Tamil Nadu Generation And Distribution Corporation Limited Tender
Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.
Tamil Nadu Generation And Distribution Corporation Limited - TANGEDCO Tender
Civil And Construction
Excavation
Eprocure
Opening Date29 Jul 2024
Closing Date20 Jan 2025
Tender Amount₹ 42,46,850
Costs
EMD
₹ 20,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_EB_467742_1Tender No
016/24-25 DT 21.06.2024.Tender Authority
Tamil Nadu Generation And Distribution Corporation Limited ViewPurchaser Address
-Website
http://https://www.tangedco.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Excavation of pit in Hard rock requires without blasting(where houses are located)
50
-
-
... More
Erection of RCC poles/PSC Poles /metal poles upto 27'(8.0m) pole by using JCB or manual
300
-
-
... More
Erection of RCC poles/PSC Poles/metal poles above 8 mtrs pole by using JCB or manual
200
-
-
... More
Erection of RSJ ,Rail and fabricated poles above 9.0m pole by using JCB or manual
100
-
-
... More
Erection of stay set complete
200
-
-
... More
Fixing of HT "V" cross arms (all types)/Channel cross arms/Guarding Cross arms
250
-
-
... More
Fixing of LT 3 phase cross arms
500
-
-
... More
Fixing of LT Single phase ph X arm
300
-
-
... More
Fixing of HT/LT TI fittings
300
-
-
... More
Fixing of HT Pin insulator 11 KV/22 KV
600
-
-
... More
Fixing of HT Pin insulator 33 KV
100
-
-
... More
Fixing of HT 11KV strain Disc
500
-
-
... More
Fixing of HT 22KV strain Disc
500
-
-
... More
Fixing of LT pin insulators
2000
-
-
... More
Fixing of LT shackle with MP
2000
-
-
... More
Fixing of Aluminium Knob
750
-
-
... More
Earthing of pole with pin including burying ,looping and binding
250
-
-
... More
Paving of Conductor, stringing, binding, jumpering etc., complete for lines with ACSR 7/4.09 mm
5
-
-
... More
Paving of Conductor, stringing, binding, jumpering etc., complete for lines with ACSR 7/3.35 mm or AAAC 7/3.15 mm conductor
25
-
-
... More
Paving of Conductor, stringing, binding, jumpering etc., complete for lines with ACSR 7/2.59 mm or AAAC 7/2.50mm conductor
50
-
-
... More
Structure Concreting , Concreting of poles with size (2'x2'x6') including cost of Cement ,jelly and Sand with a mixture of 1:3:6 and plastering of concrete with ratio 1:2
10
-
-
... More
Sleeve concreting with size (2'x2'x3') including cost of excavation Cement ,jelly and Sand with a mixture of 1:3:6 and plastering of concrete with ratio 1:2 including materials
25
-
-
... More
Stay concreting of Stay with Size 1.5' X 1.5' X 3.0' including cost of 40mm Cement,Jelly and sand (with supply) with mixture 1:3:6 along sleeve concreting and plastering of concrete portion above the ground level with ratio 1:2.
25
-
-
... More
ERECTION of Double Pole TRANSFORMER STRUCTURE COMPLETE inclusive of following works - Excavation of pole pits sizing 2' X 2' X 6'(2*475), erection of poles(2*550), Excavation of Stay pits (4*390) and Erection of stay set (4*210), erection of structure materials (Top Channel-Rs.250, Bed Channel-Rs.250,Cross with stud for bed Channel-Rs.120, Belting Angle-Rs.250) erection of AB switch (Rs.1000), HG Fuse (Rs.600) Structure Earthing complete (Rs.2100), Fixing of Open Type fuse units and feeder arrangements(Rs.900), HT/LT LAS fixing(Rs.350 and Rs.250) , Provision of bus-bar arrangement(Rs.500), Jumpering(Rs.400) Fixing of support inculator angle and erection of of 3 Nos pin insulators ( Rs.200) ( all T&P suchas crowbars, siling, DShackle etc., that must be brought by the contractor)(Labour for Structure Concreting, Stay Concreting,Painting, Fixing of name board / Danger Board, Erection of transformer, Transporting of Transformer , Fixing of DT meter ,Drilling of holes, Cutting,welding,alteration of clamps if anyand Provision of Earth pit collars are separately given).
