Southern Railway Tender

... More
The SR has issued a formal invitation for competitive bids for the Southern Railway project, for Provision Of Electrically Operated Lifting Barrier's And Emergency Sliding Boom's At Interlocked Lc Gates (36 Nos) In Mdu-ten Section in Madurai, Tamil Nadu, with an estimated contract value of Rs. 5,38,36,268. The bid opening date for this tender is 06-06-2025 and the last date for bid submission is 28-06-2025. Interested bidders for Southern Railway tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.

Southern Railway - SR Tender

Works
Civil And Construction
Excavation
Ireps
Opening Date6 Jun 2025
Closing Date28 Jun 2025
Tender Amount₹ 5,38,36,268.09 
Notes
Download

AI Insights

Bid Capacity
... View More
The formula for bid capacity is V/N or 'V' whichever is less, where V is the advertised value of the tender in crores of Rupees and N is the number of years prescribed for completion of work for which bids have been invited.
Technical Capacity
... View More
The bidder must have successfully completed or substantially completed any one of the following categories of work(s) during the last 7 years: (i) Three similar works each costing not less than 30% of the advertised value of the tender, (ii) Two similar works each costing not less than 40% of the advertised value of the tender, or (iii) One similar work costing not less than 60% of the advertised value of the tender. A similar work includes signal interlocking works involving various systems such as EI or RRI or PI or IBS or IBH or LC gate or yard modification or UFSBI or Track circuit (AFTC or DC TC) or Axle Counter (SSDAC or MSDAC or HA-SSDAC) or Automatic signalling.

Costs

Summary

Provision Of Electrically Operated Lifting Barrier's And Emergency Sliding Boom's At Interlocked Lc Gates (36 Nos) In Mdu-ten Section

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
WOOD AND P.V.C. WORK // Providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws : // Providing and fixing factory made uPVC white colour fixed glazed windows/ventilators comprising of uPVC multi- chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), , uPVC extruded glazing beads of appropriate dimension, EPDM gasket, 24 G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. // Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 +/- 0.2 mm and single glazing bead of appropriate dimension. (Area upto 0.75 sqm.)

24

7249

173997.6

... More
Supply of QBCA1 - heavy duty contact relays with necessary inspection a s per specification/

144

6613

952380

... More
EARTH WORK // Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.

27

2161

58352.4

... More
Releasing o f point rods with rod roller trestles, complete assembly. This includes 24 releasing of all cranks, compensators and 'A' type concrete foundation on the rod run. The resultant pits are to be covered with earth and consolidated by ramming and levelling. a)Releasing of trestles 1/2 way

288

86

24854.4

... More
CONCRETE WORK // CEMENT CONCRETE (CAST IN SITU) // Providing and laying in 4 position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : // 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources: 6 graded stone aggregate 40 mm nominal size derived from natural sources)

20

6670

133405

... More
Supply, erection ,Testing & commissioning of 6 Way Double Door SPN DB consisting of 20/25 A,10kA, 30mA, 2P RCBO -1 No for incoming and 1P, 6/10/16/20/25/32 A, 10kA, 230V, 50Hz, MCB-4 Nos for outgoing . Cost including RCBO and MCBs etc.

6

5800

34800

... More
Provision of sliding boom arrangements (Working sheet attached)

-

-

1

... More
Installation, wiring and testing IPS as per RDSO Specification No. RDSO/SPN/165/2012 5 Version 3.0 or latest a) This work includes transporting the IPS from the stores by loading without any damages and installation of the same at site as required by railway engineer at site. b) Wiring of all modules, interconnections, proper earthing of equipments to the available earth and all other works connected for testing and commissioning of the same. c) Wiring all the output using wire PVC 7/1.4mm and 3/0.75mm copper with proper ladder arrangements and termination on terminal box as per approved wiring diagram. d) Provision of Teak wood terminal box with decolum cover with locking facility for 230V and field cable seperatively and painting particulars. e) Wiring of analog inputs for Datalogger.

15

38025

570375

... More
FLOORING // Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. // 40 mm thick with 20 mm nominal size stone aggregate

90

545

49050

... More
REINFORCED CEMENT CONCRETE // DESIGN MIX CONCRETE // Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing 5 strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in- charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. // All works upto plinth level // Concrete of M25 grade with minimum cement content of 330 kg /cum

26

8683

225778.8

... More
Supply and laying of 6 SWG GI wire

-

-

16

... More
MASONRY WORK // HALF BRICK MASONRY // Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.

