State Industries Promotion Corporation Of Tamil Nadu Limited Tender

Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.

State Industries Promotion Corporation Of Tamil Nadu Limited - SIPCOT Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date3 Jul 2024
Closing Date18 Jul 2024
Tender Amount₹ 15,14,00,000 
Notes
Download

Costs

Summary

Construction Of Dining Hall Building

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
2 to 3m depth

700

-

-

... More
Supplying and filling in foundation, basement, etc with filling stone dust in layers of not more than 15 cm thick well watered, rammed and consolidated etc., complete complying with standard specification.and as directed by SIPCOT officers.

675

-

-

... More
Supplying and filling in foundation, basement, etc with filling Carted earth in layers of not more than 15 cm thick well watered, rammed and consolidated etc., complete complying with standard specification.and as directed by SIPCOT officers.

1970

-

-

... More
Refilling in foundation and basement and other similar works with Excavated earth in layers of 150mm thick well watered rammed and consolidated complying with relevant standard specification etc., complete complying with standard specification.and as directed by SIPCOT officers.

1250

-

-

... More
Plain Cement Concrete 1:4:8 (One of cement, four of Crushed stone sand and eight of hard broken stone jelly) for foundation using 40mm gauge hard broken stone jelly inclusive of shoring, strutting and bailing out water wherever necessary ramming, curing etc., complete in all respects complying with standard specification.and as directed by SIPCOT officers.

185

-

-

... More
Flooring with a bed of CC 1:5:10 (One of cement, four of Crushed stone sand and Ten of hard broken stone jelly) using 40mm size HBG Jelly and top left to receive the floor finish curing etc., complete in all respects complying with relevant etc., complete complying with standard specification.and as directed by SIPCOT officers.

275

-

-

... More
Providing and laying in position, Standardised Concrete Mix M-35 Grade in a accordance with IS:456-2000 using 20mm and down graded hard broken granite stone jelly for the all RCC items of works with minium cement content of 425 Kg/m3 and maximum water cement ratio of 0.45, including admixture (plasticiser/super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 cum) 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum) 5156 Kg of 10-12mm machine crushed stone jelly and with about (4.79 cum) 7670Kg of sand (for making 10 cum) but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing etc., and providing fixtures like fan clamps in the RCC floor/roof slabs wherever necessary without claiming extra etc., complete complying with relevent standard specification and as directed by the SIPCOT officers. The coarse and fine aggregates to be used should comply with requirements of IS standards. (No separate payment will be made by SIPCOT for the excess usage of materials)

-

-

-

... More
Foundation and Basement

530

-

-

... More
In Ground floor

965

-

-

... More
In First floor

200

-

-

... More
In Second floor

50

-

-

... More
Supplying, fabricating and placing in position of Ribbed Tor Steels for reinforcement for all floors including cost of binding wire, bending, tying etc., complete complying with standard specification.and as directed by SIPCOT officers.

2450

-

-

... More
Providing Form work and centering for reinforced cement concrete works including supports and strutting up to 3.30m height for plane surfaces as detailed below with all cross bracings using mild steel sheets of size 90cmx60cm and MS 10 gauge stiffened with welded mild steel angles of size 25mmx25mmx3mm for boarding laid over silver oak or country wood joists of size 10cmx6.5cm spaced at about 90cm centre to centre supported by caurina props 10cm to 13cm dia spaced at 75cm intervals and removing the same after a specified period without damaging the RCC works etc., complete complying with standard specification.and as directed by SIPCOT officers.

-

-

-

... More
For Column footing , Grade beam, Plinth beam Below plinth

1700

-

-

... More
Plain surfaces

5130

-

-

... More
Square & Rectangular Column

1520

-

-

... More
Vertical Walls

100

-

-

... More
Brick work in Cement Mortar 1:5 (One Cement and Five M Sand) using best quality of II Class Ground Moulded Chamber Burnt Brick of size 9" x 43/8" x 23/4"for foundation and basement including curing, etc., complete complying with standard specification.and as directed by SIPCOT officers.

-

-

-

... More
Foundation and Basement

300

-

-

... More
Brick work in cm 1:6 (One of cement and Six of crushed stone sand) using Ground moulded Kiln burnt chamber bricks of size Bricks of size 9" x 43/8" x 23/4" in super structure including dewatering wherever necessary proper setting, curing etc., complete complying with standard specification.and as directed by SIPCOT officers.

-

-

-

... More
Ground floor

295

-

-

... More
First floor

190

-

-

... More
Second Floor

65

-

-

... More
Brick partition walls of 11.50cm thickness using best quality II Class Table Moulded Chamber Burnt Bricks of size 9" x 4-3/8" x 2-3/4" in Cement Mortar 1:3 (One Cement and Three Sand) using hoop iron reinforcement if found necessary including curing etc., complete complying with standard specification.and as directed by SIPCOT officers. (Hoop iron reinforcement will be measured and paid for separately)

-

-

-

... More
Ground floor

110

-

-

... More
First floor

105

-

-

... More
Second Floor

60

-

-

... More
Plastering with Cement Mortar 1:5 (One cement and Five Plastering sand), 12 mm thick in all floors including curing etc., complete complying with standard specification.and as directed by SIPCOT officers.

7860

-

-

... More
Ceiling Plastering with CM 1:3 (One of cement and three of crushed stone sand) 10mm thick finished with neat cement including providing band cornice, ceiling cornice, curing scaffolding etc., complete complying with standard specification.and as directed by SIPCOT officers.

3920

-

-

... More
Plastering with CM 1:3 (One of cement and three of crushed stone sand) 12mm thick finished with water proofing compound cement etc., complete complying with standard specification.and as directed by SIPCOT officers.

110

-

-

... More
Weathering course with brici jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime ratio 32:12.5 ,well watering consolidated with wooden beaters etc., complete complying with standard specification.and as directed by SIPCOT officers.

18

-

-

... More
Suppling and laying of Double Charged Vitrified Tiles 800 x 800 x 8mm in CM 1:3 (One of cement and three of M sand) 10mm thick including fixing in position, cutting the tiles to the required size wherever necessary, pointing the joints with grout (Tile joint filler) curing, finishing etc., complete complying with standard specification.and as directed by SIPCOT officers.

5100

-

-

... More
Supplying and laying of granite Slab 18-20mm thick . in CM 1:3, (One of cement and three of M sand) 20mm thick including fixing in position, cutting to the required size wherever necessary, pointing the joints with grout (Tile joint filler) curing, finishing etc., complete complying with standard specification.and as directed by SIPCOT officers.

45

-

-

... More
Providing Double Nosing for wash basin and service counter granite slab area including cost of all labour charges etc., complete complying with standard specification.and as directed by SIPCOT officers.

105

-

-

... More
Supplying and fixing of colour ceramic tiles (Anti skid) of size 300 x 30 x 6mm without corrugated design for flooring and other similar works (best approved quality colour and shade shall be got approved from SIPCOT Officer before using) over cement 1:3 (one cement and three of M sand) 20mm thick including fixing in position, cutting the tiles to the required size wherever necessary, pointing the joints with grout (Tile joint filler) curing, finishing etc., complete complying with standard specification.and as directed by SIPCOT officers.

