The SR has issued a formal invitation for competitive bids for the Southern Railway project, for Electrical Arrangements For :1) Basin Bridge Junction-additional Trip Shed At Bbq With Two Pitlines And Service Buildings 2) Construction Of 2 No.s Of Gang Rest Rooms At Sse/p.way/tiruvotriyur Section In Aden/east/mas Sub-division 3) Chennai Division:den/east's Jurisdiction -elimination Of Deficiencies In Mea At 18 Stations (nsg 6- 6 Stations,sg3-12 Stations) 4) Ajj-jtj Section-replacement Of Fob No.273(existing) At Walajah Road(km 104/786) 5) Ajj-jtj Section-reconstruction Of Fob In View Of Dilapidated Fob No.460a In Gudiyatham Station in Chennai, Tamil Nadu, with an estimated contract value of Rs. 26,16,546. The bid opening date for this tender is 16-05-2025 and the last date for bid submission is 09-06-2025. Interested bidders for Southern Railway tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.

Southern Railway - SR Tender

Works
Civil And Construction
Excavation
Ireps
+1Tirupathur, Tamil Nadu
Opening Date16 May 2025
Closing Soon9 Jun 2025
Tender Amount₹ 26,16,546 
Notes
Download

Costs

Summary

Electrical Arrangements For :1) Basin Bridge Junction-additional Trip Shed At Bbq With Two Pitlines And Service Buildings 2) Construction Of 2 No.s Of Gang Rest Rooms At Sse/p.way/tiruvotriyur Section In Aden/east/mas Sub-division 3) Chennai Division:den/east's Jurisdiction -elimination Of Deficiencies In Mea At 18 Stations (nsg 6- 6 Stations,sg3-12 Stations) 4) Ajj-jtj Section-replacement Of Fob No.273(existing) At Walajah Road(km 104/786) 5) Ajj-jtj Section-reconstruction Of Fob In View Of Dilapidated Fob No.460a In Gudiyatham Station

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Installation,Testing and Commissioning of the Maintenance free LT Earthing arrangements duly by excavating/ auguring of earth pit in all kinds of soil/concrete surface or 10 elsewhere, construction of masonry earth pit enclosure, provision of cover etc.,complete including supply / leading / laying / burying and concealing of 4 SWG GI wire from earth electrode to proposed MDB / SDB or elsewhere and in a manner as directed by Senior Section Engineer in charge at site. Note: 1) Masonry earth pit enclosure and cover shall be as per drawing number EL/P/TYPE/1022. 2)

2

1900

3800

... More
Drawing of inside mains using 2 runs of 4 sq. mm [from MCB DB to switch boards and 34 from switch boards to switch boards / modular furniture or elsewhere] fire retardant Low smoke PVC insulated unsheathed multi-stranded copper conductor cables duly inside the PVC conduit concealed / laid vide item No. 38 below complete as per the specification enclosed and in a manner as directed by Senior Section Engineer in charge at site. Note: - 2 runs of 4 sq. mm copper conductor are taken

580

13

7540

... More
Installation,Testing and commissioning of SMC box assembly similar to Sintex Catalogue reference No.GSJB-1414 along with strip connector block,Neutral link,fuse bases and carriers onto lamp posts or elsewhere suing suitable clamping arrangements complete and in a

70

128

8960

... More
Installation,Testing and commissioning of modular frame plate with matching cover plate including and suitable for 6 modules, switches, sockets, blank plates etc. and 1 No SP modular type Miniature Circuit Breaker duly accommodated onto suitable modular switch board box complete and recess mounting/ concealing the same onto the wall using suitable fixing arrangements including cutting/ chipping/ making recess on the wall or elsewhere including replastering, painting the walls back to original condition etc complete as per industrial standards and in a manner as directed by Senior Section Engineer in charge at site. Note: -Frame plate with matching cover plate, SP modular

