State Industries Promotion Corporation Of Tamil Nadu Limited Tender

Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.

State Industries Promotion Corporation Of Tamil Nadu Limited - SIPCOT Tender

Works
Civil And Construction
Civil Works Others
Eprocure
Opening Date14 Jun 2024
Closing Date1 Jul 2024
Tender Amount₹ 4,99,50,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Quarrying, wedging & chiseling the hard rock requiring blasting. 0 to 2.00m From Below GL etc., complete complying with standard specification and as directed by the SIPCOT officers

201

-

-

... More
Quarrying, wedging & chiseling the hard rock requiring blasting 2.00 to 3.00 m Below GL etc., complete complying with standard specification and as directed by the SIPCOT officers

402

-

-

... More
Quarrying, wedging & chiseling the hard rock requiring blasting. 3.00 to 4.00 m Below GL etc., complete complying with standard specification and as directed by the SIPCOT officers.

190

-

-

... More
Filling with clean river sand complying with standard specification including watering ramming and consolidation etc., complete complying with standard specification and as directed by the SIPCOT officers.

61

-

-

... More
Plain Cement Concrete 1:4:8 (One Cement, Four M-sand and Eight hard broken stone jelly) using 40 mm ISS size hard broken granite stone jelly for foundation including dewatering wherever if found necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc., complete complying with standard specification including cost and conveyance of all materials to site etc., complete complying with standard specification and as directed by the SIPCOT officers

61

-

-

... More
Providing and laying in position, Standardised Concrete Mix M-30 Grade in accordance with IS:456-2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cementcontent of 400 kg/m3 and maximum water cement ratio of 0.45, including admixture (plasticiser / superplasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m') 7670 kg. of sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming, etc., complete complying with standard specification and as directed by the SIPCOT officers The coarse and fine aggregates to be used should comply with the requirements of IS Standards and as directed by SIPCOT officers.

-

-

-

... More
Upto 1.50 m depth below G.L.

32

-

-

... More
Above 1.50 m upto 4.50 m depth below G.L.

255

-

-

... More
Upto 4.50 m height above G.L.

116

-

-

... More
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at above 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc., complete complying with the standard specificaiton. and as directed by SIPCOT officers.

-

-

-

... More
Upto 3.30 m below G.L. - Curved surface

375

-

-

... More
Upto 3.30 m below GL - Square column

20

-

-

... More
Upto 3.30 m above GL - Circular column

3.5

-

-

... More
up to 3.30 m above GL- curved surface

145

-

-

... More
up to 3.30 m above GL- Circular surface

2.5

-

-

... More
up to 3.30 m above GL- Square surface

7

-

-

... More
3.30 m to 4.30 m above G.L. - plane surface

58

-

-

... More
Painting the walls with two coats of cement paint over one coat of cement primer including preparation of surface curing, cost of primer etc. complete in all floors complying with standard specifications and as directed by SIPCOT officers. (The colour and shade of the cement paint shall be got approved by the Executive Engineer before use of work).

85

-

-

... More
Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel bars high strength deformed bars like RTS bars etc., conforming to FE 415 Grade for all RCC works including cost and conveyance of steel, binding wire to work site cost of fabrication ,labour charges for cleaning the rods , straightening , cutting, bending, tying grills, hoisting and placing the reinforcement in position before concreting , cost of binding wire , provision of space bars, cover blocks and all other incidental charges etc., complete complying with standard specification and as directed by SIPCOT officers.

220

-

-

... More
Supply ,delivery and fixing of RCC inside Access ladder of size 0.10x0.15x4.14m with steps of size 0.15x0.05x0.45m at an interval of 0.3m c/c using M30 concrete and RTS reinforcement with main rod of 10mm 4 nos. for Rib and 8mm stirrups at 0.15m c/c and with main rod of 8mm 2 nos. for each step with 8mm distributer at 0.1m c/c including cost of all materials , moulding charges, all labour charges finishing curing etc. complete complying with standard specification and as directed by the SIPCOT Officers. For storage depth of 3.00m

1

-

-

... More
Supplying and fixing in position of outside MS Ladder of 45cm clear wide made out of 50mm x 50mm x 6mm MS Angle for sides and steps in 16mm MS plain rods fixed at 30cm c/c welded jointed etc, providing with suitable side supports,clamps, locking arrangements provided with two coats of approved enamal paint over one coat of red oxide paint to access over roof top including bottom anchorage with bed block in CC1:2:4 using 20mm HBG at top and bottom of sump with suitable anchor bolt and transportation charges etc., complete complying with standard specification and as directed by SIPCOT officers.

1

-

-

... More
Supplying and fixing in position of 0.60 x 0.60 m size RCC Manhole on the roof slab including the cost of men & materials etc. complete complying with standard specification and as directed by the SIPCOT Officers.

2

-

-

... More
Supply , delivery and fixing of enameled water level indicator of approved design and pattern (graduation in metric system) with required all accessories etc. complete complying with standard specification and as directed by the SIPCOT Officers. (The rates including loading , unloading, conveyance charges but excluding GST)

1

-

-

... More
Reinforced Cement Concrete 1 : 1 1/2 : 3 mix ( one Cement one and half sand and three hard broken granite stone of 20mm size hard broken granite stone) for ventilator of dia. 0.45 m with 0.05m thick. including the cost of men & materials etc. complete complying with standard specification and as directed by the SIPCOT Officers.

4

-

-

... More
Refilling the foundation with excavated earth (other than sand) including watering, ramming, consolidating etc. complete complying with standard specification and as directed by the SIPCOT Officers.

125

-

-

... More
Providing Cut stone set in CM 1:3 (one cement and three M-sand) using well dressed cut stone supporting inlet pipe of size 0.45 x 0.45 x 0.15 m for service reservoir etc., complete as per standard specifications and as directed by SIPCOT officers.

1

-

-

... More
Painting SIPCOT Emblem in accordance with the size and specification as approved by the Board on the side wall of Sump including cost of all consumable ,one coat of base paint etc. complete complying with standard specification and as directed by the SIPCOT Officers.

3

-

-

... More
Provosion for pipe connection arrangements for inlet, Outlet, scour and overflow pipe arrangements including cost of pipes, Specials, valvesand labour charges for lifting, aligning and fixing etc. complete complying with standard specification and as directed by the SIPCOT Officers.

-

-

-

... More
INLET ARRANGEMENTS

-

-

-

... More
200 mm X 2.75 m C I D / F PIPE

661.1

-

-

... More
200 mm X 2.00 m C I D / F PIPE

120.2

-

-

... More
200 mm x 1.30 m C I D / F PIPE

60.1

-

-

... More
200 mm x 0.50 m C I D / F PIPE

30.05

-

-

... More
200 mm x 0.30 m C I D / F PIPE

30.05

-

-

... More
200 mm x 1.00 m C I D / F PIPE (Slotted)

240.4

-

-

... More
200 mm Duck foot Bend

74

-

-

... More
200 mm 90 degree D /F Bend

98

-

-

... More
200 mm C I D/ F Sluice Valve

1

-

-

... More
200 mm CI flgd / skt tail piece

53.3

-

-

... More
Surface box

33

-

-

... More
OVERFLOW ARRANGEMENTS

-

-

-

... More
200 mm X 2.75 m C I D / F PIPE

661.1

-

-

... More
200 mm x 1.30 m C I D / F PIPE

60.1

-

-

... More
200 mm x 1.00 m C I D / F PIPE

30.05

-

-

... More
200 mm Duck foot Bend

52

-

-

... More
200 mm 90 degree D /F Bend

49

-

-

... More
200 mm C I Bell mouth

23

-

-

... More
200 mm CI flgd / skt tail piece

53

-

-

... More
Supply and delivery of the following size of CI D/F Sluice Valve withwheel As per ISI 14846/2000 PN 1.0 etc. complete complying with standard specification and as directed by the SIPCOT Officers.

