Tamil Nadu Housing Board Tender

Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.

Tamil Nadu Housing Board Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date19 Jul 2024
Closing Date2 Aug 2024
Tender Amount₹ 1,37,76,954 
Notes
Download

Costs

Summary

Construction Of Gym Hospital In 240 Mla Quarters

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Construction of Gym and Hospital Building in 240 MLA Quarters at Government Estate Chennai
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Dismantling the damaged brick / stone masonry work in cement mortar and clearing away with carefully stacking the material useful for reuse for any thickness of wall under 3 m heights etc., complete complying with standard specification and as directed by the Departmental Officer.

10

-

-

... More
Earthwork excavation in all stiff clay, stiff back cotton, hard red earth, shales, murram, gravel, stoney earth and earth mixed with small size boulders and to the required depth as may be directed except in hard rock requiring blasting inclusive of shoring strutting and baling out water wherever necessary, depositing the surplus earth in places shown clearing and leveling the site with an initial lead of 10 metre and lifts as specified hereunder etc., all complete in all respects complying with relevant standard specification (excluding refilling)

293

-

-

... More
Laying the plain cement concrete 1:2:4(one cement two M sand and four broken machine crushed stone jelly) using HBG Machine crushed stone jelly of size 20 mm gauge for foundation and basement including de-watering if found necessary and laid in layers of not more than 15 cms thick etc all complete complying with relevant standard specification and as directed by the departmental officers

6

-

-

... More
Refilling in foundation and basement and other similar works with excavated earth in layers of 150mm thickness well watered rammed and consolidated etc all complete complying with relevant standard specifications and as directed by the Departmental officers.

5

-

-

... More
Providing pre-constructional Antitermite treatment including cost of chemicals labour as per standard specifications for preparing the area for treatment by spraying chemicals and other incidental charges etc.. complete. The rates should be for antitermite treatment from the plinth beam and brick masonry with super structure in contact with the back fill earth and at the junction of the walls. The top surface of filled earth for flooring and the soil along with the perimeter of the building by making holes with the crow bar and poured 5% termicide “Chloripyrifos” and spraying the same termicide solution on the wooden frames and treating the other periphery of buildings etc., complete in all respects as per IS 6313 (part II) / 1981 and as directed by the departmental officers.

299

-

-

... More
filling in foundation and basement and other similar works with Filling M Sand in layers of 150mm thickness well watered rammed and consolidated complying with relevant standard specifications as directed by the Departmental officers.

49

-

-

... More
laying the Plain Cement concrete 1:5:10 (One cement five M sand and ten broken Machine crushed stone jelly) using HBG Machine creased Machine crushed stone jelly of size 40mm gauge for founding and basement including de- watering if found necessary and laid in layers of not more than 15cms thick etc., complete complying with standard specification and as directed by the departmental officers.

55

-

-

... More
laying the Reinforced cement concrete 1:1.5:3 (One cement one point five M sand and three broken Machine crushed stone jelly) using 20mm gauge hard broken granite jelly for all RCC works such as slabs, beams, footings, staircase waist slabs, steps, landing beams fins, boxing, vertical louver, drops, window sill slabs projection and other similar works including laying curing etc., complete complying with standard specification and as directed by the departmental officers.

-

-

-

... More
a) Foundation & Basement

68

-

-

... More
b) Ground Floor SUPER STRUCTURE

61

-

-

... More
c)For First Floor up to 4.50 M height

4

-

-

... More
Supplying and erecting centering for sides and soffits including necessary supports and strutting up to 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at about 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specification. (Payment for centering shall be given after the concrete is laid)

-

-

-

... More
a) For column footing plinth beam bed blocks templates staircase, steps piers raft beam raft slab etc.,

252

-

-

... More
b) For plane surfaces such as rectangular or square RCC columns, sunshades, top and bottom slab of RCC boxing, etc

208

-

-

... More
c) For plane surfaces such as RCC floor slab, roof slab, beams, lintels, bed blocks, landing slab, waist slab, portico slabs and beams, etc.

542

-

-

... More
Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel grills for all RCC works as per design given including cost of steel and G.I. binding wire in all floors etc. complete complying with standard specification. (Contractor has to make his own arrangements for the supply of steel and binding wire)

17.29

-

-

... More
AAC (Autoclaved aerated concrete) Block Work using Self curing AAC mortar joint 2-3mm thick inbetween the blocks with a spread of 170sqft/40 kg ,cement mortor 1:6 ( One of cement and Six of M Sand) along the boundaries using AAC block of size 600x200x225mm having minimum average crushing strength of 50Kg/sqcm including dewatering wherever necessary proper setting curing etc., complete in all respects complying with relevant standard specifications and as directed by the departmental officers

-

-

-

... More
a) For Foundation Basement

30

-

-

... More
b) For Ground Floor

54

-

-

... More
c) For First Floor up to 4.50 M height

18

-

-

... More
Autoclaved cellular Aerated Concrete Block partition wall in CM 1:4 (One of cement and four of M sand) 10.00 CM thickness using of size 60 x 20 CM and using hoop iron with reinforcement if found necessary. With etc., complete complying with standard specification and as directed by the Departmental officers.

