement 0 to 3.30m.Plain Surface
240
-
-
For Above Basement 0 to 3.30m Column Surface
175
-
-
3.30m to 4.30m - Column Surface
53
-
-
4.30 to 5.30 m - Plain Surface
700
-
-
4.30 to 5.30 m - Column Surface
53
-
-
5.30 to 6.30m - Column Surface
50
-
-
6.30 to 7.30m -Column Surface
50
-
-
7.30 to 8.30 m - Plain Surface
240
-
-
7.30 to 8.30 m - Column Surface
50
-
-
8.30 to 9.30 m -Plain Surface
700
-
-
8.30 to 9.30 m -Column Surface
50
-
-
9.30 to 10.30 m -Column Surface
22
-
-
Providing and laying of Reinforcement Cement concrete 1:1.5:3 (one part of cement and one and half part of sand and three part of aggregate)Using 20mm size HBG stone jelly including curing, labour charges etc complete as directed by the federation engineers and as per standard specification.
Upto Ground Level - Upto Basement
138
-
-
Above Basement upto 4.50m ht LVL
67
-
-
Above 4.50m to 9.00m height (FF LVL)
235
-
-
Supply, fabricating and placing in position of steel rods for RCC works including binding wire(Black -18G) and Fitter (Pipe laying / Bar bending) I class . etc complete as instructed by the federation engineers and as per standard specification.
545
-
-
Brick work in CM 1:5 (one part cement and five parts sand) using second class ground moulded chamber bricks of size 9”x 4½”x 3” to line and level including necessary curing ,Bricks II class ground mould chamber burnt, labour charges, lifting charges etc. complete as instructed by the federation engineers and as per standard specification.UP TO Basement
55
-
-
Above Basement upto 4.50m ht LVL
75
-
-
Above 4.50m to 9.00m height (FF LVL)
65
-
-
Brick partition walls of 11.50cm thickness using best quality II class Ground moulded chamber burnt bricks of size 9" x 4-1/2" x 3" in Cement Mortar 1:3 (One Cement and Three M-Sand) using hoop iron reinforcement if found necessary including curing etc. complete and as directed by the federationofficers. Ground Floor
15
-
-
First floor
15
-
-
Plastering with cement mortar 1:5 (one part of cement and five parts of sand) 12mm thick including labour charges scaffolding, neatly finishing and curing etc complete as directed by the federation engineers and as per standard specification. (INNER PLASTERING)
1520
-
-
Ceiling plastering for the exposed surfaces of roof slab bottom, beam, sunshade etc., with CM 1:3, 10mm thick including labour charges scaffolding, neatly finishing and curing etc, complete as directed by the federation officers and as per standard specification.
2460
-
-
Plastering with cement mortar 1:5 (one part of cement and five parts of sand) 20mm thick including labour charges scaffolding, neatly finishing and curing etc complete as directed by the federation engineers and as per standard specification. (EXTERNAL PLASTERING)
1320
-
-
Painting the new plastered wall surfaces with 2 coats of ACE paint of approved quality and colour over priming coat including Wall Primer,ACE paint for wall surfaces and labour charges paint over a priming coat etc, Complete as directed by the federation engineers and as per standard specification.(Interior)
3990
-
-
Painting the new plastered wall surfaces with 2 coats of ACE paint of approved quality and colour over priming coat including Wall Primer,ACE paint for wall surfaces and labour charges paint over a priming coat etc, Complete as directed by the federation engineers and as per standard specification.(Exterior)
1430
-
-
Supply & paving of Polyurethane Floor (PU) Topping flooring (3-6mm) with smooth finish surface with base screed and labour charges etc, Complete as directed by the federation engineers and as per standard specification.