280

-

-

... More
Dadooing walls with best approved quality, white / colour glazed tiles of size 150 x 150 x 6 mm set in Cement Mortar 1:2 (One Cement and Two M sand) 10mm thick and pointing the joints with white cement mixed with colouring pigments at the rate of 0.40 Kg. / sq.m. neatly in all floors, curing, etc., complete complying with standard specification.and as directed by SIPCOT officers.

335

-

-

... More
Supplying and laying of Eurocon tiles of size 300 x 300 x 18-20mm in CM 1:3 , (One Cement and three M sand) 20mm thick etc., complete complying with standard specification.and as directed by SIPCOT officers.

420

-

-

... More
Paving the Top of roof with Solar refelective ceramic tiles of size 305 x 305 x 7mm thick of approved quality and colour laid with base concrete. 1:2:4 wise -6-10mm aggregate in Cement mortar 1:3 (One cement and three crushed stone sand) 12mm thick and pointed with tile grout (Nitotile Grout or equivalent) and cement in the ratio of 1:3 for joint, curing etc., complete complying with standard specification.and as directed by SIPCOT officers. (The make and brand of the tiles should be got approved by the SIPCOT Officer before use on works)

430

-

-

... More
Painting two coats of newly plastered wall surface with ready mixed plastic Interior emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification.and as directed by SIPCOT officers.

7620

-

-

... More
Painting two coats of newly plastered wall surface with ready mixed Exterior emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification.and as directed by SIPCOT officers.

4160

-

-

... More
Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm diaStainless Steel pipe post of 1.00mm thick as vertical at900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete. The rate is inclusive of the charges for cutting, bending, welding,grinding, polishing, conveyance, electrical charges, etc., complete complying with standard specification.and as directed by SIPCOT officers.

55

-

-

... More
Supplying and fixing of half turn C.P Long body Tap of 15mm dia of Best quality including cost of half turn CP tap with required specials and labour for fixing etc., complete complying with standard specification.and as directed by SIPCOT officers. (The quality and brand should be got approved from SIPCOT Officer before use).

17

-

-

... More
Supplying and fixing of 110mm dia PVC SWR pipe with ISI mark confirming to IS 13952:1992 Type 'A' for Rainwater Down fall pipe with relevant specials such as gratings, shoes, bends, offsets confirming to IS 14735 including jointing with seal ring confirming to IS 5382 with leaving a gap about 10mm to allow thermal expansion with necessary clamps, teak wood plugs etc., of approved quality and including fixing CI gratings at the junction of parapet and floor or roof slab etc., including finishing etc., complete complying with standard specification.and as directed by SIPCOT officers.

100

-

-

... More
Supplying and fixing of 200mm dia PVC SWR pipe with ISI mark confirming to IS 13952:1992 Type 'A' for Rainwater Down fall pipe with relevant specials such as gratings, shoes, bends, offsets confirming to IS 14735 including jointing with seal ring confirming to IS 5382 with leaving a gap about 10mm to allow thermal expansion with necessary clamps, teak wood plugs etc., of approved quality and including fixing CI gratings at the junction of parapet and floor or roof slab etc., including finishing etc., complete complying with standard specification.and as directed by SIPCOT officers.

90

-

-

... More
Providing Solid PVC Door Shutters using 19 Gauge 19mm MS square tubes for styles and outer frames. 15mm MS square tubes for top, lock and bottom rails. The steel tubes shall be covered with 5mm thick solid PVC Sheets. Shutter using 5mm thick solid PVC Sheets for panelling shall rigidly fixed in position including necessary furniture and fittings. The over all size of styles shall be 50mm x 30mm. The over all size of top rail, lock rail and bottom rail shall be 75mm x 30mm. The over all size of frames shall be 50mm x 45mm with suitable rabate for housing the shutter with frame (etc., complete complying with standard specification.and as directed by SIPCOT officers.

27

-

-

... More
Supplying and fixing of Teak Wood wrought and put up for frames of doors, windows, ventilators, cupboard and any other similar joinery works with necessary plugs, rebates for shutters, plaster grooves on all faces etc. , including labour charges for fixing hold fasts. etc., complete complying with relevant standard specifications and as directed by SIPCOT officers.

-

-

-

... More
T.W.Scantling

-

-

-

... More
Below 2 m

0.34

-

-

... More
Over 2m & below 3m length

1.25

-

-

... More
Supplying and fixing mild steel grills for windows, ventilators, etc., including priming coat etc., complete complying with standard specification.and as directed by SIPCOT officers.

11860

-

-

... More
Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat etc., complete complying with standard specification.and as directed by SIPCOT officers.

310

-

-

... More
Painting new wood work with 2 finshing coats of synthetic enamel ready mixed paintr of approved quality. And colour over one coat priming coat in all floors inculding cost of primer etc., complete complying with standard specification.and as directed by SIPCOT officers. ( the make quality and colour of paint should be got approved by there SIPCOT Officer before use on works)

180

-

-

... More
Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Window of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the SIPCOT officers before use on work etc., complete complying with standard specification.and as directed by SIPCOT officers.

205

-

-

... More
Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilator of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile 60*78mm are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the SIPCOT officers before use on work.

51

-

-

... More
Providing pre-constructional Antitermite treatment including cost of chemicals labour as per standard specifications for preparing the area for treatment by spraying chemicals and other incidental charges etc.. complete. The rates should be for curing antitermite treatment from the plinth beam and brick masonry with super structure in contact with the back fill earth and at the junction of the walls. The top surface of filled earth for flooring and the soil along with the perimeter of the building by making holes with the crow bar and poured 5% termicide. “Chloripyrifos” and spraying the same termicide solution on the wooden frames and treating the other periphery of buildings etc., complete in all respects as per IS 6313 (part II)/ 1981 etc., complete complying with standard specification.and as directed by SIPCOT officers.

2910

-

-

... More
Applying one coat of Anti-corrosive treatment for steel fabrication (RCC works) including cost of chemicals, labour as per standard specifications for preparing the area for treatment by brushing chemicals and other incidental charges etc., complete complying with standard specification.and as directed by SIPCOT officers.

245

-

-

... More
Supplying and fixing of Indian Water Closet white glazed (oriya type) of size 580 mm X 440 mm of approved make with ISI mark (to be got approved from SIPCOT officers before use) with PVC SWR grade 'P' or 'S' trap, including concrete filling the sunk portion with brick jelly lime concrete proportion of brick jelly to lime being 32:12½ by volume (32 cft of 20mm gauge brick jelly and 12 ½ cft of slaked lime) (No sand) and top 75mm thick brick jelly concrete in CC 1:8:16 (one of cement, eight of sand and sixteen of broken brick jelly) using 40mm size brick jelly including plastering the sides of sunk portion in Cm 1:3 (one of cement and three of sand) 12mm thick mixed with water proofing compound at 2Kg / m2 and top left rough to receive the floor plastering but including antisyphonage connection, one coat of bitumen for the sides, bottom and curing etc., complete complying with standard specification.and as directed by SIPCOT officers.

9

-

-

... More
Supplying and fixing EWC superior variety (white) 500mm with PVC SWR grade 'P' or 'S' trap including cost and fixing of double flapped coloured plastic sheet cover PVC flushing cistern in appropriate level as directed by the departmental officers at a maximum level of 5’6” and of approved brand of 10litres capacity including fittings such as CI brackets. PVC connection GM wheel valve, Hex nipple, etc., complete (The Quality and brand of EWC and plastic cover shall be got approved from the SIPCOT officers before fixing) etc., complete complying with standard specification.and as directed by SIPCOT officers.