151

-

-

... More
Plastering with cement mortar 1:3 (one cement and three P sand) 12mm thick with fine P sand for plastering including curing, neat finishing, etc., complete complying with standard specification and as directed by the Departmental officers.

333

-

-

... More
Plastering the new walls with Cement Mortar 1:5 12 mm thick using the P sand including curing and finishing neatly complying with standard specification and as directed by the departmental officers etc. complete.

1012

-

-

... More
Stucco plastering 12mm thick using the10mm metal chips and the river sand including curing and finishing neatly complying with standard specification and as directed by the departmental officers etc. complete.

491

-

-

... More
Providing Teak wood wrought and put up for frames of doors, windows and ventilators and any other similar joinery works including cost of country wood scantlings and labour charges for manufacturing the frames and fixing hold fasts and fixing in position etc. for all lengths as per architect designs.

-

-

-

... More
a) Teak wood scantling up to 2 M length

0.13

-

-

... More
b) Teak wood scantling 2 M to 3 M length

0.31

-

-

... More
Supplying and fixing of best approved quality MS hold fast horizontally twisted of size 230 x 40 x 4mm with a pair of suitable Iron screws..etc all complete Complying with relevant standard specifications and as directed by the Departmental officers.

54

-

-

... More
Supplying and fixing of Best Indian Teak Wood Shutter Panelled door Shutters single leaf in Position using 75x37.5mm rails and 4 Nos of 150x37.5mm rails (top, middle, bottom & Lock rails) 2 Nos of 75x37.5mm vertical shorter styles and 18.75mm thick planks for panels including cost of aluminium furniture fittings such as 1 No 150mm handle with CP screws 3 Nos 125mm butt hingers with cp screws 2 Nos 150x12mm tower bolt, 250x15mm aldrop and 1 No nylon bush etc. all complete Complying with relevant standard specifications and as directed by the Departmental officers.

-

-

-

... More
a) Teak Wood Shutter DOUBLE LEAF FULLY PANELLED DOOR SHUTTER FOR DOOR OF SIZE 1500 X 2100MM

6

-

-

... More
b) Teak Wood Shutter Single LEAF FULLY PANELLED DOOR SHUTTER FOR DOOR OF SIZE 1000 X 2100MM

14

-

-

... More
Supplying and fixing of solid core PVC door shutters with PVC frame of size 50X40mm with suitable rebate for housing shutter (conforming to I S 4020 with updated amendment)consisting of frame made of 19 gauge 19mm MS sq.tubes for styles and outer frames. 15mm MS sq. tubes for top,lock and bottom rails.The steel tubes shall be covered with 5mm thick solid PVC sheets.Shutter using 5mm thick solid PVC sheets for panelling shall rigidly fixed in position including necessary furiture and fitting.The overall styles shall be 50x30mm.The overallsize of top rail,lock rail and bottom rail shall be 75mmx30mm.The overall size of frames shall be 50x45mm,with suitabe rebate for housing the shutters. The shutter shall be provided with 3 Nos of 4” aluminium / SS butt hinges, 2 Nos of 4” Aluminium / Stainless Steel handles, 3 Nos of 6” Aluminium / Stainless Steel tower bolts with required Stainless Steel / Aluminium screws including labour charges for fixing the shutter frame, shutter and furniture fittings in position and finished smooth with template etc., all complete as directed by the departmental officers. (Fittings provided shall bear ISI mark . The quality and brand of door shutter and furniture fittings should be got approved by the Executive Engineer before use)

12

-

-

... More
Supply and fixing of UPVC glazed window with frame made out of hollow multi-chambered UPVC sections having isolated drainage and reinforced with galvanized steel. The corners and joints shall be mitre cut and fusion welded. The outer frame of the window shall be made out of UPVC sections having an overall size of 60mmx60mmx40mm having wall thickness of 2.3mm, + or - 0.3mm and provided with steel reinforcement at a hardware location and size of 27mmx21.5mm. The fixed mullion shall be made out of UPVC sections having an overall size of 76mmx60mmx36mm having wall thickness of 2.3mm, + or - 0.3mm. (The brand and quality of PVC shutters should be got approved from the EE before use) etc., all complete Complying with relevant standard specifications and as directed by the Departmental officers.

28

-

-

... More
Supplying and fixing of Premium Vertical blinds of approved quality and colour inclusive of all accessories as per site condition and cost of all materials and labour charges and as directed by the departmental officers. (The Quality and shade of vertical blinds should be got approved from the EE before use on work)

36

-

-

... More
Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work

3

-

-

... More
Providing UPVC (Un-Plasticized Polyvinyl Chloride) Door: Providing and fixing casement doors fabricated from un-plasticized polyvinyl chloride (UPVC) sections. Profiles: The profiles should be three chamber system which provides high insulation properties with outer frame 60mm x 55mm with an outer wall thickness of 2.4mm. The window unit should be designed with all corner joints mitred and fusion welded. Windows should be steel reinforced with 25 x 24 x 25mm steel reinforcement with a thickness of 1mm to have dimensional stability. The sash should be of 60 x 102mm. The mullion should be of 60 x 74mm. The profiles should have co extruded seals. Hardware: All the hardware like friction stays, handles should be screwed with self tapping screws. The handles, locks should be designed so that they cannot be released from outside. Glazing: The window system should be glazed with 5mm plain float glass / 6mm bison lam Installation: The profiles should be cut to length and welded 45 degrees. The window should be designed such that the water drainage does not pass through the reinforcement chamber. The window system should be fixed directly to the plastered brick wall using self expanding nylon plug and driving ms electroplated screws into plug.