85
-
-
Supply and laying of 18-20mm thk granite tiles (jet black/white design super fine polished with machine cut edges using CM 1:3, 20mm thick including pointing with colour cement etc, Complete as directed by the federation officers and as per standard specification(Color approved by federation Engineer)
150
-
-
Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase near wet riser using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick will be provided with tubular supports made of 304L Grade Stainless Steel pipe of 25mm dia of 1.60mm thick welded to the railing. The supports will be grouted into the wall and provided with 93.00mm thick Stainless Steel circular base plate of 304Grade. The rate shall included for grouting into concrete with necessary supporting arrangements the hand rail in floor polishing buffing, bonding, cutting, grinding, conveyance, welding charges, electrical charges, etc. complete
35
-
-
ABS DOOR / EQUIVALENT
Specification: Providing of 35mm thick factory made pre-laminated ABS (Acrolynitrile Butadiene Styrene) Door Shutter moulded in different designs, consisting of all round frame made out of water proof solid foam PVC bar of size 20 x 32mm, reinforced by 32 x 32mm - 2 Nos., for vertical made out of LVL (Laminated Veneer Lumber), core material of 32mm thick high density craft paper honey comb board, sandwiched on both sides with pre-laminated ABS sheet thickness of 1.5mm.PVC edge banding of size 0.45mm on the vertical sides.Hardware made out of steel coated butterfly hinges - 3 Nos., for each shutter and ISI make SS round lock complete for finished item of work, complete complying with the standard specification. The door shutter and frame should be got approved from the federation before use on work Plain Pre-laminated Door
9
-
-
Fabricating supplying and fixing in position of aluminium powder coated approved colour matt finish half panelled with 12mm thick bothside prelaminated partile board at bottom and half glazed using 5.50mm thick Plain glass at top double leaves door with 0.3m fixed ventilator at top. The outer frame shall be with aluminium box section and with the Shutter frame made of section with Vertical & Top rail Bottom rail Lock rail Alu. Clips: Alu. Handle: 100x30mm and Inner Frame of section and necessary accessories such as aluminium clips, rubber beading PVC felt, handle for a length of shutter (both sides), locking arrangements, furniture fittings such as aluminium tower bolts-250x12mm - 2Nos, aluminium tower bolt 200x12mm - 1No, aluminium door stopper with rubber bush - 2Nos ., lock-1No.,Hydraulic Door closer as per BIS standards including cost of all materials, labour charges and power consumption charges required for fabrication including chipping dismantling and making holes to the required extent in RCC in column/beam/masonry with power drill wherever neccessary and redoing the demaged portion to the original condition after fixing etc. complete.All Aluminium section shall be for glazing portion Aluminium sections and furniture fittings shall be got approved by the federation incharge.
18
-
-
Fabricating Supplying and fixing in position of Aluminium powder coated natural colour matt finish Two/three panels sliding type window in all floors with aluminium sections of the Outer frame: Centre mullions:Shutter frame : Aluminium clips:with neccessary accssories such as rubber beadings, special hinges, handle including supplying and fixing 4mm thick plain glass including cost of all materials, labours, power consumption required for fabrication, drilling holes in RCC column slab, masonry walls wherever necessary with power drills to the required extent and make good to the original conditons after fixing and also as directed. All the Aluminium sections are to the anodised with matt finish etc.Complete.
110
-
-
Fabricating Supplying and fixing in position of Aluminium powder coated natural colour matt finish fixed glass fully glazed type partition in all floors with aluminium sections of the Outer frame: Centre mullions:Shutter frame : Aluminium clips:with neccessary accssories such as rubber beadings, special hinges, handle including supplying and fixing 4mm thick plain glass including cost of all materials, labours, power consumption required for fabrication, drilling holes in RCC column slab, masonry walls wherever necessary with power drills to the required extent and make good to the original conditons after fixing and also as directed. All the Aluminium sections are to the anodised with matt finish etc.Complete.
95
-
-
Fabricating Supplying and fixing in position of Aluminium powder coated colour matt finish louvered ventilator in all floors with aluminium sections of the Outer frame: Centre mullions:Shutter frame : Aluminium clips:with neccessary accssories such as rubber beadings, including supplying and fixing 4mm thick plain glass including cost of all materials, labours, power consumption required for fabrication, drilling holes in RCC column slab, masonry walls wherever necessary with power drills to the required extent and make good to the original conditons after fixing and also as directed.