48

86

4149.6

... More
Erection, testing and commissioning of Colour Light Signalling panel. ( Only CLS Panel will be supplied by Railways).

9

1100

9900

... More
Supply and termination and connection of LTUG cable of sizes of up to and including 50 6 sqmm size with single flange type brass cable gland aluminium tube terminal type crimping sockets. Note: One termination comprises of one number of single flange type brass cable gland and with four numbers of aluminium crimping sockets for all cores of the cable.

24

429

10313.04

... More
Laying o f signaling/power/ telecommunication cables a s p e r cable plan in cable trenches, masonry ducts, RCC Pipes, DWC pipes, GI Pipes etc.(Supply of cables is not included in this schedule).

42400

18

770832

... More
Excavation of pit, casting concrete foundation and erection of apparatus case full size as per Drg. No.SG/CN/02/6 and fixing of 2 Nos. of 'E' type locks, one for the front door and another for 8 the back door, fixing of one hard wood shelf plank 37mm thick and painting the apparatus case inside and outside with one coat of red-oxide and two coats of aluminium paints.(Supply of apparatus case is not included in this schedule).[Foundation bolts & nuts, 'E' type locks, cement, M sand, stone jelly of size 20/25 mm, hardwood plank of 37mm thick, paints, varnish, fixing bolts & nuts and a l l other miscellaneous materials required for thework shall be supplied by the Contractor.]

46

11333

521322.6

... More
Supply, fixing of metal sub control switch board of size 300X150X58 mm 1.6mm thick with 3 mm thick hylam decolam sheet, with 16A strip connector for Neutral and earth including all required accessories.

6

376

2257.2

... More
"Supply and installation of ASM panel, pre- wired(without Integrated power supply as per RDSO/SPN/165 o r latest). Necessary interface cable from IPS to ASM panel is not covered." c)Supply of Secondary cells - 2V-120AH capacity

140

4224

591360

... More
Dismantling and releasing of ground lever frame along with all connected gadgets like 23 lever locks, 'E' type locks, HP locks, etc., accounting and stacking them neatly at a place as instructed by Railway representative at site. The work also involves breaking and removal of concrete foundation and the resultant pit shall be filled and consolidated by ramming and levelling.

36

5550

199800

... More
DismantIng existing rifting barrier along with winch assembly and other components like boom, fringes, locking arrangements, pedestal, boom rest, locking rods/wires, pulley stakes, turn out wheels, 'A' base and other materials connected with functioning of rifting barrier, removing 6 engineering Indicators on track and level crossing road signages without any damage including demolishing concrete base of existing structures, filling, ramming and levelling the ground disturbed during demolition, clearing debris and stacking all released material in a neat and countable manner and clear of infringements, as directed. Note: Barriers on both sides of level crossing constitute one set.

36

24308

875110.68

... More
Supply and laying of RCC pipe of 150mm internal diameter and 25mm thick with suitable collar conforming to NP2 class as per IS No:458 including jointing using gunny bag and cement grouting

49

510

24990

... More
Supply ,Fixing, Testing and commissioning of one 5A three plate Ceiling rose / batern Lamp holder in the existing Round block with PVC batress including termination with required accessories.

72

35

2566.08

... More
Excavation of Cable trench across the concrete flooring / road / track as per specification

66

873

57618

... More
Supply, fixing of metal sub control switch board of size 150X100X58 mm 1.6mm thick with 3 mm thick hylam decolam sheet, with 16A strip connector for Neutral and earth including all required accessories.

6

430

2580

... More
Supply o f PBT terminals 25mm/ 60mm centre and PBT Fuse blocks with necessary inspection a s per specification/ drawing/ description enclosed in this document. a)Supply of PBT terminals 25mm centre.

5760

61

353894.4

... More
Installation of power equipments like battery chargers, transformers, transformer rectifiers, invertors, DC-DC convertors etc., in the apparatus cases and wiring the same using wire PVC 40 7/1.4mm and 3/0.75mm copper as per the approved wiring diagram and painting of particulars in the inside of the doors of the apparatus cases. The work also includes provision of protective arrangements i n bare terminals carrying high voltages. (Supply of power equipments is not included in this schedule).[Wire PVC 7/1.4mm and 3/0.75mm copper, protective arrangements, paint and all other miscellaneous materials required for the work shall be supplied by the Contractor].