8

-

-

... More
Supply & Fixing of Bevelled edge mirror of approved quality and brand of size 500x400x5.5mm shelf type mounted in the PVC / Fibre Glass framed with necessary hard board backing including labour for fixing in position etc., complete complying with standard specification.and as directed by SIPCOT officers.

12

-

-

... More
Supplying and fixing of PVC Nahani Trap not less than 75mm 4 way / 2 way (Superior variety) having minimum of water seal of 50mm confirm to relevant I.S. specifications with its latest amendments including resting on the bed of brick jelly concrete 1:5:10 (One of cement, five of sand and ten of 40 mm gauge brick jelly) etc., complete as directed by the SIPCOT officers. (The PVC Nahani Trap should be got approved from the SIPCOT officers before use)

17

-

-

... More
Supply and fixing of White Lipped Mouth Procelain Flat Back Urinal with all accessories such as 32mm dia bell mouth PVC connection,15mm dia GM wheel valve,15mm dia 'B' Class GI waste water pipe, 15mm dia Nylonconnection, 15mm dia brass Nipple etc., complete complying with standard specification.and as directed by SIPCOT officers.

14

-

-

... More
Providing Rain water harvesting pit of 1m dia and 600mm depth and filling the pit with 40mm stone jelly to a depth of 300mm from the top of the augering portion and filling with filling sand to a depth of 300mm over the stone jelly and covered with the pre-cast RCC perforated slab of 40mm thick excluding the cost and fabrication of reinforcement grills but including precasting, moulding, curing, finishing and fixing in position etc., all complete and as directed by the SIPCOT officers.

10

-

-

... More
Augering 30cm dia bore hole in all soils and sub soils required depth for providing rain water harvesting from the centre of the rain water harvesting pit already excavated and filling the augering portion with 40mm size stone jelly etc., all complete and as directed by the SIPCOT officers.

30

-

-

... More
Providing Rain water Harvesting Pit by Earth work excavation in Circular shape of 90cm dia at 60cm depth the pit is encased with well ring of 90cm etc., all complete and as directed by the SIPCOT officers.

10

-

-

... More
Supplying and fixing of porcelain Oval shape Wash hand basin superior variety of size 560x450mm with all accessories such as powder coated cast iron brackets, 32mm dia C.P. waste coupling, Rubber plug and aluminium chain, 32mm dia 'B' class G.I. / PVC waste pipe, Angle Valve, 15mm dia Nylon connection inculding necessary, specials etc., all complete and as directed by the SIPCOT officers.

12

-

-

... More
Supplying and fixing of T.W DOOR SHUTTER TWO LEAVES (3000 X 2400 mm ) with Brass Fittings and Vision Glass etc., all complete and as directed by the SIPCOT officers.

20

-

-

... More
Supply and Fixing of T.W DOOR SHUTTER TWO LEAVES(1800 X 2400 mm With Brass Filltings and Vision Glass etc., complete complying with relevant standard specifications and as directed by SIPCOT officers.

27

-

-

... More
Supply and Fixing MS Door double leaf of size 1800x2400 mm with outer frame and shutter frame in MS angle etc., complete complying with relevant standard specifications and as directed by SIPCOT officers.

35

-

-

... More
Supply and Fixing Solid core Flush door shutter size 900x2400 ( Single leaf) with teakply on both side with teakwood lipping alround 35mm thick etc., complete complying with relevant standard specifications and as directed by SIPCOT officers.

15

-

-

... More
Supply and fixing of SS Sink of size 1200mm x550x180mm for Pantry and dinning area in Ground floor etc., complete complying with relevant standard specifications and as directed by SIPCOT officers.

48

-

-

... More
Manufacturing, Supplying and fixng of precast reinforced cement concrete slab of 50mm thick 1:2:4 (One of cement, two crushed stone sand and four aggregates ) using 10-12mm HBGS jelly including cost of reinforcement steel in posiyion but including cost of all materials, moulding, curing, transportion, laying, pointing etc., for approach road, pavement slab and other similar works etc., complete as per the relevant standard specifications and as directed by the SIPCOT officers.

85

-

-

... More
Manufacturing, Supplying and fixng of precast Plain cement concrete slab of 50mm thick 1:2:4 (One of cement, two crushed stone sand and four aggregates ) using 10-12mm HBGS jelly including cost of all materials, moulding, curing, transportion, laying, pointing etc., for approach road, pavement slab and other similar works etc., complete as per the relevant standard specifications and as directed by the SIPCOT officers.

150

-

-

... More
Supplying, laying, fixing and jointing the following PVC pipes as per ASTM D - 1785 of schedule 40 of wall thickness not less than the specified in IS 4985 suitable for plumbing by threading of wall thickness including the cost of suitable PVC/GI specials /GM specials like Elbow, Tee reducers, Plug, union, bend, coupler, nipple/ GM gate valve, check and wheel valve etc., wherever required above the ground level including the cost of teflon tape, special clamps, nails, etc., fixing on wall to the proper gradient and alignment and redoing the chipped of masonry etc., as directed by the departmental officers.

-

-

-

... More
32mm dia ASTM D schedule 40 threaded PVC pipe with necessary PVC/GI specials

20

-

-

... More
25mm dia ASTM D schedule 40 threaded PVC pipe with necessary PVC/GI specials

180

-

-

... More
20mm dia ASTM D schedule 40 threaded PVC pipe with necessary PVC/GI specials

100

-

-

... More
Supplying and fixing the following dia PVC (SWR) pipe with ISI mark confirming to IS 13952:1992- type 'B' for soil line with relevant specials confirming to IS 14735 including jointing with seal ring confirming to IS 5382 with leaving a gap about 10mm to allow thermal expansion, fixing the pipes into walls with necessary wooden plug, screws, holding wherever necessary and making good of the dismantled portion with necessary connections to sanitary fittings etc., complete complying with relevant standard specifications and as directed by SIPCOT officers.

-

-

-

... More
110mm dia PVC SWR pipe including all required PVC specials etc., all complete.,

65

-

-

... More
75mm dia PVC SWR pipe including all required PVC specials etc., all complete.,

250

-

-

... More
Supplying and fixing of two way bib cock with Health faucet approved quality with ISI mark ( Health faucet shall be got approved from the SIPCOT Officers before use.) including all accessories etc., complete complying with relevant standard specifications and as directed by SIPCOT officers.

17

-

-

... More
Providing construction of Insepction chamber size 0.60 x 0.60 x 0.90m including E.W AND REFILLING, C.C (1:5:10) USING 40mm brick jelly metal,B.W IN C.M (1:5), PLASTERING IN C.M (1:3) 12 mmT.K, R.C.C (1:2:4) PETTY WORKS, (50mm T.K PCC SLAB) in all etc., complete complying with relevant standard specifications and as directed by SIPCOT officers.

10

-

-

... More
Supplying and fixing 150mm x 100mm size stone ware Gully trap with iron gratings over a bed of 150mm thick brick jelly concrete in CC 1:3:16 (one of cement, eight of sand and sixteen of broken brick jelly) using 40mm size brick jelly and brick masonry wall 114 mm thick using chamber burnt bricks of size 9”x4-1/2”x3” (23x11.4x7.5cm) in CM 1:5 (One of cement and five of sand) plastered with CM 1:3 (One of cement and three of sand) 12mm thick etc., complete complying with relevant standard specifications and as directed by SIPCOT officers.