-

-

-

... More
200 mm C I D/ F Sluice Valve

1

-

-

... More
Laying of CI D/F pipes and specials to proper grade and alignment cxcluding cost of pipes and specials and jointing materials etc. complete complying with standard specification and as directed by the SIPCOT Officers.

12

-

-

... More
Jointing the CI Double flanged pipes and specials with rubber insertion to the required specifications with M.S bolts and nuts complete and testing the pipes to the required pressure with water etc. complete complying with standard specification and as directed by the SIPCOT Officers. (including cost of jointing materials)

1

-

-

... More
Supply and Delivery of following size of bolts and nuts and rubber insertion sheet etc. complete complying with standard specification and as directed by the SIPCOT Officers.

-

-

-

... More
20 mm dia X 100 mm length fully treadded bolts

136

-

-

... More
6 mm Rubber insertion Sheet

16

-

-

... More
Construction of masonry valve pit for fixing Sluice valves as per type design No.9/43. The foundation will be in PCC 1:4:8 and brick work in C:M 1:5 Plastering in cm 1:3 12mm thick and the pit provided with 100mm thick RCC 1:11/2:3cover slab. The rate should include earth work excavation in various soils met with at the site of work, refilling the pit after the construction of pit, cost of levelling course, brick work, plastering, cut stone RCC cover slab, cost of reinforcemet, fabrication charges and fixing the valves in position inside the pit, laying and jointing of CI pipes and specials etc., complete. The Jointing materials such as bolts nut washers, rubber insertion sheets white lead have to be procured and utilised by the contractor at his own cost etc. complete complying with standard specification and as directed by the SIPCOT Officers.

1

-

-

... More
Provsion for Rain Water Harvesting (Parapet wall over roof top)

-

-

-

... More
Brick Work in CM 1:6 (One cement and Six sand)using country bicks of size 8.75" x 4.25" x 2" including for parapet wall alround roof slab etc. complete complying with standard specification and as directed by the SIPCOT Officers.

0.64

-

-

... More
Plastering in CM 1:5 (One cement and five sand) - 12mm thick alround papapet over roof slab icluding finishing curing etc. complete complying with standard specification and as directed by the SIPCOT Officers.

17.83

-

-

... More
Plastering in CM 1:3 (One cement and three sand) - over roof slab of reservoir with proper gradient of 1/50 for drain the rain water at the center of roof slab by cnnecting the rain water harvesting pipes with over flow pipe as per type design etc. complete complying with standard specification and as directed by the SIPCOT Officers.

251.65

-

-

... More
Painting the walls with two coats of cement paint over one coat of cement primer including preparation of surface curing and including cost of primer etc., complete in all floors complying with standard specifications and as directed by SIPCOT officers. (The colour and shade of the cement paint shall be got approved by the Executive Engineer before use of work).

12.21

-

-

... More
Supply and fixing of pvc gratings of size 20x20cm for fixing in the roof of the reservoir etc. complete complying with standard specification and as directed by the SIPCOT Officers.

1

-

-

... More
RECHARGE/SOAKOIT FOR RAIN WATER HARVESTING FOR RESERVOIR WITH FLAT ROOF.

-

-

-

... More
Earth work excavation and depositing on bank with initial lead of 10M and initial lift of 2M for Hard Stiff clay, Stiff black cotton,hard red earth, shales, murram, gravel, stoney earth and earth mixed with small sized boulders and hard gravely soil as pe

8.82

-

-

... More
Brick work in CM 1:6 (One cement and six sand) using country bricks of size 8.75" x4.25"x2" including curing etc., complete for parapet well alround roof slab as directed by TWAD Board officers.

1.45

-

-

... More
Supply,delivery and filling of clean river course sand / M sand for the recharge piot s per type design.

0.47

-

-

... More
Supply,delivery and filling of 20 mm size brick bats as per type design.

1.88

-

-

... More
Supply,deliery ad filling of 40mm size brick batsas per type design.

3.46

-

-

... More
Supply,deliery and fixing of splash pad of size 500 x 500 x 50mm at the over flow junction point with recharge pit.

1

-

-

... More
Cost of pipes - 110mm OD UPVC - 4 Ksc

18

-

-

... More
Fixing pvc pipes with clamps

1

-

-

... More
(PART - B) - Construction of 10.00 Lakh litres Sump (1No) in Nallaganakothapalli Village

-

-

-

... More
Earth work excavation for foundation in all classes of soils and sub-soils and to full depth as may be directed except in hard rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 10 mts and initial lift of 2 mts. and clearing and levelling the site, etc., complete complying with standard specification and as directed by SIPCOT Officers.

-

-

-

... More
Hard stiff clay, stiff black cotton, hard red earth, shales, murram, gravel, stoney earth and earth mixed with small size boulders and hard gravelly soil ( SS 20B) I-st depth of 2.00 m etc., complete complying with standard specification and as directed by the SIPCOT officers

605

-

-

... More
Quarrying, wedging & chiseling the hard rock requiring blasting. 0 to 2.00m From Below GL etc., complete complying with standard specification and as directed by the SIPCOT officers

201

-

-

... More
Quarrying, wedging & chiseling the hard rock requiring blasting 2.00 to 3.00 m Below GL etc., complete complying with standard specification and as directed by the SIPCOT officers

402

-

-

... More
Quarrying, wedging & chiseling the hard rock requiring blasting. 3.00 to 4.00 m Below GL etc., complete complying with standard specification and as directed by the SIPCOT officers.

190

-

-

... More
Filling with clean river sand complying with standard specification including watering ramming and consolidation etc., complete complying with standard specification and as directed by the SIPCOT officers.

61

-

-

... More
Plain Cement Concrete 1:4:8 (One Cement, Four M-sand and Eight hard broken stone jelly) using 40 mm ISS size hard broken granite stone jelly for foundation including dewatering wherever if found necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc., complete complying with standard specification including cost and conveyance of all materials to site etc., complete complying with standard specification and as directed by the SIPCOT officers

61

-

-

... More
Providing and laying in position, Standardised Concrete Mix M-30 Grade in accordance with IS:456-2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cementcontent of 400 kg/m3 and maximum water cement ratio of 0.45, including admixture (plasticiser / superplasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m') 7670 kg. of sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming, etc., complete complying with standard specification and as directed by the SIPCOT officers The coarse and fine aggregates to be used should comply with the requirements of IS Standards and as directed by SIPCOT officers.

-

-

-

... More
Upto 1.50 m depth below G.L.

32

-

-

... More
Above 1.50 m upto 4.50 m depth below G.L.

255

-

-

... More
Upto 4.50 m height above G.L.

116

-

-

... More
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at above 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc., complete complying with the standard specificaiton. and as directed by SIPCOT officers.

-

-

-

... More
Upto 3.30 m below G.L. - Curved surface

375

-

-

... More
Upto 3.30 m below GL - Square column

20

-

-

... More
Upto 3.30 m above GL - Circular column

3.5

-

-

... More
up to 3.30 m above GL- curved surface

145

-

-

... More
up to 3.30 m above GL- Circular surface

2.5

-

-

... More
up to 3.30 m above GL- Square surface

7

-

-

... More
3.30 m to 4.30 m above G.L. - plane surface

58

-

-

... More
Painting the walls with two coats of cement paint over one coat of cement primer including preparation of surface curing, cost of primer etc. complete in all floors complying with standard specifications and as directed by SIPCOT officers. (The colour and shade of the cement paint shall be got approved by the Executive Engineer before use of work).