10

1708

17080.1

... More
MASONRY WORK // Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : // Cement mortar 1:6 (1 cement : 6 coarse sand)

72

8288

596761.2

... More
Supply and provision of sealing compound for cable leading pipe for leading of cable of above 50 sqmm but up to and including 185sqmm

12

127

1524.84

... More
Supply of Relay, AC Immune, plug-in-type, Style 'QNA1', DC Neutral line, 24V, 8F.8B 36 contacts, front and back contacts metal to carbon, with plug board, retaining clip and connectors confirming to BRS:931A, IRS:S 60, IRS:S 34 and IRS:S 23 or latest. The interlocking code for this unit shall be ABDGH.

324

4639

1503045.72

... More
Supply, fixing , testing and commissioning of 25A single phase MCB Protected 3 pole industrial type Socket

6

1000

6000

... More
Supply o f PBT terminals 25mm/ 60mm centre and PBT Fuse blocks with necessary inspection as per specification/ drawing/ description enclosed in this document. c)Supply of PBT fuse block without ND fuse

180

103

18691.2

... More
WOOD AND P.V.C. WORK // ANODISED ALUMINIUM FITTINGS (ALL FITTINGS SHALL 22 BE ISI MARKED) // Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : // 100 mm

12

53

639

... More
Supply o f 2 4 Core x 1.5 Sq.mm PVC insulated Armoured, unscreened underground Railway Signalling copper cable as per IRS: S-63/2014 REV.4

6700

388

2600605

... More
Supply, fixing, testing, commissioning of 9W LED type bulk head fittings similar to PHILIPS model No FXC 101 with 9W LED lamp complete.

12

800

9600

... More
Supply o f Double walled corrugated pipe - 103.5mm inner dia & 120mm outer dia conforming to specification No. IS 14930(Part 2): 2001 with one coupler for every 6m o f pipe as per Technical specification

1612

365

588686.28

... More
Supply and Provision o f Earthing a s per RDSO Specification RDSO/SPN/197/2008 or latest (as per Technical Specification enclosed)

15

28118

421777.65

... More
Laying/Drawing and testing of LTUG Power cable of above 50 sqmm and up to and including 185 sq.mm size complete with accessories

1434

44

63985.08

... More
WOOD AND P.V.C. WORK // BRASS FITTINGS // Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.

6

723

4342.8

... More
EARTH WORK // Earth work in excavation by mechanical means (Hydraulic 1 excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. // All kinds of soil

112

205

23010.4

... More
Supply and provision of sealing compound for cable leading pipe for leading of power cables of upto and including 50sqmm size.

24

95

2281.44

... More
MASONRY WORK // Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: // Cement mortar 1:6 (1 cement : 6 coarse sand)

-

-

9

... More
Supply, fixing , testing and commissioning of switch and socket 6A-5Pin type including internal wiring in the existing control board.

24

84

2019.6

... More
REINFORCED CEMENT CONCRETE // STEEL REINFORCEMENT // Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. // Thermo-Mechanically Treated bars of grade Fe-500D or more.

3120

89

279708

... More
REINFORCED CEMENT CONCRETE // PRE-CAST RCC // Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete work in string courses, 16 bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but , excluding cost of reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).

1.5

9673

14510.25

... More
Laying of HDPE pipes of all sizes above 63mm Dia required couplers

-

-

14

... More
Provision of E type lock with key for fixing the same in LC/HP/FP Locks/SM slides

-

-

21

... More
Supply of GI pipes - 50mm dia -3.65mm thick as per Technical specification

-

-

5

... More
Installation and interface wiring of EOLB Control Panel Testing and commissioning 2 includes complete installation setup at the existing winch platform with necessary fixing arrangement and fully covering the cable upto the ground level below the platform, complete interface wiring from the EOLB panel with any alteration if required and fixing additional terminals if required except EOLB panel all other miscellaneous material required for that the work should be supplied by the contractor.

36

30000

1080000

... More
Releasing of hand plunger lock single/double along with switch extension pieces, stretcher bars, point/ trap indicators and other fixtures carefully without damaging the materials, accounting and stacking them neatly at a place as instructed by Railway representative at site.