25

-

-

... More
Supply, Fabrication & Erection of Steel Structural Truss, Purlin, base plate, top plate, Joining plate with necessary fasteners with full finishing as per the drawing etc., complete complying with relevant standard specifications and as directed by SIPCOT officers.

149760

-

-

... More
Supply and laying of Puf panel- Panels shall be madeout with 0.35mm thick prepainted GI sheet (PCGI) at outer side and roof shall be done with 50mm sandwich puf (POLYurethane Foam ) panel having density of 40kg per cum (+2kgs).The p[anels joint together by tongue and groove method and placed colour sky blue/ half white etc., complete complying with relevant standard specifications and as directed by SIPCOT officers.

2880

-

-

... More
POST TENSIONING WORKS : Design and Execution, of post tensioning works, including, decoiling the strands, cutting to the required lengths, supplying laying of HT strands sheathing (GI corrugated ducts 0.3mm thick) jointing with couplers, and inserting the strands, profiling, fixing live end anchorages, including the supply of stressing anchorages, suitable for 5-5 & 5-4 tendons, grout vents, making dead end anchorages, including flowering the strands, fixing tendon support bars, supervising the fixing of anti-bursting reinforcement, stressing the cables, end trimming, grouting the cables, with cement slurry, mixed with admixtures , with required tools, plants, and machineries, and consumables etc. (shuttering, concreting & reinforcement steel, shall be paid under respective items) at all heights including all leads, lifts, coordination, with the post-tensioning agency, preparation of drawings, obtaining approval from the Employer / Architect etc. Rate to include providing water, power, cement and admixture for grouting, packing of sheathing and anchorages blockings, filling of recess pockets after stressing using grouts(cement slurry mixed with approved admixtures) including providing access to post tensioning at all heights including all leads, lifts etc., all complete and as approved and as directed by the Employer /Architect but excluding shuttering, concreting & reinforcement steel which shall be payable under respective items separately. PWD Approved PT Agency Ucon Structural System pvt Ltd. SIPCOT, Vallam Vadakal: Ground Floor Roof (Canteen Block) Eligibility criteria for PT Vendor 1. The PT Agency should have minimum 10 (Ten) years experience in post – tensioning works. 2. The PT Agency may be either a registered partnership firm or a company limited by shares having experience in similar construction and the design Engineer should have minimum 10 years of design experience. 3. The PT Vendor Should Posses Design Experience & Execution Experience More than 10 Years in India. 4. The PT Systems (Anchorages) should be in use for more than 10 years and it should be validated by systems performance test conducted in a registered laboratory etc., complete complying with relevant standard specifications and as directed by SIPCOT officers.

19

-

-

... More
Supplying and fixing of SFRC manhole cover of approved quality and brand of size 0.6mx0.6m as per standard specifications including cost of material, labour charges for fixing etc., complete complying with relevant standard specifications and as directed by SIPCOT officers.

2

-

-

... More
Providing and fixing of Aluminium Dye cast letters of approved size and colour. The colour treatment process is achieved with MRF colour coat and then the processed coloured layer is set into the kiln for the heat treatment process in the following sizeand as directed by SIPCOT officers.

-

-

-

... More
Aluminium Dye Cast letters 9" Size

28

-

-

... More
Aluminium Dye Cast letters 6" Size

11

-

-

... More
Internal electrical Arrangements

-

-

-

... More
MAIN PANELS-Design, Supply, fabrication, erection, testing and commissioning of - MV Panel suitable for 415Volts 3Phase 4wire system, fabricated from 14 & 16SWG CRCA sheet steel, 40 X 40 X 6 MS Angle panel frame, 800A TPN Aluminium bus bar Size Ph: 1R x 100 x 10mm, NL: 1R x 100 x 6mm, Earth 1R x 25 x 3mm and interconnections with black painted and SMC Bus bar supports. Bus bar supports, Current density of the Bus bars shall not exceed, single fronted, free standing, front hinged, rear removable, extendable on both sides, dust & vermin proof, cubicle type, floor mounted, undrilled gland plates at bottom, complete with internal wiring, ferrules, name plates, painting etc., comprising of the following.

1

-

-

... More
EB Incomer comprising of :1 No. 320 Amps 4P, 50KA, Mechanical draw out type Air Circuit Breaker trip - release for O/L, S/C, E/F protection and Mechanical Interlock for EB. DG Incomer -1 No. 630 Amps 36kA 4P, L&T MCCB with RHOM & Spreader and Mechanical Interlock for DG. Solar Incomer-1 Nos. of 160 Amps 4 Pole 36kA µP based MCCB with door interlock and all other accessories. Instrumental compartment. Combined digital meter, Maximum demand controller , Ammeter, Voltmeter, Instantaneous over current, earthfault relay (3 O/C+ 1 E/F), Necessary CTs, PTs, control MPCB/MCB/ ELCB/RCBOs, RYB Indication lamps and “ON/OFF/Trip/Rest" indicating lamp, voltage surge protection with emergency lockable push buttons and also refer the specification and SLD.OUTGOINGS. 400A 4P MCCB 36KA - 1 Nos, 250A 4P MCCB 36KA - 3 Nos, 200A 4P MCCB 36KA - 1 Nos, 125A 4P MCCB 36KA - 1 Nos, 100A 4P MCCB 36KA - 3 Nos.With necessary aluminium busbars, interconnections, providing RYB phase indication lamps, surge protection devices with suitable fuses, Digital multi function meter with necessary CTs, control MCB/MPCB/RCBOs etc. at incoming feeder. Also providing ON,OFF & TRIP indication lamps at both incoming and outgoing feeders and all as per the relevent standards and SLD/ specification enclosed. All MCCBs should have two (spare) potential free contactor for monitoring ON, OFF & TRIP status of each through BMS and all as per the specification and drawings. Incoming feeder MFM should have the facility to monitor Harmonic THD and individual harmonic display+ Regular parameters like V, I, KVA, KVAR, KW, KWH, KVARh, PF, Freq, Max, AVG etc. All Outgoing Feeders in Main LT panel shall be with MFM monitoring V,I, KWH, KVARH, PF with RS 485 BMS integration. All the metres to be wired and terminated at common metre chamber / marshalling feeder of each panel section. The DG incoming feeders should have the facility for load shedding during the loads are connected to DG source. Accordingly it should be decided which DG should run / goes to shut off to cater the live demand load/ based on the load consumption and all the incoming breakers of DG should be logically controlled to meet the said requirement with necessary control relays and logic controls as required. Also please note that all the incoming feeders of Main LT panel should be both electrically and mechanically interlocked with each other

-

-

-

... More
630Amps 4P 36kA aluminium busbars:- All the neutral busbars shall have the same capacity of phase busbars. etc., complete complying with relevant standard specifications and as directed by SIPCOT officers.

