Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.

Tamil Nadu Urban Habitat Development Board - TNUHDB Tender

Works
Civil And Construction
Civil Works Others
Machinery and Tools
Eprocure
Opening Date20 Nov 2024
Closing Date4 Dec 2024
Tender AmountRefer Documents 
Notes
Download

Costs

Summary

Tnuhdb /420/ Hd / Se East-ii / 2024

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply, Installation and Testing of Breake coil unit 110v DC work as per the following specification. Coil: 110 VDC Peak Current: 247 Amps Holding Voltage: 110 VDC etc., complete in all respects directed by the departmental officers.

29

-

-

... More
sSupply, Installation and Mother board work as per the following specification. Elevator Load Capacity 680kg Persons 6-10 input voltage:24v Speed 1.00m/s Control Type Relay Control Lift Mechanism center opening Use of Occasions Indoor Type etc., complete in all respects directed by the departmental officers.

10

-

-

... More
Supply, Installation and Testing of ARD Board as per the following specification. Input Voltage Range 150 to 280 VAC P-N / 350 - 460 VAC P-P (±15%) Input Frequency 50 Hz (±5%) Charging Current 1-5 A max (±1%) Output Frequency 50 Hz (±0.5%) Output Voltage 250 VAC P-N / 415 VAC P-P (±3%) Change Over Time 20 Seconds Load power Factor 0.8 to 1 lagging Inverter Efficiency 90% Output Wave form Pure sinewave Harmonic Distortion Less than 3% with linear load Overload 105% continuous 105% to 200% for 30 Sec. 200% Inverter Trips Indications Mains ON, Charging ON, Inverter ON, Battery Low, Overload Audible Alarm Battery Low pre-alarm at 80% of discharge / in ARD NO LOAD mode Protections Input single phasing / Battery under voltage / Output overload / Input MCB Changeover Electro-mechanical / Contactor based / Static Switch Backup time 30 seconds to 3 minutes (Auto Sense) Operating Temperature 0 °C to 55 °C Humidity Max 95%, Non-condensing Cooling Natural air cooling Acoustic Noise Less than 45 dB at 1 Meter etc., complete in all respects as directed by the departmental officers..

136

-

-

... More
Supply, Installation and Testing of CTB Board as per the following specification. 32-bit processor, serial communication, simple wiring, reliable and stable 8 way digital inputs, 10 way relay outputs Support car digital / analog weighing signal input Support LCD operation panel for easy modification and viewing of system parameters Car top board input and output are programmable etc., complete as directed by the departmental officers.

47

-

-

... More
Supply, Installation and Testing of Over speed governer unit as per the following specification. Pulley Dia. - 300mm Rope Dia. - 8mm Nominal Speed - 1 m/s Tripping Speed - 1.25 m/s etc complete as directed by the departmental officers.

137

-

-

... More
Supply, Installation and Testing of Phase preventer relay board as per the following specification. Supply Voltage 3x380-440Vac Output Relay / Channels SPCO Output Relay Rating 5A @ 230V Function Phase Failure Mounting DIN Rail Size 17.5mm Terminal Type Screw Terminals Connections 3 Wire Protection IP20, IP30 Special Features Adjustable On Delay Timer Weight 0.12 etc., complete in all respects as directed by the departmental officers.

122

-

-

... More
Supply, Installation and Testing of Door belt as per the following specification. Elevator Door Belt S8M Width:14mm, Teeth Space:5mm, 5meters HTD5M etc., complete in all respects directed by the departmental officers.

68

-

-

... More
Supply, Installation and Testing of Programble logic control board as per the following specification. Logic board for SINGLE SPEED ELEVATOR. Supply voltage requirement 12VAC/DC, 24VD & 110VAC for safety. On board number of stops 8. Maximum 16 stops with extension card. (G+15 down collective / G+10 full collective). Door operation MANUAL door. Speed support up to 0.7 m/s. Reed signals FLOOR REED & CABIN TOP REED as per requirement. Voltage rectifier (AC TO DC) power supply board embedded with the logic board so no need of external Voltage rectifier (AC TO DC). Status of all inputs & outputs though LED indication on board. User friendly & Compact design Functions Auto attendant. Auto fan. Fire mode. Stop. etc., complete as directed by the departmental officers.

42

-

-

... More
Supply, Installation and Testing of Cop push buttons as per the following specification. Shape: Oval Operating Voltage: 24 VDC Colour: Red etc complete as directed by the departmental officers.

576

-

-

... More
Supply, Installation and Testing of Landing door mechanisam with door panels as per the following specification. Clear Opening (mm) 800 Clear Height (mm) 2000 mm C2/Sill Package (mm) 40mm EN 81-20/50 Complied Aluminium Sill Yes Door Closing Spring etc., complete as directed by the departmental officers.

264

-

-

... More
Supply, Installation and Testing of Door motor work as per the following specification. Motor characteristics: Permanent magnet synchronous motor Drive system: Vector Control Max. power consumption: 80 W Max Speed: 0.5 m/s Max Panel Total Weight:130 kgs protection glass:IP20 Power Supply:127/230 VAC +/-20%, 50/60 Hz etc., complete in all respects directed by the departmental officers.

25

-

-

... More
Supply, Installation and Testing of Car door mechanisam with door panels as per the following specification. Design Of Door Auto Door CO Opening Style Center opening Height 2000 mm Material MS and SS Pattern landing door Color ivory Usage/Application elevator Operation Automatic Warranty Provided Brand : witter MS : yes etc., complete as directed by the departmental officers.

32

-

-

... More
Supply, Installation and Testing of Cabin platform fabrication work as per the following specification. Removing the existing mild steel passenger lift landing platform and replaceing it with mild steel sheat and alumimiyam chekar plate. etc., complete in all respects directed by the departmental officers.

17

-

-

... More
Supply, Installation and Testing of Sensor unit work as per the following specification. Voltage: AC220V, AC110V, DC24V Catagory: Elevator Spare Parts,Light Curtain Length: 2000MM Feature: WECO-957R71-AC220-F-2100mm Hangzhou XO Name: Infrared Door Sensor etc., complete in all respects directed by the departmental officers.

15

-

-

... More
Added GST @ 18%

1

-

-

... More
Supply, Installation and Testing of SMPS board as per the following specification. High Efficiency & low energy consumption Power LED indication Short circuit protection with auto restart Compact size Surge voltage protection up to 6 KV Input and Output fully Protection Minimum Noise ripple Less than 0.5% Line regulation Less than 5% Load regulation Sustainable in worse input power condition Soft start System With ON-OFF Switch Application for ELEVATORS & ESCALATOR Voltage Range O/P CH1 - 24VDC Current cap 5 Amp. Wattage 120W etc., complete in all respects directed by the departmental officers.

49

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.