10

-

-

... More
Supplying and fixing Mild Steel grills for windows, Ventilators verandah enclosure and gate as per the design approved including one coat of primer and labour for fixing in position etc. all complete complying with relevant standard specification and as directed by the Departmental officers. (The design of grill should be got approved from the EE before use)

1154

-

-

... More
Supplying and fixing of Double Charged vitrified tiles of size 600 mm x600 mm x 8mm of best approved quality and colour laid in cement mortar 1:3 ( One of Cement and three of M sand) 20mm thick and pointed with coloured cement neatly including cutting to the required size and shape wherever necessary finishing neatly etc. all complete complying with relevant standard specification and as directed by the Departmental officers. (The Colour and quality of the tiles should be got approved by the EE before use)

234

-

-

... More
Supplying and laying of ceramic tiles anti skid of any size of approved special quality laid in cement mortar 1:3 (One of cement and three of sand) 20mm thick for flooring including cost of tiles fixing in position cutting the tiles to the required size wherever necessary pointing the joints with white/ colour cements neatly curing, finishing including cost of cement mortar etc all complete in all respects complying with relevant specification and as directed by the departmental officers. Note:(The size, colour and quality shall be approved from the E.E before use)

17

-

-

... More
Supplying and fixing in position of colour glazed wall tiles of any size 6mm thickness laid in cement mortar 1:2 ( One of cement and two of sand) 10mm thick for wall facing / dadoing ,skirting over the plastered surfaces including cost of tiles fixing in position cutting the tiles to the required size wherever necessary pointing the joints with white/ colour cements neatly curing, finishing including cost of cement mortar etc complete and as directed by the departmental officers. Note:(The size, colour make and quality shall be approved from the EE before use)

85

-

-

... More
Finishing the top of terrace floor with one course of solar reflective water proof, heat proof, cool proof tiles of size 300mm x 300mm x 8mm of approved quality laid in cement mortar 1:3 (One part of cement and three part of sand) mixed with chemical mineral powder (60 kg for 1000 Sqft) (before laying tiles, the tiles should be dipped with salin based nano liquid) and top pointing with cement mortar 1:3 (One part of cement and three part of sand) mixed with white cement, silicon powder and polymer additives (20Kg of 1000 Sqft) and joint pointed with a base concrete of PCC 1:2:4 using 6 to 10 mm metal for providing necessary gradient at top of roof etc., complete complying with standard specifications including cost of all materials, labour charges for lifting to open terrace, laying and finishing and other incidental charges etc., complete and as directed by the departmental officers. (The Brand and quality of tiles should be got approved from the Executive Engineer before using)

273

-

-

... More
Finishing the top of flooring with cement concrete 1:3 Ellis pattern flooring 20mm thick in cement concrete 1:3( One of cement and Three of stone jelly ) using 10mm and less hard broken stone chips (No M Sand to be used) including laying ,curing, finishing..etc complete complying with relevant standard specifications and as directed by departmental officers.

262

-

-

... More
Laying with new CC laminated tiles (like Dora tiles, eurocon tiles etc., anti skid) of 20mm thick approved special quality and set in CM 1:3 (One cement and three M sand) 20mm thick using M sand and pointing with colour cement at the rate of 0.40kg/m2 etc complete complying with relevant standard specifications and as directed by departmental officers.

34

-

-

... More
Providing water proof cement plaster 1:4 (one of cement and four of sand), 12mm thick with neat cement including water proofing compound at the rate of 2% by weight of cement used to the side wall up to the sunken portion including laying, curing, finishing..etc all complete in all respects complying with relevant standard specifications and as directed by the departmental officers.

30

-

-

... More
Providing and laying broken brick jelly lime concrete using 20mm gauge broken brick jelly in pure slaked lime (no sand) in sunken portion to the proportion of brick jelly to lime (Fat lime) being 32: 12 1/2 by volume mixed with water proofing concrete at the rate of 2.8kg/m3, well beaten with wooden beaters, for giving the required slope and thickness including laying and finishing ..etc complete complying with relevant standard specification and as directed by the departmental officers.