-

-

42

... More
Installation,Testing and commissioning of modular frame plate with matching cover plate including and suitable for 4 modules, switches, sockets, blank plates etc. duly accommodated 43 onto suitable modular switch board box complete and recess mounting/ concealing the same onto the wall using suitable fixing arrangements including cutting/ chipping/ making recess on the wall or elsewhere including replastering, painting the walls back to original condition etc complete as per industrial standards and in a manner as directed by Senior Section Engineer in charge at site. Note: - Frame plate with matching cover plate, switch, socket and Modular GI box alone will be Supplied

16

95

1520

... More
Installation,Testing and commissioning of of 32A, SP MCB with Enclosure onto wall or elsewhere using suitable angle iron frame work and mounting and fixing arrangements as per industrial standards complete in a manner as directed by Section Engineer in charge at site. Note:

-

-

13

... More
Drawing of inside mains using 2 runs of 1.5 sq. mm [from MCB DB to switch boards 36 and from switch boards to switch boards / modular furniture or elsewhere] fire retardant Low smoke PVC insulated unsheathed multi-stranded copper conductor cables duly inside the PVC conduit concealed / laid vide item No. 38 below complete as per the specification enclosed and in a manner as directed by Senior Section Engineer in charge at site. Note: - 2 runs of 1.5 sq. mm copper

2150

13

27950

... More
Supply and provision of MS brackets, fabricated as per sketch enclosed, for supporting 50 OH wire beneath platform shelters, mounted with 4 Nos. of porcelain vertical reel / shackle insulators and earth stud / bolt, finished with 2 coats of red primer and 1 coat of aluminium paint and complete with fixing arrangements as per drawing enclosed and in a manner as directed by Section Engineer in charges at site.

10

466

4660

... More
Wiring to light, fan, exhaust fan points [Medium point i.e. length between 3 to 6 mtr] by supply and drawing of 2 runs of 1.5 sq. mm Fire Retardant Low Smoke PVC insulated copper multi- 23 stranded copper cables of 1100 V grade [conforming to IS: 694/1990 or latest] duly inside the PVC conduit concealed vide item No. 38 below complete with provision of 6 A flush type switch conforming to IS: 3854/1997 or latest, 1 No. 3 plate ceiling rose conforming to IS: 371/1999 or latest and with all standard accessories complete and in a manner as directed by Section Engineer in

173

290

50170

... More
Laying/leading of 4 core 35 sq.mm LTUG cable in the excavated trench, threading through pipe, clamping on walls and terminating in as many ends using suitable single compression cable glands and sockets complete in a manner as directed by Section Engineer in charge at site.

1100

30

33000

... More
Installation,Testing and commissioning of of time switch assembly comprising of: - a)1 No. timer switch with daily setting similar to L&T catalogue reference J648B1 [FM1 Quartz]. b)1 No. 3 pole 25A power contactor conforming to IS: 13947/P4/1993 or latest, c)1 No. 40A DP [MCB type] isolator conforming to IS: 13947/P3/1993 or latest, d)1 No. Neutral link etc. e)1 No. Earth link etc. f) 15 Suitable rated control fuses all duly pre-wired and mounted on an appropriate sized well-seasoned wooden plank of thickness not less than 12 mm and duly housed into and powder coat finished enclosure of size not less than 300mm X 450mm X 300mm and made of 2mm thick Sheet Steel complete and provision of the same onto the wall or elsewhere using suitable fixing arrangements complete and in a manner as directed by Section Engineer in charge at site. Note:Timerswitch,Power contactor,MCB,Neutral Link,Earth link,fuses,wooden box,enclosures alone will be supplied

12

570

6840

... More
Drawing of inside mains using 2 runs of 2.5 sq. mm [from MCB DB to switch boards 33 and from switch boards to switch boards / modular furniture or elsewhere] fire retardant Low smoke PVC insulated unsheathed multi-stranded copper conductor cables duly inside the PVC conduit concealed / laid vide item No. 38 below complete as per the specification enclosed and in a manner as directed by Senior Section Engineer in charge at site. Note: - 2 runs of 2.5 sq. mm copper