4
-
-
Fibre mesh insect proof screen net for windows in all floors including cost of all materials, labours, power consumption required for fabrication, masonry walls wherever necessary with power drills to the required extent and make good to the original conditons after fixing and also as directed by the Federation Engineers.
180
-
-
Solid PVC door shutters using 19 Gauge 19mm MS square tubes for style and outer frames 15mm MS square tubes for top lock and bottom rails. The steel tubes shall be covered with 5mm thick solid PVC sheet. Shutter using 5mm thick solid PVC sheeets for panelling shall rigidly fixed in position including nedessary furniture and fittings. The over all size of styles shall be 50mmx30mm. The overall size of top rail, Lock rail and bottom rail shall be 75mmx30mm. The over all size of frames shall be 50mmx45mm, with suitable rebate for housing the shutter. Solid panel PVC door with Frame.
6.3
-
-
Providing Weathering course in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no sand to be used) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the federation officers.
55
-
-
Finishing the top of roof with one course of machine pressed tiles of size 230mm x 230mm x 20mm of approved quality set in Cement Mortar 1:3 (One Cement and Three Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full federationh of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete as directed by the federation officers
475
-
-
Supplying and fixing in position best approved of BIS quality PVC rain water down fall 110mm dia pipes having a pressure of 4 kg. / sq.cm including cost of necessry PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of "U" clamp at the centre of the pipe line in addition to those for more than 3.0 metre pipe length, etc., complete complying with standard specification. Finolex or equivalent
105
-
-
Supply and fixing 100mm aluminium anodised natural coated matt finish skirting for side wall surfaces in all floor surfaces etc.,as instructed by the federation officers with standard specification.
320
-
-
Providing and fixing of Aluminium Composite Panel
(ACP) 4 sided having 50 x 25 x 1.50mm frame work
vertical and horizontals out of specially designed
extruded sections withstand wind pressure of 180
Kg/sq.m and fabricated fixed at all level elevation and heights. The extruded section cutting and fixing
required space extruded section shall be of 6063 and alloy of BSH 9 confirming T is – 63400 rate shall
included to fix the main frame with necessary clamps, fasteners, bolt nuts etc. The main frame of extruded section shall be of 22843 & 22739 (H9) grade conforming to BS 4174 (or) IS 8147. Rate shall
included 4mm thick ACP sheet (0.25 + 3.5 + 0.25)
alstrong or equivalent fixing with spacer tape and the ACP sheet bounded with special type structural sealantof dow corning 789 or equivalent in dust free
conditions the gaps between ACP sheet to be filed with whether sealant and backer rod or 12mm foam sheet to ensure water and air tightness in all complete complying with standard specification as directed bythe federation officer
80
-
-
Structural Glazing:
Providing and fixing structural glazing fabricated from roll formed sections made of galvanized steel colour coated(Base steel as per IS 513 of ‘D’ quality, galvanized as per IS 277 with Zinc of 120 grams / sqm.) with total coated thickness of 0.72mm. The glass holding section made of 304 grade SS of 0.6mm thick. Galvanized steel sections are to be
used as stiffeners inside the colour coated steel / powder coated sections as per the design requirement. Design calculations are made to suit wind pressures as given in IS 875.
Paint specifications: Primer coat with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with alkyd backer of 5-7 microns or powder coated with pure polyester powder upto 50-60 microns thick.
Dimensions: The section should be of 37 x 53mm for frame vertical, 37 x 53mm for frame horizontal section and section for reinforcement should be of 31 x 55mm. glass holding section should be of 37 x 37mm for top and bottom grids in between should be of 37 x 18mm.Accessories: Brackets made of CRCA powder coated /electro plated should be used to fix vertical at top and bottom and vertical to slab as per site requirement.
Polyurethane brackets should be used to connect
horizontal section to vertical sections.
Silicone: Natural cure, with good UV resistance to be used.
The above frame should be fixed to brick / concrete
masonry by using nylon self–expanding cap and
driving MS electro plated 80mm long screws into the
caps through frames.
Glass: 5mm reflective Saint Gobain OR equivalent.