36

2389

86014.08

... More
Manufacture and supply of M.S. relay frames of suitable size to hold up to 4/ 8/ 12/ 20 relays /plug in type as required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit and Point control circuits, fixing of plug boards, relays, resistors and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 12 6mm thick to IS specification 2036 - 1995 - Type F5, wiring and termination as per approved circuit diagram and painting the particulars.[Wire PVC copper, 3/0.75mm and 16/0.2mm copper, Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, for fixing resistors and condensers, MS flats 25mm x 6mm brass bolts and nuts, paints, soldering materials, resistors, condensers and all other miscellaneous materials required for the work shall be supplied by the contractor]. d)Wiring of Signal/ Point/ LC control circuit (up to 20 relays/Plug in type)

36

13597

489506.76

... More
REINFORCED CEMENT CONCRETE // DESIGN MIX CONCRETE // Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing 13 strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in- charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. // All works above plinth level upto floor V level // Concrete of M25 grade with minimum cement content of 330 kg /cum

24

10306

247348.8

... More
Fixing, testing and commissioning of Exhaust fan including wall opening fixing of frame and plastering as required for housing exhaust fan including wiring with 3CX1.0sqmm PVC insulated & sheathed copper flexible cable. (Exhaust fan will be supplied by Railways).

6

800

4800

... More
Laying/Drawing and testing of LTUG power cable of up to and including 50 sqmm size complete with required tools & accessories.

295

25

7439.9

... More
Provision of earth electrodes as per drawing No.SG/CN/02/13 and earthing of metallic sheath and armour of all cables in all apparatus cases, relay room, equipment room, SM's room for block and control, and earthing of all equipments in apparatus cases, power room, relay rack, cable termination rack, control panel, signals, lever frames with MS flat 35mm X 6mm/19c cable (MS flat for closer by areas and MS flat/19c cable combination for farther areas) as per the instructions of Railway representative at site. The work includes painting of earth resistance value on the earth pit. (Supply of 19C cable is not covered in the scope of this schedule). [MS flat for earthing 35mm X 6mm, cement, GI earth electrodes, common salt, charcoal, country bricks, M sand, soldering materials and all other miscellaneous materials required for the work shall be supplied by the Contractor].

242

1707

413227.1

... More
WOOD AND P.V.C. WORK // ANODISED ALUMINIUM FITTINGS (ALL FITTINGS SHALL BE ISI MARKED) // Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : // 100x10 mm

-

-

21

... More
FLOORING // VITRIFIED FLOOR TILES // Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% 28 and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. // Size of Tile 600x600 mm

102

1416

144498.3

... More
Fixing, testing and commissioning of BLDC Ceiling fan of 1200mm sweep with eletronic regulator. (BLDC ceiling fan with regulator will be supplied by Railways).

12

225

2700

... More
Excavation of trench in all kinds of soil including refilling as per specification

-

-

2

... More
Supply, erection and testing of earthing arrangements to drawing No: CEE/CN/MS/16- 2004

18

5706

102708

... More
Supply and fixing of medium duty GI pipe of 50 mm dia, conforming to IS.1239,part 1 (2004) ,for cable leading without clamp.

36

912

32859.72

... More
Fixing o f EKT instrument with (or) without crank handle o r o n suitable fixtures at station/apparatus case, provision of economiser push switch with locking facility, wiring with wire PVC 17 16/0.2mm copper, provision of teakwood terminal box covered with decolum along with locking facility and painting.(Supply of electric key transmitter and crank handles i s not covered in this schedule). [wire PVC 16/0.2mm copper, wire wound resistance, decolum covered terminal box with locking facility b y us ing 2 5 m m thick teakwood, bo lts a n d nuts , paints, push switches, padlocks a n d other miscellaneous materials required for this work shall be supplied by the contractor].

36

5445

196053.84

... More
Provision of GI pipes (50/100mm dia) for cable laying with offset at both ends and with couplings over RCC bridges, drainage, culverts, and girder bridges. For RCC bridges, drainage, and culverts, the pipes shall be mounted on concrete masonry supports of size 300mm x 300mm x 300mm at an interval of 2 meters. For girder bridges, the pipes shall be fixed on suitable MS clamps at an 6 interval of 2 meters. The ends of the pipes shall be closed with brick masonry abutments to ensure that no cable is exposed. The work shall be carried out as per the instructions of the Railway representative at the site.(Supply of GI pipes with couplings and laying of cables is not included in this schedule).Stone jelly (20/25mm size), bricks, sand, cement, MS angles, flats, bolts, nuts for manufacturing and fixing clamps, bricks, M sand, cement, and other miscellaneous materials for the work shall be supplied by the contractor.

