State Industries Promotion Corporation Of Tamil Nadu Limited Tender

Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.

State Industries Promotion Corporation Of Tamil Nadu Limited - SIPCOT Tender

Works
Civil And Construction
Pipe Line Project
Eprocure
Opening Date12 Jun 2024
Closing Date26 Jun 2024
Tender Amount₹ 56,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Earthwork excavation for pipe laying in all soils such as other than loose soil inclding refilling as per standard specification and as directed by SIPCOT Officials

490

-

-

... More
Supplying 250mm dia DI pipe K7 socket/ Spigot as per standard specification and as directed by SIPCOT Officials.

1040

-

-

... More
Lowering of 250mm DI pipe K7 S/S as per standard specification and as directed by SIPCOT Officials.

1040

-

-

... More
Testing of pipes for water supply with hydralic testing equipment by filling with water (including cost of water) and testing to recommended pressure in convenient stretches and attending the bursts if any occurred during the test, excluding the cost of pipes but including other incidentall and operational charges etc., complete for the laid diametres of pipes.

1040

-

-

... More
Barricading work (Where, there is less traffic areas and broader roads etc.) for laying of pipe line using casurina poles at 1.50m center to centre (8cm to 10cm dia and 1.80m height) vertical with horizontal poles in three rows including painting the vertical poles in the road facing sides with ready mix paint, tying the vertical and horizontal poles with coir rope including fixing charges and fixing 75mm dia reflectors including earht work excavation for fixing vertical posts and finally removing and stacking the materials safely for further use etc. complete and as directed by SIPCOT Officials.

2080

-

-

... More
Jointing of 250mm dia DI S/S pipes as per standard specification and as directed by SIPCOT Officials

195

-

-

... More
Earthwork excavation and depositing for foundation in hard stiff clay, hard red earth etc. SS 20B specification., and as directed by SIPCOT Officials.

-

-

-

... More
For Fixing of 400 x 250mm DI Reducer Tee

38

-

-

... More
Cutting 400mm DI pipes true to axis and filling smoothly and finishing the ends complete and as directed by SIPCOT officers

4

-

-

... More
Suppy and fixing of mechanical Joint collor and as directed by SIPCOT Officials.

-

-

-

... More
400mm dia

1

-

-

... More
250mm dia

4

-

-

... More
Providing the following size of DI D/F Gate valve as per standard specification and as directed by SIPCOT Officials.

-

-

-

... More
400 mm dia

1

-

-

... More
250mm dia

1

-

-

... More
Supplying and jointing of the following specials as per standard specification and as directed by SIPCOT Officials.

-

-

-

... More
400 x 250mm DI Reducer Tee

101

-

-

... More
400mm flange socket

244

-

-

... More
250mm flange spigot

32

-

-

... More
250mm DI 90 degree bend

92

-

-

... More
250mm DI 22.5 degree bend

62

-

-

... More
250mm DI 11.25 degree bend

28

-

-

... More
Jointing the above speicals with rubber insertion and MS bolts & nuts

-

-

-

... More
400 mm DI

5

-

-

... More
250mm DI

6

-

-

... More
Refilling the trench with excavated soil as per standard specification and as directed by SIPCOT Officers

12.5

-

-

... More
Supply & Fixing of 250mm dia Electromagnetic Flow Meter. The Electromagnetic Flow Meter shall be a velocity sensing Electromagnetic type, microprocessor based signal converter, sealed housing, flanged tube meter for 1.0 Mpa working pressure, manufactured to highest standard available for mag-meters, equipped with minimum six digit digital totalizers, reading in different units (Kiloliters / Cubic meter) and shall be accurate within 0.5% of Measured value, shall operate within a range of 0.3 m/sec to 4 m/sec and be constructed as follows: Meter tube (Sensor) shall be fabricated from stainless steel tube and use class PN10 flat face carbon steel flanges in accordance with IS 1538. These flanges shall be welded to the flow tube. The internal and external of the meter tube shall be blasted to near white and lined with hard rubber/ Polyurethrene/ PTFE preferably by SBR or EPDM. Meter tube shall have a constant nominal inside diameter offering no obstruction to the flow. The accuracy should be inclusive of linearity, hysteresis, repeatability, temperature and pressure effects. Coil Housing shall be fabricated from stainless steel (SS304)/ Die cast Aluminium/ Carbon steel with anti corriosive paint for corrosion resistance and welded to the tube providing a completely sealed environment for all coils, electrode connections and wiring harness capable of submerged or buried operation with IP68 Protection. Signal Converter shall be pulsed DC coil excitation type with auto zeroing. The signal converter shall be remotely mounted away from the meter. The converter shall indicate direction of flow and provide a flow rate indication and a total of flow volume for both forward and reverse directions. The converter shall provide an isolated 4-20 mA output into minimum 500-ohm load and a frequency output of a maximum of 0-10 KHZ and a scaled pulse output. The microprocessor based signal converter shall have a self-diagnostic test mode and a backlit display that continuously displays "Rate of Flow" and "Total Volume". Converter shall be supplied with a programmable low flow drop out, higher flow and empty pipe zero return. The signal converter housing should be die-cast aluminum with glass window. The converter cum transmitter should be fully programmable from the front facia. The programming should be user friendly, self-prompting menu driven. Flow meter test calibration certificate from FCRI, flow test lab / NABL accredited lab to be furnished.

1

-

-

... More
Providing valve chamber of following size with necessary Earth work, Stone dust filling 0.15m thick, PCC 1:4:8 .015m thick, Brick work in CM 1: 3, RCC 1:2:4 including Centering, Steel etc Complete and providing FRC manhole cover of 0.6m x 0.6m etc., Complete and as directed by SIPCOT Officers.

-

-

-

... More
1.35 x 1.35 x 1.95 M

1

-

-

... More
1. 35 x 1.20 x 1.55 M

2

-

-

... More
Sub Total of Total Amount in Column BA (ie. Qty x Unit Rate)

-

-

-

... More
Added GST of 18%

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.