50
-
-
Glazing system door patch fittings:
Providing and fixing Glass door patch fittings hardwares using floor spring, patch top & bottom fittings with H type handle (SS) with glazing clips, rubber, patch dock stopper etc., complete. (Make Dorma/geze/ozone or other equvalent) Make should be got approved by the Federation Officials.
2
-
-
Supply & fixing PVC false ceiling 2'x2' grid frame using with necessary L, wall angle, Main & cross Tee's, rawl plugs with screws etc.,Complete as directed by the federation officers and as per standard specification. Ceiling height sholud be maintained as directed by federation.Engineers. inside of lab area
680
-
-
Supply & fixing Gypsum Design false ceiling 10 to 12mm thick using with necessary grid frame L, wall angle, Main & cross Tee's, rawl plugs with screws etc.,Complete as directed by the federation officers and as per standard specification. Ceiling height and design sholud be maintained as directed by federation.Engineers. inside of lab area
75
-
-
Supply, fabrication & fixing of MS safety grill works for window the cost including wall drill cutting, mortar packing grouting primer & enamel painting, cost and all conveyance charge including labour charges etc.,as directed by the federation engineers and as per standard specification.
1540
-
-
Supplying and fixing in position of Powder coated galvalume colour sheet of 0.47mm thickness with necessary bolts, nuts and washers, metal screws etc. complete with standard specification and as directed by the departmental officers. (Tata , jindal or Equivalent)
96
-
-
Supply and fixing 2 inch dia GM non return wheel Valve including fixing in position etc complete as directed by the federation engineers and as per standard specification.
2
-
-
Construction of manhole chambers of size of inner dimension 0.60 x 0.60 and 0.45 m to 1.00 m depth over a bed of cement concrete 1:5:10, 100 mm thick using 40 mm metal and side wall with brick work in CM 1:5 (One part cement and five parts sand) 23 cm thick plastering inside with CM 1:3, 20 mm thick and outside with CM 1:5, 12 mm thick and top with RCC bed concrete of 100 mm thick for fixing heavy duty CI chamber cover of size 60 x 60 cm with rims , providing saddles in CC 1:2:4 and finishing inside smooth with cement slurry at 2.20 kg/m² etc., complete as directed by the Federation officers and as per standard specifications.
5
-
-
Supply and fixing of PVC tank of approved make as instructed federationofficial etc., complete as directed by the federation officers and as per standard specifications
3000
-
-
Supplying and fixing of 40 DIA-CWS (UPVC) including labour charges, etc complete as directed by the federation engineers and as per standard specification.
77
-
-
Supplying and fixing of 32 DIA-CWS (UPVC)including labour charges, etc complete as directed by the federation engineers and as per standard specification.
39
-
-
Supplying and fixing of 20 DIA-CWS (UPVC) including labour charges, etc complete as directed by the federation engineers and as per standard specification.
69
-
-
Supplying and fixing of 150 DIA-CWS (PVC) including labour charges, etc complete as directed by the federation engineers and as per standard specification.
25
-
-
Supplying and fixing of 110 DIA-CWS (PVC) including labour charges, etc complete as directed by the federation engineers and as per standard specification.
15
-
-
Supplying and fixing of 75 DIA-CWS (PVC) including labour charges, etc complete as directed by the federation engineers and as per standard specification.