85

-

-

... More
Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel bars high strength deformed bars like RTS bars etc., conforming to FE 415 Grade for all RCC works including cost and conveyance of steel, binding wire to work site cost of fabrication ,labour charges for cleaning the rods , straightening , cutting, bending, tying grills, hoisting and placing the reinforcement in position before concreting , cost of binding wire , provision of space bars, cover blocks and all other incidental charges etc., complete complying with standard specification and as directed by SIPCOT officers.

220

-

-

... More
Supply ,delivery and fixing of RCC inside Access ladder of size 0.10x0.15x4.14m with steps of size 0.15x0.05x0.45m at an interval of 0.3m c/c using M30 concrete and RTS reinforcement with main rod of 10mm 4 nos. for Rib and 8mm stirrups at 0.15m c/c and with main rod of 8mm 2 nos. for each step with 8mm distributer at 0.1m c/c including cost of all materials , moulding charges, all labour charges finishing curing etc. complete complying with standard specification and as directed by the SIPCOT Officers. For storage depth of 3.00m

1

-

-

... More
Supplying and fixing in position of outside MS Ladder of 45cm clear wide made out of 50mm x 50mm x 6mm MS Angle for sides and steps in 16mm MS plain rods fixed at 30cm c/c welded jointed etc, providing with suitable side supports,clamps, locking arrangements provided with two coats of approved enamal paint over one coat of red oxide paint to access over roof top including bottom anchorage with bed block in CC1:2:4 using 20mm HBG at top and bottom of sump with suitable anchor bolt and transportation charges etc., complete complying with standard specification and as directed by SIPCOT officers.

1

-

-

... More
Supplying and fixing in position of 0.60 x 0.60 m size RCC Manhole on the roof slab including the cost of men & materials etc. complete complying with standard specification and as directed by the SIPCOT Officers.

2

-

-

... More
Supply , delivery and fixing of enameled water level indicator of approved design and pattern (graduation in metric system) with required all accessories etc. complete complying with standard specification and as directed by the SIPCOT Officers. (The rates including loading , unloading, conveyance charges but excluding GST)

1

-

-

... More
Reinforced Cement Concrete 1 : 1 1/2 : 3 mix ( one Cement one and half sand and three hard broken granite stone of 20mm size hard broken granite stone) for ventilator of dia. 0.45 m with 0.05m thick. including the cost of men & materials etc. complete complying with standard specification and as directed by the SIPCOT Officers.

4

-

-

... More
Refilling the foundation with excavated earth (other than sand) including watering, ramming, consolidating etc. complete complying with standard specification and as directed by the SIPCOT Officers.

125

-

-

... More
Providing Cut stone set in CM 1:3 (one cement and three M-sand) using well dressed cut stone supporting inlet pipe of size 0.45 x 0.45 x 0.15 m for service reservoir etc., complete as per standard specifications and as directed by SIPCOT officers.

1

-

-

... More
Painting SIPCOT Emblem in accordance with the size and specification as approved by the Board on the side wall of Sump including cost of all consumable ,one coat of base paint etc. complete complying with standard specification and as directed by the SIPCOT Officers.

3

-

-

... More
Provosion for pipe connection arrangements for inlet, Outlet, scour and overflow pipe arrangements including cost of pipes, Specials, valvesand labour charges for lifting, aligning and fixing etc. complete complying with standard specification and as directed by the SIPCOT Officers.

-

-

-

... More
INLET ARRANGEMENTS

-

-

-

... More
200 mm X 2.75 m C I D / F PIPE

661.1

-

-

... More
200 mm X 2.00 m C I D / F PIPE

120.2

-

-

... More
200 mm x 1.30 m C I D / F PIPE

60.1

-

-

... More
200 mm x 0.50 m C I D / F PIPE

30.05

-

-

... More
200 mm x 0.30 m C I D / F PIPE

30.05

-

-

... More
200 mm x 1.00 m C I D / F PIPE (Slotted)

240.4

-

-

... More
200 mm Duck foot Bend

74

-

-

... More
200 mm 90 degree D /F Bend

98

-

-

... More
200 mm C I D/ F Sluice Valve

1

-

-

... More
200 mm CI flgd / skt tail piece

53.3

-

-

... More
Surface box

33

-

-

... More
OVERFLOW ARRANGEMENTS

-

-

-

... More
200 mm X 2.75 m C I D / F PIPE

661.1

-

-

... More
200 mm x 1.30 m C I D / F PIPE

60.1

-

-

... More
200 mm x 1.00 m C I D / F PIPE

30.05

-

-

... More
200 mm Duck foot Bend

52

-

-

... More
200 mm 90 degree D /F Bend

49

-

-

... More
200 mm C I Bell mouth

23

-

-

... More
200 mm CI flgd / skt tail piece

53

-

-

... More
Supply and delivery of the following size of CI D/F Sluice Valve withwheel As per ISI 14846/2000 PN 10.0 etc. complete complying with standard specification and as directed by the SIPCOT Officers.

-

-

-

... More
200 mm C I D/ F Sluice Valve

1

-

-

... More
Laying of CI D/F pipes and specials to proper grade and alignment cxcluding cost of pipes and specials and jointing materials etc. complete complying with standard specification and as directed by the SIPCOT Officers.

12

-

-

... More
Jointing the CI Double flanged pipes and specials with rubber insertion to the required specifications with M.S bolts and nuts complete and testing the pipes to the required pressure with water etc. complete complying with standard specification and as directed by the SIPCOT Officers. (including cost of jointing materials)

1

-

-

... More
Supply and Delivery of following size of bolts and nuts and rubber insertion sheet etc. complete complying with standard specification and as directed by the SIPCOT Officers.

-

-

-

... More
20 mm dia X 100 mm length fully treadded bolts

136

-

-

... More
6 mm Rubber insertion Sheet

16

-

-

... More
Construction of masonry valve pit for fixing Sluice valves as per type design No.9/43. The foundation will be in PCC 1:4:8 and brick work in C:M 1:5 Plastering in cm 1:3 12mm thick and the pit provided with 100mm thick RCC 1:11/2:3cover slab. The rate should include earth work excavation in various soils met with at the site of work, refilling the pit after the construction of pit, cost of levelling course, brick work, plastering, cut stone RCC cover slab, cost of reinforcemet, fabrication charges and fixing the valves in position inside the pit, laying and jointing of CI pipes and specials etc., complete. The Jointing materials such as bolts nut washers, rubber insertion sheets white lead have to be procured and utilised by the contractor at his own cost etc. complete complying with standard specification and as directed by the SIPCOT Officers.

1

-

-

... More
Provsion for Rain Water Harvesting (Parapet wall over roof top)

-

-

-

... More
Brick Work in CM 1:6 (One cement and Six sand)using country bicks of size 8.75" x 4.25" x 2" including for parapet wall alround roof slab etc. complete complying with standard specification and as directed by the SIPCOT Officers.

0.64

-

-

... More
Plastering in CM 1:5 (One cement and five sand) - 12mm thick alround papapet over roof slab icluding finishing curing etc. complete complying with standard specification and as directed by the SIPCOT Officers.

17.83

-

-

... More
Plastering in CM 1:3 (One cement and three sand) - over roof slab of reservoir with proper gradient of 1/50 for drain the rain water at the center of roof slab by cnnecting the rain water harvesting pipes with over flow pipe as per type design etc. complete complying with standard specification and as directed by the SIPCOT Officers.

251.65

-

-

... More
Painting the walls with two coats of cement paint over one coat of cement primer including preparation of surface curing and including cost of primer etc., complete in all floors complying with standard specifications and as directed by SIPCOT officers. (The colour and shade of the cement paint shall be got approved by the Executive Engineer before use of work)

12.21

-

-

... More
Supply and fixing of pvc gratings of size 20x20cm for fixing in the roof of the reservoir etc. complete complying with standard specification and as directed by the SIPCOT Officers.

1

-

-

... More
RECHARGE/SOAKOIT FOR RAIN WATER HARVESTING FOR RESERVOIR WITH FLAT ROOF.