4.9

-

-

... More
Distempering the ceiling one coat with best oil bound distemper of approved quality including preparation of surfaces (the colour and quality should be got approved by the Executive Engineer before use) the rate includes cost of brushes, high scaffolding charges, neat finishing, cost of brushes etc., complete complying with standard specification and as directed by the Departmental Officer

333

-

-

... More
Painting the walls with Two coats with first class quality Plastic Emulsion paint of approved colour over a priming coat including thorough scraping, clean removal of dirt. The rate includes cost of brushes, sand paper, plaster of parries, putty wherever required and neat finishing etc., complete complying with standard specification and as directed by the Departmental Officer (the colour and quality should be got approved by the Executive Engineer before use)

1012

-

-

... More
Providing and applying best approved quality wall putty of 2mm thick two coat over the plastering surfaces to have even and smooth surface to receive the painting including cost of all materials, brushes, labour charges , scaffolding etc., all complete in all respects complying with relevant standard specification and as directed by the departmental officers (quality of Putty shall be got approved from the Executive Engineer before using) TNBP 65Ai

1012

-

-

... More
Painting the outer walls two coats with approved Weather shield paint in addition to one coat of approved Primer over cement plastered wall surfaces etc. including cost of Cement paint,putty, brushes, scaffolding etc., all complete in all respects complying with relevant standard specification and as directed by the departmental officers (paints and its shade shall be got approved from the EE before use) TNBP 65A

491

-

-

... More
Varnishing the new wood work two coats using best approved wine varnish by gun spray including preparation of surface and neat finish etc., all complete complying with relevant standard specifications and as directed by the departmental officers. (The quality of varnish should be got approved by EE before use)

17

-

-

... More
Painting new wood work two coats with approved Ist class synthetic enamel ready mixed paint in addition to one coat of primer of approved quality and shade. The paint should be supplied by the contractor at his own cost, including cost of brushes, labour etc., all complete complying with relevant standard specifications and as directed by the departmental officers. (The quality of varnish should be got approved by EE before use)

39

-

-

... More
Painting the new Iron work for staircase handrail, Window grills, rolling shutters and other similar works with two coats of approved first class synthetic enamel ready mixed paint of approved quality and brand, the paint should be supplied by the contractor at his own cost, (The quality and the brand of paint should be got approved by the Executive Engineer before use) complying with relevant standard specifications and as directed by the departmental officers

63

-

-

... More
Supplying and fixing of 110mm dia PVC SWR pipe A Type for Rain water down fall pipe conforming to IS13592 with ISI mark and fittings conforming to IS 14735, with necessary C I gratings, shoes, bends, offsets, clamps, teak wood plugs, etc., of approved quality including fixing C.I. gratings at the junction of parapet and floor or roof slab, finishing etc., complete complying with relevant standard specifications and as directed by the departmental officers

48

-

-

... More
Supplying laying, fixing and jointing the following ASTM-D-1785 schedule-80 of wall thickness not less than the specified in IS 4985 UPVC pipes and specials suitable for plumbing by threading including cost of materials PVC/GI specilas GM specials like Elbow, Tee, reducers, Plug, Union, Bend, Coupler Nipple, GM gate valve Checkvalve, and wheel valve etc wherever required etc all complete including necessary earth work and refilling after pipes are laid below GL true to alignment and slope, testing with water etc., all complete compplying with relevant standard specification and as directed by the departmental officers. (The brand and quality of the pipes should be got approved from EE before use)

-

-

-

... More
a) 32 mm UPVC Pipe

120

-

-

... More
b) 25 mm UPVC Pipe

49.5

-

-

... More
c) 20 mm CPVC Pipe

70

-

-

... More
Supply and erection of Rotational moulded polyethylene water storage tanks (HDPE Cylindrical vertical type) for out door use having capacity of 750 litres (Excluding free board) of approved brand (Superior variety) with ISI mark (marked in the tank itself) with top lid with provisions of locking including necessary specials and fittings for storing potable water and manufactured with material which do not import any taste/odour/any toxic effect and not to contaminate etc with carbon block content and dispersion in accordance with relevant I.S. specification and as directed by the departmental officers etc complete in all respects ( The quality of HDPE tank should be got approved from the EE before use.)

4

-

-

... More
Supplying and fixing of porcelain Wash Hand basin (White) with pedestal of superior variety of size 550 mm x400 mm (22 "x16”) including cost and fixing of CI brackets, pvc waste pipe required grating, cp tap, wheel valve/ Bib cock, pvc, connection, c.p waste plug with aluminium chain etc., all complete complying with relevant standard specification and as directed by the departmental officers.

4

-

-

... More
Supplying and fixing in position White Glazed Model European Water Closet of best quality and approved make with 100mm “S” trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws,Cistern set including Dual flushing tank with a pair of CI brackets, etc., complete with all fittings, such as, 15mm brass ball valve with polythene float with brass handle, union coupling connected by means of 40mm white PVC flush hand using indian adopter joint including all internal fittings, such as, 15mm bras connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition, etc., complete complying with standard specifications. (The EWC and flushing tank with all accessories should be got approved by the Executive Engineer before use on works)

7

-

-

... More
Supplying and fixing of PVC Nahani Trap not less than 75mm 4 way / 2 way (Superior variety) having minimum of water seal of 50mm confirm to relevant I.S. specifications with its latest amendments including resting on the bed of brick jelly concrete 1:5:10 (One of cement, five of sand of ten of 40 mm gauge brick jelly) etc., complete complying with relevant standard specifications and as directed by the departmental officers.(The PVC Nahani Trap should be got approved from the EE before use)

