State Agricultural Marketing Board Tender
Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.
State Agricultural Marketing Board Tender
Civil And Construction
Building Construction
Eprocure
Opening Date16 Nov 2024
Closing Soon25 Nov 2024
Tender Amount₹ 4,49,86,000
Costs
EMD
₹ 5,31,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_TAMBC_501973_1Tender No
TNSAMB-2024-27-03Tender Authority
State Agricultural Marketing Board ViewPurchaser Address
-Website
http://tntenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Cement Concrete 1:5:10 (One Cement, Five M sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete complying with standard specification
369.1
-
-
Plain Cement Concrete 1:2:4 (one cement, two M sand and four hard broken stone jelly) using 20mm jelly for wearing coat including laying, compacting, finishing and curing, etc., complete as per standard specificatins and as directed by the departmental officers.
34.8
-
-
Cement Concrete 1:2:4 (One Cement, Two M sand and Four hard broken stone jelly) using 20 mm gauge hard broken granite stone jelly for all RCC items of works excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary and bearing surfaces of walls, beams etc. shall be finished smooth with Cement Mortar 1:3 (One Cement and Three M Sand) and kraft paper laid over it without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers
-
-
-
a) For Foundation and Basement
99
-
-
Cement Concrete 1:1-1/2:3 (One Cement, One and a half M sand and Three hard broken stone jelly) using 20 mm gauge hard broken granite stone jelly for all RCC items of works excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary and bearing surfaces of walls, beams etc. shall be finished smooth with Cement Mortar 1:3 (One Cement and Three M Sand) and kraft paper laid over it without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers
-
-
-
a) For Foundation and Basement
491.1
-
-
b) For Super Structure in Ground Floor up to 4.50 M ht
182.2
-
-
c) For First floor
8.5
-
-
Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel grills for all RCC works as per design given including cost of steel and G.I. binding wire in all floors etc. complete complying with standard specification. (Contractor has to make his own arrangements for the supply of steel and binding wire)
630.25
-
-
Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid)
-
-
-
a)For column footing plinth beam bed blocks templates staircase, steps piers raft beam raft slab etc.,
1168.3
-
-
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid)
-
-
-
a) For plane surfaces such as RCC floor slab, roof slab, beams, lintels, bed blocks, landing slab, waist slab, portico slabs and beams, etc.
973.1
-
-
b) For plane surfaces such as rectangular or square RCC columns, sunshades, top and bottom slab of RCC boxing, etc
1049.5
-
-
Providing additional strutting to centering of RCC slabs of plain surface for every additional 1.0 metre height or part thereof but not less than 30 cm, over the initial 3.00 metre height from floor level using casurina props of 10cm to 13cm dia including cross bracing etc., complete complying with standard specification and as directed by the department officers.
-
-
-
a) For 3.30 m to 4.30 m
3.6
-
-
b) For 4.30 m to 5.30 m
3.6
-
-
c) For 5.30 m to 6.30 m
14.1
-
-
Brick work in following Cement Mortar using 1:5 Fly Ash Bricks of 230 x 110 x 70mm size conforming to IS: 12894-1989 Class designation not less 50 kg./ sq.cm. average compressive strength in cement mortar 1:5 for load bearing structures for foundation and basement and for superstructure including curing, etc., complete complying with standard specifiction.
-
-
-
a) For Foundation and Basement
160
-
-
Brick work in following Cement Mortar using 1:6 Fly Ash Bricks of 230 x 110 x 70mm size conforming to IS: 12894-1989 Class designation not less 50 kg./ sq.cm. average compressive strength in cement mortar 1:5 for load bearing structures for foundation and basement and for superstructure including curing, etc., complete complying with standard specifiction.
-
-
-
a) For Super Structure in Ground Floor up to 4.50 M ht
218
-
-
b) In Second floor
1.7
-
-
Brick partition walls of 11.50cm thickness using Fly Ash Bricks of 230 x 110 x 70mm size conforming to IS: 12894-1989 Class designation not less 50 kg./ sq.cm. average compressive strength in Cement Mortar 1:3 (One Cement and Three Sand) using hoop iron reinforcement if found necessary including curing etc. complete and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately)
81.5
-
-
Plastering with Cement Mortar 1:5 (One cement and Five sand), 12mm thick in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers.