380

13

4940

... More
Installation, Testing and commissioning of 80W LED High Bay light fittings using 32 suitable mounting and fixing arrangements as per industrial standards including supply connection from ceiling rose by using 3 core 1.5 sq. mm Fire retardant low smoke PVC insulated, PVC round sheathed copper [White/Ivory colour] conductor flexible chord complete in a manner as directed by Section Engineer in charge at site. Note: 80W LED HighBay light fitting alone will be supplied

5

234

1170

... More
Installation, Testing and commissioning of metal junction box(switchboard of size 22 200mmx150mmx50mm fabricated with 16 gauge steel an provided with 3mm thick decolam sheettop, knockout, and recess mounting/ concealing the same onto the wall using suitable fixing arrangements including cutting/ chipping/ making recess on the wall or elsewhere including replastering painting etc., complete and in a manner as directed by Senior Section Engineer in charge

26

183

4758

... More
Laying/leading of 4 core 95 sq.mm LTUG cable in the excavated trench, threading through pipe, clamping on walls and terminating in as many ends using suitable single compression cable glands and sockets complete in a manner as directed by Section Engineer in charge at site.

250

52

13000

... More
Installation,Testing and commissioning of modular frame plate with matching cover plate including and suitable for 8 modules, switches, sockets, blank plates etc. and 1 No SP modular 41 type Miniature Circuit Breaker duly accommodated onto suitable modular switch board box complete and recess mounting/ concealing the same onto the wall using suitable fixing arrangements including cutting/ chipping/ making recess on the wall or elsewhere including replastering, painting the walls back to original condition etc complete as per industrial standards and in a manner as directed by Senior Section Engineer in charge at site. Note: -Frame plate with matching cover plate, SP modular

8

195

1560

... More
Installation,Testing and Commissioning of the LT Earthing arrangements duly by excavating/ auguring of earth pit in all kinds of soil/concrete surface or elsewhere, construction of 11 masonry earth pit enclosure, provision of cover etc.,complete including supply / leading / laying / burying and concealing of 4 SWG GI wire from earth electrode to proposed MDB / SDB or elsewhere and in a manner as directed by Senior Section Engineer in charge at site. Note: 1) Masonry earth pit enclosure and cover shall be as per drawing number EL/P/TYPE/1022. 2) LT Earthing arrangements

26

1180

30680

... More
Drawing of inside mains using 2 runs of 6 sq. mm [from MCB DB to switch boards and 35 from switch boards to switch boards / modular furniture or elsewhere] fire retardant Low smoke PVC insulated unsheathed multi-stranded copper conductor cables duly inside the PVC conduit concealed / laid vide item No. 38 below complete as per the specification enclosed and in a manner as directed by Senior Section Engineer in charge at site. Note: - 2 runs of 6 sq. mm copper conductor are taken

50

13

650

... More
Laying of 50 mm dia ISI Marked High Density Polyethylene pipes in the excavated trench, clamping on walls / Steel members of platform shelter or elsewhere using suitable fixing arrangement complete in a manner as directed by Senior Section Engineer-in-charge at site. Note: 50

6000

28

168000

... More
a)Excavation of Cable trench in all kinds of soils duly removing all obstructions in the 01 way of cable trench, dumping at embankment site within railway land complete as per specification enclosed and in a manner as directed by the Section Engineer in charge at site. NOTE: The Section Engineer, in charge at site, will indicate the route of cable trench. b)Re-filling of trench with excavated earth, ramming, consolidation and bringing back the surface to original condition complete

1391

249

346359

... More
Installation,Testing and commissioning of modular frame plate with matching cover plate including and suitable for 12 modules, switches, sockets, blank plates etc. and 1 No SP modular 40 type Miniature Circuit Breaker duly accommodated onto suitable modular switch board box complete and recess mounting/ concealing the same onto the wall using suitable fixing arrangements including cutting/ chipping/ making recess on the wall or elsewhere including replastering, painting the walls back to original condition etc complete as per industrial standards and in a manner as directed by Senior Section Engineer in charge at site. Note: -Frame plate with matching cover plate, SP modular