1020

208

212710.8

... More
REINFORCED CEMENT CONCRETE // FORM WORK // Centering and shuttering including strutting, propping etc. and removal of form for // Suspended floors, roofs, landings, balconies and access platform

170

766

130313.5

... More
Fixing , testing and commissioning of self ballasted 18W to 20W,Minimum 100 Lumens/Watt, 230V, 1200mm Length with Box type fitting..

24

139

3336

... More
Supply and commissioning of SMPS Based integrated power supply system suitable for 4 interlocked LC gate In RE/Non RE area with VRLA Batteries conforming to RDSO Drawing No. SDO/IPS/LC/007 Drawing No. SDO/IPS/LC/007as RDSO specification no. RDSO/SPEC/165/2012 ver 3.0 or latest, it includes ELB 24VDC Hand generator 12-40V/10A module or ELB 110V AC/DC Hand generator module. Inspection RDSO

15

946968

14204533.2

... More
Excavation of trench to a depth of 1 Mtr. for track crossing of cables, refilling of trench by ramming and consolidating it as per the instructions of Railway representative at site after laying of 30 DWC/RCC pipes. During excavation of trench, it has to be ensured that the excavated soil does not mix with the ballast available. The depth o f 1 m trench shall b e from the bottom o f sleepers for track crossings. Laying of cables and DWC pipes is not included in this schedule. (Supply of DWC/RCC pipes with couplers/collars is not included in this schedule).

216

385

83257.2

... More
WOOD AND P.V.C. WORK // ANODISED ALUMINIUM FITTINGS (ALL FITTINGS SHALL 23 BE ISI MARKED) // Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. // Twin rubber stopper

6

62

373.5

... More
Excavation of trench to a depth of 1 Mtr. for road crossing of cables, laying of DWC/ 31 RCC pipes with collar/ coupling, refilling of trench by ramming and consolidating it and resurfacing it to the original position. Laying of cables is not included in this schedule. (Supply of DWC/RCC pipes with couplers/collars is not included in this schedule).

216

501

108222.48

... More
Supply, Erection, testing and commissioning of LV Box, made up of CRCA Sheet , powder coated housing with 2 numbers of 63A Rewirable porcelin Fuse base mounted on hylam sheet with locking arrangements complete.

6

3000

18000

... More
Supply and fixing of cable route indicator, cast iron plate type

-

-

1

... More
"Road crossing/ Track Crossing through Horizontal Drilling at approximately depth of 1.5 to 2m below the formation level of the earth including insertion of HDPE pipe/DWC pipe along with 33 couplers, drawl of cable (or) direct drawl o f cables etc. (Note: The pilot used for HDD should be of sufficient size to suit insertion of HDPE /DWC pipe of size 120mm (outer dia.) or direct drawl of three cables (Signalling/Power/Quad/OFC) or three nos.of 40mm dia HDPE pipe or any other combination as directed by the site engineer) ( Supply of HDPE pipe is not covered in this schedule)"

1180

1351

1594711

... More
Supply and fixing of PVC wiring conduit,rigid,25mm dia, 2mm wall thickness conforming to IS No:9537,part-III in concealed manner for electrical wiring in all kind of wall/roof etc., including all accessories.

300

71

21384

... More
"Submission of all relevent final 'As mades' of circuit diagrams, contact analysis charts, termination particulars of apparatus cases and cable termination rack, power supply arrangements, relay index board, cable plans, cable route plans, red boundary plans and all other particulars covered under various schedules. All 'As mades' shall be prepared by the Contractor in AUTOCAD 2000 or 27 latest and submitted in CDs. One copy of the 'As mades' check print shall be submitted before Testing the circuits. The final negatives shall be made in tracing sheet (80 to 90 gsm). All 'As mades' except cable plan, cable route plan, bonding diagram & power supply diagram shall be prepared in A3 size. On approval the contractor shall submit along with the negatives, 8 copies in each, duly making booklet neatly bound. Out of 8 sets, 2 sets of drawings and other plans shall be kept in transparent plastic cover (2 sheets back to back in one plastic cover) and handed over to Railways. Also the contractor has to supply one set of As mades in 'Reproduction Film'. The approved circuit diagram will be issued by Railways in soft copy as well as two sets of hard copies. Wherever alterations to existing circuits are involved, the existing as-made circuit diagrams will be supplied by Railways either in CDs or RP film. The Contractor shall incoporate the details of all the new wirings and alterations in the CD/ RP film and submit them to Railways. Onapproval 8 copies shall be made for As-made circuit diagrams also as mentioned above"