3639
-
-
Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three Sand) 10mm thick including hacking the surfaces, providing cement mortar nosing, beading for sunshades, staircases, steps, landing slabs and curing, etc., in all floors complying with standard specification and as directed by the departmental officers
965.8
-
-
Painting two coats of newly plastered wall surface with ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification.
4145
-
-
Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
265
-
-
Fabricating and supplying and erecting the required number of trusses with structural steel members like angle iron MS plates for all truss members including cleats to receive the purlines all cutting drilling holes welding and fixing of members with necessaryThe welding should be done with submerged arc welding to full length. The rate inclusive of the cost of painting the memebers with one coat of primer of Zinc chromite and enamel paint etc., complete
12349.99
-
-
Fabricating supplying and erecting the Pre-engineered steel building structure using Galvanised structural steel sections, conforming to Grade 50 with yield strength of 345MPa baseplate, Sag Rods, struts including cleats to receive 'Z' and 'C' purlins, cutting, drilling holes, welding, grinding fixing the members with nessary bolts nuts, anchor bolt of approved quality, hoisting, aligning and placing the 'I' sections in position as per the design got approved from the department, fixing purlins with Sag Rods, supporting the purlins from the beams on both sides. The welding should be done with submerged arc welding to full length. The rate inclusive of the cost of painting the memebers with one coat of primer of Zinc chromite and enamel paint etc., complete complying with standard specification and as directed by the departmental officers, etc., complete.
33600
-
-
Supplying and fixing in position of Iron grills of required size using 32 x 32 x 6mm angle around and 2 Nos of vertical at center with MS flats diagonally to the existing open space for grills into necessary hold fast conveyance and one coat of primer etc., complete
600
-
-
Supplying and laying of Profiled Galvalume Sheet of TCT 0.47 mm and standard width of 1.060 mm with yield strength of 550 MPA of approved quality for roofing with necessary U or J bolts and unts bitumen GI washers etc., complete complying with standard specification and as directed by the departmental officers during execution of work
1930
-
-
Supplying and fixing corrugated PolyCarbonate Sheet of size 3mx1.06m on the roof in between the colour coated Galvolume sheets for proper lighting with necessary screws and EPDM rubber washers, etc. as complete Complying with standard specification and as directed and specified by the departmental officers.
24
-
-
Supplying and fixing of Rotary Ventilators with all purlins on the roof with necessary bolt & nut arrangement to with stand the wind velosity as specified by the departmental officers.
6
-
-
Supplying and laying of Gal volume sheet ridge pieces approved quality with necessary U or J bolts and nuts GI washers etc., complete complying with standard specification.
78.5
-
-
Providing Groove cutting in flooring concrete for 10mm width and 20mm depth and filling the groove with combination of Anabond Tuffseald 2G and bitumen tar including cost of all materials and labours etc complete.
375
-
-
Weathering course in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no sand to be used) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the deparmental officers.
50.6
-
-
Finishing the top of roof with one course of machine pressed tiles of size 230mm x 230mm x 20mm of approved quality set in Cement Mortar 1:3 (One Cement and Three Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers
557.5
-
-
Flooring with following ceramic tiles of size 305 x 305 x 6 mm laid over 20 mm thick cement mortar 1:3 (One Cement and Three Sand) base mortar over the existing slab / floor including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with white cement mixed with colouring pigment at the rate of 0.3 Kg. / sq.m. etc., complete complying with standard specification. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
29
-
-
Dadooing walls with following best approved quality, white / colour glazed tiles of following sizes set in Cement Mortar 1:2 (One Cement and Two sand) 10mm thick and pointing the joints with white cement mixed with colouring pigments at the rate of 0.40 Kg. / sq.m. neatly in all floors, curing, etc., complying with standard specification and as directed by the departmental officers.