-

-

-

... More
PDB - (7 segment DB)- 8 WAY- Supply and fixing of 7 segment8 way63A TPNMCB sheetsteeldistributionboard (Higherend)with metal/ acrylic doorcover flush type /surface type fitted with busbars and neutral links with single / three phase MCB outgoings and seperate 4 way provision for accomodating one no. 4 pole incoming MCB / Isolator and another seperate 4 way provision for accomodating one no. 4 pole ELCB / RCD (totally 8 ways in one segment) (3x 6 ways in each segment) and seperate provision for MCB / Isolators ( totally 18 nos.) for sub incomers in 3 segments with lable holder and provison for taking up cable for size not less than 35 sq.mm. withthe following in flush with wall with earth connection only.63A 4P MCB 10kA – 1No. as incomer.63A DP ELCB 30MA – 3 Nos. as outgoings.6Ato32ASPMCB - 24nos.With necessary tinned copper busbars, interconnections, separate earth bus, separate neutral bus for each phases. The board shall be powder coated type fixed with concealed system in wall/ fixed in column. The rate shall include necessary connected civil works like chipping, rough plastering etc. etc., complete complying with relevant standard specifications and as directed by SIPCOT officers.

8

-

-

... More
Supply and Laying of PVC armoured LTUG cable with suitable size HDPE pipe in atrench to be excavated at a depth of 0.75 metre andrefilling the earth to make good.All installation works should be as complete and as directed by Employer / Employer's representative. The rate includes necessary connected minor civil works if required and necessary supports as required at site. No extra payment will be made for the same. etc., complete complying with relevant standard specifications and as directed by SIPCOT officers.

-

-

-

... More
3.5Core 120 Sq.mm PVC armoured cable

150

-

-

... More
3.5Core 35 Sq.mm PVC armoured cable

200

-

-

... More
3.5Core 25 Sq.mm PVC armoured cable

150

-

-

... More
4Core 16 Sq.mm PVC armoured cable

50

-

-

... More
1 Core 6 Sq.mm PVC Copper flexible cable

300

-

-

... More
CABLES AND TERMINATIONS-Supply and termination of the following size cables with suitable glands (weather proof glands) with suitable size PVC boot and suitable crimping socket, gland earthing by using copper flexible and all other necessary accessories. (copper sockets for copper cables and Alu. Sockets for alum. Cable) etc., complete complying with relevant standard specifications and as directed by SIPCOT officers.

-

-

-

... More
3.5Core 120 Sq.mm PVC armoured cable

4

-

-

... More
3.5Core 35 Sq.mm PVC armoured cable

40

-

-

... More
4Core 16 Sq.mm PVC armoured cable

20

-

-

... More
1 Core 6 Sq.mm PVC Copper flexible cable

20

-

-

... More
EARTHING ,CABLE TRAYS AND MS ITEMS - Supply and installation of UL listed and CPRI tested copper bondedsteelelectrode of 25 mm dia. With a min. coating thickness of 250 microns andlength of 3 meters. 30kgs of earth enhancing compound needs to be considered to fill the 100mm augered hole surrounding to the electrode.65x10x300mm copper busbar to be exothermically welded to the electrode. All connection to the busbar shall be exothermically welded as per the drawing and should comply with IEEE 837 and UL approved .The rate shall include excavation of earth, filling with back fill compound, exothermic welding etc. Also the rate is inclusive of construction of 850mm x 850mm x 300 mm high brick wall chamber with cement mortor. The chamber shall be provided with 450mm x 450mm heavy duty RCC cover with frame and lockable facility. The Complete installation shall be as per the drawing and technical specifications. ( EB PANEL & DG All installation works should be as complete and as directed by Employer / Employer's representative.The rate includes necessary connected minor civil works if required and necessary supports as required at site. No extra payment will be made for the same. etc., complete complying with relevant standard specifications and as directed by SIPCOT officers.

4

-

-

... More
EARTHING ,CABLE TRAYS AND MS ITEMS -NEUTRAL EARTH Supply and installation of earth pipe electrode as per IS 3043 complete with 3 mtr long with 40mm dia 'B' class G.I. pipe and copper earth plate of size 600mm x 600mm x 3mm including 2 Runs of 50 x 10mm CU . flat upto test link from plate earth electrode, watering funnel and necessary bolt, nut and double washer. Including 750mm x 750mm x 3mtr long excavation and construction of 850mm x 850mm x 300 mm high brick wall chamber with cement mortor. The chamber shall be provided with 450mm x 450mm heavy duty RCC cover with frame and lockable facility. The plate electrode shall be filled with 50Kgs of earth enhancing compound(PROCEM) tested as per IEC 62561-7 as required as full depth. The Cover shall be heavy duty to suit heavy vehicle movements - The Complete installation shall be as per the drawing and technical specifications. ( EB PANEL & DG All installation works should be as complete and as directed by Employer / Employer's representative.The rate includes necessary connected minor civil works if required and necessary supports as required at site. No extra payment will be made for the same. etc., complete complying with relevant standard specifications and as directed by SIPCOT officers.

2

-

-

... More
EARTHING ,CABLE TRAYS AND MS ITEMS -EARTH FLAT-Supply and laying of following sizes of cu / GI strips with all necessary accessories to be laid on ground / wall/ on tray etc. The cost is including the required bimettalic strip to make a smooth connectivity between GI and copper stip and also the cost is including the excavation and refilling the soil. The strip should be run minimum 600mm depth from finished ground level if burried in ground directly. (On non availability of specified flat / strip size, immediate higher size strip must be provided).

-

-

-

... More
Supply and laying of 25 x 6 mm G.I flat

250

-

-

... More
Supply and laying of 25 x 3 mm G.I flat

250

-

-

... More
Supply and laying of 8 gauge bare copper wire

500

-

-

... More
EARTHING ,CABLE TRAYS AND MS ITEMS -Supply and laying of earth station made up of 500mm length 50 x 6 mm CU. flat with necessary insulators at both end, Making required holes and filled with suitable size bolt, nut and double washer etc. as required. etc., complete complying with relevant standard specifications and as directed by SIPCOT officers.

4

-

-

... More
POINT WIRING, CONDUITS & WIRINGS, SWITCH & SOCKETS AND RACEWAYS & JUNCTION BOXES.-Wiring to the Circuit mains (DB to switch board / first point of power socket) using 3 Runs of 2.5sqmm (Phase, Neutral + Earth conductor) multi strand PVC insulated copper conductor (FRLS) in 20mm dia. MS conduit in open system in above false ceiling and concealed system in below false ceiling with all other necessary accessories, all complete complying with relevant standard specifications-All installation works should be as complete and as directed by Employer / Employer's representative.-The rate includes necessary connected minor civil works if required and necessary supports as required at site. No extra payment will be made for the same. etc., complete complying with relevant standard specifications and as directed by SIPCOT officers.

520

-

-

... More
POINT WIRING, CONDUITS & WIRINGS, SWITCH & SOCKETS AND RACEWAYS & JUNCTION BOXES.-Wiring to the Circuit mains (DB to switch board / first point of power socket) using 6Runs of 2.5sqmm (2Nos of single phase circuit and each should have Phase, Neutral & Earth conductor) multi strand PVC insulated copper conductor (FRLS) in 25mm dia. MS conduit in open system in above false ceiling and concealed system in below false ceiling with all other necessary accessories, all complete complying with relevant standard specifications-All installation works should be as complete and as directed by Employer / Employer's representative.-The rate includes necessary connected minor civil works if required and necessary supports as required at site. No extra payment will be made for the same. etc., complete complying with relevant standard specifications and as directed by SIPCOT officers.