-

-

-

... More
Earth work excavation and depositing on bank with initial lead of 10M and initial lift of 2M for Hard Stiff clay, Stiff black cotton,hard red earth, shales, murram, gravel, stoney earth and earth mixed with small sized boulders and hard gravely soil as pe

8.82

-

-

... More
Brick work in CM 1:6 (One cement and six sand) using country bricks of size 8.75" x4.25"x2" including curing etc., complete for parapet well alround roof slab as directed by TWAD Board officers.

1.45

-

-

... More
Supply,delivery and filling of clean river course sand for the recharge piot s per type design.

0.47

-

-

... More
Supply,delivery and filling of 20 mm size brick bats as per type design.

1.88

-

-

... More
Supply,deliery ad filling of 40mm size brick bats as per type design.

3.46

-

-

... More
Supply,deliery and fixing of splash pad of size 500 x 500 x 50mm at the over flow junction point with recharge pit.

1

-

-

... More
Cost of pipes - 110mm OD UPVC - 4 Ksc

18

-

-

... More
Fixing pvc pipes with clamps

1

-

-

... More
(PART C) - Construction of 5.00 Lakh litres Capacity OHT (1No) with 12.00 m Staging in Maruthandapalli Village

-

-

-

... More
Earthwork excavation and deposting on bank with an initial lead of 10 m and lift of 2 m in head stiff clay blcak cotton, hard red earth, shales, murram, ordinary gravel, stoney earth and earth mixed with small size boulders for fountadion SS 20B etc., complete complying with standred specification and as directed by SIPCOT Officers.

32

-

-

... More
Hard rock measured in solid including blasting and stacking etc., complete as per standard specification and as directed by SIPCOT officers.

-

-

-

... More
0 to 2 m from below GL

134

-

-

... More
2 to 3 m From Below GL

74

-

-

... More
3 to 4 m From Below GL

45

-

-

... More
Filling the bottom of foundation with M.sand in layers of 15cm thick,watered well rammed and consolidated etc. complete complying with standard specification and as directed by the Officers. Below G.L 0 to 1.50 m

15

-

-

... More
Plain Cement Concrete 1:4:8 (One Cement, Four M-sand and Eight hard broken stone jelly) using 40 mm ISS size hard broken granite stone jelly for foundation including dewatering wherever if found necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc., complete complying with standard specification including cost and conveyance of all materials to site and as directed by SIPCOT officers.

-

-

-

... More
Below GL 1.50 m to 4.50 m

9

-

-

... More
Below GL 0 to 1.50 m

7.5

-

-

... More
Providing and laying in position, Standardised Concrete Mix M-30 Grade in accordance with IS:456-2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cementcontent of 400 kg/m3 and maximum water cement ratio of 0.45, including admixture (plasticiser / superplasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m') 7670 kg. of sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards and as directed by SIPCOT officers.

-

-

-

... More
Up to 1.5 m to 4.50 m Below GL

37

-

-

... More
Up to 1.5m below GL

25

-

-

... More
0 to 1 m above GL

6

-

-

... More
1 to 4.50 Above GL (Tie Beam)

32

-

-

... More
4.50 to 7.32 m For Column

30

-

-

... More
7.32 to 10.98 m Height for Column above Gl ( up to 8.775 m)

33

-

-

... More
10.98 to 14.64 m Height for Column above Gl

74

-

-

... More
0-4.50 m above floor slab 0 to 1.00m Above flatform

17

-

-

... More
1.00 to 4.50 Above GL

72

-

-

... More
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at above 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc., complete complying with the standard specificaiton. and as directed by SIPCOT officers.

-

-

-

... More
0 to 3.30 below GL

-

-

-

... More
Plane Surface

156

-

-

... More
Square Surface

94

-

-

... More
Circular Surface

4.63

-

-

... More
0 to 3.30 Above GL

-

-

-

... More
Square Column

105.6

-

-

... More
Circular Column

5.18

-

-

... More
0 to 3.30 m height form above GL

-

-

-

... More
Plane Surface

125.08

-

-

... More
3.30 to 4.30 m for Column

-

-

-

... More
Circular surface

1.57

-

-

... More
square Column

32

-

-

... More
4.30 to 5.30m for Column

-

-

-

... More
Circular surface

1.57

-

-

... More
square Column

32

-

-

... More
5.30 to 6.30 m for Column

-

-

-

... More
Circular Column

1.57

-

-

... More
square Column

32

-

-

... More
Tie beam at (TB)+6.00 m Level (6.075 to 6.30m m Height ) Plane Surface

44

-

-

... More
6.30 to 7.30 m for Column

-

-

-

... More
Circular Column

1.57

-

-

... More
square Column

32

-

-

... More
7.30 to 8.30 m height for Column

-

-

-

... More
Circular Column

1.57

-

-

... More
square Column

32

-

-

... More
8.30 to 9.30 m Height for Column ( Up to 8.775 m Height)

-

-

-

... More
Circular Column

1.57

-

-

... More
square Column

32

-

-

... More
Tie beam at (TB) + 9.225 m Level (8.30 to 9.30m m Height) - Plane Surface

44

-

-

... More
9.30 to 10.30 m Height for Column

-

-

-

... More
Circular Column

1.57

-

-

... More
square Column

32

-

-

... More
10.30 to 11.10 m Height for Column

-

-

-

... More
Circular Column

1.26

-

-

... More
square Column

25.6

-

-

... More
Grid beam at (TB) + 11.00 m Level (11.30 to 12.30 m m Height)

-

-

-

... More
Curved Surface

879.67

-

-

... More
0-3.30m From Floor Slab (above G.L.)

-

-

-

... More
Curved Surface

285.67

-

-

... More
square Column

52.8

-

-

... More
3.30 m to 4.30 m Height

-

-

-

... More
Curved Surface

13.29

-

-

... More
square Column

5.6

-

-

... More
Roof Slab at + 3.95 m level

-

-

-

... More
Curved Surface

18.34

-

-

... More
Plane Surface

122.62

-

-

... More
Painting the walls with two coats of cement paint over one coat of cement primer including preparation of surface curing and including cost of primer etc., complete in all floors complying with standard specifications and as directed by SIPCOT officers. (The colour and shade of the cement paint shall be got approved by the Executive Engineer before use of work).

1020

-

-

... More
Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel bars high strength deformed bars like RTS bars etc.., conforming to FE 415 Grade for all RCC works including cost and conveyance of steel, binding wire to work site cost of fabrication ,labour charges for cleaning the rods, straightening , cutting, bending, tying grills, hoisting and placing the reinforcement in position before concreting , cost of binding wire , provision of space bars, cover blocks and all other incidental charges etc., complete complying with standard specification and as directed by SIPCOT officers.

503.08

-

-

... More
Construction of RCC Sprial stair case in RCC M30 design mix concrete of 1.80 m dia required height for approach to the roof of service reservoir with RCC hand rails as per type design of in cluding necessary earth work excavation in various classification of soils met with at the site of work for providing fountation concrete CC 1:4:8mix, RCC footing M30 Mix, GL Platform etc., including cost of steel reinforcement , fabrication charges, scoffholding, centring precastring, , cemeant painting the surfaces etc complete,. vide seperate sheet annexed. (Spiral Stircase for 12 M Staging)

-

-

-

... More
Earthwork excavation and depositing on bank with initial lead and lift (a)in hard stiff clay,black cotton soil, hard red earth,shales, muram,gravel,stoney earth and earth mixed with 50% fair size boulders.