25
-
-
... More
Dismantling of double pole Transformer structure complete- inclusive of following dismantling work pole 2Nos,stay pit 4 Nos, stay 4set,structure materials , AB switch, HG fuse set e, Structure earthing complete,earth pits ,earth tubs ,earth pipes,feeding arrangements with open type fuse unit,HT/LT LAS ,jumbers complete,support insulator,LTbus bar arrangements and danger board.( May be claimed seperately for any extra works)(all T&P such as crowbars,silling, Dshackle etc that must be brought by the contractor)
5
-
-
... More
Erection of Double Pole structure (D.P)- inclusive of following works - Excavation of pole pits sizing 2' X 2' X 6'(2*475), erection of poles(2*550), Excavation of Stay pits (4*390) and Erection of stay set (4*210), erection of structure materials (Top Channel-Rs.250) erection of AB switch (Rs.1000), Structure Earthing complete (Rs.1500), HT LAS fixing(Rs.350 ) , Jumpering (Rs.250) (all T&P suchas crowbars, siling, DShackle etc., that must be brought by the contractor)(Labour for Structure Concreting, Stay Concreting,Painting, Fixing of name board/Danger Board, (Drilling of holes, Cutting,welding,alteration of clamps if anyand Provision of Earth pit collars are separately given)
10
-
-
... More
Dismantling of double pole structure (D.P)complete inclusive of following dismantling work- poles, stay set complete,structure materials , AB switch, Structure earthing complete,earth pits ,earth tubs ,earth pipes,HT LAS ,jumbers complete,support insulator and danger board.( May be claimed seperately for any extra works) (all T&P such as crowbars,silling, Dshackle etc that must be brought by the contractor)
2
-
-
... More
Erection of Single pole Transformer Structure-inclusive of following works - Excavation of pole pit sizing 2' X 2' X 6'(1*475), erection of poles 1*550), Excavation of Stay pits (1*390) and Erection of stay set (1*210), erection of structure materials (Tapping Channel-Rs.150, Transformer centre set arrangements-Rs.350) erection of AB switch (Rs.900), HG Fuse (Rs.400) Structure Earthing complete (Rs.2000), Fixing of Open Type fuse units and feeder arrangements(Rs.450), HT/LT LAS fixing(Rs.350 and Rs.250) , Jumpering(Rs.300) (all T&P suchas crowbars, siling, DShackle etc., that must be brought by the contractor)(Labour for Structure Concreting, Stay Concreting,Painting, Fixing of name board/ Danger Board.Erection of transformer,transporting of transformer, LT cable arrangements, fixing of DT meter. Drilling of holes, Cutting,welding,alteration of clamps if anyand Provision of Earth pit collars are separately given)
10
-
-
... More
Dismantling of Single pole transformer structure complete -inclusive of following dismantling works - Pole, stay,structure materials ( tapping channel, transformer bed structure) , AB switch , HG fuse,structure earthing complete with 3 pits and earth loops, MCD box, HT/LT LAS, HT jumpers complete, LT cable arrangement and danger Board..( May be claimed seperately for any extra works) (all T&P such as crowbars,silling, Dshackle etc that must be brought by the contractor)
5
-
-
... More
Guarding arrangements with Flat guarding including fixing of 2Nos. Cross arms HT/LT
45
-
-
... More
Transport of poles/Materials/ conductors /DT/Metering Set and other materials( excluding loading and unloading charges.) below 8 Kms
100
-
-
... More
Transports of poles /Materials /Conductors and other materials(excluding loading and unloading charges) for above 8 Kms for addl. Kms( Irrespective of weight in Tonage/KM
2000
-
-
... More
Loading of metal poles ( all sizes)
200
-
-
... More
Loading of poles up to 8 M RCC/PSC poles
300
-
-
... More
Loading of poles above 8 m RCC/PSC poles
200
-
-
... More
UnLoading of poles up to 8 M RCC/PSC poles
300
-
-
... More
UnLoading of poles above 8 M RCC/PSC poles
200
-
-
... More
Unloading of metal poles ( all sizes)
200
-
-
... More
Transporting of poles from road side to pole pit Location including loading and unloading of poles by using JCB or Manual Up to 100 m
150
-
-
... More
Transporting of poles from road side to pole pit including loading and unloading of poles by using JCB or Manual above 100 m
225
-
-
... More
Loading or unloading of Transformer upto 100 KVA and Metering set
50
-
-
... More
Loading or unloading of Transformer above 100 KVA and up to 200 KVA
30
-
-
... More
Loading or unloading of Transformer above 200 KVA
30
-
-
... More
Resagging of HT/LT line with ACSR 7/4.09mm
1
-
-
... More
Re-sagging of HT / LT line with ACSR 7/3.35mm or AAAC 7 /3.15 mm conductor
15
-
-
... More
Re-sagging of HT / LT with ACSR 7/2.59mm or AAAC 7 /2.50 mm conductor
25
-
-
... More
Erection of street light including fixture fitting
75
-
-
... More
Erection of street light service
50
-
-
... More
Agriculture service fixing/service
25
-
-
... More
Releasing of grills from RCC poles
100
-
-
... More
Releasing of HTS wire from PSC pole
100
-
-
... More
Erection of new transformer for all capacities and HT metering set
50
-
-
... More
Releasing of single phase service wire and re-fixing.