19

195

3705

... More
Installation, Testing and Commissioning including concealing work along with metal 30 clad plug and socket unit in sheet steel enclosure conforming to IS: 8623/1993 or latest complete as per industrial practices with 1 No. 20 A,SP, MCB onto the walls including cutting/chipping and replastering and bringing back walls to original condition including painting in a manner as directed by section engineer in charge at site. Note: Metal clad plug and socket with Enclosure and MCB alone

37

54

1998

... More
Installation,Testing and commissioning of the 400mm sweep BLDC Wall Mounting fan onto the buildings or elsewhere using suitable clamping and fixing arrangement complete as per industrial practices including supply connection from ceiling rose by using 3 core 1.5 sq. mm fire retardant Low smoke PVC insulated, PVC round sheathed copper [White / Ivory colour] conductor flexible pendant chord conforming to IS:694/1990 or latest complete as per industrial standards and in a manner as directed by Senior Section Engineer in charge at site. Note: 400mm sweep BLDC Wall

-

-

20

... More
Wiring to light, fan, exhaust fan points [Long point i.e. length between 6 to 9 mtr] by supply and drawing of 2 runs of 1.5 sq. mm Fire Retardant Low Smoke PVC insulated copper multi- 24 stranded copper cables of 1100 V grade [conforming to IS: 694/1990 or latest] duly inside the PVC conduit concealed vide item No. 38 below complete with provision of 6 A flush type switch conforming to IS: 3854/1997 or latest, 1 No. 3 plate ceiling rose conforming to IS: 371/1999 or latest and with all standard accessories complete and in a manner as directed by Section Engineer in

37

364

13468

... More
Supply and provision of mass concrete for platforms or elsewhere with 1:2:4 ratio using 20mm blue metal complete in a manner as directed by the Section Engineer in charge at site.

-

-

3

... More
Laying/leading of 4 core 16 sq.mm LTUG cable in the excavated trench, threading through pipe, clamping on walls and terminating in as many ends using suitable single compression cable glands and sockets complete in a manner as directed by Section Engineer in charge at site.

1200

28

33600

... More
Installation, testing and commissioning of 150mm width x 50mm height made of 2mm thick hot dip galvanized Sheet steel complete with all accessories including coupler plate, supports fabricated MS flats of sufficient thickness and same duly supported from walls/ceiling/roof 47 purloins/steel members of platform shelter/Foot over Bridge or elsewhere using intermediate supports of MS flats complete including carrying out all civil works incidental to provision/supporting/grouting of cable tray supports complete as per industrial standards and in a manner as directed by Section Engineerin- charge at site. Note: 1)The cable tray supports shall be applied with two coats of red oxide primer and finished with two coats of bright aluminium paint.

150

347

52050

... More
Installation,Testing and commissioning of 45 W LED street light fittings using suitable GI tubular mounting arm bent to act as tubular support for anchoring arrangement onto walls 25 including supply connection from ceiling rose/junction box or elsewhere by using 3 core 1.5 sq. mm Fire retardant low smoke PVC insulated, PVC round sheathed copper [White/Ivory colour] conductor flexible chord conforming to IS:694/1990 or latest as per industrial standards in a manner as directed by Section Engineer in charge at site. Note: 45W LED Street light fittings alone will be supplied

20

162

3240

... More
Installation,Testing and commissioning of 4 feet 20W LED light fitting suitable to work on 240V single phase 50 Hz AC with lamp and all standard accessories using suitable mounting and 18 fixing arrangement as per industrial practices including supply connection from ceiling rose by using 3 core 1.5 sq. mm Fire Retardant Low Smoke PVC insulated, PVC round sheathed copper [White/Ivory colour] conductor flexible pendant chord conforming to IS:694/1990 or latest complete as per industrial standards and in a manner as directed by Senior Section Engineer in charge at site. Note: 4