18

-

-

... More
Supplying and fixing the following dia PVC (SWR) pipe type B class conforming to IS 13592and relevant specials including packing the joints with rubber lubricant fixing them into walls with necessary GI clamp and GI Bolts, holding wherever necessary and making good of the dismantled portion with necessary connections etc., complete complying with relevant standard specifications and as directed by the departmental officers. (The brand and quality of the pipe should be got approved by EE before use)

-

-

-

... More
a) 110 mm dia PVC SWR Pipe

90

-

-

... More
b) 75 mm dia PVC SWR pipe

90

-

-

... More
Supplying and fixing of SS Heavy Duty Long Body Tap 15mm with wall flange with Essco fittings (Model No.511) including cost of fittings , labour for fixing etc, complete complying with relevant standard specifications and as directed by the departmental officers. (The quality of fittings should be got approved from Executive Engineer before use)

7

-

-

... More
Supplying and fixing of C.P Short body Bip cock with wall flange with Essco fittings (Model No.511) including cost of fittings , labour for fixing etc, complete complying with relevant standard specifications and as directed by the departmental officers. (The quality of fittings should be got approved from Executive Engineer before use)

7

-

-

... More
Supplying and fixing of C.P Concealed stop Cock with sliding flange (Model No. 514 E) of Essco Fittings including cost of fittings , labour for fixing etc, complete complying with relevant standard specifications and as directed by the departmental officers. (The quality of fittings should be got approved from Executive Engineer before use).

11

-

-

... More
Supplying and fixing of CP Two Way Bib Cock with Health Faucet including cost of fittings , labour for fixing etc, complete complying with relevant standard specifications and as directed by the departmental officers. (The quality of fittings should be got approved from Executive Engineer before use).

7

-

-

... More
Construction of Inspection chamber 0f following size with brick jelly concrete 1:8:16 (one of cement eight of sand and sixteen of broken brick jelly using 40mm gauge broken brick jelly 15cm thick for foundation and 23cm thick brick masonry in C.M. 1:5 (One of cement and five of sand) using stock bricks of size 9" x 4 3/8" x 2 3/4" plastering with cement mortar 1:3 (One of cement and three of sand) 12mm thick on both sides top and bottom including earth work excavation Man Hole Cover SFRC Size 600 X 600 mm and Fixing in Position etc., Complete. with nominal reinforcement, moulding, fixing in position etc., complete complying with relevant standard specifications and as directed by the departmental officers.

-

-

-

... More
a) 60x60x60cms

10

-

-

... More
b) 60x60x75cms

2

-

-

... More
c) 60x60x90cms

2

-

-

... More
Providing two legged scaffolding using 15 cm dia casuarinas post of 4 M over all length (3 M Height =0.5 m projection+0.5m into the ground 0the distance between the two rows being 1.25m and the spacing of posts being 2.0 M in both the row with two horizontal posts with 0.5m overlap on either side and braces at 2.0 m center to center including longitudinal and transverse middle braces to step up and providing a platform with country wood planks of 40mm thick and 1m width etc in a complete from using coil and nails.

-

-

-

... More
a)for initial height of 3 m

28

-

-

... More
b) for every Additional height 2.5 m 3 to 5.50 m

28

-

-

... More
Supply and erection of ambulanceshelter truss of size 9.60 x 5.6 x 4.00 m .It is made of 75mm x40mmx4 0mm channel , 6 mm thickness 2 nos welded as a vertical post and diagonal post . The distance between the vertical post is 2.75 m c/c. The truss made up of by using 25 mm MS Tube (10 Gauge) as a truss the design as per the drawing enclosed. The poles in between span that is purl in made up of by using 40 mm MS Tube (10Gauge) . for making post truss purlins, including Labour charges welding and fixing to proper position etc all complete complying with relevant standard specification and as directed by the departmental officers.

1

-

-

... More
Supply and fixing of Galvanized sheet of 0.47 mm thick with required bolts and nuts labour charges fixing the sheet in proper position etc all complete complying with relevant standard specification and as directed by the departmental officers

42

-

-

... More
Wiring with 2 wire 1.5 sqmm copper PVC insulated unsheathed single core Multi Strand Fire Retardant 1.1 KV grade copper cable with ISI Mark conforming to IS:694/1990and with continuous earth by means of 1.5 sqmm copper insulated unsheathed single core Multi Strand Fire Retardant 1.1 KV grade copper cable with ISI Mark conforming to IS:694/1990 in fully concealed PVC rigid conduit pipe heavy duty with ISI with suitable size MS box of 16 gauge thick concealed and covered with 3mm thick laminated hylem sheet for light point with ceiling rose controlled by 5 amps flush type switch including circuit mains cost of all materials, specials etc., all complete complying with relevant standard specifications and as directed by the departmental officers...