620

382

236914.4

... More
Supply of E-Type Locks

-

-

20

... More
REINFORCED CEMENT CONCRETE // FORM WORK // Weather shade, Chajjas, corbels etc., including edges

3

814

2444.85

... More
REINFORCED CEMENT CONCRETE // FORM WORK // Centering and shuttering including strutting, propping etc. and removal of form for // Lintels, beams, plinth beams, girders, bressumers and cantilevers

172

608

104636.2

... More
Supply, fixing of metal sub control switch board of size 200X150X58 mm 1.6mm thick with 3 mm thick hylam decolam sheet, with 16A strip connector for Neutral and earth including all required accessories.

12

570

6840

... More
REINFORCED CEMENT CONCRETE // FORM WORK // Centering and shuttering including strutting, propping etc. and removal of form for // Foundations, footings, bases of columns, etc. for mass concrete

18

307

5543.1

... More
WOOD AND P.V.C. WORK // MISCELLANEOUS-WOOD WORK // Providing and fixing 26 M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. // Fixed to openings /wooden frames with rawl plugs screws etc.

480

197

94896

... More
REINFORCED CEMENT CONCRETE // STEEL REINFORCEMENT // Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. // Thermo-Mechanically Treated bars of grade Fe-500D or more.

4800

89

430320

... More
Fabrication, supply and fixing of clamps made out MS flats of different sizes for fabrication of clamps for various requirements. This shall be made use for fixing of items indicated in 12 the note below. The clamp shall be made out of MS flat of suitable size, painted with two coats in each of zinc chromate and grey enamel paint or suitable colour as instructed by the Engineer in charge and using GI bolts with nuts of suitable size for fixing. Note: This shall be made use for fixing of items such as UG cables, cable leading pipe,'U' brackets for shelter mains, enclosures made out of 16 SWG sheet steel contemplated elsewhere and cable tray etc.

18

131

2374.56

... More
Laying of HDPE pipes of sizes upto and including 63mm dia with required couplers

-

-

13

... More
Supply, fixing, Testing and commissioning of 5 A light switch / Fan switch / calling bell switch model similar to Anchor make Penta PC in the existing hylam sheet on sub control switch board including termination with required accessories.

72

41

2993.76

... More
"Supply o f 2x25 sqmm PVC insulated Armoured, unscreened underground Railway Signalling Aluminium cable as per IRS: S- 63/2014 REV.4"

7500

93

697575

... More
WOOD AND P.V.C. WORK // Providing and fixing panelled or panelled and glazed 18 shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) // Second class teak wood // 35 mm thick shutters

12

3704

44453.4

... More
Supply and wiring including termination by 3 No's of 1.5 sq.mm PVC insulated flexible copper cables confirming IS No. 694,1100V grade through the existing PVC pipe already laid.

480

74

35923.2

... More
ROOFING // SHEET ROOFING // Providing and laying pressed clay tiles (as per 33 approved pattern 20 mm nominal thickness of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 coarse sand) mixed with 2% integral water proofing compound, laid over a bed of 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and finished neat complete.

132

620

81840

... More
WOOD AND P.V.C. WORK // Providing and fixing panelled or panelled and glazed 25 shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) // Float glass panes // 5.0 mm thick glass panes (weight not less than 12.50 kg/sqm).

24

2231

53548.8

... More
Placing of one row of country bricks of size approximately 220mm x 100mm x 60mm breadth wise horizontally above the cables in 0.3m width trench.[Country bricks of size 220mm x 100mm x60 mm (approximately) shall be supplied by the Contractor].