230

-

-

... More
POINT WIRING, CONDUITS & WIRINGS, SWITCH & SOCKETS AND RACEWAYS & JUNCTION BOXES.-Wiring to the Circuit mains (DB to switch board / first point of power socket/AC) using 2 Runs of 4sqmm + 1 Run of 2.5sqmm (Phase, Neutral + Earth conductor) multi strand PVC insulated copper conductor (FRLS) in 20mm dia. MS conduit in open system in above false ceiling and concealed system in below false ceiling with all other necessary accessories, all complete complying with relevant standard specifications-All installation works should be as complete and as directed by Employer / Employer's representative.-The rate includes necessary connected minor civil works if required and necessary supports as required at site. No extra payment will be made for the same. etc., complete complying with relevant standard specifications and as directed by SIPCOT officers.

100

-

-

... More
POINT WIRING, CONDUITS & WIRINGS, SWITCH & SOCKETS AND RACEWAYS & JUNCTION BOXES.-Wiring to the light points using 3Runs of 1.5sqmm multistrand PVC insulated FRLS copper wirein 20 mm MS conduit for primary point(switch to first point) and 3Runs of 1.5 Sqmm multi strand PVC insulated FRLS copper wire in 20mm MS conduit for secondary point (point to point looping), on direct ceiling /wall/ on tray etc.. The primary point wiring shall be concealed system below the false ceiling and open system at above false ceiling. The primary point rate should inclusive of supply and fixing of 6A modular type switch in a suitable size modular box in concealed system, the primary & secondary point rate should inclusive of supply, laying of GI flexible hose for lighting drops from ceiling, all complete complying with relevant standard specifications ( Roof PVC conduit ) all complete complying with relevant standard specifications-All installation works should be as complete and as directed by Employer / Employer's representative.-The rate includes necessary connected minor civil works if required and necessary supports as required at site. No extra payment will be made for the same. etc., complete complying with relevant standard specifications and as directed by SIPCOT officers.

-

-

-

... More
Primary point

450

-

-

... More
Secondary point

615

-

-

... More
SWITCH AND SOCKETS: Supply, fixing, testing and commissioning of Modular Switch & Socket combination in suitable modular box and Metal Clad sockets with MCB in Open/Recessed system.The necessary civil works shall be done for connected works and no extra payment will be made for the same etc., complete complying with relevant standard specifications and as directed by SIPCOT officers.

-

-

-

... More
1No 6A 240V 3pin Socket Controlled by 6A SP Switch with suitable size front plate and surface / metal box in open / recessed system.

100

-

-

... More
2Nos 6/10/13A 240V Universal Socket Controlled by 1no. 16A SP Switch with suitable size front plate and surface / metal box in open / recessed system.

100

-

-

... More
LIGHTING LUMINAIRES-Supply, Fixing, testing and commissioning of the following light fittings with all other necessary accessories.The rate shall be inclusive of suitable MS supports,GI Clamps and gripple make cable with crimp arrangement ,and chain suspenders .The height of the hanging arrangement shall be as per drawing and with all accesories to fix the hangers at purlin, rafter beam ,MS supports and walls with required clamps nuts & bolts to be considered. Also the rate includes necessary connected minor civil works if required and necessary supports as required at site. No extra payment will be made for the same.All installation works should be as complete and as directed by Employer / Employer's representative.Samples to be submitted and get approval fom Architect / Consultant before procurement.For LED light fittings, the complete luminaire should have a warranty for 5 years which includes the housing + LED + Driver -Supply of 15W Recess mounted LED downlighter made of pressure die cast aluminum housing with high efficiency reflector , LED used shall be SMD type and fixture should have minimum efficacy at system level (Non Chip Level)=100lumens / watt,Life of fixture(including Driver):50K Hrs.@L70B50 Lumen Maintance , CCT upto 4000 , CRI80 , PF 0.95 & THD10% , an operating voltage range of 140 - 270V. minumum internal surge protection 2.0KV the fixture design should comply with IS10322 , EMC / EMI compliance maintaining driver leakage current as per IEC 60598 , minimum system Lumens 1200 , Philips - DN296B LED15S PSU WH etc., complete complying with relevant standard specifications and as directed by SIPCOT officers.

150

-

-

... More
Supply, fixing, testing and commissioning of 4 feet 2 x 18w led tube type light fitting with reflector. etc., complete complying with relevant standard specifications and as directed by SIPCOT officers.

300

-

-

... More
Supply, fixing, testing and commissioning of the following cable etc., complete complying with relevant standard specifications and as directed by SIPCOT officers.

-

-

-

... More
4C x 6 Sqmm PVC Cu. Ar. cable.

250

-

-

... More
4C x 4 Sqmm PVC Cu ar. cable.

75

-

-

... More
3C x 4 Sqmm PVC Cu ar. cable.

40

-

-

... More
Excavation of the 300mm(W) x 750mm(D) cable trench in soil including river sand cushioning (150mm thick both at top and bottom of the cable), brick protection covering (size of brick 220 x 100 x 70 mm) after laying the cable,back filling, ramming and compacting the soil,etc., as required. etc., complete complying with relevant standard specifications and as directed by SIPCOT officers.

30

-

-

... More
Excavation of the 600mm(W) x 1000mm(D) cable trench in soil including river sand cushioning (150mm thick both at top and bottom of the cable), brick protection covering (size of brick 220 x 100 x 70 mm) after laying the cable,back filling, ramming and compacting the soil,etc., as required. etc., complete complying with relevant standard specifications and as directed by SIPCOT officers.

25

-

-

... More
Supply, providing, construction of following size Masanory inspection (Man hole) chamber with cover for hume pipes .The man hole cover shall be provided with heavy duty CI/RCC type for inspection chamber. etc., complete complying with relevant standard specifications and as directed by SIPCOT officers.

-

-

-

... More
Chamber size: 450x450x1000mm

4

-

-

... More
Test link (at every down conductor)

11

-

-

... More
GI Strip (25x6 mm)

350

-

-

... More
Earthing: C-Bar 3/4" dia, UL listed, 3000 mm long + 22.6 Kg GC+ and clamp for termination. Including 750mm x 750mm x 3mtr long excavation and construction of 850mm x 850mm x 300 mm high brick wall chamber with cement mortor. The chamber shall be provided with 450mm x 450mm x 10mm cast iron / RCC cover with frame and lockable facility. The Cover shall be heavy duty to suit heavy vehicle movements. etc., complete complying with relevant standard specifications and as directed by SIPCOT officers.

10

-

-

... More
DG SET AND ALLIED WORKS- Design, Manufacture, Transportation, Supply, Installation, Testing and Commissioning of radiator water cooled 125 KVA DG set, 1500 rpm, four stroke,designed for operating on 415V, 50 Hz, 0.8 pf, complete with all accessories, like base frame, fuel tank of 990 litres,batteries 12V or 24V suitable for starting of the DG Set with standard control panel and includes the following transport, insurance, handling, safe keeping at site etc., erection, installation, testing and commissioning including performance tests as per Specifications. The necessary foundation will be provided by other agency.The rate shall also include the following Acoustic enclosure,Isolator panels if required Silencer Earth flats for body and neutral.Necessary Cables Safety equipments,Safety equipments Ms angles will be measured & paid as per actuals as per site condition Exhaust stack etc., complete complying with relevant standard specifications and as directed by SIPCOT officers.