217

95

20615

... More
Installation,Testing and commissioning of 1200mm sweep BLDC ceiling fan onto the buildings or elsewhere using suitable clamping and fixing arrangement complete as per industrial 16 practices including supply connection from ceiling rose by using 3 core 1.5 sq. mm fire retardant Low smoke PVC insulated, PVC round sheathed copper [White / Ivory colour] conductor flexible pendant chord conforming to IS:694/1990 or latest complete as per industrial standards and in a manner as directed by Senior Section Engineer in charge at site. Note: 1200mm sweep BLDC Ceiling fan alone

31

216

6696

... More
Installation,Testing and commissioning of 4 feet 30W LED light fitting suitable to work on 240V single phase 50 Hz AC with lamp and all standard accessories using suitable mounting and 19 fixing arrangement as per industrial practices including supply connection from ceiling rose by using 3 core 1.5 sq. mm Fire Retardant Low Smoke PVC insulated, PVC round sheathed copper [White/Ivory colour] conductor flexible pendant chord conforming to IS:694/1990 or latest complete as per industrial standards and in a manner as directed by Senior Section Engineer in charge at site. Note: 4

50

95

4750

... More
Installation,Testing and commissioning of 70 W LED street light fittings using suitable GI tubular mounting arm bent to act as tubular support for anchoring arrangement onto walls 26 including supply connection from ceiling rose/junction box or elsewhere by using 3 core 1.5 sq. mm Fire retardant low smoke PVC insulated, PVC round sheathed copper [White/Ivory colour] conductor flexible chord conforming to IS:694/1990 or latest as per industrial standards in a manner as directed by Section Engineer in charge at site. Note: 70W LED Street light fittings alone will be supplied

4

234

936

... More
Installation, Testing and commissioning of TPN MCB DB's with MCCB's/RCBO's as Incomer along with combination of SP/DP/FP,MCB's as feeder controls along with Cable adaptor box 46 on to the wall using suitable angle iron frame work and including cutting/chipping and re-plastering and bringing back walls to original condition including painting the walls to original condition complete and as per industrial practices in a manner as directed by Senior Section Engineer in charge at site. Note: MCB DB, ,MCCB,MCB, RCBO, Cable adaptor box etc alone will be supplied

3

950

2850

... More
Stringing of over head mains beneath platform shelters using 5 runs of 35 sq. mm PVC 49 insulated and PVC sheathed multi stranded aluminium conductor cable duly by binding onto insulators of brackets provided vide item No. 50 below complete in a manner as directed by Section Engineer in charge at Site. Note: 5 runs of 35 sq.mm Aluminum cable are taken as 1m for unit

50

6

300

... More
Erection, testing and commissioning of 4 meter Double arm octagonal pole assembly 45 onto the suitable RCC foundation and coping by using modern engineering practice including installation,testing and commissioning of LED luminaries including all wiring works from nearby junction box as per industrial standards in a manner as directed by Section Engineer in charge at site. Note: 1) The foundation shall be as per the standard practice and as per the specification enclosed.

19

2798

53162

... More
Demolishing plain cement concrete in platform or elsewhere, disposal of material

-

-

2

... More
Installation,Testing and commissioning of 200 W LED Flood light fittings using suitable GI tubular mounting arm bent to act as tubular support for anchoring arrangement onto walls 29 including supply connection from ceiling rose/junction box or elsewhere by using 3 core 1.5 sq. mm Fire retardant low smoke PVC insulated, PVC round sheathed copper [White/Ivory colour] conductor flexible chord conforming to IS:694/1990 or latest as per industrial standards in a manner as directed by Section Engineer in charge at site. Note: 200W LED Flood light fittings alone will be supplied

5

234

1170

... More
Laying/leading of 4 core 25 sq.mm LTUG cable in the excavated trench, threading through pipe, clamping on walls and terminating in as many ends using suitable single compression cable glands and sockets complete in a manner as directed by Section Engineer in charge at site.