13200

62

831468

... More
Supply of apparatus cases (full/ half/ quarter size) to suit Southern Railway standard with necessary inspection a s p e r specification/ drawing/ description enclosed i n this document a)Supply of apparatus case - Full size

46

18821

865766

... More
Supply o f 12Cx1.5 SQMM PVC insulated Armoured, unscreened underground Railway Signalling copper cable as per IRS: S-63/2014 REV.4

28200

215

6088944

... More
Transportation o f Signalling materials by road a s p e r t h e instructions o f Railway representative at site. The work also includes loading and unloading of the materials a)Transportation of Signalling materials upto 100kms

1800

22

40950

... More
"Supply of Self Regulating Battery Charger 230V AC/24V DC, 30A (signalling) shall be suitable for axle counter as per RDSO spec no.lRS S : 86/2000 with amendment 4 or latest."

10

64414

644140.9

... More
WOOD AND P.V.C. WORK // FRAMES AND TRUSSES // Providing wood work in frames 17 of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). // Second class teak wood

0.45

-

59209.63

... More
FINISHING // CEMENT PLASTER (IN FINE SAND) // 12 mm cement plaster of mix : // 1:6 (1 cement: 6 fine sand)

312

282

87984

... More
Supply, fixing , testing and commissioning of switch and socket 6A/16A - 5Pin type including internal wiring in the existing control board.

12

275

3300

... More
MASONRY WORK // HALF BRICK MASONRY // Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. // Cement mortar 1:4 (1 cement :4 coarse sand)

48

1018

48866.4

... More
Supply o f PBT terminals 25mm/ 60mm centre and PBT Fuse blocks with necessary inspection a s per specification/ drawing/ description enclosed in this document. b)Supply of PBT terminals 60mm centre.

432

93

40184.64

... More
Supply and fixing of medium duty GI pipe of 65 mm dia, conforming to IS.1239,part 1 (2004) ,for cable leading without clamp.

36

1175

42323.04

... More
FINISHING // CEMENT PLASTER (IN FINE SAND) // 20 mm cement plaster of mix : // 1:6 (1 cement: 6 fine sand)

570

382

217797

... More
REINFORCED CEMENT CONCRETE // FORM WORK // Centering and shuttering including strutting, propping etc. and removal of form for // Columns, Pillars, Piers, Abutments, Posts and Struts

120

804

96510

... More
FINISHING // EXTERIOR FINISHING // Finishing walls with Acrylic Smooth exterior paint of required shade : // New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

-

-

32

... More
Fabrication, supply, fixing and commissioning of outdoor metallic box of single door size 400X300X200 mm made of 14 SWG sheet steel with hinges for opening at LCs and stations. The looping box shall consist of 100A, 4-way terminal connectors fixed on hylam sheet of 200X200X6 mm 21 thickness and its proper cable looping/ terminal connections. The box shall have back clamps of suitable size and sufficient numbers of 70 Sq mm cable glands with all accessories. The loop box as well as clamps should be painted with two coats of red oxide and two coats of aluminium/ grey metallic paint. This includes fixing of the box on wall/ structure with suitable mounting / rag/ anchor bolts.

6

4000

24000

... More
EARTH WORK // Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.

57

253

14475.15

... More
Excavation of cable trench in all kinds of soil except hard rocky areas including clearing of roots of trees, rocks, bushes etc. to a depth of 1.0 Mtrs and to a width of 0.3 Mtrs. (Laying of cables is not included in this schedule)

13200

64

846120

... More
FINISHING // Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : // Two or more coats on new work

22.68

131

2981.29

... More
Supply and wiring including termination by 3 No's of 2.5 sq.mm PVC insulated flexible copper cables confirming IS No. 694,1100V grade through the existing PVC pipe already laid.

240

106

25660.8

... More
"Refilling of cable trench 1m depth by 0.3m width throughout, with earth after laying of cables, and consolidating the trench by ramming and levelling."

13200

15

203280

... More
Transportation of Signalling materials more than 100km

-

-

26

... More
Supply and fixing of PVC wiring conduit,rigid,25mm dia, 2mm wall thickness conforming to IS No:9537,part-III in Open manner for electrical wiring in all kind of wall/roof etc., including all accessories.

90

49

4490.1

... More
Supply of KLCR relays 24V, ACI (Supply of Key Lock Checking Relay (KLCR) with one 16 number K-50 neutral Relay to work on 24V DC n o n A C immunized a s p e r specification No.RDSO/SPN/219/2016 Ver 1.0 with Amdt- 1 o r latest (with one extra ward plate and with case) contact configuration-4F/4B and as per IRS:S-23, IRS:S@ 58"44@ IRS:46 or latest.

36

10722

386017.92



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.