1

-

-

... More
UPS SYSTEMS-Supply, Installation, Testing and commissioning of 2KVA UPS system 3 phase input and three phase output andas per the detailed specification enclosed.All UPS/ INVERTER should have at least one spare potential free contacts to integrate with BMS system to know the status like ON, OFF, TRIP, etc., complete complying with relevant standard specifications and as directed by SIPCOT officers.

2

-

-

... More
Supplying and fixing of Glvanized ply barbed wire fencing including cost of fencing wire and all labour chargwes for tying etc., complete complying with relevant standard specifications and as directed by SIPCOT officers.

1700

-

-

... More
Providing Expansion joint of bitumen pad 20mm thick with fixing completed and as directed by SIPCOT officers.

4

-

-

... More
Supply and delivery of Open well Submersible pump set conforming to IS 14220 /2002 and as amended thereafter and BEE 3 Star Rated capable of discharging the following duties due to all causes. The pump shall be with stainless steel shaft and dynamically balanced bronze mixed type impeller, CI FG 200 grade casing and brass screws and rotor shall be of copper rod as per IS 613/1984 with ISI mark. The pump suitable for installation in sump with 1.1KV grade 3 core suitable copper flat submersible cable to a length of 15m with necessary cable joints. The non-return valve located at the top of the pump in the discharge outlet connection is to be designed with minimum friction. The pump should be directly coupled to 2880 RPM, three phase, 50 Hz (±5), 415V+6% & 415V-15% squirrel cage induction motor suitable for DOL upto 5 HP, Fully Automatic Air break Star Delta up to 20 HP and Auto Transformer starter for above 20 HP starting and for continuous operation.-1500 LPMx40 H etc., complete complying with relevant standard specifications and as directed by SIPCOT officers.

1

-

-

... More
Supplying and erecting in position of following liters capacity Industrial Model Reverse Osmosis Water-cum- Purifier to deliver Potable Water with World Health Organisation (WHO) Standards with following accessories.(a) MS Skid- 1 No.(b) Media 11054 No. Vessel with 20 nb Multiport Valve(with Media Pubble and Fine Sand and Activated Carbon Filling) set(c) Feed Pump 0.50 HP 1 No.(d) Vertical Pump 2-9, 2.00 HP/Single Phase 1 No.(e) Membrane 40 x 40 filmtech (or) equilaents /Osmonic (USA)- 1 No. and Membrane Pressure Vessel40 x 40 -1 No. & Pressure Gauge - 2 Nos.(f) Flow Meter - 1 No. 20" Filter with Housing - 1 No., Low Pressure Switch- 1 No., Level Switch - 1 No. &Necessary CPVC Pipes and Fittings.The system shall be provide with Two Panel ControlSystem with necessary Stainless Valves and Fittingsand Float Control etc. The rate should be inclusive of allcivil works, wherever necessary to install the System inposition and intact.-2000 Litres etc., complete complying with relevant standard specifications and as directed by SIPCOT officers.

1

-

-

... More
Manufacturing, supplying & erection of 5 mtr long full galvanised Hexagonal street light pole swaged welded 300mmx 300mmx 8mm thick base plate at bottom and provided with earth stud, and providing 1 nos 16 A kit kat fuse with 2 way terminal block inside the pole and water proof door locking arrengement, etc.,Manufacturing, supplying & erection of Single ornamental type Street light bracket made of approved type and design with 40 mm dia 1500mm over hanging 80mm colar from street light pole etc.,Excavation and providing CC (1:2:4) foundation of 450 mm dia X 2000 mm deep and foundation of size 450 mm X 450 mm X 200 mm height above ground level including providing & placing 16 mm dia 750 mm long foundation bolt with doublenut at top and providing reinforcement with 4 nos 12 mm dia X 2000 mm long TMT rod with 8 mm dia strip as per site condition. etc., complete complying with relevant standard specifications and as directed by SIPCOT officers.

24

-

-

... More
Supply and fixing 1 Nos 50 W LED lamps complete with all accessories on the existing bracket on street light poles i/c connection and loop earthing with 2 X 1.5 sqmm PVC insulated copper conductor cable from street light box and fixing testing and commissioning etc., (Make IS) etc., complete complying with relevant standard specifications and as directed by SIPCOT officers.

24

-

-

... More
Supply and erection of street light timer switch outdoor type board size of 1000 X 800 X 250 mm compartmentelized and cubicle type front operated totally enclosed weather proof dust proof suitable for 240 volts AC supply with following accessories made out of 2 mm thick CRA MS sheet and poweder coated painting and interconnection etc.,INCOMMING a) 63 A rewirable fuses - 3 nos. b) Neutral link - 1 nos. c) 6 mm hylam sheet and slated channel for EB meter fixing. - 1 lot d) 63 Amp TPN HRC fuse switch - 1 no. OUTGOING a) 40 Amps 4 pole contactor MNX22 - 2 no. b) 24 hours timer switch LT GIC - 1 no. c) Auto / manual selector switch LT - 1 no d) LED indicator lamp - 1 nos. e) 20 Amps SP MCB - 3 nos. etc., complete complying with relevant standard specifications and as directed by SIPCOT officers.

1

-

-

... More
Trench excavation depth of 0.75 meter at road and 0.15 meter depth sand cushing and refilling the trench. b) Supply and laying 32 mm High Density Poly Ethelene pipe with necessary accessories for street light main line laying directly in existing trench. etc., complete complying with relevant standard specifications and as directed by SIPCOT officers.

320

-

-

... More
Supply and laying of 4 core X 16 sqmm PVC armoured LTUG cable in existing DWC pipe etc., complete complying with relevant standard specifications and as directed by SIPCOT officers.

320

-

-

... More
Providing earthing with 2.5 mts long 40 mm dia GI pipe including all accessories and providing masanory encloser with cover plate locking arrengement with charcoal, coke and salt etc., etc., complete complying with relevant standard specifications and as directed by SIPCOT officers.

2

-

-

... More
Part - B - 10 Metre High Mast

-

-

-

... More
Supply delivery and erection of full galvanised high mast of 10 mtr height fixed carriage and suitable to withstand a wind speed of 140Km/Hr a) Casting foundation with suitable design to the above mast to withstand 140Km / hour with reinforcement sand including foundation bolt nuts b) supply of 150 W LED FLOOD light fitting complete 6 X 150 Wd) Erection of 10 meter high mast using special equipments crane and fixing LED luminaries internal wiring earthing the mast and the panel board erection and earthing of panel board and termination of input supply. etc., complete complying with relevant standard specifications and as directed by SIPCOT officers.

4

-

-

... More
Supply and laying of 2 X 25 sqmm PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 meter putting 0.15 mtr. Layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good. etc., complete complying with relevant standard specifications and as directed by SIPCOT officers.

100

-

-

... More
Supply and erection highmast light of street light control box outdoor type 1000X500X250 mm compartmentelized front operated totally enclosed weather proof and dust proof made out of 2mm thick MS sheet and powder coated painting, interconnection and following accessories. a) 63 A rewireable fuse - 1 nos b) Neutral link - 1 no. c) Hylam sheet cover and slated channel for EB meter fixing - 1 no. d) 63 A DP cubical HRC fuse switch - 1 no. etc., complete complying with relevant standard specifications and as directed by SIPCOT officers.