-
-
-
300 X 450 X 6mm
74
-
-
Supplying and fixing of rolling shutters with ISI mark shall be of pull and push type made out of 18/Gauge x3’’ lathe sections which consists of five main parts such as curtain, lock plate, guide channels rollers and hood cover. These five main parts are made out of special components detailed below; Curtain; Shall be of 18/Gx3' lath sections cut to required size and filled with heavy cast iron/ M.S. Clips for 8'0"[2.45m] high rolling shutter lathe sections provided shall be not less than 37 numbers. Lock Plate; Shall be 10gaue M.S.Sheet reinforced with 40mmx 6mm M.S angles at the bottom and fitted with heavy latches of 12mm thick locking arrangements on either sides. There should be one handle on either side Guide channel; Pressed guide channels shall be of 10 gauge M.S.Sheet and attached to the side brackets with 20mm square bar. Side brackets shall be of 10 Gauge angle M.S.Plate and cost iron 'U' clamps shall be reveted to the side brackets Roller; Shall be of heavy cast iron pullies fitted with heavy duty C' Class 40mm steel pipes and high tensile high carbon coil springs-2 springs shall be supplied. Supplying and fixing of Hood Cover; Shall be of 0.9mm CRCA sheet reinforced with 25mm x 25mm x 3mm M.S. angle or gate channel. The rolling shutter in addition to the above should have pulling hook and shall be coated with heavy coat of zinc chromite primer. The above specifications for various components of rolling shutter shall be invariably followed and verified with the rolling shutters supplied by the firms at site. If the rolling shutters supplied do not confirm to the above specifications, the concerned firms should be asked to replace the shutter or supply the missing components
-
-
-
Manually operated (up to 8 m2 area)
87.6
-
-
Fabricating, Supplying and fixng in position of Steel Windows (Three Leaves) with the following specifications. Outer frames of windows made of 'Z' section F7D of size 33 x 25 x 3mm at 1.419 kg/ m and mullion 'J' section (F4B) of size 46 x 25 x 3mm at 2.28 kg/m and shutter section of made of F7D of 33 x 25 x 3mm at 1.419 kg/m as specified in IS 7452 / 1990. Each openable shutter should not exceed a width of 600mm to enable separate operations and easy maintenance. The panel of the shutters to be covered with 18 gauge cold rolled sheet of superior quality and welded intact with shutter frames. Horizontal stiffeners using 18 x 5mm MS Flat at 0.70 kg./m at 3 Nos. for each shutter and additional diagonal stiffners of the same MS flats at all the four corners of each shutters to the suitable length welded to the shutters, for holding the CR Sheets in position firmly. 2 numbers of sturdy hinges and one number of handle-cum-latch of special type made with 18 x 5mm MS flats are revetted to the shutters at an appropriate height in window. suitable opening is left for its easy operation. a stopper square rod for handle is provided in the mullion section at suitable place to catch the window handle. Each window shutter having an adustable stay made out of 18 x 5mm at 0.70 kg/m MS flat of lenght 320mm with three adjustable position. A matching peg is provided in the outer frame of the window at suitable place. 4 Nos. of hold fasts of 120mm length spliced at the ends are welded to the outer frame of the window by using MS flat of 18 x 5mm at 0.70 kg./m, welded to the shutter at two place equivalent from each from top and bottom of the shutter. An MS square bar of 12mm size is welded to the inner face of the window at an equal interval not exceeding 100mm edge between them. All members are painted with one coat of anti-corrosive red oxide primer as directed by the departmental officers.All sections should be in confirmed with IS 7452 / 1990.The cost includes cost of all materials, labour charges and other incidental charges, etc., complete
27
-
-
Manufacturing and supplying and fixing in position of 'N' type ventilators of required size made out of 25x25x5mm MS "L" angles frames alround the ventilator. MS TEE of 25x25x5 mm to be fixed in between the frames at 30 cm intervals. Hold fast to be used 25x25x5 mm "L" angle 23 cm length 4 Nos. 3 mm pin headed glass to be fixed in-between the angles by using Teak wood beadings of size 15x12 mm with screw, washer and nut wherever necessary. In the inclined portion, 1"x1" weld mesh to be embedded by using 25x5 mm Flat at 30 cm centre to centre. 12 mm sq. steel rods to be fixed horizontally between the frames in vertical portions at 10 cm centre to centre (approximately). The rate inclusive of transporting charge, dismantling, redoing to the original condition, one coat of red oxide primer etc., complete complying with standard specification and as directed by the departmental officers.