30

-

-

... More
Wiring with 2 wire 1.5 sqmm copper PVC insulated unsheathed single core Multi Strand Fire Retardant 1.1 KV grade copper cable with ISI Mark conforming to IS:694/1990and with continuous earth by means of 1.5 sqmm copper insulated unsheathed single core Multi Strand Fire Retardant 1.1 KV grade copper cable with ISI Mark conforming to IS:694/1990 in fully concealed PVC rigid conduit pipe heavy duty with ISI with suitable size MS box of 16 gauge thick concealed and covered with 3mm thick laminated hylem sheet for light point with bakelite battern holder controlled by 5 amps flush type switch including circuit mains cost of all materials, specials etc., all complete complying with relevant standard specifications and as directed by the departmental officers...

20

-

-

... More
Wiring with 2 wire 1.5 sqmm copper P.V.C. insulated unsheathed single core Multi Strand Fire Retardant 1.1 KV grade copper cable with ISI Mark conforming to IS:694/1990 and with continuous earth by means of 1.5 sqmm copper PVC insulated unsheathed single core Multi Strand Fire Retardant 1.1 KV grade copper cable with ISI Mark conforming to IS:694/1990 in fully concealed PVC rigid conduit pipe heavy duty with ISI mark with suitable size MS box of 16 gauge thick concealed and covered with 3mm thick laminated hylem sheet for buzzer/calling bell poits including circuit mains, cost of all materials, specials, etc., all complete complying with relevant standard specifications & as directed by the departmental officers..

2

-

-

... More
Wiring with 1.5 sqmm copper P.V.C. insulated unsheathed single core Multi Strand Fire Retardant 1.1 KV grade copper cable with ISI Mark conforming to IS:694/1990and with continuous earth by means of 1.5 sqmm copper PVC insulated unsheathed single core Multi Strand Fire Retardant 1.1 KV grade copper cable with ISI Mark conforming to IS:694/1990 in fully concealed PVC rigid conduit pipe heavy duty with ISI mark with suitable size MS box of 16g thick concealed and covered with 3mm thick laminated hylem sheet for Fan point controlled by 5 amps flush type switch including circuit mains, cost of all materials, specials, etc., all complete complying with relevant standard specifications & as directed by the departmental officers

15

-

-

... More
Wiring with 2 wire 1.5 sqmm copper P.V.C. insulated unsheathed single core Multi Strand Fire Retardant 1.1 KV grade copper cable with ISI Mark conforming to IS:694/1990and1.1.k.v. grade cable with continuous earth by means of 1.5 sq.mm copper PVC insulated unsheathed single core Multi Strand Fire Retardant 1.1 KV grade copper cable with ISI Mark conforming to IS:694/1990and grade cable in fully concealed PVC rigid conduit pipe heavy duty with ISI mark with suitable size MS box of 1 No (each) 16g thick concealed and covered with 3mm thick laminated hylem sheet for 5 amps. 5 pin plug socket point at convenient places including circuit mains, cost of all materials, specials, etc., all complete complying with relevant standard specifications & as directed by the departmental officers..

60

-

-

... More
Wiring with 2 wire 1.5 sqmm copper P.V.C. insulated unsheathed single core Multi Strand Fire Retardant 1.1 KV grade copper cable with ISI Mark conforming to IS:694/1990 and with continuous earth by means of 1.5 sqmm copper PVC insulated unsheathed single core Multi Strand Fire Retardant 1.1 KV grade copper cable with ISI Mark conforming to IS:694/1990 in fully concealed PVC rigid conduit pipe heavy duty with ISI mark with suitable size MS box of 16 gauge thick concealed and covered with 3mm thick laminated hylem sheet for 5 amps 5 pin plug socket point at Switch Board Itself including circuit mains, cost of all materials, specials, etc., all complete complying with relevant standard specifications & as directed by the departmental officers..

30

-

-

... More
Supplying and fixing Of Fan Box with Hook inclusive of all connections and cost of all materials all complete, complying with relevant standard specifications & as directed by the departmental officers.

15

-

-

... More
Supply and delivery of 1200mm (48") Sweep Electric Ceiling fan conforming to IS 374/1979 with blades and double ball bearing, capacitor, etc. complete with 300 mm down rod suitable for operation on 230 volts 50 HZ. The Brand / Model of the fan has to be got approved by the EE before supply)

15

-

-

... More
Supplying and fixing 15amps 3 pin plug Flush type socket and 15 amps flush type switch switch on a suitable MS box 16g thick concealed and covered with 3 mm thick laminated hylem sheet inclusive of all connections and cost of all materials all complete, complying with relevant standard specifications & as directed by the departmental officers.

30

-

-

... More
Supplying and fixing 15amps 3 pin Flush plug type switch on a suitable MS box 16g thick concealed and covered with 3 mm thick laminated hylem sheet inclusive of all connections and cost of all materials all complete, complying with relevant standard specifications & as directed by the departmental officers.

7

-

-

... More
Supplying and fixing of 5W 1 Feet LED Fitting with LED etc.,complete with ISI mark, complying with relevant standard specifications & as directed by the departmental officers.including all accessories like PVC Round Sheet ,Wire etc ( The Brand/Quality of fittings has to be got approved by the EE before fixing) .