4

-

-

... More
Providing earthing with 2.5 mts long 40 mm dia GI pipe including all accessories and providing masanory encloser with cover plate locking arrengement with charcoal, coke and salt etc., complete complying with relevant standard specifications and as directed by SIPCOT officers.

1

-

-

... More
Part - C - Garden Light

-

-

-

... More
Supply and fixing 15 W LED Garden light fitting complete with all accessories loop earthing with 2 X 1.5 sqmm PVC insulated copper conductor cable with suitable foundation etx(Make IS) etc., complete complying with relevant standard specifications and as directed by SIPCOT officers.

15

-

-

... More
a) Trench excavation depth of 0.75 meter at road and 0.15 meter depth sand cushing and refilling the trench.b) Supply and laying 32 mm High Density Poly Ethelene pipe with necessary accessories for street light main line laying directly in existing trench. etc., complete complying with relevant standard specifications and as directed by SIPCOT officers.

250

-

-

... More
Supply and laying of 2 core X 10 sqmm PVC armoured LTUG cable in existing DWC pipe etc., complete complying with relevant standard specifications and as directed by SIPCOT officers.

250

-

-

... More
Supplying and fixing glass reinforced with knockouts thermo plastic/SMC cable junction box of following size with IP66 ingress protection on wall surface using suitable clamps/fastners, alongwith supplying and fixing 1 no. 5 Way connection block with 2 clamping units per pole, connections etc. as required. etc., complete complying with relevant standard specifications and as directed by SIPCOT officers.

-

-

-

... More
Supply and Fixing of 250 mm x 200 mm x 100 mm, 10-25 sqmm terminal capacity (Nominal) (For terminating incoming cables) etc., complete complying with relevant standard specifications and as directed by SIPCOT officers.

8

-

-

... More
Supplying and fixing of 45W (H), LED gate light/ post top lantern fitting with die cast aluminium base, lamp compartment encased in non-yellowing transflucent UV stabilised acrylic diffuser, spun aluminium top cover, body finished in polyester powder coated black shade, IP54 ingress protection, 10kV surge protection etc suitable for operation on 230V AC, 1 phase, 50 Hz input power supply on existing bracket/ light pole as required. etc., complete complying with relevant standard specifications and as directed by SIPCOT officers.

4

-

-

... More
Supplying and fixing of following RoHS and EMC compliant LED flood light with high pressure die cast aluminium housing, IP66 ingress protection, tempered glass cover, individual lense over LED for glare control, 10kV surge protection, narrow/wide beam optics as per requirement etc suitable for operation on 230V AC, 1 phase, 50 Hz input power supply with following specifications. etc., complete complying with relevant standard specifications and as directed by SIPCOT officers.

5

-

-

... More
Part D - Wiring

-

-

-

... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C etc., complete complying with relevant standard specifications and as directed by SIPCOT officers.

25

-

-

... More
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. etc., complete complying with relevant standard specifications and as directed by SIPCOT officers.

40

-

-

... More
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire etc., complete complying with relevant standard specifications and as directed by SIPCOT officers.

40

-

-

... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 16 way, Double door etc., complete complying with relevant standard specifications and as directed by SIPCOT officers.

4

-

-

... More
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc., as required (But without MCB/RCCB/Isolator) 4 way (4+12), Double Door etc., complete complying with relevant standard specifications and as directed by SIPCOT officers.

2

-

-

... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testingand commissioning etc. as required. etc., complete complying with relevant standard specifications and as directed by SIPCOT officers.

-

-

-

... More
Single pole

24

-

-

... More
Triple pole and neutral

2

-

-

... More
Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 amps etc., complete complying with relevant standard specifications and as directed by SIPCOT officers.

4

-

-

... More
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. etc., complete complying with relevant standard specifications and as directed by SIPCOT officers.

2

-

-

... More
Supplying and laying of 4 core 35 sqmm 1.1 KV grade XLPE insulated, PVC sheathed, armoured, aluminium conductor power cable confirming to IS 7098/ part 1/1988 of the following sizes and Providing and fixing 2 nos 4.00 mm dia copper wire for loop earthing in the existing wall Clamped with 2mm thick Saddle on surface as reqd. ( for Main panel to DB power supply) etc., complete complying with relevant standard specifications and as directed by SIPCOT officers.

40

-

-

... More
Providing Cable End terminations etc., complete complying with relevant standard specifications and as directed by SIPCOT officers.

15

-

-

... More
Part E - Paver Block - External Road

-

-

-

... More
Supplying and filling in foundation and basement with Hard Gravel in layers of not more than 30 cm thick well rammed watered and consolidated etc.,complete complying with standard specifications and as directed by "SIPCOT" officers.

320

-

-

... More
Construction of Granular Sub - Base (GSB) to the required compacted thickness (Drainage layer) by providing approved Coarse graded material conforming to Grading- V of Table 400 - 1 and satisfying the physical requirement for material for GSB as per Table 400 - 2 of MORTH Rev.-5 including screening, spreading in uniform layers with motor grader on prepared surface, watering and premixing by mix in place method with rotavator at OMC, and compacting with Vibratory roller 80 to 100 KN static weight to achieve the desired density and fine dressing to required grade and cross slope as directed by the SIPCOT officers etc., complete including obtaining and transporting all materials from approved quarry site to work site with all lift and lead by mechanical transport, head load or any other mode of transporation including cost and conveyance of all materials, labour charges,hire charges and fuel charges for loader, water tanker with sprinkler,motor grader, vibratory road rollers and required including all other incidental charges, etc., complete as per the standard specification as per clause 401 of MORTH Rev.-5 and as directed by the SIPCOT officers.

250

-

-

... More
Supplying and laying 83 mm thick mix vibro compacted M50 grade heavy duty road paver interlocking block with super embedded anty skid with texture design meeting their international standard size with Zig Zag design with higher loading capacity rate including cost and conveyance all required materials at site and all labour charges for laying, compacting with paver vibrator and lall taxes etc., complete complying with standard specification and as directed by SIPCOT Officers.

1040

-

-

... More
Providing kerb wall fixing as per type design enclosed herewith, by using PCC 1:2:4 of size 150mmx565mm using 20mm HBG Stone jelly, including centring for side wall and excluding cost of reinforcement and including cost and conveyance of all materials, labour charges and hire charges for all tools and plants employed etc.,complete complying with standard specification and as directed by SIPCOT officers.

365

-

-

... More
Supplying and fixing FRP rain water Gutter including cost of labour charges nd mteril chrges etc.,completetd nd as directed by SIPCOT Officers

145

-

-

... More
Supplying, laying, fixing and jointing the160 mm dia 10 kg/cm2 PVC pipes including the cost of suitable PVC/GI specials /GM specials like Elbow, Tee reducers, Plug, union, bend, coupler, nipple/ GM gate valve, check and wheel valve etc., wherever required above the ground level including the cost of teflon tape, special clamps, nails, etc., fixing on wall to the proper gradient and alignment and redoing the chipped of masonry etc., complete complying with relevant standard specifications and as directed by SIPCOT officers.

160

-

-

... More
Supply of Stainless steel water dispenser P80 NHC -Water Storage Capacity :120 LCooling Capacity :60 L/hwith all accessories fro delivery point etc ., completed and as directed by SIPCOT officers

8

-

-

... More
Sub Total of Total Amount in Column BA (ie. Qty x Unit Rate)

-

-

-

... More
Added GST of 18%

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.