0.97

-

-

... More
Removing hard rock by wedging, chiselling & trimming to proper shape where blasting is prohibited with initial lead of 10 m and initial lift of 1 m

4.86

-

-

... More
Msand filling for foundation including the cost of sand,ramming and consolidation etc complete

0.49

-

-

... More
Plain Cement Concrete 1:4:8 (One Cement, Four M-sand and Eight hard broken stone jelly) using 40 mm ISS size hard broken granite stone jelly for foundation including dewatering wherever if found necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc., complete complying with standard specification including cost and conveyance of all materials to site and as directed by SIPCOT officers.

0.95

-

-

... More
Reinforced Cement concrete in 1:11/2:3 using 20mm ISS graded HBG metal including cost and conveyance of all materials to site and cost of cement at site including soft water, labour charges for form work, centering, mixing, transporting, laying and curing concrete, tools and plants and incidental charges excluding cost of steel etc., complete as per standard specification and as directed by SIPCOT officers.

-

-

-

... More
Column upto G.L.

0.84

-

-

... More
Column upto 4.50m from G.L.

0.39

-

-

... More
Column upto 4.50m - 7.32 m from G.L.

0.27

-

-

... More
Column upto 7.32m - 10.98m from G.L.

0.33

-

-

... More
Column upto 10.98m-14.64m from G.L.

0.33

-

-

... More
Column upto 14.64m-18.3m from G.L.

0.33

-

-

... More
Landing Slab at top of S.R

0.1

-

-

... More
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc., Complete complying with standard specification and as directed by SIPCOT Officers.

-

-

-

... More
Rectangular portion below G.L.

0.9

-

-

... More
Column upto G.L.

0.94

-

-

... More
Landing slab @20 m

1.2

-

-

... More
Reinforced Cement concrete in 1:11/2:3 using 20mm ISS graded HBG metal including cost and conveyance of all materials to site and cost of cement at site including soft water, labour charges for form work, centering, mixing, transporting, laying and curing concrete, tools and plants and incidental charges excluding cost of steel etc., complete as per standard specification and as directed by SIPCOT officers. for steps

-

-

-

... More
Below G.L

6.66

-

-

... More
Reinforced Cement concrete in 1:11/2:3 using 20mm ISS graded HBG metal including cost and conveyance of all materials to site and cost of cement at site including soft water, labour charges for form work, centering, mixing, transporting, laying and curing concrete, tools and plants and incidental charges excluding cost of steel etc., complete as per standard specification and as directed by SIPCOT officers. for Jally work

1.66

-

-

... More
Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel bars high strength deformed bars like RTS bars etc.., conforming to FE 415 Grade for all RCC works including cost and conveyance of steel, binding wire to work site cost of fabrication ,labour charges for cleaning the rods , straightening , cutting, bending, tying grills, hoisting and placing the reinforcement in position before concreting , cost of binding wire , provision of space bars, cover blocks and all other incidental charges etc., complete complying with standard specification and as directed by SIPCOT officers.

12.02

-

-

... More
Charges for mould for casting steps

60

-

-

... More
Charges for mould for casting handrails posts

40

-

-

... More
Charges for mould for casting jollywork

40

-

-

... More
Providing scafolding for a length of 4m wide

1

-

-

... More
Lifting the steps and jolly works by means of pulley block and structing in position including hire charge for pulley block.

1

-

-

... More
Provision for fixing the staircase with columns at brace level with MS clamps (or) with RCC beams.

1

-

-

... More
Providing M.S Grill gate at roof level woth lock

1

-

-

... More
Provision for finishing works

1

-

-

... More
Refilling the foundation with excavated earth (other than sand) including watering, ramming, consolidating etc. complete complying with standard specification and as directed by the SIPCOT Officers.

3.55

-

-

... More
Providing and fixing RCC inside access ladder of approved pattern and design in RCC 1:11/2:3 (One cement and one and half sand and three HBG stone of 20mm size ISS gauge) 0.40m width, 0.10m thickness, 0.12m breadth for side post, 0.05m thickness 0.12m breadth for steps with suitable inclination including cost of cement, reinforcement centering, finishing, curing etc., complete and as directed by SIPCOT Officers.

3

-

-

... More
Providing RCC ventilating arrangements etc. complete complying with standard specification and as directed by the SIPCOT Officers.

3

-

-

... More
Supplying and fixing in position of cut stone of size 0.45m x 0.45m x 0.15m at site in CM 1:3(One part cement and three part sand) at bottom of inlet pipe inside the Sump the suitable size and as directed by the SIPCOT Officers.

1

-

-

... More
Supply, delivery and fixing in position of 0.60x0.60 m C.I manhole frame and cover heavy duty approved patten at the roof slab and as directed . the manhole frame and cover should of light etc. complete complying with standard specification and as directed by the SIPCOT Officers.

3

-

-

... More
Labour charges for Painting Sipcot Emblem in accordance with the size and specifications as approved by the Board on the Service Reservoirs including cost of all consumables , one coat of base paint, scaffolding charges including painting NRDWP logo on the Service Reservoir etc. complete complying with standard specification and as directed by the SIPCOT Officers.

9

-

-

... More
Refilling the sides of foundation with excavated earth (other than sand) in layers of 15cm thick,watered well rammed and consolidated etc. complete complying with standard specification removing and spreading the surplus earth at the places shown etc. complete complying with standard specification and as directed by the SIPCOT Officers.

-

-

-

... More
As per item 1 a+1 b+ 1c+1d (32+134+74+45)=285m³. Less item no : 2. ( D/F sand filling quantity=-15m³). 3.(D/F P.C.C 1:4:8 quantity=16.50m³) 4.(D/F column R.C.C quantity up to GL=37+25=62m³) Total (285-15-16.50-62=191.50) add Extra 0.50 =192.00m³

192

-

-

... More
Parapet Wall Over roof slab for rain water harvesting arrangement etc. complete complying with standard specification and as directed by the SIPCOT Officers.

-

-

-

... More
Brick Work in CM 1:6 (One cement and Six sand)using country bicks of size 8.75" x 4.25" x 2" including for parapet wall alround roof slab etc. complete complying with standard specification and as directed by the SIPCOT Officers.

0.5

-

-

... More
Plastering in CM 1:5 (One cement and five sand) - 12mm thick alround papapet over roof slab icluding finishing curing etc. complete complying with standard specification and as directed by the SIPCOT Officers.

13.82

-

-

... More
Plastering in CM 1:3 (One cement and three sand) - over roof slab of reservoir with proper gradient of 1/50 for drain the rain water at the center of roof slab by cnnecting the rain water harvesting pipes with over flow pipe as per type design etc. complete complying with standard specification and as directed by the SIPCOT Officers.

149.37

-

-

... More
Painting the walls with two coats of cement paint over one coat of cement primer including preparation of surface curing, cost of primer etc. complete in all floors complying with standard specifications and as directed by SIPCOT officers. (The colour and shade of the cement paint shall be got approved by the Executive Engineer before use of work).

9.49

-

-

... More
Supply and fixing of pvc gratings of size 20x20cm for fixing in the roof of the reservoir. etc. complete complying with standard specification and as directed by the SIPCOT Officers.

1

-

-

... More
RECHARGE/SOAKOIT FOR RAIN WATER HARVESTING FOR RESERVOIR WITH FLAT ROOF.

-

-

-

... More
Earth work excavation and depositing on bank with initial lead of 10M and initial lift of 2M for Hard Stiff clay, Stiff black cotton,hard red earth, shales, murram, gravel, stoney earth and earth mixed with small sized boulders and hard gravely soil etc. complete complying with standard specification and as directed by the SIPCOT Officers.

8.82

-

-

... More
Brick work in CM 1:6 (One cement and six sand) using country bricks of size 8.75" x4.25"x2" including curing etc. complete complying with standard specification and as directed by the SIPCOT Officers.

1.45

-

-

... More
Supply,delivery and filling of clean river course sand for the recharge piot s per type design. etc. complete complying with standard specification and as directed by the SIPCOT Officers.