30
-
-
Wash Hand Basin of size 550mm x 400mm with all accessories such as Cast Iron Brackets, 32mm dia CP Waste Coupling, Rubber Plug and Chain, 32mm dia 'B' Class GI Waste Pipe, 15mm dia GM Wheel Valve, 15mm dia Nylon Connection, 15mm dia Brass Nipples, 15mm CP Pillar Tap(White with Pedastal) etc., (Parryware/Cera or Equvalent)
2
-
-
European Water Closet with "P" or "S" Trap withDouble Flapped Seat and Seat Cover with Brass Hinges and 10 litre capacity Porcelain Low Level Flusing Tank with all internal fittings- color. (Parryware/Cera or Equvalent)
2
-
-
Supplying and fixing in positon Indian Water Closet (Oriya type) of size 580 x 440mm white glazed earthern ware of approved quality and brand with "P" or "S" trap conforming to BIS with crushed stone sandcushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One lime, Two crushed stone sandand Five brick jelly) 100mm thick and finishing the top to the required slope and including giving necessary connection to PVC pipes(Parryware/Cera or Equvalent)
2
-
-
Supplying and fixing of 15 mm SS BIP COCK including labour charges, etc complete as directed by the federation engineers and as per standard specification.(Parryware, Waterman ,Neycer or Equivalent)
4
-
-
Supplying and fixing of ANGLE COCK including labour charges, etc complete as directed by the federation engineers and as per standard specification. ( Parryware, Waterman ,Neycer or Equivalent)
4
-
-
Supplying and fixing of PILLAR COCK including labour charges, etc complete as directed by the federation engineers and as per standard specification. ( Parryware, Waterman ,Neycer or Equivalent)
4
-
-
Supplying and fixing of UPVC BALL VALVE including labour charges, etc complete as directed by the federation engineers and as per standard specification.( Parryware, Waterman ,Neycer or Equivalent)
4
-
-
Supplying and fixing of HEALTH FAUCET including labour charges, etc complete as directed by the federation engineers and as per standard specification.( Parryware, Waterman ,Neycer or Equivalent)
2
-
-
Supplying and fixing of WALL MIXTURE including labour charges, etc complete as directed by the federation engineers and as per standard specification.( Parryware, Waterman ,Neycer or Equivalent)
2
-
-
Supplying and fixing of SS FLOOR TRAP 100x75 mm including labour charges, etc complete as directed by the federation engineers and as per standard specification. ( Parryware, Waterman ,Neycer or Equivalent)
8
-
-
Supplying and fixing of SS Towel Rack with Lower Hanger including labour charges, etc complete as directed by the federation engineers and as per standard specification.
4
-
-
Supplying and fixing of 2.0 HP Monoblock pump including labour charges, etc complete as directed by the federation engineers and as per standard specification.(SUGUNA, CRI, Kirloskar,Crompton or Equivalent)
1
-
-
Wiring with 2x1.5Sqmm. (22/0.3) PVC insulated unsheathed SC Cu. conductor of 1100V grade in suitable PVC rigid pipe concealed in wall & ceiling with PVC accessories with 1No. 1 Module metal flush type box with suitable cover plate and 1 No. 6A one way SP 1 Module switch in flush with wall for making good of the concealed portion with suitable colour for PVC concealed light point. (Box, cover plate and switch should be Legrand) (5 Points Per Coil)
110
-
-
Wiring with 2x1.5Sqmm. (22/0.3) PVC insulated unsheathed SC Cu. conductor of 1100V grade in suitable PVC rigid pipe concealed in wall & ceiling with PVC accessories with 1No. 1 Module metal flush type box with suitable cover plate and 1 No. 6A one way SP 1 Module switch in flush with wall for making good of the concealed portion with suitable colour for PVC concealed light point. (Box, cover plate and switch should be Legrand)(6 Points Per Coil) (For Rooms like Bath , Toilet,& Pump room etc..)