15

-

-

... More
Supply and fixing of 225mm sweep (light duty) AC exhaust fan complete with necessary wall opening and making good of the wall etc., all complete complying with relevant standard specifications & as directed by the departmental officers.( The Brand/Quality of exhaust fan has to be got approved by the EE before fixing) .

7

-

-

... More
Providing earthing station using pipe electrode as per IS 3043 using 40mm dia B Glass G.I pipe 1 metre 40x20mm G.I. Reducer 1 no. 1 set of funel G.I. nuts, bolts, washers and checknuts, 1 no.of C.I. cover (30x30cm) 40kg charcoal, 2nos. Of C.I. bend 15mm dia 4 Nos. of 15mm dia G.I. coupling and 10kg salt including necessary earth work excavation (i.e. by augering 30cm dia to a depth of 3.5 metres) and laying the salt and charcoal in layer by layer around G.I. pipe brick work in Cement mortor and plastering etc, including cost of all materials and labour etc, complete in accordance with IS3043.complying with relevent standard specifications and as directed by the departmental officers.

6

-

-

... More
Supplying and laying of 8 SWG GI wire on wall / below ground levels with necessary ‘U’ Nails, earth work excavation and refilling etc... Including cost of all materials etc.. all complete complying with relevant standard specifications & as directed by the departmental officers..

60

-

-

... More
supplying and fixing 7 segements (3 Tier) 3 phase distribution board with MCB 6 way TPMCB sheet steel distribution board flush/surface type fitted with bus bar and netural link with three phase MCB outgoings and sepeate 4 way provision for accomadiating one no of 4 pile incoming MCB and another sepearate 4 way provision for accommadating one No of four pole ELCB /RCD (totally 8 ways in one segment) (3 x 4 ways in each segment) and seperate provision for MCB 12 nos o for sub incomer in 3 segements with label holder and provision for taking up cable for size not less than 25 sqmm The cost inclusive of 63 Amps 3 phase 500 V 4 Pole change over switch, MCB - 1No.,20Amps SP 10 KA MCB - 18 No and fixing the labour charges at required places etc., complete complying with standard dpecification and as directed by the departmental officer

2

-

-

... More
Supplying and fixing of 18W 4 Feet LED Fitting with LED etc., complete with ISI mark, complying with relevant standard specifications & as directed by the departmental officers. (The Brand/Quality of fittings and Lamp has to be got approved by the EE before fixing).

20

-

-

... More
Supplying and fixing of 3 Nos. of 63 amps, 500 volts grade PORCELAIN FUSE UNIT EB.Pole including necessary interconnection and earth connection cost of all materials etc all complete complying with relevent standard specification and as directed by the Departmental officers.

2

-

-

... More
Supply & Fixing three phase ELCB / RCCB in TW Board including necessary interconnection and earth connection cost of all materials etc all complete complying with relevent standard specification and as directed by the Departmental officers.

2

-

-

... More
Run of main with 2 wires of 2.5 Sqmm Copper PVC insulated unsheathed single core Multi Strand Fire Retardant 1.1 KV grade copper cable with ISI Mark conforming to IS:694/1990 and with continuous earth by means of 1.5 sqmm copper PVC insulated unsheathed single core Multi Strand Fire Retardant 1.1 KV grade copper cable with ISI Mark conforming to IS:694/1990 in fully concealed 19/20mm dia rigid PVC conduit pipe with ISI mark etc. including cost of all materials, specials etc. all complete and as directed by the departmental officers.

300

-

-

... More
Run of main with 2 wires of 4 Sqmm Copper PVC insulated unsheathed single core Multi Strand Fire Retardant 1.1 KV grade copper cable with ISI Mark conforming to IS:694/1990 and with continuous earth by means of 2.5 sqmm copper PVC insulated unsheathed single core Multi Strand Fire Retardant 1.1 KV grade copper cable with ISI Mark conforming to IS:694/1990 in fully concealed 19/20mm dia rigid PVC conduit pipe with ISI mark etc. including cost of all materials, specials etc. all complete and as directed by the departmental officers.

280

-

-

... More
Run of main with 4 wires of 6 Sqmm Copper PVC insulated unsheathed single core Multi Strand Fire Retardant 1.1 KV grade copper cable with ISI Mark conforming to IS:694/1990 and with continuous earth by means of 4sqmm copper PVC insulated unsheathed single core Multi Strand Fire Retardant 1.1 KV grade copper cable with ISI Mark conforming to IS:694/1990 in fully concealed 25mm dia rigid PVC conduit pipe with ISI mark etc. including cost of all materials, specials etc. all complete and as directed by the departmental officers.

210

-

-

... More
Supplying laying and connecting 3 1/2 core 150 sqmm aluminium armoured UG cable with ISI mark of reputed brand including fixing below ground level with necessaryearthwork exavation,refilling the same with exavated earth,filling the trenches with bricks and sand as a cushion including cost of all materials redoing the dismantled portion, etc., all complete complying with relevant standard specification and as directed by the Departmental Officers. (The quality and brand of UG cable should be got approved from Executive Engineer before use).