0.47

-

-

... More
Supply,delivery and filling of 20 mm size brick bats as per type design. etc. complete complying with standard specification and as directed by the SIPCOT Officers.

1.88

-

-

... More
Supply,deliery ad filling of 40mm size brick batsas per type design. etc. complete complying with standard specification and as directed by the SIPCOT Officers.

3.45

-

-

... More
Supply,deliery and fixing of splash pad of size 500 x 500 x 50mm at the over flow junction point with recharge pit. etc. complete complying with standard specification and as directed by the SIPCOT Officers.

1

-

-

... More
Cost of pipes - 110mm OD UPVC - 4 Ksc etc. complete complying with standard specification and as directed by the SIPCOT Officers.

18

-

-

... More
Fixing pvc pipes with clamps etc. complete complying with standard specification and as directed by the SIPCOT Officers.

1

-

-

... More
Supply Top bases Lightning Arrester – SIRUS Supply of ESE lightning air terminal with the below technical parameters. • Stainless Steel material (304 L) – suitable for corrosive environments • Delta T = 60 micro seconds • HIZAL lab tested as per NF C 17-102 (2011) standard • Tested for 204 KA peak impulse current • Ipeak-avg = 102 KA • Protection radius = 107 mtrs (Level 4 / Standard) Model: SIRUS,Supply of 17.2mm Dia Copper Bonded Rod 3 Mtrs Long with SS Unit , Bolt and 50Kg EFC,MOUNTING STRUCTURE Standard Mounting Structure of 6 mtrs height with GI pipe and base plate suitable for roof mounting,Control Analogue Type,Supply of 25 x3 Copper Strip,Installation of ESE Lightning Arrester 1) Installation of Mounting Structure 2) Installation of Lightning Rod 3) Laying of Down conductor Installation of Earth Electrodes 4) Installation of earth electrode,Scaffolding Charges.

1

-

-

... More
Special & Adavnce Features Can be View Water Level using Inbuilt Application from Android Mobile and Computers ("I -Talk") Easy to verify Water Flow & Pervious Date/Month/Year Datas Can be checkedUsed Solar Panel Monocrystalline & No EB Required.LED Display Unit (Hibeam Red Color LED Light).Inbuilt Buffer Alarm for Water High and Low.Inbuilt Lithium Battery Backup For 2 Days (3 Years Warranty).CallBack for User when Water is at High or Low level.100% Message to user for Waterlevel 70% & 20%,Scaffolding Charges. etc. complete complying with standard specification and as directed by the SIPCOT Officers.

1

-

-

... More
Supply and fixing of precast RCC handrails of 0.91 m height in M 20 concrete over the top of the roof slab of approved pattern and resign including the cost of concrete mix, Reinforecment, Centering and labour charges etc complete Opening of stair case. etc. complete complying with standard specification and as directed by the SIPCOT Officers.

45

-

-

... More
Provision for Air vent pipes inner dia 0.40 m in M 30 with RCC rods and mould including supply and Delivery of weld mesh 10 cm X 10 cM in 10 Kauge Sq with cost of labour for lifting, fixing etc. complete complying with standard specification and as directed by the SIPCOT Officers.

4

-

-

... More
(PART D) - CONSTRUCTION OF 5.00 LAKH LITRES CAPACITY OHT (1No) WITH 16.00M STAGING IN NALLAGANAKOTHAPALLI VILLAGE

-

-

-

... More
Clearing of light jungles and removing away from site cetc. complete complying with standard specification and as directed by the SIPCOT Officers.

3500

-

-

... More
Earthwork excavation and depositing on bank with an initial lead of 10 m and lift of 2m in Hard stiff clay blcak cotton, hard red earth, shales, murram, ordinary gravel, stoney earth and earth mixed with small size boulders for foundation SS 20B etc. complete complying with standard specification and as directed by the SIPCOT Officers.

188.64

-

-

... More
Hard rock measured in solid including blasting and stacking etc. complete complying with standard specification and as directed by the SIPCOT Officers.

-

-

-

... More
2.00 to 3.00 m Below GL

85.46

-

-

... More
3.00 to 4.00 m Below GL

85.46

-

-

... More
4.00 to 5.00 m Below GL

51.28

-

-

... More
Filling the bottom of foundation with M.sand in layers of 15cm thick,watered well rammed and consolidated etc. complete complying with standard specification and as directed by the SIPCOT Officers.

15

-

-

... More
Plain Cement Concrete 1:4:8 (One Cement, Four M-sand and Eight hard broken stone jelly) using 40 mm ISS size hard broken granite stone jelly for foundation including dewatering wherever if found necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing including cost and conveyance of all materials to site etc., complete complying with standard specification and as directed by SIPCOT officers.

-

-

-

... More
Below G.L 1.50 m to 4.50 m

8.55

-

-

... More
Below G.L 0 to 1.50 m

5.64

-

-

... More
Providing and laying in position, Standardised Concrete Mix M-30 Grade in accordance with IS:456-2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cementcontent of 400 kg/m3 and maximum water cement ratio of 0.45, including admixture (plasticiser / superplasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m') 7670 kg. of sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards and as directed by SIPCOT officers.

-

-

-

... More
Up to 1.50 m to 4.50 m below GL

50.1

-

-

... More
Up to 1.5 m Below GL

22.52

-

-

... More
0-1.00 m Above GL

4.2

-

-

... More
1.00 to 4.50 m Above GL (Tie Beam)

30.91

-

-

... More
4.50 to 7.32 m For Column

11.83

-

-

... More
7.32 to 10.98 m for Column

31.59

-

-

... More
10.98 to 14.64 m Height for Column above GL (Up to 11.775m)

31.59

-

-

... More
14.64 to 18.30 m Height for column above GL

72.89

-

-

... More
0 to 1.00 m above floor slab

4.96

-

-

... More
1.00 to 4.50 m above floor slab

73.72

-

-

... More
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc., Complete complying with standard specification and as directed by SIPCOT Officers.

-

-

-

... More
0-3.30 m Below GL

-

-

-

... More
Plane Surface

125.64

-

-

... More
Square Surface

105.6

-

-

... More
Circular Surface

5.18

-

-

... More
3.30 to 4.30 m Below GL

-

-

-

... More
Plane Surface

75.12

-

-

... More
Square Surface

17.6

-

-

... More
Circular Surface

0.79

-

-

... More
4.30 to 5.30 m Below GL

-

-

-

... More
Plane Surface

13.84

-

-

... More
0-3.30 m above GL

-

-

-

... More
Square Column

105.6

-

-

... More
Circular Column

5.18

-

-

... More
3.30 to 4.30 Above GL

-

-

-

... More
Square Column

15.2

-

-

... More
Circular Column

0.75

-

-

... More
3.775 m to 4.225 m height from above GL

-

-

-

... More
Plane Surface

127.5

-

-

... More
4.225 to 4.30 m for column

-

-

-

... More
Circular Surface

0.37

-

-

... More
Square Surface

2.4

-

-

... More
4.30 to 5.30 m for Column

-

-

-

... More
Circular Surface

1.57

-

-

... More
Square Column

32

-

-

... More
5.30 to 6.30 m for Column

-

-

-

... More
Circular Column

1.57

-

-

... More
Square Column

32

-

-

... More
6.30 to 7.30 m for Column

-

-

-

... More
Circular Column

1.57

-

-

... More
Square Column

32

-

-

... More
7.30 to 7.775 m for Column

-

-

-

... More
Circular Column

0.75

-

-

... More
Square Column

15.2

-

-

... More
Tie beam at (TB) + 7.775 m Level (7.775 to 8.225m m Height) Plane Surface