8.3
-
-
Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work
3.6
-
-
Supplying and fixing in position best approved of BIS quality PVC rain water down fall pipes having a pressure of 4 kg. / sq.cm including cost of necessry PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of "U" clamp at the centre of the pipe line in addition to those for more than 3.0 metre pipe length, etc., complete complying with standard specification and as directed by the departmental officers
36
-
-
Supplying and fixing of Electronic Weighing Scale of Size (240 x 300)mm with stainless steel platform with stainless steel back grill and bright LED display having capacity of (30Kg) with accuracy of (5gm). The display should be of with single phase AC with battery back up and display intensity adjustable for longer battery backup. The machine is also compatible with computer interface RS232 connectivity. The additional functions like indication for AC on net/gross weight, auto zero, battery, battery low count mode, tare function, over load protection with audio alarm and dust proof cover should also be provided in the above machine as directed by the Departmental Officers etc., complete. The rate includes conveyance and all other taxes etc.,
50
-
-
Solid PVC Door Shutters using 19 Gauge 19mm MS square tubes for styles and outer frames. 15mm MS square tubes for top, lock and bottom rails. The steel tubes shall be covered with 5mm thick solid PVC Sheets. Shutter using 5mm thick solid PVC Sheets for panelling shall rigidly fixed in position including necessary furniture and fittings. The over all size of styles shall be 50mm x 30mm. The over all size of top rail, lock rail and bottom rail shall be 75mm x 30mm. The over all size of frames shall be 50mm x 45mm with suitable rabate for housing the shutter.
-
-
-
Solid panel PVC door with frame
12.6
-
-
Fabrication & Erection of RCC Pole of Size 2.40 x 0.15 x 0.15 m including Centering, Concreting, Fabrication of Reinforcement etc. Complete as per Instruction of Departmental Officers - Rate For One Pole
322
-
-
Supplying and fixing barbed wire fencing to the Angle fencing post vertically and horiziontally as shownin the plan using of GI binding wire for tying the barbed wire has directed at site (The rates include cost of barbed wire and binding wire)
1606
-
-
Supplying and fixing for chain link fencing 1 Rm 2'x2'' using 10 gzuge galvanised iron wire etc., complete for foundation etc., complying with standard specification.
1445
-
-
Providing Pre construction of Anti termite Treatment for the Construction of building including all chemicals as per standard specifications. Labour charges for preparing the areas for treatment, spraying chemicals and other incident charges etc.,complete. The rate shall be inclusive of giving anti termite treatment to the building for the following four stages including breaking the termite moulds, making holes with crow bars at an interval of 30 cms to a depth of 50 cms in the pheriphery of building and pouring chemicals etc., complete as per ISI 6313 ( Part 2) 2001. The antitermite chemical chloropyriphos 20 EC used should form 0.5% concentrate for the entire operation etc., as directed by the Engineer in charge and including cost of chemicals labour transportation etc.,complete
1883
-
-
Stage 1: Spraying Anti termite treatment chemical solution for the foundation before laying the foundation concrete at bottom and sides of the foundation.
-
-
-
Stage 2: Spraying Anti termite treatment chemical solution to the grade beam level, spraying has to be done for the grade beam, brick masonry in the super structure in contact with back fill earth.
-
-
-
Stage 3: Spraying Anti termite treatment chemical solution on sand for the flooring before laying the flooring concrete; the treatment has to be carried out on the sand filling in basement and after leveling operation is over.
-
-
-
Stage 4: Spraying Anti termite treatment chemical solution around the building on outside by making crow bar holes at an interval of 15 cms to a depth of 30 cms before laying the plinth projection. These holes have to be closed after the treatment.
-
-
-
Supplying and fixing in positon Indian Water Closet (Oriya type) of size 580 x 440mm white glazed earthern ware of approved quality and brand with "P" or "S" trap conforming to BIS with sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One lime, Two sand and Five brick jelly) 100mm thick and finishing the top to the required slope and including giving necessary connection to CI soil pipes (including the cost of 100mm dia CI pipe for a length of 600mm) by dismantling brick masonry wall / reinforced cement concrete roof / floor slab and making good the dismantled portion to the original condition with leakages etc., complete complying with standard specifications and as directed by the departmental officers. (The water closet should be got approved by the Executive Engineer before use on works).