3950

28

110600

... More
Installation,Testing and commissioning of the 300mm sweep BLDC Exhaust fan onto the buildings or elsewhere using suitable clamping and fixing arrangement complete as per industrial 17 practices including supply connection from ceiling rose by using 3 core 1.5 sq. mm fire retardant Low smoke PVC insulated, PVC round sheathed copper [White / Ivory colour] conductor flexible pendant chord conforming to IS:694/1990 or latest complete as per industrial standards and in a manner as directed by Senior Section Engineer in charge at site. Note: 300mm sweep BLDC Exhaust fan alone

30

185

5550

... More
Laying of 110 mm dia ISI Marked High Density Polyethylene pipes in the excavated trench, clamping on walls / Steel members of platform shelter or elsewhere using suitable fixing arrangement complete in a manner as directed by Senior Section Engineer-in-charge at site. Note:

250

52

13000

... More
Installation,Testing and commissioning of 90 W LED street light fittings using suitable GI tubular mounting arm bent to act as tubular support for anchoring arrangement onto walls including supply connection from ceiling rose/junction box or elsewhere by using 3 core 1.5 sq. mm Fire retardant low smoke PVC insulated, PVC round sheathed copper [White/Ivory colour] conductor flexible chord conforming to IS:694/1990 or latest as per industrial standards in a manner as directed by Section Engineer in charge at site. Note: 90W LED Street light fittings alone will be supplied

-

-

27

... More
Installation,Testing and commissioning of 150 W LED Flood light fittings using suitable GI tubular mounting arm bent to act as tubular support for anchoring arrangement onto walls 28 including supply connection from ceiling rose/junction box or elsewhere by using 3 core 1.5 sq. mm Fire retardant low smoke PVC insulated, PVC round sheathed copper [White/Ivory colour] conductor flexible chord conforming to IS:694/1990 or latest as per industrial standards in a manner as directed by Section Engineer in charge at site. Note: 150W LED Flood light fittings alone will be supplied

4

234

936

... More
Installation, Testing and commissioning of Storage Drinking Water Cooler, 150 Litre 14 Capacity, Power factor 0.85, Stainless Steel Water Tank with PUF insulation, Eco Friendly Refrigerant, water tank cover GI sheet with Epoxy painted conforming to Is 1475 Latest into the gage using suitable fixing and mounting arrangements complete as per industrial standards using contactors men and materials including transportation in a manner complete as directed by Section Engineer in

25

2450

61250

... More
Concealing of 25mm dia rigid PVC conduits [IVORY colour] along with all accessories 38 and including cutting/ chipping the wall/ceiling or elsewhere and making good the same including replastering and painting wall to original condition /clamped at regular intervals, not exceeding 500 mm in a manner as directed by Section Engineer in charge at site and as per specification for wiring/ rewiring enclosed. [Approximate length of PVC conduit] Note:25 mm dia PVC conduit

3949

34

134266

... More
Installation,Testing and commissioning of 32A,30 kA, FP MCCB with Enclosure onto wall or elsewhere using suitable angle iron frame work and mounting and fixing arrangements as per industrial standards complete in a manner as directed by Section Engineer in charge at site. Note:

2

217

434

... More
Erection, testing and commissioning of 4 meter Single arm octagonal pole assembly 44 onto the suitable RCC foundation and coping by using modern engineering practice including installation, testing and commissioning of LED luminaries including all wiring works from nearby junction box as per industrial standards in a manner as directed by Section Engineer in charge at site. Note: 1) The foundation shall be as per the standard practice and as per the specification enclosed.

29

2798

81142

... More
Installation, Testing and commissioning of 600mm sweep BLDC Air circulators onto 31 wall / stanchion / rail post or elsewhere using suitable suitable clamping arrangement made of 40mm X 6mm MS flat and MS plate of size of 300mm X 300mm X 6mm complete in a manner as per standard industrial standards and in a manner as directed by Section Engineer in charge at site.

6

1255

7530



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.