127.5

-

-

... More
7.775 to 8.30 m for Column

-

-

-

... More
Circular Column

0.83

-

-

... More
Square Column

16.8

-

-

... More
8.30 to 9.30 m Height for Column

-

-

-

... More
Circular Column

1.57

-

-

... More
Square Column

32

-

-

... More
9.30 to 10.30 m Height for Column

-

-

-

... More
Circular Column

1.57

-

-

... More
Square Column

32

-

-

... More
10.30 to 11.30 m Height for Column

-

-

-

... More
Circular Column

1.57

-

-

... More
Square Column

32

-

-

... More
11.30 to 12.30 m Height for Column

-

-

-

... More
Circular Column

0.75

-

-

... More
Square Column

15.2

-

-

... More
Tie beam at (TB) + 11.775 m Level (11.775 to 12.225m m Height) - Plane Surface

127.5

-

-

... More
11.30 to 12.30 m Height for Column

-

-

-

... More
Circular Column

0.12

-

-

... More
Square Column

2.4

-

-

... More
12.30 to 13.30 m Height for Column

-

-

-

... More
Circular Column

1.57

-

-

... More
Square Column

32

-

-

... More
13.30 to 14.30 m Height for Column

-

-

-

... More
Circular Column

1.57

-

-

... More
Square Column

32

-

-

... More
14.30 to 15.30 m Height for Column

-

-

-

... More
Circular Column

1.49

-

-

... More
Square Column

22.4

-

-

... More
15.30 to 16.30 m Height for Column

-

-

-

... More
Circular Column

0.16

-

-

... More
Square Column

1.6

-

-

... More
Grid beam at (TB) + 15.10 m Level (15.10 to 16.00 m m Height)

-

-

-

... More
Curved Surface

805.6

-

-

... More
0-3.30m From Floor Slab (above G.L.)

-

-

-

... More
Curved Surface

298.63

-

-

... More
Square Column

52.8

-

-

... More
0-3.30m to 4.30 m Height

-

-

-

... More
Curved Surface

57.57

-

-

... More
Square Column

10.4

-

-

... More
Roof Slab at + 3.95 m level

-

-

-

... More
Curved Surface

36.43

-

-

... More
Plane Surface

133.31

-

-

... More
Painting the walls with two coats of cement paint over one coat of cement primer including preparation of surface curing, cost of primer etc. complete in all floors complying with standard specifications and as directed by SIPCOT officers. (The colour and shade of the cement paint shall be got approved by the Executive Engineer before use of work).

1420

-

-

... More
Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel bars high strength deformed bars like RTS bars etc.., conforming to FE 415 Grade for all RCC works including cost and conveyance of steel, binding wire to work site cost of fabrication ,labour charges for cleaning the rods , straightening , cutting, bending, tying grills, hoisting and placing the reinforcement in position before concreting , cost of binding wire , provision of space bars, cover blocks and all other incidental charges etc., complete complying with standard specification and as directed by SIPCOT officers.

531.02

-

-

... More
Construction of RCC Sprial stair case in RCC M30 design mix concrete of 1.80 m dia required height for approach to the roof of service reservoir with RCC hand rails as per type design of in cluding necessary earth work excavation in various classification of soils met with at the site of work for providing fountation concrete CC 1:4:8mix, RCC footing M30 Mix, GL Platform etc., including cost of steel reinforcement , fabrication charges, scoffholding, centring precastring, , cemeant painting the surfaces etc., complete complying with standard specification and as directed by SIPCOT officers. (Height is mentioned from GL to roof slab)

-

-

-

... More
Earthwork excavation and depositing on bank with initial lead and lift (a)in hard stiff clay,black cotton soil, hard red earth,shales, muram,gravel,stoney earth and earth mixed with 50% fair size boulders. etc., complete complying with standard specification and as directed by SIPCOT officers.

0.97

-

-

... More
Removing hard rock by wedging, chiselling & trimming to proper shape where blasting is prohibited with initial lead of 10 m and initial lift of 1 m etc., complete complying with standard specification and as directed by SIPCOT officers.

4.86

-

-

... More
Msand filling for foundation including the cost of sand,ramming and consolidationetc., complete complying with standard specification and as directed by SIPCOT officers.

0.49

-

-

... More
Plain Cement Concrete 1:4:8 (One Cement, Four M-sand and Eight hard broken stone jelly) using 40 mm ISS size hard broken granite stone jelly for foundation including dewatering wherever if found necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing including cost and conveyance of all materials to site etc., complete complying with standard specification and as directed by SIPCOT officers. for levelling course.

0.95

-

-

... More
Reinforced Cement concrete in 1:11/2:3 using 20mm ISS graded HBG metal including cost and conveyance of all materials to site and cost of cement at site including soft water, labour charges for form work, centering, mixing, transporting, laying and curing concrete, tools and plants and incidental charges excluding cost of steel etc., complete as per standard specification and as directed by SIPCOT officers.

-

-

-

... More
Column upto G.L.

0.84

-

-

... More
Column upto 4.50m from G.L.

0.39

-

-

... More
Column upto 4.50m - 7.32 m from G.L.

0.27

-

-

... More
Column upto 7.32m - 10.98m from G.L.

0.33

-

-

... More
Column upto 10.98m-14.64m from G.L.

0.33

-

-

... More
Column upto 14.64m-18.3m from G.L.

0.33

-

-

... More
Column upto 18.30 m-21.96 m from G.L.

0.33

-

-

... More
Landing Slab at top of S.R

0.1

-

-

... More
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc., Complete complying with standard specification and as directed by SIPCOT Officers.

-

-

-

... More
Rectangular portion below G.L.

0.9

-

-

... More
Column upto G.L.

0.94

-

-

... More
Landing slab @20 m

1.2

-

-

... More
Reinforced Cement concrete in 1:11/2:3 using 20mm ISS graded HBG metal including cost and conveyance of all materials to site and cost of cement at site including soft water, labour charges for form work, centering, mixing, transporting, laying and curing concrete, tools and plants and incidental charges excluding cost of steel etc., complete as per standard specification and as directed by SIPCOT officers. for steps

-

-

-

... More
Below G.L

8.88

-

-

... More
Reinforced Cement concrete in 1:11/2:3 using 20mm ISS graded HBG metal including cost and conveyance of all materials to site and cost of cement at site including soft water, labour charges for form work, centering, mixing, transporting, laying and curing concrete, tools and plants and incidental charges excluding cost of steel etc., complete as per standard specification and as directed by SIPCOT officers. for Jally work

1.66

-

-

... More
Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel bars high strength deformed bars like RTS bars etc.., conforming to FE 415 Grade for all RCC works including cost and conveyance of steel, binding wire to work site cost of fabrication ,labour charges for cleaning the rods , straightening , cutting, bending, tying grills, hoisting and placing the reinforcement in position before concreting , cost of binding wire , provision of space bars, cover blocks and all other incidental charges etc., complete complying with standard specification and as directed by SIPCOT officers.

14.82

-

-

... More
Charges for mould for casting steps etc., complete complying with standard specification and as directed by SIPCOT officers.

80

-

-

... More
Charges for mould for casting handrails posts etc., complete complying with standard specification and as directed by SIPCOT officers.

40

-

-

... More
Charges for mould for casting jollywork etc., complete complying with standard specification and as directed by SIPCOT officers.

40

-

-

... More
Providing scafolding for a length of 4m wide etc., complete complying with standard specification and as directed by SIPCOT officers.

1

-

-

... More
Lifting the steps and jolly works by means of pulley block and structing in position including hire charge for pulley block. etc., complete complying with standard specification and as directed by SIPCOT officers.

1

-

-

... More
Provision for fixing the saaircase with columns at brace level with MS clamps (or) with RCC beams. etc., complete complying with standard specification and as directed by SIPCOT officers.

1

-

-

... More
Providing M.S Grill gate at roof level woth lock etc., complete complying with standard specification and as directed by SIPCOT officers.