6
-
-
Supplying and fixing in position best quality and approved make Indian made white / colour glazed earthernware wash hand basin of size 550 x 400mm (with pedestal / without pedestal) with a pair of cast iron brackets, including cost 15mm dia brass CP pillar tap, 32mm dia "B" class GI waste pipe with rubber plug and chain, 15mm dia GM wheel valve, 15mm brass nipple, 15mm dia nylone connection, 32mm dia CP brass waste coupling including fixing of wash basin using CI brackets on to the wall in position with TW plugs and screws, rubber washers, white lead and giving necessary water supply connection and painting the brackets with two coat of painting over a priming coat of anti-corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the departmental officers. (The wash hand basin and specials should be got approved by the Executive Engineer before use on works).
2
-
-
Supplying and fixing PVC ventilating shaft of 110mm dia (having working pressure 4 kg. / sq.cm) with 3 metre height including cost of PVC cylindrical cowl of best approved quality etc., complete complying with standard specifications and as directed by the departmental officers
1
-
-
Supplying and fixing in position CI manhole covers with CI frames (Heavy duty) of size 60cm x 60cm of best approved quality as per standard specification etc., complete compying with standard specifications.
1
-
-
Construction of inspection chamber of size 60 cm x 60 cm x 60 cm with 75mm thick RCC loose slabs covering in C.M. 1:2:4 mix including necessary reinforcement and earth work excavation for foundation wth 23 cm thick concrete bed using 40mm B.J. concrete in CC 1:4:10 for foundation brick work in CM 1:6 for chamber as directed during the execution including plastering with CM 1:3, 12mm thick, benching and channelly etc complete for 1 No.
5
-
-
Supplying and fixing position CI Nahani Trap / Floor Trap of the following sizes with best stainless steel gratings of approved brand and quality, fixed over a bed of brick jelly lime concrete 1:2:5 (One part of lime, two part of sand and five part of 40mm gauge brick jelly) and finished with Cement Mortar 1:3 (One Cement, Three sand) including dismantling masonry works wherever found necessary and making good the dismantled portions to the original condition and giving connection to the CI / PVC pipes, etc., complete complying with standard specification. (The Nahani Trap should be got approved by the Executive Engineer before use on works)
-
-
-
a) Nahani Trap of size 100 x 75mm with stainless steel gratings
4
-
-
Supplying, laying and jointing PVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing PVC specials using PVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges, etc., complete complying with standard specifications. The PVC pipes shall be got approved by Executive Engineer before use on works.
-
-
-
a) For laying PVC pipes of dia 20mm.
6
-
-
b) For laying PVC pipes of dia 25mm.
25
-
-
c) For laying PVC pipes of dia 32mm.
30
-
-
Supplying and fixing in position first quality and approved variety of Gun metal Gate Valve / Wheel Valve with BIS make of the following dia including cost of shellac, thread balls, etc., complete complying with standard specifications (for both internal and external water supply arrangements). The valves to be used on work shall be got approved by the Executive Engineer before use on work.
-
-
-
a) Fixing Gun Metal Gate Valve of dia 25mm
1
-
-
b) Fixing Gun Metal Gate Valve of dia 32mm
1
-
-
Supplying and fixing in position 15mm dia brass CP screw down tap / Pillar tap (heavy duty) of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary. (Taps should be got approved by the Executive Engineer before use on the works)
10
-
-
Supplying and fixing in position Indian make bevelled edge mirror of approved quality and brand PVC / Fibre Glass framed 500 x 400 x 5.5mm thick mirror, shelf type with hard board backing of approved colour fixed with brass screws, rawl plug, etc., complete complying with standard specification. (The mirror should be got approved by the Executive Engineer before use on woks)
2
-
-
Supplying and fixing approved best quality brass CP towel rail 600mm long and 20mm dia with brackets of same materials including cost of teak wood plugs and CP screws, etc., complete complying with standard specifications. (The tower rail should be got approved by Executive Engineer before use on works).
4
-
-
Supplying and fixing best approved best quality brass CP soap tray of size 150 x 150mm including cost of teak wood plugs, brass screws, etc., complete complying with standard specifications. (The soap tray should be got approved by Executive Engineer before use on works).