100

-

-

... More
Supplying, fixing, connecting and commissioning of 20AMPS Metal clad socket for Air Conditioner (Superior variety) combined with 20AMPS SP MCB in Manufactures mount box fixed flush with the wall including cost of material, necessary interconnection etc, switch on suitable angle Iron frame work with necessary earthing etc., all complete and as directed by the departmental officers., (The quality and brand of fittings should be got approved from Executive Engineer before use).

14

-

-

... More
Supply, delivery and errection of 2 TR split AC units ( 5 star ), 5 KVA double booster stablizer out door unit MS stand with powder coating,5/8" & 3/8" Copper pipe 8m indoor waste PVC pipe 5 RMT, in between the door and out door unit copper pipe, controlling cable with pipe insulation 4 RMT and transportation inclusive of all taxes etc all complete complying with relevant standard specifications and as directed by the departmental officers.

14

-

-

... More
Supplying and fixing 8mm thick calcium silicate board designed (Sound absorbing material ) and perforated for false ceiling using best quality calcium silicate board perforated tiles with glass wool at at the bottom of roof beam and roof slab using ‘u’ shaped Galvanized iron channel of size 25 x 25 x 0.55mm thick at 1.20m center to center on both longitudinal and cross direction for vertical support and fixing ‘u’ shape GI channel of size 50 x 30 x .055mm thick at 0.60 m center to center on cross direction and fixing of ‘u’ shaped GI channel of size 50 x 10 x 0.055mm thick at 0.90m center to center on longitudinal direction respectively for horizontal support by using T.W reapers at corners and at intermediately and fixing of plaster of Paris on the panel provided as per design/ pattern given by the site officers and finishing the ceiling surface with some plaster of Paris materials etc. Necessary opening should be made for providing spot light florescent tubes in the ceiling by using kit ply 12mm thick and opening should be covered with Acrylic panel complying with standard specification and as directed by the departmental officers etc complete. (All materials should be got approved from the E.E before use on work)

125

-

-

... More
Manufacturing, Supplying and Fixing of Cornice work for Gyp Board False Ceiling complying with standard specification and as directed by the departmental officers etc complete. (All materials should be got approved from the E.E before use on work)

77

-

-

... More
Supply and Installation of PA Mixer Amplifier 240 W etc all complete complying with relevant standard specification and as directed by the departmental officers

1

-

-

... More
Supply and Installation of Cordless Mic UHF etc all complete complying with relevant standard specification and as directed by the departmental officers

1

-

-

... More
Supply and Installation of 30 W Wall Speaker etc all complete complying with relevant standard specification and as directed by the departmental officers

6

-

-

... More
Supply and laying of 2 Core 1.5 Sqmm shieelded Copper Speaker Wire etc all complete complying with relevant standard specification and as directed by the departmental officers

60

-

-

... More
Supply and Fixing Of 24W LED 4000K 2 x 2 Square Type Recessed Fitting For False Ceiling Works (Higher End Philips/ Havells/ Equivalent )etc all complete complying with relevant standard specification and as directed by the departmental officers

20

-

-

... More
Supplying and fixing of 48W LED Street Light Fitting with LED etc.,complete with ISI mark, complying with relevant standard specifications & as directed by the departmental officers. ( The Brand/Quality of fittings has to be got approved by the EE before fixing) (Higher end)

8

-

-

... More
Providing cuddappa slabs of following thickness for cupboards, wardrobes .shelves,of well polished on both sides smoothly including fixing with CM 1:3 (one of cement three of sand)12mm thick including cutting to the required size laying fixing in position and jointing with black oxide and finishing neatly etc. complete all complying with relevant specificartions and as directed by the departmental officers.(The Brand and quality of slab should be got approved from the EE before use) in the following floors

29

-

-

... More
Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase near wet riser using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick will be provided with tubular supports made of 304L Grade Stainless Steel pipe of tubular 25mm dia of 1.60mm thick welded to the railing. The supports will be grouted into the wall and provided with 93.00mm thick Stainless Steel circular base plate of 304 Grade. The rate shall included for grouting into concrete with necessary supporting arrangements the hand rail in floor polishing buffing, bonding, cutting, grinding, conveyance, welding charges, electrical charges, etc all complete complying with relevant standard specification and as directed by the departmental officers.(The quality of all the materials should be got approved before use on works)

11

-

-

... More
Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete. The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete

18

-

-

... More
Providing Cup-board Shutter with frame using termite / water proof plywood of 19mm thick over which laminated sheet of 0.8mm thick fixed inside the shutter and 1mm thick fixed in the outside of the shutter using fevicol along with necessary furniture fittings, such as, hydralic hinges, tower bolt, handles, multi purpose locks etc., as directed by the Departmental Officers. The design pattern, water proof plywood, laminate sheet and other materials should be got approved from the Executive Engineer befoe use on work.

61

-

-

... More
Supplying and Erecting Pull and Push Type Rolling Shutter with ISI make of approved size and section using 18 GI sheet. The shutter shall be painted with one coat of red oxide primer and the rate is inclusive of hood covers, transportation charges etc Manually Operated (up to 8 sqm. Area)

7.5

-

-

... More
Sub Total

-

-

-

... More
GST @ 18%

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.