1

-

-

... More
Provision for finishing works etc., complete complying with standard specification and as directed by SIPCOT officers.

1

-

-

... More
Refilling the foundation with excavated earth (other than sand) including watering, ramming, consolidating etc., complete complying with standard specification and as directed by SIPCOT officers.

3.55

-

-

... More
Providing and fixing RCC inside access ladder of approved pattern and design in RCC 1:11/2:3 (One cement and one and half sand and three HBG stone of 20mm size ISS gauge) 0.40m width, 0.10m thickness, 0.12m breadth for side post, 0.05m thickness 0.12m breadth for steps with suitable inclination including cost of cement, reinforcement centering, finishing, curing etc., complete complying with standard specification and as directed by SIPCOT officers.

1

-

-

... More
Providing RCC ventilating arrangements etc., complete complying with standard specification and as directed by SIPCOT officers.

3

-

-

... More
Supplying and fixing in position of cut stone of size 0.3m x 0.3m x 0.15m at site in CM 1:3(One part cement and three part sand) at bottom of inlet pipe inside the Sump the suitable size etc., complete complying with standard specification and as directed by SIPCOT officers.

1

-

-

... More
Supply, delivery and fixing in position of 0.60x0.60 m C.I manhole frame and cover heavy duty approved patten at the roof slab and as directed . the manhole frame and cover should of light etc., complete complying with standard specification and as directed by SIPCOT officers.

3

-

-

... More
Labour charges for Painting Sipcot Emblem in accordance with the size and specifications as approved by the Board on the Service Reservoirs including cost of all consumables , one coat of base paint, scaffolding charges including painting NRDWP logo on the Service Reservoir etc., complete complying with standard specification and as directed by SIPCOT officers.

9

-

-

... More
Refilling the sides of foundation with excavated earth (other than sand) in layers of 15cm thick,watered well rammed and consolidated etc. complete complying with standard specification removing and spreading the surplus earth at the places shown etc., complete complying with standard specification and as directed by SIPCOT officers.

-

-

-

... More
As per item 2 a+2 b+ 2c+2d (188.642+85.460+85.460+51.276)=870.378m³. Less item no : 2. ( D/F sand filling quantity=-15m³). 3.(D/F P.C.C 1:4:8 quantity=14.18m³) 4.(D/F column R.C.C quantity up to GL=50.097+22.521=72.618m³) Total (870.378-15-14.18-72.618=768.58) add Extra 0.50 =769m³

769

-

-

... More
Parapet Wall Over roof slab for rain water harvesting arrangement

-

-

-

... More
Brick Work in CM 1:6 (One cement and Six sand)using country bicks of size 8.75" x 4.25" x 2" including for parapet wall alround roof slab etc., complete complying with standard specification and as directed by SIPCOT officers.

0.5

-

-

... More
Plastering in CM 1:5 (One cement and five sand) - 12mm thick alround papapet over roof slab icluding finishing curing etc., complete complying with standard specification and as directed by SIPCOT officers.

13.82

-

-

... More
Plastering in CM 1:3 (One cement and three sand) - over roof slab of reservoir with proper gradient of 1/50 for drain the rain water at the center of roof slab by cnnecting the rain water harvesting pipes with over flow pipe as per type design etc., complete complying with standard specification and as directed by SIPCOT officers.

149.36

-

-

... More
Painting the walls with two coats of cement paint over one coat of cement primer including preparation of surface curing, cost of primer etc. complete in all floors complying with standard specifications and as directed by SIPCOT officers. (The colour and shade of the cement paint shall be got approved by the Executive Engineer before use of work).

9.48

-

-

... More
Supply and fixing of pvc gratings of size 20x20cm for fixing in the roof of the reservoir. etc., complete complying with standard specification and as directed by SIPCOT officers.

1

-

-

... More
RECHARGE/SOAKOIT FOR RAIN WATER HARVESTING FOR RESERVOIR WITH FLAT ROOF.

-

-

-

... More
Earth work excavation and depositing on bank with initial lead of 10M and initial lift of 2M for Hard Stiff clay, Stiff black cotton,hard red earth, shales, murram, gravel, stoney earth and earth mixed with small sized boulders and hard gravely soil etc., complete complying with standard specification and as directed by SIPCOT officers.

8.82

-

-

... More
Brick work in CM 1:6 (One cement and six sand) using country bricks of size 8.75" x4.25"x2" including curing etc., complete complying with standard specification and as directed by SIPCOT officers.

1.45

-

-

... More
Supply,delivery and filling of M sand for the recharge piot s per type design. etc., complete complying with standard specification and as directed by SIPCOT officers.

0.47

-

-

... More
Supply,delivery and filling of 20 mm size brick bats as per type design. etc., complete complying with standard specification and as directed by SIPCOT officers.

1.88

-

-

... More
Supply,deliery ad filling of 40mm size brick batsas per type design. etc., complete complying with standard specification and as directed by SIPCOT officers.

3.46

-

-

... More
Supply,deliery and fixing of splash pad of size 500 x 500 x 50mm at the over flow junction point with recharge pit. etc., complete complying with standard specification and as directed by SIPCOT officers.

1

-

-

... More
Cost of pipes - 110mm OD UPVC - 4 Ksc etc., complete complying with standard specification and as directed by SIPCOT officers.

18

-

-

... More
Fixing pvc pipes with clamps etc., complete complying with standard specification and as directed by SIPCOT officers.

1

-

-

... More
Supply Top bases Lightning Arrester – SIRUS Supply of ESE lightning air terminal with the below technical parameters. • Stainless Steel material (304 L) – suitable for corrosive environments • Delta T = 60 micro seconds • HIZAL lab tested as per NF C 17-102 (2011) standard • Tested for 204 KA peak impulse current • Ipeak-avg = 102 KA • Protection radius = 107 mtrs (Level 4 / Standard) Model: SIRUS,Supply of 17.2mm Dia Copper Bonded Rod 3 Mtrs Long with SS Unit , Bolt and 50Kg EFC,MOUNTING STRUCTURE Standard Mounting Structure of 6 mtrs height with GI pipe and base plate suitable for roof mounting,Control Analogue Type,Supply of 25 x3 Copper Strip,Installation of ESE Lightning Arrester 1) Installation of Mounting Structure 2) Installation of Lightning Rod 3) Laying of Down conductor Installation of Earth Electrodes 4) Installation of earth electrode,Scaffolding Charges

1

-

-

... More
Special & Advance Features Can be View Water Level using Inbuilt Application from Android Mobile and Computers ("I -Talk") Easy to verify Water Flow & Pervious Date/Month/Year Datas Can be checkedUsed Solar Panel Monocrystalline & No EB Required.LED Display Unit (Hibeam Red Color LED Light).Inbuilt Buffer Alarm for Water High and Low.Inbuilt Lithium Battery Backup For 2 Days (3 Years Warranty).CallBack for User when Water is at High or Low level.100% Message to user for Waterlevel 70% & 20%,Scaffolding Charges. etc., complete complying with standard specification and as directed by SIPCOT officers.

1

-

-

... More
Supply and fixing of precast RCC handrails of 0.91 m height in M 20 concrete over the top of the roof slab of approved pattern and resign including the cost of concrete mix, Reinforecment, Centering and labour charges etc complete Opening of stair case. etc., complete complying with standard specification and as directed by SIPCOT officers.

45

-

-

... More
Provision for Air vent pipes inner dia 0.40 m in M 30 with RCC rods and mould including supply and Delivery of weld mesh 10 cm X 10 cM in 10 Kauge Sq with cost of labour for lifting, fixing etc. complete and leveling site etc., complete complying with standard specification and as directed by SIPCOT officers.

4

-

-

... More
Sub Total of Total Amount in Column BA (ie. Qty x Unit Rate)

1

-

-

... More
Added GST of 18%

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.