2
-
-
Supplying, laying and jointing glazed stone ware pipes of the following dia of approved quality with spigot and socket ends and fixing them in dry condition using spun yarn and cement including petty masonry shoring and strutting wherever found necessary and laying the pipe line in the alignment at the specified gradient and testing with necessary tools and plants, etc., and re-filling the trench with excavated earth and levelling the ground etc., complete complying with standard specifications. (Earth work excavation, re-filling with excavated earth will be measured and paid separately).
-
-
-
b) 150mm dia stoneware pipe (cement joint)
30
-
-
Wiring with 2 x 1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor cable of 1100V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories and with TW switch box and 5A FT switch with painting of suitable colour with continuous earth wire connection of 1.5 sq.mm copper wire for open PVC light point / fan point (for electronic regulator) - SD 16
212
-
-
Wiring with 2 x 1.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories with 150mm x 100mm x 113mm TW switch box in flush with wall with 3mm thick hylem sheet cover for 5A 3 pin non inter locking wall socket with 5A flush type switch with painting of suitable colour with continuous earth wire connection of 1.5 sq.mm copper wire for open PVC plug point.-S.D 37
44
-
-
Wiring with 2 x 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor cable of 1100V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories with 150mm x 100mm x 113mm TW switch box in flush with wall with 3mm thick hylem sheet cover for 15A 3 pin flush type non inter locking wall socket with 15A flush type switch with painting of suitable colour with continuous earth wire connection of 4 sq.mm copper wire for open PVC power plug point SD:41
44
-
-
Supply and run of 2 of 6 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection of 6 sq.mm copper wire with painting of suitable colour. SD:58
325
-
-
Supply and fixing of horizontal type 4 way triple pole neutral MCB distribution board in sheet steel enclosure double door (metal) with 40A 4 pole MCB isolater as incoming and 12 Nos. 6A to 32A SP MCB as outgoing in flush with wall and making good of the concealed portion with earth connection. The MCBDB and MCB's should be with the ISI mark (like standard make).SD:-157
17
-
-
Supply and run of 4 x 6 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in 32mm dia GI pipe (Class 'B') suitably bent at both ends with necessary angle iron up right and end supports for mains. ( SD . 73 )
12
-
-
Supply and run of 4 x 6 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V on 7 / 20 GI bearer wire for service connection mains . ( SD .68)
332
-
-
Supply and fixng of TNEB meter board suitable for 3 phase 63A service connection made up of suitable angle iron frame work of size 2 feet x 1-1/2 feet using angle iron of size 1-1/2" x 1-1/2" x 1/4" rigidly fixed on wall covered with hylem sheet of size 2 feet x 1/2 feet of 6mm thickness with necessary bolts and nuts supports and supply and fixing of 3 Nos. 63A fuse units (500V), 1 No. neutral link, copper earth flat of size 1" x 1/4" with inter connection of EB meter to fuse units by 16 Sq.mm PVC insulated copper wire with 1 No 63 Amp 30 MA Four Pole RCD / RCCB (Higher End) with suitable necessary connection with earth connection complete. ( SD. 131 )
2
-
-
Supply and laying of 2 x 16 sq.mm. PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 metre layer of sand and covering the cable completely with bricks and sand and refilling the earth tomake good. (SD.177)
90
-
-
Supply and fixing of 48W LED street light fitting with LED (Higher end) with 32mm dia. GI pipe (class B) with 1 no.32 mm GI bend complete on the existing post/ on wall with PVC unsheathed copper leads with MS clamps and with painting SD 448
29
-
-
Supply and fixing of 4'40W single industrial type fluorescent fitting complete with copper choke and condensor with conduit pipe suspension from the ceiling with PVC unsheathed FRLS copper leads from the terminals to the fitting with fluorescent Tube. SD 92
151
-
-
Supply and fixing of 1200mm (48") sweep AC ceiling fan complete with stepped electronic 300W regulator with 1 metre down rod with fan clamp with side plates and cross arm of size 450mm (18") SD - 106
15
-
-
Earthing as per the ISI specification with an earth electrode of 2.10 metre Class 'B' GI pipe of dia not less than 40mm with copper earth plate of size 125mm x 50mm x 6mm with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry . (SD 211)
3
-
-
Supply and run of 1 of No.8 SWG GI wire for earth connection. ( SD 74 )
20
-
-
Supply and fixing of fancy glass shade and 15 W LED Bulb SD - 80
8
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%