85
-
-
Wiring with 2x1.5Sqmm. (22/0.3) PVC insulated unsheathed SC Cu. conductor of 1100V grade in suitable PVC rigid pipe concealed in wall & ceiling with PVC accessories with 1No. 3 Module metal flush type box with suitable cover plate and 1 No. 6A one way SP 1 Module switch&2 module 6A 5 pin universal socket with continuous earth wire connection of 1 sq.mm copper wire in flush with wall for making good of the concealed portion with suitable colour for concealed PVCPlug point. (Box, cover plate and switch should be Legrand)
6
-
-
Supply and fixing of 4feet Regal battern (SBT) suitable for 1x18/22W LED tube double side with 18W Crystal Glass LED Tube light (double side connection) with co extruded polycarbonate body, envirmental friendly, energy efficient on wall or ceilinh with PVC unshedthed copper leads from terminals to the fitting and testing in good condition (Havells / Model: LHLDDAXEUL8Z018)/Philips / Crompton)
15
-
-
Supply and fixing of AC high speed Ceiling fan complete 1200 mm (48") with stepped electronic 300W regulator with 300mm down rod on the existing clamp (Crompton high speed fan)
20
-
-
Supply and fixing of 400 mm sweep (light duty) wall mounted fan complete without provision of holes in the wall
15
-
-
Supply and fixing of 1 No. 48W high power LED green line smart luminaries products have a life span of 40,000 burning hours street light fitting with 19mm dia GI pipe (Class ‘B’) with 1No. 19mm GI Bend complete on the existing wall with 16A aerial fuse unit on MS plate with PVC unsheathed copper leads with MS clamps & aluminium painting (Havells/ Crompton / Philips)
5
-
-
Supply & fixing of 1 No. of 6 module metal flush type box with suitable cover plate comprising of 1 Nos. 16A one way SP 1 module switch with 1Nos.16/ 6A 2/3 pin combined socket shuttered in flush with wall with necessary connections (Box, cover plate and switch should be Legrand )
52
-
-
Supply & fixing of 1 No. of 12module metal flush type box with suitable cover plate comprising of 3Nos. 6A one way SP 1 module switch with 3Nos. 6A 2/3 pin combined socket shuttered 2 module in flush with wall with necessary connections for computer plug boards. (Box, cover plate and switch should be Legrand ) [ For Computer plug board]
5
-
-
Supply & run of 2 of 2.5sqmm (36/0.3) PVC insulated SC unsheathed cu. conductor of 1100V grade in suitable PVC rigid pipe on conceled & ceiling with continuous earth wire connection of 1.5sqmm (22/0.3) PVC insulated SC unsheathed cu. conductor of 1100V grade and making good (For each Circuit Connection of Computer Plug)
75
-
-
Supply and fixing of 25 A flush type wall socket with 25 A SP MCB in suitable sheet steel enclosure like Havells / equivalent in flushwith wall with earth connection.(For AC Plug)
6
-
-
Supply and fixing of 12 way single pole and neutral MCB sheet steel enclosure Distribution board with Double Door and 1No32 Amps DP MCB as incoming and 10 Nos 10 Amps SPMCB as outgoing in flush with wall and making good of the concealed portion with earth connection only. The MCB DB and MCB's should be Like Hager / Legrant / euqivelant make(Lighting Distribution for All rooms - 4 Nos and 2 Nos separately for MRAC and IoT )
2
-
-
Supply and fixing of 12 ways Vertical Triple pole and neutral MCB distribution board made out of sheet steel / alu. rail complete with bus bar arrangements incorporating the following controls with double door arrangements [IP 42 Metal door of Legrand] in flush with wall & making good of the concealed portion with earth connection.
(1) 63A 4PMCB Isolator as Incoming: 1 No. 2)40A 4PMCB as outgoing :3 Nos. 3)32A DPMCB as outgoing :13 Nos.( MCBDB, Isolator, MCB should be Legrand ) (For Overall conrol PDB and overall control for LDB )
1
-
-
Supply and fixing of 8 ways Triple pole and neutral MCB distribution board made out of sheet steel / alu. rail complete with bus bar arrangements incorporating the following controls with double door arrangements [IP 42 Metal door of Legrand] in flush with wall & making good of the concealed portion with earth connection.