375
-
-
... More
Releasing of 3 phase service wire (upto 50 HP) and re-fixing.
250
-
-
... More
Releasing of 3 phase service wire (above 50 HP) and re-fixing.
25
-
-
... More
Labour charges for alteration of Back clamps to suit for the works
250
-
-
... More
Labour charges for alteration of Stay clamps to suit for the works
125
-
-
... More
Releasing of ACSR/AAAC conductors from conductor drum and coiling ACSR 7/3.35, 7/2.59, AAAC 7/2.50, 7/3.15 MM (Per/Km.)
25
-
-
... More
Cutting of coconut leaves /per tree
500
-
-
... More
Cleaning of branches of tree per tree
500
-
-
... More
Drilling of hole in channel only 3/4" & 1" per hole
2000
-
-
... More
Cutting of flat
150
-
-
... More
Cutting of channel
100
-
-
... More
Cutting of Angle
100
-
-
... More
Cutting of pipe
50
-
-
... More
Dismandling of pole above 8.0 mtr
50
-
-
... More
Dismandling of pole up to 8.0 mtr
150
-
-
... More
Dismandling of 'V' X arm(all types),channel X arm,guarding X arm
50
-
-
... More
Dismandling of LT 3 phase X arm
250
-
-
... More
Dismandling of LT single phase X arm
150
-
-
... More
Dismandling of HT/LT TI fitting
50
-
-
... More
Dismandling of 11KV strain disc
100
-
-
... More
Dismandling of 11 KV/22KV pin insulator
150
-
-
... More
Dismandling of 33 KV pin insulator
50
-
-
... More
Dismandling of LT shackle
750
-
-
... More
Dismandling of LT pin insulator
500
-
-
... More
Dismandling of Aluminium knob
250
-
-
... More
Dismandling of stay set
150
-
-
... More
Dismandling of ACSR 7/3.35mm orAAAC 7/3.15 conductor
15
-
-
... More
Dismandling of ACSR 7/2.59mm or 7/2.11mm conductor
50
-
-
... More
Dismandling of street light service
50
-
-
... More
Loading of materials
50
-
-
... More
Unloading of materials
50
-
-
... More
Leading and stacking of materials
50
-
-
... More
Dismandling of MVL/SVL fitting
15
-
-
... More
Dismandling of 1x40w FTL fitting
25
-
-
... More
Provision of Earth pit collar
50
-
-
... More
Fixing of Danger Board
50
-
-
... More
Painting of all clamps and other materials and painting of structure pole for double pole structure.
20
-
-
... More
Painting of all clamps and other materials and painting of structure pole for single pole structure
20
-
-
... More
Painting of all clamps and other materials and painting of structure pole for DP structure
10
-
-
... More
Base concreting of transformer structure
100
-
-
... More
LT cable arrangements
10
-
-
... More
Provision of Distribution Transformer Name Board, ( Name of the 22/11 KV feeder , Name of the SS , Capacity of the DT).
50
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements