Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.
Tamil Nadu Urban Habitat Development Board - TNUHDB Tender
Civil And Construction
Civil Works Others
Machinery and Tools
Eprocure
Opening Date20 Nov 2024
Closing Date4 Dec 2024
Tender AmountRefer Documents
Costs
EMD
₹ 3,90,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Tnuhdb /420/ Hd / Se East-ii / 2024
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_TNUHB_502923_1Bid Award Id
ViewTender No
TNUHDB /420/ HD / SE East-II / 2024Tender Authority
Tamil Nadu Urban Habitat Development Board ViewPurchaser Address
-Website
http://tntenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Supply, Installation and Testing of Breake coil unit 110v DC work as per the following specification. Coil: 110 VDC
Peak Current: 247 Amps
Holding Voltage: 110 VDC etc., complete in all respects directed by the departmental officers.
29
-
-
... More
sSupply, Installation and Mother board work as per the following specification. Elevator Load Capacity 680kg
Persons 6-10 input voltage:24v Speed 1.00m/s
Control Type Relay Control
Lift Mechanism center opening
Use of Occasions Indoor Type etc., complete in all respects directed by the departmental officers.
10
-
-
... More
Supply, Installation and Testing of ARD Board as per the following specification.
Input Voltage Range 150 to 280 VAC P-N / 350 - 460 VAC P-P (±15%)
Input Frequency 50 Hz (±5%)
Charging Current 1-5 A max (±1%)
Output Frequency 50 Hz (±0.5%)
Output Voltage 250 VAC P-N / 415 VAC P-P (±3%)
Change Over Time 20 Seconds
Load power Factor 0.8 to 1 lagging
Inverter Efficiency 90%
Output Wave form Pure sinewave
Harmonic Distortion Less than 3% with linear load
Overload 105% continuous 105% to 200% for 30 Sec. 200% Inverter Trips
Indications Mains ON, Charging ON, Inverter ON, Battery Low, Overload
Audible Alarm Battery Low pre-alarm at 80% of discharge / in ARD NO LOAD mode
Protections Input single phasing / Battery under voltage / Output overload / Input MCB
Changeover Electro-mechanical / Contactor based / Static Switch
Backup time 30 seconds to 3 minutes (Auto Sense)
Operating Temperature 0 °C to 55 °C
Humidity Max 95%, Non-condensing
Cooling Natural air cooling
Acoustic Noise Less than 45 dB at 1 Meter etc., complete in all respects as directed by the departmental officers..
136
-
-
... More
Supply, Installation and Testing of CTB Board as per the following specification. 32-bit processor, serial communication, simple wiring, reliable and stable 8 way digital inputs, 10 way relay outputs Support car digital / analog weighing signal input Support LCD operation panel for easy modification and viewing of system parameters Car top board input and output are programmable etc., complete as directed by the departmental officers.
47
-
-
... More
Supply, Installation and Testing of Over speed governer unit as per the following specification. Pulley Dia. - 300mm
Rope Dia. - 8mm
Nominal Speed - 1 m/s
Tripping Speed - 1.25 m/s
etc complete as directed by the departmental officers.
137
-
-
... More
Supply, Installation and Testing of Phase preventer relay board as per the following specification.
Supply Voltage 3x380-440Vac
Output Relay / Channels SPCO
Output Relay Rating 5A @ 230V
Function Phase Failure
Mounting DIN Rail
Size 17.5mm
Terminal Type Screw Terminals
Connections 3 Wire
Protection IP20, IP30
Special Features Adjustable On Delay Timer
Weight 0.12 etc., complete in all respects as directed by the departmental officers.
122
-
-
... More
Supply, Installation and Testing of Door belt as per the following specification.
Elevator Door Belt S8M Width:14mm, Teeth Space:5mm, 5meters HTD5M etc., complete in all respects directed by the departmental officers.
68
-
-
... More
Supply, Installation and Testing of Programble logic control board as per the following specification. Logic board for SINGLE SPEED ELEVATOR. Supply voltage requirement 12VAC/DC, 24VD & 110VAC for safety.
On board number of stops 8.
Maximum 16 stops with extension card. (G+15 down collective / G+10 full collective).
Door operation MANUAL door.
Speed support up to 0.7 m/s.
Reed signals FLOOR REED & CABIN TOP REED as per requirement.
Voltage rectifier (AC TO DC) power supply board embedded with the logic board so no need of external Voltage rectifier (AC TO DC).
Status of all inputs & outputs though LED
indication on board.
User friendly & Compact design Functions
Auto attendant.
Auto fan.
Fire mode.
Stop. etc., complete as directed by the departmental officers.
42
-
-
... More
Supply, Installation and Testing of Cop push buttons as per the following specification.
Shape: Oval
Operating Voltage: 24 VDC
Colour: Red etc complete as directed by the departmental officers.
576
-
-
... More
Supply, Installation and Testing of Landing door mechanisam with door panels as per the following specification. Clear Opening (mm) 800
Clear Height (mm) 2000 mm
C2/Sill Package (mm) 40mm
EN 81-20/50 Complied
Aluminium Sill Yes
Door Closing Spring
etc., complete as directed by the departmental officers.
264
-
-
... More
Supply, Installation and Testing of Door motor work as per the following specification. Motor characteristics: Permanent magnet synchronous motor
Drive system: Vector Control
Max. power consumption: 80 W
Max Speed: 0.5 m/s
Max Panel Total Weight:130 kgs
protection glass:IP20
Power Supply:127/230 VAC +/-20%, 50/60 Hz etc., complete in all respects directed by the departmental officers.
25
-
-
... More
Supply, Installation and Testing of Car door mechanisam with door panels as per the following specification.
Design Of Door Auto Door CO
Opening Style Center opening
Height 2000 mm
Material MS and SS
Pattern landing door
Color ivory
Usage/Application elevator
Operation Automatic
Warranty Provided
Brand : witter
MS : yes
etc., complete as directed by the departmental officers.
32
-
-
... More
Supply, Installation and Testing of Cabin platform fabrication work as per the following specification.
Removing the existing mild steel passenger lift landing platform and replaceing it with mild steel sheat and alumimiyam chekar plate. etc., complete in all respects directed by the departmental officers.
17
-
-
... More
Supply, Installation and Testing of Sensor unit work as per the following specification.
Voltage: AC220V, AC110V, DC24V Catagory: Elevator Spare Parts,Light Curtain
Length: 2000MM Feature: WECO-957R71-AC220-F-2100mm Hangzhou XO
Name: Infrared Door Sensor etc., complete in all respects directed by the departmental officers.
15
-
-
... More
Added GST @ 18%
1
-
-
... More
Supply, Installation and Testing of SMPS board as per the following specification.
High Efficiency & low energy consumption
Power LED indication
Short circuit protection with auto restart
Compact size
Surge voltage protection up to 6 KV
Input and Output fully Protection
Minimum Noise ripple
Less than 0.5% Line regulation
Less than 5% Load regulation
Sustainable in worse input power condition
Soft start System
With ON-OFF Switch
Application for ELEVATORS & ESCALATOR
Voltage Range O/P CH1 - 24VDC
Current cap 5 Amp.
Wattage 120W etc., complete in all respects directed by the departmental officers.