(1) 40A 4PMCB as Incoming: 1 No. 2) 32A DPMCB as outgoing :12 Nos. ( MCBDB, Isolator, MCB should be Legrand ) (For AC plugs,15A Plug power DB in GF and FF)
1
-
-
Supply & run of 2 of 4sqmm (56/0.3) PVC insulated SC unsheathed cu. conductor of 1100V grade in suitable PVC rigid pipe on conceled & ceiling with continuous earth wire connection of 1.5sqmm (22/0.3) PVC insulated SC unsheathed cu. conductor of 1100V grade and making good (for AC Plug and 15A Plug set)
220
-
-
Supply and run of 2 of 6 sqmm (84/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100V Grade in suitable PVC rigid pipe concealed in wall and ceiling with contiinuous earth wire connection 1.5sqmm (22/0.3) PVC insulated SC unsheathed cu. conductor of 1100V grade and making good of the concealed portion with suitable colour
120
-
-
Supply and run of 4 of 4 sq.mm (84/0.3) PVC insulated SC unsheathed Cu Conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection by 14 SWG TC wire and making good of the concealed portion with suitable colour (For 1No 32A 4P MCB in MRAC)
10
-
-
Supply and run of 4 of 6 sq.mm (84/0.3) PVC insulated SC unsheathed Cu Conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection by 14 SWG TC wire and making good of the concealed portion with suitable colour (From Master control DB to Power DBs in GF and FF)
55
-
-
Supply and run of 4 of 10 sq.mm (140/0.3) PVC insulated SC unsheathed Cu Conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection by 14 SWG TC wire and making good of the concealed portion with suitable colour (From Panel board to Power DBs )
10
-
-
Supply and clamping of 3½ X 120 sq mm PVC armored LTUG cable in 65 mm GI pipe(class-B) on post or on wall with suitable MS Clamps
75
-
-
Supply and fixing of brass cable gland for 3½ X120 Sq.mm LTUG armoured cable with earth connection
12
-
-
Supply and providing cable end termination of 3 1/2 x120 sqmm PVC LTUG Aluminium armoured cable with necessary aluminium cable sockets by crimping etc. with electrical connection complete
2
-
-
Earthing as per the ISI specification with an earth electrode of 2.1mt class 'B' GI pipe of dia not less than 40mm, with copper earth plate of size 125mm x 50mm x 6mm, with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry .
1
-
-
Supply and run of 1of No 8 SWG GI wire in suitable PVC rigid pipe on wall and ceiling for earth connection.
10
-
-
Supply and fixing acrylic foam name board with LED light fiitings with necessary clamp fixing, with wiring the cost including all conveyance of manpower with all floor levels etc., complete as directed by the federation engineers and as per standard specification.
1
-
-
Supply & fixing 22W LED 4000K 2 x 2 Square Type Recessed Fitting with LED necessary clamp fixing, with wiring the cost including all conveyance of manpower with all floor levels etc., complete as directed by the federation engineers and as per standard specification. (Havells/ Crompton / Philips)
60
-
-
Supply & fixing 22W LED Round Type Recessed Fitting with LED necessary clamp fixing, with wiring the cost including all conveyance of manpower with all floor levels etc., complete as directed by the federation engineers and as per standard specification. (Havells/ Crompton / Philips)
20
-
-
Supply and laying of 63mm thick high strength type of interlocking paver block of approved colour made up of designed concrete mix 1:2:4 using 10 to 12mm size HBG stone jelly in required shapes and size having minimum compressive strength of 40 N/mm2 to be laid in flurrying bone pattern with approved non-sticking surface at top. The rate is inclusive of leveling the site, providing sand cushion 100mm thick, compacting with power compactor and sweeping the sand grouting and also inclusive of transportation charges, loading unloading and Labour charges for laying the paver block etc., complete as directed by the federation officers and as per standard specifications
280
-
-
Plain Cement concrete 1:4:8 (one part of cement and four part of sand and eigth part of aggregate) 40mm size HBG stones for foundation including de-watering if found necessary and laid in layer of not more than 15cm thick etc, Complete as directed by the federation engineers and as per standard specification. Upto Ground Level - Upto Basement
23
-
-
Providing and laying of Reinforcement Cement concrete 1:2:4 Using 20mm size HBG stone jelly including curing, labour charges etc complete as directed by the federation engineers and as per standard specification.
Upto Ground Level - Upto Basement
18
-
-
Supply, fabricating and placing in position of steel rods for RCC works including binding wire(Black -18G) and Fitter (Pipe laying / Bar bending) I class . etc complete as instructed by the federation engineers and as per standard specification.
11.7
-
-
Supply, fabrication & installation of Main gate grill MS fabrication works and truss works including one coat primer and two coats Enamel painting as directed by the federation engineers and as per standard specification.
1350
-
-
GST (Note: The tenderer should quote the amount towards Goods and Service tax (GST) in the appropriate columns in terms of percentage (%). If not quoted, it will be considered that the rate quoted is inclusive of GST.)
1
-
-
Evaluation Notes How It Works ?